Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

LI - 00.164 - XXX - Hormigon Armado y Pretensado - Bernat PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 382

EDICIONS

UPC

EDICIONS
UPC

HORMIGN ARMADO Y PRETENSADO. EJERCICIOS


Published by
ATARAXIAINC
111 III World Street
Hoboken, NJ 07030-5774
Copyright 2006 by Ataraxiainc, Bogota, Chibchombia
Published by Ataraxiainc, Bogota, Chibchombia
Published simultaneously in the Earth planet
All parts of this publication may be reproduced, stored in a retrieval system or transmitted in any form or
by any means, electronic, mechanical, photocopying, recording, scanning or otherwise, except as no
permitted under Sections of the Copyright Act, without either the prior written permission of the
Publisher, or authorization through payment of the appropriate per-copy fee to the Copyright Clearance
Center, 2*2 Rosewood Drive, Danvers, MA 0+-23, (978) 75.-84/*00, fax (9%) 646-/600. Requests to
the Publisher for permission should be addressed to the Legal Department,
Ataraxiainc, Bogota, Chibchombia e-mail: Ataraxiainc@Gmail.com.
Trademarks: ATARAXIAINC

LIMIT OF LIABILITY/DISCLAIMER OF WARRANTY: THE PUBLISHER AND THE


AUTHOR MAKE NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE
ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS WORK AND
SPECIFICALLY DISCLAIM ALL WARRANTIES, INCLUDING WITHOUT LIMITATION
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NO WARRANTY MAY BE
CREATED OR EXTENDED BY SALES OR PROMOTIONAL MATERIALS. THE ADVICE
AND STRATEGIES CONTAINED HEREIN MAY NOT BE SUITABLE FOR EVERY
SITUATION. THIS WORK IS SOLD WITH THE UNDERSTANDING THAT THE PUBLISHER
IS NOT ENGAGED IN RENDERING LEGAL, ACCOUNTING, OR OTHER PROFESSIONAL
SERVICES. IF PROFESSIONAL ASSISTANCE IS REQUIRED, THE SERVICES OF A
COMPETENT PROFESSIONAL PERSON SHOULD BE SOUGHT. NEITHER THE
PUBLISHER NOR THE AUTHOR SHALL BE LIABLE FOR DAMAGES ARISING
HEREFROM. THE FACT THAT AN ORGANIZATION OR WEBSITE IS REFERRED TO IN
THIS WORK AS A CITATION AND/OR A POTENTIAL SOURCE OF FURTHER
INFORMATION DOES NOT MEAN THAT THE AUTHOR OR THE PUBLISHER ENDORSES
THE INFORMATION THE ORGANIZATION OR WEBSITE MAY PROVIDE OR
RECOMMENDATIONS IT MAY MAKE. FURTHER, READERS SHOULD BE AWARE THAT
INTERNET WEBSITES LISTED IN THIS WORK MAY HAVE CHANGED OR DISAPPEARED
BETWEEN WHEN THIS WORK WAS WRITTEN AND WHEN IT IS READ.

For general information on our other products and services or to obtain technical support, please contact
our Customer Care Department within the ($=$(%&/&)%$=, outside the U.S. at =$(%(%$$__(/$-$)($, or fax |@##43@#.
Ataraxiainc also publishes its books in a variety of electronic formats. Some content that appears in print
may not be available in electronic books.
Library of Congress Control Number: -!$&$+-+)=(%/
ISBN: !?=)$(%/&-/+*
Manufactured in the Chibchombian World
10 9 8 7 6 5 4 3 2 1
2O/QW/RQ/QU/IN

POLITEXT

Antonio R. Mar Bernat


Antonio Aguado de Cea
Luis Agull Fit
Fernando Martnez Abella
Diego Cobo del Arco

Hormign armado
y pretensado. Ejercicios
Adaptado a la instruccin EHE

EDICIONS UPC

La presente obra fue galardonada en el tercer concurso


"Ajut a l'elaboraci de material docent" convocado por la UPC.

Primera edicin: abril de 1999

Diseo de la cubierta: Manuel Andreu

los autores, 1999


Edicions UPC, 1999
Edicions de la Universitat Politcnica de Catalunya, SL
Jordi Girona Salgado 31, 08034 Barcelona
Tel. 934 016 883 Fax. 934 015 885
Edicions Virtuals: www.edicionsupc.es
e-mail: edupc@sg.upc.es

Produccin:

CBS Impressi digital


Pintor Fortuny 151, 08224 Terrassa (Barcelona)

Depsito legal: B-19994-99


ISBN: 84-8301-302-9

Quedan rigurosamente prohibidas, sin la autorizacin escrita de los titulares del copyright, bajo las sanciones
establecidas en las leyes, la reproduccin total o parcial de esta obra por cualquier medio o procedimiento,
comprendidos la reprografa y el tratamiento informtico y la distribucin de ejemplares de ella mediante alquiler
o prstamo pblicos, as como la exportacin e importacin de ejemplares para su distribucin y venta fuera
del mbito de la Unin Europea.

Prlogo

Prlogo
El hormign armado y el hormign pretensado son dos tcnicas que tradicionalmente han sido
objeto de un tratamiento separado, en su enfoque docente, en la normativa e incluso en la prctica
profesional (el pretensado se consideraba propio de especialistas), fundamentalmente por razones
histricas. En efecto, el hormign armado, en su concepcin actual, naci a finales del siglo XIX,
mientras que el hormign pretensado no fue una realidad en la prctica hasta mediados de este siglo.
E incluso, desde su nacimiento, el hormign pretensado fue entendido como un material nuevo y
contrapuesto al hormign armado, al considerarse, errneamente, que careca de fisuracin, dado el
estado tensional previo creado artificialmente por las armaduras activas.
Sin embargo, este concepto ha evolucionado hasta el punto de considerar en la actualidad ambas
tcnicas armado y pretensado-, como dos extremos de un mismo material: el hormign estructural.
Y ello se refleja en la fusin de las asociaciones internacionales CEB y FIP en la Fderation
Internationale du Bton (FIB), en el tratamiento docente conjunto de que es objeto en algunas
escuelas tcnicas de ingeniera (entre ellas, la de Barcelona desde 1979), as como en la normativa
vigente, con la publicacin de textos unificados tanto a escala internacional (Cdigo Modelo CEBFIP 1990, Eurocdigo EC-2) como nacional (Instruccin de Hormign Estructural, EHE 1998).
Por otra parte, esta evolucin ha ido acompaada de la aparicin y el desarrollo de nuevos
materiales, mtodos de clculo y procedimientos constructivos, y la consolidacin y generalizacin
de viejos conceptos, como los mtodos de bielas y tirantes, que plantean nuevas herramientas de
diseo y posibilidades constructivas.
Dentro de este marco tecnolgico, el presente libro tiene un doble objetivo: por una parte, pretende
constituir un elemento didctico de apoyo a la docencia de las asignaturas relacionadas con las
estructuras de hormign y, por otro, ser una referencia que ayude a proyectar este tipo de
estructuras en la prctica profesional, dado que sigue los principios y las reglas establecidos en la
Instruccin de Hormign Estructural EHE. Para ello, ha sabido conjugar, tanto en el enunciado
como en la resolucin de los ejercicios, la simplicidad que requiere un planteamiento pedaggico,
con el realismo que requiere un libro orientado no slo a estudiantes universitarios sino tambin a
profesionales del proyecto y la construccin de estructuras.
El libro recoge algunos de los ejercicios realizados en las clases de Hormign de las titulaciones de
Ingeniera de Caminos, Ingeniera Tcnica de Obras Pblicas e Ingeniera Geolgica de las escuelas
tcnicas superiores de ingenieros de caminos de Barcelona y de La Corua, y otros desarrollados
expresamente para este libro. Si bien todos los enunciados son nuevos en algn aspecto, algunos
ejercicios tienen su origen en la coleccin de problemas elaborada por el conjunto de profesores de
Hormign de la ETSECCPB hace dos dcadas, entre los que se encontraban, adems de los actuales
autores, los profesores Juan Murcia, Enrique Mirambell y Pere Roca, y a quienes queremos
expresar nuestro agradecimiento por su aportacin en aquel momento.

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

El libro se ha dividido en tres grandes bloques: anlisis estructural, estados lmite y elementos
estructurales. En el primero se tratan aspectos relativos a las bases de clculo, tales como acciones,
seguridad, efectos estructurales del pretensado, anlisis seccional o anlisis en el tiempo. En el
segundo se abordan problemas de dimensionamiento y/o comprobacin de secciones o elementos
frente a los estados lmite ltimos (flexin, cortante, torsin, adherencia, anclaje, pandeo) o de
servicio

(fisuracin

deformabilidad).

En

el

tercero

se

estudia

el

proyecto

de

elementos

estructurales completos, como vigas, pilares, mnsulas cortas, placas, vigas de gran canto o zonas
de anclaje. Obviamente se plantean indistintamente elementos de hormign armado o pretensado.
Asimismo, con el afn de aportar soluciones prcticas, se plantean dos ejercicios finales en los que
se hace especial hincapi en la racionalizacin del armado y se proporcionan soluciones con barras
corrugadas y con mallas electrosoldadas. En ambos casos se agradece la colaboracin de Jaume
Grau, ingeniero de Caminos de la empresa CELSA, quien gustosamente ha participado en la
solucin de los mismos.
Asimismo los autores desean expresar su agradecimiento a todas las personas que, de una manera u
otra, han hecho posible la aparicin de este libro: a Vicente Peas, ingeniero de Caminos, cuya
tesina de especialidad fue el germen de este libro y que colabor como becario resolviendo
numerosos

ejercicios;

Carolina

Guerrero,

becaria

del

Departamento

de

Ingeniera

de

la

Construccin de la UPC, que ha realizado una paciente revisin de las soluciones de todos los
ejercicios, procurando de que stos salieran a la luz sin erratas; a Rosa Morera, tambin becaria del
Departamento, que ha colaborado en la revisin y edicin final del texto; a los profesores Cristina
Vzquez y Manuel F. Herrador y a los becarios Alberto Veiras y Javier Anchelergues, todos ellos
integrantes del Grupo de Construccin de la Escuela de Caminos de La Corua, que han colaborado
en la realizacin de algunos problemas; y, sobre todo, a Elena Sau, secretaria del grupo de
hormign, cuya dedicacin y cario en la edicin de este libro sobrepasan lo exigible a cualquier
profesional y slo pueden entenderse cuando se la conoce personalmente. A todos ellos, muchas
gracias.
Finalmente, los autores desean agradecer a Edicions UPC po la ayuda prestada en todo momento
para resolver los problemas de edicin que han ido surgiendo, y a la UPC, que concedi un premio
al proyecto de libro en 1995, por su paciente espera a que este proyecto se hiciera realidad, lo cual
slo ha sido posible tras conocer la versin definitiva de la Instruccin EHE.

Barcelona, marzo de 1999

Los autores, 1998; Edicions UPC, 1998.

ndice

ndice

BLOQUE I Anlisis estructural


Acciones
I-1 Obtencin de leyes de esfuerzo en una viga isosttica .....................................

15

I-2 Obtencin de leyes de esfuerzos en un pescante ............................................

31

I-3 Obtencin de leyes de esfuerzos en un prtico isosttico ..................................

41

I-4 Obtencin de leyes de esfuerzos en una viga continua de hormign armado ...........

63

Materiales
I-5 Deformaciones del hormign. Estudio a nivel probeta ....................................

69

I-6 Problema de relajacin y fluencia .............................................................

75

Anlisis estructural
I-7 Prdidas instantneas y diferidas en una viga con armaduras postesas ..................

89

I-8 Prdidas instantneas y diferidas en una viga con armaduras pretesas ..................

95

I-9 Cargas y esfuerzos debidos al pretensado en estructuras isostticas .....................

103

I-10 Hiperestticos de pretensado. Trazado concordante. Viga continua ....................

109

I-11 Esfuerzos de pretensado en un prtico biempotrado ......................................

115

I-12 Anlisis en el tiempo. Construccin evolutiva .............................................

123

Anlisis seccional
I-13 Diagrama M-C de secciones de hormign armado ........................................

135

I-14 Diagrama M-C de secciones de hormign pretensado con adherencia .................

145

I-15 Seccin sometida a traccin pura. Armaduras pretesas ..................................

155

I-16 Efectos trmicos a nivel seccin .............................................................

161

Curado
I-17 Curado de estructuras de hormign .........................................................

169

BLOQUE II Estados lmites ltimos


E.L.U. de agotamiento por solicitaciones normales
II-1 Influencia de las cuantas y el axil en el comportamiento en E.L.U.
de secciones rectangulares ..........................................................................

173

II-2 Dimensionamiento y comprobacin de secciones rectangulares en flexin simple ...

179

Los autores, 1998; Edicions UPC, 1998.

10

Hormign armado y pretensado. Ejercicios

II-3 Dimensionamiento y comprobacin de secciones rectangulares


en flexocompresin recta ............................................................................

185

II-4 Dimensionamiento y comprobacin de secciones mediante diagramas


de interaccin en flexin recta y esviada .........................................................

191

II-5 Comprobacin del E.L.U de flexocompresin de secciones pretensadas


con armadura adherente y no adherente ..........................................................

199

E.L.U. de agotamiento por solicitaciones tangenciales


II-6 Esfuerzo cortante en vigas de hormign armado y pretensado
con armaduras pretesas ..............................................................................

203

II-7 Cortante en vigas de hormign pretensado con armaduras postesas ....................

215

II-8 Torsin en una viga de hormign armado ..................................................

223

II-9 Torsin en una viga de hormign armado embrochalada .................................

231

II-10 Torsin en una viga de hormign pretensado .............................................

243

E.L.U. a cortante-friccin
II-11 Anlisis de secciones de piezas compuestas por varios hormigones.
Cortante friccin .....................................................................................

253

E.L.U. adherencia y anclaje


II-12 Anclaje de armaduras postesas ..............................................................

257

II-13 Anclaje por adherencia de armaduras pretesas ............................................

261

E.L.U. pandeo
II-14 Dimensionamiento de soportes esbeltos aislados: mtodos simplificados
y columna modelo ....................................................................................

265

II-15 Comprobacin de soportes esbeltos en prticos. Mtodo simplificado ...............

273

E.L.U. servicio
II-16 Fisuracin y deformabilidad en vigas de hormign armado ............................

279

II-17 Fisuracin de una viga de hormign pretensado ..........................................

287

II-18 Deformabilidad de forjados pretensados ...................................................

297

BLOQUE III Elementos estructurales


III-1 Pasarela peatonal postensada .................................................................

305

III-2 Viga sometida a flexin y cortante. Dimensionamiento completo de armaduras ....

323

III-3 Dimensionamiento de un pescante ..........................................................

329

III-4 Zapata y encepado para pescante ............................................................

343

III-5 Viga de puente pretensado para trabajar junto a losa de compresin ..................

361

III-6 Tirante de hormign pretensado .............................................................

371

III-7 Viga de gran canto .............................................................................

379

Los autores, 1998; Edicions UPC, 1998.

11

ndice

III-8 Mnsula corta para puente-gra .............................................................

383

III-9 Punzonamiento de una placa en un pilar ...................................................

387

III-10 Punzonamiento de placas bajo cargas concentradas .....................................

391

III-11 Racionalizacin del armado I ...............................................................

397

III-12 Racionalizacin del armado II ..............................................................

407

Los autores, 1998; Edicions UPC, 1998.

Anlisis estructural

13

BLOQUE I Anlisis estructural

Los autores, 1998; Edicions UPC, 1998.

15

Acciones

Ejercicio I-1 Obtencin de leyes de esfuerzo en una viga isosttica


Una viga de hormign armado de 13 m de longitud total y seccin rectangular de 1.0 x 0.30 m, se
encuentra simplemente apoyada en dos puntos como se muestra en la figura.

Las acciones que pueden actuar sobre la viga son:


a)

Un descenso del apoyo B de 2 cm.

b)

Una carga uniformemente repartida de 10 kN/m que puede extenderse de cualquier forma.

c)

Una carga puntual mvil de 80 kN.

Se considerar un nivel de control intenso. Se considerar que las dos acciones variables tienen el
mismo origen.

Se pide:
Utilizando los criterios de combinacin de la EHE98:
1.
2.

comprobar el equilibrio de la estructura,


determinar las leyes de solicitaciones de clculo con las que debe dimensionarse la estructura
frente a E.L.U.

Solucin

1 Comprobacin del estado lm ite de equilibrio


Acciones:

- peso propio, p = 0.30 m1.0 m25 kN/m = 7.5 kN/m


- carga variable uniforme, q = 10 kN/m
- carga puntual mvil, Q = 80 kN
- el descenso de apoyo no origina esfuerzos al tratarse de una estructura isosttica.

Los autores, 1998; Edicions UPC, 1998.

16

Hormign armado y pretensado. Ejercicios

Configuracin de cargas:

Adoptando la hiptesis de que el esquema esttico corresponde a la situacin de construccin:

gG* = 0.95
gG** = 1.10
En el caso de que la hiptesis sea que el esquema esttico corresponde a la situacin de servicio,
sera

gG* = 0.9 y gG** = 1.10.


g

En consecuencia, tomando Q = 1.50 para las acciones variables, se tiene:

120 kN
15 kN/m

7.13 kN/m

8.25 kN/m

- Planteamos los momentos volcador y estabilizador respecto al punto B.


Momento volcador

Mv = 8.25 kN/m

32
2

m + 15 kN/m

32
2

m + 120 kN3 m = 464.36 kNm

Momento estabilizador

ME = 7.13 kN/m

10 2
2

m = 356.5 kNm

Notemos que al considerar las dos sobrecargas variables como correspondientes al mismo tipo no
tenemos reduccin en la combinacin por los factores

Y.

ME = 356.5 kNm < Mv = 464.63 kNm


No se cumple el estado lmite ltimo de equilibrio.
- Otra forma de proceder es calcular la reaccin en el apoyo A. Considerando esta reaccin positiva

(RA ), y tomando momentos respecto a B, se tiene:

Los autores, 1998; Edicions UPC, 1998.

17

Acciones

RA10 m - 7.13 kN/m

10 2
2

m + 8.25 kN/m

32
2

m + 15 kN/m

32
2

+ 120 kN3 m = 0
RA10 + 108.13 = 0
RA = -10.81 kN
Ello conduce, en ambos casos, a tener que anclar el apoyo A.

2 Leyes de las solicitaciones de clculo


- Cargas permanentes:
3

peso propio, p = 0.30 m1.0 m25 kN/m = 7.5 kN/m


*

p =
**

gGp = 1.357.5 kN/m = 10.13 kN/m

= 7.5 kN/m

- Cargas variables:

gGq = 1.5 10 kN/m =


gGQ = 1.580 kN = 120 kN
*

uniformemente repartida, q =
*

puntual mvil, Q =

15 kN/m

Criterios para las expresiones analticas


tramo AB (frontales)
0

x 10 m

tramo CB (dorsales)
0

x3m

2.1 Leyes de momentos flectores


- Cargas permanentes:
*
p =10.13 kN/m

-45.63 m.kN

104.96 m.kN

Los autores, 1998; Edicions UPC, 1998.

m +

18

Hormign armado y pretensado. Ejercicios

Ley I
Tramo AB: 0

x 10 m

M x = 5.07x(9.1 - x)
I

x = 0

M = 0

x = 4.55 m

M max = 104.96 kNm

x = 9.10 m

M = 0

x = 10 m

M = -45.63 kNm

Tramo BC: 0
I

I
I
I

x3m
2

M x = -5.07x

x = 0

M = 0

x = 3 m

M = -45.63 kNm

p** = 7.5 kN/m

-33.75 m.kN

77.63 m.kN

Ley II
Tramo AB: 0

x 10 m

II

M x = 3.75x(9.1-x)
II

x = 0

x = 4.55 m

M max = 77.63 kNm

II
II

= 0

x = 9.10 m

x = 10 m

M = -33.75 kNm

Tramo BC: 0
II

= 0

x3m
2

M x = -3.38x

II

x = 0

= 0

x = 3 m

= -30.42 kNm

II

Carga variable uniformemente repartida q* = 15 kN/m

Los autores, 1998; Edicions UPC, 1998.

19

Acciones

Momentos flectores positivos

Ley III
Tramo AB: 0

x 10 m

III

M x = 75x 7.5x

III

x = 0

x = 5 m

M max = 187.5 kNm

x = 10 m

III
III

= 0
= 0

Momentos flectores negativos

Ley IV
Tramo AB: 0

x 10

IV

M x = -6.75x

IV

x = 0

= 0

x = 10 m

= -67.50 kNm

Tramo CB: 0
IV

IV

x3
2

M x = -7.5x

IV

x = 0

= 0

x = 3 m

= -67.50 kNm

IV

Carga puntual mvil Q = 120 kN

Momentos flectores positivos

Los autores, 1998; Edicions UPC, 1998.

20

Hormign armado y pretensado. Ejercicios

Ley V
Tramo AB:

x 10 m

M x = 120 x 12 x
V

X = 0

X = 5 m

M mx = 300 m.kN

X = 10 m

= 0

= 0

Momentos flectores negativos

Ley VI
Tramo AB:

x 10 m

VI

M x = 36 x
VI

X = 0

X = 10 m

Tramo CB:

VI

= 0
= -360 m.kN

x3m

VI

M x = -120 x
VI

X = 0

X = 3 m

VI

= 0
= -360 m.kN

Composicin de momentos flectores positivos


Tramo biapoyado (AB)

x 9.10 m

I + III + V
2

Md (x) = 5.07x (9.10-x) + 75x 7.5x + 120x 12x


2

= 241.14x 24.57x
X = 0

Md = 0

Los autores, 1998; Edicions UPC, 1998.

21

Acciones

X = 4.91 m

Mdmx = 591.66 m.kN

X = 9.10 m

Md = 159.73 m.kN

9.10 m

x 10 m

II + III + V
2

Md (x) = 3.75x (9.1-x) + 75x 7.5x + 120x 12x


2

= 229.13x 23.25x
X = 9.10 m

Md = 159.71 m.kN

X = 9.86 m

Md = 0

Composicin de momentos flectores negativos


Tramo biapoyado (AB)

x 9.10 m

II + IV + VI

Md (x) = 3.75x (9.1-x) 6.75x 36x


2

= -8.63x 3.75x
X = 0

Md = 0

X = 9.10 m

Md = -389.03 m.kN

9.10 m

x 10 m

I + IV + VI

Md (x) = 5.07x (9.10-x) - 6.75x 36x


2

= 3.39x 5.07x
X = 9.10 m

Md = -389 m.kN

X = 10 m

Md = -473.1 m.kN

Tramo voladizo (CB)

x 3 m I + IV + VI
2

Md (x) = -5.07x 7.5x 120x


2

= -12.57x 120x
X = 0

Md = 0

X = 3 m

Md = - 473.13 m.kN

Los autores, 1998; Edicions UPC, 1998.

22

Hormign armado y pretensado. Ejercicios

389 m.kN

473.1 m.kN

9.86 m
9.10 m
4.91 m

159.7 m.kN
591.7 m.kN

2.2 Leyes de esfuerzos cortantes


- Cargas permanentes
*
p =10.13 kN/m

-55.21 kN
4.55 m

30.39 kN

46.09kN

Ley I
Tramo AB:

x 10 m

V x = 46.09 10.13x
X = 0

V = 46.09 kN
I

V = 0

X = 4.55 m
X = 10 m

V = -55.21 kN

Los autores, 1998; Edicions UPC, 1998.

23

Acciones

Tramo CB:

x3m

V x = 10.13 x
I

X = 0

V = 0

X = 3 m

V = 30.39 kN

p** = 7.5 kN/m

-40.87 kN

22.5 kN

34.13 kN

Ley II
Tramo AB:

x 10 m

II

V x = 34.13 7.5x
X = 0

II

= 34.13 kN
II

X = 4.55 m

= 0

II

X = 10 m

V = -40.87 kN

Tramo CB:

x3m

II

V x = 7.5 x
II

X = 0

X = 3 m

V = 22.5 kN

= 0

II

Carga variable uniformemente repartida q* = 15 kN/m


Actuando en el tramo biapoyado: 0

x 10

Los autores, 1998; Edicions UPC, 1998.

24

Hormign armado y pretensado. Ejercicios

Vx

= -q

2l

= -0.75x 2

X = 0

V = 0

X = 10 m

V = -75 kN

Vx

(l - x )2
2l

( - x )2

0.75 10

X = 0

V = 75 kN

X = 10 m

V= 0

Actuando en el voladizo:
Tramo AB:

Vx

=-

q l

2l

x 10

= -6.75kN

Los autores, 1998; Edicions UPC, 1998.

25

Acciones

Tramo CB:
Vx

x3

= q x = 15x

X = 0

V = 0

X = 3

V = 45 kN

Agrupando en cortantes positivos (ley III) y cortantes negativos (ley IV):

Ley III
Tramo AB:

III

x 10

= 0.75(10 - x )2
III

X = 0

X = 10

= 0

Tramo CB:

x3

III

III

= 75 kN

= 15 x
III

X = 0

X = 3

Tramo AB:

III

= 0
= 45 kN

Ley IV

IV

x 10

= -6.75 - 0.75x 2

Los autores, 1998; Edicions UPC, 1998.

26

Hormign armado y pretensado. Ejercicios

IV

X = 0

X = 10

IV

Carga puntual mvil

= -6.75 kN
= -81.75 kN

Q* = 120 kN

Actuando en el tramo biapoyado (AB):

Tramo AB:

x 10

-
10

Vx = 120 1

X = 0

V = 120 kN

X = 10

V= 0

Vx = 12x
X = 0

V = 0

X = 10

V = -120 kN

Actuando en el voladizo (CB):

Tramo AB:

x 10

Los autores, 1998; Edicions UPC, 1998.

27

Acciones

Vx

=-

Q * la
l

= -36kN

Tramo CD:

x3

Vx = Q* =120 kN
Agrupando en cortantes positivos (ley V) y cortantes negativos (ley VI):

Ley V
Tramo AB:

x 10

-
10

V x = 120 1

= 120 kN

X = 0

X = 10

V = 0

Tramo CB:

x3

V x = 120 kN
X = 0

V = 120 kN

X = 10

V= 0

Tramo AB:

Ley VI

x3

x 10
VI

V x = -36 kN

Los autores, 1998; Edicions UPC, 1998.

28

Hormign armado y pretensado. Ejercicios

x 10

VI

V x = - 12x

Composicin de cortantes positivos


Tramo biapoyado (AB)
0

x 4.55 m

I + III + V
x

-
10

Vd (x) = 46.09 - 10.13x + 0.7 5(10-x) + 120 1


2

= 241.09 37.13x + 0.75x


X = 0

Vd = 241.09 kN

X = 4.55 m

Vd = 87.68 kN

4.55 m

x 10 m

II + III + V

-
10

Vd (x) = 34.13 7.5x + 0.75(10-x) + 120 1


2

= 229.13 34.5x + 0.75x


X = 4.55 m

Vd = 87.68 kN

X = 8.05 m

Vd = 0

Tramo voladizo (CB)


0

x3m

I + III + V

Vd (x) = 10.13x + 15x + 120


= 25.13x + 120
X = 0

Vd = 120 kN

X = 3 m

Vd = 195.39 kN

Composicin de cortantes negativos


Tramo biapoyado (AB)
0

x 4.55 m

x3m

II + IV + VI
2

Vd (x) = 34.13 - 7.5x - 6.75 - 0.75x - 36 =


2

= -8.62 7.5x 0.75x

Los autores, 1998; Edicions UPC, 1998.

29

Acciones

X = 0

Vd = - 8.62 kN

X = 3 m

Vd = -37.87 kN

3 m

x 4.55 m

Vd (x) = 34.13 - 7.5x - 6.75 - 0.75x 12x


2

= 27.38 19.5x 0.75x


X = 3 m

Vd = - 37.87 kN

X = 4.55 m

Vd = -76.87 kN

4.55 m

x 10 m

I + IV + VI
2

Vd (x) = 46.09 10.13x 6.75 0.75x 12x


2

= 39.34 22.13x 0.75x


X = 4.55 m

Vd = -76.88 kN

X = 10 m

Vd = - 256.96 kN

257

76.9 kN

8.05 m

87.7 kN
195.4 kN
241 kN

Los autores, 1998; Edicions UPC, 1998.

31

Acciones

Ejercicio I-2 Obtencin de leyes de esfuerzos en un pescante

Considrese el pescante de hormign armado cuyas dimensiones se indican en la figura adjunta.


Dicha estructura se encuentra a la intemperie en un ambiente exterior normal.

La estructura est sometida a las siguientes acciones:


-peso propio: 8 kN/ml,
-sobrecarga uniforme permanente en el dintel de 22 kN/ml,
-sobrecarga de uso: carga puntual mvil de 100 kN que puede actuar nicamente en el
tramo del dintel,
-viento: carga puntual horizontal de 50 KN,
-nieve: sobrecarga uniforme de 10 kN/ml.
Se consideran los siguientes materiales:
-hormign HA-30/P/12/IIb f = 30 MPa,
-acero B-500 S f = 500 MPa.
Asimismo, se considera un nivel de control intenso.
(AC)

BC

ck

yk

Se pide:

1. Obtener las leyes de esfuerzos de clculo con los que se debe dimensionar la estructura frente a
estados lmite ltimos, utilizando el criterio simplificado para estructuras de edificacin de la
instruccin EHE.
Solucin
1.1

Coeficientes de seguridad pa r a acciones

A la vista de las acciones que se tienen en cuenta, se considera la situacin persistente o transitoria a
la hora de combinar las acciones.

Los autores, 1998; Edicions UPC, 1998.

32

Hormign armado y pretensado. Ejercicios

Dado que el nivel de control es intenso, los coeficientes parciales de seguridad son los que siguen:
Tipo de accin
Efecto
Favorable
Desfavorable
Permanente
1
1.35
Variable
0
1.50
1.2

Solicitaciones de clculo

1.2.1

Momentos flectores

Cargas permanentes en el dintel: peso propio y carga permanente


G = 8+22 = 30 kN/ml

80 kNm

13.5 kNm

75 kNm

Los autores, 1998; Edicions UPC, 1998.

33

Acciones

Sobrecarga de uso mvil


Q = 100 kN

Viento
H = 50 kN

Nieve
q = 10 kN/ml

Los autores, 1998; Edicions UPC, 1998.

34

Hormign armado y pretensado. Ejercicios

Para situaciones persistentes o transitorias, EHE admite cuando se trata de estructuras de edificacin
sometidas a dos o ms acciones variables afectar los coeficientes de seguridad de stas por el factor
0.9. Procediendo de este modo obtenemos:
Envolvente de momentos flectores

225 kNm

1.2.2

Esfuerzo cortante

Cargas permanentes en el dintel: peso propio y carga permanente


G = 8+22 = 30 kN/ml

60 kN

90 kN

Los autores, 1998; Edicions UPC, 1998.

35

Acciones

Sobrecarga de uso mvil


Q = 100 kN

Viento
H = 50 kN

Nieve
q = 10 kN/ml

Los autores, 1998; Edicions UPC, 1998.

36

Hormign armado y pretensado. Ejercicios

Envolvente de esfuerzos cortantes

1.2.3

Axiles

Cargas permanentes en el dintel: peso propio y carga permanente


G = 8+22 = 30 kN/ml

150 kN

Los autores, 1998; Edicions UPC, 1998.

37

Acciones

135.5 kNm
60 kNm

81 kNm

MI

75 kNm

101.25 kNm

Peso propio del pilar


G = 8kN/ml
p

32 kN

43.2 kN

Sobrecarga de uso mvil


Q = 100 kN

Los autores, 1998; Edicions UPC, 1998.

182.25 kNm

MII

38

Hormign armado y pretensado. Ejercicios

450 kNm

450 kNm

MV

Viento
H = 50 kN
M VI

M VII

300kNm

300 kNm

Nieve
q = 10 kN/ml
30 kNm

1.510(2+3)=75 kN

67.5 kNm

MVIII

37.5kNm

Los autores, 1998; Edicions UPC, 1998.

39

Acciones

Envolvente de axiles y momentos flectores concomitantes.


VI

M II+M VIII

VII

648 kNm
111 kNm
M II+ 0.9 (M V+M VII1)
510 kNm

M II+(M V+M VII+M VII) 0.9


M I +M VII

810 kNm

225 kNm

Los autores, 1998; Edicions UPC, 1998.

41

Acciones

Ejercicio I-3 Obtencin de leyes de esfuerzos en un prtico isosttico


Sea la estructura de una cubierta (vase la figura adjunta) situada en la costa de A Corua en
situacin expuesta.

l=6 m
50 cm

30 cm

h=5 m
40 cm

Detalle nudo pilar-dintel

Sobre ella pueden actuar las siguientes acciones:


a)

Una carga permanente (vertical y descendente) formada por una carga repartida sobre todo el
dintel de valor 7.5 kN/m.

b)

Una carga variable puntual (vertical y descendente) que acta en el dintel, de valor 50 kN, y

Y0=0.7; Y1=0.5; Y2=0.3).

cuya posicin es libre a lo largo de la longitud del dintel (


c)

Una

carga

de

viento

horizontal

en

el

plano

del

prtico

Y0 =

indistintamente, de derecha a izquierda o viceversa (

0.6;

cuya

direccin

puede

Y1=0.5; Y2=0.25).

ser,

De cara a

la carga de viento debe considerarse un ancho (en el plano perpendicular al prtico) de 6 m. El


valor de la carga de viento puede calcularse de acuerdo a la norma NBE-AE-88, segn los
grficos adjuntos.

Se pide:
Hallar las leyes de solicitaciones de clculo de los esfuerzos axil y momento flector en ELU, para la
situacin persistente o transitoria.
Nota: Considrense los coeficientes de seguridad correspondientes a un control intenso. Se
considerar

g = 0.9 como coeficiente de seguridad para las acciones permanentes favorables.

Los autores, 1998; Edicions UPC, 1998.

42

Hormign armado y pretensado. Ejercicios

Solucin
1 Valor de

gf

. Control intenso

ELU

ELS

Perm. o Transit.

Peso Propio (PP) G

g
g
g
g
g
G

C. Permanente (CP) G

C. Var. Puntual(CVP) Q

C. Var. Viento Izq.(CWI) Q

C. Var. Viento Izq.(CWI) Q

Accidental

Fav.

Desfav.

Fav.

Desfav.

Fav.

Desfav.

0.9

1.35

0.9

1.35

1.5

1.5

1.5

2 Criterio de signos

Esfuerzo axil

Pilar izquierdo (PI)

Pilar derecho (PD)

Dintel (D)

PI

PD

Positivo (traccin)

Negativo(con presin)

Momento flector

Positivo

Negativo

Coordenadas:
x

Los autores, 1998; Edicions UPC, 1998.

43

Acciones

3 Acciones y leyes parciales


3.75 kN/m

3.1 Peso propio (pp)

Pilares:
25 kN m

0.4m 0.3m = 3 kN

m
3 kN/m

Dinteles:
25 kN m

0.5m 0.3m = 3.75 kN

3 kN/m

-11.25 kN

Esfuerzos:

-11.25 kN

Npp
P.I.: N(x)=-26.25+3x
D: N(x)=0
P.D.: N(x)=-26.25+3x
-26.25 kN

-26.25 kN

Mpp
P.I.: M(x)=0

D: M(x)=-1.875x +11.25x

16.875 mkN

P.D.: M(x)=0

3.2 Carga permanente (cp)


7.5 kN/m

Los autores, 1998; Edicions UPC, 1998.

44

Hormign armado y pretensado. Ejercicios

Esfuerzos:
Ncp
P.I.: N(x)=-22.5
D: N(x)=0
P.D.: N(x)=-22.5

Mcp
P.I.: M(x)=0
D: M( x )

p l

= - x2 +

x = -3.75x 2 + 22.5x

33.75 mkN

P.D.: M(x)=0

3.3 Carga variable puntual en di ntel (cvp)

Q y

RB

RA

=Q-

Q y
6

Q
6 (6 - y ) x x y
M( x ) =
Q y (6 - x ) x y
6

En el dintel,

y la envolvente para y=x es: M( x )

Q
6

x (6 - x ) .

RA

RB

"y:

Esfuerzos
Ncvp

P.I.: N( x )

=-

Q
6

Q =50 kN
(6 - y )
8.333 (6 - y )

D: N(x) = 0
P.D.: N ( x )

=-

Q
6

Q = 50 kN
y
-8.333 y

Los autores, 1998; Edicions UPC, 1998.

-22.5 kN

-22.5 kN

45

Acciones

Mcvp
P.I.: M(x)=0

Q
Q = 50 kN
6 (6 - y ) x x y 8.333 (6 - y ) x
D: M( x ) =
Q = 50 kN
Q y (6 - y ) x y
8.333 (6 - x ) y
6
P.D.: M(x)=0
Envolvente de esfuerzos mximos:
Axiles:
P.I.: N (x) = -Q (y=0)
D: N(x) = 0
P.D. N(x) = -Q (y=6)
-50 kN

-50 kN

Momentos:
P.I.: M(x)=0
D: M( x )

Q
6

x (6 - x ) = 50 x - 8.333x 2

75 m .kN

P.D.: M(x)=0

3.4 Carga de viento por la izquie rda (cwi)


La estructura se encuentra en zona elica Y (A Corua) y en la situacin topogrfica expuesta. Si se
2

toma una altura de 6 m sobre el nivel del suelo se obtiene una carga de viento p de 82 kp/m . Por la
izquierda actuar una carga de 2p/3 y por la derecha una de p/3. Sobre la cubierta, con un ngulo
2

de 0, se produce una succin m de valor 31 kp/m considerando una edificacin sin huecos. Las
cargas totales se obtienen para un ancho de 6 m.

Los autores, 1998; Edicions UPC, 1998.

46

Hormign armado y pretensado. Ejercicios

1.86 kN/m

M = 31 kp/m = 0.31 kN/m


2

P=82kp/m =0.82 kN/m


Ancho = 6 m, luego

2p/3 = 3.28 kN/m y p/3 = 1.64 kN/m

3.28 kN + 1.64 kN 5m = 24.6kN

m
m

H = 24.6kN
R B = 4.67kN
R A = 15.83kN

H
RA

Los autores, 1998; Edicions UPC, 1998.

RB

47

Acciones

Esfuerzos en pilar izquierdo:

3.28 kN/m

24.6 kN
15.83 kN

15.83 kN

N( x )

RA

M( x )

M( 5 )

= 82 m kN

82 mkN

= 15.83 kN

x - 3.28

24.6

x - 1.64 x 2

Esfuerzos en dintel:

1.86 kN/m

82 mkN

8.2 kN

15.83 kN

N( x )

= 8.2kN

8.2 kN

= 82 + 0.93 x 2 - 15.83 x
M( 0 ) = 82 m kN
M(3) = 42.88 m kN
M(6 ) = 20.5 m kN
M( x )

20.5 mkN
82 mkN

Los autores, 1998; Edicions UPC, 1998.

48

Hormign armado y pretensado. Ejercicios

Esfuerzos en pilar derecho:

1.64 kN/m

4.67 kN
20.5 mkN

4.67 kN

N( x )

= -4.67kN

M( x )

= 1.64

= 0.82 x 2

=0
M( 5 ) = 20.5 m kN
M( 0 )

Resultar, por tanto:


8.2 kN
82 mkN

20.5 mkN

20.5 mkN

82 mkN

4.67 kN

15.83 kN

3.5 Carga de viento por la derec ha (cwd)


1.86kN/m

H=24.6 kN
RA=4.67 kN

1.64 kN/m

3.28 kN/m

RB=15.83 kN

H
RA

Los autores, 1998; Edicions UPC, 1998.

RB

49

Acciones

Esfuerzos en pilar izquierdo:

24.6 kN
4.67 kN

4.67 kN

N( x )

102.5 mkN

= -4.67kN

= 0.82 x 2 - 24.6 x
M( 0 ) = 0
M( 5 ) = -102.5 m kN

M( x )

Esfuerzos en dintel:
1.86 kN/m

x
102.5 mkN

16.4 kN

4.67 kN

N( x )

= -16.4kN

= -102.5 + 4.67 x + 0.93 x 2


M( 0 ) = -102.5 m kN
M( 3) = -82.12 m kN
M( 6 ) = -41m kN

102.5 mkN

M( x )

16.4 kN

Esfuerzos en pilar derecho:

3.28 kN/m

15.83 kN

Los autores, 1998; Edicions UPC, 1998.

41 mkN

50

Hormign armado y pretensado. Ejercicios

41 mkN

15.83 kN

N( x )

= 15.83kN

M( x )

= -3.28

= -1.64 x 2

=0
M( 5 ) = -41m kN
M( 0 )

Por lo tanto:
16.4 kN

102.5 mkN

41 mkN

4.67 kN

15.83 kN

4 Combinacin de acciones
La combinacin en ELU para situaciones persistentes o transitorias se debe calcular, segn la
instruccin, como sigue:

Gj G kj

j 1

g
j 1

G* j

*
G kj

+ g p Pk + g Q,1 Q k,1 +

> g

Q,i y 0,i Q k ,i

i 1

En este caso,
*

G kj=0
Pk=0
*

G kj: acciones permanentes (pp y cp)


Qk,1: accin variable determinante
Qki: accin variable concomitante
La combinacin debe hacerse variando la accin variable determinante para obtener la psima
situacin de la estructura en cada seccin. En este caso, por tanto, la accin variable determinante
debe ser:
Accin variable determinante

Accin variable concomitante

Qcp

Qcwi o Qcwd

Qcwi

Qcp

Qcwd

Qcp

Los autores, 1998; Edicions UPC, 1998.

51

Acciones

4.1 Combinacin de envolventes


Considerando concomitantes los esfuerzos de las distintas envolventes, se expone el clculo de las
distintas combinaciones que surgiran a partir de las envolventes y considerando los esfuerzos
mximos por separado para E.L.U. en situacin permanente o transitoria:
a) Dintel
a.1) Q1=cvp
Momentos positivos:
+

= 1.35 Mpp + 1.35 Mcp + 1.5 Mcvp + 1.5 0.6 Mcwi , de donde:
2

M(x) = 1.35(-1.875x +11.25x)+1.35(-3.75x +22.5x)+


2

+1.5(50x-8.333x )+1.50.6(82+0.93x -15.83x)=


2

M(x) = -19.25625x +106.32x+73.8


Momentos negativos:
-

M = 0.9 Mpp + 0.9 Mcp + 1.5 0.6 Mcwd , de donde:


2

M(x) = 0.9(-1.875x +11.25x)+0.9(-3.75x +22.5x)+


2

+1.50.6(-102.5+4.67x+0.93x )=
2

M(x) = -4.23x +37.73x-92.25


Axiles positivos:
+

= 1.5 0.6 Ncwi , de donde:

N(x) = 1.50.68.2 = 7.38


Axiles negativos:
-

N = 1.5 0.6 Ncwd , de donde:


N(x) = 1.50.6(-16.4)= -14.76
a.2) Q1=cwi
Momentos positivos:
+

= 1.35 Mpp + 1.35 Mcp + 1.5 0.7 Mcvp + 1.5 Mcwi , de donde:
2

M(x) = 1.35(-1.875x +11.25x)+1.35(-3.75x +22.5x)+


2

+1.50.7(-8.333x +50x)+1.5(0.93x -15.83x+82)=


2

M(x) = -14.95x +74.32x+123


Momentos negativos ya calculados.

Los autores, 1998; Edicions UPC, 1998.

52

Hormign armado y pretensado. Ejercicios

Axiles positivos:
+

= 1.5 0.6 Ncwi , de donde:

N(x) = 1.58.2 = 12.3


Axiles negativos ya calculados.
a.3) Q1=cwd
Momentos positivos ya calculados.
Momentos negativos:
-

M = 0.9 Mpp + 0.9 Mcp + 1.5 Mcwd , de donde:


2

M(x) = 0.9(-1.875x +11.25x)+0.9(-3.75x +22.5x)+


2

+1.5(-102.5+4.67x+0.93x )=
2

M(x) = -3.67x +37.38x-153.75


Axiles positivos ya calculados.
Axiles negativos:
-

N = 1.5 Ncwd , de0 donde:


N(x) = 1.5(-16.4) = -24.6
b) Pilar izquierdo
b.1) Q1=cvp
Momentos positivos:
+

= 1.5 0.6 Mcwi


2

M(x) = 1.50.6(24.6x-1.64x )=22.14x-1.476x


Momentos negativos:
-

M = 1.5 0.6 Mcwd


2

M(x) = 1.50.6(-24.6x+0.82x ) = -22.14x+0.738x


Axiles positivos:
+

= 0.9 Npp + 0.9 Ncp + 1.5 0.6 Ncwi , de donde:

N(x) = 0.9(3x-26.25)+0.9(-22.5)+1.50.615.83 = -29.63+2.7x


No existen tracciones en el pilar

Los autores, 1998; Edicions UPC, 1998.

53

Acciones

Axiles negativos:
-

N = 1.5 Npp + 1.5 Ncp + 1.5 0.6 Ncwd , de donde:


M(x) = 1.5(3x-26.25)+1.5(-22.5)+1.5(-50)+1.50.6(-4.67) = 4.5x-152.33
b.2) Q1=cwi
Momentos positivos:
+

= 1.5 Mcwi
2

M(x) = 1.5(24.6x-1.64x ) = 36.9x-2.46x


Momento negativo ya calculado.
Axil positivo:
+

= 0.9 Npp + 0.9 Ncp + 1.5 Ncwi , de donde:

N(x) = 0.9(3x-26.25)+0.9(-22.5)+1.5(15.83) = 2.7x-20.13


El pilar est comprimido.
Axil negativo ya calculado.
b.3) Q1=cwd
Momento positivo ya calculado.
Momento negativo:
-

M = 1.5 Mcwd
2

M(x) = 1.5(-24.6x+0.82x ) = -36.9x+1.23x


Axil positivo no existe.
Axil negativo ya calculado.
c) Pilar derecho
c.1) Q1=cvp
Momentos positivos:
+

= 1.5 0.6 Mcwi


2

M(x) = 1.50.6(0.82x ) = 0.738 x

Los autores, 1998; Edicions UPC, 1998.

54

Hormign armado y pretensado. Ejercicios

Momentos negativos:
-

M = 1.5 0.6 Mcwd


2

M(x) = 1.50.6(-1.64x ) = -1.476x


Axiles positivos:
+

= 0.9 Npp + 0.9 Ncp + 1.5 0.6 Ncwd , de donde:

N(x) = 0.9(3x-26.25)+0.9(-22.5)+1.50.6(15.83) = 2.7x-29.63


Axiles negativos:
-

N = 1.5 Npp + 1.5 Ncp + 1.5 0.6 Ncwi , de donde:


N(x) = 1.5(3x-26.25)+1.5(-22.5)+1.5(-50)+1.50.6(-4.67) = 4.5x-151.33
c.2) Q1=cwi
Momentos positivos:
+

= 1.5 Mcwi
2

M(x) = 1.5(0.82x ) = 1.23x

Momentos negativos ya calculados.


Axiles positivos ya calculados.
Axiles negativos ya calculados.
c.3) Q1=cwd
Momentos positivos ya calculados.
Momentos negativos:
-

M = 1.5 Mcwd
2

M(x) = 1.5(-1.64x )= -2.46x


Axiles positivos:
+

= 0.9 Npp + 0.9 Ncp + 1.5 Ncwd , de donde:

N(x) = 0.9(3x-26.25)+0.9(-22.5)+1.5(15.83) = 2.7x-20.13


Compresiones en todos los casos.
Axiles negativos ya calculados.

Los autores, 1998; Edicions UPC, 1998.

55

Acciones

Las envolventes de esfuerzos son las siguientes:

-153.75

30.7

123

-61.59

-153.75

-61.5

219.45

M-

M+

-24.6

12.3
-129.83

-129.83

N-

N+

-152.33

4.2 Combinacin de esfuerzos concomitantes


A continuacin va a suponerse que, como ocurre siempre en realidad, las leyes de envolventes no
proporcionan esfuerzos concomitantes en cada seccin. Con finalidad docente se va a abordar el
problema de la combinacin de esfuerzos concomitantes.
Las leyes de axil y flector, por separado, no tienen excesivo valor, puesto que todos los clculos que
se deriven de ellas debern hacerse para pares de valores (N,M) concomitantes. Esto supone que no
puede trabajarse con las envolventes de cada esfuerzo ya que:
Proporcionan valores mximos de M y N en cada seccin que pueden no ser concomitantes (coste
econmico).
Si se asocian valores mximos de M y N, an sin ser concomitantes, no se tiene garanta de que el
par obtenido (Nmx, Mmx ) sea el ms lesivo para la estructura. Ello queda patente observando, por
ejemplo, un diagrama de interaccin:

Los autores, 1998; Edicions UPC, 1998.

56

Hormign armado y pretensado. Ejercicios

Po sible valo r (N mx ,M mx )
n o co ncom inante

V alo r conco m itante de


(M ,N ) que
resulta m s
perjudicial para
la seccin

El problema debe resolverse estudiando simultneamente la combinacin de M y N concomitantes


en cada seccin, como propone la EHE. Un proceso equivalente al que se va a plantear aqu de
forma manual es el que debe seguirse en los programas de clculo de estructuras.
As se tendr:
Para carga variable determinante Qcp:
Gcp

Gcp

Qcp

Qcwi

Qcwd

COMB.

gy0

gy0

1.35

1.35

1.5

1.35

1.35

1.35

1.35

1.35

0.9

0.9

1.35

1.35

1.35

1.35

1.35

0.9

0.9

1.5

1.5

1.5

1.5

1.5 0.6

1.5 0.6

1.5 0.6

1.5 0.6

1.5 0.6

1.5 0.6

Gpp y Gcp

DESF.

Qcp

DESF.

Qcwi

DESF.

Gpp y Gcp

DESF.

Qcp

DESF.

Qcwd

DESF.

Gpp y Gcp

DESF.

Qcp

DESF.

Qcwi y Qcwd

FAV.

Gpp y Gcp

DESF.

Qcp

FAV.

Qcwi

DESF.

Gpp y Gcp

DESF.

Qcp

FAV.

Qcwd

DESF.

Gpp y Gcp

DESF.

Qcp

FAV.

Qcwi y Qcwd

FAV.

Gpp y Gcp

FAV.

Qcp

DESF.

Qcwi

DESF.

Gpp y Gcp

FAV.

Qcp

DESF.

Los autores, 1998; Edicions UPC, 1998.

57

Acciones

10

11

12

0.9

0.9

0.9

0.9

0.9

0.9

0.9

0.9

1.5

1.5 0.6

1.5 0.6

Qcwd

DESF.

Gpp y Gcp

FAV.

Qcp

DESF.

Qcwi y Qcwd

FAV.

Gpp y Gcp

FAV.

Qcp

FAV.

Qcwi

DESF.

Gpp y Gcp

FAV.

Qcp

FAV.

Qcwd

DESF.

Gpp y Gcp

FAV.

Qcp

FAV.

Qcwi y Qcwd

FAV.

Advirtase que nunca actan simultneamente Qcwi y Qcwd. Cada combinacin proporciona un par (N,
M) en cada seccin de cada elemento de la estructura (pilar derecho, pilar derecho, dintel).
Para carga variable determinante Qcwi:

COMB

Gcp

Gcp

Qcp

Qcwi

Qcwd

gy0

gy0

1.35

1.35

1.5 0.7

1.5

.
1

1.35

1.35

1.35

1.35

1.5

1.5

1.5 0.7

1.35

1.35

1.35

1.35

1.5 0.7

1.35

1.35

0.9

0.9

0.9

0.9

0.9

0.9

1.5 0.7

1.5 0.6

DESF.
DESF.

Qcwi

DESF.

Gpp y Gcp

DESF.

Qcp

FAV .

Qcwi

DESF.

Gpp y Gcp

DESF.

Qcp

DESF.

Qcwd

DESF.

1.5 0.6

REPETIDA
Gpp y Gcp

DESF.

Qcp

DESF.

Qcwi y Qcwd

FAV.

REPETIDA
Gpp y Gcp

FAV.

1.5

Qcp

DESF.

Qcwi

DESF.

Gpp y Gcp

FAV.

Qcp

FAV.

Qcwd

DESF.

Gpp y Gcp

FAV.

Qcp

DESF.

1.5

1.5 0.7

Gpp y Gcp
Qcp

1.5 0.60

Los autores, 1998; Edicions UPC, 1998.

58

Hormign armado y pretensado. Ejercicios

Qcwd
10

0.9

0.9

11

0.9

0.9

1.5 0.7

12

0.9

0.9

DESF.

1.5 0.6

REPETIDA
Gpp y Gcp

FAV.

Qcp

DESF.

Qcwi y Qcwd

FAV.

REPETIDA

Para la carga variable determinante Qcwd:

COMB.
1

Gcp

Gcp

Qcp

Qcwi

Qcwd

gy0

gy0

1.35

1.35

1.35

1.35

1.35

1.35

1.5 0.7

1.5 0.7

1.5 0.7

1.35

1.35

1.35

1.35

1.35

0.9

0.9

0.9

1.5

1.5

1.5 0.6

Gcp y Gcp

DESF.

Qcp

DESF.

Qcwd

DESF.

Gcp y Gcp

DESF.

Qcp

DESF.

Qcwd

DESF.

Gcp y Gcp

DESF.

Qcp

DESF.

Qcwi

DESF.

1.5 0.6

REPETIDA

1.5 0.7

REPETIDA

1.35

REPETIDA
Gcp y Gcp

FAV.

0.9

1.5 0.7

1.5

Qcp

DESF.

Qcwi

DESF.

0.9

0.9

1.5 0.7

10

0.9

0.9

11

0.9

0.9

12

0.9

0.9

1.5

1.5 0.6

Gcp y Gcp

FAV.

Qcp

FAV.

Qcwd

DESF.

Gcp y Gcp

FAV.

Qcp

DESF.

Qcwi

DESF.

1.5 0.6

REPETIDA

1.5 0.7

REPETIDA

REPETIDA

Los autores, 1998; Edicions UPC, 1998.

59

Acciones

4.3 Comparacin de resultados


A continuacin se presentan los esfuerzos obtenidos segn las dos formas de clculo (esfuerzos
concomitantes y envolventes de mximos). Se dan los pares (N,M) en varias secciones de los tres
elementos (pilar izquierdo, dintel y pilar derecho). Los puntos pequeos representan los pares
concomitantes reales, mientras que las cruces grandes

equivalen a combinaciones de valores

mximos (Nmx,Mmx) obtenidos de envolventes. Como se ve, se obtienen valores mximos que en
ocasiones son irreales y que en algn caso (dintel, seccin x=3) pueden resultar inseguros de cara
al dimensionamiento.
RESULTADOS DEL PILAR IZQUIERDO
P. IZ. X=1

-160

-110

-60

-10

175

175

125

125

75

75

25

25

P. IZ. X=0

-25

-150

-100

-50

-75

-75

-125

-125

-175

-175

P. IZ. X=3

-100

-50

175

175

125

125

75

75

25

25

0 -25

P. IZ. X=2

-150

0 -25

-150

-100

-50

0 -25

-75

-75

-125

-125

-175
N

-175
N

Los autores, 1998; Edicions UPC, 1998.

60

Hormign armado y pretensado. Ejercicios

P. IZ. X=4

P. IZ. X=5

175

175

125

125

75

75

-150

-100

0 -25

-50

25

25

-150

-100

0 -25

-50

-75

-75

-125

-125

-175

-175

RESULTADOS DEL DINTEL

DINTEL X=1

225

225

175

175

125

125

75

75

DINTEL X=0

25
-30

-20

-25

-10

10

20

25
-30

-20

-25 0

-10

-75

10

20

10

20

-75

-125
-125

-175

-175
N
N

225

225

175

175

125

125

75

75

DINTEL X=3

DINTEL X=2

25
-30

-20

-25 0

-10

10

20

25
-30

-20

-25 0

-10

-75

-75

-125

-125

-175

-175

Los autores, 1998; Edicions UPC, 1998.

61

Acciones

225

225

175

175

125

125

75

75

DINTEL X=5

DINTEL X=4

25
-30

-20

-25 0

-10

10

20

25
-30

-20

-25 0

-10

-75

-75

-125

-125

-175

10

20

-175

DINTEL X=6

225
175
125

75
25
-30

-20

-25 0

-10

10

20

-75
-125
-175
N

RESULTADOS DEL PILAR DERECHO

P. DER. X=0

P. DER. X=1
45

45

25

25

-105

-55

-5

-15

5
-155

-155

-105

-55

-5

-15

-35

-35

-55

-55

-75

-75

Los autores, 1998; Edicions UPC, 1998.

62

Hormign armado y pretensado. Ejercicios

P. DER. X=2

P. DER. X=3
45

45

25

25

-105

-55

-5

-15

5
-155

-155

-105

-55

-5

-35

-55

-55

-75

-75

P. DER. X=4

P. DER. X=5
45

45

25

25

-105

-55

-5

-15

5
-155

-15

-35

-155

-105

-55

-5

-15

-35

-35

-55

-55
-75

-75
N

Los autores, 1998; Edicions UPC, 1998.

Acciones

63

Ejercicio I-4 Obtencin de leyes de esfuerzos en una viga continua de hormign


armado
Para cruzar una va urbana se proyecta una pasarela peatonal de hormign armado consistente en
una viga continua de dos vanos de 9.0 y 12.0 metros, con seccin constante como indica la figura
adjunta. El tablero se apoya sobre dos aparatos de apoyo de material elastomtrico, separados 1.20
m transversalmente (que permiten el movimiento horizontal y el giro de flexin en los estribos) y
sobre un nico apoyo centrado sobre la pila intermedia, que no permite movimientos longitudinales
pero s giros de flexin y torsin.
Las acciones que se deben considerar son:
- peso propio del tablero: 41.5 kN/ml,
- cargas muertas (pavimento, aceras, barandillas, instalaciones): 3.5 kN/ml,
- sobrecarga de uso extendida sobre cualquier rea del tablero en sentido longitudinal o
2

transversal: 4.0 kN/m ,


- variacin trmica de +20C en la fibra superior y +10C en la inferior.
Adoptaremos los coeficientes de mayoracin de acciones establecidos en la instruccin EHE, y
supondremos un control intenso de la ejecucin y para un hormign HA-30/P/20/II. Tomar

y0=0.6, y1=0.5, y2=0.2 como coeficientes para determinar los valores representativos de
combinacin, frecuentes y cuasi permanentes.

Alzado longitudinal

A = 18125 m

-2

I = 8.37610
v=-0.476 m
v = 0.324 m

Seccin del tablero

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado

64

Se pide:
1. Obtener las leyes de esfuerzos con las que se deben dimensionar las armaduras del tablero en
estado lmite ltimo.
2. Obtener las leyes de esfuerzos necesarias para la comprobacin de los estados lmite de servicio
para la combinacin poco probable.
3.

Calcular

las

reacciones

mxima

mnima

en

los

apoyos

extremos,

necesarias

para

el

dimensionamiento de los aparatos de apoyo en la combinacin de acciones poco probable.

Solucin
1. Las leyes de esfuerzos que han de utilizarse en el dimensionamiento se obtienen combinando
adecuadamente las leyes o envolventes de esfuerzos que provoca cada una de las acciones que se
consideran en el proyecto de la estructura. Por ello, lo primero que se har es obtener las leyes de
esfuerzos provocadas por cada una de las cargas.
A fin de simplificar el clculo de esfuerzos, no se tendrn en cuenta las acciones horizontales sobre
el tablero (frenado, etc.) y la pila (viento, deformaciones impuestas debidas a la variacin de
temperatura, retraccin, etc.). De esta forma no se consideran los esfuerzos horizontales que los
aparatos de apoyo transmiten a la pila, por lo que sta nicamente se ver sometida a esfuerzos
axiles. Por ello, se calculan primero las leyes de momentos flectores, los esfuerzos cortantes y
momentos torsores. Posteriormente se obtiene la envolvente de axiles para la pila.
Leyes de esfuerzos debidas al peso propio del tablero

606.94

443.54

Leyes de esfuerzos debidas a las cargas muertas

9.83

37.38

Los autores, 1998; Edicions UPC, 1998.

Acciones

65

Envolventes de las leyes de esfuerzos debidas a la sobrecarga de uso


Dado que la sobrecarga de uso puede extenderse sobre cualquier rea del tablero, tanto longitudinal
como transversalmente, han de considerarse las envolventes de todas las leyes de esfuerzos posibles.
No obstante, como el dimensionamiento se hace sobre las secciones crticas, los valores de los
esfuerzos nicamente se calculan en estas secciones, y el resto de la envolvente se dibuja de forma
cualitativa.

82.31

127.31

34.74

205.74

Leyes de esfuerzos debidas a la variacin trmica


La variacin trmica se considera que puede dividirse en una variacin uniforme y un gradiente de
temperaturas:

La variacin uniforme de temperatura no provoca esfuerzos puesto que la estructura puede


considerarse longitudinalmente isosttica. As pues, nicamente provoca esfuerzos el gradiente de
temperaturas.

39.26

235.75

235.75

52.35

471.15

Como el nivel de control es intenso, los coeficientes parciales de seguridad en estado lmite ltimo
para las acciones que se consideran son:
- cargas permanentes:
- cargas variables:

gG = 1.35

gQ = 1.50

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado

66

Envolvente de momentos flectores


-1239.48 =1.35 MI + 1.35 M II + 1.5 M II

638.75

1187.75

1.35 M I + 1.35 M II + 1.5 M IV+1.50.6 MIII


Envolvente de esfuerzos cortantes

449.22:1.35 (V I+V II)+1.5 V III+1.5 0.6 V IV

-318.2:1.35 (V I+ V II)+ 1.5 V III+1.5 0.6 V IV


Envolvente de momentos torsores

Envolvente de axiles en la pila

1130.88 kN

2. Se procede de forma anloga a lo hecho anteriormente. En este caso, al tratarse de estados lmite
de servicio, se consideran los siguientes coeficientes de seguridad:
- cargas permanentes:
- cargas variables:

gG = 1.0

gQ = 1.0

Envolvente de momentos flectores

Los autores, 1998; Edicions UPC, 1998.

Acciones

67

-892.3

395.186

828

Envolvente de esfuerzos cortantes

321

225.07

Envolvente de momentos torsores

Envolvente de axiles en la pila

813.98 kN

pp + cm + sc = 61 kNm

3. Para el dimensionamiento de los aparatos de apoyo han de considerarse los esfuerzos en estado
lmite de servicio.
En la pila intermedia la mxima reaccin se da cuando actan el peso propio, las cargas muertas y
la sobrecarga extendida en los dos vanos, con lo que se obtiene un axil mximo de valor Nmx =
813.98 kN. Por el contrario, la reaccin mnima, que resulta ser de Nmn = 426.16 kN, se produce
cuando nicamente actan el peso propio y el gradiente de temperaturas.

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado

68

mx

mn = 462.16 kN

= 813.98 kN

En el apoyo extremo del vano de 9 m, la reaccin es mxima (Nmx = 225.07 kN) cuando actan
conjuntamente el peso propio, la carga muerta, el gradiente de temperatura y la sobrecarga de uso
extendida en el vano de 9 m. La reaccin mnima se produce cuando acta el peso propio
combinado con la sobrecarga extendida en el vano de 12 m, y toma el valor de Nmn = 101.02 kN.

mn = 101.02 kN

mx = 225.07 kN

En el apoyo extremo del vano de 12 m se obtiene la reaccin mxima cuando se consideran la


accin conjunta del peso propio, la carga muerta, el gradiente de temperatura y la sobrecarga
extendida en el vano de 12 m. El valor que se obtiene es Nmx = 321 kN. La reaccin mnima
resulta ser Nmn = 192.63 kN, cuando acta el peso propio junto con la sobrecarga extendida al
vano de 9 m.

mx = 321 kN

Los autores, 1998; Edicions UPC, 1998.

mn = 192.63

kN

69

Materiales

Ejercicio I-5 Deformaciones del hormign. Estudio a nivel probeta

Una probeta cilndrica de hormign en masa, de 20 cm de dimetro y 40 cm de altura, se mantiene


a 20C durante los 120 primeros das posteriores a su fabricacin, para a continuacin elevarse la
temperatura a 30C y mantenerse constante.
Las cargas que actan en el transcurso del tiempo son las siguientes:
- a los 28 das, una compresin de 200 kN;
- a los 240 das, se retiran 80 kN.
La probeta se encuentra en un ambiente con un 70% de humedad relativa.
Se considerarn f (28 das) = 25 MPa y f (240 das) = 27 MPa.
ck

ck

Se pide:

Calcular las deformaciones que experimenta la probeta a los 360 das y a largo plazo.

Nota:

Se despreciarn las deformaciones instantneas remanentes.

Los autores, 1998; Edicions UPC, 1998.

70

Hormign armado y pretensado. Ejercicios

La deformacin total producida en un elemento de hormign es suma de diversas deformaciones


parciales que pueden clasificarse como se indica en la siguiente tabla:
Deformaciones
Independientes de la tensin
Dependientes de la tensin
Instantneas
Diferidas
Reversibles
Termohigromtricas
Elsticas
Fluencia
Irreversibles
Retraccin
Remanentes
(*) Se desprecian, en este problema, las deformaciones instantneas remanentes.
En todo lo que sigue se considerarn positivas las deformaciones de traccin o expansin y
negativas las de compresin o acortamiento.
(*)

Solucin

1 Deformaciones independie ntes de la tensin


1.1

Termohigromtricas

Slo se tendr en cuenta el efecto de la temperatura, considerndose un coeficiente de dilatacin


trmica de valor a = 10 C . Desde el inicio hasta los 360 das, y a largo plazo, slo se produce
un aumento de temperatura de 10C, por lo que:
eD = aDT = 10 10 = 10
-5

-5

1.2

-1

-4

Retraccin

El valor e (t ,t) de la retraccin efectiva de un elemento de hormign desde el instante t hasta la


edad t de su evaluacin viene dado por la expresin siguiente, segn la instruccin espaola EHE:
e (t ,t) = e b (t-t )
donde:
e = e b es el coeficiente bsico de retraccin y se evala como
e = (570-5f )10 = (570-525)10 = 4.4510

HR
70
b = - 1 . 55 1 -
= - 1 . 55 1 -
= -1.02

100
100

e = -4.5410
t-t
b (t - t ) =
0.035 e + (t - t ) define la evolucin temporal de la retraccin.
cs

cs

cs0

cs0

RH

-6

ck

-6

-4

RH

-4

cs0

Los autores, 1998; Edicions UPC, 1998.

71

Materiales

2A
u

= 100 mm
A = p100 = 31415.92mm es el rea de la seccin transversal
u = 2p100 = 628.32 mm es el permetro en contacto con la atmsfera.
La retraccin es efectiva desde el primer da (t = 0 das) y se evala en dos instantes:
t = 360 das b (t-t ) = 0.71
t = 10000 das b (t-t ) = 0.98
Con estos valores se obtienen los siguientes valores para la retraccin:
t (das)
360
10000
-4.4510
-3.2210
e (0,t)
e=

-4

cs

2 Deformaciones dependient es

-4

de la tensin

Las deformaciones dependientes de la tensin, en el instante t, para una tensin constante s(t )
aplicada en el instante t se pueden evaluar mediante la siguiente expresin, basada en el principio
de linealidad:
0

1
j (t, t
+
E
E

e s = s (t )
C

28

donde el primer trmino se corresponde con las deformaciones instantneas elsticas, y el segundo
con las diferidas tensionales o de fluencia.
Para estimar estas deformaciones se aplica el principio de superposicin. As, se considera un
primer estado consistente en la actuacin de una carga de compresin de 200 kN (s = -6.37 MPa)
a los 28 das. El segundo estado se corresponde con una traccin de 80 kN (s = 2.546 MPa),
aplicada a partir de los 240 das.
c

2.1

Instantneas elsticas

Estado I
e =
I

(t = 28)

= -1.9910
E
s (t = 28 das) = -6.37 MPa
E = 10000(f ) = 10000(25+8) = 32075.34 MPa
0

-4

28

28

cm,28

1/3

1/3

Los autores, 1998; Edicions UPC, 1998.

72

Hormign armado y pretensado. Ejercicios

Estado II
s

e =
II

(t = 240 )

= 0.7810
E
s (t = 28 das) = 2.55 MPa
E = 10000(27+8) = 32710.66 MPa
0

-4

240
0

1/3

240

2.2

Deformaciones debidas a la f l uencia

Estado I
Las deformaciones debidas a fluencia en el instante t para una tensin constante s (t ) aplicada en t
se evalan segn la instruccin EHE como:
s( t )
e j ( t, t ) =
E j(t, t )
donde:
j (t,t ) = j b (t-t ) es el coeficiente de fluencia para t = 28 das.
j = j b(f )b(t ) es el coeficiente bsico de fluencia
100 - HR = 1 + 100 - 70 = 1.65
j =1+
9.9 e 9.9 (100 )
16.8 = 16.8 = 2.92
b(f ) =
f + 8 25 + 8
1 = 1 = 0.489
b( t ) =
0.1 + t 0.1 + 28
j = j b(f )b(t ) = 2.36
(t - t )
b (t - t ) =
,
b + (t - t )
0

28

RH

cm

RH

1/ 3

1/ 3

cm

ck

0.2

0.2

RH

cm

0.3

funcin que describe el desarrollo de la fluencia con el tiempo.


b =1.5e[1+(0.012HR) ]+250 = 406.5
Considerando la fluencia efectiva desde t = 28 das, y evalundola para
t = 360 das b (t-t ) = 0.79
t = 10000 das b (t-t ) = 0.99
se obtienen unos coeficientes de fluencia para el estado I, j (t,28):
18

Los autores, 1998; Edicions UPC, 1998.

73

Materiales

t (das)

360
1.86

j (t,28)
I

10000
2.34

Estado II
Para el estado II la fluencia es efectiva desde t = 240 das:
j ((t,t ) = j b (t-t )
j = j b(f )b(t ) = 1.54
j = 1.65
b(f )=2.92
1
b( t = 240 ) =
0.1 + 240 = 0.32
(t - t )
b (t - t ) =

b + (t - t )
b = 406.5
La fluencia se evala para los siguientes instantes:
b (t-t ) = 0.64
t - t = 360 - 240 = 120 das
t - t = 10000 -240 = 9760 das b (t-t ) = 0.99
y se obtienen unos coeficientes de fluencia para el estado II, j (t,240):
t (das) 360 10000
0.99 1.53
j (t,240)
0

RH

cm

RH

cm

0.2

0.3

II

II

Como la tensin es s (t=240) = 80000


= 2.55 MPa , la deformacin se puede calcular mediante
f
P
4
s
la expresin ej (t,240 ) = E j(t,240 ) .
2

240
28

Con estos resultados, y aplicando el principio de superposicin, se obtienen las siguientes


deformaciones debidas a la fluencia:
t (das)
360
10000
-4.6610
-3.6910
e j (t,28)
1.2210
0.7910
e j (t,240)
-3.4410
-2.910
e j(t,t )
c

-4

-4

II

-4

Los autores, 1998; Edicions UPC, 1998.

-4

-4

-4

74

Hormign armado y pretensado. Ejercicios

3 Deformacin total

La deformacin total ser la suma de deformaciones parciales:


e
= eD + e + e +e j + e + e j
Deformaciones
t = 360 das
Temperatura
+10
Retraccin
-3.2210
Instantnea elstica
Estado I
-1.9910
Estado II
0.7810
Fluencia
Estado I
-3.6910
Estado II
0.7910
TOTAL
-6.3310
TOTAL

cs

II
i

II

-4

-4
-4

-4

-4

-4

-4

Los autores, 1998; Edicions UPC, 1998.

t = 10000 das
+10
-4.4510
-1.9910
0.7810
-4.6610
1.2210
-8.110
-4

-4
-4

-4

-4

-4

-4

75

Materiales

Ejercicio I-6 Problema de relajacin y fluencia

Sea un elemento vertical de hormign de seccin 15x15 cm y longitud 75 cm. Dicho elemento se
encuentra biempotrado y se construye con un hormign de 25 MPa, fabricado con un cemento de
endurecimiento rpido. Tras su hormigonado y curado se sumerge en agua, y puede considerarse
que la retraccin y el entumecimiento comienza a 1 da de edad.
Se pide:

Realizar un estudio de la evolucin de tensiones en el hormign con el paso del tiempo.


Solucin

1 Clculo de la retraccin/ e l
e

cs

(t , t ) = e
s

cso

entumecimiento

(t - t )
s

t = comienzo de la retraccin, en das = 1 da


t= edad del hormign, en das
s

cso

= e b
s

e = (570 - 5 f
S

RH

cso

RH

ck

) 10

-6

= 4.45 10

= 0.25 (entumecimiento)
= 0.00011

luego,

-4

(t - ts) = 0.035 te- +ts (t - ts)


2

e = 2 u A = 75mm
b

-1
(t - 1) = 195.t875
+t

-1
(1, t ) = 0.00017 195.t875
+t
Para realizar estudios en el tiempo, se opta por tomar intervalos que proporcionen un mismo De .
Para un hipottico tiempo infinito:
e

cs

cs

Los autores, 1998; Edicions UPC, 1998.

76

Hormign armado y pretensado. Ejercicios

t e
a=

cs

cs mx

cs mx

= 0.00011

t -1
1 + 195.88 a
t + 195.88 [0,1] t = 1 - a

La ltima ecuacin proporciona el tiempo transcurrido desde el origen de tiempos, necesario para
que se produzca una deformacin por entumecimiento de ae . Tomando incrementos de
deformacin constante, por ejemplo
1 2 3 4 9
a = 0, , , , ,...,
10 10 10 10 10
cmx.

se calculan los intervalos de tiempo en los que se produce una deformacin constante del 10% de la
deformacin a tiempo infinito.
Esto aparece reflejado en la siguiente tabla:
a
t, das

cs

1/10

2/10

3/10

4/10

5/10

6/10

7/10

8/10

9/10

9.2

20.5

38.5

66.6

111.5

190.2

351

840.3

1.110

-5

2.210

-5

3.310

-5

4.410

-5

5.510

-5

6.610

-5

7.710

-5

8.810

-5

9.910

-5

1.110

-5

Las deformaciones por entumecimiento aparecen representadas en la siguiente grfica:


DEFORMACIONES POR ENTUMECIMIENTO
1,20E-04
1,00E-04
8,00E-05
6,00E-05

EPScs(t)

4,00E-05

INCEPScs(t)

2,00E-05
0,00E+00
1

10

100

1000

10000

100000

1000000

10000000

das

2 Clculo del mdulo de def ormacin longitudinal

Cuando se resuelva el problema en trminos de fluencia o de relajacin se precisar conocer la


evolucin del mdulo de deformacin en el tiempo.

Los autores, 1998; Edicions UPC, 1998.

77

Materiales

Segn la EHE y el cdigo modelo MC-90, el mdulo de deformacin longitudinal inicial del
hormign se puede obtener mediante la siguiente expresin:
E = 10000 f
f = f +8
donde todas las magnitudes estn expresadas en MPa.
En nuestro caso, f =25 MPa, luego:
E = 32075 MPa
3

c 28

cm

cm

ck

ck

c 28

En funcin del tiempo, se tiene:


E = bE
c ,t

c 28

donde se adopta para cemento de endurecimiento rpido:


das 3
7 28 90
365
1000
10000 20000
0.74 0.87 1
1.07 1.09 1.2
1.21
1.215
b
Por lo tanto, para los intervalos de tiempo que se tienen, se obtiene interpolando:
das 3
9.2 20.5 38.5 66.6 111.5 190.2 351
840.3
0.74 0.88 0.954 1.012 1.044 1.072 1.077 1.089 1.17
b
E 23700 28200 30600 32500 33500 34300 34600 34900 37500
Estos valores aparecen reflejados en la siguiente grfica:
c, t

E(t)

4 00 00
3 50 00
3 00 00

MPa

2 50 00
2 00 00
1 50 00
1 00 00
5 00 0
0
0

2 00

4 00

6 00

8 00

1 00 0

d a s

Los autores, 1998; Edicions UPC, 1998.

78

Hormign armado y pretensado. Ejercicios

3 Clculo del coeficiente de

fluencia

Para cualquiera de los dos mtodos de resolucin se precisar conocer los distintos valores del
coeficiente de fluencia.
Segn el cdigo modelo CM-90 y la norma EHE, se tendr:
j( t, t ) = j b ( t - t )
0

En nuestro caso:
2.92
j( t, t ) =
0.1 + t
0

RH

cm

0.3

0.2

j = j b(f ) b( t
j = 1 ( HR = 100 )

t-t

1500 + t - t

) = 16.8 = 2.92
f +8
1
b( t ) =
0.1 + t
RH

b(f

(t - t

b = 1500

ck

0.3

cm

) = b t+-tt- t

(HR = 100)

0.2

En el grfico siguiente se presentan las distintas funciones de fluencia para los escalones de tiempo
determinados. Se aprecia que:
a) los valores de j son mayores cuanto ms temprana es la edad de carga;
b) las distintas funciones de j obtenidas no son una traslacin de la primera j (t,t =3): las
funciones varan (son cada vez menores) conforme aumenta t .
0

COEFICIENTE DE FLUENCIA
1,80

FI(t,t0=3)
1,60

FI(t,t0=9.2)
1,40

FI(t,t0=20.5)
1,20

FI(t,t0=38.5)
1,00

FI(t,t0=66.6)
0,80

FI(t,t0=111.5)

0,60

FI(t,t0=190.2)

0,40

FI(t,t0=351)

0,20

FI(t,t0=840.3)

0,00
0

100

200

300

400

500

600

700

800

das

Los autores, 1998; Edicions UPC, 1998.

900

79

Materiales

4 Resolucin del problema e n

trminos de relajacin

La relajacin es un fenmeno complementario al de fluencia. Consiste en la relajacin de tensiones


que se produce en el tiempo a partir de una tensin inicial provocada por una deformacin impuesta.
La ecuacin constitutiva del hormign, planteada en trminos de una historia de deformaciones, es
la siguiente:
s

(t ) = e (t ) R(t, t ) + R(t, t' ) de (t' )


t

t0

lo que es una generalizacin del principio de superposicin ante una historia de deformaciones
cualquiera.
e(t)

e(t0)
t

t0

La funcin R(t,t ) se llama funcin de relajacin y se puede evaluar con suficiente precisin a travs
de la siguiente expresin:
0

R ( t, t ) = E ( t
0

) 1

f (t, t )
E (28) + c f (t, t
E (t )
0

componente

componente

instantnea

diferida

donde c es el coeficiente de envejecimiento, evaluable segn la ecuacin:


c=

(valores entre 0.5 y 1.0)

1+ t

Para edades de carga comprendidas entre 10 y 30 das (t ), c vale aproximadamente 0.8 (Trost).
0

Los autores, 1998; Edicions UPC, 1998.

80

4.1

Hormign armado y pretensado. Ejercicios

Historia de deformaciones

La retraccin (entumecimiento) aumenta continuamente en el tiempo. Para hacer un anlisis paso a


paso en el tiempo se adoptar la siguiente hiptesis: en cada hito de tiempo (t) se producir toda la
deformacin desarrollada entre t y t .
i

i-1

4.2

Anlisis paso a paso

Cuando en t = 3 das aparece la deformacin por entumecimiento (De (3)), en la pieza aparece una
tensin de compresin. Esta tensin se relaja con el paso del tiempo.
Cuando en t =9.2 das aparece De (9.2) se genera una nueva tensin de compresin, que tambin
se relajar con el paso del tiempo.
El balance de tensiones en t =9.2 das ser:
tensin relajada evaluada en t = 9.2

tension que aparece


+ y aparecida en t = 3 por el primer

en t = 9.2 por De (9.2)


escalon de deformacion De (3)
0

cs

cs

cs

cs

Grficamente:
s

f1: funcin final de la tensin relajada


aparecida a 3 das

primer escaln

diferida
instantnea

Los autores, 1998; Edicions UPC, 1998.

81

Materiales

segundo escaln

f2: funcin final de la tensin relajada


aparecida a 9.2 das

instantnea

9.2

9 2
9.2

s
suma
f1 + f 2
escalones
iguales

9 9.2
2

este incremento es
mayor que el de 3
das puesto que E
crece con el tiempo

f1

9.2
2
9

En el siguiente escaln de tiempo aparece una nueva De y se repite el proceso.


cs

4.3

Solucin planteada.

De (3)
s (f )
De (9.2)
s (f )

3 das
(3)R(3,3)
0
0
De (3)R(3,3)

De

cs

cs

cs

...
Suma por columnas
s

cs

total

9.2 das
(3)R(9.2,3)
De (9.2)R(9.2,9.2)
0
De (3)R(9.2,3)+
De (9.2)R(9.2,9.2)
De

cs

cs

cs

cs

20.5 das
(3)R(20.5,3)
De (9.2)R(20.5,9.2)
...
De (3)R(20.5,3)+
De (9.2)R(20.5,9.2)+
De (20.5)R(20.5,20.5)
De

cs

cs

cs

cs

cs

El valor de R(t ,t ) coincide con E(t ) puesto que f(t ,t ) = 0.


0

Los autores, 1998; Edicions UPC, 1998.

82

Hormign armado y pretensado. Ejercicios

Para resolver el problema se debe, por tanto, calcular las funciones de relajacin R(t,t ) que
aparecen a continuacin. Obsrvese que los puntos iniciales de cada curva R(t,t ) coinciden con el
valor de E(t ) segn la curva que se ha dado en pginas anteriores:
0

FUNCIN DE RELAJACIN
45 00 0

MPa

40 00 0

R (t,t0= 3 )

35 00 0

R (t,t0= 9 .2)

30 00 0

R (t,t0= 2 0.5 )
R (t,t0= 3 8.5 )

25 00 0

R (t,t0= 6 6.6 )
20 00 0

R (t,t0= 1 11 .5)

15 00 0

R (t,t0= 1 90 .2)

10 00 0

R (t,t0= 3 51 )
R (t,t0= 8 40 .3)

50 00
0
0

20 0

40 0

60 0

80 0

10 00

das

4.4

Resolucin numrica

En la grfica siguiente se observan los resultados:

TENSIONES POR RELAJACIN


0

-1

-2

MPa

-3
tens sin rel
-4

tens con rel

-5

-6
0

100

200

300

400

500

600

das

Los autores, 1998; Edicions UPC, 1998.

700

800

900

83

Materiales

La curva tens con rel representa el sumatorio por columnas a cada edad planteado en el cuadro
anterior. Proporciona la tensin real del elemento en cualquier edad, teniendo en cuenta la
relajacin.
La curva tens sin rel representa la tensin en cada instante sin considerar la relajacin. Es decir,
es la suma acumulada de las tensiones instantneas obtenidas en cada paso de tiempo. Obsrvese la
diferencia importante entre esa curva y la anterior. De ah la necesidad de tener en cuenta los
fenmenos diferidos del hormign en los anlisis estructurales.

5 Resolucin del problema en

trminos de fluencia

Cuando aparece la deformacin por entumecimiento en un tiempo t, para compatibilizar la situacin


se genera una tensin que introduce una deformacin mecnica instantnea igual (y de sentido
contrario) al entumecimiento. El balance en deformaciones es, por tanto, nulo y en tensiones
aparece una compresin.
Si tenemos en cuenta la fluencia, en cada escaln de tiempo se debe considerar la deformacin
diferida que introduce cada tensin aparecida en intervalos anteriores. Por lo tanto, la nueva tensin
que aparezca en ese escaln deber introducir una deformacin instantnea igual y contraria al
balance de todas las deformaciones presentes.

5.1

Planteamiento

Como se sabe,
llamada

e(t)=s(t0)J(t,t0),

funcin de fluencia y
J( t, t 0 )

1
E( t 0 )

y resulta vlido el principio de superposicin. La funcin J es la

se expresa por:

f( t, t 0 )
E ( 28)

, donde

J(t,t0) = componente de deformacin instantnea + componente de deformacin diferida


J(t,t0) y es aproximadamente igual a 1/E (variable).

Los autores, 1998; Edicions UPC, 1998.

84

Hormign armado y pretensado. Ejercicios

FUNCIN DE FLUENCIA
0,00014

0,00012

J(t,t0=3)

0,0001

J(t,t0=9.2)
J(t,t0=20.5)
0,00008
1/MPa

J(t,t0=38.5)
J(t,t0=66.6)
J(t,t0=111.5)

0,00006

J(t,t0=190.2)
J(t,t0=351)
0,00004

J(t,t0=840.3)

0,00002

0
0

100

200

300

400

500

600

700

800

900

das

Para el problema actual las distintas funciones J aparecen en la grfica anterior. Se observa que los
puntos iniciales de las curvas son cada vez de menor valor con el paso del tiempo (cuanta ms edad
tiene el hormign, menores deformaciones instantneas y diferidas tiene).
La solucin del problema se plantea como sigue, si:

Decs(t): incremento de deformacin por entumecimiento entre el escaln de tiempo t -Dt y t;


Ds(t): tensin que aparece en t tras realizar el balance parcial de deformaciones;
em(t,t0): deformacin mecnica en t provocada por la aparicin de Ds(t0) en t0 ;
em(t0,t0): la deformacin instantnea;
Dem(t,t0): incremento de deformacin mecnica entre t y t-Dt.
Se puede expresar como: em(t,t0)-em(t-Dt,t0) y corresponde exclusivamente a la deformacin diferida.
Situacin a 3 das:

De

cs

(3)

Balance parcial Decs(3)

Los autores, 1998; Edicions UPC, 1998.

85

Materiales

Debe aparecer una tensin que introduzca una deformacin instantnea igual y contraria al

balance parcial
Ds(3)=-Decs (3)E(3)

em (3,3)=Ds(3)J(3,3)

Balance en deformaciones:
e(3) = Decs(3)+Dem(3,3)+De(0) = 0
Balance en tensiones:
s(3) = Ds(3) + s(0) = Ds(3)
Situacin a 9.2 das:

Decs(9.2)

Aparece un incremento de deformacin (diferida) provocada por

Ds(3) entre t = 3 y t= 9.2.

Dem(9.2;3)=em(9.2,3)-em (3,3)=
Ds(3)J(9.2,3)-Ds(3)J(3,3)

Balance parcial Decs(9.2)+ Dem(9.2,3)


Debe aparecer una tensin que introduzca

una deformacin instantnea igual y contraria al

balance parcial
Ds(9.2)=-(Dem(9.2,3)+Decs(9.2))E(9.2)

em(9.2,9.2)=Ds(9.2)J(9.2,9.2)

Balance en deformaciones:
e(9.2) = Decs(9.2) + Dem(9.2,3) + em(9.2,9.2) + e(3) = 0
Balance en tensiones:

Los autores, 1998; Edicions UPC, 1998.

86

Hormign armado y pretensado. Ejercicios

s(9.2) = Ds(9.2) + s(3)


Situacin a i das:
Decs(i)

Aumento de la deformacin diferida por la carga en t=3:


Dem(i,3)=em(i,3)-em(i-Dt,3)=
Ds(3)J(i,3)-Ds(3)J(i-Dt,3)

Aumento de la deformacin diferida por la carga en t=9.2:

Dem(i,9.2)=em(i,9.2)-em(i-Dt,9.2)=
Ds(9.2)J(i,9.2)-Ds(9.2)J(i-Dt,9.2)

Aumento de la deformacin diferida por la carga en t=i- t:

Dem(i,i-Dt)=em(i,i-Dt)-em(i-Dt,i-Dt)=
Ds(i-Dt)J(i,i-Dt)-Ds(i-Dt)J(i-Dt,i-Dt)

Balance parcial:
j = i - Dt

De cs (i ) + De m (i,3) + De m (i,9.2 ) + ... + De m (i, i - Dt ) = De m (i, j )


j =3

Debe aparecer una tensin que introduzca una deformacin instantnea igual y contraria al

balance parcial:
j=i-

Dt

Ds(i)=-SDem(i,j)E(i)
j=3

em(i,i)=Ds(i)J(i,i)

Balance en deformaciones:
e(i) = Decs(i) + Dem(i,3) + Dem(i,9.2) + ... + em(i,i- Dt) + em(i, i) + e(i- Dt) = 0

Los autores, 1998; Edicions UPC, 1998.

87

Materiales

Balance en tensiones:
s(i) = Ds(i) + s(i-Dt)
En la grfica siguiente se presenta la solucin del problema en trminos de fluencia. La curva tens
sin flu representa las tensiones acumuladas sin tener en cuenta los fenmenos de fluencia. La curva
tens con flu representa la solucin teniendo en cuenta los fenmenos diferidos. Las tracciones
finales aparecen por la escala de intervalos tomados. La tensin de compresin final aproximada es
de 2 MPa, que coincide muy sensiblemente con la obtenida segn la funcin aproximada de
relajacin que se ha tomado.

TENSIONES EN t
0

-1

-2

MPa

TENS (t) con flu

-3

TENS(t) sin flu

-4

-5

-6
0

200

400

600

800

das

Los autores, 1998; Edicions UPC, 1998.

1000

89

Anlisis estructural

Ejercicio I-7 Prdidas instantneas y diferidas en una viga con armaduras postesas

Una viga simplemente apoyada de hormign pretensado debe salvar una luz de 25 m. Sobre ella
actan, adems del peso propio (8,5 kN/m), una carga muerta de 1.5 kN/m, una sobrecarga de uso
de 2 kN/m y una carga puntual mvil de 100 kN.
Se adopta una solucin 2de hormign pretensado con armaduras postesas constituidas por 4 tendones
T52 F 0.6 (Ap=28 cm ). El trazado equivalente de dichas armaduras sigue la ecuacin y =0.0032
x - 0.08 x, tal como se aprecia en la figura adjunta.

Caractersticas de la seccin:
Ac = 0.34 m24
v = 0.67 m
Ic = 0.062 m
v = -0.58 m
La fuerza de pretensado inicial a la salida del gato, antes de anclar, es de 2200 kN. Los tendones se
tesan de dos en dos. La penetracin de cua es de 5 mm.
Los materiales empleados son:
- hormign HP-45/P/20/IIb
fck= 45 MPa
- armadura activa Y 1860 S7
fPmx = 1860 MPa, fPyk = 1700MPa
Nota: se considerarn los siguientes valores de las propiedades mecnicas del hormign:
Mdulo de deformacin longitudinal: Ec= 40000 MPa
Deformacin unitaria de retraccin final: ecs = - 0.0003
Coeficiente de fluencia: j = 2.
Las propiedades de la armadura activa son:
Mdulo elstico: Ep= 200000 MPa
Relajacin final: r = 8%
Coeficiente de friccin angular: m = 0,2
Ondulacin k/m = 0.015 rad/m.

Los autores, 1998; Edicions UPC, 1998.

90

Hormign armado y pretensado. Ejercicios

Se pide:

1. Calcular las prdidas instantneas y diferidas de la fuerza de pretensado en las secciones central y
de apoyo.
Solucin

1 Prdidas instantneas de l a
1.1

fuerza de pretensado

Prdidas por rozamiento

Se pueden evaluar mediante la expresin:


DP1 = P0[1-exp(-ma-Kx)]
En la seccin de apoyo tanto x como a son nulos, por lo que no hay prdida de fuerza de pretensado
debido al rozamiento.
Por lo que se refiere a la seccin de centro de vano (x=12.5 m), la variacin angular se obtiene
como:
a(x=12.5m) = y(12.5m) - y(0) = 0.08
Teniendo adems en cuenta que, resultando una prdida de pretensado en x=12.5 m, de valor
DP1 = P0 (1 - e - 0.20.08 + 0.00312.5 ) = 114.61
(

1.2

kN

Prdidas por penetracin de cuas

Dado que se trata de armaduras postesas, se evala esta prdida considerando que el rozamiento al
destesar el tendn es igual al rozamiento al tesar.

Los autores, 1998; Edicions UPC, 1998.

91

Anlisis estructural

La ecuacin que permite encontrar la longitud lp que se ve afectada por la prdida al penetrar las
cuas es
a = Dl = 0l EDP(Ax) dx @ 2 D EP2 lAp
p p
p
p
Teniendo en cuenta que DP2 = 2(PA-PB) = 2PA (1 - e k l ) , y sustituyendo en la expresin
anterior, se obtiene la siguiente ecuacin que hay que resolver:
- (m a +

kl
a = PA [1 -Ee A ] l p
- (ma +

donde:

p)

p)

a = 5 mm (penetracin de la cua)
lp : longitud de influencia de la penetracin de cua
Ap = 2800 mm2
Ep = 200000 Mpa.
Resolviendo esta ecuacin en lp, se obtiene:
lp = 17.57 m
DP2 = 2DPB(x=17.57m) = 318.74 kN.
As, la prdida en la seccin de apoyo es DP2(x=0) = 318.74 kN.
La prdida en el centro de la viga se obtiene de la siguiente manera:

Los autores, 1998; Edicions UPC, 1998.

92

Hormign armado y pretensado. Ejercicios

l
D' D = AC D' D = AC lp - 2 = AC 1 - l
2 lp
lp

l p - 2l lp
25 = 91.97 kN

DP2D = D' D = 318.74 1 2 17.57


PD = PA DP1D DP2D = 2200 114.61 91.97 = 1993.42 kN
1.3

Prdidas por acortamiento el stico del hormign

Estas prdidas se pueden estimar mediante la siguiente expresin, considerando que todos los
tendones experimentan un acortamiento uniforme:
n - 1 Ap E p
DP3 = s cp
2 n E cj
donde:

n=2 (los tendones se tesan dos a dos, simtricamente)


P - DP1 - DP2 - (P0 - DP1 - DP2 ) e 2 - M pp e
s cp = - 0
Ac
Ic
Ic
En la seccin de apoyo:
PC = PA-DP1-DP2 = 1881260 N
e=0
Mpp = 0
1881260 = -5.53 MPa
s cp = 340000
2 - 1 2800 200000 = -19355 N
DP3 = -5.53
2 2 40000
En la seccin de centro de vano:
PD = PA-DP1-DP2 = 1993420 N 2
e = y(12.5) = 0.003212.5 0.0812.5 = -0.5 m = -500 mm
Mpp = 664062.5 Nm
1993420 - 1993420 (- 500 ) 2 - 664062500 (- 500 ) = -8.55 MPa
s cp = 340000
62 10 9
62 10 9
2 - 1 2800 200000 = -29925 N
DP3 = -8.55
2 2 40000
Ntese que se est considerando la actuacin en este momento del peso propio.

Los autores, 1998; Edicions UPC, 1998.

93

Anlisis estructural

Estos resultados, referentes a las prdidas instantneas de fuerza de pretensado, se recogen en la


siguiente tabla:
Pki (kN)
Seccin
DP2 (kN)
DP3 (kN)
DPinst (kN)
DPinst / P0
DP1 (kN)
Apoyo
0
-318.74
-19.35
-338.11
-15.4 % 1861.9
Central
-114.61
-91.97
-29.92
-236.5
-10.8 % 1963.5
1.4

Prdidas diferidas de la fuerz a de pretensado

Se realiza una evaluacin conjunta de las prdidas diferidas, considerndose una formulacin que
tiene en cuenta de forma aproximada la interaccin entre las prdidas debidas al acortamiento del
hormign por retraccin y fluencia, y a la relajacin del acero de las armaduras activas:
n j s cpg + E p e cs + 0.8 Ds pr A
DPdif =
p
2
A
p A c y p
1 + n A 1 + I (1 + c j)
c
c
donde:
n = Ep / Ec = 5 (coeficiente de equivalencia)
P P e 2 - M pp cm e
s cgp = - ki - ki
Ac Ic
Ic
P
Ds pr = -r ki
Ap
c = 0.8
(coeficiente de envejecimiento)
Sustituyendo los valores correspondientes en la seccin de apoyo se obtiene:
scgp = -5.47 MPa
Pki = 1861894 N
e = yp = 0
Mpp+cm = 0
Dspr = -53.20 MPa
5 2 (-5.47) + 2 10 5 (-3 10 4 ) + 0.8 (-53.20) 2800 = -397746 N
DPdif =
0.34 0 2
0
.
0028
1 + 5 0.34 1 + 0.062 (1 + 0.8 2 )

Por lo que se refiere a la seccin de centro de vano:


scgp = -7.39 MPa
Pki = 1963500 N
e = yp = -500 mm

Los autores, 1998; Edicions UPC, 1998.

94

Hormign armado y pretensado. Ejercicios

Mpp+cm = 781250 Nm
Dspr = -56.1 MPa
5 2 (-7.39) + 2 10 5 (-3 10 -4 ) + 0.8 (-56.1) 2800 = -399243 N
DPdif =
0.34 ( -0.5) 2

1 +
1 + 5 00.0028
0.062 (1 + 0.8 2 )
.34
En la tabla siguiente se resumen los resultados obtenidos en el problema:
Seccin de apoyo
Seccin centro de vano
Prdidas instantneas (kN)
338.11 (15.4%)
236.5 (10.7%)
Prdidas diferidas (kN)
397.75 (18.0%)
399.24 (18.1%)
Pretensado final (kN)
1464.14
1564.26
33.4
28.9
DP/P0 (%)

Los autores, 1998; Edicions UPC, 1998.

95

Anlisis estructural

Ejercicio I-8 Prdidas instantneas y diferidas en una viga con armaduras pretesas

Los elementos resistentes de un forjado unidireccional son viguetas de hormign pretensado de 4


metros de luz simplemente apoyadas, cuyas seccin transversal y caractersticas de los materiales se
indican en el esquema adjunto. El intereje es de 50 cm.
Las propiedades de los materiales son las siguientes:
- hormign: HP-35/S/12/I, (f = 35 MPa, a los 28 das), j = 2,5, e = 410
- armaduras activas: alambres de f = 4 mm de acero superestabilizado (r=8%), de f =
1700 MPa, y f = 1900 MPa, tesados a una tensin s = 0.75 f .
ck

-4

pyk

pu

po

pu

Seccin transversal
de la vigueta

Las cargas actuantes, adems del peso propio de las viguetas, son:
- carga muerta permanente: 1.5 kN/m
- sobrecarga variable: 2.0 kN/m
Se toman Y =0.6, Y =0.5, Y =0.2 como coeficientes de combinacin de acciones.
2

Se pide:

1. Calcular las caractersticas mecnicas de las secciones bruta (A, I, v, v) y homogeneizada


(A , I , v , v ).
h

Los autores, 1998; Edicions UPC, 1998.

96

Hormign armado y pretensado. Ejercicios

2. Calcular las prdidas por acortamiento elstico y las prdidas diferidas de pretensado.
3. Calcular los momentos que hay que aplicar a la vigueta para que se produzca el estado lmite de
descompresin y el estado lmite de aparicin de fisuras. Verificar si dicha vigueta, en el forjado
descrito, satisface dichos estados lmite.
4. Calcular las tensiones en las fibras extremas del hormign antes y despus de transferir el
pretensado, y a largo plazo, suponiendo que actan la totalidad de las cargas.
Solucin

1 Las caractersticas mecni cas de la seccin bruta son las siguientes:

A = 11250 mm
v = -84.16 mm
v = 95.84 mm
I = 37893228 mm
El rea de pretensado es A =30.7854 = 37.7 mm , y su excentricidad equivalente es:
e = 1 (95.84 - 20 ) +32 (95.84 - 165) = -20.83 mm .
Si se consideran los siguientes valores del mdulo de deformacin longitudinal:
- hormign: E =8500f =8500(35+8) = 29778.88 Mpa
- acero de las armaduras activas: E = 200000 MPa
- coeficiente de equivalencia: n = E /E = 6.72
se obtienen las caractersticas de la seccin homogeneizada de la siguiente forma:
2

1/3
cm,j

1/3

Centro de
gravedad

Los autores, 1998; Edicions UPC, 1998.

97

Anlisis estructural

rea homogeneizada:
A = A + (n-1)A = 11250+(6.72-1)37.7 = 11465.64 mm
Tomando momentos estticos respecto de la fibra superior se puede obtener el centro de gravedad:
.84 + 5.72 37.7 116.67 = 96.23 mm
v = A A v ++((nn--11))AA v = 11250 95
11250 + 5.72 37.7
v = v h = -83.77 mm
El momento homogeneizado de inercia se obtiene como sigue:
h

I = I + A (v-v ) + (n - 1) A e = 38991959 mm
h

pi

i =1

hi

As pues, las caractersticas de la seccin homogeneizada son:


A = 11465.64 mm
v = -83.77 mm
v = 96.23 mm
I = 38991959 mm
2

2 Las prdidas se calcularn

en la seccin centro de vano, que es la crtica.

El valor de la excentricidad del trazado equivalente del pretensado en la seccin homogeneizada es


e = e + (v v) = -20.44 mm.
Momentos actuantes en la seccin centro de vano debidos a las diferentes acciones, sin mayorar:
- peso propio:
pp = 250.011250 = 281.25 N/m
M = pp8 l = 562.5 Nm
- cargas muertas:
cm = 15000.5 = 750 N/m
M = cm8 l = 1500 Nm
- sobrecarga variable: sc = 20000.5 = 1000 N/m
M = sc8 l = 2000 Nm
h

pp

cm

sc

La fuerza de pretensado inicial es:


P = s A = 0.75f A = 0.75190037.7 = 53722.5 N
0

p0

pu

Los autores, 1998; Edicions UPC, 1998.

98

2.1

Hormign armado y pretensado. Ejercicios

Prdidas por acortamiento el stico

DP3 =scp A p

Ep
E cj

= -5.2637.7

scp = -

200000
29778.88

= -1332.83 N

P0 P0 e2
= -5.26MPa
Ah
Ih

Fuerza de pretensado despus de la transferencia: P = P + DP = 52389.67 N.


ki

2.2

Prdidas diferidas

Se calculan mediante la siguiente expresin, que permite tener en cuenta la interaccin entre
fluencia y retraccin del hormign y la relajacin del acero de pretensado:
DPdif =

scgp = c = 0.8

Dspr

n j(t, t 0 ) s cgp + E p e s (t, t 0 ) + 0.8 Ds pr


A p = -8315.1 N
A p
y 2p
1+ n
1+ A
(1 + c j(t, t 0 ))
h Ih
A h

Pki Pki e2 M pp + cm e
= -4.05MPa
Ah
Ih
Ih

(coeficiente de envejecimiento)
P
= -r
= -111.17 MPa
A
f

ki

Fuerza de pretensado final: P = P + DP = 44074.66 N


Por lo tanto, las prdidas instantneas de fuerza de pretensado representan un 2.5% sobre el
pretensado inicial; mientras que las diferidas alcanzan el valor de un 15.5% respecto al mismo valor
de la fuerza de pretensado en anclajes.
k

ki

dif

3 El momento de descompres in de la seccin se calcula con la siguiente expresin:

r2h

M 0 = -Pk

v'h

Los autores, 1998; Edicions UPC, 1998.

+ e

99

Anlisis estructural

El momento de descompresin depender de la fuerza de pretensado, por lo que ser distinto a corto
y a largo plazo, esto es:
- despus de la transferencia (P = 0.95P = 49770.19): M = 3037.8 Nm
- largo plazo (P = 0.95P = 41870.93): M = 2555.65 Nm
La expresin del momento que provoca el inicio de la fisuracin en la seccin es la que sigue:
k

ki

0i

r2h

M = -Pk

v'h

+ e - f ct

Ih
v' h

Resistencia caracterstica a traccin del hormign: f =0.21f =2.25 MPa


Resistencia a traccin a los 7 das: f =b f = 0.72.25 = 1.58 MPa
Resistencia a traccin a largo plazo: f = bf = 1.12.25 = 2.48 MPa
Con estos valores se obtiene:
- despus de la transferencia (P = 0.95P = 49770.19 N): M = 3773.23 Nm
- largo plazo (P = 0.95P = 41870.93 N): M = 3710 Nm
A la hora de verificar los estados lmite se tiene en cuenta la combinacin de acciones simplificada
que viene recogida en la instruccin EHE para las situaciones:
- frecuente:
Sg G + g P + y g Q
- casi permanente:
Sg G + g P + y g Q
Los coeficientes que se utilizan en la verificacin son los que se indican en la siguiente tabla:
Coeficientes g
g
g
y
y
Valores
1.0
1.0
0.95
0.5
0.2
Sin considerar el pretensado, las combinaciones anteriores proporcionan los siguientes momentos de
clculo en los estados lmite de servicio:
- situacin frecuente: M = 3062.5 Nm
- situacin casi permanente: M = 2462.5 Nm
Se considera adems una combinacin nicamente con las cargas permanentes: M = 2062.5 Nm.
La siguiente tabla recoge la verificacin de los estados lmite de descompresin y apertura de fisuras
para las diferentes combinaciones.
2/3

ct,k

ct.7

ct,k

ct.

ct,k

ck

ki

G,j

k,j

1,1

Q,1

k,1

G,j

k,j

2,1

Q,1

k,1

G,j

Q,1

1,1

2,1

fr

cp

Los autores, 1998; Edicions UPC, 1998.

100

Hormign armado y pretensado. Ejercicios

Estado lmite
EL descompresin
EL apertura de fisuras

Frecuente
No
S

Casi permanente
S
S

C. Permanentes
S
S

4 Tensiones en el hormign

Las tensiones en el hormign se calculan con la siguiente frmula:


g P
g P e
M
s =+
y - y
A
I
I
donde A e I son el rea y la inercia de la seccin considerada en cada fase.
p

4.1

Antes de la transferencia

Acciones:
s =0

- pretensado en la armadura activa

4.2

Despus de transferir (secci n homogeneizada)

- pretensado P = 52389.67 N; e = -20.44 mm


- peso propio: 281.25 N/m

Acciones:

ki

-2.95 MPa

s
s

c,sup
c,inf

= -2.95 MPa
= -5.32 MPa
-5.32 MPa

4.3

Largo plazo (seccin homoge n eizada). Consideramos la situacin frecuente.

Acciones:

- pretensado P = 44074.66 N; e = -20.44 mm


- peso propio: 281.25 N/m
- cargas muertas permanentes: 750 N/m
- sobrecarga variable: 1000 N/m
k

Los autores, 1998; Edicions UPC, 1998.

101

Anlisis estructural

-8.88 MPa

s
s

c,sup
c,inf

= -8.88 MPa
= 1.79 MPa
1.79 MPa

5 Tensiones en el acero

Las variaciones de tensin en el acero se obtienen como:


Ds = nDs (y=e )
donde n = E /E = 6.72 es el coeficiente de equivalencia.
p

5.1

Antes de la transferencia (sec c in de la armadura activa)

Acciones:
- pretensado en el acero
Si se admite relajacin nula del primer da:
P = 1425 MPa
s =s =
A
o

5.2

p0

Despus de transferir (secci n homogeneizada)

Variacin de acciones:

- pretensado P
- peso propio: 281.25 N/m
ki

Ds = -30.11 MPa
s = 1394.89 Mpa
p

5.3

Largo plazo (seccin homoge n eizada)

Variacin de acciones:

- prdidas diferidas de pretensado DP


- cargas muertas permanentes: 750 N/m
- Sobrecarga variable: 1000 N/m
dif

Ds = 17.53 MPa
s = 1412.42 MPa
p

Los autores, 1998; Edicions UPC, 1998.

103

Anlisis estructural

Ejercicio I-9 Cargas y esfuerzos debidos al pretensado en estructuras isostticas


Una viga simplemente apoyada debe resistir, adems de su peso propio, una carga uniformemente
repartida de 10.0 kN/ml extendida en toda su longitud. Para ello se disea una solucin de
hormign pretensado con armaduras postesas, cuyo trazado equivalente es el de la figura adjunta, y
cuyas caractersticas geomtricas y mecnicas son:
4

v = 0.67 m

ea = 0.20 m

v = -0.58 m

ec = -0.48 m

Ic = 0.062 m
Ac = 0.34 m

Se supone que no existe rozamiento entre tendn y vaina. El trazado est compuesto por 3 parbolas
tangentes en l/4 y en 3l/4 (en donde no necesariamente la excentricidad deber ser nula) y con
pendiente nula en los apoyos y en centro de luz.

Se pide:
Determinar las cargas y esfuerzos de pretensado en la estructura, si la fuerza de pretensado es
P=1000 kN.
Criticar el trazado del tendn basndose en las cargas actuantes, la geometra y las condiciones de
vinculacin de la viga.

Solucin
1. El trazado equivalente del cable viene definido por la siguiente ecuacin, con las unidades en
metros:

Los autores, 1998; Edicions UPC, 1998.

104

Hormign armado y pretensado. Ejercicios

- 0.008704 x - 0.2176 x - 1.16 , -12.5 m x -6.25

e( x ) = 0.008704 x - 0.48 , -6.25 m x 6.25 m

- 0.008704 x + 0.2176 x - 1.16 , 6.25 m x 12.5 m


2

Nota: Obsrvese que para x=6.25 e(x)=-0.14 m.

Cargas de pretensado

Las cargas de pretensado se pueden dividir en dos grupos:

P = P cos a

- cargas concentradas en los anclajes P = P sen a


M = P e

normales : n =
- cargas distribuidas a lo largo del trazado
r
tangenciales : t = -m n

h
v

En este caso, al no considerarse rozamiento entre tendn y vaina, t = 0. Por otra parte, se supone
que las cargas distribuidas normales son aproximadamente verticales, ya que la pendiente del tendn
es muy pequea.

1
r

- 0.017408 , -12.5 m x -6.25

e'' ( x ) = 0.017408 , -6.25 m x 6.25 m


- 0.017408 , 6.25 m x 12.5 m

P
r

- 17.408 , -12.5 m x -6.25

= 17.408 , -6.25 m x 6.25 m


- 17.408 , 6.25 m x 12.5 m

m
-1

radio de curvatura en m

m
carga distribuida normal (kN/m)

Los autores, 1998; Edicions UPC, 1998.

105

Anlisis estructural

Esfuerzos de pretensado

Dado que se trata de una estructura isosttica, los esfuerzos de pretensado se pueden obtener en
cada seccin directamente como:

a
a
V = -Psena
M = Pecos
N = -Pcos

donde:
1

cos

a=

sen

a=

+ tg a
2

tg
1

+ tg a
2

=
=

1
1

+ (e' ( x ))
( e' ( x ))

+ (e' ( x ))

A partir de estas expresiones se obtienen los esfuerzos de pretensado que se recogen en los
siguientes grficos.

Momentos flectores debidos al pretensado


-600,00

M-max=480 kNm

M (kNm)

-400,00

-200,00

0,00

200,00

M+max=200 kNm

Los autores, 1998; Edicions UPC, 1998.

106

Hormign armado y pretensado. Ejercicios

Esfuerzos axiles debidos al pretensado


-1250,00

N (kN)

-1000,00

-750,00

-500,00

-250,00

0,00

Esfuerzo cortante debido al pretensado

-150,00

V (kN)

mx= 108.8 kN

-100,00

-50,00

0,00

2. A la hora de analizar el trazado de pretensado se aprecian dos aspectos poco adecuados: la


longitud de la contracurva y la excentricidad en la zona de apoyos.
Por lo que se refiere al primer aspecto, parece que el hecho de disponer la contracurva tiene como
objeto llegar con pendiente nula a la zona de apoyos. No obstante, esta decisin parece errnea,
puesto que no se aprovecha el efecto beneficioso de reduccin del cortante que se obtiene al dar una
cierta inclinacin al pretensado, precisamente en la zona crtica frente a este tipo de esfuerzo. Una
buena solucin sera llegar con una pequea pendiente al eje del apoyo, acabando con pendiente casi
nula en el extremo de la viga.
Por otra parte, la contracurva no es eficaz puesto que provoca unas cargas verticales descendentes,
que no compensan las cargas a exteriores, sino que tienden a aumentar la solicitacin que stas

107

Anlisis estructural

provocan. Adems, al estar el punto de inflexin demasiado alejado del apoyo, este efecto se ve
acentuado.
Finalmente, el hecho de dar una excentricidad al pretensado en la zona de apoyos (ea = 20 cm)
provoca una elevacin general del trazado en secciones intermedias, por lo cual el efecto beneficioso
del pretensado disminuye. No obstante, se observa que la fuerza de pretensado es interior al ncleo
central. Adems, si hubiese rozamiento las prdidas seran innecesariamente aumentadas.
As pues, se considera que el trazado ms adecuado sera aquel con dos curvaturas, situado el punto
de inflexin cercano a la vertical del apoyo. De esta forma se puede conseguir una cierta pendiente
en la zona de apoyos, llegando con pendiente nula al extremo de la viga, con lo cual se facilita la
operacin de tesado. Finalmente, se dispondra excentricidad nula en zona de apoyos.

Los autores, 1998; Edicions UPC, 1998.

109

Anlisis estructural

Ejercicio I-10 Hiperestticos de pretensado. Trazado concordante. Viga continua


Para reducir el nmero de pilares en la planta baja de un edificio y resistir las cargas puntuales Q
por ellos transmitidas, se disea una viga continua de hormign pretensado de seccin rectangular,
con armaduras postesas de trazado equivalente poligonal, tal como indica la figura adjunta. No se
consideran prdidas instantneas ni diferidas.

Se pide:
1. Obtener los esfuerzos hiperestticos de pretensado en la viga.
2. Calcular la relacin entre e1 y e2 para obtener un trazado concordante.
3. Predimensionar el valor de la fuerza de pretensado por el mtodo de compensacin de cargas
Q = 400 kN, despreciando el peso propio de la viga.
4. Con el valor de P antes calculado, si e1=0.4 h , e2=0.4 h y l=10 m, calcular el valor de la
carga exterior Q para la que se producir la primera fisura.

Nota:

se adoptarn los siguientes valores de las propiedades mecnicas del hormign:


- resistencia a compresin fc,k = 35 MPa
- resistencia a traccin fct,k = 3 MPa
- mdulo de deformacin longitudinal Ec = 35000 MPa

Solucin
1. Se efecta el clculo del momento hiperesttico de pretensado a partir de las curvaturas
impuestas

c por el pretensado en cada seccin:

Los autores, 1998; Edicions UPC, 1998.

110

Hormign armado y pretensado. Ejercicios

x
dJ A = 1 - L dJ
dJ A x = dJ B (L - x )

x
dJ = dJ A + dJ B
dJ = dJ
B L

J = cdx =

P ( x ) e( x )
E I

dx

x P e( x )
dJ A = 1 - L E I dx


dJ = x P e( x ) dx
B L E I

Si se toman e1 y e2 positivas hacia arriba, el trazado del pretensado viene definido por la siguiente
ecuacin:
l
e1
2 l x , 0 x 2

2 ( e 2 - e 1 ) x + 2 e - e , l x l
1
2

2
l
e( x ) =
e1 - e 2
*
*

x + e2 , 0 x l
l
e
- 1 x * + 2 e 1 , l x * 2 l x * = x - l
l
Imponiendo la compatibilidad de giros sobre el apoyo central, debidos al pretensado y al momento
hiperesttico, se tiene:

Los giros que provoca el pretensado en cada tramo son:

Los autores, 1998; Edicions UPC, 1998.

111

Anlisis estructural

JPI = 0ldJ I = 02
l
2

e( x )

EI

x
l

dx + l 2

e x
P
P x
l
2 1 2 dx + l

EI
EI l
l
2
2

J PII = 02 l dJ II = 0l

P e( x )

E I

e( x )

EI

x
l

dx =

Pl
e - e1

2 2
x + 2 e 1 - e 2 dx =
EI
l

5 e2
e
1 +
24
4

x
x
2 l P e( x )

1 1 dx + l
dx =
2

l
E

I
2
l

x
x


e
e - e2
2l P
- 1 x + 2 e 1 1 1
x + e 2 1 dx =
dx + l
EI l
2l
2l
l
P l e1 5 e 2
+

E I 2
12

l
0

P
EI

La compatibilidad de giros en el apoyo obliga a la aparicin de un momento hiperesttico de forma


que:

e1 5 e 2 M H l
+
+

24
3E I
4

e
5
e
M

P
l

2
J II = J PI + J MII = 1 +
- H
EI 2
12
3EI

J I = J PI + J MI =

P l

E I

J I = J II

De donde:

MH =

3
- P e1 + e 2
8

2. El trazado concordante es aquel que provoca una reaccin hiperesttica nula; esto es, no existe
momento hiperesttico:

MH = 0

3
4

e1 + e 2 = 0 e1 = - e 2

3. Las cargas de pretensado habrn de compensar las cargas puntuales.

a tgai

sen i

Los autores, 1998; Edicions UPC, 1998.

112

sen

Hormign armado y pretensado. Ejercicios

a1 = -

e1
l

a2 =

2 (e 2

sen

a3 =

e2

sen

a4 = -

sen

- e1 )

= P (sen a 1 + sen a 2 ) = 2 P

e2

- 2 e1
l

- e1
l

e1

= P (sen a 3 + sen a 4 ) = P

e2

- 2 e1
l

Ambas ecuaciones conducen a idntica solucin:

Q
2

l
e2

- 2 e1

= 200

l
e2

- 2 e1

donde P viene expresado en kN y l,e1 y e2 en metros.


4. Con los datos concretos del problema (e1 = -0.4 m, e2 = 0.4 m y l = 10 m), se obtiene una
fuerza de pretensado de valor P = 1666.67 kN. Las acciones a las que se ve sometida la viga
continua son las que se observan en la figura:

R1 = 2 P

R2 = P

e2

e2

- 2e
l

- 2 e1
l

= 400

= 200

kN

kN

Por lo tanto, la viga se ve sometida a las siguientes cargas:

p=250.4=10 kN/m

que provocan los siguientes esfuerzos:

Los autores, 1998; Edicions UPC, 1998.

113

Anlisis estructural

0.3125 pl

Impondremos que en las secciones crticas no se alcance una tensin superior a la resistencia
caracterstica a traccin del hormign.
2

A = 0.4 m

I = 0.0333 m

Seccin 1:

s sup = -

1666 .67
0.4

30
16

(Q - 400 ) - 375
0.0333

0.5 = fct,k = 3000

kN
m

Q = 454.56 kN
50
Seccin 2:

s inf = -

1666 .67
0.4

32

(Q - 400 ) + 312.5
0.033

( -0.5) = f ct ,k = 3000

kN
m

Q = 505.47 kN
Por lo tanto, la primera fisura se producir para una carga Q = 454.56 kN, en la fibra superior de
la seccin del apoyo central.
Si el problema lo resolviesemos separando los esfuerzos isostticos e hiperestticos de pretensado
tenemos:
a) Momentos debidos al pretensado

Los autores, 1998; Edicions UPC, 1998.

114

Hormign armado y pretensado. Ejercicios

donde el momento hiperesttico en el apoyo central MH se ha obtenido como:

MH

3
= -P e1 +
4

5
8

3
e 2 = -P (- 0.4 h ) +

5
8

0.4 h =

h=

0.05 P

MH = 0.051666.671 = 83.33 kNm


b) Momentos debidos a las cargas exteriores

En la seccin de apoyo la situacin ser:

ssup = -

P
A

(P e

+ M H + MQ ) v
I

= fct

Pe2 = 666.67 kN m
MH = 83.33 kNm
MQ = -375 - 1.88Q
Despejando se obtiene el valor de Q = 454.56 kN.

Por su parte, en la seccin de vano tendremos:

s inf = -

P
A

(P e

+ MH,v + MQ ) v'
I

= fct

Pe1 = -666.67 kNm


MH,v = 0.5MH = 41.67 kNm
MQ = 312.5 + 1.56Q
En este caso se obtiene Q = 505.47 kN.

Por tanto, al igual que se obtiene por el mtodo de las cargas, la primera fisura se producir en la
fibra superior de la seccin de apoyo para un valor de Q = 454.56 kN.

Los autores, 1998; Edicions UPC, 1998.

115

Anlisis estructural

Ejercicio I-11 Esfuerzos de pretensado en un prtico biempotrado


Dado el prtico de la figura adjunta (cuyo dintel est pretensado), en el que se considera que no
existe rozamiento entre la armadura activa y el hormign, se sabe que la fuerza en los anclajes es
Panc = 150 T.

SECCIN A-A

SECCIN B-B

ALZADO DINTEL (TRAZADO DEL TENDN)

Se pide:
1. Calcular el sistema de cargas de pretensado sobre el hormign.
2. Calcular las leyes de esfuerzos de pretensado (para el instante inicial).

Los autores, 1998; Edicions UPC, 1998.

116

Hormign armado y pretensado. Ejercicios

Solucin

1 Sistema de cargas sobre el hormign


a) Clculo de la ecuacin del trazado del tendn.

y = ax 2 + bx + c
y = 2ax + b
Condiciones:

= 0 y (0 ) = 0 c = 0
x = 12.5 y (12.5 ) = -0.4
a = 0.00256

x = 12.5 y(12.5 ) = 0
b = -0.064

= 0.00256x 2 - 0.064x

b) Cargas sobre el hormign


q

@ P y = 0.00512 P

= 0.768 T m = 7.68 kN / m
tga = y (0 ) = -0.064

sen a = -6.3869 10 - 2
cos a = 0.998

luego

a = 149.694 T = 1496.94kN
P sena = 9.58T = 95.8kN

P cos

2 Leyes de esfuerzos de pret ensado


El clculo de estas leyes se aborda resolviendo el prtico sometido a las acciones de pretensado. Des
esta forma se obtienen las

leyes totales (esfuerzos isostticos + esfuerzos hiperestticos).

Tomamos la siguiente notacin y convenio de signos:

= Id =

1
12

0.5 13 = 4.166 10 -2 m 4

Inercia del dintel

= I p = 121 0.5 0.5 3 = 5.208 10 -2 m 4


Longitud del dintel = l d = 25 m

Inercia del pilar

Los autores, 1998; Edicions UPC, 1998.

117

Anlisis estructural

= lp = 6

Longitud del pilar

rea de la seccin del dintel


Sentido

= A d = 0.5 1.0 = 0.5 m 2

para giros y momentos:

Antihorario

Para resolver la estructura hallamos las ecuaciones elsticas teniendo en cuenta que:
- los giros en
- los giros en

A (fa) y en D (fd) son nulos;


B (fb) y en C (fc) son simtricos;

- el dintel, por efecto del pretensado, sufre un acortamiento que puede expresarse mediante un

d en B y C (simtricos)

movimiento

m ab

m ab

m ba

m ba

m bc

m bc

Puesto que

2 EI p
lp

2 EI p
lp

2EI p

4EI p

6EI p
lp

lp

2EI d

fb +

fa = 0
0

m ab

= 0 (mom. de emp. perfecto)


(1)

6EI p
lp

6 EI p
lp

lp

+ m ab0 , con

(2f b + f a ) +

lp

+ m 0ba ,

con

fa = 0
m 0ba = 0

(2)

(2f b + f c ) + m 0bc

ld

fb +

6 EI p

(2f a + f b ) +

2EI d

ql d

(2f b + f c ) -

ld

f b = -fc

(3)

12

por simetra y

m ba + m bc = 0

por equilibrio en el nudo

B,

se tiene

(ecuaciones 2 y 3):
4 EI p
lp

fb +

6EI p
lp

4 EI p

+
lp

d+

2 EI d
ld

2EI d
ld

f b =

fb -

ql d

12

ql d

12
6 EI p
lp

=0

Por otra parte, descomponiendo la estructura:


Equilibrio en el nudo B:

Los autores, 1998; Edicions UPC, 1998.

(4)

118

Hormign armado y pretensado. Ejercicios

N bc

d=
m ba

+ Vba = P cos a

N bc

ld

EA d

(5)

N bc =

2EA d

(6)

ld

- Vba l p + m ab = 0 Vba =

m ba

+ m ab

(7)

lp

Introduciendo (6) y (7) en (5) tenemos:


m ba

+ m ab

lp
6 EI p
lp

fb +

2EA d

ld

12 E I p
lp

d+

= P cos a
2 EA d
ld

d = P cos a

de donde

fb =

P cos

a lp2

6EI p

Ad lp

3I p l d

(8)

lp

Introduciendo (8) en (4) tenemos

P cos a l p 2 A d l p 2 d 2d q l d 2 6 E I p

=
- 2 d

6 EI p
3I p l d
lp
lp

12
2
2
2
2EI d A d l p
P cos a l p I d
4EI d
ql d
2

=
- P cos a l p 2
lp ld
3
3l d I p
3I p l d
12

4 EI p 2 E I d

lp + ld

4E A d l p
3l d

8E I p
lp

Sustituyendo los valores antes calculados (Ap, lp, ld, Ip, Id, q, Pcos

Los autores, 1998; Edicions UPC, 1998.

a) obtenemos:

119

Anlisis estructural

d E =

- 598.776 - 57.479
-616.255
=
= 3277.952 T / m
-3
- 0.188
- 0.16 - 0.0116 - 0.10154 - 1.111 10
40

(9)

Sustituyendo en (4):
2
4I p 2I d
6I

Ef b = q l d - p Ed
+
2
lp
ld
12
lp

(0,0034722 + 0,0033328 )Ef b = 40 - 3,12387


Ef b = 5418,975

(10)

Sustituyendo (9) y (10) en (1), (2), (3), (7) hallamos los valores de esfuerzos:

m ab

m ba

m bc
Vba

2I p
lp
4I p
lp

f +

6I p

f +

6I p

E b

E b

lp

lp

d = 5.271 + 28.453 = 33.724 mT = 337.24 kNm

d = 10.542 + 28.453 = 38.955 mT = 389.95kNm

= -m ba = -38.995 mT = -389.95 kNm


+ m ab 33.724 + 38.995
m
= ba
=
= 12.12 T = 121.2 kN
lp

y, por ltimo, estableciendo el equilibrio en el dintel, obtenemos:

ql d
2
por lo que, equilibrando el nudo

= Vbc l d

Vbc

= 9,6T

B frente a fuerzas verticales,


N ba

+ Vbc = P sen a
N ba = P sen a - Vbc = 9.58 - 9.6 @ 0

(el pequeo error aparece por la simplificacin que supone tomar

q @ Py)

por lo tanto:
Leyes de esfuerzos:

Los autores, 1998; Edicions UPC, 1998.

120

Hormign armado y pretensado. Ejercicios

21 mT

Mf
39 mT

39 mT

33.72 mT

33.72 mT

137.57 T

9.6 T

V
12.12T

12.12 T

9.6 T

La diferencia con los isostticos de pretensado proporciona los hiperestticos de pretensado:

Los autores, 1998; Edicions UPC, 1998.

121

Anlisis estructural

Esfuerzos isostticos

Esfuerzos hiperestticos

Mf
39 mT

39 mT

33.72 mT

33.72 mT

12.12 T

V
12.12 T

Los autores, 1998; Edicions UPC, 1998.

12.12 T

Anlisis

123

Ejercicio I-12 Anlisis en el tiempo. Construccin evolutiva

Se proyecta un acueducto de hormign pretensado de un gran nmero de vanos iguales de 25 m de


luz, a base de vigas prefabricadas de seccin artesa. La construccin es evolutiva, de forma que los
elementos trabajan inicialmente bajo su peso propio como simplemente apoyados, para
posteriormente proporcionar continuidad estructural solidarizando unos elementos a otros a travs
de pretensado en la zona de apoyos. La figura adjunta muestra la geometra y la evolucin del
esquema estructural.

A = 1.308 m
I = 0.195 m
v = 0.87 m
v = -0.38 m
P = 9650 kN (despus de transferir)
A = 7140 mm (51 0.6)
e = 0 (pretensado centrado)
Seccin hidrulica 2m
2

El hormign es HP-45/P/18/II-b. Las armaduras de pretensado estn constituidas por 51 cordones


de 0,6, de acero Y 1860 S7 de carga unitaria mxima 1860 N/mm .
La transferencia del pretensado se realiza a los 7 das del hormigonado, quedando la viga biapoyada
a partir de ese momento. Posteriormente se transporta y se monta in situ, y a los 90 das se
bloquean las juntas, dando continuidad estructural al conjunto, instante a partir del cual puede entrar
en servicio el acueducto.
Las cargas que se deben considerar son:
2

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

124

- cargas permanentes: peso propio del acueducto (r =25 kN/m )


- sobrecargas de uso: peso del agua (q =20 kN/ml)
Se desprecian las prdidas diferidas de pretensado y se suponen los siguientes parmetros reolgicos
del hormign:
j (90, 7) = 1.2
j (, 7) = 2.0
j (, 90) = 1.4
c (90, 7) = 0.9
c (, 7) = 0.8
c (, 90) = 0.85
h

Se pide:

1. Calcular la ley de momentos flectores a corto y largo plazo bajo los efectos de las cargas
permanentes, supuesto que el pretensado de continuidad es tambin centrado. Utilizar el mtodo
del coeficiente de envejecimiento para obtener la fluencia producida por tensiones variables a lo
largo del tiempo.
2. Sin tener en cuenta el estado tensional local generado por el pretensado de continuidad, calcular
el estado de tensiones en las secciones crticas as como la flecha en centro de vano a corto y
largo plazo, en vaco y en servicio.
3. En funcin del apartado anterior disear el pretensado de continuidad (fuerza y excentricidad
necesaria, en su caso) para garantizar la ausencia de tracciones en apoyos y vano bajo cargas de
servicio y en vaco.
4. En caso de que el pretensado sea excntrico, situado por debajo del centro de gravedad de la
seccin pero dentro del ncleo central de la misma, obtener la expresin del momento
hiperesttico a largo plazo sobre el apoyo en funcin de la excentricidad, suponiendo que las
prdidas diferidas de pretensado son del 10%, a tiempo infinito y que a los 90 das se ha
producido la mitad de las mismas.
Solucin

1 Ley de momentos flectores a corto y largo plazo


1.1 Clculo de esfuerzos y despla zamientos en fase inicial y de propiedades mecnicas del
hormign

Peso propio g = 25 kN/m x 1.308 m =32.7 kN/m.


Momento flector en centro de vano
M = g 8l = 32.78 25 = 2554.69 kN m
3

Los autores, 1998; Edicions UPC, 1998.

Anlisis

125

Mdulo tangente de deformacin longitudinal, a diversas edades del hormign:


E
E
E

c,28

c,7

= 10000

c,28

+ 8 = 10000

= 0,8 E = 30050.29 MPa


= 1,09 E = 40943 .52 MPa

53 = 37562.86 MPa

c,28

c,90

c,28

Rigidez a flexin E I
(E I) = 7.325 10 kN m
(E I) = 5.860 10 kN m
(E I) = 7.984 10 kN m
c

28

90

Giro en los extremos al transferir el pretensado a t = t = 7 das


g l = 32.7 25 = 0.00363 rad
q( t ) =
24 E I 24 5.860 10
Desplazamiento vertical (flecha) en centro de la luz al transferir
5 g l = 5 32.7 25 = 0.0284 m = 28.4 mm
y(t ) = 384
E I 384 5.860 10
o

1.2 Calculo de esfuerzos a largo plazo

Al dar continuidad (a los 90 das) se impide, a partir de ese instante, el incremento de giro por
fluencia sobre los apoyos Dqj, para lo que se requiere la aparicin de un esfuerzo hiperesttico
DM , que genere un giro q , de forma que:
h

Dq j + q

Mh

Mh

=0

Ntese que se hace la hiptesis de que el comportamiento de la viga es similar al de una viga
biempotrada.
El valor de q , habida cuenta de su aparicin progresiva a partir de los 90 das es:
M l [1 + c(,90) j(,90)]
q ( ) =
2 (E I )
Dq ( ) = q [j(,7 ) - j(90,7 )]
Mh

Mh

90

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

126

Igualando Dqj = q se tiene


) - j(90,7 )
M = 2 (E l I ) J 1 +jc((,7,90
) j(,90 )

Mh

90

2 7.984 10 0.00363 2.0 - 1.2 = 846.96 kN m


25
1 + 0.85 1.4
Si el acueducto se hubiese construido inicialmente como viga continua, el momento flector negativo
sobre apoyos hubiese sido
M = - g12 l = - 32.712 625 = -1703.13 kN m
Ello significa que los efectos de la fluencia al dar continuidad posterior hacen que a lo largo del
tiempo se genere un momento flector negativo del 50% aproximadamente del que se hubiese
generado en caso de construcciones simultneas sobre cimbra.
El momento flector positivo ser entonces
M = g 8l - M = 2554.69 - 846.96 = 1707.73 kN m
La ley de momentos flectores a largo plazo ser, finalmente:
M

2 Estado tensional

En este apartado se considerar que el pretensado de continuidad se hace centrado y con la misma
fuerza que la del pretensado de la viga.

Los autores, 1998; Edicions UPC, 1998.

Anlisis

127

2.1 Situacin inicial (isosttica), en vaco


2.1.1 Seccin centro de vano

2554.69 0.38 = -2399.31 kN m


(x = 12.5m ) = - AP - M I v' = - 19650
+
.308
0.195
(x = 12.5) = - AP - M I v = -18775.52 kN m = -18.78 MPa
g

inf

= -2.40

sup

2.1.2 Seccin de apoyo

inf

(x = 0) = s (x = 0) = - AP
sup

= -7377.68 kN

= -7.38

MPa

2.2 Situacin final (continua), en vaco a largo plazo


2.2.1 Seccin centro vano

inf

P - M v' = - 9650 + 1707.73 0.38 = -4049.79 kN m = -4.05 MPa


A
I
1.308
0.195
P - M v = - 9650 - 1707.73 0.87 = -14996.78 kN m = -15 MPa
=A
I
1.308
0.195

=-

sup

2.2.2 Seccin de apoyo

inf

P - M v' = -7377.68 - 846.96 0.38 = -9028.16 kN m


A
I
0.195
P - M v = -7377.68 + 846.96 0.87 = -3598.93 kN m
=A
I
0,195

=-

= -9.03

MPa

= -3.60

MPa

sup

2.3 Situacin final (viga continua ) en servicio a corto plazo

Los momentos flectores M +


q

+
q

M q-

producidos por el agua son:

20 625 = 520.83 kN m ; M
24

-20 625

12

= -1041.67

Los autores, 1998; Edicions UPC, 1998.

kN m

MPa

Hormign armado y pretensado. Ejercicios

128

2.3.1 Seccin centro de vano

inf

P - M v' - M v' = -1384.36 kN m


A
I
I
P - M v - M v = -21099.22 kN m
=A
I
I
+

g o

=-

= -1.38

MPa

g o

sup

= -21.10

MPa

2.3.2 Seccin de apoyo

inf

P - M v' = -7378 - 1042 0.38 = -9407.6 kN m = -9.41 MPa


A
I
0.195
P - M v = -7378 + 1042 0.87 = -2730.23 kN m = -2.73 MPa
=0.195
A
I
-

=-

sup

2.4 Situacin final (viga continua ) en servicio largo plazo


2.4.1 Seccin centro de vano

inf

P - M v' - M v' = -3034.84 kN m


A
I
I
P - M v - M v = -17320.45 kN m
=A
I
I

=-

= -3.04

MPa

sup

+
q

= -17.32

MPa

2.4.2 Seccin de apoyo

inf

P - M v' - M v' = -1158.08 kN m = -11.06 MPa


A
I
I
P - M v - M v = 1048.52 kN m = 1.05 MPa
=A
I
I
g

=-

sup

Se observa que en la fibra superior en apoyos, en servicio a largo plazo, se produciran tracciones
de 1.05 MPa. Estas tracciones no superan la resistencia a traccin, cuyo valor es
f ct ,k

= 0.21

f ck

= 0.21

45

= 2.66

MPa

No obstante, por razones de estanqueidad conviene plantear soluciones para evitar tracciones como
se ver en el apartado 3.

Los autores, 1998; Edicions UPC, 1998.

Anlisis

129

2.5 Flecha en el centro del vano

La flecha instantnea al pretensar es de 28.4 mm, tal como se calcul ms arriba. A largo plazo, la
flecha debida a cargas permanentes estar compuesta por las debidas a la carga repartida y al
momento hiperesttico, segn la expresin:
d (t ) = d (t ) + d (t )
d ( t ) = d (t ) (1 + j (t, t )) = 28.4 (1 + 2.0) = 85.2 mm
d (t ) = d (t ) (1 + c (t, t ) j ( t, t )) = -8.39(1 + 0.85 1.4) = -18.16
M l
846.96 625
d (t ) =
8 (E I) = - 8 7.984 10 10 = -8.29 mm
d (t ) = 85.2 - 18.16 = 67.04 mm
g

Mh

Mh

Mh

Mh

90

que representa 1/373 de la luz.


La sobrecarga de agua, acta sobre la viga continua, generando una flecha.
ql
20 25
d =
384 E I = 384 7.984 10 10 = 2.55 mm
Con lo que la flecha mxima previsible ser
d = d (t ) + d = 67.04 + 2.55 = 69.6 mm , que resulta ser 1/360 de la luz.
4

3 Pretensado de continuidad

Basndose en los resultados anteriores el pretensado de continuidad centrado con valor igual al de la
viga no basta para mantener la fibra superior en la seccin de apoyos comprimida en la situacin en
servicio a largo plazo.
Si se introdujese un pretensado adicional centrado, su fuerza debera ser:
P 1050 kN m ; P 1440 kN
A
c

La longitud del pretensado de continuidad no debera sobrepasar la de la zona sometida a momentos


negativos. Aproximadamente se puede evaluar:

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

130

M(x) = -846.96 + 32.7 12.5 x - 32.7 x2 = -846.96 + 408.75 x - 16.35 x


M(x) = 0
para x = 2.28 m @ 10l
2

Para reducir el postensado de continuidad adicional necesario, y por razones constructivas, ste
podra situarse en la cabeza superior, donde tiene mayor eficacia por la excentricidad.

Debido a la excentricidad e = 0.72 m respecto del centro de gravedad se generan, adems, efectos
hiperestticos, tanto en cuanto a esfuerzos como en cuanto a flechas.
El momento hiperesttico generado se obtiene igualando el giro debido al momento que introduce el
pretensado con el giro que introduce el momento hiperesttico. Esto es equivalente a igualar las
reas de las leyes de momentos. De este modo:
M = 2 P e ll
La flecha en centro de vano ser la generada por el sistema de cargas de la figura, cuyo valor ser
p

P e l 4 l - 2 l
=
8EI l l
2

M = P e1 - 2 ll
a

Los autores, 1998; Edicions UPC, 1998.

Anlisis

131

El pretensado de continuidad se obtiene obligando a satisfacer el estado limite de descompresin en


la seccin de apoyo, esto es obligando a que se genere unas compresiones de valor 1.05 MPa. De
este modo:
P P e v + M v = 1.05 MPa
s =0=- A
I
I
c

sup

de donde puede despejarse: P =315 kN.


Con lo que el momento hiperesttico y flecha resultan
M = 2 P e ll = 2 226.8 0,1 = 45.4kN m
315 0.72 25 [4 0.1 - 2 0.1] = -0.35 mm
d =
8 7.984 10
c

hip

Para obtener el estado tensional despus de la continuidad, habr que aadir al calculado en el
apartado 2) las tensiones producidas por el pretensado de continuidad adicional, las cuales, sin
considerar prdidas diferidas, son:
3.1.1 Seccin centro vano (solo afecta el momento hiperesttico)

sup

M v = 45.4 0.87 = 202 kN m = 0.2 MPa


I
0.195
M v' = - 45.4 0.38 = -88 kN m = -0.88 MPa
=
I
0.195
=

hip

hip

inf

3.1.2 Seccin apoyo

P P ev M v
A - I + I = -1.05 MPa
P + P e v' - M v' = -0.11 MPa
s =A
I
I
Las tensiones totales, en MPa, se resumen en el siguiente cuadro.
SECCIN VANO
s
s
CORTO
VACO
-18.60
-3.28
PLAZO
SERVICIO
-23.90
-2.26
LARGO
VACO
-14.76
-4.95
PLAZO
SERVICIO
-16.72
-3.93
s

sup

=-

inf

sup

inf

Los autores, 1998; Edicions UPC, 1998.

SECCIN APOYO
s
s
-7.18
-8.26
-3.78
-9.30
-4.65
-8.94
0.00
-10.97
sup

inf

Hormign armado y pretensado. Ejercicios

132

4 Caso de pretensado excnt rico en fase isosttica

El momento hiperesttico a largo plazo depende del giro inicial y de la fluencia. El primero es
funcin no slo de la rigidez del acueducto y de las cargas de peso propio, sino tambin del
pretensado (P) y de su excentricidad (e). Por otra parte, en la evolucin en el tiempo de ese giro se
debe tener en cuenta la prdida diferida del pretensado. (DP (t, t )).
Giro en los extremos a t = t = 7 das.
dif

q( t

) = 24gEl I - 2PEe lI
3

Sin el efecto hiperesttico, el incremento de giro por fluencia, teniendo en cuenta DP (t, t ) sera:
DP ( t, t ) e l
Dq ( t ) = q( t ) j( t, t ) +
2(E I) [1 + c(t, t ) j(t, t )]
dif

dif

to

A partir del instante de continuidad (t = t ) este incremento valdra


Dq ( t, t ) = Dq ( t, t ) - Dq ( t , t )
1

donde Dq(t ,t ) es el giro producido desde la transferencia al instante de continuidad adicional, cuyo
valor es:
DP( t , t ) e l
Dq ( t , t ) = q( t ) j( t , t ) +
2(E I) [1 + c(t , t ) j(t , t )]
1

to

Con ello se tendra


Dqj (t ) = q (t ) [j (t, t ) - j (t , t )] +
e l [DP(t, t ) (1 + c (t, t )) j (t, t ) - DP(t , t ) (1 + c (t , t ) j (t , t ))]
+
2E I
o

Llamaremos
a = DP ( t, t ) (1 + c( t, t ) j( t, t ))
b = DP( t , t ) (1 + c( t , t ) j( t , t ))
o

Los autores, 1998; Edicions UPC, 1998.

Anlisis

133

El giro producido en cualquier instante por el momento hiperesttico, que aparece progresivamente
es:
M l [1 + c(t, t ) j(t, t )]
q =
2( E I )
h

Mh

t1

Con lo que igualando Dqj = q , se tiene


Mn

q ( t

2
(
EI
)
=

) (j (t, t ) - j (t , t )) + 2(Ee Il) (a - b )

1 + c (t, t ) j (t, t )
o

to

Sustituyendo valores
(E I) = 5.860 10 kN m ; (E I) = 7.984 10 kN m
j (, t ) = 2.0 ; j (90; 7) = 1.2 ;
j (, 90) = 1.4
c (, t ) = 0.8 ; c (90; 7) = 0.9 ;c (, 90) = 0.85
DP (,t ) = 0.10 P =965 kN ; DP (90, 7) =0.05 P =482.5 kN
a = DP( t, t ) (1 + c( t, t ) j( t, t )) = 965 (1+0.82) = 2509 kN
b = DP( t , t ) (1 + c( t , t ) j( t , t )) = 482.5 (1+0.91.2) = 1003.6 kN
a - b = 1505.4
9650 25
q( t ) = 3.36 10 2 5.86 10 e = (3.63 - 20.59 e) 10 rad
25 e
7.984 10 [3.63 - 20.585 e] 10 ( 2 - 1.2 ) + 2 5.86 10 1548.8
2
M = 25
1 + 0.85 1.4
M = 233.32(3.63 - 20.59e) + 936.55e = 846.95 - 3867.51e
6

to

t1

-3

-3

-3

La tabla adjunta representa el valor de M en funcin de e.


e (m)
0 0.025 0.05 0.075 0.1 0.125 0.15 0.171
M (Knm) 847 750
654
557 460 364
267
186
Se observa que M vara linealmente con e. Por otra parte, disponiendo el pretensado con una
excentricidad e = 0.171, igual al lmite inferior del ncleo central, la redistribucin sera mucho
ms pequea pues el giro al transferir sera mucho menor al estar compensando parte del peso
propio.
Para e = 0, se observa que la expresin anterior conduce al valor M =847 kNm que es el obtenido
en el apartado 1).
h

Los autores, 1998; Edicions UPC, 1998.

135

Anlisis seccional

Ejercicio I-13 Diagrama M-C de secciones de hormign armado


Considrense las secciones de hormign armado de la figura adjunta, sometidas a flexin simple.
El hormign es HA-30/6/20/IIa y las armaduras son barras de acero B 500 S.

Se pide:
1. Para la viga rectangular:
1.1. Obtener el diagrama momento-curvatura de forma simplificada en los casos siguientes:

f
f

As = 5 16

As = 0

As = 5 16

As = 3 16

1.2. Para un momento M = 3Mfis, siendo Mfis el momento de fisuracin, calcular el estado de
tensiones en homign y acero en ambos casos.
2. Para la viga en T:
2.1 Calcular la relacin que debe existir entre la cuanta de armadura de traccin y la profundidad
de la cabeza de compresiones, de forma que en servicio la fibra neutra caiga en la cabeza
comprimida.

2.2. Para el caso As = 4 20, obtener el estado de tensiones en el hormign y el acero para M =
150 kNm

Solucin
Caractersticas de los materiales:

Los autores, 1998; Edicions UPC, 1998.

136

Hormign armado y pretensado. Ejercicios

Hormign:
- resistencia caracterstica a compresin: fck = 30 MPa

(fcd = 30/1.5 = 20 MPa)

- resistencia media a compresin: fcm = fck + 8 = 38 MPa


2/3

- resistencia a traccin pura: fct,k = 0.21fcvk

= 2.0 MPa
1/3

- mdulo de deformacin longitudinal: Ej = 8500fcm

= 28577 MPa

Acero:
- resistencia caracterstica: fyk = 500 MPa

(fyd = 500/1.15 = 434.78 MPa)

- mdulo de deformacin longitudinal: Es = 210000 MPa


Caractersticas de la seccin:

A = 500 300 = 150000 mm

Seccin bruta:
1
I = 500 300 = 3125 10
12

rea de acero:

mm

As = 5201 = 1005 mm

As = 3201 = 603 mm
Canto til:

(caso b)

d = 450 mm
d = 50 mm
d/d = 0.111

Cuantas geomtricas:

r=
r' =

As

b d
As'

b d

1005

r/r = 0.60
Coeficiente de equivalencia:

300 450
603

300 450

Es
Ec

= 7.44 10 -

= 4.47 10 -

210000
28577

= 7.35

r = 0.0547
r

n = 0.0328

1 Para la viga rectangular


1.1 Obtencin del diagrama mom ento-curvatura en la seccin rectangular
a) caso sin armadura de compresin (As = 0)
2

b) caso con armadura de compresin (As = 603 mm )


Para la obtencin del diagrama momento-curvatura (M-c) se utilizarn las ecuaciones de equilibrio
entre esfuerzos y tensiones, y de compatibilidad, haciendo las siguientes simplificaciones:

Los autores, 1998; Edicions UPC, 1998.

137

Anlisis seccional

1. El diagrama M-c se supondr trilineal, con puntos de quiebro en los correspondientes a la

fisuracin del hormign, plastificacin del acero (si la rotura es dctil) o del hormign (

= -

0.002) si el acero no ha plastificado. As se tendrn tres ramas lineales: I) estado ntegro sin
fisuras, II) estado fisurado, III) estado de prerrotura.
2. En el estado fisurado (II) se desprecia la resistencia a traccin del hormign, y se considera que
el hormign comprimido se encuentra sometido a tensiones moderadas (inferiores a 0.5fck),
adoptando un diagrama tensin-deformacin lineal.
3. El momento plstico y el momento ltimo se obtienen sin coeficiente de seguridad, basndose en
las resistencias caractersticas del acero fyk y hormign fck, adoptando en este ltimo el diagrama
rectangular de tensiones.
4. Se aceptan las hiptesis de adherencia perfecta entre hormign y acero, deformacin plana de las
secciones y equilibrio entre esfuerzos y resultantes de tensiones en hormign y acero.
Estado I: seccin sin fisurar
En este estado son vlidos los principios de la resistencia de materiales, debiendo para ello obtener
las caractersticas de la seccin homogeneizada:
rea:

Ah = Ab + (n-1)(As+As)

Centro de gravedad:
Inercia:
Rigidez:

Ab

h
2

Ab

+ (n - 1) (A d + A 'd')
s

+ (n - 1) (A + A
s

v = h - v

'

Ih = Ib + Ab(v - h/2) + (n-1)[As(d-v) +As(v-d) ]


KI = EcIh

Momento de fisuracin. Se obtienen a partir de la ecuacin de las tensiones, para el caso en que
siendo M = Mfis, se produce la tensin mxima de traccin en la fibra ms traccionada (z= v).
Entonces de tiene:

s(z = v') =

M fis

v'

Ih

=f

ct ,k

M fis

Ih

ct ,k

v'

Curvatura de fisuracin:

c fis

M fis
Ec

=
h

f ct ,k
Ec

v'

Aplicando estas expresiones a los casos a) y b) del apartado 1.1 se obtienen los valores de la tabla
adjunta.

Los autores, 1998; Edicions UPC, 1998.

138

Hormign armado y pretensado. Ejercicios

Caso a) As = 1005 mm
Parmetros

Caso b) As = 1005 mm
2

As = 0

As = 603 mm

rea homogeneizada
Centro de gravedad

156382 mm

160211 mm

v = 258.2 mm

v = 253.2 mm

v = -241.8 mm

v = -246.8 mm

Inercia homogeneizada

337010 mm

Rigidez

96305 kNm

Momento de fisuracin

27.87 kNm
-4

Curvatura de fisuracin

2.89410

353210 mm

100934 kNm
28.62 kNm

-1

-4

2.83610

-1

Estado II: fase fisurada


Se plantean las ecuaciones de equilibrio y compatibilidad a nivel seccin.

s c b x d - +
2
3

e
e
e'
=
=
x
d -x
x - d'

1
2

s b x + A 's '-A s
c

s s'(d - d' )

As '

Teniendo en cuenta las relaciones tensin-deformacin de los materiales en estado de servicio:

s
s

e
e

= Ec

= Es

se pueden expresar las ecuaciones de compatibilidad en funcin de las tensiones:

s = n s

s '= n s

-x
x

- d'
x

Sustituyendo estas ltimas en las ecuaciones de equilibrio se resuelve el sistema, conduciendo a la


siguiente solucin:

Los autores, 1998; Edicions UPC, 1998.

139

Anlisis seccional

r' d'

2 1 +
r d

r'

x = n r d 1 +
r - 1 + 1 +

r'
n r 1 +

x = n r d -1 + 1 +

n r

(As

=/ 0)

(As=0)

donde se observa que x es independiente del momento aplicado.

= E A (d - x ) d - + A '(x - d') - d'


3

= E A (d - x ) d -
3

K II

K II

(As

(As=0)

s =

(As

x
x - d'

b x d - + n A '
(d - d')
3
x
2

2M
(A =0)
s =
x

b x d
3

=/ 0)

=/ 0)

A partir de

se obtienen

s mediante las ecuaciones de compatibilidad anteriores.


s

Para buscar el inicio de la rama de prerrotura, esto es, el momento y la curvatura plsticas, se busca
la deformacin del hormign para

e =e = f
s

yd

Es

= 434.78

210000 =0.00207. Sabiendo que x no

depende del momento flector en esta fase:

e =e
c

x
d

= Ec

-x

= 0.00207

126.2
450

- 126.2

= 0.0008

= 23.1 MPa < fc k

Como resulta ser que

< fc k, el acero plastifica antes de hacerlo el hormign, siendo la rotura

claramente dctil. El momento de plastificacin se corresponder entonces con aquel para el cual:

s = n s
s

-x
x

= fyd = n

Mp

x
x - d'

b x d - + n A '
(d - d')
2
3
x

d - + n A '(x - d') (d - d')


3

Mp

b x

(
)
n d-x
2
f yd

Los autores, 1998; Edicions UPC, 1998.

-x
x

140

Hormign armado y pretensado. Ejercicios

Aplicando las expresiones anteriores a los casos a y b, se obtienen los resultados de la tabla adjunta,

r = 0.0547 y r/r = 0.60.

siendo n

Caso a) As=0

Parmetro en estado II
x

126.2 mm

Rigidez KII

27877 kNm

Mplstico

178.0 kNm

Curvatura plstica Mp/KII

63.910

Caso b) As=603 mm
119.3 mm

-4

28542 kNm
178.6 kNm

-1

-4

62.6 10

-1

Estado III
Haciendo la hiptesis de rotura en el dominio 3 de deformacin, se tiene:

0 = 0.85fcdby + Asfyd - Asfyd

Mu = 0.85fcdb y

De la primera ecuacin se despeja:

As

f - A f
0.85 f b
'

yd

yd

cd

x = 1.25y
En el caso a: As=0

1005 434.78

0.85 20 300

= 85.7

mm

x = 1.2585.7 = 107.1 mm
Dado que xlim

Mu

cu

0.625d = 281.3 mm, la hiptesis es cierta.

85.7

= 0.85 20 300 85.7 4.50 = 178.0 kN m


2

e
0.0035
=
=
= 327 10 - m -

K III

0.1071

Mu
cu

-M
0
-c
p

En el caso b: As=603 mm , la profundidad y vale

Los autores, 1998; Edicions UPC, 1998.

d -
2

+ Asfyd(d-d)

141

Anlisis seccional

- 603 434.78
= 34.3
0.85 20 300

1005 434.78

mm

x = 1.2534.3 = 42.8 mm
que tambin satisface x < xlim = 0.625d = 281.3 mm; por lo tanto es vlida la hiptesis de rotura
dctil.
Mu

cu

34.3

= 0.85 20 300 34.3 4.50 + 603 434.78( 450 - 50) = 180.6 kN m


2

e
0.0035
=
=
= 818 10 - m -

K III

0.0428

Mu
cu

-M
= 26.5
-c
p

kN m

1.2 Para un momento M = 3Mf i s , el estado de tensiones y deformaciones es:

<

En ambos casos 3 Mfis Mpltico, por tanto nos encontramos en el estado II:
Caso a: As=0
x = 126.2 mm
Mfis = 27.87 kNm
2 3 27.87 10

= 10.83 MPa
=
x
126.2

b x d 300

126
.
2

450

3
3

d-x
450 - 126.2
s = n s
= 7.35 10.83
= 204.24 MPa

s =

2 M

126.2

Caso b: As=603 mm
x = 119.3 mm
Mfis = 28.62 kNm

Los autores, 1998; Edicions UPC, 1998.

142

Hormign armado y pretensado. Ejercicios

s =

=
x
x - d'

d - + n A '
( d - d' )
2
3
x

3 28.62 10
300 119.3
119.3
119.3 - 50
450 ( 450 - 50 )
+ 7.35 603
2
3
119.3

s = 10.26 MPa
d-x
450 - 119.3
s = n s
= 7.35 10.26
= 209.04 MPa
c

b x

s '= n s
s

- d'
x

119.3

= 7.35 10.26

119.3

- 50

119.3

= 43.81

MPa

2 Para la viga en T
2.1 Relacin entre la cuanta de armadura de traccin y la profundidad de la cabeza de
compresiones
Para que la fibra neutra caiga justo en la cabeza de compresin debe cumplirse que x = hf. Como la
cabeza es rectangular, entonces es vlida la expresin para seccin rectangular con b = bf,

ht

es decir,

= n r d - 1 +

con

r=

n r

= hf

As
bf

d
hf

rd

+1 =

2
n

Elevando al cuadrado y operando queda que para


x

h.

n r (h f d ) 2 (1 - h f d )

Los autores, 1998; Edicions UPC, 1998.

se cumple que

143

Anlisis seccional

2.2 Estado de tensiones en el hor mign y el acero en el caso As=4 20 y M=150 kN.m
2

Si bf = 700 mm y As = 4314.2 = 1257 mm :

r=

As
bf

1256

700 450

= 0.004

r = 7.350.004 = 0.0294

y llamamos,

l=

a=
a

hf
d

(1 - a )

100
450

= 0.222
0.04938

(1 - 0.222 )

Se cumple el criterio para que x

= 0.04938

= 0.317 > n r

h ; con lo cual son vlidas las frmulas para seccin rectangular:


f

2
= 0.0294 450 - 1 + 1 + 2 = 96.7
= n r d - 1 + 1 +

n r
0.0294

2M
2 150 10
s =
=
= 10.61 MPa
x
96.7

b x d 700 96.7 450


3
3

d-x
450 - 96.7
s = n s
= 7.35 10.61
= 284.92 MPa
x

96.7

Los autores, 1998; Edicions UPC, 1998.

mm

145

Anlisis seccional

Ejercicio I-14 Diagrama M-C de secciones de hormign pretensado con adherencia

Una viga tipo prefabricada de hormign pretensado para un forjado de un aparcamiento tiene una
seccin en pi, como indica la figura adjunta.
Caractersticas de la seccin homogeneizada:

Ah = 0.2434 m2
Ih = 0.0112 m4
vh = 0.23 m
v'h = -0.47 m
eh = -0.20 m
Ap = 560 mm2

La viga va pretensada de extremo a extremo con dos cordones de f0.6" en cada alma, de forma que
la excentricidad de la resultante es de 0.20 m respecto del centro de gravedad de la seccin. El
acero es Y 1860 S7 (fpu = 1860 MPa, fpy = 1700 MPa), tesado a 1400 MPa. El pretensado se
transfiere a la viga a los 5 das despus del hormigonado. La longitud de la viga es de 14 m.
Inmediatamente despus de la transferencia se somete la viga a un ensayo de flexin bajo caga
creciente hasta rotura.

Se pide:

1. Obtener el diagrama momento-curvatura de la seccin central y predecir la carga de fisuracin y


de rotura por flexin.
2. Para una carga de 60 kN, calcular el estado de tensiones en el hormign y en la armadura activa,
as como la profundidad de la fibra neutra y la rigidez EI de la seccin.

Los autores, 1998; Edicions UPC, 1998.

146

Hormign armado y pretensado. Ejercicios

Solucin

Caractersticas de los materiales:


- resistencia a compresin del hormign a los 28 das:
fck = 45 MPa
- resistencia a compresin del hormign a los 5 das:
fc,5 = 0.525fck = 23.63 MPa
- resistencia media a compresin del hormign:
fcm = fck + 8 MPa = 53 MPa
- resistencia caracterstica a traccin del hormign a los 28 das:
fct,k= 0.21fck2/3 = 2.66 MPa
- resistencia a traccin del hormign a los 5 das:
fct,5 = 0.55fct,k = 1.46 MPa
- mdulo de deformacin longitudinal del hormign a 28 das:
Ec,28= 8500 fcm, 281/3=31928 MPa
- mdulo de deformacin longitudinal del hormign a 5 das:
Ec,5 = b5Ec,28 = 22829 MPa
(b5 = 0.715)
- mdulo de deformacin longitudinal del acero:
Ep = 1.9105 MPa
- coeficiente de equivalencia a los 5 das:
n = Ep/Ec = 8.3
- rea de las armaduras activas:
Ap = 4140 = 560 mm2
- radio de giro de la seccin homogeneizada:
r2 = Ih/Ah = 46014.8 mm2
- resistencia de clculo del hormign:
fcd = fcd /1.5 = 30 MPa
- resistencia de clculo del acero activo:
fpyd = fpyk /1.15 = 1478 MPa
- fuerza de pretensado a los 5 das.
- fuerza de pretensado antes de transferir:
P0 = Apsp0 = 560 mm21400 MPa = 784 kN
- prdidas por acortamiento elstico:
A E
DP3 = s cp p p = -3.36 560 8.3 = -15617 N
E c5
siendo:

s =cp

P0
A

= -3.36

P0 e 2
I

MPa

M pp e
I

=-

784000
243400

784000 (- 200 )

112 10

1.491 10 8

Los autores, 1998; Edicions UPC, 1998.

(- 200 )

112 10 8

147

Anlisis seccional

Mg

(25 0.2434 ) 14 = 149.1


2

kN m

- fuerza de pretensado despus de la transferir: Pk5 = P0 + DP3 = 784-15.6 = 768.4 kN

1 El diagrama momento-cur vatura de la seccin central pedido tendr la siguiente


forma

La existencia de un pretensado provoca la aparicin de una curvatura inicial en la seccin, que ha de


tenerse en cuenta a la hora de determinar la curvatura total, que es debida tanto al pretensado como
al momento exterior.

Por lo tanto, a la hora de calcular la curvatura total en la seccin se considerar:


Mtotal = Mext + Pe
M total
M +Pe
c=
= ext
K
K

M ext
K

Pe
K

=c

ext

+c

Estado I: fase sin fisurar

Los autores, 1998; Edicions UPC, 1998.

148

Hormign armado y pretensado. Ejercicios

Rigidez elstica: Ec,5Ih = 22829112108 = 3.01014 Nmm2 = 255685 kNm2


Momento de pretensado: Pe = 768.4(-0.20) = -153.68 kNm
-153.68
Pe
c0 =
=
= -6.011 10 - 4 m -1
E c,5 I h
255685
Momento debido al peso propio: Mg = 149.1 kNm
Al transferir la totalidad de la carga de pretensado, el momento del pretensado Pk,5e es superior al
del peso propio. Se crea, pues, una contraflecha y el momento total aplicado es entonces M = Pk,5e
+ Mg = -4.58 kNm.
Teniendo en cuenta que la rigidez elstica es Ec,5Ih = 255685 kNm2, la curvatura al transferir es
Mg + P e
- 4.58
cg =
=
= -1.791 10 - 5 m -1 .
Ec Ih
255685
El momento de fisuracin ser aquel que, junto al pretensado, produzca una tensin en la fibra
inferior igual a la resistencia caracterstica a traccin del hormign:

s(v') = Mfis

=-

Pk ,5
Ah

fct,k I h
v'

Pk,5 e
Ih

v'-

Mfis
Ih

v' = f

ct ,5

= 1.46 MPa

1.46 112 10
46014.8

- 768400
- 200
- P
+ e = 470
470
v
'

Mfis = 263.7 kNm


La curvatura de fisuracin ser:
c fis

+ P e 263.7 - 153.68
=
= 4.30 10 - m E I
255685

M fis

El incremento de curvatura bajo el momento exterior es

Dc = c - c = 4.47 10 - m 4

fis

263.7

153.68

Los autores, 1998; Edicions UPC, 1998.

149

Anlisis seccional

Punto A: situacin en vaco (peso propio+pretensado al transferir). Mext = Mg = 149.1 kNm


Punto B: estado de curvatura nula. Mext = Pe = 153.68 kNm
Punto C: fisuracin. Mext = 263.7 kNm
Estado II: fase fisurada
Se admite un diagrama lineal del hormign en compresin y resistencia nula a traccin. En este
estado se tienen las siguientes ecuaciones de equilibrio y compatibilidad:
Pn = C ApDsp
M = Czc

De
d -x
Ds = n s
d -x
x
p

Las incgnitas de estas 3 ecuaciones son sc, x y Dsp. Dado que el esfuerzo axil Pn no es nulo, no es
posible obtener x independientemente de M, de forma que la rigidez de la fase fisurada no es
constante, sino que vara con el momento aplicado.
Para resolver el problema se procede de la siguiente forma.
La compresin C valdr, suponiendo x > hf:

C = C1 + C2 +C3

x - hf

s c1 = s c x
s c1
=

x
x - hf
s - s = s h f
c1
c
c
x

sc

Sustituyendo se tiene:

Los autores, 1998; Edicions UPC, 1998.

C1 = bfhfsc1
C2 = 0.5bfhf(sc-sc1)
C3 = 0.5bw(x hf)sc1

150

Hormign armado y pretensado. Ejercicios

1
2

b h (2 x - h ) + b (x - h

El momento respecto de la armadura traccionada vale:


M = C1z1 + C2z2 + C3z3
x - hf
h
h
donde z1 = dp - f ; z2 = dp - f ; z3 = dp hf 2
3
3

h
h b h

d -
b h (x - h ) d - +
3
2
2
s

M=

x
+ b (x - h ) d - h - x - h

2
3

Entonces, teniendo en cuenta que

Ds = n s
p

dp

1
2

Se puede despejar
expresiones:

1
2

b h (2 x - h ) + b (x - h
f

) ] - A n s (d - x )
2

s /x y sustituir en la ecuacin de momentos, resultando las siguientes


c

Pn

b h (2 x - h ) + b (x - h
f

la ecuacin de equilibrio de fuerzas queda

as:
Pn

-x

) ] - A n (d - x )
2

h b h
h b (x - h )
x-h

(x - h ) d - +
d - +
d - h
2
2
3
2
3

b (x - h )
b h
(2 x - h ) +
- n A (d - x )
2

bf hf
M

=P
n

Esta es una ecuacin polinmica de tercer grado en x que puede resolverse por tanteos, para un
valor del momento M y de la fuerza de neutralizacin Pn. Dicha ecuacin se puede expresar de la
forma f(x) = Ax3 + Bx2 + Cx + D, siendo los coeficientes:
A
B

=
=

bw
6

M
- d
2 P

bw

Los autores, 1998; Edicions UPC, 1998.

151

Anlisis seccional

h (b - b ) + h (b - b ) + n A M
2
P

M
h
h
M
D= (b - b ) - - d
(b - b ) - n A d
3
P
P
2

M
= - d
P

Esta fase en la que la seccin est fisurada se acaba cuando plastifica el hormign (ec = 0.002) o
bien cuando lo hace el acero de la armadura activa ( e pn

pyd

fpyd

Ep

1.15 190000

-x

dp

De = e
p

1700

, con

= 7.780 10 -

e =
c

+ De p e pyd ):

Ec

Al tratarse de armaduras pretesas, la fuerza de neutralizacin se corresponde con la fuerza de


pretensado en bancada; esto es, Pn = P0 = 784 kN. Por lo tanto:

e =
pn

Pn

Ap E p

784000
560 190000

= 7.368 10 -

En la siguiente tabla se recogen los valores de x asociados a diferentes momentos en la fase


fisurada. Tambin se calculan en cada caso las deformaciones en el hormign y en el acero para
determinar en qu momento plastifica la seccin.
Mext (kNm)

X (mm)

De

266

494

2.1110

-2.7410

7.3710

7.3410

c = ec/x (m-1)
4.2810-4

270

466

2.1710-4

-1.6810-5

7.3710-3

7.3510-3

4.6610-4

280

395

2.3410-4

2.0710-5

7.3710-3

7.3910-3

5.9210-4

290

326

2.5510

8.1310

7.3710

-3

7.4510

7.8210-4

300

263

2.8210-4

1.7910-4

7.3710-3

7.5510-3

1.0710-3

310

214

3.1410

3.1710

7.3710

-3

7.6910

1.4710-3

316

192

3.3510-4

4.1510-4

7.3710-3

7.7810-3

1.7410-3

-4

-4

-4

e = De + e

pn

-5

-5

-4

-3

-3

-3

pn

-3

La fase de prerrotura se inicia, pues, para un momento exterior Mp = 316 kNm, bajo la accin del
cual se produce la plastificacin del acero de las armaduras activas, pero no la del hormign (ec =
3.3510-4 < 0.0035).
Al contrario de lo que suceda en el estado no fisurado, se conoce la curvatura de la seccin, pero
no la rigidez de sta. Por lo tanto, se procede de la siguiente forma:
c

M total
K

M ext

+Pe
K

Los autores, 1998; Edicions UPC, 1998.

152

Hormign armado y pretensado. Ejercicios

K II

=E

c,5

fis

M total
c

M ext

+ P e
c

A partir de la rigidez de la seccin en esta fase, y conociendo el mdulo de deformacin


longitudinal del hormign, puede obtenerse la inercia de la seccin fisurada.
En la tabla adjunta se indican las rigideces e inercias fisuradas correspondientes a cada momento
exterior actuante en esta fase.
Mext (kNm)
266

Mtot (kNm)
112.32

KII (kNm2)
262430

Ifis (m4)
0.0115

270

116.32

249614

0.0109

280

126.32

213378

0.0094

290

136.32

174322

0.0076

300

146.32

136748

0.0060

310

156.32

106340

0.0047

316

162.32

93287

0.0041

Estado III: fase de prerrotura


Esta fase puede considerarse prcticamente recta, dado que la armadura ha plastificado, uniendo el
punto de plastificacin con el de rotura por flexin. Este ltimo se obtiene calculando el momento y
la curvatura ltimas as:
Momento ltimo: ecuaciones de equilibrio
Pn = C - DT ;
C = Pn + DT = Dpfpyd
Mu = C . z = Dpfpyd (d-y/2)
1700
Dpfpyd = 560 mm2
N/mm2 = 827.83 kN
1.15
C = 827.83 = 0.85 fcdby
827,83
= 27.05mm < 100 mm
y=
0.85 30 1200
luego la zona comprimida cae en la cabeza superior.
Mu = 827.83 (0.43-0.027/2) = 344.79 kN.m
Clculo de las deformaciones y curvatura ltimas
x = 1.25 y = 33.8 mm
ec = -0.0035
d-x
430 - 33.8
Dep =
ec =
0.0035
d
33.8

= 0.0410

Los autores, 1998; Edicions UPC, 1998.

153

Anlisis seccional

Cu

k III

0.0035

= 0.035m - = 103.5 10 - m 1

x
0.0338
Mu - My

-C

Cu

344.77 - 316
(103.5 - 1.74 ) 10 - 3

= 282.7kN.m

Las capas de fisuracin y rotura son, teniendo en cuenta que M = Pa = 5P, P = M/5:
Pfis

Pu

M fis
5
Mu
5

266.04kN.m
5

344.77kN.m

= 53.21kN

= 68.95kN

Se observa que, a diferencia de lo que pasa en presas de hormign armado, en pretensado la


fisuracin est prxima a la rotura.

2 Estado de tensiones para u na carga de 60 kN

En este caso Pfis < P < Pu . Estaremos por tanto en fase fisurada. M = 5 P = 300 kN. Tomando los
valores de la tabla del apartado 1 se obtiene:
x = 236 mm
Ifis = 0.0060 m4
Ec,5 I=136974 kN.m2

s =
c

1
2

[b

Pn x

Ds = n s
p

h (2x - h ) + b (x - h ) ] - A n (d - x )
2

dp
c

768400 N
p

560 mm 2

-x
x

= 39.58 MPa

- 39.58 = 1332.56 MPa

Los autores, 1998; Edicions UPC, 1998.

= 7.51 MPa

155

Anlisis seccional

Ejercicio I-15 Seccin sometida a traccin pura. Armaduras pretesas

Se proyecta un tirante de hormign pretensado con armaduras pretesas y seccin rectangular, tal
como indica la figura adjunta.

La tensin de las armaduras en bancada, justo antes de transferir, es de 1400 N/mm . La armadura
activa est compuesta de 5 cordones de f 0.6 (A = 5140 = 700 mm ). Se adoptan las
siguientes caractersticas de proyecto de los materiales:
- hormign HP 45/P/20/IIb,
f = 45 N/mm
coeficiente final de fluencia j(7,)= 2.0
retraccin final e = -310
- acero de pretensado Y 1860 S7, f = 1860 N/mm , f = 1700 N/mm
relajacin final r =8%
- armaduras pasivas B 500-S f =500 N/mm
La transferencia se produce a los 7 das e, inmediatamente, se coloca el tirante en carga bajo una
solicitacin permanente de traccin pura de 400 kN.
2

P total

ck,28

-4

cs

pu

yk

py,k

Se pide:

1. Calcular las tensiones en hormign y en las armaduras activas justo despus de transferir, tras
aplicar la fuerza de traccin permanente y a largo plazo.
2. Calcular la sobrecarga de traccin T que habra que aplicar a la pieza para que sta fisure, y la
tensin en el acero justo antes de fisurar.
3. Disponer las armadura pasivas necesarias suponiendo que la sobrecarga mxima prevista es de
500 kN.
q

Los autores, 1998; Edicions UPC, 1998.

156

Hormign armado y pretensado. Ejercicios

Solucin

1 Clculo de tensiones

a) La fuerza de pretensado en bancada antes de transferir es:


P =A
o

s po = 700 mm 2 1400

N / mm = 980000 N = 980 kN
2

y la tensin en el hormign, antes de transferir es s = 0.


Dado que el pretensado se introduce sobre la seccin de hormign con armaduras activas adheridas,
hay que calcular la seccin homogeneizada A . Para ello se calcula el coeficiente de equivalencia
entre hormign y acero de pretensado n= E /E , tomando como material base el hormign.
co

E = 10000 f = 10000 45 + 8 = 37563 N / mm


E = 0.8 E = 30050 N / mm
E = 190000 N/mm
n = 190000
30050 = 6.32
A = A + (n - 1) A = 500 200 + 5.32 700 = 103724 mm
3

c,28
c7

cm

c 28

La tensin y la deformacin en el hormign sern:


P = 980000 = -9.45 N / mm (compresin)
s =A 103724
s
-9.45
e =
E = 30050 = -3.15 10
2

c1

-4

La variacin de tensin en la armadura activa, teniendo en cuenta que hay adherencia entre
hormign y acero (e = De ), ser:
E s = n s = -59.7 N / mm
Ds = E De = E e =
E
c

Po

Este valor corresponde a las prdidas por acortamiento elstico, y representa el 4.3% de la tensin
inicial s = 1400 N/mm .
po

sP1 = s po + DsPo = 1400 - 59.7 = 1340.3

N / mm

b) Tensiones tras aplicar la fuerza de traccin de 400 kN

Los autores, 1998; Edicions UPC, 1998.

157

Anlisis seccional

La fuerza de traccin se aplica tambin sobre la seccin homogeneizada, por tanto:


T = 400000 = 3.86 N / mm
Ds =
A 103724
Ds
De =
E = 1.29 10 = De
Ds = n Ds = 24.4 N / mm
s = s + Ds = -9.45 + 3.86 = -5.59 N / mm (compresin)
s = s + Ds = 1340.3 + 24.37 = 1364.7 N / mm
2

c1

-4

c1

c1

p1

c,7

p1

c1

c2

c1

p2

c1

p1

p1

c) Tensiones a largo plazo


Para ello hay que calcular las prdidas diferidas, segn la ecuacin.
n s j + E e + 0.8 Ds
DP = A
1 + n A A1 + eI (1 + c j )

donde
s = s = -5.59 N / mm
e = -3 10
Ds = - r s = -0.08 1400 = -112 N / mm
e = 0 ; c = 0.8 , j = 2.0
cgp

cs

pr

cgp

c2

-4

cs

pr

DPdif = 700

po

- 6.32 5.59 2 - 190000 3 10 -4 - 0.8 112


= -700 194.9 = -136430 N
.32 700 (1 + 0.8 2 )
1 + 6500
200

La fuerza de pretensado a largo plazo ser:


P = P + DP = 700 - 136430 = 818860 N

Con lo que las tensiones en acero y hormign sern:


s p = 1208
s c = s c1

N / mm
DP
136430
+
A = -5.59 + 103724 = -4.28 N / mm
2

dif

Los autores, 1998; Edicions UPC, 1998.

158

Hormign armado y pretensado. Ejercicios

2 Clculo de la sobrecarga d e traccin que fisura la pieza

Se realizarn dos clculos, uno suponiendo que la sobrecarga acta a corto plazo (7 das), y otro
suponiendo que la sobrecarga acta a largo plazo. En el primer caso la resistencia a traccin es
menor y la fuerza de pretensado es mayor. La evolucin de la resistencia a traccin con la edad
viene dada por la tabla 30.4.b de la Instruccin EHE.
f ct ,28

= 0.21 3

f ck

= 2.66

N / mm

A los 7 das, f = 0.70 f


A largo plazo, f = 1.10 f
ct ,7

ct ,28

ct ,

= 1.86

ct ,28

N / mm
= 2.93 N / mm
2

La fuerza de traccin que fisura la pieza ser aquella que produzca tensiones de traccin tales que
superpuestas a las ocupadas en estado permanente, superen la resistencia a traccin, es decir:
T
s +
A =f
cr

cgp

ct

donde s es la tensin debida a cargas permanentes. Si se plantea a corto plazo, s =s =-5.59


n/mm y si se plantea a largo plazo s =s = -4.28 N/mm
T = (f - s ) A = (1.86 + 5.59) 103724 = 772744 N
T = (f - s ) A = (2.93 + 4.28) 103724 = 747850 N
cgp

cgp

cgp

cr,7

ct ,7

cr,

ct ,

cgp

c2

Por tanto, se adopta T = 767850 N.


cr

3 La sobrecarga mxima pr evista es Tk= 500 kN que es menor que la carga de


fisuracin, por tanto, en servicio no se superar el estado lmite de aparicin de
fisuras

La tensin del acero justo antes de fisurar ser:


s = s + nDs
p

p1

400000 + 747850 = 11.07 N / mm


A
= 1340.3 + 6.32 11.07 = 1410.26 N / mm

Ds c =
sp

Sin embargo, hay que disponer armadura pasiva mnima longitudinal y transversal, segn los
siguientes criterios:

Los autores, 1998; Edicions UPC, 1998.

159

Anlisis seccional

a) Rotura bajo carga mxima


T = 1.35 400 + 1.50 500 = 1290 kN
T A f + A f
A f = 700 1700
1.15 = 1034782 N = 1034.8 kN
A f = T - A f = 1290 - 1034.8 = 255.2 kN
1.15
= 587 mm
A = 255500
d
d

pyd

yd

p pyd

s yd

p pyd

b) Rotura frgil al fisurar


A f
p

*
pyd

+ A s f yd A c f ct = 100000 2.66 = 266000

es la resistencia residual de la armadura de pretensado desde la tensin antes de fisurar


=1410.3 N/mm a la plastificacin f = 1700
1.15 = 1478.3

*
f pyd

spfis

ypyd

f = 1478.3 - 1410.3 = 68
A f = 266000 - 700 68 = 218400 N
A 502.3 mm
*
pyd

s yd
s

Por tanto adoptamos el valor anterior, A =587 mm disponiendo 6f12 mm., segn indica la figura:
s

Los autores, 1998; Edicions UPC, 1998.

161

Anlisis seccional

Ejercicio I-16 Efectos trmicos a nivel seccin

Un puente losa de hormign pretensado con armaduras postesas, cuya geometra y trazado de los
tendones se muestra en la figura adjunta, est sometido a las siguientes cargas:
- cargas permanentes: peso propio = 225 kN/ml
cargas muertas = 68 kN/ml
- cargas de trfico:
sobrecarga uniforme = 4.0 kN/m
carga puntual mvil de 600 kN
Se considera adems la accin trmica ambiental, definida por una distribucin de temperaturas en
el canto de la seccin que sigue una ley parablica de segundo grado, segn se indica en la figura
adjunta, actuante por igual en toda la longitud del puente.
El tesado se realiza desde ambos anclajes a la vez. Las prdidas instantneas de pretensado son,
aproximadamente, las siguientes: DP = 0.35 x (porcentaje), siendo x la distancia al anclaje. El
porcentaje de prdidas diferidas de pretensado se considera igual en todas las secciones: DP = 20
%. Se supone que el momento hiperesttico de pretensado en el vano central es M = 0.25 Ph.
El hormign es HP-40/P/20/IIb y se considera un coeficiente de dilatacin a = 10 C .
2

ins

dif

hp

-5

A=9m

I = 2.91 m

v = 0.80 m

-1

v = -0.80 m

Se pide:

1. Obtener las tensiones debidas a la accin trmica en las secciones de apoyos y centro de vanos.

Los autores, 1998; Edicions UPC, 1998.

162

Hormign armado y pretensado. Ejercicios

2. Estimar el valor de la fuerza de pretensado en anclajes necesaria para garantizar que bajo las
cargas permanentes no se supera el estado lmite de descompresin, y que bajo las cargas
permanentes ms la accin trmica no se supera el estado lmite de aparicin de fisuras.
Solucin

1. La ley de temperaturas y deformaciones asociadas a ella, se rigen por las siguientes expresiones:
Dt(z) = 4.6875z

+ 7.5z +11
= aDt = 10 (4.6875z + 7.5z +11)
2

De

-5

Asimismo, se considera como valor del mdulo de deformacin longitudinal del hormign E =
10000f = 36342.41 MPa.
Formulando el anlisis seccional frente a deformaciones impuestas de forma matricial, se plantea el
siguiente sistema de ecuaciones:
DN EA 0 De DN

DM = 0 EI Dc +


DM
c

1/3

cm,j

donde:

De es la deformacin de la fibra baricntrica


Dc es la curvatura seccional
m

EA es la rigidez axial
EI es la rigidez a flexin
(DN, DM) son los esfuerzos exteriores actuantes
(DN , DM ) son los esfuerzos asociados a las deformaciones impuestas, cuyo valor se obtiene
ms adelante.
No se consideran esfuerzos exteriores actuantes. Por lo tanto, el vector correspondiente (DN, DM)
es nulo.
El sistema de referencia se sita en el centro de gravedad de la seccin, por lo que son nulos los
trminos no diagonales. Los trminos de la diagonal se corresponden a la seccin de hormign:
EA = E A = 327081690 kN
EI = E I = 105756413.1 kNm
0

Los autores, 1998; Edicions UPC, 1998.

163

Anlisis seccional

El vector (DN , DM ) tiene como componentes:


0

DN = - E De dA =
0

+
(

DN = -40800.03 kN
0.5

- 0.5

10

-5

4.6875 z

-E {
c

(4.6875 z + 7.5 z + 11) 10 dz +

-0.5
-5
10

- 0.8

+ 7.5 z + 11) 3 dz +

0.8

0.5

10

-5

(4.6875 z + 7.5 z + 11) 10 dz }


2

DM = E De z dA =
0

E {
c

-0.5
-5
10

- 0.8

(4.6875 z + 7.5 z + 11) z 10 dz +


2

+
(
+
+ ) +
(
DM = 7713.68 kNm
El sistema de ecuaciones as planteado tiene como solucin:
DN
De = E A = 1.247 10
DM
Dc = E I = -7.294 10
0.5

- 0.5

10

-5

4.6875 z

7.5 z

11

z 3 dz

0.8

0.5

10

-5

4.6875 z

+ 7.5 z + 11) z 10 dz }

-4

-5

La ley de deformaciones totales es:


De(z) = De - Dcz = 1.24710 + 7.29410 z
La ley de deformaciones mecnicas se obtiene restando la deformacin no mecnica (en este caso
debida a la temperatura) a la deformacin total:
De (z) = De(z) - De (z) = 10 (1.47 - 0.236z - 4.6875z )
-4

-5

-5

De 0
Dem
De

Las tensiones en el hormign se obtienen a partir de las deformaciones mecnicas como:


Ds = De (z)E = -1703.55z -85.77z +534.23
donde introduciendo z en metros, se obtiene la variacin de tensin Ds en kN/m . Estas tensiones
son autoequilibradas y no dependen de las vinculaciones del elemento, sino nicamente de las
caractersticas seccionales y de la distribucin de temperaturas en la seccin. Sin embargo, dado que
c

Los autores, 1998; Edicions UPC, 1998.

164

Hormign armado y pretensado. Ejercicios

se trata de una estructura hiperesttica, la curvatura inducida por la temperatura provoca unos
esfuerzos hiperestticos, que tendrn la distribucin siguiente:

Teniendo en cuenta que una ley de curvaturas constante provoca un giro en un extremo de valor:
cl
J = J + c( x ) dx =
2
B

Se plantea la compatibilidad de giros en la seccin de apoyo, considerando adems que, por simetra
de acciones, geometra y vinculaciones, el momento hiperesttico en C es igual al momento
hiperesttico en B.

l M l M l
M l
2 + 3EI = c 2 - 3EI - 6EI
25 + M 25 = c 35 - M 35 - M 35
-c
2 3EI 6EI
2 3EI
M = 1.161DcEI = 7713.87 kNm
Las tensiones (en kN/m introduciendo z en metros) que provoca este momento en el vano central
son:
7713.87 kN m z = -2650.81 z kN m
M
s = - z = I
2.91 m
-c

AB

HT

AB

BC

HT

HT

HT

BC

HT

BC

HT

HT

Las tensiones totales debidas a la accin trmica en el vano central sern suma de la parte isosttica
y de la hiperesttica:
s (z) = -1703.55z 2736.58z + 534.23
expresadas en kN/m cuando z se da en metros.
2

Los autores, 1998; Edicions UPC, 1998.

165

Anlisis seccional

-2745.31 kN/m2=-2.75 MPa

534.23 kN/m =0.53 MPa

1633.22 kN/m =1.63 MPa

2. Las acciones que se consideran a la hora de verificar las condiciones de fisuracin del enunciado
son:
- cargas permanentes: peso propio: 225 kN/m
cargas muertas: 68 kN/m
- pretensado:
P = P (1-0.35x)
P = P (1-0.35x-0.2)
M = 0.25P h = 0.4P
- temperatura
Se consideran las secciones crticas de apoyo interior y centro de luz del vano intermedio. Las
tensiones se calculan como:
M
g P
g P e
g M
s( z ) = zz- z+s
A
I
I
I
a) Estado lmite de descompresin
Para que se verifique este estado lmite de servicio se ha de imponer que las tensiones en el
hormign sean siempre de compresin (negativas segn el convenio de signos).
La situacin psima en la seccin de apoyo se da en la fibra superior; mientras que en la seccin de
centro de vano, la inferior es la fibra que determina la fuerza de pretensado necesaria.
Seccin de apoyo.
ki

kd

hip

HT

temp

e = 0.8 - 0.15 = 0.65 m


x = 25 m P = 0.713P
M = 0.25P h = 0.285P
z = v = 0.8 m
M = -0.151g25 = -27651.88 kNm
kd

hip,d

kd

Los autores, 1998; Edicions UPC, 1998.

166

Hormign armado y pretensado. Ejercicios

0.9 0.712 P - 0.9 0.712 P 0.65 0.8 - 0.9 0.285 P 0.8 - -27651.88 0.8 0
9
2.91
2.91
2.91
P 29670 kN
Seccin de vano.
-

e = -0.65 m
x = 42.5 m P = 0.651P
M = 0.25P h = 0.261P
z = v = -0.8 m
M = 0.094g25 = 17213.75 kNm
kd

hip,d

kd

0.9 0.651 P - 0.9 0.651 P (-0.65) (-0.8) - 1.1 0.261 P (-0.8) - 17213.75 (-0.8) 0
9
2.91
2.91
2.91
P 52078.25 kN
Por tanto, se necesita en anclajes una fuerza P = 52078 kN para satisfacer el estado lmite de
descompresin, sin efecto trmico.
b) Estado lmite de apertura de fisuras
La fuerza de pretensado necesaria se obtiene imponiendo que en ninguna fibra del hormign se
supere la resistencia a traccin de ste. El valor que se adopta para la resistencia caracterstica a
traccin del hormign es:
f = 0.21f = 2.46 MPa = 2456.2 kN/m
Seccin de apoyo
En la seccin de apoyo la temperatura provoca tensiones de compresin en la fibra superior. Como
adems se permite que las tensiones en esta fibra sean superiores (f ), es determinante el estado
lmite de descompresin, visto anteriormente.
Seccin de vano
En este caso la inecuacin que se ha de resolver se obtiene de imponer que en la fibra inferior las
tensiones no superen la resistencia a traccin del hormign:
-

ancl

2/3
ck,j

ct,k

ct,k

2456

0.9

0.651 P0
9

1.1 0.261 P0
2.91

( - 0 .8 ) -

0.9

0.651 P0 ( -0.65 )
2.91

17213 .75
2.91

( -0.8) -

( -0.8) + 1633 .22

P 43023.69 kN
0

Los autores, 1998; Edicions UPC, 1998.

167

Anlisis seccional

Por lo tanto, la situacin determinante se da en la seccin central del vano interior a la hora de
verificar el estado lmite de descompresin bajo cargas permanentes. La fuerza de pretensado en
anclajes as determinada ha de ser:
P 529078 kN
0

Los autores, 1998; Edicions UPC, 1998.

169

Curado

Ejercicio I-17 Curado de estructuras de hormign


Recin salido de la Escuela le ponen al frente de los aspectos tcnicos de ejecucin de una obra de
edificacin situada en primera lnea de mar (adjunto jefe de produccin), requirindole que
determine los tiempos de curado segn la EHE-98, en las siguientes condiciones:
1. Hormigonado en verano y empleo de un cemento tipo CEM I 42,5 R.
2. Suponiendo que se produjera un retraso por causas ajenas al director de obra (evidentemente!),
y se tuviese que hormigonar el tajo en enero del siguiente ao, determinar el tiempo de curado
requerido en esta situacin y comparar con la anterior.
3. Durante ese perodo, y dado que vd. se ha convertido en un especialista, su director del
grupo de obras, le pide que determine para el mes de enero el tiempo de curado, de una obra
relativamente prxima, si bien situada al interior (no costa).
4. Por ltimo, considerando que en la obra del apartado 3 corresponde a un pavimento con un
cemento tipo CEM IV, se le pide calcular el nuevo tiempo de curado y hacer una comparacin
de los resultados obtenidos en las soluciones anteriores.

Solucin
En primer lugar se propone hacer un curado mediante riego con agua, lo cual responde de forma
satisfactoria a los problemas planteados. Para la determinacin del tiempo de curado mediante agua,
la EHE-98 propone la siguiente expresin:
D = K * L * D 0 + D1
donde:
D. la duracin mnima, en das, del curado
K. coeficiente de ponderacin ambiental, de acuerdo con la tabla 74.4
L. coeficiente de ponderacin trmica, de acuerdo con la tabla 74.5
D0. parmetro bsico de curado, segn la tabla 74.1
D1. parmetro bsico del tipo de cemento, segn la tabla 74.3
En la tabla adjunta se muestran los valores considerados de estos coeficientes, as como el resultado
obtenido de la duracin en los cuatro casos analizados.

Los autores, 1998; Edicions UPC, 1998.

170

Hormign armado y pretensado. Ejercicios

Valores

Caso 1

Caso 2

Caso 3

Caso 4

Tipo III

Tipo III

Tipo II

Tipo II

K= 1,15

K= 1,15

K= 1,00

K= 1,00

1,3

1,3

1,3

D0

D1

3.5

4.5

3.9

5.9

D (en das)

En la determinacin del valor de D0, se ha considerado que las velocidades de desarrollo de la


resistencia del hormign es rpida o media en funcin del caso, aunque al variar las condiciones
ambientales de exposicin durante el curado, conduzcan a un mismo valor de D0 en los cuatro
casos. Los valores de los das de curado mnimos se sitan entre 4,5 y 5,9 das, lo cual debe
tomarse en consideracin, debido a la gran repercusin que tiene sobre las caractersticas de
proteccin de la piel del hormign.
Como puede apreciarse, los coeficientes incluidos en la expresin pueden agruparse en tres tipos de
factores:
- caractersticas del conglomerante y de la dosificacin (relacin agua / cemento);
- condiciones ambientales durante el curado;
- caractersticas de agresividad ambiental durante la vida de la estructura.
Ello, lgicamente, conduce a diversas combinaciones que dan como resultado un abanico amplio de
opciones, tal como se pone de manifiesto en los resultados obtenidos en los cuatro casos analizados.

Los autores, 1998; Edicions UPC, 1998.

Estados lmites ltimos

171

BLOQUE II Estados lmites ltimos

Los autores, 1998; Edicions UPC, 1998.

173

E.L.U. agotamiento por solicitaciones normales

Ejercicio II-1 Influencia de las cuantas y el axil en el comportamiento en E.L.U.


de secciones rectangulares

Considrese una seccin rectangular de hormign armado sometida a flexocompresin recta, cuya
geometra, armaduras y caractersticas de los materiales se indican en la figura adjunta. Se utilizar
el mtodo del diagrama rectangular para clculo en rotura de la seccin, as como los valores
medios de los coeficientes de minoracin de las resistencias de los materiales, se supondr un
control de calidad intenso,
f = 30 MPa
f = 500 MPa
A = 18.85 cm
A = 6.0 cm
h = 0.50 m
d = 0.45 m
d= 0.05 m
ck

yk

Se pide:

1. Obtener una expresin adimensional que permita determinar la profundidad relativa de la fibra
neutra x/d en rotura, en el supuesto de que el hormign est en agotamiento y las armaduras de
traccin y compresin hayan plastificado (rotura en el dominio 3). Obtener x/d para el caso
especfico de la seccin de la figura sometida a flexin pura.
2. Obtener la relacin entre las cuantas mecnicas de armaduras de traccin y compresin para que
la rotura sea crtica.
3. Obtener el esfuerzo axil de compresin adimensional n que, actuando sobre la seccin armada
de la figura, dara lugar a una rotura crtica.
4. Dimensionar las armaduras de traccin y de compresin necesarias para resistir un momento
flector de 380 kN.m de forma que la profundidad de la fibra neutra en rotura sea a) x=x , b)
x=0.45d, c) x=0.30d. Obtener la cuanta total de armadura en los tres casos, incluyendo, en su
caso, la de montaje (mnimo 2 f 12).
crit

lim

Los autores, 1998; Edicions UPC, 1998.

174

Hormign armado y pretensado. Ejercicios

5. Para las cuantas geomtricas de armadura de la seccin de la figura determinar qu resistencia


mnima debera tener el hormign para garantizar una rotura dctil en flexin pura. En tal caso
dibujar la influencia de la resistencia del hormign en el momento ltimo.
Solucin

1. Se plantea el equilibrio en la seccin para un plano de rotura en el dominio 3:

N = 0.85f by + A f - A f
N (d-v) + M = 0.85f by d - y2 + A f (d-d)
d

cd

yc,d

cd

[1]

yd

[2]

yc,d

Dividiendo la primera expresin por (f bd) y la segunda por (f bd ), se obtiene:


N = A f - A f + 0.85 y
f bd f bd
f bd
d
y
N d - v + M = A f d - d + 0.85 y d - 2
d
d d
f bd d f bd f bd
cd

cd

'

yc,d

cd

yd

cd

'

cd

'

yc,d

cd

cd

Definiendo los siguientes parmetros adimensionales:


N
n =
f b d : axil relativo
M : momento relativo
m =
f bd
A f : cuanta mecnica de compresin
w =
f bd
A
w=
f b d f : cuanta mecnica de traccin
d

cd

cd

'

'

[3]

cd

yc,d

cd

yd

cd

se obtienen las siguientes ecuaciones adimensionales:

Los autores, 1998; Edicions UPC, 1998.

[4]

175

E.L.U. agotamiento por solicitaciones normales

n = w'-w + 0.85
d

y
d

v
n 1 - + m = w
d
d

d
1 d

'

'

[5]

y
y
+ 0.85 1 d
d
2

[6]

Si se supone que y = 0.8x, las anteriores ecuaciones quedan como sigue:


x
n = w - w + 0.68
d
d
x
x
v

n 1 - + m = w 1 - + 0.68 1 - 0.4
d
d
d
d

[7]

'

[8]

'

'

As pues, la expresin que permite determinar la profundidad relativa de la fibra neutra en rotura es:
x = n +w-w
[9]
d
0.68
En el caso especfico del problema, los valores que se han de considerar son los siguientes:
f = 30/1.5 = 20 MPa
f = 500/1.15 = 434.78 MPa
f = 400 MPa
600
w =
20 300 450 400 = 0.089
1885 434.78 = 0.304
w=
20 300 450
dado que nos encontramos en flexin pura, n = 0.
Sustituyendo estos valores en la expresin [9] anteriormente hallada, se obtiene:
x = 0.304 - 0.089 = 0.316
d
0.68
2. La rotura ser crtica cuando la profundidad de la fibra neutra sea tal que se produzca
simultneamente la rotura del hormign (e = e = 0.0035) y la plastificacin del acero (e = e =
f /E = 2.1710 ). Dicha profundidad se obtiene planteando la compatibilidad de deformaciones en
la seccin:
'

cd

yd

yc,d
'

yd

cu

-3

cu

x

d

Los autores, 1998; Edicions UPC, 1998.

e +e
cu

=
lim

cu

= 0.617

cu

e +e

176

Hormign armado y pretensado. Ejercicios

Conocido este valor de la profundidad relativa de la fibra neutra y considerando flexin simple (n
= 0), la expresin [7] proporciona la relacin entre las cuantas mecnicas de las armaduras de
traccin y compresin de forma que la rotura sea crtica:
w - w = 0.42
3. El esfuerzo axil de compresin adimensional que provoca una rotura crtica se obtiene a partir de
la expresin [7]. Considerando los valores especficos de la seccin del problema ( w' = 0.089 ,
x
w = 0.304 ) y la profundidad relativa lmite que provoca una rotura crtica = 0.617 , el axil
d
n es:
x
n = w - w + 0.68 = 0.089 - 0.304 + 0.420 = 0.205
d
d

lim

crit

'

crit

lim

4. El dimensionamiento se realiza resolviendo el sistema formado por las expresiones [7] y [8]
particularizadas para los siguientes valores:
M = 380 kNm m = 0.313
n =0
[7]
0.313 = 0.889 w + 0.68 xd 1 - 0.4 xd

[8]
0 = w - w + 0.68 xd
d

'

'

a) x = x

lim

x/d = 0.617 w <0 A = 2.26 cm (2 f 12, armadura de montaje)


w = 0.420 A = 26.08 cm
A = 28.34 cm
b) x = 0.45d
w = 0.070 A = 4.73 cm
w = 0.376 A = 23.35 cm
A = 28.08 cm
c) x = 0.3d
w = 0.150 A = 10.13 cm
w = 0.354 A = 21.98 cm
A = 32.11 cm
s

s,tot

s,tot

s,tot

Los autores, 1998; Edicions UPC, 1998.

177

E.L.U. agotamiento por solicitaciones normales

5. Para garantizar que la rotura ser dctil, se habr de verificar la relacin obtenida en el apartado
2. Por otra parte, al tratarse de flexin pura, se ha de adoptar un valor nulo para n . As pues, las
ecuaciones de equilibrio en el caso de rotura crtica en flexin simple son:
w = w + 0.420
d
m = w 1 - + 0.316
d
d

'

'

donde para la seccin particular del problema:


A 'f = 600 400 = 1.778
w =
f b d f 300 450
f
f
A
1885
6.071
w=
f b d = f 300 450 434.78 = f
s

'

yc,d

cd

cd

cd

yd

cd

cd

cd

con f expresado en Mpa.


cd

De la primera ecuacin se obtiene:


1.778 - 6.071 + 0.420 = 0 f
f
f
cd

cd,min

= 10.22 MPa f

ck ,min

= 15.33 MPa

cd

Combinando las expresiones [8] y [9] para el caso de flexin simple (n = 0), se obtiene que el
momento ltimo adimensional de la seccin del problema, en funcin de la resistencia del
hormign, es:
5.873 - 10.840
m =
f
f
Si se considera el momento ltimo dimensional:
d

cd

cd

M = m f bd = 356.78 - 987f .80


d

cd

ck

donde M y f se expresan en kNm y MPa, respectivamente.


d

ck

Los autores, 1998; Edicions UPC, 1998.

178

Hormign armado y pretensado. Ejercicios

Momento ltimo de la seccin


350,00

337,02

Md (kNm)

317,27

300,00

250,00
15,3

20

25

30

35

40

45

50

fck (MPa)

Se observa que cuando la rotura es dctil, la resistencia del hormign influye relativamente poco en
el momento ltimo. Por ejemplo, para una resistencia del hormign f = 25 MPa, se obtiene un
momento ltimo M = 317.27 kNm, mientras que para f = 50 MPa, M = 337 kNm; es decir,
un aumento del 6.2%.
ck

ck

Los autores, 1998; Edicions UPC, 1998.

179

E.L.U. agotamiento por solicitaciones normales

Ejercicio II-2 Dimensionamiento y comprobacin de secciones rectangulares en


flexin simple

Considrese una seccin rectangular de 0.30 x 0.50 m , sometida a un momento flector, con las
siguientes caractersticas de los materiales:
- hormign: HA-25/P/20/Iia
f = 25 N/mm ;
- armaduras: Barras de acero corrugado B-500-S
f = 500 N/mm .
Se consideran los valores de los coeficientes parciales de seguridad correspondientes a un nivel de
control normal.
2

ck

yk

Se pide:

1. Dimensionar la armadura necesaria para hacer frente a un momento de clculo de:


300 kN.m
350 kN.m
2. Calcular el momento ltimo que puede resistir la seccin suponiendo la siguiente armadura:
- slo armadura de traccin A = 1885 mm (6 20);
- la misma armadura de traccin ms 3 16 en compresin.
En ambos apartados deberan realizarse los clculos tanto utilizando el diagrama rectangular como
el parbola-rectngulo.
s

Solucin

Resistencia de clculo del hormign.

25 = 16.67MPa
g
1.5
f = fg = 1500
.15 = 435MPa
f = 400 MPa

cd

ck

Resistencia de clculo a traccin del acero.


Resistencia de clculo a compresin del acero.

yk

yd

ycd

Recubrimiento mnimo por durabilidad: La tabla 37.2.4 de la instruccin EHE establece para la
clase de exposicin IIa un recubrimiento mnimo de 25 mm (distancia del paramento a la armadura
ms exterior, que es la transversal, como indica la figura). Adoptando para 10 mm y 20
mm, obtenemos
t

Los autores, 1998; Edicions UPC, 1998.

180

Hormign armado y pretensado. Ejercicios

La fila inferior de armadura longitudinal estar a 45 mm del paramento inferior. Por tanto, si slo
se necesitase una armadura sera suficiente adoptar un recubrimiento mecnico de 50 mm. Pero a
priori este dato no se conoce, por lo que adoptaremos g = 60 mm y d = h-r = 440 mm.
1 Dimensionamiento de la arm adura necesaria:

0 = 0.85f by + A f A . f
M = 0.85 f .b.y.(d-y/2) + A f (d-d)
cd

yc,d

cd

yd

yc,d

U = f b d = 16.67 300 44010 = 2200 kN


U = f b d = 968 kN.m
M = 0.319 U = 308.8 kN.m
a) M =300 kN.m
M < M , por tanto no hace falta armadura de compresin.
c

cd

-3

cd

cd

lm

cd

lm

U = A f = 0.85 U (1 - 1 - 0.852MU d ) = 896.9 kN


.910 = 2062 mm
A = Uf = 896435
s1

s1

yd

s1

s1

yd

Se necesitarn 6 20 + 2 12 = 2111 mm o bien 7 20 = 2199 mm . Adoptemos la primera


solucin, disponiendo los 6 20 en la fila inferior y los dos 12 en la superior.
2

45 + 2 1.13 85 = 49.28
x = 6 36.14 3.14
+ 2 1.13
g

Los autores, 1998; Edicions UPC, 1998.

181

E.L.U. agotamiento por solicitaciones normales

b) M = 350 kN.m
U =A f = M d -- Md' = 350440- -30850.810 = 105.6 kN
Como M > M
.610 = 264 mm
A = 105400
Se dispondrn 3 12 (A = 3.39 cm )
U = 0.425 U + U = 935 +105.6 = 1040.6 kN
A = Uf = 2392 mm
d

lm

s2

s2

yd

lim

s2

s2

s1

s2

s1

s1

yd

Se dispondrn 6 20 en la fila inferior y 3 16 en la superior, con un total de 24.88 cm , siendo


el centro de gravedad del conjunto:
x = 6 3.14 4524+.883 2.01 85
2

(montaje)

16

Solucin con el mtodo parbola-rectngulo:


0 = jf bx + A f -A f
M = jf .b.x.(d-lx) + A f (d-d)
cd

cd

yc,d

yd

yc,d

Para dimensionar se obliga a que la rotura sea dctil (dominio 2 o 3). El momento lmite vale, en
este caso, siendo j = 0.688 y l = 0.416, (e = 0.0035):
M =jf .b.x .(d-lx )=0.68816.67300271.5(440-0.416271.5)=305.5 kN.m
cu

lim

cd

lim

lim

Los autores, 1998; Edicions UPC, 1998.

182

Hormign armado y pretensado. Ejercicios

X = de
1+ e

d
= 0.617 d = 0.6170.44 = 0.2715 m
0
.
002175
1 + 0.0035

lim

cu

a) M =300 kN.m
Como M < M , no har falta armadura de compresin; por tanto, despejando x de la ecuacin de
equilibrio de fuerzas y sustituyendo en la de momentos, se tiene:
X = jAff b ; M = A f ( d - ljAf fb )
d

lim

yd

yd

yd

cd

cd

Lo que proporciona una armadura:


2M ) = 908.8 kN
A f = 0.827 U (1 - 1 - 0.827
U d
A = 435908 10.8 = 2089 mm
Se necesitaran 6 20 + 2 12 = 2111 mm , que es la misma armadura obtenida con el mtodo
del rectngulo.
b) M =350 kN.m
Como M > M ,
U = M d -- Md' = 3500-.39305.5 = 114.1 kN
.1
A = 114
400 10 = 285.3 mm 3f12
U = j f b x + A f = (0.68816.67300271.5 + 114100)10 =1048 kN
A = 1048
435 10 = 2409 mm
s

yd

-3

lim

s2

s2

s1

cd

lim

s1

lim

-3

ycd

Se dispondrn 6 20 + 3 16 = 2488 mm , que es la misma armadura obtenida con el mtodo


del rectngulo.
2

2. Clculo del momento ltimo: mtodo del rectngulo

Siendo A = 1885 mm (6 20) en una sola fila, el canto til para que se satisfaga estrictamente la
condicin de durabilidad ser de d = h r = 500-45 = 455 mm.
U = f b d = 16.67 300 455 10 = 2275.5 kN
U = f A = 1885 435 10 = 820 kN
U = A f = 603 400 10 = 241.2 kN (en el caso b)
2

s1
s2

-3

cd

yd

s2

s1

yc,d

-3

-3

Los autores, 1998; Edicions UPC, 1998.

183

E.L.U. agotamiento por solicitaciones normales

a) Slo armadura de traccin. Veamos el dominio de rotura:


Dominio 2 entre x = 0 y x = 0.259d
Dominio 3 entre x = 0.259d y x =x
X = 0.617d

lim

lim

Para conocer x se despeja de la ecuacin de equilibrio de fuerzas. En ambos dominios la armadura


de traccin est plastificada y la de compresin tambin, siempre que x > 0.167d.
y = A f0.85- Af ' bf = 0.85820000
= 192.9 mm
16.67 300
X = 1.25y = 241.12 mm = 0.53d; por lo tanto se trata del dominio 3
M =0.85 f b y (d y/2)=0.8516.67 300192.9(455-192.9/2)10 =294 kN.m
b) Armadura de traccin y compresin
- 241.2 ) 10
y = (820
0.85 16.67 300 = 136.2 mm
X=1.25y=170.2=0.37d. Se trata tambin del dominio 3.
M = 0.85 f b y(d - y 2) + A f (d - d' ) =
136.2 ) 10 + 241.2 (0.455 - 0.045) = 322.9 kN.m
= 0.85 16.67 300 136.2 ( 455 2
s

yd

yc,d

cd

-6

cd

'

cd

ycd

-6

Solucin por el mtodo de la parbolarectngulo:


Al igual que en el mtodo del rectngulo, se despeja x de la ecuacin de equilibrio de fuerzas y se
sustituye en la de momentos.
x = A f j-f Ab' f ,
M = j f b x (d - lx) + A f (d - d)
Si estamos en dominio 3, j = 0.688m y l = 0.416.
Caso a) sin armadura de compresin
X = 0.688820000
16.67300 = 238.3 mm
s

yd

yc,d

cd

cd

yc,d

Los autores, 1998; Edicions UPC, 1998.

184

Hormign armado y pretensado. Ejercicios

M =820 (455 0.416 238.3)=291,8 kN.m (99.2 % del calculado por el mtodo del
rectngulo).
Caso b) con armadura de compresin
- 241.2 )10
X = (820
0.68816.67300 = 168.2mm
M = (0.688 16.67 300 168.2 (455 0.416 168.2) + 241200 (455-45))10
= 321.72 kN.m (99.6 % del obtenido mediante el mtodo del rectngulo).
u

-6

Los autores, 1998; Edicions UPC, 1998.

185

E.L.U. agotamiento por solicitaciones normales

Ejercicio II-3 Dimensionamiento y comprobacin de secciones rectangulares


en flexocompresin recta
Considrese

una

seccin

rectangular

de

hormign

armado

de

0.30

0.50

m,

sometida

flexocompresin recta, cuyas caractersticas de los materiales son:


- hormign: H-25 / P / 20 IIa, fck = 25 MPa;
- armaduras: barras corrugadas de acero B-400-S, fyk = 400 MPa.
Se consideran los valores de los coeficientes parciales de seguridad correspondientes a control de
calidad intenso.

Se pide:
1.

Dimensionar las armaduras necesarias para los cuatro casos de carga siguiente, por el mtodo
del rectngulo:
a) Nd = 1000 kN; Md = 100 kN.m;
b) Nd = 800 kN;

Md = 200 kN.m;

c) Nd = 1000 kN; Md =

200 kN.m;

d) Nd = 2500 kN; Md = 100 kN.m.


2.

Comprobar la seccin frente a los casos de carga siguiente, suponiendo que est armada con 3

20 (942 mm ) en cada cara, y que el canto til es d = 0.45 m, d = 0.05 m.


2

a) Nd = 800 kN;

Md =

200 kN.m;

b) Nd = 2500 kN; Md = 100 kN.m.

Solucin

1.

Dimensionamiento

f cd

- resistencia de clculo del hormign:

- resistencia de clculo del acero:

f yd

=f

yc,d

f ck

f yk

25
1.5

400
1.15

Los autores, 1998; Edicions UPC, 1998.

= 16.67MPa
= 348MPa

186

Hormign armado y pretensado. Ejercicios

Por razones de durabilidad, el recubrimiento geomtrico deber ser de 25 mm, lo cual implica que
considerando una armadura transversal de

10 mm,
20 ).
t

la capa exterior de la armadura longitudinal

mecnico de 45 mm (para el caso de utilizar

Adoptaremos r = 50 mm, con lo que d = h r = 450 mm y d = r = 50 mm:


-3

Uc = fcd b d = 16.67 300 45010

= 2250 kN;

Ucd = fcd b d = 2250 0.45 = 1012.7 kN.m;


Mlim = 0.319 Ucd = 0.319 1012.7 = 323 kN.m.
Las ecuaciones de equilibrio son:

Nd = 0.85 fcd b y + As2 fyc,d As1 fyd


Nd e = 0.85 fcd b y (d-y/2) + As2 fyc,d (d-d)

Md

e =

a)

Nd

+d-

h
2

Nd = 1000 kN; Md = 100 kN.m.

e =

100
1000

+ 0.45 - 0.25 = 0.1 + 0.45 - 0.25 = 0.3m

Nd e = 300 kN.m < 323 kN.m = Mlim


Por tanto, no har falta armadura de compresin. Despejando y de la ecuacin de momentos, y
sustituyndola en la de fuerzas se obtendr As1

Us1 = As1 fyd = 0.85 Uc (1

2 N d e

0.85 U c d

- N = -140 < 0
d

Por tanto debera disponerse de armadura mnima.

As fyd

0.25

As2 fyd

W1

f cd

= 0.25

bh
12

0.05 N

f cd

= 0.25

bh
6

f cd

= 104 kN

= 0.05 1000 = 50 kN

Ello se consigue disponiendo 1

16 en cada esquina.

Los autores, 1998; Edicions UPC, 1998.

187

E.L.U. agotamiento por solicitaciones normales

b) Nd = 800 kN; Md = 200 kN.m

e =

200
800

+ 0.45 - 0.25 = 0.45m

Nd e = 800 0.45 = 360 kN.m > Mlim


Por tanto har falta armadura de compresin.
Esto se obtiene haciendo y = ylim =0.50d

As2 fyc,d =

-M
d - d'

N d e

lim

360

- 323

0.40

= 92.5kN

As1 fyd = 0.425 Uc + As2 fyc,d - Nd = 248.7 kN


As1 =

As2 =

248.710

348
92500
348

= 715mm

= 266 mm

(2

(4

16 o 3 20)

16)

La disposicin de armaduras adoptada ser:

20

c) Nd = 1000 kN; Md =

200 kN.m

Por tratarse de un momento que puede tener signos contrarios se deber dimensionar con armadura
simtrica.

Los autores, 1998; Edicions UPC, 1998.

188

Hormign armado y pretensado. Ejercicios

Nd > 0.425 Uc = 0.425 2250 = 956.2 kN


Por tanto, el proceso es: siendo e = 0.2 + 0.45 0.25 = 0.4 m

As fyc,d = As fyc,d =
192500

As = As =

348

-M
d - d'

N d e

= 553mm

lim

(2

Se adoptar una armadura consistente en 3

- 323

1000 0.4
0.40

= 192.5kN

20 o 3 16)
16 por cara (A

= As = 603 mm )

d) Nd = 2500 kN; Md = 100 kN.m


En este caso puede convenir dimensionar las armaduras para que la seccin est sometida a
compresin simple, esto es, para que la resultante de los esfuerzos solicitantes coincida con el
baricentro plstico de la seccin.
En tal caso, las ecuaciones de equilibrio son:
Nd = 0.85 fcd b h + As2 fyc,d As fyd
Nd e = 0.85 fcd b h (d - h/2) + As2 fyc,d (d - d)
As2 fyc,d =

- 0.85 f

N d e

b h (d - h / 2)
=
- d'

cd

600

- 425

0.40

= 437.5kN

As1 fyd = - Nd + 0.85 fcd b h + As2 fyc,d = 0.85 fcd b h+As2 fyc,d Nd = 62.9 kN
As2 =

A s1

437.510

= 1257 mm

348

62.9 10
348

(4

= 181 mm <
2

20)

Amn, por lo tanto se dispondr armadura mnima en la zona

menos comprimida.
Amn=

0.05N d
f yd

0.05250010
348

= 359 mm

(2

16)

Los autores, 1998; Edicions UPC, 1998.

189

E.L.U. agotamiento por solicitaciones normales

2 Comprobacin
-3

Uc = fcd b d = 16.67 300 450 10


-3

Us1 = Us2 =As fyd = 942 348 10


a)

= 2250 kN

= 327.8 kN

Nd = 800 kN; Md = 200 kN.m

Si 0.22 Uc < Nd + Us1 Us2

0.425 U

+ Us1 Us2 el dominio de rotura es el 3.

En el caso que nos ocupa,


0.22 Uc = 495 kN; 0.425 Uc = 956 kN
Nd + Us1 Us2 = 800 kN,
Al estar en dominio 3,

s1

= fyd,

luego se satisface la ecuacin.

s2

= fyc,d.

De la ecuacin de equilibrio despejamos y= 188 mm y sustituimos en la ecuacin de momentos:


Mu = 0.85 fcd b y (d-y/2) + As2 fyc,d (d-d)
-6

= 0.85 16.67 300 188 (450 188/2) 10

+ 327.8 0.4

= 415.62 kN.m > Md = 100 kN.m


Luego, la seccin resiste.
b)

Nd = 2500 kN; Md = 100 kN.m

Dado que el axil es muy superior al momento es probable que la rotura se produzca en los dominios
4, 4.a o 5. Las ecuaciones que establecen los planos frontera son:

N < 0.68 U + U
N 0.68 U h/d + U + U

Dominio 4

0.425 Uc + Us1 Us2

Dominio 4.a

0.68 Uc + Us2

Dominio 5

Us1 700 /fyd (1-d/h) < Nd

Para el caso que nos ocupa, estas ecuaciones se traducen en:

Los autores, 1998; Edicions UPC, 1998.

s2

s2

s1

700 /fyd (1-d/h)

190

Hormign armado y pretensado. Ejercicios

N 1857.8
N 2093 kN

Dominio 4

956.25

Dominio 4.a

1857.8

Dominio 5

2093 < Nd

d
d

Dado que Nd = 2500 kN > 2093 kN la rotura se producir en el dominio 5, en el cual x>h. En el
caso el valor de y resulta ser:
0.0035

y =

x
x

- 0.8h
h
- 0.75h

s1

s1

e
x-d

s1

-d
x

= Es

s1

El equilibrio de fuerzas ser:

- 0.8h
+ U + A s
x - 0.75h
x

Nd = 0.85 fcd b h

Teniendo en cuenta que

s2

= Es

s1

Nd = 0.85 fcd b h

s1

s1

= Es 0.0035

- 0.8h
+ U + A E
x - 0.75 h
s1

-d
x

s2

s1

0.0035

-d
x

La solucin de esta ecuacin proporciona el valor de x = 0.678 m.

Con lo cual

y =

- 0.8h
h =
- 0.75h

x
x

0.678
0.678

- 0.8 0.5
0.5 = 0.458 m
- 0.750.5

Mu = 0.85 fcd b y (d - y/2) + Us2 (d - d) = 561.4 kN.m


Nde = 2500 (e0 + d - h/2) = 2500 (100/2500 + 0.45 0.25) = 600 kN.m
Por tanto la seccin no resiste.
Si dimensionamos la seccin con armadura simtrica se tendra, dado que Nd > 0.425Uc

Us1 = Us2 =

As1 = As2 =

-M
d - d'
692.5 10
N d e

348

lim

600

- 0.319U
0.40

= 692.35 kN

= 1990 mm > 942 mm


2

lo que verifica que la seccin no resiste.

Los autores, 1998; Edicions UPC, 1998.

0.0035

191

E.L.U. agotamiento por solicitaciones normales

Ejercicio II-4 Dimensionamiento y comprobacin de secciones mediante diagramas


de interaccin en flexin recta y esviada
2

Un soporte de hormign armado, de 0.50 x 0.40 m cuyas caractersticas de los materiales son:
- hormign:

H-30/P/20/IIa

fck = 30 MPa

- armaduras

barras corrugadas de acero B 400S

fyk = 400 Mpa

est sometido a las siguientes hiptesis de carga.

500 kN.m;

a) Nd = 1500 kN;

Mdx =

b) Nd = 2000 kN;

Mdx = 160 kN.m;

Mdy = 0
Mdy = 200 kN.m

Se pide:
1. Dimensionar las armaduras necesarias para resistir ambas solicitaciones, disponiendo en el caso
a) armadura simtrica en dos caras opuestas y en el caso b) armadura igual en las cuatro caras y en
las cuatro esquinas.
2.

Suponiendo

la

seccin

armada

como

indica

la

figura

verificar

si

resiste

solicitaciones:
a) Nd = 2000 kN;

Md = 600 kN.m;

b) Nd = 1600 kN;

Mdx = Mdy = 200 kN.m

Mdy = 0

Solucin

f cd

Resistencia caracterstica del hormign

Resistencia caracterstica del acero

f yd

f yk
1.15

=
=

f ck
1.5
400

1.15

= 20N / mm

= 347.83 N / mm

Los autores, 1998; Edicions UPC, 1998.

las

siguientes

192

Hormign armado y pretensado. Ejercicios

1 Dimensionamiento utilizando diagramas de interaccin


a) Flexocompresin recta
Los valores adimensionales son:

n =

Nd

1500 10

= 0.375
b h 20 400 500
N e
500 10
m =
=
= 0.25
f bh
20 400 500
d

f cd

cd

Entrando en el diagrama de interaccin correspondiente a armadura simtrica con d =0.1h=50


mm la curva que pasa por el punto representativo es

tot

A s,tot
Ac

yd

= 0.37 A

s,tot

0.37 20 400 500

cd

w = 0.37.

As1 = As2 = 2127.5 mm , que corresponde a 7

347.83

= 4255 mm

20 en cada una de las caras que caben en una sola

fila, satisfacindose el recubrimiento necesario por durabilidad (25 mm).


235+720+6d = 400; d=31.6 mm.

Como la distancia entre barras es superior al dimetro de las mismas (


mximo del rido (20 mm) la disposicin es correcta.
b) Flexocompresin esviada
Nd = 2000 kN

Mdx = 160 kN.m


Mdy = 200 kN.m

Los autores, 1998; Edicions UPC, 1998.

20 mm) y al tamao

193

E.L.U. agotamiento por solicitaciones normales

Los valores adimensionales son:

n =
d

m
m

dx

dy

Nd
f cd

=
c

M dx
f cd

bh
hb

20

M dy
f cd

2000 10

= 0.5

400 500

160 10

20 400 500

200 10

20 500

= 0.08

= 0.125

400

Entrando en el baco roseta para flexin esviada adimensional correspondiente a la armadura igual
en las cuatro caras
dx = 0.10 h = 50 mm
dy = 0.10 b = 40 mm
y teniendo en cuenta,

dy

>

dx

dy

dx

la curva que pasa por el punto representativo es:

Los autores, 1998; Edicions UPC, 1998.

194

Hormign armado y pretensado. Ejercicios

tot

A stot

n = 0.4

= 0.25

n = 0.6

= 0.32

A stot

Ac

f
f

yd

stot

w A f

cd

0.285 20 400 500


347.83

tot

= 0.285

cd

f yd

= 3278

Atot = 4A

mm

A = 819.5 mm en cada lado

Los autores, 1998; Edicions UPC, 1998.

195

E.L.U. agotamiento por solicitaciones normales

20

En cada esquina disponemos 1

16,

y en cada cara 3

20

teniendo as (4

16)

+ 12

= Astot =

3669.4 mm

20 cm > l >

20
20

20 cm > l >

2 Verificaciones
a)

Flexocompresin recta
Nd = 2000 kN
Nd = 600 kN

20

Astot = 16

Obtencin de los esfuerzos:


6

Uc = bhfcd = 50040020 = 410 N


Se buscan los valores adimensionales:

n =

Nd

m =

Nd

2000 10

Uc

4 10

= 0.5

e
600 10
=
= 0.3
h 4 10 500
6

Uc

Entrando en el diagrama de interaccin correspondiente a la armadura igual en las cuatro caras y en


las cuatro esquinas

nec

= 0.73, cuanta que resulta necesaria.

La cuanta total existente vale:

w=

A stot

yd

Uc

5026.55 347.83

4 10
2

Astot = 5026.55 mm

w
w

disp
nec

= 0.44
>

disp

= 0.44
20

16

cuanta disponible.
la seccin es insuficiente.

Los autores, 1998; Edicions UPC, 1998.

196

b)

Hormign armado y pretensado. Ejercicios

Datos
Nd = 1600 kN
Mdx = Mdy = 200 kN.m

Obtencin de los esfuerzos:


6

Uc = bhfcd = 50040020 = 410 N


Se buscan los valores adimensionales:

n =
d

dx

dy

Nd
Uc

M dx
Uc

N dy
Uc

1600 10

4 10

=
=

= 0.4

200 10

4 10

500

200 10

4 10

400

= 0.1
= 0.125

Los autores, 1998; Edicions UPC, 1998.

197

E.L.U. agotamiento por solicitaciones normales

Entrando en el diagrama de interaccin correspondiente a la armadura igual en las cuatro caras y en


las cuatro esquinas

nec

= 0.3

La cuanta total existente vale:

w=

A stot

Uc

yd

4 10

Astot =5026.15 mm

disponible >

(1620)

5026.55 347.83

w necesaria

= 0.44 w disponible

la seccin es suficiente

Los autores, 1998; Edicions UPC, 1998.

199

E.L.U. agotamiento por solicitaciones normales

Ejercicio II-5 Comprobacin del E.L.U de flexocompresin de secciones pretensadas


con armadura adherente y no adherente
Una placa unidireccional de un forjado pretensado con armaduras postesas presenta la seccin
transversal que se esquematiza en la figura adjunta.

El forjado, de 14 m de luz, trabaja simplemente apoyado, y tiene las siguientes cargas actuantes:
2

- cargas permanentes: 6 kN/m ;


2

- sobrecargas de uso: 4 kN/m .


Se considera un control intenso de la ejecucin.
Se proyectan dos soluciones, una con armaduras adherentes y otra con armaduras no adherentes. En
2

ambos casos, la armadura activa est constituida por 3 cordones de 0.6 (Aptot = 420 mm ),cuya
excentricidad respecto del centro de gravedad en la seccin central es e = -360 mm. La tensin
inicial de tesado en anclajes es Pancl = 520 kN, y la fuerza final, tras prdidas instantneas y
diferidas, en la seccin central es P = 400 kN en ambos casos.
Las caractersticas de los materiales son:
- hormign: fck= 35 MPa
- armaduras activas: fpyk=1700 MPa
- armaduras pasivas: barras B500S, fbk=500 MPa
Se pide:
Verificar el estado lmite ltimo de agotamiento por flexocompresin en la seccin central.

Solucin
Resistencias de clculo de los materiales:

Los autores, 1998; Edicions UPC, 1998.

200

Hormign armado y pretensado. Ejercicios

- hormign:

f cd

- armaduras activas:

f pyd

- armaduras pasivas:

f yd

=
=
=

f ck

gc

f pyk

gs
f yk

gs

35
1.5

- momento solicitacin de clculo: M d

= 23.33 MPa

1700
1.15

500
1.5

= 1478.26 MPa

= 434.78 MPa

= 1.35

0.8 6 14
8

+ 1.5

0.8 4 14
8

= 276.4 kN.m

a) Armadura adherente
En tal caso, la armadura acompaa al hormign en su deformacin, incrementando su traccin en el
E.L.U.

D
El equilibrio de fuerzas proporciona:
P

= C - DT C = P + DT

Se hacen dos hiptesis: 1) que el bloque de compresiones C cae dentro de la cabeza superior y 2)
que la rotura es dctil, es decir,

P + DT = A p f pyd .

En tal caso se tiene:


C

= 0.85 f cd b y = A p f pyd = 620.9 kN

620.9 10

0.85 23,33 800

= 39.1 mm < 150 mm

luego el bloque de compresiones cae dentro de la cabeza de compresin (y<hf).


El momento ltimo ser:

= C z = A p f pyd ( d p - y / 2 ) = 620.9 ( 0.5 - 0.0391 / 2 ) =


= 298.3 kN.m > M d = 276.4 kN.m

Mu

Los autores, 1998; Edicions UPC, 1998.

201

E.L.U. agotamiento por solicitaciones normales

por tanto, se verifica la seguridad a rotura.


En cuanto a la rotura dctil se tiene:
x = 1.25y

x = 48.9 mm

De p
e
= c De p = e c
dp - x
x

e p e p + De p =
e py =

f pyd
Ep

P
EpAp

1478.26

2 10

dp

-x

+ De p =

= 0.0035

42

400 10

2 10

0.5

- 0.0489

0.0489

= 0.032

+ 0.032 = 0.08

= 0.00739 < e p

por tanto, la armadura plastifica y la rotura es dctil.


b) Armadura no adherente
En este caso, no existe compatibilidad de deformaciones a nivel seccin, sino compatibilidad de
desplazamiento en anclajes. Por tanto, es muy difcil evaluar el incremento de traccin de la
armadura en rotura.
Una cota inferior del momento ltimo puede obtenerse considerando nulo el momento de traccin,
lo cual conduce a lo siguiente:
C

= 0.85 f cd b y = P = 400 kN

Mu

400 10

0.85 23,33 800

= 25.2 mm

= C z = P ( d p - y / 2 ) = 400( 0.5 - 0.0252 / 2 ) = 195 kN.m

Como se observa, en este caso Mu < Md = 276.4 kN.m, por lo que hara falta disponer una
armadura pasiva adicional para resistir la diferencia

DM = Md -Mu.

Para calcular la armadura pasiva necesaria, se dimensiona sta considerando la presencia del axil P
de pretensado, en su posicin real, como capa exterior. Las ecuaciones de equilibrio son:
P

= C - A s f yd ; C = P + A s f yd = 0.85f cd b y

Md

+ P (d s - d p ) = C z = C (d s - y / 2)

Los autores, 1998; Edicions UPC, 1998.

202

Hormign armado y pretensado. Ejercicios

Se trata de un sistema de dos ecuaciones con dos incgnitas, que son y, y As. La solucin del
sistema lleva a:

A s f yd

As

= 0.85 f cd b d s 1
156700
434.78

+ P ( d s - d p ))
- P = 156.7 kN
2
0.85f cd b d s

2( M d

= 360 mm 2 2f16 = 400 mm 2

La disposicin de armaduras sera entonces:

Los autores, 1998; Edicions UPC, 1998.

203

E.L.U. de agotamiento por solicitaciones tangenciales

Ejercicio II-6

Esfuerzo cortante en vigas de hormign armado y pretensado con


armaduras pretesas

Para cubrir un depsito de agua potable de grandes dimensiones se ubican en su interior pilares
segn una cuadrcula de 8.30 x 6.00 m. Sobre estos pilares se disponen jcenas de canto de 0.40 x
0.75 de hormign, de 8.00 m de luz, simplemente apoyadas. Sobre ellas se dispone un forjado
unidireccional continuo de 6.00 m de luz.
Las cargas que se deben considerar son:
- peso propio de las vigas 7.5 kN/ml;

- peso del forjado y cargas muertas 4 kN/m ;

- sobrecarga superior (tierras o trfico ligero) 7.5 kN/m .


Se prev un control de ejecucin intenso. Se tantean dos soluciones para las jcenas de hormign,
ambas con las mismas dimensiones, pero una de hormign armado construida

in situ

y otra

prefabricada pretensada con armaduras pretesas como indica la figura adjunta.

Las caractersticas de los materiales son:


Para la jcena de hormign armado HA-30/P/20/IIb, B-500-S.
Para la jcena de hormign pretensado HP-30/P/20/IIb, Y 1860 S7, B-500-S.
La jcena est pretensada con 6 cordones de

0.6 (Ap=840 mm ) y la fuerza final de pretensado

es P = 900 kN.
Se pide:
1. Dimensionar a cortante las jcenas en cada una de las dos soluciones anteriores y hacer un
esquema de la disposicin de armaduras longitudinales y transversales.

Nota:

las armaduras longitudinales, tanto las activas como las pasivas, recorren la totalidad de la

pieza, anclndose en sus extremos.

Los autores, 1998; Edicions UPC, 1998.

204

Hormign armado y pretensado. Ejercicios

ps es de montaje Aps

armadura de compresin fruto del clculo.

Solucin

Cargas permanentes

g = 7.5 kN/m + 4 kN/m 6 m = 31.5 kN/m

Cargas variables

q = 7.5 kN/m 6 m = 45 kN/m

gG = 1.35
gQ = 1.5

g* = 1.35 31.5 kN/m = 42.525 kN/m

q* = 1.5 45 kN/m = 67.5 kN/m


g** = 0.9 31.5 = 28.35 kN/m

II

Se ha tomado 0.9 como coeficiente de seguridad para las acciones remanentes favorables de acuerdo
con el criterio de EH-91, aunque EHE recomienda tomar 1.00.

113.4

Vx = R1 g*x = 170.1 42.525x


x = 0
x = 4
x = 8

Vx = 170.1 kN
Vx = 0

Vx = R1 g**x = 113.4 28.35x


x = 0

Vx = 170.1 42.525 * 8

x = 4
x = 8

Vx = 113.4 kN

Vx = 0 kN

Vx = -113.4 kN

= -170.1 kN

Carga variable

Los autores, 1998; Edicions UPC, 1998.

205

E.L.U. de agotamiento por solicitaciones tangenciales

III

IV

Vx

Vx

67.5
2*8

=-

(8

67.5

x = -4.2188 x

Vx

x = 8

Vx

x = 0

Vx

x = 8

Vx = - 270 kN

- x ) 2 = 4.2188(8 - x ) 2

2 8

+ = 270 kN

x = 0

+ = 0 kN
-

= 0 kN

- Caracterstica de los materiales

f cd

f yd

f pyd

f ck
1.5

f yk
1.15

30
1.5

f pyk

500
1.15
1700

1.15

= 20 N / mm 2

1.15

= 434.78 N / mm 2
= 1478.26 N / mm 2

- Esfuerzos en estado lmite ltimo

Cargas permanentes

g = 7.5 kN/m + 4 kN/m 6 m = 31.5 kN/m

Cargas variables

q = 7.5 kN/m 6 m = 45 kN/m


Md

= gG

gl

+ gQ

ql

= 1.35 31.5 kN / m

= (340.2 + 540 )kN / m = 880.2 kN.m

8 m

Los autores, 1998; Edicions UPC, 1998.

+ 1.5 45kN / m

206

Hormign armado y pretensado. Ejercicios

= gG

Vd

gl
2

+ gQ

ql
2

= 1.35 31.5

8
2

+ 1.5 45

8
2

= (170.1 + 270 ) kN = 440.1 kN

1 Solucin en hormign armad o

Vrd

= Vd + Vpd + Vcd

Vrd

Vu1

Vrd

Vu2 = Vcu+ Vsu

Vu1 = agotamiento por compresin oblicua del alma


Vu2 = agotamiento por traccin en el alma
Vrd

Vu1

Vu1

= K f1cd b 0 z

q + cot ga
2
1 + cot g q

cot g

coeficiente de reduccin por defecto del esfuerzo axil.

s cd p
1 +
<1
3
f cd

scdp tensin axil efectiva en la seccin (traccin positiva)


s cd p =

Nd

+ A s 2 s sd, c
Ac

As2 = 0, pues no hay armadura de compresin fruto del clculo.

axil de clculo incluido el pretensado con un valor de clculo


rea de armadura en la zona comprimida
Ac rea total de la seccin de hormign
ssd,c resistencia de clculo del acero a compresin
Nd

As2

ssd,cp = 0
f1cd

K = 5/3 < 1

K = 1

resistencia a la compresin del hormign


2

f1cd = 0.6 fcd = 0.6 20 N/mm = 12 N/mm

anchura neta mnima del elemento = 400 mm


brazo mecnico = 0.9 d = 0.9 680 mm = 612 mm

b0
z

q = 45 en hormign armado

q =1

cotg

Los autores, 1998; Edicions UPC, 1998.

207

E.L.U. de agotamiento por solicitaciones tangenciales

a = 90 cercos verticales
cot gq + cot ga
1
1
=
=
2
1+1
2
1 + cot g q

a =0

cotg

Vu1 = 1 12 N/mm 400 mm 612 mm 1/2 = 1468.8 kN

Vrd = 440.1 kN < Vu1 = 1468.8 kN


Vrd

cumple

Vu 2 = Vcu + Vsu contribucin del acero

contribucin del hormign

x(100 rl fck)1/3 0.15 scdp]b0db

Vcu = [0.10

200

x =1+
rl

= 680 mm ) = 1 +

, (d

200
680

= 1.5423

= cuanta geomtrica de la armadura longitudinal pasiva y activa adherente, ubicada a una

distancia igual o mayor que d a partir de la accin en estudio

As

r1 =
(As = 12

+ Ap
b0

f yp
f yd

< 0.02

20)

As

= 12

p 20 2
4

Ap = 0

rl =

3770 mm

680 mm
2
fck = 30 N/mm ,
400 mm

= 3769.91 mm 2 = 3770

= 0.0139 < 0.02


b0 = 400 mm
d = 680 mm

p
s cd
=0

q -1
2 cot gq e - 1
2 cot gq - 2
b=
2 cot gq e - 2

b=

cot g
fct,m

2 cot g

qe =

f ct ,m

0.5

cotgq cotgqe
qe cotgq 2

cotg

- f ct,m (s xd + s yd ) + s xd s yd
f ct ,m

- s yd

>0.5, <2

resistencia media a traccin (considerada positiva)


2
fck en N/mm
f
= 0.30 3 f 2
ct ,m

ck

sxd, = syd = 0, cotgqe = 1


cotgqe = cotgq = 1
b=1

Los autores, 1998; Edicions UPC, 1998.

mm

208

Hormign armado y pretensado. Ejercicios

Sustituyendo:

1/3]4006801 = 145.473 kN =

Vcu = [0.101.5423(1000.013930)
Vrd = Vcu + Vsu

145.5 kN

Vsu = Vrd Vcu = (440.1 145.5) kN = 294.6 kN = 294.610 N

S Aafyadzsena(cotga + cotgq) = S Aafyad0.9d=


S Aa434.78 N/mm2 612 mm= S Aa266085.4 Nmm/mm2

Vsu =
=

a = 90
q = 45

Aa266085.4 Nmm/mm = 294.610 N


Aa

294.6 10

Nmm

= 1.107

266085 .4 Nmm

mm

mm

mm

= 1.107

mm

10 mm
1m

= 1107

mm

- Verificacin de la condicin de lmite superior de Aa

S Aafyad
2

1
2

f1cdb0

sen
1

- cos a

1.107 mm /mm 434.78 N/mm = 481.302 N/mm


1
2

f1cd

b0

sen
1

- cos a

1
2

12 N / mm 2 400

= 2400

mm 1

N / mm

se cumple

- Verificacin de la condicin de armadura mnima:

0.20 ck + 0.75 b
sen a
20

2
fck = 30 N/mm

A a f ya d

b = 400 mm

A a f ya d

0.20

sen

= 481.302 N / mm

30N / mm 2

+ 0.75 400 = 180N / mm cumple


20

Distribucin de armadura transversal

Aa = 1.107 mm /mm= 1107 mm /m = 1107 mm /100cm = 11.07 mm /cm


StAa =

hr

p f2
4

hr = 2 ramas

= mm

St =

p f2
4 Aa

hr

mm 2

mm 2

cm

/ cm

Aa = mm /cm

Los autores, 1998; Edicions UPC, 1998.

209

E.L.U. de agotamiento por solicitaciones tangenciales

p f2
= 0.1419 f 2
4 11.07
10 mm St = 14 cm
12 mm St = 20 cm

St =

Comprobaciones de carcter general de St

0.80 d < 300 mm


0.60 d < 300 mm
St 0.30 d < 200 mm
St

si

St

Vrd = 440.1 kN

St

si
si

1/5 Vu1
Vrd 2/3 Vu1
Vrd > 2/3 Vu1
Vrd

1/5 Vu1

1/5 Vu1 = 293.76 kN

Vu1 =1468.8 kN
1/5 Vu1

2/3 Vu1 = 979.2 kN


Vrd 2/3 Vu1 St 0.60 d < 300 mm

0.60 d < 060680 mm = 408 mm < 300 mm


10/14 cm
12/20 cm
cumplen las dos

Si hay armadura comprimida y se tiene en cuenta en el clculo:

15 mn
t 1/4 mx

St

mn = de la barra comprimida ms delgada.


mx = de la barra comprimida ms gruesa.

Para piezas comprimidas, en cualquier caso,


St < dimensin menor del elemento.

St < 30 cm.

h
b

- Distribucin longitudinal de cercos

Vrd = 170.1 42.525x 4.2188x


Vcu = - 145.5 kN

la a partir del apoyo B


en la

10/14 cm
12/20 cm

x = 4.97 m

la = (8-4.9705) + 0.375 =3.4 m 3.5 m

Los autores, 1998; Edicions UPC, 1998.

210

Hormign armado y pretensado. Ejercicios

A partir de la, lleva Aamn

Aamnfyd = 180 N/mm

Aamn = 0.414 mm /mm = 4.14 mm /cm

p f2
4 Aa

St =

10

St =

12

St =

Adoptando los

Aa =

p 10 2
= 37.94cm < 300 mm
4 4.14
2
2 p 12
= 54.64cm < 300 mm
4 4.14
2

10 para Aa mnima, con St = 300 mm.


2

p f 2 2 p 10 2
= 0.5236 mm 2 / m ( > A amin )
=
4 St
4 300

2 Solucin en hormign preten sado


Vrd = Vd + Vpd + Vcd = Vd = 440.1 kN Vpd = 0

Vcd = 0

Vu1
Vrd Vu2
Vrd

Se adopta

q = qe. qe viene dada por

cot g

qe =

syd = 0

f ct ,m

- f ct,m (s xd + s yd ) + s xd s yd
f ct ,m
cot g

qe =

- s yd
1

>0.5, <2

s xd
f ct, m

Los autores, 1998; Edicions UPC, 1998.

211

E.L.U. de agotamiento por solicitaciones tangenciales

sxd = (compresin

) =

P
Ac

=-

900 10 N
400

750 mm

= -3 N / mm 2

= 0.30 3 f ck 2 = 2.9 N / mm 2

f ct , m
cot g

qe =

3
2.9

= 1.43 (0.5 cot gq e 2 )

Obtencin de Vu1:
Vu1 = Kf1cdb0z

q + cot ga
2
1 + cot g q

cot g

s cd p
1 +
<1
3
fcd

N d + A s 2 s sd, c
scdp =

K=

Ac

(compresin)

- 900 10 3 + 0
= -3 N / mm 2
400 750
5
3
K =
1
= 1.4167 > 1 K = 1
20
3
2
f1cd = 0.60fcd =12 N/mm
b0= 400 mm

scdp =

z = 0.9d = 0.5700 mm = 630 mm

a = 90

Vu1 = 112 N/mm 400 mm630 mm

1.43

= 1420.2 kN
+ (1.43) 2
cumple

Vu1 = 1420.2 kN
Vu2 = Vcu + Vsu
1/ 3
Vcu = 0.10 x (100r l fck )
- 0.15s cd p b 0 d b

Vrd = 440.1 kN
Vrd

x =1+
As

rl =
As

200
d

+ Ap
b0

6 20

=1+

200
700

= 1.5345

f yp
f yd

< 0.02
As = 6

p 20 2
4

= 1884.96 mm 2

6 6 Ap = 840 mm2
b0 400 mm
d 700 mm
2
fyd 434.78 N/mm
2
fyp 1478.26 N/mm

Ap

Los autores, 1998; Edicions UPC, 1998.

212

Hormign armado y pretensado. Ejercicios

1884.96

+ 840

1478 .26

434.78
rl =
= 0.0169 < 0.02
400 700
scdp =- 3 N/mm2 (ya calculada antes)
cotgq = cotgqe b = 1
1/ 3
Vcu = 0.10 15345 (100 0.0169 30 )
+ 0.15 3 400 700 1 = 285.02 kN
Vrd = Vcu+Vsu Vsu = 440.1 kN - 285.02 kN = 155.08 kN
Vsu = S Aafyadzsena(cotga+cotgq) = 155.08 kN
a = 90, cotgq= 1.43
3
155.08 10 N
S Aa =
= 0.396 mm 2 / mm
2
434.78 N / mm 0.9 700 mm 1.43

Verificacin:

S Aafyad

1
2

f1cdb0

sen
1

- cos a

= 2400 N / mm
2

Aafyad = 0.396 mm /mm434.78 N/mm = 172.17 N/mm


Armadura mnima:

0.20 ck + 0.75 b = 180 N / mm


20

172.17 N/mm < 180 N/mm


no cumple.

A a f ya d

sen

Disponemos de armadura mnima.

S Aafyad = 180 N/mm2


Aa =

180 N / mm

434.78 N / mm

= 0.414 mm 2 / mm
2

Aa = 0.414 mm /mm = 4.14 mm /cm

p f2 2 p f2
2
2
=
( mm / mm cm )
4 Aa
4 4.14
2
St = 0.379
10 mm St = 37 cm
20 mm St = 151 cm

St =

Comprobaciones:
1
5
2
3

Vu1

= 284.04 kN

Vu1

= 946.8 kN

Vrd = 440.1 kN

Los autores, 1998; Edicions UPC, 1998.

se cumple

E.L.U. de agotamiento por solicitaciones tangenciales

St 0.60 d = 0.60700 mm = 420 mm < 300 mm


10 cada 30 cm estoy disponiendo ms armaduras.
2
2
2pf
2 p 10
10 Aa =
=
= 0.5236 mm 2 / mm = 5.24 mm 2 / cm
4 St
4 300

Los autores, 1998; Edicions UPC, 1998.

213

215

E.L.U. agotamiento por solicitaciones tangenciales

Ejercicio II-7 Cortante en vigas de hormign pretensado con armaduras postesas

El tablero de un pantaln de 6 m de anchura, est constituido por vigas de 20 m de luz, de seccin


en T, simplemente apoyadas, de hormign pretensado con armaduras postesas, como indica la
figura adjunta.

20

Las vigas se prefabrican junto a la obra, donde se postesan, y se montan despus en su posicin
definitiva, disponiendo superiormente una losa de 10 cm de hormign armado. Se considera un
nivel de control de la ejecucin intenso.
- hormign HP-40/P/20/IIIc, f = 40 N/mm
- armaduras activas Y 1860 S7, f = 1700 N/mm , f = 1860 N/mm
- armaduras pasivas B 500 S, f = 500 N/mm
Las cargas consideradas son:
- peso propio de las vigas y de la losa,
- cargas muertas adicionales 2.0 kN/m ,
- sobrecargas de uso 10 kN/m .
El pretensado de las vigas consiste en 2 tendones de 7 f 0.6 (A =2 980 =1960 mm ), tesados
a 1400 N/mm . El trazado equivalente es parablico, con distancias al fondo de 200 mm y 800 mm
desde el centro de gravedad de los cables, en centro de luz y apoyos, respectivamente. Las vainas
son de 65 mm de dimetro y se inyectan tras el tesado con lechada de cemento. Las prdidas totales
de pretensado se estiman en un 25% de la fuerza en anclajes.
No se precisa armadura pasiva longitudinal por razones de clculo, disponindose la estrictamente
necesaria por razones de construccin, retraccin o temperatura diferencial, sin considerar la
colaboracin resistente de la losa superior.
2

ck

pyk

pn

yk

p,total

Los autores, 1998; Edicions UPC, 1998.

216

Hormign armado y pretensado. Ejercicios

Se pide:

Dimensionar las armaduras transversales en el alma y las alas de la viga, efectuando las
comprobaciones a cortante que correspondan.
Solucin

Valores de clculo de los materiales:


f = 140.5 = 26.67 N mm
f = 1500
.15 = 434.78 N / mm
f = 1700
1.15 = 1478.26 N mm
Acciones y esfuerzos de clculo:
- peso propio g = 0.6 25 = 15 kN/m
- peso losa
g = 0.1 1.5 25 = 3.75 kN/m
- carga muerta g = 2.0 1.5 = 3 kN/m
- total
g = g1 + g2 + g3 = 21.75 kN/m
- sobrecarga q = 10 1.5 = 15 kN/m
Esfuerzo cortante de clculo:
V = 1.35 gl2 + 1.50 ql2 = 293.6 + 225 = 518.6 kN
Fuerza de pretensado a largo plazo:
2

cd

yd

pyd

1
2
3

= Pand 0.75 = 1400 N

mm

1960 mm 2 0.75 10 -3 = 2058 kN

1 Dimensionamiento de la arm adura transversal en el alma

Si la suma de los dimetros de las vainas es superior a b/6, el ancho del alma a efecto de cortante se
obtiene descontando los huecos de las vainas segn la expresin:
b = b - Sh
0

Los autores, 1998; Edicions UPC, 1998.

217

E.L.U. agotamiento por solicitaciones tangenciales

donde b es la menor anchura del nervio en los inferiores de la parte que corresponde al canto til
de la seccin.
h es un coeficiente que depende de las caractersticas de la armadura y vale h=0.5 para barras y
vainas con tendones adherentes

hf = 65 mm
b 200 - 65 = 135 mm
Por efecto de la inclinacin de los tendones de pretensado, el cortante de clculo se reduce segn:
V = V - P sen a
La pendiente de los tendones en anclaje es:
tg a = 0.12 , con lo que sen a = 0.1192 y por tanto
V = 518.6 - 2058 0.1192 = 273.3 kN
0

rd

rd

1.1 Obtencin de Vu1 :

ngulo de inclinacin de las bielas, cotgq. Se adopta:


cot gq = cot gq = 1 - fs = 1 + 33..43
51 = 1.41
P
2058 = -3430 kN m = -3.43 N mm
s =- =A
0.6
xd

ctim.

xd

f ct, m

= 0.30 3 f k2 = 0.30 3

40

= 3.51 N

mm

Considerando nicamente armadura vertical (cercos), a = 90 y siendo el brazo mecnico z = 0.9


d = 0.9 1.15 = 1.035 m, se obtiene:
V = K f b z ctogq + cot ga = 0.6 26.67 135 1035 12..41
99 = 1054.4 kN
1 + cot g q
u1

1cd

El factor k se obtiene de la expresin:


k = 53 1 + sf

'

cd

cd

<1

donde s es una tensin media axial cuyo valor es:


cd

Los autores, 1998; Edicions UPC, 1998.

218

Hormign armado y pretensado. Ejercicios

N + A' s
A

s'cd =

sd

Para el caso que nos ocupa, N es el axil de clculo debido al pretensado final, con coeficiente de
mayoracin g = 1.0, por tratarse de estado lmite ltimo.
Adems, A = 0 pues se trata de armadura de compresin dispuesta por montaje pero no necesaria
por clculo. Por tanto en este caso s = s = - 3.43 N/mm .
k = 53 1 - 263..4367 = 1.45 > 1 k = 1.

Se cumple por tanto que V < V , siendo:


1 V = 210.9 < V < 2 V = 702.9 kN .
5
3
d

cd

rd

u1

xd

u1

rd

u1

1.2 Obtencin de Vu2 y Vcu

cu

(0.10 x (100r f
1

1/ 3

ck

- 0.15 s'cd b 0 d b

200 = 1 + 200 = 232


d
115
f
A + A f 1960 1700
500
r =
b d = 135 1150 = 0.0429
2 cot gq - 1 = 1 pues q = q
b=
2 cot gq - 1
V = (0.10 2.32 (100 0.0429 40 ) + 0.15 3.43) 135 1150 = 280028 N = 280 kN
x =1+

pyd

yd

1/ 3

cu

Como V > V , slo har falta armadura mnima en esa seccin.


A f
f

40

sen a 0.20 20 + 0.75 b = 0.20 20 + 0.75 135 = 74.25 N / m


A = 74.25 N / mm = 0.171 mm / mm = 171 mm / ml
434.78 N / mm
cu

rd

s, min

yd

ck

s, min

Disponiendo estribos f6 (2 ramas), A = 2 28.3 mm =56.6 mm separados 300 mm se tiene:


A = 2 28.3 1000
300 = 188.67 mm ml > 171 mm ml .
2

Los autores, 1998; Edicions UPC, 1998.

219

E.L.U. agotamiento por solicitaciones tangenciales

Esta disposicin cumple con la separacin mxima establecida (300 mm).


1.3 Otras secciones a lo largo de la pieza

En otras secciones, dado que el trabado del tendn equivalente es parablico, el efecto favorable del
pretensado (P sena) disminuye, aunque tambin lo hace el cortante exterior.
Por ello es preciso verificar que en ningn punto V supera el cortante resistido por el hormign V
pues de lo contrario habra que disponer armadura superior a la mnima.
La ley de esfuerzos cortantes de clculo es:
rd

Vg =

Vq =

gl
2

q
2l

cu

-gx = 217-21.75x

2
2
(l-x) = 0.375(20-x)

Vd = 1.35Vg+1.5Vq
= 518.6-51.7x+0.5625x

Reduccin del cortante:


Para ello hay que conocer el valor de sena a lo largo de la pieza. Dado que a es muy pequeo, se
identifica con tga=e(x) siendo e(x) el trazado del tendn equivalente de pretensado, cuya expresin
es:
e'(x ) = tg a = 0.012x - 0.12 ; P sen a 24.696 x - 246.96
con lo que:
Vrd

= Vd - P sen a = 271.6 - 27 x + 0.5625 x 2

Haciendo V = V se obtendra x = 24 m., o bien, x<0, con lo que nunca se alcanza este valor.
Por tanto se dispone armadura mnima en toda la pieza, consistente en cercos f6 cada 30 cm.
rd

cu

Los autores, 1998; Edicions UPC, 1998.

220

Hormign armado y pretensado. Ejercicios

2 Armadura transversal de las alas

Estar compuesta por la mayor de las armaduras debidas a flexin transversal y al rasante en la
unin alas-alma (artculo 44.2.3.5, EHE)
2.1 Armadura debida a flexin t ransversal.

El momento de clculo ser el correspondiente a un voladizo de 0.55 m. de luz. El clculo se


realiza por metro de ancho.
M = p 2l = (1.35 g + 1.50 q ) 0.55
2 = 5.22 kN m ml
g = g 1.5 = 14.5 kN / m
q = 10 kN m
A = 08f U 1 - 1 - 0.852 MU d = 100.32 mm ml < A mm

A f = 0.04 U = 0.04 26.67 1000 160 = 170688N


A
= 392.6 mm ml
2

st

yd

s, min

yd

s, min

2.2 Rasante en la unin alas-alm a

Si se considera el equilibrio del ala aislada en una longitud de viga a , necesariamente debe aparecer
una fuerza en la unin alas-alma como indica la figura adjunta.
r

Aproximadamente se puede tomar:


b - b = DM b - b
DF = DN
2b
z 2b
en donde (b - b )/2 es el vuelo del ala.
w

Los autores, 1998; Edicions UPC, 1998.

221

E.L.U. agotamiento por solicitaciones tangenciales

Se admite que existe una redistribucin plstica de tensiones rasantes en una cierta longitud a
siempre que en ella la ley de momento sea montona creciente o decreciente, siendo entonces el
esfuerzo rasante (S ) por unidad de longitud, el valor medio de la fuerza DF en a , es decir:
S = DaF = zDM a b 2- bb
r

Ahora bien, en el caso de piezas pretensadas, en el valor de DM debe incluirse tambin la variacin
del momento debido al pretensado, que en esta pieza isosttica es (P De), con lo cual se tiene:
S = DM z + aP De b -2bb
d

En el caso que nos ocupa, se adopta para a la mitad de la viga (a =l/2), siendo De=0.6 m
r

DM d = (M d ) l - (M d )0 = M d
2

(l 2 )= (1.35 g + 1.5 q ) l8 = 2593 kN m


2

- 2058 0.6 1.5 - 0.4


S = 2593
0.9 1.15 10 2 1.5 = 48.12 kN m
Las armaduras transversales necesarias se obtienen mediante el mtodo de las bielas y tirantes,
segn se indica a continuacin.
sen q = S tg q = S ; A = 111 mm ml
T = C sen
sen a
a
S = T = A f a
d

y d

Armadura
transversal

a = 90
Unin

alas-alma

T
Alma

aJ
Sd

C cos
T sen
Fisuracin

Vista en planta

Verificacin de la compresin oblicua


S S = 0.5 f h
d

41

1cd

donde:

Los autores, 1998; Edicions UPC, 1998.

J = Sd
a = C sen J

222

Hormign armado y pretensado. Ejercicios

f = 0.60 f = 16 N/mm (para el ala comprimida)


h = profundidad del ala = 0.20 m= 200 mm.
Vemos que cumple.
Por lo tanto, la armadura necesaria ser 392.6 mm /ml que es la mayor entre la debida a la flexin
de las alas y la de rasante.
1c,d

cd

3 Disposicin de armaduras

Para facilitar la construccin, conviene que las armaduras del alma y la de las alas estn dispuestas a
la misma distancia o con separaciones proporcionales. Dado que la A del alma consiste en cercos
f6 cada 30 cm (A = 333 mm /ml).
Se propone disponer cercos f10 cada 15 en las alas, que proporcionan una armadura superior de
st

st

100 = 523.6 mm ml
4
4 15
y si se desea apurar ms, a coste de complicar la ejecucin, podran disponerse f10 cada 30 + f6
cada 30 alternados.
A

s sup

p f2

100 =

p 10 2

cercos 10 cada 15 cm
cercos 6 cada 30 cm

Los autores, 1998; Edicions UPC, 1998.

223

E.L.U. de agotamiento por solicitaciones tangenciales

Ejercicio II-8 Torsin en una viga de hormign armado


Una marquesina de hormign armado est constituida por una viga rectangular de 0,50 x 0,80 m y
una losa de 0,20 m de espesor que vuela lateralmente 1,50 m como indica la figura adjunta. La
viga, de 8 m de longitud, se encuentra biapoyada a flexin y empotrada a torsin en sus extremos.
2

Las acciones a considerar, adems del peso propio, son una sobrecarga variable de 4 kN/m
extendida en cualquier posicin sobre la Marquesina.
Las caractersticas de los materiales son:
2

- hormign

HA-25/P/20/IIb fck = 25 N/mm

- armaduras pasivas: barras corrugadas de acero B-500-S.

Se pide
Dimensionar a flexin, cortante y torsin todas las armaduras, y efectuar las comprobaciones
necesarias frente a estos estados lmite ltimos.

Solucin
1 Resistencias de clculo de los materiales
f cd

f yd

f ck
1,5
f yk
1,15

25
1,5

N mm

500
1,15

N mm

= 16,67 N
2

mm

= 434.78 N

mm

2 Consideraciones geomtricas y de clculo general


- se dispondrn las armaduras longitudinales con un recubrimiento mecnico de 50 mm.

Los autores, 1998; Edicions UPC, 1998.

224

Hormign armado y pretensado. Ejercicios

- se supone que la torsin ser resistida por la seccin de la viga, nicamente.


- se considera el control de ejecucin intenso, siendo entonces

fg

= 1,35 y

fq

= 1,50.

3 Esfuerzos de clculo

= 0.8 0.5 25 = 10 kN ml
g PL = 0.2 1.5 25 = 7.5 kN ml
1.50

m tl = g PL
+ 0.25 = 7.5 kN m
2

2
q = 4 kN m 1.75 = 7.0 kN ml
m q = q 0.875 = 6.125 kN m ml
g PV

- peso propio viga


- peso propio losa
- momento mutano
- sobrecarga
- momento muntano

ml

Momento flector mximo

Md

= 1.35 g

+ 1.50 q

= 273 kN m

Esfuerzo cortante mximo

Vd

= 1.35

gl
2

+ 1.50

ql
2

= 136.5 kN

Momento torsor mximo

Td

= 1.35 m tl

l
2

+ 1.50 m q

l
2

= 77.25 kN m

Las leyes de esfuerzos son las de la figura (envolventes, con

fg

= 1,35,

Los autores, 1998; Edicions UPC, 1998.

fq

= 1,50)

225

E.L.U. de agotamiento por solicitaciones tangenciales

273 kN.m
136.5 kN

10.5
77.25 kN

136.5 kN

9.18 kN.m
77.25 kN

4 Dimensionamiento a flexin
uc

uc

= f cd b d = 16.67 500 750 10 -3 = 6251.25 kN


d = 6251.25 0.75 = 4688.44 kN m

M lim

As

As

= 0.319 u c d = 1495.61 kN m > M d A's = 0

2M d
= 377.4 kN
f yd = 0.85 u c 1 - 1 0.85 u c d

3
377.4 10 N
=
= 868 mm 2 3f20 (en principio )
2
434.78 N mm

5 Dimensionamiento a cortante

= 0.10 x (100 r l fck )

q = 45 b = 1
b 0 = 500 mm
d = 750 mm
Vcu

200

x =1+
rl =
Vcu
Vsu
As

As
b0

- s'cd 0.15 b 0 d b

= 1.516
868
500

750

= 0.00231

= 0.10 1.516 (100 0.00231 25 ) 3 500 750 10 -3 = 102 kN


= Vd - Vcu = 136.5 - 102 = 34.5 kN
1

Vsu
0.9

f yd d

34500
0.9

434.78 750

= 0,1176

mm

mm

Los autores, 1998; Edicions UPC, 1998.

= 117,6

mm

ml

226

Hormign armado y pretensado. Ejercicios

0.20
A s, min

ck + 0.75 b
20

= 0.46
f yd

mm

mm

= 460

mm

ml

6 Dimensionamiento a torsin
Tu1

= a f1cd A e h e

cot gq
+ cot g 2 q

Espesor de la seccin hueca eficaz,

he

A
u

Por tanto se adopta

Ae

he

800
= 153.85 mm
2 (500 + 800 )
500

< h 0 (no procede )

> 2c = 100 mm

he = 2 c = 100 mm.

= (h - h e ) (b - h e ) = 700 400 = 280000 mm 2 = 0.28 m 2

a = 1.2 (pues se colocar una sola carga de cercos, junto al permetro exterior).
25

f1cd

= 0.60 f cd = 0.6

Tu1

= 1.2 10 0.28 10 6 100

1.5

= 10 N
1
2

mm

10 - 6 = 168 kN m

= 77.25 kN m < Tu1 = 168 kN m


A st f td
T
77.25 1
d tg q =
= 137.95 kN / m
st
2A e
2 0.28

Td

A st

317.29 mm 2

st
A sl

ftd
u

Td
2A e

ml

cot gq = 137.95

A sl
u

= 137,29 mm 2

ml

En las caras superior e inferior Asl = 69 mm y en las caras laterales 110 mm .

7 Armaduras necesarias
Armadura longitudinal
Se dispondr toda la armadura constante a lo largo de la pieza, y sta consistir en la superposicin
de la armadura de flexin y de torsin.

Los autores, 1998; Edicions UPC, 1998.

227

E.L.U. de agotamiento por solicitaciones tangenciales

A s ,sup= 69 mm 2
110 mm 2

69 mm 2

A s lat = 110 mm 2
69 mm 2
A s =868 mm 2

A s ,inf = 937 mm 2

FLEXION

TORSION

Armadura transversal
Por esfuerzo cortante Astc
utilizan cercos

nc

117.6 mm /ml, y por torsin hacen falta Astt

f8 hacen falta (Af = 50 mm ).

317.29 mm /ml. Si se

A stc

+ nt =

2Af

Si se utilizan cercos

nc

A stt

117.6

2 50

317.29
50

= 7.52 cer cos

ml

(f8 cada 12.5 cm )

f10 (Af = 78,54 mm )


2

117.6

+ nt =

Af

78.54

317.29
78.54

= 4.78 cer cos

ml

(f10 cada

20 cm )

Esta ltima disposicin parece ms razonable.

8 Comprobaciones
Armadura mnima de cortante

f yd
f

0.20 ck + 0.7 b = 200 N mm


sen a
20

A s, min f yd
n
A
2 78.54
= ramas f f yd =
434.78 = 342 N
sen a
st
200

A s, min

mm

> 200

luego cumple

Separacin entre cercos, segn cortante

Vu1

Vd

= k f1cd b 0 z
<

1
5

Vu1

25
1
q + cot ga
= 0.6
500 0.9 750 10 - 3 = 1687.5 kN
1.5
2
+ cot g 2 q

cot g

s t = 200

mm

< 0.80

< 300

mm

luego cumple

Los autores, 1998; Edicions UPC, 1998.

228

Hormign armado y pretensado. Ejercicios

Separacin entre cercos, segn torsin

St

ue

St

2200

Tu1

; u e = Permetro seccin eficaz = 2 (700+400) = 2200 mm.

= 275 mm

= 168 kN m ;

Por tanto

como St = 200 mm < 275

Tu1

Td

2
3

Tu1

0,6 a < 300 mm.


240 mm.

St
St

luego cumple.

a = 400 mm.
luego cumple

Verificacin de la compresin en las bielas de hormign

Vd Td

+
1
Vu1 Tu1
h

b = 2 1 - e = 2 1 b

1 .6

1 .6

136.5

1687.5

77.25
+

168

(Interaccin torsin-cortante)

0.1
0.5

= 1.6

= 0.306 < 1

luego cumple

Torsin combinada con flexin y axil


Hay que calcular la tensin principal de compresin

s md

s cd =

donde

t td

cd

<

af

1cd

= 12 N/mm .

s
+ md + t 2td
2
2

s md

Md
I

, en la seccin de clculo.

Td
2A e

he

Como no son coincidentes las secciones con mximos momento flector y torsor, debera realizarse
la verificacin en ambas. No obstante, verificamos el caso ms desfavorable que sera Md = Md
= 273 kNm y Td = Td mx. = 77.25 kN/m.
En tal caso se tendra:

Los autores, 1998; Edicions UPC, 1998.

mx.

229

E.L.U. de agotamiento por solicitaciones tangenciales

s md =

= 5518.7 kN
0.5

273 0.4
0.8

= 5.52 N

mm

12

t td =
s cd =

77.25
2

0 28 0.10

5.52
2

= 1379.5 kN

= 1.38 N

mm

5.52
+
+ 1.38 2 = 5.85 N
2

mm

< 12 N

mm

luego cumple

9 Disposicin de armaduras:

Longitudinalmente, la solucin ms econmica consistira en disponer la malla electrosoldada en


toda la pieza y complementar con las barras longitudinales. En zonas donde no es estrictamente
necesaria, queda compensado por la simplicidad de construccin. No obstante, podra reducirse la
armadura transversal bien aumentando la separacin entre cercos, bien disminuyendo el dimetro de
stos, bien variando ambos. Optando por la ltima opcin se decide colocar en la zona central de la
viga cercos

f8

cada 25 cm. Se trata de buscar el punto donde la ley de momentos torsores corta al

torsor resistido Tu2.

Los autores, 1998; Edicions UPC, 1998.

230

Hormign armado y pretensado. Ejercicios

Tu 2

A st

f td

St

50

2 A e tg q =

434.7
250

2 280000 1 = 48.7 10 6

kN

La ley de momentos torsores tiene la ecuacin

Td (x) = 48.7

x = 1,55 m.

Por tanto se dispondrn cercos

f8 cada 25 cm. a partir de

= 1.55 +

h
2

2.00 m .

Justificacin del armado de los voladizos:


Dado que el voladizo no se ha hecho participar como elemento resistente longitudinal, el armado se
plantear transversalmente para resistir la flexin del vuelo, y longitudinalmente para prever
flexiones locales. Por unidad de longitud se tiene

= 1.35 g

M dt
M lim

U s1

Se disponen

lt

+ 1.50 q

lt

= 7,59 + 6.75 = 14.34 kN m

= 0.319 16.67 1000 150 2 10 -6 = 119.65 > M d

= 0.85 u c 1

2M d
0.85

uc

= 97.85 kN
d

As = 225 mm /ml.

f8 cada 20 cm, transversalmente y f6 cada 30 cm (u 0.25 u


s2

Los autores, 1998; Edicions UPC, 1998.

s1

).

231

E.L.U. de agotamiento por solicitaciones tangenciales

Ejercicio II-9 Torsin en una viga de hormign armado embrochalada

Considrese la estructura de la figura adjunta, constituida por dos vigas embrochaladas de hormign
armado, de igual seccin rectangular, tal como indica la figura adjunta. La viga CD se encuentra
apoyada a flexin y empotrada a torsin en ambos extremos, mientras que la viga AB se encuentra
simplemente apoyada en A y empotrada a la viga CD en su punto medio.
Las propiedades de proyecto de los materiales son:
- hormign: HA-30/P/20/I, f = 30 MPa,
- armaduras: Barras corrugadas de acero B 500 S, f = 500 MPa
Se considera un nivel de control normal.
c,k

y,k

Se pide:

1. Dimensionar las armaduras necesarias a flexin, cortante y torsin de las secciones crticas de
ambas vigas en los siguientes supuestos:
a) se considera la rigidez integra (sin fisurar) a torsin de la viga CD
b) se desprecia la rigidez a torsin de la viga CD
Se recomienda utilizar barras de dimetros 16 y 20 mm para armaduras longitudinales
principales, dimetros 8, 10 y 12 para armaduras transversales, dimetros 10 y 12 para armaduras
longitudinales de montaje y dimetros 5 y 6 mm para armaduras de piel.
Se despreciar la accin del peso propio.
Nota:

Los autores, 1998; Edicions UPC, 1998.

232

Hormign armado y pretensado. Ejercicios

Solucin
1. Dimensionamiento considerando la rigidez a torsin de la viga CD

Al considerar la rigidez ntegra a torsin de la viga CD, se transmite un momento entre las dos
vigas, siendo en el tramo AB un momento flector y en el CD un momento torsor.
Para hallar el momento en la unin se impone la compatibilidad de giros en dicha seccin, segn
ambas estructuras.
Ml P l d
3 E I + 16 E I - l
RL
=
48 E I
ML
=
2GI
2

j =I

II
B

II
B

II
B

Imponiendo que la compatibilidad de giros en la unin (j = j ) y el equilibrio ( R = P2 + Ml ), se


obtienen una expresin para el momento transmitido:
I

II

P 16l - 96L l
M = L E I l L
2 G I + 3 + 48 l
En el caso particular de este ejercicio, los valores que se toman son:
L = 8000 mm
l = 6000 mm
I = 7.210 mm
I = bhb = 7.5310 mm
(h/b = 1.5 b = 0.196)
E = 8500f = 28577 MPa
n = 0.2
G = 2 (1E+ n) = 11907 MPa
P = 200000 N
M = 54692810 Nmm @ 54.7 kNm
R = 109110 N = 109.11 kN
2

1/3
cm

Los autores, 1998; Edicions UPC, 1998.

233

E.L.U. de agotamiento por solicitaciones tangenciales

Entonces las leyes de esfuerzos que han de considerarse son las siguientes:

Considerando un coeficiente de seguridad g = 1.6, los valores de clculo en las secciones crticas
son:
Q

Seccin
M (kNm)
V (kN)
T (kNm)

1
436.22
174.58
0

2
87.50
174.58
0

1.1 Dimensionamiento a flexin

Seccin 1
M = 436.22 kNm
M = 0.319f bd = 771.9810 Nmm > M A = 0
f = 30/1.5 = 20 MPa
d = 550 mm
U = 0.85 f b d 1 - 1 - 0.852 f M b d = 901865 N

A = Uf = 2074 mm
d

lim

cd

cd

s1

cd

cd

s1

yd

Los autores, 1998; Edicions UPC, 1998.

3
349.15
87.28
43.76

4
0
87.28
43.76

234

Hormign armado y pretensado. Ejercicios

f = 434.78 MPa
1.15
La armadura mnima que hay que disponer en cualquier caso es la mayor de:
A 0.04 A f f = 404.6 mm
A 0.0028 A = 0.0028 400 600 = 672mm
f

yd

yk

cd

s,min

yd

s,min

Se dispone, pues, A = 2074 mm (r = 0.009) en la cara inferior.


Seccin 2
M = - 87.5 kNm
M = 771.9810 Nmm > M A = 0
U = 162626 N
A = 374 mm
En la cara superior se dispondr armadura mnima A = 672 mm , mientras que en la inferior se ha
de colocar una armadura tal que resista la tercera parte de la necesaria en la seccin crtica (1) A
= 631 mm .
Seccin 3
M = 349.15 kNm
M = 771.9810 Nmm > M A = 0
U = 700401 N
A = 1610 mm (r = 0.00073), dispuesta en la cara inferior.
Seccin 4
M = 48.0 kNm (desplazando la ley de momentos flectores un canto til)
M = 771.9810 Nmm > M A = 0
U = 88330 N
A = 203 mm .
En la cara inferior se dispondr armadura mnima A = 672 mm , que es superior a la tercera parte
de la necesaria en la seccin crtica (3) de la viga en cuestin: A = 477 mm .
Estas armaduras longitudinales debidas a flexin se compondrn adecuadamente con las
longitudinales necesarias por torsin.
2

lim

s1

lim

s1

lim

s1

1.2 Dimensionamiento a cortante

En cualquier seccin el esfuerzo de agotamiento por compresin del alma es:

Los autores, 1998; Edicions UPC, 1998.

235

E.L.U. de agotamiento por solicitaciones tangenciales

V = 0.45Kf b d = 1188 kN > V


f = 0.60f = 12 MPa
K1
Por lo que se refiere al esfuerzo de agotamiento por traccin del alma, el trmino correspondiente a
la contribucin del hormign se obtiene mediante la siguiente expresin:
V = 0.10x(100r f ) b d = 508624r
200 = 1.603
x =1+
d
u1

1cd

1cd

cd

cu

ck

1/3

1/3

La armadura transversal necesaria se obtiene imponiendo: V = V = V + V ,, teniendo en


cuenta que V = A f 0.9d. As pues, el rea de armadura transversal por unidad de longitud
se determina mediante la siguiente expresin:
-V
(en mm /mm)
A = V198000
habiendo considerado f = 400 MPa.
En cualquier caso, se dispondr una armadura mnima de valor:
A a = 0.20 f20 + 0.75 f b = 0.45 mm /mm = 4.5 cm /m

a
f a = 400 MPa
Seccin 1
V = 174.58 kN
r = 0.009 V = 105.80 kN
A = 3.4 cm /m
Se dispone armadura transversal mnima: 4.5 cm /m.
Seccin 2
V = 174.58 kN
r = 0.003 V = 73.36 kN
A = 5.1 cm /m, que es superior a la armadura mnima.
Seccin 3
V = 87.28 kN
r = 0.007 V = 97.30 kN
Dado que V < V se dispondr armadura mnima A = 4.5 cm /m.
d

su

90

u2

su

y90,d

cu

90

y90,d

ck

,min

y ,d

y ,d

cu

90

cu

90

cu

cu

90

Los autores, 1998; Edicions UPC, 1998.

cu

236

Hormign armado y pretensado. Ejercicios

Seccin 4
V = 87.28 kN
r = 0.003 V = 73.36 kN
A = 0.7 cm /m, que es inferior a la mnima, habindose de disponer por lo tanto 4.5
cm /m.
Esta armadura transversal debida a cortante se ha de sumar convenientemente con la que resulte del
clculo a torsin.
d

cu

90

1.3 Dimensionamiento a torsin de la viga CD

El espesor ficticio que se adopta para la seccin es:


h = Au = 120 mm
A = 600400 = 240000 mm
u = 2(400+600) = 2000 mm
Este valor de h , determina los siguientes valores de A y u :
A = 134400 mm
u = 1520 mm
El esfuerzo de agotamiento de las bielas comprimidas se evala como:
T = 0.5af A h = 116.12 kNm
a = 1.20, considerando que se disponen los estribos nicamente a lo largo del permetro
exterior de la pieza
f = 0.60f = 12 Mpa
que es mayor que T = 43.76 kNm, en cualquier seccin.
Las armaduras transversales han de resistir el siguiente esfuerzo torsor:
T = 2 As A f = T
e

u1

1cd

1cd

cd

u2

yt ,d

de donde, considerando f = 400 MPa, se obtiene que:


A = 4.07 cm /m
s
yt,d

Por otra parte, la armadura longitudinal ha de resistir un esfuerzo igual a:

Los autores, 1998; Edicions UPC, 1998.

237

E.L.U. de agotamiento por solicitaciones tangenciales

u3

2A A f
u

=T

yl,d

Adoptando un valor f = 400 MPa, el rea de las armaduras longitudinales que es necesaria es:
A = 619 mm
que se ha de disponer a lo largo del permetro de la seccin.
yl,d

Interaccin torsin - solicitaciones normales


Adoptando el mtodo simplificado, se ha de comprobar que:
s af
en una fibra situada en el plano medio de la seccin hueca eficaz, esto es en
h
-h
z = 2 = 240mm
donde:
cd

1cd

s =

cd

s
+
2

md

md

+ t

2
td

= 11.78

MPa

h = 11.63 MPa
I 2
T
t =
2 A h = 1.35 MPa
af = 1.212 = 14.4 MPa
As pues, se satisface esta condicin de no agotamiento.
s

md,max

d,max

td

1cd

Interaccin torsin - esfuerzo cortante


En este caso se ha de comprobar que:
T

V
+
V
h
b = 2 1 b

u1

u1

43760000

116120000

= 1.4

1.4

87280
+

1188000

1.4

= 0.281 < 1

Los autores, 1998; Edicions UPC, 1998.

238

Hormign armado y pretensado. Ejercicios

Tambin en este caso se satisface la condicin de no agotamiento de la seccin.


Seguidamente se procede a la determinacin de la armadura longitudinal y transversal que se
dispondr en las secciones crticas.
A la hora de sumar la armadura transversal, se ha de tener en cuenta que la armadura necesaria por
cortante se refiere al nmero de ramas que se disponen, que en este caso, al disponer cercos, son
dos. Por su parte, la armadura transversal que se necesita para hacer frente a la torsin nicamente
cuenta por una rama, pese a disponerse un cerco cerrado. As pues, en las secciones 3 y 4 es
necesario disponer un cerco cerrado de seccin la suma de 4.5/2=2.25 cm /ml (cortante) y 4.07
cm /ml (torsin), es decir, 6.32 cm /ml por rama. Ello requiere un f12 cada 17.8 cm, por lo que se
dispondrn f12 cada 15 cm, esto es un total de 7.54 cm /ml.
En las secciones 1 y 2, donde no hay torsin, solo se dispondrn cercos por cortante igualmente
distribuidos en toda la longitud de la viga AB. El rea necesaria es la mnima, esto es 4.5 cm /ml
que equivale a disponer cercos f12 cada 25 cm.
En cuanto a la armadura longitudinal, la debida a torsin debe repartirse uniformemente en el
permetro, y la de flexin debe disponerse en la zona traccionada. De esta forma se tienen los
siguientes esquemas de armado:
2

Los autores, 1998; Edicions UPC, 1998.

239

E.L.U. de agotamiento por solicitaciones tangenciales

2 Dimensionamiento despreciando la rigidez a torsin de la viga CD

En este caso, al despreciar la rigidez a torsin de la viga CD frente a la rigidez a flexin de la viga
AB, no se transmiten momentos en la unin de ambos elementos, por lo que se pueden calcular
como vigas simplemente apoyadas.

Las leyes de esfuerzos (momento flector y cortante) son en este caso:

Los valores de clculo que se adoptan para el dimensionamiento de las secciones crticas son:
Seccin
1
2
3
4
M (kNm)
480
0
320
0
V (kN)
160
160
80
80
d

2.1 Dimensionamiento a flexin


Seccin 1
M = 480 kNm
M =771.9810 Nmm > M
U = 10087731 N
A = 2321 mm (r = 0.011)
d

lim

A = 0
s

s1

Los autores, 1998; Edicions UPC, 1998.

240

Hormign armado y pretensado. Ejercicios

que es superior a la mnima (A = 672 mm )


Seccin 2
M = 88 kNm (decalando la ley de momentos flectores un canto til)
M = 771.9810 Nmm > M A = 0
U = 163577 N
A = 376 mm
Se dispone entonces la armadura necesaria para resistir un momento flector igual a la tercera parte
del actuante en la seccin crtica (1): A = 698 mm (r = 0.0032), puesto que sta es superior al
0.28% del rea de la seccin de hormign.
Seccin 3
M = 320 kNm
M = 771.9810 Nmm > M A = 0
U = 635873 N
A = 1463 mm (r = 0.0067)
Seccin 4
M = 44 kNm (desplazando la ley de momentos flectores un canto til)
M = 771.9810 Nmm > M A = 0
U = 80875 N
A = 186 mm
Se dispone entonces armadura longitudinal mnima, que en este caso es del 0.28% sobre la seccin
de hormign: A = 672 mm (r = 0.003).
2

s,min

lim

s1

lim

s1

lim

s1

2.2 Dimensionamiento a cortante


En la verificacin a cortante, se mantienen las mismas expresiones que se consideran en el caso a).
El esfuerzo de agotamiento por compresin del alma es:
V = 1188 kN
que sigue siendo superior al cortante de clculo de cualquier seccin.
El trmino correspondiente a la contribucin del hormign a la resistencia a traccin del alma es:
V = 508624r
La armadura transversal necesaria viene dada por la expresin:
u1

cu

1/3

Los autores, 1998; Edicions UPC, 1998.

241

E.L.U. de agotamiento por solicitaciones tangenciales

V - V (en mm /mm)
198000
Finalmente, la armadura transversal mnima es Aa = 4.5 cm /m
Seccin 1
V = 160 kN
r = 0.011 V = 113.12 kN
A = 2.4 cm /m
Por lo tanto, se dispone armadura transversal mnima: 4.5 cm /m
Seccin 2
V = 160 kN
r = 0.0032 V = 74.95 kN
A = 4.3 cm /m
Por lo tanto, se dispone armadura transversal mnima: 4.5 cm /m
Seccin 3
V = 80 kN
r = 0.0067 V = 95.89 kN
Se dispone armadura mnima dado que la contribucin del hormign a la resistencia a traccin del
alma es superior al cortante de clculo.
Seccin 4
V = 80 kN
r = 0.003 V = 73.36 kN
A = 0.34 cm /m
Se dispone armadura transversal mnima.
Para determinar la armadura real que se dispone en cada cara de la seccin se procede de forma
anloga a la que se sigui anteriormente en el caso de considerar la rigidez ntegra a torsin de la
viga CD.
A

90

cu

,min

cu

90

cu

90

cu

cu

90

Los autores, 1998; Edicions UPC, 1998.

242

Hormign armado y pretensado. Ejercicios

Los autores, 1998; Edicions UPC, 1998.

243

E.L.U. de agotamiento por solicitaciones tangenciales

Ejercicio II-10 Torsin en una viga de hormign pretensado


Un puente de hormign pretensado presenta el esquema longitudinal y transversal que se indica en
la figura adjunta.

En los soportes intermedios B y C los apoyos son nicos de forma que permiten el giro de torsin,
mientras que en los estribos se disponen 2 apoyos separados 4.0 m para absorber el par torsor.
El hormign es HP-40/P/20/II, las armaduras pasivas son de acero B-500 S y las de pretensado son
de acero Y1860 S7, de fpyk = 1700 MPa y fpmx = 1860 MPa.
Las cargas actuantes son:

- peso propio (

= 25 kN/m )
2

- cargas muertas: 2.5 kN/m

- sobrecargas repartida: 4.0 kN/m en cualquier extensin


- carga puntual de 600 kN con excentricidad mxima de 3 m respecto del plano medio
Se supone un nivel de control intenso.
El puente va pretensado con 6 tendones de 19 cordones

f0.6 cada uno, cuyo trazado equivalente es

el de la figura adjunta.

Los autores, 1998; Edicions UPC, 1998.

244

Hormign armado y pretensado. Ejercicios

Se pide:
1. Dimensionar las armaduras longitudinales y transversales necesarias para resistir el momento
torsor y el esfuerzo cortante en las secciones de apoyos.
2. Comprobar el estado lmite ltimo de agotamiento por compresin oblicua del hormign bajo
solicitaciones tangentes.
Nota: se tendrn en cuenta el valor diferido de la fuerza de pretensado, puesto que con ste se da la
situacin ms desfavorable. En la siguiente tabla se recoge la fuerza de pretensado y el momento y
cortante hiperestticos de pretensado en las secciones crticas: estribos y pilas.
Estribos

Pilas

Acciones de pretensado
Fuerza de pretensado Pkd (kN)

Vano

Vano

exterior

interior

19442.5

Momento hiperesttico de pretensado Mhip (kNm)

18078.0

Cortante hiperesttico de pretensado Vhip (kN)

2826.5

128.48

128.48

Los momentos flectores que provoca cada accin en las secciones crticas son los que se recogen en
la tabla adjunta.
Estribos

Pilas

Momentos flectores ( kNm)

Vano

Vano

Exterior

interior

Peso propio

Cargas muertas

-19473.7

Sobrecargas repartidas

322.1

-3131.7

Carga puntual

333.2

-1615.2

-1756.0

Los esfuerzos cortantes que provocan las diferentes acciones se observan en la siguiente tabla.
Esfuerzos cortantes ( kN)

Peso propio
Cargas muertas
Sobrecargas repartidas
Carga puntual

Estribos

Pilas
Vano

Vano

Exterior

interior

2164.6

-3934.9

4158.8

195.2

-354.2

375.0

Positivos

521.4

15.1

579.0

Negativos

-73.4

-560.2

-19.6

Positivos

403.9

14.6

648.0

Negativos

-91.6

-582.3

-48.0

Finalmente, suponiendo empotramiento a torsin en estribos y libre el giro a torsin en pilas, los
momentos torsores que se consideran son los que se adjuntan en la tabla.

Los autores, 1998; Edicions UPC, 1998.

245

E.L.U. de agotamiento por solicitaciones tangenciales

Estribos

Pilas

Sobrecarga repartida

Momentos torsores (kNm)

1850

913.51

Carga puntual

1800

1264.86

Solucin
1 Dimensionamiento frente a e sfuerzo cortante
Esfuerzos de clculo.
En primer lugar se calculan los esfuerzos de clculo. Los coeficientes parciales de seguridad que se
consideran, habida cuenta de que el nivel de control es intenso, son
permanentes y

= 1.35 para acciones

= 1.5 para las acciones variables.

En los estribos Vd = 1.35(2164.6 + 195.2) + 1.5(521.4 + 403.9) = 4573.7 kN.


e

Por su parte, en las pilas hay que distinguir entre la zona correspondiente al vano extremo (Vd ) y la
i

zona correspondiente al vano interior (Vd ).


e

Vd = = 1.35(-3934.9 - 354.2) + 1.5(-560.2 -582.3) = -7504.0 kN.


i

Vd = = 1.35(4158.8 + 375.0) + 1.5(579.0 + 648.0) = 7961.1 kN.


Para calcular el esfuerzo cortante reducido de calculo Vrd habr que considerar tanto los esfuerzos
cortantes isosttico como hiperesttico debido al pretensado, siempre con coeficiente de seguridad
igual a 1, por estar en Estado Lmite ltimo.
Estribos: Vrd = 4573.7 + 128.5 + 19442.5(- 0.077) = 3205.1 kN
sen
Pilas:

a tg a = 0.077

Vrd = -7504 +128.5 + 0 = -7375.5 kN


i

Vrd = 7961.1 + 0 + 0 = 7961.1 kN


Por lo tanto, se utilizarn los siguientes valores para el dimensionamiento frente a esfuerzo cortante:
Estribos: Vrd = 3205.1 kN
Pilas: Vrd = 7961.1 kN

2 Dimensionamiento de la arm adura a cortante


En primer lugar se calcula la armadura transversal mnima que hay que disponer en cualquier caso:
Aa

f ya, d 0.20 ck + 0.75 b


20

Los autores, 1998; Edicions UPC, 1998.

246

Hormign armado y pretensado. Ejercicios

Tanto para los estribos como para las pilas, donde hay seccin macizada, se adopta b = 5000 mm,
por lo que:

0.20
Aa

f
ck + 0.75 b
20
=

0.20

f ya,dml

40

+ 0.75 5000
20

= 6.875
400

mm

mm

= 68.75

cm

ml

La armadura que ha de disponerse por clculo se obtiene imponiendo que el cortante efectivo de
clculo sea igual al esfuerzo de agotamiento por traccin del alma. Este ltimo se obtiene como
suma de una contribucin del hormign y otra del acero: Vu2 = Vcu+ Vsu.
La contribucin del hormign se evala como:

r f

Vcu = 0.10 (10

s ]b db.

1/3

ck

- 0.15

cd

Los valores que se consideran en el caso de los estribos son:

200

x =1+

=1+

200

= 1.555

650

Shf = 5000 -60.5100 = 4700 mm

b0 = b - n
Ap

r1

b0

s cd '

Nd
Ac

f pyd
f yd

d
=

2660
4700

-19442500
11090000

1700
500

650

= 0.01776 < 0.02

= -1.753 MPa

Se adopta como valor de la inclinacin de las bielas de compresin cot

1/3

Vcu = 0.101.555(100.017740)

200

=1+

200

= 1.385

1350

b0 = 4700 mm
Ap

r1
s cd '

b0
Nd
Ac

f pyd
f yd

d
=

2660

1700
500

4700 1350

-18078000
11090000

= 0.00855 < 0.02

= -1.630

s xd
f ct , m

+ 0.151.753 50006501 = 1826514 N

Por lo que se refiere a las pilas:

x =1+

q=

MPa

b=1

Los autores, 1998; Edicions UPC, 1998.

b=1.

247

E.L.U. de agotamiento por solicitaciones tangenciales

1/3

Vcu = 0.101.385(100.0085540)

+ 0.151.630 500013501 = 3058886 N

q.

Por lo tanto, haciendo Vu2 = Vrd, Vsu = Vrd - Vcu = A90fy90,d0.9dcot

A 90

- Vcu
0.9 d cot q

Vrd

f y 90, d

En el caso de los estribos:

A 90

- 1826514
= 5.35
400 0.9 650 1.22
3354170

2/3

fct,m = 0.30fck
cot

q=

= 53.5

mm

cm

ml

= 3.51 MPa

Pkd
Ac

mm

f ct, m

19442500

= 1.22

3.51

11090000

Por lo que se refiere a las pilas:

A 90

cot

- 3058886
= 8.34
400 0.9 1350 1.21
7961130

q=

18078000
11090000

3.51

mm

mm

= 83.4

cm

ml

= 1.21
2

As pues, en los estribos se dispone la armadura mnima (68.75 cm /ml), mientras que en las pilas
2

es necesario disponer 83.4 cm /ml.

3 Dimensionamiento a torsin
Esfuerzos de clculo
En este caso nicamente provocan esfuerzos las cargas que pueden ser excntricas respecto del
plano medio de la seccin: sobrecarga repartida y carga puntual. El coeficiente de seguridad que se
considera es

= 1.5.

En los estribos Td = 1.5(1850 + 1800) = 5475 kNm.


En las pilas Td = 1.5(913.5 + 1264.8) = 3267.5 kNm.
Dimensionamiento de las armaduras transversales

El espesor eficaz se estima como h e

A
u

11090000
21331

= 520

mm . Dado que ste valor es superior

al espesor real que hay por encima y por debajo del aligeramiento, en estos casos se adopta este
espesor real he = h0 = 250 mm, tal como se aprecia en la figura.

Los autores, 1998; Edicions UPC, 1998.

248

Hormign armado y pretensado. Ejercicios

Ae = 8648225 mm
ue = 18914 mm

El dimensionamiento se lleva a cabo imponiendo que el esfuerzo de agotamiento por traccin de la


armadura transversal sea igual al esfuerzo torsor de clculo:

Td

= Tu 2 =

At

Ae At

f yt, d cot q

st
Td

st

A e f yt , d cot q

Td

2 8648225

400 cot q
q

En el caso de los estribos Td = 5475 kNm y cot


obtenindose

At
st

= 0.649

mm

mm

= 6.49

cm

Td

691858 10

cot q

= 1.22 (igual que el adoptado para cortante),

ml

En el caso de las pilas Td=3267.5 kNm y cot =1.21, por lo que

At
st

= 0.390

mm
mm

= 3.90

cm

ml

Dimensionamiento de la armadura longitudinal


Imponiendo la igualdad entre el momento torsor de clculo y el esfuerzo de agotamiento por
traccin de la armadura longitudinal:

Td

= Tu 3 =

Al

Ae
ue

A l f yl, d tg q

u e cot q
=
2 A e f yl, d

18914 cot q
=
2 8648225 400

Td

Td

Td

cot q

365791 .5

Se obtienen los siguientes resultados:


2

- estribos: Al = 182.6 cm
2

- pilas: Al = 108.1 cm

A la vista de los resultados obtenidos, se puede plantear disponer la siguiente armadura transversal:
En los estribos:

Los autores, 1998; Edicions UPC, 1998.

249

E.L.U. de agotamiento por solicitaciones tangenciales

- cortante: 2 cercos (4 ramas) de


- torsin: 1 cerco de

f16 cada 10 cm, de rea total 80.4 cm /ml


2

f12 cada 15 cm, con un rea total de 7.53 cm /ml


2

En las pilas:
- cortante: 2 cercos de
- torsin: 1 cerco de

f16 cada 9 cm, de rea total 89.33 cm /ml


2

f12 cada 25 cm, de rea total 4.52 cm /ml


2

4 Comprobacin de la compres in oblicua


Para comprobar el estado lmite ltimo de agotamiento por compresin oblicua del hormign bajo
solicitaciones se han de realizar tres verificaciones: frente a cortante, frente a torsin y la
interaccin entre ambos esfuerzos.
Cortante
Se ha de verificar que:

Vu1

= K f1cd b 0 z

q + cot a
Vrd
+ cot 2 q

cot
1

f1cd = 0.6fcd = 0.626.67 = 16 MPa


b0 = 4700 mm
En los estribos:
z = 0.9d = 0.9650 = 585 mm

Los autores, 1998; Edicions UPC, 1998.

250

Hormign armado y pretensado. Ejercicios

5
3

s '
1 + cd =
f cd

5
3

1.753
1 = 1.557 > 1 K = 1
26.67

q = 1.22

cot

Vu1

= 1 16 4700 585

+0
= 21568172
+ 1.22 2

1.22
1

> Vrd

En las pilas:
z = 0.9d = 0.91350 = 1215 mm

s '
1 + cd =
3
f cd
5

1 3

q = 1.21

cot

Vu1

= 1.564 > 1 K = 1
26.67

= 1 16 4700 1215

1.63

+0
= 44866393
+ 1.212

1.21
1

> Vrd

Torsin
En este caso se ha de verificar que se satisface la siguiente expresin:

Tu1

= a f1cd A e h e

cot
1

+ cot 2 q

Td

Se disponen estribos nicamente en el permetro exterior, por lo que

a = 1.20.

f1cd = 16 MPa
Con estos valores se obtienen los siguientes valores del esfuerzo torsor de agotamiento por
compresin oblicua del hormign:
- estribos: Tu1 = 20352 kNm
- pilas: Tu1 = 20384 kNm
En ambos casos Tu1 es mucho mayor que Td, por lo que no agota la seccin.
Interaccin cortante-torsin
Se considera que

no

se

produce

agotamiento

por

interaccin

comprimidas si se satisface la expresin siguiente:

Td Vrd

+
1
Tu1 Vu1
donde:

Los autores, 1998; Edicions UPC, 1998.

cortante-torsin

en

las

bielas

251

E.L.U. de agotamiento por solicitaciones tangenciales

b = 2 1

he
b

= 2 1

250
5000

= 1.9

Td, Vrd son respectivamente los esfuerzos torsor y cortante efectivo de clculo, que actan
de forma concomitante.
En los estribos la situacin psima se produce con la siguiente combinacin de acciones:

3m

Q
pp+cm+sc

Q
sc

pp+cm

que provoca los siguientes valores de clculo:


Td = 5475 kNm
Vrd = 2814 kNm
1 .9

5475

20352

2814
+

22944

1 .9

= 0.101 1

En las pilas la combinacin que se adopta es:

3m

Q
pp+cm

pp+cm

Q
sc

Td = 3267 kNm
Vrd = 7403.2 kNm
1 .9

3267

20384

1 .9

7403.2
+

47730

= 0.060 1

As pues, se ha visto que no se produce agotamiento por compresin oblicua del hormign bajo
solicitaciones tangentes, verificndose por tanto el estado lmite ltimo.

Los autores, 1998; Edicions UPC, 1998.

253

E.L.U. a cortante-friccin

Ejercicio II-11 Anlisis de secciones de piezas compuestas por varios hormigones.


Cortante friccin
Una losa maciza de hormign armado de 75 cm de canto y 12.80 m de luz libre cubre un
aparcamiento subterrneo existente en la parte central de una plaza donde slo tienen acceso
peatones y vehculos ligeros. La losa est biapoyada en sus extremos y las cargas consideradas en el
proyecto, aparte de su peso propio, fueron:
2

- cargas muertas: pavimento: 1 kN/m ; impermeabilizacin: 0.25 kN/m


2

- sobrecarga de uso: 4 kN/m

La armadura de traccin dispuesta de extremo a extremo es de

f20

cada 10 cm, con un

recubrimiento mecnico de 5 cm.


Se desea transformar la citada plaza en un jardn, para lo cual debe reforzarse la losa frente al
incremento de carga de las tierras. Se propone como solucin recrecer la losa hasta 1 m de canto,
retirando el pavimento y la impermeabilizacin y conectando ambos hormigones adecuadamente con
armadura pasante que se ancla en el hormign en taladros efectuados sobre el mismo. Este
recrecimiento se efecta apeando la losa y, una vez finalizado, restituyendo la impermeabilizacin.
3

Se estima que, adems del peso de las tierras saturadas (de densidad 21 kN/m ), puede actuar una
2

sobrecarga de mantenimiento de 1kN/m .


El hormign de la losa existente es de 25 MPa de resistencia a compresin. Las armaduras son de
acero B 500 S.

Se pide:
1. Calcular la altura de tierras que puede disponerse sobre la losa recrecida
2. Dimensionar la armadura pasante necesaria.

Solucin

1 Clculo de la altura de tierra s:


Para calcular la carga de tierras que puede disponerse sobre la losa recrecida hay que calcular el
momento ltimo resistente de la misma.
Previamente al recrecido, la losa antigua est sometida a un cierto estado tensional cuyo valor no es
necesario conocer, como se ver a continuacin.

Los autores, 1998; Edicions UPC, 1998.

254

Al

Hormign armado y pretensado. Ejercicios

recrecer

con

la

losa

apeada,

cuando

se

desapee,

el

peso

propio

del

recrecido

la

impermeabilizacin ya actan sobre la seccin compuesta. Bajo la accin de las sobrecargas, en


estado lmite ltimo, las tensiones de compresin en la losa antigua se anulan, ya que la fisuracin
profundiza hasta la losa nueva, generando el mecanismo resistente de la figura. Ello equivale a decir
que el momento de clculo es resistido por las compresiones en el hormign nuevo y la traccin de
la armadura existente en la losa antigua.

Suponiendo rotura dctil (que luego se verificar):

0.85 f cd

0.85 f cd

f
= 0.0964 m < 0.25 m
0.85 f b
As

yd

cd

x = 1.25y = 0.12 m
y

= A f d - = 1232.3 kN m
2

e
e
d-x
0.95 - 0.12
=
e =e
= 0.0035
= 0.024 > e
x
d-x
x
0.12

Mu

yd

por lo tanto, la rotura es dctil.


Este momento deber ser igual al momento de clculo Md, producido por las siguientes cargas: peso
propio, impermeabilizacin, carga de mantenimiento y sobrecarga de tierras. Las dos primeras se
suponen permanentes y las dos ltimas variables. No siendo, en principio, el control de calidad
intenso, se adoptarn los siguientes valores de los coeficientes de mayoracin de acciones:
1.5;

fq

= 1.6, con lo que:

Los autores, 1998; Edicions UPC, 1998.

fg

255

E.L.U. a cortante-friccin

gl
= 1.5
8

Md

+ 1.6 (c + q ) l = M = 1232.3 kN m
8

Puesto que g = 25.25 kN/m y cm = 1 kN/m , se tiene que:

= 1.5

Md

25.25 12.8

+ 1.6 1

12.8
8

+ 1.6 q

12.8
8

= 1232.3 kN m

de donde:
3

q = 12.93 kN/m = 21 kN/m (1 m)(h (m))


Finalmente, la altura de tierras es:
h = 0.615 m

2 Clculo de la armadura pasa nte:


Para el clculo de la armadura pasante se proceder a aplicar la teora del cortante-friccin. La
tensin rasante que solicita la junta en la seccin debe cumplir que:

t
t

md

b f

md

ct ,d

A st

s p

y ,d

(m sen a + cos a ) + m s 0.25 f


cd

cd

es el valor medio de la tensin rasante de clculo de la junta, que puede obtenerse a travs de:

md

Vd

p z

(1.5 g + 1.6 (c + q )) 0.5 12.80


= 450 kN / m = 0.45 MPa
2

1 m 0.9 d

donde g son las cargas permanentes que actan sobre la seccin compuesta. En este caso, dado que
el recrecido se hace apeando la losa, el caso ms desfavorable es considerar g la totalidad de las
cargas permanentes, esto es g = 25.25 kN/m.
z = 0.9d = 0.90.95 = 0.855 m
f ct ,d

0.21

f ck

= 1.19 MPa = 1190 kN / m

1.5

Dado que no se sabe a priori la rugosidad, se supone que sta es baja, adoptndose los siguientes
valores:

b = 0.2 m = 0.6
a = 90 (armadura vertical)
fya,d = 400 MPa (pues la que resulta de clculo es superior: 435 MPa)

cd

g h
c

g h
t

= 25 kN/m 0.25 + 210.615 = 19.165 kN/m

Los autores, 1998; Edicions UPC, 1998.

256

Hormign armado y pretensado. Ejercicios

450
A st
s

0.2 1190 +
=

A st
s

- 249.5
=
400000 0.6

400000
1

450

(0.6 1 + 0 ) + 0.6 19.165

200.5

400000 0.6

Ello requiere disponer barras de

= 0.000835 m

/ ml

= 8.35 cm

/ ml

f16 cada 25 cm en la zona A, de mayor esfuerzo cortante.

Esta zona tiene una extensin tal que el cortante sea menor que Vcd = 200 kN (lo resistido sin

armadura pasante) en base a Vcd = ( fct,d +

Vd = R -px

ms

c.d

)pz = 213 kN

-V

p = 1.5g + 1.6(cm + q) = 1.525.25 + 1.613.93 = 60.16 kN/m

60.16 12.8

385

- 213

60.16

= 385 kN

= 2.86 m

As pues, se dispondr armadura pasante en lA = x + h

4 m desde cada apoyo. Se aumenta un

canto debido a que el agotamiento por cortante es un fenmeno zonal y no seccional.

Los autores, 1998; Edicions UPC, 1998.

257

E.L.U. adherencia y anclaje

Ejercicio II-12 Anclaje de armaduras postesas


Dimensionar la zona de anclaje de un tendn con una fuerza de pretensado de 2000 kN, el cual
corresponde a una viga pretensada con armaduras postesas de seccin rectangular de 40 cm de
ancho (ver figura a). En la misma se emplean placas de anclaje cuadradas de 20 cm de lado. La viga
2

es prefabricada con una resistencia caracterstica del hormign de 40 N/mm y una consistencia
plstica.

Solucin
El anclaje de la armadura activa, tal como indica la EHE (artculo 61), constituye una regin D en
la que la distribucin de deformaciones es no lineal a nivel seccin (figura b). En consecuencia,
para su estudio es de aplicacin el mtodo general de bielas y tirantes, de los artculos 24 y 40 o el
resultado de estudios experimentales.
Hasta la fecha el dimensionamiento de las zonas de anclaje se ha venido haciendo en Espaa a travs
de la normativa de hormign pretensado anterior o bien, con cierta frecuencia, segn formulaciones
dadas por los fabricantes de los sistemas de pretensado, basadas inicialmente en los trabajos
experimentales de Zielinsky y Rowe, los cuales se han ido poniendo al da en funcin del sistema y
la evolucin de los equipos de los mismos.
El tratamiento de la zona de anclaje puede verse como un caso particular de carga concentrada sobre
macizo (artculo 60 de la EHE), siguiendo en este ejemplo dicho planteamiento, por la simplicidad
conceptual que representa. En el mismo se trata de verificar que no se agota el hormign por
compresin bajo la placa de anclaje y de disponer de la armadura necesaria para absorber las
tracciones de los tirantes de traccin posteriores (ver figura b).
Verificacin compresiones
Debe cumplirse que: Nd

Nu

donde:
Nd es la solicitacin (P =2000 kN)
Nu es la respuesta, la cual viene dada, en el caso de confinamiento, como el presente, por
la expresin:

Nu = Ac1 f3cd = 40000 mm 53.33 = 2133.3 kN > Nd


2

Ac1 = 200 x 200 =40000 mm

Ac = 400 x 400 = 160000 mm

Los autores, 1998; Edicions UPC, 1998.

258

Hormign armado y pretensado. Ejercicios

c dg
tendones

a 1= 20

9 cm
20

20

a = 40
Fig. a

Fig. b

f 3 cd

Ac
A c1

f cd =

1600000
40000

f cd = 53.33 MPa

Los autores, 1998; Edicions UPC, 1998.

259

E.L.U. adherencia y anclaje

y, adems verificar que:


Nu

Ac f1cd

con

= 160000 mm 19,04 = 3046 kN > Nd


2

f1cd = 0,85 (1-fck/250) fcd = 0,85 (1- 40/250) 40/1,5 = 19,04 N/mm

Armaduras transversales
Los tirantes Td indicados en la figura se dimensionarn para la traccin de clculo indicada en la
siguiente expresin:
Td = 025 Nd (1-a1/a) = 0,25 2000 (1-20/40) = 250 kN
Para el clculo de la armadura se toma:
Td = As

sS ,

es decir As = Td/

ss

Desde el punto de vista de un estado lmite ltimo, el valor de

ss

debera ser fyd. Ahora bien, la

adopcin de este valor no garantiza el control de la fisuracin en situaciones de servicio. Por ello es
usual limitar el valor de

ss, adoptndose con frecuencia el valor de 200 N/mm2. Tomando este valor
2

se obtiene que la armadura transversal es de 1250 mm . Esta armadura debe disponerse en una
profundidad entre 0,1 a y a que es la zona traccionada. Dicha disposicin suele hacerse uniforme
para evitar problemas de hormigonado en una zona con gran congestin de armadura. En el caso
estudiado, dicha armadura implica 4 cercos que envuelven las trompetas con redondos de 20 mm de
dimetro o bien una armadura helicoidal, de igual dimetro, con un paso de 9 cm.
A esta armadura local hay que aadirle la armadura que se requiera en dicha zona por los efectos
estructurales globales, as como la que se disponga por otro tipo de razones (p.ej.: constructivas).
Esta congestin de armadura aumenta las dificultades de hormigonado, y en el caso que nos ocupa
con una consistencia plstica requerira una compactacin intensa, ya sea slo interna o bien
apoyada por una vibracin externa, dado que se trata de un elemento prefabricado. Asimismo, estas
dificultades pueden condicionar el tamao mximo del rido a emplear.

Los autores, 1998; Edicions UPC, 1998.

261

E.L.U. adherencia y anclaje

Ejercicio II-13 Anclaje por adherencia de armaduras pretesas


Se ha de realizar el dimensionamiento de la armadura de la zona de anclaje de una viga de hormign
pretensado con armadura pretesa, de seccin rectangular, con las siguientes caractersticas:
- b =15 cm
- h = 40 cm
- P0 = 330 kN
- e = -9.5 cm, medidos desde el c.d.g. de la seccin
Las caractersticas de los materiales son:
- Armaduras pasivas de acero B500 S, fyk = 500 MPa
- Hormign HA-25/B/18/IIa
- Armaduras activas a base de cordones Y1860 S7:
n = 3 cordones de pretensado
2

Ap (1 cordn) = 95.4 mm

f =12.5 mm

fpmx = 1860MPa
fpyk = 1580MPa

Se pide:
1. Realizar el dimensionamiento de la zona de anclaje de la viga, para garantizar el cumplimiento
del correspondiente estado lmite ltimo.

Solucin
1 Obtencin de la longitud de t ransferencia de pretensado.
Para la obtencin de la longitud de transferencia se utilizar la propuesta del Cdigo Modelo 1990
del Comit Euro-Internacional del Hormign.
La frmula del CM-90 es la siguiente:

Los autores, 1998; Edicions UPC, 1998.

262

Hormign armado y pretensado. Ejercicios

= a 8 a 9 l bp

l bpt

s pi

f pd

a8 = 1
a 9 = 0.5
a 10 = 0.5
s pi =
A sp

fp
l bp

30000

= 1075MPa

Ap

A sp

f ptd

fp

f bpd

= 218.6mm

h p2 = 1

f bpd
f pd

f ctk

= 1.5MPa

1.5

= h p1 h p 2 f ctd = 1798MPa
= 1617.3MPa

s pi =

Se considera el destesado gradual


Para dimensionamiento del anclaje
Por ser cordones de pretensado
Tensin tras prdidas instantneas

f = 2.43mm

36

h p1 = 1.2

f ctd

Longitud de transmisin

30000

3 0.93

= 1075.2MPa

l bpt = a 8 a 9 a10

s pi
f pd

Longitud de anclaje bsica

Por ser cordones


Por la posicin del cordn en la seccin

donde f ctk

= 0.21 (f

ck

2 3

resistencia de clculo de adherencia

f p,max / 1.15

= 36.33cm

2 Dimensionamiento de la zona de anclaje


Una vez calculada la longitud de transmisin del pretensado se procede a la determinacin del
estado tensional en la viga, producido por la accin del pretensado, correspondiente a una seccin lo
suficientemente alejada del extremo de la pieza (lbpt + h), como para considerar que se cumplen las
hiptesis de resistencia de materiales.
Las caractersticas geomtricas de la seccin bruta son:

A
I

= 600cm 2

1
12

15 40 3 = 80000 cm 4

Los autores, 1998; Edicions UPC, 1998.

263

E.L.U. adherencia y anclaje

@ 300kN
- 30000 30000 -9.5 20
s inf =
+
= -121.25
Pki

600

s sup =

80000

- 30000
600

30000

-9.5 20

80000

= 21.25

kp
cm

kp
cm

= -12.125MPa

= 2.125MPa

Se plantea el siguiente modelo biela-tirante para el dimensionamiento de la zona. Existen infinitos


esquemas estticos que permiten aproximar el comportamiento; el que se elija debe ser un sistema
equilibrado con la longitud mnima de tirantes.
Planteando el modelo biela-tirante, segn aparece en la figura, se tiene:
2.125 MPa

T2

C3

C7

0.40
cm

C5

Eje P

C6

9.5067 kN
7.95 cm
9.5067 kN

C2

T1

13.19 cm
148.32 kN
6.37 cm

C4

T3

5.73 cm

C1

151.68 kN

-12.125 MPa
c
lbpt
Biela comprimida
Tirante

El clculo de las cuatro fuerzas C1, C2, C3 y T se obtienen de la siguiente manera.


La traccin vale T

1
2

s ct b x =

s c,inf
1+
s c,sup

1
2

400

=
1

12.125

2.125 150 59.65 = 9506.7 N , donde:


= 59.65 mm

2.125

sct = 2.125 N/mm

La compresin C3 (la superior ) se hace igual a T y su lnea de paso se calcula en el c.d.g. del
tringulo de compresiones correspondiente, es decir el brazo del par C-T es:
z = 2/3 x 2 = 4/3 x = 79.5 mm
Las compresiones inferior C1 e intermedia C2 se calculan por equilibrio global, teniendo en cuenta
que C3 = T :

Los autores, 1998; Edicions UPC, 1998.

264

Hormign armado y pretensado. Ejercicios

C1 + C2 + C3 T = P
C1 z1 + C2 z2 + T (z3 zt ) = 0
Los brazos zi estn referidos al eje P de la fuerza de pretensado y corresponden a la resultante de los
trapecios de tensiones por encima y por debajo de este eje. Sus valores, como se observa en la
figura, son z1 = -57.3 mm, z2 = 63.7 mm, (z3 - zt ) = 79.5 mm.
De todo ello se deducen C1 = 151.68 kN y C2 = 148.32 kN.
Resolviendo el modelo se tiene T3 = 9.50 kN, T2 = 7.20 kN y T1 = 82.78 kN. Las armaduras a
disponer para absorber T1, T2 y T3 son (tomando fyd = 400 MPa para limitar deformaciones
excesivas ):

T1

T2

T3

82780 N
400 N mm

7200 N
400 N mm

mm

= 18

mm

= 24

mm

9500 N
400 N mm

= 207

bpt

Armadura transversal:
4 cercos de 2f 6

Armadura longitudinal: 2f6

Los autores, 1998; Edicions UPC, 1998.

265

E.L.U. pandeo

Ejercicio II-14 Dimensionamiento de soportes esbeltos aislados: mtodos simplificados


y columna modelo

Una columna de hormign armado de una nave industrial tiene 5 m de altura libre y seccin
cuadrada de 40 cm de lado. La columna se considera empotrada en su base y libre en su extremo
superior, donde recibe las acciones verticales y horizontales procedentes de la cubierta. A efectos de
clculos se considera, adems, arriostrada en el plano perpendicular al del dibujo por el muro de
fachada de la nave.
Las propiedades de proyecto de los materiales son:
- hormign: HA-30/P/12/II
- armaduras: B500 S
Se considera un nivel de control normal.

Se pide:

1. Dimensionar la armadura longitudinal en la seccin de la base necesaria para resistir las


solicitaciones de clculo siguientes, teniendo en cuenta los efectos de segundo orden, de acuerdo con
el mtodo simplificado propuesto por la Instruccin EHE:
a) N = 625kN, M = 0
b) N = 625kN, M = 125 kNm
En ambos casos el esfuerzo axil cuasi permanente no supera el 70% del total.
2. Considerando la armadura simtrica obtenida en el apartado anterior, obtener el mximo
momento exterior de primer orden que puede introducirse, segn el mtodo de la Columna Modelo,
d

Los autores, 1998; Edicions UPC, 1998.

266

Hormign armado y pretensado. Ejercicios

suponiendo que la armadura es constante en toda la barra y adoptando un diagrama momento - axil curvatura de la seccin de la base trilineal.
3. De acuerdo con el mtodo de la Columna Modelo, evaluar los momentos de segundo orden que
se produciran al aplicar el momento exterior de primer orden obtenido en el apartado 2 e identificar
si la rotura de la columna se producira por inestabilidad o por agotamiento de los materiales
Solucin

1. Al considerar la columna empotrada en su base y libre en su extremo superior, se adopta como


longitud de pandeo el doble de la longitud real, esto es, l = 10 m.
Teniendo en cuenta este valor de la longitud de pandeo y el radio de giro de la seccin
i = AI = 0.115 m (A = 0.16 m ; I = 0.0021 m ), se obtiene una esbeltez mecnica igual a
l = 86.60. Puesto que es mayor que 35 y menor que 100, se puede aplicar el mtodo
l=
i
simplificado aproximado propuesto por la instruccin EHE para el caso de flexin compuesta recta.
a) N = 625 kN
M =0
Como la estructura es traslacional y dado que la excentricidad de primer orden e =M /N es nula,
se adopta como excentricidad un valor e = e = h/20 = 20 mm.
La excentricidad adicional valdr,
0

02

= [1 + 0.12b] [e y + e]

02

h + 20e l = 147 mm
h + 10e 50 i
2

donde:
b =1

(Armadura simtrica en dos caras)


f = 435 = 2.175 10 e =
E 200000
e = 0.0035 ( Axil cuasipermanente < 70% N )
yd

Por tanto debe dimensionarse el soporte para un esfuerzo axil N = 625 kN y una excentricidad
e=e +e =20+147=167 mm.
Dimensionando con armadura simtrica se tiene:
N < 0.425 U = 0.425 20 400 35 10 =1190 kN
d

-3

Los autores, 1998; Edicions UPC, 1998.

267

E.L.U. pandeo

N e + d - h2 - 0.85 f b y d - y 2 198.12 - 190.0

A f =
=
= 27.0 kN
0.3
d-d
y = 0.85N f b = 91.91 mm
= =
< A = 0.04 Uf = 257 mm
d

cd

'

yc,d

'

cd

'

As

As

62.07 mm

smin

yd

Por lo que se disponen 4f16, uno en cada esquina.

b) N = 625 kN
M = 125 kNm
La excentricidad equivalente es la de primer orden e = e = M /N = 0.2 m= 200 mm., que es
superior a la accidental.
En este caso, la excentricidad adicional ser:
d

= [1 + 0.12b] [e y + e]

h + 20 e l
h + 10 e 50 i
2

02

= 202.6 mm

Por tanto la excentricidad total ser e = e + e = 402.6 mm.


Dimensionando igualmente con armadura simtrica se tiene:
N < 0.425 U , por tanto
y = 0.85N f b = 91.91 mm
) 10 - - 190.0 = 518.0 kN
A f = 625 (402.6 + 150
0.3
A = A = 1190 mm
TOT

cd

'

yd

'

Lo cual se consigue disponiendo 4f20 cada cara.

Los autores, 1998; Edicions UPC, 1998.

268

Hormign armado y pretensado. Ejercicios

2. El mtodo de la Columna Modelo se basa en la obtencin del diagrama momento-curvatura de la


seccin. ste representa el momento interno o el resistido, que deber ser igual al momento
solicitacin, compuesto por el momento de primer orden y el de segundo orden.
El momento de segundo orden vale: M = N10 l c , siendo c la curvatura, y puede representarse
en la misma figura que el diagrama momento-curvatura como una lnea con pendiente N10 l .
Entonces, la diferencia entre esta lnea y el diagrama momento-curvatura es el momento de primer
orden que absorbe la seccin.
2
0

2
0

M
N = cte.

II

M1

Nl 0

M 1,max
A

10
M
C

II

Para un caso como el de la figura, donde el diagrama momento-curvatura es trilineal, el mximo


momento de primer orden que resiste la seccin es el que se obtiene en el punto B, de paso de
seccin fisurada a plastificacin. Este mximo momento de primer orden tiene asociado un
momento de segundo orden.
As pues, los apartados 2 y 3 se resuelven obteniendo las caractersticas del punto B.
Para obtener el punto B, es decir, el momento de plastificacin, tantearemos dos posibilidades:
1) que el hormign plastifique (e = - 0.002) antes de que lo haga el acero de las
armaduras (e = e = f /E = 2.17410 ).
2) que el acero plastifique antes que el hormign.
Utilizaremos el mtodo parbola-rectngulo, ya que la simplicidad geomtrica de la seccin lo
permite.
c

yd

-.3

Los autores, 1998; Edicions UPC, 1998.

269

E.L.U. pandeo

Caso 1) e = - 0.002
c

Planteando las ecuaciones de equilibrio se tiene:


N = C + C - T = 23 0.85f bx + A s - A s
M + N d - h2 = Cz + C (d - d)

2
C = 3 0.85f bx = 0.566f bx
z = d - x4
e
e
e'
d-x
=
=
s = 0.002 E
x
x d - x x - d'
x
- d'
s ' = 0.002 E
x
d

cd

(1)

(2)
(3)
(4)

cd

(5)
(6)

cd

Sustituyendo (5) y (6) en (1) se tiene:


N = 0.566f bx + A 0.002 E x -x d' - A 0.002 E d -x x
A = A = 1256 mm
Para:
f = 20 MPa
E = 200000 MPa
d = 350 mm
N = 625000 N
d = 50 mm
b = 400 mm
La solucin es x = 173 mm.
- 173
= 409.9 MPa . Por tanto, como s < f , la hiptesis
Con ello s = 0.002 2 10 350173
realizada es la correcta y no hace falta comprobar la opcin b).
Para conocer el punto B necesitaremos tambin conocer:
d

cd

cd

Los autores, 1998; Edicions UPC, 1998.

yd

270

Hormign armado y pretensado. Ejercicios

s s ' = 0.002 2 10 5

173 - 50 = 284.3 MPa


173

Entonces el momento ser:


M + N d - h2 = 0.566f bx d - x4 + A s (d - d) =

173
= 10 - 0.566 20 400 173 350 - 4 + 1256 284.3 300 = 347.7 kNm
d

cd

y el momento exterior:
M = 347.7 N d - h2 = 347.7 - 625(0.35 0.2) = 254 kNm
d

La curvatura ser:
.002 = 11.56 10 - mm c = ex = d e- x = 0173
Momento ltimo.
El momento ltimo se calcular suponiendo que el agotamiento se produce en el dominio 3 y
verificando posteriormente que as es. En tal caso:
e = -0.0035
s = 0.85f
e >e
s =f
s =f
N = yf bx + A f - A f
M + N d - h2 = yf bx(d - lx)+ A f (d - d)
c

cd

cd

yd

yd

yd

yd

cd

yd

Para e = 0.0035, y= 0.688 y l = 0.416


x = N + AY ff -bA 'f = 0.688625000
= 113.5 mm
20 400
M + N d - h2 = 10 - [625000 (350 - 0.416 113.5) + 1256 435 300] = 353.2 kN m

M = 353.2 625(0.35 0.2) = 259.45 kNm


La curvatura ltima ser:
.0035 = 30.89 10 - mm c = ex = 0113
.3
c

yd

yd

cd

Los autores, 1998; Edicions UPC, 1998.

271

E.L.U. pandeo

Con estos valores, el diagrama M-c ser como indica la figura.


M(kN.m)

259.45

254.0

=M

-M

II

M fis = 63.2

M II
0.35

Nlo
10

11.56

1
r

30.89

10

-3

-1

I f + N = 0.002133 2020 + 625 = 63.20 kN m


v' A 0.20
0.16
2.02 = 0.35 10 - mm c = E f v' = 28573
200
M

fis

ct

ct

fis

Segn el mtodo de la columna modelo, el mximo momento exterior que puede introducirse ser:
M = M - N l10 1r = 254 - 625 1010 11.56 10 - = 254 - 72.25 = 181.75 kN m

2

I
max

3. De acuerdo con el apartado anterior, el momento de 1 orden de valor 181.75 kNm dara lugar a
un momento de 2 orden de valor 72.25 kNm (lo que representa un 40% aproximadamente, que es
muy alto). Dado que el mximo se produce para un punto de curvatura inferior a la ltima se
producira inestabilidad de la columna, y no agotamiento de los materiales.
er

Los autores, 1998; Edicions UPC, 1998.

273

E.L.U. pandeo

Ejercicio II-15 Comprobacin de soportes esbeltos en prticos

La estructura de un edificio exento consiste en prticos de hormign armado arriostrados entre s,


separados 5.0 m y unidos a pantallas que los rigidizan lateralmente. Aunque el edificio es
traslacional, su desplazamiento en cabeza frente a las acciones laterales caractersticas es menor que
1/750 de su altura. Cada prtico es de 4 vanos de 6 m de luz, con 4 m de altura en cada planta,
excepto en planta baja donde es de 5 m, siendo 12 el nmero total de plantas del edificio. Las vigas
de todas las plantas del prtico son rectangulares, de b=30 cm y h= 40 cm. Los pilares son todos
cuadrados, aumentando su lado de arriba a abajo. El forjado es unidireccional a base de semivigueta
armada, bovedilla cermica y capa de compresin.
El hormign tanto de vigas como de soportes es HA-25/P/20/II. Las armaduras consisten en barras
corrugadas de acero B 500 S.
Se pide:

Dimensionar frente a pandeo los siguientes soportes representativos, cuyas caractersticas


geomtricas y esfuerzos de clculo se indican a continuacin, disponiendo armadura simtrica en
dos caras opuestas.
a) Soporte interior en planta baja de seccin 50x50 cm, y 5 m de altura, sometido a los siguientes
esfuerzos: N = 1800 kN, M = 250 kNm, M = - 300 kNm.
b) Soporte de fachada planta intermedia, de seccin 40x40 cm, y 4 m de altura, sometido a los
esfuerzos: N = 1200 kN, M = 200 kNm, M = - 250 kNm.
c) Soporte de fachada planta superior, de seccin 30x30 cm y 4 m de altura, sometido a los
siguientes esfuerzos: N = 400 kN, M = 150 kNm, M = - 200 kNm.
En ningn caso el esfuerzo axil cuasi permanente supera el 70% del total.
d

dsup

dinf

dsup

dinf

dsup

dinf

Nota:

Solucin

Aunque la estructura es traslacional, al tener menos de 15 plantas y satisfacerse que la flecha bajo
cargas horizontales caractersticas es menor que h/750, el clculo global de esfuerzos se puede
realizar segn la teora de primer orden y la comprobacin al pandeo podr realizarse a cada soporte
aislado.
Por otra parte, para aplicar el mtodo simplificado deber verificarse que la esbeltez mecnica
l = l / i sea menor que 100; lo cual, como veremos ms adelante, se cumple en todos los casos.
o

Los autores, 1998; Edicions UPC, 1998.

274

Hormign armado y pretensado. Ejercicios

Para la aplicacin de este mtodo simplificado y el dimensionamiento de los soportes se consideran


diversos parmetros comunes:
Caractersticas de los materiales:
- hormign: f = 16.67 MPa
- acero: f = 434.78 MPa
E = 200000 MPa
f = 2.17 10
e =
E
cd

yd

-3

yd

Caractersticas de los elementos del prtico:


pilar de 50x50 cm : I = 0.0052 m (momento de inercia)
i = 0.144 m (radio de giro)
l = 5 m (longitud)
pilar de 40x40 cm : I = 0.0021 m (momento de inercia)
i = 0.115 m (radio de giro)
l = 4 m (longitud)
pilar de 30x30 cm : I = 0.000675m (momento de inercia)
i = 0.0866 m (radio de giro)
l = 4 m (longitud)
vigas de 30x40 cm : I = 0.0016 m (momento de inercia)
l = 6 m (longitud)
a) La longitud de pandeo l = al se obtiene a partir de la formulacin para prticos
intraslacionales:
2

p50

50

p40

40

p30

30

a=

7.5 + 4 (Y + Y ) + 1.6 Y
7.5 + (Y + Y )
A

= 1.36

En este caso:
Y = 0 (extremo empotrado)
I +I
l l = 2.95
Y =
2 Il
a = 1.36
l = 1.365000 = 6800 mm
A

p 50

p 40

50

40

Los autores, 1998; Edicions UPC, 1998.

275

E.L.U. pandeo

6800 = 47.22 se puede aplicar el mtodo simplificado.


0.144
Como valor de la excentricidad total e se adopta el mayor valor de los siguientes:
e = 0.6e + 0.4e = 0.045 m
30 = 0.167 m
e = MN = 180
-25
e = MN = 180
= -0.139 m
0.4 e = 0.067 m
h/20 = 2.5 cm
2 cm
Es decir, se adopta el valor e = 67 mm
La excentricidad adicional ser:
20e l =
e = [1 + 0.12b] [e + e] hh ++ 10
e 50 i
500 + 20 67 6800 = 64.14 mm
= [1 + 0.12 ] [0.00217 + 0.0035]
500 + 10 67 50 144
e = e + e = 67+64 = 131 mm
El dimensionamiento a pandeo de la seccin del soporte se lleva a cabo con el siguiente par de
esfuerzos (N , M = N e ) = (1800 kN, 235.8 kNm), que adoptan los siguientes valores
adimensionales: (n, m) = (0.432, 0.112).
Entrando en el correspondiente diagrama de interaccin (para armadura dispuesta simtricamente en
las caras exteriores de la seccin) se obtiene que es necesario disponer una armadura mnima (w
= 0.02).
No obstante, la excentricidad e = 167 mm es mayor que la excentricidad total equivalente e =
131 mm. Por lo tanto, ser determinante el dimensionamiento a flexocompresin. En este caso el
par de esfuerzos adimensionales que se han de considerar es (n, m) = (0.432, 0.144), lo cual
implica que la cuanta de armadura necesaria es w=0.11, que se corresponde con un rea total de
1054 mm . Esta cuanta se consigue disponiendo 3f16 en cada cara.
Esta armadura es superior a la mnima, que se corresponde con un 0.28% sobre la seccin de
hormign:
A = 0.0028A = 0.0028500 = 700 mm
l=

TOT

TOT

TOT

s,min

Los autores, 1998; Edicions UPC, 1998.

276

Hormign armado y pretensado. Ejercicios

b) Para el caso de soportes de fachada en una planta intermedia la longitud de pandeo se obtiene a
partir de los siguientes factores:
2 Il
Y =Y =
I = 3.94
l
a = 2.04
l = 2.04 4000 = 8150 mm
p 40

40

Con este valor de la longitud de pandeo la esbeltez mecnica es l = 70.9 < 100, por lo que se
puede aplicar el mtodo simplificado.
La excentricidad equivalente e ser:
e = 0.6e + 0.4e = 0.058 m
25 = 0.208 m
e = MN = 120
e = MN = -12020 = -0.167 m
e

Tal como suceda en el caso anterior, el valor de 0.4e = 0.083 m es superior al obtenido. As, se
considera un valor de la excentricidad equivalente igual a 83 mm.
La excentricidad adicional ser:
+ 20 83 8150
e = [1 + 0.12] [0.0035 + 0.00217] 400
400 + 10 83 50 115 = 123 mm
La excentricidad total valdr:
e = e + e = 83+123 = 206 mm.
El par de esfuerzos dimensionales con el que ha de dimensionarse a pandeo el soporte es: (N , M =
N e ) = (1200 kN, 247 kNm), que se corresponde con los siguientes valores adimensionales:
(n, m) = (0.45, 0.23).
La cuanta de armadura necesaria que se obtiene a partir del diagrama de interaccin
correspondiente es w = 0.32; esto es, una armadura total de valor 1962 mm .
2

TOT

TOT

Los autores, 1998; Edicions UPC, 1998.

277

E.L.U. pandeo

La excentricidad en un extremo e =208 mm es mayor que la excentricidad total e=200 mm.


Entonces, la armadura que se ha de disponer vendr dada por el dimensionamiento a
flexocompresin resultante de considerar dicha excentricidad e =208 mm. Los esfuerzos
adimensionales son, para este caso, (n, m) = (0.45, 0.234). La cuanta necesaria de armadura es
entonces w= 0.35, o sea, un rea total de 2147 mm , que se puede conseguir disponiendo 6f16 en
cada cara de la seccin.
La armadura mnima es A =0.0028 400 =448 mm , inferior a la necesaria por clculo.
c) En el caso de un soporte de fachada de la planta superior los coeficientes que determinan la
longitud de pandeo son:
I
l = 1.97
Y =
I
l
2 Il
Y =
I = 3.94
l
a = 1.80
l = 1.80 4000 = 7209 mm
l = 83.25 < 100 se puede aplicar el mtodo simplificado
La excentricidad equivalente se obtiene as:
e = 0.6e + 0.4e = 0.15 m 0.4 e
e = MN = 200
400 = 0.5 m
150 = -0.375 m
e = MN = -400
2

s,min

p 40

40

p 40

40

>
/

El valor de 0.4e = 0.2 es mayor que el obtenido para e . As pues, se considera un valor de 200
mm para la excentricidad equivalente.
La excentricidad adicional valdr:
+ 20 200 7209
e = [1 + 0.12 1] [00035 + 0.00217] 300
300 + 10 200 50 86.6 = 142mm
La excentricidad total sera e =e + e = 342 mm.
2

TOT

Los autores, 1998; Edicions UPC, 1998.

278

Hormign armado y pretensado. Ejercicios

400000 = 0.266
16.67 300 300
136800000 = 0.304
m=
16.67 300 300
Los valores de los esfuerzos de clculo que se consideran en el dimensionamiento a pandeo son:
(N , M = N e ) = (400 kN, 136.8 kNm). Los esfuerzos adimensionales asociados a ellos son:
(n, u) = 0.66, m =0.30.
La seccin no rompe frente a estos esfuerzos si se coloca una cuanta de armadura superior al valor
w =0.52; o lo que es lo mismo, se evita la rotura a pandeo de la seccin disponiendo una armadura
con un rea total superior a 1793 mm .
Se ha de comprobar tambin que la seccin extrema no rompe a flexocompresin. Dado que e =500
mm es superior a e =239.3 mm, la rotura por pandeo no es determinante en este caso, y la seccin
se ha de dimensionar teniendo en cuenta la excentricidad e . Los esfuerzos adimensionales resultante
en ese caso son: (n, m) = (0.26, 0.40). Disponiendo una cuanta de armadura igual wTOT=0.76
(rea total de 2621 mm o lo que es igual 5f20 por cara) se evita esta rotura. Esta armadura es
superior a la armadura mnima que se ha de colocar en cualquier caso (448 mm , correspondiente a
un 0.28% de la seccin de hormign).
n=

TOT

3 16

6 16

2 8
500

5 20

2 8

2 8
400

cercos > 6 mm
S < 240 mm
t

500

3 16

6 16

400

400
cercos > 6 mm
S < 240 mm
t

Pilar base

Pilar intermedio

Los autores, 1998; Edicions UPC, 1998.

Pilar superior

5 20

279

E.L.U. servicio

Ejercicio II-16 Fisuracin y deformabilidad en vigas de hormign armado

Sea una viga de hormign armado simplemente apoyada de 10 metros de luz, con seccin
transversal rectangular de 30 cm de ancho por 70 de canto.
La disposicin de armaduras en la seccin central es la que se indica en la figura.

Se considera las siguientes cargas que actan en la secuencia que se indica


- peso propio a los 28 das
- carga permanente de 2 kN/m a los 90 das
- sobrecarga de uso, constituida por una carga uniformemente distribuida de 4 kN/m y una
carga puntual mvil de 40 kN en cualquier instante a partir de los 90 das.
Se adoptarn las propiedades del hormign HA-25/P/12/IIb establecidas por la Instruccin EHE,
tanto en el comportamiento instantneo como diferido. La armadura consiste en barras corrugadas
de acero B 500 S.
Se pide:

1. Comprobar el estado lmite de fisuracin en la seccin central y, en caso de que ste no se


satisfaga proponer soluciones.
2. Verificar la necesidad de comprobar el estado lmite de deformacin segn los criterios
establecidos por la Instruccin EHE.
3. Calcular la flecha instantnea en el centro de la viga debida a cada una de las cargas actuantes.
4. Calcular la flecha diferida debida a cargas permanentes, la flecha total y la activa.

Los autores, 1998; Edicions UPC, 1998.

280

Hormign armado y pretensado. Ejercicios

Se utilizarn los coeficientes de fluencia y retraccin propuestos en la instruccin EHE,


considerando una humedad relativa del 70 %. Para las combinaciones de acciones, en la
comprobacin de los distintos E.L.S., se utilizarn los siguientes coeficientes g y y : g = 1.0, g
= 1.0, y = 0.7, y = 0.5, y = 0.3.
Nota:

0,1

1,1

G,j

Q,1

2,1

Solucin

En primer lugar se calculan los momentos en la seccin centro de vano debidos a las diferentes
cargas:
- peso propio: pp = 250.30.7 = 5.25 kN/m
M = pp8 l = 65.625 kN m
- carga permanente: cp = 2 kN/m
M = cp8 l = 25 kN m
- sobrecarga de uso uniforme: sc = 4 kN/m
M = sc8 l = 50 kN m
- sobrecarga puntual mvil: Q = 40 kN
M = Q4 l = 100 kN m
Seguidamente se combinan adecuadamente estos valores para determinar cul es la situacin psima
que habr que considerar en la comprobacin de los diferentes estados lmite de servicio.
Las diferentes situaciones que se consideran son:
- poco probable: Sg G +g Q +y g Q M = 240.625 kNm
- frecuente: Sg G +y g Q +y g Q M = 165.625 kNm
- casi permanente: Sg G +y g Q +y g Q M = 135.625 kNm.
Dado que la nica accin variable es la sobrecarga de uso, sta es la determinante.
2

pp

cp

sc

G,j

G,j

k,j

k,j

Q,1

1,1

G,j

k,j

Q,1

k,1

k,1

2,1

0,2

Q,2

2,2

Q,1

Q,2

k,1

pp

k,2

fr

k,2

2,2

Q,2

k,2

qp

1. Fisuracin por traccin


Se ha de verificar que bajo la combinacin de acciones casi permanentes se verifique que la abertura
caracterstica de fisura (w ) es menor que un valor lmite, que en este caso (tipo de exposicin IIb)
es 0.3 mm.
w = bs e
b = 1.7, para fisuracin producida por acciones directas.
s = 2c + 0.2s + 0.4k f AA = 95.8 mm (separacin media de fisuras)
k

sm

c,eficaz
s

Los autores, 1998; Edicions UPC, 1998.

281

E.L.U. servicio

c = 30 mm (recubrimiento de las armaduras de traccin)


s = b/n = 300/5 = 60 mm < 15f = 375 mm (distancia entre barras)
k = 0.125 (por tratarse de flexin simple)
f = 25 mm (dimetro de la barra traccionada)
A = (187.5+92.5)300 = 84000 mm
A = 4415.6 mm (9f25)
1

c,eficaz

sm

s
1 - k

sr

= 2.1710

-4

(alargamiento medio de las armaduras)

d-x
= 57.79 MPa
0.5 b x d - x3 + A n (x - d') (d - d')

(s = tensin de servicio de la armadura pasiva suponiendo seccin fisurada)


s = nM
s

'

x = n (r + r ) + 2 n r + r d' - n (r + r ) = 0.41
d
d

x = 260 mm
M = M = 135.625 kNm
d = 635 mm
d = 42.5 mm
r = 2.3 10
r = 5.2 10
E = 200000 MPa
E = 8500f = 27264 n = 7.3
k = 1 (por ser carga no repetida)
s
M = 0.462
=
s
M
M = - f v' I = 62.72 kN m (momento de fisuracin)
2

'

'

'

qp

-2

-3

1/3

cm

sr

fis

ct ,m

fis

Los autores, 1998; Edicions UPC, 1998.

282

Hormign armado y pretensado. Ejercicios

f = 0.30f = 2.56 MPa (resistencia media a traccin)


e es mayor que 0.4s /E = 1.1110 , por lo cual se adopta el valor que se obtiene en el
clculo anterior.
As pues, se verifica el estado lmite de fisuracin por traccin:
w = w = bs e = 1.795.82.1710 = 0.035 mm < w = 0.3
En cuanto a la
, debe comprobarse que bajo la combinacin de acciones
ms desfavorable la tensin mxima de compresin en el hormign no supera el valor 0.60f .
Dicha tensin la calcularemos en la situacin poco probable teniendo en cuenta que la seccin
fisura. Su valor es:
M
s =
= 9.65 N / mm
x

0.5 b x d - 3 + n A (x - d ) (d - d )
2/3

ct,m

ck

sm

-4

-4

sm

max

fisuracin por compresin

ck,j

'

'

Se verifica que s <0.6f =18 N/mm , donde se ha obtenido f =1.2f =30 N/mm , de
acuerdo con la tabla 30.4.b de la EHE, para hormign de endurecimiento normal.
Por tanto queda satisfecho el estado lmite de fisuracin por compresin.
c

ck,90

ck,90

ck,28

2. Dado que se trata de una viga simplemente apoyada y teniendo en cuenta que la cuanta de
armadura es r = 2.310 , la esbeltez bsica que define la norma es L/d = 14, que es inferior a la
que existe realmente L/d = 10000/635 = 15.7. Por lo tanto, es necesario verificar el estado lmite
de deformacin.
-2

3. La
debida a cada una de las cargas actuantes se obtiene considerando una
interpolacin cbica de la inercia fisurada y sin fisurar, as como el mdulo de deformacin
longitudinal en la edad de actuacin de la carga.
Dado que la seccin puede estar fisurada o no, se calcula la flecha debida a la totalidad de las cargas
actuantes, obtenindose la flecha en cuestin como diferencia entre esta y la provocada por las
cargas que ya actuaban con anterioridad.
La interpolacin que se considera para la inercia es la siguiente:
flecha instantnea

M
=
M

I + 1 -
M

fN

>/ I

El mdulo de deformacin longitudinal del hormign a diferentes edades es:


E = 8500f = 27264 MPa n = 7.3
E = b E = 1.07 27264 = 29173 MPa n = 6.9
1/3
cm

c,28
c,90

90

c,28

Los autores, 1998; Edicions UPC, 1998.

283

E.L.U. servicio

Flecha instantnea debida al peso propio


Primero se verifica si la seccin est fisurada o no. El momento de fisuracin vale M = f W ,
donde f es la resistencia a flexotraccin y W es el mdulo resistente respecto de la fibra inferior.
f = 0.37f = 0.3725 = 3.16 Mpa
W = 2h I = b 6h = 2.45 10 mm
M = 2.4510 mm 3.16 N/mm = 77.4210 Nmm = 77.42 kNm
Como M =M = 65.625 kNm < M , no fisura la pieza, por lo que la inercia a utilizar en el
clculo de la flecha bajo el peso propio, es la inercia elstica (en principio la homogeneizada).
fis

cf

cf

cf

ckj

2/3

2/3

fis

pp

fis

I = I + (n-1)A d - h2 = 0.312 0.7 + 6.33 44.17 10

I = 0.010835 m = 10.83510 mm
5 pp l
d =
384 E I = 2.31 mm
2

-4

(0.635 - 0.35 )

pp
28

Flecha instantnea debida a la carga permanente

El momento actuante es M = M + M = 65.625 +25 = 90.625 kNm > M , por lo que la


pieza fisura en la seccin central, siendo M /M = 0.855.
La inercia fisurada de la seccin central es:
I = kE = n A (d - x ) d - x3 + n A '(x - d') x3 - d' = 6.392 10 mm

pp

cm

fis

fis

II

donde x se ha calculado como en el apartado 1, para j=90 das.


La inercia que se ha de adoptar en el clculo de flechas, teniendo en cuenta la contribucin del
hormign traccionado entre fisuras, ser (frmula de Branson):
I

M
=
M

I + 1 -
M

fis

fis

I = 0.855 10.835 10 + (1 - 0.855 ) 6.392 10

9.16910 mm
que es inferior a la inercia no fisurada, I = 10.38510 mm .
5 (pp + cm ) l = 3.78 mm
d =
384 E I
9

pp

ins

c,28

cm
ins

=d

pp + cm
ins

-d

pp

= 3.78 - 2.31 = 1.47

mm

Los autores, 1998; Edicions UPC, 1998.

I =
e

284

Hormign armado y pretensado. Ejercicios

Flecha instantnea debida a la sobrecarga de uso

Bajo la totalidad de la carga el momento de servicio es M = 225.625 kNm > M , siendo M /M


= 0.344.
La inercia fisurada de la seccin, al ser de hormign armado y estar sometida a flexin simple, no
depende del momento solicitante, por lo que I = 6.39210 mm .
La inercia que se considera en el clculo de flechas es:
I = 0.344 10.83510 + (1 - 0.344 )6.39210 = 6.57310 mm
ser:
5 (pp + cm + sc ) l + Q l = 8.17 + 4.65 = 12.82 mm
d
=
384 E I
48 E I
a

fis

fis

La flecha instantnea bajo cargas totales


4

pp + cm + sc

ins

con lo que la flecha debida a la sobrecarga de uso ser:


d scins = 12.82 - 3.78 = 9.04 mm

que representa una fraccin 1/1100 de la luz.


4. De acuerdo con la instruccin EHE, las
se calculan multiplicando las
instantneas debidas cargas permanentes por un factor l de valor:
x( t ) - x( j)
x
l=
1 + 50 r = 1 + 50 r
donde:
t y j son los instantes de medida y carga, respectivamente
r es la cuanta geomtrica de compresin
x es una funcin dependiente del tiempo dado en el apartado 50.2.2.3 de la EHE.
Para el clculo de la flecha diferida se dividir el tiempo en una serie de intervalos coincidentes con
la aplicacin de las diversas cargas.
Cuando la carga se aplica por fracciones P , P , ... , P , se puede adoptar como valor de x el dado
por:
x P + x P +K+ x P
x=
P + P +K+ P
flechas diferidas

'

'

En el caso que nos ocupa, de 28 a 90 das existe solo el peso propio, por tanto x(90) = 1.0 y
x(28) = 0.7, quedando:

Los autores, 1998; Edicions UPC, 1998.

285

E.L.U. servicio

l =
1

Dd

pp
90

1.0 - 0.7 = 0.3 = 0.238


1 + 50 0.0056 1.26
= d l = 3.78 0.238 = 0.90 mm
pp

ins

y la flecha existente a los 90 das antes de aplicar las cargas permanentes ser:
d

pp
90

=d

pp
ins

(1 + l ) = 4.68 mm
1

La flecha a largo plazo debida al peso propio se obtendr de igual forma pero adoptando para t
un valor x =2.0.
2.0 - 0.7 = 1.07
l =
1.26
Dd = d l = 3.78 1.07 = 4.04 mm
Bajo la accin de la carga permanente de 2 kN/ml, aplicada a los 90 das, la flecha diferida valdr,
teniendo en cuenta que x() = 2.0 y x(90) = 1.0.
2.0 - 1.0 = 0.794
l =
1.26
Dd = d l = 1.47 0.794 = 1.17 mm
2

pp

pp

ins

cp

cp

ins

Por tanto, la flecha total a largo plazo valdr:


d

= Dd + Dd + d
pp

TOTAL

cp

pp + cp + sc
ins

= 4.04 + 1.17 + 12.82 = 18.03 mm

La flecha activa ser aquella que puede afectar a los elementos no estructurales, tales como tabiques
o solados. En nuestro caso es la flecha total menos la que habra antes de colocar la carga muerta,
es decir:
d
=d
- d = 18.03 - 4.68 = 13.35 mm
activa

TOTAL

90

que representa una fraccin l/750, lo cual es ms que aceptable.

Los autores, 1998; Edicions UPC, 1998.

287

E.L.U. servicio

Ejercicio II-17 Fisuracin de una viga de hormign pretensado

Para cubrir el cauce de un ro de 20 m en una zona urbana se proyecta un puente losa de hormign
pretensado con armaduras postesas, de 20 m de luz, 10 m de anchura, 0.80 m de canto y seccin
maciza, tal como indica la figura adjunta.

Sobre el puente actan las siguientes cargas:


- peso propio (peso especfico = 25 kN/m )
- cargas muertas (pavimento, aceras, barandillas, instalaciones) = 2.5 kN/m
- sobrecarga de trfico: 4.0 kN/m ms una carga puntual mvil de 600 kN
Las caractersticas de los materiales son las siguientes:
- hormign: HP-40/P/20/II
- armaduras pasivas: Barras corrugadas de acero B 500 S
- armaduras activas: Cordones de 7 alambres Y 1860 S7 (f =1860 MPa, f =1700 MPa)
Se supone un nivel de control intenso.
El trazado de los tendones de pretensado es parablico, con excentricidad e=0.10 m respecto al
centro de gravedad en anclajes y excentricidad e=- 0.25 m en centro luz. Suponiendo un 10 % de
prdidas instantneas y un 20% de prdidas diferidas, y adoptando una seccin retangular de b = 10
m y h = 0.8 m, y adoptando valores de y = 1 para las hiptesis de combinacin de cargas.
3

max

pyk

Se pide:

1. Dimensionar las armaduras activas y pasivas longitudinales necesarias para resistir las cargas
actuantes, verificando frente a solicitaciones normales tanto las condiciones de servicio como
las de rotura de la seccin central, en los siguientes supuestos:
a) no se permite superar el estado lmite de descompresin bajo ninguna hiptesis de carga.
b) no se permite superar el estado lmite de aparicin de fisuras bajo ninguna hiptesis de
carga.
c) el ancho de fisura debe ser inferior a 0.1 mm.

Los autores, 1998; Edicions UPC, 1998.

288

Hormign armado y pretensado. Ejercicios

Solucin

En primer lugar se obtienen las caractersticas de la seccin:


A=8m
I = 0.427 m
v = - v = 0.4 m
A continuacin se indican los momentos flectores mximos en la seccin crtica (centro de vano),
debidos a las diferentes cargas:
- peso propio: pp = 258 = 200 kN/m
M = pp8 l = 10000 kN m
- carga muerta: cm = 2.510 = 25 kN/m
M = cm8 l = 1250 kN m
- sobrecarga de trfico: sc = 410 = 40 kN/m
M = sc 8 l = 2000 kN m
- vehculo pesado: P = 600 kN
M = P4 l = 3000 kN m
De acuerdo con lo especificado en el enunciado, en la combinacin de acciones se aplica un
coeficiente de simultaneidad y = 1, con lo que se obtienen los siguientes momentos flectores de
clculo:
- estado lmite ltimo:
M = 1.35(10000+1250) + 1.5(2000+3000) = 22687.5 kNm
- estado lmite de servicio:
M = 1(10000+1250+2000+3000) = 16250 kNm
2

pp

cm

sc

a) En primer lugar se procede al dimensionamiento del pretensado de forma que se verifique el


estado lmite de descompresin para cualquier hiptesis de carga.
Se impone que no se produzcan tracciones en ninguna fibra y en ningn instante.
En la fibra superior la situacin psima se produce con la menor fuerza de pretensado (despus de
transferir) y actuando nicamente el peso propio:

Los autores, 1998; Edicions UPC, 1998.

289

E.L.U. servicio

M = g M = 110000 = 10000 kNm


P - P e v - M v 0
s =A I
I
d

pp

ki

ki

sup

Despejando P se obtiene que la fuerza de pretensado en la seccin central debe ser inferior a 85791
kN, lo que supone una fuerza de tesado en anclajes, habida cuenta del 10% de prdidas
instantneas, de 95323 kN.
A largo plazo, la fibra ms traccionada es la inferior, al actuar la totalidad de las cargas junto al
pretensado final.
M = 16250 kNm
P - P e v'- M v' 0
s =A I
I
ki

inf

De esta condicin se obtiene que la fuerza de pretensado a tiempo infinito ha de ser superior a
42380 kN, o lo que es lo mismo, que el pretensado inicial ha de ser superior a 60543 kN.
Estas dos limitaciones llevan a escoger una fuerza de pretensado de valor:
- inicial en anclajes: P = 60543 kN
- tras prdidas instantneas: P = 0.9P = 54488 kN
- a largo plazo: P = 0.7P = 42380 kN
Teniendo en cuenta que la instruccin EHE limita la tensin en el acero a un valor s = 0.75f =
0.751860 = 1395 MPa, el rea de las armaduras activas ha de ser superior a A = P /s =
43400 mm . Este rea se puede conseguir disponiendo 16T20f0.6, con un rea total A = 16
2800 = 44800 mm .
Habiendo dimensionado el pretensado de forma que se satisfagan las condiciones de fisuracin,
ahora queda comprobar que la seccin no agota debido a las solicitaciones normales.
0

ki

p0

pu

p,nec

p0

M = 0.85 f b y d - y2

P = 0.85f by - DT
u

cd

cd

Los autores, 1998; Edicions UPC, 1998.

(1)
(2)

290

Hormign armado y pretensado. Ejercicios

Se hace la hiptesis de considerar que la armadura activa ha plastificado:


P + DT = A f = 44800 1700
1.15 = 66226087 N = 66226 kN
Entonces, de la ecuacin (2) se obtiene que la profundidad del bloque de compresiones en rotura es:
44800 1700
A
f
1.15 = 292.2 mm
y = 0.85 f b =
40
0.85 1.5 10000
que se corresponde con una profundidad de la fibra neutra de valor x=1.25y=365 mm.
Sustituyendo este valor de y en la ecuacin (1), se obtiene un momento ltimo:
M = 33371 kNm
que es superior al momento de clculo: M = 21562.5 kNm.
Queda comprobar la hiptesis de plastificacin de la armadura activa que se ha realizado, la cual
ser cierta si se satisface la siguiente expresin:
e < e + De
donde:
f = 1478.26 = 7.39 10
e =
E 200000
P = 45729000 = 5.10 10
e =
E A 200000 44800
P = P 1 + n A A1 + eI = 45729 kN

n = E /E = 6.5
E = 200000 MPa
E = 8500f = 30891 MPa
d - x = 0.0035 650 - 365 = 2.7310
De = 0.0035
x
365
Se verifica la hiptesis:
e = 7.3910 < e + De = 5.1010 +2.6210 = 7.8310
As pues, la seccin crtica verifica las condiciones de fisuracin y no agota frente a solicitaciones
normales. Por lo tanto, no es necesario disponer armadura pasiva por clculo.
n

pyd

pyd

cd

pyd

Pn

-3

pyd

pyd

-3

Pn

1/3

cm

-3

pyd

-3

Pn

-3

-3

Los autores, 1998; Edicions UPC, 1998.

-3

291

E.L.U. servicio

b) En este caso se ha de imponer que las tensiones en el hormign no superen en ninguna fibra su
resistencia a traccin (f = 0.21f = 2.46 MPa = 2456.2 kN/m ).
Las situaciones psimas en las fibras superior e inferior de la seccin central son las mismas que las
que se han indicado en el apartado anterior. Las expresiones a partir de las cuales se obtiene la
fuerza de pretensado necesaria son las siguientes:
P - P e v - M v 2456.2 kN
s =A I
I
m
M = g M = 110000 = 10000 kNm
P - P e v'- M v' 2456.2 kN
s =I
A I
m
M = 16250 kNm
2/3

ct

ki

ck

ki

sup

pp

inf

Estas condiciones conducen a que la fuerza de pretensado en anclajes ha de estar comprendida entre
los siguientes lmites:
50774 kN P 120356 kN.
Se adopta el lmite inferior como fuerza de pretensado:
- inicial en anclajes: P = 50774 kN
- tras las prdidas instantneas en seccin centro de luz: P =0.9P = 45697 kN
- a largo plazo en la seccin de centro de luz: P = 0.7P = 35542 kN
El rea de armadura activa necesaria es A = P /s =36397 mm , que se consigue disponiendo
13T20f0.6 (A = 132800 = 36400 mm ).
Anlogamente a lo que se ha hecho en el apartado anterior para la verificacin de la seccin frente a
solicitaciones normales, se obtienen los siguientes resultados:
36400 1700
f
A
1.15 = 237.4 mm x=1.25y = 296.7 mm.
y = 0.85 f b =
40
0.85 15 10000
M = 28588 kNm
que tambin es superior al momento de clculo: M = 22687.5 kNm. As pues, no es necesario
disponer armadura pasiva por clculo.
Por lo que se refiere a la verificacin de la hiptesis de plastificacin de la armadura activa, los
valores que se obtienen son:
0

ki

p,nec

p0

pyd

cd

Los autores, 1998; Edicions UPC, 1998.

292

Hormign armado y pretensado. Ejercicios

= 7.3910
= 6.5610
P = 45402 kN
De = 4.4810
Se verifica la hiptesis e =7.3910 < e +De =(6.56+4.48)10 =11.0410 .
e
e

pyd

-3

-3

pn
n

-3

-3

pyd

Pn

-3

-3

c) En el primer apartado se ha dimensionado el pretensado de forma que no se descomprima la


seccin en ninguna situacin.
En el apartado b) se obtiene una fuerza de pretensado menor, pero sin que la seccin llegue a
fisurar. En este caso el grado de pretensado, entendido como la relacin entre la fuerza adoptada y
la que corresponde a la satisfaccin estricta del estado lmite de descompresin, resulta ser k =
0.839.
En este ltimo apartado se busca reducir an ms el pretensado, pero controlando el ancho de
fisura. En este caso el procedimiento para obtener las armaduras que se disponen es el que sigue: en
primer lugar se escoge un grado de pretensado, para despus dimensionar la cuanta de armadura
pasiva de forma que nos acerquemos al ancho de fisura lmite que impone la condicin del
enunciado.
Se elige un grado de pretensado k=2/3=0.667, por lo que la fuerza de pretensado que se considera
en este apartado es:
- inicial en anclajes: P = 0.667P = 0.66760543 = 40382 kN
- despus de transferir: P = 0.9P = 36344 kN
- a largo plazo: P = 0.7P = 28267 kN
Se disponen 11T19f0.6, con un rea total A = 29260 mm , superior a la de la armadura
necesaria si se tiene en cuenta la limitacin de tensin en las armaduras activas: A = 28978
mm .
Para la obtencin de la apertura de fisura es necesario determinar la tensin en las armaduras
pasivas, considerando el pretensado como una accin exterior. Esta tensin se obtiene de plantear el
equilibrio y la compatibilidad de deformaciones en la seccin.
P = 0.5s xb - A Ds - A s
M = 0.5 s x b d - x3 + A s (d - d )

ki

p,nec

De
d -x =
p

d -x
s

Los autores, 1998; Edicions UPC, 1998.

293

E.L.U. servicio

De la compatibilidad de deformaciones en la seccin se puede obtener las tensiones en las armaduras


activas y pasivas a partir de las que hay en el hormign:
d -x
Ds = n s
x
d
-x
s = n s
x
p

y combinando estas expresiones en las ecuaciones del equilibrio, se obtiene que:


P = 0.5 b x - n A (d - x ) - n A (d - x )
M 0.5 b x d - x + n A (d - x ) (d - d )
3

P x
s =
0.5 b x - n A (d - x ) - n A (d - x )
2

Entonces, teniendo en cuenta que:


P = P 1 + n A A1 + eI = 30500 kN

M = 16250 kNm
y suponiendo una cuanta de armadura pasiva, se puede obtener la tensin de sta.
Supondremos que se disponen 50f20 (f20 cada 20 cm), lo que supone una armadura pasiva de rea
total A = 15700 mm .
Con estos valores se obtiene los siguientes resultados:
x = 467 mm
s = 13.45 MPa
s = 53.0 MPa
Ds = 34.28 MPa
Se procede entonces a comprobar que la abertura de fisura w es inferior al lmite establecido de 0.1
mm.
w = bs e
b = 1.7, para acciones directas
s = 2c + 0.2s + 0.4 k f AA (separacin media de fisuras)
c = 40 mm (recubrimiento de las armaduras de traccin)
s = 200 mm < 15f = 300 mm (distancia entre barras longitudinales)
2

c
s

sm

c,eficaz

Los autores, 1998; Edicions UPC, 1998.

294

Hormign armado y pretensado. Ejercicios

k = 0.125
A = 15700 mm
A = (50+150)10000 = 2000000 mm
f = 20 mm
1

c,eficaz

s = 247.4 mm
s
e =
E 1 - k
m

sm

s

s

sr

(alargamiento medio de las armaduras)

k =1
s = 53.0 MPa
f = 0.30f = 3.51 MPa
P = P = 29757.5 kN
M = f + AP Ih = 7717.7 kN m

2
s
M
7717
.
7
=
s
M = 16250 = 0.477
E = 200000 MPa
53 [1 - 1 0.477 ] = 2.0510
e =
200000
que es superior a 0.4s /E = 1.0610 .
Por lo tanto, la abertura caracterstica de fisura es:
w = 1.7247.42.0510 = 0.0862 mm
que se aproxima bastante al lmite impuesto de 0.1 mm.
As pues, se puede adoptar como armadura pasiva 50f20 (A =15700 mm ) y como armadura activa
11T19f0.6 (A = 29260 mm ).
Verificada la condicin relacionada con el estado lmite de fisuracin, queda comprobar el no
agotamiento frente a solicitaciones normales. Se procede de forma anloga a la seguida en los casos
anteriores. No obstante, en este caso se conoce la armadura pasiva que se dispone, por lo que se
puede tener en cuenta en el clculo del momento ltimo de la seccin en rotura.
2

2/3

ct,m

ck

fis

ct ,m

sr

fis

-4

sm

-4

-4

Los autores, 1998; Edicions UPC, 1998.

295

E.L.U. servicio

M = 0.85 f b y d - y2 + A f (d - d )

P = 0.85f by - DT - A f
u

cd

cd

yd

yd

En este caso, la profundidad del bloque de compresiones en rotura es:


500
29260 1700
+ 15700
f + A f
A
1
.
15
1
.15 = 220.9 mm
y = 0.85 f b =
40
0.85 1.5 10000
x = 1.25y = 276.2 mm
El momento ltimo de la seccin es:

M = 0.85 140.5 10000 220.9 650 - 2202 .9 + 15700 1500


100 10 = 27698 kN m que
es
.15

superior al momento de clculo: M = 22687.5 kNm.


En cuanto a la verificacin de la hiptesis de plastificacin de la armadura activa, se obtiene:
e = 7.3910
e = 5.0910
De = 4.7410
e = 7.3910 < e + De = 5.0910 +4.7410 = 9.8310
El momento ltimo que resulta de considerar el pretensado nicamente, sin tener en cuenta la
armadura pasiva que se dispone, es M =23988 kNm, que es tambin superior al momento de
clculo. No obstante la armadura pasiva es necesaria para el control del ancho de fisura.
p

pyd

yd

cd

-6

pyd
Pn

pyd

-3

-3

-3

-3

Pn

-3

-3

Los autores, 1998; Edicions UPC, 1998.

-3

297

E.L.U. servicio

Ejercicio II-18 Deformabilidad de forjados pretensados

Un forjado de edificacin de 6.0 m. de luz est constituido por viguetas autorresistentes de


hormign pretensado simplemente apoyadas, separadas 70 cm entre ejes, bovedilla cermica como
elemento aligerante y capa de compresin superior de 4 cm. de hormign, que no se considera a
efectos de clculo resistente del forjado. El esquema estructural longitudinal y la seccin transversal
de la vigueta son los que se indican en las figuras adjuntas.
A=112.5 cm4 2
I =3800 cm
v=9.60 cm
v=8.40 cm
e=- 2.0 cm

Las propiedades de los materiales son las siguientes:


- hormign: HP-35/S/12/I, (fck= 35 MPa, a los 28 das)
- armaduras activas: Alambres de f=4 mm. de acero superestabilizado ( r=8%),
de fpyk = 1700 MPa, y fpu = 1900 MPa., tesados a una tensin spo = 0.75 fpu.
Las cargas a considerar son las siguientes:
- peso propio de la vigueta: 0.3 kN/ml
- cargas muertas (bovedillas, losa de compresin y solado) 1.0 kN/ml
- sobrecargas de uso: 1.5 kN/ml
La vigueta se pretensa a los 7 das del hormigonado, suponindose que en ese instante acta el peso
propio. No se efecta curado al vapor. A los 90 das se colocan el resto de cargas permanentes y se
supone que la sobrecarga acta a largo plazo.
Se pide:

1. Calcular la contraflecha de la vigueta al transferir el pretensado y a los 90 das.

Los autores, 1998; Edicions UPC, 1998.

298

Hormign armado y pretensado. Ejercicios

2. Calcular la flecha a largo plazo debida a las cargas permanentes y a las cargas totales.
3. Calcular la flecha activa.
Se utilizarn los coeficientes de fluencia y retraccin propuestos en la instruccin EHE,
considerando una humedad relativa del 70%. Se desprecian las prdidas por relajacin del acero de
pretensado desde el tesado hasta la transferencia.
Nota:

Solucin

En primer lugar se calcula la fuerza de pretensado al inicio de cada fase:


- inicial, al tensar los alambre en bancada
- al transferir el pretensado a la vigueta, a los 7 das
- a los 90 das
- a largo plazo
Pretensado inicial: P0 = ApsP0
2
A p = 6 p 4f = 6 p4 16 = 75.36 mm 2
sP0 = 0.75fp,mx = 0.751900 = 1425 MPa
P0 = ApsP0 = 75.361425 = 107388 N
Pretensado a los 7 das: Pk7 = P0 +DP3, siendo DP3 las prdidas por acortamiento elstico al
transferir.
A E
DP3 = s cp p p = - 6555 N
E c,7
Ep = 200000 MPa
= 23823 MPa
Ec,7 = b7Ec,28 = 0.8029779
Ec,28 = 8500fcm,281/3 = 8500(35+8)1/3 = 29779 MPa
Para el clculo de la tensin scp que el pretensado produce en la fibra del hormign en contacto con
el centro de gravedad de la armadura de pretensado debe utilizarse la seccin homogeneizada. No
obstante, las caractersticas de esta son casi idnticas a las de la seccin bruta, debido a la reducida
cuanta de armadura.
P P e 2 - M pp e = - 10.36 Mpa
s cp = - 0 - 0
A I
I
e =excentricidad del pretensado equivalente = yp = - 2.0 cm
2
M pp = 3008 4 = 600 N m
Pk7 = P0 + DP3 = 107388-6555 = 100833 N

Los autores, 1998; Edicions UPC, 1998.

299

E.L.U. servicio

Pretensado a los 90 das: Pk90 = Pk7 + DP790; es decir, tras las prdidas diferidas entre los 7 y los
90 das.
DP790 =

j(90,7) s cpg + E p e r (90,7) + 0.80 Ds pr


2
Ap
Ac y p

[1 + c j(90,7 )]
1+ n
1+

Ac
Ic

Ap

= - 19354 N

donde:
los coeficientes de fluencia j(90,7) y retraccin ecs(90,7) se obtienen segn el artculo 39 de la
Instruccin EHE, considerando una humedad relativa del 70% y un espesor ficticio de e = 2A/u =
45 mm, siendo la resistencia caracterstica del hormign fck = 35 MPa:
j(90,7) = 1.87
ecs(90,7) = -2.9510-4
n = Ep/Ec,7 = 8.4
La tensin scgp, bajo cargas permanentes en la fibra de hormign en contacto con el centro de
gravedad de las armaduras es:
P P e 2 - M pp e = - 9.71 MPa
s cgp = - k 7 - k 7
A
I
I
P
-100833
Ds pr = r f ki = 0.08
Ap
75.36 =- 107.04 MPa
c = 0.8
Pk90 = Pk7 + DP790 = 100833-19354 = 81479 N
Pretensado a largo plazo: Pk = Pk7 + DP7,; esto es, tras las prdidas diferidas totales.
DP7 =

j(10 6 ,7) s cpg + E p e r (10 6 ,7 ) + 0.80 Ds pr


1

+n

Ap
Ac

A c y 2p
1 +

Ic

[1 + c j(10 6 ,7 )]

j(106,7) = 3.01
ecs(106,7) = - 4.0210-4
n = Ep/Ec,7 = 8.4
P P e 2 - M pp+cm e
s cgp = - k 7 - k 7
A
I
I

Ap

= - 8.66 MPa

Mpp+cm = 2600 Nm
P
-100833
Ds pr = r f ki = 0.08
Ap
75.36 =- 107.04 MPa
c = 0.8

Los autores, 1998; Edicions UPC, 1998.

= - 23889 N

300

Hormign armado y pretensado. Ejercicios

Pk = Pk7 + DP7 = 100833-23889 = 76944 N


En las siguientes figuras se recoge el estado tensional en la seccin de centro de luz a diferentes
edades.

A la vista de los diferentes estados 2/3tensionales, y dado que se considera una resistencia caracterstica
a traccin de valor fct,k = 0.21fck = 2.25 MPa, se observa que ninguna seccin fisura. Por lo
tanto, a la hora de calcular las flechas se tendr en cuenta la inercia no fisurada.
1 Contraflecha al transferir (t= 7 das):

Las acciones actuantes son el pretensado a los 7 das (Pk7 = 100833 N) y el peso propio (pp = 0.30
kN/m = 0.3 N/mm).
La flecha se calcula como:
5 pp l 4 + Pk 7 e l 2 = 1.10 - 4.45 = -3.35 mm
d 7 = d 7pp + d P7 =
384 E c,7 I 8 E c,7 I
k7

Contraflecha a los 90 das


Esta flecha se calcula como suma de
la instantnea anteriormente calculada
y la diferida debida al efecto de la
fluencia de las cargas permanentes: d90
= d7 + d790

Los autores, 1998; Edicions UPC, 1998.

301

E.L.U. servicio

pp + Pk 90 l = -2.5 0.66 = -1.67 mm


d 7 90 = d ins
x
x(90) - x( 7 )
1.0 - 0.26 = 0.66
l=
=
=
,
,
1 + 50 r 1 + 50 r 1 + 50 0.0022
A, 25.12 = 0.0022
r, = p =
A c 11250
d 90 = -3.35 - 1.67 = -5.02 mm

Para el clculo de d + se debera utilizar un valor medio de Pk, entre Pk7 y Pk90, puesto que la
prdida de pretensado se va produciendo poco a poco. No obstante, la Instruccin EHE dispone que
se ha de considerar la fuerza de pretensado final. Dado que de esta forma quedamos del lado de la
seguridad, se utiliza Pk90:
2
4
pp P = 5 pp l + Pk 90 e l = -2.5 mm
d ins
384 E c,7 I 8 E c,7 I
pp Pk 90
ins

k 90

2 Flecha a largo plazo debida a cargas permanentes y totales:

La historia de cargas permanentes actuantes sobre la estructura es la siguiente: a los 7 das acta el
pretensado y el peso propio, mientras que las cargas muertas lo hacen a partir de los 90 das. Las
sobrecargas de uso actan a largo plazo.
La flecha a largo plazo que provocan estas cargas son suma de la instantnea que provoca cada una
de ellas ms la diferida de las cargas permanentes debida al efecto de la fluencia.
Flecha a largo plazo debida a las cargas permanentes

Anteriormente se ha visto que las flechas instantneas debidas al pretensado y al peso propio son las
siguientes:
d 7pp = 1.1 mm
d 7 = 1.10 - 4.45 = -3.35 mm

Para el calculo de la flecha diferida debida al peso propio se considera la siguiente expresin:
d pp = l d 7 = 1.568 ( -3.35) = -5.253 mm
x
x() - x( 7 )
2.0 - 0.26 = 1.568
l=
=
=
,
,
1 + 50 r 1 + 50 r 1 + 50 0.0022

Por lo tanto, la flecha total debida al peso propio y al pretensado, ambos actuantes desde los 7 das,
es:
dpp+Pk = d7 + d + = (1.1 - 4.45) 5.253 = - 8.6 mm (contraflecha)
pp Pk
7

Los autores, 1998; Edicions UPC, 1998.

302

Hormign armado y pretensado. Ejercicios

Por lo que se refiere a la flecha debida a la carga permanente:


5 cm l 4 = 2.7 mm
d cm
90 =
384 E c,90 I
Ec,90 = b90Ec,28 = 1.09 29779 = 32459 MPa n = 6.16
cm
d cm
90 = d ins l = 2.7 0.9 = 2.43 mm
x
x( ) - x(90 )
2.0 - 1.0 = 0.9
l=
=
=
,
,
1 + 50 r 1 + 50 r 1 + 50 0.0022

La flecha debida a la carga muerta es, finalmente:


dcm = 2.7 + 2.43 = 5.13 mm
La flecha a largo plazo debida a la totalidad cargas permanentes es:
dG = - 8.6 + 5.13 = - 3.47 mm
Flecha debida a las cargas variables

Las sobrecargas de uso nicamente provoca flechas instantneas de valor:


5 sc l 4 = 3.8 mm
d sc = d scins =
384 E c, I
Ec, 1.16Ec,28 = 34544 MPa

Flecha a largo plazo debida a la totalidad de las cargas

La flecha total se obtiene como suma de las anteriores:


d TOT = d G + d sc = -3.47 + 3.8 = 0.33 mm
3 Flecha activa:

La flecha activa es la producida a partir del instante en que se construye el elemento estructural
considerado, en este caso las cargas muertas. Se calcula como la flecha total menos la que se ha
producido hasta el instante en que se construye el elemento, en el ejemplo hasta los 90 das.
d act = d TOT - d 90 = 0.33 - ( -5.02) = 5.35 mm

lo que representa una fraccin 1/750 de la luz, que es muy razonable.

Los autores, 1998; Edicions UPC, 1998.

Elementos estructurales

303

BLOQUE III Elementos estructurales

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

305

Ejercicio III-1 Pasarela peatonal postensada

Para atravesar una lnea de ferrocarril en Granollers (en zona urbana) se quiere construir una
pasarela peatonal, cuya estructura bsica est compuesta por unos soportes de hormign armado y
un dintel de hormign pretensado. ste ltimo es una viga apoyada en los soportes, con una luz de
clculo de 30 m y una seccin constante en cajn. Ver figura adjunta (cotas en metros).

Se tiene intencin de efectuar el postensado mediante tendones formados por 9 cordones de f0.6
(1260 mm /tendon, dimetro de vaina 63 mm).
El acero de pretensado ser de tipo Y1860 S7. La penetracin de cua estimada es de 4 mm. El
coeficiente de rozamiento en curva m=0.20. El coeficiente de rozamiento parsito por ondulacin
parsita k/m=0.01 rad/m. La relajacin total prevista es del 7%.
Las acciones previstas sobre la plataforma son:
- carga permanente repartida (pavimento y barandilla) 3.0 kN/m ,
- sobrecarga variable formada por una carga uniformemente repartida de 5.0 kN/m y una
carga puntual mvil de 50 kN. Se utilizan los coeficientes (Y = 0.6, Y = 0.5, Y =
0.3).
El control de la ejecucin ser de tipo intenso.
Se considera un hormign H-45 en ambiente IIa. Considrese un coeficiente de fluencia j=1.50 a
tiempo infinito y un valor para la retraccin final de 0.2 mm/m. El acero a emplear para las
armaduras pasivas ser B500S.
2

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

306

Se pide:

1. Dimensionamiento del pretensado de la viga.


2. Calcular la armadura pasiva longitudinal.
3. Calcular la armadura pasiva transversal.
4. Determinacin de la armadura transversal en las alas.
5. Determinacin de la armadura transversal en el tablero superior entre almas.
6. Disposicin de armaduras.
Solucin

1 Dimensionamiento del preten sado de la viga


1.1 Caractersticas geomtricas d e la seccin

Las caractersticas geomtricas de la seccin bruta de hormign se evalan como:


- rea : A = 1.196 m ,
- altura del centro de gravedad: y = 0.952 m (desde la fibra inferior),
- momento de inercia respecto al centro de gravedad: I = 0.314 m ,
- radio de giro de la seccin (r =I/A): r=0.512 m,
- distancia del centro de gravedad a la fibra inferior: v=0.952 m,
- distancia del centro de gravedad a la fibra superior: v=0.548 m,
- lmite superior del ncleo central: c=r /v=0.275 m,
- lmite inferior del ncleo central: c=r /v=0.478 m.
2

1.2 Clculo de las leyes de esfuer zos

La pasarela se estudia como viga biapoyada de 30 metros de luz. Las leyes de momentos flectores
para cada una de las solicitaciones resultan:
- Peso propio (g =29.9 kN/m)
M = 448.50x - 14.95x M = 3363.75 kN m
- Carga permanente (g =8.4 kN/m)
M = 126.00x - 4.2x M = 945.0kN m
1

g1

g1CL

g2

g 2 CL

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

307

- Sobrecarga repartida (sc=14 kN/m)


M = 210.00x - 7.0x M = 1575.0kN m
- Envolvente carga puntual
M = 50.00x - 1.667x M = 375kN m
2

sc

g1CL

QCL

en donde x est en metros. Los momentos flectores mximos se obtienen en la seccin de centro de
luz.
1.3 Criterio de dimensionamient o

Situacin en vaco. Los esfuerzos actuantes son los debidos a la accin del pretensado y al peso
propio. Se tiene que verificar que las compresiones mximas en esta fase (en la fibra inferior) sean
menores que 0.6f , en donde f es la resistencia caracterstica del hormign el da (j) de tesado.
Igualmente es recomendable evitar la presencia de tracciones en el hormign en esta fase (en la fibra
superior). Para cualquiera de estas dos condiciones la fuerza de pretensado es desfavorable, por lo
que debe considerarse su valor caracterstico inicial (descontando prdidas instantneas)
multiplicado por g (con g =1.1 para armadura postesa).
El criterio de que no existan tracciones en la seccin se traduce en que la excentricidad (e) del
centro de gravedad de las armaduras activas respecto del centro de gravedad de la seccin quede
limitado por:
e = c + MP
ckj

ckj

mx

en donde en nuestro caso: M = M ; P = 1.1P


Situacin de servicio. La situacin ms desfavorable en servicio corresponde a la situacin de
tiempo infinito. Los esfuerzos que deben considerarse en el dimensionamiento son los debidos a la
accin del pretensado y a las acciones exteriores.
Se debe verificar en servicio que las compresiones mximas no superen el valor de 0.6f , para
evitar la microfisuracin longitudinal del hormign. Es recomendable realizar esta comprobacin
para la combinacin poco frecuente de acciones. Igualmente (ambiente IIa) debe verificarse que para
la combinacin frecuente de acciones el ancho de fisura sea menor que 0.2mm (y adicionalmente
que las armaduras activas estn en la zona comprimida de la seccin). Como sea que con esta
condicin es difcil dimensionar la estructura es recomendable dimensionarla con el criterio de que
la mxima traccin no supere el valor de la resistencia caracterstica del hormign a traccin.
Para cualquiera de estas dos condiciones la fuerza de pretensado es favorable por lo que la situacin
crtica se produce a tiempo infinito. La fuerza de pretensado debe calcularse descontando prdidas
instantneas y diferidas y debe afectarse por el factor g = 0.9. El criterio de que la tensin mxima
de traccin sea menor que f se traduce en que el centro de gravedad de las armaduras activas tenga
una excentricidad mnima dada por:
1

g1

ki

ck

ctk

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

308

min

= -c +

M -f I
P
v P

(1)

ctk

en donde M es el momento debido a la combinacin frecuente de acciones y en donde P =0.9P ,


con P = fuerza de pretensado a tiempo infinito. Alternativamente, una condicin ms o menos
equivalente, y ms til para el predimensionamiento es:
e = -c + MP
(2)
2

min

en donde P =P . Posteriormente se comprueba si con g = 0.9 se verifica que las tensiones de


traccin son admisibles.
Las condiciones de excentricidad mnima y mxima definen el ncleo lmite (la zona por la que debe
moverse el centro de gravedad de las armaduras activas). El dimensionamiento ptimo se obtiene
cuando e = e , siempre que sea posible dar esa excentricidad al cable dentro de la seccin y
respetando los mrgenes de recubrimiento. Imponiendo la condicin anteriormente mencionada a la
ecuaciones (1) y (2) se obtiene que:
~
(3)
P M - M c++(1c- a) M
en donde:
P = Pa
y ~a = 1a.1
Es habitual tomar a 0.800.85 ( entre un 15% y un 20% de prdidas diferidas respecto de la
fuerza instantnea de pretensado). En nuestro caso tenemos:
M = 3363.75 kNm = 3364 kNm
M = 3364+945+0.5(1575+375) = 5284 kNm
(combinacin frecuente)
c = 0.276 m
c = 0.479m
a=0.80
0.80 = 0.73
~
a=
1.1
2

mn

mx

ki

1
2

Resolviendo la ecuacin (3) se obtiene:


+ (1 - 0.73)3364
P 5284 - 3364
= 3746 kN
0.276 + 0.479
e = e = -c + MP = -c + M
P = 1.12 m
k

mn

mx

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

309

Debemos incrementar la fuerza de pretensado para que la e caiga dentro de la tabla inferior. La
excentricidad que podemos colocar es e=0.852 m. Imponiendo:
e = 0.852 = -c + MP P = P > 4684 kN
mn

min

Tomaremos (para poder verificar que las armaduras activas queden dentro de la zona comprimida)
un valor algo superior, P = 4800 kN.
Con esta fuerza de pretensado evaluamos:
P = 4800
0.80 = 6000 kN
P = 6000
0.90 = 6670 kN @ 6.7 MN
k

ki

Predimensionamos las armaduras activas tomando:


s = min ( 0.9 f ,0.75 f
) = 1395 MPa
p

pyk

p mx

de este modo obtenemos:


A > 47.81 cm
p

34.2f0.6

Decidimos colocar 4 tendones formados por 9 cordones 0.6, con un rea total de 50.4 cm . El
dimetro de la vaina (63 mm) permite la excentricidad que se ha adoptado, pues podemos alojar los
tendones con un recubrimiento algo mayor al dimetro de la vaina en la losa inferior.
2

1.4 Comprobaciones preliminare s

Antes de continuar adelante debemos comprobar preliminarmente (para ver que todo es correcto) las
condiciones del dimensionamiento con los valores provisionales de la fuerza de pretensado.
1.4.1 Vaco

Tomamos como datos para la seccin centro de luz:


v
v

c
c

e P M

e = 0.852 m
P = 1.1P = 6600 kN
M = 3364 kNm
1

ki

Comprobamos tensiones en la fibra superior e inferior:

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

310

6.6 + (-6.6 0.852 + 3.364 ) 0.548 = 1.58 MPa > 0


1.196
0.314
( corrrecto)
0.852 - 3.364 ) 0.952
6
.
6
(
6
.
6
s
=
+
= 12.37 MPa < 0.6 f
1.196
0.314
La resistencia mnima necesaria en el instante de tesado es 12.37/0.60=20.7 MPa. Para un
hormign de 45 MPa de endurecimiento normal se tiene a los 7 das aproximadamente
0.6545=29.3 MPa, por lo que el tesado puede efectuarse sin problemas a los 7 das.
s

c,sup

c,inf

ck , j

1.4.2 Servicio

Tomamos como datos para la seccin de centro de luz:


M = 5284 kNm ( frecuente)
v
M = 6259 kNm ( poco frecuente)
c
M
M
= 4309 kNm ( bajo carga permanente)
e P
c
=
0.9P = 4.32 MN
P
v
2
2

Comprobaremos tensiones en fibra superior (con momento de la combinacin poco frecuente) y en


la fibra inferior (con momento de la combinacin frecuente):
4.32 + (-4.32 0.852 + 6.259 ) 0.548 = 8.11 MPa < 0.6 f = 15 MPa > 0
s
=
1.196
0.314
4
.
32
(
4
.
32
0.852 - 5.284 ) 0.952
s
=
= -1.25 > - f = -0.21 f = -2.6 MPa
1.196 +
0.314
c,sup

ck , j

c,inf

ct ,k

ck

Miramos, por ltimo, las tensiones en la vaina ( y=0.88 m):


4.32 + (4.32 0.852 - 5.284) 0.88 = -0.88 MPa
s
=
1.196
0.314
En este caso, sta es la condicin crtica (pues la vaina nos sale ligeramente traccionada). Es
necesario incrementar ligeramente la fuerza de pretensado a tiempo infinito. Seguimos no obstante
adelante esperando que la estimacin de prdidas diferidas que hemos hecho (20%) sea demasiado
pesimista.
Observemos que el incremento de tensin a nivel de la armadura activa debida a la accin de la
combinacin frecuente es:
(5.284 - 3.364 ) 0.852 E @ 30 MPa
Ds =
0.314
E
c,vaina

EHE observa que si este incremento es inferior a 200 MPa se supone que no se ha alcanzado un
ancho de fisura superior a 0.2 mm.

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

311

1.5 Trazado de las armaduras ac tivas

En la seccin de anclajes es vlido en principio cualquier trazado que est dentro del ncleo central.
Tomaremos una excentricidad en al seccin de apoyo de e=0.202m.
Este trazado tiene la ventaja de que puede conseguirse de manera que dos de los tendones se muevan
nicamente por el plano del alma y los otros dos por la tabla inferior anclndose ambos en las zonas
de mayores dimensiones para que sea posible dimensionar correctamente las zonas de anclaje.
Trazados con ms pendiente son ms ventajosos frente al cortante, pero a costa de mayores prdidas
de rozamiento.
El trazado queda definido por:
e(x) = - 0.002889x + 0.086667x + 0.202
2

1.6 Clculo de las prdidas de pr etensado

La fuerza de tesado se ha evaluado preliminarmente como P = 6.70 MN. Evaluamos ahora las
prdidas instantneas y diferidas para verificar correctamente las condiciones de
predimensionamiento.
0

1.6.1 Prdidas de rozamiento

Las perdidas de rozamiento vienen dadas por:


P (x ) = P e
m = 0 .2
k = 0 .002
a(x) se puede tomar como la integral en valor absoluto de la curvatura, luego en nuestro caso a(x)
= 5.77710 x
Con esto se obtiene en la seccin centro de luz:
P = 0.954P
DP = 0.046P = 310 kN.
- ( m a + k x )

-3

1.6.2 Prdida por penetracin de cua

La longitud afectada por la penetracin de cua se evala como:


l

E A a
lP
p

En donde l = 5.77710 0.2 + 0.002 = 0.0031 m .


-3

-1

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

312

Resolviendo se obtiene l = 13.93 m. Con este valor se tiene P (l )= 0.958 P , por lo que la
prdida en anclajes es:
DP = 2 (1 - 0.958) P = 0.085 P = 566 kN
p

Las prdidas de penetracin de cua no afectan a la seccin de centro de luz.


1.6.3 Prdidas por acortamiento elst ico

Se supone que los cuatro tendones se tesan sucesivamente (n=4), calculndose las prdidas como:
n -1 s A E
DP =
2n
E
p

cp

cj

en donde E es el mdulo de deformacin longitudinal del hormign en el instante de tesado y s es


la tensin en el momento de tesado en el centro de gravedad de las armaduras activas (calculndose
con P ). Para la seccin de centro de luz se tiene:
P = 6700 - 310 = 6390 kN
6.39 6.39 0852 3.364 0852
s =
1.196 + 0.314 - 0.314 = 11 MPa
E = 35 kN / mm
cj

cp

cp

cj

Resolviendo se obtiene: DP =119 kN.


La prdida instantnea en centro de luz resulta DP =310+119 =429 kN, aproximadamente un
6.4% de la fuerza de tesado ( P ). Tenemos por lo tanto P =6271 kN.
Esta fuerza es ligeramente superior a la estimada inicialmente. No obstante cuando se comprueban
tensiones en vaco con este nuevo valor no se presenta ningn problema.
3

ki

1.6.4 Clculo de las prdidas diferida s

Se calculan las prdidas diferidas mediante la siguiente expresin (compresiones y contracciones


negativas):
n j s + E e + 0.8 Ds A
DP =
1 + n AA .1 + A I y (1 + c j)
cgp

dif

pr

donde s es la tensin en el hormign en la fibra correspondiente al centro de gravedad de las


armaduras activas debida a la accin del pretensado, el peso propio y la carga muerta; n es la
relacin entre mdulos de deformacin longitudinal del hormign y del acero de pretensado; j es el
coeficiente de fluencia previsto para la edad de puesta en carga igual a la edad de tesado; e es la
cgp

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

313

retraccin prevista; Ds es la prdida por relajacin del acero prevista; y (e(x)) es la excentricidad
de la fibra correspondiente al centro de gravedad de las armaduras activas; y c es el coeficiente de
envejecimiento. La relajacin se calcula a partir de la siguiente expresin:
P
Ds = r
A
pr

pr

donde r es el coeficiente de relajacin y P es la fuerza de pretensado tras las prdidas instantneas.


Se tiene para la seccin de centro de luz:
6.27 6.27 0.852 - 4.309 0.852 = 8.0 MPa
s =
1.196 +
0.314
DP = 741 kN
Tenemos por lo tanto P =5530kN. Este valor es claramente superior al valor determinado
anteriormente. Recomprobando la condicin de que la vaina queda comprimida tenemos:
0.9 5.53 + (0.9 5.53 0.852 - 5.284 ) 0.88 = 1.23 MPa
s
=
1.196
0.314
por lo que la vaina queda comprimida.
Las comprobaciones preliminares efectuadas anteriormente son por lo tanto vlidas.
f

cgp

dif

c,vaina

2 Clculo de la armadura pasiv a longitudinal

Se ha dimensionado el pretensado para ELS. Debe ahora comprobarse el ELU de agotamiento por
solicitaciones normales.
Las caractersticas resistentes de los materiales se toman como:
f = 30 MPa
f = f /1.15=0.91860/1.15 = 1455 MPa
cd

yd

yk

2.1 Momento de clculo (Md)

El momento de clculo se evala como:


Md

= g G (M g1 + M g 2 ) + g Q ( M SC + M Q )

en donde al tener las acciones variables el mismo origen no se reducen por el coeficiente de
combinacin. Se utiliza g =1.35 y g =1.50, correspondientes a control intenso. Para la seccin
centro de luz resulta:
G

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

314

M = 1.35(3364+945)+1.5(1575+375)=8742 kNm
d

2.2 Clculo del momento ltimo (Mu)

Suponiendose que la seccin rompe de manera dctil plastificando la armadura activa, se tiene:
f = 1455 MPa
P = 1455 50.4 10 =7.33 MN
Esta traccin debe equilibrarse con compresiones en el hormign. Suponiendo que estas
compresiones se reparten en la losa superior se tiene un bloque de compresiones de:
0.85 f b y = P y = 0.10 x = 0.128 m
pyd

-4

cd

con lo que la cabeza de compresiones no sobrepasa la losa superior.


El momento ltimo resulta:
M = 7.33(1.40 - 0.05) = 9.89 MN > M
u

por lo que la seccin resiste sin necesidad de aadir armadura pasiva:


Falta nicamente comprobar que la rotura es dctil para lo que debe verificarse si la deformacin
total del acero de pretensado es mayor que la deformacin correspondiente al lmite elstico:
e = e + De > e = 0.00837
p

pu

pyd

en donde e es la deformacin correspondiente a la fuerza de neutralizacin y De es tal que:


pn

cu

De
d -x
p

Calculando se obtiene De = 0.0348, claramente superior a e por lo que la rotura seguro que es
dctil.
p

pyd

2.3 Dimensionamiento

La nica armadura necesaria lo ser nicamente por condicionantes de armadura mnima. Se


dispondr una armadura que, para acero f =500 MPa, resulta:
A = 0.0028 A
30 0.0028 A
A = 100
yk

s,min

s,min

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

315

Por tanto:
A =33.5 cm , traccin
A =9.569 cm , compresin
Se opta por colocar barras de 12 mm de dimetro alrededor de toda la seccin, separadas 30 cm una
de otra, tanto en el permetro exterior como en el interior.
2

s,min

s,min

3 Dimensionamiento de la arm adura pasiva transversal


3.1 Leyes de clculo

Evaluamos los cortantes nicamente en la seccin de apoyo.


Tenemos:
g = 29.9 kN/m
V = 448.5 kN
g =8.4 kN/m
V = 126 kN
SC = 14 kN/m
V = 210 kN
Q = 50 kN
V = 50 kN
Obtenemos, combinando en ELU:
V = 1.35(448.5+126) + 1.5(210+50) = 1166 kN
Este cortante se puede reducir con el valor de la componente vertical del pretensado, quedando:
V = 1166 - Psen a = 1116 5530sen(4.953) = 688 kN
1

g1

g2

SC
Q

rd

3.2 Dimensionamiento

En primer lugar se comprueba la capacidad resistente de las bielas comprimidas. Para ello se evala
V.
+ cot a
V = K f b d cot1 +qcot
q
u1

u1

1cd

en donde:
dimetro de las vainas 6.3 cm
b = b - hf = 33.7 cm = 0.337 m
0

f1cd

= 0.6 fcd = 18 MPa

(h = 0.50)

d=1.45 m
a=0

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

316

K = 53 1 + sf

'
cd

cd

>/ 1.00

Tomamos s = PA = -4.6 MPa ( signo negativo para compresiones).


Elegimos el ngulo de inclinacin de las bielas de manera que coincida con el que se produce
elsticamente; esto es:
k

cd

cot q = cot q

1 - fs

xd

= 1.49

ct ,m

en donde s =- 4.6 MPa y


xd

f ct ,m

= 0.30

f ck

= 3.79 MPa

Obtenemos por lo tanto K=1.4 (tomando K=1) por lo que:


V = 8.796 0.46 = 4.07 MN > V
u1

(correcto)

rd

Para dimensionar la armadura transversal necesaria: V = V + V . Se tiene:


u2

Vcu

0.1

x (100 r f
l

cu

su

) - 0.15 s ) b d b
1/ 3

ck

cd

en donde:
200 = 1.37
d
f
A f
r =
b d = 0.97
s = -4.6 MPa
b =1
(al ser cot q = cot q )
x =1+

yp

yd

cd

luego, V = 623 kN. De aqu, V = V V = 65 kN, y se deduce Aa:


65000N = A f 0.9 d cot gq ,
donde f a = 400 MPa,
luego Aa = 0.83 cm /m 2 cercos f8 a 0.20 ( A =10.05 cm /m)
La cuanta mnima debe ser:
cu

su

rd

cu

ya,d

,d

real

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

A f
a

ya

317

0.2 + 0.75 b A a
20

ck

,min

= 3.37 cm

/m

por lo que la armadura dispuesta es superior.


4 Determinacin armadura tra nsversal en las alas

La armadura transversal en las alas debe cubrir los estados lmites de flexin transversal, cortante y
rasante ala-alma.
4.1 Flexin

Cuando la carga se sita en las alas de la pieza se generan esfuerzos locales para los que debe
armarse la seccin. El ala tiene seccin variable, cuyo canto queda definido por la siguiente
ecuacin: h = 0.15 m + x/7, donde x es la distancia desde el extremo de la seccin hacia el
interior.
Si se toma 1m de viga, los esfuerzos sobre la seccin de arranque del ala son los siguientes:
- peso propio (g =25 kN/m ):
pp = 25 0.15 + x7 x = 3.5 kN

M = 25 0.15 + x7 (0.7 - x ) x = 1.12 kN m

- carga permanente (g =3 kN/m ):


M = 3 0.7 m 1 m 0.35 m = 0.735 kNm
- sobrecarga variable repartida (sc=5 kN/m ):
M = 5 0.7 m 1 m 0.35 m = 1.225 kNm
- carga puntual (50 kN). Repartimos el momento debido a la carga puntual en una distancia
de 0.70m (reparto aproximado a 45). Tenemos:
M=50 0.7 0.7=50 kNm
La combinacin de esfuerzos nos da el siguiente momento de clculo:
M =1.35(1.12+0.735)+1.5(50+1.225)=79.3 kNm
El dimensionamiento a flexin se realiza a continuacin:
U =0.85f bd =5610 kN/ml
siendo d=0.22 m
M = 0.375U d=463 kNm/ml
3

x = 0.7

x=0

x = 0.7

pp

x =0

cp

cv

cd

lim

Se tiene M < M
d

lim

lim

= 1

1 - U2M d d = 0.0146 m
d

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

318

z=0.22 y /2 = 0.213 m
U = Mz = 373 kN / ml
A = 8.58 cm /ml (f16 cada 20 A =10.05 cm /ml)
lim

s1

4.2 Cortante en las alas

El cortante de clculo, a partir de los esfuerzos antes deducidos, se obtiene efectuando la


combinacin correspondiente (por metro lineal):
V = 3.5 kN
V = 2.1 kN V = 1.35 (3.5 + 2.1) + 1.5 (50 + 3.5) = 87.8 kN
V = 3.5 kN
V = 50 kN
pp

cp

cv
Q

El ala tiene canto variable, luego hay una reduccin de esfuerzo por la inclinacin de la cabeza
comprimida:
a

Nsd, ( s)
Vrd

Ncd, (

ac)

N sen a + N sen a + V = V
V =V -V
sd

rd

cd

rd

cd

Por otra parte, M

= z N sd cos a s = z N cd cos a c , luego:

M (tana + tana ) , y si se acepta que tana tana , se tendr:


z
z
d
M
M
V = z tana + d tana
En este caso, a = 0 y a = 8.126, luego:
V = Md tana = 790..322mkN
m tan (8.126 ) = 51.5 kN , de donde V = 36.3 kN.
Si comprobamos los tirantes sin armadura de cortante tenemos:
V

cd

cd

rd

cd

Vu 2

0.12

x (100 r f
l

) - 0.15 s ) b d , donde:
1/ 3

ck

'

cd

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

319

8.58 = 0.0039
100 22
s = 0
200 = 1.95
x =1+
220

r =
l

cd

luego V = 110 kN > V , por lo que no es necesaria la armadura de cortante.


u2

rd

4.3 Rasante ala-alma

Simplificadamente (del lado de la seguridad) podemos evaluar el rasante ala-alma suponiendo que la
losa superior en la seccin de centro de luz est trabajando a su mxima capacidad. La diferencia de
compresin en la losa superior entre la seccin de centro de luz y la seccin de apoyo, se puede
repartir uniformemente en la distancia entre ambas secciones. Resulta:
F = (0.25 +2 0.15) 0.7 0.85 125
.50 = 1.98 MN
.98 = 0.132 MN = 132 kN / m
S = Fa = 115
d

Se debe verificar:
(correcto)
S S = 0.5 f h = 1.25 MN
S S = A f
(f = 400 MPa )
Aa = 3.3 cm /m a repartir entre armadura superior e inferior.
Como sea que esta armadura es inferior a la calculada para la flexin transversal se dispone la
calculada anteriormente 8.58 cm /ml, materializndose con f16 a 20.
d

u1

u2

lcd

ya

ya

5 Determinacin armadura tra nsversal en tablero superior entre almas

Tomando nuevamente 1 m de longitud de viga y suponiendo un esquema de viga biempotrada de


1.40 m de luz:
- Peso propio: 5 kN/m
M =- 0.82 kNm/ml
M =0.41 kNm/ml
- Carga permanente: 3 kN/m
M =- 0.49 kNm/ml
M =0.25 kNm/ml
- Sobrecarga variable repartida: 5 kN/m
M =- 0.82 kNm/ml
M =0.41 kNm/ml
-

Los autores, 1998; Edicions UPC, 1998.

Hormign armado y pretensado. Ejercicios

320

- Sobrecarga puntual: 50 kN (suponemos que afecta a una longitud de h = 70 cm)


M =- 12.5 kNm/ml
M =12.5 kNm/ml
La combinacin de estos esfuerzos proporciona los siguientes valores mximos:
M =- 21.7 kNm/ml
M = 20.3 kNm/ml
Resulta una armadura superior de 3 cm /m y una armadura inferior de 2.90 cm /m. Dispondremos
superiormente corrida la armadura determinada para el ala (f16 a 20). Inferiormente colocamos f10
a 20.
-

6 Esquema de armaduras

Con las armaduras obtenidas dibujamos los croquis de armaduras en la seccin central y en la
seccin de apoyos.
Ntese que se ha optado por mantener la cuanta de armadura transversal formada por estribos (que
ha sido realmente calculada en la seccin de apoyos) en toda la longitud del puente, siendo esto as
para que coincidan los planos de estribos con los de armadura transversal de la losa superior.
10 a 0.20

16 a 0.20

12 a 0.30
12 a 0.30

8 a 0.20

8 a 0.20

1c 8 a 0.20
12 a 0.30
12 a 0.30

8 a 0.20

010m
8 a 0.20
4t 90.6''

SECCIN CENTRO DE LUZ

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

321

10 a 0.20

16 a 0.20
0.10

12 a 0.30
12 a 0.30

8 a 0.20

8 a 0.20

1c 8 a 0.20
12 a 0.30
12 a 0.30

4t 90.6''

8 a 0.20

0.10
8 a 0.20

SECCIN APOYOS

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

Ejercicio III-2

323

Viga sometida a flexin y cortante. Dimensionamiento completo de


armaduras

Una viga de hormign armado de 13 m. de longitud total y seccin rectangular de 1.0 x 0.30 m se
encuentra simplemente apoyada en dos puntos como se muestra en la figura.

Las acciones que pueden actuar sobre la viga son:


- un descenso del apoyo B de 2 cm,
- una carga uniformemente repartida de 104 kN/M que puede extenderse de cualquier
forma,
- una carga puntual mvil de 80 kN.
Se considerar un nivel de control intenso.
Las caractersticas de los materiales son: HA-30/P/20/IIa; B400S
Se pide:
1. Dimensionar a flexin y cortante la armadura de la viga para los E.L.U.
Nota: las leyes de esfuerzos de clculo son las obtenidas en el ejercicio I-1.

Solucin
Seccin B (x = 10m)

(momentos negativos)

b = 0.30 m = 300 mm

Md = 473 kNm

h = 1.0 m = 1000 mm
f yd

f cd

400
1.15
30
1.5

= 348N / mm

= 20N / mm

= 0.9 h = 0.9 1000 mm = 900 mm


d

= 0.1h = 0.1 1000mm = 100 mm

Los autores, 1998; Edicions UPC, 1998.

324

Hormign armado y pretensado. Ejercicios

= 0.85f b y

M lim

cd

d
2

lim

lim

xlim = 0.6679d
ylim = 0.8xlim = 0.5343d
0.5343 900

= 0.85 20 300 0.5343 900 900 = 1617.5 kNm


2

M lim

Md =473 kN.m < Mlim = 1617.5 kNm

As = 0

Equilibrio
0 = 0.85 fcdby - Asfyd
Md = 0.85 fcdby(d-y/2)
y
d

=1-

2M d

0.85 f cd

bd

=1-

2 473 10

0.85 20 300 900

= 0.1219

Asfyd = 0.85 fcdbd(y/d)


As

0.85f cd

b d (y / d )

f yd

0.85 20 300 900 0.1219


348

= 1607.8 mm

Cuanta mecnica:

= 0.04 A

A smin

Cuanta geomtrica
A sg
Ac

f cd
c

= 0.04 1000 300

f yd

tipo viga

B400S

= 3.3 ,

20
348

= 689.6 mm

= 3.3

Asg=Ac3.3= 10003003.3=990 mm
2

As =1.607,8 mm > As,min = 689.6 mm ; As=1607.8 mm >Asg =990 mm


As

pf

= nf

f20 n 20 =

nf =

p 20

r = 25 mm

pf

4 1607 .8
2

f = b - 2(f

En una fila (2n-1)

4A s

= 5.1 6f20

+ r)

ambiente IIa

= 10

fck = 30 Mpa

f =300 2(10 + 25) =230 mm


f
n = 1 + 230/f
1
230
6.25 6f20 en una fila
= 1 +
2
f

(2n-1)

n-1 =230/
n

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

325

Comprobacin de canto til


dreal = h - dg

f/2 + 10 +25 = (20/2 + 10 + 25) mm = 45 mm

dg =

dreal = 1000 45 = 955 mm > dsupuesto = 900 mm


Tramo AB (x = 4.9 m) Md = 592 kN.m (momentos positivos)

= 0.85f b y

M lim

cd

lim

y lim
2

d = 900 mm

xlim = 0.6679d
y = 0.8xlim = 0.80.6679d = 0.5343d
0.5343 900

= 0.85 20 300 0.5343 900 900 = 1617.5 kNm


2

M lim

Md = 592 kNm < Mlim = 1617.5 kNm


Imponiendo equilibrio obtenemos

y
d

=1-

=1-

2M d

0.85 f cd

bd

As = 0

2 592 10

0.85 20 300 900

= 0.1554

Asfyd = 0.85 fcdbd(y/d)


As

0.85f cd

b d (y / d )
f yd

0.85 20 300 900 0.1554


348

= 2049.38 mm

Cuanta mecnica:

= 0.04 A

A smin

f cd
c

f yd

Ac
As

= 3.3
= nf

Pf2
4

B400S

= 689.6 mm

= 3.3

nf
2

4A s

Pf
Seccin central tramo AB
2

nf

16

11

20

25

(mm)

20
348

Asg = Ac3.3 = 10003003.3 = 990 mm

As =2049.38 mm

tipo viga

Cuanta geomtrica mnima


A sg

= 0.04 1000 300

disposicin

16+416
520+220
525
7

Los autores, 1998; Edicions UPC, 1998.

Asreal

dreal

2.211,7

946.5

2.199,1

926.4

2.454,4

952.5

326

Hormign armado y pretensado. Ejercicios

As =1.607,8 mm

Seccin apoyo

nf

16

20

25

(mm)

disposicin

16+216
620
425

Asreal(mm)

dreal(mm)

1.608,5

939.7

1.885

955

1.963,5

952.5

Esfuerzo cortante:
Vrd = Vd + Vcd = Vd

Vd = 257 kN

Vd

u1

Vu1

= Kf

b z

1cd

q + cot ga
1 + cot g q

cot g

q = 45
Cercos verticales

a = 90
2

f1cd = 0.6fcd = 0.620 N/mm = 12 N/mm


b0 = 300 mm
z = 0.9d = 0.9955 mm = 859.5 mm

s'
5
= 1 +
3
f
K =
s' = 0
A =

<1

0
K=
0

cd

cd

cd

s2

>1 K =1V

kN

Vcu = 257 kN < Vu1 = 1547.1 kN


Vd

u2

= Vcu + Vsu

Vcu = (0.1

200

x =1+
r =

x (100r f
=1+

As

ck

1/3

200
955

< 0.02 r =
l

b0d

=112N/mm 300mm859.5mm1/2=1547.1

u1

-0.15

cd

cumple

) b0d

= 1.4576
2

1.885 mm

= 0.0066 = 0.6575 10 - < 2 10 2

300 955 mm

fck = 30 N/mm

cd

= 0

b0 = 300 mm

b = f (q, q ) cot gq =
e

=1 q = q b =1

xd

f ct ,m

1/3

Vcu = 0.1 1.4576 (1000.006630)

300 9551 = 112.9756 kN

Vrd = Vcu + Vsu


Vsu = Vd - Vcu = (257-112.9756) kN = 144 kN
Vsu =

A a f a 0.9d sen a (cot ga + cot gq)


y d

Los autores, 1998; Edicions UPC, 1998.

Elementos Estructurales

327

Vsu

Aa =

f yad

0.9 d

144 10 N

348N / mm

0.9 955mm

= 0.4814 mm

/ mm

Verificacin armadura mnima:

0.20
+ 0.75 b = 135N / mm
sen a
20

A a f ya d

ck

A a f yad

= 167.5N / mm > 135N / mm cumple

sen

Armadura mxima:
A a f yad

sen

f1cd

b
0

12N / mm 300 mm = 1800 N / mm


- cos a 2
167.5N / mm < 1800 N / mm cumple
sen

Distribucin de la armadura transversal:


2

Aa = 0.4814 mm /mm = 4.814 mm /cm


St Aa

8
10
12

=n

Pf
r

S =n
t

Pf fmm

S = 0.3263f [fcm ]
4 A a A a mm / cm
2

St = 20.1 cm
St = 32 cm
St = 46 cm

1/5 Vu1 = 1/51.547,1 kN = 309.42 kN


Vd = 257 kN
2/3 Vu1 = 2/31.547,1 kN = 1031.4 kN
Vrd = 257 kN < 1/5 Vu1 = 309.42 kN

0.80d < 300 mm


S 0.80955mm = 764 mm < 300 mm
h
Pf
Aa =

St

St = 300 mm (mxima)

St

8 / 20 Aa =
10 / 30 Aa =

2
200

2
300

P8

= 0.5027 mm

P 10
4

/ mm

= 0.5236 mm

/ mm

Los autores, 1998; Edicions UPC, 1998.

328

Hormign armado y pretensado. Ejercicios

Los autores, 1998; Edicions UPC, 1998.

329

Elementos Estructurales

Ejercicio III-3 Dimensionamiento de un pescante


Considrese el pescante de hormign armado cuyas dimensiones se indican en la figura adjunta.
Dicha estructura se encuentra a la intemperie en un ambiente exterior normal.

La estructura est sometida a las siguientes acciones:


- peso propio: 8 kN/ml
- sobrecarga uniforme permanente en el dintel (AC) de 22 kN/ml
- sobrecarga de uso: carga puntual mvil de 100 kN que puede actuar nicamente en el
tramo BC del dintel
- viento: carga puntual horizontal de 50 kN
- nieve: sobrecarga uniforme de 10 kN/ml
Se consideran los siguientes materiales:
- hormign HA30/P/12/IIb
- acero B500 S

fck = 30 MPa

fyk = 500 MPa

Asimismo, se considera un nivel de control intenso.

Se pide:
1. Obtener las leyes de esfuerzos de clculo con los que se debe dimensionar la estructura frente a
estados lmite ltimos, utilizando el criterio simplificado de l7a instruccin EHE, y dimensionar la
estructura.

Los autores, 1998; Edicions UPC, 1998.

330

Hormign armado y pretensado. Ejercicios

Solucin
1.1 Solicitaciones de clculo
Las envolventes de momentos flectores, cortantes y axiles pueden encontrarse en el ejercicio I-2 de
esta coleccin.
1.2 Dimensionamiento a flexin
Una

vez

determinados

dimensionamiento

de

los
las

momentos
armaduras

flectores

que

longitudinales

actan

sobre

necesarias

la

por

estructura
flexin.

se

Se

pasa

al

comienza

determinando dichas armaduras para cada uno de los tres elementos del pescante (pilar, parte
derecha del dintel y parte izquierda del dintel) para posteriormente intentar compatibilizar del modo
ms racional las armaduras resultantes. En cualquiera de los tres casos la situacin es de
flexocompresin recta.
Por ser necesario para los clculos se explicitan los coeficientes de minoracin adpotados para las
resistencias de clculo del acero y el hormign
Acero
Hormign

g
g

= 1.15

= 1.5

Se pasa a desarrollar el dimensionamiento:


1.2.1 Pilar

- Momentos flectores positivos


La expresin analtica de las envolventes de los esfuerzos (flectores positivos y axiles) que actan
sobre el pilar es (tomando origen de X en la base del pilar):
Md = 810 67.5 X (kNm)
Md = 551.25 (kNm)
Nd = 448.2 10.8 X (kN)

0 X 3.83
3.83 X 4
0X4

La determinacin de la excentricidad (cociente entre el momento flector y el esfuerzo axil) ser


necesaria para conocer las secciones ms desfavorables desde el punto de vista del anlisis a flexin.
As se deber considerar, al menos, la seccin de mxima excentricidad (mximo flector respecto al
axil, que ser la seccin donde se den las mayores tracciones) y la de mnima excentricidad
(mximo axil en comparacin con el momento, que ser la seccin con mayores compresiones). La
expresin analtica de la excentricidad es:

e0

Md
Nd

Los autores, 1998; Edicions UPC, 1998.

331

Elementos Estructurales

- 67.5 X
448.2 - 10.8 X
810

X 3.83 e =
0

3.83

X4e =
0

551.25
448.2

- 10.8 X

La excentricidad mxima se da para X = 0 (seccin del empotramiento) y vale eo = 1.807 m; la


excentricidad mnima se da para X = 3.83 m y vale e0 = 1.355 m.
Se comienza analizando la seccin del empotramiento (Md = 810 kNm; Nd = 448.2 kN; e = 1.807
m). El primer paso es realizar una hiptesis sobre el canto til. Por tratarse de una estructura que va
a estar a la intemperie en ambiente normal y un hormign de resistencia caracterstica fck = 30 MPa
(25 < fck < 40 MPa) el recubrimiento mnimo de las armaduras debe ser r = 4 cm. En primera
aproximacin, suponiendo cercos de 10 mm y armadura longitudinal de 20 mm y en una sola fila, el
canto til vale:

= h -r-f

cer cos

- f
2

armlong

= 0.8 - 0.04 - 0.01 - 0.01 = 0.74 m

d1 = d2 = h d = 0.8 0.74 = 0.06 m

d2
r
d
r
d1

A continuacin podemos calcular las excentricidades del esfuerzo respecto de las armaduras
longitudinales As1 y As2:
e1 = e0 + d h/2 = 1.807 + 0.74 0.8/2 = 2.147 m
e2 = e0 h/2 + d2 =1.807 0.8/2 + 0.06 = 1.467 m
El momento lmite de la seccin vale:

y lim

= 0.8 x

lim

0.8 0.74

= 0.364 m
=
f
e
1+
1+
E 0.0035
e
0.8 d
y

yd

Los autores, 1998; Edicions UPC, 1998.

332

Hormign armado y pretensado. Ejercicios

f yd
Ey

M lim

500 / 1.15
200000

= 0.0022

= 0.85 f b y
cd

lim

y lim
2

= 1381.16 KNm

Puesto que Md = 810 kNm < Mlim, se plantea el siguiente equilibrio (sin armadura de compresin):
Nd

= 0.85 f b y - A f

Nd

e = 0.85 f b y d -
2

cd

s1

(1)

yd

(2)

cd

De (2), se tiene

0.9623 MNm

= 0.85 20 0.4 y 0.74 -


2

= 0.2256 m

y entrando en (1),
0.4482 MN

= 0.85 20 0.4 0.2256 - A f


s

yd

As

f = 1.0859 MN

As

yd

1.0859 10

434.8 N mm

= 24.98 cm

que se absorben con 8 20 6 25.


Los ocho redondos de 20 mm cumplen de modo estricto las limitaciones de separacin entre
armaduras y caben en una sola fila (se deja entre cada dos barras consecutivas un paso de 20 mm).
Sin embargo, parece ms adecuado optar por la solucin (desde la perspectiva de evitar una
excesiva

acumulacin

de

armaduras

permitir

un

tamao

mayor

de

rido

una

mejor

compactacin) de 6 25.
Una vez dimensionada la armadura se calcula el canto til real:
dreal = 0.8 0.04 0.01 0.0125 = 0.7375 < dhip = 0.74 m
Por tanto se retoma el dimensionamiento con un canto menor. En previsin de que esto pueda
aumentar las necesidades de armadura se prueba con un canto til menor al obtenido en la iteracin
anterior dhip = 0.73 m (d1 = d2 = 0.07 m). Tabulando los resultados obtenidos:
e1 (m)
2.137

e2 (m)
1.477

ylim (m)
0.359

Mlim (kNm)
1343.88

Nd*e1 (kNm)
957.80

y (m)
0.229

As1 (cm )
25.51

Luego se mantiene la misma cuanta de armadura que antes. El canto til real es:
dreal = 0.8 0.04 0.01 0.0125=0.7375 > dhip = 0.73 m
d1 = d2 = 0.0625m

Los autores, 1998; Edicions UPC, 1998.

Correcto

f 25 n
6

333

Elementos Estructurales

Para completar el dimensionamiento se deben considerar secciones adicionales en las cuales, por ser
menores los esfuerzos actuantes, es de preveer una menor necesidad de armadura longitudinal. Para
tener en consideracin el incremento de tensin que genera en la armadura longitudinal la presencia
de esfuerzos cortantes (interaccin flexincortante) se ha procedido a decalar la ley de momentos
flectores un canto til. Se analizan cuatro secciones, situadas respectivamente a 2, 3, 3.83 y 4 m del
empotramiento. Los resultados se recogen en la siguiente tabla:
Seccin

Md

Nd

e0

e1

e2

ylim

Nd*e1

(m)

(kNm)

(kN)

(m)

(m)

(m)

(m)

(kNm)

X=2

724.79

426.6

1.699

2.037

1.362

0.362

868.98
797.92

X=3

657.30

415.8

1.581

1.919

1.244

0.362

X=3.83

601.29

406.8

1.478

1.816

1.141

0.362

738.82

X=4

552.33

405

1.364

1.701

1.027

0.362

688.91

f25

Seccin

Mlim

As2

As1

(m)

(kNm)

(cm )

(m)

(cm )

X=2

1369.88

0.201

21.62

X=3

1369.88

0.181

18.75

X=3.83

1369.88

0.166

16.61

X=4

1369.88

0.153

14.61

Si ahora se tienen en consideracin las necesidades de anclaje, lo ms racional es mantener los 6 25


los 4 m de longitud del pilar o bien reducirlos a 5 redondos a partir de 2 m ms la longitud de
anclaje.
- Momentos flectores negativos
La expresin analtica de las envolventes de los esfuerzos (flectores negativos y axiles) que actan
sobre el pilar son:
Md = 232.5 75 X

0<X<3.1
0X4

(kNm)

Nd = 448.2 10.8 X

(kN)

En este caso se realiza el anlisis para la seccin del empotramiento (donde se dan los esfuerzos
mximos y para la seccin situada a una distancia de 1 m de dicho empotramiento. Las necesidades
de anclaje hacen preveer que no sea necesario realizar un anlisis en ms secciones. Se ha
considerado el decalaje de la ley de flectores en un canto til para tener en cuenta la interaccin
flectorcortante. Los resultados se tabulan a continuacin:
Seccin

Md

Nd

e0

e1

e2

ylim

Nd*e1

(m)

(kNm)

(kN)

(m)

(m)

(m)

(m)

(KNm)

X=0

232.5

448.2

0.519

0.857

0.175

0.362

384.11

X=1

212.81

437.4

0.487

0.825

0.150

0.362

360.86

Los autores, 1998; Edicions UPC, 1998.

334

Hormign armado y pretensado. Ejercicios

f25

Seccin

Mlim

As2

As1

(m)

(kNm)

(cm )

(m)

(cm )

X=0

1369.88

0.081

2.162

X=1

1369.88

0.076

1.875

Observamos que por razones resistentes slo es necesario 1 25. Sin embargo, se propone como

solucin ms adecuada el colocar al menos 2 25, lo que ms adelante se comprobar que adems es
necesario por condicionantes de armadura mnima a flexin.
1.2.2 Parte derecha del dintel

En este caso slo tenemos momentos flectores de un signo (traccin superior). La expresin
analtica de la envolvente de dichos momentos y de los esfuerzos axiles es (origen de X en el pilar):
2

Md = 27 X 297 X + 648 (kNm)


Nd = 75 (kN)

0<X<3
0<X<3

De nuevo es una situacin de flexocompresin recta. El anlisis a desarrollar es completamente


anlogo al realizado para el pilar. Para simplificar el posterior tratamiento en la colocacin de las
armaduras, se dimensionar la armadura a flexin con barras corrugadas de 25 mm de dimetro. De
esta forma, y en previsin de que las armaduras necesarias puedan disponerse en una nica fila, se
mantiene el canto til (0.7375 m). De nuevo se ha considerado el decalaje de la ley de momentos
flectores y se han analizado varias secciones para poner de manifiesto cmo van variando las
necesidades de armadura a flexin. Los resultados obtenidos son los que se recogen a continuacin:
Seccin

Md

Nd

e0

e1

e2

ylim

Nd*e1

(m)

(kNm)

(KN)

(m)

(m)

(m)

(m)

(kNm)

X=0

648

75

8.64

8.978

8.303

0.362

673.35

X=1

571.9

75

7.63

7.968

7.293

0.362

597.6

X=1.5

437.24

75

5.83

6.168

5.493

0.362

462.6

X=2

316.07

75

4.21

4.548

3.873

0.362

341.1

X=3

114.25

75

1.52

1.858

1.183

0.362

139.35

f25

Seccin

Mlim

As2

As1

(m)

(kNm)

(cm )

(m)

(cm )

X=0

1369.88

0.149

21.58

X=1

1369.88

0.131

18.76

X=1.5

1369.88

0.099

13.76

X=2

1369.88

0.072

9.54

X=3

1369.88

0.028

3.36

Debido a las necesidades de anclaje de la armadura, lo ms razonable parece mantener los 5 25


durante los 3 m del flanco derecho del dintel. A lo sumo se pondra plantear reducirlos a 4 a partir
de 1 m ms la longitud de anclaje.

Los autores, 1998; Edicions UPC, 1998.

335

Elementos Estructurales

1.2.3 Parte izquierda del dintel

En este caso slo hay momentos flectores de un signo (traccin superior). La expresin analtica de
la envolvente de dichos momentos y de los esfuerzos axiles es (tomando origen de X en el pilar):
2

Md = 27.75 X 111 X+111 (kNm)


Nd = 75 (kN)

0<X<2
0<X<2

De nuevo es una situacin de flexocompresin recta. El anlisis que se debe desarrollar es


completamente anlogo al realizado para el pilar. Para simplificar el posterior tratamiento en la
colocacin de las armaduras, se dimensiona la armadura a flexin con barras corrugadas de 25 mm
de dimetro. De esta forma, y en previsin de que las armaduras necesarias puedan disponerse en
una nica fila, se mantiene el canto til (0.7375m). De nuevo se ha considerado el decalaje de la ley
de momentos flectores y se han analizado varias secciones para poner de manifiesto cmo van
variando las necesidades de armadura a flexin. Los resultados obtenidos son los que se recogen a
continuacin:
Seccin

Md

Nd

e0

e1

e2

ylim

Nd*e1

(m)

(kNm)

(kN)

(m)

(m)

(m)

(m)

(kNm)

X=0

111

75

1.48

1.818

1.143

0.362

136.35

X=1

83.78

75

1.12

1.455

0.780

0.362

109.13

f25

Seccin

Mlim

As2

As1

(m)

(kNm)

(cm )

(m)

(cm )

X=0

1369.88

0.028

2.65

X=1

1369.88

0.021

1.56

Se observa que por razones resistentes slo es necesario 1 25. Sin embargo se propone como

solucin ms adecuada el colocar al menos 2 25, lo cual ms adelante se comprobar que adems es
necesario por condicionantes de armadura mnima a flexin.
1.2.4 Comprobacin de armadura m nima

La norma EHE fija que en todos aquellos casos en que el agotamiento de una seccin se produzca
por flexin simple o compuesta, bajo la accin de las cargas exteriores, la armadura resistente
longitudinal traccionada deber cumplir la siguiente limitacin:

As

0.04 A
c

f cd
f yd

(expresin para el caso de hormign armado y seccin rectangular).


Se sustituyen los valores que se presentan en la estructura:

Los autores, 1998; Edicions UPC, 1998.

336

Hormign armado y pretensado. Ejercicios

As

0.04 0.32

= 5.89 cm 2f25
500 10
20 10

1.15
Todas las propuestas de armado realizadas cumplen esta limitacin.
Por otra parte, y para los casos de flexin compuesta (como el presente), la norma EHE recomienda
disponer una armadura mnima de compresin que cumpla la condicin:

As

0.05 N d
f yd

Si se calcula ese valor para los esfuerzos axiles que actan sobre el pescante se obtiene:
Nd (kN)

As (cm )

448.2

0.52

405

0.47

75

0.086

Los valores obtenidos son mnimos y se consideran cubiertos con la armadura calculada. Dado el
canto de los elementos se dispondr una armadura de piel compuesta por dos barras

f12, una a cada

lado, a medio canto de pilar y mnsulas.


1.3 Dimensionamiento a esfuerzo s cortantes
En la estructura no se presenta seccin variable ni esfuerzos de pretensado, por lo que la
comprobacin relativa al E.L.U. de agotamiento por esfuerzo cortante se realiza directamente con el
cortante de clculo (pues el esfuerzo cortante reducido Vrd es igual al de clculo Vd). El agotamiento
por esfuerzo cortante puede darse por agotarse la resistencia a compresin del alma, o por agotarse
su resistencia a traccin. Por tanto las dos comprobaciones que se deben realizar son:
Vd
Vd

V
V

u1
u2

con:
Vu1, el esfuerzo cortante de agotamiento por compresin oblicua en el alma.
Vu2, el esfuerzo cortante de agotamiento por traccin en el alma.
La norma explicita que la primera comprobacin se realizar en el borde del apoyo, y no en su eje,
mientras que la segunda comprobacin debe realizarse para una seccin situada a una distancia de
un canto til del apoyo directo.

Los autores, 1998; Edicions UPC, 1998.

337

Elementos Estructurales

1.3.1 Comprobacin de agotamiento p or compresin

Los valores del esfuerzo cortante para los cuales debe efectuarse esta comprobacin son (se recoge
tambin el axil por ser necesario para determinar Vu1):
Vd (kN)

Nd (kN)

Pilar

75

448.2

Parte derecha del dintel

297

75

Parte izquierda del dintel

111

75

La expresin propuesta por la norma para el esfuerzo cortante por agotamiento por compresin
oblicua del alma, adoptando un ngulo

= 90 para las armaduras transversales y considerando

que las bielas de compresin forman un ngulo de

Vu1

= K f

1cd

b z

q = 45 (valor tpico en hormign armado) es:

q + cot g a
1 + cot g q

cot g

donde:
f1cd = 0.6fcd
b0 = b = 0.4 m
z

@ 0.9d

El valor de

q se suele considerar 45 en hormign armado, pero en este caso, la presencia de axiles


q en el supuesto de

de compresin puede modificar este valor. Se puede establecer el ngulo


comportamiento elstico y en el instante de fisuracin:

cot g

donde

xd

q=

xd

f ct ,m

se tomar como la tensin media que introduce el axil (traccin positiva) y fct,m es la

resistencia media a traccin del hormign

f ct ,m

= 0.3

f ck

= 0.3

(30 MPa )

= 2.896

MPa

De esta forma,
cotg

Pilar

1.22

39.34

Parte derecha del dintel

1.04

43.88

Parte izquierda del dintel

1.04

43.88

Los autores, 1998; Edicions UPC, 1998.

338

Hormign armado y pretensado. Ejercicios

Por lo tanto,

= 0.265 k f b d
Pilar

= Parte derecha dintel = 0.27 k f b d


Parte izquierda dintel = 0.27 k f b d

cd

Vu1

cd
cd

Para calcular el coeficiente K, se aplica

s
1 +
3
f
N + A
s =
K

cd

cd

cd

s2

sd,c

Ac

donde
Nd = esfuerzo axil de clculo (traccin positiva)
As2 = armadura de compresin

sd,c

se toma con valor 400 MPa

Por tanto el nico dato adicional que precisamos para calcular Vu1 es la cuanta de la armadura
longitudinal a compresin As2. En el caso del dintel sta es nula (lo determinamos en el
dimensionamiento a flexin). Para el pilar cabe la duda de qu armadura consideramos como a
compresin, pues dicha consideracin vara segn el momento flector que acte, sea positivo o
negativo. Para quedar del lado de la seguridad se toma la menor de las dos cuanta obtenidas en

flexin (2 25 frente a 6 25) pues esa armadura conduce a un valor de Vu1 inferior. En cualquier
caso, el valor de As2 slo influye en el coeficiente K de reduccin por esfuerzo axil y se puede
comprobar que con ambas armaduras la expresin proporciona un valor superior a la unidad por lo
que en ambos casos se adoptara K=1.
El resto de factores no ofrece mayor complejidad, por lo que se pasa a tabular los resultados de esta
comprobacin:

cd

(Pa)

Kcorregido

Vd

Vu1

(kN) (kN)
Pilar

2627810

1.45

75<1563.5, correcto

Parte derecha del dintel

1461560

1.55

297<1593, correcto

Parte izquierda del dintel

1461560

1.55

111<1593, correcto

1.3.2 Comprobacin del agotamiento por traccin en el alma

Se supone que la pieza va a estar dotada de armadura de cortante (posteriormente se comprobar si


la hiptesis realizada es cierta). De acuerdo con la norma se debe realizar la comprobacin en una
seccin situada a un canto til del apoyo (d=0.7375 m). Por tanto los esfuerzos que se deben
considerar para realizar esta comprobacin sern:

Los autores, 1998; Edicions UPC, 1998.

339

Elementos Estructurales

Vd (KN)

Nd (KN)

Pilar

75

440.24

Parte derecha del dintel

257.14

75

Parte izquierda del dintel

70.07

75

El esfuerzo cortante de agotamiento por traccin en el alma vale:


Vu 2

=V +V

Vcu

r =
l

cu

su

0.10

As

x (100 r f
l

cd

0.02

200

x =1+

) - 0.15 s ) b d b
1/ 3

ck

d ( mm )

cot g q - 1
0.5 cot g q cot g q
2 cot g q - 1
cot g q - 2
b=
cot g q cot g q 2
cot g q - 2
b=

donde

cot g

q=

Se adopta cotg

xd

f ct ,m

q = cotg q

, por lo que

b = 1.

Operando se tabula el resto de valores necesarios para el clculo de Vcu:


As
Pilar
Parte derecha del dintel
Parte izquierda del dintel

f
5f25
2f25

8 25

0.0133

1.521

2627810

0.0083

1.521

1461560

0.0033

1.521

1461560

cd

(Pa)

Con todos estos valores se calcula Vcu:


Vd (kN)

Vcu (kN)

Vsu = Vd Vcu (kN)

Pilar

75

269.6

Vcu > Vd

Parte derechadel dintel

257.14

195.7

61.44

Parte izquierda del dintel

70.07

161.02

Vcu > Vd

Se observa que tanto en el pilar como en la parte izquierda del soporte se hace innecesaria la
armadura transversal. Por tanto la hiptesis realizada al principio no es correcta para estos

Los autores, 1998; Edicions UPC, 1998.

340

Hormign armado y pretensado. Ejercicios

elementos y se debe aplicar la comprobacin que propone la EHE para el caso de piezas sin
armadura de cortante:

Vu 2

0.12

x (100 r f
l

) - 0.15 s ) b d
1/ 3

ck

cd

El resultado es superior a Vcu, luego en ambos casos se verifica Vd < Vu2 y la comprobacin es
correcta.
Y ahora ya podemos dimensionar la armadura transversal a cortante para la parte derecha del dintel.
Puesto que hemos supuesto

= 90 y

= 45 la expresin que nos permite efectuar dicho

dimensionamiento es:
Vsu

A 90

y 90,d

cotg q

donde
z = 0.9 d
fy90,d = 400 MPa
Vsu = Vd Vcu
Y para transformar dicha cuanta en armadura real se consideran cercos de dos ramas, con lo cual la
separacin entre stos ser:

St

pf
4 A

90

Se tabulan los resultados obtenidos:


2

Vsu (kN)

A90 (cm /m)

61.44

2.25

Parte derecha del dintel

St con

f8

(cm)

St con

44.7

1.3.3 Armadura mnima a cortante

La cuanta mnima de tales armaduras debe ser tal que se cumpla la relacin:

A 90

0.20
f y 90,d

+ 0.75 b = 4.5mm
20

ck

/m

f8 cada 22.3 cm f10 cada 34.91cm

1.3.4 Disposicin de la armadura tran sversal

La separacin entre los cercos deber verificar las siguientes condiciones:

Los autores, 1998; Edicions UPC, 1998.

f10 (cm)

69.8

341

Elementos Estructurales

St
St
St
St
St
St

0.8 d
300 mm

0.6 d
300 mm
0.3 d
200 mm

si

si

1
5

si Vrd

Vu1

Caso 1

Vu1

Vu1

<V

2
3

rd

2
3

Vu1

Caso 2

Caso 3

rd

1/5 Vu1

Vd (kN)

(kN)

Caso

Stmax

Pilar

75

312.7

300

Parte derecha del dintel

297

318.6

300

Parte izquierda del dintel

111

318.6

300

Por lo tanto, se colocarn cercos

f10 cada 30 cm en toda la estructura.

1.4 Comprobacin del estado lm ite de inestabilidad

Esbeltez mecnica

Como

I
A

l =
m

bh

12 bh

l0
i

2 4
0.231
h

= 34.63 < 35
0.8

3.464

= 0.231

< 35 no hace falta verificar el estado lmite de inestabilidad.

1.5 Armado final

2 25

2 12

6 25

5 25

f10 / 30 cm

2 12

2 25

f10 / 30 cm

Los autores, 1998; Edicions UPC, 1998.

343

Elementos Estructurales

Ejercicio III-4 Zapata y encepado para pescante


Se desea cimentar el pescante cuyas leyes de esfuerzos de clculo se han obtenido en el problema
I-2 y cuyas armaduras se han dimensionado en el problema III-3.
Para ello se supondrn dos posibles terrenos:
- suelo cohesivo con

sadm = 200 kN/m2, para el que se dimensionar una zapata,


2

- suelo cohesivo con una cohesin aparente sin drenaje cu = 57 kN/m , para el que se
dimensionar un encepado con dos pilotes. La adherencia pilote-terreno se estima en 32
2

kN/m .
En ambos casos se contar con los siguientes materiales:
- acero pasivo B500S, fyk = 500 MPa
- hormign HA-25/B/18/IIa, fck = 25 MPa
Solucin
El dimensionamiento de una cimentacin tiene siempre dos fases:
a) Determinacin de la geometra en planta. Esto se realiza teniendo en cuenta la capacidad portante
del terreno bajo cargas de servicio.
b) Dimensionamiento estructural del cimiento a partir de las acciones de clculo.
Para abordar la primera fase deben determinarse los esfuerzos de servicio a partir del problema
III-3. Realizando la combinacin con los correspondientes coeficientes de servicio se obtiene:
ESFUERZOS DE CLCULO

ESFUERZOS DE SERVICIO

M
810 mkN

232.5 mkN

550 mkN 125 mkN

N
448.2 kN

Los autores, 1998; Edicions UPC, 1998.

317 kN

344

Hormign armado y pretensado. Ejercicios

75 kN

75 kN

50 kN

50 kN

1 Solucin zapata
1.1 Determinacin de la cimenta cin a partir de la capacidad portante del terreno
Sobre el terreno (base de la zapata) actan:
a)

Tensiones normales causadas por:


i) Npilar + Wzapata
ii) Mpilar + Vpilarh

b)

Tensiones tangenciales causadas por:


i) Vpilar

Suponiendo una zapata cualquiera, la distribucin de tensiones en la base (aceptando que se


comporta como un slido rgido) ser:

b
a

Si e = M/N = (Mpilar + Vpilar h)/(Npilar + Wzapata) < a/6 (ncleo central), entonces trabaja toda
la zapata apareciendo las siguientes tensiones:

N
s max =
min

N
a' b'

6M
2

a' b'

smin

Los autores, 1998; Edicions UPC, 1998.

smax

345

Elementos Estructurales

Si e = M/N > a/6 , entonces parte de la zapata no trabaja y la tensin mxima resulta:

s max =

4N

3( a' 2 e )b'

c = a/2 e

smax
3c

Se plantea una zapata con las siguientes dimensiones:

b =
a = 0,8 m

0,4 m

h =

2 m

0,65 m

0,8 m

b = 2 m

a = 4,8 m

La zapata es de tipo flexible (v

2h)

pero se supone (art.59.3.1) que la cimentacin se comporta

como un slido rgido.


Debe comprobarse que el terreno soporta las acciones de servicio.
Se consideran dos hiptesis de carga:
HIPTESIS 1

HIPTESIS 2

317 kN + Wzapata

317 kN + Wzapata

125 kNm + 50kNh

547 kNm + 50kNh

50 kN

50 kN
que para los valores a = 4.8 m, b=2 m, h=0.65 m resultan:
HIPTESIS 1

HIPTESIS 2

473 kN

473 kN

580 kNm
50 kN

Los autores, 1998; Edicions UPC, 1998.

157.5 kNm

50 kN

346

Hormign armado y pretensado. Ejercicios

Hiptesis 1:
La excentricidad de las cargas normales es

580 kNm

473 kN

= 1.226 m

Puesto que el ncleo central de la zapata es

ec

4.8 m
6

= 0.8 m

el tipo de carga sobre el terreno ser triangular:

473 kN
580 kNm

50 kN

smax

3c

Se resuelve el problema equilibrando fuerza y momentos, con lo que

smax = 134.30 kN/m2

3c = 3.522 m
Puesto que

sadm = 200 kN/m2, se cumple que smax sadm.


2

Por otra parte, las tensiones tangenciales que se generan en la base de la zapata son de 7.1 kN/m ,
que el terreno resiste perfectamente.

t@

V
A

50

3.522 2

= 7.1 kN / m 2

Hiptesis 2:
La excentricidad de las cargas normales es:

M
N

157.5 kNm
473 kN

= 0.333 m

Los autores, 1998; Edicions UPC, 1998.

347

Elementos Estructurales

La carga equivalente queda, por tanto, dentro del ncleo central de la zapata y el tipo de carga sobre
el terreno ser trapezoidal. Resolviendo, se obtiene el siguiente esquema:

473 kN
157.5 kNm

50 kN

28.76 kN/m

69.78 kN/m

las

tensiones

tangenciales

sobre

el

terreno

son

de

5.21

kN/m ,

que

el

terreno

resiste

perfectamente.
1.2 Dimensionamiento de la zapa ta
Debe considerarse el valor mayorado de las acciones combinadas, incluidas las acciones del terreno,
utilizando los esfuerzos mayorados. Atendiendo al artculo 59.3 no se incluye aqu el peso propio de
la zapata.
La distribucin de presiones del terreno responder nuevamente a dos hiptesis de carga:
HIPTESIS 1

HIPTESIS 2

448.2 kN

448.2 kN

232.5 kNm + 75kNh

810 kNm + 75 kNh

75 kN

75 kN
que para h=0.65 m resulta:
HIPTESIS 1

HIPTESIS 2

448.2 kN

448.2 kN
858.75 kN

75 kN

que dan lugar a las distribuciones de tensiones siguientes:

Los autores, 1998; Edicions UPC, 1998.

281.25 kNm

75 kN

348

Hormign armado y pretensado. Ejercicios

HIPTESIS 1

HIPTESIS 2

smax =

10.07

308.7

kN/m

kN/m

1.452 m

83.31
kN/m

1.2.1 Dimensionamiento a flexin com o zapata flexible

Hiptesis 1
b =
a = 0.8 m

0.4 m

2 m

b = 2 m

a = 4.8 m

smax =
308.7
0.548 m

1.452 m

kN/m

Seccin de referencia S : hacia el interior del pilar, a una distancia 0.15a = 0.12 m
a) Momento de clculo en S : provocado por el terreno (lado derecho)
M = 12 308.7 mkN 1.452m 2m 23 1.452m + 0.548m + 0.12m =

= 448.2kN 1.636 m = 733.25 kNm

Los autores, 1998; Edicions UPC, 1998.

349

Elementos Estructurales

H25 f = 25 MPa f =
16.67 MPa
B500S f = 500 MPa f =
434.78 MPa
ck

0.59

733.25 kNm

cd

yk

2m

yd

b d 2

;
x = 1 + 1.36 d10 f = 1 + 1.36 100.59 m434.78 MPa = 0.364 m ;
y = 0.8 x = 0.2912 m ;
m
M = 0.85 16666.7 mkN 0.2966m 2 m 0.59 m - 0.2966
2 = 3666.6 kNm
M

lim

= 0,85 f y
cd

lim

lim

-3

lim

-3

yd

lim

lim

lim

Resulta M M , luego:
(1) 0 = 0.85 f y b - A f

( 2 ) M = 0.85 f b y d - y

2
lim

cd

cd

yd

De (2):
= 0.85 16666.7kN / m 2 m y (0.59 m - y 2 ) = 3711.9
y = 1.14m NO
- 733.25 + 16716.7 y - 141667 y = 0

y = 0.046 m
2

733.25 kNm

kNm

0.85 16666.67kN / m 0.046m 2m = 1303.3kN = A f


15f16

A = 2.997610 m = 29.976 cm
10f20
7f25

Armadura mnima:
.7kN m
0.04 A ff = 0.04 2 0.65 16666
434800kN m = 19.933 10 m ,

-3

cd

yd

-4

yd

que es superada por la de clculo.


Por otra parte (art.42.3.5) debe disponerse una armadura mnima de un 2.8 en la cara de
traccin:

Los autores, 1998; Edicions UPC, 1998.

350

Hormign armado y pretensado. Ejercicios

A
A

0.0028 A

smin

smin

> 36.4 10 -

(12f20)

b) Momento de clculo en S (lado izquierdo) a causa del peso de la zapata


1

0.12 m

1 + 0.12 m
W

S1

= 0.65m 2m 2m 25kN / m = 65 kN
M = 65kN 1.12m = 72.8 kNm
M = 1.35 72.8kNm = 98.28 kNm
2

M < M , luego:
98.28 kNm = 0.85 16666.7kN/m 2m y (0.59 - y / 2 )
- 98.28 + 16716.7 y - 14166 .695y = 0
y = 0.00591 m
0 = 0.85 16666.7 mkN 2m 0.00591m - A f A = 3.85 cm 2f20

A f = 167.45 kN

lim

yd

yd

Cuanta mnima:
0.04 A ff

cd

Si

a=

A f
A f
s

yd

cd

= 0.04 2 0.65

yd

16666.7kN m = 19.933 10 m
434800kN m
2

-4

3.85 10 434800 = 1.403


2 0.65 16666.7
-4

se tendr, dado que A < 1.993310 m , una armadura de aA = 1.4033.8510 m =


5.403210 m , que corresponde a 2 f20.
No obstante, debe colocarse una armadura mnima (art.42.3.5) de cuanta geomtrica 2.8 en la
cara de traccin, luego:
s

-4

-3

Los autores, 1998; Edicions UPC, 1998.

-4

351

Elementos Estructurales

A
A

smin

0.0028A

smin

> 36.4 10 -

(12f20)

Hiptesis 2
El momento de clculo en S (lado izquierdo) vale:
1

0.12 m
2.12 m

S1

10.07
83.31
kN/m

kN/m

50.962

kN/m

M = 50.962 mkN 2.12m 2m 2.122 m + (83.31 - 50.962 ) mkN 12 212m 2m 23 2.12m =

= 229.04kNm + 96.92kNm = 325.96 kNm


Puesto que el momento de clculo es menor que en la hipotesis 1, se adopta la misma armadura
superior e inferior (12 f20).
La disposicin de la armadura ser:
d

15 cm aprox.

12

59

cm

12

6 cm

f 20 As2
f20
f 20 As1

5 cm
190 cm

Puesto que la distancia entre A y A es superior a 30 cm se colocar a medio canto una armadura
longitudinal a cada lado (A : 2f20). De esta forma se cumple la limitacin
s1

s2

s3

Los autores, 1998; Edicions UPC, 1998.

352

Hormign armado y pretensado. Ejercicios

r=

A +A +A
A
s1

s2

s3

26 p = 6.28 10
200 65

> 1.4 10 -

-3

En la otra direccin se adopta la misma limitacin:


2 A + 2f12 = 1.4 10 A = A = 20.71cm
480 65cm
-3

s1

s1

s2

y se colocar por tanto 1f12 cada 15 cm en ambas caras y 1f12 a medio canto.
1.2.2 Dimensionamiento a cortante co m o elemento lineal

Se calcula exclusivamente a cortante:


V = 12 308.7 mkN 2m 1.452m = 448.23 kN
Comprobacin bielas comprimidas:
ga
V V = k f b z cot1 +gqcot+ cot
gq
donde f = 0.6f = 0.6 16.67 MPa = 10 MPa
b =2m
z = 0.9 d = 0.9 0.59 m = 0.531 m
rd

rd

u1

1cd

1cd

cd

k = 53 1 + sf 1

N + A s = 12 314mm (- 434.8MPa ) = -1.26 MPa


s =
A
2000 650mm
5
1
.
26
k = 3 1 - 16.67 = 1.54 > 1 k = 1

cotg q = cotg 45 = 1
cotg a = cotg 90 = 0
N
1
V = 1 10
mm 2000mm 531mm 2 = 5310kN > V
Para dimensionar las armaduras, se comprueba previamente si son precisas:

=(
x( r ) s ) (sin armadura de cortante)
donde x = 1 + 200
d , d en milmetros x = 1.582
cd

cd

s2

sd ,c

cd

u1

Vrd

rd

Vu 2

0.12

100

f ck

1 3

0.15

cd

b0

Los autores, 1998; Edicions UPC, 1998.

353

Elementos Estructurales

b =2m
d = 0.59 m
A p 12 10 m
r =
b d = 2m 0.59m = 3.195 10
f = 25 MPa
Despreciando el efecto favorable de las compresiones, dado que A es armadura mnima,
V = 0.38 MPa 2000 mm 590 mm = 448.4 kN V , luego no es necesaria armadura a
cortante.
0

-4

-3

ck

s2

u2

rd

2 Solucin encepado y dos pilo tes


2.1 Determinacin de la cimenta cin a partir de la capacidad portante del terreno

El encepado se plantea porque el terreno se supone en este caso de tipo cohesivo con reistencia muy
baja, en concreto:
C = cohesin aparente sin drenaje = 57 kN/m .
En este caso la zapata resultante sera muy grande y se prefiere recurrir a una solucin de encepado
y dos pilotes.
El dimensionamiento se realiza evitando que los pilotes entren en traccin bajo cargas de servicio.
Se plantea un encepado como el de la figura:
2

c
a
c

b
b

2r

La distancia c se toma como el mnimo posible segn norma, a saber, 0.25 m.


Sobre el encepado actan tres esfuerzos:

Los autores, 1998; Edicions UPC, 1998.

354

Hormign armado y pretensado. Ejercicios

Ns
Ms
Vs

Para determinar la carga sobre los pilotes en condiciones de servicio se trasladan las cargas a la base
del encepado, en la hiptesis de un comportamiento de la cimentacin de slido rgido. Los
esfuerzos trasladados son M , N y V :
M = M +V h
N =N +W
V =V
donde W = a b h 25 mkN
e

encepado

encepado

La carga sobre cada pilote de rea A ser


P = Nn M
Sx
despreciando la inercia de la seccin de cada pilote, lo que para n=2 (nmero de pilotes) resulta:
P = N2 M2x
Para r = 0.3 m; x = 2.05 m; h = 1.1 m se tiene:
e

mx
mn

mx
mn

317 kN

317 kN

125 kNm

547.5 kNm

50 kN

50 kN
90.2 kN

384.1 kN

281.1 kN

193.25 kN

La longitud del pilote se determina a partir de las condiciones del terreno y de las cargas de
servicio; la carga de hundimiento viene dada por la suma de la resistencia de punta y la resistencia
de fuste.

Los autores, 1998; Edicions UPC, 1998.

355

Elementos Estructurales

Q =Q +Q
Q = c N A , donde
c = cohesin aparente sin drenaje = 57 kN/m
N = coeficiente de capacidad portante = 9
A = rea del pilote = p 0.3 = 0.283 m
Q = c A , donde
c = adherencia pilote-terreno = 32 kN/m
A = rea lateral del fuste = L 2pr =1.885L
En este caso Q = 145.18 kN, luego Q debe ser, en el peor caso, de 238.92 kN, lo que conduce a
una longitud L=4 m.
Por otra parte, la existencia de V implica una carga horizontal de 0.5V sobre cada pilote. La carga
mxima horizontal que resiste el terreno en el caso de suelos cohesivos vale (Broms, 1964):
H = 9 c 2 r (L 1.5 2 r) = 954.2 kN
valor claramente superior al que introducen las cargas (factor 38.2 > 2.5).
h

2.2 Dimensionamiento de pilote y encepado

Finalmente, la cimentacin tiene la siguiente geometra:


b=
a = 0.8 m

0.4 m

h=
1.1 m

b = 1.1 m
a = 5.2 m
2.05 m

0.60 m

El encepado es rgido ya que el vuelo v = 1.65 m y v 1.5 h. Las cargas a considerar son las de
clculo, sin incluir el peso del encepado.

Los autores, 1998; Edicions UPC, 1998.

356

Hormign armado y pretensado. Ejercicios

Nd

448.2 kN
Md

810 kNm

Vd =
6.4 kN

Nd

448.2 kN
Md

232.5
Vd =

75 kN

441.8 kN

300.9 kN

kNm
75 kN

147.3 kN

Son dos los elementos que se deben dimensionar: el encepado y los pilotes.
Previamente debe hacerse notar que la existencia de V introduce una flexin y un cortante sobre los
pilotes. Si se acepta que el pilote es corto, se comportar rgidamente, desplazndose lateralmente.
Segn Broms (1964), se tendr:
M = 1/2 V (0.5 L + 0.75 2 r) = 1/2 75 kN (0.5 4 m + 0.75 2 0.3 m) =
91.9 kNm
d

Vd

2.2.1 Pilotes

Se dimensiona un elemento vertical de seccin circular sometido a N =441.8 kN y M = 91.9 kNm.


Si suponemos un control de ejecucin intenso, la excentricidad mnima es de 5 cm, lo que
proporciona un momento de 22.09 kNm, inferior al provocado por la carga horizontal. Por ello se
dimensiona con M = 91.9 kNm.
El dimetro de clculo ser:
(2r) = (2r) 0.95 = 0.57 m, que en efecto cumple
(2r) (2r) - 20 mm
(2r) (2r) - 50 mm
La armadura longitudinal a disponer resulta ser la armadura mnima:
d

cal

nom

cal

nom

cal

nom

f20

0.60 m

La armadura transversal consistir en cercos f8 cada 30 cm, que cumplen


f = 8 mm 0.25 20 mm = 0.25 f
s = 300 mm 15 20 mm = 15 f
t

mx

min

Los autores, 1998; Edicions UPC, 1998.

357

Elementos Estructurales

2.2.2 Encepado

Se dimensiona de acuerdo con el siguiente modelo de bielas y tirantes:


a = 0.8 m
0.25a = 0.2 m

v = 1.65 m

(d = 1 m)

C
0.85d

Td

De acuerdo con el modelo, tenemos:


T = N (v0.+850.25d a )
N = 441.8kN0(.185.65 1mm+ 0.2m ) = 961.6 kN = c arg a del pilote ms c arg ado
d

La compresin C ser:
T

T = C cos q C = cos
961.6kN = 1057.9 kN

q
C=
0.909
tg q = v +0.085.25 d a q = 24.7
El rea de la biela en la zona superior es
A = 0.4 0.4 cos q = 0.1453 m
y en la zona inferior
A = p r cos q = p (0.3) cos q = 0.256 m
Luego la tensin de compresin vale
1057.9kN = 7280.8 kN = 7.28 N
s =
0.1453m
m
mm
d

bs

bi

cb

y debe ser s 0.85 f = 0.85 16.67 MPa = 14.17 MPa.


El anlisis del nudo es el relativo a nudos con tirantes anclados (art. 40.4.3):
cb

cd

Los autores, 1998; Edicions UPC, 1998.

358

Hormign armado y pretensado. Ejercicios

N < f = 0.7 f = 11.67 MPa


mm
Por lo tanto slo falta dimensionar la armadura correspondiente al tirante:
N = 22.11cm 8f20
A f = T = 961.6kN A = 434961600
.8 N mm
Armadura secundaria:
La desviacin de los pilotes en el plano transversal provoca la aparicin de un segundo mecanismo
biela-tirante con tracciones superiores. Un modelo simplificado es el siguiente:
- se supone una desviacin del 10% de 2r= 0.1 0.6 m = 0.06 m;
- se plantea el modelo de la figura
s

cn

= 7.28

2 cd

cd

yd

(d = 1 m)
T3d

C3

0.85d

441.8 kN

l cos q = x tg q = 0.4146 q = 22.52


l sen q = 0.85 d
C = 441sen.8qkN = 1153.51 kN T = C cos q = 1065.6 kN
b
b

3d

T supone un rea de 24.51 cm 8 f20


Ante esta armadura debe disponerse una armadura vertical formando cercos que aten la armadura
longitudinal de las caras superior e inferior. Atendiendo al artculo 59.4.1.2.1.2, la armadura
vertical se dimensionar para resistir la siguiente traccin:
T = 2 (M + 0.4 b N ), donde
b = ancho transversal del pilar
M = momento transversal de clculo en el arranque del pilar
N = axil de clculo en el arranque del pilar.
M = 448.2 kN 0.1 0.6 m = 26.892 kNm
N = 448.2 kN
T =197.21 kN
b = 0.4 m
2

3d

d4

d4

Los autores, 1998; Edicions UPC, 1998.

359

Elementos Estructurales

Luego la armadura vertical ser de 4.54 cm . Se colocarn cercos f12 cada 30 cm rodeando ambas
armaduras.
La armadura longitudinal debe suplementarse con armadura en las caras laterales. Se colocarn
barras f20.
2

Asup

0.3 m

0.3 m

0.3 m

Armadura vertical de atado


f20

f20
Ainf

Los autores, 1998; Edicions UPC, 1998.

361

Elementos Estructurales

Ejercicio III-5 Viga de puente pretensado para trabajar junto a losa de compresin

Se desea proyectar una viga en doble T de hormign pretensado con armaduras pretesas, para ser
prefabricada y formar parte de un puente isosttico de 20 m de luz junto a una losa superior de
hormign armado construida in situ, de 20 cm tal como indica la figura adjunta.

- peso propio de la viga y de la losa (r =25 kN/m ),


- cargas muertas debidas a pavimento, aceras, barandillas e instalaciones g=3.0 kN/m ,
- sobrecarga uniformemente repartida de trfico q= 4.0 kN/m ,
- vehculo pesado representado por una carga puntual de 600 kN.
A efectos de clculo de esfuerzos longitudinales sobre las vigas se supondr que bajo las acciones
repartidas, cada viga recibe la carga tributaria correspondiente al intereje de 2.20 m y que bajo la
accin del vehculo pesado la viga ms solicitada recibe el 40% del momento y del cortante que
producira dicho vehculo actuando sobre la viga aislada.
h

Solucin

1 Caractersticas de los materiales

Hormign. En la viga, por ser pretensada y prefabricada se utilizar hormign de 50 MPa de


resistencia caracterstica, consistencia plstica (5 cm de cono de Abrams), tamao mximo 18 mm y
clase de exposicin IIa (ambiente normal de humedad alta). HP-50/P/18/IIa.
En la losa por ser de hormign armado se necesitar menos resistencia (30 MPa), el tamao mximo
ser algo mayor (20 mm) y para facilitar la puesta en obra se pedir un mayor asiento en el cono de
Abrams (8 cm, consistencia blanda), con la misma clase de exposicin, HA-30/B/20/IIa.
Armaduras pasivas. Se utilizarn redondos de acero corrugado soldable, de 500 MPa de lmite
elstico B500S. Los dimetros ms adecuados sern:
- Armadura de piel en vigas: f6.
- Armadura de flexin en vigas, si es necesaria: f16 y f20.

Los autores, 1998; Edicions UPC, 1998.

362

Hormign armado y pretensado. Ejercicios

- Armadura transversal (cortante y rasante) en vigas: f8,f10 y f12.


- Armaduras longitudinales y transversales en losa: f12, f16 y f20.
Armaduras activas pretesas. Cordones de 7 alambres de 1860 MPa de carga unitaria Y1860 S7 de
f0.6 (As = 140 mm ) y de f0.5 (As = 98.7 mm ).
2

2 Otros valores adoptados en el proyecto

- coeficiente final de fluencia del hormign: j = 2.5


- retraccin final del hormign: 4.10
- relajacin final del acero de pretensado: 6%
Por tanteos iniciales se adoptan tambin unos valores aproximados de prdidas instantneas y
diferenciales, en porcentaje sobre la fuerza de anclaje P , que son las siguientes:
Prdidas instantneas DP = 0.05 P
Prdidas diferidas DP = 0.15 P
Prdidas totales DP = 0.20 P
-4

anc

ins

anc

dif

anc

tot

anc

3 Coeficientes de seguridad

Para estados lmites de servicio se adoptan valores g =1 para las cargas y valores de g =0.9 o
g =1.1 para las acciones debidas al pretensado, segn las tensiones debidas al pretensado sean
favorables o desfavorables, respectivamente.
f

4 Clculo de esfuerzos

Las nicas cargas que se desconocen para poder calcular los esfuerzos son las del peso propio de las
vigas, para lo cual hay que predimensionarlas.
Ello puede hacerse una vez conocidos los dems esfuerzos, ya que el peso es una porcin muy
reducida de las carga. En principio podra estimarse el peso propio de una viga en un valor, por
ejemplo, similar al de la losa superior entre vigas.
Esfuerzos debidos al peso de la losa:
g = 25 2.2 0.2 = 11 kN / ml
M = g 8 l = 11 820 = 550 kNm
V = g 2 l = 11 2 20 = 110 kN
Esfuerzos debidos a las cargas muertas:
L

max,L

max,L

Los autores, 1998; Edicions UPC, 1998.

363

Elementos Estructurales

g = 2.2 3.0 = 6.6 kN / ml


M = g 8 l = 6.6 8 20 = 330 kNm
V = g 2 l = 6.62 20 = 66 kN
m

max,m

max,m

Esfuerzos debidos a la sobrecarga repartida:


q = 4 2.2 = 8.8 kN / ml
M = q 8l = 8.8 8 20 = 440 kNm
V = q2 l = 8.82 20 = 88 kN
Esfuerzos debidos al vehculo pesado:
20
M = 0.4 Q4 l = 0.4 600
= 1200 kNm
4
V = 0.4 Q = 0.4 600 = 240 kN
Sobre la viga actan, aparte de su peso propio, las cargas de la losa. Sobre el conjunto viga-losa
actan el resto de las cargas, que producen los siguientes esfuerzos:
DM = M + M + M = 330 + 440 + 1200 = 1970 kNm
DV = V + V + V = 66 + 88 + 240 = 394 kN
En estado lmite ltimo los esfuerzos que se deben considerar son:
M = 1.35 (M + M + M ) + 1.5 (M + M )
V = 1.35 (V + V + V ) + 1.5 (V + V )
2

max,q

max,q

5 Espesor de las almas: se adoptarn los siguientes criterios

- Espesor mnimo por razones constructivas:


La distancia libre entre caras internas de estribo deber ser superior al triple del tamao mximo del
rido, para facilitar la entrada del hormign.
e 2r + 2f + 3t
r = recubrimiento armadura transversal 20 mm
f = dimetro armadura transversal 12 mm
t = tamao mximo del rido 18 mm
e 2 20 + 2 12 + 3 18 = 118 mm
t

Los autores, 1998; Edicions UPC, 1998.

364

Hormign armado y pretensado. Ejercicios

- Resistencia al agotamiento del alma por compresin oblicua en el hormign. Segn EHE-98
(artculo 44):
ga V
V = k 0.6 f b z cot1 g+qcot+ cot
gq
k = 53 1 + sf >/ 1.0

+ A s
N
s =
A
u1

cd

'

cd

cd

'

s2

sd ,c

cd

donde:
= tensin axil efectiva en la seccin
N = esfuerzo axil incluyendo el pretensado
A = rea de la armadura de compresin
s = resistencia de clculo del acero comprimido
Para el clculo de k, a priori no se reconsiderar la existencia de armadura de compresin (A = 0)
y se adoptar un valor conservador para s = 12.5 N/mm (que es un valor alto como tensin
media del pretensado).
Con ello se tiene:
s

cd
d

s2

sd,c

sd

cd

k = 53 1 - sf

'
cd

cd

5 1 - 12.5 = 1.041 > 1 k = 1


3 33.3

El cortante de clculo es aproximadamente:


V = 1.35 V + 1.5 V = 1.35 286 + 1.5 328 = 878 kN
d

dg

dq

El brazo mecnico en rotura se considera z @ 0.9d, con d como canto til. En este caso adoptaremos
d @ 1.10 m y z @ 0.9 1.1=1.0 m. A priori supondremos cotgq=2 que es conservador a efectos de
compresiones en el alma.
Con todo ello podemos despejar b de las ecuaciones, con lo que se obtiene:
g q = 878 10 (1 + 4) = 110 mm
b = k 0.6V f z cot1 +gqcot+ cot
ga 1 0.6 33.3 1000 2
o

cd

Por tanto adoptamos b = 12 cm, que satisface los criterios resistentes y constructivos.
o

Los autores, 1998; Edicions UPC, 1998.

365

Elementos Estructurales

5.1 Cabezas superior e inferior

Las cabezas superior e inferior las predimensionamos de forma que la inercia proporcionada por
ellas y el alma sea suficiente para que las tensiones en vaco y en servicio sean las adecuadas.
Limitndonos en principio a cabezas rectangulares, hay diversas opciones en cuanto a su ancho y su
canto. La cabeza superior conviene que sea ancha para reducir la luz libre de la losa en el sentido
transversal. La cabeza inferior conviene que no sea muy ancha para facilitar su hormigonado.
El rea de la cabeza superior puede ser algo menor que la inferior, ya que en servicio se dispone de
la losa superior para albergar las compresiones debidas a las cargas muertas y sobrecargas, mientras
que en vaco la nica cabeza es la inferior de la viga. As pues, estableceremos a priori los siguientes
criterios:
A @ 0.75 A
b @ 1.50 b
sup

inf

sup

inf

Adoptaremos en principio b = 0.80 m, esto implicara:


b @ 1b.50 = 0.55 m
h = Ab = 0A.55 = 0.75A 0.55 = 0h.75 b0.55 = h 0.751.50 0.550.55
h = 1.95 h @ 2 h
sup

sup

inf

inf

inf

sup

sup

sup

sup

inf

inf

inf

sup

sup

Los autores, 1998; Edicions UPC, 1998.

366

Hormign armado y pretensado. Ejercicios

Con este criterio pueden expresarse todas las caractersticas mecnicas (rea, inercia, centro de
gravedad, etc.), en funcin nicamente de la variable h .
Para obtener h se establecern los criterios tensionales en las fibras superior e inferior de la viga
en vaco y servicio respectivamente, esto es s f (al transferir) y s f (a largo plazo).
Las ecuaciones que proporcionan las tensiones en servicio y vaco son:
P - P e - M v f
s
=A I
I
1 e v (M + M ) v
1 e v DM v
s
= -P
+
- DP
A I
I
A + I - I f
sup

sup

c,sup

ct

c,inf

ct

c,sup

ct

c,inf

ct

cdg final
v

u
M

cdg viga

l
t

v'
e

v'

vaco

donde:
A , I son el rea e inercia de la viga,
A , I son el rea e inercia de la viga ms losa,
M , M son los momentos debido al peso de la viga y de la losa, respectivamente,
DM es el momento debido a todas las cargas que actan sobre el conjunto viga y losa
(cargas muertas y sobrecargas),
DP es la prdida diferida de fuerza de pretensado.
Conocido h , las nicas incgnitas de las ecuaciones anteriores son P y e, ya que se adopta DP=0.15
P =0.15/0.8 P = 0.1875 P. A priori se adopta como criterio que la resultante del pretensado est
en el centro de la cabeza inferior, siendo siempre el recubrimiento mecnico de 10 cm. La primera
ecuacin proporcionar el valor mximo de la fuerza de pretensado (P ) y la segunda el mnimo
(P ) debe satisfacerse que P - P 0.15 P .
Si no se cumple, la seccin es insuficiente, y si el intervalo es excesivo se ha sobredimensionado la
seccin.
v

ancl

mx

mn

mx

mn

ancl

Los autores, 1998; Edicions UPC, 1998.

367

Elementos Estructurales

En la tabla adjunta se indican los valores obtenidos con variaciones de la altura h desde 0.05 hasta
0.1 m.
h (m)
0.05
0.06
0.07
0.08
0.09
0.10
rea viga (m )
0.197
0.212
0.228
0.243
0.259
0.274
Iner. viga (m )
0.026
0.029
0.031
0.034
0.036
0.038
V viga (m)
0.516
0.517
0.516
0.516
0.515
0.514
V viga (m)
-0.484 -0.483 -0.484 -0.484 -0.485 -0.486
e viga (m)
-0.384 -0.383 -0.384 -0.384 -0.385 -0.386
Mom. viga (kNm) 246.25 265.5 284.75 304.00 323.25 342.50
rea total (m )
0.538
0.553
0.569
0.584
0.599
0.615
Iner. total (m )
0.075
0.080
0.085
0.089
0.093
0.096
V total (m)
0.320
0.331
0.342
0.351
0.360
0.369
V total (m)
-0.88 -0.869 -0.858 -0.849 -0.84 -0.831
e total (m)
-0.78 -0.769 -0.758 -0.749 -0.740 -0.731
P mx (kN)
3137 3565.58 3939.23 4249.82 4496.23 4682.48
P mn (kN)
3474.73 3501.98 3527.55 3552.74 3578.29 3604.58
P ancl (kN)
4343.41 4377.48 4409.44 4440.93 4472.86 4505.73
DP/P ancl
-0.078 0.015
0.093
0.157
0.205
0.239
Se observa que se satisface el criterio DP/P 0.15 para un espesor h =0.08 m; sin embargo,
adoptaremos h =0.09 m para disponer de mayor margen frente a variaciones de las prdidas
respecto de lo previsto.
Por razones constructivas conviene hacer ligeras modificaciones en la forma de seccin, como indica
la figura adjunta.
s

2
4

sup
inf

pre

2
4

sup
inf

pre

ancl

A
L

K
I J
H

B
C

D
E F
G

Los criterios seguidos son:


- que el hormign pueda entrar sin dificultad en la cabeza inferior,
- evitar ngulos rectos o agudos y matar los cantos,
- facilitar la cada del hormign desde la cabeza superior hacia las almas (efecto embudo).

Los autores, 1998; Edicions UPC, 1998.

368

Hormign armado y pretensado. Ejercicios

Todo ello aconseja inclinar los paramentos CD, EF, IJ y LK, as como achaflanar los vrtices D, E,
G, H, J y K.
Las caractersticas de la nueva seccin con relacin a la inicial son:
Inercia = 0.0359
rea = 0.261 m
v = - 0.4913 m
v = 0.5087 m
c = 0.27 m
h = 0.5502 (rendimiento)
c = 0.28 m
Considerando la losa de 2.20 m de anchura (todo el ancho eficaz), y un coeficiente de equivalencia
entre hormigones n = ff = 0.6 = 0.775 , las caractersticas mecnicas de la seccin compuesta
son:
rea = 0.601 m
Inercia = 0.0917
v = - 0.8366 m
v = 0.364 m
c = - 0.4189 m
h = 0.5013
c = 0.1826 m
2

sup

inf

sup

inf

cl

cv

sup

inf

sup

inf

6 Obtencin de la fuerza de pretensado y disposicin de los cordones


6.1 Peso propio de la viga

Siendo el rea de la viga A = 0.261 m , el peso propio es g = 6.5525 kN/ml, los esfuerzos
mximos que genera son M = 326 kN.m, V = 65.3 kN.
2

6.2 Excentricidad del pretensado

De acuerdo con la tabla anterior, se estima una fuerza total en anclajes de 4472.9 KN para una
excentricidad e = - 0.385 m.
Veamos la disposicin real de cordones. La distancia entre ejes de cordones y desde el centro de
gravedad de los cordones al paramento debe ser igual o superior a 4 cm, de forma que se satisfagan
las condiciones establecidas en la instruccin con ello. En la cabeza inferior caben:
(n+1)4 = 55 n = 12.75 12 cordones 0.6
Colocaremos 11 cordones por fila. Si no hubiese armadura superior se necesitaran 22 cordones
0.6, dispuestos en dos filas a 4 y 9 cm de la fibra inferior, es decir, con una excentricidad e =
0.4263 m.

Los autores, 1998; Edicions UPC, 1998.

369

Elementos Estructurales

Esta excentricidad excedera la supuesta y adems generara fisuracin superior en zonas prximas a
los apoyos. Por ello se disponen tambin cordones a lo largo de toda la pieza, en la cabeza superior,
a 4 cm del paramento, de forma que la excentricidad en centro de vano sea igual o algo menor que la
terica (e 0.385 m).

0.385

-4472.9 0.4363 + P
P = 216.39KN

sup

0.4687 = ( 4472.9 + P

sup

) (-0.385)

sup

Se dispondrn dos cordones de 0.5, P = 274 kN, con lo cual la excentricidad real ser en centro
de luz e = - 0.375 m.
Para acomodar la ley de momentos de pretensado a la ley de momentos exteriores, dado que los
cordones son rectos, se procede a un entubado de parte de los mismos, de forma que la fuerza de
pretensado se introduzca no en los extremos de la viga sino donde acabe el entubado.
Se dividir la semiviga en tres zonas, de longitudes 4 m, 3 m y 3 m, desde los apoyos hasta centro
de luz, segn indica la figura.

Los autores, 1998; Edicions UPC, 1998.

370

Hormign armado y pretensado. Ejercicios

En la seccin de apoyos, mediante un simple clculo de equilibrio, se puede obtener el nmero de


tendones que se anclan (y por tanto no se entubarn) para que la fuerza resultante caiga en el ncleo
central. El resultado es que se anclan solo la capa superior.

En al zona intermedia, el nmero de cordones inferiores estar entre 7 y 22. Se puede obtener el
nmero necesario proporcionalmente al momento, MP = cte , por lo tanto, para x=4 m, P = 0.6 P es
decir 14 0.6.
Sobre la base de lo anterior, se propone la siguiente disposicin terica de cordones, que deber
modificarse en funcin de las longitudes de anclaje.
x

10

Con estos valores se procede a verificar las tensiones normales en las secciones extremas de cada
zona, que son las S1, S2, S3, S4, S5 y S6. Para ello debern tenerse en cuenta las cargas que actan
sobre la viga (pretensado, peso propio de viga y losa) y sobre la viga ms losa (cargas muertas,
sobrecargas y prdidas de pretensado). Las prdidas instantneas se calculan considerando el
acortamiento elstico y las diferidas se calculan slo sobre la viga, esto es, ignorando los efectos de
la losa, aunque no su peso.

Los autores, 1998; Edicions UPC, 1998.

371

Elementos Estructurales

Ejercicio III-6 Tirante de hormign pretensado

En la estructura de arco-tirante de la figura adjunta, el tirante est sometido a unos esfuerzos axiles
caractersticos de traccin de:
- 250 kN correspondientes a las cargas permanentes
- 175 kN correspondientes a las cargas variables

Las caractersticas de los materiales utilizados son:


- hormign: HP-40/12/P/IIa E =32.5 kN/mm
- armadura activa: - cordones formados por 7 alambres de 13 mm dimetro nominal (0.5),
Euronorma 138-79 (equivalente BS 5896:1980) (A cordon: 100 mm )
- E =195 kN/mm
- mnima carga rotura: 186 kN
- lmite elstico caracterstico 158 kN
n = EE = 6
2

Se pide:

Dimensionar el tirante en forma y dimensiones, definiendo la seccin geomtrica del mismo y la


armadura activa que se requiera.
Solucin

Para la determinacin de la armadura activa y de la seccin de hormign se requiere el


cumplimiento de diversos requisitos, los cuales se exponen a continuacin.
Este ejemplo est inspirado en el ejemplo del apartado 4, captulo 12 del libro de A. Naaman.
Ed. Mc Grawn Hill, 1982.

Prestressed Concrete and Design.

Los autores, 1998; Edicions UPC, 1998.

372

Hormign armado y pretensado. Ejercicios

1 Limitacin de las tensiones de compresin en el hormign

Para ello se debe limitar que la tensin en la seccin de hormign, en los instantes ms crticos
(inicial y final), sea inferior a la respuesta del hormign en el instante estudiado. Ello da lugar a las
siguientes ecuaciones:
s s
Instante inicial (t = 0):
[1]
s s
Instante final (t = ):
[2]
Ap

po

Ap

pt

An

ci

An

ct

donde A , rea neta de hormign (para el caso de armaduras pretesas o postesas adherentes), se
determina a travs de la expresin:
A = A -A
[3]
n

ps

siendo: A el rea transversal de la seccin del tirante,


A el rea de la armadura activa.
Sustituyendo el valor de A , dado en la ecuacin [3], en las expresiones [1] y [2] se obtiene una
nueva formulacin de las mismas.
[4]
A 1 + sA s
[5]
A 1 + sA s
g

ps

ps

po

ci

ps

pt

ct

1.1 Armadura activa

El valor de la tensin mxima de la armadura activa en el momento de la puesta en tensin (s )


viene dado por el menor valor de:
186kN = 1395 N / mm

= 0.75
0.75 f
100mm
s
158
kN = 1422 N / mm
0.90f = 0.90

100mm
po

max,k

po

pyk

El valor de la tensin mxima de la armadura activa para tiempo infinito (s ), vendr dado como
diferencia entre el valor en la puesta en tensin (s ) y las prdidas que se produzcan en el perodo
de tiempo. Una estimacin razonable de estas prdidas se puede situar entre el 15 y el 20%. Para
este caso tomaremos un valor intermedio del 17.5%, lo que conduce a:
pt

po

s = s - 0.175 s
pt

po

po

= 0.825 s

= 0.825 1395 N / mm = 1150.9 N / mm


2

po

Los autores, 1998; Edicions UPC, 1998.

373

Elementos Estructurales

1.2 Hormign

La tensin mxima en el hormign en la puesta en tensin debe cumplir las siguientes


recomendaciones:
f f1.6 = 0.625 f
Esta limitacin pretende evitar micofisuracin en el hormign que combinada con efectos
transversales pudiese conducir al agotamiento del hormign.
Ahora bien, este es un punto de vista de agotamiento y no considera que un nivel alto de tensiones
como el definido por la expresin anterior conducira a entrar en el rango de fluencia no lineal bajo
cargas mantenidas. Por ello es usual tomar valores inferiores que se siten en el rango lineal, el cual
para estos hormigones est entre el 30 y 40% de f . Haciendo la hiptesis de que la puesta en
tensin se realiza a los 7 das y considerando que el valor de f para esa edad es 0.70 f (28 das) y
tomando un porcentaje mayor del rango por el tipo de hormign:
ck , j

cu, j

ck , j

ckj

ck,j

s = 0.40 f
ci

ck , j

= 0.40 0.80f = 0.32 40 N


ck

mm = 12.8N / mm
2

ck

la tensin mxima en el hormign para tiempo infinito se tomar menor a la inicial (en esta caso, el
30% de f ). Con ello se pretende tener en cuenta el efecto del cansancio y de no trabajar en rangos
de tensiones que condujesen a problemas de fluencia no lineal.
ck

s = 0.3 f = 0.3 40 N
ct

ck

mm

= 12.0

N mm

Sustituyendo los valores de s , s , s , s obtenidos en las expresiones [4] y [5] se obtienen:


A 0.0091 A
[4]
A 0.0103 A
[5]
po

ps

ps

pt

ci

ct

Estas expresiones son rectas que se pueden representar grficamente, tal como se muestra en la
figura adjunta, con la denominacin a y a respectivamente, siendo ms restrictiva la primera de
ellas correspondiente a la puesta en tensin.
2 Margen de seguridad frente a fisuracin

Dado el mayor rango de corrosin bajo tensin en armaduras activas y las mayores consecuencias
negativas de esta corrosin, debemos tener un cierto margen de seguridad frente a la fisuracin que
denominaremos m . Este valor depender lgicamente del tipo de estructura, de la probabilidad de
sobrecarga y del riesgo asociado a la fisuracin (por ejemplo: depsitos de agua frente a edificios de
contencin de centrales nucleares). Este planteamiento se puede articular a travs de la siguiente
expresin:
fis

Los autores, 1998; Edicions UPC, 1998.

374

Hormign armado y pretensado. Ejercicios

fis

m N , donde:

[6]

fis

N es el esfuerzo axil que producira la fisuracin,


N es el esfuerzo axil total (250 kN + 175 kN=425 kN),
m es un valor que se fija en base a la experiencia. As por ejemplo si se toma m =1.5,
indicaremos con ello que se fisurar si se presenta un esfuerzo axil 50% mayor del
previsto. En este ejemplo tomaremos m =1.5.
El desarrollo de la expresin [6] da lugar a una curva como la que se seala en la figura adjunta
como b, si bien se puede obtener una expresin simplificada lineal, admitiendo en esta hiptesis que
A @ A @ A , recordando que A =A +n A , donde n = EE y A =A - A . Con esta hiptesis se
obtiene que la traccin del acero es:
T = A f + A s m N
fis

fis

fis

fis

ps

ps

ct

ps

ps

fis

y conduce a la expresin:
A - sf A + ms N
tc

ps

[6]

fis

pt

pt

donde f es la resistencia mnima a traccin del hormign, que segn la EHE viene dada
por 0.21 .Sustituyendo los valores correspondientes a este caso tendremos:
tc

f ck

ps

2.5 N / mm A - 1.5 425 kN


1150.9 N mm
1150.9 N / mm
2

= 0.0022 A - 554 mm

que se corresponde con la recta sealada como b en la figura adjunta. La curva b y la recta b tienen
un buen ajuste en la zona de estudio que interesa, lo que avala la hiptesis simplificativa realizada.
3 Margen de seguridad frente a descompresin

De forma anloga al planteamiento realizado en fisuracin tambin conviene poner un margen de


seguridad frente a descompresin para considerar que hay acciones que no se estn considerando
(por ejemplo: acciones indirectas de tipo trmico). La expresin equivalente a la que se llega en este
caso es:
N m N , donde:
[7]
des

des

N es el esfuerzo axil que descomprime la seccin,


N es el esfuerzo axil total,
m es el valor del margen de descompresin, que lgicamente debe ser menor que el
correspondiente a fisuracin. En este ejemplo tomaremos m = 1.2.
des

des

des

Los autores, 1998; Edicions UPC, 1998.

375

Elementos Estructurales

El desarrollo de esta expresin, que se puede consultar en la referencia citada de Naaman, conduce
a una curva sealada en la figura adjunta por la letra c. Ahora bien, haciendo la misma hiptesis
simplificativa que en el caso anterior (A @ A @ A ), tendremos para la traccin del acero:
T = A 0 + A s m N
t

ps

ps

des

Obtenindose la expresin equivalente:


A m N

[7]

des

ps

pt

en la que sustituyendo los valores correspondientes se obtiene la recta c, de la figura adjunta:


1.2 425 kN = 443 mm
A 1150
.9 N mm
2

ps

4 Armadura mnima

Con este criterio se pretende la existencia de una armadura mnima para evitar una rotura frgil en
el caso de que produzca fisuracin. El mismo se puede expresar mediante la ecuacin.
A N
[8]
ps

fis

Esta expresin difiere algo de la expuesta por Naaman, si bien corresponde al planteamiento
europeo en vez del tratamiento ACI seguido por dicho autor.
Si en esta expresin hacemos la hiptesis simplificada realizada con anterioridad en el apartado de
fisuracin se obtiene que:
A

-f

f -s

[8]

ct

ps

yk

pt

donde cada una de las variables tiene el significado dado con anterioridad.
Sustituyendo en esta expresin se obtiene
A

2.5 N mm
A = 0.0058 A

1580 - 1150.9
2

ps

que es una recta, representada en la figura adjunta por la letra d.

Los autores, 1998; Edicions UPC, 1998.

376

Hormign armado y pretensado. Ejercicios

5 Rotura armadura activa

Se debe verificar el estado lmite ltimo de agotamiento de la armadura activa por lo que se
plantear la ecuacin de equilibrio (sin contribucin alguna del hormign):
N A f
[9]
d

ps

ypd

donde: N corresponde a la mayoracin en los esfuerzos dada en la siguiente formulacin (la


consideraremos vlida para este caso):
N = 1.35 250 kN + 1.5 150 kN = 562.5 kN
f = fg = 1580
1.15 = 1374 N mm
d

ypk

ypd

en la que sustituyendo estos valores se obtiene


562.5 kN 409.4 mm
A 1374
N / mm
que est representada en la figura adjunta por la letra del dominio e.
2

ps

6 Limitacin deformaciones m ximas

Este criterio permite garantizar una deformacin Dl (alargamiento o acortamiento) bajo una carga
dada o una combinacin de cargas. Estas deformaciones deben ser compatibles con las condiciones
de contorno.
La deformacin axial fruto de una carga variable deber estar condicionada por la deformacin
permitida en la condicin de contorno. As:
-N l
N l Dl
-Dl o
[10]
E A
E A
en el que sustituyendo A por su valor (A = A +(n-1)A , y n = EE = 6 ) se obtiene la expresin:
A - nA- 1 + (n -N1)E l Dl
[10]
v

ps

ps

Una expresin similar se puede obtener si se plantean las deformaciones diferidas correspondiente a
la N .
Para el presente ejercicio consideraremos un incremento del 40% de la carga variable (245 kN) y un
lmite de incremento de deformacin de Dl= - 3.75 mm, que sustituyendo en [10] se obtiene
v

Los autores, 1998; Edicions UPC, 1998.

377

Elementos Estructurales

ps

A + 245 10 N 30 10 mm -0.2A + 12060 mm


5 5 32.5 10 N mm 3.75mm
3

que es una recta, representada en la figura adjunta por la letra f.


Con todos los dominios definidos por las ecuaciones de los criterios analizados se obtiene un
dominio de soluciones posibles como el de la figura adjunta.
Al conjunto de soluciones posibles se le podra aadir una funcin de mnimos costes de materiales
y a puesta en obra. Ello conduce a una recta de pendiente negativa que intersectara con el dominio
posible, en este caso en el punto B.
As pues, la solucin de mnimo coste viene dada por:
A = 580 cm
A = 443 mm
2

ps

A esta solucin de clculo se le debe ajustar una solucin prctica en la realidad. Por ello como
geometra se propone adoptar una seccin cuadrada de 25 cm de lado (A =625 cm ), y si se matan
las esquinas con berenjenos de 4 cm para evitar riesgos de rotura por golpes, se obtendr un rea
geomtrica de 593 cm (superior a la de clculo).
g

Los autores, 1998; Edicions UPC, 1998.

378

Hormign armado y pretensado. Ejercicios

En cuanto al rea de la armadura activa (A ), cada cordon de 0.5 de 7 alambres tiene un rea de
100 mm , por lo que se requerir 5 cordones (A =500 mm ). Ello conduce a un tendn de 5
cordones, con un peso de 3.93 kg/m lineal; una vaina de 45 mm de dimetro interior y una
evaluacin de la inyeccin en lechada de cemento de 1.5 kg/m lineal. En los catlogos de las firmas
comerciales se definen los detalles de la geometra de placas la anclaje, trompetas, etc.
ps

ps

Los autores, 1998; Edicions UPC, 1998.

379

Elementos Estructurales

Ejercicio III-7 Viga de gran canto

Dada la viga continua de la figura adjunta


pp+ cp= 100 kN/m
2.8 m
0.4

5.6

0.4

5.6

Con las caractersticas de los materiales siguientes:


- hormign H-25/20/P/IIaf = 25 MPa
- acero B 400 S
f = 400 MPa
Se considera un nivel de control normal.

0.4

5.6

0.4

ck

yk

Se pide:

1. Definir el ancho de la viga.


2. Calcular la totalidad de armadura necesaria.
3. Dibujar a escala el armado de la viga.
Segn la Instruccin EHE, se consideran como vigas de gran canto las vigas rectas, generalmente
de seccin constante, y cuya relacin entre la luz y el canto total es inferior a 2 en vigas
simplemente apoyadas, a 2.5 en vigas continuas.
La luz de un vano que se considera es el mnimo entre la distancia entre ejes de apoyos (6.0 m) y
1.15 veces la luz libre (1.155.6 = 6.44 m). En nuestro caso, se considera como luz l=6.0 m.
Dado que el canto es de 2.8 m, la relacin luz/canto es l/h=6/2.8=2.14. Como este cociente es
inferior a 2.5 se trata de una viga continua de gran canto, de tres tramos.
As pues, se trata de una regin de discontinuidad generalizada, donde no son vlidas las hiptesis
de Bernouilli. El anlisis de este tipo de regiones D se puede llevar a cabo mediante el Mtodo de
las Bielas y Tirantes, tal como indica la instruccin EHE.

Los autores, 1998; Edicions UPC, 1998.

380

Hormign armado y pretensado. Ejercicios

En el caso particular de este ejercicio (viga de gran canto continua y sometida a una carga
uniformemente distribuida en la cara superior) se propone el siguiente modelo:
p = 1.5(pp + cp) = 1.5100 = 150 kN/m
d

0.2 l

0.35h

0.4 l

1.8

1.2

2.4

p =1.5(cp + pp) =1.5*100 =150

0.98
0.20 pdl
0.5h=1.4

h =2.8

0.16 pdl

0.14

0.09 pdl

0.05h
6

l =6

Solucin

1 Ancho de viga

La anchura mnima est limitada por el valor mximo de la compresin de los nudos y las bielas. En
este caso, la mxima compresin viene provocada por la reaccin en un apoyo interior:
R
s
=
a b
con:
R = 1.1p l = 1.11506 = 990 kN (reaccin de clculo en apoyo interior)
a = 0.4 m (dimensin longitudinal del apoyo)
b = ancho de la viga.
Esta compresin ha de ser inferior a f =0.7f =0.716.67 =11.67 MPa, por lo que el ancho de
la viga ha de ser superior a:
b a R f = 400990000
= 212 mm
11.67
i ,d

c,max

i,d

1cd

cd

i,d

1cd

Imponiendo que la esbeltez geomtrica, entendida como el cociente entre la longitud de pandeo y el
ancho de la viga, sea menor que 12, se obtiene el ancho de la viga que evita la comprobacin del
pandeo fuera del plano de la viga.
b > l /12 = 3311/12 = 276 mm
0

Los autores, 1998; Edicions UPC, 1998.

381

Elementos Estructurales

donde l es la longitud de pandeo. Al tratarse de un modelo formado por barras articuladas, este
valor coincide con la longitud de la biela, que en este caso alcanza su valor mximo en 3311 mm.
La necesidad de un ancho mnimo tambin puede venir dado por razones constructivas. Veamos
desde este punto de vista el orden de magnitud de esta dimensin. Para ello hagamos la hiptesis de
que dicho elemento se hormigonar en configuracin final, mediante vertido directo desde la parte
inferior.
En la figura adjunta se muestran las dimensiones de cada componente transversal.
o

r = 20 mm de acuerdo con la tabla 37.2.4, dado que tipo


hormign elemento y ambiente.
= 10 mm orden de magnitud definido a priori
= 10 mm orden de magnitud definido a priori
S = 80-100 cm orden de magnitud requerido para entrada de
hormign en cada libre y colocacin de vibrador interior.
b 2 (r + + + S) = 2 (20 + 10 + 10 + 80) = 240 mm
este valor es, en este caso, menos condicionante que el anterior,
por lo que se tomar aqul redondeando por exceso. As pues, el
ancho para el problema es 280 mm, si bien podra adaptarse 300
mm de cara a facilitar geomtricamente mltiplos de 5 que son
ms usuales.
1
2

2
1

2 La armadura

Segn el modelo de bielas y tirantes adoptado para el anlisis de la viga de gran canto, la armadura
principal que se ha de disponer es la siguiente:
2.1 Armadura de vano interior

En el vano interior donde el momento flector positivo es menor se proyecta para una fuerza de valor
0.09p l = 0.091506 = 81 kN, resultando una armadura necesaria de A = 233 mm . Se
dispondrn por tanto 3f10.
d

2.2 Armadura de vano exterior

La fuerza que se ha de considerar en este caso de acuerdo con el modelo de la EHE es 0.16p l =
0.161506 = 144 kN, siendo el rea de armadura necesaria:
d

A = 414 mm . A = fT . Se dispondrn 3f10 y 2f12.

yd

Los autores, 1998; Edicions UPC, 1998.

382

Hormign armado y pretensado. Ejercicios

2.3 Zona de apoyos intermedios

Esta zona est traccionada por encima de los apoyos intermedios (ver la figura), y la armadura se
proyecta para una fuerza de traccin de valor 0.20p l=0.201506=180 kN:
A f = T = 180 de donde A = 180000
348 = 517 mm Son necesarias por tanto 7f10, que
se dispondrn como f10 cada 10 cm.
Por otra parte, adems de la armadura principal, se ha de disponer una armadura mnima de 0.1%
de cuanta en cada direccin y cada cara del elemento (armadura secundaria):
A = 0.001(280mm1000m) = 280 mm /m
Ello responde a que dado que no se calcula frente a acciones indirectas, siempre existe una
armadura mnima que evita roturas frgiles.
Para el clculo de las zonas de apoyo, de acuerdo con el artculo 60 de la instruccin EHE, referido
a cargas concentradas sobre macizos, si no se dispone armadura de confinamiento, la fuerza mxima
de compresin ser el menor de los siguientes valores:
N = A f = A 0.7f = 40028011.67 =1307040 N = 1307 kN
f f = 400 280 0.85 1 - 25 16.67
N =A f = A 0.85 1 - 250

250

N = 1428286 N = 1428 kN
siendo A el rea en el apoyo.
N es superior en cualquier caso a la reaccin mxima en apoyos (N = 990 kN). Por lo tanto,
no es necesario reforzar esta zona de apoyos.
d

yd

sec

c1

c1

2cd

1cd

c1

cd

ck

c1

cd

c1

d,max

3 Armado de la viga

La armadura que se dispone finalmente es la que se aprecia en la figura. El dimetro base de


armadura que se propone es de 10 mm, excepto la armadura de los vanos exteriores resuelto con 3
10 + 2 12.
10 cada 20 cm

3 10 2 12

3 10

10 cada 20 cm

3 10

2 12

Los autores, 1998; Edicions UPC, 1998.

383

Elementos Estructurales

Ejercicio III-8 Mnsula corta para puente-gra


Un puente-gra de 100 kN se apoya sobre una mnsula corta con las dimensiones que se indican en
la figura.

40

Fv

FH

10

45
80 cm

50

50

Las acciones a las que se ve sometida la mnsula son:


- accin vertical del puente-gra de 100 kN (Fv),
- accin horizontal de frenado del carro de 15 kN (FH).
Se considera un hormign HA-25/P/12/I y un acero B 500 S.
Los coeficientes de seguridad que se utilizarn sern los correspondientes a un nivel de control
normal.

Se pide:
1. Calcular la armadura que es necesario disponer para hacer frente a las acciones provocadas por el
puente-gra.
2. Proponer una disposicin del armado de la mnsula.

Solucin

1 Armadura
Para que el elemento estructural considerado se pueda considerar como una mnsula corta, se han
de verificar unas determinadas condiciones geomtricas.

Los autores, 1998; Edicions UPC, 1998.

384

Hormign armado y pretensado. Ejercicios

En primer lugar, la distancia entre la lnea de accin de la carga vertical principal y la seccin
adyacente al soporte ha de ser menor o igual que el canto til en dicha seccin. En el caso del
ejemplo, la distancia que se ha de considerar toma el valor de a=40 cm, siendo el canto til d=70
cm. As pues, se satisface esta primera condicin.
Por otra parte, el canto til medido en el borde exterior del rea donde se aplica la carga ha de ser
mayor o igual que la mitad del canto til en la seccin adyacente al soporte. El primero de ellos es
d1=38.5 cm, mientras que 0.5d=35 cm.
Considerando un coeficiente de seguridad

= 1.5, se obtienen los siguientes valores de clculo

para las cargas actuantes en el elemento:


FHd =
FVd =

g
g

FH = 22.5 kN

FV = 150 kN

Se adopta el siguiente modelo de bielas y tirantes:

Se considera que la mnsula se hormigona monolticamente con el pilar. Por lo tanto, se toma un

valor del ngulo de inclinacin de la biela tal que cotg

= 1.4. Este valor representa el coeficiente

de rozamiento entre dos hormigones.


1.1 Dimensionamiento de la arm adura
La armadura est compuesta por una armadura principal y por unos cercos horizontales.
La armadura principal ha de poder absorber una traccin de clculo de valor:

-1

Tu1 = FVdtg +FHd = 1501.4

+ 22.5 = 129.64 kN

As = Tu1 / fyd = 298 mm , que se pueden obtener disponiendo 3 12.


Los cercos horizontales deben absorber una traccin total de valor:

Los autores, 1998; Edicions UPC, 1998.

385

Elementos Estructurales

0.25FVdsen

q = 0.25150(1+1.4 )

2 -1

= 12.67 kN

Ase = 29.14 mm , que se consigue colocando cercos

f8 cada 15 cm.

1.2 Comprobacin de nudos y bi elas


Dado que se verifica la siguiente expresin:

a
0.85

cot gq

d = 70 cm
a = 40 cm
70 cm

40
0.85

1.4 = 65.9 cm

nicamente se ha de comprobar la compresin localizada en el apoyo:


FVd

b c

=5

N
mm

11.67 = f

1cd

donde:
FVd = 150 kN
b = 100 mm
c = 300 mm

Dimensiones del apoyo

f1cd = 0.7016.67 = 11.67 MPa


Esta expresin es vlida si FHd = 22.5 kN

0.15F

Vd

= 22.5 kN

2 Disposicin del armado


Se propone la siguiente disposicin del armado:

A esta armadura (efecto local mnsula) hay que superponer la que corresponda como elemento
estructural. Todo ello puede implicar que dicha zona sea fuertemente armada, recomendndose en
ese caso estudiar sistemas de racionalizacin de armado que favorezcan el vertido y compactacin
del hormign.

Los autores, 1998; Edicions UPC, 1998.

387

Elementos Estructurales

Ejercicio III-9 Punzonamiento de una placa en un pilar

El forjado de un edificio de viviendas consiste en una placa maciza de hormign armado sustentada
sobre soportes aislados. Considrese un pilar interior de seccin 25x25 cm unido a la placa de 23
cm de canto, sometido a un axil de clculo de 750 kN.
Las propiedades de proyecto de los materiales son:
- hormign HA-25/P/12/I
- armaduras B 400 S
Se supone una cuanta de armadura longitudinal en la losa en ambas direcciones de valor r=0.5%.
2

Se pide:

1. Determinar si es necesario disponer armadura de punzonamiento.


2. Calcular, en su caso, dicha armadura y hacer un esquema de disposicin de la misma.
Solucin

1 Determinacin de la necesida d de la armadura de punzonamiento

En primer lugar se ha de determinar el rea crtica. sta viene definida a partir del canto til y de
un permetro crtico.
El canto til es de 20 cm, mientras que el permetro crtico se sita a una distancia igual a dos veces
este canto til (2d = 40 cm) del permetro del soporte.

Para comprobar si es necesario disponer armadura de punzonamiento, se ha de verificar que:


t t
sd

rd

Los autores, 1998; Edicions UPC, 1998.

388

Hormign armado y pretensado. Ejercicios

donde t es la tensin tangencial nominal de clculo y t es la tensin tangencial mxima resistida.


F = 1.228 MPa
t =
u d
F = bF = 862500 N (esfuerzo efectivo de punzonamiento de clculo)
b=1.15 (soporte interior)
F = 750000 N (esfuerzo de punzonamiento de clculo)
u = 4250+2p400 = 3513.3 mm
d = 200 mm
t = 0.12x(100r f ) = 0.122(100510 25) = 0.557 MPa
r = 510
200 =1 + 200 = 2
x =1+
d
200
sd

rd

sd ,ef

sd

sd,ef

sd

sd

rd

1/3

ck

-3

1/3

-3

Como t > t , es necesario disponer armadura de punzonamiento.


sd

rd

2 La armadura

Deben realizarse tres comprobaciones: una en la zona con armadura transversal, otra en la zona
adyacente sin dicha armadura y verificar la resistencia mxima.
En primer lugar se debe estimar el nmero de permetros concntricos de armadura de
punzonamiento que se dispondrn, o lo que es lo mismo, se ha de determinar hasta dnde es
necesario disponer dicha armadura. Para ello se procede a la comprobacin de la zona exterior a la
armadura de punzonamiento.
2.1 Zona exterior a la armadura de punzonamiento

En esta zona se ha de verificar que:


F , 0.12x(100r f ) u d
Por lo tanto, el permetro u se puede obtener mediante la expresin siguiente:
F
750000
u
=
0.12 x (100 r f ) d 0.12 2 (100 5 10 25) 200
u = 6732.6 mm
F , = F = 750000 N , puesto que se supone que a la distancia en la que se comprueba
esta condicin el efecto del momento transferido entre soporte y losa por tensiones
tangenciales ha desaparecido, y nicamente se tiene en cuenta el efecto debido a la carga.
Al tratarse de un soporte interior, este permetro se corresponde con el de un cuadrado de lado
u /4= 6732.6/4 = 1683.2 mm.
sd ef

ck

1/3

n,ef

n,ef

sd,ef

n ,ef

1/ 3

ck

n,ef

sd ef

sd

n,ef

Los autores, 1998; Edicions UPC, 1998.

-3

1/ 3

389

Elementos Estructurales

Segn la instruccin EHE, la distancia entre el primer permetro de armadura de punzonamiento y


la cara del soporte ha de ser inferior a 0.5d=100 mm, mientras que las distancias entre los
diferentes permetros no han de exceder de 0.75d=150 mm.
Por ejemplo, se puede intentar disponer tres permetros con una separacin entre permetros s=130
mm, que es inferior a 0.75d=150 mm. Para ello se puede disponer un primer permetro formado
por 4 barras por lado separadas entre s por 130 mm, resultando entonces que la distancia entre el
permetro y el paramento del soporte es 3 1302- 250 = 70 mm , inferior a 0.5d=100 mm.
As pues, una posible disposicin de la armadura de punzonamiento es:
- primer permetro a 70 mm del paramento del soporte, formado por 12 barras;
- segundo permetro a 130 mm del primero, formado por 20 barras;
- tercer permetro a 130 mm del segundo, y formado por 28 barras.

En este caso, u = 4(7s + 2(2d)) = 4(7130+2(2200)) = 6840 mm. Por lo tanto, no es


necesario disponer armadura de punzonamiento a partir del tercer permetro, que es lo que se quera
verificar.
Una vez se ha decidido en qu zona es necesario colocar la armadura de punzonamiento, as como
la disposicin concreta de sta, se puede proceder a su dimensionamiento.
n,ef

2.2 Zona con armadura de punz onamiento

El esfuerzo cortante de agotamiento consta de una parte resistida por el hormign y otra parte que
ha de absorber la armadura. Para el dimensionamiento de la armadura se hace que el esfuerzo de
agotamiento sea igual a la solicitacin:
V =V +V =F
La contribucin del hormign se puede estimar mediante la expresin:
V = 0.10x(100r f ) b d = 0.102(100510 25) 3513200= 326146 N
200 =1 + 200 = 2
x =1+
d
200
u2

cu

su

cu

sd,ef

ck

1/3

-3

Los autores, 1998; Edicions UPC, 1998.

1/3

390

Hormign armado y pretensado. Ejercicios

= 510
b = u = 3513.3 mm
d = 200 mm
Por lo tanto, la armadura ha de ser capaz de resistir:
V = Aaf a 0.9d = F - V = 862500 - 326146 = 536354 N
A = As = f V 0.9 d = 8.57 mm / mm = 85.7 cm / m
f a = f = 347.83 MPa
Con la disposicin de armadura adoptada ( s=130 mm), se obtiene que el rea total de armadura de
punzonamiento en un permetro concntrico al soporte ha de ser:
A = Aas= 11.14 cm
En el primer permetro este rea total de armadura se puede conseguir colocando f12. En el resto
de permetros la armadura necesaria es menor, pero se continan disponiendo barras del mismo
dimetro, puesto que no es conveniente reducir excesivamente el dimetro de las barras y adems se
facilita el montaje.
Esta armadura de punzonamiento estar constituida por barras dobladas.
r

-3

su

y ,d

,d

sd,ef

sw

cu

su

ya,d

yd

sw

2.3 Resistencia mxima

Finalmente, cabe comprobar que el esfuerzo mximo de punzonamiento no supera un cierto lmite.
Se ha de verificar que:
F f
u d
F = 862500 = 4.312 MPa
u d (4 250 ) 200
f = 0.30f = 5 MPa
As pues, tambin se satisface la condicin de resistencia mxima.
La disposicin final de las armaduras es la que se indica en la siguiente figura.
sd ,ef

1cd

sd ,ef

1cd

cd

130 mm
12

130 mm

70 mm

d = 200 mm
250 mm

130 mm< 0.75d

Los autores, 1998; Edicions UPC, 1998.

0.5d > 70 mm

391

Elementos Estructurales

Ejercicio III-10 Punzonamiento de placas bajo cargas concentradas


La placa representada en la figura se encuentra sometida a la accin de su peso propio y de la carga
repartida Q, que acta sobre la zona rectangular de dimensiones b y c cuyo centro es el punto P0.
En esta zona se produce una flexin considerable.
Una vez dimensionada la placa frente al estado lmite ltimo de flexin, se plantea la comprobacin
de la placa frente al punzonamiento.
Las caractersticas de los materiales son:
- acero B500 S, fyk = 500 MPa
- hormign HA-25/B/18/IIa
En la zona de la carga concentrada las caractersticas de las armaduras son:
- cuantas:

r = 4.6
x

/oo,

r=3
y

/oo,

- cantos tiles: dx= 0.46 m, dy=0.44 m. Canto total: h = 0.5 m

Po
c
lx = 5 m; ly = 12 m

c = 1 m; b = 2 m

l y

P0 (x,y) = (2m, 8.5m)


2

Qk = 600 kN/m

l x

Y
X
Se pide:
Realizar la comprobacin de la placa frente al punzonamiento.

Los autores, 1998; Edicions UPC, 1998.

Borde libre
Borde empotrado
Borde apoyado

392

Hormign armado y pretensado. Ejercicios

Solucin
La superficie crtica de punzonamiento (permetro u1) se sita a 2d del rea cargada:

bs
2d

2d

g2

2d

cu1
2d

<6d

bi

tg

>6d

tg

g
g

= 0.235

= 0.571

g1
bu1

Los lados del permetro crtico bsico bu1 y cu1, paralelos a los lados b y c del rea cargada, son
(tomando el canto til medio):

b u1
c u1

=
=

b
c

+ 2 ( 2 d ) = 3 .8 m
+ 2 ( 2 d ) = 2 .8 m

El permetro crtico, sin embargo, se ve reducido por la proximidad del borde libre segn se
observa en la figura. Resulta, finalmente, el siguiente valor de u1:

(
+(

)
)

bs

= b 2 + 2d +

2d

+ c 2 tg g = 2.70 m

bl

= b 2 + 2d

2d

+ c2

u1
Calculamos

= 7.73 m
t

sd

tg

g = 2.23 m
1

(tensin tangencial nominal de clculo en el permetro crtico), incluida la carga de

peso propio en la zona cargada:


Fsd,ef = esfuerzo efectivo de punzonamiento de clculo
Fsd ,ef

t =
sd

= 1.35 b c h 25 kN / m + 1.5 b c 600 kN / m = 1979.55 kN


3

u1

Fsd,ef
u1

u1

= 569.08 kN / m = 0.569 MPa


2

Los autores, 1998; Edicions UPC, 1998.

393

Elementos Estructurales

Se calcula

, capacidad resistente del hormign en el permetro crtico:

rd

t = 0.12 x (100 r f
d +d
d =
= 0.45 m
rd

ck

200

x =1+

= 1.67

rl = r r = 0.0037
x

, de donde

t = 0.421 MPa
rd

Dado que se sobrepasa la capacidad resistente del hormign en el permetro crtico, es necesario
disponer armadura frente a punzonamiento. Deben estudiarse dos zonas:
a) Zona con armadura de punzonamiento.
Se calculan Asw, el rea de la armadura de punzonamiento en un permetro concntrico al del rea
cargada. Se trata el dimensionamiento del mismo modo que frente a esfuerzos cortantes, donde:
bo

=u

Aa

A sw
s

Asw es la armadura total frente al punzonamiento y s es la separacin entre dos permetros


concntricos de armadura.
Vu 2

=V +V
cu

su

= 0.10 x (100 r f ) b d = 1219.4 kN


- V = 760.15 kN
V =F
V = A a f a z sen a (cot ga + cot gq)
q @ 45 y a @ 90
z @ 0.9 d = 0.4 m
1/ 3

Vcu

ck

su

sd,ef

su

f ya,d

Aa

cu

y ,d

500 MPa
1.15

= 43.71

cm

= 434.78 MPa

La disposicin clsica de armadura transversal vertical es la que aparece en la figura:

Los autores, 1998; Edicions UPC, 1998.

394

Hormign armado y pretensado. Ejercicios

0.75d
0.75d
0.5d

Tomando como valor de s=300 mm, se tiene una armadura de punzonamiento de 13.11 cm para un
2

permetro concntrico al rea cargada: Asw=Aas=13.11 cm . As pues, una posible disposicin de


armadura de punzonamiento es:
-

primer permetro a 230 mm del rea cargada, formado por 17 barras

segundo permetro a 300 mm del primero, formado por 21 barras

tercer permetro a 300 mm del segundo, formado por 25 barras.

Como en el primer permetro el rea total de armadura se cubre con

f10,

y en el resto de los

permetros aunque se dispone ms armadura de la necesaria, se opta tambin por barras

f10,

ya que

no conviene reducir excesivamente el dimetro de la armadura.

f10/30

cm

300 mm
300 mm
230 mm
rea
cargada

b) Zona sin armadura de punzonamiento


En la zona exterior a la armada el hormign debe resistir el esfuerzo sin presencia de armadura.
Debe verificarse que:

Fsd ,ef

0.12 x (100 r f
1

) u
1

ck

n ,ef

donde un,ef es el permetro que aparece en la figura:

Los autores, 1998; Edicions UPC, 1998.

395

Elementos Estructurales

n,ef

2d

un,ef

@ (9 x 3) 300 mm +4 (2d) = 11.7 m

El valor de un,ef resulta ser de 11.7 m y, teniendo en cuenta el peso propio de toda el rea en
estudio, resulta:
Fsd,ef

= 2172.6 kN < t u
rd

n ,ef

d = 2216.6

kN , luego cumple.

Por ltimo debe comprobarse que el esfuerzo mximo de punzonamiento no supera el valor:
Fsd ,ef
u0

1cd

donde f1cd es la resistencia a compresin del compresin del hormign (f1cd = 0.3 fcd) y u0 es el
permetro que aparece en la figura:

uo

Se tiene as,
u0 = 3.403 m

f1cd = 0.3 25 MPa / 1.5 = 5 MPa

Fsd,ef = 1.35 1m 2m 0.5m 25 kN/m + 1800 kN = 1833.8 kN


Fsd,ef
u0d

= 1.20 MPa , que cumple sin problemas.

Los autores, 1998; Edicions UPC, 1998.

397

Elementos Estructurales

Ejercicio III-11 Racionalizacin del armado I

En el encauzamiento de una riera se plantea una solucin mediante un muro de seccin constante de
900 metros de longitud. Al tratarse de una obra lineal se pretende industrializar el armado a fin de
aumentar los rendimientos de ejecucin, utilizando malla electrosoldada.

Un panel de malla especial tiene, tanto en la direccin longitudinal como en la transversal, unos
sobrelargos o patillas, de unas dimensiones iguales a la longitud de solapo correspondiente por un
lado, y de una longitud igual o sensiblemente igual a la trama por el otro.
L: longitud de las barras longitudinales
ai: sobrelargo longitudinal de longitud
igual o sensiblemente igual a la trama
ad: sobrelargo longitudinal de longitud
igual a la longitud de solapo
T: longitud de las barras transversales
bi: sobrelargo transversal de longitud
igual o sensiblemente igual a la trama
bd: sobrelargo longitudinal de longitud
igual a la longitud de solapo
Datos: - hormign H-250.
- acero B-500-S.

Los autores, 1998; Edicions UPC, 1998.

398

Hormign armado y pretensado. Ejercicios

- juntas de construccin cada 9 metros (junta con armadura pasante)


- juntas de dilatacin cada 18 metros (junta sin armadura pasante)
- recubrimiento de armaduras = 3 cm
- dimensiones mximas de los paneles de malla electrosoldada:
9 metros en la direccin longitudinal
2.45 metros en la direccin transversal.
- cuantas de armadura:
Zapata Armadura principal inferior: 3.14 cm /m
Armadura reparto inferior: 2.50 cm /m
Armadura principal superior: 5.655 cm /m
Armadura reparto superior: 3.14 cm /m
Alzado: Armadura principal interior: 5.655 cm /m
Armadura reparto interior: 3.80 cm /m
Refuerzo interior a 1/3 de la altura: 4.95 cm /m
Armadura principal exterior: 3.90 cm /m
Armadura reparto exterior: 2.50 cm /m
- rendimientos de colocacin:
Ferralla tradicional: 80 Kg / persona / hora
Malla especial: 240 Kg / persona / hora
2

Se pide:

1.
2.
3.

Solucin mediante malla electrosoldada especial. Plantear una racionalizacin del armado
mediante mallas electrosoldadas especiales.
Solucin tradicional. Plantear una racionalizacin del armado mediante ferralla tradicional.
Segn el plan de obra, se pretende armar dos tramos de 18 metros por la maana (5 horas) para
hormigonar por la tarde. Cuntos operarios son necesarios en la solucin propuesta con malla
especial? Comparar con la solucin en ferralla tradicional.

Solucin

1 Solucin mediante malla elec trosoldada especial


1.1 Determinacin de dimetros de barras y separaciones

En la siguiente tabla se tienen los valores de las cuantas geomtricas de armadura para distintos
dimetros y separaciones de barras.

Los autores, 1998; Edicions UPC, 1998.

399

Elementos Estructurales

Cuantas de armadura (cm / m)


(mm) A (cm )
Sep. = 10 cm Sep. = 15 cm Sep. = 20 cm Sep. = 25 cm
6
0.283
2.83
1.887
1.415
1.132
8
0.503
5.03
3.353
2.515
2.012
10
0.785
7.85
5.233
3.925
3.14
12
1.131
11.31
7.54
5.655
4.524
A partir de las cuantas de armadura se obtienen las siguientes disposiciones de armadura:
Zapata Armadura principal inferior: f10 cada 25cm
3.14cm 3.14cm
Armadura reparto inferior:
f8 cada 20cm
2.515cm 2.50cm
Armadura principal superior: f12 cada 20cm
5.655cm 5.655cm
Armadura reparto superior:
f10 cada 25cm
3.14cm 3.14cm
Alzado Armadura principal interior: f12 cada 20cm
5.655cm 5.655cm
Armadura reparto interior:
f10 cada 20cm
3.925cm 3.80cm
Refuerzo alzado interior:
f12 cada 20cm
5.655cm 4.95cm
Armadura principal exterior: f10 cada 20cm
3.925cm 3.90cm
Armadura reparto exterior:
f8 cada 20cm
2.515cm 2.50cm
f

1.2 Clculo de longitudes de sola po

Para el clculo de las longitudes de solapo se utiliza la expresin de la normativa espaola para
barras en posicin II (65.5.2., EHE), teniendo en cuenta que ms del 50% de las barras
traccionadas se solapan en la misma seccin. Considerar posicin II en todos los solapos conduce a
un pequeo aumento del consumo de acero pero a una mejor racionalizacin del armado.
Longitud de solapo = a l = 1.4 l
f f 15 cm
l = 1.4 m f 140
bII

bII

bII

yk

Se obtienen para las barras de dimetro 8, 10 y 12 mm unas longitudes de solapo de 40, 50 y 60 cm


respectivamente.
1.3 Modulacin de los paneles

Dadas las dimensiones de la seccin transversal del muro, en el alzado y la zapata es conveniente
disponer los paneles de malla electrosoldada de forma transversal. Es decir, con su dimensin
menor en la direccin longitudinal del muro.
Es necesario diferenciar las dimensiones longitudinal y transversal de paneles y muro. stas
coincidirn o no en funcin de la disposicin de los paneles de malla en el elemento estructural.
Para determinar las dimensiones del panel que se quiere emplear en el armado se utiliza la siguiente
ecuacin:

Los autores, 1998; Edicions UPC, 1998.

400

Hormign armado y pretensado. Ejercicios

n A - (n - 1) S = L

donde: n es el nmero de paneles de malla electrosoldada que se deben disponer


A es la anchura del panel
S es la longitud de solapo de la barra correspondiente
L es la longitud del elemento estructural que se debe ocupar por los paneles de malla.
T

Para una longitud L =17.94 m (distancia entre juntas sin armadura pasante menos el recubrimiento
a ambos lados) se obtiene, en funcin del dimetro de las barras para solapar, la siguiente
disposicin de paneles para cada tramo de 18 m de encauzamiento:
f8 9 paneles de 2.35 m de anchura
f10 9 paneles de 2.44 m de anchura.
Se utiliza la siguiente designacin de paneles, teniendo en cuenta que la mayor dimensin del panel
se denomina longitudinal y que la menor dimensin se denomina transversal:
S x S f - f de L x T
T

donde: S : separacin entre barras longitudinales,


S : separacin entre barras transversales,
f : dimetro de las barras longitudinales,
f : dimetro de las barras transversales,
L : longitud de las barras longitudinales,
T : longitud de las barras transversales.
La racionalizacin de la armadura del muro mediante el empleo de malla electrosoldada especial
puede verse en el siguiente grfico de la seccin transversal:
L
T

L
T

Los autores, 1998; Edicions UPC, 1998.

401

Elementos Estructurales

A continuacin se indican las caractersticas de los paneles de malla especial necesarios:


Malla inferior zapata 25 x 20
f 10 8de
3.24 x 2.35 m
28.99 Kg / panel
9 paneles / tramo
( ZAP.INF )

Malla superior zapata 20 x 25


f 12 10
de 3.48 x 2.44 m
Esta malla tiene unas patillas laterales de 37 cm de largo. Estas patas, adems de actuar de anclaje y
evitar la fisuracin del lateral de la zapata, se prolongan hasta la cota inferior de la zapata para fijar
la armadura en su posicin definitiva.
47.46 Kg / panel
9 paneles / tramo
( ZAP.SUP )
Malla alzado exterior

20 x 20

f 10 8de

3.12 x 2.35 m

Los autores, 1998; Edicions UPC, 1998.

402

Hormign armado y pretensado. Ejercicios

Esta malla tiene un sobrelargo en la zona de solapo con la espera. Las barras de reparto que faltan
se disponen en la espera.
30.36 Kg / panel
9 paneles / tramo
( ALZ.EXT )

Malla espera exterior 20 x 20


f 8 10de
2.35 x 1.05 m
Esta malla se realiza con el sobrelargo suficiente para poder ser hincada en la zapata. En la parte
superior que se solapa con el alzado, se disponen barras longitudinales de dimetro 10 mm que adems
de mantener la rigidez de la malla forman parte de la armadura de reparto interior del alzado.
9.26 Kg / panel
9 paneles / tramo
( ESP.EX )

Malla alzado interior 20 x 20


f 12 10
de 3.12 x 2.44 m
Esta malla tiene un sobrelargo en la zona de solapo con la espera. Las barras de reparto que faltan
se disponen en la espera.
45.77 Kg / panel
9 paneles / tramo
( ALZ.INT )

Malla espera interior

20 x 20

f 10 12

de

Los autores, 1998; Edicions UPC, 1998.

2.44 x 1.15 m

403

Elementos Estructurales

Esta malla se realiza con el sobrelargo suficiente para poder se hincada en la zapata. En la parte
superior que se solapa con el alzado, se disponen barras longitudinales de dimetro 10 mm que
adems de mantener la rigidez de la malla forman parte de la armadura de reparto interior del
alzado.
14,73 Kg / panel
9 paneles / tramo
( ESP.INT )

Malla refuerzo interior 40 x 20


f 8 12
de 5.98 x 1.55 m
Esta malla est realizada con redondos de montaje de 8 mm de dimetro en la direccin
longitudinal, y con un sobrelargo de 60 cm para permitir el hincado en la zapata.
48.38 Kg / panel
3 paneles / tramo
( REF.INT )

Malla separador
30 x 20
f 8 8 de 5.98 x 1.10 m
Malla que se utiliza para separar las mallas superior e inferior de la zapata. Esta malla debe tener
rigidez suficiente para permitir el hormigonado y vibrado de la zapata sin que se produzcan
deformaciones que lleven a una prdida del canto til.

22.48 Kg / panel
3 paneles / tramo

Los autores, 1998; Edicions UPC, 1998.

404

Hormign armado y pretensado. Ejercicios

Gracias a la geometra de estos paneles de malla electrosoldada especial, se lograr una colocacin
rpida de la armadura. El procedimiento de colocacin consiste en que una vez colocado el primer
panel, el sobrelargo corto del segundo panel, ya sea el transversal o el longitudinal, debe tocar la
ltima barra longitudinal o transversal del primer panel.
2 Solucin con ferralla tradicio nal

La disposicin de armaduras utilizando ferralla tradicional es la siguiente:

En la tabla siguiente se realiza el despiece de la armadura de la solucin con ferralla tradicional:


Zapata

Alzado

1
2
3
4
5
6
7
8
9
10
11

Armadura principal inferior


Armadura reparto inferior
Armadura principal superior
Armadura reparto superior
Armadura principal interior
Armadura reparto interior
Armadura espera interior
Refuerzo alzado interior
Armadura principal exterior
Armadura reparto exterior
Armadura espera exterior

Los autores, 1998; Edicions UPC, 1998.

f10

8
f12
f10
f12
f10
f12
f12
f10
f 8
f10

cada 25 cm
cada 20 cm
cada 20 cm
cada 25 cm
cada 20 cm
cada 20 cm
cada 20 cm
cada 20 cm
cada 20 cm
cada 20 cm
cada 20 cm

405

Elementos Estructurales

3 Solucin mediante malla elec trosoldada especial


3.1 Medicin del armado:

El montaje de la armadura teniendo en cuenta la racionalizacin del armado mediante el empleo de


mallas electrosoldadas realizadas a medida de dos tramos de 18 metros de encauzamiento en una
maana implica la colocacin de 3603.44 Kg repartidos de la siguiente manera:
18 paneles
de malla inferior zapata
521.82 Kg
18 paneles
de malla superior zapata
854.28 Kg
18 paneles
de malla alzado exterior
546.50 Kg
18 paneles
de malla espera exterior
166.68 Kg
18 paneles
de malla alzado interior
823.86 Kg
18 paneles
de malla espera interior
265.14 Kg
6 paneles
de malla refuerzo interior
290.28 Kg
6 paneles
de malla separador
134.88 Kg
Dado el rendimiento de colocacin de la malla de 240 Kg / persona / hora puede verse que son
necesarios 3 operarios para el montaje de la armadura.
3.2 Solucin en ferralla tradicion al

Medicin del armado:


Zapata: Armadura principal inferior: 73 barras de 3.24 m (145.70 Kg)
Armadura reparto inferior:
15 barras de 18.4 m (109.02 Kg)
Armadura principal superior: 91 barras de 3.48 m (281.21 Kg)
Armadura reparto superior: 12 barras de 18.4 m (136.01 Kg)
Alzado: Armadura principal interior: 91 barras de 3.12 m (252.12 Kg)
Armadura reparto interior:
16 barras de 18.5 m (182.34 Kg)
Armadura espera interior:
91 barras de 1.15 m (92.93 Kg)
Refuerzo alzado interior:
91 barras de 1.55 m (125.25 Kg)
Armadura principal exterior: 91 barras de 3.12 m (175.90 Kg)
Armadura reparto exterior:
16 barras de 18.4 m (116.29 Kg)
Armadura espera exterior:
91 barras de 1.05 m (58.86 Kg)
Utilizando ferralla tradicional se tiene que para cada tramo de 18 metros de encauzamiento son
necesarios 1675.63 Kg de armadura. Por lo que si se arman 36 metros de encauzamiento, se estn
colocando 3351.26 Kg de acero en 5 horas.
Como puede verse, el armado del muro mediante ferralla tradicional se consigue utilizando
aproximadamente un 7% menos de kilogramos de acero que en la solucin en malla. Teniendo en
cuenta que el rendimiento de colocacin de la ferralla tradicional est estimado en 80
Kg/persona/hora, se ve que son necesarios 9 operarios para el montaje.

Los autores, 1998; Edicions UPC, 1998.

407

Elementos Estructurales

Ejercicio III-12 Racionalizacin del armado II

Un edificio de 8 plantas est diseado con forjados de losa maciza de 16 x 28 metros. Conocidas las
cuantas de armadura que se deben disponer se pretende realizar una racionalizacin de armaduras a
fin de conseguir un aumento de los rendimientos de colocacin y una mejora de la calidad.
Datos: - hormign H-250
- acero B-500-S
- juntas de construccin cada 9 metros
- dimensiones mximas de los paneles de malla electrosoldada especial:
9 metros en la direccin longitudinal
2.45 metros en la direccin transversal.
- cuantas de armadura: armadura superior de la losa: 1.40 cm /m
armadura inferior de la losa: 2.50 cm /m.
Nota: un panel de malla especial tiene tanto en la direccin longitudinal como en la transversal unos
sobrelargos o patillas de unas dimensiones iguales a la longitud de solapo correspondiente por un
lado y de una longitud igual o sensiblemente igual a la trama por el otro.
2

L: longitud de las barras longitudinales


ai: sobrelargo longitudinal de longitud
igual o sensiblemente igual a la trama
ad: sobrelargo longitudinal de longitud
igual a la longitud de solapo
T: longitud de las barras transversales
bi: sobrelargo transversal de longitud
igual o sensiblemente igual a la trama
bd: sobrelargo longitudinal de longitud
igual a la longitud de solapo
Plantear una solucin en malla electrosoldada especial o hecha a medida como una alternativa a la
que se utiliza frecuentemente con malla electrosoldada estndar.

Los autores, 1998; Edicions UPC, 1998.

408

Hormign armado y pretensado. Ejercicios

Solucin

Se plantea una solucin en malla electrosoldada especial como alternativa a la malla estndar. El
empleo de malla especial permite la colocacin tcnicamente correcta de la armadura de la losa ya
que todas las mallas estn situadas en un mismo plano, incluso en las zonas de solapo.
1

Problemtica del empleo de malla electrosoldada estndar

La prctica habitual en el armado de losas, basada en el empleo de malla electrosoldada estndar,


realiza el solapo de las armaduras superponiendo unas mallas sobre las otras. De esta forma se crean
hasta cuatro capas de mallas en las zonas de solapo.
Los efectos de la creacin de estas cuatro capas de malla son:
Disminucin del canto til y, en consecuencia, reduccin de la capacidad resistente del
elemento estructural.

Creacin de un tamiz que no es ms que una barrera para el hormign. Se dificulta el


hormigonado y vibrado haciendo que aumente la probabilidad de un hormigonado defectuoso.
Determinacin de dimetros de barras y separaciones:
En la siguiente tabla se tienen los valores de las cuantas geomtricas de armadura para distintos
dimetros y separaciones de barras.

Los autores, 1998; Edicions UPC, 1998.

409

Elementos Estructurales

A (cm )
Cuantas de armadura (cm / m)
(mm)
Sep.=10 cm Sep.=15 cm Sep.=20 cm Sep.=25 cm
6
0.283
2.83
1.887
1.415
1.132
8
0.503
5.03
3.353
2.515
2.012
10
0.785
7.85
5.233
3.925
3.14
12
1.131
11.31
7.54
5.655
4.524
A partir de las cuantas de armadura se obtienen las siguientes disposiciones de armadura:
- armadura superior de la losa: f 6 cada 20 cm 1.415 cm 1.40 cm
f 8 cada 20 cm 2.515 cm 2.50 cm
f

Clculo de longitudes de solapo

Para el clculo de las longitudes de solapo se utiliza la expresin de la normativa espaola teniendo
en cuenta que ms del 50 % de las barras traccionadas se solapan en la misma seccin.
Longitud de solapo = a l = 1.4 l
f f 15 cm
l = m f 200
f f 15 cm
l = 1.4 m f 140
Se obtiene para las barras de dimetro 6 mm, situadas en posicin II, una longitud de solapo de 30
cm. Y para las barras de dimetro 8 mm, situadas en posicin I, una longitud de solapo de 30 cm.
b

bI

bII

yk

yk

Modulacin de los paneles

Se plantea una disposicin de paneles en la que las barras longitudinales de cada panel tienen la
misma direccin que la mayor dimensin de la losa.
Para determinar las dimensiones del panel que se debe emplear en el armado de la losa se utiliza la
siguiente ecuacin:
n A - (n - 1) S = L
T

donde: n es el nmero de paneles de malla electrosoldada que se debe disponer


A es la anchura del panel
S es la longitud de solapo de la barra correspondiente
L es la longitud del elemento estructural que se debe ocupar los paneles de malla.
T

Los autores, 1998; Edicions UPC, 1998.

410

Hormign armado y pretensado. Ejercicios

Dada la longitud de solapo, que coincide en las barras de 6 y 8 mm de dimetro debido a las
diferentes posiciones de hormigonado, y dadas las longitudes L =27.94 m (dimensin longitudinal
de la losa menos el recubrimiento a ambos lados) y L =15.94 m (dimensin transversal de la losa
menos el recubrimiento a ambos lados) se obtiene que deben disponerse paneles de 5.58 x 2.26
metros. Esta dimensin de los paneles da lugar a 5 paneles en direccin longitudinal y 8 paneles en
direccin transversal.
T

Se utiliza la siguiente designacin de paneles, teniendo en cuenta que la mayor dimensin del panel
se denomina longitudinal y que la menor dimensin se denomina transversal:
S x S f - f de L x T
L

donde: S : separacin entre barras longitudinales


S : separacin entre barras transversales
f : dimetro de las barras longitudinales
f : dimetro de las barras transversales
L: longitud de las barras longitudinales
T: longitud de las barras transversales.
As pues, para la solucin en malla electrosoldada especial se tienen los siguientes paneles:
Malla superior losa
20 x 20 f 6 6
de 5.53 x 2.26 m
L
T

L
T

Los autores, 1998; Edicions UPC, 1998.

411

Elementos Estructurales

25.43 Kg / panel
40 paneles/ tramo

Malla inferior losa


42.25 Kg / panel
40 paneles/ tramo

20 x 20 f 8 8

de

5.858 x 2.26 m

Gracias a la geometra de estos paneles de malla electrosoldada especial se lograr una colocacin
rpida de la armadura. El procedimiento de colocacin consiste en que una vez colocado el primer
panel, el sobrelargo corto del segundo panel, ya sea el transversal o el longitudinal, debe tocar la
ltima barra longitudinal o transversal del primer panel.

Los autores, 1998; Edicions UPC, 1998.

You might also like