Page : 3 of 6
(b)
At the beginning of door extension, the limit switches of LG retracted position are
opened and the three green lights of the LG mnemonic frame start flashing. Once the
LG doors are fully extended and locked in down position, the electrical signal is
applied to LG valve KE-53-8 through door extended position limit switches. The LG
valve energizes and communicates the delivery line to LG extension line and return
line to retraction line. Now the oil under pressure is supplied to :(a)
Main LG down lock for preparing it to receive LG down lock bar ball.
(b)
(c)
Once the main and nose landing gears are extended and locked in down position, the
limit switches close the extension circuit and the three greens in the LG mnemonic
frame will stop flashing. At the same time LG Down, sector will be illuminated on the
front instrument panel. In this condition, if taxy light is set to ON position, the taxy light
will be illuminated.
TP-060-3:2013-C01/P(1/9)
Page : 4 of 6
(b)
Main and Nose LG up locks for preparing it to receive the up lock hooks.
(c)
(d)
At the beginning of landing gear retraction, as the limit switches of landing gear down
position are opened, the LG extended position green light flashes Simultaneously LG
DOWN green light goes OFF on the front instrument panel.
Once the LG is
retracted fully and locked in UP position, electrical signal is applied to door valve KE53-8 through LG up lock limit switches. The valve changes over and communicates
the delivery line to the retraction line and return line to extension line.
Now, the
(b)
Actuating cylinders for breaking down lock and retracting its rods.
Once the LG doors are fully retracted and locked in up position, the limit switches are
opened up and both the door and LG valves KE-53-8 are de-energized. The valves
will change over and take the neutral position so that both extension and retraction
line are connected to return line. At the same time the limit switches closes the LG
retraction circuit and the three green lights extinguish.
EMERGENCY EXTENSION LANDING GEAR
On the first pull of the emergency extension handle, the electro hydraulic selector
valves KE-53-08 are de-energized and door electro pneumatic valve 702800 M is
energized. This will supply compressed nitrogen to door up-locks through shuttle
valves and opens the up-locks. The compressed nitrogen is also delivered to the door
TP-060-3:2013-C01/P(1/9)
Page : 5 of 6
retracting struts through the shuttle valves (the hydraulic line is disconnected) and the
landing gears are extended and locked down in extended position. The landing gear
indication is available on LG mnemonic frame.
SOALAN/QUESTION :
1.
only?
2.
Why aircraft Su-30MKM have emergency system for landing gear extension
TP-060-3:2013-C01/P(1/9)
Page : 6 of 6
SOALAN/QUESTION :
1.
Why aircraft Su-30MKM have emergency system for landing gear extension
only?
2.
A.
The check carried out after the last flight of the day or if the defect found and
The check which combines few task of pre-flight and post flight inspection.
C.
3.
A.
To ensure that the aircraft is fit for flight before its first flight of the day.
B.
To ensure that the aircraft is thoroughly inspect after the last flight.
C.
To ensure that the aircraft is properly examine between two flight task.
RUJUKAN/REFERENCE:
1.
2.
Risalah No. 2.
3.
AKPUTD Jilid 2.
4.
5.