Table of Contents
Dear customer, thank you for selecting the Elnet LTE Multimeter for
measurements of voltage, current, power, power factor and energy.
1. General specifications
Dimensions (H x W x D)
Shipping Weight
Working Conditions
Measurement Range:
Voltage
Voltage (with transformer)
Current (with transformer)
: 0 - 650 VAC
: up to 999 KV
: up to 999 KA
: 1000V
: 6A
4.
5.
7.
4.
Use the "" button until you see the message "End"
on screen and then press "Enter".
Use the " " buttons to browse among all the display
screens including display of voltage, current, power,
frequency, power factor, power measurement (Active,
Reactive, and Apparent), Active and Reactive energy
and the THD voltage and current.
2.
3. Installations
3.1. Mechanical installation:
Height
90 mm
Width
90 mm
Figure 3.1 Space in the electrical panel
9
10
11
4. MODBUS Protocol:
The ElNet LTE Energy & Power Multimeter has a serial interface
port allowing direct interface with an external communication
network supporting the MODBUS Protocol.
MODBUS is an Industry Standard, widely known and commonly
used communications protocol. Using MODBUS provides
communication between a PC and up to 247 Powermeter slaves on
a common line - the PC being the master and the powermeters the
slaves. The PC initiates the transaction (either a query or
broadcast) and the Powermeter(s) responds. Powermeters respond
to the master PCs request, but will not initiate any transmission
on its own. The PC sends a single Query transaction and the
Powermeter responds in a single response frame and is capable of
only one query and one response at a time.
4.1. MODBUS Framing
MODBUS uses the standard Remote Terminal Unit (RTU)
transmission mode. RTU mode sends data in 8-bit binary
with or without parity bit data format. For the ElNet LTE
Energy & Power Multimeter to successfully communicate,
choose 1 in the communication Set Up.
Field
No. of bits
Start bit
Data bits
Parity
Stop it
1
8
1
1
12
Function
Data
Check
8 bits
8 bits
N * 8 bits
16 bits
13
Function 16
Read holding
register
Read input
register
Preset single
register
Preset multiple
register
Action
Obtain data from
Powermeter
Obtain data from
Powermeter (Read register)
Transmit data to
Powermeter (Write single
register)
Transmit data to
Powermeter (Write multiple
register)
14
16
5. Communication Settings:
In order to connect the ElNet LTE Energy & Power Multimeter
to a PC or other device, for successful communications, both
Communication Setup parameters must match; i.e. the PC port
and the configuration settings of the Power meter, Address,
Baud Rate, Parity must match.
5.1. Communication Address:
Each Power meter in a communication system must have its
own unique address. ElNet LTE works on MODBUS
protocol, so the available addresses are - from 1 to 247.
5.2. Baud Rate:
The Baud Rate is the communication speed in Bits per second
(BPS) for communication between ElNet LTE with the PC or
other device. The better the communication line quality, the
faster the communications may be (higher Baud Rate value).
If the communication line is routed through a noisy
environment, it may be necessary to decrease the Baud Rate.
5.3. Available Baud Rates for the ElNet LTE
are: 300; 600; 1200; 2400; 9600; 19200 bps.
5.4. Parity:
The parity can be defined as ODD, NONE or
EVEN.
17
18
In order to set the Low Voltage alarm - use the " "
buttons to scroll to "AL" and press "Enter".
5. The SET ALARM screen will appear - use the " " buttons
to define the Low Voltage level for activating the alarm
and press "Enter".
6. In order to set the Phase Order alarm - use the " "
buttons to scroll to Ord and press "Enter".
7. The Phase Order alarm will appear, use the " " buttons in
order to activate\deactivate the alarm (change from No to
Yes).
Functions List:
Function
Value
Comments
Adr
Bud
0-247
300-19200
BPS
O = ODD
N = NONE
E = EVEN
Powermeter address
Setting the Baud rate
COP
8.
Parity setting
Data field is fixed = 8
bit
Start/Stop bit is fixed
= 1 bit
AL
0- 400 V
Minimum voltage to
activate the "No volt
relay".
Ord
YES = Yes
NO = NO
20