The Art SLA-2 Studio Linear Amplifier
The Art SLA-2 Studio Linear Amplifier
The Art SLA-2 Studio Linear Amplifier
Read instructions:
Retain these safety and operating instructions for future reference. Heed all warnings printed here and on the equipment.
Follow the operating instructions printed in this user guide.
Do not open:
There are no user serviceable parts inside. Refer any service work to qualified technical personnel only.
Power sources:
Connect the unit to mains power only of the type described in this user guide or marked on the rear panel. The power
source must provide a good ground connection.
Power cord:
Use the power cord with sealed mains plug appropriate for your local main supply as provided with the equipment. If the
provided plug does not fit into you outlet consult your service agent. Route the power cord so that it is not likely to be
walked on, stretched or pinched by items placed upon or against.
Grounding:
Do not defeat the grounding and polarization means of the power cord plug. Do not remove or tamper with the ground
connection on the power cord.
Ventilation:
Do not obstruct the ventilation slots or position the unit where the air required for ventilation is impeded. If the unit is to be
operated in a rack, case or other furniture ensure that it is constructed to allow adequate ventilation.
Moisture:
To reduce the risk of fire or electrical shock do not expose the unit to rain, moisture or use in damp or wet conditions. Do
not place container of liquid on it, which may spill into any openings.
Heat:
Do not locate the unit in a place close to excessive heat or direct sunlight, as this could be a fire hazard. Locate the unit
away from any equipment, which produces heat such as: power supplies, power amplifiers and heaters.
Environment:
Protect from excessive dirt, dust, heat, and vibration when operating and storing. Avoid tobacco ash, drink spillage and
smoke, especially that associated with smoke machines.
Handling:
To prevent damage to the controls and cosmetics avoid rough handling and excessive vibration. Protect the controls from
damage during transit. Use adequate padding if you need to ship the unit. To avoid injury to yourself or damage to the
equipment take care when lifting, moving or carrying the unit.
Servicing:
Switch off the equipment and unplug the power cord immediately if it is exposed to moisture, spilled liquid, objects fallen
into opening, the power cord or plug becomes damaged during a lightning storm or if smoke odor or noise is noted. Refer
servicing to qualified technical personnel only.
Installation:
Install the unit in accordance with the instruction printed in the user guide.
SAFETY PRECAUTIONS
Warning: For optimum performance and reliability, do not operate the
amplifier with a speaker load of less than 4 Ohms per channel, or any
combination of speakers that together are less than 4 Ohms.
Using one speaker per channel, it must be rated at 4 or more Ohms.
Using two speakers per channel, they must each be rated at 8 Ohms,
or greater. When in bridge mode, the speaker should be rated at 8
Ohms, or greater.
___________________
Purchased from
___________________
INTRODUCTION
Thank you for purchasing an ART SLA-2 Studio Linear Amplifier - and
congratulations, you now own one of the most versatile amplifiers available.
Offering a superb level of sound quality, the SLA-2s clean and powerful
circuitry combined with a straightforward user interface quickly and easily
delivers the power you need for professional and project studio monitoring.
FEATURES:
Extremely low noise, discrete linear design
200 Watts/Channel @ 8 Ohms
560 Watts/Bridged Mono @ 8 Ohms
Toroidal transformer
10 Hz to 40 kHz within 1dB
XLR, Euroblock & Inputs
Thermal dependent cooling system
Multi-way binding post outputs
Low profile 1U rack-mountable design
All steel chassis
Optional tamper-proof front panel security cover included
Perfect for professional and project studios, and commercial
installations
INSTALLATION
The SLA-2 may be used in a wide variety of project and professional
studio environments. Self-contained in a steel and aluminum
enclosure, the unit is designed for many years of use. For greater
reliability, we recommend that you not place the unit directly under or
on top of other sources of heat. It is important that any rack-mountable
unit is properly ventilated, and the SLA-2 is no exception.
AC POWER HOOKUP
The SLA-2 has an internal power supply designed to operate at 120
VAC @ 50 to 60 Hz. Units manufactured for use outside of North
America have been modified to comply with the required electrical
specifications.
AUDIO CONNECTIONS
Audio connections to and from the SLA-2 are balanced XLR [Pin 2 =
Hot (+), Pin 3 = Cold (-), Pin 1 = (Ground)] and balanced or
unbalanced [Tip = Hot (+), Ring = Cold (-), Sleeve = (Ground)].
EuroBlock connections: can be wired balance or unbalanced.
See diagram on page 10
SECURITY COVER
For commercial installations it may be desirable to set the gain controls on
the power amp, and then make them inaccessible to non-qualified operators.
This can be accomplished by using the Security Cover Plate which is included
with the SLA-2.
Simply set the channel attenuators to the desired gain settings, then press the
knobs into the chassis until they lock in their recessed position. Then remove
the two small phillips head screws, one on each side of the two channel
attenuator knobs. Use these same screws to attach the security cover plate to
the front panel, thereby covering the two channel attenuators, making them
tamperproof.
See diagram below
-Ch2_
-Ch1_ +
Spade Connector Loosen the red and black caps on the binding
posts (dont completely remove). Insert the spade connector into the
binding post and tighten the caps down on the spade connector. Be
sure that the wire connected to one post does NOT come in contact
with that of another post.
Banana Plug Insert the banana plugs into the caps of the binding
posts. Be sure that the red and black caps on the binding posts are
tightened down completely and that they are securely connected to
avoid the possibility of the banana plugs from popping out.
SMARTFAN
The SLA-2 features SmartFan, an advanced, thermal dependent fan
assisted convection cooled system. The SmartFan system is
dependent upon the internal ambient temperature inside the unit, and
runs at two different levels. The SmartFan system is extremely quiet.
Do not block the fan or constrict air circulation. Doing so may cause
the amp to overheat and/or shutdown.
FUSE
The SLA-2 utilizes a (T10A 250v 20mm) 10 Amp fuse. Be sure to
replace any blown fuses with a fuse of equal rating only.
AC POWER INPUT
The SLA-2 features an internal power supply. Plug the detachable
cable into a standard wall outlet. Be sure that the supplied voltage
matches that of the required voltage labeled on your amplifier. Never
plug the amp into an outlet that does not match the required voltage of
your amplifier. Serious damage could result.
11
OPERATION
The main application of the SLA-2 is as a studio linear power amplifier
for powering monitors. Connect source material directly into the inputs
and set the output controls to provide an appropriate level into the next
stage of your system (and an excellent choice for this are the ART
SLM-1 Studio Linear Monitors).
NORMAL OPERATION
For a typical stereo setup, connect the source (mixer, eq, etc.) outputs
into channels one and two of the amplifier. Connect your speakers to
the outputs on the rear of the amplifier. Be sure that your front gain
controls are turned down to their lowest level (full counter-clockwise).
Turn the amp on, then slowly turn the input level up. Use the front gain
controls to regulate the output volume. Be sure not to raise the volume
past the clip level; however, an intermittent clip signal is acceptable.
12
PROTECTION
The SLA-2s output circuitry is fully protected from short circuits. An
ultrasonic network decouples RF from the output and helps keep the
amplifier stable with reactive loads.
The SLA-2s heatsinks do most of the work in getting heat away from
the amplifier, in normal studio operation. A very quiet, rear mounted
variable-speed fan provides extra cooling of the amplifiers internal
circuitry as needed. If, in the unlikely event the heatsink should reach
194 degrees Fahrenheit, the amplifier will mute, until it cools down.
The SLA-2 is fully protected from shorts, opens, over-current, and
over-voltage. A relay disconnects the outputs under any fault
conditions and automatically returns to normal operation once the fault
is removed.
The amplifier is stable into loads as low as 2 ohms (stereo mode), and
4 ohms (bridged mono mode).
13
WARRANTY INFORMATION
Limited Warranty
Applied Research and Technology will provide warranty and service for this
unit in accordance with the following warrants:
Applied Research and Technology, (A R T) warrants to the original
purchaser that this product and the components thereof will be free from
defects in workmanship and materials for a period of three years from the
date of purchase. Applied Research and Technology will, without charge,
repair or replace, at its option, defective product or component parts upon
prepaid delivery to the factory service department or authorized service
center, accompanied by proof of purchase date in the form of a valid sales
receipt.
Exclusions:
This warranty does not apply in the event of misuse or abuse of the product
or as a result of unauthorized alterations or repairs. This warranty is void if
the serial number is altered, defaced, or removed.
A R T reserves the right to make changes in design or make additions to or
improvements upon this product without any obligation to install the same
on products previously manufactured.
A R T shall not be liable for any consequential damages, including without
limitation damages resulting from loss of use. Some states do not allow
limitations of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty gives you specific rights and
you may have other rights, which vary, from state to state.
For units purchased outside the United States, an authorized distributor of
Applied Research and Technology will provide service.
- 14 -
SERVICE
The following information is provided in the unlikely event that your unit
requires service.
1) Be sure that the unit is the cause of the problem. Check to make sure the
unit has the proper power supplied, all cables are connected correctly, and
the cables themselves are in working condition.
2) If you find the unit to be at fault, write down a complete description of the
problem, including how and when the problem occurs. Please write down a
description of your complete setup before calling Customer Service.
3) Contact our Customer Service Department at (716) 297-2920 for your
Return Authorization number or questions regarding technical assistance or
repairs. Customer Service hours are 9:00 AM to 5:00PM Eastern Time,
Monday through Friday.
4) Pack the unit in its original carton or a reasonable substitute. The packing
box is not recommended as a shipping carton. Put the packaged unit in
another box for shipping. Print the RA number clearly on the outside of the
shipping box. Print your return shipping address on the outside of the box.
5) Include with your unit: a return shipping address (we cannot ship to a
P.O. Box), a copy of your purchase receipt, a daytime phone number, and a
description of the problem.
6) Ship only your unit and its power supply (keep your manual!) to:
Applied Research and Technology, a Division of Yorkville Sound
4625 Witmer Industrial Estate
Niagara Falls, New York 14305
RA# ____________________
- 15 -
SLA-2 SPECIFICATIONS
Dimensions
Weight
Input Connections
Output Connections
Input Impedance
Input Sensitivity
Stereo Output Power, 8 ohms
Stereo Output Power, 4 ohms
Bridged Output Power, 8 ohms
Stable into:
CMRR
Frequency Response
Hum and Noise
Total Harmonic Distortion (THD)
Slew Rate
Damping Factor
Transformer Type
Power Requirements
ART maintains a policy of constant product improvement. ART reserves the right to
make changes in design or make additions to or improvements upon this product
without any obligation to install same on products previously manufactured. Therefore,
specifications are subject to change without notice.
Applied Research & Technology, a Division of Yorkville Sound
215 Tremont Street
Rochester, NY 14608 USA
(585) 436-2720
(585) 436-3942 (FAX)
www.artproaudio.com
2004 Applied Research & Technology
- 16 -