Termostat
Termostat
Termostat
Thermostats for
Industrial Applications
monitoring
analysing
TER
Switching range:
-20...+30C to 80...+130C
OO
OO
T1
OO
2/01-2016
Technical Details
Switching devices
Normal version
Switch housing
Aluminium die-cast GD Al Si 12
Aluminium die-cast GD Al Si 12
Switch capacity
(applies only for version with microswitch)
8 A at 250 VAC
5 A at 250 VAC inductive
8 A at 24 VDC
3 A at 250 VAC
2 A at 250 VAC inductive
3 A at 24 VDC
0,03 A at 250 VDC
min. 2 mA, 24 VDC
Installation position
Protection IP 65
(in vertical position)
IP54
(on request IP65 by ZF 351)
IP65
-version
II 2G Ex d e IIC T6 Gb
ATEX-approval
Electrical connection
Terminal connection
Cable entry
Pg 11
M16x1.5
Ambient temperature
-15...+70C
-20...+60C
Switch point
Switching difference
Not adjustable
Medium temperature
Max. 60C
Vibration strength
Up to 4 g no noteworth deviations
At higher vibrations, the switching difference reduces. Usage above 25 g is not
permitted.
Insulation values
www.kobold.com
2/01-2016
Type of protection
Sensor systems
Room sensor
Rod sensor
Frost-protection sensor
TER-TRM
TER-TAM
TER-TX + R10
TER-TX + R6
2/01-2016
Ex-Zone 1 or 2
www.kobold.com
Description
Connection diagram
Normal version
Microswitch, single pole changeover
213
Gilded contacts
with little transition resistance (e. g. for
low tension). Cannot be supplied with
adjustable switching differential
301
351
970
971
www.kobold.com
2/01-2016
In case that one of the above mentioned options are needed, please add the above suffix to the ordering code.
The grub screw located above the scale is to be slackened off approx. 2 turns before
making an adjustment and tightened up again after setting.
The switching temperature is set by the spindle.
The set switching temperature can be read off on the scale.
Slight variations between the set value and the switching point are inevitable due to
the tolerances and spreads in the characteristics of the sensors and springs, also to
friction in the moving parts of the switch.
The thermostats are as a rule set in such a way the desired value setting and the actual switching temperature coincide best in the middle range.
Any possible divergences are uniformly distributed to either side.
Turning to right:
Turning to left:
The switching difference is changed by turning the threaded rod inside the setting
spindle. The lower switching point is not changed by adjusting the difference, only
the upper switching point is shifted by the amount of the difference. One revolution
of the difference screw varies the switching difference by approximately of the total
differential range.
Bear in mind when making the adjustment:
2/01-2016
Switching difference
(small scew)
Switching temperature:
Switching difference:
Electrical connection
Mounting position
The thermostats can also be installed outdoor, if they are mounted in a vertical position. On temperatures below 0C take care that there can form no condensation at the
sensor and inside the housing.
www.kobold.com
Description
KOBOLD room thermostats are suitable for industrial plant,
for greenhouses, cowsheeds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and
relay stations. Room thermostats are supplied with TER-H 1
wall bracket.
Dimensions [mm]
112
60
DIN
EN 175301
4,8
8,2
45,5
37
48,5
46
Pg11
Mounting position:
Optional
Max. ambient
temperature:
Max. temperature
at the sensor:
70C
Contact:
Single-pole changeover
Protection:
Installation:
With TER-H 1 support bracket or with
2 screws ( 4 mm) bulk-head
mounting
Adjustment:
Scale value corresponds with the
lower switching point (with falling
temperature), the upper switching
point is higher by the switching
differential
Plug connection:
By means of obliquely angled plug to
DIN EN 175301 (3-pole + earth
contact), cable entry Pg 11, max.
cable diameter 10 mm. Cable outlet
possible in 4 directions (spaced 90
apart)
Switching
temperature:
Adjustable from outside with screw-
driver
70
49
Range of adjustment
TER-TRM 022
-20...+20C
1.0 K (fixed)
TER-TRM 40
0...+40C
1.0 K (fixed)
TER-TRM 150
+10...+50C
1.0 K (fixed)
TER-TRMV 40
0...+40C
3 - 10 K (adjustable)
TER-TRMV 150
+10...+50C
3 - 10 K (adjustable)
www.kobold.com
2/01-2016
Model
Description
The KOBOLD rod thermostats can be installed as immersion
thermostats in pipelines and containers and for monitoring
temperature in air ducts. The suitable immersion tube has
to be chosen according to the application. (Immersion tubes
see page 11).
Dimensions [mm]
112
DIN
EN 175301
4,8
8,2
45,5
37
Housing:
Aluminium die-cast GD Al Si 12 to
DIN1725,
Mounting position:
Max. ambient
temperature at the
switching device:
70C
Max. temperature at
the sensor:
See table
60
46
48,5
Pg11
49
Contact:
Single-pole changeover
Protection:
Adjustment:
Scale value corresponds with the
lower switching point (with falling
temperature), the upper switching
point is higher by the switching diffe
rential
Plug connection:
100
Switching
temperature:
Adjustable from outside with
screw-driver
Switching difference: Not adjustable for values see
summary of types
Immersion tubes:
2/01-2016
Model
Range of adjustment
Immersion depth
Max. permissible
temperature at sensor
TER-TX 023
-20...+30C
135 mm
1.5 K
110C
TER-TX 150
+10...+50C
135 mm
1.5 K
110C
TER-TX 490
+40...+90C
135 mm
2.5 K
125C
TER-TX 813
+80...+130C
135 mm
4.0 K
150C
TER-TXB 023
-20...+30C
220 mm
1.5 K
110C
TER-TXB 150
+10...+50C
220 mm
1.5 K
110C
TER-TXB 490
+40...+90C
220 mm
2.5 K
125C
www.kobold.com
102.6
72
46
75301
8.2
45
33.5
32.5
67
56
4.8
Description
The KOBOLD rod thermostats can be installed as immersion
thermostats in pipelines and containers and for monitoring
temperature in air ducts. The suitable immersion tube has
to be chosen according to the application. (Immersion tubes
600.1
see page 11).
Dimensions [mm]
Housing
102.6
72
46
11.1
76.5
76.5
45
DIN
43650
Mounting position:
Max. ambient
temperature at the
switching device:
-20C...+60C
Pg11
Temperature sensor
Contact:
Single-pole changeover
Protection:
Adjustment:
Scale value corresponds with the
lower switching point (with falling
temperature), the upper switching
point is higher by the switching diffe
rential
4,8
32.5
8,2
37
56
42.3
45,5
48,5
60
46
33.5
76.5
112
45
Switching
temperature:
Adjustable from outside with
screw-driver
49
600.1
100
22
20
3.5
Type of protection
26
56
36.5
6
G1/4
II 2G Ex
d e IIC T6 Gb
G1/2
132
Model
Range of adjustment
Immersion depth
Switching
difference (mean
value)
Max. permissible
temperature at sensor
TER-Ex-TX 490
+40...+90C
135 mm
2.5 K
125C
www.kobold.com
2/01-2016
33.5
Housing:
Aluminium die-cast GD Al Si 12 to
DIN1725,
Max. temperature at
the sensor:
See table
4.8
8.2
Description
The sensor cartridge at the end of the capillary tube is the
actual active (temperature-sensitive) part of the sensor.
Changes in temperature on the capillary tube have no effect
on the switching point. Pressuretight installation of the sensor
in pressure vessels of all kinds is possible with the aid of
immersion tubes. (Immersion tubes see page 11).
112
Mounting position:
Max. ambient
temperature at the
switching unit:
70C
Capillary tube:
Sensor cartridge:
Contact:
Single-pole changeover
Protection:
Installation:
Plug connection:
By means of obliquely angled plug to
DIN EN 175301 (see the other
thermostats)
4,8
37
8,2
48,5
45,5
DIN
EN 175301
Pg11
49
Aluminium die-cast GD Al Si 12 to
DIN 1725
Adjustment:
Scale value corresponds with the
lower switching point (with falling
temperature), the upper switching
point is higher by the switching
differential
Dimensions [mm]
60
46
Housing:
Switching
temperature: Adjustable by means of screwdriver
on setting spindle (accessible after
removing terminal box cover)
100
2/01-2016
Model
Range of adjustment
Switching difference
(mean value)
Max. permissible
temperature at sensor
TER-TAM 022
-20...+20C
1.5 K
110C
TER-TAM 150
+10...+50C
1.5 K
110C
TER-TAM 490
+40...+90C
2.0 K
125C
TER-TAM 813
+80...+130C
2.0 K
150C
www.kobold.com
102.6
72
46
75301
8.2
45
33.5
32.5
56
67
4.8
Description
The sensor cartridge at the end of the capillary tube is the
actual active (temperature-sensitive) part of the sensor.
Changes in temperature on the capillary tube have no effect
on the switching point. Pressuretight installation of the sensor
in pressure vessels of all kinds is possible with the aid of
immersion tubes. (Immersion tubes see page 11).
Dimensions [mm]
Housing
600.1
102.6
72
46
11.1
DIN
43650
Temperature sensor
37
8,2
45
33.5
112
60
46
Mounting position:
Max. ambient
temperature at the
switching unit:
-20C...+60C
Capillary tube:
Sensor cartridge:
Contact:
Single-pole changeover
Pg11
49
Adjustment:
Scale value corresponds with the
lower switching point (with falling
temperature), the upper switching
point is higher by the switching
differential
4,8
48,5
45,5
32.5
56
42.3
Aluminium die-cast GD Al Si 12 to
DIN 1725
Installation:
76.5
76.5
76.5
45
Switching
temperature: Adjustable by means of screwdriver
on setting spindle (accessible after
removing terminal box cover)
100
600.1
II 2G Ex d e IIC T6 Gb
II 1/2D Ex ta/tb 22
IIIC T80C Da/Db
3.5
20
56
Type of protection
26
6
G1/4
G1/2
Order Details: (Example: TER-Ex-TAM
150)
132
10
Model
Range of adjustment
Switching difference
(mean value)
Max. permissible
temperature at sensor
TER-Ex-TAM 150
+10...+50C
1.5 K
110C
www.kobold.com
2/01-2016
36.5
33.5
Housing:
4.8
8.2
Thermowells
Model
Thermowells G ,
internal 8 mm
10
1/2"G
NPT
10
1/2" NPT
TER-R 6
40
25
5,5
117,5
8
15
132
40
12
12
17
5,5
40
28
17
TER-R 1 / Ms
TER-R 2 / Ms
TER-R 10 / Ms
TER-R 20 / Ms
135
220
135
220
151
236
-
TER-TAM...
TER-TX...
TER-R 1 / Nst
TER-R 2 / Nst
TER-R 10 / Nst
TER-R 20 / Nst
135
220
135
220
151
236
151
236
TER-TAM...
TER-TX...
TER-R 7
28
Suitable for
L2
L1
23
16
Overall length
L2 [mm]
L2
L1
16
Immersion depth
L1 [mm]
8
10
TER-RN 1 / Ms
135
151
TER-TAM...
TER-RN 2 / Ms
220
236
TER-RN 10 / Ms
135
151
TER-TX...
TER-RN 20 / Ms
220
236
Stainless steel type (1.4571 + 1.4401), " NPT, max. permissible pressure: 63 bar
TER-RN 1 / Nst
135
151
TER-TAM...
TER-RN 2 / Nst
220
236
TER-RN 10 / Nst
135
151
TER-TX...
TER-RN 20 / Nst
220
236
Thermowells with fixing flange for air ducts
Material: steel, chromated
TER-R 6
Immersion depth 135 mm
TER-TX...
TER-R 7
Immersion depth 220 mm
TER-H 2
Wall bracket model TER-H 1
including fixing screws and plugs ( 6 mm).
Included as standard with model TRM thermostats.
Wall bracket model TER-H 2
for fixing the sensor cartridges of capillary tube thermostats.
Suitable for all TER-TAM... capillary tube thermostats.
Sealing, model TER-P 2
consisting of cover plate and screw for covering and adjusting screws.
Heat conducting compound model TER-WLP 1
to improve the transfer of heat, e. g. in the case of contact thermostats.
Approx. 0.5 cm3 in handy dispenser.
Capillary tube bushing model TER-R 4
with 3 mm capillary tube screw in thread G .
Suitable for all models TER-TAM.
2/01-2016
www.kobold.com
11