Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Tellabs 6300 Managed Transport System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 78

Technical Documentation

Product family

Product name

Document

Tellabs 6300 Managed


Transport System
Tellabs 6325 Edge Node

Configuration and Ordering Guide


MA364 / Revision E3

Copyright 2005-2010 Tellabs. All rights reserved.

Tellabs 6325 Edge Node

Legal Notices

Legal Notices
Copyright Statement

This Tellabs manual is owned by Tellabs or its licensors and protected by U.S.
and international copyright laws, conventions, and treaties. Your right to use
this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws. Unauthorized reproduction, modification, distribution, display or other use of this manual may result in criminal and civil
penalties.

Trademark Notice

The following trademarks and service marks are owned by Tellabs Operations, Inc., or its affiliates in the United States and/or other countries: AUDIO
PLUS, CABLESPAN, CEC-128, DYNAMIC SIGNAL TRANSFER,
DXX, DXX logo, EC DUO, ENHANCED AUDIO PLUS, EXPRESS/PATH, FOCUS, MARTIS, MARTISDXX, MARTIS logo, MARTISDXX logo, METROVANTAGE, METROWATCH, NETREACH,
NETWISE, SCULPTURED SOUND, TELLABS, TELLABS and T symbol, T symbol, TELLABS PROPARTNER, TEL/MAP, TEL/MOR, THE
WORLD COMMUNICATES THROUGH TELLABS, TITAN, VERITY,
YOUR NETWORKING PARTNER.
Any other company or product names may be trademarks of their respective
companies.

MA364 Rev. E3

Tellabs 6325 Edge Node

Environmental Notices

Environmental Notices
Instructions for use,
maintenance and
management of residual
product

The equipment covered in this manual has been designed to fulfil the environmental demands of market and society. There are no apparent hazards during
use and on-site maintenance of the equipment. We recommend that repair of
defective equipment takes place at Tellabs premises, and it is likewise recommended to dispose of the equipment by use of certified local waste contractors
that can assure environmental safe handling and disposal of the equipment.
Arrangement for disposal of equipment can also be made through Tellabs.

Waste handling in
member states of the
European Union

The equipment covered in this manual must be disposed of in accordance


with "Directive 2002/96/EC of the European Parliament and of the council of
27 January 2003 on waste electrical and electronic equipment (WEEE)".
Disposal must follow national legislation for "IT and telecommunications
equipment" in accordance with the WEEE directive.
Do not dispose of waste electrical and electronic equipment with unsorted
municipal and household waste
Collect the equipment separately
Return the equipment through the collection system agreed with Tellabs.
Correct handling of the disposed equipment contributes to reuse, recycling
and other form of recovery to protect the environment.

Label

The equipment is marked with the figure shown below, to indicate that the
equipment must be collected separately. In case of very small products, the
figure may only be on the packaging or in this manual. The Tellabs name and
the production date will also be labelled on the product.

Further information

For further information about separation and handling the disposed equipment to ensure correct reuse or recycling, please look at www.tellabs.com.

MA364 Rev. E3

Tellabs 6325 Edge Node

Revision Information

Revision Information
Revision history

This guide has changed as follows:


Rev.

Date

Description of Changes

A1

Nov. 11, 2005

First version of the guide

A2

Feb. 28, 2006

Compared to revision A1:


120/75 ohm balun items for PIM1 module added. The balun provides 75 ohm E1 interface.
The name of the DC power supply module,
DC/DC converter, changed to PS-DC.
Ethernet cables added.
Minor changes have been performed.

B1

July 14, 2006

Compared to revision A2:


SPIMX module with 21 x 2 Mbit/s interfaces
added.
EMAP and ETEX10S modules added.
PS-DC module CM3561 (75 W) replaced by
CM3561-A (85 W).
Balun panel kit BNC added.
Minor changes have been performed.

B2

March 13, 2007

Compared to revision B1:


Tellabs 6325 node - Dedicated units added.
Pre-configured Tellabs 6325 node basic units
added.
Minor changes have been performed.

C1

Oct. 25, 2007

Compared to revision B2:


The following SDH/PDH modules added:
SPIMXm, SPIMX16m and PIM3P.
The following WDM modules added: OM-C,
OM-D, OAD1-C, OAD1-D, TR4 and MP4.
Various transceivers of type Ethernet, WDM,
bi-directional and Fibre Channel added.
Minor changes have been performed.

C2

Dec. 12, 2007

Compared to revision C1:


Cable WK-503Y-zz.z-11 replaced by WK-503Yzz.z-12.
Minor changes have been performed.

MA364 Rev. E3

Tellabs 6325 Edge Node

Rev.

D1

Date

May 14, 2008

Revision Information

Description of Changes

Compared to revision C2:


SIMX4 module replaced by SIMX4m module.
SIMX16 module replaced by SIMX16m module.
Transceiver TR-0028-xxx removed. In SDH
DWDM applications transceiver TR-0018-xxx
should be used.
Minor changes have been performed.

D2

Nov. 14, 2008

Compared to revision D1:


Balun WK-508B-01.0-01 removed.
Cable WK-504Y-zz.z-01 replaced by WK-504Yzz.z-10.
Cable WK-502X-03.0-01 replaced by WK-502Y03.0-01.
Transceivers TR-0024-xxx removed.
Minor changes have been performed.

D3

May 5, 2009

Compared to revision D2:


Item number for ETEX ESW CD-ROM added.
Minor changes have been performed.

E1

July 14, 2009

Compared to revision D3:


SPIMXm module replaced by SPIMXm-1 module.
SPIMX16m module replaced by SPIMX16m-1
module.
PIM1 module replaced by PIM1m module.
Optical Network Equipment protection of transponder and muxponder functions (Y-cable
protection) added.
STM-1 transponder mode in transponder and
muxponder modules added.
Minor changes have been performed.

E2

Nov. 27, 2009

Compared to revision E1:


Transceivers TR-0033-D/U added.
Minor changes have been performed.

E3

March 24, 2010

Compared to revision E2:


Transceivers TR-0032-xxx removed.
Minor changes have been performed.

MA364 Rev. E3

Tellabs 6325 Edge Node

Revision Information

MA364 Rev. E3

Tellabs 6325 Edge Node

Contents

Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1

Configuration Guide for Tellabs 6325 Node . . . . . . . . . . . . . . . . . . 11


1.1
1.2
1.3
1.4
1.5

1.6

1.7
1.8

1.9

Tellabs 6325 Node Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11


Configuring a Tellabs 6325 Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit . . . . . 14
Configuring a Tellabs 6325 Node by Selecting a Basic Unit . . . . . . . . 15
Configuring a Tellabs 6325 Node by Selecting Subrack and Modules 17
1.5.1
Selecting the Subrack and Support Modules for the Tellabs 6325
Node 18
1.5.2
Selecting the Traffic Modules for the Tellabs 6325 Node - SDH
Configurations 19
1.5.3
Selecting the Traffic Modules for the Tellabs 6325 Node - WDM
Stand-alone Configurations 28
1.5.4
Optical Network Equipment Protection . . . . . . . . . . . . . . . . . . 36
1.5.5
WDM Link Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Selecting the Transceivers for the Traffic Modules and Dedicated Units .
42
1.6.1
Selecting the Transceivers for the SDH Interfaces . . . . . . . . . 42
1.6.2
Selecting the Transceivers for the Ethernet Interfaces . . . . . . 46
1.6.3
Selecting the Transceivers for Bi-directional SDH/Ethernet Interfaces 49
1.6.4
Selecting the Transceivers for the Fibre Channel Interfaces . 50
Using Optical Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Selecting the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
1.8.1
Selecting the Traffic Interface Cables . . . . . . . . . . . . . . . . . . . 53
1.8.2
Selecting the Optical Network Equipment Protection Cables . 55
1.8.3
Selecting the Synchronization and Alarm Cable . . . . . . . . . . . 55
1.8.4
Selecting the Management Cables . . . . . . . . . . . . . . . . . . . . . 56
1.8.5
Selecting the Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . 56
1.8.6
Selecting the EOW Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Selecting the Embedded Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Ordering Information for Tellabs 6325 Node . . . . . . . . . . . . . . . . . 59


2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8

Dedicated Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Basic Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Subrack Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Balun Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Embedded Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MA364 Rev. E3

77

Tellabs 6325 Edge Node

Contents

MA364 Rev. E3

Tellabs 6325 Edge Node

Preface

Preface
Purpose

The purpose of this guide is to:


Describe how to configure the Tellabs 6325 node.
Provide a list of ordering numbers for the Tellabs 6325 node.

Prerequisite for using


this guide

This guide assumes that information from the network planning process is
available.

Product version

This guide describes Tellabs 6325 node, feature pack 1.4.

Structure of the
configuration and
ordering guide

The guide is structured as follows:


1 Configuration Guide for Tellabs 6325 Node on page 11 describes procedures to configure Tellabs 6325 node.
2 Ordering Information for Tellabs 6325 Node on page 59 provides a list
of ordering numbers for Tellabs 6325 node.

Tellabs 6325 node


configurator tool

This guide is meant as a supplement to the Tellabs 6325 node configurator tool
and vice versa.

Abbreviations used in
this guide

3R
ADM
CMCC
CT
CTE
CWDM
DC/DC
DWDM
E1
EMAP
EOW
ETEX
FE
FP
GbE
Km
Mbit/s
MP
MS-SPRing
NE
nm
NM
OAD
OM
PDH
PIM
ps
PS-DC
SDXC
SETS
SFP

MA364 Rev. E3

Transponder performing Re-amplification, Re-shaping and


Re-timing of the incoming signal
Add/Drop Multiplexer
Central Management and Communications Controller
Craft Terminal
Channel Terminating Equipment
Coarse Wavelength Division Multiplexing
DC/DC converter
Dense Wavelength Division Multiplexing
Electrical interface at 2 Mbit/s
Ethernet MAPper
Engineering Order Wire
Ethernet Tributary EXtension
Fast Ethernet
Feature Pack
Gigabit Ethernet
Kilometer
Megabit per second
Muxponder module
Multiplex Section Shared Protection Ring
Network Element
nanometer, (1*E-9 meter)
Network Management
Optical Add/Drop module
Optical Multiplexer/Demultiplexer module
Plesiochronous Digital Hierarchy
PDH Interface Module
picoseconds
Power Supply - DC (DC/DC converter)
Synchronous Digital Cross-Connect
Synchronous Equipment Timing Source
Small Formfactor Pluggable (Transceiver)

Tellabs 6325 Edge Node

SIMXm
SNC/I
SNC/N
SPIMX
SPIMXm
STM
STP
SW
TR
TRIB
VC-4
VC-12
WDM
XC
References to Tellabs
documents

10

Preface

SDH Interfaces, Cross-connection and SETS Module with


non-intrusive PDH monitoring
Inherently monitored Sub-Network Connection protection
Non-intrusively monitored Sub-Network Connection protection
SDH and PDH Interfaces and Cross-connection Module
SDH and PDH Interfaces, Cross-connection and SETS Module with non-intrusive PDH monitoring
Synchronous Transport Module
Shielded twisted pair
Software
Transponder module
Tributary
Virtual Container of 4'th order
Virtual Container of 1st order
Wavelength Division Multiplexing
Cross-connect (function)

[1] 63xx_an010-1, Tellabs 63xx Nodes, Using external Optical Amplifier at


STM-16, Application Note.

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Configuration Guide for Tellabs 6325 Node


This describes how you configure a Tellabs 6325 node.

Overview

1.1 Tellabs 6325 Node Items on page 11


1.2 Configuring a Tellabs 6325 Node on page 13
1.3 Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit on
page 14
1.4 Configuring a Tellabs 6325 Node by Selecting a Basic Unit on page 15
1.5 Configuring a Tellabs 6325 Node by Selecting Subrack and Modules
on page 17
1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 42
1.7 Using Optical Amplifiers on page 52
1.8 Selecting the Cables on page 52
1.9 Selecting the Embedded Software on page 56

1.1

Tellabs 6325 Node Items

Available items

These items are available for the Tellabs 6325 node.


Item

Dedicated Units

Description

Three non-modular variants that are complete nodes


for which only transceivers have to be added. The
three variants have the following interfaces:
Variant 1: 4 x STM-1/STM-4 (with SFP) and 63 x
2 Mbit/s 120 ohm
Variant 2: 4 x STM-1/STM-4 (with SFP) and 21 x
2 Mbit/s 120 ohm
Variant 3: 4 x STM-1/STM-4 (with SFP), 21 x
2 Mbit/s 120 ohm, 2 x FE (RJ-45) and 2 x FE (RJ-45
or with SFP)

MA364 Rev. E3

Basic Unit

Pre-configured Tellabs 6325 node comprising a subrack and a number of modules.

SC2

One rack unit (1RU) high subrack for the Tellabs


6325 node. Four slots for traffic modules. Various
modules can be installed in the subrack creating various configurations.

CMCC

Central management and communications controller


module

PS-DC

DC Power supply module (DC/DC converter)

AC/DC

External AC/DC adapter

11

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Item

FAN

Description

Cooling module with the following interfaces:


synchronization input and output
alarm

SIMX4m

SDH interface module, cross-connect and NE synchronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
4 x STM-1/STM-4 (with SFP)

SIMX16m

SDH interface module, cross-connect and NE synchronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)

SPIMX

SDH and PDH interface module, cross-connect and


NE synchronization (SETS) functions, with the following transport interfaces:
2 x STM-1/STM-4 (with SFP)
4 x 2 Mbit/s 120 ohm

SPIMXm-1

SDH and PDH interface module, cross-connect and


NE synchronization (SETS) functions, non-intrusive
PDH monitoring, with the following transport interfaces:
2 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm

SPIMX16m-1

SDH and PDH interface module, cross-connect and


NE synchronization (SETS) functions, non-intrusive
PDH monitoring, with the following transport interfaces:
1 x STM-1/STM-4/STM-16 (with SFP)
1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm

PIM1m

PDH interface module with the following transport


interfaces:
21 x 2 Mbit/s 120 ohm

PIM3P

PDH interface module with the following transport


interfaces:
6 x 34/45 Mbit/s 75 ohm

12

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Item

Description

ETEX10S

Ethernet switching and mapping module with


5 Gbit/s Ethernet switch. The module provides the
following transport interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)

EMAP

Ethernet mapping module with the following transport interfaces:


2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)

1.2

OM-C

8 channel CWDM multiplexer and demultiplexer


module.

OM-D

8 channel DWDM multiplexer and demultiplexer


module.

OAD1-C

1 channel CWDM optical add/drop multiplexer


module.

OAD1-D

1 channel DWDM optical add/drop multiplexer


module.

TR4

4 channel WDM transponder/repeater module.

MP4

4 channel WDM muxponder/transponder/repeater


module with NE synchronization (SETS) function.

Transceivers

Pluggable transceivers (SFP) are used to provide the


desired optical or electrical interfaces.

Baluns

120/75 ohm baluns provide 2 Mbit/s 75 ohm interfaces.

Configuring a Tellabs 6325 Node

To configure the Tellabs


6325 node

MA364 Rev. E3

There are three ways to configure the Tellabs 6325 node. They are as follows:
If

then

you require a fixed configuration


covered by one of the three dedicated units and do not need the possibility to expand or change your Tellabs 6325 node

Go to 1.3 Configuring a Tellabs 6325


Node by Selecting a Dedicated Unit
on page 14.

you require a configuration covered


by one of the pre-configured basic
units and the possibility to expand
or change your Tellabs 6325 node

Go to 1.4 Configuring a Tellabs 6325


Node by Selecting a Basic Unit on
page 15.

13

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

If

then

you want to configure the Tellabs


Go to 1.5 Configuring a Tellabs 6325
6325 node by selecting available sub- Node by Selecting Subrack and
rack and modules
Modules on page 17.

1.3

Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit

To configure a Tellabs
6325 node with a
dedicated unit

This procedure describes how to configure a Tellabs 6325 node with one of the
dedicated units of the Tellabs 6325 node.
Step

Action

Select the dedicated unit that fits your required application. The
units are listed in Item numbers of the dedicated units on page 14.

Select transceivers as described in 1.6 Selecting the Transceivers for


the Traffic Modules and Dedicated Units on page 42.

If required, select optical amplifier as described in 1.7 Using Optical


Amplifiers on page 52.

Select the cables as described in 1.8 Selecting the Cables on page 52.
Note: Two DC power cables are included when you order the dedi-

cated unit (CU...).


5

Item numbers of the


dedicated units

Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.

Select from the following units.


Description

Item number

Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-001


er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
63 x 2 Mbit/s 120 ohm
Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-002
er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm

14

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-003


er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)

1.4

Configuring a Tellabs 6325 Node by Selecting a Basic Unit

To configure a Tellabs
6325 node with a basic
unit

This procedure describes how to configure a Tellabs 6325 node by selecting


one of the pre-configured basic units.
Step

Action

Select the basic unit that fits your required application. The units are
listed in Item numbers of the basic units on page 16.

If you want to add traffic modules to the basic unit then go to Selecting additional modules on page 22.

Select transceivers as described in 1.6 Selecting the Transceivers for


the Traffic Modules and Dedicated Units on page 42.

If required, select optical amplifier as described in 1.7 Using Optical


Amplifiers on page 52.

Select the cables as described in 1.8 Selecting the Cables on page 52.
Note: Two DC power cables are included when you order the basic

unit (CU...).
6

MA364 Rev. E3

Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.

15

Tellabs 6325 Edge Node

Item numbers of the


basic units

1 Configuration Guide for Tellabs 6325 Node

Select from the following units.


Description

SDXC, pre-configured Tellabs 6325 node, basic


unit comprising the following items:

Item number

CU3560-001-A

1x SC2 subrack
1x SIMX4m module providing 4 x STM1/STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:

CU3560-003

1x SC2 subrack
1x SPIMX module providing 2 x STM-1/STM4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:

CU3560-005-C

1x SC2 subrack
1x SPIMXm-1 module providing 2 x STM1/STM-4 (with SFP) and 21 x 2 Mbit/s
120 Ohm, slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable

16

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

ADM16, pre-configured Tellabs 6325 node, basic


unit comprising the following items:

CU3560-006-A

1x SC2 subrack
2x SIMX16m module each providing 1 x STM16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:

CU3560-007

1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable

1.5

Configuring a Tellabs 6325 Node by Selecting Subrack and


Modules

To configure a Tellabs
6325 node

This procedure describes how to configure a Tellabs 6325 node.


Step

Action

Select the common items as described in 1.5.1 Selecting the Subrack


and Support Modules for the Tellabs 6325 Node on page 18. These
items are required in any configuration.

If you require an SDH configuration then select the traffic modules


as described in 1.5.2 Selecting the Traffic Modules for the Tellabs
6325 Node - SDH Configurations on page 19.
SDH configurations are Tellabs 6325 nodes with cross-connect functions, SDH/PDH/Ethernet interfaces etc.

If you require a WDM stand-alone configuration then select the traffic modules as described in 1.5.3 Selecting the Traffic Modules for
the Tellabs 6325 Node - WDM Stand-alone Configurations on page
28.
WDM stand-alone configurations are Tellabs 6325 nodes with only
WDM modules installed. These configurations are also referred to as
Tellabs 6325 Wavelength Division Multiplexing nodes.

MA364 Rev. E3

17

Tellabs 6325 Edge Node

1.5.1

1 Configuration Guide for Tellabs 6325 Node

Step

Action

Select transceivers as described in 1.6 Selecting the Transceivers for


the Traffic Modules and Dedicated Units on page 42.

If required, select optical amplifier as described in 1.7 Using Optical


Amplifiers on page 52.

Select the cables as described in 1.8 Selecting the Cables on page 52.

Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.

Selecting the Subrack and Support Modules for the Tellabs 6325 Node

Slots in the SC2 subrack

The SC2 subrack is a front access subrack comprising 9 slots for modules.

Selecting common items

In any configuration you need a subrack and support modules. Select the following items. See also information about item numbering in connection with
the change of manufacturing process. Refer to Lead Free Soldering on page
61.
Description

Item number

SC2 subrack, one rack unit (1RU) high, four slots UC3560
for traffic modules. The following items are delivered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Ejector tool
M4 x 8 screw and washer to attach ground
wire

18

FAN module

CM3565

CMCC, Central management and communications control module

CM3564

Power module(s)

See Selecting power


modules on page 19

MA364 Rev. E3

Tellabs 6325 Edge Node

Selecting power modules

1 Configuration Guide for Tellabs 6325 Node

Select the following power modules according to your requirement.


If

you want single DC supply

then

select the following items:


CM3561-A (PS-DC)
NS-0295 (Cover plate for slot 8)

you want redundant DC supply

select the following items:


2 x CM3561-A (PS-DC).

you want single AC supply

select the following items:


CM3561-A (PS-DC)
CM3569 (AC/DC adapter)
NS-0295 (Cover plate for slot 8)

you want redundant AC supply

select the following items:


2 x CM3561-A (PS-DC)
2 x CM3569 (AC/DC adapter)

you want one DC supply and one


AC supply

select the following items:


2 x CM3561-A (PS-DC)
1 x CM3569 (AC/DC adapter)

Common items

1.5.2

The figure shows the common items required in any configuration.

Selecting the Traffic Modules for the Tellabs 6325 Node - SDH
Configurations

To select the traffic


modules

MA364 Rev. E3

Follow this procedure to select the traffic modules for SDH configurations.

19

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
Step

Action

Select the module to perform the cross-connect and NE synchronization (SETS) functions. The module is located in slot 3 of the subrack.
Described in Selecting the module to perform the cross-connect and
NE synchronization (SETS) functions on page 20.

If your configuration requires protection of the cross-connect and NE


synchronization (SETS) functions then select the module to perform
the protection of the cross-connect and NE synchronization (SETS)
functions. The module is located in slot 2 of the subrack. Described in
Selecting the module to perform the protection of the cross-connect
and NE synchronization (SETS) functions on page 21.

Select additional traffic modules as described in Selecting additional


modules on page 22.
See also 1.5.4 Optical Network Equipment Protection on page 36.

Selecting the module to


perform the crossconnect and NE
synchronization (SETS)
functions

Find the item numbers of the traffic modules in Item numbers of


traffic modules on page 24.

Select the transceivers for the traffic modules as described in


1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 42.

The module that performs the cross-connect and NE synchronization (SETS)


functions is located in slot 3. Depending on which type of aggregate and tributary signals required in the network element different modules can be selected. Follow this procedure to select the module.
Note: The module in slot 3 (and 2) performs the non-intrusive monitoring

function of all E1/P12s in the network element. If you require the nonintrusive monitoring function, then you must select a SIMX4m,
SIMX16m, SPIMXm-1 or SPIMX16m-1 module for slot 3 (and 2). The
monitoring function is not supported in the SPIMX module with four
2 Mbit/s (CM3563).
If

and

your configuration requires the possibility


for MS-SPRing protection at STM-16 level

select the SIMX16m


module and add SFP
transceivers

you want an STM-16


interface

up to four STM-1/
STM-4 interfaces

select the SIMX16m


module and add SFP
transceivers

one STM-1/STM-4
interface

select the SPIMX16m-1


module and add SFP
transceivers. See also
Selecting external balun to provide 2 Mbit/s
75 ohm interface on
page 24.

up to 21 x 2 Mbit/s
interfaces

20

then

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

If

Selecting the module to


perform the protection of
the cross-connect and
NE synchronization
(SETS) functions

and

then

you want up to four


STM-1/STM-4 interfaces

select the SIMX4m


module and add SFP
transceivers

you want one or two


up to four 2 Mbit/s inSTM-1/STM-4 interfac- terfaces
es

select the SPIMX module and add SFP transceivers. See also Selecting external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.

up to 21 x 2 Mbit/s interfaces

select the SPIMXm-1


module and add SFP
transceivers. See also
Selecting external balun to provide 2 Mbit/s
75 ohm interface on
page 24.

The module that performs the protection of the cross-connect and NE synchronization (SETS) functions is located in slot 2. Depending on which type of
aggregate and tributary signals required in the network element different
modules can be selected. Follow this procedure to select the module.
Note: The module types in slot 2 and 3 do not necessarily have to be the same

as long as they both have the cross-connect and NE synchronization


(SETS) functions. You may, for instance, have a SPIMX16m-1 in slot 3
and a SIMX4m in slot 2.
If

and

your configuration requires the possibility


for MS-SPRing protection at STM-16 level

select the SIMX16m


module and add SFP
transceivers

you want an STM-16


interface

up to four STM-1/
STM-4 interfaces

select the SIMX16m


module and add SFP
transceivers

one STM-1/STM-4
interface

select the SPIMX16m-1


module and add SFP
transceivers. See also
Selecting external balun to provide 2 Mbit/s
75 ohm interface on
page 24.

up to 21 x 2 Mbit/s
interfaces

you want up to four


STM-1/STM-4 interfaces

MA364 Rev. E3

then

select the SIMX4m


module and add SFP
transceivers

21

Tellabs 6325 Edge Node

If

Selecting additional
modules

1 Configuration Guide for Tellabs 6325 Node

and

then

you want one or two


up to four 2 Mbit/s inSTM-1/STM-4 interfac- terfaces
es

select the SPIMX module and add SFP transceivers. See also Selecting external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.

up to 21 x 2 Mbit/s interfaces

select the SPIMXm-1


module and add SFP
transceivers. See also
Selecting external balun to provide 2 Mbit/s
75 ohm interface on
page 24.

In addition to the interfaces present on the module you have selected performing the cross-connect and NE synchronization (SETS) functions (slot 3) and, if
required, protection of the cross-connect and NE synchronization (SETS)
functions (slot 2), modules can be installed in slot (2), 4 and 5 to extend the
number of interfaces. When the module for slot 3 (and 2) has been selected,
then calculate the number of additional interfaces your configuration requires. Then select the type and number of modules that fits your configuration. The type of modules to provide additional interfaces are as follows:
Note: The cross-connect function in slot 3 (and 2) supports the STM-1/4 inter-

faces in slot 4 and 5 with a total capacity corresponding to 8 VC-4s (each


slot). Using the SIMX4m module in slot 4 or 5 limits the total capacity
of the four STM-1/4 interfaces to 8 VC-4s.
Module

SIMX16m

Interfaces

1 x STM-16 (with SFP)

Slot

4 x STM-1/STM-4 (with SFP)


SIMX4m

4 x STM-1/STM-4 (with SFP)

2, 4, 5

See the note about interface capacity in


slot 4 and 5.
SPIMX16m-1

1 x STM-1/STM-4/STM-16 (with
SFP)

1 x STM-1/STM-4 (with SFP)


21 x 2 Mbit/s 120 ohm
SPIMXm-1

2 x STM-1/STM-4 (with SFP)

2, 4, 5

21 x 2 Mbit/s 120 ohm


SPIMX

2 x STM-1/STM-4 (with SFP)

2, 4, 5

4 x 2 Mbit/s 120 ohm


PIM1m

22

21 x 2 Mbit/s 120 ohm

2, 4, 5

MA364 Rev. E3

Tellabs 6325 Edge Node

Module

PIM3P

1 Configuration Guide for Tellabs 6325 Node

Interfaces

6 x 34/45 Mbit/s 75 ohm

Slot

2, 4, 5

To enable equipment protection of the


mapping function the two PIM3P modules have to be installed in slot 4 and 5.
ETEX10S

4 x GbE (with SFP)

4+5

2 x FE (with SFP)
4 x FE (RJ-45)
EMAP

2 x FE (RJ-45)

2, 4, 5

2 x FE (RJ-45 or with SFP)


OM-C

2, 4, 5
8 channel CWDM multiplexer and demultiplexer module. The channel wavelengths are 1471, 1491, 1511, 1531, 1551,
1571, 1591 and 1611 nm

OM-D

8 channel DWDM multiplexer and demultiplexer module. The channel frequencies are 192.9, 193.0, 193.1, 193.2,
193.3, 193.4, 193.5 and 193.6 THz

2, 4, 5

OAD1-C

1 channel CWDM optical add/drop


multiplexer module. Select between the
following add/drop channel wavelengths: 1471, 1491, 1511, 1531, 1551,
1571, 1591 and 1611 nm

2, 4, 5

OAD1-D

1 channel DWDM optical add/drop


multiplexer module. Select between the
following add/drop channel frequencies: 192.9, 193.0, 193.1, 193.2, 193.3,
193.4, 193.5 and 193.6 THz

2, 4, 5

TR4

4 channel WDM transponder/repeater


module. A maximum of two TR4/MP4
modules can be installed in a subrack. If
the configuration requires two modules
then use one of the following slot combinations:

2, 4, 5

2 and 5
4 and 5
MP4

4 channel WDM muxponder/transpon- 2, 4, 5


der/repeater module. A maximum of
two TR4/MP4 modules can be installed
in a subrack. If the configuration requires two modules then use one of the
following slot combinations:
2 and 5
4 and 5

For systems with WDM modules see also WDM configurations on page 29.

MA364 Rev. E3

23

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

For 2 Mbit/s 75 ohm interfaces see Selecting external balun to provide 2


Mbit/s 75 ohm interface on page 24.
For equipment protection reasons you may consider the possibility to split the
SDH interfaces on separate modules.
Note: Remember to order cover plates for slots not used by modules.
Note: When you install SIMX and SPIMX modules it is recommended to start

with slot 2, then slot 4 and then slot 5. When you install PIM1m modules it is recommended to start with slot 5, then slot 4 and then slot 2.
However if your configuration requires an ETEX10S module the
PIM1m module can only be placed in slot 2.
Selecting external balun
to provide 2 Mbit/s
75 ohm interface

The 2 Mbit/s interfaces on the SPIMX and PIM1m modules are 120 ohm interfaces. If your configuration requires 75 ohm interfaces you must add the following items:
two external 120/75 ohm baluns per 2 Mbit/s interface. The balun has a
BNC connector and has to be installed in a balun panel. The balun item
number is WK-511B-KIT.
a balun panel kit BNC (item number NS-0299). Up to 42 baluns can be installed in the balun panel.
an open ended cable as used for the 120 ohm interface. See Electrical cables - 120 ohm on page 54.
The balun WK-511B-KIT provides only one connection. So you need two WK511B-KIT for a 2 Mbit/s interface, one for input and one for output connections.

Item numbers of traffic


modules

Select from the following traffic modules. See also information about item
numbering in connection with the change of manufacturing process. Refer to
Lead Free Soldering on page 61.
Description

Item number

SDH / PDH

SIMX16m, SDH interface module, cross-connect


and NE synchronization (SETS) functions, nonintrusive PDH monitoring, with the interfaces:

CM3568-A

1 x STM-16 (with SFP)


4 x STM-1/STM-4 (with SFP)
SIMX4m, SDH interface module, cross-connect
and NE synchronization (SETS) functions, nonintrusive PDH monitoring, with the interfaces:

CM3567-A

4 x STM-1/STM-4 (with SFP)

24

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

SPIMX16m-1, SDH and PDH interface module,


cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:

Item number

CM3575-A

1 x STM-1/STM-4/STM-16 (with SFP)


1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


SPIMXm-1, SDH and PDH interface module,
cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:

CM3574-B

2 x STM-1/STM-4 (with SFP)


21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


SPIMX, SDH and PDH interface module, crossconnect and NE synchronization (SETS) functions, with the interfaces:

CM3563

2 x STM-1/STM-4 (with SFP)


4 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


PIM3P, PDH interface module, with the interfaces:

CM3579

6 x 34/45 Mbit/s (E3/DS3) 75 Ohm


PIM1m, PDH interface module, with the interfac- CM3566-A
es:
21 x 2 Mbit/s (E1) 120 Ohm
Note: 75 ohm interfaces are available using an ex-

ternal balun.
Ethernet

ETEX10S, Ethernet switching and mapping mod- CM3572


ule, with the interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)

MA364 Rev. E3

25

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

EMAP, Ethernet mapping module, with the inter- CM3571


faces:
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
Optical multiplexer/demultiplexer

OM-C, 8 channel CWDM multiplexer and demul- CM3580C


tiplexer module
OM-D, 8 channel DWDM multiplexer and demultiplexer module

CM3580D

Optical add/drop multiplexer

26

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1471 nm

CM3581C-471

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1491 nm

CM3581C-491

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1511 nm

CM3581C-511

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1531 nm

CM3581C-531

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1551 nm

CM3581C-551

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1571 nm

CM3581C-571

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1591 nm

CM3581C-591

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1611 nm

CM3581C-611

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 192.90 THz

CM3581D-290

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.00 THz

CM3581D-300

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.10 THz

CM3581D-310

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.20 THz

CM3581D-320

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.30 THz

CM3581D-330

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.40 THz

CM3581D-340

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.50 THz

CM3581D-350

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.60 THz

Item number

CM3581D-360

Transponder/repeater/muxponder

TR4, 4 channel WDM transponder/repeater


module

CM3582

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
MP4, 4 channel WDM muxponder/transponder/repeater module

CM3585

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
Cover plate

Cover plate for empty slot 2-5 (position for traffic


module)
Example - ADM16 with 8
STM-1/STM-4 interfaces
and ETEX

NS-0292

The following example shows an ADM16 with 8 STM-1/STM-4 interfaces and


with an Ethernet switching and mapping module.

Items included in the example are:


Description

MA364 Rev. E3

Item number

SC2 subrack

UC3560

FAN

CM3565

CMCC

CM3564

2 x PS-DC

CM3561-A

27

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

2 x SIMX16m

CM3568-A

ETEX10S

CM3572

Interconnecting Tellabs
6325 nodes to extend
number of interfaces

It is possible to extend the configuration with another subrack if the number


of required interfaces exceed the capacity in one subrack. By interconnecting
two Tellabs 6325 nodes, through the cross-connect modules in slot 3, you double the number of available slots for traffic modules. In the management system the two nodes will be seen as two separate network elements.

Example - ADM4 with


126 x 2 Mbit/s interfaces

The following example shows an ADM4 with 126 x 2 Mbit/s interfaces. It is


realized by interconnecting two Tellabs 6325 nodes through STM-1 connections. This example shows two SIMX4m modules interconnected. This makes
it possible to have six PIM1m modules with a total of 126 x 2 Mbit/s interfaces.

1.5.3

Selecting the Traffic Modules for the Tellabs 6325 Node - WDM Standalone Configurations

To select the traffic


modules

Follow this procedure to select the traffic modules for WDM stand-alone configurations. These configurations are also referred to as Tellabs 6325 Wavelength Division Multiplexing nodes.
The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
Step
1

Action

Select the required WDM configuration as described in WDM configurations on page 29.
See also 1.5.4 Optical Network Equipment Protection on page 36
and 1.5.5 WDM Link Design on page 39.

28

Select the traffic modules as described in Selecting the WDM modules on page 33.
MA364 Rev. E3

Tellabs 6325 Edge Node

Step

WDM configurations

1 Configuration Guide for Tellabs 6325 Node

Action

Find the item numbers of the traffic modules in Item numbers of


traffic modules on page 35.

Select the transceivers for the traffic modules as described in


1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 42.

The following WDM configurations are possible with the Tellabs 6325 node.
If

then

select the OM-C module.


you require
an 8-channel
CWDM multiplexer and
demultiplexer

select the OM-D module.


you require
an 8-channel
DWDM multiplexer and
demultiplexer

MA364 Rev. E3

29

Tellabs 6325 Edge Node

If

1 Configuration Guide for Tellabs 6325 Node

then

you require a select the OM-C and OM-D modules.


15-channel
combined
CWDM and
DWDM multiplexer and
demultiplexer

you require a
1-channel
CWDM
add/drop
multiplexer

30

select the OAD1-C module.

MA364 Rev. E3

Tellabs 6325 Edge Node

If

MA364 Rev. E3

1 Configuration Guide for Tellabs 6325 Node

then

you require a
1-channel
DWDM
add/drop
multiplexer

select the OAD1-D module.

you require a
4-channel
transponder/
repeater

select the TR4 module and add SFP transceivers. See also
Using the MP4/TR4 module on page 33.

31

Tellabs 6325 Edge Node

32

1 Configuration Guide for Tellabs 6325 Node

If

then

you require a
4-channel
muxponder/
transponder/
repeater

select the MP4 module and add SFP transceivers. The MP4
module can operate in the following three configurations
controlled by the management software. See also Using
the MP4/TR4 module on page 33.

MA364 Rev. E3

Tellabs 6325 Edge Node

Using the MP4/TR4


module

1 Configuration Guide for Tellabs 6325 Node

The MP4 module can be used either as a Transponder/Repeater, similar to a


TR4 module, or as a Muxponder.

The Muxponder is able to multiplex/demultiplex signals on certain ports. A


description of the signals and ports is shown in the table below. The module
is capable of dual multiplexing/demultiplexing (4 signals to 2 signals). The
functionality (TR/MUX-1/MUX-2) of the MP4 module is set using the element manager software.
Possible signals

Port connections

TRP/REP (MP4 and TR4 modules)

STM-1, STM-4/OC-12, STM-16/OC- 1 2


48, 1000BASE-X, FC-100, FC-200,
34
FC-400
56
78
MUX-1 (MP4 module)

Client: 1000BASE-X, FC-100


Line: 1 x STM-16/OC-48

1 2, 3
56
78

MUX-2 (MP4 module)

Client: 1000BASE-X, FC-100


Line: 2 x STM-16/OC-48

Selecting the WDM


modules

MA364 Rev. E3

1 2, 3
5 4, 6
78

Select the type and number of modules that fits your configuration. The type
of modules are as follows:

33

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Note: If you require the NE synchronization (SETS) function in the subrack

then an MP4 module must be installed in slot 3.


Module

Interfaces

Slot

OM-C

8 channel CWDM multiplexer and demultiplexer module. The channel wavelengths


are 1471, 1491, 1511, 1531, 1551, 1571, 1591
and 1611 nm

2, 3, 4, 5

OM-D

8 channel DWDM multiplexer and demultiplexer module. The channel frequencies


are 192.9, 193.0, 193.1, 193.2, 193.3, 193.4,
193.5 and 193.6 THz

2, 3, 4, 5

OAD1-C

1 channel CWDM optical add/drop multiplexer module. Select between the following add/drop channel wavelengths: 1471,
1491, 1511, 1531, 1551, 1571, 1591 and 1611
nm

2, 3, 4, 5

OAD1-D

1 channel DWDM optical add/drop multi- 2, 3, 4, 5


plexer module. Select between the following add/drop channel frequencies: 192.9,
193.0, 193.1, 193.2, 193.3, 193.4, 193.5 and
193.6 THz

TR4

2, 3, 4, 5
4 channel WDM transponder/repeater
module. A maximum of two TR4/MP4
modules can be installed in a subrack. If
the configuration requires two modules
then use one of the following slot combinations:
2 and 3
2 and 5
3 and 4
4 and 5

MP4

4 channel WDM muxponder/transponder/repeater module with NE synchronization (SETS) function. A maximum of two
TR4/MP4 modules can be installed in a
subrack. If the configuration requires two
modules then use one of the following slot
combinations:

2, 3, 4, 5

2 and 3
2 and 5
3 and 4
4 and 5
Note: The MP4 module must be installed in

slot 3 to support the NE synchronization


(SETS) function.
Note: Remember to order cover plates for slots not used by modules.

34

MA364 Rev. E3

Tellabs 6325 Edge Node

Item numbers of traffic


modules

1 Configuration Guide for Tellabs 6325 Node

Select from the following traffic modules. See also information about item
numbering in connection with the change of manufacturing process. Refer to
Lead Free Soldering on page 61.
Description

Item number

Optical multiplexer/demultiplexer

OM-C, 8 channel CWDM multiplexer and demul- CM3580C


tiplexer module
OM-D, 8 channel DWDM multiplexer and demultiplexer module

CM3580D

Optical add/drop multiplexer

MA364 Rev. E3

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1471 nm

CM3581C-471

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1491 nm

CM3581C-491

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1511 nm

CM3581C-511

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1531 nm

CM3581C-531

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1551 nm

CM3581C-551

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1571 nm

CM3581C-571

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1591 nm

CM3581C-591

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1611 nm

CM3581C-611

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 192.90 THz

CM3581D-290

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.00 THz

CM3581D-300

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.10 THz

CM3581D-310

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.20 THz

CM3581D-320

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.30 THz

CM3581D-330

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.40 THz

CM3581D-340

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.50 THz

CM3581D-350

35

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.60 THz

Item number

CM3581D-360

Transponder/repeater/muxponder

TR4, 4 channel WDM transponder/repeater


module

CM3582

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
MP4, 4 channel WDM muxponder/transponCM3585
der/repeater module, NE synchronization (SETS)
function.
Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
Cover plate

Cover plate for empty slot 2-5 (position for traffic


module)

1.5.4
Introduction

NS-0292

Optical Network Equipment Protection


Optical network protection is a type of trail protection performed at the optical (OS/OCh) layer.
Optical network protection is a combination of optical line and equipment (Ycable) protection for muxponder/transponder (line) interfaces. The Y-cable
provides signal protection on the optical transmission system through paired
muxponder/transponder modules.

Description

The signal is split at the Y-cable and one copy of the signal is directed to a pre
defined facility on each module, resulting in a working signal and a protecting
signal. The two signals are then typically forwarded through the network via
different physical paths.
On the destination side, the signals are received by the muxponder/transponder modules, compared for integrity, and one is forwarded to the targeted client. However, in line-to-client port direction, the client port lasers on each
transponder are combined together. Only the client port side laser of the Active muxponder/transponder facility is turned on and transmits the signal to-

36

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

wards the receiving client equipment. The standby muxponder/transponder


facility must have its client port side laser turned off, because if both lasers
were active their signals would interfere severely at the point where the Y-cable joins.
The switching type is unidirectional.
The two MP4/TR4 (working and protecting) must be located in the same
node.
Example

The following picture shows an example of Optical Network Equipment protection for MP4 and TR4.

To select the required


items

Follow this procedure to select the required items for Optical Network Equipment protection:
Step

MA364 Rev. E3

Action

Select the MP4/TR4 modules required for your specific configuration including modules for protection.

Select the transceivers for the required interfaces.

37

Tellabs 6325 Edge Node

38

1 Configuration Guide for Tellabs 6325 Node

Step

Action

Select one Y-cable per client interface. See 1.8.2 Selecting the Optical
Network Equipment Protection Cables on page 55.

MA364 Rev. E3

Tellabs 6325 Edge Node

1.5.5

1 Configuration Guide for Tellabs 6325 Node

WDM Link Design

Introduction

When selecting the equipment for a WDM system it is recommended also to


have a power budget for the link. The following shows power budgets for different configurations.
Point to Point configuration on page 39
Optical Add/Drop configuration with OAD module on page 40
Optical Add/Drop back-to-back configuration with OM modules on
page 41

Point to Point
configuration

Make a power budget for a point-to-point link with either STM-16 CWDM or
STM-16 DWDM as shown in the following tables.

Power budget for a point-to-point link with STM-16 CWDM.


Parameter

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Insertion loss OM-C (Mux/Demux modules)

4.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

22.0

dB

Power budget for a point-to-point link with STM-16 DWDM


Parameter

MA364 Rev. E3

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Paired insertion loss OM-D (Mux/Demux


modules) (Maximum)

6.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

20.0

dB

39

Tellabs 6325 Edge Node

Optical Add/Drop
configuration with OAD
module

1 Configuration Guide for Tellabs 6325 Node

Make a power budget for an optical Add/Drop link (with OAD module) with
either STM-16 CWDM or STM-16 DWDM as shown in the following tables.

Power budget for an optical Add/Drop link (with OAD module) with STM16 CWDM.
Parameter

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Insertion loss OM-C (Mux/Demux modules)

4.0

dB

Insertion loss OAD1-C (Add/Drop module),


pass-through channels

2.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

20.0

dB

Power budget for an optical Add/Drop link (with OAD module) with STM16 DWDM
Parameter

40

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Paired insertion loss OM-D (Mux/Demux


modules) (Maximum)

6.0

dB

Insertion loss OAD1-D (Add/Drop module),


pass-through channels

3.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

17.0

dB

MA364 Rev. E3

Tellabs 6325 Edge Node

Optical Add/Drop backto-back configuration


with OM modules

1 Configuration Guide for Tellabs 6325 Node

Make a power budget for an optical Add/Drop back-to-back link with either
STM-16 CWDM or STM-16 DWDM as shown in the following tables.

Power budget for an optical Add/Drop back-to-back link with STM-16


CWDM.
Parameter

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Insertion loss OM-C (Mux/Demux modules)

4.0

dB

Insertion loss OM-C (Mux/Demux modules),


pass-through channels

4.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

18.0

dB

Power budget for an optical Add/Drop back-to-back link with STM-16


DWDM
Parameter

MA364 Rev. E3

Value

Unit

Tx launch power (Minimum)

0.0

dBm

Receive sensitivity

-28.0

dBm

Paired insertion loss OM-D (Mux/Demux


modules) (Maximum)

6.0

dB

Paired insertion loss OM-D (Mux/Demux


modules), pass-through channels

6.0

dB

Path penalty

2.0

dB

Span attenuation (connectors, ODF, splices


etc. and margin included)

14.0

dB

41

Tellabs 6325 Edge Node

1.6

1 Configuration Guide for Tellabs 6325 Node

Selecting the Transceivers for the Traffic Modules and


Dedicated Units
Select the transceivers for the traffic modules and dedicated units as described
in:

Overview

1.6.1 Selecting the Transceivers for the SDH Interfaces on page 42


1.6.2 Selecting the Transceivers for the Ethernet Interfaces on page 46
1.6.3 Selecting the Transceivers for Bi-directional SDH/Ethernet Interfaces on page 49
1.6.4 Selecting the Transceivers for the Fibre Channel Interfaces on page
50

1.6.1

Selecting the Transceivers for the SDH Interfaces

Selecting transceivers
for the SIMX and SPIMX
modules and the
Dedicated Units

The dispersion characteristics and attenuation for each specific interface is determined by an application code of the transceivers.
Note: If your configuration requires an optical amplifier, then go to 1.7 Using

Optical Amplifiers on page 52.


If the interface type is

electrical STM-1

then

select the electrical STM-1 SFP with 1.0/2.3 coaxial connectors.


Note: About size of electrical STM-1 SFPs: The

two connectors together, on the cables for the electrical STM-1 interface, are a little wider than the
transceiver. Due to this it will not be possible to install two electrical STM-1 transceivers in the cages
next to one another on the Dedicated Units. It
might (depending on the connector type) also be
difficult to replace a transceiver in neighbor position to an electrical STM-1 transceiver, without
disconnecting the electrical cables on the neighbor
position. This is the case only with the Dedicated
Units. On the SIMX4m, SIMX16m and SPIMX
modules the space between the cages makes it
possible to install electrical STM-1 transceivers in
all STM-1/4 cages.

42

optical STM-1

go to Selecting transceivers for optical STM-1 interface on page 43

STM-4

go to Selecting transceivers for STM-4 interface


on page 43

STM-16

go to Selecting transceivers for STM-16 interface


on page 43

MA364 Rev. E3

Tellabs 6325 Edge Node

Selecting transceivers
for optical STM-1
interface

The type of transceivers that you select for the optical STM-1 interface, is determined by the transmission wavelength and the attenuation of the fibre connection to the neighboring NE. The attenuation parameter is found by making
a power budget for the system.
if transmission wavelength is

Selecting transceivers
for STM-4 interface

then

attenuation is 0-12 dB

select the application


code S-1.1

1310 nm (long haul interface)

attenuation is 10-28 dB

select the application


code L-1.1

1550 nm (long haul interface)

attenuation is 10-28 dB

select the application


code L-1.2

1550 nm (very long


haul interface)

attenuation is 15-33 dB

select the application


code V-1.2

The type of transceivers that you select for the STM-4 interface, is determined
by the transmission wavelength and the attenuation characteristics of the fibre
connection to the neighboring NE. The attenuation parameters is found by
making a power budget for the system.
and If point S-R specification

then

1310 nm (short haul interface)

attenuation is 0-12 dB

select the application


code S-4.1

1310 nm (long haul interface)

attenuation is 10-24 dB

select the application


code L-4.1

1550 nm (long haul interface)

attenuation is 10-24 dB

select the application


code L-4.2

The type of transceivers that you select for STM-16 interface, is determined by
the transmission wavelength, attenuation and the dispersion characteristics of
the fibre connection to the neighboring NE. The attenuation and dispersion
parameters are found by making a power budget for the system.
if transmission wavelength is

MA364 Rev. E3

and If point S-R specification

1310 nm (short haul interface)

if transmission wavelength is

Selecting transceivers
for STM-16 interface

1 Configuration Guide for Tellabs 6325 Node

and If point S-R specification

then

1310 nm (short haul interface)

attenuation is 0-12 dB

select the application


code S-16.1

1310 nm (long haul interface)

attenuation is 10-24 dB

select the application


code L-16.1

1550 nm (long haul interface)

attenuation is 10-24 dB
and dispersion is <1600
ps/nm

select the application


code L-16.2

wavelength specific
(CWDM)

attenuation is 12-24 dB
and dispersion is <1600
ps/nm

select STM-16 CWDM

43

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

if transmission wavelength is

wavelength specific
(DWDM)

Item numbers of
transceivers

and If point S-R specification

attenuation is 10-26 dB
and dispersion is <2400
ps/nm

then

select STM-16 DWDM

Select from the following transceivers.


Description

Item number

SDH

SDH transceiver, SFP, 1.0/2.3 coaxial connectors,


75 ohm. For the applications:

TR-0021

STM-1 electrical
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0001

S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0002

L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0003

L-1.2
FE
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0019-551

V-1.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0004

S-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0005

L-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0006

L-4.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0007

S-16.1

44

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

SDH transceiver, SFP, LC connectors, single


mode fiber. For the applications:

Item number

TR-0008

L-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0009

L-16.2
Bi-directional SDH

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
SDH WDM

MA364 Rev. E3

45

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

SDH/Ethernet CWDM transceivers, multirate,


available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC connectors, single mode fiber. For the applications:

Item number

TR-0020-xxx

STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.

1.6.2

Selecting the Transceivers for the Ethernet Interfaces

Transceivers for
Ethernet interfaces

Select from the following transceivers.


Description

Item number

Fast Ethernet

Ethernet transceiver, SFP, RJ-45 connector,


shielded twisted pair. For the applications:

TR-0027

10/100BASE-T
Ethernet transceiver, SFP, LC connectors, multi
mode fiber. For the applications:

TR-0010

100BASE-FX
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0022

100BASE-LX10
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0001

S-1.1
FE

46

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

SDH/Ethernet transceiver, SFP, LC connectors,


single mode fiber. For the applications:

Item number

TR-0002

L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0003

L-1.2
FE
Gigabit Ethernet

Ethernet transceiver, SFP, RJ-45 connector,


shielded twisted pair. For the applications:

TR-0013

1000BASE-T
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012
nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0023

1000BASE-ZX
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:

TR-0029

1000BASE-SX
FC-100/200/400
Bi-directional Ethernet

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D

MA364 Rev. E3

47

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Ethernet WDM

SDH/Ethernet CWDM transceivers, multirate,


available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC connectors, single mode fiber. For the applications:

TR-0020-xxx

STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.

48

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Ethernet/Fibre Channel CWDM transceivers,


multirate, available wavelengths are 1471 nm 1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:

Item number

TR-0031-xxx

GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.

1.6.3

Selecting the Transceivers for Bi-directional SDH/Ethernet Interfaces

Selecting the bidirectional transceivers

If you want to send traffic in both directions using only one fiber then select
the bi-directional transceivers. Select a set of transceivers (-D/-U). The Dtransceiver transmitting at 1550nm (1490nm for TR-0033-D) is used in one end
of the fiber and the U-transceiver transmitting at 1310nm (1570nm for TR0033-U) is used at the other end of the fiber.
The attenuation range for the STM-1 transceivers is 0-13 dB and the attenuation range for the STM-4 transceivers is 0-10 dB.

Transceivers for STM-1 /


100BASE-BX bidirectional interfaces

Select the following transceivers.


Description

Item number

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U

MA364 Rev. E3

49

Tellabs 6325 Edge Node

Transceivers for STM-4 /


1000BASE-BX bidirectional interfaces

1 Configuration Guide for Tellabs 6325 Node

Select the following transceivers.


Description

Item number

TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
Transceivers for STM-16
/ 1000BASE-BX / FC100/200 bi-directional
interfaces

Select the following transceivers.


Description

SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.


For the applications:

Item number

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200

1.6.4

Selecting the Transceivers for the Fibre Channel Interfaces

Transceivers for Fibre


Channel interfaces

Select from the following transceivers.


Description

Item number

Fibre Channel

Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011


nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200

50

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Description

Item number

Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012


nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:

TR-0029

1000BASE-SX
FC-100/200/400
TR-0030
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the applications:
FC-100/200/400
Bi-directional Fibre Channel

SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.


For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Fibre Channel WDM

Ethernet/Fibre Channel CWDM transceivers,


multirate, available wavelengths are 1471 nm 1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:

TR-0031-xxx

GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.

MA364 Rev. E3

51

Tellabs 6325 Edge Node

1.7

1 Configuration Guide for Tellabs 6325 Node

Using Optical Amplifiers

Introduction

For a standard G.957 L-16.2 interface the distance between two nodes are limited to 80 km over a standard G.652 fiber. To reach longer distances, it is necessary to add a re-generator in the middle of the span, boost the output level
and/or improve the sensitivity of the receiver.
Using an external Optical Amplifier it is possible to increase the distance between two Tellabs 63xx nodes up to approx. 180 km depending on actual loss
and dispersion of the link.
Using optical amplifiers to increase the distance between Tellabs 63xx Nodes
is described in an application note [1].

1.8

Selecting the Cables

Type of cables available

The following type of cables are used for a Tellabs 6325 node.
Cables

Traffic interface cables

Used for

Connection of traffic interfaces. See


1.8.1 Selecting the Traffic Interface Cables on
page 53.

Optical Equipment pro- Connection of traffic interfaces in configurations


tection cables
with Optical Network Equipment protection. See
1.8.2 Selecting the Optical Network Equipment
Protection Cables on page 55.

52

Synchronization and
alarm cables

2 MHz input or output synchronization signals


and alarm signals. See 1.8.3 Selecting the Synchronization and Alarm Cable on page 55.

Management cables

Connection of network management, element


manager and craft terminal. See 1.8.4 Selecting
the Management Cables on page 56.

Power cables

Power connection to the PS-DC module. See


1.8.5 Selecting the Power Cables on page 56.

EOW cables

EOW connection to the EOW system. See


1.8.6 Selecting the EOW Cables on page 56.

MA364 Rev. E3

Tellabs 6325 Edge Node

1.8.1

1 Configuration Guide for Tellabs 6325 Node

Selecting the Traffic Interface Cables

Overview

Select the cables to be used for the modules/units.


Module/Unit

Dedicated Unit

SIMX

Interface

STM-4, optical STM-1


and optical Fast Ethernet

See Optical cables on


page 53

electrical STM-1

See Electrical cables 75 ohm on page 54

2 Mbit/s 120 ohm

See Electrical cables 120 ohm on page 54

electrical Fast Ethernet

Use standard Ethernet


cables. See Ethernet interface cables on page
56

STM-16, STM-4 and op- See Optical cables on


tical STM-1
page 53
electrical STM-1

SPIMX

MA364 Rev. E3

See Electrical cables 75 ohm on page 54

STM-16, STM-4 and op- See Optical cables on


tical STM-1
page 53
electrical STM-1

See Electrical cables 75 ohm on page 54

2 Mbit/s 120 ohm

See Electrical cables 120 ohm on page 54

PIM3P

34/45 Mbit/s

See Electrical cables 75 ohm on page 54

PIM1m

2 Mbit/s 120 ohm

See Electrical cables 120 ohm on page 54

ETEX10S, EMAP

optical

See Optical cables on


page 53

electrical

Use standard Ethernet


cables. See Ethernet interface cables on page
56

optical

See Optical cables on


page 53

OM-C, OM-D, OAD1C, OAD1-D, TR4, MP4


Optical cables

Cables

For optical interfaces, select between the following cables.

53

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Note: Optical transceivers use an LC connector for the optical interface.


Description

Item number

Optical single mode fiber cables, two fibers in one cable

2xLC to 2xLC single mode fiber cable, 0.3 m

W-OF203/00.3

2xLC to 2xLC single mode fiber cable, 5 m

W-OF203/05.0

2xLC to 2xLC single mode fiber cable, 10 m

W-OF203/10.0

2xLC to 2xLC single mode fiber cable, 20 m

W-OF203/20.0

2xLC to 2xFC/PC single mode fiber cable, 5 m

W-OF204/05.0

2xLC to 2xFC/PC single mode fiber cable, 10 m

W-OF204/10.0

2xLC to 2xFC/PC single mode fiber cable, 20 m

W-OF204/20.0

2xLC to 2xSC single mode fiber cable, 5 m

W-OF205/05.0

2xLC to 2xSC single mode fiber cable, 10 m

W-OF205/10.0

2xLC to 2xSC single mode fiber cable, 20 m

W-OF205/20.0

Optical multi mode fiber cables, two fibers in one cable

Electrical cables 120 ohm

2xLC to 2xLC multi mode fiber cable, 5 m

W-OF207/05.0

2xLC to 2xLC multi mode fiber cable, 10 m

W-OF207/10.0

2xLC to 2xLC multi mode fiber cable, 20 m

W-OF207/20.0

For SPIMX and PIM1m modules and Dedicated Units with 2 Mbit/s 120 ohm
interfaces, select between the following cables.
Description

Item number

Cables for SPIMX module with 4 x 2 Mbit/s

RJ-45 to open ended cable, 120 ohm, 5 m

WK-504Y-05.0-10

RJ-45 to open ended cable, 120 ohm, 10 m

WK-504Y-10.0-10

RJ-45 to open ended cable, 120 ohm, 20 m

WK-504Y-20.0-10

Cables for PIM1m, SPIMX modules with 21 x 2 Mbit/s and Dedicated Units

Electrical cables 75 ohm

54

MDR to open ended cable, 120 ohm, 5 m

WK-503Y-05.0-12

MDR to open ended cable, 120 ohm, 10 m

WK-503Y-10.0-12

MDR to open ended cable, 120 ohm, 20 m

WK-503Y-20.0-12

For electrical STM-1 interfaces and 34/45 Mbit/s 75 ohm interfaces select between the following cables.

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

Note: For easier removal of the coaxial cables, an extraction tool (item number

TOOL-H030) can be used.


Description

1.8.2

1.0/2.3 to 1.0/2.3 coaxial cable, 5 m

WK-482B-05.0-01

1.0/2.3 to 1.0/2.3 coaxial cable, 10 m

WK-482B-10.0-01

1.0/2.3 to 1.0/2.3 coaxial cable, 20 m

WK-482B-20.0-01

1.0/2.3 to BNC coaxial cable, 5 m

WK-483B-05.0-01

1.0/2.3 to BNC coaxial cable, 10 m

WK-483B-10.0-01

1.0/2.3 to BNC coaxial cable, 20 m

WK-483B-20.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 5 m

WK-484B-05.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 10 m

WK-484B-10.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 20 m

WK-484B-20.0-01

1.0/2.3 to open end coaxial cable, 20 m

WK-497B-20.0-01

Selecting the Optical Network Equipment Protection Cables

Equipment protection
cables

Select from the following equipment protection cables. You require one Y-cable per client interface. The cable connects TX signals and RX signals for both
working and protection signals. See the description in 1.5.4 Optical Network
Equipment Protection on page 36.
Description

1.8.3

Item number

Item number

Y-cable (optical splitter), 2xLC to 2x(2xLC) single


mode fiber cable, 5 m. The Y-cable splits client TX
and RX signals into working and protecting RX
and TX signals.

W-OF212/05.0

Y-cable (optical splitter), 2xLC to 2x(2xLC) multi


mode fiber cable, 5 m. The Y-cable splits client TX
and RX signals into working and protecting RX
and TX signals.

W-OF213/05.0

Selecting the Synchronization and Alarm Cable

Synchronization and
AUX alarm interface
cable

If you require a 2 MHz external synchronization input signal or synchronization output signal, then select the following cable. This cable also connect to
four AUX alarms.
Note: The plug type on the module is 9 pole D-Sub.
Description

9 pole D-sub to open ended, 120 ohm, 3 m

MA364 Rev. E3

Item number

WK-502Y-03.0-01

55

Tellabs 6325 Edge Node

1.8.4

1 Configuration Guide for Tellabs 6325 Node

Selecting the Management Cables

Ethernet interface cables

Use standard STP Ethernet interface cables (RJ-45).

Craft terminal interface


cable

If your network element requires connection to a craft terminal, then select the
following cable. You require one cable per craft terminal.
Description

Craft terminal interface cable, RJ-45 to 9 pole Dsub, 3 m

1.8.5

Item number

WK-480X-03.0-01

Selecting the Power Cables


Select the following power cable. You require one power cable per PS-DC
module. In case you want to use protected power you need two PS-DC modules and thereby also two power cables.

Power cable

Description

3 pole Molex mini-fit to open ended, 2.6 m

Item number

WK-500Z-02.6-01

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.

1.8.6

Selecting the EOW Cables

EOW cables

If your system includes an EOW system, then select the following cable.
Note: On the SPIMX modules with 21 x 2 Mbit/s the EOW system is connect-

ed with the 2 Mbit/s interface cable (WK-503Y-zz.z-12 - ref. Electrical


cables - 120 ohm on page 54). The open ended cable holds both the connections for the 2 Mbit/s interfaces and the EOW interface.
Description

RJ-45 to 15 pole D-sub, 3 m

1.9

WK-501Y-03.0-01

Selecting the Embedded Software

Embedded software

56

Item number

The Tellabs 6325 node (CMCC module) is delivered with an embedded software release pre-installed. The pre-installed ESW may be different from the
release you require for your configuration. Therefore it is recommended to order the CD-ROM with the ESW separately. ETEX modules are delivered with

MA364 Rev. E3

Tellabs 6325 Edge Node

1 Configuration Guide for Tellabs 6325 Node

an ETEX ESW release pre-installed. The pre-installed ETEX ESW may be different from the release you require for your configuration. Therefore it is recommended to order the CD-ROM with the ETEX ESW separately.
Description

MA364 Rev. E3

Item number

6325 ESW, FP1.4, CD-ROM

SW6325-0014M200

ETEX ESW, CD-ROM

SW-ETEX-M200

57

Tellabs 6325 Edge Node

58

1 Configuration Guide for Tellabs 6325 Node

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Ordering Information for Tellabs 6325 Node


This gives the item numbers available for Tellabs 6325 node.

Overview

2.1 Dedicated Units on page 59


2.2 Basic Units on page 60
2.3 Modules on page 61
2.4 Transceivers on page 65
2.5 Subrack Items on page 73
2.6 Balun Items on page 73
2.7 Cables on page 74
2.8 Embedded Software on page 76

2.1

Dedicated Units

Dedicated units

The following Tellabs 6325 node - dedicated units are available.


Description

Item number

Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-001


er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
63 x 2 Mbit/s 120 ohm
Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-002
er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
Tellabs 6325 node - Dedicated Unit, two DC pow- CU3561-003
er cables included. The unit provides the following interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)

MA364 Rev. E3

59

Tellabs 6325 Edge Node

2.2

2 Ordering Information for Tellabs 6325 Node

Basic Units

Basic units

The following pre-configured Tellabs 6325 node basic units are available.
Description

SDXC, pre-configured Tellabs 6325 node, basic


unit comprising the following items:

Item number

CU3560-001-A

1x SC2 subrack
1x SIMX4m module providing 4 x STM1/STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:

CU3560-003

1x SC2 subrack
1x SPIMX module providing 2 x STM-1/STM4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:

CU3560-005-C

1x SC2 subrack
1x SPIMXm-1 module providing 2 x STM1/STM-4 (with SFP) and 21 x 2 Mbit/s 120
Ohm, slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable

60

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

ADM16, pre-configured Tellabs 6325 node, basic


unit comprising the following items:

Item number

CU3560-006-A

1x SC2 subrack
2x SIMX16m module each providing 1 x STM16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:

CU3560-007

1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable

2.3

Modules

Lead Free Soldering

The manufacturing process of hardware modules is about to change from


leaded soldering to lead free soldering. To distinguish between modules manufactured with the two different processes '-R6' is added to the item number
for modules manufactured with a lead free process. The original generic ordering code, e.g. 'CM3563', is unchanged. However, the delivered module will
be labelled 'CM3563-R6' when this module is changed to lead free. Design and
functionality are unchanged.

SDH and PDH modules

The following SDH and PDH modules are available for the Tellabs 6325 node.
Description

SIMX16m, SDH interface module, cross-connect


and NE synchronization (SETS) functions, nonintrusive PDH monitoring, with the interfaces:

Item number

CM3568-A

1 x STM-16 (with SFP)


4 x STM-1/STM-4 (with SFP)

MA364 Rev. E3

61

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

SIMX4m, SDH interface module, cross-connect


and NE synchronization (SETS) functions, nonintrusive PDH monitoring, with the interfaces:

Item number

CM3567-A

4 x STM-1/STM-4 (with SFP)


SPIMX16m-1, SDH and PDH interface module,
cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:

CM3575-A

1 x STM-1/STM-4/STM-16 (with SFP)


1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


SPIMXm-1, SDH and PDH interface module,
cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:

CM3574-B

2 x STM-1/STM-4 (with SFP)


21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


SPIMX, SDH and PDH interface module, crossconnect and NE synchronization (SETS) functions, with the interfaces:

CM3563

2 x STM-1/STM-4 (with SFP)


4 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-

ing external baluns.


PIM3P, PDH interface module, with the interfaces:

CM3579

6 x 34/45 Mbit/s (E3/DS3) 75 Ohm


PIM1m, PDH interface module, with the interfac- CM3566-A
es:
21 x 2 Mbit/s (E1) 120 Ohm
Note: 75 ohm interfaces are available using an ex-

ternal balun.
Cover plate for empty slot 2-5 (position for traffic
module)

62

NS-0292

MA364 Rev. E3

Tellabs 6325 Edge Node

Ethernet modules

2 Ordering Information for Tellabs 6325 Node

The following Ethernet modules are available for the Tellabs 6325 node.
Description

Item number

ETEX10S, Ethernet switching and mapping mod- CM3572


ule, with the interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)
EMAP, Ethernet mapping module, with the inter- CM3571
faces:
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
Cover plate for empty slot 2-5 (position for traffic
module)
WDM modules

NS-0292

The following WDM modules are available for the Tellabs 6325 node.
Description

Item number

Optical multiplexer/demultiplexer

OM-C, 8 channel CWDM multiplexer and demul- CM3580C


tiplexer module
OM-D, 8 channel DWDM multiplexer and demultiplexer module

CM3580D

Optical add/drop multiplexer

MA364 Rev. E3

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1471 nm

CM3581C-471

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1491 nm

CM3581C-491

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1511 nm

CM3581C-511

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1531 nm

CM3581C-531

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1551 nm

CM3581C-551

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1571 nm

CM3581C-571

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1591 nm

CM3581C-591

OAD1-C, 1 channel CWDM optical add/drop


multiplexer module, 1611 nm

CM3581C-611

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 192.90 THz

CM3581D-290

63

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Item number

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.00 THz

CM3581D-300

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.10 THz

CM3581D-310

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.20 THz

CM3581D-320

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.30 THz

CM3581D-330

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.40 THz

CM3581D-340

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.50 THz

CM3581D-350

OAD1-D, 1 channel DWDM optical add/drop


multiplexer module, 193.60 THz

CM3581D-360

Transponder/repeater/muxponder

TR4, 4 channel WDM transponder/repeater


module

CM3582

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
MP4, 4 channel WDM muxponder/transponCM3585
der/repeater module, NE synchronization (SETS)
function.
Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
Cover plate

Cover plate for empty slot 2-5 (position for traffic


module)

64

NS-0292

MA364 Rev. E3

Tellabs 6325 Edge Node

Support modules

2 Ordering Information for Tellabs 6325 Node

The following support modules are available for the Tellabs 6325 node.
Description

2.4

Item number

PS-DC module

CM3561-A

AC/DC adapter

CM3569

CMCC, Central management and communications control module

CM3564

FAN module

CM3565

Cover plate for empty slot 8 (position for PS-DC


module)

NS-0295

Transceivers

Transceivers for SDH


interfaces

The following transceivers are available for the SDH interfaces of the Tellabs
6325 node.
Description

Item number

SDH

SDH transceiver, SFP, 1.0/2.3 coaxial connectors,


75 ohm. For the applications:

TR-0021

STM-1 electrical
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0001

S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0002

L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0003

L-1.2
FE
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0019-551

V-1.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0004

S-4.1

MA364 Rev. E3

65

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

SDH transceiver, SFP, LC connectors, single


mode fiber. For the applications:

Item number

TR-0005

L-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0006

L-4.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0007

S-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0008

L-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0009

L-16.2
Bi-directional SDH

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U

66

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.


For the applications:

Item number

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
SDH WDM

SDH/Ethernet CWDM transceivers, multirate,


available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC connectors, single mode fiber. For the applications:

TR-0020-xxx

STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
Transceivers for
Ethernet interfaces

The following transceivers are available for the Ethernet interfaces of the Tellabs 6325 node.
Description

Item number

Fast Ethernet

Ethernet transceiver, SFP, RJ-45 connector,


shielded twisted pair. For the applications:

TR-0027

10/100BASE-T

MA364 Rev. E3

67

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Ethernet transceiver, SFP, LC connectors, multi


mode fiber. For the applications:

Item number

TR-0010

100BASE-FX
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0022

100BASE-LX10
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0001

S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0002

L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:

TR-0003

L-1.2
FE
Gigabit Ethernet

Ethernet transceiver, SFP, RJ-45 connector,


shielded twisted pair. For the applications:

TR-0013

1000BASE-T
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012
nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:

TR-0023

1000BASE-ZX
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:

TR-0029

1000BASE-SX
FC-100/200/400

68

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Item number

Bi-directional Ethernet

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Ethernet WDM

MA364 Rev. E3

69

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

SDH/Ethernet CWDM transceivers, multirate,


available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC connectors, single mode fiber. For the applications:

Item number

TR-0020-xxx

STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm 1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:

TR-0031-xxx

GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
Transceivers for bidirectional SDH/Ethernet
interfaces

The following transceivers are available for the bi-directional SDH/Ethernet


interfaces of the Tellabs 6325 node.
Description

Item number

TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U

70

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Item number

TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Transceivers for Fibre
Channel interfaces

The following transceivers are available for the Fibre Channel interfaces of the
Tellabs 6325 node.
Description

Item number

Fibre Channel

Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011


nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012
nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100

MA364 Rev. E3

71

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Ethernet/Fibre Channel transceiver, multirate,


850 nm, SFP, LC connectors, multi mode fiber.
For the applications:

Item number

TR-0029

1000BASE-SX
FC-100/200/400
TR-0030
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the applications:
FC-100/200/400
Bi-directional Fibre Channel

SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.


For the applications:

TR-0033-D

S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:

TR-0033-U

S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Fibre Channel WDM

Ethernet/Fibre Channel CWDM transceivers,


multirate, available wavelengths are 1471 nm 1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:

TR-0031-xxx

GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.

72

MA364 Rev. E3

Tellabs 6325 Edge Node

2.5

2 Ordering Information for Tellabs 6325 Node

Subrack Items

Subrack items

The following subrack items are available for the Tellabs 6325 node.
Description

Item number

SC2 subrack, one rack unit (1RU) high, four slots UC3560
for traffic modules. The following items are delivered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Ejector tool
M4 x 8 screw and washer to attach ground
wire

2.6

Cover plate for empty slot 2-5 (position for traffic


module)

NS-0292

Cover plate for empty slot 8 (position for PS-DC


module)

NS-0295

Balun Items

Balun items

The following balun items are available for the Tellabs 6325 node.
Description

Item number

120/75 ohm balun, 3 pole IDC (Krone) to BNC


connector, for 2 Mbit/s interface on PIM1m and
SPIMX modules. The balun provides only one
connection. So you need two WK-511B-KIT for a
2 Mbit/s interface, one for input and one for output connections.

WK-511B-KIT

Balun panel kit BNC. Up to 42 baluns can be installed in the panel. The kit contains the following
items:

NS-0299

Balun panel for 19 inch rack


Balun panel for ETSI rack
Metal strap for fastening the cable shield
Screws for installing panel in a rack

MA364 Rev. E3

73

Tellabs 6325 Edge Node

2.7

2 Ordering Information for Tellabs 6325 Node

Cables

Traffic interface cables

The following optical and electrical interface cables are available for the Tellabs 6325 node.
Description

Item number

Optical single mode fiber cables, two fibers in one cable

2xLC to 2xLC single mode fiber cable, 0.3 m

W-OF203/00.3

2xLC to 2xLC single mode fiber cable, 5 m

W-OF203/05.0

2xLC to 2xLC single mode fiber cable, 10 m

W-OF203/10.0

2xLC to 2xLC single mode fiber cable, 20 m

W-OF203/20.0

2xLC to 2xFC/PC single mode fiber cable, 5 m

W-OF204/05.0

2xLC to 2xFC/PC single mode fiber cable, 10 m

W-OF204/10.0

2xLC to 2xFC/PC single mode fiber cable, 20 m

W-OF204/20.0

2xLC to 2xSC single mode fiber cable, 5 m

W-OF205/05.0

2xLC to 2xSC single mode fiber cable, 10 m

W-OF205/10.0

2xLC to 2xSC single mode fiber cable, 20 m

W-OF205/20.0

Optical multi mode fiber cables, two fibers in one cable

2xLC to 2xLC multi mode fiber cable, 5 m

W-OF207/05.0

2xLC to 2xLC multi mode fiber cable, 10 m

W-OF207/10.0

2xLC to 2xLC multi mode fiber cable, 20 m

W-OF207/20.0

Electrical cables

74

1.0/2.3 to 1.0/2.3 coaxial cable, 5 m

WK-482B-05.0-01

1.0/2.3 to 1.0/2.3 coaxial cable, 10 m

WK-482B-10.0-01

1.0/2.3 to 1.0/2.3 coaxial cable, 20 m

WK-482B-20.0-01

1.0/2.3 to BNC coaxial cable, 5 m

WK-483B-05.0-01

1.0/2.3 to BNC coaxial cable, 10 m

WK-483B-10.0-01

1.0/2.3 to BNC coaxial cable, 20 m

WK-483B-20.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 5 m

WK-484B-05.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 10 m

WK-484B-10.0-01

1.0/2.3 to 1.6/5.6 coaxial cable, 20 m

WK-484B-20.0-01

1.0/2.3 to open end coaxial cable, 20 m

WK-497B-20.0-01

MDR to open ended cable, 120 ohm, 5 m

WK-503Y-05.0-12

MDR to open ended cable, 120 ohm, 10 m

WK-503Y-10.0-12

MA364 Rev. E3

Tellabs 6325 Edge Node

2 Ordering Information for Tellabs 6325 Node

Description

Optical Network
Equipment Protection
Cables

MDR to open ended cable, 120 ohm, 20 m

WK-503Y-20.0-12

RJ-45 to open ended cable, 120 ohm, 5 m

WK-504Y-05.0-10

RJ-45 to open ended cable, 120 ohm, 10 m

WK-504Y-10.0-10

RJ-45 to open ended cable, 120 ohm, 20 m

WK-504Y-20.0-10

The following Optical Network Equipment protection cables are available for
the Tellabs 6325 node.
Description

Extraction tool for 1.0/2.3


coaxial cables

W-OF212/05.0

Y-cable (optical splitter), 2xLC to 2x(2xLC) multi


mode fiber cable, 5 m. The Y-cable splits client TX
and RX signals into working and protecting RX
and TX signals.

W-OF213/05.0

The following extraction tool for disconnecting coaxial cables provided with
1.0/2.3 connectors, is available for the Tellabs 6325 node.

Extraction tool for coaxial cables (1.0/2.3)

9 pole D-sub to open ended, 120 ohm, 3 m

TOOL-H030

Item number

WK-502Y-03.0-01

The following management cable is available for the Tellabs 6325 node. For
Ethernet interfaces, use standard STP Ethernet interface cables (RJ-45).
Description

Craft terminal interface cable, RJ-45 to 9 pole Dsub, 3 m

MA364 Rev. E3

Item number

The following synchronization and AUX alarm cable is available for the Tellabs 6325 node.
Description

Management cable

Item number

Y-cable (optical splitter), 2xLC to 2x(2xLC) single


mode fiber cable, 5 m. The Y-cable splits client TX
and RX signals into working and protecting RX
and TX signals.

Description

Synchronization and
AUX alarm cable

Item number

Item number

WK-480X-03.0-01

75

Tellabs 6325 Edge Node

Power cable

2 Ordering Information for Tellabs 6325 Node

The following power cable is available for the Tellabs 6325 node.
Description

3 pole Molex mini-fit to open ended, 2.6 m

Item number

WK-500Z-02.6-01

Note: When using the TR4 or MP4 modules a

high frequency ferrite filter clamp on the power


supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission requirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
EOW cable

The following EOW cable is available for the Tellabs 6325 node.
Note: On the SPIMX module with 21 x 2 Mbit/s the EOW system is connected

with the 2 Mbit/s interface cable (WK-503Y-zz.z-12 - ref. Traffic interface cables on page 74). The open ended cable holds both the connections for the 2 Mbit/s interfaces and the EOW interface.
Cable description

RJ-45 to 15 pole D-sub, 3 m

2.8

WK-501Y-03.0-01

Embedded Software

Embedded software

The following embedded software is available for the Tellabs 6325 node.
Description

76

Item number

Item number

6325 ESW, FP1.4, CD-ROM

SW6325-0014M200

ETEX ESW, CD-ROM

SW-ETEX-M200

MA364 Rev. E3

Tellabs 6325 Edge Node

Index

Index
Numerics

6325 items 11

EMAP 13
Embedded Software
Item number 76
selecting 56
Equipment Protection cables 55
ETEX10S 13
External balun
Selecting 24
Extraction tool for coaxial cables 75

A
Abbreviations 9
AC/DC adapter 11
Alarm cable
item number 75

B
Balun
Item number 73
Selecting 24
Basic Units 11
Item numbers 60

C
Cables
Item numbers 74
selecting 52
selecting alarm 55
selecting EOW 56
selecting for SDH/PDH interfaces 53
selecting management 56
selecting Optical Network Equipment
Protection cables 55
selecting power 56
selecting synchronization 55
type of 52
CMCC 11
Coaxial cable extraction tool 75
Configuration and Ordering Guide
Prerequisite for using 9
Structure 9
Configuring a Tellabs 6325 Node 13
Basic Units 15
Dedicated Units 14
Subrack and Modules 17

D
DC/DC 11
Dedicated Units 11
Item numbers 59
Selecting 14
Document structure 9

MA364 Rev. E3

F
FAN 12

I
Interconnecting nodes 28
Items 11

M
Management cable
Item number 75
MP4 13

N
Network Equipment Protection cables 55

O
OAD1-C 13
OAD1-D 13
OM-C 13
OM-D 13
Optical Amplifiers 52
Optical Network Equipment Protection cables 55

P
PIM1m 12
PIM3P 12
Power cable
Item number 76
Prerequisitefor using this guide 9
Product Release 9
Product version 9
Protection cables 55
PS-DC 11

77

Tellabs 6325 Edge Node

Index

S
SC2 11
Selecting
Cables 52
Embedded software 56
External balun 24
Support modules 18
Traffic modules 19, 28
Transceivers 42
Transceivers for bi-directional interfaces 49
Transceivers for ETEX10S module 46
Transceivers for Ethernet interfaces 46
Transceivers for Fibre Channel interfaces 50
Transceivers for SDH interfaces 42
Transceivers for SIMX and SPIMX modules
and dedicated units 42
Transceivers for STM-1 interfaces 43
Transceivers for STM-16 interfaces 43
Transceivers for STM-4 interfaces 43
SIMX16m 12
SIMX4m 12
Software
Item number 76
SPIMX 12
SPIMX16m-1 12
SPIMXm-1 12
Subrack 11
Items 73
Support modules
item numbers 65
Selecting 18
Synchronization cable
item number 75

T
Tellabs 6325 items 11
TR4 13
Traffic modules
Item numbers 61, 63
Selecting 19, 28
Transceivers
Bi-directional interfaces 49
Ethernet interfaces 46
Fibre Channel interfaces 50
Item numbers 65, 67, 70, 71
SDH interfaces 42
Selecting 42, 46

U
Using optical amplifiers 52

78