CX One Setup Manual W463 E1 12
CX One Setup Manual W463 E1 12
CX One Setup Manual W463 E1 12
W463-E1-12
SYSMAC
CX-One
FA Integrated Tool Package
CXONE-AL@@C-V4/AL@@D-V4
CXONE-LT@@C-V4
SETUP MANUAL
OMRON, 2008
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or
by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of
OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is
constantly striving to improve its high-quality products, the information contained in this manual is subject to change without
notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility
for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in
this publication.
Trademarks
COMBICON is a registered trademark of PHOENIX CONTACT.
ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA.
Windows, Windows XP, Windows Vista, Windows 7, and Windows 8 are registered trademarks of Microsoft
Corporation in the USA and other countries.
Other company names and product names in this document are the trademarks or registered
trademarks of their respective companies.
SYSMAC
CX-One
FA Integrated Tool Package
CXONE-AL@@C-V4/AL@@D-V4
CXONE-LT@@C-V4
Setup Manual
Revised October 2013
iv
Notice:
OMRON products are manufactured for use according to proper procedures by a qualified operator
and only for the purposes described in this manual.
The following conventions are used to indicate and classify precautions in this manual. Always heed
the information provided with them. Failure to heed precautions can result in injury to people or damage to property.
!DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury. Additionally, there may be severe property damage.
!WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury. Additionally, there may be severe property damage.
!Caution
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury, or property damage.
Visual Aids
The following headings appear in the left column of the manual to help you locate different types of
information.
Note Indicates information of particular interest for efficient and convenient operation of the product.
1,2,3...
vi
TABLE OF CONTENTS
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
1
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv
SECTION 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1
Overview of CX-One. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2
1-3
1-4
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2
Installation and Uninstallation . . . . . . . . . . . . . . . . . . . . . . .
13
2-1
14
2-2
CX-One Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
SECTION 3
Application Upgrades Using Auto Updates . . . . . . . . . . . . .
37
3-1
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
3-2
38
3-3
43
Appendix
A
CX-One Lite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
49
vii
TABLE OF CONTENTS
viii
!WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section
in its entirety and be sure you understand the information provided in the section and
related sections before attempting any of the procedures or operations given.
ix
z WARRANTY
The warranty period for the Software is one year from the date of
purchase, unless otherwise specifically agreed.
If the User discovers defect of the Software (substantial non-conformity
with the manual), and return it to OMRON within the above warranty
period, OMRON will replace the Software without charge by offering
media or download from OMRONs website. And if the User discovers
defect of media which is attributable to OMRON and return it to OMRON
within the above warranty period, OMRON will replace defective media
without charge. If OMRON is unable to replace defective media or correct
the Software, the liability of OMRON and the Users remedy shall be
limited to the refund of the license fee paid to OMRON for the Software.
z LIMITATION OF
LIABILITY
z APPLICABLE
CONDITIONS
z CHANGE IN
SPECIFICATION
USER SHALL NOT USE THE SOFTWARE FOR THE PURPOSE THAT IS
NOT PROVIDED IN THE ATTACHED USER MANUAL.
The software specifications and accessories may be changed at any time
based on improvements and other reasons.
z EXTENT OF SERVICE
The license fee of the Software does not include service costs, such as dispatching technical staff.
z ERRORS AND
The information in this manual has been carefully checked and is believed to
be accurate; however, no responsibility is assumed for clerical, typographical,
or proofreading errors, or omissions.
OMISSIONS
xi
xii
PRECAUTIONS
This section provides general precautions for using the CX-One FA Integrated Tool Package.
The information contained in this section is important for the safe and reliable application of the CX-One FA
Integrated Tool Package. You must read this section and understand the information contained before attempting
to set up or operate the CX-One FA Integrated Tool Package.
1
2
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv
xiv
xiii
Intended Audience
Intended Audience
This manual is intended for the following personnel, who must also have
knowledge of electrical systems (an electrical engineer or the equivalent).
Personnel in charge of installing FA systems.
Personnel in charge of designing FA systems.
Personnel in charge of managing FA systems and facilities.
Safety Precautions
!Caution When performing any of the following operations, always check the network
address and node address of the other node (PLC) and the node address and
unit number of the mounted Unit (PLC CPU Bus Unit or Special I/O Unit) or
the node address of the Component (DeviceNet Master/Slave or CompoWay/F Slave), and be sure that these operations can be performed safely for
the current status of the node (Unit or Component):
Transferring parameter or program data to the other node
Changing the operating mode of the other node
Unexpected operation may result if parameter or program data is transferred
to the wrong node (DeviceNet Master/Slave or CompoWay/F Slave), the operating mode of the wrong node is changed, or the other node is not in a suitable status to receive the program or parameter data or the operating mode
change.
!Caution Particularly when changing the target PLC to any PLC other than the relay
PLC, check the node address and node number of the target PLC carefully
before executing the change.) Unexpected operation and injury may result if
the wrong PLC is set as the target PLC.
Changing the operating mode
Transferring or verifying user-set data link tables
Transferring or verifying routing tables
Performing I/O table operations (including transferring CPU Bus Unit or
Special I/O Unit parameters)
Note
Operations performed from the CX-Integrator are performed for the target
PLC, which is not necessarily the same as the relay PLC.
!Caution When transferring parameters that have been created or edited on the computer to actual Units (PLC CPU Bus Units or PLC Special I/O Units) or to
actual components (DeviceNet Masters/Slaves or CompoWay/F Slaves), or
when resetting Units mounted on other PLC nodes or components (DeviceNet
Masters/Slaves or CompoWay/F Slaves) connected via communications with
other PLC nodes, always check the identifying numbers of the actual Units or
Components (i.e., the unit numbers and unit addresses or node addresses)
before executing the transfer or reset. Unexpected operation and injury may
result if parameters are transferred to the wrong Unit or components, or the
wrong Unit or component is reset.
xiv
Safety Precautions
Observe the following precautions when using the CX-One.
When saving or opening a project file, always confirm the location of the
folder and the file name before executing the save or open. The CX-One
automatically switches the folder when saving and opening.
Before changing the operating mode, always confirm that doing so will not
adversely affect system operation.
Always check the operation of programs and parameters sufficiently
before using them for actual system operation.
Confirm that resetting CPU Bus Units, Special I/O Units, and DeviceNet
Master/Slave Units will not adversely affect system operation before
resetting these Units.
xv
Safety Precautions
xvi
SECTION 1
Overview
This section provides an overview of the CX-One FA Integrated Tool Package, its contents, and system requirements.
1-1
1-2
1-3
1-4
Overview of CX-One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1-1
1-1-2
CX-One Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2-1
1-2-2
User Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3-1
1-3-2
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4-1
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4-2
11
Section 1-1
Overview of CX-One
1-1
1-1-1
Overview of CX-One
The CX-One FA Integrated Tool Package
The CX-One FA Integrated Tool Package integrates all of the Support Software for OMRON PLCs and Components. Although previously it was necessary to purchase, install, run, and connect online to the PLC separately for the
Support Software for each Unit, the CX-One now provides an integrated
development environment based on the CPS (Component and Network Profile Sheet) for each OMRON Unit or Component. If the CX-One is installed in
a single computer, an integrated operating environment can be used all the
way from setting OMRON PLC Units through system startup and monitoring
to greatly increase system setup efficiency.
1-1-2
CX-One Features
Integrated Software
Management for OMRON
PLCs and Components
One computer with the CX-One installed provides the Support Software
required to handle any OMRON product.
All of the Support Software can be installed with a single license.
Files saved from the various Support Software can be centrally managed
in one location.
When Support Software is started from the I/O tables (i.e., the Unit Configuration Table registered in the PLC), PLC and Unit settings can be inherited so
that they do not have to be re-entered every time Support Software is started.
CPU Bus Units and Special I/O Units can be set without concern for
memory addresses and without relying on operation manuals. Parameter
names, selections, and setting ranges are automatically displayed.
Online, settings for virtual Units on the computer can be compared to the
settings in the actual Units, with any differences displayed in orange in the
comparison results.
The Unit configuration in I/O tables is displayed using Unit model numbers.
Model and unit version checks can be performed when transferring data
to actual Units.
Device types on the network can be confirmed using Unit models.
Note
Component and Network Profile Sheet (CPS) files contain CS/CJ-series Unit
definitions or Component definitions within the CX-One. CPS files are provided in XML format. The CX-One uses CPS files to recognize CS/CJ-series
Units. Settings for CPU Bus Units and Special I/O Units are also created
based on CPS files.
Section 1-2
1-2
1-2-1
Model
CXONE-AL@@CV4/AL@@D-V4
Ver. 9
CX-Integrator
Ver. 2
CX-Simulator
Ver. 1
CX-Designer
Ver. 3
CX-Motion
Ver. 2
CX-Motion-NCF
Ver. 1
CX-Motion-MCH
Ver. 2
CX-Position
Ver. 2
CX-Drive
Ver. 2
NV-Designer
Ver. 1
CX-Protocol
Ver. 1
CX-Process Tool
Ver. 5
Ver. 4
CX-FLnet
Ver. 1
Network Configurator
Ver. 3
CX-Server
Ver. 5
SwitchBox Utility
Ver. 1
Section 1-2
The contents of CX-One are listed in the following table. Please confirm that
you have received everything.
CXONE-AL@@C-V4/CXONE-AL@@D-V4 CX-One FA Integrated Tool
Package
Installation Disks (CXONE-AL@@C-V4: CD-ROM)
4 disks
1 disk
PDF manuals in
the CD-ROM or
DVD (Only the
main manuals are
listed.)
Note
Note
The license number required for installation is printed on the Software License
Agreement/User Registration Card. Place this card in a safe place and be
sure not to lose the license number.
1-2-2
Section 1-2
User Registration
Always perform user registration before using the CX-One.
1. The following Online Registration Dialog Box will be displayed after when
computer is restarted upon completion of CX-One installation.
2. Click the Register Button. A wizard will connect you to the OMRON CXOne website. (See note.)
Note
3. Enter the information required for user registration according to the site
windows. Use the product key and license number given on the Software
License Agreement/User Registration Card provided with the CX-One.
4. After completion of registration, registration confirmation will be sent to the
email address input during the registration procedure.
Note
The Online Registration Dialog Box will be displayed even if online registration has already been completed. If this happen, select the Do not display this
dialog again option and click the Exit Button. Also use this procedure in the
following cases.
The Windows login name is different from the registered name.
User registration was performed using the User Registration Postcard.
Note
Do not register more than once. For example, if you're returned the card, do
not register online.
Note
Approximately two weeks will be required from the time the User Registration
Postcard is posted until confirmation of registration is returned to you. Downloading OMRON Standard Libraries and other operations allowed only for
registered users will not be possible during this period.
Section 1-3
1-3
1-3-1
Support Software
in CX-One
CX-Programmer
CX-Integrator
CX-Protocol
CX-Simulator
CX-Position
CX-Motion-NCF
CX-Motion-MCH
CX-Motion
CX-Drive
Outline
Documentation
(PDF manuals provided
in CD-ROM)
Started from a PLC in the CX-Programmer OperaApplication software to create and debug
tion Manual
CX-Integrator Network
programs for SYSMAC CS/CJ/CP/NSJ(Cat. No. W446)
series, C-series, and CVM1/C-series CPU Configuration Window.
CX-Programmer OperaUnits, and to create and monitor data for
tion Manual: Function
SYSMAC CS/CJ-series Position Control
Blocks and Structured Text
Units (High-speed Type only).
(Cat. No. W447)
CX-Programmer Operation Manual: SFC
(Cat. No. W469)
CX-Integrator Operation
Application software to build and set up FA Started by selecting
Manual (Cat. No. W464)
Tools - Network Setnetworks, such as Controller Link,
tings from the CX-ProDeviceNet, CompoNet, CompoWay, and
grammer menu bar or
Ethernet networks. The Routing Table
Component and Data Link Component can from a CPU Unit in the
be started from here. DeviceNet Configura- CX-Programmer I/O
tables.
tion functionality is also included.
Utility software that helps you to debug
Started from the CX-Pro- Online Help
PLCs. It helps you to monitor the I/O status grammer Tools Menu.
and to monitor/change present values
within the PLC you specify.
Started from a Serial
CX-Protocol Operation
Application software to create protocols
Communications Board
Manual (Cat. No. W344)
(communications sequences) between
or Unit in the CX-ProSYSMAC CS/CJ/CP/NSJ-series or
grammer I/O tables.
C200HX/HG/HE Serial Communications
Boards/Units and general-purpose external
devices.
Application software to simulate SYSMAC --CX-Simulator Operation
CS/CJ/CP/NSJ-series CPU Unit operation
Manual (Cat. No. W366)
on the computer to debug PLC programs
without a CPU Unit.
Application software to create and monitor
data for SYSMAC CS/CJ-series Position
Control Units (except for High-speed Type).
Application software to monitor and set
parameters for SYSMAC CS/CJ-series
Position Control Units and Servo Drivers
that support MECHATROLINK-II communications.
Application software to create data for SYSMAC CS/CJ-series MCH Units, create
motion programs, and perform monitoring.
CX-Position Operation
Manual (Cat. No. W433)
CX-Motion-NCF Operation Manual (Cat. No.
W436)
Section 1-3
Outline
CX-Designer
NV-Designer
CX-Configurator
FDT
Documentation
(PDF manuals provided
in CD-ROM)
Started from a Loop Con- CX-Process Tool Operatroller in the CX-Program- tion Manual (Cat. No.
mer I/O tables.
W372)
Started by selecting Execute - Create Tag File Start NSFP from the CXProcess Tool menu bar
(starts automatically after
execution of the CSV tag
compiler).
Started from a NS-series
PT in the CX-Integrator
Network Configuration
Window.
---
Online Help
---
---
---
Refer to documentation of
individual Support Software.
The following utilities are stored in the Utility folder on the DVD installation disk or on disk 4 of the CD-ROM
installation disks. Install any required utilities individually.
Utility
OMRON Automation
Software Remover
Location
\Utility\CXOneRemover
NT Support Software
\Utility\NT-SupportTool
Description
This utility removes files that are related to problems that can occur
during CX-One installation to allow you to re-install the CX-One. If
problems occur during CX-One installation, use this utility.
This utility is used to create screen data for NT-series Programmable
Terminals.
Section 1-3
1-3-2
CX-Programmer
CX-Integrator
CPU Rack
Ethernet Unit
(CS1W/CJ1W-ETN@@)
CX-Protocol
CX-Position
CX-Motion-NCF
CX-Process Tool
Faceplate
Auto-Builder for NS
Network Configurator
CX-FLnet
NS-series PC (-V1)
Start with Settings
Inherited
CX-Designer
Select CX-Integrator.
NT Link
E5@@ Temperature
Controller
CompoWay/F
Started with
Settings Inherited
Started with
Settings Inherited
Routing Table
Component
Data Link
Component
Section 1-4
System Requirements
Starting while Inheriting
Settings
Setting the device type is not required every time different Support Software is started.
The online connection is also inherited by the newly opened Support Software.
New project files are automatically created for the newly opened Support
Software.
1-4
1-4-1
System Requirements
System Requirements
The system requirements for the CX-One are given in the following table.
Item
Operating system
(OS) (See note 1.)
Requirement
Microsoft Windows XP (Service Pack 3 or higher)
Microsoft Windows Vista (See note 4.)
Microsoft Windows 7 (See note 4.)
Microsoft Windows 8 (See notes 4 and 5.)
Computer
Computer with a processor recommended by Microsoft.
Memory
Memory capacity recommended by Microsoft.
Hard disk
Approx. 4.0 GB or more available space is required to install
the complete CX-One package.
Display
XGA (1024 x 768), High Color (16 bit) or better
Disk drive
DVD-ROM drive
Communications ports RS-232C port, USB port, or Ethernet port (see note 3.)
Other
Internet access is required for online user registration,
including a modem or other hardware connection method.
Note
Section 1-4
System Requirements
Restriction
If you use a new font (e.g., Meiryo) in a project on
Windows Vista or a newer OS, the font size on labels
may be bigger and the text may protrude from the
components if the project is transferred from CXDesigner running on Windows XP or an earlier OS to
the NS/NSJ.
CX-ProgramAlthough you can install CPS files, EDS files, Expanmer/CX-Integra- sion Modules, and Interface Modules, the virtual store
tor/Network
function of the OS imposes the following restrictions
Configurator
on the use of the software after installation. These
restrictions will not exist if application data is installed
using Run as Administrator.
If another user logs in, the applications data will
need to be installed again.
The CPS files will not be automatically updated.
CX-Server
Restrictions are imposed on the following functions.
The driver cannot be changed from the default setting if Controller Link is set as the network type in
the Change PLC dialog box.
Online connections will not be possible through
Controller Link Boards or SYSMAC LINK Boards.
Online connections using FinsGateway as the network type will not be possible from the CX-Programmer or CX-Integrator.
Communications will not be possible though a CS1
Board and PCI bus.
(5) The following restrictions exist if the CX-One is used on Microsoft Windows 8.
1) Start Menu Shortcuts
A Start Menu is not displayed on the Windows 8 desktop, so the
CX-One applications cannot be started from the Start Menu. If you
are using Windows 8, start the applications in CX-One from the
Start Screen.
2) Installing NET Framework 3.5 SP1
Some of the applications in CX-One require .NET Framework 3.5
SP1. If Windows 8 is not connected to the Internet, .NET Framework 3.5 SP1 cannot be installed. If necessary, connect to the Internet and install .NET Framework 3.5 SP1.
10
Section 1-4
System Requirements
1-4-2
Note
CX-Programmer
CX-Integrator
CX-Position
CX-Motion
CX-Motion-NCF
CX-Motion-MCH
CX-Drive
CX-Designer
NV-Designer
CX-Process Tool
Faceplate Auto-Builder for NS
CX-Protocol
CX-Simulator
CX-Thermo
CX-Flnet
Approx. 5 MB
Approx. 20 MB
Approx. 700 MB
Always installed.
(1) For CX-One installation, hard disk space (1.2 GB min.) is also required to
install .NET Framework in addition to the above hard disk space requirements.
(2) If the complete CX-One package is installed, approximately 4.0 GB of
hard disk space will be required. When installing software, work space for
installation is additionally required. Check available space on your hard
disk before installing software.
11
System Requirements
12
Section 1-4
SECTION 2
Installation and Uninstallation
This section describes how to install and uninstall the software provided in the CX-One.
2-1
2-2
14
2-1-1
14
2-1-2
14
CX-One Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
2-2-1
28
2-2-2
31
2-2-3
33
13
Section 2-1
2-1
2-1-1
Time Requirements
The CX-One FA Integrated Tool Package integrates all of the Support Software for OMRON PLCs and Components. If the complete CX-One package is
installed, between approximately 15 and 45 minutes will be required for installation depending on the performance of the computer.
Precautions for
Installation
2-1-2
1. Insert disk 1 of the CX-One installation disks (CD-ROM) into the CD-ROM
drive.
2. The setup program will start automatically and the Choose Setup Language Dialog Box will be displayed.
The language of the operating system running on the computer will be selected automatically.
If the above dialog box is not displayed, double-click the CD-ROM driver
from the Explorer to display it.
Select the language to be installed and then click the OK Button.
14
Section 2-1
When the OK Button is clicked, a splash window for the CX-One will be
displayed, followed by the Setup Wizard.
3. If the CX-Server is already installed on the computer, the following dialog
box will be displayed as a prompt to delete the older version of the CXServer.
Click the OK Button and uninstall the CX-Server. If the Cancel Button is
clicked, CX-One installation will be exited.
If an earlier version of any of the Support Software is already installed in
the computer, one of the following dialog boxes will be displayed.
15
Section 2-1
Dialog Box When an Earlier Version of the CX-Programmer Is Installed
Click the OK Button and uninstall the earlier version of the CX-Programmer. If the Cancel Button is clicked, CX-One installation will continue without uninstalling the earlier version of the CX-Programmer. This would
result in there being two versions of the CX-Programmer installed at the
same time, so we recommend always clicking the OK Button.
Dialog Box When an Earlier Version of Other Support Software Is
Installed
Click the OK Button and uninstall the earlier version of the Support Software. If the Cancel Button is clicked, CX-One installation will be canceled.
4. The CX-One Setup Wizard will be started. Click the Next Button.
16
Section 2-1
Read the license agreement completely and if you accept all of the terms,
select the I accept the terms of the license agreement Option and click the
Next Button.
6. The User Information Dialog Box will be displayed.
The default names registered in the computer will be entered for the user
name and company name. Enter the license number and click the Next
Button. The license number is given on the Software License/Registration
Card provided with the product.
17
Section 2-1
Select the region in which the software was purchased and click the Next
Button.
8. The Choose Destination Location Dialog Box will be displayed.
Select the destination location and click the Next Button. By default, the
CX-One will be installed in C:\Program Files\OMRON\CX-One\.
9. The Setup Type Dialog Box will be displayed.
18
Section 2-1
Select the Complete or Custom Option and click the Next Button.
Note
(1) CX-One installation will require approximately the same amount of time
(approximately 15 to 40 minutes) regardless of whether Complete or
Custom is selected. As a rule, select Complete and install the entire package at the same time provided that there is sufficient disk space available.
(2) CX-Configurator FDT will normally not be installed. Select Custom and
then select CX-Configurator FDT to install it.
The Select Features Dialog Box will be displayed if Custom was selected.
Note
19
Section 2-1
Note
@ CX-Integrator
@ CX-Designer
@ CX-Protocol
@ Network Configurator
@ CX-Configurator FDT
@ PLC Tools
10. If Complete was selected or if Custom was selected and the Smart FB Library feature was selected, the Choose Destination Location of the
OMRON FB Library Dialog Box will be displayed.
Check the destination location and click the Next Button. By default, the
Smart FB Library will be install in C:\Program Files\OMRON\CX-One\FBL\.
11. The Select Program Folder Dialog Box will be displayed.
20
Section 2-1
Specify the location to add a shortcut in the program folder of the Windows
Start Menu and click the Next Button.
12. The Ready to Install the Program Dialog Box will be displayed.
Click the Install Button. The Installer will start the installation.
To check the installation settings, click the Back Button. To cancel installation, click the Cancel Button.
Installing the OMRON USB Device Driver
The OMRON USB driver Installation Wizard is displayed during the installation.
13. Click the Next Button.
21
Section 2-1
After the USB device driver is installed, the following dialog box is displayed.
15. Click the Finish Button.
The USB device driver is installed and installation of the Sysmac Studio
continues.
22
Section 2-1
During the installation, a dialog box will prompt you to install the WinPCap
component of the communications middleware.
16. Click the OK Button.
23
Section 2-1
24
Section 2-1
The network card for a direct Ethernet connection is selected and installation continues.
23. The OMRON SYSMAC PLC/NS USB Device Driver Installer will be displayed. Click the Next Button.
24. The following message will be displayed. Click the Continue Anyway Button.
25
Section 2-1
25. The following dialog box will appear after the USB device driver has been
installed.
26
Section 2-1
27. The following dialog box will be displayed when the Installer completes the
installation.
Select the desired option and click the Finish Button. If the Yes, I want to
restart my computer now Option is selected, the computer will be restarted
and then the Readme file will be displayed.
Note (a) It may be necessary to restart Windows after finishing the installation. If required, restart Windows according to the messages
displayed by the Installer.
(b) Always read the Readme.txt file before using the CX-One.
27
Section 2-2
CX-One Maintenance
28. The Online Registration Dialog Box will be displayed when the Readme file
is closed.
A wizard will be started and will connect to the OMRON CX-One website
if the Register Button is clicked. (See notes a and b.)
Note (a) If the Exit Button is clicked to cancel registration, the Online Registration Dialog Box will be displayed every time CX-One Support
Software is started.
(b) Online installation will not be possible if the computer is not connected to the Internet. Enter the required information on the registration card and mail it in.
This completes installation of the CX-One.
Note
(1) Even if the previous versions for Support Software in the CX-One are uninstalled, the folders for the previous versions will remain in C:\Program
Files\OMRON. By default, the project files and other files that were created by the Support Software (e.g., .cxp project files for CX-Programmer)
will be in this directory. If this data is to be used by the CX-One, we recommended moving the files to suitable folders after installing CX-One.
(2) Any OMRON Support Software or Communications Middleware that is
not included in CX-One will remain installed on the hard disk even after
the CX-One is installed. This will not create any particular problems.
Examples:
DeviceNet Configurator (Support Software)
FinsGateway (Communications Middleware)
2-2
CX-One Maintenance
The following maintenance can be performed once the CX-One has been
installed.
1,2,3...
2-2-1
1. Insert disk 1 of the CX-One installation disks (CD-ROM) into the CD-ROM
drive.
2. The Choose Setup Language Dialog Box will be displayed and the language of the operating system running on the computer will be selected
automatically.
(If the following dialog box is not displayed, double-click the CD-ROM driver from the Explorer to display it.)
Select the language to be installed and then click the OK Button.
28
Section 2-2
CX-One Maintenance
3. A splash window for the CX-One will be displayed, and the installation
modification process will start.
4. The CX-One Maintenance Wizard will be displayed.
Select the Modify Option and click the Next Button.
29
Section 2-2
CX-One Maintenance
Select the features to be added.
Be sure that all features that are not to be deleted are selected.
Clear the selections for features to be removed.
The following applications cannot be re-installed individually with the maintenance functions.
CX-Integrator
CX-Designer
CX-Protocol
Network Configurator
Note
Any Support Software feature that is not selected here will be deleted from the
compute. Check the selections carefully.
Click the Next Button.
The CX-One installation will be modified according to the feature selections. Continue with the installation procedure according to the messages
displayed by the Installation Wizard.
6. If either of the following dialog boxes is displayed, replace the installation
disk (CD-ROM) as instructed by the message and click the OK Button.
This dialog box is not displayed if the software is being installed from a
DVD.
Alternatively:
30
Section 2-2
CX-One Maintenance
7. The following dialog box will be displayed when the Installer completes
modifying the installation. Click the Finish Button.
2-2-2
The CX-Server will not be deleted from the computer even if all CX-One Support Software is deleted. The CX-Server must be uninstalled separately to
delete it.
1,2,3...
31
CX-One Maintenance
Section 2-2
4. The CX-One Installation Wizard will be displayed. Select the Remove Option and click the Next Button.
5. The following dialog box will be displayed to confirm that all CX-One software is to be removed. Click the Yes Button to start the Uninstaller that will
delete the CX-One and then follow the messages in the dialog boxes to delete the CX-One.
6. When the uninstallation has been completed, the following dialog box will
be displayed. Click the Finish Button.
32
Section 2-2
CX-One Maintenance
2-2-3
(1) Do not uninstall the CX-Server if there are other programs on the computer that use it as the communications driver, e.g., the CX-Programmer.
If the CX-Server is uninstalled, it will no longer be possible to use these
other programs.
(2) Do not uninstall the CX-Server while other programs that use it as the
communications driver are running on the computer, e.g., the CX-Programmer. The CX-Server may not uninstall properly if other programs are
using it.
(3) When uninstalling all of the CX-Server software, always uninstall the CXServer Driver Management Tool before uninstalling the CX-Server. If the
CX-Server is uninstalled first, it may no longer be possible to uninstall the
CX-Server Driver Management Tool properly.
1,2,3...
33
Section 2-2
CX-One Maintenance
Select CX-Server Driver Management Tool from the dialog box and click
the Change/Remove Button.
2. A file deletion confirmation dialog box will be displayed. Click the Yes Button.
34
CX-One Maintenance
Section 2-2
5. In the same way, select CX-Server from the Add/Remove Programs Dialog
Box, click the Change/Remove Button, and uninstall the CX-Server by repeating steps 2 though 4.
6. Restart the computer when all programs have been uninstalled.
35
CX-One Maintenance
36
Section 2-2
SECTION 3
Application Upgrades Using Auto Updates
This section describes the CX-One auto update function.
3-1
Outline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1-1
3-2
3-3
38
Auto Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
38
3-2-1
Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
3-2-2
39
3-2-3
43
3-2-4
43
43
3-3-1
44
3-3-2
Update Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44
37
Section 3-1
Outline
3-1
3-1-1
Outline
Auto Update
The CX-One auto update function is a system for updating the Support Software included with the CX-One over the Internet. When the CX-One auto
update function is enabled, applicable updates for the CX-One Support Software are automatically found. The CX-One installed on the personal computer can be updated to the latest version by installing the updates that are
found.
The auto update function is automatically enabled when the CX-One is
installed.
The auto update function can be used for CX-One version 2.0 or higher.
3-2
3-2-1
Downloading updates may fail or the size of updates may become unknown if
a proxy server is used. Make the following settings if using a proxy server.
1. Select Start Settings Control Panel and double-click the Internet Options Icon.
2. Clear the selection of the Use HTTP1.1 through proxy connections Option
on the Advanced Tab Page.
Clear selection.
38
Section 3-2
3-2-2
3. A user authentication dialog will be displayed when using the auto update
service for the first time.
Enter the information listed below then click the OK Button.
The user authentication dialog will not be displayed for subsequent auto
updates once an update has been installed.
Item
Details
Email address
Enter the email address you registered after purchase.
License No. (16 digits) Enter the license number of the CX-One that you purchased.
Region
Select the region where the software was purchased.
Japan
Europe, Africa, Middle East
North America, South America
China
Taiwan
Korea
South-east Asia, India, the Pacific region
39
Section 3-2
If you have not registered, click click here to jump to the user registration website.
4. The OMRON Automation Software Upgrade Utility will be started and then
a list of installed applications will be displayed.
Click
Not deselectable
Note
40
Section 3-2
Click
Select
Click
Note
The updates that will be displayed will depend on the CX-One version and individual applications installed on the personal computer.
Click the Download only Button to save the update files to the computer
for later installation. For details, refer to Downloading Update Files for
Later Installation later in this section.
41
Section 3-2
7. Click the Install Button to download the selected updates. (If more than
one update has been selected, they will be downloaded one-by-one in the
order listed.)
When the updates have been downloaded, installation will start automatically.
8. When all installations have been completed, a message will be displayed
asking if you want to restart your computer.
Click the Yes Button to restart the computer now.
Click the No Button to restart the computer later.
1. In the list of possible updates in the OMRON Automation Software Upgrade Utility Dialog Box, select the updates to be downloaded and click the
Download Only Button.
Select
Click
Note
42
Section 3-3
Select the folder in which to save the update files and click the OK Button.
Downloading the update files will be started.
3. Once the update files have been downloaded, a message saying the
download has been completed will be displayed in the CX-One Upgrade
Utility Dialog Box.
4. Double-click the files downloaded to the computer to begin installation.
Follow the directions given by the Installer to install the update files.
Note
If any updates are not installed, they will be displayed again as applicable updates.
The update files can be deleted once they have been installed.
3-2-3
3-2-4
3-3
43
Section 3-3
3-3-1
Click
3. To enable periodic notification of auto updates, select the check boxes and
set the notification schedule. (To disable the periodic notification of auto
updates, clear the check boxes.)
4. Once the settings have been made, click the OK Button.
Set
Click
3-3-2
Update Notification
If periodic notification of auto updates is enabled, new updates will be
searched for at the first login after the set time has elapsed. The OMRON
Automation Software Upgrade Utility will be started if any applicable update is
found. There will be no notification, if no applicable updates are found.
44
Section 3-3
45
46
Section 3-3
Appendix A
CX-One Lite
CX-One Lite
CX-One Lite (CXONE-LT@@C-V@) is a software package that contains the software from the CX-One package
that is required for OMRON Micro PLC applications. This software provides support for the CP-series PLCs
and the CPM@@/SRM1 PLCs from the C Series.
Model
CXONE-LT@@C-V4
Ver. 9
Ver. 2
CX-Simulator
CX-Designer
NV-Designer
CX-Drive
CX-Thermo
Network Configurator
CX-Flnet
CX-Server and PLC Tools
SwitchBox
Ver. 1
Ver. 3
Ver. 1
Ver. 2
Ver. 4
Ver. 3
Ver. 1
Ver. 5
Ver. 1
CPU Unit
CP1H-XA40DR-A/XA-40DT-D/XA40DT1-D
CP1H- X40DR-A/X-40DT-D/X40DT1-D
CP1H-Y20DT-D
CP1L-M60D@-@/M40D@-@/M30D@-@
CP1L-L20D@-@/L14D@-@/L10D@-@
CP1L-EL@@@@-@/EM@@@@-@
CP1E-E@@D@-A
CP1E-N@@D@-@
47
Appendix A
CX-One Lite
C Series
Series
CPM2@
CPM2@-S@
CPM1/CPM1A
SRM1
CPU Unit
CPM2A-20CD/30CD/40CD/60CD
CPM2C-10CD/10C1D/20CD/20C1D/32CD
CPM2C-S100C/110C
CPM2C-S110C-DRT
CPM1(A)-10CDR/20CDR/30CDR/40CDR(-V1)
CPM1A-10CDT/20CDT/30CDT/40CDT(-V1)
CPM1A-10CDT1/20CDT1/30CDT1/40CDT1(-V1)
SRM1-C01/C02(-V1) (-V2)
System Requirements
System requirements to run CX-One Lite software are the same as those for the CX-One. Refer to 1-4-1 System Requirements for the system requirements for the CX-One.
Note
Remarks
Check boxes are provides so that
you can install only the required software.
(1) For CX-One installation, hard disk space (1.2 GB min.) is also required to install .NET Framework
in addition to the above hard disk space requirements.
(2) If the complete CX-One Lite package is installed, approximately 3.5 GB of hard disk space will be
required. When installing the software, work space for installation is additionally required. Be sure
you have sufficient available space before installing the software.
48
Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Revision code
The following table outlines the changes made to the manual during each revision. Page numbers refer to the
previous version.
Revision code
01
02
03
Date
July 2006
July 2007
August 2007
04
05
06
07
08
June 2008
February 2009
June 2009
December 2009
February 2010
09
10
11
12
May 2010
October 2010
April 2012
October 2013
Revised content
Original production
Made corrections accompanying upgrade of CX-One
Cover, inner cover, and pages 3 and 4: Made corrections to CX-One
model number suffixes.
Page 10: Modified the version from "CX-One Ver. 2.1" to "CX-One Ver 2.1 or
later."
Added upgraded information of CX-One Ver.3.0.
Added upgraded information of CX-One Ver. 3.1.
Added upgraded information of CX-One Ver. 3.2.
Added upgraded information of CX-One Ver. 4.0.
Added information and made minor corrections.
Added information and made minor corrections.
Added upgraded information of CX-One Ver. 4.1.
Revised Content Added Information and made minor corrections.
Made corrections for Windows 8 support.
Corrected mistakes.
49
Revision History
50
OMRON Corporation
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
1013