Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MCS350S 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

TECHNICAL DATA

DIESEL GENERATING SET

MPMC POWERTECH CORP.

MC Series

50HZ
MCS350S-1 / MCS350-1

MC Series
MCS350S-1 / MCS350-1
Features

Reference images, the actual shall prevail

Compact structure with high-strength chassis;


Easy operation and maintenance, Low cost;
Excellent performance damping system;
Compliance with international electrical safety standards of

electrical system;
8 hours base tank;
High-performance maintenance-free batteries with isolation

switch
50Radiator;
Top lifting, Forklift bottom hole design, easy to transport;
Industrial muffler;
Noise reduction structureLow noise;
Convenient power output interface;
IP56 (control system)
Customized design for user
Structure optional: Open (MCS350-1)

Sound-proofMCS350S-1

Genset Technical Data

Dimension and Weight

Output frequency

50 HZ

Rated speed

1500 rpm

Prime power

350 KVA

Standby power

385 KVA

Rated voltage

400 V

Phase

Noise dB(A) @7m

70

Engine model

NTA855-G2A

Alternator model

HCI 444E

Generating set model

MCS350S-1

MCS350-1

Fuel consumption of 100% load

71.9 Litres/h

Length(L)

(mm)

4300

3366

Fuel consumption of 75% load

54.9 Litres/h

Width(W) (mm)

1422

1045

Voltage regulation rate

1%

Height(H) (mm)

2210

1804

Random voltage variation

1%

Dry weight

(k g)

3821

2935

Frequency regulation rate

5%

Tank capacity

(L)

900

710

Random frequency variation

0.5%

Page: 1/7

MC Series
Engine Specifications
Engine model

NTA855-G2A

Engine manufacturer

Cummins

Number of cylinders

Cylinder arrangement

In-line

Cycle

Four stroke

Aspiration

turbo-charged & after-cooled

Bore

140
x 152
Air-air
after-cooled,

Stroke (mm mm)

Displacement (Liter)

14

Compression Ratio

Air-air after-cooled,
14.0:1

Prime power/speed (kW/RPM)

Air-air
after-cooled,
310
/1500rpm

Standby power/speed (kW/RPM)

343 /1500rpm

Speed governor

Air-air
Electricalafter-cooled,

Cooling system

Forced Water Cooling Cycle

Steady speed droop (%)

1%

Total lubrication system capacity


Coolant capacity

(L)

(L)

Fuel consumption at 100% load

38.6
20.8

(g/kWh)

192.6 (at 1500RPM)

Starter motor

DC24V

Alternator

DC24V

Alternator Specifications
Rated frequency

50 Hz

Rated speed

1500 rpm

Alternator model

HCI 444E

Rated output prime power

350kVA

Efficiency (%)

93.5%

Phase

Rated voltage

400 V

Exciter type

Self excitation, Brushless

Power factor

0.8

Voltage adjust range

5.0%

Voltage regulation NL-FL

1.0%

Insulation grade

Protection grade

IP23

Xd DIR. AXIS SYNCHRONOUS

2.71

X'd DIR. AXIS TRANSIENT

0.18

X''d DIR. AXIS SUBTRANSIENT

0.13

Xq QUAD. AXIS REACTANCE

2.33

X''q QUAD. AXIS SUBTRANSIENT

0.32

Optional
Optional Alternator brand

Leroy Somer

Mecc alte

MPMC

Optional Alternator model

LSA 47.2 VS1

ECO38-3LN/4

LYG 314D

Exciter type

Self-excited

Self-excited

Self-excited

Rated output prime power

350KVA

350KVA

350KVA
Page: 2/7

MC Series

Control System
NSM-800-3110 (Standard)
All MPMC Gensets have a control cubicle (the Deepsea control module DSE3110 as standard) mounted on
isolated support

Main Features
Manual and automatic mode
Parameter configuration via RS-232 serial communication
Remote control automatic start/shutdown
Optional ECU control
Optional CAN engines
Optional speed sensor access
PLC programming
Operating temperature: -20to 70
IP56 Rating
Back-lit icon LCD display
Power Save mode
CAN and Magnetic Pick-up/Alt. versions available (specify on
ordering)
PC configurable
6 Digital inputs

Protecting Functions

4 Outputs (2 configurable on Magnetic Pick up/Alt., 4 configurable


on CAN version)

The control module display

Over frequency / under frequency


Over voltage / under voltage
Over current

Generator voltage

Over speed /under speed

Generator frequency

Emergency stop

Battery voltage

Low oil pressure

Engine speed

High water temperature

Load current

Failure to start/Failure to stop

Engine run-time Hours

Battery charger failure

Engine oil pressure (Panel Meter)

Comprehensive shutdown or warning on fault

Engine coolant temperature (Panel Meter)

condition

Page: 3/7

MC Series

Control System
NSM-800-7320 (Optional)
NSM-100-7320 is an advanced control module based on micro-processor, It is an Auto Mains (Utility) Failure Control
Module(AMF), have been designed to start and stop generating sets that include electronic And non-electronic
engines. Include the additional capability of being able to monitor a mains (utility) supply. when main is not
availableIt can automatically start the engine and close generating sets breaker automatically, Accurately measure
various operational parameters and display all values and alarms information on the LCD. In additional, it can
automatically open breaker, and shutdown the engine after the main supply recovers.

Main Features
AMF and ATS and communication and expansion function
Designed to work with electronic or non-electronic or gas

engine simultaneously. (support many kinds of engines


ECU).
Manual, Automatic, Test and remote control mode

selectable.
Monitoring and measuring operational parameters of the

mains supply and genset.


Indicating

operation

status,

fault

conditions,

all

parameters and alarms


Multiple protections and multiple parameters display.
Includes 12 inputs and eight outputs. 8 inputs are

configurable and 4 outputs are configurable.


Can be programmed using the front panel or by using the

PC software.
Support twelve languages. The language was edited by

customer.
Graded protection: pre-alarm, shutdown and electrical

trip, flexible setting.


The module can be pre-set for four operating modes and

The control module display


Generator voltage
Generator frequency
Battery voltage
Engine speed
Load current
Generator KVA, KW, PF

protecting parameters.

Engine run-time Hours

Add DSE860 or DSE865 module, internet network

Engine oil pressure

monitoring can be realized.

Engine coolant temperature

The firmware can be updated automatically, so customer

Real time clock for time and date, overall

can have the latest version.

runtime

Page: 4/7

MC Series

Optional
Engine

Alternator

Generator Set

Water Jacket Preheater


Fuel-water separator
Oil pump
Oil preheater
Battery preheater

PMG excitation

Tools with the machine

Space heater

Coolant (-30C)

Control System

Fuel System

Canopy

AMF function
ATS control cabinet
Double-frequency and double voltage
Single phase
ABB MCCB

12 / 24 hour base tank (single wall)


Dual wall base fuel tank
Outside fuel tank
Automatic fuel feeding
Fuel level indicate

Hired type

Winding Temperature Measuring

Economy Oil heater


Trailer

Page: 5/7

MC Series

Contact Us
MPMC POWERTECH CORP.
Add:No.111 Luda Rd., Luyuan Industrial Zone, Pudong Shanghai China
Tel: +86 21 60970158 Fax: +86 21 60970155
Mobile: +86-18621857018 (Robert)
E m a i l : sales@mpmc-china.com
Web site : www.mpmc-china.com

DISTRIBUTED BY:
MPMC reserves the right to make changes in model,
technical specification, color, configuration and accessories
without prior notice.
Please contact the salesman before ordering.

C 2013 by MPMC, All right reserved.

Page: 6/7