Tellabs 6300 Managed Transport System
Tellabs 6300 Managed Transport System
Tellabs 6300 Managed Transport System
Product family
Product name
Document
Legal Notices
Legal Notices
Copyright Statement
This Tellabs manual is owned by Tellabs or its licensors and protected by U.S.
and international copyright laws, conventions, and treaties. Your right to use
this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws. Unauthorized reproduction, modification, distribution, display or other use of this manual may result in criminal and civil
penalties.
Trademark Notice
The following trademarks and service marks are owned by Tellabs Operations, Inc., or its affiliates in the United States and/or other countries: AUDIO
PLUS, CABLESPAN, CEC-128, DYNAMIC SIGNAL TRANSFER,
DXX, DXX logo, EC DUO, ENHANCED AUDIO PLUS, EXPRESS/PATH, FOCUS, MARTIS, MARTISDXX, MARTIS logo, MARTISDXX logo, METROVANTAGE, METROWATCH, NETREACH,
NETWISE, SCULPTURED SOUND, TELLABS, TELLABS and T symbol, T symbol, TELLABS PROPARTNER, TEL/MAP, TEL/MOR, THE
WORLD COMMUNICATES THROUGH TELLABS, TITAN, VERITY,
YOUR NETWORKING PARTNER.
Any other company or product names may be trademarks of their respective
companies.
MA364 Rev. E3
Environmental Notices
Environmental Notices
Instructions for use,
maintenance and
management of residual
product
The equipment covered in this manual has been designed to fulfil the environmental demands of market and society. There are no apparent hazards during
use and on-site maintenance of the equipment. We recommend that repair of
defective equipment takes place at Tellabs premises, and it is likewise recommended to dispose of the equipment by use of certified local waste contractors
that can assure environmental safe handling and disposal of the equipment.
Arrangement for disposal of equipment can also be made through Tellabs.
Waste handling in
member states of the
European Union
Label
The equipment is marked with the figure shown below, to indicate that the
equipment must be collected separately. In case of very small products, the
figure may only be on the packaging or in this manual. The Tellabs name and
the production date will also be labelled on the product.
Further information
For further information about separation and handling the disposed equipment to ensure correct reuse or recycling, please look at www.tellabs.com.
MA364 Rev. E3
Revision Information
Revision Information
Revision history
Date
Description of Changes
A1
A2
B1
B2
C1
C2
MA364 Rev. E3
Rev.
D1
Date
Revision Information
Description of Changes
D2
D3
May 5, 2009
E1
E2
E3
MA364 Rev. E3
Revision Information
MA364 Rev. E3
Contents
Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1
1.6
1.7
1.8
1.9
Dedicated Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Basic Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Subrack Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Balun Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Embedded Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MA364 Rev. E3
77
Contents
MA364 Rev. E3
Preface
Preface
Purpose
This guide assumes that information from the network planning process is
available.
Product version
Structure of the
configuration and
ordering guide
This guide is meant as a supplement to the Tellabs 6325 node configurator tool
and vice versa.
Abbreviations used in
this guide
3R
ADM
CMCC
CT
CTE
CWDM
DC/DC
DWDM
E1
EMAP
EOW
ETEX
FE
FP
GbE
Km
Mbit/s
MP
MS-SPRing
NE
nm
NM
OAD
OM
PDH
PIM
ps
PS-DC
SDXC
SETS
SFP
MA364 Rev. E3
SIMXm
SNC/I
SNC/N
SPIMX
SPIMXm
STM
STP
SW
TR
TRIB
VC-4
VC-12
WDM
XC
References to Tellabs
documents
10
Preface
MA364 Rev. E3
Overview
1.1
Available items
Dedicated Units
Description
MA364 Rev. E3
Basic Unit
SC2
CMCC
PS-DC
AC/DC
11
Item
FAN
Description
SIMX4m
SDH interface module, cross-connect and NE synchronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
4 x STM-1/STM-4 (with SFP)
SIMX16m
SDH interface module, cross-connect and NE synchronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)
SPIMX
SPIMXm-1
SPIMX16m-1
PIM1m
PIM3P
12
MA364 Rev. E3
Item
Description
ETEX10S
EMAP
1.2
OM-C
OM-D
OAD1-C
OAD1-D
TR4
MP4
Transceivers
Baluns
MA364 Rev. E3
There are three ways to configure the Tellabs 6325 node. They are as follows:
If
then
13
If
then
1.3
To configure a Tellabs
6325 node with a
dedicated unit
This procedure describes how to configure a Tellabs 6325 node with one of the
dedicated units of the Tellabs 6325 node.
Step
Action
Select the dedicated unit that fits your required application. The
units are listed in Item numbers of the dedicated units on page 14.
Select the cables as described in 1.8 Selecting the Cables on page 52.
Note: Two DC power cables are included when you order the dedi-
Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.
Item number
14
MA364 Rev. E3
Description
Item number
1.4
To configure a Tellabs
6325 node with a basic
unit
Action
Select the basic unit that fits your required application. The units are
listed in Item numbers of the basic units on page 16.
If you want to add traffic modules to the basic unit then go to Selecting additional modules on page 22.
Select the cables as described in 1.8 Selecting the Cables on page 52.
Note: Two DC power cables are included when you order the basic
unit (CU...).
6
MA364 Rev. E3
Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.
15
Item number
CU3560-001-A
1x SC2 subrack
1x SIMX4m module providing 4 x STM1/STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
CU3560-003
1x SC2 subrack
1x SPIMX module providing 2 x STM-1/STM4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
CU3560-005-C
1x SC2 subrack
1x SPIMXm-1 module providing 2 x STM1/STM-4 (with SFP) and 21 x 2 Mbit/s
120 Ohm, slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
16
MA364 Rev. E3
Description
Item number
CU3560-006-A
1x SC2 subrack
2x SIMX16m module each providing 1 x STM16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:
CU3560-007
1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable
1.5
To configure a Tellabs
6325 node
Action
If you require a WDM stand-alone configuration then select the traffic modules as described in 1.5.3 Selecting the Traffic Modules for
the Tellabs 6325 Node - WDM Stand-alone Configurations on page
28.
WDM stand-alone configurations are Tellabs 6325 nodes with only
WDM modules installed. These configurations are also referred to as
Tellabs 6325 Wavelength Division Multiplexing nodes.
MA364 Rev. E3
17
1.5.1
Step
Action
Select the cables as described in 1.8 Selecting the Cables on page 52.
Select the embedded software as described in 1.9 Selecting the Embedded Software on page 56.
Selecting the Subrack and Support Modules for the Tellabs 6325 Node
The SC2 subrack is a front access subrack comprising 9 slots for modules.
In any configuration you need a subrack and support modules. Select the following items. See also information about item numbering in connection with
the change of manufacturing process. Refer to Lead Free Soldering on page
61.
Description
Item number
SC2 subrack, one rack unit (1RU) high, four slots UC3560
for traffic modules. The following items are delivered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Ejector tool
M4 x 8 screw and washer to attach ground
wire
18
FAN module
CM3565
CM3564
Power module(s)
MA364 Rev. E3
then
Common items
1.5.2
Selecting the Traffic Modules for the Tellabs 6325 Node - SDH
Configurations
MA364 Rev. E3
Follow this procedure to select the traffic modules for SDH configurations.
19
The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
Step
Action
Select the module to perform the cross-connect and NE synchronization (SETS) functions. The module is located in slot 3 of the subrack.
Described in Selecting the module to perform the cross-connect and
NE synchronization (SETS) functions on page 20.
function of all E1/P12s in the network element. If you require the nonintrusive monitoring function, then you must select a SIMX4m,
SIMX16m, SPIMXm-1 or SPIMX16m-1 module for slot 3 (and 2). The
monitoring function is not supported in the SPIMX module with four
2 Mbit/s (CM3563).
If
and
up to four STM-1/
STM-4 interfaces
one STM-1/STM-4
interface
up to 21 x 2 Mbit/s
interfaces
20
then
MA364 Rev. E3
If
and
then
select the SPIMX module and add SFP transceivers. See also Selecting external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.
up to 21 x 2 Mbit/s interfaces
The module that performs the protection of the cross-connect and NE synchronization (SETS) functions is located in slot 2. Depending on which type of
aggregate and tributary signals required in the network element different
modules can be selected. Follow this procedure to select the module.
Note: The module types in slot 2 and 3 do not necessarily have to be the same
and
up to four STM-1/
STM-4 interfaces
one STM-1/STM-4
interface
up to 21 x 2 Mbit/s
interfaces
MA364 Rev. E3
then
21
If
Selecting additional
modules
and
then
select the SPIMX module and add SFP transceivers. See also Selecting external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.
up to 21 x 2 Mbit/s interfaces
In addition to the interfaces present on the module you have selected performing the cross-connect and NE synchronization (SETS) functions (slot 3) and, if
required, protection of the cross-connect and NE synchronization (SETS)
functions (slot 2), modules can be installed in slot (2), 4 and 5 to extend the
number of interfaces. When the module for slot 3 (and 2) has been selected,
then calculate the number of additional interfaces your configuration requires. Then select the type and number of modules that fits your configuration. The type of modules to provide additional interfaces are as follows:
Note: The cross-connect function in slot 3 (and 2) supports the STM-1/4 inter-
SIMX16m
Interfaces
Slot
2, 4, 5
1 x STM-1/STM-4/STM-16 (with
SFP)
2, 4, 5
2, 4, 5
22
2, 4, 5
MA364 Rev. E3
Module
PIM3P
Interfaces
Slot
2, 4, 5
4+5
2 x FE (with SFP)
4 x FE (RJ-45)
EMAP
2 x FE (RJ-45)
2, 4, 5
2, 4, 5
8 channel CWDM multiplexer and demultiplexer module. The channel wavelengths are 1471, 1491, 1511, 1531, 1551,
1571, 1591 and 1611 nm
OM-D
8 channel DWDM multiplexer and demultiplexer module. The channel frequencies are 192.9, 193.0, 193.1, 193.2,
193.3, 193.4, 193.5 and 193.6 THz
2, 4, 5
OAD1-C
2, 4, 5
OAD1-D
2, 4, 5
TR4
2, 4, 5
2 and 5
4 and 5
MP4
For systems with WDM modules see also WDM configurations on page 29.
MA364 Rev. E3
23
with slot 2, then slot 4 and then slot 5. When you install PIM1m modules it is recommended to start with slot 5, then slot 4 and then slot 2.
However if your configuration requires an ETEX10S module the
PIM1m module can only be placed in slot 2.
Selecting external balun
to provide 2 Mbit/s
75 ohm interface
The 2 Mbit/s interfaces on the SPIMX and PIM1m modules are 120 ohm interfaces. If your configuration requires 75 ohm interfaces you must add the following items:
two external 120/75 ohm baluns per 2 Mbit/s interface. The balun has a
BNC connector and has to be installed in a balun panel. The balun item
number is WK-511B-KIT.
a balun panel kit BNC (item number NS-0299). Up to 42 baluns can be installed in the balun panel.
an open ended cable as used for the 120 ohm interface. See Electrical cables - 120 ohm on page 54.
The balun WK-511B-KIT provides only one connection. So you need two WK511B-KIT for a 2 Mbit/s interface, one for input and one for output connections.
Select from the following traffic modules. See also information about item
numbering in connection with the change of manufacturing process. Refer to
Lead Free Soldering on page 61.
Description
Item number
SDH / PDH
CM3568-A
CM3567-A
24
MA364 Rev. E3
Description
Item number
CM3575-A
CM3574-B
CM3563
CM3579
ternal balun.
Ethernet
MA364 Rev. E3
25
Description
Item number
CM3580D
26
CM3581C-471
CM3581C-491
CM3581C-511
CM3581C-531
CM3581C-551
CM3581C-571
CM3581C-591
CM3581C-611
CM3581D-290
CM3581D-300
CM3581D-310
CM3581D-320
CM3581D-330
CM3581D-340
CM3581D-350
MA364 Rev. E3
Description
Item number
CM3581D-360
Transponder/repeater/muxponder
CM3582
CM3585
NS-0292
MA364 Rev. E3
Item number
SC2 subrack
UC3560
FAN
CM3565
CMCC
CM3564
2 x PS-DC
CM3561-A
27
Description
Item number
2 x SIMX16m
CM3568-A
ETEX10S
CM3572
Interconnecting Tellabs
6325 nodes to extend
number of interfaces
1.5.3
Selecting the Traffic Modules for the Tellabs 6325 Node - WDM Standalone Configurations
Follow this procedure to select the traffic modules for WDM stand-alone configurations. These configurations are also referred to as Tellabs 6325 Wavelength Division Multiplexing nodes.
The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
Step
1
Action
Select the required WDM configuration as described in WDM configurations on page 29.
See also 1.5.4 Optical Network Equipment Protection on page 36
and 1.5.5 WDM Link Design on page 39.
28
Select the traffic modules as described in Selecting the WDM modules on page 33.
MA364 Rev. E3
Step
WDM configurations
Action
The following WDM configurations are possible with the Tellabs 6325 node.
If
then
MA364 Rev. E3
29
If
then
you require a
1-channel
CWDM
add/drop
multiplexer
30
MA364 Rev. E3
If
MA364 Rev. E3
then
you require a
1-channel
DWDM
add/drop
multiplexer
you require a
4-channel
transponder/
repeater
select the TR4 module and add SFP transceivers. See also
Using the MP4/TR4 module on page 33.
31
32
If
then
you require a
4-channel
muxponder/
transponder/
repeater
select the MP4 module and add SFP transceivers. The MP4
module can operate in the following three configurations
controlled by the management software. See also Using
the MP4/TR4 module on page 33.
MA364 Rev. E3
Port connections
1 2, 3
56
78
MA364 Rev. E3
1 2, 3
5 4, 6
78
Select the type and number of modules that fits your configuration. The type
of modules are as follows:
33
Interfaces
Slot
OM-C
2, 3, 4, 5
OM-D
2, 3, 4, 5
OAD1-C
1 channel CWDM optical add/drop multiplexer module. Select between the following add/drop channel wavelengths: 1471,
1491, 1511, 1531, 1551, 1571, 1591 and 1611
nm
2, 3, 4, 5
OAD1-D
TR4
2, 3, 4, 5
4 channel WDM transponder/repeater
module. A maximum of two TR4/MP4
modules can be installed in a subrack. If
the configuration requires two modules
then use one of the following slot combinations:
2 and 3
2 and 5
3 and 4
4 and 5
MP4
4 channel WDM muxponder/transponder/repeater module with NE synchronization (SETS) function. A maximum of two
TR4/MP4 modules can be installed in a
subrack. If the configuration requires two
modules then use one of the following slot
combinations:
2, 3, 4, 5
2 and 3
2 and 5
3 and 4
4 and 5
Note: The MP4 module must be installed in
34
MA364 Rev. E3
Select from the following traffic modules. See also information about item
numbering in connection with the change of manufacturing process. Refer to
Lead Free Soldering on page 61.
Description
Item number
Optical multiplexer/demultiplexer
CM3580D
MA364 Rev. E3
CM3581C-471
CM3581C-491
CM3581C-511
CM3581C-531
CM3581C-551
CM3581C-571
CM3581C-591
CM3581C-611
CM3581D-290
CM3581D-300
CM3581D-310
CM3581D-320
CM3581D-330
CM3581D-340
CM3581D-350
35
Description
Item number
CM3581D-360
Transponder/repeater/muxponder
CM3582
1.5.4
Introduction
NS-0292
Description
The signal is split at the Y-cable and one copy of the signal is directed to a pre
defined facility on each module, resulting in a working signal and a protecting
signal. The two signals are then typically forwarded through the network via
different physical paths.
On the destination side, the signals are received by the muxponder/transponder modules, compared for integrity, and one is forwarded to the targeted client. However, in line-to-client port direction, the client port lasers on each
transponder are combined together. Only the client port side laser of the Active muxponder/transponder facility is turned on and transmits the signal to-
36
MA364 Rev. E3
The following picture shows an example of Optical Network Equipment protection for MP4 and TR4.
Follow this procedure to select the required items for Optical Network Equipment protection:
Step
MA364 Rev. E3
Action
Select the MP4/TR4 modules required for your specific configuration including modules for protection.
37
38
Step
Action
Select one Y-cable per client interface. See 1.8.2 Selecting the Optical
Network Equipment Protection Cables on page 55.
MA364 Rev. E3
1.5.5
Introduction
Point to Point
configuration
Make a power budget for a point-to-point link with either STM-16 CWDM or
STM-16 DWDM as shown in the following tables.
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
4.0
dB
Path penalty
2.0
dB
22.0
dB
MA364 Rev. E3
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
6.0
dB
Path penalty
2.0
dB
20.0
dB
39
Optical Add/Drop
configuration with OAD
module
Make a power budget for an optical Add/Drop link (with OAD module) with
either STM-16 CWDM or STM-16 DWDM as shown in the following tables.
Power budget for an optical Add/Drop link (with OAD module) with STM16 CWDM.
Parameter
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
4.0
dB
2.0
dB
Path penalty
2.0
dB
20.0
dB
Power budget for an optical Add/Drop link (with OAD module) with STM16 DWDM
Parameter
40
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
6.0
dB
3.0
dB
Path penalty
2.0
dB
17.0
dB
MA364 Rev. E3
Make a power budget for an optical Add/Drop back-to-back link with either
STM-16 CWDM or STM-16 DWDM as shown in the following tables.
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
4.0
dB
4.0
dB
Path penalty
2.0
dB
18.0
dB
MA364 Rev. E3
Value
Unit
0.0
dBm
Receive sensitivity
-28.0
dBm
6.0
dB
6.0
dB
Path penalty
2.0
dB
14.0
dB
41
1.6
Overview
1.6.1
Selecting transceivers
for the SIMX and SPIMX
modules and the
Dedicated Units
The dispersion characteristics and attenuation for each specific interface is determined by an application code of the transceivers.
Note: If your configuration requires an optical amplifier, then go to 1.7 Using
electrical STM-1
then
two connectors together, on the cables for the electrical STM-1 interface, are a little wider than the
transceiver. Due to this it will not be possible to install two electrical STM-1 transceivers in the cages
next to one another on the Dedicated Units. It
might (depending on the connector type) also be
difficult to replace a transceiver in neighbor position to an electrical STM-1 transceiver, without
disconnecting the electrical cables on the neighbor
position. This is the case only with the Dedicated
Units. On the SIMX4m, SIMX16m and SPIMX
modules the space between the cages makes it
possible to install electrical STM-1 transceivers in
all STM-1/4 cages.
42
optical STM-1
STM-4
STM-16
MA364 Rev. E3
Selecting transceivers
for optical STM-1
interface
The type of transceivers that you select for the optical STM-1 interface, is determined by the transmission wavelength and the attenuation of the fibre connection to the neighboring NE. The attenuation parameter is found by making
a power budget for the system.
if transmission wavelength is
Selecting transceivers
for STM-4 interface
then
attenuation is 0-12 dB
attenuation is 10-28 dB
attenuation is 10-28 dB
attenuation is 15-33 dB
The type of transceivers that you select for the STM-4 interface, is determined
by the transmission wavelength and the attenuation characteristics of the fibre
connection to the neighboring NE. The attenuation parameters is found by
making a power budget for the system.
and If point S-R specification
then
attenuation is 0-12 dB
attenuation is 10-24 dB
attenuation is 10-24 dB
The type of transceivers that you select for STM-16 interface, is determined by
the transmission wavelength, attenuation and the dispersion characteristics of
the fibre connection to the neighboring NE. The attenuation and dispersion
parameters are found by making a power budget for the system.
if transmission wavelength is
MA364 Rev. E3
if transmission wavelength is
Selecting transceivers
for STM-16 interface
then
attenuation is 0-12 dB
attenuation is 10-24 dB
attenuation is 10-24 dB
and dispersion is <1600
ps/nm
wavelength specific
(CWDM)
attenuation is 12-24 dB
and dispersion is <1600
ps/nm
43
if transmission wavelength is
wavelength specific
(DWDM)
Item numbers of
transceivers
attenuation is 10-26 dB
and dispersion is <2400
ps/nm
then
Item number
SDH
TR-0021
STM-1 electrical
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0001
S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0002
L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0003
L-1.2
FE
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0019-551
V-1.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0004
S-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0005
L-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0006
L-4.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0007
S-16.1
44
MA364 Rev. E3
Description
Item number
TR-0008
L-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0009
L-16.2
Bi-directional SDH
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
SDH WDM
MA364 Rev. E3
45
Description
Item number
TR-0020-xxx
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
1.6.2
Transceivers for
Ethernet interfaces
Item number
Fast Ethernet
TR-0027
10/100BASE-T
Ethernet transceiver, SFP, LC connectors, multi
mode fiber. For the applications:
TR-0010
100BASE-FX
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0022
100BASE-LX10
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0001
S-1.1
FE
46
MA364 Rev. E3
Description
Item number
TR-0002
L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0003
L-1.2
FE
Gigabit Ethernet
TR-0013
1000BASE-T
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012
nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0023
1000BASE-ZX
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
TR-0029
1000BASE-SX
FC-100/200/400
Bi-directional Ethernet
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
MA364 Rev. E3
47
Description
Item number
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Ethernet WDM
TR-0020-xxx
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
48
MA364 Rev. E3
Description
Item number
TR-0031-xxx
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
1.6.3
If you want to send traffic in both directions using only one fiber then select
the bi-directional transceivers. Select a set of transceivers (-D/-U). The Dtransceiver transmitting at 1550nm (1490nm for TR-0033-D) is used in one end
of the fiber and the U-transceiver transmitting at 1310nm (1570nm for TR0033-U) is used at the other end of the fiber.
The attenuation range for the STM-1 transceivers is 0-13 dB and the attenuation range for the STM-4 transceivers is 0-10 dB.
Item number
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
MA364 Rev. E3
49
Item number
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
Transceivers for STM-16
/ 1000BASE-BX / FC100/200 bi-directional
interfaces
Item number
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
1.6.4
Item number
Fibre Channel
50
MA364 Rev. E3
Description
Item number
TR-0029
1000BASE-SX
FC-100/200/400
TR-0030
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the applications:
FC-100/200/400
Bi-directional Fibre Channel
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Fibre Channel WDM
TR-0031-xxx
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
MA364 Rev. E3
51
1.7
Introduction
For a standard G.957 L-16.2 interface the distance between two nodes are limited to 80 km over a standard G.652 fiber. To reach longer distances, it is necessary to add a re-generator in the middle of the span, boost the output level
and/or improve the sensitivity of the receiver.
Using an external Optical Amplifier it is possible to increase the distance between two Tellabs 63xx nodes up to approx. 180 km depending on actual loss
and dispersion of the link.
Using optical amplifiers to increase the distance between Tellabs 63xx Nodes
is described in an application note [1].
1.8
The following type of cables are used for a Tellabs 6325 node.
Cables
Used for
52
Synchronization and
alarm cables
Management cables
Power cables
EOW cables
MA364 Rev. E3
1.8.1
Overview
Dedicated Unit
SIMX
Interface
electrical STM-1
SPIMX
MA364 Rev. E3
PIM3P
34/45 Mbit/s
PIM1m
ETEX10S, EMAP
optical
electrical
optical
Cables
53
Item number
W-OF203/00.3
W-OF203/05.0
W-OF203/10.0
W-OF203/20.0
W-OF204/05.0
W-OF204/10.0
W-OF204/20.0
W-OF205/05.0
W-OF205/10.0
W-OF205/20.0
W-OF207/05.0
W-OF207/10.0
W-OF207/20.0
For SPIMX and PIM1m modules and Dedicated Units with 2 Mbit/s 120 ohm
interfaces, select between the following cables.
Description
Item number
WK-504Y-05.0-10
WK-504Y-10.0-10
WK-504Y-20.0-10
Cables for PIM1m, SPIMX modules with 21 x 2 Mbit/s and Dedicated Units
54
WK-503Y-05.0-12
WK-503Y-10.0-12
WK-503Y-20.0-12
For electrical STM-1 interfaces and 34/45 Mbit/s 75 ohm interfaces select between the following cables.
MA364 Rev. E3
Note: For easier removal of the coaxial cables, an extraction tool (item number
1.8.2
WK-482B-05.0-01
WK-482B-10.0-01
WK-482B-20.0-01
WK-483B-05.0-01
WK-483B-10.0-01
WK-483B-20.0-01
WK-484B-05.0-01
WK-484B-10.0-01
WK-484B-20.0-01
WK-497B-20.0-01
Equipment protection
cables
Select from the following equipment protection cables. You require one Y-cable per client interface. The cable connects TX signals and RX signals for both
working and protection signals. See the description in 1.5.4 Optical Network
Equipment Protection on page 36.
Description
1.8.3
Item number
Item number
W-OF212/05.0
W-OF213/05.0
Synchronization and
AUX alarm interface
cable
If you require a 2 MHz external synchronization input signal or synchronization output signal, then select the following cable. This cable also connect to
four AUX alarms.
Note: The plug type on the module is 9 pole D-Sub.
Description
MA364 Rev. E3
Item number
WK-502Y-03.0-01
55
1.8.4
If your network element requires connection to a craft terminal, then select the
following cable. You require one cable per craft terminal.
Description
1.8.5
Item number
WK-480X-03.0-01
Power cable
Description
Item number
WK-500Z-02.6-01
1.8.6
EOW cables
If your system includes an EOW system, then select the following cable.
Note: On the SPIMX modules with 21 x 2 Mbit/s the EOW system is connect-
1.9
WK-501Y-03.0-01
Embedded software
56
Item number
The Tellabs 6325 node (CMCC module) is delivered with an embedded software release pre-installed. The pre-installed ESW may be different from the
release you require for your configuration. Therefore it is recommended to order the CD-ROM with the ESW separately. ETEX modules are delivered with
MA364 Rev. E3
an ETEX ESW release pre-installed. The pre-installed ETEX ESW may be different from the release you require for your configuration. Therefore it is recommended to order the CD-ROM with the ETEX ESW separately.
Description
MA364 Rev. E3
Item number
SW6325-0014M200
SW-ETEX-M200
57
58
MA364 Rev. E3
Overview
2.1
Dedicated Units
Dedicated units
Item number
MA364 Rev. E3
59
2.2
Basic Units
Basic units
The following pre-configured Tellabs 6325 node basic units are available.
Description
Item number
CU3560-001-A
1x SC2 subrack
1x SIMX4m module providing 4 x STM1/STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
CU3560-003
1x SC2 subrack
1x SPIMX module providing 2 x STM-1/STM4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
CU3560-005-C
1x SC2 subrack
1x SPIMXm-1 module providing 2 x STM1/STM-4 (with SFP) and 21 x 2 Mbit/s 120
Ohm, slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
60
MA364 Rev. E3
Description
Item number
CU3560-006-A
1x SC2 subrack
2x SIMX16m module each providing 1 x STM16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:
CU3560-007
1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable
2.3
Modules
The following SDH and PDH modules are available for the Tellabs 6325 node.
Description
Item number
CM3568-A
MA364 Rev. E3
61
Description
Item number
CM3567-A
CM3575-A
CM3574-B
CM3563
CM3579
ternal balun.
Cover plate for empty slot 2-5 (position for traffic
module)
62
NS-0292
MA364 Rev. E3
Ethernet modules
The following Ethernet modules are available for the Tellabs 6325 node.
Description
Item number
NS-0292
The following WDM modules are available for the Tellabs 6325 node.
Description
Item number
Optical multiplexer/demultiplexer
CM3580D
MA364 Rev. E3
CM3581C-471
CM3581C-491
CM3581C-511
CM3581C-531
CM3581C-551
CM3581C-571
CM3581C-591
CM3581C-611
CM3581D-290
63
Description
Item number
CM3581D-300
CM3581D-310
CM3581D-320
CM3581D-330
CM3581D-340
CM3581D-350
CM3581D-360
Transponder/repeater/muxponder
CM3582
64
NS-0292
MA364 Rev. E3
Support modules
The following support modules are available for the Tellabs 6325 node.
Description
2.4
Item number
PS-DC module
CM3561-A
AC/DC adapter
CM3569
CM3564
FAN module
CM3565
NS-0295
Transceivers
The following transceivers are available for the SDH interfaces of the Tellabs
6325 node.
Description
Item number
SDH
TR-0021
STM-1 electrical
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0001
S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0002
L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0003
L-1.2
FE
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0019-551
V-1.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0004
S-4.1
MA364 Rev. E3
65
Description
Item number
TR-0005
L-4.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0006
L-4.2
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0007
S-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0008
L-16.1
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0009
L-16.2
Bi-directional SDH
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
66
MA364 Rev. E3
Description
Item number
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
SDH WDM
TR-0020-xxx
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
Transceivers for
Ethernet interfaces
The following transceivers are available for the Ethernet interfaces of the Tellabs 6325 node.
Description
Item number
Fast Ethernet
TR-0027
10/100BASE-T
MA364 Rev. E3
67
Description
Item number
TR-0010
100BASE-FX
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0022
100BASE-LX10
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0001
S-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0002
L-1.1
FE
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
TR-0003
L-1.2
FE
Gigabit Ethernet
TR-0013
1000BASE-T
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0011
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
Ethernet/Fibre Channel transceiver, SFP, LC con- TR-0012
nectors, multi/single mode fiber. For the applications:
1000BASE-LX10
FC-100
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
TR-0023
1000BASE-ZX
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
TR-0029
1000BASE-SX
FC-100/200/400
68
MA364 Rev. E3
Description
Item number
Bi-directional Ethernet
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Ethernet WDM
MA364 Rev. E3
69
Description
Item number
TR-0020-xxx
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm 1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:
TR-0031-xxx
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0018-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC connectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
Transceivers for bidirectional SDH/Ethernet
interfaces
Item number
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.2
100BASE-BX-D
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-1.1
100BASE-BX-U
70
MA364 Rev. E3
Description
Item number
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.2
1000BASE-BX-D
TR-0026-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applications:
S-4.1
1000BASE-BX-U
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Transceivers for Fibre
Channel interfaces
The following transceivers are available for the Fibre Channel interfaces of the
Tellabs 6325 node.
Description
Item number
Fibre Channel
MA364 Rev. E3
71
Description
Item number
TR-0029
1000BASE-SX
FC-100/200/400
TR-0030
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the applications:
FC-100/200/400
Bi-directional Fibre Channel
TR-0033-D
S-16.2 (1490nm)
1000BASE-BX-D
FC-100/200
SDH/Ethernet/Fibre Channel transceiver, Bi-directional, SFP, LC connectors, single mode fiber.
For the applications:
TR-0033-U
S-16.2 (1570nm)
1000BASE-BX-U
FC-100/200
Fibre Channel WDM
TR-0031-xxx
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
72
MA364 Rev. E3
2.5
Subrack Items
Subrack items
The following subrack items are available for the Tellabs 6325 node.
Description
Item number
SC2 subrack, one rack unit (1RU) high, four slots UC3560
for traffic modules. The following items are delivered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Ejector tool
M4 x 8 screw and washer to attach ground
wire
2.6
NS-0292
NS-0295
Balun Items
Balun items
The following balun items are available for the Tellabs 6325 node.
Description
Item number
WK-511B-KIT
Balun panel kit BNC. Up to 42 baluns can be installed in the panel. The kit contains the following
items:
NS-0299
MA364 Rev. E3
73
2.7
Cables
The following optical and electrical interface cables are available for the Tellabs 6325 node.
Description
Item number
W-OF203/00.3
W-OF203/05.0
W-OF203/10.0
W-OF203/20.0
W-OF204/05.0
W-OF204/10.0
W-OF204/20.0
W-OF205/05.0
W-OF205/10.0
W-OF205/20.0
W-OF207/05.0
W-OF207/10.0
W-OF207/20.0
Electrical cables
74
WK-482B-05.0-01
WK-482B-10.0-01
WK-482B-20.0-01
WK-483B-05.0-01
WK-483B-10.0-01
WK-483B-20.0-01
WK-484B-05.0-01
WK-484B-10.0-01
WK-484B-20.0-01
WK-497B-20.0-01
WK-503Y-05.0-12
WK-503Y-10.0-12
MA364 Rev. E3
Description
Optical Network
Equipment Protection
Cables
WK-503Y-20.0-12
WK-504Y-05.0-10
WK-504Y-10.0-10
WK-504Y-20.0-10
The following Optical Network Equipment protection cables are available for
the Tellabs 6325 node.
Description
W-OF212/05.0
W-OF213/05.0
The following extraction tool for disconnecting coaxial cables provided with
1.0/2.3 connectors, is available for the Tellabs 6325 node.
TOOL-H030
Item number
WK-502Y-03.0-01
The following management cable is available for the Tellabs 6325 node. For
Ethernet interfaces, use standard STP Ethernet interface cables (RJ-45).
Description
MA364 Rev. E3
Item number
The following synchronization and AUX alarm cable is available for the Tellabs 6325 node.
Description
Management cable
Item number
Description
Synchronization and
AUX alarm cable
Item number
Item number
WK-480X-03.0-01
75
Power cable
The following power cable is available for the Tellabs 6325 node.
Description
Item number
WK-500Z-02.6-01
The following EOW cable is available for the Tellabs 6325 node.
Note: On the SPIMX module with 21 x 2 Mbit/s the EOW system is connected
with the 2 Mbit/s interface cable (WK-503Y-zz.z-12 - ref. Traffic interface cables on page 74). The open ended cable holds both the connections for the 2 Mbit/s interfaces and the EOW interface.
Cable description
2.8
WK-501Y-03.0-01
Embedded Software
Embedded software
The following embedded software is available for the Tellabs 6325 node.
Description
76
Item number
Item number
SW6325-0014M200
SW-ETEX-M200
MA364 Rev. E3
Index
Index
Numerics
6325 items 11
EMAP 13
Embedded Software
Item number 76
selecting 56
Equipment Protection cables 55
ETEX10S 13
External balun
Selecting 24
Extraction tool for coaxial cables 75
A
Abbreviations 9
AC/DC adapter 11
Alarm cable
item number 75
B
Balun
Item number 73
Selecting 24
Basic Units 11
Item numbers 60
C
Cables
Item numbers 74
selecting 52
selecting alarm 55
selecting EOW 56
selecting for SDH/PDH interfaces 53
selecting management 56
selecting Optical Network Equipment
Protection cables 55
selecting power 56
selecting synchronization 55
type of 52
CMCC 11
Coaxial cable extraction tool 75
Configuration and Ordering Guide
Prerequisite for using 9
Structure 9
Configuring a Tellabs 6325 Node 13
Basic Units 15
Dedicated Units 14
Subrack and Modules 17
D
DC/DC 11
Dedicated Units 11
Item numbers 59
Selecting 14
Document structure 9
MA364 Rev. E3
F
FAN 12
I
Interconnecting nodes 28
Items 11
M
Management cable
Item number 75
MP4 13
N
Network Equipment Protection cables 55
O
OAD1-C 13
OAD1-D 13
OM-C 13
OM-D 13
Optical Amplifiers 52
Optical Network Equipment Protection cables 55
P
PIM1m 12
PIM3P 12
Power cable
Item number 76
Prerequisitefor using this guide 9
Product Release 9
Product version 9
Protection cables 55
PS-DC 11
77
Index
S
SC2 11
Selecting
Cables 52
Embedded software 56
External balun 24
Support modules 18
Traffic modules 19, 28
Transceivers 42
Transceivers for bi-directional interfaces 49
Transceivers for ETEX10S module 46
Transceivers for Ethernet interfaces 46
Transceivers for Fibre Channel interfaces 50
Transceivers for SDH interfaces 42
Transceivers for SIMX and SPIMX modules
and dedicated units 42
Transceivers for STM-1 interfaces 43
Transceivers for STM-16 interfaces 43
Transceivers for STM-4 interfaces 43
SIMX16m 12
SIMX4m 12
Software
Item number 76
SPIMX 12
SPIMX16m-1 12
SPIMXm-1 12
Subrack 11
Items 73
Support modules
item numbers 65
Selecting 18
Synchronization cable
item number 75
T
Tellabs 6325 items 11
TR4 13
Traffic modules
Item numbers 61, 63
Selecting 19, 28
Transceivers
Bi-directional interfaces 49
Ethernet interfaces 46
Fibre Channel interfaces 50
Item numbers 65, 67, 70, 71
SDH interfaces 42
Selecting 42, 46
U
Using optical amplifiers 52
78