Whole Body Counting Systems
Whole Body Counting Systems
Whole Body Counting Systems
Low-Background Room
NaI System with Single, Large Crystal
in Collimated Shield and Swivel Seat.
ACTINIDE-85 Detector
Lung Burden measurements are made with an array of large diameter, low
background detectors such as our unique ACTINIDE-85 assemblies.
ACTINIDE-85 is a high-resolution, high-purity germanium detector designed specifically for lung
burden and whole-body counting applications. The unique detector design allows for the
detection of small amounts of actinides such as uranium, plutonium, and americium, as well as
higher energy fission products and naturally-occurring radioisotopes, in a distributed source
such as the human lung. The detector is based on the PROFILE GEM-FX8530 detector, which
employs a proprietary thin entrance window in order to improve low energy efficiency. The
ACTINIDE-85 has been optimized to provide high detection efficiency and resolution
performance in the energy range of actinides such as Pu, Am and U, which span the
13200 keV energy range, while the excellent warranted energy resolution at 1.33 MeV
means that the ACTINIDE-85 is equally well suited for analysis of fission products as well. It is
therefore ideal for monitoring radiation workers for lung burden, body burden and wounds.
85-mm diameter and 30-mm thick high-purity germanium (HPGe) detector optimized for
Actinide Bioassay measurements.
5400 mm2 frontal active area with excellent photon sensitivity for photon energies above
10keV.
Warranted Energy Resolution (FWHM) equal to or better than 600 eV at 14.4 keV.
Warranted Energy Resolution (FWHM) equal to or better than 50 eV at 122 keV.
Warranted Energy Resolution (FWHM) equal to or better than 1.9 keV at 1332 keV.
Warranted P:C ratio >55:1.
FW0.1M/FWHM typically <2.0, FW0.2M/FWHM typically <2.9.
Available in LN2-free mechanically cooled configurations.
The all carbon fiber endcap is ideal for high transmission of low energy photons and
exceptional low-background performance. The large diameter (85 mm) gives greater
geometric efficiency than any comparable detector system, as much as 13% more per
detector in fact. Higher efficiency means shorter count times to achieve the same Minimum
Detectable Activity.
Description
StandFAST II
WBC-200
WBC-200-2
WBC-200-DFX8530
High Resolution HPGe Based Chair with two detectors and LN2 free cooling
WBC-BSCAN
High Resolution HPGe Based Scanning Bed with one detector and LN2 free cooling
WBC-T
NaI Based Counter Top Thyroid Screening System with one detector
WBC-LB-2
High Resolution HPGe Based Lung Burden Analysis System with two detectors
WBC-LB-4
High Resolution HPGe Based Lung Burden Analysis System with four detectors
For over 25 years, ORTEC has supplied and continues to supply a wide variety of Bio-Assay products world-wide: complete
systems, upgrades, support and training. We are committed to supplying high performance, innovative and reliable solutions
to all aspects of whole-body counting and would be happy to discuss your requirements in detail. In the first instance, please
contact your local ORTEC Representative.