Test Tools Catalog

Digital Multimeters

Portable Appliance Testers

Power Quality Tools

Clamp Meters

Digital Thermometers

Field Calibrators

Electrical Testers

Thermal Imagers

Vibration Tester

Insulation Testers

Distance Meters

Radiation Tester

Earth Ground Testers

Indoor Air Quality Tools

EX Test Tools

Installation Testers

ScopeMeter Test Tools

www.chorus.ro

Accessories

Contents
Fluke web and electronic newsletter .................................................... 1
New from Fluke........................................................................................ 2-3
Fluke Combo Kits..................................................................................... 4-5

Application/background articles ...................................................... 6


Fluke After Sales Service .................................................................. 7
Fluke where safety is built in .......................................................... 8-9
Fluke web/campaign......................................................................... 10

Digital Multimeters ............................................................................ 11


DMM Selection Guide ....................................................................... 12
280 Series Digital Multimeters ....................................................... 13
233 Remote Display Multimeter ...................................................... 14
80 Series V Digital Multimeters ....................................................... 15
170 Series Digital Multimeters ........................................................ 16
110 Series II Digital Multimeters ..................................................... 17
27 II / 28 II Rugged Industrial Multimeters .................................... 18
77 IV Digital Multimeter ................................................................... 19
88V Automotive Meter...................................................................... 20
8845A/8846A 6.5 Digit Precision Multimeters ............................... 21
8808A 5.5 Digit Multimeter .............................................................. 22

Clamp Meters and Electrical Testers ................................................ 23


Clamp Meter selection guide ........................................................... 24
381/365 Clamp Meters ...................................................................... 25
370 Series Clamp Meters .................................................................. 26
320 Series / 902 Clamp Meters......................................................... 27
353/355 AC/DC Clamp Meters .......................................................... 28
360 Current Leakage Clamp Meter ................................................. 29
T100 Series Voltage/Continuity Testers .......................................... 30
T5/T5-H5-1AC Kit Electrical Testers................................................ 31
2AC/1AC-II/LVD1/LVD2 Voltage Detectors...................................... 32
9040/9062 Phase Rotation Indicators.............................................. 33
2042 Cable Locator ............................................................................ 34

Insulation Testers/Earth Ground Testers ......................................... 35


Insulation Tester Selection Guide ................................................... 36
1577/1587 Insulation Multimeters .................................................. 37
1503/1507 Insulation Testers ........................................................... 38
1555/1550C Insulation Resistance Testers .................................... 39
1620 Series Earth Ground Testers ................................................... 40
1621 Earth Ground Tester ................................................................. 41
1630 Ground Loop Tester .................................................................. 42

Laser Distance Meters ....................................................................... 73


421D/416D/411D Laser Distance Meters ........................................ 74

Indoor Air Quality Tools .................................................................... 75


975 Air Meter...................................................................................... 76
922 Airflow Meter .............................................................................. 77
971 Temperature Humidity Meter................................................... 78
983 Particle Counter .......................................................................... 79

ScopeMeter Test Tools...................................................................... 80


ScopeMeter 190 Series II .................................................................. 81-83
ScopeMeter 120 Series ..................................................................... 84
ScopeMeter 225C/S and general specifications ............................ 85
ScopeMeter Accessories ................................................................... 86

Power Quality Tools ........................................................................... 87


Power Quality Selection Guide ........................................................ 88
345 Power Quality Clamp Meter ...................................................... 89
43B Single-phase Power Quality Analyzer ..................................... 90
1710 Single-Phase Voltage Quality Recorder ................................. 91
430 II Series Three-phase Power Quality Analyzers ..................... 92-93
1735 Power Logger ............................................................................. 94
1740 Series Power Quality Loggers.................................................. 95
1750 Power Recorder ......................................................................... 96
1760 Power Quality Recorder ........................................................... 97
Power Quality Current Clamp Accessories .................................... 98
Norma 4000/5000 Series ................................................................... 99-100

Field Calibrators ................................................................................. 101


Field Calibrator Selection Guide...................................................... 102
750 Series Documenting Process Calibrators ................................ 103
726/725/725Ex Multifunction Process Calibrators ........................ 104
724 Temperature Calibrator ............................................................. 105
712/714 Temperature Calibrators .................................................... 106
914X/418X Drywells/IR Calibrators ................................................. 107
717/718/718Ex/719 Pressure Calibrators......................................... 108
705/707/707Ex/715 Loop Calibrators ............................................... 109
771/772/773 mA Clamp Meters........................................................ 110
787/789 ProcessMeters...................................................................... 111
Field Calibrator Accessories............................................................. 112

Vibration Tester.................................................................................. 113


810 Vibration Tester .......................................................................... 114
Installation Testers/Portable Appliance Testers .............................. 43
1650 Series Multifunction Installation Testers.............................. 44-45
6000 Series Portable Appliance Testers .......................................... 46-47
1650/6000 Series Accessories ........................................................... 48

Digital Thermometers ....................................................................... 49


Infrared Thermometer Selection Guide ......................................... 50
570 Series Precision Infrared Thermometers ................................ 51
60 Series Infrared Thermometers ................................................... 52
566/568 Multipurpose Thermometers ............................................ 53
561 Multipurpose Thermometer ..................................................... 54
50 Series II Thermometers ............................................................... 55
1523/1524 Reference Thermometers .............................................. 56
1551A/1552A Ex Stik Thermometers ........................................... 57

Thermal Imagers ............................................................................... 58


Ti Series Thermal Imagers ............................................................... 59
Ti32/Ti29/Ti27 Industrial Thermal Imagers ................................... 60-61
TiR32/TiR29/TiR27 Industrial Thermal Imagers
for Building Diagnostics ................................................................... 62-63
Ti125/Ti110/Ti100 Industrial / Commercial Thermal Imagers .... 64-65
TiR125/TiR110/Ti100 Building Diagnostic Thermal Imagers ....... 66-67
Ti9/Ti10/Ti25 Thermal Imagers ....................................................... 68-69
TiS/TiR/TiRx/TiR1 Thermal for Building Inspection ..................... 70-71
Hawk IR CRange IRWindows ........................................................... 72

Radation Meter................................................................................... 115


481 Radation Meter ........................................................................... 116

ATEX Certified Test Tools .................................................................. 117


A brief look at ATEX .......................................................................... 118
Fluke intrinsically safe tools............................................................ 119

General Accessories........................................................................... 120


Electronic Test Leads, Probes & Clips ............................................. 121
Industrial Test Leads, Probes & Clips.............................................. 122-123-124
Automotive Accessories ................................................................... 125
Current Clamps ................................................................................. 126-127
Temperature Accessories ................................................................. 128-129
Cases and Holsters............................................................................ 130-131
Software and Other Accessories ..................................................... 132
Other Accessories.............................................................................. 133
Fuse and Warranty Information...................................................... 134

www.chorus.ro

Fluke. Keeping your world up and running

Fluke Web and


Electronic Newsletter

Fluke web
Complete information
The most complete and in-depth resource for
information on Flukes products and services
including:
Product information
Solution Centers
Interactive selection guides
Virtual product demonstrations
Extended specifications
Application notes
Product manuals
Service information
Promotions
Prices
Where to buy
Distributor and sales office locations

Find information fast


To quickly find more information on Fluke
products, use the Search by model box in the
top left corner of our web pages. All you have to
do is type in the model number.

UK: www.fluke.co.uk
IE: www.fluke.ie
Worldwide: www.fluke.com

Fluke web sites are available in all countries around the world and in 18 different languages.

Electronic Newsletter
E-Test-it! is Flukes regular news
publication for professional test tool
users. It is electronically available 6
times per year. You will be the first to
hear about:
New Fluke products
The latest actions and promotions from Fluke
How to get more out of Fluke tools
How to use Fluke tools better in your
application
Exclusive offers, promotions and discounts on
Fluke Merchandizing
Exclusive offers on Fluke ex-demo equipment
E-Test-it! is free of charge. If at any point in time
you do not want to receive E-Test-it! anymore,
you can unsubscribe with a simple mouse click.
E-Test-it! is small in size (on average about 12
KB) and does not fill up your mailbox or take
long to download.

www.chorus.ro

Try it now and sign-up for your FREE


e-Test-it! subscription.
Go to the Fluke web site and fill in the
on-line subscription form.

New from Fluke

Fluke 190 Series II Scopemeter


For the first time, plant maintenance engineers and technicians can
take a high-performance four-channel scope into the harsh world of
industrial electronics.
See page 81-83.

Fluke TiS Thermal Imaging Scanner


Fluke proudly introduces an entry level thermal imager for quick, easy, and
accurate problem identification and troubleshooting designed specifically for
the building inspection professional.
See page 70 and 71.

Fluke 1654B Multifunction Installation Tester


The new 1654B Installation Tester builds upon the rugged reputation of the earlier
1650 Series, only its re-designed to meet your need for more
productive test tools.
See page 44 and 45.

Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter


The Fluke 365 is a new, innovative Fluke clamp meter, offering a thin,
small jaw design that makes it easy to get around tightly packed wires.
See page 25.

Fluke 750 series Documenting Process Calibrators


Fluke 750 series process calibrators can help you get the job done faster. It does so
many different tasks, so quickly and so well, its the only process calibrator you need
to carry.
See page 103.

Fluke 370 series Clamp Meters


With this new family of clamp meters, Fluke provides a range of state of-the-art
capabilities to meet users most demanding requirements for flexibility, safety and
performance.
See page 26.

Fluke 381 Remote Display True-rms AC/DC ClampMeter with iFlex


The new Fluke 381 does everything you would expect from a clamp meter, and then
lets you remove the display for even more flexibility.
See page 25.

www.chorus.ro

New from Fluke

Fluke Ti27/Ti29 Thermal Imagers


Designed for industrial and commercial environments, the Fluke P3 series of thermal
imagers deliver superior image quality, versatility, and affordability without compromise.
See page 60-63.

Ti125/Ti110/Ti100/TiR125/TiR110 Thermal Imagers


Fluke proudly introduces five new thermal imagers specifically designed to help you do
more in less time, while being at home in the harshest of environments. A project that
might normally take an hour can now be done in minutes. Our newest imagers are the
lightest, most rugged, easiest-to-use professional imagers you can buy.
See page 64-67.

Fluke 430 Series II


Three-Phase Power Quality and Energy Analyzers
The new Fluke 434, 435 and 437 Series II models help locate, predict,
prevent, and troubleshoot power quality problems in three-phase
and single-phase power distribution systems.
See page 92-93.

1551A Ex and 1552A Ex Stik Thermometer


Accurate and repeatable to 0.05 C over its full range, the 1551A/1552A Stik
Thermometer is the new gold standard of industrial temperature calibration.
See page 57.

Fluke 1555/1550C Insulation Resistance Testers


The new 1555 and redesigned Fluke 1550C insulation resistance testers offer digital
insulation testing up to 10kV, making them ideal for testing a wide range of high
voltage equipment including switchgear, motors, generators and cables.
See page 39.

TL175 Twistguard Test Leads


The new Fluke TL175 TwistGuard Test Leads are the innovative test leads with adjustable
length test tips for use in different measurement environments.
See page 124.

www.chorus.ro

Fluke Combo Kits

Buy a Combo Kit and save


Fluke 117/322 Kit
Electricians Combo Kit
Fluke 117 True RMS
Multimeter
Fluke 322 Clamp Meter
Silicon test lead set
TPAK Magnetic Hanger
C115 Deluxe carrying case
with shoulder strap

Fluke 179/TPAK
179/ToolPak Combo Kit

Fluke 179/EDA2 Kit


Electronics Combo Kit
Fluke 179 True RMS
Multimeter
TL224 SureGrip Silicone Test
Lead Set
TL910 Electronic Test Probe
Set
AC280 SureGrip Hook Clip
Set
TPAK Magnetic Hanger
80BK-A Integrated DMM
Temperature Probe
C35 Soft Meter Case

Fluke 179/61 Kit


Multimeter and Infrared
Thermometer Combo Kit

Fluke 87V/E2
Industrial Electrician
Combo Kit

Ordering Information

Fluke 179 True RMS


Multimeter
TL224 SureGrip Silicone Test
Lead Set
AC220 SureGrip Alligator
Clip Set
TP74 lantern tip test probe set
TPAK Magnetic Hanger
80BK-A Integrated DMM
Temperature Probe
C35 Soft Meter Case
+ Maglite flashlight

Fluke 179 True RMS


Multimeter
TPAK ToolPak Meter Hanging
Kit

Fluke 179 True RMS


Multimeter
Fluke 61 Infrared
Thermometer
C550 Hard Meter and
Accessory Case

Fluke 117/322 Kit


Fluke 179/TPAK
Fluke 179/61 Kit
Fluke 179/MAG2 Kit
Fluke 179/EDA2 Kit
Fluke 87V/E2
Fluke 87V/i410

Fluke 179/MAG2 Kit


Industrial Combo Kit

www.chorus.ro

Fluke 87V True RMS


Multimeter
TL224 SureGrip Silicone Test
Lead Set
TP38 Slim Reach Test Probe
Set (insulated)
AC220 SureGrip Alligator
Clip Set
TPAK Magnetic Hanger
80BK-A Integrated DMM
Temperature Probe
C35 Soft Meter Case

Fluke 87V/i410
Combo Kit for Industrial
Applications
87V Industrial Multimeter
TL75 Test Leads
AC172 Alligator Clips
i410 400A AC/DC Current
Clamp
80BK-A Temperature Probe
C115 Soft Carrying Case
(Not available in all countries)

Fluke Combo Kits

Buy a Combo Kit and save


Fluke 287/FVF FlukeView
Forms Combo Kit
Fluke 287 True RMS Electronic
Logging Multimeter with
TrendCapture
FVF-SC2 FlukeView Forms
Software and cable
80BK-A Thermocouple Probe
CAT III 1000 V 10 A Modular
Test Leads (red, black)
CAT II 300 V 5 A Alligator Clips
(red, black)
C280 Soft Case for meter
protection and accessory
storage

Fluke 1587/MDT
Advanced Motor & Drive
Troubleshooting Kit
Fluke 1587 Insulation
Multimeter
Fluke 9040 Phase Rotation
Indicator
I400 Current Clamp
Fluke 1587/MDT

Fluke T5-H5-1AC Kit


Fluke 289/FVF Industrial
Logging Multimeter and
Software Combo Kit
Fluke 289 True-RMS
Multimeter
FVF-SC2 FlukeView Forms
Software and cable
Silicon Test Lead Set
AC172 Alligator Clips
80BK-A Integrated DMM
Temperature Probe
TPAK Magnetic Meter Hanger
for hands-free operation
C280 Soft Case for meter
protection and accessory
storage

Fluke T5-1000 Electrical Tester


H5 Holster
1AC-II Volt Alert

Fluke T5-600/62/IAC-E Kit


Fluke T5-600 Electrical Tester
Fluke 62 Mini IR Thermometer
Fluke 1AC-II Volt Alert
C115 Soft Meter Case

Fluke 1587/ET Advanced


Electrical Troubleshooting Kit
Fluke 1587 Insulation Multimeter
Fluke 62 Mini Infrared
Thermometer
I400 Current Clamp

Fluke 62/322/1AC Kit


Fluke 62 Mini IR Thermometer
Fluke 322 Clamp Meter
Fluke 1AC-II Volt Alert

Ordering Information
Fluke 287/FVF
Fluke 289/FVF
Fluke 1587/ET
Fluke 1587/MDT
Fluke T5-H5-1AC Kit
Fluke T5-600/62/IAC-E Kit
Fluke 62/322/1AC Kit
Fluke 411D/62 Kit

www.chorus.ro

Fluke 411D/62 Kit


Fluke 411D Laser Distance
Meter
Fluke 62 Mini IR Thermometer
Soft case for each model

Application/
background articles
As part of our commitment to supporting you in your work we do
more than just design and manufacture rugged and versatile test tools:
we also provide application notes which all can be downloaded from
our web site. Furthermore check out our total solutions campaigns
on the website. In addition to inspection tips and helpful application
information, these campaigns also offer advice on picking the right tool
for the job.

www.chorus.ro

Let Fluke After Sales Service


help you further

Did you know that the Fluke after sales


service team can offer you much more
than just repairing and calibrating your
instrument when it is needed? Across
our whole Fluke European service
organization we have a vast range of
capabilities, which can be utilized via
your local service centre. Behind the
scenes Fluke draws on the expertise of
over 150 service staff that are focused
on offering only the best and most
comprehensive after sales service.

What other value added services do


we offer?

So why should you use Fluke service?


Original manufacturers parts used
All instruments reviewed for latest updates
Repair warranty that covers whole unit
In depth product knowledge
Accredited calibrations available
Traceable calibrations available on all
products
Full check of unit during verification cycle
Full safety test on mains powered units

What other instruments can we help


you with?

Gold Support for Fluke Networks


Gold CarePlans for calibration products
A full range of maintenance contracts
Extended warranty programs
Instrument upgrades
Option retrofits
Asset management
Calibration reminders

What services do we offer you?


5 day repairs on all current products
5 days or less on all calibrations (excl.
repairs)
3 days for all Gold CarePlan calibrations
1-2 days on all Networks Gold calibration
Pick up services where available

We also offer a range of calibrations and


repairs on other manufacturers equipment
upon request. Manufacturers such as:
Tektronix
Agilent
Bruel & Kjaer
Philips
Megger
Seaward
Kewtech
Lecroy
Hioki
Yokogawa
Druck
Iwatzu
plus many more ...

Fluke service centres handle a wide range


of equipment.
As part of Flukes continuing focus on improving
our service to our customer we now offer a
comprehensive range of repairs and calibrations
on a vast range of equipment.
Fluke manufactures equipments such as:
Fluke Brands
Fluke
Hart Scientific
Fluke Networks
Fluke Biomedical
Raytek
Reliable Power Meters
Robin
LEM Instruments
BEHA
Norma
Wavetek/Datron
Metron
DHI
Comark

On-Line booking in system


Why not use our On-Line booking in system
where you can book your unit in, get pricing
and receive a RMA number for a smooth
return.
www.fluke.com/servicerma

Instrument Types
Digital Multimeters
Electrical Standards
Biomedical Equipment
Data Loggers
Thermal Imagers
Thermometers
Pressure
Function Generators
Oscilloscopes
Installation Testers
PAT Testers
Clamp Meters
Power Analyzers
EX meters
Plus many more

Contact Information
Telephone
Telefax
Email
Address

Eindhoven
+31 (0)40 267 5300
+31 (0)40 267 5321
servicedesk@fluke.nl
Science Park 5108
Eindhoven
5692 EC Son
Netherlands

www.chorus.ro

Norwich
+44 (0)1603 256620
+44 (0)1603 256688
ukservicedesk@fluke.com
52 Hurricane Way
Norwich
Norfolk
NR6 6JB
United Kingdom

Cologne
+49 (0)69 2222 20210
+49 (0)69 2222 20211
servicedeskgermany@fluke.com
Heinrich-Pesch-Str. 9-11
50739 Kln
Germany

Fluke: Where safety is built in

As distribution systems and loads


become more complex, the possibilities
of transient overvoltages increase.
Motors, capacitors and power conversion
equipment such as variable speed drives
can be prime generators of spikes.
Lightning strikes on outdoor transmission
lines also cause extremely hazardous
high-energy transients. If youre taking
measurements on electrical systems,
these transients are invisible and
largely unavoidable hazards. They occur
regularly on low-voltage power circuits,
and can reach peak values in the many
thousands of volts. To protect you against
transients, safety must be built into the
test equipment.

Who Develops Safety Standards?


The IEC (International Electrotechnical
Commission) develops international general
standards for safety of electrical equipment
for measurement, control and laboratory
use. IEC61010-1 is used as the basis for the
following national standards:
US ANSI/ISA-S82.01-94
Canada CAN C22.2 No.1010.1-92
Europe EN61010-1:2001

Overvoltage Installation Categories


IEC61010-1 specifies categories of
overvoltage based on the distance the piece
of equipment is from the power source
(see Fig. 1 and Table 1) and the natural
damping of transient energy that occurs
in an electrical distribution system. Higher
categories are closer to the power source and
require more protection.
Within each installation category there are
voltage classifications. It is the combination of
installation category and voltage classification
which determines the maximum transient
withstand capability of the instrument.
IEC 61010 test procedures take into account
three main criteria: steady-state voltage,
peak impulse transient voltage and source
impedance. These three criteria together will
tell you a multimeters true voltage withstand
value.

Figure 1. Understanding categories: location

of the 12 test source for CAT II. The CAT III


600 V meter clearly offers superior transient
protection compared to the CAT II 1000 V
meter, even though its so-called voltage
rating could be perceived as being lower. See
Table 2.

Independent testing is the key to safety


compliance
How can you tell if youre getting a genuine
CAT III or CAT II meter? Unfortunately its
not always that easy. It is possible for a
manufacturer to self-certify that its meter
is CAT II or CAT III without any independent
verification. The IEC (International
Electrotechnical Commission) develops and
proposes standards, but it is not responsible
for enforcing the standards. Look for the
symbol and listing number of an independent
testing lab such as UL, CSA, VDE, TV or other
recognized approval agency.
These symbols can only be used if the product
successfully completed testing to the agencys
standard, which is based on national and

international standards. UL 3111, for example,


is based on EN61010-1. In an imperfect world,
this is the closest you can come to ensuring
that the meter you choose was actually tested
for safety.

Within a category, a higher working voltage


(steadystate voltage) is associated with a
higher transient, as would be expected. For
example, a CAT III 600 V meter is tested
with 6000 V transients while a CAT III 1000 V
meter is tested with 8000 V transients.
So far, so good. What is not as obvious is the
difference between the 6000 V transient for
CAT III 600 V and the 6000 V transient for
CAT II 1000 V. They are not the same. This is
where the source impedance comes in. Ohms
Law (Amps = Volts/Ohms) tells us that the 2
test source for CAT III has six times the current

Table 1

Overvoltage category
CAT IV

In brief
Three-phase at utility connection,
any outdoor conductors

CAT III

Three-phase distribution, including


single-phase commercial lighting

CAT II

Single-phase receptable
connected loads

CAT I

Electronic

Examples
Refers to the origin of installation; i.e., where low-voltage connection is made to utility power.
Electricity meters, primary overcurrent protection equipment.
Outside and service entrance, service drop from pole to building, run between meter and panel.
Overhead line to d etached building, underground line to well pump.
Equipment in fixed installations, such as switchgear and polyphase motors.
Bus and feeder in industrial plants.
Feeders and short branch circuits, distribution panel devices.
Lighting systems in larger buildings.
Appliance outlets with short connections to service entrance.
Appliance, portable tools, and other household and similar loads.
Outlet and long branch circuits.
Outlets at more than 10 meters (30 feet) from CAT III source.
Outlets at more than 20 meters (60 feet) from CAT IV source.
Protected electronic equipment.
Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages
to an appropriately low level.
Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the
high-voltage section of a copier.

www.chorus.ro

Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment

Fluke: Where safety is built in

Safety is everyones responsibility but


ultimately it is in your hands.
No tool by itself can guarantee your safety
when working with electricity. Its the
combination of the right tools and safe
work practices that gives you maximum
protection. Here are a few tips to help you
in your work:
Make sure you always comply with (local)
regulations.
Work on de-energized circuits whenever
possible.
Use proper lock-out/tag-out procedures. If these
procedures are not in place or enforced, assume
that the circuit is live.

Use protective gear when working on live


circuits:
Use insulated tools
Wear safety glasses or a face shield
Wear insulated gloves, remove watches or
jewelry
Stand on an insulated mat
Wear flame resistant clothing, not ordinary
work clothes

Select the right test tool:

Inspect and test your test tool:

Choose a test tool rated to the highest


category and voltage for which it could
possibly be used (most often 600 or 1000
volt CAT III and/or 600 volt CAT IV).
Look for the category and voltage marking
near the recessed input connectors of your
test tool and a double insulated symbol
on the back.
Verify your test tool has been tested and
certified by two or more independent
testing laboratories, such as UL in the
United States and VDE or TV in Europe by
looking for the symbols of these agencies
on (the back of) your test tool.
Make sure that the test tool is made of
a high-quality, durable non-conductive
material.
Check the manual to verify that the
ohms, continuity and capacitance circuits
are protected to the same level as the
voltage test circuit, to reduce hazards
when the test tool is used incorrectly in
ohms, continuity or capacitance mode (if
applicable).
Verify that the test tool has internal
protection to prevent instrument damage
when voltage is incorrectly applied to
an amperage measurement function (if
applicable).
Make sure that the amperage and
voltage of your test tools fuses meets
specifications. Fuse voltage must be as high
or higher than the test tools voltage rating.
Be sure to use test leads that have:
- Shrouded connectors
- Finger guards and a non-slip surface
- Category ratings that equal or exceed
those of the test tool
- Double insulation (look for the symbol)
- A minimum of exposed metal on the
probe tips

Check for a broken case, worn test leads or


a faded display.
Make sure the batteries still deliver
sufficient power to get reliable readings.
Many test tools have a low battery indicator
on the display.
Check the test leads resistance for internal
breaks while moving the leads around
(good leads measure 0.1-0.3 Ohm).
Use the meters own test capability to
ensure that the fuses are in place and
working right (see manual for details).

Apply the appropriate working


practices when measuring on live
circuits:
Hook on the ground clip first, then make
contact with the hot lead. Remove the hot
lead first, the ground lead last.
Use the three-point test method, especially
when checking to see if a circuit is dead.
First test a known live circuit. Second,
test the target circuit. Third, test the live
circuit again. This verifies that your test
tool worked properly before and after the
measurement.
Hang or rest the test tool if possible.
Try to avoid holding it in your hands, to
minimize personal exposure to the effects
of transients.
Use the old electricians trick of keeping
one hand in your pocket. This lessens the
change of a closed circuit across your chest
and through your heart.

Use protective equipment such as safety glasses and


insulated gloves

Table 2
Overvoltage
Installation
Category
CAT I
CAT I
CAT II
CAT II
CAT III
CAT III
CAT IV

Working Voltage
(DC or AC RMS
to ground)
600 V
1000 V
600 V
1000 V
600 V
1000 V
600 V

www.chorus.ro
Use meters with these markings:
1000 V CAT III or 600 V CAT IV

Peak Impulse
Transient
(20 repetitions)
2500 V
4000 V
4000 V
6000 V
6000 V
8000 V
8000 V

Test Source
( = V/A)
30 Ohm source
30 Ohm source
12 Ohm source
12 Ohm source
2 Ohm source
2 Ohm source
2 Ohm source

Transient test values for overvoltage installation categories.


(50 V/150 V/300 V values not included)

Fluke Solution
Fluke total solutions campaigns

Fluke has launched a total solutions campaign focused on all our products and the benefits for you. Discover how Fluke tools can
help you make or save money. You can find a wide range of useful background information, www.flukesolution.co.uk

Plant Maintenance
Focus on motors and drives, energy saving and process trouble shooting, where Flukes Test & Measurement tools can help you
make the difference. Learn more about our latest developments in for example inspecting motors and drives.

Thermography
Focus on the user experience of our Thermal Imagers and experience the wide-ranging benefits of thermal imaging in everyday onthe-job situations. See what Fluke Thermography has to offer to make your work easier.

Energy
Focus on energy saving benefits in the industrial maintenance market. Fluke Test & Measurement tools help you to detect problems
and/or monitoring situations prevention- before they become critical. Learn how we can help you make or save money in your
plant or industry.

10

www.chorus.ro

www.flukesolution.co.uk
Visit the full portal to get all your troubleshooting solutions from one source. Every Fluke tool is built around one ideaYou!

Digital Multimeters
Safety, quality and performance: three words that sum up the benefits of
our extensive range of digital multimeters. Designed to help you do your
job faster, more efficiently and with greater accuracy, there is a model for
every budget and application. Choose from handheld troubleshooters to
ultra smart instruments packed with features, including the ability to log
and graph data, as well as high-precision bench units.

www.chorus.ro

11

12

www.chorus.ro

Basic features
Counts
True RMS readings
Basic DC accuracy
Wide bandwidth
Auto/manual ranging
Measurements
Voltage AC/DC
Current AC/DC
Resistance
Frequency
Capacitance
Temperature
dB
Conductance
Duty cycle/pulse width
Continuity with beeper/Diode test
4-20mA loop current as % readout
Motor drive measurement
RPM/Dwell
VoltAlertTM, Non-contact voltage detection
LoZ: low input impedance
VCHEKTM LoZ
Microamps
Insulation test
Number of insulation test ranges
Display
Dual display
Analog bargraph
Backlight
Remote display
Data storage and exchange
Min-Max recording/with time stamp
Fast Min-Max
Display Hold/Auto (Touch) Hold
Relative
Stand alone logging/TrendCapture
USB interface/RS232 interface
Readings memories
Other features
Source 4-20mA loop current/24V loop supply
Automatic selection, AC/DC volts
Real time clock
Smoothing
Integrated holster
Removable holster
Closed case calibration
Seperate battry/fuse access
Completely sealed/watertight
Automatic power off
Low battery indication
Warranty and safety
Lifetime warranty/warranty (years)
Input alert
Dangerous voltage indication
EN61010-1 CAT III
EN61010-1 CAT IV
See catalog page
287

O/O

6000
AC
0.25%

233

Remote
display

20000
AC
0.05%
20 kHz
O/O

87V

0.1%
5 kHz
O/O

6000

83V

High-end Industrial

O/O

6000
AC
0.09%

179

O/O

6000
AC
0.09%

177

O/O

6000
AC
0.15%

175

Industrial maintenance
and field service

O/O

6000
AC
0.5%

117

Electrical

O
O
O

O/O
250 s
O/O
O
O/O
O/O
10000

O
O
O
O/O
O
O
O
O
O
1000 V
600 V
13

O
O
O

O/O
250 s
O/O
O
O/O
O/O
10000

O
O/O

O
O

O
O
O
1000 V
600 V
13

O
1000 V
600 V
14

O
O/O

O
O

O
O
O
1000 V
600 V
15

O
O

O
O
O/-

O/250 s
O/O
O

O
O

O
O
O
1000 V
600 V
15

O
O

O
O
O/-

O/O
O

O/-

O
O

O
1000 V
600 V
16

O
O

O
O/O

O
O

O/O

O/-

O
O

O
1000 V
600 V
16

O
O

O
O/O

O
O

O/O

O/-

O
O

O
1000 V
600 V
16

O
O

O
O/O

O
O

O/O

O/-

O
600 V
17

17

O
O

O
600 V

O
O

O
O
O/-

O
O
O/-

O/-

O/-

O
O

17

O
600 V

O
O

O
O
O/-

O/-

O/-

O
O

O/O

O/O

600 V
10 A
40 M
50 kHz
10 mF

O/O

6000
AC
0.5%

115

Field
Service

600 V
200 A
40 M
50 kHz
10 mF
+400C

O/O

6000
AC
0.5%

116

HVAC/R

O/-

O/-

O
O

O
O

1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V


600 V
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
500 M 500 M 40 M 50 M 50 M 50 M 50 M 50 M 40 M
1 MHz 1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz
100 mF 100 mF 10 mF
10 mF
10 mF
10 mF
10 mF
10 mF
10 mF
+1350C +1350C +400C +1090C
+400C
60 dB
60 dB
50 nS
50 nS
60 nS
60 nS
O/O
O/O
O/O/O/O
O/O
O/O
O/O
O/O
O/O
O/O
O/O
O/O

50000
50000
AC+DC AC+DC
0.025% 0.025%
100 kHz 100 kHz
O/O
O/O

289

Highest accuracy

113

17

O
600 V

O
O

O
O
O/-

O/-

O/-

O
O

O/-

60 k

40 M

17

O
600 V

O
O

O
O
O/-

O/-

O/-

O
O

O/O

10 mF

600 V

O/O

6000
AC
2.0%

600 V

O/O

6000
AC
0.5%

114

Basic Electrical

28II

20000
AC
0.05%
50 kHz
O/O
O/O

0.3%

6000

77IV

General
Purpose

O/O

0.1%

20000

88V

Automotive

O/O

4000
AC
0.1%

789

O
O
O
1000 V
600 V
18

O
O
O/O
O
O
O

O/O
O

O/-

O
O

60 nS
O/O
O/O

O
O
O
1000 V
600 V
18

O
O
O/O
O
O
O

O/250 s
O/O
O

O
O

60 nS
O/O
O/O

O
1000 V
600 V
19

O
O

-/O

O/-

O
O

O/O

O
O
O
1000 V
600 V
20

O
O

O
O
O/-

O/250 s
O/O
O

O
O

O/-

60 nS
O/O
O/O

111

1000 V

O
O

O
O/O

O/O

O/O

-/O
O

O/-

O
O
O

O/O
O

O/O

6000
AC
0.09%

1587

O/O

6000
AC
0.2%

1577

Insulation test

111

1000 V

O
O

O/-

O/-

-/O
O

O/-

O/O
O

O
1000 V
600 V
37

O
O

O
O
O/O

O/O

O/-

O
5

O/O

O
1000 V
600 V
37

O
O

O
O
O/O

O
2

O/-

1000 V 1000 V 1000 V


1A
400 mA 400 mA
40 M 50 M 50 M
20 kHz 100 kHz
10 mF
+500C

O/O

4000
AC
0.1%

787

Loop calibration

1000 V 1000 V 1000 V 1000 V 1000 V


10 A
10 A
10 A
10 A
1A
50 M 50 M 50 M 50 M 40 M
200 kHz 200 kHz 100 kHz 200 kHz 20 kHz
10 mF
10 mF
10 mF
10 mF
+1090C
+1090C

0.1%
20 kHz
O/O

6000

27II

Heavy duty
(IP67)

DMM Selection guide

280 Series Digital Multimeters


Advanced diagnostic and logging
functionality for maximizing productivity
Replacing the popular 180 Series, the
Fluke 289 and Fluke 287 represent the
next generation of high-performance
industrial logging multimeters,
including higher accuracy and greater
troubleshooting convenience than ever
before. With the ability to log data and
review it graphically on the large display,
you can solve problems faster and help
minimize downtime, while working at
several locations.
Large 50,000 count 320 x 240 (1/4 VGA)
dot matrix display

Logging function with TrendCapture for


easy review of logged data
Multiple readings per display provide
more information at a glance
I-info button for convenient on-board
help
PC interface for easy data transfer
In addition, the Fluke 289 provides:
Lo Pass filter for motor drive
measurements
LoZ Low impedance function prevents
false ghost voltage readings
50 range for motor winding and low
ohm measurements

Features

Fluke 289
287

289

AC, AC+DC

AC, AC+DC

100 kHz / 100 kHz

100 kHz / 100 kHz

50.000 / 50.000

50.000 / 50.000

O
O

O
O

Up to 180 h

Up to 180 h

O
O

O
O
O

True-RMS measurements
Bandwidth (voltage/current)

Fluke 287

Digital display counts (default/selectable)


Logging function with TrendCapture
Records events and trends
Internal memory
Saves measurements
Optical USB PC communications interface
Low input impedance function (LoZ)
Motor winding and low ohm measurement range

50

Low pass filter


Field upgradeable/expandable meter
Navigation keys
F1-F4 soft keys/user function menus
I-info button/on board help screens

Precise performance

View logged data graphically


on screen

O
O
O
O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O
O
O

Multilingual interface
Saves preferred measurement setups
Current measurement: 20 A (30 seconds momentary; 10 A continuous)
Peak capture (records transients as fast as 250 s)
Continuity measurement
Min/Max/Average with Time Stamp (records signal fluctuations)
IP Rating 54

Specications
(Check the Fluke web for detailed specications)
True RMS

Included Accessories
TL175 test leads, AC172 alligator clips, probe
holder, 6 AA batteries (installed), user manual,
Calibration Certificate Sheet.

Ordering Information
Fluke 287

True-RMS Electronic logging


multimeter with TrendCapture
Fluke 289
True-RMS Industrial logging
multimeter with TrendCapture
Fluke 289/FVF Industrial logging multimeter
and Software Combo Kit
(see page 5)
Fluke 287/FVF FlukeView Forms Combo Kit
(see page 5)
FVF-SC2
FlukeView Forms software
including IR/USB cable

Functions

Maximum

Max. resolution

287 and 289**

Voltage DC

1000 V

1 V

(0.025% + 5)

Voltage AC

1000 V

1 V

(0.4% + 40)

Current DC

10 A

0.01 A

(0.15% +2)

Current AC

10 A

0.01 A

(0.7% + 5)

Temperature

-200 C to 1350 C

0.1 C

(1.0% + 1 C)

Resistance

500 M

0.01

(0.05% + 2)

Conductance

50 nS

0.01 nS

(1.0% + 10)

Capacitance

100 mF

0.001 nF

(1.0% + 5)

Frequency

1 MHz

0.01 Hz

(0.005% + 1)

Accuracies are best accuracies for each function.


** 287 and 289 accuracy and resolution are stated for 50.000 counts

Battery life: 50 hours minimum,


180 hours in logging mode
Size (HxWxD): 222 mm x 102 mm x 60 mm

Weight: 0,871 kg
Lifetime warranty

Recommended Accessories

www.chorus.ro
TLK289
See page 123

TL910
See page 121

TLK287
See page 121

TPAK
See page 132

C280
See page 130

13

233 Remote Display Multimeter


Ultimate flexibility with removable display
The Fluke 233 remote display digital
multimeter allows you to be in two
places at once. The removable display
solves the problems of holding both
the meter and the test leads to make a
measurement, making measurements
in hard-to-reach places, and making
measurements in machines or panels
that are physically separated from a limit

switch or an isolator switch. Wireless


technology allows the display to be
carried up to 10 meters away from the
point of measurement. The Fluke 233
is also designed to work in areas where
the operator cant be close to the active
measurement point, like clean rooms or
hazardous areas.

Features
233
Removable magnetic display

True-RMS measurement

Digital display counts

6000

Display backlight

Built in thermometer

Resistance, continuity and diode test

Min/Max and average recording

Auto power off maximizes battery life

Radio transmitter automatically turns off when


the display is connected to the meter

Use as conventional multimeter when the display is connected

Safety rating

CAT IV 600 V / CAT III 1000 V

Auto and manual ranging


Fluke 233

Display Hold and AutoHOLD

Unsafe voltage alert warns for voltages above 30V

2 Low batteries indication

Ergonomic case with integrated holster

Selectable sleep mode preserves battery life

Specications
On all inputs
Functions

True RMS

Included Accessories
Test leads with 4mm lantern tips, AC 172
alligator clips, 80BK-A temperature probe,
CD-ROM, AA batteries and user manual.

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature
Wireless frequency: 2.4 GHz ISM Band 10 meter range

Maximum
1000 V
1000 V
10 A
10 A
40 M
9999 F
50.00 kHz
-40 C to +400 C

Fluke 233
Max. Resolution
0.1 mV
0.1 mV
1 mA
1 mA
0.1
1 nF
0.01 Hz
0,1 C

Accuracy
(0.25% + 2)
(1.0% + 3)
(1.0% + 3)
(1.5% + 3)
(0,9% + 1)
(1,9% + 2)
(0,1% + 2)
(1% + 10)

Accuracies are best accuracies for each function

Ordering Information
Fluke 233

Remote Display Multimeter


Battery Life: AA alkaline (3 for main body,
2 for display), 400 hrs typical
Size (HxWxD): 193 x 93 x 53 mm

Weight: 0.6 kg
Three year warranty

Recommended Accessories

www.chorus.ro
80AK-A
See page 128

14

80PK-9
See page 128

i410
See page 127

Tpak
See page 132

C35
See page 130

80 Series V
Digital Multimeters
Performance and accuracy for
maximum industrial productivity
The Fluke 80 Series V have improved
measurement functions, troubleshooting
features, resolution and accuracy to solve
more problems on motor drives, in plant
automation, power distribution, and
electro-mechanical equipment.

The Fluke 87V has a unique function


for accurate voltage and frequency
measurements on adjustable speed
motor drives and other electrically noisy
equipment. A built-in thermometer
conveniently allows you to take
temperature readings without having to
carry a separate instrument. For 87V Ex
see also page 118 and 119.

Features
83V

Fluke 83V

5 kHz

20 kHz

Digital display counts (default/selectable)

6000

20000 / 6000

Selectable filter for accurate voltage and frequency


measurements on motor drives
Large display with analog bargraph and 2 level bright
white backlight
Auto and manual ranging for maximum flexibility

Fluke 87V

83V/87V

87V / 87V Ex
O

True-RMS voltage and current for accurate


measurements on non linear signals
Bandwidth (voltage/current)

O
O

Built-in thermometer lets you carry one less tool

Peak capture to record transients as fast as 250 s

Relative mode to remove test lead resistance from low


ohms measurements
Min-Max-Average recording with Min/Max Alert to
capture variations automatically
AutoHOLD to capture stable readings avoiding noisy
signals
Audible continuity, diode test and duty cycle

Input Alert

Classic design with new removable holster with built


in test lead and probe storage
Improved selectable sleep mode for long battery life

Easy battery exchange without opening the complete


case

ATEX safety rating

87V Ex

II 2 G Eex ia IIC T4

Specications
On all inputs

(Check the Fluke web for detailed specications)

Fluke 87V Ex
Functions

True RMS
not 87V Ex

Included Accessories
TL175 test leads, AC172 alligator clips, yellow
holster (H80M excl. TPAK), 80BK temperature
probe (87V only), 9 V battery (installed),
CD-ROM (users manual and technical notes)
and operators guide.

Ordering Information
Fluke 83V
Multimeter
Fluke 87V
True RMS Multimeter
Fluke 87V Ex Intrinsically safe
True RMS multimeter
Fluke 87V/E2 Industrial Electrician Combo
Kit
See page 4

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Conductance
Capacitance
Frequency
Temperature
80BK temperature probe

Maximum Range

83V

87V/87V Ex*

Max. resolution

Accuracy

Max.
resolution

Accuracy

0.1 mV
0.1 mV
0.1 A
0.1 A
0.1
0.01 nS
0.01 nF
0.01 Hz

(0.1%+1)
(0.5%+2)
(0.4%+2)
(1.2%+2)
(0.4%+1)
(1.0%+10)
(1.0%+2)
(0.005%+1)
-

10 V
10 V
0.01 A
0.01 A
0.01
0.001 nS
0.01 nF
0.01 Hz
0.1 C
-

(0.05%+1)
(0.7%+2)
(0.2%+2)
(1.0%+2)
(0.2%+1)
(1.0%+10)
(1.0%+2)
(0.005%+1)
1.0%
2.2 C or 2%

1000 V
1000 V
10 A **
10 A **
50 M
60 nS
9999 F
> 200 kHz
-200 to 1090 C
-40 to 260 C

Accuracies are best accuracies for each function.


* 87V accuracy is stated for 6000 counts and resolution for 20000 counts
** 20 A up to 30 seconds

Battery Life: Over 400 hours typical (alkaline).


Size (HxWxD):
200 mm x 95 mm x 48 mm

Weight: 0.6 kg
83V/87V: Lifetime Warranty
87V Ex: One Year Warranty

Recommended Accessories
(Not for hazardous zones)

www.chorus.ro
C25
See page 130

TL238
See page 122

i410/i1010
See page 127

TPAK
See page 132

L215
See page 123

15

170 Series Digital Multimeters


Versatile meters for field service or
bench repair
These meters have the features needed
to find most electrical, electromechanical and heating and ventilation
problems.
They are simple to use and have
significant improvements over Flukes
original 70 Series like True-RMS, more
measurement functions, conformance to
the latest safety standards, and a much
larger display thats easier to view.

Features
True-RMS measurements

175
AC

177
AC

179
AC

Digital display counts, updates 4 times per second

6000

6000

6000

Display backlight
Fluke 177

Fluke 179

Fluke 175

Analog bargraph / 33 segments, updates 40 times per


second
Auto and Manual ranging

Display Hold and AutoHOLD

Min-Max-Average recording mode with Min/Max Alert

Temperature readings (bead thermocouple probe


included)
Smoothing mode allows filtering of rapidly changing
inputs
Audible continuity and diode test

Test lead alert

Unsafe voltage alert warns for voltages above 30V

Low battery indication

Ergonomic case with integrated holster

Easy battery and fuse exchange without opening the


complete case
Selectable sleep mode preserves battery life

Specications

On all inputs

(Check the Fluke web for detailed specications)


True RMS

Included Accessories
Test leads with 4 mm lantern tips, installed
9V battery and users manual. The 179 also
includes the 80BK temperature probe.

Ordering Information
Fluke 175
Fluke 177
Fluke 179
Fluke 179/EDA2 Kit
Fluke 179/MAG2 Kit

True RMS Multimeter


True RMS Multimeter
True RMS Multimeter
Electronics Combo Kit
Industrial Combo Kit
See page 4

Functions
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Max. resolution
0.1 mV
0.1 mV
0.01 mA
0.01 mA
0.1
1 nF
0.01 Hz
0.1 C

175
(0.15%+2)
(1.0%+3)
(1.0%+3)
(1.5%+3)
(0.9%+1)
(1.2%+2)
(0.1%+1)

177
(0.09%+2)
(1.0%+3)
(1.0%+3)
(1.5%+3)
(0.9%+1)
(1.2%+2)
(0.1%+1)

179
(0.09%+2)
(1.0%+3)
(1.0%+3)
(1.5%+3)
(0.9%+1)
(1.2%+2)
(0.1%+1)
(1.0%+10)

Accuracies are best accuracies for each function

Battery Life: Alkaline, 200 hrs typical


Size (HxWxD): 190 mm x 85 mm x 45 mm

Weight: 0.42 kg
Lifetime Warranty

Recommended Accessories

www.chorus.ro
i400
See page 126

16

Maximum
1000 V
1000 V
10 A
10 A
50 M
10000 F
100 kHz
-40 C/+400 C

C90
See page 130

TLK-220
See page 122

SV225
See page 133

i410-i1010
See page 127

110 Series Digital Multimeters


Compact design for ergonomic
one-handed operation
Fluke 115 Field Service Testing
Multimeter

The Fluke 110 Series has five true-rms


DMMs, each for specific users. The compact
instruments offer convenient one-handed
operation and a backlit display with large, easyto-read digits.

An everyday multimeter for technicians, the


115 is for electrical and electronic testing in
field service, industrial, and applications where
more than the basic functions simplify work.

Fluke 117 Electricians Multimeter with


Non-Contact Voltage

Fluke 115

Fluke 114 Electrical Multimeter

The 117 is for electricians working in


commercial and non-commercial premises
(like hospitals and schools). It includes extras
like non-contact voltage detection for faster
and safer operation.

The 114 is for electrical troubleshooting and


straightforward go/no-go in residential/
commercial testing. It has all the basic
functions plus a special feature to prevent false
readings caused by ghost voltage.

Fluke 116 Multimeter with Temperature


and Microamps

Fluke 113 Multimeter


The 113 is for basic electrical tests and
repairing most electrical problems. Features
include Flukes VCHEK, added measurement
functions, backlight and conformance to the
latest safety standards.

The 116 is for heating, ventilation and air


conditioning (HVAC) engineers. It includes
temperature measurement and microamp
current ranges to quickly troubleshoot HVAC
problems.

Fluke 117

Features
113

114

115

116

AC

AC

AC

AC

AC

6000

6000

6000

6000

6000

Backlight

Analog bargraph

True RMS readings


Counts

Fluke 114

AutoVolt: Automatic AC/DC voltage selection

117

VoltAlert, Non-contact voltage detection

Built-in thermometer for HVAC applications

LoZ: low input impedance to prevent ghost voltage

VCHEK LoZ low impedance measurement function to


simultaneously test for voltage or continuity

Min/Max/Average to record signal fluctuations

Resistance, continuity

-/ O/O

Frequency, Capacitance, Diode test

Microamps to test flame sensors

Fluke 116

O

Display hold

Auto/manual ranging

Low battery indication

Compact case with removable holster

Specications
(Check the Fluke web for detailed specications)
Functions
Fluke 113
On all inputs

True RMS

Included Accessories
Test leads with 4 mm lantern tips, holster,
installed 9V battery and users manual

Voltage DC

Maximum

Max. resolution

113

114

115

116

117

(0.5%+2)

(0.5%+2)

(0.5%+2)

(0.5%+2)

(0.5%+2)

(1.0%+3)

(1.0%+3)

(1.0%+3)

(1.0%+3)

600V

1mV

Voltage AC

600V

1mV

Current DC

10.00A

1mA

(1.0%+3)

Current AC

10.00A

0.01A

(1.5%+3)

Resistance

40M (113: 60K) 0.1

(0.9%+2)

Capacitance

10000F

1nF

(1.9%+2)

Frequency

50kHz

0.01Hz

Temperature

-40C/+400C

0.1C

VCHEK

600.0V AC/DC

0.1V

(0.9%+1)

(1.0%+3)
(1.5%+3)

(0.9%+1)

(0.9%+1)

(0.9%+1)

(1.9%+2)

(1.9%+2)

(1.9%+2)

(0.1%+2)

(0.1%+2)

(0.1%+2)

(1.0%+10)
(2.0%+3)

Accuracies are best accuracies for each function

Ordering Information
Fluke 113
Fluke 114
Fluke 115
Fluke 116
Fluke 117
Fluke 117/322 Kit

True RMS Multimeter


True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
True RMS Multimeter
Electricians Combo Kit
(see page 4)

Battery type: 9 volt Alkaline, 400 hours typical Weight: 0.55 kg (including batteries)
Size (HxWxD): 167 mm x 84mm x 46 mm
Three Year Warranty

www.chorus.ro

Recommended Accessories

C50
See page 130

TL223-1
See page 122

MC6
See page 133

TPAK
See page 132

17

27II / 28II Rugged IP67 Industrial


Multimeters
Designed to survive water, dust and rough
handling and yet troubleshoot most electrical
problems
The Fluke 27 II and 28 II digital
multimeters define a new standard for
operating in harsh conditions with the
features and accuracy to troubleshoot
most electrical problems. Both meters
have IP 67 (waterproof and dustproof)
rating, MSHA approvals, extended
operating temperature range of -15 C to
+ 55C and 95% humidity, and a 3-meter
drop. They withstand hazardous 8.000
volt spikes caused by load switching and

faults on industrial circuits and complies


with second edition IEC and ANSI
electrical safety standards.
Furthermore, the 28 II has a unique
function for accurate voltage and
frequency measurements on adjustable
speed motor drives and other electrically
noisy equipment.
The new Fluke 20 series multimeters
are built to work in the toughest
environments.

Features
27 II

28 II

IP 67 waterproof & dustproof protection

Withstands 3 meter drop (with holster)

True-RMS measurements
Fluke 27 II

6000

20000/6000

Bright, two-level backlight

Digital display counts

Backlit keypad buttons

Reversible, rubber holster

Resistance, continuity and diode test

Min/Max and average recording

Improved sleep mode for long battery life

Relative mode to remove test lead resistance


from low ohms measurements

Auto and manual ranging

CAT III 1000 V


CAT IV 600 V

CAT III 1000 V


CAT IV 600 V

Built-in thermometer

Safety rating

Specications

True RMS
Fluke 28 II

Functions

Maximum

Voltage DC
Voltage AC
Current DC
Current AC
Temperature

On all inputs

Resistance
Low pass filter (Measurement on VSDs)
Capacitance
Frequency
Peak transient capture

1000 V
1000 V
10 A
10A
-200C to
+1090C
50M
9999F
200 kHz

Max.
Resolution
0.1 mV
0.1 mV
0.1 A
0.1 A
0.1C

27 II

28 II

(0.1% + 1)
(0.5% + 3)
(0.2% + 4)
(1.5% + 2)

(0.05% + 1)
(0.7% + 4)
(0.2% + 4)
(1.0% + 2)
(1% + 10)

0.1
0.01nF
0.01 Hz

(0.2% + 1)
yes
(1% + 2)
0.005% + 1
250 S

Accuracies are best accuracies for each function

Included Accessories

Battery Life: 3x AA alkaline, 800 hrs typical


Size (HxWxD): 198 x 100 x 63.5 mm

TL175 Test leads, AC172 alligator clips,


80BK-A temperature probe (28 II), holster,
manual, CD-ROM, three AA batteries
(installed)

www.chorus.ro

Weight: 0.75 kg
Lifetime Warranty

Recommended Accessories

Ordering Information

18

Fluke 27 II IP 67 Industrial Multimeter


Fluke 28 II IP 67 True-RMS Industrial Multimeter

PV 350
See page 125

i200
See page 126

i410
See page 127

80K-6
See page 133

77IV Digital Multimeter


Versatile multimeter for field service
or bench repair
The 77-IV digital multimeter has the
features needed to repair most electrical
and electronic problems. This meter
is simple to use and has significant
improvements over Flukes original
70 Series with more measurement
functions, conformance to the latest
safety standards, and a much larger
display thats easier to view.

Features
77 IV
6000
O
O
O
31
O
O
O
O
O
CAT IV 600 V / CAT III 1000 V

Digital display counts


Large display with backlight
Min-Max-Average recording mode with Min/Max Alert
High contrast digital display with large digits
Analog bargraph/segments
Auto and Manual ranging
Automatic Touch Hold
Audible continuity / diode test
Ergonomic case with integrated holster
Sleep Mode preserves battery life
EN 61010-1 safety rating

Fluke 77 IV

Specications
Function
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency

Maximum
1000 V
1000 V
10 A
10 A
50 M
9999 F
99.99 kHz

Max. resolution
1 mV
1 mV
0.01 mA
0.01 mA
0.1
1 nF
0.01 Hz

Accurancy
(0.3%+1)
(2.0%+2)
(1.5%+2)
(2.5%+2)
(0.5%+1)
(1.2%+2)
(0.1%+1)

Accuracies are best accuracies for each function.

Battery Life: 400 hours typical


Weight: 0.42 kg
Size (HxWxD): 185 mm x 90 mm x 43 mm Lifetime Warranty
On all inputs

Recommended Accessories

Included Accessories
Test leads with 4mm lantern tips, operators
manual, 9V battery (installed)

www.chorus.ro
Ordering Information
Fluke 77IV

Multimeter

i400
See page 126

C35
See page 130

Tpak
See page 132

TL225
See page 133

TLK-225
See page 123

19

88V Automotive Meter

The right meter for auto-electric diagnosis


Perhaps the most important tool youll
use in troubleshooting auto electrical
systems is the multimeter. Basic
multimeters measure voltage, current
and resistance, while automotive
multimeters like the Fluke 88V have
features that can check frequency, duty
cycle, make diode tests, and measure
temperature, pressure and vacuum.

Features
Continuity for detecting open and shorts

88V/A
O

Frequency for pulsed-DC and AC tests

Duty cycle to verify operation of feedback carburetors

Diode test for alternator testing

Built-in thermometer; thermocouple probe included

Min/Max/Average recording with Min/Max Alert

Peak capture to record transients as fast as 250 s

Relative mode to remove test lead resistance from low ohms measurements

Millisecond pulse width measurements for fuel injectors

AutoHOLD to capture stable readings

Large display with bright, two-level backlight

Magnet hanger to attach meter to the vehicle

RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions

Fluke 88V/A

Hard Meter Case

Safety rating

CAT III 1000 V,


CAT IV 600 V

Specications
On al inputs

Included Accessories
H80M Holster with TPAK Meter Hanging
Solution, TL224 SureGrip Silicone Test Lead
Set, TP74 Test Probe Set, AC285 SureGrip
Large Jaw Alligator Clip Set, 80BK Integrated
Temperature Probe, RPM80 Inductive Pick-up
Probe, C800 Hard Case, Users Manual + Quick
Reference Guide

Range
1000V
1000V (5 kHz)
10A
10A
50M
10mF
200kHz
1090C

Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Fluke 88V
Resolution
0.1mV
0.1mV
0.1A
0.1A
0.1
0.01nF
0.01Hz
0.1C

Accuracy
0.1%
0.5%
0.4%
1.2%
0.4%
1%
0.01%
1%

Battery Life: 88V Over 400 hours typical


Weight: 88V 0.36 kg
(alkaline)
Lifetime Warranty
Size (HxWxD): 88V 186 mm x 86 mm x 32 mm

Ordering Information
Fluke 88V/A Automotive Meter Combo Kit

Recommended Accessories

www.chorus.ro
TL82
See page 125

20

TLK-282-1
See page 125

90i-610s
See page 125

80PK-27 (requires 80AK)


See page 128

PV350
See page 125

8845A/8846A
6.5 Digit Precision Multimeters
Precision and versatility for bench or
systems applications
The Fluke 8845A and 8846A, 6.5 digit
precision multimeters have the precision
and versatility to handle your most
demanding measurements on the bench
or in a system.

Fluke 8845A

Perform 4-wire measurements easily


with two leads: Patented split terminal
jacks for 2x4 Ohms function allows you
to perform precise 4-wire measurements
with only two leads instead of four.
Optional Kelvin leads accessories are
available to enable you to establish a 4wire connection even in tight spaces.
Systems Capabilities: Both instruments
include an RS-232, IEEE-488 and Ethernet
interface as standard, with popular
DMM emulation modes makes systems
integration a simple task.
Software: Transfer data points from your
meter to your PC with the free copy of
FlukeView Forms Basic. To customize
your forms upgrade with FVF-UG.

Dual Display offers versatile graphical


capabilities: The 8845A and 8846A
features a unique graphical display that
can reveal signal quality issues like drift,
intermittent and stability by viewing
the measurement data as a real time
TrendPlot, Histogram or Statistics
using the unique analyze mode.
Wide Measurement Ranges: Resistance
or current has been extended to cover
the widest range possible.

Fluke 8846A

Features
8845A

Use the built-in TrendPlot paperless chart recorder to


graphically identify the extent of drift and intermittent
events in analog circuits

Display
Resolution
Measurement Rate (Rdgs/s)
Continuity / Diode Test
Analytical Functions
Math Functions
USB Device Port
Real Time Clock
Interfaces
Programming Languages/
Emulation Modes
Safety

View results in Histogram mode to reveal stability or


noise problems in analog circuits

8846A
Dual VFD Dot Matrix
6.5 Digits
1000
Yes
Statistics, Histogram, TrendPlot, Limit Compare
NULL, Min/Max, dB/dBm

USB Memory Drive port

Yes
RS232, IEEE-488.2, Ethernet
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII

Specications
(Check the Fluke web for detailed specications)
8845A

Handle even the most demanding measurements with


high accuracy and 6.5 digit resolution

True RMS

Included Accessories
LCI Line Power Cord, Test Lead Set,
Spare Line Power fuse, Programmers Manual/
User Manual on CD-ROM, 884X-USB USB to
RS232 Cable Adapter, FVF-BASIC FlukeView
Forms Software Basic Version.

Function*
Voltage DC
Voltage AC (Freq 300 Hz)
Resistance (2x4 Wire)
Current DC
Current AC (Freq. 3Hz-10kHz)
Freq/Period
Capacitance
Temperature RTD

Resolution

Accuracy* (%)

Range

Resolution

Accuracy* (%)

1000 V
750 V
100 M
10 A
10 A
300 kHz
-

100 nV
100 nV
100
100 pA
10 A
1 Hz
-

0.0035
0.06
0.01
0.05
0.10
0.01
-

1000 V
1000 V
1 G
10 A
10 A
1 MHz
1 nF to 100 mF
-200 to +600

100 nV
100 nV
10
100 pA
100 pA
1 Hz
1 pF
0.001

0.0024
0.06
0.01
0.05
0.10
0.01
1
0.06

* Accuracy =+/- (% of reading)

Size (HxWxD): 88 mm x 215 mm x 293 mm


Weight: 3.6 kg
Three Year Warranty

Recommended Accessories

Ordering Information
Fluke 8845A
6.5 Digit Precision Multimeter
Fluke 8845A/SU 6.5 Digit Precision
Multimeter (software + cable)
Fluke 8846A
6.5 Digit Precision Multimeter
Fluke 8846A/SU 6.5 Digit Precision
Multimeter (software + cable)
Calibration & Service agreements

8846A

Range

www.chorus.ro
884X-case
Hard case

TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads

TL2X4W-PT II
2x4 Wire Ohms Test
lead 2mm Probe Tip

884X-512M
USB Memory 512M

FVF-UG
FlukeView Forms
Software Upgrade

21

8808A 5.5 Digit Multimeter


Versatile multimeter for manufacturing,
development and service applications

Fluke 8808A

Manufacturing test, R&D, development


and service applications demand
performance and flexibility from a
bench meter. The Fluke 8808A delivers a
wide variety of measurement functions,
including volts, ohms, and amps, plus
frequency - all at superior accuracy and
resolution with a basic V dc accuracy of
0.015 %.
Measure sensitive leakage current: The
Fluke 8808A includes two low impedance
low current ranges for measuring
sensitive leakage currents (i-Leakage).

The Fluke 8808A includes two low impedance low


current ranges for measuring sensitive leakage
currents

Use setup keys (S1-S6) for fast access to repetitive


measurements. Setups can include limit compare mode
with pass/fail indicators

Eliminate production mistakes: The


8808A has a limit compare mode with
built in display enunciators that clearly
show whether a test is within or out of
limits.
Perform 4-wire measurements with
only two leads: Patented split terminal
jacks for 2x4 Ohms function allow you
to perform precise 4-wire low ohms
measurements with only two leads
instead of four. Optional test lead
accessories are available to enable you
to establish a 4-wire connection even in
tight spaces or on surface mount devices.

Perform routine manufacturing


functional tests with consistency:
Use setup keys (S1 S6) for fast access to
repetitive measurements. Operators no
longer need to press multiple buttons to
make routine measurements.

Features
8808A
VFD multi segment
5.5 digits
V ac, V dc, I dc, I ac, , Cont, Diode
2X4 Wire Ohms, Freq, i-Leakage
Yes
Limit Compare
dBm, dB, Min, Max
RS-232, USB via optional adapter
Simplified ASCI, Fluke 45
CAT I 1000 V, CAT II 600 V

Display
Resolution
Measurements
Advanced Measurements
Continuity / Diode Test
Analytical Functions
Math Functions
Interfaces
Programming Languages/Modes
Safety Rating

Specications
(Check the Fluke web for detailed specications)
Functions
Voltage DC
Voltage AC
(Freq. 10 Hz to 100 kHz)
Resistance (2x4 Wire)

Dual Display

True RMS

Range
200 mV to 1000 V
200 mV to 750 V

1 V
1 V

Accuracy*
0.015
0.2

200 to 100 M

1 m

0.02

Current DC

200 A to 10 A

1 nA

0.02

Current AC
(Freq. 20 Hz to 2 kHz)
Freq. Period

20 mA to 10A

0.1 A

0.3

20 Hz to 1 MHz
(Freq. only)

0.1 mHz

0.01

Included Accessories

* Accuracy = +/- (% of reading)

LCI Line Power Cord, Test Lead Set, Spare Line


Power fuse, 884X-USB USB to RS232 Cable
Adapter, FlukeView Forms Software Basic
Version, Programmers Manual/User Manual
on CD-ROM.

Size (HxWxD): 88 mm x 217 mm x 297 mm


Weight: 2.1 kg
Three year Warranty

Recommended Accessories

Ordering Information
Fluke 8808A
Fluke 8808A/SU

22

5.5 digit multimeter


5.5 digit multimeter,
(software & cable)
5.5 digit multimeter,
2X4W Test Lead Kit

www.chorus.ro
Fluke 8808A/TL

Resolution

TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads

884X-case
Hard case

TL2X4W-PT II
2x4 Wire Ohms Test
lead 2mm Probe Tip

884X-short
4-Wire Short

FVF-UG/SC4/SC5
FlukeView Forms
Software

Clamp Meters and


Electrical Testers
The ergonomic clamp meters feature wide opening jaws for safe, fast
non-contact current measurement. The Fluke leakage clamp meter is
ideal for non-invasive checks of insulation resistance.
The range of electrical testers includes two-pole testers for taking quick
measurements in tight spaces, phase rotation indicators to take the
guess work out of checking phase/motor rotation, a multipurpose cable
locator and handy voltage alerts.
The new Fluke iFlex flexible current probes expand the measurement
range of select Fluke meters to 2500 A ac and allow technicians to reach
crowded spaces.

www.chorus.ro

23

Measurements
AC current
AC volts
Resistance
Continuity
DC Volts
DC current
True-rms
Frequency
AC + DC voltage
AC + DC current
Min/Max/Avg
Temperature
Capacitance
Special features
Inrush current mode
Low Pass filter
Harmonics, power, data logging
18-inch iFlex Flexible Current Probe
10-inch iFlex Flexible Current Probe
Remote display
Flashlight/torch
Display
Display hold
Backlight
Graphing display
Specifications
Jaw opening
Current range ac rms
Accuracy ac current (50/60 Hz)

24

Resistance range
Frequency measurement range
Unit power
Auto off
Warranty and safety
Warranty (years)
Category ratings (EN61010-1)

0 to 400

2
CAT III 600 V

2
CAT III 600 V

3
CAT III 600 V

0 to 6000

2%
5 counts

0 to 400

0 to 600.0 V

1%
5 counts

2%
5 counts

0 to 600.0 V

2%
5 counts

True-rms
0 to 200 A

2%
5 counts

0 to 6000

1%
5 counts

0 to 600.0 V

1,5 %
5 counts

0 to 600.0 V

2%
5 counts

True-rms
0 to 600.0 A

2%
5 counts

34 mm
0 to 600.0 A

Optional
Optional

0 to 6000
500 Hz

1%
5 counts

0 to 600.0 V

1,5 %
5 counts

0 to 600.0 V

2%
5 counts

True-rms
0 to 600.0 A

2%
5 counts

34 mm
0 to 600.0 A

Optional
Optional

0 to 60 k
500 Hz

1%
5 counts

0 to 1000 V

1,5 %
5 counts

0 to 1000 V

2%
5 counts

True-rms
0 to 999.9 A

2%
5 counts

34 mm
0 to 999.9 A

Included
Optional

O
O

O
O

O
O

376

375

0 to 60 k
500 Hz

1%
5 counts

0 to 1000 V

1,5 %
5 counts

0 to 1000 V

2%
5 counts

True-rms
0 to 999.9 A

2%
5 counts

34 mm
0 to 999.9 A

Included
Optional

381

Industrial electrical

0 to 9999

1%
5 counts

0 to 600.0 V

1%
5 counts

600.0 V

1%
5 counts

True-rms
0 to 200 A

2%
5 counts

30.5 mm
0 to 600.0 A

902

HVAC/R

5 to 1000 Hz

1,5 %
5 counts

True-rms
0 to 2000 A

1.5 %
5 counts

58 mm
0 to 1400 A

0 to 400 k
5 to 1000 Hz

1%
5 counts

0 to 1000 V

1%
5 counts

0 to 600.0 V

1,5 %
5 counts

True-rms
0 to 2000 A

1.5 %
5 counts

58 mm
0 to 1400 A

High end industrial,


utility
353
355

500 Hz

True-rms

3%
5 counts

7.5 mm coil
0 to 2500 A

iFlex
accessory
i2500-10/
i2500-18

Averaging

1%
5 counts

40 mm
0 to 60 A

Leakage
360*

3
3
3
3
3
3
3
3
3
1
CAT III 600 V, CAT III 1000 V, CAT III 1000 V, CAT III 1000 V, CAT III 1000 V, CAT III 600 V CAT III 1000 V, CAT III 1000 V, CAT III 1000 V, CAT III 300 V
CAT IV 300 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT IV 600 V
CAT IV 600 V CAT IV 600 V CAT IV 600 V

0 to 6000

1%
5 counts

0 to 600.0 V

1%
5 counts

0 to 600.0 V

True-rms

2%
5 counts

32 mm
0 to 600.0 A

18 mm
0 to 200.0 A

374

373

General purpose

0 to 600.0 V

1.2 %
5 counts

1.2 %
5 counts

Voltage range dc
Accuracy dc voltage

0 to 600.0 V

0 to 600.0 V

Voltage range ac
Accuracy ac voltage

Averaging

1.8 %
5 counts

1.8 %
5 counts

Averaging

25.4 mm
0 to 400.0 A

25.4 mm
0 to 400.0 A

AC Response
Current range dc
Accuracy dc current

www.chorus.ro

365

Residential/commercial
electrical
321
322

Clamps Selection Guide

381 Remote Display True-rms


AC/DC Clamp Meter with iFlex
New
All the bells and whistles

True RMS

The Fluke 381 Clamp Meter combines


iFlex flexibility with remote reading
capability for the ultimate in innovation
and safety.
Remote display reads measurements
up to 30 feet away
iFlex flexible current probe
included, 18-inch circumference
2500 A ac current measurement
with iFlex
1000 A ac and dc current measurement
with fixed jaw
1000 V ac and dc voltage
measurement
Frequency measurement to 500 Hz
60 k resistance measurement
Min/Max/Avg and inrush recording
CAT IV 600 V, CAT III 1000 V
Three-year warranty
See specifications chart on page 24.

365 Detachable Jaw


True-rms AC/DC Clamp Meter
New

Where rugged meets reliable


The Fluke 365 Clamp Meter offers a
small, detachable jawwith four feet of
coilthat makes it easy to take and read
measurements in tight or hard-to-reach
places.
200 A ac and dc current measurement
600 V ac and dc voltage measurement
6000 resistance measurement
Built-in flashlight
Large, easy-to-read backlight display
Three-year warranty
True RMS

See specifications chart on page 24.

Included Accessories
18-inch iFlex Flexible Current Probe (Fluke
381), test leads, soft carrying case, instruction
card, safety information sheet, two AA
alkaline batteries.

Recommended Accessories

Ordering Information

www.chorus.ro
Fluke 381
Fluke 365

Remote Display True-rms


AC/DC Clamp Meter with iFlex
Detachable Jaw True-rms
AC/DC Clamp Meter

TL223-1
See page 122

TL175
See page 124

25

370 Series Clamp Meters


New
Be ready for anything
Our new family of true-rms clamp meters
provides a range of state of-theart features to meet even the most
demanding job requirements.
All four of the new clamp meters have
improved base features such as a large,
backlit display, true-rms standard, CAT IV

safety rating and a durably constructed


body. Additionally, the 376, 375 and 374
are compatible with the iFlex flexible
current probe (included with the 376,
sold separately for the 375 and 374), and
provide increased measurement readings
to 1000 A and 1000 V ac and dc.

Features

Fluke 376
(with i2500)

373

374

375

376

True-rms

AC current

AC voltage

Resistance

Continuity

DC volts

DC current

Frequency
Low pass filter

18-inch iFlex Flexible Current Probe

Optional

Optional

Included

10-inch iFlex Flexible Current Probe

Optional

Optional

Optional

Inrush current mode

Specications
Functions

Range

373

374

375

Current AC

0 to 600.0 A

2% 5 counts

2% 5 counts

2% 5 counts

Current DC

0 to 600.0 A

2% 5 counts

2% 5 counts

Voltage AC

0 to 600.0 V

1% 5 counts 1.5% 5 counts 1.5% 5 counts 1.5% 5 counts

Voltage DC

0 to 600.0 V

1% 5 counts

1% 5 counts

1% 5 counts

0 to 6000

0 to 6000

0 to 6000

32 mm

34 mm

34 mm

34 mm

750 MCM

750 MCM

750 MCM

750 MCM

500 Hz

500 Hz

0 to 999.9 A

Fluke 375

Fluke 374

Fluke 373

2% 5 counts

0 to 999.9 A

2% 5 counts

0 to 1000 V
Resistance range
Jaw opening
Max. wire size

376

1% 5 counts

Frequency measurement range

0 to 60 k

iFlex Flexible Current Probe


Fluke i2500

True RMS

Included Accessories
18-inch iFlex flexible current Probe (Fluke
376), test leads, soft carrying case, instruction
card, safety information sheet,
two AA alkaline batteries.

The new Fluke iFlex flexible current probes expand the measurement range of select
Fluke meters to 2500 A ac and allow technicians to reach crowded spaces.
Expands the measurement range to 2500 A ac while providing increased display
flexibility, ability to measure awkward sized conductors and improved wire access
Compatible to Fluke 374, 375, 376 and 381
CAT IV 600 V, CAT III 1000 V
7.5 mm coil diameter allows measurement in tight spaces
Ergonomic design allows easy operation with one hand
1.8 m (6 ft) cable
Three-year warranty

Ordering Information
Fluke 376

True-rms AC/DC Clamp Meter


with iFlex
Fluke 375 True-rms AC/DC Clamp Meter
Fluke 374 True-rms AC/DC Clamp Meter
Fluke 373 True-rms AC Clamp Meter
i2500-10 iFlex Flexible Current Probe 25 cm (10 in)
i2500-18 iFlex Flexible Current Probe 45 cm (18 in)

26

www.chorus.ro

Recommended Accessories

TL223-1
See page 122

AC285
See page 124

TL175
See page 124

320 Series Clamp Meters


Get more done

The Fluke 321 and 322 are designed


to verify the presence of load current,
ac voltage and continuity of circuits,
switches, fuses and contacts. These small
and rugged clamp meters are ideally
suited for current measurements up to
400 A in tight cable environments.
Precised measurements with 1.8 % basic
accuracy

Resolution up to 0.01 A and 0.1 V


Measures ac current 40.00 A/400.0 A
Measures ac and dc volts to 600 V
Resistance measurement to 400
Continuity for quick checking of shorts

See specifications chart on page 24


for details per model.

Features
321

322

902

AC current

AC voltage

Resistance

Continuity

True-rms

DC volts

Fluke 322

Fluke 321

DC current

Min/Max/Avg

Temperature

Capacitance

902 True-rms HVAC Clamp Meter


Just for our HVAC pros
HVAC (heating, ventilation, air
conditioning) technicians require a service
tool that can consistently keep up with
their demands. The Fluke 902 expands the
existing line of quality Fluke clamp meters
by delivering the features necessary
to diagnose and repair HVAC systems.
Combined with true-rms technology
and a CAT III 600 V rating, the Fluke 902
helps technicians do their jobs safely and
accurately.
Designed for HVAC applications with
capacitance, dc current (A), and
temperature measurements

Small body and jaws fit perfectly in your


hand and into tight places
Handy Display Hold button keeps
measurements on the display
Meter controls are positioned so current
measurements can be done with one
hand (index finger on clamp opening
lever and thumb on rotary switch)
Three-year warranty
See specifications chart on page 24.

Specications
Functions

Range

Current AC

0 to 400.0 A

321

322

0 to 600.0 A

True RMS

Current DC

0 to 200.0 A

Voltage AC

0 to 600.0 V

Voltage DC

0 to 600.0 V

2% 5 counts
1% 5 counts
1.2% 5 counts 1.2% 5 counts

600.0 V

Fluke 902

902

1.8% 5 counts 1.8% 5 counts

1% 5 counts
1% 5 counts

1% 5 counts
0 to 9999

Resistance range

0 to 400

0 to 400

Jaw opening

25.4 mm

25.4 mm

30.5 mm

Max. wire size

500 MCM

500 MCM

750 MCM

Included Accessories

Recommended Accessories

Test leads, temperature probe (Fluke 902), soft


carrying case, instruction card, safety
information sheet, two AA alkaline batteries.

www.chorus.ro
Ordering Information
Fluke 321
Fluke 322
Fluke 902

Clamp Meter
Clamp Meter
True-rms HVAC Clamp Meter

TL223-1
See page 122

TL175
See page 124

LVD2
See page 32

H3
See page 131

27

350 Series AC/DC Clamp Meters


True-RMS, 2000 A Clamp Meters
for industrial and utility applications
Confidently take reliable readings with
the true-rms, Fluke 353/355 Clamp
Meters; the tools of choice for high
current measurement up to 2000 A. The
extra-wide jaw easily clamps around
large conductors, typically found in high
current applications. The rugged design
and CAT IV 600 V, CAT III 1000 V ratings
add an extra element of protection when
taking high-powered measurements.

Accurate peak measurements can be


taken using the in-rush current mode ideal for motors and inductive loads. The
355 also measures voltage and resistance,
making this the most versatile tool
for utilities, electrical contractors and
industrial service technicians.

Features
True-RMS measurements
Display backlight
Motor start-up current
Min/Max/Average
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper

Fluke 353

353

355

O
O
O
O

O
O
O
O
O
O
O

Specications
(Check the Fluke web for detailed specications)
Fluke 355

Functions
Current AC/DC

Range
0-40.00 A
0-400.0 A
0-2000 A; 1400 AC rms

Crest Factor
Voltage AC/DC

0-4.000 V
0-40.00 V
0-400.0 V
0-600 V AC rms
0-1000 V DC
0-400.0
0-4.000 k
0-40.00 k
0-400.0 k
Appr. 30
5.0Hz to 100.0Hz
100.1Hz to 999Hz

Resistance

Continuity beeper
Frequency
True RMS

353
1.5% 15 counts

355
1.5% 15 counts

1.5% 5 counts

1.5% 5 counts

2.4

2.4
1% 10 counts
1% 5 counts

1.5% 5 counts

0.2% 2 counts
0.5% 5 counts

Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries,
users manual
Fluke 355: C43 Soft Meter Case, 6 AA batteries,
TL224 SureGrip Silicone Test Lead Set, TP2
Slim Reach Test Probe Set (2 mm), AC285
SureGrip Alligator Clip Set, users manual

Power Supply:
Battery Life:

6 x 1.5V AA NEDA 15A


or IEC LR6
100 hours (with typical
usage, backlight off)

Size (HxWxD): 300 mm x 98 mm x 52 mm


Jaw opening: 58 mm
Weight: 0.814 kg
Two year warranty

Ordering information
Fluke 353
Fluke 355

28

AC/DC Clamp Meter


AC/DC Clamp Meter

www.chorus.ro

Recommended Accessories

TL223-1 (Fluke 355)


See page 122

L215 (Fluke 355)


See page 123

360 Leakage Clamp Meter


Leakage current measurements with a tough,
pocket sized clamp meter
The Fluke 360 is ideal for non-invasive
checks of insulation resistance.
The unique jaw design eliminates the
influence of adjacent current conductors.
The ergonomic design of the Fluke 360
ensures easy measuring. The measuring
clamp fits into tight spaces and the
wide display angle clearly shows the
measurement result. The data hold
button keeps the measured value on the
display after removing the clamp for the
measured conductor.
The light Fluke 360 offers the widest
range of current measurement for
maintenance professionals and
contractors.

Features
Measurement of leakage protectives
conductor and touch current with a
resolution of 1A
Advanced shielding to ensure accurate
results when measuring near other
conductors
Automatic ranging within the manually
selected mA or A range
Easily viewed measurements on digital
and bargraph display and HOLD when
measuring in hard to see locations
Broad range of measurements currents
up to 60 A for all installation needs
Easy carrying, pocket sized clamp with
wide 40 mm jaw size
Display-Hold for convenience in use
Auto power off with audible warning
buzzer
Conformance to IEC61010 and EMC
standard
Meets all the applications and
performance classes in safety standard
VDE0404-4 and the new VDE0702

Fluke 360

Specications
(Check the Fluke web for detailed specications)
Functions

Range
3mA
30mA
30A
60A
50 and 60Hz

Current AC

Frequency

Resolution
0.001A
0.01mA
0.01A
0.1A

Accuracy
1% 5 counts
1% 5 counts (0~50A)
5% 5 counts (50~60A)

Battery type: 3 Volt Lithium, 90 hours typical


Size (HxWxD): 176 mm x 70mm x 25 mm
Weight: 0.2kg
One Year warranty

Included accessories
Soft carrying pouch and users manual

display: 1.7mA

Ordering information
Fluke 360

leakage
current 0.5mA

Leakage Clamp Meter

www.chorus.ro
ground

leakage current
1.2mA (e.g. via
motor shaft)

29

T100 Series
Voltage and Continuity Testers
The fast and easy solution to voltage,
continuity and phase rotation testing
The fast and easy solution to voltage,
continuity and resistance measurements.
Ideal for site conditions, the 3 models
of the T100 Series 2-pole testers have a
rugged construction and ergonomically
formed housing for perfect handling.
All models offer a patented three-phase
rotation detection system providing
quick phase rotation indication.

Moreover they have a special electrical


torch function for working in low light
level environments and have an ingress
protection rating of IP65. The T100 Series
are compliant with EN 61010-1 and
EN61243-3 requirements.

Fluke T120

Features
T100

Fluke T140

Fluke T100

Display
Led Bargraph
Backlight
Resistance measurement
Switchable load
Voltage test
Optical and acoustical continuity test
Rotary field indication
Single pole test for phase detection
Indication of polarity
Electrical torch function
Probe tip protection
The voltage display also functions when using
discharged - or o batteries

12 LEDs

T120
LCD
12 LEDs

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

T140
LCD
12 LEDs
O
O
O
O
O
O
O
O
O
O
O

Specications

Included Accessories
Two 1.5V batteries and instruction sheet

Voltage AC/DC
Continuity
Frequency
Phase rotation
Resistance measurement
Response time

T100
12 - 690 V
0 - 400 k
0 - 400 Hz
100 to 690 V
< 0.1 s

T120
12 - 690 V
0 - 400 k
0 - 400 Hz
100 to 690 V
< 0.1 s

T140
12 - 690 V
0 - 400 k
0 - 400 Hz
100 to 690 V
Up to 1999
< 0.1 s

Ordering Information
Fluke T100
Fluke T120
Fluke T140

Voltage/Continuity Tester
Voltage/Continuity Tester
Voltage/Continuity Tester

Size (HxWxD): 240 mm x 56 mm x 24 mm


Case: IP65 (water-jet and dust tight protection)
Weight: 180 g
Two year warranty

UK versions are compliant with GS38

Recommended Accessories

30

www.chorus.ro

C33 (T100 Series)


See page 130

T5 Electrical Testers
The fast and easy solution to basic
electrical testing
The Fluke T5 testers let you check
voltage, continuity and current with
one compact tool. Select volts, ohms or
current and the instrument does the rest.
Model T5-600 measures 600 volts
AC/DC, model T5-1000 is designed for
1000 volts. OpenJaw current technology
lets you check current up to 100 A,
without breaking the circuit. The optional
H5 holster keeps the test probes and
leads ready to test and lets you clip the
T5 onto your belt.

Features and Specications

Fluke T5-1000
(incl. TP1-1 test probes)

Fluke T5-600
(incl. TP1-1 test probes)

T5-600
1000
O
O
O
600 V
600 V
100 A
1000
600V CAT III

Display Count
Automatic Selection
Continuity and Bleeper
Sleep Mode
AC Voltage
DC Voltage
AC Current
Resistance
Safety range

Battery life: 400 hours


Size (HxWxD):
203 mm x 51 mm x 30.5 mm

Fluke T5-H5-1AC Kit

Fluke T5-600/62/1AC-E Kit

T5-1000
1000
O
O
O
1000 V
1000 V
100 A
1000
1000 V CAT III / 600 V CAT IV

Weight: 0.38 kg
Two year warranty

Fluke T5-H5-1AC Kit

Fluke T5-600/62/1AC-E Kit

The ideal kit for busy electrical


contractors and electricians. The benefits
of a voltage and current meter and noncontact voltage detector all in one kit. A
holster for the T5 is also included.

This kit is designed to help electricians


and HVAC technicians solve problems
quicker. Test first for overheated electrical
devices using an IR thermometer; then
use elecrtrical test tools to find out more
about the problem.

Kit includes:
- Fluke T5-1000
- H5 holster
- Free Fluke 1AC-II

Kit includes:
Fluke T5-600
Fluke 62
Fluke 1AC II
C115

Included Accessories
2 TP38 detachable probe (CAT III),
2 TP1-1 detachable probe (CAT II),
(detachable GS38 probes for the UK)
and instruction sheet

Ordering Information
Fluke T5-600
Fluke T5-1000
Fluke T5-H5-1AC Kit

Electrical Tester
Electrical Tester
Electrical Tester with
holster and IAC
Fluke T5-600/62/1AC-E Electrical Tester,
IR Thermometer,
Voltage Detector Kit

www.chorus.ro

Recommended Accessories

H5
See page 131

ACC-T5-Kit
See page 123

AC285
See page 124

31

1AC II/2AC Volt Alerts


LVD1/LVD2 Volt Lights
Fluke 1AC II VoltAlert
The Fluke VoltAlert AC voltage detector is
very easy to use just touch the tip to a
terminal strip, outlet or cord. When the tip
glows red and the unit beeps, you know there
is voltage on the line.
It continually tests its battery and its circuit
integrity with a periodic double flash visual
indication.
Highest safety rating: CAT IV 1000 V
Detects voltage without metallic contact

Fluke 1AC II

Fluke 2AC VoltAlert

2AC VoltAlert
2AC is the latest addition to the VoltAlert ac
non- contact voltage tester family from Fluke
and is designed to be pocket-sized and easy
to use. The 2AC tests for energized circuits
and defective grounds, whether its for an
electrician on the factory floor or the do-ityourselfer around the house. The tip of the
pocket-sized tester will glow red when within
close proximity of an outlet, terminal strip, or
power cord where voltage is present.
Voltage detection from 200 to 1000 V ac,
suitable for a wide range of residential,
commercial and industrial needs.
NEW! Always on, using special low power
circuitry to sustain battery life and ensure
your 2AC is always ready.
NEW! Innovative Battery Check button
function ensures battery is in good
condition*
Category IV 1000 V overvoltage rated
product for best in class user protection
Integrated clip design, optimized for pocket
storage
Powered by 2x AAA batteries (included)
Fluke ruggedness and reliability
Two-year warranty storage.
Powered by 2x AAA batteries (included)Fluke reliability and ruggedness, Two-year
warranty.

Operating range: 200 1000 V AC


Batteries: Two AAA Alkaline
Size (H): 148 mm
Two Year Warranty

Fluke 1AC II VoltAlert 5-pack


Buy 4 get 1 FREE

Operating range: 200 1000 V AC


Batteries: Two AAA Alkaline
Size (H): 148 mm
Two Year Warranty

Fluke 2AC VoltAlert 5-pack


Buy 4 get 1 FREE

Features

LVD2

LVD2 Volt Light


Combines bright light and voltage detection
in one pen style design
Dual sensitivity
Detects voltage from 90 V to 600 V AC
Blue light means youre close
Red light means youre at the source
Rated to CAT IV 600 V

Voltage Detection

Battery Included

Battery Check

On/Off Button

LVD1

Ordering Information
Fluke 1AC II
Fluke 1AC II
Fluke 2AC
Fluke 2AC
LVD2
LVD1

32

Volt Alert
Volt Alert (5-pack)
Volt Alert
Volt Alert (5-pack)
Volt Light
Volt Light

Voltbeat

LVD1 Volt Light


Dual sensitivity voltage detector
Detects voltage from 40 V to 300 V AC
Blue light means youre close
Red light means youre at the source
Comes with a versatile clip to secure light
to pocket, hat or even panel door

www.chorus.ro

Audible/Silent

Dual Sensitivity

LED Flashlight

2AC
1AC-II
200-1000 V AC 200-1000 V AC
CAT IV 1000 V CAT IV 1000 V

LVD2
90-600 V AC
CAT IV 600 V

9040/9062
Phase Rotation Indicators
Take the guess work out of phase/motor
rotation measurements
Fluke 9040

Fluke 9062

The Fluke 9040 is effective for measuring


phase rotation in all areas where
three-phase supplies are used to feed
motors, drives and electrical systems.
The Fluke 9040 is a rotary field indicator
and can provide clear indication of the
3 phase via an LCD display and the
phase rotation direction to determine
correct connections. It allows rapid
determination of phase sequence
and has a voltage (up to 700 V) and
frequency range suitable for commercial
and industrial applications. Test probes
supplied with the instrument have a
variable clamping range for safe contact,
especially in industrial sockets.

The unique Fluke 9062 provides rotary


field and motor rotation indication with
the benefits of contact-less detection.
Purpose made for commercial and
industrial environments, the Fluke 9062
provides rapid indication of 3 phase
rotation using test leads supplied or can
be used to determine motor rotation on
synchronous and asynchronous 3 phase
motors. The contact-less detection is
ideal for use on motors where the shaft is
not visible.
Test probes supplied with the instrument
have a variable clamping range for safe
contact, especially in industrial sockets.

Fluke 9040

Features
9040
Via LCD
O

3 phase indication
Indication of phase rotation
Indication of motor rotation direction
Contact free determination of the rotation direction of running motors
Clear LCD display
No battery required

9062
Via LED
O
O
O

O
O

Fluke 9062

9040:

Specications

9062:

Voltage range
Phase display
Frequency range
Operating time

Size (HxWxD) Fluke 9040:


124 mm x 61 mm x 27 mm
Size (HxWxD) Fluke 9062:
124 mm x 61 mm x 27 mm

9040
40 - 700 V
15 - 400 Hz
Continuous

9062
Up to 400 V
120 - 400 V AC
2-400 Hz
Continuous

Power supply 9040: from unit under test


Power supply 9062: 1 x 9V
Weight 9040: 0.20 kg
Weight 9062: 0.15 kg
Two Year Warranty

Fluke 9062 Applications

Included Accessories
Fluke 9040: Alligator clips - black (3)
Standard test probes - black (3)
Flexible test probes - black (3)
Fluke 9062: Alligator clips - black (3)
Flexible test probes - black (3)
Test leads - black (3)

Ordering Information
Fluke 9040
Fluke 9062

Phase Rotation Indicator


Motor and Phase Rotation
Indicator

Determine the presence of


phase sequence of multiphase
electrical supplies.

www.chorus.ro

Determine the rotation of


running motors simply by
placing the instrument on
the motor casing.

Check the correct rotation of


motors prior to connection.

Recommended Accessories

TLK290
See page 123

TLK291
See page 123

C25
See page 130

33

2042 Cable Locator


The multipurpose solution to cable location
The Fluke 2042 is a professional general
purpose cable locator. It is ideal for
tracing cables in walls and underground,
locating fuses/breakers on final circuits
and locating interruptions and shortcircuits in cables and electrical floor
heating systems.
It can also be used for tracing metallic
water and heating pipes. The unit is
supplied as a complete kit comprising of
a transmitter and receiver in a purposemade carry case. The receiver also
incorporates a torch function for working
in dimly lit locations.

Transmitter

Receiver

Fluke 2042

Receiver with a backlight LCD-display


for level of receiving signal, code
of receiving signal and live voltage
indication
Automatic or manual adjustment of
receiving signal sensitivity
Switchable acoustic receiving signal
Auto-Power-Off
Additional torch lamp function for
working in dark environments
Additional transmitters are available
for extension or to distinguish between
several signals.

For all applications (live or dead cables)


without additional instruments
Set includes a transmitter and a
receiver
Proven digitally coded sender signal
guarantees clear signal identification
Transmitter with LCD-display for
transmitting level, transmitting code
and external voltage

Specications

Transmitter
12V, 50V,120V, 230V, 400V
0..60 Hz
125 kHz
Up to 400V AC/DC

Voltage Measurement Range


Frequency Range
Output signal
Voltage
Tracing depth cable location

Receiver

0...2.5m wall/underground
cables
0...0.4m

Main voltage detection

Batteries Transmitter: 6 pc Batteries 1.5V


Batteries Receiver: 1 pc Battery 9V
Size (HxWxD) Transmitter:
190 mm x 85 mm x 50 mm
Size (HxWxD) Receiver:
250 mm x 65 mm x 45mm
Weight Locator: 0.45 kg
Weight Receiver: 0.36 kg
Two Year Warranty

Fluke 2042 applications

Included Accessories
TL27 Heavy Duty Test Lead Set (2)
TP74 Lantern Tip Test Probe Set
AC285 Alligator Clip Set
Soft carrying case
Hard case

Ordering Information
Fluke 2042
Fluke 2042T

Location of fuses/breakers
and assignment to circuits

Cable Locator
(transmitter + receiver)
Cable Locator Transmitter

Tracing of underground
cables (max. depth 2.5 m)

Precise location of cable


interruptions with additional
transmitter

Recommended Accessories

34

www.chorus.ro

Fluke 2042T

Insulation Testers and


Earth Ground Testers
With a 10kV insulation resistance tester and a range of compact handheld instruments, we offer a solution for every troubleshooting and
preventive application.
Two of the digital hand-held insulation testers also include full-featured
multimeters.
The Fluke Earth Ground Testers can perform all four types of earth
ground measurement, including stakeless testing with earth ground
loop resistances using only clamps.

www.chorus.ro

35

Insulation Tester
Selection Guide

InstallationTest Functionality
Test voltages
Insulation Resistance Test Range
Polarization Index/Dielectric
Absorption Ratio
Auto Discharge
Time Ramp test (Breakdown)
Pass/Fail Comparison
Estimated Number of
Insulation resistance Tests
Voltage > 30V Warning
Memory
Remote Test Probe
Lo Ohms
Display
Continuity
Multimeter Functionality
AC/DC Volts
Current
Resistance
Temperature (contact)
Lo-Pass Filter
Capacitance
Diode Test
Frequency
MIN/MAX
Other
Hold/Lock
Backlight

1577

1587

1587T

1503

1507

1550C

1555

500V, 1000V

50V, 100V, 250V,


500V, 1000V

50V, 100V

500V, 1000V

50V, 100V, 250V,


500V, 1000V

250V, 500V, 1000V,


2500V, 5000V

250V, 500V, 1000V,


2500V, 5000V, 10000V

0.1M - 600M

0.01 M - 2G

0.01M - 100M

0.1M - 2G

0.01M - 10G
O

200K - 1T
O

200K - 2T
O

O
O

O
O

1000

1000

1000

1000

O
1000

1000 @ 5000 V

1000 @ 10000 V

O
(99 locations)

O
(99 locations)

Digital LCD

Digital LCD

Digital LCD

O
O
Digital LCD

O
O
Digital LCD

(200mA)

(200mA)

O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O

O
O

O
O

O
O

Digital LCD / Analog Digital LCD / Analog


Bar Graph
Bar Graph

O
O

(Fluke View Forms (Fluke View Forms


Basic)
Basic)
3
3

Software
Warranty (in years)
Battery

3
4 AA (NEDA 15A or
IEC LR6)

3
4 AA (NEDA 15A or
IEC LR6)

3
4 AA (NEDA 15A or
IEC LR6)

1
4 AA (NEDA 15A or
IEC LR6)

1
4 AA (NEDA 15A or
IEC LR6)

Rechargeable

Rechargeable

Buy a Fluke 1587 Combo Kit and save


Fluke 1587/ET Advanced Electrical
Troubleshooting Kit

Fluke 1587/MDT Advanced Motor


& Drive Troubleshooting Kit

This kit contains:


Fluke 1587 Insulation Multimeter
Fluke 62 Mini Infrared Thermometer
i400 Current Clamp

This kit contains:


Fluke 1587 Insulation Multimeter
Fluke 9040 Phase Rotation Indicator
i400 Current Clamp

Perform insulation tests with the Fluke


1587 plus a wide-range of DMM tasks with
confidence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current
without breaking the circuit. Check for hot
spots and measure temperature with the
Fluke 62 Mini non-contact thermometer.

Perform insulation tests with the Fluke


1587 plus a wide-range of DMM tasks with
confidence and ease. Use the i400 with your
Fluke 1587 to accurately measure AC current
without breaking the circuit. Check the phaserotation of three-phase motors easily and
safely with the Fluke 9040.

Fluke 1587/ET

36

www.chorus.ro
Fluke 1587/MDT

1577/1587
Insulation Multimeters
Two powerful tools in one
The Fluke 1587 and 1577 Insulation
Multimeters combine a digital insulation
tester with a full-featured True RMS
digital multimeter in a single compact,
handheld unit, which provides maximum
versatility for both troubleshooting and
preventive maintenance.

Whether you work on motors, generators,


cables, or switch-gear, the
Fluke 1587/1577 Insulation Multimeters
are ideally suited to help you with your
tasks.
The Fluke 1587T is specially designed for
the telecom environment.

Features
Multimeter Features
True RMS Voltage and Current for accurate measurements
Digital display counts
Autorange and manual range for easy testing.
Selectable filter for accurate voltage and frequency measurements on motor
drives
Min Max Recording, Diode test, temperature, capacitance & frequency
measurement for maximum flexibility.

Fluke 1577

1577
O
6000
O

Insulation features
User selectable test voltages for many applications
Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Live circuit detection prevents insulation test if voltage > 30V is detected for
added user protection

Fluke 1587
Fluke 1587T

General features
Auto Power off to save batteries
Large display with backlight
Input Alert to warn for incorrect connections
Continuity

1587
O
6000
O
O

1587T
O
6000
O
O

O
O
O

O
O
O
O
O

O
O
O

O
O
O
O

O
O
O
O

O
O
O
O

Insulation Specications
Functions
Measurement range
Test voltages

1577
0.1M to 600M
500V, 1000V

Test voltage accuracy


Insulation test current
Auto discharge

+ 20%, -0%
1mA nominal
Discharge time < 0.5s
for C = 1 F or less
Up to 1 F load

Maximum capacitive load

1587
0.01M to 2G
50V, 100V, 250V, 500V,
1000V
+ 20%, -0%
1 mA nominal
Discharge time <0.5s
for C = 1 F or less
Up to 1 F load

1587T
0.01M to 100M
50V, 100V
+ 20%, -0 %
1 mA nominal
Discharge time <0.5s
for C = 1 F or less
Up to 1 F load

Multimeter Specications

Included Accessories
C101 Rugged, utility hard case
TL224 SureGrip Silicone Test Lead Set
AC285 SureGrip Alligator Clip Set
80BK Integrated DMM Temperature Probe
(Type K)
TP165X Remote Test Probe

Functions
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature

Battery life:

Maximum
1000V
1000V
400mA
400mA
50.0M
9999F
99.99kHz
-40C to +537C

Max. resolution
1 mV
0.1mV
0.01mA
0.01mA
0.1
1 nF
0.01 Hz
0.1C

Meter: 1000 hrs,


Insulation Test: >1000 tests

1577
(0.2% + 2)
(2% + 3)
(1.0% + 2)
(2% + 2)
(1.2% + 2)
-

1587/1587T
(0.09% + 2)
(2% + 3)
(0.2% + 2)
(1.5% + 2)
(0.9% + 2)
(1.2% + 2)
(0.1% + 1)
(1% + 10)

Weight: 0.55 kg
Three Year Warranty

Size (HxWxD):
203 mm x 100 mm x 50 mm

Recommended Accessories

Ordering Information

www.chorus.ro
Fluke 1577
Fluke 1587
Fluke 1587T

Insulation Multimeter
Insulation Multimeter
Insulation Multimeter
(for Telecom)

C25
See page 130

i400
See page 126

TPAK
See page 132

L215
See page 123

TL238
See page 122

37

1503/1507 Insulation Testers


Truly portable insulation resistance testers
When you need a low cost solution to
general purpose insulation testing look
no further than the new Fluke insulation
tester range. The Fluke 1507 and 1503
Insulation Testers are compact, rugged,
reliable and easy to use.

The multiple test voltages on both


models make them ideal for many
troubleshooting, commissioning and
preventive maintenance applications.
Additional features like the remote
probe save both time and money when
performing tests.

Features
1503
O

User selectable test voltages for many applications


Additional test voltages 50V, 100V, 250V
Special remote control probe for easy and safe measurements
Auto-discharge of capacitive voltage for added user protection
Live circuit detection prevents insulation test if voltage > 30 V
is detected for added user protection
Save both time and money with Automatic calculation of
Polarization Index and Dielectric Absorption Ratio
Auto Power off to save batteries
Large display with backlight
Continuity function (200 mA)
Compare function (pass/fail) for fast repetitive tests

Fluke 1503

O
O
O

1507
O
O
O
O
O
O

O
O
O

O
O
O
O

Fluke 1507

Specications
Insulation specifications
Insulation test range
Test voltages
Test voltage accuracy
Insulation test current
AC/DC Voltage measurement
Resistance measurement range
Auto discharge

1503
0.1 M to 2 G
500 V, 1000 V
+ 20 %, - 0 %
1mA nominal
600 V (0.1 V resolution)
0.01 to 20 k
Discharge time < 0.5 second
for C = 1 F or less
Up to 1 F
> 4V ,< 8V
> 200 mA

Maximum capacitive load


Open circuit test voltage
Short circuit current

Battery life: Insulation Test: > 1000 tests


Size (HxWxD):
203 mm x 100 mm x 50 mm

Weight: 0.55 kg
One Year Warranty

Fluke 1503/1507 Applications

Included Accessories
TP165x
TL224
TP74

1507
0.01 M to 10 G
50 V, 100 V, 250 V, 500 V, 1000 V
+ 20 %, - 0 %
1mA nominal
600 V (0.1 V resolution)
0.01 to 20 k
Discharge time < 0.5 second
for C = 1 F or less
Up to 1 F
> 4V ,< 8V
> 200 mA

Remote Test Probe


SureGrip Silicone Test Lead Set
Lantern Tip Test Probe Set
Alligator clips

Ordering Information
Fluke 1503
Fluke 1507

Insulation Tester
Insulation Tester

Insulation test at a
distribution panel

Wiring test in a small


distribution box
all in one spot

Recommended Accessories

www.chorus.ro
C101
See page 131

38

PAK
See page 132

TLK 225
See page 123

AC285
See page 122

L210
See page 133

1555/1550C
Insulation Resistance Testers
New

Digital insulation testing up to 10kV


The new 1555 and redesigned Fluke
1550C insulation resistance testers
offer digital insulation testing up to
10kV, making them ideal for testing a
wide range of high voltage equipment
including switchgear, motors, generators
and cables. Fluke insulation testers can
now conduct the entire range of test
voltages specified in IEEE 43-2000 with a
best in class, 3-year warranty and CAT IV
600 V safety rating. With measurement
storage and PC interface, the 1555 and
1550C are perfect tools for preventative
or predictive maintenance programs
designed to identify potential equipment
failures before they occur.

Fluke 1555

Fluke 1550C

Selectable test voltages in 50 V steps


from 250 to 1000 V, and 100 V steps
above 1000 V
Measurements can be stored in up to 99
memory locations, with each location
assigned a unique, user defined, label
for easy recall
Long battery life gives the user over 750
tests between charges
Automatic calculation of Dielectric
Absorption (DAR) and Polarization
Index (PI) with no additional setup
Guard system eliminates the effect
of surface leakage current on highresistance measurements
Large digital/analog LCD for easy
viewing
Capacitance and leakage current
measurement
Ramp function for breakdown testing
Resistance measurements up to 2T
Timer settings up to 99 minutes for
timed tests
3-year warranty

Test voltages up to 10 kV (1555)


provides solutions for all applications
CAT III 1000 V, CAT IV 600 V safety rating
Voltage breakdown detection alerts the
user that voltage is present and gives
the voltage reading up to 600 V ac or dc
for increased user safety

Specications
(Check the Fluke web for detailed specications)
Test voltage (dc)

Range

Accuracy ( reading)

250 V

< 200 k
200 k to 5 G
5 G to 50 G
> 50 G
< 200 k
200 k to 10 G
10 G to 100 G
> 100 G
< 200 k
200 k to 20 G
20 G to 200 G
> 200 G
< 200 k
200 k to 50 G
50 G to 500 G
> 500 G
< 200 k
200 k to 100 G
100 G to 1 T
> 1 T
< 200 k
200 k to 200 G
200 G to 2 T
> 2 T

unspecified
5%
20 %
unspecified
unspecified
5%
20 %
unspecified
unspecified
5%
20 %
unspecified
unspecified
5%
20 %
unspecified
unspecified
5%
20 %
unspecified
unspecified
5%
20 %
unspecified

500 V

1000 V

2500 V

Included accessories
Test Cables with Alligator Clips (red, black, green)
Infrared adapter with interface cable
FlukeView Forms Basic CD-ROM
AC Power Cord
Soft Carrying Case (base models only)
English Manual
Users Manual on CD-ROM
Quick Reference Card
Software License Agreement
Registration Card
FlukeView Forms Installation Guide
USB-IR Cable Installation Guide
IP67 Hard Case (kit only)
Certificate of Calibration (kit only)
Ruggedized Alligator Clips (kit and 1555 only)

5000 V

10000 V (1555 only)

Bar Graph Range

0 to 1 T & 0 to 2 T (1555 only)

Insulation test voltage accuracy

-0 %, +10 % at 1 mA load current

Induced ac mains current rejection

2 mA maximum

Charging rate for capacitive load

5 seconds per F

Discharge rate for capacitive load

1,5 s/F

Leakage current measurement


Capacitance measurement
Timer

Software specications
Fluke ViewForms basic software requires a
PC running Windows 2000, Windows XP and
Windows Vista.

Live circuit warning

Range

Accuracy

1 nA to 2 mA

(5% + 2 nA)

0,01 uF to 15,00 F

(15% rdg + 0,03 F)

Range

Resolution

0 to 99 minutes
Warning range

Setting: 1 minute
Indication: 1 second
Voltage accuracy

30 V to 660 V ac/dc, 50/60 Hz

(15% + 2 V)

Optional Accessories
TL1550EXT

25 Foot Extended Test Lead Set

Temperature (operating):
-20 C to 50 C ( -4 F to 122 F)
Temperature (storage):
-20 C to 65 C (-4 F a 149 F)
Humidity: 80 % to 31 C decreasing linearly to
50 % at 50 C

www.chorus.ro
Ordering information
Fluke 1550C 5 kV
Fluke 1555 10 kV
Fluke 1550C/Kit 5 kV
Fluke 1555/Kit 10 kV

Insulation Tester
Insulation Tester
Insulation Tester Kit
Insulation Tester Kit

Enclosure sealing: IP40


Altitude: 0 to 2000 m
Power: 12 V lead-acid rechargeable battery,
Yuasa NP2.8-12
Dimensions: 170 mm x 242 mm x 330 mm
Weight: 3,6 kg (7,94 lb)
3-year warranty

39

1620 Series
Earth Ground Testers GEO
Advanced technology for all your earth
ground testing applications

Fluke 1623

The new Fluke 1620 Series Earth Ground


Testers not only measure ground
resistance using the classic fall of
potential test but also enable time
saving testing using the selective and
stakeless methods. Selective testing
does not require the electrode under
test to be disconnected during the
measurement, thus increasing safety.
The simple stakeless method quickly
checks ground connections using two
current transformers (probes) clamped
around the ground conductor under test.
Offering one-button simplicity, the 1623
is an all-in-one earth ground tester, while
the 1625 has extra versatility for more
demanding applications.

Earth ground resistance and soil


resistivity should be measured
when:
Designing earth ground systems
Installing new ground system and
electrical equipment
Periodically testing ground and
lightning protection systems
Installing large electrical equipment
such as transformers, switchgears,
machines, etc.

Features

Fluke 1625

1623
O
O
O

One-button measurement concept


3- and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-Pole resistance measurement AC
2-and 4-pole resistance measurement DC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Measuring frequency 128 Hz
Earth impedance measurement at 55 Hz
Automatic frequency control (AFC) (94 128 Hz)
Measuring voltage switchable 20/48V
Programmable limits, settings
Continuity with buzzer
Dust/water resistance
Safety rating

1625
O
O
O
O
O
O

O
O
O

IP56
CAT II 300 V

O
O
O
O
O
IP56
CAT II 300 V

Specications
(Check the Fluke web for detailed specications)
Fluke 1625 kit

Included accessories
Fluke 1623: Protective holster, 2 test leads,
2 alligator clips, users manual
Fluke 1623 Kit: same as above plus stake/reel
Set 4 pole and selective/stakeless clamp set
Fluke 1625: Protective holster, 2 test leads,
2 alligator clips, users manual
Fluke 1625 Kit: same as above plus stake/reel
set 4 pole and selective/stakeless clamp set

Fluke 1623 Kit


Fluke 1625

Recommended Accessories

www.chorus.ro
Fluke 1625 Kit

40

Basic GEO Earth Ground


Tester
Basic GEO Earth Ground
Tester Kit
Advanced GEO Earth
Ground Tester
Advanced GEO Earth
Ground Tester Kit

1625
0 to 300 k
5%
20 / 48 V
250 mA

Battery type: 6 x AA alkaline cells


Size (HxWxD): 110 mm x 180 mm x 240 mm
Weight 1623 Geo: 1.1 kg (including batteries)
1625 Geo: 1.1 kg (including batteries)
Two Year Warranty

Ordering information
Fluke 1623

1623
0 to 20 k
5%
48 V
> 50mA

Resistance ranges
Operating error
Test voltage
Short circuit current

EI-1623
EI-1625
Selective/stakeless clamp Selective/stakeless clamp
set for 1623
set for 1625

ES-162P3
Stake/reel set for 3 pole
measurements

ES-162P4
Stake/reel set for 4 pole
measurements

EI-162BN
320mm Split core
transformer for selective
measurements on high
voltage pylons

1621 Earth Ground Tester


Handheld earth ground testing
for mobile use
The Fluke 1621 is an easy-to-use
earth ground tester. The first line of
defense in detecting reliable ground
connections, the unit features basic
ground testing methods including 3-pole
Fall-of-Potential as well as 2-pole ground
resistance. Its convenient size, rugged
holster, and large, clear LCD display make
it an ideal field earth tester, for most
work environments. With a simple user
interface and intuitive functionality, the
Fluke 1621 is a handy tool for electrical
contractors, utility test engineers, and
earth ground specialists.

Features
3-pole Fall-of-Potential earth testing for
basic measurements
2-pole resistance measurements for
added versatility
Easily capture values with single-button
operation
Ensure accurate measurements with
automatic noise voltage detection
Hazardous voltage warning offers
increased user protection
Clearly read and record data with a
large, backlit display
Rugged holster and design for tough
work environments
Portable size allows for easy
transportation
Instantly be alerted to measurements
outside of your set limit, when you use
the adjustable limit setting
Safety rating CAT II 600 V

Fluke 1621

Specications
(Check the Fluke web for detailed specications)
1621
0.15 to 2 k
6% of measured value + 5D
18% of measured value +5D
23 to 24 V AC
> 50 mA AC

Resistance range
Basic accuracy
Operating error according EN61557
Test voltage
Short circuit current

Battery type: 1 x 9 V alkaline (LR61)


Size (HxWxD): 216 mm x 113 mm x 54 mm
Weight: 0.850 kg
Two Year Warranty

Recommended Accessories
Included accessories
Two measuring leads with alligator clips 2 m, protective holster, users manual, CD-ROM

www.chorus.ro
Ordering information
Fluke 1621

Earth Ground Tester

GEO CABLE-REEL 25M


Ground Earth Cable Reel
25 M Wire

GEO CABLE-REEL 50M


Ground Earth Cable Reel
50 M Wire

GEO EARTH STAKE


Ground Earth Stake

ES-162P3
Stake/reel set for 3 pole
measurements

41

1630 Earth Ground


Clamp Meter
Fast and easy earth ground loop testing
The Fluke 1630 earth ground clamp
meter simplifies ground loop testing and
enables non-intrusive leakage current
measurement. The ground loop testing is
also known as stakeless earth ground
testing. To carry out the measurement
there is no need for placing earth stakes
and disconnecting the earth system
from the electrical installation. The Fluke
1630 combines the two current clamps
needed to perform the stakeless ground
loop test in one compact and easy to use
instrument.
Ground loop resistance testing without
any disconnection or additional earth
stakes
Earth ground leakage current
measurement for system
troubleshooting
True RMS AC current measurement
range up to 30 A

Rapid evaluation of continuity without


disconnection and audible HI/LO alarm
Display-HOLD function to freeze
measurements
Recording function for automatic
storage of measured values, which can
be recalled later on the LCD display
Automatic self calibration ensures
correct measurement every time
The Fluke 1630 is ideally suited for the
following applications:
Ground loop checks on any earthing
system
Continuity tests on earth bonding
circuits and connections
Inspection of lightning protection
systems
Leakage current measurement for
troubleshooting on earth ground
systems

Specications
(Check the Fluke web for detailed specications)

Fluke 1630

Range
0.025 to 1500
< app. 40
0.2 to 1000 mA
0.2 to 30 A

Resistance
Cntinuity buzzer
Leakage current
Current

Max. resolution
0.002
0.001 mA
0.01 A

Weight: 0.64 kg
Conductor Size: 35 mm approx.
Size (HxWxD): 257 mm x 100 mm x 47 mm
Battery type: 9 V IEC 6 LR 61
Two Year Warranty

Ground resistance measurements principle


Ground resistance measurements principle

1630
EARTH
D

GROUN

CLAMP

OFF

CAT
300

HOLD

mA

FUNC
REC

Rg

R1

R2

R3

.....Rn

Equivalent circuit diagram

Included Accessories
163
0
TH
EAR
GRO
UND

R1

CLAM

R2

OFF

CAT
300

HOL

mA

FUNC

Rugged carrying case with belt, Resistance test


loop, 9 V battery, Operating instructions.

REC

Ordering Information
Fluke 1630

163
TH
EAR
GRO
UND
CLAM
P

D
HOL

OFF

CAT
300
V

FUNC
REC

www.chorus.ro

Rg

mA

42

Earth Ground Clamp Meter

Rg

.....Rn

Installation Testers/
Portable Appliance Testers
Our multifunction testers have redefined the standards for ease-of-use.
With new features like the fast, high current loop test, RCD Type B
compatibility, extended memory, and the fact they are designed for
ensuring fixed wiring installed according to IEC 60364,they perform all
tests required to verify safety. Our Portable Appliance Testers verify the
safety and operation of portable appliances, and are designed for onetouch operation and a fast throughput.

www.chorus.ro

43

1650 Series Multifunction


Installation Testers
New
RCD Type B Compatibility

Fluke 1654B

Extra functionality, faster testing,


and as rugged as ever
Safer, easier installation testing. The
new 1650 Series builds on the rugged
reputation of the earlier 1650 Series,
only its re-designed to meet your need
for more productive test tools. With
new features like the fast, high current
loop test (including a non-trip test)
and a variable RCD trip current setting,
accuracy is even better and the test
cycle even faster. And with the addition
of a unique zero adapter accessory for
accurate mains test lead compensation,
the 1650 Series continues to set the
standard in installation testers. The
1650 Series testers verify the safety
of electrical installations in domestic,
commercial and industrial applications.
They can ensure that fixed wiring is
safe and correctly installed to meet the
requirements of IEC 60364, HD 384 and
BS 7671 17th Edition wiring regulations.

Fluke 1653B

1654B - The complete tester for


advanced users
This is the instrument that has it all, in
a word: its complete. From all the test
functions you need to in-built memory

for documenting results. This makes it


the complete solution for professionals,
especially contractors, everyone who
would want to have the best tool
available and always understands (or
know) how to use.
1653B - The ideal tester for
professional trouble-shooters
This is the instrument that is indeed
ideal for professional users due to its
additional functionality. It is also ideal
since even though it has high-end
features, it is still easy to use even
after longer periods of non-use; because
operating it is intuitive and not forgotten
easily.
1652C - The everyday tester, for
every electrical installer
This is the instrument that can be
used every single day (day in, day out),
and covers all the basic needs. It is the
preferred tester for every front-line
electrician/installer.

Features
1652C

1653B

1654B

Insulation Resistance

Continuity & Resistance

Loop & Line Resistance

Measurement Function
Voltage & Frequency

Fluke 1652C

Prospective Earth Fault Current (PEFC/IK)


Prospective Short-Circuit current (PSC/IK)

RCD switching time

RCD tripping level

ramp test
O

ramp test
O

ramp test
O

RCD variable current

Automatic RCD test sequence

Test pulse current sensitive RCDs (Type A)

O
O

Test smooth dc sensitive RCDs (Type B)


O

Self-test

Illuminated Display

Earth Resistance
Phase Sequence Indicator

BS7671 17th Edition IEE Wiring


Regulations IEC 60364.6.61, HD 384

O
O

Loop & Line Resistancem1 resolution

Other Features

Memory, Interface

Included Accessories
6 AA Cell batteries
C1600 Hard carrying case
Zero Adapter
Mains test cord
TL165X STD Standard Test Lead Set
TL165/UK Fused Test Lead Set (UK only)
Padded carrying strap
Quick reference guide
TP165X Remote control probe and lead
Users manual on CD-ROM

Memory

O
O

Extended Memory
Computer Interface

Time and date (When used with FlukeView software)

Software

Included Accessories
Hard case

Remote control probe

Zero Adapter

Recommended Accessories
See also page 48 for more details

Ordering Information
Fluke 1652C Multifunction Installation Tester
Fluke 1653B Multifunction Installation Tester
Fluke 1654B Multifunction Installation Tester

44

www.chorus.ro
Check the Fluke website for the various
software modules

TLK290

MTC1363 (UK)

MTC77 (Europe)

ES165X 1653B &1654B

FVF-SC2

1650 Series Multifunction


Installation Testers
Extra functionality, faster testing,
and as rugged as ever
Specications
(Check the Fluke web for detailed specications)
AC Voltage Measurement
Range

Resolution

Overload Protection

0.1 V

Accuracy
50 Hz - 60 Hz
(0.8% + 3 digits)

Input Impedance

500 V

3.3 M1

660 Vrms

Resolution

Test Current

Open Circuit Voltage

Accuracy

00.1 1
0.1 1
11

> 200 mA

>4V

(1.5%+3 digits)

Continuity Testing
Ratnge
(autoranging)
20 1
200 1
2000 1

Insulation Resistance Measurement

Slim probe design


Thanks to its slim probe with integral test button,
you can safely make one-handed measurements
on hard to reach points, while keeping your eyes
on the panel. This remote probe is powered by
the tester so always operable (does not require
additional batteries!).

Model

Test Voltage

1653B / 1654B
1653B / 1654B

50 V
100 V

Insulation
Resistance Range
10 k1 to 50 M1
20 k1 to 100 M1

1653B / 1654B
1653B / 1654B
1653B / 1654B
1652C
1653B / 1654B
1653B / 1654B
1652C

250 V

20 k1 to 200 M1

500 V

20 M1
200 M1
500 M1
20 M1
200 M1
1000 M1

1000 V

Resolution

Test Current

Accuracy

0.01 M1
0.01 M1
0.1 M1
0.01 M1
0.1 M1
0.01 M1
0.1 M1
1 M1
0.1 M1
1 M1

1 mA @ 50 k1
1 mA @ 100 k1

(3%+ 3 digits)
(3%+ 3 digits)

1 mA @ 250 k1

(1.5%+ 3 digits)

1 mA @ 500 k1

(1.5%+ 3 digits)
+ 10%

1 mA @ 1 M1

(1.5%+ 3 digits)
+ 10%

Loop Impedance Measurement


Range
10 1

Resolution
0.001 1

20 1

0.01 1

200 1

0.1 1

2000 1

11

Accuracy [1]
Hi Current m1 mode: (2 % + 15 digits)
No Trip mode: ( 3 % + 6 digits)
Hi Current mode: (2 % + 4 digits)
No Trip mode: (3 %)
Hi Current mode: (2 %)
6 % [2]

Notes
[1] Valid for resistance of neutral circuit <20 1 and up to a system phase angle of 30. Test leads must be zeroed before testing.
[2] Valid for mains voltage >200 V.

PFC. PSC Test


Range
Resolution and Units
Accuracy

1000A / 10kA(50kA)
1A / 0.1kA
Determined by accuracy of loop resistance and mains
voltage measurements

Computation
Prospective Earth Fault Current (PEFC) or Prospective Short Circuit Current (PSC) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

Zero Adaptersign
For easy, always reliable and accurate
compensation for test leads and mains cords.
This adapter can be used for all different kind
of mains plugs as well as test accessories like
probes, alligator clips etc.

RCD Testing
AC [1]
AC
A [4]
A
B [5]
B

RCD Type [6]


G [2]
S [3]
G
S
G
S

Notes
[1] AC - Responds to ac
[2] G - General, no delay
[3] S - Time delay
[4] A - Responds to pulsed signal

Model 1652C

Model 1653B

Model 1654B

[5] B - Responds to smooth dc


[6] RCD test inhibited for V >265 ac
RCD tests permitted only if the selected current,
multiplied by earthing resistance, is <50 V.

Tripping Time Test (6T)


Current Settings
10, 30, 100, 300, 500, 1000 mA, VAR
10, 30, 100 mA

Multiplier
x 1/2
X5

Test Current Accuracy


+ 0% - 10%
+ 10% - 0%

Trip Time Accuracy


(1% Reading + 1 digit)
(1% Reading + 1 digit)

Tripping Current (Ramp) Test


Current Range

Dwell Time

Step Size
Type G

30 % to 110 % of
RCD rated current [1]

10 % of I 6 N

[2]

Notes
[1] 30 % to 150 % for Type A 6 N >10 mA
30 % to 210 % for Type A 6 N =10 mA
20 % to 210 % for Type B
Specified trip current ranges (EN 61008-1):

300 ms/step
50 % to 100 %
35 % to 140 %
35 % to 200 %
50 % to 200 %
[2] 5% for Type B

for
for
for
for

Type
Type
Type
Type

Type S

Measurement
Accuracy

0 ms/step

5 %

AC
A ( >10 mA)
A ( )10 mA)
B

Earth Resistance Test (RE) Fluke 1654B and 1653B only


Range
200 1
2000 1

Complete kit
All 1650 models are equipped with detachable
leads that can be replaced in case of damage
or loss. A durable hard case will protect your
instrument in tough field conditions.

Battery type: Alkaline supplied. usable


with 1.2 V NiCD or NiMH rechargeable
batteries
Size (HxWxD): 100 mm x 250 mm x 125 mm

www.chorus.ro

Resolution
0.1 1
11

Accuracy
(2% + 5 digits)
(3.5% + 10 digits)

Weight: 1.3 kg
Three Year Warranty

45

6000 Series PAT Testers


Versatile PAT testing at your fingertips
The Fluke 6200 and 6500 PAT testers
verify the electrical safety and operation
of portable appliances in accordance
with relevant guidelines and regulations.
With powerful auto test capabilities and
simplified controls they increase the
number of tests you can perform per day
without compromizing results.

Fluke 6200

Fluke 6500

A choice of automatic and manual


PAT testers
Both models perform all the tests
required for class I and class II
appliances. For manual testing and low
volume applications, choose the costeffective 6200 PAT model. If you need a
more powerful instrument to test large
numbers of appliances, the 6500 is the
right choice.

Fluke simplifies portable


appliance testing
Compact and lightweight
Efficient to work with and easy to carry
around and has extra space in the
hard case for accessories.
One touch simplicity
Pre-set and user-definable test routines
are initiated from a single button to
speed up test procedures and save you
time on site.
A better way of working
Rapid data entry via a QWERTY
keyboard (or optional Fluke barcode
scanner) and fast data transfer from
the main memory or the Compact Flash
memory card (6500).

6200

6500

Dedicated key for each test for onetouch testing


Pre-set pass/fail levels to save time
Large backlit display for easy reading

As 6200 but also with:


Integral QWERTY keyboard for rapid
data entry
Slot for Compact Flash memory card for
back-up data storage and transfer to PC
Pre-set, auto-test sequences for user
convenience

Also available with European mains socket.

Features

Included Accessories
Test lead, Test probe, Crocodile clip,
Mains cord

Ordering Information
Fluke 6200
Fluke 6500

PAT Tester
PAT Tester

Not available in all countries

Measurement functions
L N Mains Volts
Outside Limits Indicators
Null out facility for earth bond lead
Protective Earth Resistance PE (200mA)
Protective Earth Resistance PE (25A)
Insulation 500V dc
Protective Earth Conductor Current
Touch Current
Substitute Leakage Current
Appliance Power kVA
Appliance Load Current
Seven Segment Custom LCD
Graphical LCD
Back Light
Compact Flash Card receptacle
Serial Port - Printing / Downloading

O
O

6500
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

External printer output


Front Panel QWERTY Key pad

O
O

IEC Lead Test


Auto-testing
Pass / Fail Level Programmable Indicators
Data Storage
Limited Data Storage
Polarity Checks
Graphical Help Menu On Line
Programme Mode
Real time clock

O
O
O
O

www.chorus.ro

Front panel results management


230V BS1363 Test socket / 230V Mains BS1363 input power plug

46

6200
O
O
O
O
O
O
O
O
O
O
O
O

O
O

O
O
O
O
O
O

6000 Series PAT Testers

Specications
The accuracy specification for the display range is defined as (%reading + digit counts) at 23 C 5 C, 75 %
RH. Between 0 C and 18 C and between 28 C and 40 C, accuracy specifications may degrade by 0.1 x (accuracy
specification) per C. The measurement range meets the service operating errors specified in EN61557-1: 1997,
EN61557-2: 1997 , EN61557-4: 1997.

Separate hard case


The compact Fluke PAT testers are supplied with a
hard carrying case that not only offers protection
during transit but also includes extra storage space for
accessories and other tools. Theyre extremely light,
weighing approximately 3 kg (without case) and have
integral carrying handles for extra convenience.

Power-on Test

Touch Current Test

The test indicates reversed L-N, missing PE, and


measures the mains voltage and frequency.
Display Range
90 V to 264 V

Display Range

0 to 1.99 mA ac

Accuracy

(4% + 2 counts)

Resolution

0.01 mA

Accuracy at 50 Hz

(2% + 3 counts)

Resolution

0.1V (1V - model 6200)

Input Impedance

> 1 M // 2.2 F

Maximum Input Mains Voltage

300 V

Internal Resistance (via probe)

2 k

Measuring method

Probe

The appliance under test is energized at mains potential.


Substitute Leakage Current Test
Display Range

0 to 19.99 mA ac

Display Range

0 to 19.99

Accuracy

(5% + 5 counts)

Accuracy
(after Bond Test zeroing)
Resolution

(5% +4 counts)

Resolution

0.01 mA

Test Voltage

35 V AC 20%

Test Current

Operational Error

10%

Open Circuit Voltage

200 mA AC - 0% + 40% into


1.99
25 A AC 20% into 25 m
at 230 V
> 4 V AC, < 24 Vac

Bond Test zeroing

can subtract up to 1.99

Earth Bond Test

0.01

Load/Leakage Test: Load Current


Display Range

0 to 13 A

Accuracy

(4% + 2 counts)

Resolution

0.1 A

The appliance under test is energized at mains potential


Insulation Test (Riso)

Special PAT Kit


If you need a complete PAT tester solution,
a purpose made kit is available.
Fluke 6500/UK Kit Contains:
6500, Mainframe
EXTL 100, Extension lead test adaptor
SP Scan 15, Barcode scanner
Fluke PowerPat Plus
Pass 560R, Appliance pass labels
Fail 100S, Appliance fail labels APP 1000,
Barcode appliance number labels

Load/Leakage Test: Load Power

Display Range

0 to 299 M

Accuracy

Auto discharge time

(5% + 2 counts) from 0.1


to 50 M
(10% + 2 counts) from 50
to 299 M
0.01 M (0 to 19.99 M)
0.1 M (20 to 199,9 M)
1 M (200 to 299 M)
500 V DC - 0% + 25% at
500 k load
> 1 mA at 500 k load,
< 15 mA at 0
< 0.5 s for 1 F

Max. Capacitive Load

Operational up to 1 F

Resolution

Test Voltage
Test Current

Display Range

0 to 999 VA
1.0 kVA to 3.2 kVA
(5% + 3 counts)

Accuracy
Resolution

1 VA (0 to 999 VA)
0.1 kVA (1.0 kVA to 3.2 kVA)
The appliance under test is energized at mains potential

Load/Leakage Test: Leakage Current


Display Range

0.25 to 19.99 mA

Accuracy

(4% + 4 counts)

Resolution

0.01 mA

The appliance under test is energized at mains potential

(Kit contents may vary per country)

PELV Test
Accuracy at 50 Hz

(2% + 3 counts)

Overload protection

300 Vrms

Warning threshold

25 Vrms

Display Screens
Size (HxWxD): 200 mm x 275 mm x 100 mm
Weight: 3 kg
Two Years Warranty

Substitute Leakage
Current Test

Earth Bond Test (RPE)

Recommended Accessories
See also page 48 for more details

www.chorus.ro
Insulation Test (RISO)

Touch Current Test

Fluke PowerPat Plus


software

SP1000-02
Mini printer

SP-SCAN-15
Barcode scanner
(6500 Fluke only)

BDST3 Snap Tags


Cable Tie

PASS
Appliance 560R
Pass Labels

47

1650 Series/6000 Series


Accessories
Accessories for Fluke 1650
Series Installation Testers

Accessories for Fluke 6500 Series


Portable Appliance Testers

PASS560R Appliance Pass Labels


ES165X Earth Spike Test Kit
(Fluke 1653B and 1654B)

Quantity 500

SP1000 Mini Printer


Without using any additional software the
SP1000 can be used to directly printout stored
test records on to thermal paper. The printer
is compact and easily transported and is ideal
for test professionals who need to issue an
immediate written account of work carried
out. The printer is powered by a rechargeable
battery and comes complete with mains
charger and RS232 Printer Lead.

Earth Spike Test kit contents:


Auxiliary earth probes
Test connection leads and crocodile clips
Purpose-made carry case

APP1000/APP2000 Bar Code Appliance


Number Labels
APP1000: Labels numbered 0001-1000
APP2000: Labels numbers 1001-2000
Label number >2000 on request

FVF-SC2 Fluke ViewForms Software


(Fluke 1653B)
To address the increasing demands for
reporting and documentation, Fluke presents
FlukeView Forms documenting software.
Download the data from the Fluke 1653B and
create an easy report. The Fluke ViewForms
Software also supports other Fluke tools.
See page 132.

Replacement thermal paper for the SP1000


Mini Printer

Fluke DMS software for


1650/6000 Series

BDST3/BDST4 Snap Tags


BDST3: Cable Tie
BDST4: Clip On
Quantity 20. Without labels.

TLK 290 Test Probe Kit


Kit includes three flexible socket probes and
a large alligator clip
To be used on three phase sockets
Probes have flexible width test points that fit
securely in 4 to 8 mm sockets
CAT III 1000 V, 8 A

SP1000 Paper

EXTL100-02 (UK plug)

EXTL100-02 (Schuko plug)

EXTL100 Extension Lead Test Adaptor


Adaptor for testing extension leads. Allows
the earth test lead to be connected to the
extension leads to perform insulation and
earth bond tests.

The Fluke DMS (Data Management Software)


is an efficient program for administration and
reporting of installation tests in compliance
with EN 60364, DIN VDE 0100/0105, BS7671
17th edition wiring resulation and appliance
tests in compliance with DIN VDE 0701/0702,
VE E 8701.

DMS 0100/INST Software for Installation


Tester Fluke 1653B and 1654B
Supporting reports for Austria, Germany, UK,
Switzerland, Netherlands

DMS 0702/PAT Software for Portable


Appliance Tester Fluke 6500
Supporting reports for Austria, Germany, UK,
Netherlands

DMS COMPL PROF Software for the Fluke


1654B, 1653B and Fluke 6500
Supporting reports for Austria, Germany, UK,
Switzerland, Netherlands
MTC1363

MTC77

Mains Test Cord for 1650B series


MTC1363
MTC77

48

UK plug
Schuko plug

SPScan15 Barcode Scanner


Easy to use, low current, intelligent barcode
reader. SPScan15 can be used to scan barcodes
attached to curved surfaces or where actual
contact with the barcode surface is difficult.

www.chorus.ro

Digital Thermometers
For troubleshooting systems where temperature is a critical symptom,
our digital thermometers provide you with laboratory accuracy wherever
you need it. We offer a choice of non-contact, laser-guided infrared
thermometers for safely getting at hard-to-reach, electrically live or
particularly hot targets, and contact thermometers with a full range of
thermocouple probes.

www.chorus.ro

49

50

Contact thermometers
For our complete range of contact
thermometers, see page 55.

www.chorus.ro

See catalog page

Adjustable emissivity
MIN/MAX readings
AVG readings
DIF readings
Backlit LCD
Bar graph display
Audible Hi/Lo alarm
Visible Hi/Lo alarm
Includes contact probe
Probe input (types)
Data logging
(number of
measurements)
PC interface
Compatible with
FlukeView Forms
software

Laser sighting

Close focus model


available
Recommended distance
to spot

Temperature range
Accuracy
Response time
Optical resolution

Infrared Thermometer
Selection Guide

52

-/O

single-point
laser

Up to 2 m

Fluke 60 Series
Fluke 62
-30 to 500 C
1.5%
< 500 mSec
10:1

Plant/facilities maintenance
Preventive and predictive maintenance
Energy audits
Vehicle and fleet maintenance
programs
Faulty electrical/circuit connections
Petrochemical/hazardous locations
Motors, pumps and bearings

52

single-point
laser

Up to 2 m

Fluke 61
-18 to 275 C
2%
< 500 mSec
8:1

54

O
Type K Thermocouple

O
O

single-point
laser
O
O

Up to 2.5 m

Fluke 561
- 40 to 550 C
1%
< 500 mSec
12:1

Heating/ventilation/air conditioning/
refrigeration
Leaky ductwork
Thermostats
Temperature balancing
Steam distribution systems
Compressor lines

52

-/O

single-poimt
laser

Up to 2.5 m

Fluke 63
- 32 to 535 C
1%
< 500 mSec
12:1

Manufacturing processes
Molding temperature measurement
Printing, paper and converting
Thermoforming plastics
Electronics
Paint curing/drying
Food
Chemical and pharmaceutical

Safety and protection


Fire localization
Hazardous materials
Faulty ballasts
Search and rescue
Smoldering embers
Equipment maintenance

Recommended Applications

51

51

O
53

RS232

USB

53

100 points

99 points

20 points

O
O
O/O/-

O
O
O
Type K Thermocouple

300 mm
(with close
focus) up to 10.5 m
3-point
laser
O
O
O
O
O
O
O
O
O
Type K Thermocouple

O
O
O
Type K Thermocouple

300 mm
(with close
focus) up to 10.5 m
3-point
laser
O
O

Fluke 570 Series


Fluke 572
Fluke 574
- 30 to 900 C
- 30 to 900 C
0.75%
0.75%
< 250 mSec
< 250 mSec
60:1 (50:1
60:1 (50:1
with close
with close
focus)
focus)
O
O

single-point
laser
O
O
O
O
O

Up to 7.5 m

Fluke 568
- 40 to 800 C
1%
< 500 mSec
50:1

single-point
laser
O
O
O
O
O

Up to 4.5 m

Fluke 560 Series


Fluke 566
- 40 to 650 C
1%
< 500 mSec
30:1

Infrared Thermometer
Selection Guide

570 Series
Precision Infrared Thermometers
Measure temperature with ease and
precision
The Fluke 570 series are the most
advanced IR non-contact thermometers,
and are ideal for predictive and
preventative maintenance applications.
Offering a broad temperature range
and a true dimension laser sighting
system for precise targeting resulting
in more accurate measurements. When
requiring analysis and documentation
use the 100-point data logging and
software for graphing and analysis.
From close-up electrical connections, to
far-distance room balancing checks, the
Fluke 570 series can take IR temperature
measurements with ease and precision.

Enhanced optics allows measurements


of smaller objects from farther away
True Dimension three-dot laser
sighting system highlights the true
diameter of measurement spots at all
distances
Adjustable emissivity setting and 30
pre-set common material values for
more accurate measurements
100 data point memory for storage of
measurements (Fluke 574).

Fluke 574

Features
572
Temperature range
Optical resolution

574
-30 to 900C
Standard: 60:1
Close focus: 50:1

3 dot laser beam for accurate targeting


Adjustable emissivity
Bar graph display
Backlit LCD display
Use selectable C or F
Audible and visible Hi/Lo Alarm
MIN/MAX
AVG/DIF readings
Datalogging (number of measurements)
PC interface

O
O
O
O
O
O/O

O
O
O
O
O
O/O
O
O
100
RS232

Specications
572

Fluke 572

Included Accessories
Fluke 572: Hard case, 2 batteries
Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software,
RS232 cable

Ordering Information

Temperature range
Response time
Resolution
Repeatability
Accuracy: (assumes ambient operating temperature of 23 C to 25 C )
Typical distance to target
Emissivity

574
-30 to 900C
250ms (95 % of reading)
0.1C of reading up to 900C
0.5% of reading or 1C*
0.75% of reading, 0.75C *
10,5 m
Digitally adjustable from 0.10 to 1.0
by 0.01

*whichever is greater.

Battery Life: 10 hours typical


Weight: 0.480 kg
Size (HxWxD): 200 mm x 170 mm x 55 mm
Two years warranty

Fluke 572
Precision Infrared Thermometer
Fluke 574
Precision Infrared Thermometer
Fluke 572CF Precision Infrared Thermometer
with close focus option
Fluke 574CF Precision Infrared Thermometer
with close focus option

www.chorus.ro

Recommended Accessories

AN5
Analog data cable

51

60 Series
Infrared Thermometers
Point, press and read temperature
The Fluke 60 Series non-contact
thermometers are the ideal professional
diagnostic tools for quick and accurate
temperature measurements.
These handheld tools are ideal for
measuring surface temperatures of
rotating, hard-to-reach, electricity live
or dangerously hot targets like electrical
motors and panels, and heating and
ventilation systems.
The laser sighting system guides
measurements to the right target and in
less than a second, the large temperature
display provides a readout of the surface
temperature.

Fluke 63

The 60 Series IR thermometers


feature:
Laser guided sighting system for easy
targeting with 1% accuracy
Up to 12:1 optical resolution
Backlit display for easy reading in the
dark
Temperatures up to 535C

Features

Fluke 62

Form factor

61

62

63

Flat grip

Pistol grip

Pistol grip

Temperature range

-18 to 275C

-30 to 500 C

-32 to 535C

Optical resolution

8:1

10:1

12:1

Laser beam for accurate targeting

O
O
O

O
O
O

O
O
O

Max

Max

Backlit LCD display


Use selectable C or F
Min/max/avg/dif readings

Specifications
Range
Response time
Resolution

Fluke 61

62

63

- 30 to 500 C

- 32 to 535 C

< 500ms

< 500ms
(95 % of reading)
0.2 C

0.5 second

0.5%
or < 1 C*
For targets at:
10 C to 30 C: 1 C
1.5% of reading
or 1.5C whichever
is greater over
the balance of the
range

0.5%
or 1 C*
For targets at:
-32 to -26C: 3C
-26 to -18C: 2.5C
-18 to 23C: 2C
23C -510C: 1%
of reading or 1C*
For targets
above 510C:
1.5% of reading

0.2 C

Repeatability
(% of reading)
Accuracy:

(assumes ambient operating temperature of 23C)

The Fluke FoodPro thermometer


series provide advanced
temperature measurement solutions
for the foodservice industry. Check
the Fluke web for more information.

61
- 18 to 275C

2%
or 2 C*
For targets at:
-18 to -1C: 3C
-1 to 275C: 2% of
reading or 2C

Typical distance to target


Emissivity

0.2 C

Up to 1m

Up to 1.5 m

Up to 2 m

Fixed at 0.95

Pre-set to 0.95

Fixed at 0.95

* whichever is greater

Included Accessories

Fluke 61: 9V Battery


Fluke 62: 9V Battery, storage holster
Fluke 63: Hard carrying case, 9V batteries

Ordering information

Fluke 61
Infrared Thermometer
Fluke 62
Mini Infrared Thermometer
Fluke 63
Infrared Thermometer
Fluke 62/322/1AC-E (see page 5)
Fluke T5-600/62/1AC (see page 5)
Fluke FP
FoodProTM Food Safety
Thermometer
Fluke FP Plus FoodProTM Plus
Food Safety Thermometer

52

Battery Life:
Fluke 63:
Fluke 62:
Fluke 61:

10 hours with laser and backlight on


12 hours with laser and backlight on
12 hours with laser and backlight on

Size (HxWxD):
Fluke 63:
Fluke 62:
Fluke 61:

200 mm x 160 mm x 55 mm
152 mm x 101 mm x 38 mm
184 mm x 45 mm x 38 mm

Kits

0.320 kg
0.200 kg
0.227 kg

Fluke 62: 2 years warranty


Other models: one year warranty

Recommended Accessories

www.chorus.ro
Fluke 62/322 kit

Weight:
Fluke 63:
Fluke 62:
Fluke 61:

T5-600/62/1AC-E

C23
See page 130

H6
See page 131

566 and 568


Multipurpose Thermometers
The two-in-one infrared and contact thermometer with an innovative graphical display
With a straight-forward, menu-driven
user interface and graphical display,
the Fluke 566 and 568 multipurpose
thermometers make even complex
temperature measurements easy. Quickly
navigate and adjust emissivity, start data
logging, or turn on and off alarms, with
just a few pushes of a button. For added
convenience, both rugged handheld
thermometers combine contact and
non-contact temperature measurement
capability, providing a total temperature
measurement solution for any service
and maintenance program.

Fluke 566

Easily access advanced features with


the soft-key buttons and graphical
display
Measure smaller targets from farther
away using the IR thermometer
Adjustable emissivity and built-in table
of common materials for higher IR
accuracy
Quickly identify problems with the MIN,
MAX, AVG, and DIF functions
2-color flashing alarm alerts you
visually when measurements exceed
limits
Includes Type K thermocouple bead
probe
Compatible with all standard miniconnector K-type thermocouples
Data logging with a date/time stamp
Soft rubber boot for increased
ruggedness
User interface available in 6 languages

Fluke 568

Choose your language

Select the measurement surface

See complete measurement details


in seconds

Specifications
(Check the Fluke web for detailed specifications)
Infrared temperature range
Infrared accuracy

The Fluke 566 and included accessories

Display resolution
Infrared spectral response
Infrared response time
Input temperature range
Input accuracy
D:S (Distance to measurement spot size)
Laser sighting
Minimum spot size
Emissivity adjustment
Data logging with Date/Time stamp
PC interface and cable
Hi/Low alarms
Min/Max/Avg/Dif
Display
Backlight
Trigger Lock
Switchable between Celsius and Fahrenheit

The Fluke 568 and included accessories

Included accessories

566
568
-40 C to 650 C
-40 C to 800 C
< 0 C : (1.0 C + 0.1/1 C);
> 0 C : 1 % or 1.0 C, whichever is greater
0.1 C
8 m to 14 m
< 500 msec
-270 C to 1372 C
-270 C to -40 C: (1 C + 0.2 /1 C)
-40 C to 1372 C: 1 % or 1 C, whichever is greater
30:1
50:1
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
19 mm
By built-in table of common materials or digitally adjustable
from 0.10 to 1.00 by 0.01
20 points
99 points
None
USB 2.0 with FlukeView
Forms software
Audible and two-color visual
Yes
Dot matrix 98 x 96 pixels with function menus
Two levels, normal and extra bright for darker environments
Yes
Yes

Power: 2 AA/LR6 Batteries (566); 2 AA/LR6


Batteries and USB for use with a PC (568)
Battery life: Used continuously; laser and
backlight on: 12 hours; laser and backlight off:
100 hours

FlukeView Forms software (568 only), USB


cable (568 only), K-type thermocouple bead
probe, 2 AA batteries, hard carrying case,
quick start guide, and users manual.

Weight: 0.965 kg (566); 1.026 kg (568)


Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm
Operating temperature: 0 C to 50 C
Storage temperature: -20 C to 60 C
Two years warranty

Recommended Accessories

Ordering information
Fluke 566
Fluke 568

Infrared thermometer
Infrared thermometer

www.chorus.ro
H6
See page 131

80PK-8
See page 128

80PK-9
See page 128

80PK-11
See page 128

80PK-25
See page 128

80PK-26
See page 128

53

561
Multipurpose Thermometer
Combined Infrared and Contact Thermometer

Fluke 561

The Fluke 561 combines the temperature


measurement functions that industrial,
electrical, and HVAC/R professionals
need, all in one tool. It measures both
IR and contact temperature, replacing
several other test tools. Its fast, efficient,
and easy to use, saving you valuable time
and effort. With the Fluke 561, you can
take contact and ambient temperatures
in the way thats best for you. Use the IR
thermometer to measure hot, moving,
electrically energized, and hard-toreach objects instantly. Check motors,
insulation, breakers, radiant heating,
pipes, corroded connections, and wires.
Plus, scan ducts, and other hard-to-reach
objects from the floorleave your ladder
in the truck. You can use the Fluke 561s
handy Velcro pipe probe or, plug in any
industry standard, K-type mini-connector
thermocouple probe you already own.

IR thermometer for quick


measurements up close or at a distance
Single-point laser sighting
Easy emissivity adjustment for
measuring pipes and ducts more
accurately
Includes a Velcro pipe probe for superheat and sub-cooling as well as other
surface contact measurements
Also compatible with all standard miniconnector K-type thermocouples
MIN, MAX and DIF temperature
readings
Lightweight (only 340 grams) and
portable
Includes measurement guide

Specifications

The Fluke 561 includes everything you need for


immediate inspections.

Temperature range
Display resolution
D:S (Distance to spot size)
Easy emissivity selector
Display accuracy (Assumes ambient operating
temperature of 23 to 25C)
Response time
Repeatability
Spectral focus
Laser sighting
Laser shutoff
Laser power
Relative humidity
Power
Display hold
Backlit display
Operating temperature
Storage temperature
MAX, MIN, DIF temperatures
Thermocouple type K mini-adapter input
Thermocouple type K Velcro pipe probe
Measurement guide

-40 to 550C
0.1 of reading
12:1
Adjustable with three settings: low (0.3), medium (0.7), high (0.95)
1.0% of reading or 1C, whichever is greater; below 0C, 1C, 1/1
500 mSec (95% or reading)
0.5% of reading or 1C, whichever is greater
8 m to 14 m
Single-point laser
Laser turns off above ambient temperature of 40C
Class 2 (II) operation; output 1 mW, wavelength 630 nm to 670 nm
10% to 90% RH non-condensing, at < 30C
2 AA batteries (alkaline or NiCD)
7 seconds
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery,
F/C indicator, and Scan/Hold options
0 to 50C
-20 to 65C
Yes
Yes, compatible with industry standard type K probes with mini-connector
Yes, with a temperature range of 0 to 100C and accuracy of 2.2C
Yes

Battery Life (alkaline): 12 hours


Weight: 340 grams
Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm Two years warranty

Included accessories
Thermocouple K-type Velcro pipe probe,
hand carrying case, 2 AA batteries and user
manual with measurement guide.

Recommended Accessories

Ordering information
Fluke 561

54

HVACPro Thermometer

www.chorus.ro

H6
Se page 131

80-PK-1
See page 128

80PK-8
See page 128

80PK-25
See page 128

50 Series II Thermometers
Laboratory accuracy. Wherever you go.
Additional features for the 53 and
54 Series II:

The Fluke 50 Series II contact


thermometers offer fast response and
laboratory accuracy (0.05% + 0.3C) in
a rugged handheld test tool.
Large backlit dual display shows any
combination of T1, T2 (52 and 54 only),
T1-T2 (52 and 54 only) plus MIN, MAX,
or AVG
Relative time clock on MIN, MAX, and
AVG provides a time reference for major
events
Electronic Offset function allows
compensation of thermocouple errors
to maximize overall accuracy
Readout in C, F, or Kelvin (K)
Sleep mode increases battery life
Battery door allows easy battery
replacement without breaking the
calibration seal

Data Logging up to 500 points of data


with user adjustable recording interval
Real time clock captures the exact time
of day when events occur
Recall function allows logged data to be
easily reviewed on the meter display
IR communication port allows data to
be exported to optional FlukeView
PC software

Features
Thermocouple types
Number of inputs
Time stamp
Splash/Dust resistant
Dual display with backlight
Min/Max/Avg recording
(T1-T2) True differential
Data logging up to 500 points
IR data port for interface
to PC
Compatible with optional
FlukeView Software

Fluke 54 II B

51 II
J,K,T,E
Single
Relative Time
O
O
O

52 II
J,K,T,E
Dual
Relative Time
O
O
O
O

53 II B
J,K,T,E,N,R,S
Single
Time of Day
O
O
O
O
O

54 II B
J,K,T,E,N,R,S
Dual
Time of Day
O
O
O
O
O
O

Specifications
Fluke 51 II

Fluke 52 II

Fluke 53 II B

Included Accessories
Impact absorbing holster
Two bead probe thermocouples 80PK-1 (54+52)
One bead probe thermocouple 80PK-1 (51+53)

Ordering Information
Fluke 51 II
Fluke 52 II
Fluke 53 II B
Fluke 54 II B
FVF-SC2

Thermometer
Thermometer
Thermometer
Thermometer
FlukeView Forms Software
including USB interface cable

Temperature range:
J-type Thermocouples
K-type Thermocouples
T-type Thermocouples
E-type Thermocouples
N-type** Thermocouples
R** and S-type** Thermocouples
Temperature accuracy
Above 100C (-148F):
J, K, T, E, and N-type**
R** and S-type**
Below 100C (-148F):
J, K, E, and N-types
T-type

-210C to 1200C
-200C to 1372C
-250C to 400C
-150C to 1000C
-200C to 1300C
0C to 1767C

[ 0.05% + 0.3C ]
[ 0.05% + 0.4C ]
[ 0.20% + 0.3C ]
[ 0.50% + 0.3C ]

**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type

Battery life: 1000 hours typical, AA


Size (HxWxD): 173 x 86 x 38 mm

Weight: 0.4 kg
Three Year Warranty

Recommended Accessories

www.chorus.ro
C25
See page 130

80PK-26
See page 128

80PK-25
See page 128

FVF-SC 2
See page 132

TPAK
See page 132

55

1523 and 1524


Reference Thermometers
A new standard in
accuracy and versatility.
Measure, graph and record three
sensor types with one tool. The Fluke
1523/24 Reference Thermometer deliver
high accuracy, wide measurement
range, logging, and trending, all in a
handheld tool you can take anywhere.
For top accuracy, a memory chip inside
the probe connector feeds probe
calibration information to the readout.
In addition, any thermocouple with
a mini-thermocouple connector can
be read using the optional universal
thermocouple adapter. Choose the 1523
for single channel or the 1524 for dual
channel measurement.

Three sensor types

Fluke 1524

Fluke 1523

PRTs: 200 C to 1000 C


Thermocouples 200 C to 2315 C
Precision thermistors: 50 C to 150 C

High accuracy
PRTs: 0.011 C
Thermocouples: 0.24 C for J,K,L,M
Precision thermistors: 0.002 C

Fast measurement
PRTs: up to 0.45 seconds/sample
Thermocouples: up to 0.3 seconds/
sample
Precision thermistors: up to 0.3
seconds/sample

Two models
1523: Single channel standard model;
memory for 25 readings & statistics
1524: Two channels; memory for 25
readings and statistics plus logging
15,000 measurements; real-time clock
for time and date stamps

Features
Note: The 1523/24 are pictured with probes connected which may
be purchased seperately.

Included Accessories
NIST traceable certificate of calibration, users
guide, CD-ROM (contains technical manual),
12 V dc universal power supply, RS-232 cable,
9940 I/O ToolKit software

Sensor Types
Thermocouple Types
Number of inputs
Data trending (graphing)
Graphical display with backlight
Min/Max/Avg/Standard deviation recording
High speed measurement
RS-232 PC communications
T1-T2 True differential
Data logging up to 15,000 points
Time and date stamp

1523
1524
PRT & RTD, Thermistor, and Thermocouple
B,C,E,J,K,L,M,N,R,S,T,U
Single
Dual
O
O
O
O
O
O
O
O
O
O
O
O
O

Ordering Information
Fluke 1523*
Reference Thermometer
Fluke 1524*
Reference Thermometer
Fluke 1523-P1 Reference Thermometer,
PRT(200 C to 420 C, 6.35
mm x 298 mm), Universal
Thermocouple Adapter, TPAK,
and Case
Fluke 1524-P1 Reference Thermometer,
PRT(200 C to 420 C, 6.35
mm x 298 mm), Universal
Thermocouple Adapter, TPAK,
and Case
* Requires an optional probe

Specications
(Check the Fluke web for detailed specications)
Temperature range
Thermocouple
PRT & RTD
Thermistor
Resolution and best accuracy
Thermocouple
PRT & RTD
Thermistor
Operating temperature
Storage temperature

200 C to 2315 C
200 C to 1000 C
50 C to 150 C
0.01 , 0.24 C
0.001 , 0.011 C
0.001 , 0.002 C
10 C to 60 C
20 C to 70 C

Optional Accessories
2384-P
2384-T
2373-LPRT

INFO-CON Connector, PRT


(Gray Cap), Spare
INFO-CON Connector,
Thermocouple (Blue Cap),
Spare
RTD Adapter, Lemo to
Mini Grabbers (4-wire)

Battery life (alkaline): 20 hours


Power supply: Universal 12 Vdc
Size (HxWxD): 200 x 96 x 47 mm
Weight: 0.65 kg
Warranty: 1 year

Recommended Accessories

Optional probes:
5616-12-P
5615-9-P

www.chorus.ro
5610-9-P

56

PRT, 6.35 mm x 298 mm,


200 C to 420 C
PRT, 4.76 mm x 229 mm,
200 C to 420 C
Thermistor, 3.2 mm x 229 mm,
0 C to 100 C

TPAK

FLK80P1
(80PK1 with universal
thermocouple adapter)

FLK80P3
(80PK-3A with universal
thermocouple adapter)

2384P and 2384T


Spare INFO-CON Adapters

2373-LTC
Universal TC adapter

1551A Ex / 1552A Ex Intrinsically


Safe Stik Thermometers
New

The new gold standard of industrial


temperature calibration

1552A Ex

1551A Ex

Finally, a digital substitute for your


mercury-in-glass thermometers! Highly
accurate and durable, the Fluke 1551A
Ex/1552A Ex Stik Thermometer is soon
to become the new gold standard of
industrial temperature calibration.
Whether working outdoors in
environments where potentially
explosive gases may be present or on
the floor of a processing plant, the
intrinsically safe, battery-operated,
portable reference thermometer is
designed to go where you work.

temperature range. The large backlit


LCD display rotates 90 making it easy
to read from any position. Minimize
measurement errors with the userconfigurable temperature trend/stability
indicator which tells you when your
temperature source is stable or if your
temperature is trending up or down.
0.05 C accuracy over full range
Intrinsically safe (ATEX compliant)
Display temperature in C or F
Optional data logging to internal
memory
Temperature trend indicator
User selectable resolution (0.1, 0.01,
0.001)
300 hour battery life
Percent battery-life and low battery
indicator
NVLAP accredited calibration
(NIST traceable)

The RTD sensor of the Stik Thermometer


is housed in a rugged stainless steel
sheathyou no longer have to worry
about breaking a mercury-in-glass
thermometer and the subsequent
cleanup. The probe and digital readout
are fixed together, calibrated as a system,
and accurate to 0.05 C over the full

Specications
Temperature range
Accuracy (1 year)
Display units
Sensor type
Probe temperature coefficient
Sensor length
Sensor position (from sheath tip)
Minimum immersion depth1
Probe sheath material
Response time

Included Accessories
NVLAP accredited report of calibration, users
guide on CD-ROM, 3 AAA batteries

Ordering Information
1551A-9
1551A-12
1551A-20
1551A-9-DL

Stik Thermometer
Stik Thermometer
Stik Thermometer
Stik Thermometer with
datalogging
1551A-12-DL Stik Thermometer with
datalogging
1551A-20-DL Stik Thermometer with
datalogging
1552A-12
Stik Thermometer
1552A-12-DL Stik Thermometer with
datalogging

Probe hysteresis
Temperature resolution
Sample rate
Operating temperature range of readout
Storage temperature
Optional data logging2
Logging intervals2
Averaging
Communications
EMC compliance
Enclosure rating
Calibration
Characterization
1
2

1551A Ex
50 C to 160 C

1552A Ex
80 C to 300 C
0.05 C
C, F

100 thin film RTD


100 wire-wound PRT
0.00385 //C nominal
10 mm
30 mm
3 mm
70 mm
120 mm
SST
4.8 mm diameter probe (3/16 in): 14 seconds
6.35 mm diameter probe (1/4 in): 21 seconds
0.01 C
Selectable: 0.1, 0.01, 0.001 (default 0.01)
Selectable: 0.5, 1, 2, seconds (default 1)
10 to 50 C
20 C to 60 C , 0 to 95% RH, non-condensing
Up to 10k time-stamped readings stored to internal memory
2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
Moving average of most recent 2 to 10 readings, user selectable
(ON/OFF, 2,5,10)
RS-232 stereo jack (access calibration parameters only)
EN61326:2006 Annex C; CISPR II, Edition 5.0-2009; Class B
IP50
NVLAP accredited, NIST Traceable System Calibration
CVD
ITS-90

Per ASTM E 644


See ordering information for optional data logging configurations

Battery Life: 300 hours typical without LCD, 3 AAA


Size (HxWxD): 114 x 57 x 25 mm
Weight: 196 grams
Warranty: 1 year

Recommended Accessories
Note: Model number appended with a -9, -12, -20
indicates probe sheath length in inches. All probe
diameters are 6.35 mm with the exception of the
1551A-9, which is 4.8 mm diameter

www.chorus.ro

1551-CASE
Carrying case

1551-CBL
RS-232 cable

57

Thermal Imagers
Temperature changes can indicate problems in many everyday
applications and a thermal imager makes it quick and easy to visually
check surface temperatures. Often problems can be discovered before
contact measurements even need to be made. Fluke offers a complete
range of handheld thermal imagers for both industrial and building
diagnostic applications. Models are available for any budget.

58

www.chorus.ro

Ti Series Thermal Imagers


Find it, x it, fast!
Temperature changes can indicate problems
in many areas you see everyday, some
include:
Inside electrical distribution and service
(Switch gear, panels, controls,
fuses,transformers, receptacles, lighting,
conductors, bus bars, motor control
centers)
Motors, pumps and mechanical (Electric
motors and generators, pumps,
compressors, evaporators, bearings,
couplings, gearboxes, gaskets/seals, belts,
rollers, disconnects)
Process (Tanks and vessels, pipes, valves
and traps, reactors, process insulation)
HVAC/R (air conditioning, heating, air
handlers, refrigeration)
Outside electrical distribution - utilities
(Transformers, bushings, insulators,
transmission lines, other exterior
conductors, service connections,
disconnects, capacitor banks)

Overheating bearing cap

IR-Fusion Technology: Infrared and


visual images fused together in one image
See things both ways - Infrared and
visual (visible light) images fused
together communicating critical
information faster and easier
traditional infrared images are no longer
enough. Patented IR-Fusion Technology,
only available from Fluke, simultaneously
captures a digital photo and the infrared
image and fuses them together taking
the mystery out of IR image analysis.

Full IR

Picture-in-Picture

IR/Visible Alarm

Full Visible Light

Alpha Blending

Three-phase switch-gear
load imbalance

SmartView Software

Overheated motor

Cool corner in a building

Fluke SmartView software is included with each Fluke


Thermal Imager. This powerful software is a modular
suite of tools that annotates, views, edits and analyzes
IR images.
It also generates fully customizable and professionallooking reports in a few easy steps. The IR-Fusion
technology is fully supported.

FREE webinars/webcasts on
Thermal Imaging
Keep up-to-date on the latest troubleshooting
techniques. Attend a FREE Fluke webinar (web-based
seminar) about thermal imaging applications.
Go to the Fluke website for more information.

www.chorus.ro

59

Ti32/Ti29/Ti27 Industrial/
Commercial Thermal Imagers
The New P3 Series from Fluke
Designed for industrial and commercial environments, the Fluke P3 Series of
thermal imagers deliver superior image quality, versatility, and affordability without
compromise. They also boast superior infrared resolution, industry leading spatial
resolution, and a high definition display creating the sharpest images in their price
classes. Finding a potential problem before it becomes a costly disaster shows you
just how much a Fluke thermal imager can save you in time, money and even lifes.

Superior image quality


Fluke Ti32

New

Delivers the clear, crisp images needed to find problems fast with up to 320 x 240
sensor.
Identify even the smallest temperature differences that could indicate problems
with industry-leading thermal sensitivity (NETD), down to 45 mK.
Automatic alignment (parallax correction) of visual and infrared images with Fluke
patented IR-Fusion.
Optional telephoto and wide angle lenses available for added versatility and special
applications (easily installable in the field).

Easy to use

Fluke Ti29

Field replaceable batteries give you maximum flexibility no matter where your work
takes you.
Intuitive, three-button menu is easy to usesimply navigate with the push of a
thumb.
No need to carry pen and paperrecord findings by speaking into the imager. Voice
annotations can be recorded with every image you take. Voice comments are saved
along with individual images for future reference.
One-handed focus capability, emissivity correction, reflected background
temperature compensation, and transmission correction increase the accuracy of
measurements in most situations.
Adjustable hand strap for left-or right-handed use.
Everything needed to get started is included.

New

Rugged
Optimized for field use in challenging work environments.
Engineered and tested to withstand a 2 m drop for the ultimate peace of mind.
Withstands dust and watertested to an IP54 rating.
With their rugged design, integrated lens cover, protected display and 2 meter drop
test, they are designed to handle the harshest environments.

www.chorus.ro
Fluke Ti27

60

Ti32/Ti29/Ti27 Industrial/
Commercial Thermal Imagers
Specifications

Thermal imaging performance


Detector type

Fluke Ti27

Fluke Ti29

Fluke Ti32

240 x 180 Focal Plane Array,


uncooled microbolometer

280 x 210 Focal Plane Array,


uncooled microbolometer

320 x 240 Focal Plane Array,


uncooled microbolometer

Field of view (FOV)


Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (auto/manual)
Focus
Optional telephot infrared lens type
Field of view (FOV)
Minimum focus distance
Optional wide-angle infrared lens type
Field of view (FOV)
Minimum focus distance
Visual imaging performance
Minimum focus distance
On camera operating modes
Color Alarm
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes
Ultra Contrast Palettes
Voice Annotation
Voice annotation
Image and data storage
Storage medium

23 horizontal x 17 vertical
1.49 mRad
15 cm
0.05 C at 30 C (50 mK)
2.5 C / 5 C
Manual

1.67 mRad

1.25 mRad
0.045 C at 30 C (45 mK)

11.5 x 8.7
45 cm
46 x 34
7.5 cm
46 cm
Picture-in-Picture and full screen IR plus Blending
High temperature alarm
2.0 MegaPixel
-20 C to 600 C
2 C or 2%
Center point and hot and cold markers
9.1 cm (3.7) landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
O

2GB SD Card (3000 .bmp IR images/1200 .IS2 images)

File formats supported


Controls and adjustments
Set-up controls

JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, C/F, language
On screen emissivity correction
On-screen reflected background temperature compensation
On-screen transmission correction

Language selection

Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur

Image controls
Power
Battery type
Battery operating time

Smooth auto scaling and manual scaling


Two replaceable rechargeable battery packs (Lithium ion)
4+ hours per battery pack

Water and dust resistant: IP54


Size (HxWxD): 277 x 122 x 170 mm
Weight: 1.05 kg
Two Years Warranty

Complete package

Included Accessories
SmartView software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery (extra)
AC charger/power supply
User manual

FLK-LENS/TELE1
Telephoto Infrared Lens

FLK/LENS/WIDE
Wide-angle Infrared Lens

Recommended Accessories

Ordering Information

www.chorus.ro
Fluke Ti27
Fluke Ti29
Fluke Ti32

Thermal Imager
Thermal Imager
Thermal Imager

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery

FLK-TI-SBC3
Charging base

61

TiR32/TiR29/TiR27 Building
Diagnostic Thermal Imagers
The New P3 Series from Fluke
Designed specifically for the building inspection professional, the Fluke P3 Series
of thermal imagers deliver the perfect balance between performance and price.
They also boast superior infrared resolution, spatial resolution, and high definition
displays. The P3 Series delivers crisp images and impressive reports with the
included professional SmartView software. Whether youre searching for energy
waste, leaky roofs or moisture problems, Fluke P3 thermal imagers offer tested and
proven technology that takes the guesswork out of finding problems and provides
solutions.

Fluke TiR32

Superior image quality

New

Delivers the clear, crisp images needed to find problems fast


Identify even the smallest temperature differences that could indicate problems
with industry-leading thermal sensitivity (NETD), down to 40 mK.
Automatic alignment (parallax correction) of visual and infrared images with Fluke
patented IR-Fusion
Optional telephoto and wide angle lenses available for added versatility and special
applications (easily installable in the field).

Easy to use

Fluke TiR29

New

Field replaceable batteries give you maximum flexibility no matter where your work
takes you.
Intuitive, three-button menu is easy to usesimply navigate with the push of a
thumb.
No need to carry pen and paperrecord findings by speaking into the imager. Voice
annotations can be recorded with every image you take. Voice comments are saved
along with individual images for future reference.
One-handed focus capability, emissivity correction, reflected background
temperature compensation, and transmission correction increase the accuracy of
measurements in most situations.
Adjustable hand strap for left-or right-handed use.
Everything needed to get started is included.

Rugged
Optimized for field use in challenging work environments.
Engineered and tested to withstand a 2 m drop for the ultimate peace of mind.
Withstands dust and watertested to an IP54 rating.
With their rugged body, integrated lens cover, protected display and 2 meter drop
test, they are designed to handle the harshest environments.

www.chorus.ro
Fluke TiR27

62

TiR32/TiR29/TiR27 Building
Diagnostic Thermal Imagers
Specifications

Thermal imaging performance


Detector type

Fluke TiR27

Fluke TiR29

Fluke TiR32

240 x 180 Focal Plane Array,


uncooled microbolometer

280 x 210 Focal Plane Array,


uncooled microbolometer

320 x 240 Focal Plane Array,


uncooled microbolometer

Field of view (FOV)


Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (auto/manual)
Focus
Optional telephot infrared lens type
Field of view (FOV)
Minimum focus distance
Optional wide-angle infrared lens type
Field of view (FOV)
Minimum focus distance
Visual imaging performance
Minimum focus distance
On camera operating modes
Color Alarm
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes
Ultra Contrast Palettes
Voice Annotation
Voice annotation
Image and data storage
Storage medium
File formats supported
Controls and adjustments
Set-up controls

23 horizontal x 17 vertical
1.49 mRad
15 cm
0.045 C at 30 C (50 mK)
2.5 C / 5 C
Manual

1.67 mRad

1.25 mRad
0.040 C at 30 C (40 mK)

11.5 x 8.7
45 cm
46 x 34
7.5 cm
46 cm
Picture-in-Picture and full screen IR plus Blending
Dewpoint alarm
2.0 MegaPixel
-20 C to 150 C
2 C or 2%
Center point and hot and cold markers
9.1 cm (3.7) landscape color VGA (640x480) LCD
Selectable bright or auto
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
O

2GB SD Card (3000 .bmp IR images/1200 .IS2 images)


JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, C/F, language
On screen emissivity correction
On-screen reflected background temperature compensation
On-screen transmission correction

Language selection
Image controls
Power
Battery type
Battery operating time

Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling
Two replaceable rechargeable battery packs (Lithium ion)
4+ hours per battery pack

Water and dust resistant: IP54


Size (HxWxD): 277 x 122 x 170 mm
Weight: 1.05 kg
Two Years Warranty
Complete package

Included Accessories
SmartView software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery (extra)
AC charger/power supply
User manual

FLK-LENS/TELE1
Telephoto Infrared Lens

Ordering Information
Fluke TiR27 Thermal Imager for
Building Diagnostics
Fluke TiR29 Thermal Imager for
Building Diagnostics
Fluke TiR32 Thermal Imager for
Building Diagnostics

www.chorus.ro

FLK/LENS/WIDE
Wide-angle Infrared Lens

Recommended Accessories

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery

FLK-TI-SBC3
Charging base

63

Ti125/Ti110/Ti100 Industrial /
Commercial Thermal Imagers
Industrial and commercial maintenance
made easy

New

Technology isnt working for you if its slowing you down. Fluke proudly introduces
five new thermal imagers specifically designed to help you do more in less time,
while being at home in the harshest of environments. A project that might normally
take an hour can now be done in minutes. Our newest imagers are the lightest, most
rugged, easiest-to-use professional imagers you can buy.

IR-OptiFlex focus system


Discover issues significantly faster with Flukes revolutionary, ultra-rugged focus
system. The IR-OptiFlex focus system gives you optimum focus by combining
focus-free ease-of-use with the flexibility of manual focus on the same camera!
Ti125

IR-Fusion technology
Enjoy the industrys best point-and-shoot IR-Fusion camera. Fluke patented
technology blends digital and infrared images into a single image to precisely
document problem areas.

Rugged one-hand operation


Experience the most rugged and reliable, lightweight professional camera around.
One-touch focus, laser pointer, and torch. Point-and-shoot simplicity. No one builds
more rugged, ergonomic tools than Fluke.

Ti110

Multi-mode video recording


Troubleshoot with the industrys only thermal imager that records focus-free video in
visible light and infrared with full IR-Fusion capabilities. Monitor processes over time,
easily create infrared video reports, and troubleshoot.

IR-PhotoNotes annotation system


Get an exact reference to your problem area by capturing up to three digital photos
per file. Add images of equipment, motor nameplates, workroom doors or any other
useful or critical information.

Electronic compass
Ti100

64

Make sure you and others know the location of the problem. Compass readings easily
appear in images and reports.

www.chorus.ro

Ti125/Ti110/Ti100 Industrial /
Commercial Thermal Imagers
Specifications
Fluke Ti125
Fluke Ti110
Industrial-Commercial
Thermal imaging performance
IR resolution (FPA size)
Field of view (FOV)
Spatial resolution (IFOV)
Thermal sensitivity (NETD)

160 x 120 FPA Uncooled Microbolometer


22.5 H x 31 V
3.39 mRad
0.10 C at 30 C target temp (100 mK)

Minimum span in auto mode


Minimum span in manual mode
Minimum IR focus distance
Focus mechanism

5 C
2.5 C
15.25 cm (6 in)
IR-OptiFlex focus system
PIP, FULL IR, FULL VISIBLE,
AutoBlend

PIP, FULL IR, FULL VISIBLE

No, full IR only

Color alarms

High temperature,
low temperature, isotherm

High temperature

Multi-mode video recording


(radiometric .IS3)

2 megapixel industrial-grade
3.5 inch diagonal (portrait format)
Yes
Three on camera and in SmartView
Yes
Manual and auto
Yes (3 images)
Yes
Yes
Yes
Yes
Yes
Streaming USB video output
Yes (AVI with MPEG encoding)
Yes, radiometric .is3 for
approx.. 2.5 to 5 minutes
depending upon thermal
scene

Temperature measurement
Temperature measurement range
(not calibrated below -10 C)

Ultra Contrast palettes

n/a

in SmartView only

-20 C to +350 C

Accuracy
Image presentation
Standard palettes

SmartView software
AC power adapter
Lithium ion smart battery
USB cable
2 GB SD memory card
Hard carrying case
Soft transport bag
Adjustable hand strap
User manual
Two-bag charging base and multi-format USB
memory card reader (Ti125 only)

1.2 m (4 ft)
Focus-free 1.2 m and
beyond

IR-Fusion technology

Visual imaging performance


Visible camera
LCD display
Hot/Cold markers
User definable spot markers
Centerbox (MIN/AVG/MAX)
Level and span control
IR-PhotoNotes annotation system
Laser pointer
Torch
Electronic (cardinal) compass
Emissivity correction
Transmission correction
Video
Multi-mode video output
Multi-mode video recording
(standard AVI with MPEG encoding)

Included Accessories

Fluke Ti100
General

-20 C to +250 C

2 C or 2 % (at 25 C nominal, whichever is greater)


Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Hot Metal, Ironbow, Amber, Inverted Amber
Blue-Red, Grayscale,
Inverted Grayscale,
High-contrast, Hot Metal,
Ironbow, Amber,
Inverted Amber

Voice Annotation
Voice annotation
Image and data storage
Memory storage
Power
Battery
(field-replaceable, rechargeable)
Battery life

Blue-Red, Ironbow,
Grayscale, Amber

Blue-Red, Grayscale,
Ironbow

Yes (60 seconds) per image

2 GB SD memory card
Two

One
4+ hours (each) (assumes 50% brightness of LCD)

Water and dust resistant: IP54


Size (HxWxD): 284 x 86 x 135 mm
Weight: 0.726 kg
Two Years Warranty

Ordering Information
Fluke Ti125
Fluke Ti110

Industrial-Commercial
Thermal Imager
Industrial-Commercial
Thermal Imager
General Use Thermal
Imager

www.chorus.ro
Fluke Ti100

Recommended Accessories

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery

FLK-TI-SBC3
Charging base

65

TiR125/TiR110/Ti100 Building
Diagnostic Thermal Imagers
Building diagnostics made easy

New

Technology isnt working for you if its slowing you down. Fluke proudly introduces
five new thermal imagers specifically designed to help you do more in less time,
while being at home in the harshest of environments. A project that might normally
take an hour can now be done in minutes. Our newest imagers are the lightest, most
rugged, easiest-to-use professional imagers you can buy.

IR-OptiFlex focus system


Discover issues significantly faster with Flukes revolutionary, ultra-rugged focus
system. The IR-OptiFlex focus system gives you optimum focus by combining
focus-free ease-of-use with the flexibility of manual focus on the same camera!

TiR125

IR-Fusion technology
Enjoy the industrys best point-and-shoot IR-Fusion camera. Fluke patented
technology blends digital and infrared images into a single image to precisely
document problem areas.

Rugged one-hand operation


Experience the most rugged and reliable, lightweight professional camera around.
One-touch focus, laser pointer, and torch. Point-and-shoot simplicity. No one builds
more rugged, ergonomic tools than Fluke.

Multi-mode video recording


TiR110

Troubleshoot with the industrys only thermal imager that records focus-free video in
visible light and infrared with full IR-Fusion capabilities. Monitor processes over time,
easily create infrared video reports, and troubleshoot.

IR-PhotoNotes annotation system


Always have references handy IR-PhotoNotes annotation system quickly
identify and keep track of inspection locations by adding digital images of important
information and surrounding areas (TiR110 and TiR125).

Electronic compass
Make sure you and others know the location of the problem. Compass readings easily
appear in images and reports.
Ti100

66

www.chorus.ro

TiR125/TiR110/Ti100 Building
Diagnostic Thermal Imagers
Specifications
Fluke TiR125
Fluke TiR110
Building diagnostics
Thermal imaging performance
IR resolution (FPA size)
Field of view (FOV)
Spatial resolution (IFOV)
Thermal sensitivity (NETD)

160 x 120 FPA Uncooled Microbolometer


22.5 H x 31 V
3.39 mRad
0.08 C at 30 C target temp (80 mK)
0.10 C at 30 C target
temp (100 mK)

Minimum span in auto mode


Minimum span in manual mode
Minimum IR focus distance
Focus mechanism
IR-Fusion technology
Color alarms

Visual imaging performance


Visible camera
LCD display
Hot/Cold markers
User definable spot markers
Centerbox (MIN/AVG/MAX)
Level and span control
IR-PhotoNotes annotation system
Laser pointer
Torch
Electronic (cardinal) compass
Emissivity correction
Transmission correction
Video
Multi-mode video output
Multi-mode video recording
(standard AVI with MPEG encoding)
Multi-mode video recording
(radiometric .IS3)

2.5 C
2.0 C
15.25 cm (6 in)
IR-OptiFlex focus system
PIP, FULL IR, FULL VISIBLE

No, full IR only

High temperature,
low temperature (dewpoint),
and isotherm

Low temperature
(dewpoint)

2 megapixel industrial-grade
3.5 inch diagonal (portrait format)
Yes
Three on camera and in SmartView
Yes
Manual and auto
Yes (3 images)
Yes
Yes
Yes
Yes
Yes
Streaming USB video output
Yes (AVI with MPEG encoding)
Yes, radiometric .is3 for
approx.. 2.5 to 5 minutes
depending upon thermal
scene

SmartView software
AC power adapter
Lithium ion smart battery
USB cable
2 GB SD memory card
Hard carrying case
Soft transport bag
Adjustable hand strap
User manual
Two-bag charging base and multi-format USB
memory card reader (Ti125 only)

n/a

in SmartView only

-20 C to +150 C

Accuracy
Image presentation
Standard palettes

Included Accessories

5 C
2.5 C
1.2 m (4 ft)
Focus-free 1.2 m and
beyond

PIP, FULL IR, FULL VISIBLE,


AutoBlend

Temperature measurement
Temperature measurement range
(not calibrated below -10 C)

Ultra Contrast palettes

Fluke Ti100
General

-20 C to +250 C

2 C or 2 % (at 25 C nominal, whichever is greater)


Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Hot Metal, Ironbow, Amber, Inverted Amber
Blue-Red, Grayscale,
Inverted Grayscale,
High-contrast, Hot Metal,
Ironbow, Amber,
Inverted Amber

Voice Annotation
Voice annotation
Image and data storage
Memory storage
Power
Battery
(field-replaceable, rechargeable)
Battery life

Blue-Red, Ironbow,
Grayscale, Amber

Blue-Red, Grayscale,
Ironbow

Yes (60 seconds) per image

2 GB SD memory card
Two

One
4+ hours (each) (assumes 50% brightness of LCD)

Water and dust resistant: IP54


Size (HxWxD): 284 x 86 x 135 mm
Weight: 0.726 kg
Two Years Warranty

Ordering Information
Fluke TiR125
Fluke TiR110

Building Diagnostics
Thermal Imager
Building Diagnostics
Thermal Imager
General Use Thermal Imager

www.chorus.ro
Fluke Ti100

Recommended Accessories

Ti-Car Charger
Car charger

FLK-TI-SPB3
Extra battery

FLK-TI-SBC3
Charging base

67

Ti9/Ti10/Ti25 Thermal Imagers


The rugged and affordable tools for
electricians and technicians
Get the full picture instantly with the Fluke Ti9/Ti10/Ti25 thermal imagers. Built for
tough work environments, these fully radiometric imagers are ideal for detecting
problems in a wide range of equipment including switchgear, motor control centers
and lighting systems.

Fluke Ti25

Delivers the clear images to find problems fast with its 160x120 sensor
Even the smallest details become visible with the large, widescreen full color
LCD display
Optimized for field use in harsh work environments
- Engineered and tested to withstand a 2 meter drop
- Withstands dust and water tested to an IP54 rating
- Innovative protective lens cover protects the lens when not in use
Enhanced problem detection and analysis capabilities with patent pending
IR-Fusion Technology (Ti10 and Ti25)
Intuitive, three-button menu is easy to use ... simply navigate with the push
of a thumb
Store more than 3.000 screen images (.bmp format) or 1.200 fully radiometric
images (.IS2 format) on included 2 GB SD memory card

IR-Fusion Technology
Fluke Ti10

See things both waysinfrared and visual (visible light) images fused together
communicating critical information faster and easiertraditional infrared images
are no longer enough. IR-Fusion, a patent-pending technology that simultaneously
captures a digital photo in addition to the infrared image and fuses it together taking
the mystery out of IR image analysis. IR-Fusion is standard on Ti10 and Ti25 models.
The Fluke Ti9 can be upgraded to a full Fluke Ti10 with IR-Fusion at a later time.

Fluke Ti9

68

www.chorus.ro

Ti9/Ti10/Ti25 Thermal Imagers


Specifications
Fluke Ti9
Thermal imaging performance
Detector type
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Thermal sensitivity (NETD)
Minimum span (auto/manual)
Focus
Visual imaging performance
Minimum focus distance
On camera operating modes
Visible light camera
Temperature measurement
Temperature range
Accuracy
Measurement modes
Image presentation
Digital display
LCD backlight
Palettes

Image and data storage


Storage medium
File formats supported
Controls and adjustments
Set-up controls

Language selection
Image controls
Power
Battery type
Battery operating time

Fluke Ti10

Fluke Ti25

160 x 120 Focal Plane Array, uncooled microbolometer


23 horizontal x 17 vertical
2.5 mRad
15 cm
0.2 C at 30 C (200 mK)
0.13 C at 30 C (130 mK)
0.09 C at 30 C (90 mK)
10 C / 5 C
10 C / 5 C
2.5 C / 5 C
Manual
46 cm
Picture-in-Picture and full
screen IR plus

-20 C to 250 C
5 C or 5%
Center point

46 cm
Picture-in-Picture and full
screen IR plus Blending

1.3 MegaPixel

1.3 MegaPixel

-20 C to 250 C
2 C or 2%
Center point

-20 C to 350 C
2 C or 2%
Center point and hot and
cold markers

9.1 cm (3.6) landscape color VGA (640x480) LCD


Selectable bright or auto
Ironbow, blue-red, high contrast, grey
Ironbow, blue-red, high
contrast, grey, amber and
hot metal
2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, C/F, language

Date/time, C/F, language


On screen emissivity
correction On-screen
reflected background
temperature compensation

Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling
Internal rechargeable battery NiMh (included)
3 to 4 hours continuous operation

Water and dust resistant: IP54


Size (HxWxD): Ti9/Ti10/Ti25: 267 x 127 x 152 mm
Weight: Ti9/Ti10/Ti25: 1.2 kg
Two Years Warranty

Complete package

Included Accessories
SmartView software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual

Recommended Accessories
Ordering Information
Fluke Ti9
Fluke Ti10
Fluke Ti25

Electrical Thermal Imager


Electrical Thermal Imager
Industrial Thermal Imager

www.chorus.ro

Ti-Visor
Sun Visor
(for complete Ti Series)

Ti-Car Charger
Car charger

69

TiS/TiR/TiRx/TiR1
Thermal Imagers
for Building Diagnostics
Entry-level Thermal Imager

New
Fluke TiS

Flukes entry level thermal imager for quick, easy, and accurate problem identification
and troubleshooting designed specifically for the building inspection professional.
Whether you are a building inspector, plumber, roofer, electrician, energy auditor,
HVAC, insulator, or windows installer the Fluke Thermal Imaging Scanner is the
perfect tool to help you identify hidden building construction issues, find moisture
intrusion, detect energy loss/missing insulation, and many basic electrical connection
and load problems. Now Fluke quality, durability, and performance are available in a
thermal imager engineered for the valueconscious building professional. The Fluke
TiS Thermal Imaging Scanner is the top-performing imager in its price class.
Highest resolution (120x120) in price class
Only imager in price class with versatile, manual focus
Largest display size (3.7) in price class.
Long battery life lasts ~4 hours
Rugged body engineered to withstand 2 m drop test
Easy to usethe TiS Thermal Imaging Scanner provides you with a basic,
reliable solution for the building professional
NETD 100 mK

Optimized for energy audits, restoration and


remediation

Fluke TiR

The affordable rugged Fluke TiRx and TiR Thermal Imagers are workhorse tools
for the demands of building envelope, restoration and remediation, inspection
and roofing applications. Whether to perform energy audits, locate the origins of
construction problem or to find roof leaks, the TiRx and TiR offer an economical
solution for complete detection, analysis and documentation.
Delivers the clear images to find problems fast with its 160x120 sensor
Enhanced problem detection and analysis capabilities with patent pending
IR-Fusion Technology (TiR)
The Fluke TiRx can be upgraded to a full Fluke TiR with IR-Fusion at a later time.
NETD 90 mK

Fluke TiRx

The professionals choice


The TiR1 Thermal Imager is the professionals choice for building diagnostics. The
Fluke TiR1 has all the features of the Fluke TiR, but with an NETD of 0.07C for the
TiR1 to identify even small temperature differences that could indicate problems.
IR-Fusion, full option (combines visible image with IR image in full screen or
picture-in-picture views)
Voice recording; record findings by speaking into the camera. Voice annotations
can be recorded with every image you take. Voice comments are saved along with
individual images for future reference
NETD 70 mK

70

www.chorus.ro
Fluke TiR1

TiS/TiR/TiRx/TiR1
Thermal Imagers
for Building Diagnostics
Specifications
Fluke TiS
Thermal imaging performance
Detector type

Field of view (FOV)

23 horizontal x 17 vertical

0.1 C at 30 C
(100 mK)

0.09 C at 30 C
(90 mK)

5 C (in auto mode)

0.07 C at 30 C
(70 mK)

2.5 C / 5 C (Auto/Manual)
Manual
46 cm
Picture-in-Picture and full screen IR

Picture-in-Picture and
full screen IR plus
Blending

1.3 MegaPixel
-20 C to 100 C
5 C or 5%
Center point

Image presentation
Digital display

-20 C to 150 C
2 C or 2%
Center point and hot
and cold markers

9.1 cm (3.6) landscape color VGA (640x480) LCD

LCD backlight

Selectable bright or auto


Ironbow, blue-red,
greyscale

Image and data storage


Storage medium
File formats supported
Controls and adjustments
Set-up controls

Language selection
Image controls

Fluke TiR1

2.5 mRad
15 cm

Visible light camera


Temperature measurement
Temperature range
Accuracy
Measurement modes

Palettes

Fluke TiR

160 x 120 Focal Plane Array, uncooled microbolometer

17 horizontal x 17
vertical

Spatial resolution (IFOV)


Min focus distance
Thermal sensitivity (NETD)
Minimum span
Focus
Visual imaging performance
Minimum focus distance
On camera operating modes

Fluke TiRx

120 x 120 Focal Plane


Array, uncooled
microbolometer

Ironbow, blue-red, high contrast, grey

Ironbow, blue-red, high


contrast, grey, amber
and hot metal

2GB SD Card (3000 .bmp IR images/1200 .IS2 images)


JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Date/time, C/F, language

Smooth auto-scaling
and lock of level and
span

Power
Battery type
Battery operating time

Date/time, C/F, language


On screen emissivity
correction On-screen
reflected background

Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Smooth auto scaling and manual scaling

Internal rechargeable battery NiMh (included)


3 to 4 hours continuous operation

Water and dust resistant: IP54


Size (HxWxD): 267 x 127 x 152 mm
Weight: 1.2 kg
Two Years Warranty
Complete package

Included Accessories
SmartView software
2 GB SD card
SD card reader
Rugged hard carrying case
Soft carrying case
Hand strap
Rechargeable battery
AC charger/power supply
User manual

Ordering Information
Fluke TiS
Fluke TiRx
Fluke TiR

Thermal Imaging Scanner


Inspector Thermal Imager
Thermal Imager for Building
Diagnostics
Thermal Imager for Building
Diagnostics

www.chorus.ro
Fluike TiR1

Recommended Accessories

Ti-Visor
Sun Visor
(for complete Ti Series)

Ti-Car Charger
Car charger

FLK-TI-SBC3
Charging base (Ti32)

71

CRange IRWindows
Increase the safety and speed of electrical
thermography
Infrared windows mount into panel doors
and covers for switchgear, transformers,
bus bars and other live electrical
equipment, allowing Infrared, Ultraviolet,
Visual and IRfusion technologies to be
used without exposing personnel to live
equipment.
All infrared windows from Fluke use
the unique Quadraband multispectral
optic, allowing inspection with any
camera for total flexibility both now and
in the future.

Reduce the arc flash risk associated


with electrical thermography
Increase efficiency as thermographer
can work alone without being
accompanied by an electrician to isolate
and open panels
Stay safety compliant with NFPA70E
and other safety protocols and leave the
panels closed
Extend the life of your equipment with
more frequent IR scans
Easy to install
Durable enough to withstand extreme
outdoor conditions yet practical for
indoor applications as well.

Specifications
(Check the Fluke web for detailed specifications)

Included Accessories
Installation CD, self-adhesive drilling
template, security access key, warranty
statement.

Ordering Information
FLK-075-CLKT
FLK-100-CLKT
IP-200-UK

72

75mm C-Range IR Window,


Kwik Twist
100mm C-Range IR Window,
Kwik Twist
Window Installation Kit
220/240V

Optic Data
Crystal Insert Diameter
Viewing Aperture Diameter
Viewing Aperture Area
Thickness
CLIRVU Coating
Shortwave IR Capable
Midwave IR Capable
Longwave IR Capable
Ultraviolet (UV) Capable
Visual Capable
Fusion Capable
General
Maximum Temperature
Gaskets
Body
Optic
Gaskets
IP rating
NEMA rating
Vibration rating
Humidity rating
Pull out strength

FLK-075-CLKT

FLK-100-CLKT

75 mm
68 mm
3632 mm2
2 mm

100 mm
89 mm
6322 mm2
4 mm

O
O
O
O
O
O
O

O
O
O
O
O
O
O

250 C
659 C
1400 C
Low Smoke & Fume (LSF) compliant silicone
IP65
Typo 3/12 (UL & CSA Third Party Certified)
IEC60068-2-6
IEC60068-2-3
Up to 630 kg

Warranty: Lifetime replacement against manufacturing defects

www.chorus.ro

Laser Distance Meters


The Fluke Laser Distance Meters bring you the most advanced
measuring technology. Unlike ultrasonic distance meters with laser
pointers, these meters use a precision narrow laser beam that can
avoid the common errors caused by extraneous objects near
measurement targets.

www.chorus.ro

73

421D, 416D, 411D


Laser Distance Meters
Professional-grade laser distance
measuring tools that are fast, easy to use,
and t in your pocket.
The Fluke laser distance meters bring you
the most advanced measuring technology.
These meters are fast, accurate, durable,
and easy to use just point and shoot.
Their straightforward design and easy,
one-button operation mean you spend less
time measuring. Unlike ultrasonic distance
meters with laser pointers, the Fluke 421D,
416D and 411D use a precision narrow
laser beam that can avoid the common
errors caused by extraneous objects near
measurement targets.

These compact and handy Fluke distance


meters are designed for indoor, and limited
outdoor applications. Addition, subtraction,
area, and volume calculations could not
be simpler. The extra bright laser is clearly
visible so you can see your targeting point
even if an object is hard-to-reach or distant.
The Fluke 421D, 416D and 411D have a large
LCD screen and buttons positioned for onehanded measurements.

Features

Fluke 421D
411D

416D

421D

Reduction of estimation errors, saving both time and money

Instant measurement with one-button operation

Easy targeting with bright laser

Quick calculation of area (square footage) and volume

Easy addition and subtraction of measurements

Improved battery life from automatic shut-off feature

Pythagoras calculation for determining distance indirectly from two


other measurements

Pouch

30 m

60 m

100 m

10

20

MIN/MAX function

Enhanced Pythagoras calculation for determining distance indirectly from three other measurements

Audible feedback of on and off modes

Strong environment protection with IP54 (water spray & dust proof)
sealing

Ability to view more with large, 3-line display with backlight


Ability to measure up to
Storage capacity of measurements for quick recall of distance

Fluke 411D

Fluke 416D

Audible feedback for taking room angle and incremental measurements

45 Tilt sensor for taking indirect measurements in hard to reach areas

Tripod mode allows you to mount to a tripod for measuring long


distances

Built in light sensor for activating the backlight saving battery life

Corner angle feature, allows you to determine the angle of a corner

Specications
(Check the Fluke web for detailed specications)

Range (for extended distances, use a target plate)


Accuracy

411D/62 Kit
Combo kit includes:
- Fluke 62 Mini IR Thermometer
- Fluke 411D Laser Distance Meter
- Soft pouch for each model

Included Accessories

Two AAA batteries, Users manual on CD,


Quick start guide, Nylon carrying case,
Wrist wrap (421D)

Measurement units

Fluke 411D

Fluke 416D

30 m

60 m

100 m

3 mm

1.5 mm

1.5 mm

00.000 m

Measurement storage
Backlight
Automatic power off

Operating temperature: 0C to 40C


Storage temperature: -25C to 70C
Operating altitude: up to 3500 m
Battery Life: 411D: up to 3000 readings
416D, 421D: up to 5000 readings

www.chorus.ro

After 180 seconds

Fluke 421D

00.000 m

00.000 m

10 locations

20 locations

After 180 seconds

After 360 seconds

Size (HxWxD):
411D: 123 mm x 50 mm x 26 mm
416D: 135 mm x 46 mm x 31 mm
421D: 127 mm x 52 mm x 25 mm
Weight:
411D: 0.150 kg
416D: 0.110 kg
421D: 0.125 kg
Warranty: 2 years

Ordering Information

74

Fluke 411D
Fluke 416D
Fluke 421D

Laser Distance Meter


Laser Distance Meter
Laser Distance Meter

65

Indoor Air Quality Tools


In response to the growing importance of air quality in buildings,
workplaces and homes, Fluke offers you a range of tools that monitor
temperature, humidity, air velocity, particulate, and carbon monoxide
levels. These tools help you to quickly and easily troubleshoot and
maintain indoor air quality, as well as to verify the efficient operation of
heating, ventilation and air conditioning systems.

www.chorus.ro

75

975 AirMeter
Combined inspection tool for complete air
quality inspections
The Fluke 975 AirMeter combines five air
monitoring tools into one, rugged and
easy-to-use handheld tool. Use the Fluke
975 to verify the efficient operation of
heating, ventilation and air conditioning
systems, and test for dangerous carbon
monoxide leaks in all types of buildings.

Simultaneously measures, logs, and


displays temperature, humidity, CO2,
and CO on a bright, backlit LCD display
One-touch air flow and velocity
measurements with available probe
Min/Max/Average on all measured and
calculated readings
Audible and visual threshold alarms
Multi-language user interface
Extensive discrete or continuous data
logging capacity, down-loadable to PC
via USB interface

Specifications
(Check the Fluke web for detailed specifications)
Feature
Measured specifications
Temperature

Range

Display resolution

Accuracy

-20 C to 60 C

0.1 C

10 % to 90 % RH noncondensing
50 fpm to 3000 fpm
0.25 m/sec to 15 m/sec

1 fpm
0.005m/sec

CO2

0 to 5000 ppm

1 ppm

CO

0 to 500 ppm

1 ppm

0.9 C from 40 C to 60 C
0.5 C from 5 C to 40 C
1.1 C from -20 C to 5 C
2 % RH (10 % RH
to 90 % RH)
4 % or 4 fpm*
3 % or 0.015 m/sec*
whichever is greater
*Accuracy specification only valid
for velocity readings above 50 fpm.
Warm up time 1 min
(5 minutes for full specification)
2.75 % + 75 ppm
5 % or 3 ppm,
whichever is greater,
@ 20 C and 50 % RH

Calculated specifications
Dew point temperature

-44 C to 57 C

0.1 C

Wet bulb temperature

-16 C to 57 C

0.1 C

0 to 3,965 M3/m 0 to
140,000 cfm)

0.001 M3/min (1 cfm)

0 to 100 %
0 to 100 %

0.1 %
0.1 %

Relative humidity
Air velocity

1%

Fluke 975

Volume flow rate (in a duct)

% outside air (based on temperature)


% outside air (based on CO2)

Operating temperature
(CO and CO2 sensors): -20 C to 50 C
Operating temperature
(all other functions): -20 C to 60 C
Storage temperature: -20 C to 60 C
Humidity: 10% to 90%
Altitude: Up to 2000 m

Included Accessories

1 C when temp: -20 C to 60 C


RH: 40 % to 90 %
2 C when temp: -20 C to 60 C
RH: 20 % to 40 %
4 C when RH: 10 % to 20 %
1.2 C when RH: 20 % to 90 %
temp: -20 C to 60 C
2.1 C when RH: 10 % to 20 %
N/A: The volume flow
calculation will be a simple average
of the data points times the
duct area
N/A
N/A

Shock and vibration: MIL-PRF-28800F, Class 2


Battery: Rechargeable Li-Ion (primary), threeAA (backup)
Weight: 0.544 kg
Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm
Data logging: 25,000 records (continuous),
99 records (discrete)
Multilanguage interface: English, French,
Spanish, Portuguese and German
Two-year warranty

A4 alkaline batteries (3), Users Manual,


Calibration Cap, FlukeView Forms Software,
Power Adapter, International Power Plugs,
Air Velocity Probe (Fluke 975V only)

Ordering Information
Fluke 975
Fluke 975V
975R
975VP

76

Recommended Accessories

AirMeter
AirMeter with Velocity
Regulator
Air Velocity Probe

www.chorus.ro

975VP
AirMeter Velocity Probe

922 Airflow Meter


Measures pressure, air flow and velocity for
maintaining balanced and comfortable
ventilation
The Fluke 922 makes airflow
measurements easy by combining
pressure, air flow, and velocity into a
single, rugged meter. Compatible with
most Pitot tubes, the Fluke 922 allows
technicians to conveniently enter
their duct shape and dimensions for
maximum measurement accuracy.

Provides differential and static pressure,


air velocity and flow readings
Convenient colored hoses help you
properly diagnose pressure readings
Bright, backlit display for clear viewing
in all environments
Min/Max/Average/Hold functions for
easy data analysis
Auto power off saves battery life

Use the Fluke 922 to: Ensure proper air


flow balance and maintain a comfortable
environment; measure pressure drops
across filters and coils; match ventilation
to occupant loads; monitor indoor vs.
outdoor pressure relationships and
manage the building envelope; and
perform duct traversals for accurate
airflow readings.

Specifications
(Check the Fluke web for detailed specifications)
Feature

Range

Resolution

Accuracy

Operating Specifications

Air Pressure

Air Velocity
Fluke 922

Air Flow (Volume)

Temperature

4000 Pascals
16 in H2O
400 mm H2O
40 mbar
0.6 PSI
250 to 16,000 fpm
1 to 80 m/s
0 to 99,999 cfm
0 to 99,999 m3/hr
0 to 99,999 l/s
0 C to 50 C

1 Pascal
0.001 in H2O
0.1 mm H2O
0.01 mbar
0.0001 PSI
1 fpm
0.001 m/s
1 cfm
1 m3/hr
1 l/s
0.1C

1% +1 Pascal
1% + 0.01 in H2O
1% + 0.1 mm H2O
1% +0.01 mbar
1% + 0.0001 PSI
2.5 % of reading at 10 m/s
(2000 p/min)
Accuracy is a function of
velocity and duct size
1 % + 2 C

General Specifications
General specifications
Operating Temperature
Storage Temperature
Operating Relative Humidity

IP Rating
Operating Altitude
Storage Altitude
EMI, RFI, EMC
Vibration
Max Pressure at Each Port

Included Accessories
Fluke 922: Two Rubber Hoses, Wrist Strap, Four
AA Batteries 1.5 V Alkaline, Users Manual and
Soft Carrying Case
Fluke 922 Kit Includes: Fluke 922 Airflow Meter,
30.48 cm Pitot tube, ToolPak, Two Rubber
Hoses, Wrist Strap, Four AA Batteries 1.5 V
Alkaline, Users Manual and Hard Carrying
Case

Data Storage: 99 readings


Size (HxWxD): 175 x 775 x 419 mm
Weight: 0.64 kg
Battery: Four AA batteries
Battery Life: 375 hours without backlight,
80 hours with backlight
Two Year Warranty

Ordering Information
Fluke 922
Fluke 922/Kit

0 C to +50 C
-40 C to +60 C
Non condensing (<10 C)
90% RH (10 C to 30 C)
75% RH (30 C to 40 C)
45% RH (40 C to 50 C) Without Condensation
IP40
2000 m
12000 m
Meets requirements for EN61326-1
MIL-PREF-28800F, Class 3
10 PSI

Fluke 922/Kit

Recommended Accessories

Air Flow Meter


Airflow Meter with
30.48 cm Pitot Tube

www.chorus.ro

PT12
Pitot Tube, 30.48 cm

TPAK
Toolpak
See page 132

77

971 Temperature Humidity Meter


Carbon Monoxide Meters
Fluke 971
Temperature Humidity Meter
Quickly take accurate humidity and
temperature readings in the air.
Temperature and humidity are two
important factors in maintaining
optimal comfort levels and good indoor
air quality. The Fluke 971 is invaluable
for facility maintenance and utility
technicians, HVAC-service contractors,
and specialists who assess indoor air
quality (IAQ). Lightweight, rugged, and
easy to hold, the Fluke 971 is the perfect
tool for monitoring problem areas.

Simultaneously measures humidity and


temperature
Measures dew point and wet bulb
99 record storage capacity
Min/Max/Avg Data Hold
Ergonomic design with built-in belt clip
and protective holster
Backlit, dual readings display
Twist-open protective cap
Low battery indicator

Specifications

Fluke 971

Other useful tools

Fluke 561

Fluke 416D

Combined Contact
and Non-contact
Thermometer
See page 54.

Laser Distance Meter


See page 74 .

Temperature range
Temperature accuracy
0 C to 45 C
-20 C to 0 C and 45 C to 60 C
Resolution
Response time (temperature)
Temperature sensor type
Relative humidity range
Relative humidity accuracy
10% to 90% R.H. @ 23 C
<10%, >90% R.H. @ 23 C
Humidity sensor
Data storage
Response time (humidity)

-20 C to 60 C
0.5 0C
1.0 C
0.1 C
500 ms
NTC
5% to 95% R.H.
2.5 % R.H.
5.0 % R.H.
Electronic capacitance polymer film sensor
99 points
For 90% of total range - 60 sec with 1 m/s air movement

Operating temperature:
Temperature: -20 C to 60 C
Humidity: 0 C to 60 C
Storage temperature: : -20 C to 55 C
Battery life: 4 AAA alkaline, 200 hours

Safety: Complies with EN61326-1


Weight: 0.188 kg
Size (HxWxD): 194 mm x 60 mm x 34 mm
One Year Warranty

Carbon Monoxide Meters


CO-220 Carbon Monoxide Meter

Included Accessories
Fluke CO-220:

C50 soft carrying case and


battery

The CO-220 Carbon Monoxide Meter makes it easy to take quick


and accurate measurements of CO levels. A large, backlit LCD
display shows CO levels from 0 to 1000 PPM. The MAX Hold
function stores and displays the maximum CO level.
1 year warranty.

Fluke CO-220

Ordering Information
Fluke 971
Fluke CO-220
CO-205

78

Temperature Humidity
Meter
Carbon Monoxide Meter
Aspirator Kit

CO-205 Aspirator Kit


Allows flue gas samples up to 371C to be drawn with the
CO-220 for carbon monoxide measurement.
1 year warranty.

www.chorus.ro

Fluke CO-205

983 Particle Counter /


RLD2 Leak Detector Flashlight
Easy to use tool for troubleshooting and
maintaining indoor air quality
The Fluke 983 Particle Counter
simultaneously measures and displays
six channels of particle size distribution,
temperature and humidity. This compact,
lightweight, self-contained tool allows
for one-handed operation. As the Fluke
983 doesnt require level holding, it can
make accurate measurements in any
position. The 8 hour rechargeable battery
together with a large 5000 sample record
allows for complete air quality surveys in
one go. The Fluke 983 is the ideal tool for
determining size distribution of airborne
particles or tracking down a particle
source.

Simultaneously measure and display 6


channels of particle sizes, temperature
and humidity
Measure particle size down to 0.3 m
Selectable sample time, count data,
programmable delay
Store 5000 records of date, time, counts,
relative humidity, temperature, sample
volumes, alarms and location label
Upload stored data to a PC with
included software
Compact, self-contained package allows
for one-handed operation
Intuitive, easy-to-use user interface
Always ready to run, with no fluids to
refill
Backlit LCD for use in any lighting
condition

Specifications

Fluke 983

6 size channels
Flow rate
Count modes
Counting efficiency
Zero count
Coincidence loss
Relative humidity
Temperature
Data storage
Alarms
Delay time
Sample inlet
Interface
Calibration

0.3, 0.5, 1.0, 2.0, 5.0, 10.0 m


0.1 cfm (2.83 L/min) controlled by internal pump
Concentration, totalize, audio
50 % @ 0.3 m; 100 % for particles > 0.45 m (per JIS B9921:1997)
1 count/5 minute (per JIS B9921:1997)
5 % at 56,000 particles per m3
7 %, 20 % to 90 %, non-condensing
3 C, 10 C to 40 C
5000 sample records (rotating buffer) of date, time, counts, relative humidity,
temperature, sample volumes, alarms, label
Counts, low battery, sensor fail
0 to 24 hours
Isokinetic probe
RS-232 and RS-485 via RJ-45
PSL particles in air (NIST traceable)

Operating temperature: 10 C to 40 C, 20 % to
90 % relative humidity, non-condensing
Storage temperature: -10 C to 50 C, up to
90 % relative humidity, non-condensing
Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz
Battery life/recharge time: 8 hours/2 hours

Included Accessories
Fluke 983:
Certificate of Calibration (NIST)
Isokinetic probe
Zero count filter
Windows-compatible software download
utility
DB9 to RS-232 adapter and cable
High purity tubing
1/8 in. hose barb adapter
Power supply
Operation manual
Hard molded carrying case
Fluke RLD2: Key chain carabiner and batteries.

Ordering Information

www.chorus.ro
Fluke 983
Particle Counter
Fluke RLD2 Leak Detector Flashlight

Rechargeable battery: NiMH, 4.8V at 4.5 Ah;


replaceable
Size (HxWxD): 209 mm x 114 mm x 57 mm
Weight: 1 kg
Warranty: 1 year

RLD2 Leak Detector Flashlight

RLD2 Leak Detector Flashlight.


Leak detection made easy. The compact RLD2
uncovers refrigerant leaks instantly. Use the UV
light to find the leakage area, then, use the laser
pointer to pinpoint the exact leak location.
Six UV LEDs detect leak detection dyes
Laser pointer clearly locates center of the UV
field for accuracy
Three LED flashlight with 100,000 hour LED life
Operating temperature 0C to 50C
Four operating modes: flashlight, UV light, laser
light, UV/laser light combination
One year warranty

79

ScopeMeter Test Tools


ScopeMeter portable oscilloscopes take you into territory standard
bench scopes cant go: where its harsh, hazardous and dirty without
sacrificing any capabilities. They provide you with unmatched speed,
performance and analysis power while working on site.

80

www.chorus.ro

ScopeMeter 190 Series II


New
The toughest portable scopes ever built
What could you do with four
channels?

Combining rugged portability with the


performance of a bench scope, the Fluke 190
Series can take you from troubleshooting
microelectronics all the way into power
electronic applications. See more, fix more
and go where youve never gone with a scope
before.

The first high-performance two and


four Channel scopes built for harsh
industrial environments.

Introducing the first high-performance portable


oscilloscopes with 2 or 4 independently
insulated input channels, an IP51 dust- and
drip waterproof rating and a CAT III 1000 V /
CAT IV 600 V safety rating. Choose from 500 MHz,
200 MHz, 100 MHz or 60 MHz bandwidth
models.
Now plant maintenance engineers can take
a four-channel scope into the harsh world
of industrial electronics. Safely troubleshoot
three-phase systems like variable speed drives,
UPS or back-up generators. Measure input,
output and feedback signals simultaneously to
diagnose industrial electronics.
4 independent isolated input channels enable
3-axis industrial testing, simultaneous testing
of input signals, output signals and feedback
loops or safety interlocks
190-XX4 model with four independent
isolated inputs
190-XX2 models with two independenet
isolated scope inputs and DMM input
Fast sample rate: up to 5 GS/s with up to
200 ps resolution
Single shot, pulse width and video triggering
Deep memory: 10,000 points per trace
waveform capture
CAT III 1000 V / CAT IV 600 V, safety rated
Up to seven hours of operation with high
performance Li-ion batteries, that extend
usage time plus optional external charger
Battery door for conveniently swapping out
Two isolated USB ports, for memory devices
and PC connectivity
Security slot to lock down instrument using
standard Kensington lock
Connect & View triggering for intelligent,
automatic triggering on fast, slow and even
complex signals
Frequency Spectrum using FFT analysis
Automatic capture and REPLAY of 100 screens
ScopeRecord mode gives 30000 points or
more per input channel for low frequency
signal analysis
TrendPlot paperless recorder mode with
deep memory for long-term automatic
measurements

Technologies
Equipment

Take multiple measurements simultaneously


to track down the root cause of your most
complex troubleshooting challenges.
Easily diagnose timing-related issues with
multiple signals
Real-time inspection of multiple signals
simultaneously
Meaure a combination of input and output
signals and system safety interlocks and
feedback loops

Fluke 190-502 brings wide


bandwidth test applications in the
palm of your hand!

With the new 500 MHz model, the verification


of telecommunication equipment, high
frequency and wide bandwidth systems such
as radar equipment has become truly portable.
Conveniently verify the systems performance
right on the spot, fully safely without carrying
bulky lab equipment around. Battery powered
and fully floating up to 600V CAT III, for each
channel and in between channel references.

Application driven
Find problems in industrial
systems including:

Circuit voltage/current overloading


Attenuation/input impedance mismatch
Signal fluctuation/drift
Conditioning circuits signal integrity
Test point verification for critical signals
Input/output/feedback timing issues
Induced noise and disturbances
Random shutdowns/reset

Diagnose VSDs* or power inverters


and converters

Harmonics, transients and loads in three


phase power input
Troubleshoot dc to ac converters for faulty
control circuits or output IGBT gate stages
Cable interface - test PWM output for
reflections and transients
Vpwm measurement to measure the effective
voltage on drive outputs

Electrical

Electromechanical

Process Controls

Automation

Medical Imaging

Avionics

Switch Gear,
Interlocks,
Motors,
Pumps,
Fans,
Furnaces,
Presses,
Mixers,
Refrigeration

Actuators,
VFD Drives,
Linear Motors,
Pressure-LevelFlow-Position
Sensors,
Packaging
Equipment

Transducers,
Sensors,
Loop Controllers,
Calibrated Gauges

PLCs,
Sensors,
Transducers,
Motion
Controllers,
Rotory
Encoders,
Scanners,
Readers,
Printers

XRay,
MRI,
Ultrasound
Imaging
equipment

Flight Line
Navigation
Systems,
Communication
systems,
Radar,
On board
aircraft control
systems

www.chorus.ro

A/V & Security


Systems
Retail security
devices,
Surveillance and
monitoring
equipment,
RFID

81

ScopeMeter 190 Series II


New

Multiply your diagnostic powers with the new


Fluke 190 Series II portable oscilloscopes
Rated all the way to CAT IV
ScopeMeter test tools are rugged solutions built for industrial troubleshooting. The
new Fluke 190 Series II are double-insulated floating oscilloscopes safety rated for
measurements up to CAT III 1000 V/CAT IV 600 V environments. The new 500 MHz
model is rated all the way up to 600 V CAT III.

Measure from mV to kV safely


Independently isolated inputs allow you to make measurements in mixed circuits
having different ground references reducing the risk of accidental short circuits.
Conventional bench oscilloscopes without special differential probes and isolation
transformers can only reference measurements to line power earth ground. With
standard probes that cover a wide application range from mV to kV, you are ready for
anything from micro-electronics to heavy-duty higher voltage electrical applications.

Fluke 190-204

IP-51 rated for harsh environments


Rugged and shock-proof, ScopeMeter portable oscilloscopes are built for dirty,
hazardous environments. With its sealed case, it can endure dust, drips, humidity and
airborne pollutants. Every time you reach for ScopeMeter you can be confident it will
work reliably wherever your work takes you.

USB connectivity makes it


easy to capture and share
waveforms

Fluke 190-202

True RMS

Optional Accessories
C290

HH290
SCC290
VPS410-R
VPS410-G
VPS410-B
VPS410-V
VPS420-R
BC190
EBC290
TL175
BP290
BP291
SW90W

FlukeView ScopeMeter software for


documenting, archiving and analysis
Get more out of your ScopeMeter with FlukeView ScopeMeter SW90W Software for
Windows.
Documentationtransfer waveforms, screens and data to your PC for printing or
importing data into a report
Add text to ScopeMeter settingsgive operators guidance when recalling settings
Archivecreate a library of waveforms for easy reference, waveform comparison, or
pass/fail testing
Analysisuse cursors, perform spectrum analysis or export data to another
analysis program

www.chorus.ro
VPS510-X

82

Hard shell protective carrying case for


190 Series II
Hanging Hook for 190 Series II
instruments
FlukeView Software (full version) and
C290 Carrying Case kit
Voltage Probe set, 10:1, 300 MHz,
one set red
Voltage Probe set, 10:1, 300 MHz,
one set grey
Voltage Probe set, 10:1, 300 MHz,
one set blue
Voltage Probe set, 10:1, 300 MHz,
one set green
High working voltage probe set 150 MHz,
100:1, CAT III 2000 V (1000 V to earth)
Mains adapter/battery charger
External battery charger for BP290
and BP291
TwistGuard safety designed Test
Leads set (1 red, 1 black)
Li-Ion battery pack, 2400 mAh
Li-Ion battery pack, 4800 mAh
FlukeView ScopeMeter Software for
Windows
Wide bandwidth probe set, 10:1,
500 MHz, 600V CAT III

The new Fluke 190 Series II offers two USB ports,


electrically isolated from measurement input circuits.
Easily transfer data to a PC. Archive and share
waveforms with OEMs, colleagues and support staff.
Store waveforms, screen captures and instrument
setups onto USB memory devices.

ScopeMeter 190 Series II

lic

at

io

Connect-and-View triggering for an instant,


stable display

te

g
fyin

on

No

te

n
A
sti aliesel
plic
io il
Ap
my
is
at a
hann
De anom
eing
ope
ic s/F ke II
2-C
Connect
the ScopeMeter
se
tly,
t
e Series IIoscillosctest tool ande ap
un s lu s
ty ou l.
the
ali
le
or view
0
driv
m Pa a F rie
ction Voge cut
?M
ris
e 19 portab
rk
ng
of funevery
result: the
start
of
Ch
wo mm
s
its
Fluuk
nce
lievi
er.
co
s his
nt,
o ing ith Se
t ou
be g.
theroeM
no aletds
las uipme gel ha for the pical
is
measurement
in
c
g
o
c
ery
ch pti eth lse
eing tand ing ev test eq ies, Vorunning as tro90 F
usin Scynop
le us w 0
u
rid
O
Se ders
t
S us t m p pe
n wr ctronic chnolog ms in Flo nstop
jus
ca
o
s
ste
U
un
s
te nt ing 19
ts
sy mers
a no te IT sc rm
ly no d tha mens le
AC
ing ns If anyonece of eleilding Te
ing
ch ro rd rd illo o ils
g e st er
g ro
Bu ing HV ial custoseem els. An at Sie
su nch da da osc perf fa
Test
pin
a pie ns
tio
n
ns
ep
lev
by
n
ee
of
n
s
erc
i
y,
me
y
y
t
m e
ke
d
dit
Sie
m S sta sta ble to 100
hnicia re sw icienc d
Func e
At for him commmarke humi
tec
st ip t e
a ed to
ste the e e
ge service
s It frequently
is
a mo and
t
y eff ss, an er
by
are%automatically
detected
that
ouhappens
ich d 95
sy d quir t th port us p
ed plays energ
s lar wh
Ca dyengineers
n
u
adjusted,
followed g
by displayhave
a lotan
of
acceice tow
s fac ich
Te qu ask eM
panyto spend
on a re ins II be g
er,
s
ge
off
whsignalsu
n
a s n
rized orratio
ath measuring
Stu time adjusting
ing the
inrin
the correct
their
ati e a
e
p
we peraturechallen ies, s: en autho
ic rop ric ag rie ca tori
respect un
to the horizontal
device such as a portable
oscil- logwith es
ilding
un Eu me d Se at f s
m co
the
no
tem
cc
st
bu
m in
and vertical
loscope for an optimal
il ch rs su
ain axis.
e of setting.
A ste 0 th o
l
ery At least 1.5
aTe
e
onspent
h te r 19 n ble
ing
/f
om )
me rt tto
4ag
periodsev
of the signal are
Valuable time is
completing
ne o
S
e
ction d for rs.
of tim
Buildsscusto po ee
l c DH ort re te tio pa
an tw
th
p

ati

Application Note

ex
un
ote measured
before the pattern is
this set up, and ideally,
could
a thispr
N a e nc a
me
h
ita (S
pits
slice Vogel, to
n shar-bero
sto
c
in als eM fu
-c g ks een ial the shown.
be done automatically.
ort,ca ad
le
ein
s
ga
m cu
dig hy )
is
il
yre yecanit by
le sin s
or
th comf weof
orin rtant, say n be abms by
s rc ET ign op a t
fet
With the introduction
spthe
ip u ma betwcoax atch sym ial e
Stprovides
eto ef Connect and View
g s firewsa
icia
the
ay ra N l s Sc ss/f en
d
ble
a II,
at av
reliable and repeatin late 190
ult ng t ed a m ax th k. new ScopeMeter
impo techn D pro from A
ie Series
pl w a stable,
to ste
ad Hie (SO ica ke pa um
r
n, itrevamped
Its any
M sti ren us and e to 120 co ut of mas IIFluke has
VF
m a
se: en
fo e-display
intru
the
orm
p ukeVenits
icia
of virtually
unique
tr
tr lu
te g
ow al
eable
om
Ed m
that terize wavef premi g wh
m
te iffe n is nel lin e 75 tp ific ries feature,
cr hn
en disment
N igit ork lec e F ard ins .
at tec
ul
rac and
motor drive
Connect
or View.
s frincluding
om itin HV
ou
te h Fl efand
d est
lu
m st
plACsignal,
r
d
on th
cha ing aH ve. Hisre tellin view
beized
sthow
m whsignals,
D etw e e Th nd he sis
ed difit know
invfo

tur g dri
ba pa si of a d ec Se si teScope users
.
touchan m erg
n control
or an
cu by
mo
W wav
tr
cap
,
g, ter without
A tch is nce e to t an s sp 190 can /fail e
N Th ks. sta . T aly
ef aaton
l. ,ceeste en
gel
ca ing
dinSD
a dbe.
is ch
veform tsite changes
in Me Signal
button.
VoceWrong
triggering
a dcan
g av
a sts an
return
pa ansm da l lin pu it er es ss ficult
rmSco
th
ard
offen are
n
isD mu a wa tic volhas a
d
uspee large lete Exbe
com
/s
w instantly
as
fold m
re stginthe
nal ted in
k
. II
recognized
and
settings
showan
unstable
and
, sta nal
tr pe ca e in has et op pa ofsettings
ub
Mb sig
ea
s
nd igi- e an tal
g
he
on
m ers e te er
g
fe
2 75
sin
n nd
te viha
cr results.
ut rieks ol er wrong
orat for,
d tro
sen a single e sig may loojust
im etri Th ch eM sc m a tpSe
in recuslFlukes
.csvadjusted
once
again,
apre
stable
ef t or an
ed et
sta rd orvoic digi mdrives
off es rth
0 massometimes
us A /fin
ai his
in
statTo
ld
m e. ea op cillo or19ou
sa inol. Ou
g. Th that
encyis rep
display.
This
all air
done autounique
Connect and View
th r fu
To wav
rf d rt Te
than readin value but cou n or
monitfrequ
ls:
03 anda for er reco T) M l- lin lun e Sc too
ss by stiew
os pe
el
isol opeMake
en
ce
e
,
we
ete
Te
d
ov
g
ta
lev
pa
fo
.7
an
le
le
matically,
but
manual
overruling
recognizes
signal
patterns,
and
ba Thing ly eM
age
U CIT PC gi
ed eV ere
st ed
nce
tortio ntary
th
t ffer d Sc s m
in r,
iab nent- differen
G
un and
pe an
at ukwh
g
al
s- ak sets
ve
pu di g an e automatically
Scop
rtabl us
po possible.
is still
overcorrect
sha at a glave a dis mome be
e is a uc sion IT ly C the di
B
ol
asur
in ot varcom
the
paIfrtmanual
m eo lowup
Fl itsho
a
po ne
to ACpoing
air I the
neo in ith in Fluk
Th 03 introdsmis is anmer with ce toing to of Me
in an
right ily ha or
rt to a host
is/s needed,
ScopeMeter
triggering,
attenuator
know
al t andedtime
l, stHV
tsild of Mor
Ds), ruling
mean
ta the n w float ege
g Ch
h
Mb rep
Bu
es ithou e
en risksettings.
2 00
bill. recently
.
as eas edge, too shom, or s, would
190 $2
Series
from
on (VF
the often
th II te
G.7ally tran . It (for ed -voi rd idth ltin 2. auto12 airwill switch
ug
at lu eris Vo
nsmbase
gs ob wSwitching
gh
a
ost
can een a rep
t th oscilloscope
e
we
nario
n ta orks on ciat og acco dw su ro T1
ba Ch
Th of riesmesure ScopeMeter
matic0 to 1/2 automatic,
which isrou ke alm r probleomalie th just
th ndin pr tsportable
ou tial
betw 00,00 cause very sceuses his
n ), re . Th a
da etw dati so nal n
tto
he
ator: forts Sie
wi
l an
spi
en
ithge
Eit
nal.
be
pe
visible
on
the
display.
correct
signal
patterns
nce men
t
,
na
$1
oudisplay
lta
ble
n.
n en as . A rsio a ba m .703 s in Oper nicianinpu 0 Se mea hou gr
er
a
w ff
nd
tha Vogel illosco , see er sig
h
ha the sig to
da red vo
l ted 1 gives
Figure
an
couple
of seconds, firsthatcne
m ats rd nve es 0 pp r G sult of Tech
di
19 ese wit d only
Ds,
oscexample
pe takes
an andator
logies
ics
blems of of othr y istinguis g of
su
me m a
Pa en
ble of pro
al
th anda co ir 10 fo re E1
im nt
din
th ble ante rre
ge VF rta
thelar
different
types
waveforms
is exactly
what an
Pa
eathisefac
rist chno
docum
h and
r aind ric rea allowsand fro ves
/s
po
mwelinr tern
and e.
st ta requ ( it is d
be
teTe e
tanceps, by
si ts:
On
w Cu
ig operator
ter
Mb
which
can deacidetected
e wa
ac ar on
2 0
i b me scope on,
gat
da M /s c un g th an
, ctpothe exwants.
un e hsisre
sha
12
peMe er&cap
ar es ti a inemen
Connect
View.
If srequired
the/ l nu The ormatircessinputs of d,
on a basiPC 4 kb si in b/s
Sco
g r an regarding
th di Settings
aly
ng migh
ch rfac da r nur
inf sou
AC/DC
m
uncov for
out
r firibest
ean
6 e ba plex M s.
r iscano ,
settings
be
al te en s fo as
ord coupling
m an for adind foamplitude,
tocriteria
of
ow
and voltag parirec
-throunsisto itch
e
Glitch
nsisto edby
th ulti 44 b/ tric k in mm itMe
lo ee timebase,
sh vefor
optimized
switchingswon
mberdetect
tra
onge
. c onedor nu
e.
inputs t and ke com e so
m 1.5 8 M elec or co lim ewa
n blerse, a tra -fast ba
n obtriggering,
e ck ansed, Figure
ph
eveofcou
tag
all
the following
le an

ing options:
2 shows
the
different
tor
k
of .04 e etw in re gnal al ar
on the
pr
r, ma
currentte
Te ch
ues and clo to
d vol r fac
itch
lightn
Ds,
Ex
l
2 Th e n d si gn
Automatic
trigger
an
Of
etc.
settings.
ma
a
we
sw
t
s,
VF
rt
t
f en
ren
a po
tha
th be e si
cally s. It een. op mes sta happen
for of cur rive
say tw w eti
t
of scri 3. Th b/s
s
de
30
k he
be w som en tha weird
N
son I can
or
de .70 8 M .
t.
tw
w
ISD
forth it can
1
d
ing
. Wh
circui
G .04
that
ne
the
and@ down start dole, at loa
30
2 gure
for
ak
ll
DN
Fi
IS
r ybre tors wi examp ly see and
2.
re
r a mo ngs. Forll actual back which
gu
thi
Fi
we bangingt sure
ib
y
L
ar
stagemotor is no
br
l
i
it
l
if
/
a
the as
m
n.
it
forth to tur
.co
ig
ke
way
D
flu

re
gu
Fi

1.

03
G7

- E1

e
at
pl
m
te

F
th

ro

Figure 1.

lu

Fr

om

th

Flu

ke

Di

git

al

Lib

ra

ry

ww

w.

If youve used other scopes, you know how tricky


triggering can be. If settings are incorrect, results
can be unstable or incorrect. Connect-andView automatically sets up correct triggering
by recognizing signal patterns. Without touching
a button, you get a stable, reliable and repeatable
display of virtually any signal including motor
drive and control signals. Its especially fast and
convenient when youre measuring a number of
test points in rapid succession.

Connect-and-View captures even the


most complex motor drive signals.

From the Fluke Digital Library @ www.fluke.com/library

A range of application notes is available.


See the Fluke website.

Included Accessories

Fluke 190 Series II 4-channel instruments include a set


of four probes, hanging strap, handstrap, USB cable with
mini-B connector, double capacity Li-ion battery BP291,
battery charger/power adapter BC190, a FlukeView demo
package and users manuals on CD-ROM. The /S-versions
also include the C290 hard-shell carrying case and the
FlukeView software package. The 2-channel models come
with two probes plus a set of TL175 test leads and a single
capacity battery BP290. The 190-502 also includes two
pieces TRM50 coaxial feedthrough terminator.
The SCC290 kit includes: C290 hardshell carrying case and
FlukeView for Windows software (full version).

Built-in digital multimeter (2 channel models)


190 Series II models with isolated dual input
scope and dedicated digital multimeter.
Conveniently switch from waveform analysis
to precise multimeter measurements using
the built in 5000 count digital multimeter.
Measurement functions include Vdc, Vac,
Vac+dc, resistance, continuity and diode test.
Measure current and temperature using suitable
shunt, probe or adapter with wide range of
scaling factors.

The built in multimeter provides


convenient precision measurements.

Ordering Information

Fluke-190-502/S Color ScopeMeter (500 MHz,


2 channel), with SCC290-kit
Fluke-190-204/S Color ScopeMeter (200 MHz,
4 channel), with SCC290-kit
Fluke-190-204
Color ScopeMeter (200 MHz, 4 channel)
Fluke-190-202/S Color ScopeMeter (200 MHz,
2 channel), with SCC290-kit
Fluke-190-202
Color ScopeMeter (200 MHz, 2 channel)
Fluke-190-104/S Color ScopeMeter (100 MHz,
4 channel), with SCC290-kit
Fluke-190-104
Color ScopeMeter (100 MHz, 4 channel)
Fluke-190-062/S Color ScopeMeter (60 MHz,
2 channel), with SCC290-kit
Fluke-190-062
Color ScopeMeter (60 MHz, 2 channel)
AS400
Probe Accessory Extension set for
VPS400 Series probes
BP291
Double capacity Li-Ion battery
(4800 mAh) pack for 190C Series II
BP290
Single capacity Li-ion battery
(2400 mAh) pack for 190-series II
C195
Soft padded carrying case for
ScopeMeter and accessories
C290
Protective Carrying Case for Fluke
190-series II
EBC290
External Battery Charger for charging
BP290 or BC291 outside the instrument
HH290
Hanging Hook
RS400
Probe Accessory Replacement set
for VPS400 series probes
RS500
Probe Accessory Replacement set
for VPS510 series probes
SCC290
Software and Case kit for Fluke 190
Series 190 Series II. Includes SW90W
and C290.
SW90W
FlukeView ScopeMeter Software for
Windows (full version)
TRM50
Coaxial 50 feedthrough terminator
VPS410-x
Probe-set, 10:1, 1000V CAT III / 600V
CAT IV (colors: blue, green, red, grey)
VPS420-R
Probe-set, bicolor (r/b), 100:1, 150 MHz,
1000V CAT III / 600V CAT IV, working
voltage (voltage between probe tip and
reference lead): 2000V CAT III / 1200V
CAT IV.
VPS510-x
Wide bandwidth probeset, 500 MHz,
10:1, 600V CAT III

Automatic capture and replay op 100 screens


Scope users know how frustrating it is to see a onetime anomaly flash by, never to be seen again. Not
with the ScopeMeter 190-series! Now you can look
back in time with the touch of a button. In normal
use, the instrument continuously memorizes the
most recent 100 screens. At any moment in time, you
can freeze these latest screens and scroll through
them picture-by-picture or replay them as a live
animation. Cursors and zoom can be used for further analysis. You can even use
the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100
screens with individual time stamps can be stored for later recall or download to a PC.

See dynamic signal behavior instantly


The digital Persistence mode helps to find anomalies and to analyze complex
dynamic signals by showing the waveforms amplitude distribution over time using
multiple intensity levels and user selectable decay time its as if youre looking at
the display of an analog, real time oscilloscope! A fast display update rate reveals
signal changes instantaneously, useful for instance when making adjustments to a
system under test.

Recommended Accessories

www.chorus.ro
SW90W

SCC290

VPS420-R

EBC290

AS400

83

ScopeMeter 120 Series


Three-in-one simplicity

Fluke 125

Fluke 124

The compact ScopeMeter 120 Series


is the rugged solution for industrial
troubleshooting and installation
applications. Its a truly integrated test
tool, with oscilloscope, multimeter and
paperless recorder in one affordable,
easy-to-use instrument. Find answers to
problems in machinery, instrumentation,
control and power systems quickly and
easily.

unique Connect-and-View recognizes


signal patterns, and automatically
sets up correct triggering. It provides a
stable, reliable and repeatable display
of virtually any signal - including
motordrive and control signals - without
touching a button. Signal changes
are instantly recognized and settings
adjusted for - once again - a stable
display.

Dual-input 40 MHz or 20 MHz digital


oscilloscope
Two 5,000 counts true-RMS digital
multimeters
A dual-input TrendPlot recorder
Bus Health Test for industrial bus
systems (Fluke 125)
Connect-and-View trigger simplicity
for hands-off operation
Power Measurements and Harmonics
measurement (Fluke 125)
Shielded test leads for oscilloscope,
resistance and continuity
measurements
Up to 7 hours battery operation
600 V CAT III safety certified
Optically isolated interface for PC and
Printer connection (optional)
Rugged, compact case

Use TrendPlot to help find


intermittents fast

Connect-and-View triggering for


an instant, stable display

Fluke 123

Scope users know how difficult triggering


can be. Wrong settings show unstable
and sometimes wrong results. Flukes

The toughest faults to find are those


that happen only once in a while:
intermittents. They can be caused by
bad connections, dust, dirt, corrosion
or simply broken wiring or connectors.
You may not be around to see it your
Fluke ScopeMeter will. In this paperless
recorder mode, you can plot the
minimum and maximum peak values
and average over time up to 22 days
(Fluke 190 Series) or 16 days (Fluke 120
Series).

Bus Health mode (Fluke 125)


Bus Health mode gives a clear Good/
Bad indication for the electrical signals
on industrial buses and networks, such
as CAN-bus, Profi-bus, RS-232 and many
more. The Fluke 125 validates the quality
of the electrical signals as soon as any
electrical signals are passed along the
network.

True RMS

Included Accessories
PM 8907 line adapter/charger, STL120-III
shielded test leads set (1 red, 1 grey) including
hook clips, BB120 shielded BNC adapter,
BP120MH NiMH battery pack, VPS40-III wide
bandwidth Voltage Probe (Fluke 124/125),
TL175 Safe-guard testlead, i400s current
clamp (Fluke 125), Getting Started booklet,
users manual (cd-rom)

Ordering Information

84

Fluke 123
Industrial ScopeMeter (20MHz)
Fluke 123/S Industrial ScopeMeter (20MHz)
+ SCC120 kit
Fluke 124
Industrial ScopeMeter (40MHz)
Fluke 124/S Industrial ScopeMeter (40MHz)
+ SCC120 kit
Fluke 125
Industrial ScopeMeter (40 MHz)
Fluke 125/S Industrial ScopeMeter (40 MHz) +
SCC120 kit
SCC120
FlukeView Software + OC4USB
Cable + Carrying Case
OC4USB
USB Interface Cable
PM9080
RS-232 Interface Cable
DP120
Differential Voltage Probe
ITP120
Isolated Trigger Probe
SW90W
FlukeView Software
BHT190
Set of 3 break-out adapters
(Fluke 125)

Connect-and-View captures even the most


complex motor drive signals.

Bus Health mode allows for an analysis of the


signal quality on an industrial network.

See page 85 for specifications.

Recommended Accessories

www.chorus.ro
SCC120

C125
See page 124

DP120
See page 86

OC4USB
See page 86

SCC128
See page 125

ScopeMeterTest Tools
Fluke 225C/S Industrial Networks
and Bus Health Test

Built on the Fluke 190C-series, the 225C/S makes Bus Health


Test analysis on the electrical signals on an industrial bus
or network, giving a clear Good, Weak or Bad validation
of the relevant parameters, presented next to the actual
measurement value. The Fluke 225C/S can make the signal
quality validation as soon as electrical signals are passed
along the network, without looking at the data content. It finds
errors like improper cable connections, bad contacts, incorrect
grounding and missing or superfluous terminators.

Included Accessories
BHT190

Set of three break-out adapters for


industrial networks
BC190
Mains adapter/Battery charger
BP190
NiMH battery pack (installed)
VPS210 Voltage probe sets (1 red, 1 grey)
TL175
SafeGuard(r) Testlead set
C190
Hard shell protective carrying case
OC4USB Optically insulated USB interface
cable for PC connectivity
SW90W FlukeView software package
(full version)

Ordering Information
225C/S

Color ScopeMeter (200 MHz,


2.5 GS/s) with Bus Health Test
capabilities and SCC-kit.

Typical status overview of a bushealth measurement.

General ScopeMeter
Specifications
Model:

190-502

190-204

190-202

190-104

190-102

190-062

225C/S

125

124

123

Oscilloscope Specifications
Bandwidth

500 MHz

200 MHz

100 MHz

60 MHz

200 MHz

5 GS/s

2.5 GS/s

1.25 GS/s

625 MS/s

2.5 GS/s

Max. timebase speed

1 ns/div.

2 ns/div.

10 ns/div.

5 ns/div.

Inputs and digitizers

2 + Ext.Tr.

2 + Ext.Tr.

2 + Ext.Tr.

2 (+ Ext.Trig. Optional)

600 V
CAT III

Max. real time sample rate


Input sensitivity

Independently floating isolated inputs

Dedicated test capabilities

5 mV/div.

4 ns/div.

2 + Ext.Tr.

600 V
CAT III

2 + Ext.Tr.

1000 V CAT III,


600 V CAT IV
10 000 samples per trace
30 000 min/max pairs
8 ns peak detect at full timebase range

yes

yes

V/Hz ratio

V/Hz ratio

BP291

BP291

BP290

20 MHz

25 MS/s

2 mV/div.

Max.record length
. In Scope mode
. In ScopeRecord mode
Glitch capture
True RMS multimeter built-in (5000 counts)

40 MHz

3000
27500
50 ns

10 ns/div.

512 min/max pairs per input


40 ns

yes
V/Hz ratio

20 ns/div.

dual 5000 counts DMM


Bus health test

General Specifications
Mains adapter/battery charger incl. (type)
Battery installed

BC 190
BP291

PM8907
BP290

BP290

www.chorus.ro
Size

Weight

Safety certified

265 x 190 x70 mm

2.1 kg

2.2 kg

2.1 kg

2.2 kg

1000 V CAT III / 600 V CAT IV

2.1 kg

BP190

BP120MH

**

232 x 115 x 50 mm

2 kg

1.2 kg
600 V CAT III

85

ScopeMeter Accessories

VPS410-X

VPS420-R

ScopeMeter series

VPS510-x

STL120-III

190-series II

Description

VPS40-III

120-series

VPS410-x

VPS420-R

VPS510-x

STL120-III

VPS40-III

DP120

Voltage probe

Wide bandwidth
voltage probe
red, grey, blue, green

Shielded Test leads

Voltage probe

red + grey (1 set)

red, grey, blue, green

High working voltage


probe*
bicolor (red & black)

black

Differential Voltage
Probe
red + grey (1 set)

Attenuation

10:1

100:1

10:1

1:1

10:1

200:1 / 20:1

Bandwidth

300 MHz

150 MHz

500 MHz

12.5 MHz

40 MHz

20 MHz

1.2 m

1.2 m

1.2 m

1.2 m

1.2 m

1.5 m (2x)

Colors available

Length
Safety Rating CAT II

--

--

--

1000 V

1000 V

1000 V

Safety Rating CAT III

1000 V

1000 V*

300 V

600 V

600 V

600 V

Safety Rating CAT IV

600 V

600 V*

--

--

--

--

* High Working Voltage Probe is specified for working voltages (between probe tip and reference lead) up to 2000V in CAT III or 1200V in CAT IV environments. Reference lead
voltage (between reference lead and earth ground): 1000V in CAT III, 600V in CAT IV. These specification applies only when used with Fluke 190-series II Test Tool.

PM9081

PM9091/9092

PM9091
Description

PM9092

Safety designed 50 BNC Cable set


(1 red, 1 black, 1 grey)
1.5 m each
0.5 m each

Length
Safety Rating CAT III

RS400

RS400
AS400
PM9080
OC4USB
BP120MH
BP290
BP291
EBC290
TRM50
RS500
C437-II
RF-AM90

86

PM9082

300 V

600 V

AS400

PM9093

DP120

PM9081

PM9082

PM9093

Dual banana plug


(m) to female BNC
--

Dual banana jack


(f) to BNC plug (m)
--

BNC (m) to dual


BNC (f) T-piece
--

600 V

600 V

10:1

BP291

OC4USB

Probe Accessory Replacement set for VPS200 and VPS400 series probes
Accessory Extension set for VPS200 and VPS400 series probes
RS232 interface cable for 120-series
Optocoupler to USB interface cable for 120 series
Ni-MH battery pack for Fluke 120-series and Fluke 43B
Single capacity Li-ion battery pack for 190-series II
Double capacity Li-ion battery pack for 190-series II
External battery charger for BP290 and BP291
Coaxial 50 feedthrough terminator
Probe Accessory Replacement set for VPS510 series probes
Hard shell protective carrying case with rollers for 190-II and 430-II
RF Detector and Demodulation probe

www.chorus.ro

EBC290

Power Quality Tools and Power


Analyzers
We offer an extensive range of power quality test tools for
troubleshooting, predictive maintenance and long-term recording in
industrial and utility applications. For the development and test of
electrical equipment, our high-precision power analyzers enable easy
and reliable use in the field or as a bench unit in test laboratories.
Additionally, the Fluke-patented energy loss algorithm, Unified Power
Measurement, measures and quantifies energy losses due to harmonics
and unbalance issues, allowing the user to pinpoint the origin of energy
waste within a system.

www.chorus.ro

87

Power quality tools help pinpoint problems fast

88

Detailed RMS trending shows how connected loads


behave.

RMS voltage
RMS Current
Energy studies
Measure V, I, kW, Cos/DPF, kWhr
Measure MIN/MAX and AVG values
10 day logging
Energy aggregation
Utility meter pulse input
Energy Loss (Eff. kW, Reactive kVAR, Unbalance kVAR,
Distortion kVAR, Neutral kVAR)
Energy loss calculator
Basic harmonics study
THD measurement (V & I)
Harmonics 1 to 25 for V & I
Tabular values
Neutral current measurement
Crest factor
Advanced harmonics study
Full harmonic spectrum
Power harmonics
Harmonics 1 to 50 and dc
k-factor
%Fundamental and %RMS
Basic Industrial PQ Troubleshooting
Oscilloscope function
Voltage dips and swells
Phasor diagram
Trend recording
Inrush current
Advanced industrial PQ troubleshooting
Comprehensive logging capability
Transient capture
Flicker
EN50160 analysis
Complex System interaction event capture (manual
threshold setting)
Random/variable system event capture (Adaptive
threshold setting)
400 Hz
Utility PQ benchmarking
Phase sequence components
Interharmonics
Mains signaling
IEC61000-4-30 Class A
Software
Power Log
PQ Log
Power Analyze
PQ Analyze
FlukeView Forms
FSD card (max 32 GB)
O(only 437-II)

O
O
O
O

O
O
O
O
O

O
8 GB

O
O

O
O

O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

430 II
O
O

To make use of the power data you collect, you need


software that can help analyze your findings and share
them with equipment providers and plant management.

O
O

O
O
O
O
O

O
O
O
O

O
O

O
O

O
O
O
O

43B
O
O

O
O
O
O

Single phase
345
O
O

O
O
O
O

O
O

O
O

VR1710
O

Before you install sensitive loads, make sure you


understand the existing quality of power delivered by
your utility. Comparing benchmarks over time can help
pinpoint potential areas of concern.

Complex installations often require a deeper dive into


measurement data. Multiple loads may be interacting
randomly to cause a single problem.

When troubleshooting in the field, graphical data


enables you to trace the source of the problem at hand.

If distorting loads are causing problems in your


installation, you need comprehensive data to intentify
the source and create a solution.

Discover the source of distortion in your installation, so


that you can filter those loads or move them to separate
circuits.

Get detailed power and energy consumption


profiles during energy audits and pinpoint savings
opportunities.

Application use

www.chorus.ro

Basic measurements

O
O

O
O
O
O

O
O
O
O

1735
O
O

O
O

O
O

DC)
 O (no
(not 1743)

O
O(not 1743)
O
O
O

O
O
O
O

Three phase
1740
O
O

8 GB

O
O
O

O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O

1750
O
O

O
O
O
O

O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O
O

O
O
O
O

1760
O
O

Power Quality Selection Guide

345
Power Quality Clamp Meter
The ideal troubleshooting tool for modern
electrical loads
The Fluke 345 measures a wide range of
electrical parameters for troubleshooting
power disturbances in single- and
three-phase electrical loads. With a
bright color display to see waveforms
and trends, a low-pass filter to remove
high frequency noise, and a high EMC
immunity design, the Fluke 345 is ideal
for measurements on switching loads
such as variable speed drives, electronic
lighting and UPS systems.

High safety rating: 600V CAT IV / 1000V


CAT III rated for use at the service
entrance
ac/dc current measurements: Clampon measurement of ac peak and dc
current up to 2000 A without breaking
the circuit
Harmonic analysis: Analyze, display
and log harmonics up to the 30th
harmonic (40th harmonic for 15 Hz to
22 Hz)
Verify batteries: Direct measurement
of dc ripple (%) for battery and dc
systems

Specifications
(Check the Fluke web for detailed specifications)

Fluke 345
Current measurement
DC, DC rms, AC rms

All measurements DC and 15 Hz to 1 kHz.


Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms
measurement (AC + DC).
0 2000 A dc or 1400 AC rms
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Measuring range
Harmonics
Voltage measurement
DC, DC rms, AC rms

All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a
true-rms measurement (AC + DC).
0 825 V DC or AC rms
All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
to 65 Hz; Vacrms > 1V

Measuring range
Harmonics
Watts measurement (single- and three-phase)

Measuring range

View waveforms for equipment


checking and setup

VA measurement (single- and three-phase)

Measuring range

DC, DC rms, AC rms


0 1650 kW DC or 1200 kW ac
DC, DC rms, AC rms
0 -1650 kVA DC or 1200 kVA ac

VAR measurement (single- and three-phase)

Measuring range

0 1250 kVAR

Power factor (single- and three-phase)

Measuring range

0.3 cap1.0 0.3 ind (72.5 cap0 72.5 ind)

Displacement power factor

Measuring range

0.3 cap 1.0 0.3 ind (72.5 cap ... 0 ... 72.5 ind)

Kilowatt Hour (kWHr)

Measuring range

40,000 kWHr

Scope function

Time base
Current management:
Ranges
Voltage measurement:
Ranges

2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div


10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A
4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V
All measurements dc and 15 Hz to 1 kHz
40, 400 and 2000 A
Up to 50 screen shots and over 150,000 individual measurement values

Inrush current function

Ranges

Log parameters over time


to track down intermittent faults

Memory

Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6


x 6 Battery
Battery life (typical): >10 hours (backlight on full);
>12 hours (backlight reduced)
Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III
(maximum input phase-phase 825V rms) double or
reinforced insulation, pollution degree 2
Protection: IP40; EN60529
Operating temperature: 0 C to 50 C

Display: Color transmissive LCD 320 x 240 pixels


(70 mm diagonal) with 2 level backlight
Digital output: USB interface to a PC
Size (HxWxD): 300 mm x 98 mm x 52 mm
Jaw opening: 60 mm
Jaw capacity: 58 mm diameter
Weight (including batteries): 0.82 kg
Two Year Warranty

Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International ac adapter / battery eliminator,
Printed English User manual, Multi-language
manual on CD

Recommended Accessories

Ordering Information

www.chorus.ro
Fluke 345

Power Quality Clamp Meter

TLK291
See page 123

TP220-1
See page 123

AC220
See page 124

TP1-1
See page 123

C550
See page 130

89

43B Single-phase Power


Quality Analyzer
The perfect tool for tracking down
single-phase power-related problems
The Fluke 43B is the choice for
diagnosing and troubleshooting power
quality and general equipment failures.
Ease to use thanks to menu selection of
the power modes, it combines the

capabilities of a power quality analyzer, a


20 MHz oscilloscope, a multimeter and a
data recorder in a single instrument.

Voltage, current, and


power harmonics
Up to 51st harmonic
Total harmonic distortion
(THD)
Phase angle of individual
harmonics

Continuously measure
volts and amps on a
cycle-by-cycle basis for up
to 16 days
Use cursors to read time
and date of sags and
swells

Watts, power factor,


COS , VA and VAR
Voltage and current
waveforms

Connect-and-View
scope for quick waveform
display
View voltage and current
channels simultaneously

Fluke 43B

Specifications
(Check the Fluke web for detailed specifications)
Menu items
Volts/Amps/Hz

On all inputs
Power
Harmonics

True RMS
Sags & Swells
Transient Capture
Inrush Current
Ohms/Continuity/
Capacitance
Temperature
(with accessory)
Scope

Included Accessories
TL224 test lead set, AC220 alligator clip set,
TP4 test probe set, BP120MH rechargeable
battery pack, BB120 shielded BNC adapter,
PM8907 line adapter/charger, i400s AC current
clamp, AB200 alligator clip set,
TP1-1 test probe set, C120 hand carrying case,
OC4USB interface cable, SW43W FlukeView
software, VPS 40 voltage probe, Fluke 61 IR
thermometer, user and application manual.

Screen saves
Recording

Measurements
Volts
Amps
Mains frequency
CF Crest Factor
Watts, VAR, VA
PF, DPF, COS
Volts
Amps
Watts
K-factor
Voltage and Current
40 ns pulse width
Up to 40 transients
1 sec. to 5 min selectable
Ohms
Capacitance
C
F
DC, AC, AC+DC, peak,
peak-peak, Hz, duty cycle,
phase, pulse width,
crest factor
All functions
V/A/Hz, Power, Harmonics,
/Cap, Temperature, Scope

90

Accuracy
(1%+10)
(1%+10)
(0.5%+2)
(5%+1)
(4%+4)
0.04
0.03
(3%+2) to (15%+5)
(3%+8) to (15%+5)
(5%+2) to (30%+5)
10%
(2%+10)
5% of full scale
5% of full scale
(0.6%+5)
(2%+10)
(0.5%+5)
25 MS/sec
20 MHz
15 kHz
Select any two parameters
display mode in each

Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)
Shock & Vibration: Mil 28800E, Type 3, Class III, Style B.
Operating temperature: 0C to 50C; Case: IP51 (dust, drip, waterproof)
Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg
Three Years Warranty

Ordening information
Fluke 43B

Ranges
5.000 V - 1250 V
50.00A - 50.00 kA
40.0 - 70.0 Hz
1,0 10,0
250 W - 1.56 GW
0.25 W-0.9
0.90-1.00
1 st to 51 st harmonic
1 st to 51 st
1 st to 51 st
1.0 to 30.0
4 min-16 days selectable
Select 20/50/100/200%
above or below line voltage
1 A to 1000 A
500.0 to 30.00 M
50.00 nF to 500.0 F
-100.0C to 400.0C
-200.0F to 800.0F
Sampling rate:
Bandwidth:
Voltage BW (Channel 1)
Current BW (Channel 2)
20 screens
4 min - 16 days selectable

Power Quality Analyzer


(single-phase)

www.chorus.ro

Recommended Accessories

i2000flex
See page 126

i1000s
See page 126

80TK
See page 128

VR1710 Single-Phase Voltage


Quality Recorder
Easy-to-use solution for detecting and
recording voltage quality problems

Fluke VR1710

The Fluke VR1710 is a single-phase, plugin voltage quality recorder that provides
fast and easy recording of voltage trends,
dropouts, harmonics and general power
quality including dips and surges to help
maintenance and facilities management
personnel easily pinpoint the root cause
of voltage problems. Voltage quality
parameters including RMS average,
transients, flicker, and harmonics up to
the 32nd are recorded using a userselected average period from
1 second to 20 minutes.

Clear graphical summary of data and


quick overview of key power quality
parameters
Get the complete picture with Min, Max,
Average RMS values (1/4 cycle) with
time stamps
See the detailed with actual transient
display (> 100 s) with time stamp
Comprehensive analysis of Individual
harmonic and THD values with trends

Applications
Voltage recording Monitors and
records supply voltage; measures RMS
average, minimum and maximum
values, and checks whether the socket
outlet is providing voltage within
tolerance.
Distortion measurement Measure
frequency and harmonics; check
whether the distorting loads (UPS
systems, drives, etc.) are affecting your
other equipment.

Flicker measurement Quantify the


affects of switching loads on lighting
systems.
Voltage transients Capture those
intermittent, momentary events that
may be affecting your equipment; the
full waveform is captured with date,
timestamp, and duration.

Fluke VR1710 and included accessories

PowerLog Setup Simple set up of


internal clock, logging periods, and
intervals with default values for
quick results.
PowerLog View Data presentation
showing RMS voltage and harmonic
trends, actual transients, summary
information and statistics in
accordance with EN50160.

Actual transient display


(> 100 s) with time stamp
Quickly identify issues with included
graphical software.

Statistical analysis of voltage event


reduces analysis time by tracking
event quantities and magnitudes.

Specifications
(Check the Fluke web for detailed specifications)

Includes PowerLog software

Included Accessories
Plug-in Fluke VR1710, USB cable, PowerLog
software CD, universal power cord adapters.

Operating voltage
Min/Max/Avg RMS value
Number of events
Dips/Interruptions
Time resolution
Voltage resolution)
Over-voltages
Frequency
Harmonics measurement
Flicker measurement
Number of recording channels
Recording time
Transients
Frequency range
Safety category rating

www.chorus.ro

70 V to 300 V
Resolution 0.125 V
175,000
Yes
5 ms
0.125 V
Yes
Yes
EN 61000-4-7 (up to 32nd)
EN 61000-4-15
1 Phase to Neutral
2 Phase/Neutral to Ground
1 day to 339 days depending on average time from 1 second to 20 minutes
Yes (> 100s)
50 Hz 1 Hz and 60 Hz 1 Hz
CAT II 300 V

Ordering Information
Fluke VR1710

Voltage Quality Recorder

Display: LED
Size (HxWxD): 23 x 19.75 x 22.2 cm

Weight: 0.8 kg
Two years warranty

91

430 Series II Three-Phase Power


Quality and Energy Analyzers
New

More detailed power quality analysis capability,


and a Fluke-patented energy monetization function
The new Fluke 434, 435 and 437 Series II models
help locate, predict, prevent, and troubleshoot
power quality problems in three-phase and singlephase power distribution systems. Additionally,
the Fluke-patented energy loss algorithm, Unified
Power Measurement, measures and quantifies
energy losses due to harmonics and unbalance
issues, allowing the user to pinpoint the origin of
energy waste within a system.

Fluke 437-II

Fluke 435-II

Fluke 434-II

Compliant
Fluke
435 II / 437 II

True RMS

On all inputs

www.chorus.ro
Phasor diagram.

92

Energy loss calculator: Classic active and reactive


power measurements, unbalance and harmonic
power, are quantified to pinpoint true system
energy losses in dollars.
Power inverter efficiency: Simultaneously
measure AC output power and DC input power
for power electronics systems using optional DC
clamp.
PowerWave data capture: 435 and 437 Series II
analyzers capture fast RMS data, show half-cycle
and waveforms to characterize electrical system
dynamics (generator start-ups, UPS switching
etc.).
Waveform capture: 435 and 437 Series II models
capture 100/120 cycles (50/60Hz) of each event
that is detected in all modes, without set-up.
Automatic Transient Mode: 435 and 437 Series II
analyzers capture 200 kHz waveform data on all
phases simultaneously up to 6 kV.
Fully Class-A compliant: 435 and 437 Series II
analyzer conduct tests according to the stringent
international IEC 61000-4-30 Class-A standard
with 435 and 437 Series II analyzers.
400 Hz measurement: 437 Series II analyzer
captures power quality measurements for avionic
and military power systems.
Troubleshoot real-time: Analyze the trends using
the cursors and zoom tools.
Highest safety rating in the industry: 600 V CAT IV/
1000 V CAT III rated for use at the service
entrance.
Automatic Trending: Every measurement is
always automatically recorded, without any
set-up.
System-Monitor: Ten power quality parameters
on one screen according to EN50160 power
quality standard
Logger function: Configure for any test condition
with memory for up to 600 parameters at user
defined intervals.

Track harmonics up to the 50th, and measure and record


THD in accordance with IEC61000-4-7 requirements.

Unified Power Measurement


Flukes patented Unified Power Measurement
system (UPM) provides the most comprehensive
view of power available, measuring:
Parameters of Classical Power (Steinmetz 1897)
and IEEE 1459-2000 Power
Detailed Loss Analysis
Unbalance Analysis
These UPM calculations are used to quantify in
dollars the cost of energy loss caused by power
quality issues.

Energy savings
The cost of power quality could only be
quantified in terms of downtime caused by lost
production and damage to electrical equipment.
The Unified Power Measurement (UPM) method
now goes beyond this to achieve energy savings
by discovering the energy waste caused by
power quality issues. Using the Unified Power
Measurement, Flukes Energy Loss Calculator will
determine how much money as facility is losing
due to waste energy.

Unbalance
UPM gives a more comprehensive breakdown of
the energy consumed in the plant. In addition
to measuring reactive power (caused by poor
power factor), UPM also measures the energy
waste caused by unbalance; the effect of unevenly
loading each phase in three-phase systems.

Harmonics
UPM also provides details of the energy wasted
in your facility due to the presence of harmonics.
The presence of harmonics in your facility can
lead to:
Overheating transformers and conductors
Nuisance tripping of circuit breakers
Early failures of electrical equipment

The System-Monitor overview gives instant insight into


whether the voltage, harmonics, flicker, frequency and
the number of dips and swells fall outside the set limits.
A detailed list is given of all events falling outside the
set limits.

430 Series II Three-Phase Power


Quality and Energy Analyzers
Energy Loss Calculator

Useful kilowatts (power) available


Kilowatts made unusable by harmonics
Kilowatts made unusable by unbalance issues
Total billable kilowatt hours wasted
Total cost of wasted kilowatt hours

Logging provides instantaneous analysis of user


selectable parameters.

Input characteristics
Voltage inputs
Number of inputs

4 (3 phase + neutral) dc-coupled

Maximum input voltage

1000 Vrms

Nominal voltage range

Selectable 1 V to 1000 V

Max. peak measurement voltage

6 kV (transient mode only)

Input impedance

4 M//5 pF

Bandwidth

> 10 kHz, up to 100 kHz for transient mode

Scaling

1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable

Current inputs

Fluke 437 II with all standard accessories.

Number of inputs

4 (3 phase + neutral) dc- or ac-coupled

Type

Clamp or current transformer with mV output or i430flex-TF

Range

0.5 Arms to 600 Arms with included i430flex-TF (with sensitivity 10x)
5 Arms to 6000 Arms with included i430flex-TF (with sensitivity 1x)
0.1 mV/A to 1 V/A and custom for use with optional ac or dc clamps

Input impedance

1 M

Bandwidth

> 10 kHz

Scaling

1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable

Measurement modes
Scope
Volts/amps/hertz

Vrms phase to phase, Vrms phase to neutral, Vpeak, V Crest Factor, Arms Apeak, A Crest Factor, Hz

Dips and swells

Vrms, Arms, Pinst with programmable threshold levels for event detection

Harmonics dc, 1 to 50, up to 9th harmonic


for 400 Hz

Harmonics Volts, THD, Harmonic Amps, K factor Amps, Harmonic Watts, THd Watts, K factor
Watts, Interharmonic Volts, Interharmonic Amps, Vrms, Arms (relative to fundamental or to
total rms)
Vrms, Arms, Wfull, Wfund., VAfull, VAfund., VAharmonics, VAunbalance, var, PF, DPF, CosQ,
Efficiency factor, Wforward, Wreverse
Wfund, VAharmonics, VAunbalance, var, A, Loss Active, Loss Reactive, Loss Harmonics, Loss
Unbalance, Loss Neutral, Loss Cost (based upon user defined cost / kWh)
Wfull, Wfund, Wdc, Efficiency, Vdc, Adc, Vrms, Arms, Hz

Power and energy


Energy loss calculator
Inverter efficiency
(requires optional dc current clamp)

Included Accessories
TL430 test lead and alligator clip set,
i430flex-TF, 61 cm, 4 clamps,
BC430 power adapter,
BP290 single capacity Li-ion battery,
International plug adapter set,
WC100 color coding clips and regional decals,
8 GB SD card,
PowerLog on CD
USB cable A-Bmini
C1740 softcase (434-II, 435-II),
C437 hard case (437-II)

Ordering information
Fluke 434-II
Fluke 435-II
Fluke 437-II

Three-Phase Energy Analyzer


Three-Phase Power Quality
and Energy Analyzer
Three-Phase Power Quality
and Energy Analyzer

4 voltage waveforms, 4 current waveforms, Vrms, Vfund. Arms, A fund, V @ cursor,


A @ cursor, phase angles

Unbalance

Vneg%, Vzero%, Aneg%, Azero%, Vfund, Afund, V phase angles, A phase angles

Inrush

Inrush current, Inrush duration, Arms, Vrms

Monitor

Flicker (435-II and 437-II only)

Vrms, Arms, harmonic Volts, THD Volts, PLT, Vrms, Arms, Hz, dips, swells, interruptions, rapid
voltage changes, unbalance and mains signalling. All parameters are measured simultaneously
in accordance with EN50160 Flagging is applied according to IEC61000-4-30 to indicate unreliable
readings due to dips or swells
Pst(1min), Pst, Plt, Pinst, Vrms , Arms , Hz

Transients (435-II and 437-II only)

Transient waveforms 4x Voltage 4x Amps, triggers: Vrms , Arms , Pinst

Mains Signaling
(435-II and 437-II only)

Relative signaling voltage and absolute signaling voltage averaged over three seconds for up to two
selectable signaling frequencies

UPower Wave
(435-II and 437-II only)

Vrms, Arms W, Hz and scope waveforms for voltage amps and watts

Logger

Custom selection of up to 150 PQ parameters measured simultaneously on 4 phases

Battery life: 7 hours operating time per charge on Li-ion battery pack
Safety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV
Case: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2
Operating temperature: 0C to +50C
Size (HxWxD): 265 mm x 190 mm x 70 mm; Weight: 2.1 kg
Three Years Warranty

www.chorus.ro

Recommended Accessories

i430-FLEXI-TF-4PK
See page 98

i5sPQ3
See page 98

BP291
See page 86

See page 98 for power quality current clamps

93

1735 Power Logger


Performs electrical load studies, energy
consumption testing, and general power
quality logging
The Fluke 1735 Power Logger is the ideal
tool for electricians and maintenance
technicians for conducting energy
studies and basic power quality logging.
The 1735 is easy to set up with its color
display and four included new thinner
flexible current probes.

Fluke 1735

The 1735 logs most electrical power


parameters, harmonics and captures
voltage events. View graphs and generate
reports with the included Fluke Power
Log software.

View recorded data in simple graphs and


tables with Fluke Power Log software.

Record power and associated


parameters for up to 45 days
Monitor maximum power demand over
user-defined averaging periods
Prove the benefit of efficiency
improvements with energy
consumption tests
Measure harmonic distortion caused by
electronic loads
Improve reliability by capturing voltage
dips and swells from load switching
Confirm instrument setup easily with
color display of waveforms and trends

Conduct load studies


for up to 45 days and
view saved data
on-screen or on a
computer.

Access voltage and


current harmonics
up to the 50th.

Quantify energy
consumption quickly
on-screen or log to
memory for extended
periods.

Capture voltage events


using user-defined
thresholds.

Customize the report generator to easily


generate professional looking reports.

Specifications
(Check the Fluke web for detailed specifications)
Volts rms

Amps rms
Frequency
Harmonics and THD
Power measurement
(P - Active, S - Apparent, Q - Reactive, D - Distorting)
Energy Measurement (kWh, KVAh, kVARh)
PF (Power factor)
Events

General
Memory
Sample rate
Line frequency

Included Accessories
FS17X5-TF 4-phase flexible current clamp
set, VL1735/1745 voltage lead set, Power Log
software, color localization set, PC interface
cable, international ac adapter, BC1735 battery
charger, soft carrying case, printed English
manual and multi-language manual on CD.

V-rms wye measurement ranges:


57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/
400 V/417 V/480 V AC
V-rms delta measurement ranges:
100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/
690 V/720 V/830 V AC
Flexi set measurement range: 15 A/150 A/3000 A rms (at sine)
Current clamp measurement range: 1 A/10 A
Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
To 50th harmonic (< 50 % of nom)
Measuring range: see V-rms and A-rms measurement ranges
Measuring range: see V-rms and A-rms measurement rangeso
0.000 to 1.000
Detection of voltage dips, voltage swells and voltage interruptions with a
10 ms resolution and measuring error of the half period sine wave of rms.

4 MB Flash memory, 3.5 MB for measuring data


10.24 kHz
50 Hz or 60 Hz, user-selectable, with automatic synchronization

Display: VGA Graphic Color transmissive displays


320 x 240 pixels with additional background lighting
and adjustable contrast, text and graphics in color
Interface: USB with Mini USB B socket. Firmware
updates are possible with the USB interface
Housing: IP65; EN60529 (refers only to the main
housing without the battery compartment)

Power supply: NiMH battery-pack, with AC adapter


(15 V to 20 V/0.8 A)
Battery Life: Typical > 16 hours without backlight and
> 6 hours with backlight high
Operating temperature: 0C to +40C
Size (HxWxD): 240 mm x 180 mm x 110 mm
Weight: 1.7 kg, including battery
Two Year Warranty

Ordering Information
Fluke 1735
FS17X5-TF

www.chorus.ro
3000/6000A-TF-4

94

Power Logger
4-phase thin flexi current
clamp set, 3000 A
4-phase thin flexi current
clamp set, 6000 A

Recommended Accessories
See page 98 for power quality current clamps

1740 Series Three-Phase


Power Quality Loggers Memobox
Assess power quality and conduct long-term
studies with ease
Compact, rugged and reliable, the Fluke
1740 Series three-phase power quality
loggers are everyday instruments for
technicians who troubleshoot and
analyze power distribution systems.
Capable of simultaneously logging up
to 500 parameters for up to 85 days and
capturing events, the Fluke 1740 Series
helps uncover intermittent and hard-tofind power quality issues. There are three
models to choose from to meet your
basic or advanced power logging needs.
Fluke 1743

Fluke 1744

Fluke 1745

Fluke 1743: IP65 waterproof monitor


for logging the most common power
parameters including V, A, W, VA, VAR, PF,
energy, flicker, voltage events and THD.

Plug and play: Set up in minutes with


automatic current probe detection and
powering
Installs inside the cabinet: Compact,
fully-insulated housing and accessories
fit easily in tight spaces next to live
power
Monitors power for the long-term:
Data can be downloaded during
recording without interruption
Measure voltage with premium
accuracy: IEC61000-4-30 Class-A
compliant voltage accuracy (0.1%)
Quickly validate quality of power:
Assess power quality according to
EN50160 power quality standard with
statistical overview

Fluke 1744: Includes the same features


as the Fluke 1743. In addition to common
power parameters, the Fluke 1744 also
measures voltage and current harmonics,
interharmonics, mains signaling,
unbalance, and frequency.
Fluke 1745: Advanced IP50 power quality
logger with the same measurement
capability as the 1744, plus real-time LCD,
five hour UPS.

Specications

The included PQ Log software helps you


to quickly identify the root cause of a
disturbance.

Included Accessories
Fluke 1743/1744/1745: FS17XX IP65-TF thin
flexible current clamp set (1743 & 1744),
FS17X5-TF thin flexible current clamp set
(1745), VL1735/1745 voltage lead set (1745
only), Power Log software, RS232 interface
cable and RS232-USB adapter, 4 black dolphin
clips, WC17XX color localization set, carrying
bag, test certificate with measurement values,
printed English manual and multi-language
manual on CD.
Basic models: Excl. current clamps FS17XX-TF

Ordering Information
Fluke 1743 Basic
Fluke 1743
Fluke 1744 Basic
Fluke 1744
Fluke 1745

Power Quality Logger


Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox
Power Quality Logger
Memobox
4-phase thin flexi current
clamp set, 3000 A
4-phase thin flexi current
clamp set, 6000 A

(Check the Fluke web for detailed specications)

Measurement of common power parameters: V, A, W,


VA, VAR, PF, energy, flicker, voltage events (dips, swells,
interruptions), and THD
Measurement of voltage and current harmonics to the
50th, unbalance, frequency and mains signaling
Dust/water resistance
Display
Memory
UPS ride-through
EN 50160

3000/6000A-TF-4

1744
O

IP 50
LED + LCD
8 MB
> 5 hrs
O

LED
8 MB
3s
O

Power supply: 88 V 660 V AC


Safety: IEC/EN 61010-1 600 V CAT III, 300 V
CAT IV, pollution degree 2, double insulation
Housing: Fully insulated housing and accessories
Operating temperature: 0 C to 35C
Interface: RS 232, 9600 ... 115 000 Baud, automatic
Baud rate selection, 3-wire communication

www.chorus.ro
FS17x5-TF

1745
O

1743
O

IP 65 waterproof
LED
8 MB
3s
O

Fluke 1745: 282 mm x 216 mm x 74 mm;


Fluke 1743/44: 170 mm x 125 mm x 55 mm
Weight: Fluke 1745 approx. 3 kg;
Fluke 1743/44: approx. 2 kg
Two Year Warranty
Size:

See page 98 for power quality current clamps


95

1750 Three-Phase Power


Recorder
Never miss capturing a disturbance
With its exclusive threshold-free
measurement system, the Fluke
1750 Power Recorder captures every
measurement, every event, on every cycle,
all the time. Outstanding accuracy and
resolution provide complete visibility into
your installation or distribution system.
On all inputs

Power quality that meets the standard:


All measurements comply with
IEC61000-4-30 standards for correct
evaluation of all measured values
including voltage, current, power,
harmonics, flicker etc.
Quick and reliable configuration: PDA
wireless front panel interface provides
the ability to verify setup without a
laptop along with a window into what
the instrument is recording, even in
awkward test locations.
Threshold-free setup: Apply thresholds
after data is collected with Fluke Power
Analyzer Software so there is no need to
worry about missed information due to
incorrect set-up.

Captures everything: Cross-channel


and current triggering capture every
measurement, on every channel, every
time.
Intuitive PC software: Easily analyze
data and generate reports. Automated
EN50160 reporting and compliance.
Plug and play: Set up in minutes with
selfidentifying current probes and
single-lead voltage connections.
No need to reconnect wires: Swap
channels internally with the wireless
PDA or PC when connections are not
correct.
Measure every parameter: Voltage and
current on three phases, neutral, and
ground.
5 MHz, 8000 Vpk waveform capture:
Get a detailed picture of even the
shortest events.
Quickly retrieve data: With included SD
memory card or via the 100BaseT highspeed Ethernetv connection

View measurements real time with wireless PDA interface

Specifications
(Check the Fluke web for detailed specifications)
Power quality measurement standards
Conformance
Clock/calendar
Real-time clock accuracy
Internal memory capacity for data
Maximum recording period
Measurement time control
Maximum number of events
Power requirements
Operating time during interruptions (internal UPS operation)

Included Accessories
PDA and charger power plug adapters,
4 current probes, 5 test leads and clips, SD
memory card., Fluke Power View and Fluke
Power Analyze software, power cord with
international plug set, Ethernet cable, color
localization set, soft carrying case, Printed
Getting Started manual, CD with software and
users manual PDF
Basic model: excl. 4 current probes

Ordering Information
Fluke 1750/B

Leap years, 24-hour clock


Not more than 1 s/day
At least 1 GB
At least 31 days
Automatic
Limited only by the size of the internal memory
100 to 240 V rms 10 %, 47-63 Hz, 40 W
5 minutes per interruption, 60 minutes total operating time without recharging

Safety: EN 61010-1 2nd Edition; 2000


Weight: 6.3 kg
Size (H x W x D): 215 x 310 x 35 mm
One Year Warranty

Recommended Accessories
Model
3210-PR-TF
3310-PR-TF
3312-PR-TF
3140-PR
i40S-PR
i4S-PR
FLUKE-1750/SEAT-L
FLUKE-1750/SITE-L
FLUKE-1750/CASE
CS1750
HP IPAQ 2490
FLUKE-1750/MC

www.chorus.ro
Fluke 1750

96

Three-Phase Basic Power


Recorder
Three-Phase Power Recorder

IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160

Description
1000A Thin flexible current transformer 61 cm (24") (20 A - 1000 A)
5000A Thin flexible current transformer 61 cm (24") (100 A - 5000 A)
5000A Thin flexible current transformer 122 cm (48") (100 A - 5000 A)
Clamp-on current transformer (2 A - 400 A)
Clamp-on current transformer (0,1 A - 40 A)
Clamp-on current transformer (0,01 A - 5 A)
Fluke Power Analyze Additional SEAT LICENSE
Fluke Power Analyze Additional SITE LICENSE
Hard Case
Soft Case
Additional Wireless Interface PDA
Additional 512 MB SD Memory Card

1760 Three-Phase Power


Quality Recorder Topas
Class-A compliance for the most demanding
power quality tests

Fluke 1760

The Fluke 1760 Three-Phase Power


Quality Recorder is fully compliant to
IEC 61000-4-30 Class-A, for advanced
power quality analysis and consistent
compliance testing. Designed for analysis
of utility and industrial power distribution
systems, in medium and low-voltage
networks, the Fluke 1760 provides the
flexibility to customize thresholds,
algorithms, and measurement selections.
It has 8 input channels (4 currents/4
voltages or 8 voltages), and captures the
most comprehensive details on user
selectable parameters.

GPS time synchronization: Correlate


data with events or datasets from other
instruments with precision
Uninterrupted power supply
(40 minutes): Never miss important
events - even record the beginning and
end of interruptions and outages
10 MHz, 6000 Vpk waveform capture:
Get a detailed picture of even the
shortest event
2 GB data memory: Enables detailed,
simultaneous recording of numerous
power parameters for long periods of
time
Includes Comprehensive software:
Provides trend diagrams for root cause
analysis, statistical summaries, report
writing and real-time data monitoring
in the online mode

Features
(Check the Fluke web for detailed specifications)
Power quality statistics according to EN50160
Voltage event list (dips, swells and interruptions)
Continuous recording of:
Voltage
Current
Power P, Q, S
Power factor
kWh
Flicker
Unbalance
Frequency
Voltage and current harmonics to the 50th/
Interharmonics
THD
Mains signaling
Triggered recordings
Online mode (Oscilloscope, transients and events)
Fast transient analysis up to 10 MHz
4 voltage probes
4 dual-range flexible current probes (1000 A / 200 A ac)
GPS time sync receiver
Memory

The included PQ Analyze software


provides a detailed overview of several
power quality parameters on one
dashboard according to the EN50160
power quality standard.

Included Accessories

4 x TPS Flex 24-TF flexible current probe, 4 x TPS


VoltProbe 600V, 2 GB internal flash memory, ST1760
standard Ethernet cable, RS232 interface cable and
RS232-USB adapter, CS1760 crossover Ethernet cable,
1 mains cable, PC software on CD-ROM, WC17xx
color localization set, GPS-time sync (1760TR only)
CS 1750/1760 carrying bag, hardware and software
manual
Basic models: Excl. current clamps TPS Flex 24-TF

Ordering Information
Fluke 1760 Basic
Fluke 1760TR Basic
Fluke 1760
Fluke 1760TR

Power Quality Recorder Topas


Power Quality Recorder Topas
Power Quality Recorder Topas
Power Quality Recorder Topas

1760 Basic

1760TR Basic

1760

1760TR

O
O

O
O

O
O

O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O
O

O
O
O
O

O
O
O
O
O

O
O
O
O

O
O
O
O
O
O
O
O

O
O
O
2 GB Flash memory

Power supply: 83 V to 264 V, 45 to 65 Hz


Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes
back-up power supply)
Safety: 600V CAT IV/1000V CAT III
(Rated for use at the service entrance)
Housing: Fully insulated robust plastic housing

Operating temperature: 0 C to 35C


Interfaces:
Ethernet (100 MB/s), RS-232, external
modem via RS-232
Size (HxWxD): 325 mm x 300 mm x 65 mm
Weight: Approxiamtely 4.9 kg
Two Year Warranty

Recommended Accessories
(Check the Fluke web for complete accessory list)
Model
TPS VOLTPROBE 10 V
TPS VOLTPROBE 100 V
TPS VOLTPROBE 400 V
TPS VOLTPROBE 600 V
TPS VOLTPROBE 1 KV
TPS FLEX 18-TF
TPS FLEX 24-TF
TPS FLEX 36-TF
TPS CLAMP 10 A / 1 A
TPS CLAMP 50 A / 5A
TPS CLAMP 200 A / 20 A
TPS SHUNT 20 MA
TPS SHUNT 5 A

www.chorus.ro

Description
10 V Voltage Probes (Range: 0.1 V to 17 V)
100 V Voltage Probes (Range: 1 V to 170 V)
400 V Voltage Probes (Range: 4 V to 680 V)
600 V Voltage Probes (Range: 10 V to 1000 V)
1000 V Voltage Probes (Range: 10 V to 1700 V)
Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)
Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)
Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)
Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)
Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)
Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A)
20 mA ac/dc Shunt (Range: 0 to 55 mA)
5 A ac/dc Shunt (Range: 0 to 10 A)

97

Fluke model number

98

www.chorus.ro

Basic accuracy: % reading plus floorspec.


n/a = not applicable

BNC to banana adapters included

One
connector
n/a

2
CAT III 600 V

75 mV/A

40 Hz ... 10
kHz

20 A
10 mA
0.5%

i3000 flex-4PK
(4x i3000s flex24)

One
connector
n/a

2
CAT III 600 V

Output cable (m)


Safety rating

Connection

75 mV/A

40 Hz ... 10
kHz

20 A
10 mA
0.5%

10 mA ... 1 A
100 mA ...
10 A

1A
10 A AC

1A
10 A AC

10 mA ... 1 A
100 mA ...
10 A

O
O

MBX CLAMP
1A/10A+N
(EPO451A)

4 ... phase
1A/10A Mini
current
clamp set

i1A/10A
CLAMP PQ4

O
O

CURRENT
CLAMPS 1A
(EPO450A)

3 ... phase
1A/10A Mini
current
clamp set

Output level(s)

Requires battery
Flex head length

Usable frequency

Highest current
Lowest measurable current
Basic accuracy (48 ... 65 Hz) 1)

Cont. AC current range

Fluke 1735
Fluke 174X
Fluke 43X
Nominal current range(s)

Old Fluke model #

Description

i1A/10A
CLAMP PQ3

One
connector
n/a

2
CAT III 600 V

15 mV/A

40 Hz ... 10
kHz

100 A
50 mA
0.5%

50 mA ... 5 A
500 mA ...
50 A

5A
50 A AC

O
O

MBX CLAMP
5A/50A
(EPO452A)

3 ... phase
5A/50A Mini
current
clamp set

i5A/50A
CLAMP PQ3

i400s

One
connector
n/a

2
CAT III 600 V

15 mV/A

40 Hz ... 10
kHz

100 A
50 mA
0.5%

50 mA ... 5A
500 mA ...
50 A

5A
50 A AC

O
O

MBX CLAMP
5A/50A+N
(EPO453A)

4 ... phase
5A/50A Mini
current
clamp set

i5A/50A
CLAMP PQ4

One
connector
n/a

2
CAT III 600 V

3.75 mV/A

40 Hz ... 10
kHz

300 A
200 mA
0.5%

200 mA ...
20 A
2 A ... 200 A

20 A
200 A AC

O
O

MBX CLAMP
20A/200A
(EPO455A)

3 ... phase
20A/200A
Mini current
clamp set

i20A/200A
CLAMP PQ3

One
connector
n/a

4
CAT III 1000 V
CAT IV 600V

92 cm

0.8 A

30A 300A
3000A 6000A
AC
0.8 ... 6.000 A
AC

O
O

4 Phase
flexiset

3000/6000A-TF-4

i430-FLEXI-TF-4PK

One
connector
n/a

2
CAT III 600 V

3.75 mV/A

40 Hz ... 10
kHz

300 A
200 mA
0.5%

200 mA ...
20 A
2 A ... 200 A

20 A
200 A AC

O
O

MBX CLAMP
20/2000A+N
(EPO456A)

4 ... phase
20A/2000A
Mini current
clamp set

i20A/200A
CLAMP PQ4

15A 150A
1500A 3000A
AC
450mA
15A 600mA
150A 6A
1500A 12A
3000A
3300 A
450 mA

MBX
Lem Flex
(15/150/3000)
(EP0404A)
O
O

4 Phase
flexiset,
IP65

FS17xx IP65-TF

One
connector
n/a

2
CAT III 1000 V
CAT IV 600V

0.1 mV/A

61 cm

40Hz 5kHz

i5sPQ3

One
connector
n/a

2
CAT III 1000 V
CAT IV 600V

0.1 mV/A

61 cm

40Hz 5kHz

2%+2% position 2%+2% position


influence
influence

15A 150A
1500A 3000A
AC
450mA
15A 600mA
150A 6A
1500A 12A
3000A
3300 A
450 mA

MBX
Lem Flex
(15/150/3000)
(EP0404A)
O
O

4 Phase
flexiset,
IP41

FS17X5-TF

4 x BNC

10 mV/A
1 mV/A
0.1 mV/A
2.1
CAT III 600 V

10 Hz ... 100
kHz
O

4000 A
1A
2% + 2 A

O
30 A
300 A
3000 A
1 A ... 30 A
1 A ... 300 A
1 A ... 2400 A

4 ... phase
3000A
Flexible
current
clamp set

i3000 flex ... 4PK

4 x BNC

2.5
CAT III 1000 V
CAT IV 600 V

Clamp
opening:
32 mm
10 mV/A
1 mV/A

45 Hz ... 3
kHz

1000 A
0.5 A
2% + 0.15 A

0.5 A ... 40 A
5 A ... 400 A

O
40 A
400 A

Single phase
400A current
clamp
(4 required)

i400s

4 x BNC

2.5
CAT III 1000 V
CAT IV 600 V

0.085 mV/A
@50 Hz

61 cm

10 Hz ... 7
kHz

100 kA
30 A
1%

30 A ...
3000 A

O
3000 A

4 ... phase
3000A
Flexible
current
clamp set

i430-FLEXI-TF-4PK

3 x BNC

2.5
CAT III 600 V

Clamp
opening:
15 mm
400 mV/A

40 Hz ... 5
kHz

70 A
10 mA
1%

0.01 A ... 6 A

O
5A

3 ... phase 5A
Current
clamp
set

i5sPQ3

Power Quality Current Clamps

Norma 4000/5000
Power Analyzers
Reliable, highly accurate measurements for
the test & development of power electronics

Fluke Norma Series Power Analyzers

The compact Fluke Norma Series


Power Analyzers provide the latest
measurement technology to assist
engineers with the development and
testing of motors, inverters, lighting,
power supplies, transformers and
automotive components.

The Series consists of the Fluke Norma


4000 Three-Phase Power Analyzer and
the Fluke Norma 5000 Six-Phase Power
Analyzer. These rugged analyzers provide
unmatched price performance for easy
and reliable use in the field, or as a bench
unit in laboratories and on test benches.

Based on a patented, high-bandwidth


architecture, the instruments deliver
high-precision measurements of single
or three-phase current and voltage,
harmonics analysis, Fast Fourier
Transformation (FFT) analysis, as well as
calculations of power and other derived
values.

Simple user interface ensures easy,


intuitive operation
Unique user-configurable modular
design
Simultaneous parallel acquisition of all
phases
Voltage, current and power harmonics
up to the 40th
Includes FFT analysis, vector diagram
display, recorder function, and Digital
Oscilloscope (DSO) mode
User selectable average time from
15ms to 3600s
Expandable on-board memory for
storage of measured values

A unique user-configurable system


design with plug-in power phases and
other optional modules provides the
flexibility to meet a variety of application
measurement requirements. Recorded
data and waveforms can be viewed
clearly in the large color display and
easily downloaded to a PC for analysis
and report writing.
Fluke Norma 4000

Fast Fourier
Transformation (FFT)
analysis

Digital Oscilloscop
(DSO) mode

Vector Display

Recorder function

Specifications
(Check the Fluke web for detailed specifications)

Fluke Norma 5000

Included Accessories

Number of Phases
Weight
Size (HxWxD)
On-board Printer
Display
Bandwidth
Basic Accuracy
Sampling Rate
Voltage Input Range
Current Input Range (direct, not via shunt)
Memory for Configurations
Memory for Settings
Fast Fourier Transformation (FFT)
RS232 Interface
PI1 Process Interface (8 analog/impulse inputs and
4 analog outputs)
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet /
10 MBit/s or 100 Mbit/s)
Fluke NormaView PC Software (for data download,
analysis & report writing)

Fluke Norma 4000


Fluke Norma 5000
1 or 3
3, 4 or 6
Approx. 5 kg
Approx. 7 kg
15 cm x 23.7 cm x 31.5 cm
15 cm x 44.7 cm x 31.5 cm
No
Yes (optional)
Color, 5.7 / 144 mm - 320 x 240 pixel
dc to 3 MHz or dc to 10MHz depending on input module
0.2%, 0.1% or 0.03% depending on input modules
0.33 MHz or 1 MHz depending on input modules
0.3 V to 1000 V
0.03 mA 20 A depending on input module
4 MB, expandable to 128 MB
0.5 MB
To the 40th harmonic
Standard
Optional
Optional
Standard

Power Supply Cable, RS232 Interface and USB


adaptor for Data Download, Fluke NormaView
PC Software, Users Manual, Test Certificate,
and Calibration Values.

Ordering Information
Fluke Norma 4000

Three-Phase High
Precision Power Analyzer
Six-Phase High Precision
Power Analyzer

Operating temperature:
+ 5 C to 35 C
Storage temperature:
- 20 C to 50 C
Climatic class: KYG DIN 40040, maximum
85% relative humidity, non-condensing.

www.chorus.ro
Fluke Norma 5000

Housing: Solid metal case


Safety: EN 61010-1 / 2nd Edition, 1000 V CAT II
(600 V CAT III)
Two Year Warranty

99

Norma 4000/5000
Power Analyzer Accessories
Power Phases

Fluke Norma 4000 (rear view)

The Fluke Norma 4000 Power Analyzer


can be equipped with up to three power
phases and the Fluke Norma 5000 Power
Analyzer can be equipped with up to six
power phases. Users can select the power
phase best suited for their application.
Specifications vary depending on the model
of the power phase.

Each plug-in power phase consists of


a voltage and a current measurement
channel. Each measuring channel is
available for each basic unit.

Power Phase Overview


Channel
Accuracy
Current range
Sampling rate
Bandwidth

3024770
PP42
0.2%
(0.1% rd + 0.1% rg)
20 A
341 kHz
3 MHz

3024812
PP50

3024820
PP54

0.1%
0.05% rd + 0.05% rg
10 A
10 A
1 MHz
341 kHz
10 MHz
3 MHz

3024835
PP64
0.03%
(0.02% rg + 0.01% rg)
10 A
341 kHz
3 MHz

Fluke Norma 5000 (rear view)

Shunts
The input modules can take up to 10 A
or 20 A directly or measure current via
wideband precision shunts. The available
range of shunts enables measurements up
to 1500 A and can be used in conjunction
with all of the available input modules.

3024677
3024689
3024886
3024899
3024847
3024858
3024864
3024873
3024692

32 A Planar Shunt
Cables for 32 A Planar Shunt
10 A Triaxial Shunt with Cables
(0.333 ., 0 to 0.5 MHz)
30 A Triaxial Shunt with Cables
(0.010 ., 0 to 0.5 MHz)
100 A Shunt with Cables (0.001 , 0 to 0.5 MHz)
150 A Shunt with Cables (0.5 m, 0 to 0.5 MHz)
300 A Shunt with Cables (0.1 m, 0 to 1 MHz)
500 A Shunt with Cables (0.1 m, 0 to 0.2 MHz)
LG Shunt Cables for High Current Shunts

Cables & Adaptors


3024661
3024704

Measurement Cable Set (for one power phase)


Fluke Norma WYE Adaptor (external accessory
box)

Printer Accessories
3024650

Printer Cable for Fluke Norma 5000


(RS232-Centronics)

www.chorus.ro

All accessories have a


two-year warranty.

100

Optional shunts for Fluke Norma Series Power


Analyzers

32 A Planar Shunt

Field Calibrators
Fluke process calibration tools include a full range of calibrators and
troubleshooting tools for instrument technicians working in the process
industries. The range of process calibrators include: Documenting
Process Calibrators, Multifunction Process Calibrators, single function
and multifunction temperature calibrators, a variety of mA loop
calibrators and a range of intrinsically safe products.

www.chorus.ro

101

102

O
O
O

26 V

O
3
103

O
O
O

26 V

O
3
103

15 V
10 k
22 mA
O
50 kHz
8
13

8
13

15 V
10 k
22 mA
O
50 kHz
8
13

Fluke 700 pressure modules required


Ranges for the internal sensor.
Ranges for use of Fluke 700 pressure modules, see page 108.

Record
Min/Max
Hold
As Found/As Left results
Log data
Upload data to PC
Remote operation
Features
Loop supply
Hart communication
Integrated hand pressure pump
Electric Pump
Intrinsically safe (ATEX)
NIST traceable certification
Warranty in years
See catalog page

Source/Simulate
Voltage DC
Resistance
mA DC/% scale
mA source; auto step, auto ramp
Frequency
Temperature: RTD types
Temperature: TC types

8
13

50 kHz
O1

Current AC
Frequency
Pressure

Temperature: RTD types


Temperature: TC types

300 V
300 V
10 k
110 mA

300 V
300 V
10 k
110 mA

50 kHz
O1

753

754

www.chorus.ro

Model
Measure
Voltage DC
Voltage AC (true RMS)
Resistance
Current DC

Documenting Process
Calibators

24 V

O
3
104

725Ex
O
3
104

20 V
4000
24 mA
O
15 kHz
8
10

8
12

24 V/12 V

O/-

10 V
3200
24 mA
O
10 kHz
7
10

7
12

15 kHz
O1

4000
24 mA

3200
24 mA

10 kHz
O1

30V

726

30 V

725/725Ex

Multifunction Process
Calibrator

O
3
105

24 V

7
10

10 V
3200

7
12

3200
24 mA

30 V

724

O
3
106

75 mV

75 mV

714

O
3
106

3200

3200

712

Temperature Calibrators

718Ex
O
3
108

24 V/-

O
O

68,9 mbar
to 20 bar /
2 to 7 bar2

24 mA

718/718Ex

O
3
108

24 V

O
O

68,9 mbar
to 345 bar2

24 mA

717

719

O
3
108

24 V

O
O

2 bar to
7 bar2

24 mA

Pressure Calibrators

O
3
109

24 V

24 mA
O

10 V

24 mA

10 V

715

707Ex
O
3
109

24 V

24 mA
O

24 mA

28 V

707/707Ex

3
110

100 mA

771

3
110

24 V

24 mA
O

100 mA

772

Loop Calibrators

3
110

24 V

24 mA
O

10 V

100 mA

30 V

773

O
3
109

24 V

24 mA
O

24 mA

28 V

705

3
111

24 V

O
O

24 mA
O

1000 V
1000 V
40 M
30 mA,
1A
O
20 kHz

789

3
111

O
O

24 mA
O

O
20 kHz

1000 V
1000 V
40 M
30 mA, 1A

787

ProcessMeters

Field Calibrator
Selection Guide

750 Series Documenting


Process Calibrators
New

Work smarter. Work faster

Fluke 754

Fluke 753

Whether youre calibrating instruments,


troubleshooting a problem or running
routine maintenance, Fluke 750 series
process calibrators can help you get the
job done faster. It does so many different
tasks, so quickly and so well, its the only
process calibrator you need to carry.
Measure volts, mA, RTDs,
thermocouples, frequency, and ohms
to test sensors, transmitters and other
instruments
Source/simulate volts, mA,
thermocouples , RTDs, frequency, ohms,
and pressure to calibrate transmitters
Power transmitters during test using
loop supply with simultaneous mA
measurement
Measure/source pressure using any of
29 Fluke pressure modules
Measure and source simultaneously
with one compact, rugged, reliable tool
Create and run automated as-found/
as-left procedures to satisfy quality
programs or regulations. Record and
document results
Advanced features like autostep,
custom units, user entered values
during test, one-point and two-point
switch testing, square root DP flow
testing, programmable measurement
delay and more
Control the temperature of selected
Hart Scientific Dry Blocks
Handle fast pulsed RTD transmitters
and PLCs in RTD source mode with
1 ms response time
English, French, German, Italian, and
Spanish languages
Three-year warranty

753: A complete documenting


calibrator
The 753 Documenting Process Calibrator
automates calibration procedures and
captures your data. Use the PC interface
for downloading procedures, lists, and
instructions to the 753 and for uploading
data for printing, archiving and analysis.

754: Get HART-ability


The 754 offers all of the capabilities
of the 753, plus integrated HART
communication capability. This rugged,
reliable tool is ideal for calibrating,
maintaining, and troubleshooting HART
and other instrumentation.

Instrumentation Management
Software
The Fluke 753 and 754 are compatible
with Fluke 700SW DPC/TRACK software
and with software from Cornerstone,
Fisher-Rosemont, Honeywell, Yokogawa,
Prime Technologies and On Time Support.

Specifications
Included Accessories
Stackable test leads (3 sets), TP220 test probes
(3 sets) with extended tooth alligator clips
(3 sets), AC280 hook clips (2 sets), BP7240
Li-ion battery pack, BC7240 battery charger,
C799 field soft case, USB communication
cable, getting started guide, instruction
manual on CDROM, NIST traceable certificate
of calibration, DPCTrack 2 sample
software that enables upload and printing
of calibration records. HART communication
cable (754 only).

Ordering Information
Fluke 753
Fluke 754
700 TLK
BP7240
750 SW
BC7240
754HCC

Documenting Process Calibrator


Documenting Process Calibrator
Process test lead kit
753/754 Spare battery
DPC/Track2
753/754 Battery charger/eliminator
754 HART communication cable

(Check the Fluke web for detailed specifications)


Function
Voltage DC
Current DC
Resistance
Frequency
Thermocouples
RTDs
Pressure

Measure
Sourcing
0.02% + 0.005 mV
0.01% + 0.005 mV
0.01% + 5 A
0.01% + 0.003 mA
0.05% reading + 50 m
0.01% output + 10 m
0.05 Hz
0.01 Hz
0.3C
0.2C
0.07 C
0.06 C
To 0.05% of full scale. See Pressure Module specifications.

Operating temperature: -10 C to 50 C


Storage temperature: -20 C to 60 C
Safety: CAT II 300V
Battery Life: Typically over eight hours
Internal Battery Pack: li-ion, 7.2V, 4400 mAh,
30 Wh

Battery Replacement: Via snap-shut door without opening calibrator; no tools required
Weight: 1.2 kg
Size (HxWxD): 245 mm x 136 mm x 63 mm
Three Year Warranty

Recommended Accessories

www.chorus.ro
C799
See page 130

TL220-1
See page 122

80PK-8
See page 128

80PK-25
See page 128

700P27
See page 112

103

725/725Ex/726 Multifunction
Process Calibrators
More calibration power!

Fluke 725

Fluke 726

Fluke 725Ex

Features
Simultaneous Function
Capability
24.000 mA DC
24.000 mA DC with
24 V loop supply
100.00 mV DC
30.000V DC measure
20.000V DC Measure
10.000V DC Source
20.000V DC Source
15 to 3200 Ohms
5 to 4000 Ohms
Thermocouple J, K, T, E, R, S, B, M,
L, U, N, XK, BP
RTD Cu 10, Ni120; Pt100 (392);
Pt100 (JIS); Pt100, 200, 500, 1000
(385)
Pressure (requires Fluke 700 PXX
Modules)
Frequency; 10 kHz; (15 kHz)

Channel A

Channel B

M
M

M or S
M or S

M or S
M or S
M or S
M or S
M or S
M or S

725/725Ex/726 Multifunction
Process Calibrators

726 Precision Multifunction


Process Calibrator

Two separate channels; measure, source


and view process signals simultaneously
Measure volts, mA, RTDs,
thermocouples, frequency, and
resistance to test sensors and
transmitters
Source/simulate volts, mA,
thermocouples, RTDs, frequency, and
pressure to calibrate transmitters
Measure or *source pressure using any
of 29 Fluke 700Pxx Pressure Modules
Source mA with simultaneous pressure
measurement to conduct valve and I/P
tests
Perform fast linearity tests with auto
step and auto ramp features
Power transmitters during test using
24 V loop supply and simultaneous mA
measurement
Store frequently-used test setups for
later use
For 725Ex version see also page 118 and
119
*Pressure pump required

Additional features:
More precise measurement and
calibration source performance,
accuracies of 0.01%
Transmitter error% calculation
Memory storage for up to 8 calibration
results
Frequency totalizer and frequency
pulse train source mode for enhanced
flowmeter testing
HART mode inserts 250 ohm
resistor in mA measure and source
for compatibility with HART
instrumentation
Integrated pressure switch test allows
you to capture the set, reset and
deadband of a switch
Custom RTD curves, add calibration
constants for certified RTD probes for
enhanced temperature measurement

Function
Measure or Source
Voltage

Range or Type

Resolution

Accuracy

Notes

0 to 100 mV
725: 0 to 10V (source)
0 to 20V (source)
725/726: 0 to 30V (measure)
0 to 24

0.01 mV
0.001 V
0.001 V
0.001 V
0.001 mA

0.01%
0.02% Rdg + 2 LSD

Max load, 1 mA

0.01%; 0.02% Rdg


+2 LSD

Max load,
725/726: 1000
725Ex: 250

mV
(TC terminals)

-10.00 mV to +75.00 mV

0.01 mV

Ohms

15 to 3200
5 to 4000
2.0 to 1000 CPM
1 to 1100 Hz
1.0 to 10.0 kHz
10.0 to 15.0 kHz

0.01 to 0.1
0.1 CPM
1 Hz
0.1 kHz
0.1 kHz

0.01%
0.02% of range +
1 LSD
0.10 to 1.0
0.015%
0.05%
0.05%
0.25%
0.05%

N/A

10%

T/C

725/726: 24 V DC
725Ex: 12 V DC
J, K, T, E, L, N, U, XK

0.1 C, 0.1 F

T/C

B, R, S, BP

1 C, 1 F

RTDs

Cu (10), Ni 120 (672)


Pt 100, 200, 500, 1000 (385)
Pt 100 (3916),
Pt 100 (3926)

0.01 C
0.01 F

to 0.7 C
to 0.2 C
to 1.7 C
to 1.2 C
to 0.15 C

mA

Hz - CPM

M used as S
M or S

M = Measure S = Source/Simulate
Unique 726 features are in bold
725Ex: ATEX cerfified
(Ex ATEX II IG EEX 1a IIB 171C)

Included Accessories
Test Leads, AC172 Test Clips, one pair of
stackable test leads, users Manuals on
CD-ROM (725Ex also includes CCD control
drawing, Statement of Quality Assurance
Practices, NIST Traceable calibration
certificate)

Specifications

Unique 726 features are in bold

Loop Supply

Maximum voltage: 30V


Operating temperature: 10C to 55C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

0.1 C, 0.1 F

Source;
5V p-p
1V - 20 V p-p
squarewave,
-0.1 V offset

to 0.2 C

Size (HxWxD): 200 mm x 96 mm x 47 mm


Weight: 0.65 kg
Battery: Four AA alkaline batteries.
Battery life: 25 hours typical; battery door
Warranty: Three years

Recommended Accessories
(Not for hazardous zones)

Ordering Information

104

Fluke 725
Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726
Precision Multifunction Process
Calibrator

www.chorus.ro
C125
See page 130

TL220-1
See page 122

80PK-27
See page 128

TPAK
See page 132

700P27
See page 112

724 Temperature Calibrator


The temperature solution
The Fluke 724 Temperature Calibrator is
a powerful yet easy-to-use calibrator. Use
the measure and source functions to test
and calibrate almost any temperature
instrument.
Easy to read dual display lets you view
input and output simultaneously
Measure RTDs, thermocouples,
ohms, and volts to test sensors and
transmitters
Source/simulate thermocouples, RTDs,
volts, and ohms to calibrate transmitters
Perform fast linearity tests with 25% and
100% steps

Execute remote tests with auto step and


auto ramp
Power transmitters during test using
loop power supply with simultaneous
mA measurement
Store frequently-used test setups for
later use

Features
Simultaneous Function
Capability
24.000 mA DC
24.000 mA DC with 24V loop
supply
100.00 mV DC
30.000V DC Measure
20.000V DC Measure 10.000V
DC Source
0 to 3200 Ohms
Thermocouple J, K, T, E, R, S, B,
L, U, N
RTD Ni120; Pt100 (3926); Pt100
(JIS); Pt100, 200, 500, 1000 (385)

Fluke 724

M = Measure

Channel A

Channel B

M
M
M or S
M
M or S
M or S
M or S
M or S

S = Source/Simulate

Specifications
Function
Measure or Source
Voltage

Range

Resolution

Accuracy

Notes

0 to 100 mV

0.01 mV

0.02% Rdg + 2 LSD

Max load, 1 mA

mA (measure)

0 to 10V (source)
0 to 30V (measure)
0 to 24 mA

0.01 V
0.001 V
0.001 mA

0.02% Rdg +2 LSD

Max load,
1000

mV

-10.00 mV to +75.00 mV

0.01 mV

Resistance

0 to 3200 (measure)
15 to 3200 (source)
24V DC
J, K, T, E, L, N, U
B, R, S
Ni120 (672)
Pt 100, 200, 500, 1000 (385)
Pt 100 (3916)
Pt 100 (3926)

Loop Supply
Thermocouples
Thermocouples
RTDs

Included Accessories
Test Leads, AC172 Test Clips, one pair of
stackable test leads.

Maximum voltage: 30V


Operating temperature: -10C to 55C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

0.01 to 0.1

0.025% of range +
1 LSD
0.10 to 1.0

N/A
0.1 C
1 C
0.1 C

10%
to 0.7 C
to 1.4 C
to 0.2 C

Size (HxWxD): 200 mm x 96 mm x 47 mm


Weight: 0.65 kg
Battery: Four AA alkaline batteries
Battery life: 25 hours typical; battery door
Three Year Warranty

Ordering Information
Fluke 724

Temperature Calibrator

Recommended Accessories

www.chorus.ro
C25
See page 130

TL220-1
See page 122

TL81A
See page 121

80PK-25
See page 128

80PK-3A
See page 128

105

712/714 Temperature Calibrators


The clear choice
The Fluke 710 Series Process Calibrators
offer clear new choices in single-function
calibrators. Whatever you want to
measure - temperature, pressure or basic
electrical parameters - youll find one of
these easy-to-carry handheld tools gives
you exactly the functions you need. They
combine the rugged, ready-for-action
package of the proven Fluke 80 Series
DMMs with the easy-to-use pushbutton
operation of the multifunction Fluke 740
Series Documenting Process Calibrators.
These calibrators are EMI tolerant,
dust and splash resistant, and have a
removable battery door for quick battery
changes.

Fluke 714

712 RTD Calibrator


Measure temperature from RTD output
Simulate RTD output
Rosemount pulsed RTD transmitter
compatible
Operates with seven types of RTDs
Measure additional RTDs using Ohms
measurement function
Simulate additional RTDs using Ohms
source function
F or C selectable
Four shrouded banana jacks

714 Thermocouple Calibrator


Measure temperature from TC output
Simulate TC output
Operable with nine types of
thermocouples
Calibrate linear TC transmitter with
mV source function
Selectable F or C
Thermocouple mini-jack termination
Available as accessories; Fluke 700 TC1
and TC2 Thermocouple Mini-plug Kits

Fluke 712

Specications
Model
Fluke 712

Fluke 714

Function
Measure/
simulate RTD

Range
-200 to 800C
(Pt 100)

Resolution
0.1C, 0.1F

Accuracy
0.33C, 0.6F
(Pt 100)

Measure/
simulate
Resistance
Measure/
simulate
Thermocouple

15 to 3200

0.1

0.1 to 1

-200 to 1800C,
depending on
type (K, -200 to
1370C)
-10 to 75 mv

0.1C or F
(1C or F; BRS)

0.3C to 10 V

0.01 mV

0.025% +
1 count

Measure/
simulate mV

Included Accessories
Yellow Holster (H80M excl. TPAK), Test Leads
and AC172 Alligator Clips (excluding model
714), single 9V alkaline battery and Instruction
Sheet (14 languages)

Maximum voltage: 30 V
Operating temperature: -10C to 55C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:
1994 Class B

Notes
Pt; 100, 200, 500,
1000 (385);
Pt 100 (3926);
Pt 100 (3916) JIS;
Ni 120 (672)

9 TC types:
J K T E R S B per NIST
175 and ITS-90, L U per
DIN 43710 and IPTS-68

Size (HxWxD): 201mm x 98 mm x 52 mm


Weight: 0.6kg
Battery: 9V alkaline
Battery Life: 4 to 20 hours, typical, depending
on functions used
Three Year Warranty

Ordering Information
Fluke 712
Fluke 714

RTD Calibrator
Thermocouple Calibrator

Recommended Accessories

www.chorus.ro
C25
See page 130

106

C550
See page 130

TL970
See page 121

TL220-1 (714)
See page 122

80PK-24 (714)
See page 128

9140 Series Field Metrology Wells


4180 Series Infrared Calibrators
Field Metrology Wells and infrared
calibration targets

Fluke 9142/9143/9144

9142, 9143, 9144


Field temperature calibration with
precision and speed

4180/4181 IR Calibrators
True metrology solution for infrared
Calibration

The Fluke 9140 series Field Metrology


Wells extend high performance portable
temperature calibration to the industrial
process environment by maximizing
portability, speed, and functionality
with little compromise to metrology
performance.

Now its easy to increase your IR


temperature measurement accuracy in
the lab or the field with the new 4180/81
Precision Infrared Calibrators from Flukes
Hart Scientific division.

Offering a broad temperature covered by


three models you can easily cover varied
contact temperature probe workloads
between -25 C to 660 C.
They are quick to reach temperature set
points, yet they are stable, uniform, and
accurate. These industrial temperature
calibrators are perfect for performing
transmitter loop calibrations, comparison
calibrations, or simple checks of
thermocouple sensors.
Adding the process option means there is
no need to carry additional tools into the
field. The optional built-in two-channel
readout measures resistance, voltage, and
420 mA current with 24V loop power.
Fluke 4180/4181

Lightweight, portable, and fast


Cool to 25 C in 15 minutes and heat to
660 C in 15 minutes
Built-in two-channel readout for PRT,
RTD, thermocouple, 4-20 mA current
On-board automation and
documentation
Metrology performance in accuracy,
stability, uniformity, and loading

Included Accessories

914x: 9930 Interface-it Software, Report of


Calibration, Test leads (P Version Only),
6-pin DIN Connector for Reference Probe
(P Version Only)

Their accredited calibrations from Harts


IR laboratory help to ensure traceable,
consistent measurements accurate to
+0.25 C. Select from eight preconfigured
Fluke thermometer settings or set up your
own.
The large 152 mm (6 inch) target helps
eliminate errors. So whether youre
measuring from -15 C to 120 C (4180)
or from 35 C to 500 C (4181) youll get
a 4:1 TUR.
High performance, designed for
industrial use
Guaranteed accuracy specifications
Excellent stability and uniformity
Large 152 mm targets capture peripheral
vision of IR thermometer
Portability and speed for field use including convenient bail handle
Simulates individual IR thermometer
emissivity settings
No difficult infrared calculations
Fluke and Raytek thermometer
calibration points can be loaded directly
into the calibrator for convenience
Calibrated in accredited infrared
laboratory by Hart Scientific, the experts
in temperature calibration
At least 4 times more accurate than
most IR thermometers
Calibration includes uncertainties from
surface heat loss and emissivity

Ordering Information
Fluke 4180

Precision Infrared
Calibrator, 15 C to 120 C
Fluke 4181
Precision Infrared
Calibrator, 35 C to 500 C
Fluke 4180-CASE Carrying Case, 4180, 4181
Fluke 4180-DCAS Carrying Case with wheels,
4180, 4181
Fluke 9142-X
Fluke 9143-X
Fluke 9144-X

Field Metrology Well,


Low Temp
Field Metrology Well,
Mid Temp
Field Metrology Well,
High Temp

Add -P to order optional Process option


(914X-X-P). X represents insert type,
A, B, C, D, E or F

Specifications
9142

9143

9144

4180

4181

Temp Range

25 C to 150 C

33 C to 350 C

50 C to 660 C

15 C to 120 C

35 C to 500 C

Stability

0.01 C Full Range

0.2 C at 250 C

0.01 C Full Range

0.1 C at 0 C

0.1 C at 35 C

Target Size
diameter
Emissivity
Range
NIST
Accredited
Calibration

N/A

0.03 C at 50 C
0.04 C at 420 C
0.05 C at 660 C
0.02 C at 50 C
0.05 C at 420 C
0.15 C at 660 C
N/A

0.05 C at 0 C

Uniformity

0.02 C at 33 C
0.02 C at 200 C
0.03 C at 350 C
0.01 C at 33 C
0.015 C at 200 C
0.02 C at 350 C
N/A

152.4 mm

N/A

N/A

N/A

152.4 mm
diameter
Preset to 0.95

YES

YES

YES

YES

YES

9142/9143/9144:
Size (HxWxD): 290 x 185 x 295 mm
Weight: 9142: 8.2 kg, 9143: 7.3 kg, 9144: 7.7 kg
One Year Warranty

www.chorus.ro

Preset to 0.95

4180/4181
Size (HxWxD): 241 x 356 x 241 mm
Weight: 4180: 9.1 kg, 4181: 9.5 kg
One Year Warranty

For the complete line of Fluke heat sources


check the Fluke website

107

717/718/718Ex/719
Pressure Calibrators
Pump up the pressure

Fluke 719

Fluke 717

717 Pressure Calibrators

718 Pressure Calibrators

Measure pressure, 0.025% of full scale


with internal sensor
- 1/8 NPT pressure fitting
- Compatible with non-corrosive gasses
and liquids
Pressure measurement to 690 bar
Wide range of selectable measurement
units for pressure
Current measurement with 0.015%
accuracy and 0.001mA resolution
Simultaneous pressure and current
measurement for easy P/I testing
24 volt loop power supply
Zero, Min-Max, Hold and Damping
functions
Pressure switch test captures set, reset
and deadband values

Same features as Fluke 717 plus:


Newly designed built-in pressure/
vacuum hand pump with vernier and
bleed valve helps protect the pump from
damage and is easier to clean
For 718Ex Intrinsically Safe Pressure
Calibrator see chapter on Ex products in
this catalog.

719 Electric Pressure Calibrator


Same features as Fluke 717 plus:
Electric pump for one handed operation
mA source for calibrating I/P devices
and 4-20 mA I/O
Best in class pressure measurement
accuracy of 0.025%
Programmable pump limit settings can
eliminate overpressurization - set pump
to pressure values

Specications

Fluke 718Ex

Fluke 718

Included Accessories

Fluke 717, 718, 718Ex and 719:


Yellow Holster (718Ex red holster), Test leads,
AC172 Alligator Clips, Single 9V alkaline
battery (two 9V batteries in 718 and 719), User
manual on CD ROM.
719 also includes: Push fit connectors,
Translucent test hose.

Ordering Information
Fluke 719 30G
Fluke 719 100G
Fluke 718 1G
Fluke 718 30G
Fluke 718 100G
Fluke 718 300G
Fluke 718Ex 30G

108

Electric Pressure Calibrator


Electric Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
Intrinsically Safe Pressure
Calibrator
Fluke 718Ex 100G Intrinsically Safe Pressure
Calibrator
Fluke 717 1G
Pressure Calibrator
Fluke 717 15G
Pressure Calibrator
Fluke 717 30G
Pressure Calibrator
Fluke 717 100G
Pressure Calibrator
Fluke 717 300G
Pressure Calibrator
Fluke 717 500G
Pressure Calibrator
Fluke 717 1000G Pressure Calibrator
Fluke 717 1500G Pressure Calibrator
Fluke 717 3000G Pressure Calibrator
Fluke 717 5000G Pressure Calibrator
Fluke 717 10000G Pressure Calibrator

Model
719 30G
719 100G
718 1G
718 30G
718 100G
718 300G
717 1G
717 15G
717 30G
717 100G
717 300G
717 500G
717 1000G
717 1500G
717 3000G
717 5000G
717 10000G

Range
-850 mbar to 2 bar
-850 mbar to 7 bar
-68.9 mbar to 68.9 mbar
-850 mbar to 2 bar
-850 mbar to 7 bar
-850 mbar to 20 bar
-68.9 mbar to 68.9 mbar
-830 mbar to 1 bar
-850 mbar to 2 bar
-850 mbar to 7 bar
-850 mbar to 20 bar
0 mbar to 34.5 bar
0 mbar to 69 bar
0 bar to 103.4 bar
0 bar to 207 bar
0 bar to 345 bar
0 bar to 690 bar

Resolution
0.1 mbar
1 mbar
0.001 mbar
0.1 mbar
0.1 mbar
1 mbar
0.001 mbar
0.01 mbar
0.1 mbar
0.1 mbar
1 mbar
1 mbar
1 mbar
0.01 bar
0.01 bar
0.01 bar
0.01 bar

Over Pressure
Over pressure 2xFS
Over Pressure 2xFS
Over Pressure 5xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 375 PSI, 25 bar
Over Pressure 5xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 375 PSI, 25 bar
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS
Over Pressure 2xFS

For Fluke 717/718/719 models: Supported Pressure Units; psi, in. H2O(4C), in. H2O(20C), cm
H2O(4C), cm H2O(20C), bar mBar, kPa, inHg, mmHg, kg/cm2
Functions: Zero, Min, Max, Hold, Damp functions
Max. Voltage: 30 V
Operating temperature: -10C to 55C
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 717: For use with non corrosive gasses and liquids
Fluke 718/719: For use with Dry Air only
717
Size (HxWxD): 201 mm x 98 mm x 52 mm
Weight: 0.6 kg
Three years Warranty

719
Size (HxWxD): 210 mm x 87 mm x 60 mm
Weight: 0.912 kg
Three Year Warranty (Pump one year)

718/718Ex
Size (HxWxD): 216 mm x 94 mm x 66 mm
Weight: 0.992 kg
Warranty: Three years (Pump one year)

Recommended Accessories
(Not for hazardous zones)

www.chorus.ro
C43 (718)
See page 130

C125 (717)
See page 130

TL220-1
See page 122

700P27
See page 112

700 LTP-1
See page 112

705/707/707Ex/715
Loop Calibrators
4-20 mA, source, measure, simulate
705 Loop Calibrator

715 Volt/mA Calibrator

Simultaneous mA and %
mA accuracy of 0.02%
Measure, source and simulate mA
Push button 25% steps for fast, easy
linearity checks
Span Check for fast confirmation of
zero and span
Selectable slow ramp, fast ramp, and
step function
24 volt internal loop supply
0 - 20 mA or 4 - 20 mA default start up
modes

Measure loop current (0-20 mA,


4-20 mA) signals with 0.015% accuracy
and 0.001 mA resolution
Measure voltage output process signals
from PLCs, transmitters
Source or simulate 24 mA loop current
Source voltage to 100 mV or 10 V
24 V loop supply with simultaneous
current measurement

707 Loop Calibrator

Fluke 705

Fluke 715

Features of the Fluke 705


Quick Click detented rotary knob for
one handed operation
Higher accuracy: 0.015%
Mains Voltage Input protection
250 Ohm loop resistance for with Hart
instrumentation

707Ex Intrinsically Safe Loop


Calibrator
Same features as Fluke 707
For use in explosion endangered areas
ATEX certified ( II 2 G Eex ia IIC T4)

Specications
Functions
Voltage measurement
Range
Resolution
Accuracy

Current measurement
Range
Resolution
Accuracy
Fluke 707

Current sourcing
Range
Accuracy
Drive capability
Fluke 707Ex
Loop power while measuring mA
Voltage sourcing
Display current and % of span
Auto step, auto ramp
Span Check
1

705/707/707 Ex

715

0-28 V DC
1 mV
705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD

0-200 mV, 0-20 V


10 V 1 mV
0.01% Rdg + 2 LSD

0-24 mA
0.001 mA
705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD

0-24 mA
0.001 mA
0.015%

0-20 mA or 4-20 mA1


705: 0.025% Rdg + 2 LSD
707/707Ex: 0.015% Rdg + 2 LSD
705: 1000 @ 24 mA
707: 1200 @ 24 mA
707Ex: 700 20 mA
24 V
N/A
Yes
Yes
Yes

0-20 mA or 4-20 mA1


0.015% + 2 LSD
1000 @ 24 mA
24 V
0-100 mV or 0-10 V
mA or %
Yes
Yes

will over-range to 24 mA

Included Accessories
Fluke 705/707: C10 Yellow Holster, Test Leads,
AC172 Alligator Clips, Single 9V alkaline
battery, Instruction Sheet
Fluke 707Ex: Red Ex-holster, Test Leads, AC172
Alligator Clips, Single 9V alkaline battery,
Instruction Sheet
Fluke 715: Yellow Holster (H80M excl. TPAK),
Test Leads and AC172 Alligator Clips, Single 9V
alkaline battery, Instruction Sheet

Fluke 705, 707, 707Ex

Maximum voltage: 30 V (28 V - 707Ex)


Operating temperature: -10 to 55C
Safety: CSA C22.2 No. 1010.1: 1992
EMC: EN50082-1:1992 and EN55022: 1994 Class B
Size (HxWxD): 164 mm x 75 mm x 47 mm;
Weight: 0.35 kg
Battery: One 9 V alkaline
Battery life: 18 hours typical, at 12 mA
Three Year Warranty

715

Size (HxWxD): 201 mm x 98 mm x 52 mm


Weight: 0.6 kg
Battery: One 9V alkaline
Battery life: 4 to 20 hours
Three Year Warranty

Ordering Information
Fluke 705
Fluke 707
Fluke 707Ex
Fluke 715

Loop Calibrator
Loop Calibrator
Intrinsically Safe Loop Calibrator
Volt/mA Calibrator

www.chorus.ro
C12A (705/707)
See page 130

C25 (715)
See page 130

TL220-1
See page 122

TP920
See page 121

T PAK (715)
See page 132

109

771, 772 and 773


mA Process Clamp Meters
mA measurements without breaking the loop.
Save time. Save money.
Fluke 771, 772 and 773

Fluke 773

Measure 4 to 20 mA signals without


breaking the Loop, save time and
money troubleshooting 4 to 20 mA
signals

DC voltage measurement to verify 24 V


power supplies or voltage I/O signals
Source dc voltage to test voltage input
devices
Scaled mA output signal enables a
logging DMM (289) to record 4 to 20 mA
signal without breaking the loop
mA in/out: simultaneously source a mA
signal while measuring a mA signal
with the clamp

Fluke 772 and 773


Source 4 to 20 mA signals for testing
control system I/O or I/Ps
Simulate 4 to 20 mA signals for testing
control system I/O
Measure 4 to 20 mA signals with incircuit measurement
Power a transmitter with the 24 V loop
power supply
Automatically ramp and step change
the 4 to 20 mA output for remote
testing

Fluke 771

Features

Fluke 772

771
O

mA measure w/jaw
mA measure In circuit
mA source
mA sim
Loop power 24 V
DCV source 0-10 V
DCV measure 0-30 V
Scaled mA output to mA input
mA in/out

771, 772, 773


772 and 773

Fluke 771: soft carrying case and users manual


Fluke 771 + 772: plus test leads, AC172 alligator
clip set and TL940 mini-hook test lead set

773
O
O
O
O
O
O
O
O
O

Specifications

Fluke 773

Included Accessories

772
O
O
O
O
O

Function
mA measurement

Resolution and range


0 to 20.99 mA
21.0 mA to 100.0 mA

Accuracy
0.2 % + 5 counts
1 % + 5 counts

mA measurement

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA source

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA simulate

0 to 24.00 mA

0.2 % + 2 counts

773

Voltage source

0 to 10.00 V dc

0.2 % + 2 counts

773

Voltage measure

0 to 30.00 V dc

0.2 % + 2 counts

Notes
Measured by clamp
Measured in series
with test jacks
Maximum mA drive:
24 mA into 1,000 ohms
Maximum voltage
50 V dc
2 mA maximum
drive current

Ordering Information
Fluke 771
Fluke 772
Fluke 773

110

Milliamp Process Clamp Meter


Milliamp Process Clamp Meter
Milliamp Process Clamp Meter

Size (HxWxD):
771: 212 mm x 59 mm x 38 mm
772 + 773: 248 mm x 76 mm x 41 mm
Weight: 771: 0.26 kg
772 + 773: 0.42 kg
Battery: 771: 2x 1.5V Alkaline, IEC LR6
772 + 773: 4x 1.5V Alkaline, IEC LR6

www.chorus.ro

Battery Life: 771: 20 hours typical


772 + 773: 12 hours @ 12 mA source into
500 ohms
IP Rating: IP 40
Warranty: 3 years, 1 year on mA clamp
accessory and cable

787/789 ProcessMeters
Double your power
The Fluke 787 and 789 ProcessMeters
combine a Digital Multimeter and a Loop
Calibrator in one rugged handheld tool,
giving process technicians double the
power.
The Fluke 789 has a built-in 24 V loop
supply which reduces the need for
taking a separate power supply when
doing offline transmitter testing. The
IR communication port of the Fluke
789 allows data to be logged to optional

FlukeView Software for graphical analysis


and reporting.

Features

Fluke 787

Fluke 789

787
O
O
O

DMM and Loop Calibrator in one tool


Precision 1000 V, 440 mA True RMS Digital Multimeter
DC current source and Loop Calibrator
24 V Loop power supply
Min/Max / Average / Hold / Relative Modes
Diode Test and Continuity Beeper
Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
Simultaneous mA and % of scale read-out
Externally accessible battery / fuses
HART mode setting with loop power and a built-in 250 resistor
0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check
Infrared I/O serial port

O
O
O
O
O/-

789
O
O
O
O
O
O
O
O
O/O
O
O
O

Specifications
787

True RMS

Included Accessories
787: Yellow Holster (H80M excl. TPAK), Hard
Point Test Lead Set plus AC172 Alligator Clips,
one 9V battery, user manual
789: Test Lead Set plus AC172 Alligator Clips,
four 9V AA alkaline batteries, user manual
and quick reference guide.

Ordering Information
Fluke 787
Fluke 789
FVF-SC2

ProcessMeter
ProcessMeter
FlukeView Forms Software
including interface cable

Voltage measurements
Range
Resolution
Accuracy
Current measurement
Range
Resolution
Accuracy
Current Sourcing
Range
Accuracy
Other specifications
Max drive capability
Loop power
Resistance measurement
Frequency
Continuity
Span Check

789

0-1000 V AC or DC
0.1 mV to 1.0 V
0.1% Rdg+1 LSD (V DC)

0-1000 V AC or DC
0.1 mV to 1.0 V
0.1% Rdg+1 LSD (V DC)

0-1 A
1 mA
0.2%+2 LSD

0-1 A
1 mA
0.2%+2 LSD

0-30 mA
0.001 mA
0.05%+2 LSD

0-30 mA
0.001 mA
0.05%+2 LSD

0-20 mA or 4-24 mA
0.05% of span

0-20 mA or 4-24 mA
0.05% of span

500
N/A
To 40 M, 0.2%+1 LSD
To 19.999 kHz, 0.005%+1 LSD
Beeps for resistance < 100
No

1200
24 V
To 40 M, 0.2%+1 LSD
To 19.999 kHz, 0.005%+ LSD
Beeps for resistance < 100
Yes

Maximum voltage: 1000 V


Operating temperature: -20 to 55C

787

Size (HxWxD): 201 mm x 98 mm x 52 mm


Weight: 0.642 kg
Battery: One 9 V alkaline
Battery life: 12 to 50 hours typical
Three Year Warranty

789

Size (HxWxD): 203 mm x 100 mm x 50 mm


Weight: 0.6 kg
Battery: Four AA alkaline batteries
Battery life: 14 to 140 hours typical
Three Year Warranty

Recommended Accessories

www.chorus.ro
C125
See page 130

TL220-1
See page 122

80T-150U
See page 128

i400
See page 126

i410
See page 127

111

Field Calibrator Accessories


Fluke 700 Series Pressure Modules
Ranges from 2.5 mbar to 700 bar.
Gage, differential, dual (compound), absolute
and vacuum modules
Very high accuracy: up to 0.025% FS
Features internal temperature compensation
from 0C to 50C for full-accuracy
performance
Pressure readings update twice per second,
and may be displayed in any of 11 different
units
Model
Differential
700P00
700P01/700P01Ex
700P02
700P22
700P03
700P23
700P04
700P24/700P24Ex
Gage
700P05/700P05Ex
700P06/700P06Ex
700P27/700P27Ex
700P07
700P08
700P09/700P09Ex
Absolute
700PA3
700PA4/700PA4Ex
700PA5
700PA6
Vacuum
700PV3
700PV4
Dual
700PD2
700PD3
700PD4
700PD5
700PD6
700PD7
High
700P29/700P29Ex
700P30
700P31

Compatible with Fluke 717, 718, 725 and 75x


series.
Rugged cases protect the modules from
harsh environments
All modules include NIST traceable
certificate and test data
ATEX certified Ex versions available
(
II 1 Eex ia IIB T4)

Range (approx.)

Resolution
uncertainty
(23 3C) (FS)

Reference

High side media

Low side media

Fitting material

Max
overpressure2)

2.5 mbar
25 mbar
70 mbar
70 mbar
340 mbar
340 mbar
1000 mbar
1001 mbar

0.001 mbar
0.01 mbar
0.007 mbar
0.007 mbar
0.01 mbar
0.01 mbar
0.1 mbar
0.1 mbar

0.3 %
0.2 %
0.15 %
0.1 %
0.05 %
0.025 %
0.025 %
0.025 %

Dry 1)
Dry
Dry
316 SS
Dry
316 SS
Dry
316 SS

Dry 1)
Dry
Dry
Dry
Dry
Dry
Dry
Dry

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

30x
3x
3x
3x
3x
3x
3x
3x

2 bar
7 bar
20 bar
34 bar
70 bar
100 bar

0.1 mbar
0.7 mbar
1 mbar
1 mbar
7 mbar
10 mbar

0.025 %
0.025 %
0.025 %
0.025 %
0.025 %
0.025 %

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

N/A
N/A
N/A
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x
3x
2x

340 mbar
1000 mbar
2 bar
7 bar

0.01 mbar
0.1 mbar
0.1 mbar
0.7 mbar

0.05 %
0.05 %
0.05 %
0.05 %

316 SS
316 SS
316 SS
316 SS

N/A
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x

-340 mbar
-1000 mbar

0.01 mbar
0.1 mbar

0.04 %
0.04 %

316 SS
316 SS

Dry
Dry

316 SS
316 SS

3x
3x

70 mbar
340 mbar
1000 mbar
-1000/+2000 mbar
-1000 mbar/+6.9 bar
-1000 mbar/+13.8 bar

0.007 mbar
0.01 mbar
0.1 mbar
0.1 mbar
1 mbar
1 mbar

0.15 %
0.04 %
0.025 %
0.025 %
0.025 %
0.04 %

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

Dry
Dry
Dry
N/A
N/A
N/A

316 SS
316 SS
316 SS
316 SS
316 SS
316 SS

3x
3x
3x
3x
3x
3x

200 bar
340 bar
700 bar

0.01 bar
0.01 bar
0.07 bar

0.05 %
0.05 %
0.05 %

C276
C276
C276

N/A
N/A
N/A

C276
C276
C276

2x
2x
1.5x

1)Dry indicates dry air or non-corrosive gas as compatible media. 316 S S indicates media compatible with Type 316 Stainless Steel. C276 indicates media compatible with Hastelloy C276.
2)Maximum overpressure specification includes common mode pressure.

Other accessories
700LTP-1 Low-pressure Test Pump

700PRV-1 Pressure Relief Valve

For low pressure applications


Vacuum to -13 psi / -.90 bar
Pressure to 100 psi / 6.9 bar
With fine-control, adjustable relief valve
and slow bleed capability

Pressure relief valve for 700HTP-1


Adjustable from 725 to 5800 PSI
(50 to 200 bar)

700PTP-1 Pneumatic Test Pump-1

112

700ILF In-Line Filter for the


Fluke 718

700HTP-2 Hydraulic Test Pump

700PCK Pressure Module


Calibration Kit

www.chorus.ro
Fluke 700LTP-1

Fluke 700PTP-1

Hydraulic test hose is a 10,000 psi, 690 bar

Handheld pressure pump


Pressures up to 600 psi, 40 bar
Pressures up to 10,000 psi/690 bar.

Fluke 700HTP-2

700HTH-1 Hydraulic Test Hose

BE9005 Battery Eliminator

Vibration Tester
With the Fluke 810 Vibration Tester you will be able to control unplanned
downtime, prevent recurring problems, set repair priorities and manage
your resources with an entirely new approach to vibration testing. In three
quick, easy steps, the new Fluke 810 helps you locate and diagnose common mechanical problems and prioritize their repair actions. The combination of powerful algorithms and a database of real-world measurement
experience make the Fluke 810 the most advanced troubleshooting tool
for mechanical maintenance teams who need an answer now.

www.chorus.ro

113

810 Vibration Tester


Motor diagnosis and repair in three simple steps
The Fluke 810 Vibration Tester is the
most advanced troubleshooting tool
for mechanical maintenance teams
who need an answer now. The unique
diagnostic technology helps you quickly
identify and prioritize mechanical
problems, putting the expertise of a
vibration analyst in your hands.

Use the vibration tester to:

Fluke 810

Set-up

Troubleshoot problem equipment and


understand the root cause of failure
Survey equipment before and after
planned maintenance and confirm the
repair
Commission new equipment and
ensure proper installation
Provide quantifiable proof of equipment
condition and drive investment in
repair or replacement
Prioritize and plan repair activities and
operate more efficiently
Anticipate equipment failures before
they happen and take control of spare
parts inventories
Train new or less-experienced
technicians and build confidence and
skill across the team

Measure

Features and benefits


On-board identification and location of
the most common mechanical faults
(bearings, misalignment, unbalance,
looseness) focus maintenance efforts
on root cause, reducing unplanned
downtime
Fault severity scale with four severity
levels help you prioritize maintenance
work
Repair recommendations advise
technicians on corrective action
On-board context sensitive help provide
real-time tips and guidance to new
users
2 GB expandable on-board memory
provide enough space for your
machinerys data
Self-test functions ensure optimal
performance and more time on the job
Laser tachometer for accurate machine
running speed promotes confident
diagnoses
Tri-axial accelerometer reduces
measurement time by 2/3 over single
axis accelerometers
Viewer PC Software expands data
storage and tracking capacity
Color LCD display and intuitive
multilingual, icon-based user interface
promote use right out of the box

Specifications
(Check the Fluke web for detailed specifications)

Diagnose

Language support:
eng, ger, fre, ita, spa, por

Included Accessories
Tri-axial TEDS accelerometer, accelerometer
magnet mount, accelerometer mounting
pad kit with adhesive, accelerometer quick
disconnect cable, laser tachometer and
storage pouch, smart battery pack with cable
and adapters, shoulder strap, adjustable
hand strap, Viewer PC application software,
mini-USB to USB cable, getting started guide,
illustrated quick reference guide, users
manual CD-ROM, instructional training CDROM, hard carrying case.

www.chorus.ro
Ordering Information

114

Diagnostic specifications
Standard faults
Unbalance, looseness, misalignment and bearing failures
Analysis for
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps,
piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/
lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed
coupled machines, spindles
Machine rotational
200 rpm to 12000 rpm
speed range
Diagnosis details
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details,
cited peaks, spectra
Electrical specifications
Ranging
Automatic
A/D converter
4 channel, 24 bit
Usable bandwith
2 Hz to 20 kHz
Sampling
51.2 kHz
Digital signal
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping,
processing functions windowing, FFT, and averaging
Sampling rate
2.5 kHz to 50 kHz
Dynamic range
128 dB
Amplitude accuracy
0.1 dBV
FFT resolution
800 lines
Spectral windows
Hanning
Frequency units
Hz, orders, cpm
Amplitude units
in/sec, mm/sec, VdB (US), VdB (Europe)
Non-volatile nemory SD micro memory card, 2 GB internal + user accessible slot for additional storage

Fluke 810

Vibration Tester

Battery type: Lithium-ion, 14.8 V 2.55 Ah


Size (HxWxD): 186 x 267 x 70
Weight: 1.9 kg

Warranty: Three years on tester


One year on sensor and tachometer

481 Radiation Detection Meter


Radiation safety quality assurance is top of mind for hospitals, nuclear
power facilities, nuclear medicine laboratories, x-ray manufacturers,
government agencies, state inspectors, emergency response and
HAZMAT (hazardous materials) teams, and police and fire departments
around the world.
With the 481 Fluke offers these professionals the versatility they need to
get the job done and the quality they trust in a radiation-safety device.

www.chorus.ro

115

481 Radiation Detection Meter


Fluke 481 Radiation Detection Meter
The Fluke 481 Radiation Detection Meter
is a portable and practical means for
discovering irradiated goods, and for
helping remediate contaminant and
safety issues while minimally affecting
performances. Ideal for detecting
irradiated goods, equipment, surfaces
or environments in industrial settings,
the 481 Radiation Meter helps ascertain
worker safety and compliance to national
regulations.

Fluke 481

Use of the Fluke 481 assures employees


that radiation dangers are known,
monitored and calculated for their
security. Whenever radiation is found,
a clear and quantifiable result provides
handlers to comply with national
guidelines while avoiding unnecessary
steps that could stop procedures, impact
productivity or lead to missed revenue.
Detects skin-dose (beta particle)
and deep-dose (gamma) and X-ray
radioactivity

Requires no adjustments; simple two


button process
Provides promptly read, correct value
through autoranging capability
Easily visible inside truck trailers
and other low-light situations with
automated backlight
Works dependably inside or outside
thanks to sealed case
30 % more precise than other available
meters
Delivers more than one week of
uninterrupted functioning with two
9-volt alkaline batteries
Proven in use by state and local
governmental emergency response
professionals, state inspectors,
HAZMAT teams and nuclear power
workers
Measures both dose and dose-rate
Valuable for contamination-detection,
general radiation area metering,
radiation-level monitoring, and
hazardous materials assessment
Rugged Fluke design

Specications
General specifications
Radiation detected

Fluke 481
Beta > 100 keV
Gamma > 7 keV

Fluke 481-DESI

Operating ranges

0 mR/h to 5 mR/h (8 sec)


0 mR/h to 50 mR/h (2.5 sec)
0 mR/h to 500 mR/h (2 sec)
0 R/h to 5 R/h (2 sec)
0 R/h to 50 R/h (2 sec)

Accuracy

Within 10 % of readings between 10 % and 100 % of full scale indication on any


range, exclusive of energy response

Detector

Chamber (cc volume air ionization) 349 cc


Chamber wall (phenolic) 246 mg/cm2
Chamber window (mylar) 6.6 mg/cm2
Beta slide 440 mg/cm2

Automatic features
Power requirements
Warm-up time
Battery life

Auto-zeroing, auto-ranging, and auto-backlight


Two 9 V alkaline, 200 hours operation
One minute
Four+ hours continuous use per battery pack
(assumes 50 % brightness of LCD)

0 Sv/h to 50 Sv/h (8 sec)


0 Sv/h to 500 Sv/h (2,5 sec)
0 mSv/h to 5 mSv/h (2 sec)
0 mSv/h to 50 mSv/h (2 sec)
0 mSv/h to 500 mSv/h (2 sec)

Dimensions (W x D x H)
10 cm x 20 cm x 15 cm
Weight
1.11 kg
Display LCD analog/digital with backlight
Analog
100 element bar graph 6.4 cm long. Bar graph is divided into 5 major segments,
each labeled with the appropriate value for the range of the instrument

Ordering Information

Digital

190HPS

Modes
Integrate mode

Fluke 481
Fluke 481-DESI

Ion Chamber Survey Meter


DESI Ion Chamber Survey Meter,
dose equivalent SI
Single Unit Carrying Case

Freeze mode

www.chorus.ro
Environmental
Temperature range
Relative humidity
Geotropism

116

2.5 digit display is followed by a significant zero digit depending on the


operating range of the instrument. The units of measurement are indicated
on the display at all times. Digits are 6.4 mm high. Low battery and freeze
indicators are also provided on the display

Operates continuously 30 seconds after the instrument has been turned on.
Integration is performed even if the instrument is displaying in mR/h or R/h
Will place a tick mark on the bar graph display to hold on the peak displayed
value. The unit will continue to read and display current radiation values

-20 C to 50 C
0 % to 100 % (at 50 C)
<1%

ATEX Certified Test Tools


The Fluke line of intrinsically safe tools is designed to meet the needs of
technicians working in and around hazardous areas. The tools are ideal
for environments in chemical plants, petro-chemical plants, oil platforms, refineries and other locations where risk of explosion exists. The
products are easily recognizable from standard Fluke products by their
lighter grey colour and red holster.

www.chorus.ro

117

A brief look at ATEX


Intrinsic safety is a protection standard
employed in potentially explosive
atmospheres. Devices that are certified
as intrinsically safe are designed to be
unable to release sufficient energy, by
either thermal or electrical means, to cause
ignition of flammable material (gas, dust/
particulates).

What is Intrinsically Safe?


Intrinsically safe standards apply to all
equipment that can create one or more
of a range of defined potential explosion
sources:
Electrical sparks
Electrical arcs
Flames
Hot surfaces
Static electricity
Electromagnetic radiation
Chemical reactions
Mechanical impact
Mechanical friction
Compression ignition
Acoustic energy
Ionizing radiation

What industries are intrinsically


safe products designed for?
Petro-chemical
Oil platforms and refineries
Pharmaceutical
Bulk materials (e.g. grain)
Mining
Pipelines
Any environment where explosive gases
are present

What is ATEX?
The primary intrinsically safe standard has
been set in the European Union with the
9/94/EC Directive, commonly called ATEX
(Atmosphres Explosibles, French for
explosive atmospheres). The stated goal of
the guidelines is to help ensure the free
movement of products in the European
Union by minimizing the number of
safeguard clause applications, at least those
originating from divergent interpretations
The ATEX rules have been in place as a
voluntary standard since 1 March 1996.
The rules are mandatory on electrical
and electronic equipment for use in
environments subject to explosion hazard
sold in the EU starting 1 July 2003. From

this date onwards, all products sold for


use in explosive atmospheres must have
ATEX certification and carry the distinctive
symbol:

The Fluke Ex (IS) product line


Fluke is among the first manufacturers to
produce handheld test tools according to
the latest ATEX standards. The Fluke line of
intrinsically safe tools is designed to meet
the needs of technicians working in and
around hazardous areas:
Install, maintain and troubleshoot
equipment by using the new Fluke 87V Ex
Digital Multimeter
Maintain and calibrate sensors,
transmitters and control loops with the
line of Ex field calibrators
The tools are ideal for environments
in petro-chemical plants, oil platforms,
refineries and other locations subject to risk
of explosion.
Apart from having the ATEX markings, the
visual difference between a standard Fluke
tool and the corresponding Ex version is
the different grey body colour and a red,
conductive holster designed specifically
to eliminate the potential for electrical
discharge.
Inside, the Fluke Ex tools have been
reengineered to reduce energy avoiding
generation of heat and electrical sparks.
They are premium products designed for
ultimate safety.
Making sense of ATEX certification
Fluke 707Ex is ATEX-compliant and is
certified
II 2 G EEx ia IIC T4 but what
exactly does that mean?

Here a brief explanation of the ATEX


certification designations.

ATEX certification 707Ex

II 2 G

EEx
ia
IIC
T4

118

The ATEX examination mark. This sign is required on all devices used in European hazardous
areas.
The classification of zones.
II designates the tool is approved for all non-mining areas.
2 represents the category of the device, in this case the device is rated for the second most
hazardous areas.
G designates atmosphere, in this case gas, vapors and mist.
Explosion protection based on European Ex-regulations.
The type of protection from explosion, in this case the energy in a device or connector has
been reduced to a safe value.
Gas Group. IIC indicates compatibility with the most dangerous gas group.
Temperature class gives the user the maximum temperature of a surface that may be in
contact to the Ex atmosphere under fault conditions. T4 is rated at 135C.

www.chorus.ro

ATEX-certified Test Tools


Fluke intrinsically safe tools for tough measurement and
calibration tasks

Fluke 87V Ex Intrinsically safe


version of the worlds most popular
multimeter

Fluke 87V Ex

With its high performance, accuracy and


motor drive compatibility, the Fluke 87V
is the most popular industrial multimeter
around. Now Fluke has introduced a new
intrinsically safe version the 87V Ex for
measurements in and around hazardous
areas.
The Fluke 87V Ex has all the measurement
and troubleshooting functions of the proven
Fluke 87V. Unlike other ATEX-certified tools,
it can be used both inside and outside the
hazardous zone (ATEX Zones 1 & 2) without
compromising performance or compliance.
So theres no need to carry different tools
for use in specific zones. It also has a builtin thermometer with TC probe, further
reducing technicians tool counts.
ATEX safety rating II 2G EEx ia IIC T4
EN61010-1 CAT III 1000V/CAT IV 600V
electrical safety rating

Fluke 707Ex Fast, one-handed tool for


loop checks
The Fluke 707Ex is the ideal, stand alone
tool for calibration and maintenance of 4
to 20 mA control loops. It provides 24V loop
power while measuring mA, and lets you
measure and source/simulate mA with 1 A
resolution.
ATEX safety rating
II 2G EEx ia IIC T4
See also page 109

Fluke 707Ex

Fluke 718Ex Self-contained Pressure


Calibrator
The Fluke 718Ex offers a convenient,
self contained solution for pressure
measurements and calibration. With its
internal pressure sensor and pump, its
ready for immediate, stand alone use. The
pressure range can easily be extended to up
to 200 bar with any of the 8 Fluke 700PEx
Pressure Modules.
ATEX safety rating
II IG EEx ia IIC T4

See also page 15

Fluke 725Ex Intrinsically safe


Multifunction Process Calibrator
The Fluke 725Ex intrinsically safe
Multifunction Process Calibrator is powerful
yet easy-to-use. Combined with the
Fluke 700PEx Pressure Modules, the 725Ex
is able to calibrate almost any process
instrument likely to need service in any
area where explosive gases may be present.
ATEX safety rating
II IG EEx ia IIB 171C
Fluke 725Ex

See also page 104

See also page 108

Fluke 718Ex

1551A Ex and 1552A Ex Stik


Thermometer

1551A Ex/1552 Ex

Finally, a digital substitute for your


mercury-in-glass thermometers!
Accurate and repeatable to 0.05 C
over its full range, the 1551A/1552A
Stik Thermometer is the new gold
standard of industrial temperature
calibration. Whether working outdoors in
environments where potentially explosive
gases may be present or on the floor of
a processing plant, the intrinsically-safe,
battery operated, portable reference
thermometer is designed to go where you
work.
ATEX and IECEx compliant

www.chorus.ro

Fluke 700Ex Pressure Modules


These intrinsically safe pressure
modules for use with the Fluke 725Ex
Multifunctional Process Calibrator and
Fluke 718Ex Pressure Calibrator cover the
most commonly used pressure calibration
ranges from 0-25 mbar and 0-200 bar.
Theres a choice of 8 gage, differential and
absolute modules.
ATEX safety rating
II 1G EEx ia IIC T4
Fluke 700Ex

See also page 112

See also page 57

119

General Accessories
The best test tools deserve accessories designed and manufactured
to the same high quality and safety standards. So we also provide a
comprehensive range of test leads, probes and clips, current clamps,
temperature accessories and dedicated electronic and automotive
accessories. And to protect your valuable instrument, choose a rugged
Fluke tailor-made holster or case.

120

www.chorus.ro

Electronic Test Leads,


Probes & Clips

Test Leads

Test Leads / Patch Cords

TL910 Electronic Test Lead Set

TL960 Micro-Hook Test Lead Set

TP920 Test Probe Adapter Kit

Very small 1 mm tips to access hard


to reach test points
Probe tip length up to
100 mm, test lead length:
1m
Included: 3 sets of
spring loaded gold tips
and 2 sets of stainless steel tips
CAT II 1000 V, 3 A rating

1 pair (red, black) of test leads with


multi-stacking 4 mm banana
plugs and micro-hooks
Micro-hooks attach to
component leads up to 1 mm
diameter
90 cm long PVC insulated leads
30 V rms or 60 V DC, 15 A

Set of push-on adapters for TL71 and TL75


test probes
IC test adapters,
extended probe tips,
medium alligator
clips (max.opening
7.6 mm)
CAT I 300 V, 5 A rating

TL930 Patch Cord Set (60 cm)

TL970 Hook and Pincer Kit

1 pair (red, black)


multi-stacking 4 mm banana plug
patch cords
Nickel-plated banana
plugs
61 cm long
PVC insulated leads
30 V rms or 60 V DC, 15 A

TL940 Mini-Hook Test Lead Set


TL950 Mini-Pincer Test Lead
Set
TL960 Micro-Hook Test Lead
Set

TP912 Replacement Tips for TL910


Replacement tips for TL910
Five sets of gold plated and stainless
steel tips

TL40 Retractable Tip Test Lead Set


One pair (red, black) of test leads with
sharp needle point tips adjustable
to desired length from 0 to
76 mm
Extra hard probe tips
to provide long service life
Flexible silicone insulated test
leads
CAT II 150 V, 3 A rating, UL listed

TL932 Patch Cord Set (90 cm)


1 pair (red, black) multi-stacking 4 mm
banana plug patch cords
Nickel-plated banana
plugs
90 cm long
PVC insulated leads
30 V rms or 60 V DC, 15 A

TL935 Patch Cord Kit


(60, 90, 120 cm)
TL940 Mini-Hook Test Lead Set
1 pair (red, black) of test leads with multistacking 4 mm banana plugs and
mini-hooks
Mini-hooks attach to
component leads up to
1.5 mm diameter
90 cm long PVC
insulated leads
30 V rms or 60 V DC, 15 A

TL950 Mini-Pincer Test Lead Set


1 pair (red, black) of test leads with
multi-stacking 4 mm banana plugs
and mini-pincers
Mini-pincers open to
2.3 mm
90 cm long PVC insulated
leads
30 V rms or 60 V DC, 15 A

3 sets (red and black pairs) of


multi-stacking 4 mm banana
plug patch cords
Nickel-plated banana plugs
60 cm, 90 cm, 120 cm long PVC
insulated leads
30 V rms or 60 V DC, 15 A

Kits
TL80A-1 Basic Electronic Test Lead Kit
One pair (red, black) each 1 meter long
silicone test lead set,
alligator clip and probe
tip extender.
C75 soft carrying case
CAT II 300 V. UL listed

www.chorus.ro

TL81A Deluxe Electronic Test Lead Kit


Includes components of TL80, plus one pair
(red, black) each
modular 1 meter
long silicone test
lead, test probe,
hook-style and
pinch style clip,
alligator clip, IC
probe tip adapter
and spade lugs
Quadfold soft
carrying case
CAT II 300 V. UL listed

TLK287 Electronic Master Test Lead Kit


Includes modular leads, probes (black and
red), minigrabber/jack
set, medium alligator
clips (black and red),
spade lug/banana jack
plated (set), couplers
IEC1010 (black and red),
micrograbbers and
-leads (black and red)
TL910 Electronic Test
Lead Set
Quadfold Pouch
CAT III 1000 V (probes only)

BP980 Double Banana


Plug Kit
5 pair (red, black) of
double
4 mm banana plugs
Each plug has
3.1 mm holes for
mounting wires and
components
Brass plugs/jack, beryllium copper springs
30 V rms or 60 V DC, 15 A

121

Industrial Test Leads,


Probes & Clips

Test Leads

Modular Test Leads

Kits

TL71-1 Premium Test Lead Set

TL221 SureGrip
Extension Lead Set

TL220-1 SureGrip
Industrial Test Lead Kit

One pair (red, black) of silicone


insulated leads with straight
connectors on both ends
Reinforced strain relief
Includes one pair (red, black)
of female couplers
Extends test leads by 1.5 m
600 V CAT IV, 1000 V CAT III,
10 A rating. UL listed

AC220 SureGrip
Alligator Clip Set
TP238 SureGrip
Insulated Test Probe Set
TL222 SureGrip
Silicone Test Lead Set
(right to right)

TL222 SureGrip
Silicone Test Lead Set

TL223-1 SureGrip
Electrical Test Lead Kit

DMM test leads (red, black)


with safety shrouded, standard
diameter banana plugs
Right angle connector on
both ends
Reinforced strain relief
1.5 meter silicone-insulated
wire resists heat & cold
CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed

AC220 SureGrip
Alligator Clip Set
TP238 SureGrip
Insulated Test Probe Set
TL224 SureGrip Silicone
Test Lead Set (straight to
right)

One pair (red, black) comfort grip probes


with silicone insulated, right-angle
test leads
Recommended for V
measurements
CAT II 1000 V,
10 A rating. UL listed

TL75-1 Hard Point Test Lead Set


One pair (red, black) comfort grip probes
with PVC insulated, test leads with
right-angle shrouded banana
plugs
Recommended for
general purpose
measurements
CAT II 1000 V,
10 A rating. UL listed

TL76 All-in-one Test Lead Set


One pair (red, black) 1.5 meter long
silicone test leads with right
angle shrouded banana plug
Lantern tip (removable)
for use with European
wall sockets (4 mm )
Lantern tip can be removed
for easy access to terminal
blocks (2 mm )
Removable, insulated IC caps allow probing
on closely spaced leads and compliance with
GS38.
Cat IV 600 V, CAT III 1000 V, 10 A rating,
UL listed

TL224 SureGrip
Silicone Test Lead Set
DMM test leads (red, black)
with safety shrouded,
standard diameter banana
plugs
Right angle connector on one end and
straight connector on the other
Reinforced strain relief
1.5 meter silicone-insulated wire resists
heat & cold
CAT IV 600 V, CAT III 1000 V, 10 A rating.
UL listed

TL27 Heavy Duty


Test Lead Set
DMM test leads (red, black)
with safety shrouded,
standard diameter banana
plugs
Heavy duty EPDM insulation
Length 1.5 m
CAT III 1000V, 10A rating.
UL listed

H900 Test Lead


Holder

SureGrip accessories are designed to


improve steadiness in slippery hands.
Rubber overmolded surfaces and fingerhugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.

122

Heavy duty
construction with
mounting holes
Holder has 10 slots for wires up to
8 mm in diameter
Over-all dimensions: 27.9 cm
L x 8.9 cm W x 3.2 cm H

www.chorus.ro

TL238 SureGrip High


Energy Test Lead Kit
TP238 SureGrip Insulated Tip Test
Probes with less than 4 mm of
exposed metal (GS38) with
flexible removable finger
banner
TP280 20 cm Test Probe
Extenders
TL224 SureGrip Silicone
Test Lead Set

TLK-220 EUR SureGrip


Accessory Kit
AC220 SureGrip Alligator
Clip Set
AC285 SureGrip Large Jaw
Alligator Clip Set
TP74 Test Probe Set (4 mm)
TL224 SureGrip Silicone Test
Lead Set
Large zippered soft case with moveable
divider

Industrial Test Leads,


Probes & Clips

Kits
TLK-225-1 SureGrip
Master Accessory Kit
AC220 SureGrip Alligator
Clip Set
AC280 SureGrip Hook
Clip Set
AC283 SureGrip Pincer
Clip Set
AC285 SureGrip Large Jaw
Alligator Clip Set
TP238 SureGrip Insulated Test
Probe Set
TL224 SureGrip Silicone Test Lead Set
6-Pocket Storage Pouch

TLK289 EUR Industrial Master


Test Lead Kit
C116, Soft Case
AC220 Alligator Clip Set
AC280 Hook Clip Set
AC285 Large Jaw
Alligator Clip Set
TP74 Lantern Tip
Test Probe Set
TL224 Test Lead Set
TPAK Hanging Kit
80BK-A Temperature Thermocouple

T5-KIT-1 Accessory Kit


for use with T5
This kit completes the
offering of a T5 with addon probes and
carrying case.
TP238 SureGrip
Insulated Test Probe Set
AC285 SureGrip Large
Jaw Alligator Clip Set
C33 Soft Meter Case

L215 SureGrip Kit


with Probe Light and
Extender
L200 Probe Light
TP280 20 cm Test Probe
Extenders
TP220 SureGrip Test Probes
TL224 SureGrip Silicon Test Lead Set
Foldable soft pouch with six pockets and
hook-and-loop

Modular Test Probes

Modular Test Probes

(for use with Modular Test Leads)

(for use with Modular Test Leads)

TP220-1 SureGrip Test Probe Set

TP80 Electronic Test Probe Set

One pair (red, black) of Industrial test probes


Sharp, 12 mm stainless steel tip
provides reliable contact
Flexible finger barrier improves
grip
Recommended for use
with TL222 and TL224
test leads
CAT II 1000 V, 10 A rating. UL listed

Recommended for use with TL222


and TL224
One pair (red, black)
IC insulated cap prevents
shortening of IC legs for
probing high density components or boards
CAT III 1000 V, 10 A rating. UL listed

TLK291 Fused Test Probe Set


TP74 Lantern Tip Test Probe Set
One pair (red, black)
Tips include banana-style spring contacts
with nickel-plated brass ends
CAT III 1000 V, 10 A rating.
UL listed

TLK290 Test Probe Kit


Kit includes three flexible socket probes
and a large alligator clip
To be used on
three phase sockets.
Probes have flexible width
test points that fit securely in
4 to 8 mm sockets.
Test probe set to be used on
motor and three phase sockets
Safe contact e.g. in CEE 16 A
and CEE 32 A plugs
CAT II 1000 V, 8 A

One pair (red, black) fused test probes


Designed to meet GS38 specs for
United Kingdom
CAT III 1000V, 0.5A
Fuse rating:
500 mA/1000 V/FF/50 kA

FTP-1 SureGrip Fused


Test Probes
Built-in fuses for added
protection
2 mm threaded probe tips include removable
4 mm lantern-style spring contacts
Removable GS38 insulted IC caps for probing
closely spaced leads
CAT III 1000 V, CAT IV 600 V, 10A

TP1-1, TP2-1, TP38


SlimReach Test Probe Sets
One pair (red, black) of slender probes for
closely spaced or recessed terminals
TP1-1: Flat blade design to hold
securely in blade type wall
sockets
TP2-1: 2 mm diameter
tip for electronics work.
Also compatible with AC72.
TP38: Insulated probe tip
(designed to meet GS38
specs for United Kingdom).
TP1-1/TP2-1: CAT II 1000 V
TP38: CAT IV 600 V / CAT III 1000 V
10A rating, UL listed

FTPL-1 SureGrip
Fused Test Probes
with Leads
FTP Fused Test Probes with built-in fuses for
added protection
Includes TL224 Silicone Insulated Test Leads
CAT III 600 V, CAT IV 600 V, 10 A

New
AC285-FTP Alligator
Clips and Adapters
for FTP-1 or FTPL-1
Enhance the usage of your Fluke fused test
leads with this large alligator clip set.
This accessory enables the use of AC285
alligator clips with FTP-1 fused probes.
CAT III 600 V, CAT IV 600 V, 10 A

www.chorus.ro

All accessories have a one year warranty

123

Industrial Test Leads,


Probes & Clips
Modular Clips

Modular Clips

Push-on Clip

(for use with Modular Test Leads)

(for use with Modular Test Leads)

(for use with TL71 and TL75 Test Lead Sets)

AC220 SureGrip Alligator Clip Set

AC285 SureGrip
Large Jaw Alligator Clip Set

AC172 Alligator Clip Set

One pair (red, black) of small, insulated,


nickel plated jaws
Blunt tip grabs round screw heads up
to 9.5 mm
Recommended for use with
TL222 and TL224 test leads
CAT IV 600 V, CAT III
1000 V, 10 A rating.
UL listed

AC280 SureGrip Hook Clip Set


One pair (red, black) of nickel plated clips
Profile narrows to 5.6 mm at
tip, hook opening 6.4 mm at front,
2 mm at base
Recommended for use with
TL222 and TL224 test leads
CAT IV 600 V, CAT III 1000 V,
3 A rating. UL listed

One pair (red, black) of large alligator


clips with nickel-plated steel jaws
Multi-purpose tooth pattern grips
anything from fine gauge wire to
a 20 mm bolt
Recommended for use with
TL222 and TL224 test leads
CAT IV 600 V; CAT III 1000 V, 10 A rating.
UL listed

Slide-on alligator clips (red,


black) for TL175/TL71/TL75
Jaws provide 8 mm opening
CAT IV 600 V, CAT III 1000 V,
10 A rating. UL listed

AC87 Heavy Duty Bus Bar Clip Set


One pair (red, black) of
flat, right angle design
for connecting to bus
bars
Adjustable collar
provides 2 ranges of jaw
openings up to 30 mm
CAT III 600 V, 5 A rating. UL listed

AC283 SureGrip Pincer Clip Set


One pair (red, black) of nickel plated
pincers open to 5 mm
11.4 cm flexible insulated shaft
Recommended for use with
TL222 and TL224 test
leads
CAT IV 600 V, CAT III
1000 V, 1 A rating.
UL listed

AC89 Heavy Duty Insulation


Piercing Test Clip
Single probe pierces
0.25 to 1.5 mm insulated wire
Small pin allows self-healing of the
insulation
CAT IV 600V, CAT III 1000 V, 5 A rating.
UL listed

All accessories have a one year warranty

Fluke TL175 TwistGuard Test Leads


New

Fluke TL175 TwistGuard Test Leads


The new Fluke Tl175 TwistGuard Test Leads are innovative test leads with adjustable length
test tips for use in changing measurement situations. By simply twisting the test lead the
user can change the exposed probe tip length from 19 mm to 4 mm.

TL175

TL175 TwistGuard Test Leads offer:


Patented extendable tip sheath that meet new electrical safety requirements to reduce
tip exposure while providing the versatility needed for most measurements
New WearGuard lead wire wear indication. Each test lead is covered by two layers of silicone insulation; inner
contrasting color is exposed when the leads are nicked, scuffed, or otherwise damaged and in need of replacement
Double insulated silicone leads. TL175 withstands high temperatures and remain flexible in cold temperatures.

124

TL175E

Extra-heavy strain relief on both probe-end and plug-end, testing beyond 30,000 bends without failure.
Universal input plugs compatible with all instruments that accept standard 4 mm shrouded banana plugs
Ratings: CAT II 1000 V, CAT III 1000 V, CAT IV 600 V, 10 A max., Pollution Degree 2
TL175E includes removable 4 mm lantern tips for versatility
Probes always show correct category rating for tip being used
Environmental ratings: -20 C to 55 C, altitude: 2000 m
Conforms to latest safety standard EN61010-031: 2008
One-year warranty
Also available as Test Probe Set, TP175 and TP175E

www.chorus.ro

TP175

Automotive Accessories

Piercing Clips

Pressure Module

TP81 and TP82 Insulation Piercing


Clip Set

PV350 Pressure Vacuum Module

Banana jack accepts all DMM


and banana jack leads
Available for 4 mm input,
modular connection with
TP81 or available as a 2 mm input to
slip onto probe tips with the TP82
Tested to 60 V DC

TP84 Oxygen Sensor Insulation


Piercing Clip
Banana jack accepts
all DMM and banana
jack leads (4 mm)
Tested to 60 V DC

Compatible with all Fluke and most popular


DMMs
Digital pressure and
vacuum measurements in
a single module
Transducer sealed in 316
stainless steel compatible with
variety of liquids and gases
Measures vacuum to 76 cm Hg
Display results in English (psig or Hg) or
metric (kPa or cm Hg) units
Measures pressure to 500 psig (3447 kPa)

90i-610s AC/DC Current Probe (600 A)

Test Leads

Flexible silicone insulated


leads are heat and cold
resistant
CAT I 30 V, 10 A

TP88 Rigid Back Probe Pin Set


Slides onto test probes measuring
2 mm
Tested to 60 V DC

TP40 Automotive Back


Probe Pins (five)
Banana jack accepts all
DMM and banana jack
leads (4 mm)
Tested to 60 V DC

TLK281-1 SureGrip
Automotive
Test Lead Kit
Kit contains:
TP81 Insulation
Piercing Clip Set
TL224 SuregripTM
Silicone Test Lead Set
TP220 SuregripTM Test Probe Set
AC220 SuregripTM Alligator Clip Set
AC285 SuregripTM Large Jaw Alligator Clip Set
Soft Case

BP880
Allows for hands-free
testing in controlled voltage
environments
500 VRMS maximum
Banana plug is nickelBP881
plated, beryllium copper for
low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50C maximum

Current Range: 2 to 600A DC or AC Peak


Basic Accuracy (DC to 400Hz):
(2% of reading + 1A)
Output Signal: 100A range:
10mV/A 600A range: 1mV/A
Frequency Range: 40Hz to
400Hz
Working Voltage: 600V
AC rms
Maximum Conductor
Diameter: 34 mm

Inductive Pick-up
RPM80 Inductive
Pick-up
Provides RPM readings

ScopeMeter
Accessory Kits
SCC128 Automotive
Accessory Kit
(120 Series)

Banana Plugs
BP880 BNC to Female Double
Stacking Banana Plug
BP881 BNC to Male
Double Stacking
Banana Plug

This set of male and female


adapters allows you to make firm
connection to pin and socket
connectors.
Kit contains:
Retractable shrouded test lead set
Complete set of 8 pin-and-socket adapters
with flexible tips
One red and black in different sizes
Rated to 60 V DC

Current Probe

TL28A Automotive
Test Lead Set

Probe Pins

TL 82 Automotive
Pin & Socket Adapter
Kit

TLK282-1 SureGrip
Deluxe Automotive
Test Lead Kit
Kit contains:
TP81 Insulation
Piercing Clip Set
TP40 Automotive
Back Probe Pins
(five)
TL224 SuregripTM
Silicone Test Lead Set
TP238 SuregripTM Insulated Test Probe Set
AC220 SuregripTM Alligator Clip Set
AC285 SuregripTM Large Jaw Alligator
Clip Set
AC280 SuregripTM Hook Clip Set
Soft Case

www.chorus.ro

SCC198 Automotive
Accessory Kit
(190 Series)

These kits provide a host of accessories


that allow you to easily and quickly make
measurements on automotive electronic
systems using a 120 or 190 Series ScopeMeter.

125

Current Clamps

i5s

i50s

i200

i200s

i400

i400s

Specifications AC models
i5s

i50s

i200

i200s

i400

i400s

Nominal current range(s

5A

3/30 AC RMS or DC

200 A

20 A
200 A

400 A

40 A
400 A

Continuous AC current range

0.01 A - 6 A

30 A cont. 50 A<10 sec

0.5 A - 200 A

0.1 - 24 A
0.5 A - 200 A

5 A - 400 A

0.5 - 40 A
5 A - 400 A

Highest current
Lowest measurable current
Basic accuracy (48-65 Hz) 1)

70 A
10 mA
1%

240 A
0.5 A
1% + 0.5 A

240 A
0.5 A
1.5% + 0.5 A

1000 A
1A
2% + 0.15

1000 A
0.5 A
2% + 0.15

Useable frequency
Max. working voltage
Maximum conductor diameter

40 Hz - 5kHz
600 V AC
15 mm

30 A cont. 50 A<10 sec


10 mA
5% typical DC
to 100 kHz
DC to 50 MHz
300 V AC RMS or DC
5 mm

40 Hz - 10 kHz
600 V AC
20 mm

40 Hz - 10 kHz
600 V AC
20 mm

45 Hz - 3 kHz
1000 V
32 mm

45 Hz - 3 kHz
1000 V
32 mm

Output level(s)

400 mV/A

1/100 mV/A

1 mA/A

100 mV/A
10 mV/A

1 mA /A

10 mV/A
1 mV/A

2.5

External Power
2

1.5
O

2.0

1.5
O

2.5

Batttery, battery life


Output cable (m)
Shrouded banana plugs
BNC connector
BNC to banana adapter included
Safety
1)

CAT III. 600 V

i1000s

i2000 flex

O
O
CAT III, 600 V

i3000s flex

i800

i10000s

i2000 flex

Nominal current range(s)

800 A RMS

Continuous AC current range

0.1 A - 800 A RMS

Highest current
Lowest measurable current
Basic accuracy (48-65 Hz) 1)
Useable frequency
Max. working voltage
Maximum conductor diameter

1500 A
0.1 A
0.10%
30 Hz - 10 kHz
600 V AC RMS or DC
54 mm

10 A
100 A
1000 A
0.1 A - 10 A
0.1 A - 100 A
1 A - 1000 A
2000 A
0.1 A
1% + 1 A
5 Hz - 100 kHz
600 V AC
54 mm

20 A
200 A
2000 A
1 A - 20 A
2 A - 200 A AC RMS
30 A - 2000 A
2500 A AC RMS
1A
1%
10 Hz - 20 kHz (-3dB)
600 V AC RMS
178 mm

Output level(s)

1 mA/A

100 mV/A
10 mV/A
1 mV/A

100 mV/A
10 mV/A
1 mV/A
200 hours
0.5
O
n/a
n/a
CAT III, 600 V

Batttery, battery life


Output cable (m)
Shrouded banana plugs
BNC connector
BNC to banana adapter included
Safety

126

O
CAT I 300 V

O
CAT III 1000 V /
CAT IV 600 V

CAT III 1000 V /


CAT IV 600 V

Basic Accuracy: % reading + floorspec

i800

1)

CAT III, 600 V

Basic Accuracy: % reading + floorspec

1.6
O

1.6
O

CAT III, 600 V

CAT III, 600 V

www.chorus.ro

i3000s flex-24
i3000s flex-36
30 A
300 A
3000 A
1 A - 30 A
2 A - 300 A AC RMS
30 A - 3000 A
3500 A AC RMS
1A
1%
10 Hz - 50 kHz (-3dB)
600 V AC RMS
Flex-24 178 mm
Flex-36 275 mm
100 mV/A
10 mV/A
1 mV/A
400 hours
0.5
n/a
O
O
CAT III, 600 V

i3000s

i6000s flex

i3000s

i60000 flex-24
i6000s flex-36
60 A
600 A
6000 A AC
1 A - 6000 A AC RMS

30 A
300 A
3000 A
1 A - 30 A
1 A - 300 A
1 A - 2400 A
4000 A
1A
2% + 2 A
10 Hz - 100 kHz
600 V AC
64 mm

2.1

6000 A
1A
1% of range
10 Hz to 50 kHz
600 V AC RMS or DC
Flex-24 170 mm
Flex-36 275 mm
50 mV/A
5 mV/A
0.5 mV/A
400 hours
0.5

O
O
CAT III, 600 V

O
O
CAT III, 600 V

10 mV/A
1 mV/A
0.1 mV/A

Current Clamps

80i-110s

i30

i30s

i310s

i410

i1010

Specications AC/DC Models


i30
Hall sensor
20 A AC RMS or DC

i30s
Hall sensor
20 A AC RMS or DC

30 A AC Peak

30 A AC Peak

Highest current

80i-110s
Hall sensor
10 A, AC/DC
100 A, AC/DC
0.1 A - 10 A AC/DC
1 A - 100 A AC/DC
140 A - 2 kHz

30 A AC Peak

30 A AC Peak

Lowest measurable current


Basic accuracy 1)
Useable frequency
Zero error adjustment

0.1 A
3% + 50 mA (@ 10 A)
DC - 100 kHz
O

Max. working voltage


Maximum conductor diameter

600 V
11.8 mm

50 mA
1% of reading 2 mA
DC to 20 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm

50 mA
1% of reading 2 mA
DC to 100 kHz (-0.5dB)
manual adjust via
thumbwheel
300 V AC RMS
19 mm

Output level(s)

100 mV/A
10 mV/A
9 V, 55 h
1.6

100 mV/A

100 mV/A

10/1 mV/A

30 hours typical
1.5
O
n/a
n/a
CAT III, 300 V

30 hours typical
2
n/a
O
O
CAT III, 300 V

30 hours
2

Measurement type
Nominal current range(s),
Continuous current range

Battery, battery life


Output cable length (m)
Shrouded banana Plugs
BNC connector
BNC to banana adapter included
Safety

1)

O
CAT II, 600 V
CAT III, 300 V

i310s
AC/DC
30/300 A AC RMS
or 45/450 A DC
100 mA - 300 A AC
RMS or 450 A DC
300 A AC RMS or
450 A DC
100 mA
1% of reading
DC to 20 kHz
Manual

i410
Hall sensor
400 A, AC/DC

400 A

i1010
Hall sensor
600 A, AC
1000 A, DC
1 A - 600 A, AC
1 A - 1000 A, DC
1000 A

0.5 A
3.5% + 0.5 A
DC - 3 kHz
O

0.5 A
2% +0.5 A
DC - 10 kHz
O

300 V AC RMS or DC
19 mm

600 V
30 mm
2 x 25 mm
1 mV/A

600 V
30 mm
2 x 25 mm
1 mV/A

9 V, 60 h
1.6
O

9 V, 60 h
1.6
O

CAT III, 600 V

CAT III, 600 V

1 A - 400 A AC/DC

O
O
CAT III 300 V

Basic Accuracy: % reading + floorspec

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
2
O
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

O
O
2
O
O
O

www.chorus.ro

O
3
O
O

O
O

O
3
O
O

O
3
O
O

O
3
O
O

3
O
O
O

O
O
O
3
3

O
O
O
3
3

O
O
O
3
3

O
O
O
O

O
O
O
2

789

4
2
O
O
O
O

787

O
O
O
2

753/754

O
O
O
2

725

O
O
O
2

724

88V

O
O
O
2

715

83V/87V

O
O
O
2

4
O

1577/1587

77 IV

O
O
O
2

190 Series II / 225C/S

8808A

O
O
O
2

125

8845A/8846

O
O
O
2

123/124

27II / 28II

O
O
O
2

430 Series II

287/289

O
O
O
2

43B

233

Combination of current clamp with


carrying case
Zipped soft case with moveable
divider
Soft case is large enough to hold a
meter

187/189

i410 Kit AC/DC Current Clamp


(400A) with soft case
i1010 Kit AC/DC Current Clamp
(1000A) with soft case

AC Models
i5s
i200
i200s
i400
i400s
i430 flexi-TF
i800
i1000s
i2000 flex (new version)
i3000s
i3000s flex
i6000s flex
AC/DC Models
i30
i30s
80i-110s
i310s
i410 / i410 kit
i1010 / i1010 kit
Other
90i-610s*

175/177/179

113/114/115/116/117

Current Clamp Compatibility Chart

O
O
O
2

O
O
O
2

O
2
O
O
O
O

O
2
O
O
O
O

2
O
O
O

2
O
O
O

2
O
O
O

O
2

O
2
O
O
O
O

2
O
O
O

O
O
O
O

O
O
O

1
1

1
1

1
1

* For specifications of 90i-610s see page 125


1 For DC only
2 Requires PM 9081 (see page 86)
3 Requires PM 9082 (see page 86)
4 115, 117 only

All accessories have a one year warranty

127

Temperature Accessories

DMM Probes

Contact Probes
80PK-22 SureGrip Immersion Probe

80PK-1 and 80PJ-1 Bead Probe

80AK-A Thermocouple Adapter

Type-K thermocouple for use in liquids


and gels
Measurement range:
-40 to 1090C
Probe length: 21.3 cm

80PK-1: Type-K thermocouple for


general purpose applications
80PJ-1 operates with J-type
thermometers
Measurement range:
-40 to 260C
Probe length:
1 m lead wire

Adapts Type-K thermocouple


mini-connector to dual banana
plug inputs
Measurement range and
accuracy: probe dependent
Suitable for low voltage applications
(below 30 V AC, 60 V DC)

80BK-A Integrated DMM


Probe

80PK-24 SureGrip Air Probe


Type-K thermocouple for use in
air and non-caustic gas measurements
Bead protected by
perforated baffle
Measurement range:
-40 to 816C
Probe length: 21.6 cm

80PK-3A Surface Probe


Type-K thermocouple for flat or
curved surfaces such as
plates and rollers
Measurement range:
0 to 260C
Probe length:
9.5 cm

80PK-25 and 80PT-25 SureGrip


Piercing Probe
80PK-25: Type-K thermocouple suitable for
food industry, liquids and gels
80PT-25 operates with T-type
thermometers
Measurement range:
80PK-25: -40 to 350C
80PT-25: -196 to 350C
Probe length: 10.2 cm

128

80PK-8 / 80PK-10 Pipe Clamp


Temperature Probe
Type-K thermocouple for
fast temperature and
superheat measurements
of pipe surfaces
Durable ribbon sensor
Measurement range:
-29 to 149C for pipe diameters
from 6.4 to 34.9mm (80PK-8) and
32 mm to 64 mm (80PK-10)

80PK-26 SureGrip General Purpose


Probe

80PK-9 and 80PJ-9 General


Purpose Probe

Type-K thermocouple with tapered tip


for use in air, non-caustic gas and
surface applications
Measurement range:
-40 to 816C
Probe length: 21.2 cm

80PK-9: Type-K thermocouple surface,


air and non-caustic gases
80PJ-9 operates with
J-type thermometers
Measurement range:
-40C to 260C
Probe length:
15.3 cm

80PK-27 SureGrip Industrial Surface


Probe

80PK-11 Velcro
Temperature Probe

Type-K thermocouple for surfaces


in rugged environment
Durable ribbon sensor
Measurement range: -127
to 600C
Probe length: 20.3 cm

Type-K thermocouple
for hands free
measurement of
HVAC temperature
measuring
applications
Total length of cable:
1m (0.5m in cable, 0.5m
in Velcro cuff insulation material; Hytrel)
Measurement range: -30C to 105C

www.chorus.ro

Type-K thermocouple with


standard banana jack
Convenient one piece
construction
Compatible with DMMs
with temperature
measurement functions
Measurement range:
-40 to 260C

80TK Thermocouple Module


Converts a DMM to
a thermometer
For use with type-K
thermocouples in low voltage
applications (below
24 V AC, 60 V DC)
Measurement range:
-50 to 1000C (probe dependent)

80T-150UA Universal Temperature Probe


Compatible with
Fluke DMM
High accuracy, fast
reading for low voltage
(below 24 V AC, 60 V DC)
applications
Measurement range:
-50 to 150C
Output: 1 mV/C or 1 mV/F (switchable)

SureGrip accessories are designed to


improve steadiness in s lippery hands.
Rubber overmolded surfaces and fingerhugging curves give the user a comfortable,
reliable grip on the accessory so they can
focus on making an accurate measurement.

Temperature Accessories

Other Temperature Accessories


80PK-18 Pipe Clamp Temperature
Probe Kit

80CK-M & 80CJ-M type K & J Male


Mini-Connectors

Thermocouple Plug Kits


700TC1

80PK-8 Pipe Clamp


Temperature Probe
80PK-10 Pipe Clamp
Temperature Probe
Soft Case

Isothermal screw
terminal for K or J
wire
Suitable for up to
20 guage
thermocouple wire
Color coded to
industry standards
(K-yellow, J-black)
Two per package

A kit of 10 mini-plug
connectors
Type J (black), one
Type K (yellow), one
Type T (blue), one
Type E (purple), one
Type R/S (green), one
Type B or CU (white), one
Type L (J-DIN) (blue), one
Type U (T-DIN) (brown), one
Type C (red), one
Type N (orange), one

80PK-EXT, 80PJ-EXT and


80PT-EXT Extension Wire Kits

700TC2

Extending and repairing J, K ot T-type


thermocouple wires
Kit includes 3 meters of thermocouple wire
and 1 pair of male/female mini-connectors
Maximum continuous exposure temperature:
260C
80PK-EXT is compatible
with K-type thermometers,
80PJ-EXT is designed for
J-type thermometers and
PT-EXT for T-type
thermometers

A kit of 7 mini-plug connectors


Type J (black), two
Type K (yellow), two
Type E (purple), one
Type T (blue), one
Type R/S (green), one

190 Series II /225C/S

1577

1587

1
O
O

O
O

O
O

O
O

O
O

O
O

O
O

O
O

O3)
O3)

O
O

O
O

O
O
O

O
O
O

O
O
O

O
O
O

O
O
O

789

120 Series

787

43B

753/754

88V

725

87V

724

83V

715

77IV

714

8845A/8846A/8808A

705/707

27II / 28II

66/68

287/289

566/568

233

561

179

51/52/53/54 II

175/177

Contact Probes
80PK-1 80PK-27
80PJ-1, 80PJ-9
80PT-25
DMM probes
80AK-A
80BK-A
80TK
80T-150UA
Miscellaneous
80CK-M
80CJ-M
80PK-EXT4)
80PJ-EXT
80PT-EXT
700TC1, 700TC2
80PR-60

113/114/115/116/117

Temperature Probe Compatibility Chart

O
O

O
O

O
O

O
O
O
O
O
O

O
O
O
O

O
O

O
O

O
O

www.chorus.ro

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O
O

1
1

O
O
O
O
O
O

O
O
O
O
O
O

1) Requires 80TK
2) Requires 80AK
3) Fluke 116 only
4) Also requires 80CK-M

All accessories have a one year warranty

129

Cases and Holsters


Soft Cases
Zipped carrying cases protect your meter; most cases come with belt loops so your meter is
stored conveniently on your tool belt.

C12A

C23

C43

C115

C25

C33

C50

C116

Zipped carrying
case with storage
compartments
Allows hand or
shoulder use

C789

C35

C75

C125/C781

C195

Large fabric carrying case


with 3 compartments,
removable handle and
shoulder strap

C550 Tool Bag

C90

C280

Steel reinforced frame


Rugged ballistic cloth
with heavy duty
hardware
Large zippered storage
compartment with
25 pockets
Weather resistant
Carry all your tools to
the job

C345

130

787

789

753/754

724/725/726

718

712/714/715/717

705/707

63/66/68

61

570 Series

51/52/53/54 II

O
O

566/568

971

O
O

561

922

190 Series II

43B/120 Series

430 Series II

9040/9062

1735/1740 Series

1503/1507/1577/1587

353/355

333/334/335/336/337/902

321/322

T100 Series

T50

T5

O
O
O
O

83V/87V/88V

77 IV

27II / 28II

287/289

O
O
O

233

175/177/179

Soft Cases
Size (HxWxD) mm
C12A
172 x 128 x 38
C23
225 x 95 x 58
C25
218 x 128 x 64
C33
280 x 115 x 55
C35
220 x 140 x 65
C43
318 x 230 x 90
C50
192 x 90 x 38
C75
179 x 103 x 26
C90
205 x 90 x 72
C115
240 x 205 x 75
C116
240 x 230 x 65
C125
192 x 141 x 58
C195
231 x 513 x 231
C280
230 x 185 x 65
C345
240 x 360 x 200
C437-II
C550
333 x 513 x 231
C781
269 x 141 x 90
C789
308 x 256 x 77
C799
305 x 229 x 165
Hard cases
C20
256 x 154 x 106
C100
397 x 346 x 122
C101
305 x 360 x 105
C120
346 x 397 x 128
C290
410 x 474 x 135
C435
565 x 476 x 305
C800
230 x 385 x 115
C1600
260 x 390 x 200
CXT80
28 x 32 x 13
CXT170
28 x 32 x 13
CXT280
28 x 32 x 13
Leather Cases
C510
287 x 179 x 106
C520A
256 x 154 x 106
Holsters
C10
154 x 77 x 45
H80M
190 x 95 x 43
Other
H3
231 x 90 x 64
H5
192 x 90 x 38
H6
302 x 178 x 57
Hanging Kit (see page 132)
ToolPak

113/114/115/116/117

Cases & Holsters Compatibility Chart

O
O

O
O
O

For multiple test leads and accessories


O O O

O
O

O
O
O
O

O
O
O
O
O

O
O

O
O

O O O O O O O
For multiple test leads and accessories

O
O

O
For multiple test leads and accessories
O
O
O O
O O
O O O O O O O
O

O
O

O
O

O
O

O
O

O
O

O
O
O

O
O

O
O

O
O

O
O

O
O
O

O
O

O
O
O

O
O
O
O O
O O O
For multiple test leads and accessories
O
O
O
O

O
O

O
O

O
O

www.chorus.ro

O
O

O
O

Cases and Holsters


Hard Cases

Holsters

C20 Meter Case

C10 Meter Holster

H3 Clamp Meter Holster

Heavy duty case with


carrying handle and
accessories storage
compartment
Top cover snaps onto back to
serve as tilt stand

Snap-on yellow holster


absorbs shocks and protects
meter from rough handling
Includes built-in stand and
hanger loop

Fabric holster absorbs


shocks and protects
meter from rough
handling.
Built-in pocket for lead
storage
Convenient belt-loop with snap

H80M Holster + Magnetic Hanger


C100 Meter and
Accessory Case
Tough polyprophylene case

C101 Hard Case


The hard case that fits all Fluke
industrial test tools. Configure
the diced foam interior to store
and protect what you need to
carry with you.
Tough polyprophylene exterior shell
Interior cavity measures

Snap-on yellow
holster absorbs shocks
and protects meter from
rough handling
Magnet, hook and loop
straps
General purpose hanger

H5 Electrical Tester Holster


Rugged fabric holster includes flap for lead
storage and built-in belt
loop
Fits Fluke T3 and T5
testers

H6 Infrared Thermometer Holster


Durable nylon holster
For Fluke 63, 66 and 68 Infrared
Thermometers

C120 and C290 Cases


Heavy duty cases with accessory
storage compartments

C435 Hard Rolling Case


Watertight hard case
with rollers for 430 Series,
1735 and 1740 Series
Power Quality products and
accessories. The
configurable foam securely
holds any of these
instruments during transit.

C800 Meter and Accessory Case

Leather Cases
C510 Leather Meter Case

C520A Leather Tester Case

Oiled genuine top grain cowhide


Rugged construction with heavy duty
stitching and reinforced rivets
Large tool belt loop and
top flap to secure meter
Holds most Fluke DMMs,
Thermometers, and
Process Calibrators

Oiled genuine top grain cowhide


Oil tanned for long life
Rugged construction with heavy duty
stitching and reinforced rivets
Large tool belt loop and
top flap to secure tester
Holds Fluke Electrical
Testers

Tough polyprophylene case


Accessories and manual
compartments
Detachable lid

C1600 Meter and Accessories Case


Rugged molded plastic case
Deep interior large enough to hold
and protect your tools
Lift out tray keeps
everything organized
Snap open compartment
on top of lid

CXT80, CXT170, CXT280 Rugged Pelican


Hard Case

www.chorus.ro
Unbreakable, watertight,
airtight, dustproof, chemical
resistant and corrosion proof
case

All accessories have a one year warranty

131

Software and other Accessories

Software FlukeView Forms

Hanging Kit

FlukeView Forms increases the power of your


Fluke tool by enabling you to document, store
and analyze individual readings or series
of measurements, then convert them into
professional-looking documents. FlukeView
Forms supports the following multimeters:

ToolPak (TPAK)
The meter hanging solution
Kit includes, universal hanger clips (2), hook
& loop straps (2 lengths) and strong magnet
Combine components to meet most hanging
needs
See page 130 for compatibility chart

FlukeView Forms Compatibility Chart


FVF Option
FVF-UG
FVF-SC2
FVF-SC4
FVF-BASIC
FVF-SC5

Instrument
Software only upgrade, Any instrument that supports
Flukeview Forms Software
Fluke 280 Series, 789, 1550B, 1653B, 568,180 Series*, 53B, 54B
Fluke 8808A, 8845A, 8846A, 45*, 975
Fluke 280 Series, 789, 1550B, 1653B, 180 Series*
8808A, 8845A, 8846A, 45*

Cable**
No Cable included
USB / IR
USB / Serial
USB / IR
USB / Serial

Application Level
FVF Full
(includes Designer)
FVF BASIC

* Obsolete
** USB cables are not supported for Microsoft Windows NT 4.0

IR189USB
IR to USB interface cable
(included with FVF-SC2 and FVF-Basic)
For customers who want to upgrade from
their existing RS232 cable
Small adapter to connect the cable to the 189,
287, 289, 1653B or the 1550B is included.

Fiber Optics
FOM Fiber Optic Meter

Make extended logging easier


BP189 High Capacity Battery Enclosure
(for Fluke 180 Series DMM)
Expand the battery life of your Fluke
187/189 up to 450 hours (over two weeks of
continuous use).
Houses 4 C cell batteries.
CAT III 1000 V, CAT IV 600 V
Batteries and meter sold separately

132

www.chorus.ro

The Fluke Fiber Optic Meter (FOM) helps you


test and maintain fiber optic cables without
having to buy a whole new
meter. Plug the FOM
directly into any DMM with
a mV dc function and a
10 M input impedance and
quickly and accurately
verify fiber optic cable system loss. Light
sources and patch cords sold separately.

FOS 850 & FOS 850/1300


Fiber Optic Light Sources
A variety of light sources allow you to test
different cable lengths.

All accessories have a one year warranty

Other Accessories

Lights

Stray Voltage Adapter

High Voltage Probes

L200 Probe Light

SV225 Stray Voltage Adapter

80K-6 and 80K-40

Attaches to any Fluke test probe


Bright white LED
120 hours of battery life

Stray voltage can appear in


electrical installations, due to
the capacity between wires.
This may result in erroneous
readings on high impedance
meters.

A high voltage probe that


allows a multimeter to
measure up to 6,000V or
40,000V respectively.
Intended for low energy applications only

L205 Mini Hat Light


Rugged high-intensity
Xenon worklight
Attaches to a baseball cap
Includes a hat clip
Includes two AAA
batteries
Waterproof

L206 Deluxe LED Hat Light


(hard hat not included)
Attach it to a hard hat,
a baseball cap, or even a
panel door for all the light
you need.
3 super bright white LEDs
never burn out
Special hard-hat attachment included
40-hour battery life
Includes three AAA batteries

The SV225 solves this without


compromising safety.
On energized wires, the meter will indicate
the real voltage.
On non-energized circuits the meter
will read close to zero (even if there
are stray voltages).
It can be used with all modern
meters with standard input spacing.
Rated CAT III 1000 V, CAT IV 600 V

TL225-1 SureGrip Stray Voltage Adapter


Test Lead Kit
Kit includes:
SV225 Stray Voltage
Eliminator
TL224 SureGrip
Silicone Test Lead Set
(right to straight)
TP238 SureGrip
Insulated Test Probe Set
C75 Accessory Case

L210 Probe Light +


Probe Extender
Includes L200 Probe Light
and TP280 Test Probe
Extenders
20 cm probe extenders
keep hands away from
live circuits
Extender fits between modular test probe
and test lead (total reach 30 cm)

Meter Cleaners
MC6 MeterCleaner Wipes (6-pack)
MC50 MeterCleaner Wipes
(50-pack)
Pre-moistened wipe removes dirt, oil and
grease
One wipe easily cleans one meter
Safe on rubber, plastic and for environment
(non-toxic)

www.chorus.ro

All accessories have a one year warranty

133

Fuse and Warranty Information


Product Warranty
Each Fluke product is warranted to be free from defects
in material and workmanship under normal use and
service, for the warranty period listed unless local law
requires a longer period. The warranty period is listed
in the ordering information section of the product
specification and begins on the date of shipment.
This warranty extends only to the original buyer or
end-user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to any
product which, in Flukes opinion, has been misused,
altered, neglected or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that
software will operate substantially in accordance with its
functional specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke does
not warrant that software will be error free or operate
without interruption.

Lifetime Warranty

Fuse Replacement Information


A
63mA (slow)
125mA (slow)
250mA (slow)
315 mA
440mA
500mA
630mA
1A
1A
1.25A
3.15A
11A
11A
15A
20A

V
250V
250V
250V
1000V
1000V
250V
250V
600V
500V
600V
500V
1000V
1000V
600V
600V

Size
Part nr
in mm
qty 1
6.35x32
163030
6.35x32
166488
6.35x32
166306
10KA
6.35x32
2279339
10kA
10.3x34.9
943121
1500A
5x20
838151
1500A
5x20
740670
10kA
10.3x34.9
830828
50kA
6.35x 32
2530449
6.35x32
2040349
6.35x32
2030852
17kA
Replaced by 11A, 1000V, 20kA fuse; 803293
20kA
10.3x38.1
803293
100kA
10.3x38.1
892583
Replaced by 15A, 600V, 100kA fuse; part nr. 892583
IR

See the back of your Fluke test tool or user manual for the fuses installed.
For manuals check the Fluke website in the product section.
For Fuse Replacement Guide check the Fluke website in the service section.

134

www.chorus.ro

Each Fluke 20, 70, 80, 170, 180 and 280 Series DMM
purchased after October 1, 1996 will be free from defects
in material and workmanship for its lifetime. This
warranty does not cover fuses, disposable batteries and
damage from accident, neglect, contamination, misuse or
abnormal conditions of operation or handling, including
overvoltage failures caused by use outside the DMMs
specified rating, or normal wear and tear of mechanical
components. This warranty covers the original purchaser
only and is not transferable. For ten years from the
date of purchase, this warranty also covers the LCD.
Thereafter, for the lifetime of the DMM, Fluke will replace
the LCD for a fee based on then current component
acquisition costs.
To establish original ownership and prove date of
purchase, please complete and return the registration
card accompanying the product.

Service
Fluke will, at its discretion, repair at no charge, replace
or refund the purchase price of a defective product
purchased through a Fluke authorized sales outlet and at
the applicable international price. Fluke reserves the right
to charge for importation costs of repair/replacement
parts if product purchased in one country is sent for
repair elsewhere.
Send defective product with a description of the
problem to the nearest Fluke Authorized Service Center,
postage and insurance prepaid. Fluke will pay return
transportation for product repaired or replaced inwarranty. Before making any non-warranty repair, Fluke
will estimate cost and obtain authorization, then invoice
you for repair and return transportation.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING
LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO
EXTEND ANY DIFFERENT WARRANTY ON FLUKES
BEHALF.
Since some states do not allow the exclusion or
limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may
not apply to you.

www.chorus.ro

135

136

www.chorus.ro

www.chorus.ro

Fluke. Keeping your world


up and running.
Fluke Corporation
P.O. Box 9090
Everett, WA USA 98206

Web: www.fluke.com
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Web: www.fluke.eu
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446-5116
In Europe/M-East/AFrica +31 (0)40 2 675 200)
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6866
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116

Fluke (UK) Ltd.


52 Hurricane Way
Norwich
Norfolk
NR6 6 JB
United Kingdom
Tel.: (020) 7942 0700
Fax.: (020) 7942 0701
E-mail: industrial@uk.fluke.nl

www.chorus.ro

Web: www.fluke.co.uk
Copyright 2012, Fluke Corporation.
All rights reserved.
Printed in the Netherlands, 01/12