Purpose:
The purpose of this tutorial is to create a street lighting scene, demonstrating key
features of DIALux.
Street Specifications:
Luminaire Specifications:
1
Creating a new project
In this tutorial we will create a “street project”. To create a new project, follow the
subsequent steps:
Upon startup of DIALux, select New Street Project from the Welcome dialogue
screen.
Upon creation of the project, to ensure that you are using the “Imperial” system of
units, from the main toolbar select File →Settings →General Options and under
the Global tab, select the Imperial system for “Dimensions” and “Lighting” units.
Furthermore, the General Options menu can be used to modify different project
settings of the project such as, room dimensions, CAD window, output and
contact properties.
2
Figure 3 General Settings
Once you have created the project, you have the option to organize the global
project information, such as project name, contact/address information, and the
location under Project manager. To access the global information menu select
Project 1 from the tree structure under Projects menu.
3
In this tutorial we will build a street with the following specifications:
Note from the tree structure that upon creation of the project, Roadway 1 has
been added to the scene. By default a street only consists of one roadway with a
valuation field; the valuation field starts at the beginning of a street planning
(coordinate: (0, 0) ft).
4
calculation surface considers all luminaires and other objects inserted in the
exterior scene.
Selecting Street 1 from the tree structure enables the user to adjust the general
street settings. The user has the option to modify the street name, lighting
situation, maintenance method, and the street arrangement. The Lighting
Situation can be entered manually or by means of the built-in wizard; the wizard
assigns a lighting situation based on the type of vehicles (motorized vehicles,
slow vehicles and bicycles) used on the roads, the typical/permitted speed of the
vehicles, and whether the pedestrians are permitted on the road. By default your
project gets a lighting situation with the designation A1. In this tutorial, we will be
planning a Collector road type. Collector roads contain 4 or less lanes, with
sidewalks on both sides of the road; they connect the traffic from local roads or
sections of residential roads to the main roads, where motorized and slow
vehicles with a typical speed of < 60km/h and pedestrians are permitted on the
road. To comply with these requirements, the wizard was used to assign B2 as
our Lighting Situation; Figure 6 shows the step-by-step use of the wizard to
select the lighting situation.
5
Figure 6 Using the Wizard to assign a Lighting Situation
6
Figure 7 Street Scene - Lighting Situation
As depicted in Figure 5, by default the street has 2 lanes only; therefore we will
increase the number of lanes to 4 to meet our design requirements.
Under Project menu, from Project 1→ Street 1, select Roadway 1 and under
Project manager change the properties of the road as follows:
7
Figure 8 Roadway 1 - Properties
From Project manager’s Street Coating tab notice that upon selection of Tarmac
class (in our case R2), its corresponding tarmac coefficient q0 (in our case 0.070)
is automatically assigned. In addition, notice that by default the Uniformity
coating on wet roadways is assigned with the designation W3 (and its
corresponding coefficient of 0.200). Thus, as in this project Uniformity coating is
not one of design considerations, we will leave it at its default value.
Next, we will add sidewalks to both sides of the street. Under Project menu, from
Project 1, right-click on Street 1 and select Insert Street Element→ Sidewalk.
8
Figure 9 Inserting Sidewalks
Upon completion, notice that Sidewalk 1 has been added to the tree structure.
From Project 1→ Street 1, select Sidewalk 1 and modify its properties as follows:
9
Repeat the same procedure to add a second sidewalk, with the same
parameters, to the other side of the street. From the CAD Window notice that the
sidewalks have been added to the same side of the roadway.
10
Figure 12 Rearranging Street Elements
11
In the next step we will select the appropriate “illumination class” for each one of
the street elements. The Illuminance Class can be selected manually or by
means of the built-in wizard. Under Project menu, from Project 1→ Street 1→
Sidewalk 2, select Valuation Field Sidewalk 2, and under Project manager, select
S6 from the drop-down menu.
12
Figure 15 Roadway 1 & Sidewalk 1 Illuminance Class
Similarly, you can use the Insert Street Element feature to insert additional street
elements such as roadways, bicycle lane, emergency lane, lay-bys and grass-
strips to the project.
13
Adding Luminaires:
Note that DIALux refers to light fixtures as “luminaires”. Therefore, from here on
we will refer to LEDs (IES files) as luminaires.
In this section we will use the Luminaire Selection menu to insert luminaires into
our project. Using DIALux the user has the option to import luminaires from
different manufacturers’ website or to import his/her own IES files. For the
purpose of this tutorial, we will import the Street_Lighting.ies file from
Dialux_Data folder.
While DIALux running in the background, open the “Dialux_Data” folder. From
Dialux_Data →Vertical Marketing Strategy folder, right-click on the
“Street_Lighting.ies” file and select Insert into DIALux Project.
14
Figure 17 Inserting Street Arrangement
This will open the luminaire property window under Project manager. To comply
with the design specifications (see Table 1), we will change the luminaire
properties as follows:
Setting the Correction Factor to 1.00 implies that the luminaire is 100% efficient
(i.e. no losses), so 5500lm actually comes out of the luminaire.
15
Click Insert to confirm your selection.
We will follow the same procedure to insert luminaires to the bottom side of the
roadway with the following properties:
16
Figure 19 Luminaire Properties - Bottom
Remember that you always have the option to select your luminaires and modify
their properties under Project manager. The luminaires are added to the tree
structure as they are inserted into the project. In this example, based on the
spacing between the poles and the default length of the street, DIALux has
inserted 8 luminaires into the scene. Selecting Street Arrangement enables you
to change/modify physical properties (luminaire type, position, arrangement,
mounting height, etc…) of the luminaire. To change the technical properties (flux,
power, PF, filter, etc…) of your luminaires select the individual luminaires under
Street Arrangement.
17
Figure 21 Light Distribution Icon
Under 3D Standard View of the scene (see Figure 22) notice that the luminaires
are not properly aligned with the border of the street. As a result, we will need to
modify the luminaires’ orientation to focus the light onto the road. Remember that
you can switch back and forth between 2D and 3D views of your scene using the
View menu from the main toolbar.
18
Figure 23 Modifying the Luminaires Rotation - 1
If properly done, the luminaires on the top side of the street must be facing down
towards the roadway.
19
Figure 25 Modifying the Luminares Rotation - 2
Upon completion, the luminaires on the bottom side of the street must be facing
up towards the roadway. The following figure displays the 3D Standard View of
the scene with the orientation of luminaires adjusted.
20
Optional – adding objects to the scene
Unlike the indoor and outdoor scenes you cannot add objects/furniture directly to
the street scene. If you intend to insert objects (e.g. cars, buildings, etc…) you
have to insert the street scene into an exterior scene. In order to do so, under the
tree structure, right-click on Street 1 and select Insert Street into Exterior Scene.
This will superimpose the street scene onto a “ground element”.
For instructions on how to build and insert objects into an exterior scene refer to
Tutorial 3.
21
Lighting Calculations:
In this step we will use the DIALux calculation tool to perform basic lighting
analysis.
To perform basic light scene calculations, select the Start Calculation icon from
the main toolbar menu. The Start Calculation icon can also be accessed from the
The Guide under the Street Lighting task area.
Clicking on the Start Calculation icon will open the Start Calculation dialogue box.
The dialogue box enables you to select the scenes to be included in the
calculation; click OK to continue.
22
Figure 29 Start Calculation Dialogue Box
Once you click OK, you will be prompted with the Calculating window, where you
can view the calculation progress. Calculation time varies based on different
parameters, such as the number of the luminaires used, the lighting scenes
created, etc...
23
Upon completion, DIALux shows a 3D display of the illuminated street in the CAD
Window.
To obtain a visual assessment of our design we will make use of the False Color
Display function of DIALux. The False Color Display can be accessed from the
main toolbar menu.
24
Once applied, the False Colors menu will open under Project manager, where
you can modify the foot candle (fc) values assigned to the display colors.
In this exercise we have built a street scene with an R2 pavement class, which
requires an illuminance value of 12 lm/m2 or 1.2 foot candles. Therefore, we will
assign a foot candle value of 1.2 fc to color White, Interpolate the values for the
other colors, and will Apply the modifications to verify our design. The following
figure shows the modified False Color Display of our lighting planning.
25
Figure 34 False Color Display
26
Calculation Results
In this step we will use the Output menu to display the calculation results. Even
though there are many output types available, we will only display/export those of
more importance to us. Remember that you have the option to display the
calculation results on the screen or to print/export them as a .pdf file. For the
purpose of this example we will export the results as a .pdf file. Once exported,
compare your results to those in Tutorial_4.pdf included with the tutorials.
Note: Based on the selected “Location”, “Time Specifications”, and the version of
DIALux you use your results may vary from those in Tutorial_4.pdf.
Once under the Output menu (see figure 32), deselect all preselected output
types and select the following:
Project 1
→add luminaire description if desired
→ add luminaire description if desired: LDC Data Sheet
→Street 1: Planning data
Photometric Results
3D Rendering
False Color Rendering
→Valuation Fields:
→Valuation Field Roadway 1: Results overview
Grey Scale (E)
Table (E)
→Valuation Field Sidewalk 1: Results overview
Grey Scale (E)
Table (E)
27
Figure 35 Output Menu
To export the calculation results click on the PDF icon in the main toolbar menu.
Once you click on the PDF icon you will be prompted with the Save Output as
PDF window inquiring you to confirm your selection. Click OK to continue.
28
Figure 37 Save Output as PDF Box
From the Photometric Results chart note that based on the calculated results the
uniformity (Emin/ Eav) for the roadway and sidewalks 1 and 2 was calculated to be
0.39 (0.37/0.95) and 0.51 (0.33/0.64), respectively. Consequently, we can
confirm that uniformity requirements (uo=0.25) for both illumination classes are
“Fulfilled”. However, in addition to the uniformity value itself, DIALux requires the
average illuminance value of S6 illumination class (in our case, sidewalks 1 and
2) not to exceed the minimum illuminance value by more than 1.5 times. This is
simply the reason why you notice an “ ” mark (i.e. not fulfilled) for the uniformity
calculation results of sidewalks 1 and 2.
29
The following figures illustrate different views of a completed version of the same
street scene we built in this tutorial. The purpose here is to demonstrate the
sophisticated yet simple functions of DIALux to create a street scene with the
greatest details.
30