Clarus 500 Gas Chromatography PDF
Clarus 500 Gas Chromatography PDF
Clarus 500 Gas Chromatography PDF
Oven
The Clarus 500 GC oven provides easy access to
columns. The oven gives excellent temperature
control and fast cool-down times for maximum
productivity. All temperature and time functions
are microprocessor controlled and are shown on
the touch-screen display. Software selectable
coolant time-out and coolant cut-in temperatures
ensure economical subambient operation.
Volume:
10,600 cm3
Temperature
range:
3 ramp, 4 plateaus
Minimum
Range
Increment
Initial oven
temperature:
-99 C to 450 C
1 C
Initial time:
0 to 999 min
0.1 min
Rate:
0.1 to 45 C/min
0.1 C
Plateau time:
0 to 999 min
0.1 min
Final oven
temperature:
-99 C to 450 C
1 C
Cool-down
times:
www.perkinelmer.com
S P E C I F I C A T I O N S
G A S C H R O M ATO G R A P H Y
Clarus 500
Gas Chromatograph
Injectors
Packed-column injector
Removable glass liner for trapping nonvolatile residues
Adapter for on-column injection to wide-bore
capillary columns
Autosampler
50 C to 450 C in 1 C increments
The Clarus 500 GC offers an optional, built-in syringe
autosampler for maximum sampling capabilities. All
control is accomplished through the keyboard or by a
data system such as TotalChrom.
Injection speed:
Program modes:
Number of sample
positions:
Vial size:
1/8-inch fitting
1/4-inch column adapter available
Conventional pneumatics choice of flow controller
with head-pressure gauge, or flow controller with
head-pressure gauge and digital display of flow
PPC pneumatics programmed flow or pressure
includes readout which displays pressure or
column flow
Split/splitless capillary injector
Number of waste
and wash vials:
4 mL
Syringe size:
Sampling volume:
Viscosity settings:
0-15
Maximum number
of injections/vial:
15
Maximum number of 15
solvent postwashes:
Maximum number
of sample pumps:
15
Programmable on-column capillary injector
Maximum number
15
of sample prewashes:
Minimum sample
volume required:
Reproducibility:
1/16-inch fitting
Temperature-programmable inlet
Three-ramps temperature program
Oven tracking mode for simple operation
50 C to 500 C in 1 C increments
Heating rate of 1 C/min to 200 C/min or ballistic
1/16-inch fitting
50 C to 500 C in 1 C increments
Heating rate of 1 C/min to 200 C/min or ballistic
1/16-inch fitting
Conventional pneumatics pressure regulator (0-60 psig)
for digital display of column head pressure. Automatic
control of split vent solenoid valve
PPC pneumatics four software configurable modes:
programmed flow, programmed pressure, programmed
velocity or constant flow. Vacuum compensation
software selectable
PPC pneumatics include automatic control of split vent
by split flow or split ratio
PreVent
Unique PerkinElmer sample management system
Detectors
A wide choice of detectors optimized for sensitivity and
selectivity is available for use with the Clarus 500 GC.
All built-in detectors include an automated background
compensation feature that corrects for column bleed.
Whether you choose the Flame Ionization Detector, the
Thermal Conductivity Detector, the Electron Capture
Detector, and/or environmental-specific detectors, all
conform to the highest industry standards for reliability
and performance. Every detector except the Electrolytic
Conductivity Detector (ELCD) is available with PPC or
conventional pneumatics. Up to two detector modules
may be installed and operated simultaneously with
independent temperature and pneumatic control.
Flame Ionization Detector (FID)
Operating
temperature:
Operating
temperature:
Sensitivity:
Sensitivity:
Minimum
detectable
quantity:
-12
Linearity:
> 10
Signal filtration:
Minimum
detectable
quantity:
Input range:
1, 20
Linearity:
> 105
Makeup gas:
Not required
Power supply:
Signal filtration:
1/8-inch fittings
Conventional pneumatics needle valve for makeup gas
Filament
protection:
Makeup gas:
Source:
15 mCi 63Ni
Temperature
protect:
470 C by software
Carrier gas:
Either Ar/CH4 or N2
Operating
temperature:
Minimum
detectable
quantity:
Linearity:
> 10
Signal filtration:
1/8-inch fittings
Makeup gas:
Standard
Operating
temperature:
Minimum
detectable
quantity:
1/8-inch fittings
Linearity:
> 107
Signal filtration:
Input range:
1, 20
Makeup gas:
Standard
Capillary-column compatible
Proven constant current design
Software protection to prevent filament burnout
www.perkinelmer.com
Combination PID/ELCD
1/8-inch fittings
1/8-inch fittings
Operating
temperature:
Sensitivity:
Operating
temperature:
Linearity:
> 10
Selectivity:
Minimum
detectable
quantity:
Makeup gas:
Linearity:
Signal filtration:
Modular design
Selectivity:
10,000:1 (S/C)
100,000:1 (P/C)
Makeup gas:
Not required
Operating
temperature:
Minimum
detectable
quantity:
5 1013 g N/sec
2,4-dimethylaniline
5 1014 g P/sec tributylphosphate
Linearity:
> 104
Password protection
Signal filtration:
Selectivity:
50,000:1 (N/C)
10:1 (P/N)
Status-summary screen
Input range:
1, 20
Makeup gas:
Not required
Log file
Resolution: 240 x 320
256-color display
Meaningful error/alarm messages
www.perkinelmer.com
Physical details
Power
requirements:
Ambient
temperature:
10 C to 32 C
Ambient humidity:
3400
Weight
GC:
Autosampler:
49 kg (108 lb)
4.5 kg (10 lb)
KG050604