Specification
Input
Input Voltage
Input Frequency
Input Current
Output
Output Voltage
Output Voltage Trim
See tables
5% on 3.3 V & 5 V versions, 10% on
other single output models and V1 of
multi-output models. See note 1 for
ECM40/60 models
Initial Set Accuracy
1.0% V1, 5% V2, V3 & V4
Minimum Load
See tables
Start Up Delay
2 s max
Start Up Rise Time
50 ms
Hold Up Time
16/75 ms min at 115/230 VAC
Line Regulation
0.5%
Load Regulation
1% single output models;
3% V1, 5% V2 & V3 ECM40/60
multi-output models.
1% V1 & V2, 5% V3 & V4 ECM100
Cross Regulation
2% on ECM40/60 only
Over/Undershoot
None at turn on/off
Transient Response
4% max. deviation, recovery to within
1% in 500 s for a 25% load change
Ripple & Noise
1% pk-pk, 20 MHz bandwidth
Overvoltage Protection 115-135% Vnom, recycle input to reset
Overload Protection
110-150% on primary power limit,
auto recovery
Short Circuit Protection Trip and restart (Hiccup mode)
Temperature
0.05%/C
Coefficient
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature 0 C to +70 C. Refer to derating curves
for specific operating limitations.
Cooling
Convection & fan-cooled ratings
(see derating curves)
Operating Humidity
95% RH, non-condensing
Storage Temperature
-20 C to +85 C
Operating Altitude
3000 m
Shock
30 g pk, half sine, 6 axes
Vibration
2 g rms, 5 Hz to 500 kHz, 3 axes
Safety Approvals
Output 1
Max
Power
Voltage
+5.0
+7.0
+9.0
+12.0
+15.0
+18.0
+24.0
+33.0
+48.0
+5.0
+5.0
+5.0
+5.0
+5.0
+3.3
+5.0
40 W
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Output 2
Current
Min/Max(3)
0.0 A/8.0 A
0.0 A/5.7 A
0.0 A/4.4 A
0.0 A/3.5 A
0.0 A/2.7 A
0.0 A/2.2 A
0.0 A/1.7 A
0.0 A/1.2 A
0.0 A/0.9 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
Voltage
+12.0
+15.0
+12.0
+24.0
+15.0
+5.0
+3.3
Output 3
Current
Min/Max
V
V
V
V
V
V
V
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A/2.0
A/1.5
A/2.0
A/1.0
A/1.5
A/1.5
A/1.5
A
A
A
A
A
A
A
-12.0
-12.0
-15.0
+12.0
+12.0
Model
Number(2)
Current
Min/Max
Voltage
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
ECM40US05^
ECM40US07
ECM40US09^
ECM40US12^
ECM40US15^
ECM40US18
ECM40US24^
ECM40US33
ECM40US48^
ECM40UD21
ECM40UD22
ECM40UT31^
ECM40UT32
ECM40UT33^
ECM40UT34^
ECM40UT35
Notes
1. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed.
2. To receive unit with cover fitted, add suffix -C to model number. For Class I operation only.
3. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed 40 W.
Available from Farnell. See pages 204-206.
Mechanical Details
1.20
(30.5)
4.00 (101.6)
Input Connector J1
Pin 1
Line
Pin 2
Neutral
3.75 (95.25)
J1
2.00
(50.8)
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals
2
1
J2
1.75
(44.45)
Pin
1
2
3
4
5
6
V Adj.
4X 0.156 (3.96) mounting holes
0.312 (7.92) clearance top and bottom
0.14 (3.5)
SMD component height
Output Connector J2
Single
Multi
+V1
+V1
+V1
+V1
RTN
RTN
RTN
RTN
NC
-V3
NC
+V2
J2 mates with
Molex housing 43061-0006 &
Molex series 5194 crimp terminals
Weight: approx. 0.33 lb (150 g)
Notes
1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Cable harnessess with 300 mm wire available.
For single output models, order part number ECM40/60S LOOM.
For multi-output models, order part number ECM40/60DT LOOM.
Derating Curves
All ECM40 models with 5 CFM
100%
Output Power
Output Power
75%
50%
25%
0%
100%
75%
50%
25%
0%
10
20
50
60
30
40
Ambient Temp (C)
70
80
10
20
50
60
30
40
Ambient Temp (C)
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
70
80
AC-DC
ECM40
Output 1
Max
Power
Voltage
+5.0
+7.0
+9.0
+12.0
+15.0
+18.0
+20.0
+24.0
+33.0
+48.0
+5.0
+5.0
+5.0
+5.0
+5.0
+3.3
+5.0
60 W
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Output 2
Current
Min/Max(3)
0.0 A/12.00 A
0.0 A/8.60 A
0.0 A/6.70 A
0.0 A/5.00 A
0.0 A/4.00 A
0.0 A/3.30 A
0.0 A/3.00 A
0.0 A/2.50 A
0.0 A/1.80 A
0.0 A/1.25 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
Voltage
+12.0
+15.0
+12.0
+24.0
+15.0
+5.0
+3.3
Output 3
Current
Min/Max
V
V
V
V
V
V
V
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A/3.0
A/2.5
A/3.0
A/1.5
A/2.5
A/1.5
A/1.5
A
A
A
A
A
A
A
-12.0 V
-12.0 V
-15.0 V
+12.0 V
+12.0 V
Model
Number(2)
Current
Min/Max
Voltage
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
ECM60US05^
ECM60US07
ECM60US09^
ECM60US12^
ECM60US15^
ECM60US18
ECM60US20
ECM60US24^
ECM60US33
ECM60US48^
ECM60UD21
ECM60UD22
ECM60UT31^
ECM60UT32
ECM60UT33^
ECM60UT34^
ECM60UT35
Notes
1.
2.
3.
4.
Mechanical Details
Input Connector J1
Pin 1
Line
Pin 2
Neutral
1.20
(30.5)
4.00 (101.6)
3.75 (95.25)
J1
2.00
(50.8)
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals.
Optional ground (0.25 faston) tab
available, contact sales.
2
1
J2
1.75
(44.45)
Pin
1
2
3
4
5
6
Output Connector J2
Single
Multi
+V1
+V1
+V1
+V1
RTN
RTN
RTN
RTN
NC
-V3
NC
+V2
J2 mates with
Molex housing 43061-0006 &
Molex series 5194 crimp terminals.
V Adj.
4X 0.156 (3.96) mounting holes
0.312 (7.92) clearance top and bottom
0.14 (3.5)
SMD component height
Notes
1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Cable harnesses with 300 mm wire available.
For single output models, order part number ECM40/60S LOOM.
For multi-output models, order part number ECM40/60DT LOOM.
3. Mating connector kit available. Order part number ECM40/60 CONKIT.
Derating Curves
All ECM60 models convection-cooled
Output Power
100%
Output Power
AC-DC
ECM60
75%
50%
25%
0%
10
20
50
60
30
40
Ambient Temp (C)
70
80
100%
75%
50%
25%
0%
10
20
50
60
30
40
Ambient Temp (C)
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
70
80
AC-DC
ECM100
Output Current
Maximum
15.0 A
15.0 A
11.4 A
8.8 A
7.5 A
6.0 A
5.0 A
4.1 A
3.0 A
2.1 A
Minimum
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
Model
Number(1,3)
ECM100US03*^
ECM100US05*^
ECM100US07*
ECM100US09*
ECM100US12*^
ECM100US15*^
ECM100US18*
ECM100US24*^
ECM100US33*
ECM100US48*^
Output 1
Current
Voltage
Min/Max
+5.0 V
0.0 A/12.0 A
+5.0 V
0.0 A/12.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+3.3 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+3.3 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
Output 2
Current
Voltage
Min/Max
+12.0 V
0.0 A/3.0 A
+15.0 V
0.0 A/3.0 A
+12.0 V
0.0 A/3.0 A
+24.0 V
0.0 A/2.0 A
+15.0 V
0.0 A/3.0 A
+5.0 V
0.0 A/5.0 A
+3.3 V
0.0 A/5.0 A
+12.0 V
0.0 A/3.0 A
+15.0 V
0.0 A/3.0 A
+3.3 V
0.1 A/5.0 A
+5.0 V
0.1 A/5.0 A
+24.0 V
0.1 A/2.0 A
+24.0 V
0.1 A/2.0 A
+12.0 V
0.1 A/3.0 A
+15.0 V
0.1 A/3.0 A
Output 3
Current
Voltage
Min/Max
-12.0
-12.0
-15.0
+12.0
+12.0
-5.0
-5.0
+12.0
+12.0
+12.0
+15.0
-12.0
-15.0
V
V
V
V
V
V
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
Output 4
Current
Voltage
Min/Max
A
A
A
A
A
A
A
A
A
A
A
A
A
-12.0
-12.0
-12.0
-15.0
-5.0
-5.0
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
A
Model
Number(1,3)
ECM100UD21*
ECM100UD22*
ECM100UT31*^
ECM100UT32*
ECM100UT33*^
ECM100UT34*^
ECM100UT35*
ECM100UT36*
ECM100UT37*
ECM100UQ41*
ECM100UQ42*^
ECM100UQ43*^
ECM100UQ44*
ECM100UQ45*^
ECM100UQ46*
Notes
1. To receive unit with cover fitted, add suffix -C to model number.
2. Output 3 available with opposite polarity for OEM quantities.
3. * denotes ECM100 models are class I only, contact sales for class II.
Mechanical Details
Weight: approx.
0.4 lb (180g)
4.50 (114.3)
Input Connector J1
Pin 1
Line
Pin 2
Neutral
1.20 (30.5)
4.25 (107.95)
2.50
(63.5)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
J1
2.25
(57.15)
J2
12
V Adj.
0.14 [3.5]
SMD component height
Notes
1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Cable harnessess with 300 mm wire available. For single output models, order
part number ECM100S LOOM. For multi-outputs, p/n ECM100DT LOOM.
Derating Curves
3. Mating connector kit available for single output models. Order part number
ECM100S CONKIT.
4. Covers available. Order part number ECM100 COVER^.
5. Available in a 3 x 5 footprint for OEM quantities. Contact sales for details.
80
A
B
C
D
60
40
20
0
10
20
50
60
30
40
Ambient Temp (C)
70
80
US24-48
US12-18
US05
US03
Note:
1. Derate by 10% if cover is fitted.
2. For multi output convectioncooled operation above +50 C
derate linearly to 50% at +70 C.
100%
Output Power
Output Connector J2
Single
Multi
+V1
+V1
+V1
+V1
+V1
+V1
+V1
+V1
V1 RTN
RTN
V1 RTN
RTN
V1 RTN
RTN
V1 RTN
RTN
NOT USED
+V2
NOT USED
+V2
NOT USED
V3
NOT USED
-V4
75%
50%
25%
0%
10
20
50
60
30
40
Ambient Temp (C)
70
80
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
22-Oct-07