Final Datasheet Experiment 2 - Medium Length Line Nominal T Method Table 1A. Resistive Load (C=8μ μ F)

This document summarizes the results of an experiment using the nominal T method to determine the characteristics of a medium length transmission line with resistive and inductive loads. Tables of data show voltage, current, power and efficiency measurements taken at increasing percentages of rated voltage for lines with capacitances of 8μF and 16μF, both with and without a 25% inductive load. The rated voltages determined were 139.76V and 143.14V.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views

Final Datasheet Experiment 2 - Medium Length Line Nominal T Method Table 1A. Resistive Load (C=8μ μ F)

This document summarizes the results of an experiment using the nominal T method to determine the characteristics of a medium length transmission line with resistive and inductive loads. Tables of data show voltage, current, power and efficiency measurements taken at increasing percentages of rated voltage for lines with capacitances of 8μF and 16μF, both with and without a 25% inductive load. The rated voltages determined were 139.76V and 143.14V.
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

EE117L EXPERIMENT NO.

2
NOMINAL T METHOD

MEDIUM LENGTH LINE

FINAL DATASHEET
Experiment 2 - Medium Length Line Nominal T Method
Table 1A. Resistive Load (C=8 F)
Trial

VS

IS

PS

VD1

IC1 IC2

VR

IR

PR

pfR

25%

136

1.4
2

192.
1

19.8
1

0.22

50%

135.4

2.6
1

344.
6

37.4
5

75%

134.1

3.6
3

464

100%

134

4.4
9

125%

133.3

150%

133.1

%VR

%Ef

0.2

1.45

133.5
1

1.40

187.2
5

1.865

97.47
5

0.22

0.18

2.72

125.8

2.64

332.5
3

7.631

96.49
7

51.7
7

0.22

0.17

3.80
A

116.8
8

3.40
A

433

14.73
3

93.31
9

547

64.2

0.22

0.16

4.70

109.5
4

4.57

501

22.33
0

91.59
0

5.2
0

598

73.7

0.22

0.14

5.49

101.7
5

5.31

539.9
6

31.00
7

90.29
4

5.8
1

630

81.9

0.22

0.14

6.20

94.63

5.93

560.9

40.65
3

89.03
2

VRNL = 139.01 V
Table 1B. Resistive Load (C=16 F)
Trial

VS

IS

PS

VD1

IC1

IC2

VR

IR

PR

pfR

%VR

%Ef

25%

135.96

1.59

200

20.87

0.42

0.42

1.52

135.78

1.42

193.29

0.133

96.645

50%

135.30

2.69

363.5

38.41

0.42

0.39

2.80

127.72

2.7

344.81

5.935

94.858

75%

134.6

3.67

481

53.01

0.42

0.36

3.85

118.91

3.76

447

13.195

92.931

100%

134.1

4.49

563

69.01

0.42

0.34

4.75

111

4.64

514

20.811

91.297

125%

133.6

5.19

604

74.8

0.42

0.30

5.55

103.1

5.38

554.12

29.583

91.742

150%

133

5.77

646

82.6

0.42

0.28

6.19

95.84

5.99

575.60

38.773

89.102

EE117L EXPERIMENT NO. 2


NOMINAL T METHOD

VRNL = 142.02

MEDIUM LENGTH LINE

Table 2A. Resistive and Inductive Loads (C=8 F)


Trial

VS

IS

PS

VD1

IC1

IC2

VR

IR

PR

pfR

%VR

%Ef

25%

136.1

1.55

165.2

23.45

0.22

0.18

1.72

118.01

1.79

158.01

0.748

15.329

95.648

50%

135.7

2.54

295.5

37.33

0.22

0.17

2.73

112.56

2.72

278.68

0.908

20.558

94.308

75%

135.5

3.48

401

50.24

0.22

0.16

3.69

106.8

3.63

371.25

0.954

26.873

92.581

100%

135.8

4.29

481

61.9

0.22

0.14

4.54

101.25

4.44

438.31

0.973

34.123

91.125

125%

134.9

4.98

533

71.1

0.22

0.14

5.25

94.93

5.13

476.65

0.982

42.105

89.428

150%

134.6

5.56

568

79.5

0.22

0.13

5.90

88.87

5.74

503.96

0.987

51.457

88.725

Note: Use 25% inductive load for all trials.


VRNL = 139.76
V

EE117L EXPERIMENT NO. 2


NOMINAL T METHOD

MEDIUM LENGTH LINE

Table 2B. Resistive and Inductive Loads (C=16 F)


Trial

VS

IS

PS

VD1

IC1

IC2

VR

IR

PR

pfR

%VR

%Ef

25%

136.2

1.38

170.6

22.49

0.42

0.36

1.66

120.22

1.82

164.9

0.748

13.292

96.659

50%

135.8

2.45

303.5

37.23

0.42

0.34

2.70

114.36

2.77

287.31

0.908

18.748

94.666

75%

136.2

3.41

414

50.77

0.42

0.33

3.71

108.84

3.69

384

0.954

25.138

92.754

100%

135.7

4.22

491

61.86

0.42

0.31

4.56

102.47

4.5

448.21

0.973

32.429

91.285

125%

134.7

4.89

542

71.6

0.42

0.28

5.30

96.86

5.20

490.03

0.982

39.067

90.411

150%

134.6

5.49

580

79.9

0.42

0.28

5.90

89.88

5.79

514.59

0.987

49.755

88.722

Note: Use 25% inductive load for all trials.


VRNL = 143.14 V