INTRODUCTION
Check the integrity of the device after removing it from the packing.
General characteristics
- timed operation
- automatic extension of time during conversation
- automatic shut-OFF of system at the end of a conversation (by
replacing the hand-set)
- the possibility by every monitor to control one or more video entrances
- audio and video privacy between monitors
- switching ON of monitors one at a time
- the possibility to connect more monitors and intercoms in each flat
- the possibility to communicate privately among other monitors and
intercoms
- priority of video/audio connection on an outside call without the
possibility of switching on by other monitors at the same time
- power supply electronically protected against short circuits and
overloading.
CE MARK
The CE mark ensures that the product complies with the requirements of the
European Community Directives in force; in particular, Electrical Safety LVD73/23,
Electromagnetic Compatibility EMC89/336 and Telecommunication Terminals
R&TTE99/5 Directives.
As set forth by the Directives, the technical documentation and Conformity Declarations are available in the Companys offices for verifications and controls by
competent Authorities.
TECHNICAL MANUAL
Edition 2002
VIDEO-INTERCOM SYSTEM
Page
INDEX
Project monitors series
PuntoVirgola monitors series
Intercoms
Mody push-button panels
ErreP/R push-button panels
Power supply and control unit
Service modules
Video memory
Installation instructions
Working instructions
Troubleshooting
2
8
11
12
21
23
24
25
26
28
29
30
Mody Videokit
Si 5000M One-way videokit with application of multipolar cable art.1304
31
31
32
33
35
37
39
41
43
45
55
55
58
59
60
60
Installation diagrams
Si 411R/1 One-way video-intercom system
Si 41MR/2 Multi-way combined intercom and video-intercom system
Si 42MR/1 Multi-way video-intercom system with two automatically switched entrances, one of which is only audio
Si 42MR/2 Multi-way video-intercom system with two automatically switched video entrances
61
61
62
63
64
Product list
65
48
49
50
54
WITHOUT COAX
*
WITH COAX
1
(9GB-2002)
47
MODY
MONITORS
Project series
ERREP/R
89
3 1/2"
PROJECT
215
8 7/16"
PUNTOVIRGOLA
*
SLIM
PT5160. Two-colour flat tube monitor with audiovideo privacy, electronic microphone, differentiated double electronic ringing sounds (modulated
and continuous note) and terminal board for the
connection to the wall-bracket. With two buttons,
one for control switch ON and one for door lock
release, and 6 supplementary buttons, that can be
added for additional services such as: control
switch ON, intercommunicating calls, stair lights,
door lock release, etc.
The buttons are included in the kit of the monitor.
The maximum acceptable current to the button
terminals is 60mA. For higher currents use relay
unit art.1471. It can be installed on the wall (with no
built-in) by using the wall-bracket WB5100 or
WB5160. For particular needs it is possible to
separate the common of the buttons labelled P4,
P5 and P6 by cutting the W1 jumper on the wallbracket. The buttons have the 2C terminal in
common. In this case the maximum acceptable
current to the three buttons is 0.5A.
Terminals
1 Video signal input 0.81.5Vpp
2 General ground
3 Video ground
4 Control switch ON - button
8 Positive power supply output for video
floor distributors 12Vdc
9 Door lock release - button
10 Call from the door station (180mA)
11 Audio ground
12 Microphone output
13 Speaker and automatic cancel
14 Positive power supply input 1824Vdc
V Not connected
83.5
3 5/16"
WITHOUT COAX
1824Vdc
0.35A
4" FLAT CRT
625 lines
15625Hz
50Hz
>5MHz
0.81.5Vpp
24 sec.
0+50C
90%RH
U
P
40.5
1 5/ "
122
4 13/16"
140 150 cm
4" 7" 4" 11"
aaaaaaaaaaaa
Supplementary push-buttons installation
WITH COAX
Technical data
Power Supply
Operating current
Screen
Television standard
Horizontal frequency
Vertical frequency
Bandwidth
Video signal on 75
Starting up time
Operating temperature
Max. permissible humidity
Terminals
The terminals from 1 to 14 have the same functions and characteristics as the previous model.
43
1 11/16"
WB5160. The wall bracket includes 2 terminal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommunicating service (position A).
By using the PT5160, PT5160W and
PT5160W-LCD monitors with multi-way systems without the intercommunicating service,
the audio privacy can be restored by positioning the jumper J1 in B.
1824Vdc
0.4A
4" LCD
PAL
15625Hz
50Hz
>5MHz
0.81.5Vpp
1 sec.
0+50C
90%RH
2
(9GB-2002)
MODY
MONITORS
Project series
ERREP/R
U
P
PROJECT
*
PUNTOVIRGOLA
U
P
SLIM
WB 5160
TA 5160
J2
U
P
X1 X2 2C 1C P1 P2 P3 P4 P5 P6
J3
1
3
1
2 4 8 9 10 11 12 13 14 V
W1
1 2 3
75
J1
1 2 3
J1
B
Plugging in of monitor connectors to the terminal
boards of wall bracket.
1 2 3
J1
WITHOUT COAX
Mounting instruction
Make the connection of the cable to
the terminals of the table adapter.
Make the connection of the conductors of the system to the junction box.
Plug-in the 2 flat cable to the table
adapter.
Fasten the monitor to the table
adapter.
3
(9GB-2002)
WITH COAX
Junction box.
MODY
MONITORS
Project series
ERREP/R
8 1/2"
54
2 1/8"
113
4 7/16"
PROJECT
233
9 3/16"
PUNTOVIRGOLA
*
SLIM
PT5660W. White colour monitor with traditional cathode tube with audio-video privacy,
electronic microphone, differentiated double
electronic ringing sounds (modulated and
continuous note) and terminal board for the
connection to the wall-bracket. With two buttons, one for control switch ON and one for
door lock release, and 6 supplementary buttons, that can be added for additional services such as: control switch ON, intercommunicating calls, stair lights, door lock release,
etc. The buttons are included in the kit of the
monitor. The maximum acceptable current to
the button terminals is 60mA. For higher
currents use relay unit art.1471.
It can be installed on the wall by using the
wall-bracket art.WB5600 or WB5660 and the
back-box art. 1283. For particular needs it is
possible to separate the common of the buttons labelled P4, P5 and P6 by cutting the W1
jumper on the wall-bracket. The buttons have
the 2C terminal in common. In this case the
maximum acceptable current to the three
buttons is 0.5A.
WITHOUT COAX
Technical data
Power Supply
Operating current
Video tube
Television standard
Horizontal frequency
Vertical frequency
Bandwidth
Video signal on 75
Starting up time
Operating temperature
Max. permissible humidity
Terminals
1 Video signal input 0.81.5Vpp
2 General ground
3 Video ground
4 Control switch ON - button
8 Positive power supply output for video
floor distributors 12Vdc
9 Door lock release - button
10 Call from the door station (180mA)
11 Audio ground
12 Microphone output
13 Speaker and automatic cancel
14 Positive power supply input 1824Vdc
V Not connected
WB5660. The wall bracket includes 2 terminal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommunicating service (position A).
By using the PT5660W monitors with multiway systems without the intercommunicating
service, the audio privacy can be restored by
positioning the jumper J1 in B.
Terminals
The terminals from 1 to 14 have the same functions and characteristics as the previous model.
V Activation input for digital systems
X1 AC power supply input 13Vac-0.35A
X2 Intercommunicating call input (ground command)
1C Common for P1, P2 and P3 buttons
2C Common for P4, P5 and P6 buttons
P1P6 Service buttons - max 60mA
U
P
1824Vdc
0.6A
4.5" - 90
625 lines
15625Hz
50Hz
>5MHz
0.81.5Vpp
57 sec.
0+50C
90%RH
J3
J2
*
U
P
WITH COAX
4
(9GB-2002)
MODY
MONITORS
Project series
PROJECT
*
126
415/16"
PUNTOVIRGOLA
60
2 3/8 "
175
6 7/8 "
ERREP/R
SLIM
140 150 cm
4 7"
4 11"
aaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaa
Dismounting of monitor from the wall
bracket.
J3
X1
X2
2C
1C
P1
P2
P3
P4
P5
P6
2
4
8
9
10
11
12
13
14
V
J1
1 2 3
J1
B
J2
W1
1 2 3
J1
1 2 3
WITHOUT COAX
R1
75
5
(9GB-2002)
WITH COAX
WB 5660
Inserting of extra buttons.
MODY
MONITORS
Project series
ERREP/R
8 1/2"
113
4 7/16"
PROJECT
233
9 3/16"
PUNTOVIRGOLA
*
SLIM
PT5860. Two-colour reflex monitor with audio-video privacy, electronic microphone, differentiated double electronic ringing sounds
(modulated and continuous note) and terminal board for the connection to the wallbracket. With two buttons, one for control
switch ON and one for door lock release, and
6 supplementary buttons, that can be added
for additional services such as: control switch
ON, intercommunicating calls, stair lights,
door lock release, etc. The buttons are included in the kit of the monitor. The maximum
acceptable current to the button terminals is
60mA. For higher currents use relay unit
art.1471.
It can be installed on the wall by using the
wall-bracket art.WB5600 or WB5660. For
particular needs it is possible to separate the
common of the buttons labeled P4, P5 and P6
by cutting the W1 jumper on the wall-bracket.
The buttons have the 2C terminal in common.
In this case the maximum acceptable current
to the three buttons is 0.5A.
Terminals
1 Video signal input 0.81.5Vpp
2 General ground
3 Video ground
4 Control switch ON - button
8 Positive power supply output for video
floor distributors 12Vdc
9 Door lock release - button
10 Call from the door station (180mA)
11 Audio ground
12 Microphone output
13 Speaker and automatic cancel
14 Positive power supply input 1824Vdc
V Not connected
Terminals
The terminals from 1 to 14 have the same functions and characteristics as the previous model.
V Activation input for digital systems
X1 AC power supply input 13Vac-0.35A
X2 Intercommunicating call input (ground command)
1C Common for P1, P2 and P3 buttons
2C Common for P4, P5 and P6 buttons
P1P6 Service buttons - max 60mA
138
5 7/16"
92
3 5/8"
U
P
WITHOUT COAX
Technical data
Power Supply
Operating current
Video tube
Television standard
Horizontal frequency
Vertical frequency
Bandwidth
Video signal on 75
Starting up time
Operating temperature
Max. permissible humidity
WB5660. The wall bracket includes 2 terminal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommunicating service (position A).
By using the PT5860 and PT5860W monitors
with multi-way systems without the intercommunicating service, the audio privacy can be
restored by positioning the jumper J1 in B.
1824Vdc
0.6A
4.5" - 90
625 lines
15625Hz
50Hz
>5MHz
0.81.5Vpp
57 sec.
0+50C
90%RH
140 150 cm
4" 7" 4" 11"
aaaaaaaaaaaaaaa
aaaaaaaaaaaaaaa
WITH COAX
U
P
6
(9GB-2002)
MODY
MONITORS
Project series
ERREP/R
J3
PROJECT
J2
PUNTOVIRGOLA
U
P
SLIM
J3
X1
X2
2C
1C
P1
P2
P3
P4
P5
P6
2
4
8
9
10
11
12
13
14
V
J1
1 2 3
J1
B
J2
W1
1 2 3
J1
1 2 3
WITHOUT COAX
R1
75
7
(9GB-2002)
WITH COAX
WB 5660
Inserting of extra buttons.
MODY
MONITORS
PuntoVirgola series
ERREP/R
76
3"
PROJECT
228
9"
PUNTOVIRGOLA
*
SLIM
PV2160. Two-colour flat tube monitor with audio-video privacy, electronic microphone, differentiated double electronic ringing sounds
(modulated and continuous note) and terminal board for the connection to the wallbracket. With two buttons, one for control
switch ON and one for door lock release, and
5 supplementary buttons, that can be added
for additional services such as: control switch
ON, intercommunicating calls, stair lights,
door lock release, etc. The buttons are included in the kit of the monitor. The maximum
acceptable current to the button terminals is
60mA. For higher currents use relay unit
art.1471. It can be installed on the wall (with no
built-in) by using the wall-bracket WB2100 or
WB2160. For particular needs it is possible to
separate the common of the buttons labeled T4
and T5 by cutting the W1 jumper on the wallbracket. The buttons have the 2C terminal in
common. In this case the maximum acceptable
current to the three buttons is 0.5A.
83.5
3 5/16"
WITHOUT COAX
1824Vdc
0.35A
4" FLAT CRT
625 lines
15625Hz
50Hz
>5MHz
0.81.5Vpp
24 sec.
0+50C
90%RH
Terminals
The terminals from 1 to 14 have the same functions and characteristics as the previous model.
V Activation input for digital systems
X1 AC power supply input 13Vac-0.35A
X2 Intercommunicating call input (ground command)
1C Common for T1, T2 and T3 buttons
2C Common for T4 and T5 buttons
T1T5 Service buttons - max 60mA
P1
Not connected
43
1 11/16"
U
P
40.5
1 5/ "
WB2160. The wall bracket includes 2 terminal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommunicating service (position A).
By using the PV2160 and PV2160W monitors
with multi-way systems without the intercommunicating service, the audio privacy can be
restored by positioning the jumper J1 in B.
122
4 13/16"
140 150 cm
4" 7" 4" 11"
aaaaaaaaaaaa
WITH COAX
8
(9GB-2002)
MODY
MONITORS
PuntoVirgola series
ERREP/R
*
PROJECT
U
P
PUNTOVIRGOLA
J2
J3
SLIM
1
3
V
14
13
12
11
10
9
8
4
2
R1
75
3
2
1
1 2 3
J1
J1
B
1 2 3
J1
WITHOUT COAX
T5
T4
T3
T2
T1
1C
2C
X2
X1
P1
WB2160
WITH COAX
9
(9GB-2002)
MODY
MONITORS
PuntoVirgola series
ERREP/R
149
5 7/8 "
90
3 9/16"
PROJECT
140
205 5 1/2 "
1
8 /16"
PUNTOVIRGOLA
*
SLIM
Technical data
Power Supply
Operating current
Video tube
Television standard
Horizontal frequency
Vertical frequency
Band width
Video signal on 75
Starting up time
Operating temperature
Max. permissible humidity
1824Vdc
0.6A
4.5"-90
625 lines
15625Hz
50Hz
>5MHz
0.81.5Vpp
57 sec.
0+50C
90%RH
WB1260. The wall bracket includes 2 terminal boards for connection to the system, it is
to be used when installing monitors with extra
buttons and/or 2 differentiated bells.
Located on the wall-bracket terminal board is
a J1 jumper positioned for the intercommunicating service (position A).
By using the PV1260 monitor with multi-way
systems without the intercommunicating service, the audio privacy can be restored by
positioning the jumper J1 in B.
Terminals
The terminals from 1 to 14 have the same functions and characteristics as the previous model.
V Activation input for digital systems
X1 AC power supply input 13Vac-0.35A
X2 Intercommunicating call input (ground command)
1C Common for P1, P2 and P3 buttons
2C Common for P4, P5 and P6 buttons
P1P6 Service buttons - max 60mA
WITHOUT COAX
X1 X2 2C 1C P1 P2 P3 P4 P5 P6
1
3
1
WITH COAX
2 4 8 9 10 11 12 13 14 V
W1
75
J1
J1
B
1
10
(9GB-2002)
J1
PuntoVirgola series
Project series
INTERCOMS
MODY
MONITORS
86
3 3 /8"
3 1 /16"
214
214
8 1 /16"
8 1 /16"
PROJECT
175
6 7/8 "
77.5
72
2 13/16"
ERREP/R
72
2 13/16"
60
2 3/8 "
Terminals
1 microphone
2 loudspeaker
3 ground
5 door release push-button (max 1A)
6 buzzer (absorption 0.2A)
9 electronic bell input
SLIM
aaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaa
140 150 cm
4 7"
4 11"
Terminals
1 microphone
2 loudspeaker
3 ground
5 door lock release button (max 1A)
6 buzzer (absorption 0.2A)
7 common push-buttons (
and 1)
9 electronic bell input
P1 service push-button (max 1A)
P2P9 service push-buttons (max 0.5A)
PUNTOVIRGOLA
126
415/16"
W1
W1
1
13Vca
X1
C
B
R1
11
(9GB-2002)
SM 50
N.B.: In the intercoms it is necessary to cut the
jumper W1 which links terminals 3 and 7; in the
SM50 module to cut the resistance R1.
1
3
1
4
8
9
10
11
12
13
14
2
CT
CT
5
6
3
1
2
5
6
3
1
2
75
VC
WITH COAX
2 1
10K
SR 40
X2
WITHOUT COAX
13Vac
MODY
PUSH-BUTTON PANELS
MODY series
ERREP/R
124
64
4 7 / 8"
1
2 / 2"
395
9
15 / 16 "
PROJECT
304.5
12 "
213
8 3 / 8"
PUNTOVIRGOLA
121.5
4 13 / 16"
MD 71
MD 72
Hood covers
MD 73
19
MD 74
/4"
151
276
5 15 /16"
SLIM
414.5
323
10 7 / 8"
16 5 /16"
12 11 /16"
231.5
9 1 / 8"
140
5 1 / 2"
MD 81
MD 82
MD 83
MD 804
MD 84
MD 86
401
15 13 /16"
151
5 15 /16"
414.5
MD 808
414.5
40
1 9 /16"
16 5 /16"
16 5 /16"
323
323
12 11 /16"
12 11 /16"
231.5
9 1 / 8"
WITHOUT COAX
140
5 1 / 2"
MD 89
MD 91
MD 92
MD 93
MD 812
25
1"
MD 904
276
401
10 7 / 8"
15 13 /16"
80
3 1 / 8"
414.5 16 5 / 16"
323 12 11 / 16"
231.5
WITH COAX
1
9 /8 "
MD 94
MD 96
MD 908
MD 99
12
(9GB-2002)
MD 912
65
2 9 /16"
MODY
PUSH-BUTTON PANELS
MODY series
25.5
91
3 9 /16"
1"
ERREP/R
ELECTRIC DOOR-SPEAKER
(amplifier)
MD 10
MD 11
MD 12
1 call button
2 call buttons
MD 22
MD 23
MD 24
1 call button
2 call buttons
3 call buttons
4 call buttons
Transmitter adjustable
volume
MD 21
PUNTOVIRGOLA
Button modules
MD 30.
It consists of a double amplifier (receiver and
transmitter) with adjustable volume of 2 channels. Also fittable to ErreP/R and Prestige
push-button panels (for the ErreP/R door stations by means of 299/1 adaptor).
PROJECT
55
2 3 /16"
SLIM
Terminals
1 receiver
2 transmitter
3 positive power supply 68Vdc - 60mA
4 ground
MD 122
MD 124
2 call buttons
4 call buttons
Button modules
MD 222
2 call buttons
MD 224
MD 226
MD 228
4 call buttons
6 call buttons
8 call buttons
50
MD 20
Blank module
FC 52P
Number module
MD 50
WITHOUT COAX
13
(9GB-2002)
WITH COAX
In any button module, to avoid the dismounting of name holder a screw 3MAx12 can be
inserted in the holes in order to block each
label.
MODY
PUSH-BUTTON PANELS
MODY series
ERREP/R
*
PROJECT
*
PUNTOVIRGOLA
5 5"
aaaaaaaaaa
SLIM
WITHOUT COAX
V
M
F
H
WITH COAX
14
(9GB-2002)
MODY
PUSH-BUTTON PANELS
MODY series
ERREP/R
*
PROJECT
*
PUNTOVIRGOLA
Hood covers
SLIM
V
M
F
H
WITHOUT COAX
Rain shelter
15
(9GB-2002)
WITH COAX
MODY
PUSH-BUTTON PANELS
1 row push-button
MODY series
ERREP/R
*
PROJECT
1 call button
2 call buttons
3 call buttons
4 call buttons
5 call buttons
6 call buttons
7 call buttons
PUNTOVIRGOLA
50
7 call buttons
8 call buttons
9 call buttons
10 call buttons
50
50
12 call buttons
14 call buttons
23 call buttons
24 call buttons
26 call buttons
11 call buttons
SLIM
50
16 call buttons
18 call buttons
19 call buttons
50
21 call buttons
50
27 call buttons
50
WITHOUT COAX
28 call buttons
30 call buttons
32 call buttons
34 call buttons
37 call buttons
38 call buttons
40 call buttons
42 call buttons
50
35 call buttons
50
WITH COAX
43 call buttons
48 call buttons
52 call buttons
16
(9GB-2002)
58 call buttons
1 row push-button
Compositions and
dimensions
1 MD30
1 MD11
1 MD41
1 MD30
1 MD12
1 MD41
1 MD30
1 MD10
1 MD23
1 MD41
1 MD30
1 MD10
1 MD41
1 MD30
1 MD41
1 MD30
1 MD41
8
9
124x213x19
(47/8" x 8 3/8" x 3/4")
5
6
124x304,5x19
(47/8" x 12" x 3/4")
248x213x19
(9 /4" x 8 3/8" x 3/4")
10
Hood
covers
Rain
shelter
1 MD72
1 MD82
1 MD92
1 MD72
1 MD82
1 MD92
1 MD73
1 MD83
1 MD93
1 MD24
1 MD73
1 MD83
1 MD93
1 MD11
1 MD24
1 MD73
1 MD83
1 MD93
1 MD12
1 MD24
1 MD73
1 MD83
1 MD93
1 MD30
1 MD10
1 MD24
1 MD23
2 MD72
1 MD84
1 MD94
1 MD41
1 MD30
1 MD10
2 MD24
2 MD72
1 MD84
1 MD94
1 MD41
1 MD30
1 MD11
2 MD24
2 MD72
1 MD84
1 MD94
1 MD12
2 MD24
2 MD72
1 MD84
1 MD94
1 MD30
1 MD10
2 MD24
1 MD23
2 MD73
1 MD86
1 MD96
12
1 MD41
1 MD30
1 MD10
3 MD24
2 MD73
1 MD86
1 MD96
13
1 MD41
1 MD30
1 MD11
3 MD24
2 MD73
1 MD86
1 MD96
14
1 MD41
1 MD30
1 MD12
3 MD24
2 MD73
1 MD86
1 MD96
15
1 MD41
1 MD30
1 MD10
3 MD24
1 MD23
2 MD73
1 MD86
1 MD96
16
1 MD41
1 MD30
1 MD10
4 MD24
2 MD73
1 MD86
1 MD96
17
1 MD41
1 MD30
1 MD11
4 MD24
2 MD73
1 MD86
1 MD96
18
248x304.5x19
(9 3/4" x 12" x 3/4")
1 MD41
1 MD30
1 MD12
4 MD24
2 MD73
1 MD86
1 MD96
19
1 MD41
1 MD30
1 MD10
4 MD24
1 MD23
2 MD74
1 MD808
1 MD908
20
1 MD41
1 MD30
1 MD10
5 MD24
2 MD74
1 MD808
1 MD908
21
1 MD41
1 MD30
1 MD11
5 MD24
2 MD74
1 MD808
1 MD908
22
1 MD41
1 MD30
1 MD12
5 MD24
2 MD74
1 MD808
1 MD908
23
1 MD41
1 MD30
1 MD12
5 MD24
1 MD21
2 MD74
1 MD808
1 MD908
24
1 MD41
1 MD30
1 MD12
5 MD24
1 MD22
2 MD74
1 MD808
1 MD908
1 MD41
1 MD30
1 MD12
5 MD24
1 MD23
2 MD74
1 MD808
1 MD908
25
26
248x395x19
(9 3/4" x 15 9/16" x 3/4")
1 MD30
1 MD12
6 MD24
2 MD74
1 MD808
1 MD908
27
1 MD41
1 MD30
1 MD11
5 MD24
2 MD23
3 MD73
1 MD89
1 MD99
28
1 MD41
1 MD30
1 MD10
7 MD24
3 MD73
1 MD89
1 MD99
1 MD41
1 MD30
1 MD11
7 MD24
3 MD73
1 MD89
1 MD99
30
1 MD41
1 MD30
1 MD12
7 MD24
3 MD73
1 MD89
1 MD99
31
1 MD41
1 MD30
1 MD11
6 MD24
2 MD23
3 MD74
1 MD812
1 MD912
32
1 MD41
1 MD30
1 MD12
6 MD24
2 MD23
3 MD74
1 MD812
1 MD912
33
1 MD41
1 MD30
1 MD11
8 MD24
3 MD74
1 MD812
1 MD912
34
1 MD41
1 MD30
1 MD12
8 MD24
3 MD74
1 MD812
1 MD912
35
1 MD41
1 MD30
1 MD12
8 MD24
1 MD21
3 MD74
1 MD812
1 MD912
36
1 MD41
1 MD30
1 MD12
8 MD24
2 MD21
3 MD74
1 MD812
1 MD912
37
1 MD41
1 MD30
1 MD11
8 MD24
2 MD22
3 MD74
1 MD812
1 MD912
38
1 MD41
1 MD30
1 MD12
8 MD24
2 MD22
3 MD74
1 MD812
1 MD912
29
39
372x304.5x19
(14 5/8" x 12" x 3/4")
372x395x19
(14 /8" x 15 9/16" x 3/4")
1 MD11
8 MD24
2 MD23
3 MD74
1 MD812
1 MD912
1 MD30
1 MD12
8 MD24
2 MD23
3 MD74
1 MD812
1 MD912
41
1 MD41
1 MD30
1 MD12
9 MD24
1 MD23
3 MD74
1 MD812
1 MD912
42
1 MD41
1 MD30
1 MD12
10 MD24
3 MD74
1 MD812
1 MD912
43
1 MD41
1 MD30
1 MD12
8 MD24
3 MD23
4 MD74
45
1 MD41
1 MD30
1 MD11
11 MD24
4 MD74
47
1 MD41
1 MD30
1 MD10
11 MD24
3 MD21
4 MD74
48
1 MD41
1 MD30
1 MD11
11 MD24
3 MD21
4 MD74
50
1 MD41
1 MD30
1 MD10
11 MD24
3 MD22
4 MD74
1 MD41
1 MD30
1 MD12
11 MD24
3 MD22
4 MD74
1 MD41
1 MD30
1 MD10
11 MD24
3 MD23
4 MD74
1 MD41
1 MD30
1 MD12
11 MD24
3 MD23
4 MD74
1 MD41
1 MD30
1 MD12
14 MD24
4 MD74
52
53
55
58
496x395x19
(19 1/2" x 15 9/16" x 3/4")
17
(9GB-2002)
Optional
It replaces
MD72, 73, 74
WITH COAX
1 MD30
1 MD41
1 MD41
40
WITHOUT COAX
1 MD41
SLIM
1 MD30
1 MD41
1 MD41
11
PUNTOVIRGOLA
1 MD41
Module for
speaker
PROJECT
Door speaker
(amplifier)
Camera
module
ERREP/R
N
calls
MODY series
MODY
PUSH-BUTTON PANELS
MODY
PUSH-BUTTON PANELS
2 row push-button
MODY series
ERREP/R
*
PROJECT
6 call buttons
8 call buttons
10 call buttons
12 call buttons
PUNTOVIRGOLA
50
14 call buttons
16 call buttons
18 call buttons
20 call buttons
24 call buttons
28 call buttons
46 call buttons
48 call buttons
52 call buttons
22 call buttons
SLIM
50
32 call buttons
36 call buttons
38 call buttons
50
42 call buttons
50
54 call buttons
50
WITHOUT COAX
56 call buttons
60 call buttons
64 call buttons
68 call buttons
74 call buttons
76 call buttons
80 call buttons
84 call buttons
50
70 call buttons
50
WITH COAX
86 call buttons
96 call buttons
18
(9GB-2002)
MODY
*
1 MD122
1 MD72
1 MD82
1 MD92
1 MD30
1 MD124
1 MD72
1 MD82
1 MD92
1 MD41
1 MD30
1 MD10
1 MD226
1 MD73
1 MD83
1 MD93
1 MD41
1 MD30
1 MD10
1 MD228
1 MD73
1 MD83
1 MD93
1 MD41
1 MD30
1 MD122
1 MD228
1 MD73
1 MD83
1 MD93
1 MD41
1 MD30
1 MD124
1 MD228
1 MD73
1 MD83
1 MD93
14
1 MD41
1 MD30
1 MD10
1 MD228
2 MD72
1 MD84
1 MD94
16
1 MD41
1 MD30
1 MD10
2 MD228
2 MD72
1 MD84
1 MD94
18
1 MD41
1 MD30
1 MD122
2 MD228
2 MD72
1 MD84
1 MD94
20
1 MD41
1 MD30
1 MD124
2 MD228
2 MD72
1 MD84
1 MD94
22
1 MD41
1 MD30
1 MD10
2 MD228
2 MD73
1 MD86
1 MD96
24
1 MD41
1 MD30
1 MD10
3 MD228
2 MD73
1 MD86
1 MD96
26
1 MD41
1 MD30
1 MD122
3 MD228
2 MD73
1 MD86
1 MD96
28
1 MD41
1 MD30
1 MD124
3 MD228
2 MD73
1 MD86
1 MD96
30
1 MD41
1 MD30
1 MD10
3 MD228
2 MD73
1 MD86
1 MD96
32
1 MD41
1 MD30
1 MD10
4 MD228
2 MD73
1 MD86
1 MD96
34
1 MD41
1 MD30
1 MD122
4 MD228
2 MD73
1 MD86
1 MD96
10
12
1 MD30
1 MD124
4 MD228
2 MD73
1 MD86
1 MD96
1 MD41
1 MD30
1 MD10
4 MD228
2 MD74
1 MD808
1 MD908
40
1 MD41
1 MD30
1 MD10
5 MD228
2 MD74
1 MD808
1 MD908
42
1 MD41
1 MD30
1 MD122
5 MD228
2 MD74
1 MD808
1 MD908
44
1 MD41
1 MD30
1 MD124
5 MD228
2 MD74
1 MD808
1 MD908
46
1 MD41
1 MD30
1 MD124
5 MD228
2 MD74
1 MD808
1 MD908
48
1 MD41
1 MD30
1 MD124
5 MD228
2 MD74
1 MD808
1 MD908
1 MD41
1 MD30
1 MD124
5 MD228
2 MD74
1 MD808
1 MD908
50
52
248x395x19
(9 3/4" x 15 9/16" x 3/4")
6 MD228
2 MD74
1 MD808
1 MD908
1 MD122
5 MD228
3 MD73
1 MD89
1 MD99
56
1 MD41
1 MD30
1 MD124
7 MD228
3 MD73
1 MD89
1 MD99
58
1 MD41
1 MD30
1 MD122
7 MD228
3 MD73
1 MD89
1 MD99
60
1 MD41
1 MD30
1 MD124
7 MD228
3 MD73
1 MD89
1 MD99
62
1 MD41
1 MD30
1 MD122
6 MD228
3 MD74
1 MD812
1 MD912
64
1 MD41
1 MD30
1 MD124
6 MD228
3 MD74
1 MD812
1 MD912
66
1 MD41
1 MD30
1 MD122
8 MD228
3 MD74
1 MD812
1 MD912
68
1 MD41
1 MD30
1 MD124
8 MD228
3 MD74
1 MD812
1 MD912
70
1 MD41
1 MD30
1 MD124
8 MD228
3 MD74
1 MD812
1 MD912
72
1 MD41
1 MD30
1 MD124
8 MD228
3 MD74
1 MD812
1 MD912
74
1 MD41
1 MD30
1 MD122
8 MD228
3 MD74
1 MD812
1 MD912
76
1 MD41
1 MD30
1 MD124
8 MD228
3 MD74
1 MD812
1 MD912
78
1 MD41
1 MD30
1 MD122
8 MD228
3 MD74
1 MD812
1 MD912
80
1 MD41
1 MD30
1 MD124
8 MD228
3 MD74
1 MD812
1 MD912
82
1 MD41
1 MD30
1 MD124
9 MD228
3 MD74
1 MD812
1 MD912
84
1 MD41
1 MD30
1 MD124
10 MD228
3 MD74
1 MD812
1 MD912
86
1 MD41
1 MD30
1 MD124
8 MD228
4 MD74
90
1 MD41
1 MD30
1 MD122
11 MD228
4 MD74
94
1 MD41
1 MD30
1 MD10
11 MD228
4 MD74
96
1 MD41
1 MD30
1 MD122
11 MD228
4 MD74
100
1 MD41
1 MD30
1 MD10
11 MD228
4 MD74
104
1 MD41
1 MD30
1 MD124
11 MD228
4 MD74
106
1 MD41
1 MD30
1 MD10
11 MD228
4 MD74
110
1 MD41
1 MD30
1 MD124
11 MD228
4 MD74
116
1 MD41
1 MD30
1 MD124
14 MD228
4 MD74
19
(9GB-2002)
WITH COAX
1 MD124
1 MD30
1 MD30
1 MD41
WITHOUT COAX
1 MD41
54
SLIM
1 MD41
38
248x304.5x19
(9 3/4" x 12" x 3/4")
PUNTOVIRGOLA
36
124x304,5x19
(47/8" x 12" x 3/4")
PROJECT
1 MD30
1 MD41
124x213x19
(47/8" x 8 3/8" x 3/4")
1 MD41
ERREP/R
MODY
PUSH-BUTTON PANELS
MODY series
ERREP/R
CAMERAS
52
124
2 1 /16"
4 7 /8"
52
PROJECT
90
90
90
3 9 /16"
3 /16"
9
3 9 /16"
PUNTOVIRGOLA
19
3
/4"
MD 41.
This module includes:
- solid-state camera (CCD) with auto iris, 3.6mm
fixed optics and 6 infrared-ray LEDs.
- front plate in anodized aluminium, with breakproof transparent screen.
- horizontal and vertical sweep.
MD 41C Color.
Colour version of model MD41.
SLIM
Terminals
V video signal output
M ground
F not connected
H positive power supply
input 21Vdc
V
M
F
H
Sweeps
If necessary, you can manually change the camera
framing by unloosening and adjusting the horizontal or
vertical screw in the desired direction (or both screws if
you want to adjust the image in all directions).
horizontal
45
1 3 /4 "
4 7 /8"
2 1 /16"
4 7 /8"
19
19
3
/4"
FC52P.
Access control keypad with 12 digits and 2
relays for lock release. 4 programmable
access codes for each relay. Programmable door opening time from 1 up 99 sec. for
each relay (or bistable operation of one
relay). Acoustic confirmation for entered
keys, accepted programming and for wrong
codes.
Power supply: 13VAC/DC-0.1A.
Technical data
Power supply:
12Vac/dc 10%
Stand-by current:
0.015A
Maximum current consumption: 0.1A
Contact ratings:
12VAC-5A
Numbers of codes for relays 1: 4
Numbers of codes for relays 2: 4 or direct
activation
Activation time for each relay: from 1 to 99 sec.
(or bistable relay 1)
Operating temperature:
0 +40C
Maximum permissible humidity:
85% RH
Terminals
1 normally closed contact of relays 2
2 normally open contact of relays 2
3 common contact of relays 2
4 normally closed contact of relays 1
5 normally open contact of relays 1
6 common contact of relays 1
7 ground or alternate voltage input
8 positive or alternate voltage input
/4"
12
WITHOUT COAX
vertical
12Vca
12V
13Vac
Relay
Rel1 1
12Vcc
Relay
Rel2 2
WITH COAX
Technical data
MD41
MD41C
Power supply
Operating current
Output video signal
Standard segnale video
Minimum illumination
White balance
Sensor
Pixel number
Horizontal frequency
Vertical frequency
Lens
Adjustable focus
Auto-iris
Horizontal sweep
Vertical sweep
Operating temperature
Maximum permissible humidity
213Vdc
0.2A
1Vpp on 75
CCIR
2 Lux
CCD 1/4" B/W
291000
15625Hz
50Hz
3.6mm; F5
0.1m
electronic
15
15
-10+40C
80%RH
213Vdc
0.4A
1Vpp on 75
PAL
2.5 Lux
auto
CCD 1/3" colour
291000
15625Hz
50Hz
4mm; F4
0.6m
electronic
15
15
-10+40C
80%RH
20
(9GB-2002)
Note
The specifications of
MD40 and MD40C cameras are the same as
MD41 and MD41C models, except for pan&tilt,
which is not available.
1
2
3
4
5
6
Lamp terminals
Button terminal board
Call buttons common
Stair light button terminals
External volume adjustment
Terminal board for audio/powering
MODY
PUSH-BUTTON PANELS
112
50
ErreP/R series
4 7/16"
1 15/16"
1 9 /16"
ERREP/R
CAMERA UNIT
ErreP/R series
122
4 13 /16"
164
6 1/8 "
6 7 /16"
PROJECT
1 2 3 4
155.5
1
2
3
4
Receiver
Transmitter
Power supply 68Vdc -60mA
Ground
SLIM
Technical data
Power supply
Operating current
Video signal on 75
Minimum illumination
Pixel number
Horizontal frequency
Vertical frequency
Lens
Adjustable focus
Opening of auto-iris
Operating temperature
Maximum permissible humidity
Terminals
PUNTOVIRGOLA
1385R.
The camera unit is used in the multi-way
video systems composed of:
M V F A H
Terminals
M Video ground (shield of coaxial cable)
V Video output signal 1Vpp (coaxial cable)
F General ground
A Alternate voltage input for name plate lights
and climatizing circuit 13Vac-40mA
H Positive power supply input for camera and
infrared LEDs 213Vdc-260mA
Technical data
Power supply:
13Vac
Operating current: 130mA
Terminals
1 Receiver
2 Transmitter
C Common call buttons
P1 Call button
P2 Call button
- Ground
Alternate voltage input 13Vac
376 14 13 /16"
8 5 /8 "
RP12
RP10
RP8
RP4
RP6
RP2
RP
313 12 5 /16"
282 11 1 /16"
250 9 13 /16"
219
RP. Push-button panels with anodized aluminium front panel and buttons, complete
with name plate lights and height adjustable
contacts to compensate imperfections of the
wall. The electric door speaker can be fitted
inside the push-button panel.
WITHOUT COAX
313 12 5 /16"
282 11 1 /16"
250 9 13 /16"
219
8 5 /8 "
R12
R10
R8
21
(9GB-2002)
WITH COAX
R14
*
*
ErrreP/R series
ERREP/R
MODY
PUSH-BUTTON PANELS
Installation notes
Among the back-box of the camera unit and
the push-button panel apply, before mounting
on to the wall, the tips and fair leads provided
in the kit.
PROJECT
ALTO
UP
PUNTOVIRGOLA
1385R
1
6 /4 "
ALTO
UP
1385R
1
6 /4 "
5 13/16"
1385R
1385R
RP..
RP..
R..
RP..
R..
RP..
SLIM
4 11 "
9
1 /16"
40mm 1 9 /16"
aaaaaaa
9
1 /16"
Instructions of the various ErreP/R push-button panel series and their dimensions en mm (and inches)
L and H = Dimensions of the panel
WITHOUT COAX
Series
L
H
RP
112 (4 7/16")
R+RP
R+RP+R
R+RP+R+R
R+R+RP+R+R
224 (8 13/16")
L
h
R8
RP1
R8+RP1=9
2R8+RP1=17
3R8+RP1=25
4R8+RP1=33
R8
RP2
R8+RP2=10
2R8+RP2=18
3R8+RP2=26
4R8+RP2=34
250
(9 13/16")
R10
RP4
R10+RP4=14
2R10+RP4=24
3R10+RP4=34
4R10+RP4=44
238
(9 3/8")
281.5
(11 1/16")
R12
RP6
R12+RP6=18
2R12+RP6=30
3R12+RP6=42
4R12+RP6=54
269.5
(10 5/8")
313
(12 5/16")
R14
RP8
R14+RP8=22
2R14+RP8=36
3R14+RP8=50
4R14+RP8=64
301
(11 7/8")
215 (8 7/16")
218.5
(8 5/8")
WITH COAX
103 (4 1/16")
22
(9GB-2002)
206.5
(8 1/8")
MODY
89
3 1 /2"
PRS210. TRANSFORMER.
Technical data
Turn ON time: -50 sec. with handset replaced
-3 min. with handset lifted
Operating temperature
0+50C
Maximum permissible humidity 90%RH
Housing
DIN 6 modules A
Terminals
I Logic command output of timing 0/5Vdc
+ Positive voltage input 1828Vdc-2A
- Ground
A Alternating voltage input-output 13Vac-1.6A
D Alternating voltage output for the common of
push-button 13Vac-0.5A (intermittent service)
H Timed positive voltage output for the camera
unit 1828Vdc-0.5A max.
F Ground
1 Transmitter audio channel input 4.5Vdc-10mA
2 Receiver audio channel input 2Vdc-16mA
3 Positive voltage output 8Vdc-0.1A
S Electronic door lock release 1A
4 Control switching ON input from the monitors
5.5Vdc-90mA
9 Door lock release command 50mA
11 Audio ground
12 Transmitter audio channel output 4.5Vdc10mA
13 Receiver audio channel output 2Vdc-16mA
14 Timed positive voltage output for the monitors
1828Vdc-1.5A max.
Technical data
Input voltage: 127V or 230Vac
Power: 15VA
Output voltage: 13Vac
Maximum current with direct use: 0.7A
Maximum current with intermittent: 1A
Housing: DIN 3 modules A
Weight: 0.42Kg
Approved: VDE
Operating temperature: 0 +50C
Maximum permissible humidity: 90% RH
1443E
1443E
WITHOUT COAX
Note
- The power supply is not provided with fuses,
but all of its outputs are protected against
overloading and short circuiting by temperature sensors. To reset the power supply, power must be cut off for about one minute and
can be restored after having eliminated the
defect.
- The power supply must be installed in a dry
place and can be fixed on DIN bar or on a wall
by using the expansion plugs.
- The connection between power supply 1281
and timer 1382 is not to be longer than 25cm.
54
2 1 /8"
SLIM
Terminals
A Output voltage 13Vac for:
-name plate light, exchangers and climatized
camera (continuous service 0.6A)
-electric door lock and bells (intermittent service 1A)
- Ground
+ Continuous output 21Vdc-1A (timed operation)
I Logic command input from timing
0 = activated
+5Vdc = non activated
3 /2"
1
Technical data
Input voltage
127 or 230Vac
Frequency
50/60Hz
Power
48VA
Operating temperature
0+50C
Maximum permissible humidity 90%RH
Housing
DIN 8 modules A
Weight
0.95Kg.
89
PUNTOVIRGOLA
4 1 /4"
89
3 1/2 "
PROJECT
107.5
2 9 /16"
140
5 1/2 "
65
2 9 /16"
ERREP/R
65
74
2 15/16"
1282E
1382
WITH COAX
23
(9GB-2002)
MODY
SERVICE MODULES
ERREP/R
*
74
2 15/16"
PROJECT
140
5 1/2 "
PUNTOVIRGOLA
*
SLIM
1
2
3
4
5
7b
ON (b)
2 /16"
7a
8b
8a
9b
9a
54
89
2 3 /4"
1273TV. EXCHANGER.
2 9 /16"
70
89
3 1/2 "
65
65
2 1 /8"
3 1 /2"
89
3 1 /2"
Terminals
F General ground
B Power supply 8Vdc-60mA
Power supply 13Vac-70mA
12 Connection toward the microphone of the
monitors
12a Audio output from door station (transmitter
channel)
13 Connection towards the speaker of the monitors
13a Audio input from the door station (receiver
channel)
14 Timed power supply for the audio connection toward the door station 1224Vdc-60mA
0 From the jumper with F when the terminal 14
is powered to 12Vdc (terminal 8 of the monitor)
Terminals
1 13Vac input
2 24Vdc input
3 Ground
5 Common relay
6 Relay contact - ON
7 Relay contact - OFF
Note
If it is necessary to adjust the volume of the
intercommunicating audio turn trimmer R5.
MEMORY
OFF (a)
6
7
8
9
12
13
14
WITHOUT COAX
AMPL.
10
11
12
13
12a
WITH COAX
1473. EXCHANGER.
It is different from the previous one in that it
has a reduced number of exchanges (4 instead of 7), and for the presence of 3 terminals (11, 12 and 13) for switching the relay
using a ground commands.
24
(9GB-2002)
13a
MODY
VIDEO MEMORY
42
5 1/4 "
1 5/8 "
supplementary push-button on
the monitors. The video
memory should be powered
with 13V either ac or dc using
an external transformer or
power supply (e.g. PRS210).
123
IN
OUT
12V
8 + 3 3 D R A P
PUNTOVIRGOLA
*
SLIM
Operating instructions.
It is advisable to install the video memory
close to the monitor, using the push-button
command on the video memory. If the recommended configuration is not achievable or in
the system there is more than one monitor it
would be possible to connect in parallel to the
main commands (DEL, REC, AUTO and
PLAY) located on the video memory using the
Technical data
Power supply: 12Vac/dc
Current consumption: 0.4A
Video signal standard: CCIR
Recording delay after a call: 5 sec
Rec. inhibition after an image storing: 30sec
Memory capacity: 32 images
Hour, data maintaining in case of power failure:
5 min
PROJECT
5 1/8 "
130
Terminals
IN
Video input 1Vpp composite into 75
OUT Video output 1Vpp composite into 75
12V Power supply 12V either ac or dc
8 12Vdc input (from the monitor)
+ 12Vdc output (to the video distributors)
3 Ground
D Supplementary input of the Del command
R Supplementary input of the Rec command
A Supplementary input of the Auto command
P Supplementary input of the Play command
ERREP/R
133
INSTALLATION DIAGRAMS
Connection of the video memory in one-way systems.
In one-way systems with one or more monitors in parallel, it is sufficient to connect the
coaxial cable from the video camera unit to
the terminal IN of the video memory the
terminal OUT should be connected to the
video input of the monitor.
The connections P, A, R and D drawn with
dashed lines on the diagram, must be done
only if additional commands are required on
the monitor or if there is one or more monitors
in parallel.
PRS210
230V
127V
0
1 2 3
A
B
12V
P
A
R
D
8
OUT
OUT
8 + 3 3 D R A P
25
(9GB-2002)
P1
P2
P3
P4
8
1
3
1
10
4
9
11
12
13
14
2
VC
T1
T2
T3
T4
8
1
3
1
10
4
9
11
12
13
14
2
VC
VM32
12V
12V
+
IN
IN
J1
VM
P
A
R
D
8
OUT
OUT
P1
P2
P3
P4
8
1
3
1
10
4
9
11
12
13
14
2
VC
T1
T2
T3
T4
8
1
3
1
10
4
9
11
12
13
14
2
VC
WITH COAX
OUT
1 2 3
AS
IN
J1
PRS210
WITHOUT COAX
1 2 3
VM
12V
12V
+
IN
IN
AS
VM32
MODY
INSTALLATION INSTRUCTIONS
ERREP/R
50m
165 Ft
distance
100m 330 Ft
200m
660 Ft
300m
990 Ft
terminal
art. 1382
PROJECT
S mm
AWG
S mm
AWG
S mm
AWG
S mm
AWG
4 - 9 - 11 - 12 - 13
H-1-2-3-F-D
10 (call)
0.5
20
0.75
18
16
1.5
16
F - 14 - A - S
0.75
18
16
1.5
16
2.5
12
Insertion loss
Max. input video signal
Bandwidth
IN
OUT 2
OUT 1
OUT 4
OUT 3
Serial connection of the coaxial cable (input and output from monitor)
75
VC
PT5100
PT5160
WITHOUT COAX
PV1200
PV1260
75
8
1
3
1
2
4
20
75
75
8
1
3
1
VC
IN
OUT1
IN
1385R
VC
8
1
3
1 75
DV2-4
OUT2
VC
75
PT5600
PT5660
PT5800
PT5860
MD41
12
PV2100
PV2160
PT5600
PT5660
PT5800
PT5860
1385R
8
1
3
1
PT5100
PT5160
PV2100
PV2160
VC
8
1
3
1
MD41
WITH COAX
V
M
V
M
26
(9GB-2002)
IN
12Vdc2
50mA
100mA
0.8dB
2Vpp
>5MHz
DV2
DV4
Technical data
Power supply
Operating current
SLIM
PUNTOVIRGOLA
1
+
IN
DV2-4
OUT1
IN
OUT2
VC
8
1
3
1 75
PV1200
PV1260
MODY
INSTALLATION INSTRUCTIONS
Terminals
F General ground
14 Positive power supply
IN Video signal input
1-2-3-4-5 Video signal outputs
Video ground (shield of the coaxial cable)
75
75
20
VC
8
1
3
1
75
OUT1
IN
OUT2
75
PT 5100
PT 5160
VC
8
1
3
1
75
5600
5660
5800
5860
8
1
3
1
VC
IN
8
1
3
1 75
DV2-4
OUT1
IN
OUT2
PT
PT
PT
PT
PV 2100
PV 2160
1385R
8
1
3
1 75
DV2-4
MD41
OUT
2
4
5600
5660
5800
5860
1382
476
14
F
IN
V
M
1
3
SLIM
PT
PT
PT
PT
2
4
VC
VC
1
12
+
IN
PV 1200
PV 1260
PT 5100
PT 5160
8
1
3
1
PUNTOVIRGOLA
VC
PROJECT
Connection of the coaxial cable with distribution on maximum 5 column rising (serial and/or with video floor distributors)
Technical data
Power supply
21 3Vdc
Operating current at max. load
250mA
Gain at max. load from 0 to 3.5dB (adjustable)
Gain with one output closed to 75 from 0 to 9dB
(adjustable)
Bandwidth
>5MHz
Operating temperature
0+50C
Maximum permissible humidity
90% RH
Housing DIN 8 modules A
ERREP/R
14
F
1385R
MD41
476
VC
75
2
4
5600
5660
5800
5860
IN
OUT
14 F
14 F
476
230V
127V
14 F
F
A
I
A
I
1281
1281
1382
For this use, one output is to be connected; do not close the other outputs on the 75 resistance.
8
1
3
1
PV 1200
PV 1260
MD41
3
OUT
V
M
IN
TR 1382
476
14
F
14
F
1281
F
A
I
27
(9GB-2002)
A
I
230V
127V
0
WITH COAX
1385R
75
PT
PT
PT
PT
IN
230V
127V
0
PV 2100
PV 2160
VC
1
20
8
1
3
1
PT 5100
PT 5160
3
OUT
WITHOUT COAX
V
M
MODY
WORKING INSTRUCTIONS
ERREP/R
*
PROJECT
*
PUNTOVIRGOLA
SLIM
PT5160
V
M
H
H
D
1
2
3
1
2
3
4
F
A
S
UR
1382
SE
4
9
11
12
13
14
F
A
I
+
TR
PT5660
PT5860
PA
AL
AL
1281
1281
Mody
+
I
A
1
0
127V
230V
0
127V
230V
"door lock
release"
"control
switch ON"
WITHOUT COAX
D
3
S
1
2
H
F
A
1382
10
1
3
1
8
4
9
11
12
13
14
2
4
9
11
12
13
14
F
A
I
+
WITH COAX
1281
75
"door lock release"
TR
AL
AL
PV2160
PV1260
A +
1281
+
I
A
0
127V
230V
0
127V
230V
28
(9GB-2002)
MODY
TROUBLESHOOTING
Audio section
Intercommunicating systems
WITHOUT COAX
Unfocused image.
Adjust correctly the lens of the camera. Defective camera.
SLIM
PUNTOVIRGOLA
PROJECT
Preliminary checks
- Check for the presence of the mains voltage
between terminals 230 (or 127) and 0 of the
power supply.
- The power supply is not provided with fuses,
but all of its outputs are protected against
overloading and short circuiting by temperature sensors. To reset the power supply, power must be cut off for about one minute and
can be restored after having eliminated the
defect.
ERREP/R
WITH COAX
29
(9GB-2002)
MODY
*
ERREP/R
INSTALLATION DIAGRAMS
PROJECT
The following pages show the installation diagrams most often used in the video-intercom system. Upon request Farfisa supplies
installation diagrams for the configurations not present in this manual.
PUNTOVIRGOLA
For a clearer understanding of the diagrams, the sequence of terminals in each individual article has not been followed. Only the
terminal code is valid (letter e/o number) not the graphic sequence.
The items may have more terminals than the ones in the installation diagrams. The excess terminals must not be utilized.
SLIM
The conduit of the wires of any video and video-intercom system must be carried out separately from the light or industrial system
as prescribed from the International standards.
It is advisable to provide behind the (fused spur) power supply a disconnecting and safety switch.
Before connecting the unit, make sure its data correspond to those of the mains.
The installation diagrams for 1 or more external stations illustrated in this technical manual have been represented with a one
monitor for each user. However, it is possible to personalise the installation by matching properly to the base diagrams of pages
31, 33, 37, 39, 41, 43, the applications of pages 50, 51, 52, 53, and 54. For further details, see page 48.
The installation diagrams from page 33 to page 47 use control panels of Mody or ErreP/R series (and camera unit 1385R), and
they can also be used for one-way installations and video kits of the Mody series. Connect one monitor, by using a one call wire,
and not the video distributor (the coaxial cable is connected directly to the monitor wall bracket).
Graphic designs
WITHOUT COAX
For a better comprehension of the installation diagrams we have made a list of the graphic symbols most often used.
Speaker
Coaxial cable
Microphone
Button
N2
Nn
Buzzer
Dashed line (for schematic purposes the first and last monitors are designed in the multi-family systems. Theoretically
the needed monitors are inserted in such dashed lines to
complete the system)
*
SR
40
WITH COAX
Resistance
Lamp
30
(9GB-2002)
MODY
Power supply
Timer
Intercommunicating module
MD41+MD72+MD11+MD30
1281
1382
MD41+MD72+MD11+MD30
1281
1382
PT5100MDCW
PT5160WLCD+WB5100
MD41C+MD72+MD11+MD30
1281
1382
PT5160MD
PT5160+WB5160
MD41+MD72+MD11+MD30
1281
1382
1443E
PT5160MDW
PT5160W+WB5160
MD41+MD72+MD11+MD30
1281
1382
1443E
PT5160MDCW
PT5160WLCD+WB5160
MD41C+MD72+MD11+MD30
1281
1382
1443E
PT5600MDW
PT5660W+WB5600+1283
MD41+MD72+MD11+MD30
1281
1382
PT5660W+WB5660+1283
MD41+MD72+MD11+MD30
1281
1382
1443E
PT5860W+WB5600
MD41+MD72+MD11+MD30
1281
1382
PT5860MDW
PT5860W+WB5660
MD41+MD72+MD11+MD30
1281
1382
1443E
PV1200MD
PV1260+WB1200+1283
MD41+MD72+MD11+MD30
1281
1382
PV1260MD
PV1260+WB1260+1283
MD41+MD72+MD11+MD30
1281
1382
1443E
PV2100MD
PV2160+WB2100
MD41+MD72+MD11+MD30
1281
1382
PV2160MD
PV2160+WB2160
MD41+MD72+MD11+MD30
1281
1382
1443E
PT5660MDW
PT5800MDW
PROJECT
PT5160+WB5100
PT5160W+WB5100
PT5100MD
PT5100MDW
ERREP/R
Videokit
PUNTOVIRGOLA
*
SLIM
Si 5000M
ONE-WAY VIDEOKIT WITH APPLICATION OF THE MULTIPOLAR CABLE art.1304
Graphic overlap point for extension of diagram (see page 48).
MD41
coaxial
coaxial
light blue
MD11
SE
PA
black
green
white
pink
orange
grey
red
yellow
blue
4
9
D
H
1
2
3
11
12
13
14
F
A
I
+
F
S
A
black
green
light blue
yellow
white
pink
blue
red
8
1
3
1
4
9
10
11
12
13
14
2
VC
75
TR
1382
+
I
A
AL
max 50m
WITHOUT COAX
1
2
MD30 3
MD72
Art. 1304
Art. 1304
H
M
V
max 50m
1281
127V
230V
31
(9GB-2002)
WITH COAX
1304. Multipolar cable with 10 wires of different cross sections and coaxial cable of
75. It can be used in systems with a maximum distance of 100 meters (50m between
timer and camera unit and 50m between timer
and monitor).
VC =PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
MODY
Si 5050
ERREP/R
Description
VC
...
DV
AL
TR
PA
SE
...
1
1
1
1
PROJECT
*
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
1281
1382
**
**
DV
9+coax
8+coax
PUNTOVIRGOLA
PT5160 +
WB5100
7+(n-1)+coax
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
1
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
1
MD82 812 MD82 812
Hood covers
1
MD92 912* MD92 912* Rain shelters
PE
1
MD30
MD30
Electric door speaker
DV
9+coax
PV2160 +
WB2100
7+n+coax
1281
PE
1
1
...
1
1
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
1382
9+n+coax
Mody
SE
2
Working instructions
See page 28.
WITHOUT COAX
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 8 lamps (24V3W). If this number is exceeded, one or more
12V transformers and an proper power will be
required (type PRS210).
- If the control switch ON is needed connect
terminal 4 of the timer (dashed line).
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
For one-way systems or video kits of the
Mody series, connect the coaxial cable directly to the monitor wall bracket, without
using the DV floor video distributor (see diagram on page 31).
PA
1382
TR
F A
9 11 12 13 14 F
H 1
2 3
A
I
A
I
+ 1281 AL
230V
127V
0
MD21
MD22
MD23
MD24
2
1
MD100
MD200
Mody
H
V
M
WITH COAX
MD41
PA
MD72-73-74
SE
32
(9GB-2002)
Si 5050
ERREP/R
75
in
in
DV
MODY
VC n
8
1
3
1
4
9
10
11
12
13
14
2
+
out
75
PROJECT
*
PUNTOVIRGOLA
in
in
DV
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
+
out
75
2
4
SLIM
1
3
TR
F A
9 11 12 13 14 F
H 1
2 3
A
I
A
I
230V
127V
0
AL
ErreP/R
Mody
4
3
2
1
PE
PA
H
V
M
A
F
UR
UR
SE
33
(9GB-2002)
WITH COAX
H
V
M
PE
4
3
2
1
PB
WITHOUT COAX
PB
MODY
Multi-way systems
Si 5051
ERREP/R
Description
VC
...
CT
...
PROJECT
*
PUNTOVIRGOLA
SC
DV
AL
TR
PA
SE
...
...
1
1
1
1
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
PT510
PT520
SM50
DV2-4
1281
1382
**
**
DV
9+coax
8+coax
PT5160 +
WB5100
DV
9+coax
PV2160 +
WB2100
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
1
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
1
MD82 812 MD82 812
Hood covers
1
MD92 912* MD92 912* Rain shelters
PE
1
MD30
MD30
Electric door speaker
PE
1
1
...
1
1
1385R
RP...
R...
290R/2 290R/38
337C
7+(n-1)+coax
7+n+coax
PT510+
SM50
1281
7+(n-2)+coax
1382
9+n+coax
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
Mody
SE
2
PA
WITHOUT COAX
Working instructions
It is similar to the basic system described on
page 28, but with the following variations:
- from the intercom the user has about 40
seconds to answer by lifting the handset and
therefore can speak for an unlimited time with
video privacy towards the other users. By
replacing the handset the system shuts itself
OFF.
WITH COAX
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 8 lamps (24V-3W).
If this number is exceeded, one or more 12V
transformers and an proper power will be required (type PRS210).
- If the control switch ON is needed connect
terminal 4 of the timer (dashed line).
- If secrecy of conversation is not needed, all
the systems 4+1 Farfisa can be used.
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
W1
C
B
10K
2 1
R1
SM 50
34
(9GB-2002)
Si 5051
ERREP/R
75
in
in
DV
VC n
8
1
3
1
4
9
10
11
12
13
14
2
+
out
MODY
Multi-way systems
75
PROJECT
*
PUNTOVIRGOLA
in
in
DV
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
+
out
SLIM
The 75 resistance
inserted between terminals 1 and 3 of monitors
is supplied with the product. It is not to be added.
75
CT
CT + SC
C
B
5
7
3
2
1
6
3
2
1
6
5
7
3
2
1
6
TR
F A
Intercom without
audio privacy.
9 11 12 13 14 F
H 1
2 3
A
I
A
I
230V
127V
0
AL
ErreP/R
Mody
4
3
2
1
PE
PA
H
V
M
A
F
UR
UR
SE
35
(9GB-2002)
WITH COAX
H
V
M
PE
4
3
2
1
PB
WITHOUT COAX
PB
MODY
ERREP/R
Description
VC
...
DV
AL
TR
DS
PA
SE
...
1
1
1
2
2
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
1281
1382
1473
**
**
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
2
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
2
MD82 812 MD82 812
Hood covers
2
MD92 912* MD92 912* Rain shelters
PE
2
MD30
MD30
Electric door speaker
ErreP/R series (see pages 21, 22 for the composition)
UR
PB
PE
1
2
...
2
2
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
WITHOUT COAX
*
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 6 lamps (24V3W). If this number is exceeded, one or more
12V transformers and an proper power will be
required (type PRS210).
- If the control switch ON is needed connect
terminal 4 of the timer (dashed line).
- In this system the control switch ON from the
monitors can interrupt a running communication, for this reason it is advisable to interrupt
it by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
For one-way systems or video kits of the
Mody series, connect the coaxial cable directly to the monitor wall bracket, without
using the DV floor video distributor.
DV
9+coax
8+coax
Working instructions
It is similar to the basic system
described on page 28, but with
the following variations:
- Carrying out a call from the
entrance only audio, the corresponding monitor turns itself
ON without images.
- The audio-video operations
and the door lock release are
automatically switched at the
time of the call or with the
control switch ON.
PT5160 +
WB5100
7+(n-1)+coax
DV
9+coax
7+n+coax
PV2160 +
WB2100
1281
Mody
1382
1473
9+n+
coax
8+n
Mody
SE
SE
WITH COAX
36
(9GB-2002)
PA
PA
Si 5150
75
DV
75
PROJECT
Nn
VC n
8
1
3
1
4
9
10
11
12
13
14
2
+
out
ERREP/R
in
in
MODY
in
in
DV
9 11 12 13 14 F
F A
H 1
A
I
A
I
75
SLIM
TR
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
+
out
PUNTOVIRGOLA
230V
127V
0
AL
ErreP/R
Mody
"b"
"a"
PB
PB
PB
Nn
Nn
7
9 10 5
N1
PE
PE
4
3
2
1
N1
6
10a
9a
10b
9b
DS
4
3
2
1
ErreP/R
PE
4
3
2
1
WITHOUT COAX
Mody
"a"
8b
8a
UR
UR
1
2
7a
PA
7b
PA
SE
SE
37
(9GB-2002)
WITH COAX
H
V
M
H
V
M
A
F
MODY
ERREP/R
Description
VC
...
DV
AL
TR
DS
PA
SE
...
1
1
1
2
2
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
1281
1382
1273TV
**
**
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
2
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
2
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
2
MD82 812 MD82 812
Hood covers
2
MD92 912* MD92 912* Rain shelters
PE
2
MD30
MD30
Electric door speaker
ErreP/R series (see pages 21, 22 for the composition)
UR
PB
PE
2
2
...
2
2
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
DV
9+coax
8+coax
WITHOUT COAX
*
WITH COAX
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 6 lamps (24V-3W).
If this number is exceeded, one or more 12V
transformers and an proper power will be required (type PRS210).
- To have the control switch ON for the 2 video
entrances it is necessary to make the dashed
line connections and use WB5160, WB5660,
WB2160, WB1260 wall brackets.
- The wall brackets are configurated to work
without the audio privacy, to restore it the
jumper J1 must be moved (see pages 3, 5, 7, 9
and 10).
- In this system the control switch ON from the
monitors can interrupt a running communication, for this reason it is advisable to interrupt it
by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
For one-way systems or video kits of the
Mody series, connect the coaxial cable directly to the monitor wall bracket, without using
the DV floor video distributor.
Working instructions
It is similar to the basic system
described on page 28, but with
the following variations:
- the audio-video operations
and the door lock release are
automatically switched at the
time of the call or with the control switch ON.
PT5160 +
WB5100
7+(n-1)+coax
DV
9+coax
7+n+coax
PV2160 +
WB2100
1281
1382
9+n+
coax
Mody
SE
1273TV
9+n+
coax
SE
38
(9GB-2002)
Mody
PA
PA
Si 5250
ERREP/R
75
in
in
DV
VC n
PUNTOVIRGOLA
PROJECT
Nn
75
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
T1
+
out
in
in
DV
SLIM
9 11 12 13 14 F
H 1
A
I
A
I
230V
127V
0
AL
ErreP/R
ErreP/R
Mody
Mody
"b"
"a"
PB
Nn
9
PE
7 10 11 12 13 5
13a
12a
11a
13b
12b
11b
4
3
2
1
10b
9b
8b
H
V
M
DS
7b
PA
PA
4
3
2
1
PE
H
V
M
A
F
UR
UR
SE
SE
39
(9GB-2002)
PE
WITH COAX
UR
UR
10a
9a
8a
1
2
7a
H
V
M
H
V
M
A
F
N1
6
4
3
2
1
PB
Nn
N1
4
3
2
1
"b"
PB
WITHOUT COAX
"a"
PE
75
F A
PB
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1
+
out
TR
MODY
MODY
ERREP/R
VIDEO INTERCOM SYSTEM WITH TWO AUTOMATICALLY SWITCHED ENTRANCES, ONE WITH AN OUTDOOR
OR INDOOR SURVEILLANCE CAMERA
Description
VC
...
DV
AL
TR
DS
IN
PA
SE
...
1
1
1
1
2
2
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
1281
1382
1273TV
1471
**
**
SLIM
LL
1
1
1
1
1
1
TVT...
H...
CU...
AST..
APS...
**
Surveillance camera
Lens with or without auto-iris
Climatized housing for outside
Jointed bracket for interior or housing
Power supply for camera
Lamp with maximum power of 800W
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
2
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
2
MD82 812 MD82 812
Hood covers
2
MD92 912* MD92 912* Rain shelters
PE
2
MD30
MD30
Electric door speaker
ErreP/R series (see pages 21, 22 for the composition)
UR
PB
PE
1
2
...
2
2
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
DV
WITHOUT COAX
*
WITH COAX
Note
- The A and F terminals of article 1382 can be
connected to a maximum of 6 lamps (24V-3W).
If this number is exceeded, one or more 12V
transformers and an proper power will be required (type PRS210).
- To have the control switch ON for the 2 video
entrances it is necessary to make the dashed
line connections and use WB5160, WB5660,
WB2160, WB1260 wall brackets.
- The wall brackets are configurated to work
without the audio privacy, to restore it the
jumper J1 must be moved (see pages 3, 5, 7, 9
and 10).
- In this system the control switch ON from the
monitors can interrupt a running communication, for this reason it is advisable to interrupt it
by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the
table on page 26.
- To connect the coaxial cable see pages 26
and 27.
9+coax
8+coax
PT5160 +
WB5100
40
(9GB-2002)
7+(n-1)+coax
DV
9+coax
7+n+coax
PV2160 +
WB2100
1281
1382
9+n+
coax
Mody
SE
1273TV
T V T. . + H . . . +
C U . . . + A S T. .
+APS...
9+n+coax
Mody
SE
PA
1471
PA
Si 5256
ERREP/R
VIDEO INTERCOM SYSTEM WITH TWO AUTOMATICALLY SWITCHED ENTRANCES, ONE WITH
AN OUTDOOR OR INDOOR SURVEILLANCE CAMERA
75
in
in
DV
VC n
PUNTOVIRGOLA
PROJECT
Nn
75
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
T1
+
out
in
in
DV
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1
+
out
F A
SLIM
75
TR
9 11 12 13 14 F
H 1
MODY
A
I
A
I
230V
127V
0
AL
ErreP/R
Mody
"b"
"a"
"a"
PB
Nn
Nn
9
7 10 11 12 13 5
N1
N1
6
PE
PE
4
3
2
1
13a
12a
11a
4
3
2
1
13b
12b
11b
9b
8b
10b
LL
PE
2
3
7b
PA
PA
SE
41
(9GB-2002)
IN
3
SE
1
230V
5
6
WITH COAX
UR
UR
DS
10a
9a
8a
1
2
7a
H
V
M
H
V
M
A
F
TE
4
3
2
1
L
N
230V
PB
PB
WITHOUT COAX
ErreP/R
Mody
MODY
ERREP/R
Description
VC
...
DV
AL
TR
DS
PA
SE
...
1
1
2
3
3
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
1281
1382
1273TV
**
**
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
3
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
3
MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
3
MD82 812 MD82 812
Hood covers
3
MD92 912* MD92 912* Rain shelters
PE
3
MD30
MD30
Electric door speaker
ErreP/R series (see pages 21, 22 for the composition)
UR
PB
PE
3
3
...
3
3
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
DV
9+coax
8+coax
WITHOUT COAX
Note
- The A and F terminals of article 1382 can be connected to a
maximum of 5 lamps (24V-3W). If this number is exceeded, one or
more 12V transformers and an proper power will be required (type
PRS210).
- To have the control switch ON for the 3 video entrances it is
necessary to make the dashed line connections and use WB5160,
WB5660, WB2160, WB1260 wall brackets.
- The wall brackets are configurated to work without the audio
privacy, to restore it the jumper J1 must be moved (see pages 3, 5, 7,
9 and 10).
- In this system the control switch ON from the monitors can interrupt
a running communication, for this reason it is advisable to interrupt
it by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the table on page 26.
- To connect the coaxial cable see pages 26 and 27.
For one-way systems or video kits of the Mody series, connect the
coaxial cable directly to the monitor wall bracket, without using the
DV floor video distributor.
Working instructions
It is similar to the basic system described on page 28, but with the
following variations:
- the audio-video operations and the door lock release are automatically switched at the time of the call or with the control switch ON.
PT5160 +
WB5100
DV
9+coax
WITH COAX
42
7+n+coax
PV2160 +
WB2100
1281
9+n+
coax
Mody
1382
1273TV
9+n+
coax
Mody
SE
(9GB-2002)
7+(n-1)+coax
9+n+
coax
Mody
SE
PA
1273TV
SE
PA
PA
Si 5350
ERREP/R
75
in
in
DV
VC n
Nn
PROJECT
75
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
T1
T2
+
out
DV
VC 1
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1
P2
+
out
F A
9 11 12 13 14 F
H 1
A
I
A
I
"c"
MD
7 10 11 12 13 5
ErreP/R
MD
Nn
9
2
4
230V
127V
0
AL
Mody
1
3
SLIM
75
TR
PUNTOVIRGOLA
in
in
MODY
3
N1
4
DS
4
3
2
1
13b
12b
11b
Mody
H
V
M
H
V
M
A
F
UR
PA
PE
UR
SE
"a"
Mody
"a"
PB
PB
PE
7 10 11 12 13 5
13a
12a
11a
13b
12b
11b
4
3
2
1
10b
9b
8b
H
V
M
DS
7b
PA
SE
43
(9GB-2002)
4
3
2
1
PE
H
V
M
A
F
UR
PA
SE
PE
UR
WITH COAX
UR
UR
10a
9a
8a
1
2
7a
H
V
M
H
V
M
A
F
N1
6
4
3
2
1
PB
Nn
8
N1
4
3
2
1
ErreP/R
PB
Nn
9
PE
"b"
WITHOUT COAX
10b
9b
8b
1
2
ErreP/R
4
3
2
1
PE
MODY
Multi-way systems
Si 5550
ERREP/R
MULTI-WAY VIDEO-INTERCOM SYSTEM WITH AUXILIARY AUDIO ENTRANCES AND ONE MAIN VIDEO
ENTRANCE ACCORDING TO THE STAIRWAY
Description
VC
...
DV
AV
AL
TR
DS
PA
SE
...
1
1+X
1+X
X
1+X
1+X
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
476
1281
1382
1273TV
**
**
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1
MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
1+X MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
1+X MD82 812 MD82 812
Hood covers
1+X MD92 912* MD92 912* Rain shelters
PE
1+X MD30
MD30
Electric door speaker
The push-button panel of the main video entrance must have separate commons. A common for every auxiliary entrance. The buttons of
Mody series can be divided in groups of 2.
PE
1
1+X
...
1+X
1+X
1385R
RP...
R...
290R/2 290R/38
337C
common buttons 1
and 2
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
to separate buttons
common cut here
common buttons 3
and 4
"a"
"b"
DV
DV
9+coax
9+coax
8+coax
PT5160 +
WB5100
WITHOUT COAX
Working instructions
It is similar to the basic system described on page 28, but with the
following variations:
- the audio-video operations and the door lock release are
automatically switched at the time of the call or with the control
switch ON.
- Carrying out a call from the entrance only audio, the corresponding monitor turns itself ON without images.
- The services towards the auxiliary audio entrances are independent among themselves and therefore they can function at
the same time.
8+coax
PV 1260
+ 1283
7+(n-1)
+coax
7+(n-1)
+coax
DV
DV
9+coax
9+coax
1281
1382
1273TV
7+n+coax
Mody
8+n
PT5660+WB5600+1283
PT5860+WB5600
1281
WITH COAX
Note
The 75 resistance inserted between terminals 1 and 3 of
monitors is supplied with the product. It is not to be added.
- The A and F terminals of article 1382 can be connected to a
maximum of 5 lamps (24V-3W). If this number is exceeded, one
or more 12V transformers and an proper power will be required
(type PRS210).
- In this system the control switch ON from the monitors can
interrupt a running communication, for this reason it is advisable
to interrupt it by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the table on page 26.
- To connect the coaxial cable see pages 26 and 27.
7+n+coax
PV 2160 +
WB 2100
Mody
SE
1273TV
8+n
8+n+
coax
PA
1382
SE
8+n+
coax
PA
Mody
8+X+n
+coax
7+(X-1)+
n+coax
"p"
9+coax
2
44
(9GB-2002)
SE
PA
1281
1382
476
7+(X-2)+
n+coax
Si 5550
"A"
75
"B"
75
+
out
DV
VC n
in
75
in
DV
in
75
in
VC 1
N1 (a)
AL
A
I
230V
127V
0
A
I
11 14 13 12 4
F A S H
AL
TR
in
in
N1 (b)
A
I
230V
127V
0
9 3 2 1 D
+
out
8
1
3
1
2
4
9
10
11
12
13
14
P1
A
I
11 14 13 12 4
F A S H
PUNTOVIRGOLA* SLIM
+
out
8
1
3
1
2
4
9
10
11
12
13
14
P1
in
75
in
Nn (b)
DV
VC 1
DV
PROJECT
Nn (a)
75
+
out
8
1
3
1
2
4
9
10
11
12
13
14
T1
8
1
3
1
2
4
9
10
11
12
13
14
T1
ERREP/R
MULTI-WAY VIDEO-INTERCOM SYSTEM WITH AUXILIARY AUDIO ENTRANCES AND ONE MAIN VIDEO
ENTRANCE ACCORDING TO THE STAIRWAY
VC n
MODY
Multi-way systems
TR
9 3 2 1 D
(b)
(a)
PB
PB
Nn (a)
Nn (b)
N1 (a)
N1 (b)
4 7b 13 12 11 3
PE
4
3
2
1
7 8 9 10
4 7b 13 12 11 3
PE
13b
12b
11b
DS
4
3
2
1
13b
12b
11b
10b
9b
8b
1
2
DS
10b
9b
8b
1
2
5 8a 9a
PA
SE
7 8 9 10
5 8a 9a
PA
SE
WITHOUT COAX
(p)
OUT 2
Nn (a)
OUT
OUT 3
AV
N1 (a)
PB
IN
OUT 4
14
Nn (b)
N1 (b)
PE
4
3
2
1
H
V
M
PA
SE
S
11 2
TR
A
I
F
A
I
45
(9GB-2002)
AL
230V
127V
0
WITH COAX
UR
MODY
Multi-way systems
Si 5551
ERREP/R
MULTI-WAY VIDEO-INTERCOM SYSTEM WITH AUXILIARY VIDEO ENTRANCES AND ONE MAIN VIDEO
ENTRANCE ACCORDING TO THE STAIRWAY
Description
VC
...
DV
AV
AL
TR
DS
PA
SE
...
1
1+X
1+X
X
1+X
1+X
PROJECT
*
PUNTOVIRGOLA
PT 5160 + WB 5100
PT 5660 + WB 5600 + 1283
PT 5860 + WB 5600
PV 1260 + WB1200 + 1283
PV 2160 + WB 2100
DV2-4
476
1281
1382
1273TV
**
**
SLIM
Mody series (see pages 16, 17, 18, 19 for the composition)
1 row
2 row
UR
1 +X MD41
MD41
Camera module
PB
...
MD72-73-74 MD72-73-74
Module frames and with back box
1+X MD10-11-12 MD10-122-124 Modules for electric door speaker
...
MD21 24
MD222 228 Button modules
...
MD20 - 50
MD20 - 50
Blank and number modules
1+X MD82 812 MD82 812
Hood covers
1+X MD92 912* MD92 912* Rain shelters
PE
1+X MD30
MD30
Electric door speaker
The push-button panel of the main video entrance must have separate commons. A common for every auxiliary entrance. The buttons of
Mody series can be divided in groups of 2.
common buttons 1
and 2
UR
PB
to separate buttons
common cut here
PE
1+X
1+X
...
1+X
1+X
1385R
RP...
R...
290R/2 290R/38
337C
Camera unit
Push-button panel
Push-button panel
Rain shelters
Electric door speaker
common buttons 3
and 4
"a"
"b"
DV
DV
9+coax
9+coax
8+coax
PT5160 +
WB5100
WITHOUT COAX
Working instructions
It is similar to the basic system described on page 28, but with the
following variations:
- The audio-video operations and the door lock release are
automatically switched at the time of the call or with the control
switch ON.
- The services towards the auxiliary video entrances are independent among themselves and therefore they can function at the same
time.
8+coax
PV 1260
+ 1283
7+(n-1)
+coax
7+(n-1)
+coax
DV
DV
9+coax
9+coax
7+n+coax
1281
1382
Mody
Mody
1273TV
9+n+
coax
PT5660+WB5600+1283
PT5860+WB5600
1281
2
4
7+n+coax
PV 2160 +
WB 2100
WITH COAX
Note
The 75 resistance inserted between terminals 1 and 3 of
monitors is supplied with the product. It is not to be added.
- The A and F terminals of article 1382 can be connected to a
maximum of 6 lamps (24V-3W). If this number is exceeded, one or
more 12V transformers and an proper power will be required (type
PRS210).
- To have the control switch ON for the 3 video entrances it is
necessary to make the dashed line connections and use WB5160,
WB5660, WB2160, WB1260 wall brackets.
- The wall brackets are configurated to work without the audio
privacy, to restore it the jumper J1 must be moved (see pages 3, 5,
7, 9 and 10).
- In this system the control switch ON from the monitors can
interrupt a running communication, for this reason it is advisable to
interrupt it by means of a relay art.1471 (see page 24).
- For the cross section of the wires see the table on page 26.
- To connect the coaxial cable see pages 26 and 27.
1
3
SE
1273TV
9+n+
coax
8+n+
coax
PA
1382
SE
8+n+
coax
PA
Mody
8+X+n
+coax
7+(X-1)+
n+coax
"p"
9+coax
2
46
(9GB-2002)
SE
PA
1281
1382
476
7+(X-2)+
n+coax
Si 5551
"A"
75
"B"
75
+
out
DV
VC n
in
75
in
DV
8
1
3
1
2
4
9
10
11
12
13
14
P1
in
in
75
VC 1
N1 (a)
+
out
8
1
3
1
2
4
9
10
11
12
13
14
P1
in
in
N1 (b)
PUNTOVIRGOLA
+
out
75
in
in
Nn (b)
DV
VC 1
DV
PROJECT
Nn (a)
75
+
out
8
1
3
1
2
4
9
10
11
12
13
14
T1
8
1
3
1
2
4
9
10
11
12
13
14
T1
ERREP/R
MULTI-WAY VIDEO-INTERCOM SYSTEM WITH AUXILIARY VIDEO ENTRANCES AND ONE MAIN VIDEO
ENTRANCE ACCORDING TO THE STAIRWAY
VC n
MODY
Multi-way systems
AL
A
I
230V
127V
0
A
I
11 14 13 12 4
F A S H
AL
TR
SLIM
1
3
A
I
230V
127V
0
9 3 2 1 D
A
I
11 14 13 12 4
F A S H
TR
9 3 2 1 D
(b)
(a)
PB
PB
Nn (a)
Nn (b)
N1 (a)
N1 (b)
4 7b 13 12 11 3
PE
4
3
2
1
4 7b 13 12 11 3
7 8 9 10
PE
13b
12b
11b
DS
10b
9b
8b
1
2
H
V
M
UR
13b
12b
11b
DS
10b
9b
8b
1
2
H
V
M
UR
5 8a 9a
PA
SE
4
3
2
1
7 8 9 10
5 8a 9a
PA
SE
WITHOUT COAX
(p)
OUT 2
Nn (a)
OUT
OUT 3
AV
N1 (a)
PB
IN
OUT 4
14
Nn (b)
N1 (b)
PE
4
3
2
1
H
V
M
PA
SE
S
11 2
TR
A
I
F
A
I
47
(9GB-2002)
AL
230V
127V
0
WITH COAX
UR
MODY
Working diagrams
ERREP/R
PROJECT
*
PUNTOVIRGOLA
SLIM
To P3 terminal
To the terminal I
of art.1382
WITHOUT COAX
*
WITH COAX
48
(9GB-2002)
MODY
Working diagrams
SLIM
PUNTOVIRGOLA
PROJECT
ERREP/R
FLOOR CALL
VC
8
1
3
1
4
9
10
11
12
13
14
2
X2
X1
Floor push-button
VC
Floor push-button
8
1
3
1
4
9
10
11
12
13
14
2
X2
X1
WITHOUT COAX
Notes
Floor calls are available in videointercom installations
with coaxial cable. To provide the service, you must use
wall-mounting brackets (WB5160, WB5660, WB2160
or WB1260), add a wire in the riser and connect the floor
button as shown in the enclosed diagram.
A continuous tone different from the external push-button
panel modulated tone is generated when pressing the
floor button.
In installations with intercommunication service the same
continuous tone is used for floor and intercom calls.
WITH COAX
49
(9GB-2002)
MODY
Working diagrams
ERREP/R
PROJECT
*
Terminal A
(art.1382)
PUNTOVIRGOLA
VC1
VC2
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
X2
VC =PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
75
or, if intercommunicating
VC =PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
P1-T1
Terminal I
(art.1382)
I
A +
AL
2
4
SLIM
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
1
3
1281
127V
230V
WITHOUT COAX
VC1
VC2
VC3
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
X2
P2-T2
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
X2
75
VC =PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
or, if intercommunicating
VC =PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
P1-T1
Terminal I
(art.1382)
I
A +
AL
1281
1
0
127V
230V
WITH COAX
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
50
(9GB-2002)
MODY
Working diagrams
ERREP/R
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
P3-T3
P4-T4
1 3 5 6
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
X2
P2-T2
P3-T3
P4-T4
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
X2
P3-T3
P4-T4
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
P3-T3
X2
P4-T4
75
PUNTOVIRGOLA
VC3
VC2
PROJECT
IN 1471
VC1
P1-T1
Terminal I
(art.1382)
1281
A +
AL
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
A +
AL
0
127V
230V
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
SLIM
127V
230V
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
1281
*
IN 1471
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
P3-T3
P4-T4
1 3 5 6
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
X2
P2-T2
P3-T3
P4-T4
VC3
VC4
VC5
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
X2
P3-T3
P4-T4
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
P3-T3
X2
P4-T4
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
P3-T3
P4-T4
X2
P1-T1
1281
1281
A +
AL
0
127V
230V
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
51
(9GB-2002)
A +
AL
0
127V
230V
WITH COAX
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
75
VC2
WITHOUT COAX
Terminal I
(art.1382)
VC1
MODY
Working diagrams
ERREP/R
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
PROJECT
Terminal A
(art.1382)
PUNTOVIRGOLA
CT1
75
5
6
3
1
2
7
X1
P1
X2
CT =
PT510
PV100
924
SR40
or, if intercommunicating
PT520 + SR40 + PT501
P1-T1
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
SLIM
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
In all intercoms cut the W1 jumper which links the terminals
3 and 7. Then apply the electronic bell SR40.
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
*
VC
WITHOUT COAX
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
Terminal A
(art.1382)
CT1
75
CT2
5
6
3
1
2
5
6
3
1
2
7
X1
P1
X2
P2
7
X1
P1
P2
X2
CT =
PT510
PV100
924
SR40
or, if intercommunicating
PT520 + SR40 + PT501
P1-T1
WITH COAX
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
In all intercoms cut the W1 jumper which links the terminals
3 and 7. Then apply the electronic bell SR40 and the button
groups.
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
9 7
6 3 2 1 5 P1
P2
PT520
P3
Note
In all the intercommunicating intercoms, connect one of the two terminals of the single
button group to terminal 7.
52
(9GB-2002)
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
MODY
Working diagrams
ERREP/R
*
75
2
4
5
6
3
1
2
5
6
3
1
2
5
6
3
1
2
7
X1
P1
X2
P2
P3
7
X1
P1
P2
X2
P3
7
X1
P1
P2
P3
X2
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
SR40
SLIM
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
In all intercoms cut the W1 jumper which links the terminals
3 and 7. Then apply the electronic bell SR40 and the button
groups.
CT3
1
3
P1-T1
CT2
PUNTOVIRGOLA
Terminal A
(art.1382)
CT1
1 3 5 6
PROJECT
IN 1471
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
P3-T3
VC
9 7
6 3 2 1 5 P1
P2
PT520
P3
Note
In all the intercommunicating intercoms, connect one of the two terminals of the single
button group to terminal 7.
*
IN 1471
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
P3-T3
P4-T4
1 3 5 6
75
Terminal A
(art.1382)
P1-T1
CT2
CT4
CT3
5
6
3
1
2
5
6
3
1
2
5
6
3
1
2
5
6
3
1
2
7
X1
P1
X2
P2
P3
P4
7
X1
P1
P2
X2
P3
P4
7
X1
P1
P2
P3
X2
P4
7
X1
P1
P2
P3
P4
X2
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
53
(9GB-2002)
9 7
6 3 2 1 5 P1
P2
PT520
P3
Note
In all the intercommunicating intercoms, connect one of the two terminals of the single
button group to terminal 7.
WITH COAX
SR40
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
To have the intercommunicating service, make the connections which have been drawn with a dashed line, then
insert in the timer, art.1382, the module for intercommunicating, art.1443E, which is included in the video kit (see
page 23).
In all intercoms cut the W1 jumper which links the terminals
3 and 7. Then apply the electronic bell SR40 and the button
groups.
CT1
WITHOUT COAX
VC
MODY
Working diagrams
ERREP/R
VC1
VC2
VC3
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
X2
P2-T2
8
1
3
1
4
9
10
11
12
13
14
2
X1
P1-T1
P2-T2
X2
PROJECT
75
VC =PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
PUNTOVIRGOLA
or, if intercommunicating
VC =PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
P1-T1
2 5 3 6
A +
SLIM
2443
AL
1471 IN
SA
1281
1
0
127V
230V
ADDITIONAL DIAGRAM FOR MULTI-WAY SYSTEMS WITH 1 MONITOR AND 2 PARALLEL INTERCOMS
*
VC
WITHOUT COAX
8
1
3
1
4
9
10
11
12
13
14
2
X1
X2
P1-T1
P2-T2
13a 12a 12 13 14 O F B
2443
CT1
75
+
AL
SA
CT2
5
6
3
1
2
5
6
3
1
2
7
X1
P1
X2
P2
7
X1
P1
P2
X2
CT =
PT510
PV100
924
SR40
9 7
6 3 2 1 5 P1
PRS231
P2
PT520
127V
230V
WITH COAX
P1-T1
P3
Note
In all the intercommunicating intercoms, connect one of the two terminals of the single
button group to terminal 7.
In all intercoms cut the W1 jumper which links the
terminals 3 and 7. Then apply the electronic bell
SR40 and the button groups.
54
(9GB-2002)
or, if intercommunicating
PT520 + SR40 + PT501
VC =
PT5160 + WB5100
PT5660 + WB5600 + 1283
PT5860 + WB5600
PV2160 + WB2100
PV1260 + WB1200 + 1283
or, if intercommunicating
PT5160 + WB5160
PT5660 + WB5660 + 1283
PT5860 + WB5660
PV2160 + WB2160
PV1260 + WB1260 + 1283
MODY
PEP
1S
3 9 /16"
ANTILOCALE
19
3
Lamp terminals
Button terminal board
Call buttons common (terminal C)
Stair light button terminals
External volume adjustment
Feedback adjustment
Terminal board for audio/powering/elect. lock
124
4 7 /8"
52
2 1 /16"
90
3 9 /16"
/4"
-10+40C
80%RH
Terminals
Y positive video signal output
F ground
X negative video signal output
H positive power supply input 21Vdc
Volume adjustment
To increase the volume from the amplifier in
the transmission mode, turn the trimmer
in a clockwise direction.
Sweeps
If necessary, you can manually change the camera framing by unloosening and adjusting the
horizontal or vertical screw in the desired direction
(or both screws if you want to adjust the image in
all directions).
PEP
PEP
Antilocale adjustment
In case of "feeback" (Larsen effect) in the
external unit it is necessary to operate as
follow:
- make the call from the door station and lift
the handset of an intercom;
- adjust the trimmer antilocale until the whistling stops (Larsen effect).
WITHOUT COAX
2 lux
291000
15625Hz
50/60Hz
3.6mm; F5
0,1m
Y
F
X
H
PEP
4.75.C091.01
213Vdc
0.3A
PEP
19
Technical data
Power supply
Operating current
Output of balanced video signal
Minimum illumination
Pixel number
Horizontal frequency
Vertical frequency
Lens
Adjustable focus
Opening of auto-iris
Operating temperature
Maximum permissible humidity
SLIM
PUNTOVIRGOLA
1
2
3
4
5
6
7
/4"
MD 41D.
Camera module for 4+1 video systems without
coaxial cable, including:
- solid-state CCD camera, with auto iris, 3.6mm
fixed optics and 6 infrared LEDs;
- front plate in anodized aluminium with breakproof transparent screen;
- horizontal/vertical sweep.
PROJECT
90
Mody series .
To plan a 4+1 video intercom system all the
button modules can be used, as well as the
back boxes, the protective shelters and the
decorative shields which have been described
on pages 12 to 19. Only the CCD camera
MD41 and the modules MD10, MD11 and
MD12 are several, in that they have been
adapted for functioning with a reduced number of wires (ref. MD41D, MD10ED, MD11ED,
and MD12ED).
52
2 1 /16"
4 7 /8"
ERREP/R
124
3
PUSH-BUTTON PANELS
CAMERAS
The products of this line allow for the realization of a system with 4 common wires for all
monitors, and one for each user, without
using the coaxial cable.
It is possible to receive a call from any monitor, from the external station, it is possible to
see, communicate with the caller and release
the electric door lock.
horizontal
55
(9GB-2002)
WITH COAX
vertical
MODY
1 row push-button
ERREP/R
*
PROJECT
1 call button
2 call buttons
3 call buttons
4 call buttons
5 call buttons
6 call buttons
7 call buttons
PUNTOVIRGOLA
50
7 call buttons
8 call buttons
9 call buttons
10 call buttons
50
50
12 call buttons
14 call buttons
23 call buttons
24 call buttons
26 call buttons
11 call buttons
SLIM
16 call buttons
18 call buttons
50
50
19 call buttons
21 call buttons
50
27 call buttons
50
WITHOUT COAX
28 call buttons
30 call buttons
32 call buttons
34 call buttons
37 call buttons
38 call buttons
40 call buttons
42 call buttons
50
35 call buttons
50
WITH COAX
43 call buttons
50
45 call buttons
48 call buttons
56
(9GB-2002)
50 call buttons
1 row push-button
Composition board of Mody push-button panels.
MODY
Rain
shelter
1 MD72
1 MD82
1 MD92
1 MD72
1 MD82
1 MD92
ERREP/R
1 MD73
1 MD83
1 MD93
1 MD73
1 MD83
1 MD93
1 MD73
1 MD83
1 MD93
1 MD24
1 MD73
1 MD83
1 MD93
4 241D
1 MD24
1 MD23
2 MD72
1 MD84
1 MD94
PROJECT
4 241D
2 MD24
2 MD72
1 MD84
1 MD94
1 MD11ED
4 241D
2 MD24
2 MD72
1 MD84
1 MD94
1 MD41D
1 MD12ED
4 241D
2 MD24
2 MD72
1 MD84
1 MD94
11
1 MD41D
1 MD10ED
6 241D
2 MD24
1 MD23
2 MD73
1 MD86
1 MD96
12
1 MD41D
1 MD10ED
6 241D
3 MD24
2 MD73
1 MD86
1 MD96
13
1 MD41D
1 MD11ED
6 241D
3 MD24
2 MD73
1 MD86
1 MD96
14
1 MD41D
1 MD12ED
6 241D
3 MD24
2 MD73
1 MD86
1 MD96
15
1 MD41D
1 MD10ED
8 241D
3 MD24
1 MD23
2 MD73
1 MD86
1 MD96
PUNTOVIRGOLA
1 MD41D
1 MD10ED
8 241D
4 MD24
2 MD73
1 MD86
1 MD96
1 MD41D
1 MD11ED
8 241D
4 MD24
2 MD73
1 MD86
1 MD96
1 MD41D
1 MD12ED
8 241D
4 MD24
2 MD73
1 MD86
1 MD96
SLIM
19
1 MD41D
1 MD10ED
10 241D
4 MD24
1 MD23
2 MD74
1 MD808
1 MD908
20
1 MD41D
1 MD10ED
10 241D
5 MD24
2 MD74
1 MD808
1 MD908
21
1 MD41D
1 MD11ED
10 241D
5 MD24
2 MD74
1 MD808
1 MD908
22
1 MD41D
1 MD12ED
10 241D
5 MD24
2 MD74
1 MD808
1 MD908
23
1 MD41D
1 MD12ED
11 241D
5 MD24
1 MD21
2 MD74
1 MD808
1 MD908
1 MD41D
1 MD12ED
11 241D
5 MD24
1 MD22
2 MD74
1 MD808
1 MD908
1 MD41D
1 MD12ED
12 241D
5 MD24
1 MD23
2 MD74
1 MD808
1 MD908
1 MD41D
1 MD12ED
12 241D
6 MD24
2 MD74
1 MD808
1 MD908
1 MD41D
1 MD11ED
14 241D
5 MD24
2 MD23
3 MD73
1 MD89
1 MD99
1 MD41D
1 MD10ED
14 241D
7 MD24
3 MD73
1 MD89
1 MD99
1 MD41D
1 MD11ED
14 241D
7 MD24
3 MD73
1 MD89
1 MD99
30
1 MD41D
1 MD12ED
14 241D
7 MD24
3 MD73
1 MD89
1 MD99
31
1 MD41D
1 MD11ED
16 241D
6 MD24
2 MD23
3 MD74
1 MD812
1 MD912
32
1 MD41D
1 MD12ED
16 241D
6 MD24
2 MD23
3 MD74
1 MD812
1 MD912
33
1 MD41D
1 MD11ED
16 241D
8 MD24
3 MD74
1 MD812
1 MD912
34
1 MD41D
1 MD12ED
16 241D
8 MD24
3 MD74
1 MD812
1 MD912
35
1 MD41D
1 MD12ED
17 241D
8 MD24
1 MD21
3 MD74
1 MD812
1 MD912
36
1 MD41D
1 MD12ED
18 241D
8 MD24
2 MD21
3 MD74
1 MD812
1 MD912
1 MD41D
1 MD11ED
18 241D
8 MD24
2 MD22
3 MD74
1 MD812
1 MD912
1 MD41D
1 MD12ED
18 241D
8 MD24
2 MD22
3 MD74
1 MD812
1 MD912
39
1 MD41D
1 MD11ED
20 241D
8 MD24
2 MD23
3 MD74
1 MD812
1 MD912
40
1 MD41D
1 MD12ED
20 241D
8 MD24
2 MD23
3 MD74
1 MD812
1 MD912
41
1 MD41D
1 MD12ED
20 241D
9 MD24
1 MD23
3 MD74
1 MD812
1 MD912
42
1 MD41D
1 MD12ED
20 241D
10 MD24
3 MD74
1 MD812
1 MD912
43
1 MD41D
1 MD12ED
22 241D
8 MD24
3 MD23
4 MD74
44
1 MD41D
1 MD10ED
22 241D
11 MD24
4 MD74
45
1 MD41D
1 MD11ED
22 241D
11 MD24
4 MD74
46
1 MD41D
1 MD12ED
22 241D
11 MD24
4 MD74
47
1 MD41D
1 MD10ED
25 241D
11 MD24
3 MD21
4 MD74
1 MD41D
1 MD11ED
25 241D
11 MD24
3 MD21
4 MD74
1 MD41D
1 MD12ED
25 241D
11 MD24
3 MD21
4 MD74
1 MD41D
1 MD10ED
25 241D
11 MD24
3 MD22
4 MD74
Camera
module
Module with
speaker
2 diode
module
1 MD41D
1 MD11ED
1 MD41D
1 MD12ED
1 MD41D
1 MD10ED
2 241D
1 MD23
1 MD41D
1 MD10ED
2 241D
1 MD24
1 MD41D
1 MD11ED
2 241D
1 MD24
1 MD41D
1 MD12ED
2 241D
1 MD41D
1 MD10ED
1 MD41D
1 MD10ED
1 MD41D
1
2
10
Compositions and
dimensions
124x213x19
(47/8"x 83/8"x 3/4")
124x304.5x19
(4 7/8" x 12" x 3/4")
248x213x19
(9 /4" x 8 3/8" x 3/4")
3
16
17
18
248x304.5x19
(9 3/4" x 12" x 3/4")
24
25
26
248x395x19
(9 3/4" x 15 9/16" x 3/4")
27
28
29
37
38
50
496x395x19
(19 1/2" x 15 9/16" x 3/4")
57
(9GB-2002)
Optional
It replaces
MD72, 73, 74
WITH COAX
49
372x395x19
(14 5/8" x 15 9/16" x 3/4")
48
372x304.5x19
(14 5/8" x 12" x 3/4")
WITHOUT COAX
Hood
covers
N
calls
MODY
89
215.5
3 1/2"
8 1/2"
J2
ERREP/R
PROJECT
215
J3
8 7/16"
PUNTOVIRGOLA
SLIM
PT5111E. Two-colour flat monitor with two buttons, one for control
switch ON and one for door lock release, audio-video privacy, electronic
microphone, electronic modulated call note, terminal board for the
connection to the wall-bracket. It can be installed on the wall (with no builtin) by using the art.WB5111E.
PT5111EW. Colour: white.
WB5111E. Wall-bracket for the PT5111E and PT5111EW monitors.
It includes a terminal board for connection to the system.
Technical data
Power Supply
Operating current
Video tube
Television standard
Horizontal frequency
Vertical frequency
Bandwidth
Balanced video signal
Starting up time
Operating temperature
Max. permissible humidity
1824Vdc
0.35A
4" FLAT CRT
625 lines
15625Hz
50Hz
>5MHz
24 sec.
0+50C
90%RH
Terminals
H
Positive power supply input 1824Vdc-0.35A
F
Ground
X and Y
Video signal input
10
Call, audio reception/transmission,
door releasing
4
Control switch ON - button
WITHOUT COAX
83.5
3 5/16"
43
1 11/16"
U
P
40.5
1 5/ "
Audio privacy
122
4 13/16"
1-2
140 150 cm
4" 7" 4" 11"
J1
1 2 3
X
Y
A1
F
F
H
10
4
WITH COAX
1 2 3
J1
2-3
1 2 3
aaaaaaaaaaaa
58
(9GB-2002)
J1
MODY
PUNTOVIRGOLA
Note
- The power supply is not provided with fuses,
but all of its outputs are protected against overloading and short circuiting by temperature
sensors. To reset the power supply, pow-er
must be cut off for about one minute and can be
restored after having eliminated the defect.
- The power supply must be installed in a dry
place and can be fixed on DIN bar or on a wall
by using the expansion plugs.
89
3 1/2 "
PROJECT
140
5 1/2 "
Terminals
74
2 15/16"
Technical data
Input voltage
127 or 230Vac
Frequency
50/60Hz
Power
48VA
Switch-ON time:
100 sec.
Operating temperature
040C
Maximum permissible humidity 90%RH
Housing
DIN 8 modules A
Weight
0.95Kg.
ERREP/R
Power supply
SLIM
65
2 9 /16"
70
89
2 3 /4"
3 1 /2"
RL37D.
When installed in 1+1 intercom and 4+1 video
intercom systems with electronic call, it provides a supplementary input for external calls,
enables supplementary video power supply
and provide a second ringer for floor calls.
Technical data
Power supply:
Stand-by current:
Max. switching current:
Housing:
Operating temperature:
Max. permissible humidity:
13Vac
40mA
1A (24V)
DIN 4 A modules
0 50C
90% RH
Terminals
A 13Vac alternate voltage input
ground
H timed positive continuous voltage input 21Vdc
IV supplementary power supply enabling
C common contact of relay
NA normally open contact of relay
NC normally closed contact of relay
1P electronic call input
1M electronic call output enabled from terminal
1P
CP electronic call output
IV
H
A
CP
1P
1M
NC
NA
C
122
4 13/16"
25
1"
68
2 11/16"
to following distributors
to monitor
to monitor
X3 Y 3 H F
F H Y X
F H Y2 X2
X4 Y 4 H F
F H Y X
F H Y1 X1
Terminals
H
Input / output positive power supply
F
Ground
X and Y Input / output video signal
Note
The two 75 resistors, included with the product, must be applied to connectors Y-F and XF on the last distributor only.
Leave other terminals free.
59
(9GB-2002)
to monitor
to monitor
from previous distributors
WITH COAX
212Vdc
60mA
2Vpp
0.8dB
>5MHz
Technical data
Power supply
Operating current
Max input video signal
Insertion loss
Bandwidth
WITHOUT COAX
Floor distributors
MODY
ERREP/R
Installation rules
Working instructions
PROJECT
*
PUNTOVIRGOLA
Wires
SLIM
1) You must select the correct type of cable to ensure the correct operation of
videointercom installations.
2) Wires must be dimensioned according to the distance between the devices and
according to their consumption.
3) Do not use multiple wires in parallel to reach the requested cross-section (for
example multipair telephone cables). Use a single wire with suitable cross-section.
In case of multicore cables use cables with low parasite parameters (low capacity
per metre, low inductance over Ohm).
4) If the installation includes additional power supplies, place them near the devices to
be powered.
Background noise
To avoid background noise over the voice line, it is recommended:
1) not to use the same cable channel for intercom cables and wires with AC loads;
2) to avoid using the same multicore cable for the transmission of voice signals and for
AC power supplies (lamps, amplified external stations, electrical locks). Always use
separate wires for AC power supplies;
3) for name plate lighting use a 12V additional transformer (PRS210 type) with suitable
capacity (consumption is 75mA for each lamp), keeping the 2 power supply wires
separate from the voice wires
4) the power supply must be positioned near the external door station in case of a long
distance between the external door station and the last videointercom.
WITHOUT COAX
Diagram 50m
lines
S mm
165 Ft
100m
330 Ft
200m
660 Ft
AWG
S mm
AWG
S mm
AWG
X-Y
0.35
22
0.35
22
0.35
22
10 - 4 - 1 - C-
0.5
20
0.75
18
16
F-H-A-S-
0.75
18
16
14
If the distance between the camera and the last videointercom is lower than 200 metres,
two 0.5mm (=0,5mm) wires can be used for video connection instead of coaxial
cable. A twisted pair must be used for 100m to 200m distances.
*
X
Y
X
Y
WITH COAX
60
(9GB-2002)
Si 411R/1
MODY
ERREP/R
PROJECT
*
PUNTOVIRGOLA
*
SLIM
WITHOUT COAX
*
61
(9GB-2002)
WITH COAX
Note
In all the 4+1 video intercom systems it is possible to add further monitors and/or intercoms. To do this, insert the 2 application examples in this page instead
of the monitor which has been represented in the various installation systems of pages 61, 62, 63 and 64.
MODY
ERREP/R
PROJECT
*
PUNTOVIRGOLA
*
SLIM
Conversation privacy
In case of conversation privacy function, jumper
W1 of the intercom and resistance R1 of module SM50 must be cut.
WITHOUT COAX
*
WITH COAX
62
(9GB-2002)
Si 42MR/1
MODY
ERREP/R
X1
Y1
H
F
Xn
F
PROJECT
DV2D
DV4D
X
Y
H
F
10
4
PT5111E
WB5111E
PUNTOVIRGOLA
X1
Y1
H
F
X
Y
H
F
10
4
SLIM
DV2D
DV4D
Y
PT5111E
WB5111E
PRS210
1181E
X2
X2
X3
Xn
MD2..
P
MD2..
241D
C
E
P
C
MD7.
MD10ED
MD11ED
MD12ED
10b
P
C
E
1
2
9
3
5
6
10
10a
A
S
MD7.
MD10ED
MD11ED
MD12ED
A
S
1473
9b
8b
7b
SE (12Vac-1A max.)
F
H
X
Y
9a
8a
7a
63
(9GB-2002)
MD41D
WITH COAX
PA
(optional)
PA
(optional)
SE (12Vac-1A max.)
WITHOUT COAX
X3
230V
127V
0
230V
127V
0
Xn
MODY
ERREP/R
PROJECT
DV2D
DV4D
Y
H
X1
Y1
H
F
X
Y
H
F
10
4
Xn
F
PT5111E
WB5111E
PUNTOVIRGOLA
SLIM
DV2D
DV4D
Y
H
X1
Y1
H
F
X
Y
H
F
10
4
PT5111E
WB5111E
PRS210
1181E
X3
230V
127V
0
230V
127V
0
WITHOUT COAX
Xn
X2
X2
X3
Xn
MD2..
P
MD2..
241D
C
E
P
C
MD7.
MD10ED
MD11ED
MD12ED
10b
1
2
9
3
5
6
10
P
C
E
1
10a
A
S
WITH COAX
PA
(optional)
PA
(optional)
1473
SE (12Vac-1A max.)
MD41D
F
H
X
Y
MD7.
MD10ED
MD11ED
MD12ED
A
S
9b
8b
7b
SE (12Vac-1A max.)
F
H
X
Y
9a
8a
7a
64
(9GB-2002)
MD41D
PRODUCT LIST
List of articles that can be used in videointercom installations with page reference.
Description
Page ref.
Page ref.
Diode module
Timed power supply
2-output video distributor
4-output video distributor
Amplified door station module without push-buttons
Amplified door station module with 1 push-button
Amplified door station module with 2 push-buttons
Camera module
Camera module
Bicolour Flat monitor Project series
White Flat monitor Project series
Module for supplementary calls
Wall bracket for PT5111E and PT5111EW monitors
31
2
2
31
31
4
31
6
31
6
31
10
31
31
8
31
8
21
21
21
21
21
21
21
21
21
21
21
21
21
34
11
3
25
10
10
8
8
2
2
4
4
55
55
59
59
59
55
55
55
55
55
58
58
59
58
WITH COAX
21
27
24
23
5
31
23
21
23
24
24
24
26
26
20
13
13
13
13
13
13
13
13
13
20
20
20
20
13
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
20
13
13
20
13
13
13
13
23
11
11
11
11
11
11
11
31
31
31
2
31
31
Description
WITHOUT COAX
337C
Electric door-speaker for ErreP/R push-button panel
476
5-output video distributor
1273TV
7-exchange switcher
1281
Video power supply
1283
Back-box for PT5660 and PV1260 monitors
1304
Videointercom cable with 10 wires + coaxial
1382
Audio-video timer
1385R
Camera unit ErreP/R series
1443E
Intercommunicanting module
1471
Relay unit
1473
4-exchange exchanger
2443
Audio-relay amplifier
DV2
2-output video distributor
DV4
4-output video distributor
FC52P
Access control keypad
MD10
Module for door speaker without push-buttons
MD11
Module for door speaker with 1 push-button
MD12
Module for door speaker with 2 push-buttons
MD20
Blank module
MD21
Button module with 1 push-button
MD22
Button module with 2 push-buttons
MD23
Button module with 3 push-buttons
MD24
Button module with 4 push-buttons
MD30
Electric door speaker
MD40
Camera module
MD40C
Colour camera module
MD41
Camera module
MD41C
Colour camera module
MD50
Street number module
MD71
Back box with frames for 1 module
MD72
Back box with frames for 2 modules
MD73
Back box with frames for 2 modules
MD74
Back box with frames for 2 modules
MD81
Hood cover for 1 module
MD82
Hood cover for 2 modules
MD83
Hood cover for 3 modules
MD84
Hood cover for 4 modules (2 frames with 2 modules)
MD804
Hood cover for 4 modules (1 frame with 4 modules)
MD86
Hood cover for 6 modules (2 frames with 3 modules)
MD808
Hood cover for 8 modules (2 frames with 4 modules)
MD89
Hood cover for 9 modules (3 frames with 3 modules)
MD812
Hood cover for 12 modules (3 frames with 4 modules)
MD91
Rain shelter for 1 module
MD92
Rain shelter for 2 modules
MD93
Rain shelter for 3 modules
MD94
Rain shelter for 4 modules (2 frames with 2 modules)
MD904
Rain shelter for 4 modules (1 frame with 4 modules)
MD96
Rain shelter for 6 modules (2 frames with 3 modules)
MD908
Rain shelter for 8 modules (2 frames with 4 modules)
MD99
Rain shelter for 9 modules (3 frames with 3 modules)
MD912
Rain shelter for 12 modules (3 frames with 4 modules)
MD100
Amplified door station with 1 push-button
MD122
Module for door speaker with 2 push-buttons, 2 row
MD124
Module for door speaker with 4 push-buttons, 2 row
MD200
Amplified door station with 2 push-buttons
MD222
Button module with 2 push-buttons, 2 row
MD224
Button module with 4 push-buttons, 2 row
MD226
Button module with 6 push-buttons, 2 row
MD228
Button module with 8 push-buttons, 2 row
PRS210
Transformer 13Vac - 15VA
PT510
Bicolour intercom Project series
PT510N
Beige intercom Project series
PT510W
White intercom Project series
PT520
Bicolour extendable intercom Project series
PT520N
Beige extendable intercom Project series
PT520W
White extendable intercom Project series
PT538
Desk adapter for intercom Project series
PT5100MD Videokit with PT5160 monitor
PT5100MDCW Colour videokit Project series
PT5100MDW Videokit with PT5160W monitor
PT5160
Bicolour Flat monitor Project series
PT5160MD Videokit with PT5160 and intercommunicating module
PT5160MDCW Colour videokit with intercommunicating module
Article
65
(9GB-2002)
English
ACI srl
Via Loretana, 134 - 60021 Camerano AN Italy.
Tel. (+39) 71959631 / 2. Fax. (+39) 7195150.