TABLE OF CONTENTS
Table of Contents
METER PROFILE BLOCK ................................................................................................................. 1
METER INFORMATION BLOCK .................................................................................................... 2
PROGRAMMING DATA BLOCK .................................................................................................... 3
PHASE REVERSAL / IMBALANCE BLOCK
...................................................................... 4
DAXI DATA BLOCK ........................................................................................................................... 5
HOUR BLOCK ..................................................................................................................................... 6
LIMIT DETECTION BLOCK
..................................................................................................... 7
RELAY STATUS BLOCK ................................................................................................................... 8
THD SUMMARY BLOCK .................................................................................................................. 9
THD DETAIL BLOCK ......................................................................................................................... 10
HARM VOLT A REGISTERS ............................................................................................... 10
HARM VOLT B REGISTERS ............................................................................................... 10
HARM VOLT C REGISTERS ............................................................................................... 10
HARM AMP A REGISTERS ................................................................................................ 10
HARM AMP B REGISTERS ................................................................................................ 10
HARM AMP C REGISTERS ................................................................................................ 11
RESET BLOCK ..................................................................................................................................... 12
COMMUNICATION PARAMETERS .............................................................................................. 13
APPENDIX A: PROGRAMMING DATA BLOCK MAP ............................................................. 14
CONFIGURATION INFORMATION ........................................................................................ 15
Interval ............................................................................................................................15
Address ...........................................................................................................................15
Baud Rate ......................................................................................................................15
Configuration ...............................................................................................................15
VOLTS Full Scale .........................................................................................................16
AMPS Full Scale ...........................................................................................................16
Decimal Placement & LILCO Configuration ...................................................17
LILCO Configuration .................................................................................................17
Set Above/Below Lim 1 ...........................................................................................17
Set Above/Below LIM 2 ...........................................................................................18
VOLTS AN Lim1-FREQ Lim2 ...................................................................................18
RLY LIM 1 .......................................................................................................................18
RLY LIM 2-RLY2 LIM2 ................................................................................................18
Delay ON RLY1-2 ........................................................................................................18
SAB THD LIM 1-2 ........................................................................................................18
RLY THD LIM 1-2 .........................................................................................................19
RLY2 THD LIM 1-2 ......................................................................................................19
THD VOLTS A LIM 1 - THD AMPS C LIM2 ..........................................................19
RLY1-2 IMB LIM 1 .......................................................................................................19
IMB LIM 1 .......................................................................................................................20
Relay 1 Mode: ..............................................................................................................20
RELAY 2 MODE ............................................................................................................20
Delay off RLY1-2 .........................................................................................................20
KYZ Map, KYZ Factor ................................................................................................21
CT/PT Ratios .................................................................................................................21
System Reset ...............................................................................................................21
TOCI
TABLE OF CONTENTS
TOCII
14
13
12
11
10
Bits
8
VOLTS
0000
AN
BN
CN
W
0001
0002
0003
A
1
AB
BC
VA
R
---
---
VA
VA
PF
FQ
---
40001
IMB
---
---
40002
VA
---
40003
POWER
N
PF
RE
V
----
----
----
----
KF AMPS
B
THD VOLTS
HOUR
THD AMPS
LIMITS
0004
CA
KF VOLTS
B
AMPS
VAR
B
584/984
7
HARM VOLTS
RELAYS
0005+
VAR
HARM AMPS
A
---
---
40004
---
---
----
---
---
40005
KYZ
1
--3 CH
CH
RESERVED FOR FUTURE USE
2
---
40006+
Registers
4
584/984
5
METER NAME
0008+
40009+
METER NAME
0010+
0018+
40017+
40025+
VERSION NUMBERS
0020+
MODBUS
ANALOG
DIGITAL
40033+
Registers 0008-0011:
20 Bytes ASCII, containing the meter name, left justified and padded with ASCII SPACEs
(0x20)
Registers 0025-0027:
2 Bytes each twos complement number, representing a version number with a single
implied decimal point.
Registers
0
584/984
5
0028+
|
40041+
|
010C+
40269+
Registers 0028-0113:
Until written to, the Programming Data Block contains information accurate to the current
operation of the meter. Changes written to the Programming Data Block do not go into
effect until a system reset is requested through communication.
See Appendix A: Programming Data Block for specific information.
Registers
584/984
PHASE REVERSAL
0114
40277
PHASE IMBALANCE
0115
40278
Register 0114:
A 2 Byte value of 0 x 0000 = a phase sequence of A-B-C. A 2-Byte non-zero value = a phase
sequence of C-B-A.
Register 0115:
2 Byte twos complement number, representing a percent voltage imbalance with a single
implied decimal place.
584/984
Registers
INST (D)
584/984
Registers 584/984
AVE (A)
VOLT AN
VOLT BN
VOLT CN
VOLT AB
VOLT BC
VOLT CA
AMP A
AMP B
AMP C
AMP N
WATT
VAR
VA
PF
FREQ
WATT A
WATT B
WATT C
VAR A
VAR B
VAR C
VA A
VA B
VA C
PF A
PF B
PF C
KF VOLT A DM Only
KF VOLT B DM Only
KF VOLT C DM Only
KF AMP A DM Only
KF AMP B DM Only
KF AMP C DM Only
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
0116
0117
0118
0119
011A
011B
011C
011D
011E
011F
0120
0121
0122
0123
0124
0125
0126
0127
0128
0129
012A
012B
012C
012D
012E
012F
0130
0131
0132
0133
0134
0135
0136
0137
0138
0139
013A
013B
40279
40280
40281
40282
40283
40284
40285
40286
40287
40288
40289
40290
40291
40292
40293
40294
40295
40296
40297
40298
40299
40300
40301
40302
40303
40304
40305
40306
40307
40308
40309
40310
40311
40312
40313
40314
40315
40316
013D
013E
013F
0140
0141
0142
0143
0144
0145
0146
0147
0148
0149
014A
014B
014C
014D
014E
014F
0150
0151
0152
0153
0154
0155
0156
0157
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
015E
015F
0160
0161
0162
RESERVED
013C
40317
0163
40318
40319
40320
40321
40322
40323
40324
40325
40326
40327
40328
40329
40330
40331
40332
40333
40334
40335
40336
40337
40338
40339
40340
40341
40342
40343
40344
Registers
MAX (X)
584/984
MIN (I)
40351
40352
40353
40354
40355
0164
0165
0166
0167
0168
0169
016A
016B
016C
016D
016E
016F
0170
0171
0172
0173
0174
0175
0176
0177
0178
0179
017A
017B
017C
017D
017E
017F
0180
0181
0182
0183
0184
0185
0186
0187
0188
0189
40357
40358
40359
40360
40361
40362
40363
40364
40365
40366
40367
40368
40369
40370
40371
40372
40373
40374
40375
40376
40377
40378
40379
40380
40381
40382
40383
40384
40385
40386
40387
40388
40389
40390
40391
40392
40393
40394
018B
018C
018D
018E
018F
0190
0191
0192
0193
0194
0195
0196
0197
0198
0199
019A
019B
019C
019D
019E
019F
01A0
01A1
01A2
01A3
01A4
01A5
01A6
01A7
01A8
01A9
01AA
01AB
01AC
01AD
01AE
01AF
01B0
40396
40397
40398
40399
40400
40401
40402
40403
40404
40405
40406
40407
40408
40409
40410
40411
40412
40413
40414
40415
40416
40417
40418
40419
40420
40421
40422
40423
40424
40425
40426
40427
40428
40429
40430
40431
40432
40433
40356
018A
40395
01B1
40434
Registers 0116-01B1:
2 Byte twos complement numbers. Decimal placement and scales for voltages, currents
and power readings are available from the Programming Data Block.
Power Factor reported in units of 0.001 PF, divide by 1000. Frequency reported in units of
0.01 Hz, divide by 100.
K-Factor reported in units of 0.01 KF, divide by 100.
HOUR BLOCK
Hour Block
Registers
Registers
0
584/984
5
WATT HOUR
01B2+
40435+
VAR HOUR
01BA+
40443+
VA HOUR
01C2+
40451+
Register 501B2-01C9:
16 Bytes each ASCII, representing a 16 Byte BCD count of the base Hour function, in units
of Wh, VARh or VAh.
14
13
12
11
10
584/
984
5
THD VOLTS
01CA
---
01CB
A
N
01CC
+
---BN
--- --VOLTS
C
A
N
B
---
---
B
C
C
A
---
---
RE
V
IM
B
PF
FQ
---
14
13
12
11
10
--A
N
---BN
--- --VOLTS
C
A
N
B
---
---
---
VAR
VA
C
A
40460
40461
+
584/
984
THD AMPS
C
AMPS
B
C
40459
POWER
THD VOLTS
01D0
+
15
01CF
AMPS
Registers
01CE
3
THD AMPS
40463
POWER
N
VAR
VA
PF
FQ
---
40464
40465
+
Register 501CA-01CF:
A bit value of 1 means that the limit is being exceeded for the associated quantity.
A bit value of 0 means that the limit is not being exceeded for the associated quantity.
Relay 1 Bits
15
14
01DA
---
----
01DB
A
N
01DC
+
BN
13
11
10
--- --VOLTS
C
A
N
B
---
---
STATUS
THD VOLTS
O
LK
A
B
C
N
AMPS
B
C
C
A
VAR
---
01DE
A
N
01DF
RE
V
IM
B
40475
PF
FQ
----
40476
THD AMPS
B
POWER
VA
13
12
11
10
----
--- --VOLTS
C
A
N
B
---
---
STATUS
THD VOLTS
O
LK
A
B
C
N
AMPS
BN
B
C
15
---
RE
V
IM
B
40479
PF
FQ
----
40480
THD AMPS
A
B
POWER
C
A
B
C
N
W
VAR
A
RESERVED FOR FUTURE USE
VA
40481+
Relay 3 Bits
Registers
A
N
40477+
584/984
14
01E0+
01E0+
Relay 2 Bits
15
01E3
Registers
01E2
584/984
12
14
---BN
13
12
--- --VOLTS
C
A
N
B
11
--B
C
584/984
10
---
STATUS
THD VOLTS
O
LK
A
B
C
N
AMPS
REV
IMB
40483
PF
FQ
----
40484
THD AMPS
A
C
A
B
C
N
W
VAR
A
RESERVED FOR FUTURE USE
B
POWER
VA
40485+
Registers 01DA-01E3:
Status: A bit value of 1 for ON means the relay is activated, 0 means not activated.
A bit of 1 for LK means the relay is locked, 0 means not locked.
Other: A bit value of 1 means the associated limit has activated the relay.
A bit value of 1 means the associated limit has not activated the relay.
584/984
Registers
584/984
Registers
INST (D)
584/984
MAX (X)
40503
40504
40505
40506
Registers
01FC
01FD
01FE
01FF
584/984
MIN (I)
40509
40510
40511
40512
THD VOLT A
THD VOLT B
THD VOLT C
THD AMP A
01EA
01EB
01EC
01ED
40491
40492
40493
40494
RESERVED
RESERVED
RESERVED
RESERVED
01F6
01F7
01F8
01F9
THD AMP B
01EE
40495
RESERVED
01FA
40507
0200
40513
THD AMP C
01EF
40496
RESERVED
01FB
40508
0201
40514
Registers 01EA-0201:
2 Byte each twos complement numbers, representing a percentage with a single decimal
point.
10
584/984
Registers
PERCENT
HARM 0
|
HARM 31
0202
|
0240
0242+
10.2
HARM 31
0282
|
02C0
02C2+
HARM 0
|
0302
|
HARM 31
0340
HARM 0
|
0382
|
HARM 31
03C0
0241
40578
40579+
40643
|
0283
|
40705
02C1
40644
|
40706
40707+
40771
|
0303
|
40833
0341
40772
|
40834
40835+
40899
|
0383
|
40961
03C1
40900
|
40962
40963+
0402
|
0440
0442+
10
40577
40516
|
03C2+
10.5
0203
|
0342+
10.4
40515
|
10.3
584/984
PHASE
41027
|
0403
|
41089
0441
41028
|
41090
41091+
10.6
0482
|
41155
|
0483
|
41156
|
HARM 31
04C0
41217
04C1
41218
04C2+
41219+
Register 0202-04C1:
Percent: 2 Bytes each twos complement number, representing a percentage with a single
implied decimal point.
Phase: 2 Bytes each twos complement number, representing a phase angle with a single
implied decimal point.
11
RESET BLOCK
11
Reset Block
Registers
Bits
15
14
1
3
A
0502
0503
0504
1
2
B
584/984
7
A
M
P
POWER
A
B
B
C
VA
C
A
---
---
---
---
VAR
V
A
PF
FQ
---
41283
---
----
----
---
41284
VAR
VA
---
41285
----
---
----
----
---
41286
PF
KF AMPS
THD VOLTS
0505
8
V-PP
VAR
KF VOLTS
B
W
B
1
0
11
RESET
HOUR
THD AMPS
C
0506+
41287+
Registers 0502-0505:
Reset: A bit of 1 for X or I will reset the MAX or MIN, respectively, of indicated features.
The bits from indicated features will be cleared as their feature is reset.
Hour: A bit value of 1 for W, VAR, or VA will reset the WATT, VAR, or VA Hour counter.
Other: A bit value will reset the MAX or MIN of the associated feature upon setting either
the X or I bit in the Reset Group.
12
12
COMMUNICATION PARAMETERS
Communication Parameters
Meters with the MODBUS communication option can communicate with either ASCII or
RTU framing.
ASCII framing - 7 data bits, even parity, 1 stop bit
RTU framing - 8 data bits, no parity, 1 stop bits
User selection of this parameter can be accomplished either through communication (see
Appendix A: Programming Data Block Map) or by the user through the keypad.
Keypad selection is accomplished through the Programming mode in the System
Configuration function,
Group 0, Function 3. Switch PACK 2 Position C controls which framing mode to use for
MODBUS communication.
Switch setting 0 signifies RTU framing, while switch settings 1 signifies ASCII framing.
For a detailed explanation of the Programming Mode, see the Programming Manual.
MODBUS communication is limited to 50 registers per query.
13
13
14
0
Interval
VOLTS Full Scale
Set Above/Below Lim1
AMPS A Lim1
AMPS B Lim1
AMPS C Lim1
VOLTS BC Lim1
AMPS N Lim1
VAR Lim1
PF Lim1
Registers
1
Address
AMPS Full Scale
Set Above/Below Lim2
AMPS A Lim2
AMPS B Lim2
AMPS C Lim2
VOLTS BC Lim2
AMPS N Lim2
VAR Lim2
PF Lim2
584/984
2
Baud Rate
Decimal Placement
VOLTS AN Lim1
VOLTS BN Lim1
VOLTS CN Lim1
VOLTS AB Lim1
VOLTS CA Lim1
WATT Lim1
VA Lim1
FREQ Lim1
3
Config
LILCO
VOLTS AN Lim2
VOLTS BN Lim2
VOLTS CN Lim2
VOLTS AB Lim2
VOLTS CA Lim2
WATT Lim2
VA Lim2
FREQ Lim2
RLY2 Lim1
RLY1 THD Lim1-2
THD AMPS A Lim1
THD AMPS B Lim1
THD AMPS C Lim1
RELAY 1 MODE
Delay off RLY1-2
RLY2 Lim2
RLY2 THD Lim1-2
THD AMPS A Lim2
THD AMPS B Lim2
THD AMPS C Lim2
RESERVED
FOR
FUTURE
USE
RLY1 Lim1
Delay on RLY1-2
THD VOLTS A Lim1
THD VOLTS B Lim1
THD VOLTS C Lim1
RLY1-2 IMB Lim1
RELAY 2 MODE
KYZ MAP
RLY1 Lim2
SAB THD Lim1-2
THD VOLTS A Lim2
THD VOLTS B Lim2
THD VOLTS C Lim2
IMB Lim1
KYZ FACTOR
RESERVED
FOR
FUTURE
USE
CT Ratio
PT Ratio
KYZ MAP
40041+
40045+
40049+
40053+
40057+
40061+
40065+
40069+
40073+
40077+
40081+
40085+
40089+
40093+
40097+
40101+
40105+
40109+
40113+
40117+
40121+
40125+
40129+
40133+
40137+
40141+
40145+
40149+
40153+
40157+
40161+
40165+
40169+
40173+
40177+
40181+
40185+
40189+
40193+
40197+
40201+
40205+
40209+
40213+
40217+
40221+
40225+
40229+
40233+
40237+
40241+
40245+
40249+
40253+
40257+
40261+
40265+
010C+
0110+
40269+
40273+
SYSTEM RESET
13.1
Configuration Information
13.1.1
Interval
Register 0028:
2 Byte twos complement number representing the Integration Interval in seconds.
13.1.2
Address
Register 0029:
2 Byte twos complement number, which is the Address of the meter for communication
purposes.
Under MODBUS communications, this address should be between 1 and 247, inclusive.
13.1.3
Baud Rate
Register 002A:
2 Byte twos complement number, which is the Baud Rate being used for communications.
Only baud rate
valid for the meter in question should be used (e.g., 1200, 9600). Improper settings could
disable communication.
13.1.4
Configuration
Register 002B:
Register
002B
Bits
15
14
13
12
11
KV
KA
MW
REV
LZ
KV:
10
RS
T
584/984
----
DLT
AVG
----
ASCII
MOD
RLY1
RLY2
COM
DC
40044
MW:
REV:
LZ:
A bit value of 1 means leading zeros are blanked on the meter display.
15
A bit value of 0 means leading zeros are displayed on the meter display.
RST:
A bit value of 1 means that Reset Protection is enabled. (Resetting max/min and
hour function readings from the keypad requires the entry of a password).
A bit value of 0 means that Reset Protection is disabled. (Resetting hour function readings
from the keypad requires the entry of a password).
DLT:
AVG:
ASCII MOD:
ASCII
MOD
PROTOCOL
DNP 3.0
Modbus ASCII
Modbus RTU
RLY1:
Please see the Programming Manual about PACK 3 of Function 0, Group 3 for an
explanation of the meaning of these bits.
RLY2:
Please see the Programming Manual about PACK 3 of Function 0, Group 3 for an
explanation of the meaning of these bits.
COM:
Please see the Programming Manual about PACK 3 of Function 0, Group 3 for an
explanation of the meaning of these bits.
DC:
Please see the Programming Manual about PACK 3 of Function 0, Group 3 for an
explanation of the meaning of these bits.
These features duplicate those available in the switch PACKS of Function 0, Group 3, in the
meters Programming Mode.
For further information, please see the other manuals for the meter.
* Should these features be changed, a replacement Bezel should be ordered to reflect the
new units.
13.1.5
Register 002C:
2 Byte twos complement number representing the Full Scale for voltage. For decimal
placement, see Decimal Placement below.
13.1.6
Register 002D:
2 Byte twos complement number representing the Full Scale for current. For decimal
placement, see Decimal Placement below.
16
13.1.7
Registers
Registers
584/984
0
002E+
VOLTS DP
1
AMPS DP
WATT DP
LILCO CONFIG
40047+
Registers 002E-002F:
Each of the DP bytes represents the implied number decimal places in the associated
values. Valid values are '0'-'4', withmeanings from 'no implied decimal place' to 'four
implied decimal places'. These values effect the meanings of INST,MAX, MIN, Hour
functions, Full Scales, Limits and other readings.
13.1.8
LILCO Configuration
Register
Bits
7
002F
584/984
3
VOLT
AMP
POWER
Round by 10
Current Scale
Power Scale
0
ENABLE
LILCO
40048
Register 002F:
These settings affect readings in the LILCO mapping.
Round by 10:
0=no rounding
Current Scale:
0=Normal Mapping
Power Scale:
LILCO Enable:
13.1.9
Register
Bits
15
14
13
12
11
10
VOLTS
0030
AN
BN
CN
AB
584/984
7
AMPS
BC
CA
PF
FQ
---
POWER
N
VAR
VA
40049
Register 0030:
A bit value of 0 means the limit is exceeded if the associated value is greater than its Limit
1 value.
A bit value of 1 means the limit is exceeded if the associated value is less than its Limit 1
value.
17
For functions with negative numbers, the comparisons use absolute valued values.
Register
Bits
15
14
13
AN
BN
CN
12
11
10
BC
CA
VOLTS
0070
AB
584/984
7
VAR
AMPS
C
PF
FQ
---
POWER
VA
40113
Register 0070:
A bit value of 1 means that Limit 1 of the associated value will trigger Relay 1.
A bit value of 0 means that Limit 1 of the associated value will not trigger Relay 1.
Register
Bytes
0074
584/984
Relay 1
Relay 2
40117
Register 0074:
1 Byte unsigned binary number each, representing the delay time from a relay being reset
before it could be set in seconds.
Valid numbers are 0 to 250.
Register
18
Bits
584/984
15
14
13
12
11
10
Lim1
A
THD AMPS
---
---
Lim2
THD VOLTS
0075
THD VOLTS
---
----
THD AMPS
40118
Register 0075:
A bit value of 0 = the limit is exceeded if the associated value is greater than its Limit 1 or 2.
A bit value of 1 = the limit is exceeded if the associated value is less than its Limit 1 or 2.
Register
Bits
15
14
13
12
11
10
584/984
RLY1 Lim1
THD VOLTS
0076
---
---
RLY1 Lim2
THD AMPS
THD VOLTS
----
----
THD AMPS
A
40119
Register 0076:
A bit value of 1 means that the indicated limit of the associated value will trigger a Relay.
A bit value of 0 means that the indicated limit of associated value will not trigger Relay 1.
Register
Bits
15
14
12
11
10
----
----
---
---
---
----
REV
RLY1
0084
RE
V
IMB
584/984
13
---
---
---
---
----
---
RLY2
IMB
40133
Register 0084:
REV: A bit value of 1 means that Limit 1 for Phase Reversal will trigger the indicated Relay.
A bit value of 0 means that Limit 1 for Phase Reversal will not trigger the indicated Relay.
Phase Reversal Limit 1 is enabled by the REV bit in Config.
19
IMB: A bit value of 1 means that Limit 1 for Phase Imbalance will trigger the indicated
Relay.
A bit value of 0 means that Limit 1 for Phase Imbalance will not trigger the indicated Relay.
Phase Imbalance Limit 1 is always enabled.
Registers
Registers
IMB/REV
CONTROL
0086+
584/984
1
SET/ RESET
CONTROL
LOGIC CONTROL
40135+
Registers 0086-0087:
IMB/REV/CONTROL: 1 Byte twos complement number, where a value of 0 means that
Relay 1 is set by Phase Reversal or Imbalance Limits being exceeded and reset by normal
Reversal and Imbalance conditions. Non-zero values mean that Relay 1 is reset by Phase
Reversal or Imbalance Limits being exceeded and set by normal Reversal and Imbalance
conditions.
LOGIC CONTROL: 1 Byte twos complement number, where a value 0 means that all
Limits triggering Relay 1 should be added to set or reset the Relay. Non-zero values means
that all Limits triggering Relay 1 should be ORed to set or reset the Relay.
SET RESET CONTROL: 2 one Byte twos complement numbers. Two non-zero values
indicate that Relay 1 is normally reset, and exceeded limit set the Relay. Two values of zero
indicate that Relay 1 is normally set and exceeded limits reset the Relay. Other
combinations are reserved for future use.
Registers
Bytes
0
008A
Relay 1
584/984
1
Relay 2
40139+
Register 008A:
20
1 Byte unsigned binary number each, representing the delay time from a relay being set
before it could be reset in seconds.
Valid numbers are from 0 to 250
Registers
Registers
0
KYZ MAP
008B+
Port 1
584/984
1
Port 2
KYZ FACTOR
Port3
Port1
Port2
Port3
40143+
Register 008B-008D:
KYZ MAP:1 Byte twos complement numbers, signifying whether which ports should be
enabled for KYZ outputs of which functions.
Valid numbers are:
0 KYZ disabled
2 VA Hour KYZ
KYZ FACTOR:1 Byte twos complement numbers, representing the KYZ change in level per
Watt for each port. Valid numbers are:
0 one unit of Full Scale
Registers
0108+
Registers
584/984
CT Ratio
PT Ratio
40265+
Registers 0108-0109:
2 bytes, MSB first values. Displayed in the RTU Block in user definable format.
21
Communication can request for a reset of the meter by writing the value -1 (0xFFFF) to
this register. Any changes made to the Programming Data Block through communication
will go into effect only after this reset is performed. Any other form of reset will result in the
loss of any modifications to the Programming Data since the last meter was reset.
Writing the value 0 (0x0000) to this register will reset the Programming Data Block,
permanently removing any changes made to these registers since the last communication
requested reset.
22
14
14.1
System Sanity
Registers
Registers
584/984
SYSTEM SANITY
0000
40001
Register 0000:
2-byte indication of proper operation of a meter. A value of 0x0000 indicates the meter
detects it is operating properly.
Any other value is an indication that the meter detects an internal fault.
14.2
Polling Values
Registers
584/984
Registers
POLLING
AMP A
AMP B
AMP C
VOLT AN
VOLT BN
VOLT CN
WATT
VAR
000
1
000
2
000
3
000
4
000
5
000
6
000
7
000
8
584/984
POLLING
40002
WATT A
0009
40010
40003
WATT B
000A
40011
40004
WATT C
000B
40012
40005
VAR A
000C
40013
40006
VAR B
000D
40014
40007
VAR C
000E
40015
40008
40009
Register 0001-000E:
All registers use the least significant 12 bits as signed magnitude numbers. All polling
values report their magnitude based on the secondary currents and voltage, not the
primaries. Scaling for these values should be interpreted as follows:
0x0000 (0) = negative Full Scale 0x07FF (2047) = 0 0x0FFF (4096) = positive Full Scale
Full Scale for Voltage is 150 V on the secondary.
23
Full Scale for Current and Power depends on the settings of the MODBUS RTU
Configuration bits in the Programming Block.
14.3
CT/PT Ratios
Registers
Registers
584/984
CT RATIO
000F
40016
PT RATIO
0010
40017
14.4
Neutral Current
Registers
Registers
584/984
NEUTRAL CURRENT
0011
40018
Register 0011:
This register is formatted the same as registers 0001 - 000E.
14.5
Hour Readings
Registers
584/984
High
+KWatt/hour
-KWatt/hour
+KVAR/hour
-KVAR/hour
0012
0014
0016
0018
40019
40021
40023
40025
Registers
584/984
Low
0013
0015
0017
0019
40020
40022
40024
40026
24
14.6
Frequency
Registers
Registers
584/984
FREQUENCY
001A
40027
Register 001A:
This register uses the least significant 12 bits as a signed magnitude number. Scaling for
this values should be interpreted as follows:
0x0000 (0) = 45 Hz or less 0x07FF (2047) = 60 Hz 0x0FFF (4096) = 75 Hz or greater
Register 001B - 0062
These registers are reserved for future use.
14.7
Energy Reset
Registers
Registers
584/984
ENERGY RESET
0063
40100
Register 0063:
When a value of 0x0001 is written to this register, the HOUR readings on the meter will be
reset.
25
15
WATT
VAR
PF
WATT A
WATT B
Registers
584/984
NEG MAX
050A
41291
050B
41292
050C
41293
050D
41294
050E
41295
Registers
584/984
NEG MIN
41303
41304
41305
41306
41307
0516
0517
0518
0519
051A
WATT C
050F
41296
051B
41308
VAR A
VAR B
VAR C
PF A
PF B
0510
0511
0512
0513
0514
41297
41298
41299
41300
41301
051C
051D
051E
051F
0520
41309
41310
41311
41312
41313
PF C
0515
41302
0521
41314
Registers 01EA-0201:
2 Byte twos complement numbers. Decimal placement and scales for appropriate
readings are available from the Programming Data Block.
15.2
26
VOLT AN
VOLT BN
VOLT CN
VOLT AB
VOLT BC
VOLT CA
AMP A
AMP B
AMP C
AMP N
WATT
VAR
VA
PF
FREQ
WATT A
WATT B
WATT C
VAR A
VAR B
VAR C
Registers 584/984
INST (D)
0522
41315
0524
41317
0526
41319
0528
41321
052A
41323
052C
41325
052E
41327
0530
41329
0532
41331
0534
41333
0536
41335
0538
41337
053A
41339
053C
41341
053E
41343
0540
41345
0542
41347
0544
41349
0546
41351
0548
41353
054A
41355
Registers 584/984
AVE (A)
057C
41405
057E
41407
0580
41409
0582
41411
0584
41413
0586
41415
0588
41417
058A
41419
058C
41421
058E
41423
0590
41425
0592
41427
0594
41429
0596
41431
0598
41433
059A
41435
059C
41437
059E
41439
05A0
41441
05A2
41443
05A4
41445
Registers 584/984
MAX (X)
05D6
41495
05D8
41497
05DA
41499
05DC
41501
05DE
41503
05E0
41505
05E2
41507
05E4
41509
05E6
41511
05E8
41513
05EA
41515
05EC
41517
05EE
41519
05F0
41521
05F2
41523
05F4
41525
05F6
41527
05F8
41529
05FA
41531
05FC
41533
05FE
41535
Registers 584/984
MIN (I)
0630
41585
0632
41587
0634
41589
0636
41591
0638
41593
063A
41595
063C
41597
063E
41599
0640
41601
0642
41603
0644
41605
0646
41607
0648
41609
064A
41611
064C
41613
064E
41615
0650
41617
0652
41619
0654
41621
0656
41623
0658
41625
VA A
054C
05A6
0600
065A
41357
41447
41537
41627
VA B
VA C
PF A
PF B
PF C
054E
0550
0552
0554
0556
41359
41361
41363
41365
41367
05A8
05AA
05AC
05AE
05B0
41449
41451
41453
41455
41457
0602
0604
0606
0608
060A
41539
41541
41543
41545
41547
065C
065E
0660
0662
0664
41629
41631
41633
41635
41637
060C
060E
0610
0612
0614
0616
0618
061A
061C
061E
0620
MAX (X)
41548
41551
41553
41555
41557
41559
41561
41563
41565
41567
41569
0666
0668
066A
066C
066E
0670
0672
0674
0676
0678
067A
MIN (I)
41639
41641
41643
41645
41647
41649
41651
41653
41655
41657
41659
THD VOLT A
THD VOLT B
THD VOLT C
THD AMP A
THD AMP B
THD AMP C
KF VOLT A DM Only
KF VOLT B DM Only
KF VOLT C DM Only
KF AMP A DM Only
KF AMP B DM Only
0558
055A
055C
055E
0560
0562
0564
0566
0568
056A
056C
INST (D)
41369
41371
41373
41375
41377
41379
41381
41383
41385
41387
41389
AVE (A)
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
KF AMP C DM Only
056E
41391
RESERVED
0622
41571
067C
41661
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
0570
0572
0574
0576
0578
41393
41395
41397
41399
41401
05CA
05CC
05CF
05D0
05D2
41483
41485
41487
41489
41491
0624
0626
0628
062A
062C
41573
41575
41577
41579
41581
067E
0680
0682
0684
0686
41663
41665
41667
41669
41671
RESERVED
057A
41403
05D4
41493
062E
41583
0688
41673
Registers 0522-0689:
Every 2 registers hold a 4 byte floating-point number. The format of a pair of registers is as
follows:
Registers
0522+
15
Sign
0
15.3
14
7
Exponent
REGISTER 0
7
6
0
22
15
584/984
REGISTER 1
Fraction
41315+
WATT
VAR
PF
WATT A
WATT B
Registers
584/984
NEG MAX
068A
41675
068C
41677
068E
41679
0690
41681
0692
41683
Registers
584/984
NEG MIN
06A2
41699
06A4
41701
06A6
41703
06A8
41705
06AA
41707
WATT C
0694
41685
06AC
41709
VAR A
VAR B
VAR C
PF A
0696
0698
069A
069C
41687
41689
41691
41693
06AE
06B0
06B2
06B4
41711
41713
41715
41717
27
PF B
069E
41695
06B6
41719
PF C
06A0
41697
06B8
41721
584/984
Registers
Registers 068A-06B9:
Every 2 registers hold a 4-byte floating-point number.
15.4
584/984
PHASE
HARM 0
|
06BA
|
41723
|
06BC
|
41725
|
HARM 31
0736
41847
0738
41849
HARM 0
|
073A
|
41851
|
073C
|
41853
|
HARM 31
07B6
41975
07B8
41977
07BA
|
41979
|
0303
|
41981
|
HARM 31
0836
42103
0838
41205
083A
|
42107
|
083C
|
42109
|
HARM 31
08B6
42231
08B8
42233
HARM 0
|
08BA
|
42235
|
08BC
|
42237
|
HARM 31
0936
42359
0938
42361
HARM 0
|
093A
|
42363
|
093C
|
42365
|
HARM 31
09B6
42487
09B8
42489
Register 0202-04C1:
Percent: 2 registers, a 4-byte floating point number representing a percentage with a
single implied decimal point.
28
Phase: 2 registers, a 4-byte floating point number representing a phase angle with a single
implied decimal point.
15.5
584/984
-WATT HOUR
09BA +
42491+
-VAR HOUR
09C2+
42499+
29
16
584/984
WATT HOUR
09CE+
42511+
VAR HOUR
09D6+
42519+
VA HOUR
09DE+
42527+
-WATT HOUR
09E6+
42535+
-VAR HOUR
09EE+
42543+
Registers 09CE-09F5:
16 Bytes each ASCII, representing a 15-Byte BCD count of the Base Hour Function, in units
of Wh, VARh and VAh.
The least significant byte of the last register in each Hour Reading is the ASCII null
character ( 0x 00 ).
16.2
Exception Flags
09F6
15
14
13
12
11
10
L1
L2
42551
Register 09F6:
L1:
L2:
30
R:
I:
W:
16.3
Input Status:
09f7
15
14
13
12
11
10
I1
I2
I3
I4
42552
Register 09F7:
A bit value of 1 means the associated input is active
A bit value of 0 means the associated input is not active.
16.4
Buffer Status
Programming Status
42553
42554
Register 09F8:
[Buffer Status]
2 Bytes
0x00000
0x0001-0x0FFFE
0x0FFFF
Register 09F9:
16.5
[Programming Status]
2 Bytes
0x00000
0x00001-0x0FFFF
10 bytes
31
09FA
09FB
15
7
THD VA
15
VAN
7
IC
14
6
THD VB
14
VBN
6
IN
13
5
THD VC
13
VCN
5
W
12
4
THD IA
12
VAB
4
VAR
11
3
THD IB
11
VBC
3
VA
10
2
THD IC
10
VCA
2
PF
9
1
REV
9
IA
1
FQ
8
0
IMB
8
IB
0
-
12
4
THD IA
12
VAB
4
VAR
11
3
THD IB
11
VBC
3
VA
10
2
THD IC
10
VCA
2
PF
9
1
REV
9
IA
1
FQ
8
0
IMB
8
IB
0
-
12
Input 4
4
-
11
3
-
10
2
-
9
1
-
8
0
-
42555
42556
Limit 2 - 4 bytes
09FC
09FD
15
7
THD VA
15
VAN
7
IC
14
6
THD VB
14
VBN
6
IN
Inputs
09FE
15
Input 1
7
-
13
5
THD VC
13
VCN
5
W
42557
42558
- 2 bytes
14
Input 2
6
-
13
Input 3
5
-
42559
Registers 09FF-0A02:
[Exceed]
8 bytes
09FF
0A00
15
7
THD VA
15
VAN
7
IC
14
6
THD VB
14
VBN
6
IN
13
5
THD VC
13
VCN
5
W
12
4
THD IA
12
VAB
4
VAR
11
3
THD IB
11
VBC
3
VA
10
2
THD IC
10
VCA
2
PF
9
1
REV
9
IA
1
FQ
8
0
IMB
8
IB
0
-
12
4
THD IA
12
VAB
4
VAR
11
3
THD IB
11
VBC
3
VA
10
2
THD IC
10
VCA
2
PF
9
1
REV
9
IA
1
FQ
8
0
IMB
8
IB
0
-
42560
42561
Limit 2 - 4 bytes
0A01
0A02
15
7
THD VA
15
VAN
7
IC
14
6
THD VB
14
VBN
6
IN
13
5
THD VC
13
VCN
5
W
42562
42563
Registers 0A03-0A2B:
[Values]
0A03+
0A0B+
0A13+
0A1B+
0A23+
32
0
VAN
IC
WB
PF A
KF IC
1
VBN
IN
WC
PF B
THD VA
82 bytes
2
VCN
W
VAR A
PF C
THD VB
3
VAB
VAR
VAR B
KF VA
THD VC
5
VCA
PF
VA A
KF VC
THD IB
6
IA
FQ
VA B
KF IA
THD IC
7
IB
WA
VA C
KF IB
Reversal
42564+
42572+
42580+
42588+
42596+
0A2B
Imbalance
42604
Register 0A2C:
[Inputs]
0A2C
15
Input 1
7
-
2 bytes
14
Input 2
6
-
13
Input 3
5
-
12
Input 4
4
-
11
3
-
10
2
-
9
1
-
8
0
-
42605
Registers 0A2D-0A2F:
[Time Stamp]
0A2D+
Day
6 bytes
Month
Year
Serial Seconds
42606+
Day
Month
= 1~12
Year
Serial Seconds
4 bytes
[DPs]
4 bytes
[FPs]
4 bytes
kAmps
MWatts
Reserved, 1 byte
[I/A]
readings
1 byte
0x000
0A30+
0A34+
0
FP Volts
FS Volts
FP Amps
FP watts
Reserved byte
2
Reserved
I/A
FS Amps
Reserved
42609+
24613+
Registers 0A37-0A50:
[Limit 1]
52 bytes
33
0A37+
0A3F+
0A47+
0A4F+
0
VAN
IC
-VAR
Reversal
1
VBN
IN
-PF
Imbalance
2
VCN
W
THD VA
3
VAB
VAR
THD VB
4
VBC
VA
THD VC
5
VCA
PF
THD IA
6
IA
FQ
THD IB
7
IB
-W
THD IC
42616+
42624+
42632+
42640+
Registers 0A51-0A6A:
[Limit 2]
0A51+
0A59+
0A61+
0A69+
0
VAN
IC
-VAR
Reversal
1
VBN
IN
-PF
Imbalance
52 bytes
2
VCN
W
THD VA
3
VAB
VAR
THD VB
4
VBC
VA
THD VC
5
VCA
PF
THD IA
6
IA
FQ
THD IB
7
IB
-W
THD IC
42642+
42650+
42658+
42666+
Register 0A6B:
Set Above/Below
A bit value of 0 means the limit is exceeded if the associated value is greater than its Limit.
A bit value of 0 means the limit is exceeded if the associated value is less than its Limit.
[SAB1]
0A6B
15
VAN
7
IC
14
VBN
6
IN
13
VCN
5
W
12
VAB
4
VAR
11
VBC
3
VA
10
VCA
2
PF
9
IA
1
FQ
8
IB
0
-
42668
11
VBC
3
VA
10
VCA
2
PF
9
IA
1
FQ
8
IB
0
-
42669
Register 0A6C:
[SAB2]
0A6C
15
VAN
7
IC
14
VBN
6
IN
13
VCN
5
W
12
VAB
4
VAR
Register 0A6D:
[SAB THD]
0A6D
34
15
THD VA
7
THD VA
14
THD VB
6
THD VB
2 bytes,
13
THD VC
5
THD VC
11
THD IB
3
THD IB
10
THD IC
2
THD IC
9
1
-
8
0
-
42670