Technical Specification
ETHERNET
ZM401
IP69K Stainless Steel Enclosure
IBN Display USB
SERIAL
ZM405
IP69K Stainless Steel Enclosure
IBN Display
DESCRIPTION
These high performance, multi-function programmable indicators give you the flexibility
to adapt them for your applications.
Suitable for the office, dusty, wet or high pressure and heavy washdown environments,
the ZM400 series can display analyze, store, and transmit data across a range of
technology methods to meet your specific installation.
SPECIFICATIONS
GENERAL
Unit of Measure Four active choices (Pounds, Kilograms, Ounce, Gram, Pound/Ounce, Custom)
Capacity Selections 9,999,999 with decimal located zero to five places
Incremental Selections Multiples and sub-multiples of 1, 2, 5
Multi Range/Multi Interval Up to three independent weight ranges and divisions
Programmable Selections Zero range, motion detection, automatic zero tracking, eight point linearization
Time and Date Battery backed up time/date/year (12 hour AM/PM or 24 hour format)
Calibration Two to ten points
Analog to Digital Measurement Rate 100 Hz
Internal Resolution 53,687,100 counts per mV/V per second
Digital Filtering Harmonizer filtering with adaptable constant and threshold
Self Diagnostics Display, keys, inputs, outputs, serial port, scale A to D, USB port and option cards
Dynamic Weighing Minimum nominal weigh time 100 milliseconds, recommended minimum three hundred milliseconds
Programming Language Avery Weigh-Tronix Lua, GSE Macro
1
ZM400 SERIES Technical Specification
USER INTERFACE
Keypad ZM401 6 key and ZM405 24 key chemical resistant keypad with metal domed tactile feedback and audio
confirmation when pressed
Operational Keys ZM401: Zero, Print, Units, Tare, Select, and F1
ZM405: Zero, Print, Units, Tare, Sample, Setup, F1/ID, Scale, Target, Start, Stop, 0-9, Alpha, Decimal, Clear, and
common symbols
Status Annunciators Center of Zero, Motion, Battery status, Set point 1,2,3, Over/Under/Accept bar graph or fill bar graph, Preset Tare,
Active Ethernet connection. Additional annunciators are shown in the dot matrix display area
Display IBN illuminated: seven digit, nine segment display, green characters with black background 0.8” (20 mm) high digits
and Graphic Array used for Annunciators, mode identification and HMI (Human Machine Interface).
Sort bar/Checkweigher segments
Display Rate Selectable (1, 2, 5, 10, 20) times per second
Under/over/accept bar
or filling status bar
Motion/instability
Status Annunciators Battery status Set point Ethernet activity Custom Graphic Array
annunciators
PHYSICAL
Enclosures Stainless steel: 304 brushed stainless steel (IP69K certified) with GORE® Vent ventilation and tilt stand with provisions
for desk, wall and column mounting
Panel mount: Stainless steel panel mount IP66
Operating Temperature 14° F to 104° F / -10° C to 40° C (Compliance with legal for trade requirements)
-4° F to 140° F / -20° C to 60° C (Industrial)
10 to 90% humidity non condensing
Shipping Weight Stainless steel: 9 lb (4.1 kg)
Panel mount: 7 lb (3.2 kg)
Dimensions (L X W X H) Stainless steel: 9.6” x 5” x 8.8” (243 mm x 127 mm x 223 mm)
Panel mount: 8.7” x 3.4” x 6.9” (221 mm x 86 mm x 175 mm)
9.63
(244.6 mm) 3.55 8.69 3.49
8.25 (90.2 mm) (220.7 mm) (88.1 mm)
(209.6 mm)
(165.1 mm)
(176.3 mm)
(150.9 mm)
6.50
(222.3 mm)
6.94
5.94
8.75
8.43 5.0
(214.1 mm) (127.0 mm)
Stainless Steel
2
INPUT/OUTPUT
Remote Inputs Three TTL or voltage free logic level inputs can be received for basic key functions or application
program events
Standard Outputs Three outputs can be used for system variable setpoints or in combination with application program events
Serial Ports Two serial ports:
- Comm 1 RS232 full duplex Or - Comm 1 RS232 full duplex with handshaking
- Comm 2 RS232 full duplex - Comm 2 Not available
Manual and Autoprint function plus
programmable Input Interpreter
Supports SMA, ENQ and NCI command/response
protocols
Supports BSQ digital base
USB Host Printer
USB flash memory
Remote USB keyboard
Ethernet The Ethernet port can be configured to support five independent devices, it supports DHCP client/server and
Ethernet sockets plus it supports all the serial protocols
Fieldbus Ethernet/IP™ and Modbus TCP
ELECTRICAL
Power Requirements Line voltage: 90-264 VAC (110-240 VAC nominal), frequency 50 or 60 Hz, 12 to 36 VDC
Power consumption: estimated at 250mA at 12VDC for one 350 ohm weigh sensor and 600mA at 12VDC for fourteen
350 ohm weigh sensors.
Excitation 10 VDC(+/-5 VDC), short circuit protected
Supports up to sixteen 350 ohm weight sensors (two scales)
4 or 6 conductors with sense leads
Detachable plug connectors
Analog Signal Input Range -1 m/V/V to 5 mV/V
Analog Signal Sensitivity 0.1 µV/V/divisions minimum
0.5 µV/V/divisions recommended
Circuitry Protection RFI, EMI and ESD protection (10 V/M minimum RFI noise immunity)
OPTIONS
Option Kits Analog output kit: 0-5 VDC, 0-10 VDC and 4-20 mA* a
DeviceNet™ kit*
* = choose one for internal Profibus® kit*
Current loop kit: Current loop and RS485/RS422* a
a= choose up to two per USB device kit: Provides USB interface to PC* a
option expansion RS232 Wireless (Ethernet) internal kit: 802.11b/g wireless data communications kit with antenna*
Internal 120 VAC Relay module for IP69K model*
Scale Input 5 VDC excitation kit*
Scale Input 10 VDC excitation with STVS kit*
External I/O interface kit* a
DC Output, 4 relays 3-60VDC at 2A Kit* a
DC Input, 4 Inputs 4-30VDC kit* a
AC Output, 4 relays 20-240VAC at 1A kit* (IP69K models) a
AC Input, 4 Inputs 120-240VAC kit* (IP69K models) a
Severe Transient Voltage Suppressor (STVS)
3
ZM400 SERIES Technical Specification
www.averyweigh-tronix.com
Avery Weigh-Tronix is an ITW company
Intel and Intel Core are trademarks of Intel Corporation in the U.S. and/or other countries
Avery Weigh-Tronix is a trademark of the Illinois Tool Works group of companies whose ultimate parent company is Illinois Tool Works Inc (“Illinois Tool
Works”). Copyright © 2016 Illinois Tool Works. All rights reserved. This publication is issued to provide outline information only and may not be regarded
as a representation relating to the products or services concerned. This publication was correct at the time of going to print, however Avery Weigh-Tronix zm400series_spec_501391.indd
reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time. V5 AWT35-501391
4