Fieldbus modules CTEU/Installation system CTEL

Fieldbus modules CTEU/Installation system CTEL


Key features

The system
 CTEU fieldbus modules for using
valve terminals
 Festo-specific interface (I-Port)
 Input modules CTSL for detecting
sensor signals
 Direct and easy networking of valve
terminals and other devices via a
bus connection

 Wide range of applications thanks


to high protection to IP65/67
 Universal connection technology
(Sub-D, M12, terminal strip)
 Optional decentralised installation
of bus node for connecting two
valve terminals
 Basic diagnostics: undervoltage,
short circuit

CTEU for the universal use of valve


terminals. The Festo-specific,
uniformly defined interface (I-Port)
enables the fieldbus modules to be
used for different types of valve
terminal.

The following protocols are currently


supported:
 CANopen
 DeviceNet
 CC-LINK
 PROFIBUS
 EtherCAT
 AS-Interface

Online via: www.festo.com

Valve terminal configurator


A valve terminal configurator is
available online to help you select a
suitable valve terminal.
Select the valve terminal with I-Port
interface and order the associated
CTEU bus nodes. The bus nodes then

only need to be placed on the valve


terminal.
The ident. code for the valve terminals
specifies the valve functions, the num
ber of valves and vacant positions, as
well as the additional functions and

Internet: www.festo.com/catalogue/...

the type of compressed air supply.


As is the case with all Festo products,
all valve terminals are supplied:
 Fully preassembled
 Equipped with fittings on request






Tested for electrical function


Tested for pneumatic function
Securely packaged
Manuals can be downloaded free of
charge

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Key features
Fieldbus systems with CTEU

CANopen
CANopen was originally developed for
the automotive industry by a joint
venture led by Bosch. It has been
maintained by the organisation CiA
(CAN in Automation) since 1995, and
at the end of 2002 it was standard
ised as European standard
EN 50325-4.

DeviceNet
DeviceNet is an open fieldbus stand
ard that was developed by Rockwell
Automation on the basis of the CAN
protocol.
DeviceNet is standardised in
European standard EN 50325.

CC-Link
Control and Communications Link
(CC-Link) was developed by Mitsubishi
Electric and has been available as an
open fieldbus network since 1999.

PROFIBUS
Process Fieldbus (PROFIBUS) is a
fieldbus that was developed by
Siemens and has been standardised
in the IEC 61158 series of interna
tional standards. It enables commu
nication between devices without the
need for any specific adaptations to
the interface.

EtherCAT
EtherCAT is a bus with real-time cap
ability; it was developed by Beckhoff
and the EtherCAT Technology Group
(ETG). EtherCAT is an open technology
and has been standardised in interna
tional standards IEC 61158 and
IEC 61784 and in ISO 15745-4.

AS-interface
AS-interface is a manufacturer-inde
pendent, easy and robust installation
system. It was developed and repres
ented by the AS-International Associ
ation, a loose association of diverse
companies from different sectors.
AS-Interface has been standardised by
IEC 62026-2 and EN 50295.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

Fieldbus modules CTEU/Installation system CTEL


Key features
Integration of the I-Port interface/IO-Link
Different bus nodes are used for
integration in the control systems of
various manufacturers.

The following protocols are supported


with the compatible bus node CTEU:
 CANopen
 DeviceNet






EtherCAT
CC-LINK
PROFIBUS
AS-Interface

A second valve terminal can be con


nected via an electrical connecting
block (decentralised adapter). (p.6)

System overview, example

PLC

Fieldbus

Node CTEU (I-Port master) on


connecting block CAPC

CPX terminal with bus node


and CTEL master
Valve terminal VTUB-12
with fieldbus node CTEU
IO-Link/I-Port

Valve terminal CPV with


I-Port interface/IO-Link
Input module CTSL

Pneumatic drive

Pneumatic drive with sensor

 Communication with higher-order


controller via fieldbus

 Use a fieldbus node CTEU com


patible with the fieldbus protocol

Internet: www.festo.com/catalogue/...

 Up to 64 inputs/outputs (solenoid
coils), depending on the valve
terminal

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Key features
System overview
Example CTEU-AS interface
Valve terminal MPA-S
with bus node CTEU-AS
Compact AS-Interface
bus node
I/O modules

VTUB-12 Valve terminal


with CTEU-AS
bus node

CPX with control block

CESA
AS-Interface
Gateway
CTSL
input module

Connecting cable NEBU

Cable socket NEFU-X


Connecting block CAPC,
decentralised installation with
bus node CTEU-AS
Connecting cable NEBU

Power supply unit SVG for


AS-Interface systems

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

Fieldbus modules CTEU/Installation system CTEL


Peripherals overview
Overview of CTEU with valve terminal VTUG
7

8
aJ

aA

6
aB

aC

aD

aE

aF
3

Accessories
1
2
3
4
5
6
7
8
9
aJ
aA
aB
aC
aD
aE
aF

Manifold rail
Connecting block
H-rail adapter
Connecting cable
Bus node
Inscription label
Power supply socket
Terminal strip
Bus connection
Fieldbus socket
Plug connector
Bus connection
Plug connector
Plug connector
Threaded sleeve
Input module

Type

Brief description

Page/Internet

VABM
CAPC
CAFM
NEBU
CTEU
ASLR
NTSD
FBSD-KL
FBA-1
FBSD-GD, NECU
FBS, NECU
FBA-2
FBS-SUB-9-BU
FBS-SUB-9-WS
UNC
CTSL-D-16E

With I-Port interface, for connecting max. 35 valves


For connecting a further terminal (2x I-Port interface)
For connecting block CAPC
For IO-Link

For bus node


For power supply
For Open Style connection
Open Style for 5-pin terminal strip
For Micro Style connection, M12, 5-pin
For Micro Style connection, M12, 5-pin
Micro Style, 2xM12, 5-pin
Sub-D
Sub-D, angled
Sub-D mounting bolts

vtug
13
13
11, 13
15, 19, 25, 29, 35, 38
aslr
18, 23, 28, 33, 37
18/23
18/23
18/23, 33
18/23, 33
18/23, 33
18/23, 33
18, 33
18, 23, 28, 33
57

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Key features Diagnostics
System diagnostics CTEU
Diagnostics LED on fieldbus node CTEU
The fieldbus-specific LEDs indicate the
communication status and the
fieldbus function.

Diagnostic messages via the fieldbus


A further LED indicates the status of
the power supply:
 Undervoltage/short circuit
 Power supply ensured
 Interruption of voltage

 Configuration error
 Short circuit/overload of an output
module

 Short circuit/undervoltage
 Undervoltage/load voltage of the
valves

Fieldbus
1

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

1 Diagnostics via fieldbus


2 Bus-specific LEDs
3 Switching status display using
one LED per valve (on the
manifold rail)
4 Additional communication and
voltage status LED for
decentralised installation
5 I-Port interface to the fieldbus
module

Fieldbus modules CTEU/Installation system CTEL


Key features Power supply
Operating voltage and load current supply
The operating voltages for the valve
manifold with I-Port interface are
centrally connected to the bus node
via a 5-pin M12 plug connector.

The operating voltages are required


for the fieldbus node electronics and
the load supply to the valves
(supplied separately from the
electronics supply).

The power supplies do not have a


common 0V line and are thus
completely galvanically isolated from
one another.

Example power supply concept CTEU with valve terminal VTUG

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Key features Power supply
Power supply concept
Example power supply concept CTEU with connecting block (decentralised adapter) CAPC and valve terminal VTUG

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

Fieldbus modules CTEU/Installation system CTEL


Technical data I-Port interface/IO-Link for valve terminal VTUG
Festo-specific, standardised interface
for direct connection to the fieldbus
by mounting the fieldbus node CTEU
or to an IO-Link master via a cable (in
IO-Link mode).

I-Port interface/IO-Link
Versions:
 I-Port interface for fieldbus nodes
(CTEU)
 IO-Link mode for direct connec
tion to a higher-order IO-Link
master

The electrical supply/transmission


of communication data takes place
via an M12 plug connector.

The following protocols are


supported:
 CANopen
 DeviceNet






CC-Link
PROFIBUS
EtherCAT
AS-Interface

General technical data


Communication types
Electrical connection

Baud rates

COM3
COM2
Intrinsic current consumption, logic supply PS
Intrinsic current consumption, valve supply PL
Max. number of solenoid coils
VAEM-L1-S-8-PT
VAEM-L1-S-16-PT
VAEM-L1-S-24-PT
Max. number of valve positions
VAEM-L1-S-8-PT
VAEM-L1-S-16-PT
VAEM-L1-S-24-PT
Ambient temperature
Degree of protection to EN 60529

[kbps]
[kbps]
[mA]
[mA]

[C]

IO-Link
 M12 plug connector, 5-pin
 A-coded
 Metal thread for screening
230.4
38.4
30
30
16
32
48
8
16
24
5 +50
IP67

LED display
Status LED X1

Colour

Status

Function

Red/green
2
3
4
5

Off
Status green
Flashing green
Flashing red/green
Static red

No 24 V logic
Everything OK
Communication error (in the I-Port or IO-Link protocol)
Load supply error (undervoltage or no load supply)
Load supply error and communication error

Pin allocation I-Port interface/IO-Link

10

Pin

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

0VVAL/OUT

Load voltage supply (valves/outputs)

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data I-Port interface/IO-Link for valve terminal VTUG
Download CAD data www.festo.com

Dimensions
Outlet on top

Outlet on the side

Type
VAEM-L1-S-

B1

Outlet on top
L1

H1

B1

Outlet on the side


L1

L2

91

47.1

25

91.5

47.1

10

Accessories I-Port interface/IO-Link


Description

Part No.

Type

Electrical interface for I-Port interface/IO-Link, outlet on top


Actuation of up to 8 double solenoid valve positions
Actuation of up to 16 double solenoid valve positions
Actuation of up to 24 double solenoid valve positions

573384
573939
573940

VAEM-L1-S-8-PT
VAEM-L1-S-16-PT
VAEM-L1-S-24-PT

Electrical interface for I-Port interface/IO-Link, outlet on the side


Actuation of up to 8 double solenoid valve positions
Actuation of up to 16 double solenoid valve positions
Actuation of up to 24 double solenoid valve positions

574207
574208
574209

VAEM-L1-S-8-PTL
VAEM-L1-S-16-PTL
VAEM-L1-S-24-PTL

Connection technology for I/O-Link


T-adapter M12, 5-pin for IO-Link and load supply

171175

FB-TA-M12-5POL

175487

SEA-M12-5GS-PG7

565306

ASLR-C-E4

574321
574322
574323

NEBU-M12G5-E-5-Q8N-M12G5
NEBU-M12G5-E-7.5-Q8N-M12G5
NEBU-M12G5-E-10-Q8N-M12G5

Straight Plug connector , for I-Port/IO-Link


Straight plug connector, M12, 5-pin
(in combination with adapter for separate load supply)
Inscription label for I-Port/IO-Link
40 pieces in frame

Connecting cable

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

11

Fieldbus modules CTEU/Installation system CTEL


Technical data Connecting block CAPC
Function
The connecting block CAPC enables
decentralised installation of fieldbus
nodes CTEU on a valve terminal or
input modules with I-Port interface.

Application
 M12 connection technology
(two interfaces)
 Enables the installation of valve
terminals or other devices over a
distance of 20 metres
 Accessory CAFM enables the
connecting block to be installed on
an H-rail

General technical data


Type

CAPC-F1-E-M12

Dimensions W x L x H
Fieldbus interface
Operating voltage range
Max. power supply
Nominal operating voltage
Product weight
Cable length

[mm]
[V DC]
[A]
[V DC]
[g]
[m]

50x148x28
2 x M12 socket, 5-pin, A-coded
18 30
2
24
85
20

Materials
Housing
Note on materials

PA reinforced
RoHS compliant

Operating and environmental conditions


Degree of protection to EN 60529
Ambient temperature
Storage temperature
Corrosion resistance class CRC
CE marking (see declaration of conformity)
1)

2)

12

[C]
[C]

IP65, IP67
5 +50
20 +70
21)
To EU EMC Directive2)

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Connecting block CAPC
Download CAD data www.festo.com
CAPC with mounted fieldbus node CTEU-CO

Dimensions
CAPC

Type

B1

B2

B3

B4

B5

D1-N-

H1

H2

H3

H4

H5

H6

L1

L2

CAPC

148

140

32

6.6

91

4.4

27.3

20.3

19.3

9.6

5.7

54.8

50

40

Pin allocation I-Port interface/IO-Link


Pin

Allocation

1
24VEL/SEN
2
24VVAL/OUT
3
0VEL/SEN
4
C/Q
5
0VVAL/OUT
Housing, FE

Description
Operating voltage supply (electronics, sensors/inputs)
Load voltage supply (valves/outputs)
Operating voltage supply (electronics, sensors/inputs)
Data communication
Load voltage supply (valves/outputs)
Functional earth

Accessory CAPC
Description

Part No.

Type

570042

CAPC-F1-E-M12

570043

CAFM-F1-H

574321

NEBU-M12G5-E-5-Q8N-M12G5

574322

NEBU-M12G5-E-7.5-Q8N-M12G5

574323

NEBU-M12G5-E-10-Q8N-M12G5

Connecting block

H-rail mounting

Connecting cable

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

13

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CO
The bus node handles communication
between the valve terminal and a
higher-order CANopen master.
The module has basic diagnostic
functions. It has 5 integrated LEDs for
on-site display. A maximum of 8 byte
inputs and 8 byte outputs are trans
mitted in the cyclic process image.

Application
Fieldbus connection
The bus connection is established
via a 9-pin Sub-D plug connector
(pin) as per the CAN in Automation
(CiA) specification DS 102 with
additional 24 V CAN transceiver
supply (option as per DS 102).

The bus connector plug (with degree


of protection IP65/IP67 from Festo
or IP20 from other manufacturers)
facilitates the connection of an in
coming and an outgoing bus cable.

There are 4 contacts each available


for the conductors (CAN_L/CAN_H
and 24 V/0 V optional) of the in
coming and outgoing bus cables.

The fieldbus parameters and the


basic device parameter settings are
set on the bus node via DIL
switches.

Max. CANopen cable length (trunk


cable):
 40 m at 1 Mbps
 100 m at 500 kbps
 250 m at 250 kbps
 500 m at 125 kbps

Max. branch cable length (drop


cable):
 0.30 m at 1 Mbps
 0.75 m at 500 kbps
 2.00 m at 250 kbps
 3.75 m at 125 kbps

The following variants can be


realised using an adapter:
 2 x Micro Style M12, degree of
protection IP65, 5-pin, socket
and pin
 Open Style plug connector,
degree of protection IP20, 5-pin,
pin

Implementation
Protocol chip used:
 CAN transceiver 82C251
Baud rates supported:
 125 kbps
 250 kbps
 500 kbps
 1 Mbps

14

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CO
General technical data
Fieldbus interface

Protocol
Baud rates
Internal cycle time
Operating voltage

[kbps]

Nominal value
Permissible range
Intrinsic current consumption at nominal operating voltage
Max. power supply
Parameterisation

[V DC]
[V DC]
[mA]
[A]

Max. address capacity, inputs


Max. address capacity, outputs
Additional functions
Operating elements
Configuration support
Device-specific diagnostics

LED display

Fieldbus-specific
Product-specific

Degree of protection to EN 60529


Note on materials
Information on housing materials
Product weight
Temperature range
Dimensions W x L x H
Corrosion resistance class CRC
CE marking
Certification
1)

2)

Environment
Storage

[g]
[C]
[C]
[mm]

 Sub-D socket, 9-pin


 Sub-D plug connector, for self-assembly
 2x M12x1, 5-pin
 5-pin terminal strip
CANopen
125, 250, 500 and 1000
1 ms per 1 byte of user data
24
18 30
Typically 65
4
Diagnostic behaviour
Fail state
8 byte
8 byte
 Emergency message
 Acyclic data access via "SDO"
DIL switches
EDS files
 System diagnostics
 Undervoltage
 Communication errors
 MNS: Network status
 IO: I/O status
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
 X2: System status of module at I-Port 2
IP65/IP67
RoHS compliant
 PC
 PA reinforced
90
5 +50
20 +70
40 x 91 x 50
21)
To EU EMC Directive2)
C-Tick

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

15

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CO
Download CAD data www.festo.com

Dimensions
CTEU-CO

Type

B1

H1

L1

CTEU-CO

91

39.8

40

Pin allocation
Pin

Allocation

Description

1
2
3
4
5
6
7
8
9
Housing

n.c.
CAN_L
CAN_GND
n.c.
CAN_SHLD
GND
CAN_H
n.c.
CAN_V+

Not connected
Received/transmitted data low
0 V CAN interface (connected to pin 6)
Not connected
Optional screened connection
0 V CAN interface, optional (connected to pin 3)
Received/transmitted data high
Not connected
24 V DC supply CAN interface
Cable screening, connection to functional earth FE

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VVAL/OUT

Load voltage supply (valves/outputs)

FE

Functional earth

Sub-D, 9-pin, CANopen interface

Power supply, M12, B-coded

16

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CO
Pin allocation of the CANopen interface
Fieldbus plug connector/adapter
Pin

Allocation

Description

FE

Functional earth

CAN_V+

24 V DC supply CAN interface

CAN_GND

0 V CAN interface

CAN_H

Received/transmitted data high

CAN_L

Received/transmitted data low

Bus connection, FBA-2-M12-5POL


2

2
3

11

Bus IN

Bus OUT

Bus connection, FBA-1-SL-5POL with FBSD-KL-2X5POL


1
CAN_GND
1

0 V CAN interface

CAN_L

Received/transmitted data low

FE

Functional earth

CAN_H

Received/transmitted data high

CAN_V+

24 V DC supply CAN interface

Connection and display components

2014/12 Subject to change

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch
Power supply for bus node and connected devices (valve terminal)
Fieldbus connection (Sub-D plug connector)

Internet: www.festo.com/catalogue/...

17

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-CO
Ordering data
Part No.

Type

CANopen bus node

570038

CTEUCO

Sub-D plug connector, straight

532219

FBS-SUB-9-BU-2x5POL-B

Sub-D plug connector, angled

533783

FBS-SUB-9-WS-CO-K

Micro Style bus connection, 2xM12, 5-pin, A-coded

525632

FBA-2-M12-5POL

Fieldbus socket for Micro Style connection, A-coded

18324

FBSD-GD-9-5POL

Plug connector for Micro Style connection, M12, 5-pin, A-coded

175380

FBS-M12-5GS-PG9

Open Style bus connection

525634

FBA-1-SL-5POL

Terminal strip for Open Style connection, 5-pin

525635

FBSD-KL-2x5POL

Threaded sleeve for Sub-D

533000

UNC4-40/M3X8

For power supply

538999

NTSDGD9M125POLRK

573767
573768
573769
573770
573771
573772

P.BE-CTEU-CO-OP+MAINT-DE
P.BE-CTEU-CO-OP+MAINT-EN
P.BE-CTEU-CO-OP+MAINT-ES
P.BE-CTEU-CO-OP+MAINT-FR
P.BE-CTEU-CO-OP+MAINT-IT
P.BE-CTEU-CO-OP+MAINT-ZH

Bus node

Bus connection

Fitting

Plug socket

Manual
Manual Bus node CTEU-CO

18

Internet: www.festo.com/catalogue/...

German
English
Spanish
French
Italian
Chinese

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-DN
The bus node handles communication
between the valve terminal and a
higher-order DeviceNet master.
The module has basic diagnostic
functions. It has 5 integrated LEDs for
on-site display. A maximum of 8 byte
inputs and 8 byte outputs
are typically transmitted in the cyclic
process image.

Application
Fieldbus connection
The bus connection is established
via a 9-pin Sub-D socket with a
typical allocation (to EN 50170).

The bus connector plug (with degree


of protection IP65/IP67 from Festo
or IP20 from other manufacturers)
facilitates the connection of an

incoming and an outgoing bus


cable.
The fieldbus parameters and the
basic device parameter settings are

set on the bus node via DIL


switches.

Max. DeviceNet cable length (trunk


cable):
 100 m at 500 kbps
 250 m at 250 kbps
 500 m at 125 kbps

Max. branch cable length (drop


cable):
 6 m at 500 kbps
 6 m at 250 kbps
 6 m at 125 kbps

The following variants can be


realised using an adapter:
 2 x Micro Style M12, degree of
protection IP65, 5-pin, socket
and pin
 Open Style plug connector,
degree of protection IP20, 5-pin,
pin

Implementation
Protocol chip used:
 CAN transceiver 82C251
Baud rates supported:
 125 kbps
 250 kbps
 500 kbps

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

19

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-DN
General technical data
Fieldbus interface

Protocol
Baud rates
Internal cycle time
Operating voltage

[kbps]

Nominal value
Permissible range
Intrinsic current consumption at nominal operating voltage
Max. power supply
Parameterisation

[V DC]
[V DC]
[mA]
[A]

Max. address capacity, inputs


Max. address capacity, outputs
Additional functions

Operating elements
Configuration support
Device-specific diagnostics

LED display

Fieldbus-specific
Product-specific

Degree of protection to EN 60529


Note on materials
Information on housing materials
Product weight
Temperature range
Dimensions W x L x H
Corrosion resistance class CRC
CE marking
Certification
1)

2)

20

Environment
Storage

[g]
[C]
[C]
[mm]

 Sub-D socket, 9-pin


 Sub-D plug connector, for self-assembly
 2x M12x1, 5-pin
 5-pin terminal strip
DeviceNet
125, 250, 500
1 ms per 1 byte of user data
24
18 30
Typically 65
4
Diagnostic behaviour
Failsafe and idle response
8 byte
8 byte
 Acyclic data access via "Explicit Message"
 Quick connect
 System status can be represented using process data
DIL switches
EDS files
 System diagnostics
 Undervoltage
 Communication errors
 MNS: Network status
 IO: I/O status
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
 X2: System status of module at I-Port 2
IP 65/IP 67
RoHS compliant
 PC
 PA reinforced
90
5 +50
20 +70
40 x 91 x 50
21)
To EU EMC Directive2)
C-Tick

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-DN
Download CAD data www.festo.com

Dimensions
CTEU-DN

Type

B1

H1

L1

CTEU-DN

40

39.8

91

Pin allocation
Pin

Allocation

Description

1
2
3
4
5
6
7
8
9
Housing

n.c.
CAN_L
CAN_GND
n.c.
CAN_SHLD
GND
CAN_H
n.c.
CAN_V+

Not connected
Received/transmitted data low
0 V CAN interface (connected to pin 6)
Not connected
Optional screened connection
0 V CAN interface, optional (connected to pin 3)
Received/transmitted data high
Not connected
24 V DC supply CAN interface
Cable screening, connection to functional earth FE

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VVAL/OUT

Load voltage supply (valves/outputs)

FE

Functional earth

Sub-D, 9-pin, DeviceNet interface

Power supply, M12, B-coded

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

21

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-DN
Pin allocation for the DeviceNet interface
Fieldbus plug connector/adapter
Pin

Allocation

Description

FE

Functional earth

CAN_V+

24 V DC supply CAN interface

CAN_GND

0 V CAN interface

CAN_H

Received/transmitted data high

CAN_L

Received/transmitted data low

Bus connection, FBA-2-M12-5POL


2

2
3

11

Bus IN

Bus OUT

Bus connection, FBA-1-SL-5POL with FBSD-KL-2X5POL


1
CAN_GND
1

0 V CAN interface

CAN_L

Received/transmitted data low

FE

Functional earth

CAN_H

Received/transmitted data high

CAN_V+

24 V DC supply CAN interface

Connection and display components

22

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch group
Power supply for bus node and connected devices (valve terminal)
Fieldbus connection (Sub-D plug connector)

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-DN
Ordering data
Part No.

Type

DeviceNet bus node

570039

CTEUDN

Sub-D plug connector, straight

532219

FBS-SUB-9-BU-2x5POL-B

Micro Style bus connection, 2xM12, 5-pin, A-coded

525632

FBA-2-M12-5POL

Fieldbus socket for Micro Style connection, M12, 5-pin

18324

FBSD-GD-9-5POL

Plug connector for Micro Style connection, M12, 5-pin

175380

FBS-M12-5GS-PG9

Open Style bus connection

525634

FBA-1-SL-5POL

Terminal strip for Open Style connection, 5-pin

525635

FBSD-KL-2x5POL

Threaded sleeve for Sub-D

533000

UNC4-40/M3X8

For power supply

538999

NTSDGD9M125POLRK

573744
573745
573746
573747
573748
573779

P.BE-CTEU-DN-OP+MAINT-EN
P.BE-CTEU-DN-OP+MAINT-EN
P.BE-CTEU-DN-OP+MAINT-ES
P.BE-CTEU-DN-OP+MAINT-FR
P.BE-CTEU-DN-OP+MAINT-IT
P.BE-CTEU-DN-OP+MAINT-ZH

Bus node

Bus connection

Fitting

Plug socket

User documentation
Manual Bus node CTEU-DN

2014/12 Subject to change

German
English
Spanish
French
Italian
Chinese

Internet: www.festo.com/catalogue/...

23

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CC
The bus node handles communication
between the valve terminal and a
higher-order master for Control &
Communication Link (CC-Link).
The module has basic diagnostic
functions. It has 5 integrated LEDs for
on-site display. A maximum of 8 byte
inputs and 8 byte outputs
are transmitted in the cyclic process
image.

Application
Fieldbus connection
The bus connection is established
by means of a screw terminal with
IP20 degree of protection, a 9-pin
Sub-D plug connector with
IP65/IP67 degree of protection from
Festo or a Sub-D plug connector
with IP20 degree of protection from
other manufacturers.

The module has a system and load


supply, a fieldbus connection and a
connection to the valve terminal
with serial I-Port interface.

Both connection types have the


function of an integrated T-distrib
utor and thus support the connec
tion of an incoming and outgoing
bus cable.

When using branch lines: maximum


branch line length 8 m, maximum 6
stations per branch line
Length of main string:
 100 m at 625 kbps, total length
of branch line 50 m
 500 m at 156 kbps, total length
of branch line 200 m
Higher baud rates not permitted
with branch line.

The following variants can be


realised using an adapter:

The integrated interface with RS485


transmission technology is designed
for the typical CC-Link 3-wire con
nection technology (in accordance
with CLPA CC-Link Spec. V1.1).

Implementation
Protocol chip used:
 MFP3 from Mitsubishi
Maximum CC-Link cable length
(minimum 0.2 m between devices):
 100 m at 10 Mbps
 150 m at 5 Mbps
 200 m at 2.5 Mbps
 600 m at 625 kbps
 1200 m at 156 kbps

24

Internet: www.festo.com/catalogue/...

 Spring-loaded terminal In/Out


with IP65 degree of protection
(adapter 532220)
 Screw-in clamping connector with
IP20 degree of protection
(adapter 197962)

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CC
General technical data
Fieldbus interface

Protocol
Baud rates
Internal cycle time
Operating voltage

[kbps]

Nominal value
Permissible range
Intrinsic current consumption at nominal operating voltage
Max. power supply
Max. address capacity, inputs
Max. address capacity, outputs
Operating elements
Device-specific diagnostics

[V DC]
[V DC]
[mA]
[A]

Additional functions
Parameterisation
LED display

Fieldbus-specific
Product-specific

Degree of protection to EN 60529


Note on materials
Information on housing materials
Temperature range
Dimensions W x L x H
Product weight
Corrosion resistance class CRC
CE marking
Certification
1)

2)

Environment
Storage

[C]
[C]
[mm]
[g]

 Sub-D socket, 9-pin


 Sub-D plug connector, for self-assembly
 Screw terminal strip, IP20
CC-Link
156 10000
1 ms per 1 byte of user data
24
18 30
Typically 70
4
16 byte
16 bytes
DIL switches
 System diagnostics
 Undervoltage
 Communication error
 System status can be displayed using process data
 Activate diagnostics
 Fail-safe and idle response
 Err: data transmission error
 Run: bus active
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
 X2: System status of module at I-Port 2
IP65/IP67
RoHS compliant
 PC
 PA reinforced
5 +50
20 +70
40 x 91 x 50
90
21)
To EU EMC Directive2)
C-Tick

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

25

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CC
Download CAD data www.festo.com

Dimensions
CTEU-CC

Type

B1

H1

L1

CTEU-CC

91

39.8

40

Pin allocation
Pin

Allocation

Description

1
2
3
4
5
6
7
8
9
Housing

n.c.
DA
DG
n.c.
n.c.
n.c.
DB
n.c.
n.c.

Not connected
Data transmission line A
Data transmission line ground (data reference potential)
Not connected
Not connected
Not connected
Data transmission line B
Not connected
Not connected
Cable screening, connection to functional earth FE

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VVAL/OUT

Load voltage supply (valves/outputs)

FE

Functional earth

Sub-D, 9-pin, CC-Link interface

Power supply, M12, AB-coded

26

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-CC-Link
Pin allocation for the CC-Link interface
Fieldbus plug connector/adapter

Pin

Description

Bus connection with terminal strip, FBA-1-KL-5POL


FE
Functional earth
SLD

Cable screening

DG

Data transmission line ground (data reference potential)

DB

Data transmission line B

DA

Data transmission line A

DA

Data transmission line A

DB

Data transmission line B

DG

Data transmission line ground (data reference potential)

n.c.

Not connected

FE

Connected to the housing of the Sub-D plug connector by means of the clamp strap

Bus connection, FBS-SUB-9-GS-24XPOL-B

Connection and display components

2014/12 Subject to change

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch
Power supply for bus node and connected devices (valve terminal)
Fieldbus connection (Sub-D plug connector)

Internet: www.festo.com/catalogue/...

27

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-CC-Link
Ordering data
Part No.

Type

CC-Link bus node

1544198

CTEUCC

Sub-D plug connector, straight

532220

FBS-SUB-9-GS-2x4POL-B

Screw terminal bus connection

197962

FBA-1-KL-5POL

Threaded sleeve for Sub-D

533000

UNC4-40/M3X8

For power supply, M12x1, 5-pin

18324

FBSDGD95POL

Bus node

Bus connection

Fitting

Plug socket

28

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-PB
The bus node handles communication
between the valve terminal and a
higher-order master for
PROFIBUS DP.
The module has basic diagnostic
functions. It has 4 integrated LEDs for
on-site display. A maximum of 8 byte
inputs and 8 byte outputs are trans
mitted in the cyclic process image.

Application
Fieldbus connection
The bus connection is established
via a 9-pin Sub-D socket with a
typical PROFIBUS allocation (to
EN 50170).

The bus connector plug (with


IP65/IP67 protection from Festo or
IP20 protection from other manu
facturers) facilitates the connection
of an incoming and an outgoing bus
cable.

An active bus terminal can be


connected using the DIL switch
integrated in the plug connector.

The Sub-D interface is designed for


controlling network components
with a fibre-optic cable connection.

Maximum fieldbus length:


 1200 m
 1200 m
 1200 m
 1000 m
 400 m
 200 m
 100 m

Maximum branch line length:


 500 m
 500 m
 100 m
 33.3 m
 20 m
 6.6 m


 RS 485 transceiver used: Analog


Devices ADM 2485
 PROFIBUS Slave Controller used:
Profichip VPC+S

Baud rates/overview of cable lengths


Baud rates supported:
 9.6 kbps
 19.2 kbps
 93.75 kbps
 187.5 kbps
 500 kbps
 1.5 Mbps
 3 Mbps - 12 Mbps

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

29

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-PB
General technical data
Fieldbus interface

Protocol
Baud rates

[kbps]
[Mbps]

Internal cycle time


Operating voltage

Nominal value
Permissible range
Intrinsic current consumption at nominal operating voltage
Max. power supply
Parameterisation

[V DC]
[V DC]
[mA]
[A]

Max. address capacity, inputs


Max. address capacity, outputs
Additional functions
Operating elements
Configuration support
Device-specific diagnostics

LED display

Fieldbus-specific
Product-specific

Degree of protection to EN 60529


Note on materials
Information on housing materials
Product weight
Temperature range
Dimensions W x L x H
Corrosion resistance class CRC
CE marking
Certification
1)

2)

30

Environment
Storage

[g]
[C]
[C]
[mm]

 Sub-D socket, 9-pin


 Sub-D plug connector, for self-assembly
 2x M12x1, 5-pin, B-coded
PROFIBUS DP
9.6, 19.2, 93.75, 187.5, 500
1.5, 12
1 ms per 1 byte of user data
24
18 30
Typically 100
2
Diagnostic behaviour
Fail-safe response
16 byte
16 byte
 System status using diagnostics program
 Emergency message
DIL switches
GSD files
 System diagnostics
 Undervoltage
 Communication errors
 BF: Bus fault
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
 X2: System status of module at I-Port 2
IP65/IP67
RoHS compliant
 PC
 PA reinforced
90
5 +50
20 +70
40 x 91 x 50
21)
To EU EMC Directive2)
C-Tick

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-PB
Download CAD data www.festo.com

Dimensions
CTEU-PB

Type

B1

H1

L1

CTEU-PB

91

39.8

40

Pin allocation
Pin

Allocation

Description

1
2
3
4
5
6
7
8
9
Housing

Screening
n.c.
RxD/TxD-P
CNTR-P
DGND
VP
n.c.
RxD/TxD-N
n.c.

Functional earth
Not connected
Received/transmitted data positive
Repeater control signal
Data ground
Supply voltage positive (+ 5 V)
Not connected
Received/transmitted data negative
Not connected
Cable screening, connection to functional earth FE

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VVAL/OUT

Load voltage supply (valves/outputs)

FE

Functional earth

Sub-D, 9-pin, PROFIBUS interface

Power supply, M12, A-coded

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

31

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-PB
Pin allocation for PROFIBUS interface
Fieldbus adapter

Pin

Bus IN

Bus OUT

n.c.

VP

RxD/TxD-N

RxD/TxD-N

n.c.

DGND

RxD/TxD-P

RxD/TxD-P

FE

Functional earth

Bus connection, FBA-2-M12-5POL-RK


2
3

2
3
5

1 1
5
4

Bus IN

4
Bus OUT

Connection and display components

32

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch
Power supply for bus node and connected devices (valve terminal)
Fieldbus connection (Sub-D plug connector)

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-PB
Ordering data
Part No.

Type

PROFIBUS bus node

570040

CTEUPB

Sub-D plug connector, straight

532216

FFBS-SUB-9-GS-DP-B

Sub-D plug connector, angled

533780

FBS-SUB-9-WS-PB-K

Bus connection M12 adapter, B-coded

533118

FBA-2-M12-5POL-RK

Straight socket, M12x1, 5-pin, for assembling a connecting cable compatible with
FBA-2-M12-5POL-RK

1067905

NECU-M-B12G5-C2-PB

Straight plug connector, M12x1, 5-pin, for assembling a connecting cable compatible
with FBA-2-M12-5POL-RK

1066354

NECU-M-S-B12G5-C2-PB

Terminating resistor, M12, B-coded for PROFIBUS

1072128

CACR-S-B12G5-220-PB

Threaded sleeve for Sub-D

533000

UNC4-40/M3X8

For power supply, M12x1, 5-pin

18324

FBSDGD95POL

575392
575393
575394
575395
575396
575397

P.BE-CTEU-PB-OP+MAINT-DE
P.BE-CTEU-PB-OP+MAINT-EN
P.BE-CTEU-PB-OP+MAINT-ES
P.BE-CTEU-PB-OP+MAINT-FR
P.BE-CTEU-PB-OP+MAINT-IT
P.BE-CTEU-PB-OP+MAINT-ZH

Bus node

Bus connection

Fitting

Plug socket

User documentation
Manual Bus node CTEU-PB

2014/12 Subject to change

German
English
Spanish
French
Italian
Chinese

Internet: www.festo.com/catalogue/...

33

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-EC
The bus node handles communication
between the valve terminal and a
higher-order master for EtherCAT.
The module has basic diagnostic
functions.
It has 6 integrated status LEDs for
on-site display.
A maximum of 16 byte inputs and
16 byte outputs are transmitted in the
cyclic process image.

Application
Fieldbus connection
The bus connection is established via
two M12 sockets, D-coded to
IEC61076-2-101 with IP65/67
degree of protection.
Both connections are equivalent
100BaseTX Ethernet ports with integ
rated auto MDI functionality (crossover and patch cables can be used)

that are brought together via an


internal switch.
The module has a system and load
supply, a fieldbus connection and a
connection to the valve terminal with
serial I-Port interface.

Please observe the applicable


specifications such as the cable
specifications for Ethernet networks
ISO/IEC11801 and ANSI/TIA/
EIA-568-B.

 Maximum cable length (between


network stations): 100 m
 Transmission rate:
100 Mbps
 EtherCAT communication chip:
ASIC ET1100

EtherCAT bus node


The EtherCAT bus node supports the
EtherCAT protocol based on the
Ethernet standard and TCP/IP
technology to IEEE802.3.
This guarantees a data exchange with
a high data transmission rate, for
example I/O data from sensors,
actuators or robot controllers, PLCs or
process equipment. Furthermore, non

34

real-time critical information such as


diagnostic information, configuration
information, etc. can be transferred.
The data bandwidth is sufficient to
transmit both data types (real-time
and non-real-time) in parallel.
The bus node has a system and load
supply, EtherCAT input and output

Internet: www.festo.com/catalogue/...

port, LEDs for status and diagnostic


messages and DIL switch elements.
Diagnostics is possible directly at the
bus node and/or via fieldbus.
The bus node has separate operating
and load voltage supplies.
The bus node is mounted on an I-Port
compatible device (e.g. valve terminal
or connecting block) from Festo.

The bus node supplies voltage to


downstream devices connected by
means of the I-Port interface.
The following can be set via DIL
switch:
 Station addresses
 Diagnostics on/off
 Fail state behaviour

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-EC
General technical data
Fieldbus interface
Protocol
Baud rates
Internal cycle time
Operating voltage (PS)

Load voltage (PL)

[Mbps]
Nominal value
Permissible range
Power failure buffering
Max.
Typical tolerance range

Max. power supply


Intrinsic current consumption at nominal operating voltage
Max. address capacity, inputs
Max. address capacity, outputs
LED display
Fieldbus-specific

[V DC]
[V DC]
[ms]
[V DC]
[V DC]
[A]
[mA]
[byte]
[byte]

Product-specific

Device-specific diagnostics

Additional functions

Configuration support
Parameterisation
Operating elements
Parameterisation via
DIL switches
Degree of protection to EN 60529
Corrosion resistance class CRC
CE marking (see declaration of conformity)
Certification
Temperature range
Operation
Storage/transport
Note on materials
Information on housing materials
Dimensions W x L x H
Product weight
1)

2)

[C]
[C]

[mm]
[g]

2x M12 socket, D-coded, 4-pin


EtherCAT
100
1 ms per 1 byte of user data
24
18 30
10
30
18 30
4
Typically 60
16
16
 Run: operating status (communication status)
 L/A2: network active (connection status) port 2 (Out)
 L/A1: network active (connection status) port 1 (In)
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
 X2: System status of module at I-Port 2
 System diagnostics
 Undervoltage
 Communication error
 Diagnostic object
 Acyclic data access via "SDO"
 Emergency message
 Modular device profile (MDP)
XML file
 Diagnostic behaviour
 Fail-safe response
DIL switches
 Fail-safe and idle response
 Diagnostics on/off
IP65
21)
To EU EMC Directive2)
C-Tick
5 +50
20 +70
RoHS compliant
 PC
 PA reinforced
40 x 91 x 50
90

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

35

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-EC
Download CAD data www.festo.com

Dimensions
CTEU-EC

Type

B1

H1

L1

CTEU-EC

91

45.3

40

Pin allocation
Pin

Allocation

Description

TX+

Transmitted data+

RX+

Received data+

TX-

Transmitted data-

RX-

Received data-

EtherCAT interface, M12, D-coded

Housing

Cable screening, connection to functional earth FE

Power supply, M12, A-coded


1

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VVAL/OUT

Load voltage supply (valves/outputs)

FE

Functional earth

Connection and display components

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch
Power supply for bus node and connected devices (valve terminal)
Fieldbus connection (Sub-D plug connector)

4
2
4

36

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-EC
Ordering data
Part No.

Type

EtherCAT bus node

572556

CTEUEC

Plug connector M12x1, 4-pin, D-coded

543109

NECU-M-S-D12G4-C2-ET

For power supply, M12x1, 5-pin

18324

FBSDGD95POL

575400
575401
575402
575403
575404
575405

P.BE-CTEU-EC-OP+MAINT-DE
P.BE-CTEU-EC-OP+MAINT-EN
P.BE-CTEU-EC-OP+MAINT-ES
P.BE-CTEU-EC-OP+MAINT-FR
P.BE-CTEU-EC-OP+MAINT-IT
P.BE-CTEU-EC-OP+MAINT-ZH

Bus node

Bus connection

Plug socket

User documentation
Manual Bus node CTEU-EC

2014/12 Subject to change

German
English
Spanish
French
Italian
Chinese

Internet: www.festo.com/catalogue/...

37

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-AS
The bus node handles communication
between the valve terminal and a
higher-order AS-Interface master.
 Activation of up to 16 solenoid coils
per valve terminal
 Automatic addressing
 Automatic detection of the number
of connected valves

Properties
The module has a system and load
supply, a bus connection and a con
nection to the valve terminal with
serial I-Port interface.

The module has basic diagnostic


functions. It has 3 integrated LEDs
for on-site display.

A maximum of 2 byte inputs and


2 byte outputs are transmitted in
the cyclic process image.

General technical data


Fieldbus interface
Protocol
Internal cycle time
Operating voltage

Nominal value
Permissible range
Intrinsic current consumption at nominal operating voltage
Max. power supply
Max. address capacity, inputs
Max. address capacity, outputs
Operating elements
Device-specific diagnostics

[ms]
[V DC]
[V DC]
[mA]
[A]

Parameterisation
LED display

Degree of protection to EN 60529


Note on materials
Information on housing materials
Temperature range
Dimensions W x L x H
Product weight
Corrosion resistance class CRC
CE marking
1)

2)

38

Bus-specific
Product-specific

Environment
Storage

[C]
[C]
[mm]
[g]

 Plug connector M12x1, 4-pin, A-coded


 Socket M12x1, 4-pin, A-coded
AS-Interface
10
30
20 31.6
Typically 50
4
2 byte
2 bytes
DIL switches
 System diagnostics
 Undervoltage
 Communication error
 Watchdog enable
 Watchdog disable
 AS-Interface operation
 PS: Operating voltage for electronics and load supply
 X1: System status of module at I-Port 1
IP65/IP67
RoHS compliant
PA reinforced
5 +50
20 +70
40 x 91 x 50
90
21)
To EU EMC Directive2)

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data CTEU-AS
Dimensions
CTEU-AS

Type

B1

H1

H2

L1

CTEU-AS

91

45.3

39.7

40

Pin allocation
Pin

Allocation

AS-Interface +

24 V load voltage supply

AS-Interface

0 V load voltage supply

AS-Interface +

24 V load voltage supply

AS-Interface

0 V load voltage supply

M12 plug connector, AS-Interface In

M12 socket, AS-Interface Out

Connection and display components

3
4

1
2
3
4

Status LED (operating status/diagnostics)


DIL switch
M12 plug connector, AS-Interface bus and auxiliary power supply (AS-Interface In)
M12 socket, AS-Interface bus and auxiliary power supply (AS-Interface Out)

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

39

Fieldbus modules CTEU/Installation system CTEL


Accessories CTEU-AS
Ordering data
Part No.

Type

572555

CTEUAS

Bus node
AS-Interface bus node

Cable socket with load voltage supply


Flat cable

4-pin socket, M12x1,


A-coded

572226

NEFU-X24F-M12G4

4-pin socket, M12x1,


A-coded

1m

572227

NEFU-X24F-1-M12G4

4-pin socket, M12x1, A-coded

572225

NEFU-X22F-M12G4

5-pin socket, M12x1, A-coded

18788

ASI-SD-FK-M12

4-pin straight socket, M12x1,


A-coded

18789

ASI-SD-PG-M12

Yellow

18940

KASI-1,5-Y-100

Black

18941

KASI-1,5-Z-100

Cable sleeve for insulating and sealing the flat cable

165593

ASI-KT-FK

Cable cap for insulating and sealing the flat cable

18787

ASI-KK-FK

Flat cable

Cable socket without load voltage supply


Flat cable

Flat cable, screw terminal

Flat cable
AS-Interface flat cable

Connecting cable

40

4-pin straight plug connector,


M12x1, A-coded

4-pin angled socket, M12x1,


A-coded

1m

185499

KM12-M12-GSWD-1-4

4-pin straight plug connector,


M12x1, A-coded

4-pin straight socket,


M12x1, A-coded

2.5 m

18684

KM12-M12-GSGD-2,5

5.0 m

18686

KM12-M12-GSGD-5

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Interface CPX-CTEL
The electrical interface CPX-CTEL
master establishes the connection to
modules of the CTEL/CTEU series that
have an I-Port interface (device). The
I/O data from the connected devices
are transmitted to the connected CPX
bus node and thus to the higher-order
controller via fieldbus.
A maximum of 4 devices can be
connected to a CPX-CTEL master via
appropriate M12 interfaces.

Application
I-Port interface
As well as transmitting the commu
nication data, the I-Port interfaces of a
CPX-CTEL master also transmit the

power supply to the connected


sensors and the load supply to the
valves (or outputs). Both circuits are

supplied separately with 24 V, using a


separate reference potential.
The connecting cables used must meet

the enhanced requirements resulting


from the dual function of signal cable
and supply cable.

Configuration example CPX-CTEL master with CTEL modules


The CPX-CTEL master provides 4
external I-Port interfaces, to each of
which a device can be connected.
I-Port is an interface for the exchan
ging of serial data for connecting
decentralised modules or valve
terminals from Festo. The I-Port
interface is based on IO-Link and is
compatible with it in certain areas.
The connection type corresponds to
a star topology. In other words, only
one module or valve terminal can be
connected to each I-Port.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

The restrictions compared to IO-Link


include:
 Permanently set baud rate of
230.4 kbps
 SIO mode is not supported
 A maximum of 32 bytes of input
data and 32 bytes of output data
 Only one dump of the master
commands is used
 Festo plug & work principle,
configuration via IODD is not
supported

41

Fieldbus modules CTEU/Installation system CTEL


Technical data Interface CPX-CTEL
Implementation
The CPX-CTEL master from Festo en
ables modules with an I-Port interface
to be connected to a CPX system:
 A maximum of 4 devices with indi
vidual electronic fuse protection
 A maximum of 64 inputs/
64 outputs per I-Port interface
 The maximum length of a string is
20 m

Configuration
Settings
The precise number of the I/O bytes
made available depends on the re
quirements of the connected devices
or of the suitable selected operating
mode.
The operating mode or preset config
uration of the CPX-CTEL master can be
specified by the user.
DIL switches are used for selecting the
operating mode and setting the
manual configuration. These DIL
switches are not required during
continuous operation and are only
accessible in the disassembled state.

The following device variants are


available:
 Input modules with 16 digital
inputs (3-pin M8 and 5-pin M12
connection technology)
 Valve terminals with I-Port interface
(up to 48 solenoid coils, different
valve functions)

The decentralised arrangement of the


modules and valve terminals with
I-Port enables them to be mounted
close to the cylinders and actuators or
sensors to be controlled. This means
that the compressed air supply lines
and sensor cables used can be
shortened, and it may be possible to
use smaller valves, thereby saving
costs.

Manual configuration

Several CPX-CTEL masters can be com


bined in one CPX terminal, depending
on the address capacity of the bus
node.
Example:
 CPX-FB13 (512 I/O)
 A maximum of 2 CPX-CTEL masters
is possible (each with 256 E/A)

Automatic configuration

In the case of manual configuration


(tool change mode), the volume of in
puts and outputs in the process image
of the CPX system or of the higherlevel fieldbus can be defined
manually using the DIL switches.

The process image then always has


the same scope, regardless of the
connected devices.
The I/O length specified always
applies to all four I-Ports (max.
8 bytes per I-Port).

In the case of automatic configura


tion, the I/O length for each I-Port is
determined individually and this
value is used to select the appropriate
or next highest configuration preset.

The power supply for the devices and


the inputs is provided by the power
supply for the electronics and sensors
of the CPX terminal.
The power supply for the outputs and
valves is provided by the power supply

for the valves of the CPX terminal.


The interlinking block with additional
power supply ensures a separate
voltage supply for the valves and out
puts. This allows the supply voltage to

be disconnected separately.
The valves and outputs of the connec
ted I-Port devices can therefore be
disconnected separately without
disconnecting the devices.

Power supply for I-Port devices


The CPX-CTEL master provides two
separate power supplies for the
connected devices:
 For operating of the device and the
inputs connected to it
 For the outputs and valves that are
connected to the device

42

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Interface CPX-CTEL
General technical data
Type
Protocol
Maximum address capacity
I-Port connection
Number of I-Port interfaces
Max. cable length
Internal cycle time
Electrical isolation

CPX-CTEL-4-M12-5POL
Outputs
Inputs

[bit]
[bit]

[m]
[ms]
Channel channel
Channel internal bus

LED displays

Diagnostics

Parameterisation

Additional functions
Operating elements
Operating voltage

Nominal value
Permissible range
Power failure buffering
Intrinsic current consumption at nominal operating voltage
Max. power supply per channel
Max. residual current of outputs per channel
Degree of protection to EN 60529
Temperature range
Operation
Storage/transport
Materials
Note on materials
Grid dimension
Dimensions (incl. interlinking block) W x L x H
Product weight

-H-

[V DC]
[V DC]
[ms]
[mA]
[A]
[A]
[C]
[C]

[mm]
[mm]
[g]

I-Port
256
256
4x socket M12, 5-pin, A-coded
4
20
1 per 8 bits of user data
No
Yes, using an intermediate supply
X1 4 = status of the I-Port interface 1 4
PS
= Electronic supply
PL
= Load supply
-P= Module error
 Communication error
 Module short circuit
 Module-oriented diagnostics
 Undervoltage
 Diagnostic behaviour
 Fail-safe mode per channel
 Forcing per channel
 Idle mode per channel
 Module parameters
 Tool change mode
Tool change mode
DIL switches
24 (polarity-safe)
18 30
10
Typically 65
4x 1.6
4x 1.6
IP65/IP67
5 +50
20 +70
PA reinforced, PC
RoHS compliant
50
50 x 107 x 55
110

Note

Please observe the general limits and


guidelines for the system when
configuring the electrical modules.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

43

Fieldbus modules CTEU/Installation system CTEL


Technical data Interface CPX-CTEL
Connection and display components
1

1 Status LEDs for I-Port interfaces


2 CPX-specific status LEDs
3 Holders for inscription labels
(IBS 6x10)
4 I-Port interfaces for up to
4 devices

Pin allocation I-Port interface/IO-Link


Pin

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

0VVAL/OUT

Load voltage supply (valves/outputs)

Download CAD data www.festo.com

Dimensions

Type
CPX-CTEL-4-M12-5POL

44

B1

B2

B3

H1

L1

108.1

118.9

124.9

55.1

50

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories Interface CPX-CTEL
Ordering data
Description

Part No.

Type

Interface for a maximum of 4 I/O modules and valve terminals with I-Port interface
(devices)

1577012

CPX-CTEL-4-M12-5POL

Cover cap

165592

ISK-M12

Inscription label holder for connection block

536593

CPX-ST-1

574321

NEBU-M12G5-E-5-Q8N-M12G5

574322

NEBU-M12G5-E-7.5-Q8N-M12G5

574323

NEBU-M12G5-E-10-Q8N-M12G5

574600
574601
574602
574603
574604
574605

P.BE-CPX-CTEL-DE
P.BE-CPX-CTEL-EN
P.BE-CPX-CTEL-ES
P.BE-CPX-CTEL-FR
P.BE-CPX-CTEL-IT
P.BE-CPX-CTEL-SV

CPX-CTEL master

Bus connection
M12

Connecting cable

User documentation
User documentation for CPX CTELMaster

2014/12 Subject to change

German
English
Spanish
French
Italian
Swedish

Internet: www.festo.com/catalogue/...

45

Fieldbus modules CTEU/Installation system CTEL


Technical data Valve terminals CPV

-M-K-P-

Flow rate
CPV10: up to 400 l/min
CPV14: up to 800 l/min

Valve width
CPV10: 10 mm
CPV14: 14 mm

Voltage
24 V DC

I-Port interface for communication


between a valve terminal CPV and an
I-Port master. It activates a valve
terminal CPV with up to 16 solenoid
coils on max. 8 valve positions.
The connection to a higher-order
controller can be achieved by:
 Connection to an I-Port master from
Festo (CPX-CTEL)
 Direct mounting of a fieldbus node
CTEU
 Connection to an IO-Link master (in
IO-Link mode)

General technical data


Protocol
IO-Link

Baud rate
Maximum number of valve positions
Nominal operating voltage
Nominal load voltage
Operating voltage range
Intrinsic current consumption
Reverse polarity protection
Diagnostics
LED display

Connection technology
Protocol
Communication mode
Port type
Number of ports
Process data width OUT
Minimum cycle time

Electronics/sensors
Load voltage
Operating voltage
Load voltage

[bit]
[ms]
[kbps]
[V DC]
[V DC]
[V DC]
[V DC]
[mA]
[mA]

Bus-specific
Product-specific

IO-Link/I-Port
5-pin
V 1.0
COM2 (38.4 kBaud), COM3 (230 kBaud)
B
1
16
3.2
38.4/230.4
8
24
24
18 30
21.6 26.4
35
700
For operating voltage
Undervoltage in load voltage supply
1 communication status
16 valve status

Materials
Cover
Note on materials

PA
RoHS compliant

Operating and environmental conditions


Mounting position
Degree of protection to EN 60529
Ambient temperature
Storage temperature
Relative air humidity
CE marking (see declaration of conformity)
1)

46

[C]
[C]
[%]

Any
IP65 (when fully plugged in or fitted with protective cover)
5 +50
20 +70
93 (non-condensing)
To EU EMC Directive1)

For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Valve terminals CPV
Connection and display components
CPV10

CPV14

1
1

1 Earthing screw

2 I-Port interface/IO-Link

Pin allocation I-Port interface/IO-Link


Pin

1 Earthing screw

2 I-Port interface/IO-Link

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

0VVAL/OUT

Load voltage supply (valves/outputs)

Download CAD data www.festo.com

Dimensions
1 I-Port interface/IO-Link

Type

B1

B2

B3

H1

H2

L1

L2

L3

CPV10-GE-PT-8
CPV14-GE-PT-8

71
89

62
78

32
32.4

38.3
38.3

26.2
26.2

110
152

101.8
142

30.2
56.5

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

47

Fieldbus modules CTEU/Installation system CTEL


Accessories Valve terminals CPV
Ordering data
Type

Device ID

Weight

Part No.

Type

CPV10

0x 000410

108.5 g

1565761

CPV10-GE-PT-8

CPV14

0x 000510

200 g

1564984

CPV14-GE-PT-8

171175

FB-TA-M12-5POL

Straight plug connector M12, 5-pin (for T-adapter)

175487

SEA-M12-5GS-PG7

574321

NEBU-M12G5-E-5-Q8N-M12G5

574322

NEBU-M12G5-E-7.5-Q8N-M12G5

574323

NEBU-M12G5-E-10-Q8N-M12G5

I-Port bus node


Bus node with I-Port interface/IO-Link
and 8 valve positions
(maximum 8 double solenoid valves)

Connection technology for IO-Link


T-adapter M12, 5-pin for IO-Link and load voltage supply

Connecting cable

48

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Valve terminals MPA-L

-M-

-K-

-P-

Flow rate
VMPA1:
VMPA14:
VMPA2:

up to 360 l/min
up to 670 l/min
up to 700 l/min

Valve width
VMPA1:
VMPA14:
VMPA2:

10 mm
14 mm
20 mm

Voltage
24 V DC

I-Port interface for communication


between a valve terminal MPA-L and
an I-Port master. It activates a valve
terminal MPA-L with up to 32 solenoid
coils on max. 32 valve positions.
The connection to a higher-order
controller can be achieved by:
 Connection to an I-Port master from
Festo (CPX-CTEL)
 Direct mounting of a fieldbus node
CTEU
 Connection to an IO-Link master (in
IO-Link mode)

General technical data


Protocol
IO-Link

Baud rate
Operating pressure
Pilot pressure
Nominal operating voltage
Intrinsic current consumption

Connection technology
Protocol
Communication mode
Port type
Number of ports
Process data width OUT
Minimum cycle time

Operating voltage
Load voltage

[bit]
[ms]
[kbps]
[bar]
[bar]
[V DC]
[mA]
[mA]

Reverse polarity protection


Diagnostics
LED display

IO-Link/I-Port
5-pin
V 1.0
COM2 (38.4 kBaud), COM3 (230 kBaud)
B
1
8 32
3.2
38.4/230.4
0.9 10
38
24
30
30
For operating voltage
Undervoltage in load voltage supply
1 communication status

Materials
End plate
Note on materials

PPA reinforced
RoHS compliant

Operating and environmental conditions


Mounting position
Ambient temperature
Storage temperature
Corrosion resistance class CRC1)
1)

[C]
[C]

Any
5 +50
20 +40
3

Corrosion resistance class 3 according to Festo standard 940 070


Components subject to high corrosion stress. Externally visible parts with primarily functional surface requirements which are in direct contact with the surrounding industrial environment or
media such as solvents and cleaning agents.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

49

Fieldbus modules CTEU/Installation system CTEL


Technical data Valve terminals MPA-L
Connection and display components
VMPAL-EPL-IPO32

2
1 Status LED

2 Earthing screw

Pin allocation I-Port interface/IO-Link


Pin

3 I-Port interface/IO-Link

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

24VVAL/OUT

Load voltage supply (valves/outputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

0VVAL/OUT

Load voltage supply (valves/outputs)

Download CAD data www.festo.com

Dimensions

1 I-Port interface/IO-Link
Type
VMPAL-EPL-IPO32

50

B1

B2

B3

B4

B5

B6

D1

D2

H1

L1

L2

L3

L4

L5

L6

L7

64.8

34.5

5.7

6.2

6.4

4.5

41.8

110

107

66.3

33.5

65

23.5

26

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories Valve terminals MPA-L
Ordering data
Device ID

Weight

Part No.

Type

170 g

575667

VMPAL-EPL-IPO32

171175

FB-TA-M12-5POL

Straight plug connector M12, 5-pin (for T-adapter)

175487

SEA-M12-5GS-PG7

574321
574322
574323

NEBU-M12G5-E-5-Q8N-M12G5
NEBU-M12G5-E-7.5-Q8N-M12G5
NEBU-M12G5-E-10-Q8N-M12G5

I-Port bus node


Bus node with I-Port interface/IO-Link and up to 32
0x 000620
valve positions (maximum 16 double solenoid valves)

Connection technology for IO-Link


T-adapter M12, 5-pin for IO-Link and load voltage supply

Connecting cable

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

51

Fieldbus modules CTEU/Installation system CTEL


Technical data Input modules CTSL
Function
Digital input modules facilitate the
connection of proximity sensors or
other 24 V DC sensors (inductive,
capacitive, etc.).
Plug connectors with double alloca
tion are separated using a DUO plug
connector or DUO cable.

Application
 Input modules for 24 V DC sensor
signals
 M12 connection technology
 Display of the input statuses for
each input signal via an assigned
LED
 Operating voltage supply 24 V DC
for all connected sensors
 Diagnostic LED for short circuit/
overload of sensor supply
 Labelling options on all sides with
large, hinged inscription label
 Earthing plate and H-rail mounting
already integrated

General technical data


Type
Electrical connection
Protocol
IO-Link

CTSL-D-16E-M8-3

Connection technology
Protocol
Communication mode
Port type
Number of ports
Process data width OUT
Minimum cycle time
Device ID

Baud rate
Max. no. of inputs
Nominal operating voltage
Operating voltage range
Current consumption at nominal operating voltage of logic circuit
Max. residual current per module
Reverse polarity protection
Fuse protection (short circuit)
Electrical isolation between channels
Switching level
Signal 0
Signal 1
Input debounce time
Certification
Switching logic at inputs
LED display
Bus-specific
Product-specific

52

[bit]
[ms]
[ms]
[kbps]
[V DC]
[V DC]
[mA]
[mA]

[V]
[V]
[ms]

Internet: www.festo.com/catalogue/...

CTSL-D-16E-M12-5

16x socket M8, 3-pin


8x socket M12, 5-pin
IO-Link/I-Port
5-pin
V 1.0
COM2 (38.4 kBaud), COM3 (230 kBaud)
B
1
16
3.2
0x 700410
38.4/230.4
16
24
18 30
Max. 35
1.2
For operating voltage
Internal electronic fuse protection for each group
No
5
11
0.5 (3 ms, 10 ms, 20 ms parameterisable)
IEC1131-T2
PNP (positive switching)
X20: I-Port/IO-Link
1 operating voltage
16 channel status
2 group diagnostics

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Input modules CTSL
Materials
Housing
Cover
Note on materials
Product weight
Dimensions

(W x L x H)

[g]
[mm]

PA reinforced
PA reinforced
RoHS compliant
250
143 x 103 x 32

Operating and environmental conditions


Type of mounting
Degree of protection to EN 60529
Ambient temperature
Storage temperature
Corrosion resistance class CRC1)
CE marking (see declaration of conformity)
Approval certificate
1)

2)

[C]
[C]

Either via H-rail or via through-hole


IP65/IP67 (when fully plugged in or fitted with protective cap)
5 +50
20 +70
21)
To EU EMC Directive2)
C-Tick

Corrosion resistance class 2 according to Festo standard 940 070


Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or
media such as coolants or lubricating agents.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

53

Fieldbus modules CTEU/Installation system CTEL


Technical data Input modules CTSL
Connection and display components
CTSL-D-16E-M8-3
4

3
2

1
2
3
4
5
7

Pin allocation I-Port interface/IO-Link


Pin

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

Pin allocation Sensor connections CTSL-D-16E-M8-3


Pin allocation

54

Earth terminal
I-Port interface/IO-Link
Status LED for power supply (PS)
Status LED for I-Port (X20)
Status-LEDs for inputs (status
display, green)

6 Status LED (group) for short


circuit/overload of sensor
supply (red)
7 Fixture for inscription label
holder ASCF-H-E2
8 Sensor connections
(1 input per socket)

Pin

Allocation

Description

24V

Operating voltage 24 V

0V

Operating voltage 0 V

Ix*

Sensor signal

Ix = Input x

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Technical data Input modules CTSL
Connection and display components
CTSL-D-16E-M12-5
4

7
8

1
2
3
4
5
7

Pin allocation I-Port interface/IO-Link


Pin

Allocation

Description

24VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

0VEL/SEN

Operating voltage supply (electronics, sensors/inputs)

C/Q

Data communication

Pin allocation Sensor connections CTSL-D-16E-M12-5


Pin allocation

Earth terminal
I-Port interface/IO-Link
Status LED for power supply (PS)
Status LED for I-Port (X20)
Status-LEDs for inputs (status
display, green)

6 Status LED (group) for short


circuit/overload of sensor
supply (red)
7 Fixture for inscription label
holder ASCF-H-E2
8 Sensor connections
(2 inputs per socket)

Pin

Allocation

Description

24V

Operating voltage 24 V

Ix+1*

Sensor signal

0V

Operating voltage 0 V

Ix*

Sensor signal

FE

Functional earth

Ix = Input x

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

55

Fieldbus modules CTEU/Installation system CTEL


Technical data Input modules CTSL
Download CAD data www.festo.com

Dimensions
CTSL-D-16E-M8-3

CTSL-D-16E-M12-5

Type

B1

B2

B3

B4

B5

D1

D2

H1

H2

L1

L2

L3

T1

CTSL-D-16E

103

87

35.5

32.8

4.3

32

9.4

143

127

3.5

56

Internet: www.festo.com/catalogue/...

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Accessories Input modules CTSL
Ordering data
Description

Part No.

Type

16 sensor connections M8, 3-pin, single allocation

1387363

CTSL-D-16E-M8-3

8 sensor connections M12, 5-pin, double allocation

1387359

CTSL-D-16E-M12-5

5-pin, PG7
4-pin, PG7
4-pin, 2.5 mm2 O.D.
3-pin, solderable
3-pin, screw-in
4-pin

175487
18666
192008
18696
192009
18779

SEA-M12-5GS-PG7
SEA-GS-7
SEA-4GS-7-2,5
SEA-GS-M8
SEA-3GS-M8-S
SEA-GS-11-DUO

Input modules

Plug connector
Straight plug connector, M12

Straight plug connector, M8


Plug connector for 2 cables, M12, PG11

5-pin

192010

SEA-5GS-11-DUO

Push-in T-connector

2x socket, M12, 5-pin


1x plug connector M12,
4-pin

541596

NEDU-M12D5-M12T4

DUO cable, 1x straight plug connector M12

2x straight socket M8
1x straight socket M8 and
1x angled socket M8
2x angled socket M8
2.5 m
5.0 m
0.5 m
1m
2.5 m
5m

18685
18688

KM12-DUO-M8-GDGD
KM12-DUO-M8-GDWD

18687
539052
539052
539052
539052
539052
539052

KM12-DUO-M8-WDWD
NEBU-M12G4-K-2.5-M12G4 1
NEBU-M12G4-K-5-M12G4 1
NEBU-M8G3-K-0.5-M8G31
NEBU-M8G3-K-1-M8G3 1
NEBU-M8G3-K-2.5-M8G31
NEBU-M8G3-K-5-M8G3 1

574321

NEBU-M12G5-E-5-Q8N-M12G5

574322

NEBU-M12G5-E-7.5-Q8N-M12G5

574323

NEBU-M12G5-E-10-Q8N-M12G5

547473

ASCF-H-E2

Connecting cables

Connecting cable, M12, 4-pin, straight plug


connector-straight socket
Connecting cable, M8, 3-pin, straight plug connectorstraight socket

Inscription label holder


Inscription label holders for EL modules, bag of 10

1)

Modular product, more information Internet: nebu

2014/12 Subject to change

Internet: www.festo.com/catalogue/...

57

Fieldbus modules CTEU/Installation system CTEL


Example of a valve terminal VTUG with I-Port interface
Download CAD data www.festo.com

Dimensions Example of a valve terminal with I-Port interface,


size 10

1 Ports 1, 3 and 5: Gx (at both


ends)
3 Ports 12/14: M5 (at both ends)
4 Ports 82/84: M5 (at both ends)

58

5 CTEU CANopen
6 For mounting valves/blanking
plates/supply plates on
manifold block: M2

Internet: www.festo.com/catalogue/...

7 Blanking plate
8 Supply plate, ports 1, 3 and 5:
M7

9 H-rail mounting
aJ Inscription label holder

Subject to change 2014/12

Fieldbus modules CTEU/Installation system CTEL


Example of a valve terminal VTUG with I-Port interface
Type
VABM
Type

No. of
valve positions

B1

B2

B3

B4

B5

B6

B7

B8

Size 10
D1

4-24

91.5

54

52.4

41.5

25.6

9.8

16

17.7

4.5

No. of
valve positions H9

H11

H12

L4

5.5

54.8

4.8

10.5

Size 10
L5

H3

H4

H5

H6

H7

H8

67

56.1

54.1

15.2

11.5

15.5

L6

L7

L8

L9

L10

2.5

4.5

36

20

42.5

4-24

Type

No. of
valve positions

L1

Size 10
L2

L3

4
5
6
7
8
9
10
12
16
20
24

103
113.5
124
134.5
145
155.5
166
187
229
271
313

94
104.5
115
125.5
136
146.5
157
178
220
262
304

31.5
42
52.5
63
73.5
84
94.5
115.5
157.5
199.5
241.5

2014/12 Subject to change

57.3

H2

VABM

VABM

12.4

H10

H1

102.3 77.1

Internet: www.festo.com/catalogue/...

59