STD720 Spec
STD720 Spec
STD720 Spec
Technical Information
Introduction
Performance Specifications
Reference Accuracy (conformance to +/-3 Sigma)
Table 1
Reference
Maximum Stability Accuracy1,2
Model URL LRL Min Span Turndown (% URL/Year (% Span)
Ratio for 10 years) Standard/
optional
STD720 400 in H2O (1000 mbar) -400 in H2O (-1000 mbar) 4 in H2O (10 mbar) 100:1 0.020
STD730 100 psi (7.0 bar) -100 psi (-7.0 bar) 1 psi (0.07 bar) 100:1 0.020 0.05 / 0.04
STD770 3000 psi (210 bar) -100 psi (-7.0 bar) 30 psi (2.1bar) 100:1 0.020
Zero and span may be set anywhere within the listed (URL/LRL) range limits
100 psi
STD730 4:1 0.005 0.045 25 (1.75) 0.100 0.010
(7.0 bar)
0.065 0.010
3000 psi
STD740 10:1 300 (21)
(210 bar)
400 in H2O
STD720 16:1 25 (62.5) 0.050 0.020
(1000 mbar)
Accuracy
option
High
100 psi
STD730 4:1 0.005 0.035 25 (1.75) 0.100 0.010
(7.0 bar)
0.065 0.010
3000 psi
STD740 10:1 300 (21)
(210 bar)
Turn Down Effect Temp Effect Static Effect
Total Performance = +/- √(Accuracy)2 + (Temp Effect)2+ (Static Line Pressure Effect)2
Total Performance Examples (for comparison): standard accuracy, 5:1 Turndown, up to 50 oF shift & up to 1000 psi
Static Pressure
STD720 @ 80” H2O: 0.218% of span
STD730 @ 20 psi: 0.199 % of span
STD770 @ 600 psi: 0.196 % of span
Typical Calibration Frequency:
Calibration verification is recommended every two (2) years
Notes:
1. Terminal Based Accuracy – Includes combined effects of linearity, hysteresis and repeatability. Analog output adds 0.005% of span
2. For zero based spans and reference conditions of: 25oC (77oF), 0 psig static pressure, 10 to 55% RH and 316SS barrier diaphragm.
4 STD700 Smart Pressure Transmitter
Supply Voltage 10.8 to 42.4 Vdc at terminals (IS versions limited to 30 Vdc)
Load Resistance 0 to 1,440 ohms (as shown in Figure 2)
Maximum Allowable
Working Pressure (MAWP)4,5
(ST 700 products are rated to
Maximum Allowable Working 4,500 psi (310 bar)
Pressure. MAWP depends on
Approval Agency and transmitter
materials of construction.)
1
LCD Display operating temperature -20°C to +70°C Storage temperature -30°C to 80°C.
2
Silicone 704 minimum temperature rating is 0oC (32oF). NEOBEE® M-20 minimum temperature rating is -15oC (5oF)”.
For STD720 at temperatures below -15oC URL is reduced to 100” H2O. NEOBEE is a registered trademark of Stepan Company
3
Short term equals 2 hours at 70°C (158°F)
4
MAWP applies for temperatures -40 to 125°C. Static Pressure Limit is de-rated to 3,000 psi for -26°C to -40°C. for all models. Use of
graphite o-rings de-rates transmitter to 3,625 psi. Use of 1/2:” process adaptors with graphite o-rings de-rates transmitter to 3,000 psi.
5
Consult factory for MAWP of ST 700 transmitters with CRN approval.
Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter Description
Barrier Diaphragms Material 316L SS, Hastelloy® C-2762, Monel® 400 3, Tantalum
Process Head Material 316 SS4, Carbon Steel (Zinc-plated) 5, Hastelloy C-2766
Vent/Drain Valves & Plugs 1 316 SS4, Hastelloy C-2762
Head Gaskets Glass-filled PTFE standard. Viton® and graphite are optional.
Carbon Steel (Zinc plated) standard. Options include 316 SS, NACE A286 SS bolts,
Meter Body Bolting
Monel K500, Super Duplex and B7M.
Adapter Flange materials include 316 SS, Hastelloy C-276 and Monel 400. Bolt
Optional Adapter Flange and
material for flanges is dependent on process head bolts material chosen. Standard
Bolts
adaptor seal material is glass-filled PTFE. Viton and graphite are optional.
Mounting Bracket 2” Pipe, Carbon Steel (Zinc-plated) or 304 Stainless Steel or 316 Stainless Steel
Fill Fluid Silicone 200 , CTFE, NEOBEE M-20 or Silicone 704
Pure Polyester Powder Coated Low Copper (<0.4%)-Aluminum. Meets NEMA 4X,
Electronic Housing
IP66, & IP67. All stainless steel housing is optional.
Can be mounted in virtually any position using the standard mounting bracket. Bracket
Mounting
is designed to mount on 2-inch (50 mm) vertical or horizontal pipe. See Figure 3.
Process Connections 1/4- NPT or 1/2- NPT with adapter (meets DIN requirements)
Wiring Accepts up to 16 AWG (1.5 mm diameter).
Dimensions See Figure 4.
Net Weight 8.3 pounds (3.8 Kg) with Aluminum Housing.
1 2
Vent/Drains are sealed with Teflon® Hastelloy C-276 or UNS N10276
3 4
Monel 400 or UNS N04400 Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316 stainless steel wetted
Process Heads.
6
Hastelloy C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy C-276
6 STD700 Smart Pressure Transmitter
HART Protocol
Software Download
Version: Utilizes Class-3 of the Common Software Download
HART 7 procedure as per FF-883 which allows the field devices of any
Power Supply manufacturer to receive software upgrades from any host.
Voltage: 10.8 to 42.4Vdc at terminals Honeywell Digitally Enhanced (DE)
Load: Maximum 1440 ohms See Figure 2 DE is a Honeywell proprietary protocol which provides digital
Minimum Load: 0 ohms. (For handheld communications a communications between Honeywell DE enabled field
minimum load of 250 ohms is required) devices and Hosts.
Foundation Fieldbus (FF) Power Supply
Power Supply Requirements Voltage: 10.8 to 42.4Vdc at terminals
Voltage: 9.0 to 32.0Vdc at terminals Load: Maximum 1440 ohms See figure 2
Steady State Current: 17.6mAdc Standard Diagnostics
Software Download Current: 27.4mAdc ST 700 top level diagnostics are reported as either critical
Available Function Blocks or non-critical and readable via the DD/DTM tools or
Block Type Qty Execution Time integral display as shown below.
Critical Diagnostics
Resource 1 n/a HART DD/DTM Tools Basic Display Simple Display
Transducer 1 n/a Electronic Module Electronics module fault Fault Comm El
DAC Failure
Diagnostic 1 n/a
Meter Body NVM Meter Body fault Fault Mtrbody
Analog Input 1* 30 ms Corrupt
Config. Data Corrupt Electronics module fault Fault Comm El
PID w/Autotune 1 45 ms
Electronic Module Electronics module fault Fault Comm El
Integrator 1 30 ms Diag Failure
Meter Body Critical Meter Body fault Fault Mtrbody
Signal Char (SC) 1 30 ms Failure
LCD Display 1 n/a Sensor Comms Meter Body Comm fault Fault Mbd Com
Timeout
Flow Block 1 30 ms
Non-Critical Diagnostics
Input Selector 1 30 ms
HART DD/DTM Tools
Arithmetic 1 30 ms Display Failure
* AI block may have two (2) additional instantiations. Electronic Module Comm Failure
All available function blocks adhere to FOUNDATION Meter Body Excess Correct
Fieldbus standards. PID blocks support ideal & robust PID Sensor Over Temperature
algorithms with full implementation of Auto-tuning. Fixed Current Mode
Scheduler and take over when the host is disconnected. No DAC Compensation
LRV Set Error – Zero Config. Button
Acting as a LAS, the device ensures scheduled data
URV Set Error – Zero Config. Button
transfers typically used for the regular, cyclic transfer of
AO Out of Range
control loop data between devices on the Fieldbus.
Loop Current Noise
Number of Devices/Segment
Meter Body Unreliable Comm
Entity IS model: 6 devices/segment
Tamper Alarm,
Schedule Entries No DAC Calibration
18 maximum schedule entries Sensor Supply Voltage Low
Number of VCR’s: 24 max Refer to ST 700 manuals for additional level diagnostic
Compliance Testing: Tested according to ITK 6.0.1 information
STD700 Smart Pressure Transmitter 7
Approval Certifications:
This certificate defines the certifications covered for the ST 800 Pressure Transmitter family of
products, including the SMV 800 Smart Multivariable Transmitter. It represents the compilation of
the five certificates Honeywell currently has covering the certification of these products into marine
applications.
Marine Certificates American Bureau of Shipping (ABS) - 2009 Steel Vessel Rules 1-1-4/3.7, 4-6-2/5.15, 4-8-3/13 &
13.5, 4-8-4/27.5.1, 4-9-7/13. Certificate number: 04-HS417416-PDA
Mounting Configurations
Figure 3 – Typical mounting configurations of STD720, STD730 & STD770 for reference only
Dimensions
Figure 4 – Typical mounting dimensions of STD720, STD730 & STD770 for reference only
Model Selection Guide
Model Selection Guides are subject to change and are inserted into the specifications as guidance only.
Model STD700
Differential Pressure Transmitter
Model Selection Guide:
34-ST-16-101 Issue 26
Instructions: Make selections from all Tables: Key through XIII using column below the proper arrow. Asterisk indicates
availability. Letter (a) refer to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.
KEY NUMBER URL LRL Max Span Min Span Units Selection Availability
400/(1000) -400/(-1000) 400/(1000) 4.0 (10) " H2O (mbar) STD720
a. Measurement
100 (7.0) -100 (-7.0) 100 (7.0) 1 (0.07) psi (bar) STD730
Range
3000 (210) -100 (-7.0) 3000 (210) 30 (2.1) psi (bar) STD770
1
Except Carbon Steel Heads shall use 316SS Vent/Drain, Plugs & Adapters w hen required
1 2 3
STD770
STD730
H L L H H 90o L STD720
TABLE III Agency Approvals (see data sheet for Approval Code Details)
No Approvals Required 0 * * *
FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof A * * *
CSA Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof B * * *
ATEX Explosion proof, Intrinsically Safe & Non-incendive C * * *
IECEx Explosion proof, Intrinsically Safe & Non-incendive D * * *
SAEx Explosion proof, Intrinsically Safe & Non-incendive E * * *
Approvals INMETRO Explosion proof, Intrinsically Safe & Non-incendive F * * *
NEPSI Explosion proof, Intrinsically Safe & Non-incendive G * * *
KOSHA Explosion proof, Intrinsically Safe & Non-incendive H * * *
EAC Customs Union (Russia,Belarus,Kazakhstan) Ex Approval Flame proof, Intrinsically Safe I * * *
ATEX/IECEx Explosion proof, Intrinsically Safe & Non-incendive 1 * * *
CCoE Explosion proof, Intrinsically Safe & Non-incendive J * * *
UATR Flameproof, Intrinsically Safe & Dustproof K * * *
TABLE VIII OTHER Certifications & Options: (String in sequence com m a delim ited (XX, XX, XX,….)
None - No additional options 00 * * *
NACE MR0175; MR0103; ISO15156 (FC33338) Process wetted parts only FG * * *
b
NACE MR0175; MR0103; ISO15156 (FC33339) Process wetted and non-wetted parts F7 c c c
Marine (DNV, ABS, BV, KR, LR) MT d d d
EN10204 Type 3.1 Material Traceability (FC33341) FX * * *
Certificate of Conformance (F3391) F3 * * *
b
Calibration Test Report & Certificate of Conformance (F3399) F1 * * *
Certifications & Certificate of Origin (F0195) F5 * * *
Warranty FMEDA (SIL 2/3) Certification (FC33337) FE j j j
Over-Pressure Leak Test Certificate (1.5X MAWP) (F3392) TP * * *
Cert Clean for O2 or CL2 service per ASTM G93 OX e e e
PMI Certification1 PM * * *
Extended Warranty Additional 1 year 01 * * *
Extended Warranty Additional 2 years 02 * * *
b
Extended Warranty Additional 3 years 03 * * *
Extended Warranty Additional 4 years 04 * * *
PRODUCT MANUALS
Description Part Number
Product Manual ST 700 Smart Transmitter User Manual - English 34-ST-25-44
Product Manual ST 700 Smart Transmitter HART/DE Communications Manual - English 34-ST-25-47
Product Manual ST 700 Smart Transmitter Safety Manual - English 34-ST-25-37
Product Manual ST 700 Smart Transmitter Foundation Fieldbus Manual - English 34-ST-25-48
Product Manual ST 700 Smart Transmitter Function Block Manual - English 34-ST-25-49
All product documentation is available at www.honeywellprocess.com.
Sales and Service
For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor,
contact one of the offices below.
Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033
South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015
Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, TX 77042