Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Spek Alat

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 62

MODEL

DTR 8500
ELECTRICAL

Ratio Range
Auto-Ranging, 0.8000 to 1500.0:1
Accuracy*
Ratio <10 to 1: 0.2% of Reading

Ratio 10 to 1000 to 1: 0.1% of Reading

Ratio >1000 to 1: 0.2% of Reading


Excitation Signal
PT/VT Mode: 44Vrms maximum

CT Mode: 0 to 1A Auto Level, 0.1 to 5Vrms


Excitation Current Display
Range: 0 to 1000mA; Accuracy: 2% of Reading 2mA
Excitation Frequency
70Hz
Display
LCD Character, 20 x 2, large format, LED backlight, day/night visible
Measurement Method
In accordance with ANSI/IEEE C57.12.90
Power Source
Dual operation; rechargeable NiCD battery & 115/230V, 50/60Hz line supply.

DTR may be changed from 115/230V by internal switch at any time. Units available with factory presetting of 115 or 230V.
Batteries
12V, 5 x 2 NiCD packs, 1300mAH, Panasonic P-130SCR or equivalent
Battery Life
Up to 10 hrs continuous operation. May be used while recharging. Low battery LCD indication.
Charging Time
14 hrs typical, C/10 rate
Line Fuse
115V: 1.0A, 5 x 20mm, slow acting

230V: 0.5A, 5 x 20mm, slow acting


Displayed Measurements
Turns ratio; RMS excitation current; polarity
Displayed Messages
Incorrect lead connections; H/X reversal (accidental step-up misconnection);

Short (excess excitation current); Open circuits; Circuit continuity & low battery
MECHANICAL

Connections
Cannon XLR connectors and large color-coded industrial clips
Leads
15 ft, H x X color-coded, in carrying bag
Display
Dual line alpha-numeric 3.875 x 0.875" with contrast adjustment and backlight
Operating Temperature
32 to 122F (0 to 50C), 0 to 90% RH (without condensation)
Case
Heavy duty structural polypropylene (yellow)
Dimensions
13 x 12 x 6" (330 x 305 x 152mm)
Weight
14 lb (6.4kg)

Model Number
OC60D-*
OC90D-*
System Output
0 - 60kV
0 - 90kV
Meter Accuracy
2% of full scale
Dimensions (W x H x D)
16 x 13 x 15 in
30 x 12 x 17 in

(41 x 33 x 38 cm)
(76 x 30 x 43 cm)
Shipping Dimensions
24 x 19 x 21 in
30 x 20 x 20 in
(W x H x D)
(61 x 48 x 53 cm)
(76 x 51 x 51 cm)
Weight
NET
69lbs (31kg)
122lbs (55kg)

SHIPPING
74lbs (33.5kg)
190lbs (86kg)

Input Voltage &


* In the model number, designate 'A' for
Frequency
120V/60Hz input or 'B' for 230V/50 Hz input
Harmonized Tariff Code
9030.33.0040
Included Accessories
Input Chord (7.5ft/2.3m), Calibration Certificate,

Operations Manual

LTCA-10 technical specifications

physical
Dimensions: 21W x 17H x 9 D (53.0 cm x 43.0 cm x 24.0 cm)

input
100-240 Vac, 50/60 Hz

specifications
Weight: 33 lbs. (15.4 Kg)

power

resistance
1 micro-ohm 500 ohms

test
1 A, 5 A, and 10 A

reading range

currents

accuracy
1 19,999 micro-ohms: 0.5% reading, 1 count

resistance
three resistance reading channels,

20 999 milliohms: 1% reading, 1 count

channels
one dynamic resistance channel

1 500 ohms: 1.5% reading, 1 count

display
back-lit LCD screen (128 x 64 pixels)

test
60 Vdc max

viewable in bright sunlight and low-light levels

voltage

printer
built-in 4K wide thermal printer

ac current
clamp-on current sensor, 1 20 A

input

Windows-based software is included with purchase price

pc

software

100

internal test

data storage

stores up to 128 static resistance test records (48 tests per record) and 11

010

record storage
dynamic resistance test records

110

external
stores up to 999 test records on a USB flash drive (drive not included)

temperature
Operating: -10C to +50C (+15F to +122F)

Storage: -30C to +70C (-22F to +158F)

options
shipping case

cables
one 50' (15.2m) current cable set, three 50' (15.2m) resistance cable sets,

computer
one RS-232C port, one USB port, one USB
ground cable, USB cable, RS-232C cable, LTC cable, power cord, cable bag

interface

humidity

flash drive port

90% RH @ 40C (104F)

load tap changer


designed to meet IEC 61010 (1995), UL

non-condensing

contact
61010-a, and CAS-C22.2 standards

altitude
2,000 m (6,562 ft)

safety
designed to meet UL 61010A-1 and CAN/
to full safety specifications

CSA C22.2 No. 1010.1-92 standards

warranty
one year on parts and labor

NOTE : the above specifications are valid at nominal voltage and ambient temperature of +25C (+77F). Specifications are subject to change without notice.

Specifications

Range

Insulation resistance

Voltage measurement

500V
1000V
2500V
5000V

AC/DC V

Measuring

0.099.9M
0.099.9M
0.099.9M
0.099.9M
30600V

range
100999M
100999M
100999M
100999M

AC/DC

1.001.99G
1.009.99G
1.009.99G
(50/60Hz)

10.099.9G

10.099.9G

1001000G(1T)

Accuracy
5rdg3dgt
5rdg3dgt
5rdg3dgt
5rdg3dgt
2rdg3dgt

20(100Gor more)

Short Circuit Current

1.3mA approx.

Rated test Current


1mA to1.2mA

1mA to1.2mA
1mA to1.2mA
1mA to1.2mA

@0.5Mload
@1Mload
@2.5Mload
@5Mload

Open circuit voltage


500VDC+30
1000VDC+20
2500VDC+20
5000VDC+20

-0
-0
-0
-0
630 Counts

Maximum display

999 Counts(1000 counts only at 1000G)

Current consumption

About 1000mA(During measurement)

25mA approx.

Withstand Voltage

5320V AC for 5 seconds

Safety standard

IEC 61010-1 CAT.3 600V, pollution Degree 2

Power supply

DC12V : R148 pcs

Dimensions

205(L) 152(W) 94(D)mm

Weight

approx. 1.8kg

Accessories
LINE PROBE 7165
ALKALINE BATTERY SIZE C(LR148PCS)EARTH CORD 7166INSTRUCTION MANUAL

GUARD CORD 7164


HARD CASE : MODEL 9124
PICKEL TYPE PROD 8019

Measuring range

Best accuracy

Resolution

Resolution

DCV

400m/4/40/400/600V

(0.7%+3)

0.1mV

DCV: 10M100M

ACV

4/40/400/600V

(1.6%+9)

0.001V

ACV: 10M11M

DCA

40m/400mA

(2.2%+5)

0.01mA

ACA

40m/400mA

(2.8%+5)

0.01mA

Resistance

400/4k/40k/400k/4M/40M

(1.5%+5)

0.1

Capacitance

50n/500n/5/50/100F

(5.0%+10)

0.01nF

Frequency

5Hz100kHz

(0.5%+3)

Duty cycle

20%80%

(0.5%+5)

Continuity

Buzzer sounds at between 10 and 120 Open voltage: approx. 0.4V

Diode test

Open voltage: approx. 1.5V

Measuring method

- method

Display

4000 count

Range selection

Auto and manual ranges

Over display

"O.L" is displayed(except AC/DC 600V ranges)

Polarity

Automatic selection(only " - " is displayed)

Battery low warning

Battery(
) mark lights when the internal battery's power is below

approx. 2.4V

2 times / sec

Sampling rate

Operating temperature / humidity

540 / 531, 80%RH(Max)

-1050, below 70%RH No condensation

Storage temperature / humidity

Environmental condition

Altitude 2000m or below, pollution degree II

Power consumption

7mW at DCV

Continuous use time

About 150 hours at DCV

40400Hz

Bandwidth

Fuse / Battery

0.5A/250V 1.5kA 5.2x20mm / R6P x 2

Size / Mass

H176 x W104 x D46mm / 340g

Standard accessories included

Hand strap, Instruction manual

You might also like