Wire Phelps Dodge
Wire Phelps Dodge
Wire Phelps Dodge
APPLICATIONS
Type THHN/THWN-2 conductors
are primarily used in conduit for
services, feeder, and branch
circuits in commercial or industrial
applications as specified in the
Philippine Electrical Code (PEC) &
National Electrical Code (NEC).
When used as type THHN/THWN2, conductors are suitable for use
in wet or dry locations at
o
temperatures not to exceed 90 C
both dry and wet locations or not to
o
exceed 75 C exposed to oil or
coolant.
2
DESCRIPTION
Type THHN/THWN-2 is single
insulated conductor of solid or
stranded bare annealed high
conductivity
copper,
with
thermoplastic Lead free insulation
of PVC (Polyvinyl Chloride) and
protected by a nylon jacket;
designed to operate up to 600 volts
AC.
SPECIFICATIONS
The THHN/THWN-2 conductors
are designed according to local
and internationally recognized and
accepted standards:
ASTM: B3, B8
Underwriters
Laboratory:
Listed under file # E-55448 for
AWG Conductor sizes.
UL:83 Specification
PNS: 35 Specification
PEC
2000
Article
3.18
compliant for Cable tray
CHARACTERISTICS AND
SPECIAL FEATURES
Designed to operate at a
maximum
conductor
o
temperature of 90 C both for
wet and dry locations.
Higher cable ampacity.
Available in six standard
colors (red, black, white,
green, yellow and blue).
Copper
Equivalent Conductor
AWG size Diameter
PNS
Size
Overall
Approx
Cable Cable w eight
Diameter
mm
kgs/km
2.6
22
3.0
33
3.8
55
5.1
88
Standard
Packaging
Scheme
1.6 mm Sol
2.0 mm Sol
2.6 mm Sol
3.2 mm Sol
14 AWG
12 AWG
10 AWG
8 AWG
mm
1.6
2.0
2.6
3.2
14 AWG
12 AWG
10 AWG
8 AWG
1.8
2.3
2.9
3.6
2.8
3.3
4.1
5.5
24
37
58
96
25+
30+
40+
55
2.7
1.7
1.1
0.69
2.7
1.7
1.1
0.7
22
26
33
44
14 mm2 Str
22 mm2 Str
30 mm2 Str
6 AWG
4 AWG
2 AWG
4.6
5.7
6.7
6.5
8.1
9.0
147
232
311
70
90
115
0.44
0.29
0.19
0.45
0.3
0.2
52
64
72
38 mm2 Str
50 mm2 Str
60 mm2 Str
80 mm2 Str
100 mm2 Str
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
7.8
8.8
9.8
11.2
12.7
10.8
11.8
12.7
14.2
15.7
414
514
625
813
1,026
130
150
170
205
225
0.16
0.13
0.11
0.088
0.074
0.16
0.13
0.11
0.094
0.08
86
94
102
114
125
250 MCM
300 MCM
350 MCM
400 MCM
500 MCM
14.3
15.7
17.0
17.8
20.2
17.8
19.3
20.8
21.4
23.8
1,298
1,556
1,741
1,967
2,519
265
295
325
355
400
0.066
0.059
0.054
0.049
0.045
0.073
0.065
0.06
0.056
0.05
142
155
166
171
191
600 MCM
650 MCM
750 MCM
800 MCM
1000 MCM
22.3
22.9
25.0
25.5
28.2
26.9
26.9
29.6
29.7
32.2
2,964
3,218
3,677
3,974
4,809
447
470
500
515
580
0.042
0.04
0.037
0.036
0.032
0.048
0.047
0.044
0.043
0.04
215
215
237
237
258
+Unless otherwise specifically permitted the over current protection shall both exceed 15 amperes for
2
2
2
2.0mm (1.6mm); 20 Amperes for 3.5mm (2.0mm) and 25 Amperes for 5.5mm as per PEC.
o
++Ampacity Based on 90 C not more than three current carrying conductors in conduit based on ambient
o
temperature of 30 C as PEC 2000.
o
+++Effective Impedance for three conductors in conduit 60 HZ, 75 C and 600 Volts at P.F. Multiplying
current by effective impedance gives a good approximation for line to neutral voltage drop.
INSTALLATION
THHN/THWN-2 conductors can be installed
2
as follows: in conduit & raceways for 2.0mm
2
up to 500mm , or in cable trays for sizes
2
50mm up to 500mm2. It is important that the
installation instructions indicated by the
Philippine Electric Code, or National Electrical
Code, be followed to safeguard the safety of
people installing the product and eliminate
damage to the product due to improper
installation.
A subsidiary of: