HIS Mechanical Heat Pump (Model: HE 165) has been designed to provide students with a practical
and quantitative demonstration of the vapour compression cycle, and is suitable for all course levels
(intermediate to undergraduate). Refrigerators and heat pumps both use the vapour compression
cycle, and although the applications of these machines differ, the components are essentially the same. The HE
165 is capable of demonstrating the heat pump application where a large freely available energy source, such as
the atmosphere, is to be upgraded for water heating. The unit will be of particular interest to those studying
Mechanical Engineering, Energy Conservation, Thermodynamics, Building Services, Chemical Engineering, Plant
and Process Engineering, and Refrigeration and Air Conditioning
DESCRIPTION
The unit is a bench top unit with all components and
instrumentations mounted on the sturdy panel. The heat
pump consists of a hermetic compressor, a water
cooled condenser, a thermostatically controlled
expansion valve and an air heated evaporator. The
arrangement of the components are in a manner similar
to that used for many domestic air-water heat pumps
where they are visible from the front of the unit.
During the operation, slightly superheated refrigerant
SOLTEQ
iv) Condenser:
Refrigerant to water. Plate Heat Exchanger..
v) Evaporator:
Air to refrigerant. Serpentine copper tube with
aluminium fins and with integral fan.
OPTIONAL ITEMS
EXPERIMENTAL CAPABILITIES
- EI
DIGITAL INSTRUMENTATIONS
vi) Instrumentations:
Indicators for the measurement of relevant
temperatures, flowrates, pressures, and motor
power input.
i)
ii)
iii)
iv)
v)
-DAS
SOLDAS DATA ACQUISITION SYSTEM
i)
ii)
iii)
iv)
SPECIFICATIONS
i) Rig:
Bench top unit. Epoxy coated steel bench,
Ii) Refrigerant:
R134a
iii) Compressor:
Fully hermetic single cylinder reciprocating type.
Displacement 8.85 cm3.rev-1.
- CAL
SOLCAL COMPUTER AIDED LEARNING
SOFTWARE
i)
ii)
iii)
iv)
Rev1.0 17/06/2011
SOLTEQ
Electrical
Water
:240 VAC/1-phase/50 Hz
:Laboratory tap water, 20 LPM @ 20 m
head, Drainage.
OVERALL DIMENSIONS
: 0.65 m
: 0.60 m
: 1.00 m
4.00
1400
3.00
1000
800
2.00
600
400
COPH
1200
1.00
Power Input
Heat Output
COPH
200
0
30.0
32.0
34.0
36.0
38.0
40.0
42.0
44.0
46.0
0.00
48.0
4.00
1200
1000
3.00
800
2.00
600
400
COPH
Height
Depth
Width
SOLTEQ
REQUIREMENTS
1.00
Power Input
Heat Delivered
COPH
200
0
35.0
37.0
39.0
41.0
43.0
45.0
47.0
49.0
51.0
53.0
0.00
55.0
Rev1.0 17/06/2011
SOLTEQ
AGENT:
MSC- Status
BUATAN MALAYSIA
Company