Addendum Modbus/TCP Communications Board.: Scroll 9600 No Parity 1 8 Modbus Disabled 1 None
Addendum Modbus/TCP Communications Board.: Scroll 9600 No Parity 1 8 Modbus Disabled 1 None
Addendum Modbus/TCP Communications Board.: Scroll 9600 No Parity 1 8 Modbus Disabled 1 None
Scroll
9600
No parity
1
8
MODBUS
Disabled
1
None
The Modbus/TCP server will plug in to any slot on the Microtech 2000 series integrators
but the end plate is tight and may need to be nibbled out. Set up is same as MT3000
series.
Rec4251 Rev A
P/N 085719
The Ethernet address is also referred to as the hardware address or MAC address. The
first three bytes of the Ethernet address are fixed and read 00-20-4A, identifying the unit
as a Lantronix product. The fourth, fifth, & sixth bytes are unique numbers assigned to
each unit.
Mac Address label example
00-20-4A-71-9E-0C
Reference the appropriate Serial Communications manual for your Microtech Integrator
for the Modbus Data address registers.
Model
MT2100, MT3100
MT2001, MT2101, MT2201. MT2301, MT3101
MT2102
MT2104
MT2105, MT2305, MT3105
MT2106, MT3106
MT2107, MT3107
Rec4251 Rev A
P/N 085719
Manual
REC 3948
REC 3949
REC 4037
REC 3951
REC 3952
REC 3953
REC 3987
00:20:4A:74:05:52
Rec4251 Rev A
P/N 085719
DeviceInstaller
You can manually assign the IP address using DeviceInstaller software. This
software can be downloaded from the Lantronix web site at:
http://www.lantronix.com/support/utils/dst/index.html
Once at the web site select Download the latest version of
DeviceInstaller. At the next screen, select Download Device Installer
v2.0 via FTP.
Appendix Figure 0-1: Lantronix Web Selections
A90875
A90876
Rec4251 Rev A
P/N 085719
A90877
A90878
Rec4251 Rev A
P/N 085719
A90879
Confirm the Reply received messages display in the window indicating the IP address has
been entered successfully.
Note: If you do not receive Reply received messages, make sure the unit is
properly attached to the network and that the IP address assigned is valid for
the particular network segment you are working with. If you are not sure,
check with your systems administrator.
Click Back to return to the DeviceInstaller main window.
Rec4251 Rev A
P/N 085719
A90880
Rec4251 Rev A
P/N 085719
Status LEDs
The Cobox-Micro has four LEDs: channel 1 status, channel 2 status, diagnostics, and
network link status. See table for description.
Red Diagonstics
Green Channel 1 (blinks green when active)
3
LED
1
Description
Green
Channel 1
status
Yellow
Channel 2
status
Red
Diagnostics
Green
Network Link
Status
* Non-fatal error
Rec4251 Rev A
P/N 085719
LED Function
Lights solid green to indicate channel 1 is idle. Blinks to
indicate Channel 1 is connected to the network and active.
Lights solid yellow to indicate channel 1 is idle. Blinks to
indicate Channel 1 is connected to the network and active.
Blinks or lights solid red in combination with the green
channel 1 LED to indicate diagnostics and error detection.
Red solid, green channel 1 blinking.
1x: EPROM checksum error
2x: Ram error
3x: Network controller error
4x: EEPROM checksum error
5x: Duplicate IP address on network *
6x: Software does not match hardware *
Red blinking, green channel 1 blinking
4x: Faulty network connection *
5x: No DHCP response received *
Lights solid green to indicate network port is connected to the
network.