Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Fire Pump Brochure - BRISTOL

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Fire Pumps

Bristol: A History & Future.


In 1971, seven emirates joined forces to create the United Arab Emirates, with the goal of becoming a growing leader on an international
scale. The UAE’s focus has always been the safety of its land and people, BRISTOL was established in support of that same vision.

BRISTOL FIRE ENGINEERING, part of the Concorde – Corodex Group, is the leading fire-fighting and fire protection manufacturer in the
Middle East and has been unsurpassed in innovative fire-fighting solutions for more than 44 years.

We have been steadfast in our developments and have grown to become pioneers in the industry for unmatched quality and dependability,
longstanding commitment and unwavering dedication.

Our headquarters and manufacturing facility started in the UAE’s Emirate of Dubai, producing world-class fire-fighting systems and equipment
in cooperation with international know-how and technology with a grand vision to expand globally.

We strive to continue to adopt the highest international and national standards in line with the UAE’s goal to become the safest country in the
world.

BRISTOL was one of the first fire-fighting companies in the Middle East to receive an ISO 9001 certification, placing great emphasis on
achieving local and international approvals on product certifications such as Kite Mark, LPBC, UL listing, and FM approval. Moreover, Bristol
is certified to ISO 14001 and OHSAS 18001.

We focus on innovation by means of continual research and development of advanced fire-fighting solutions, ensuring we not only meet, but
exceed the demands of our rapidly changing market.

For decades, we have been proudly supplying various government entities and sectors such as the oil and gas, commercial, and industrial
sectors across the globe with world-class equipment and services.

BRISTOL has been serving Middle Eastern, African, Asian, and European markets for more than four decades with a vision to expand further.

Paving the road towards safety for more than four decades, and counting: BRISTOL.
Table of Contents:

Firer Pumps - End Suction 4

Fire Pump - Horizontal Split Case 8

Fire Pumps - Vertical Turbine 12

3
Fire Pumps - End Suction
Bristol End Suction Pumps are designed according to NFPA 20 for Fire Fighting applications. This pump
is designed with latest technology and has premium components for fast maintenance and absolute
efficiency.

4
Performance Range
- Capacity : From 50 GPM up to 1000 GPM
- Head : From 40 MTR up to 160 MTR

Features
- Available in electric motor driven or engine driven configuration
- Dynamic balanced impellers
- Available in clockwise or counter-clockwise rotation to simplify pump
- room layout
- UL Certificate No. : Ex16459

Material Construction
- Shaft : Stainless Steel
- Casing : Ductile Iron
- Impeller : Bronze
- Shaft Seal : Packing Gland-Immersion Graphite

General Information for Centrifugal Fire Pumps, End Suction

Rated Capacity Rated Net Pressure Approx Speed Rated Capacity Rated Net Pressure Approx Speed
Model Size (In) Model Size (In)
(GPM) Range (psi) (RPM) (GPM) Range (psi) (RPM)

IS32 – 200 50 2x1¼ 62-95 2950 IS65 – 320H 300 3 x 2½ 97-181 2800

IS32 – 200 50 2x1¼ 55-85 2800 IS65 – 320H 300 3 x 2½ 98-152 2600

IS32 – 260 50 2x1¼ 113 - 130 2950 IS65 – 320H 300 3 x 2½ 82-128 2400

IS32 – 260 100 2x1¼ 103 - 125 2950 IS80 - 260 400 4x3 105-139 2950

IS50 – 320H 50 2½ x 2 103-167 2600 IS80 - 260 500 4x3 101-137 2950

IS50 – 320H 50 2½ x 2 88-142 2400 IS80 – 320H 300 4x3 159-203 2950

IS50 – 320H 100 2½ x 2 178-298 3500 IS80 – 320H 300 4x3 143-183 2800

IS50 – 320H 100 2½ x 2 132-210 2950 IS80 – 320H 400 4x3 158-203 2950

IS50 – 320H 100 2½ x 2 119-189 2800 IS80 – 320H 400 4x3 142-183 2800

IS50 – 320H 100 2½ x 2 102-166 2600 IS100 – 320H 400 5x4 123-158 2950

IS50 – 320H 100 2½ x 2 87-141 2400 IS100 – 320H 400 5x4 110-142 2800

IS50 – 320H 150 2½ x 2 177-296 3500 IS100 – 320H 400 5x4 98-172 2600

IS50 – 320H 150 2½ x 2 132-209 2950 IS100 – 320H 400 5x4 83-147 2400

IS50 – 320H 150 2½ x 2 118-188 2800 IS80 – 320H 450 4x3 157-203 2950

IS50 – 320H 150 2½ x 2 99-165 2600 IS80 – 320H 450 4x3 140-182 2800

IS50 – 320H 150 2½ x 2 84-140 2400 IS100 – 320H 450 5x4 122-158 2950

IS50 – 320H 200 2½ x 2 173-296 3500 IS100 – 320H 450 5x4 110-142 2800

IS50 – 320H 200 2½ x 2 127-209 2950 IS100 – 320H 450 5x4 98-172 2600

IS50 – 320H 200 2½ x 2 113-188 2800 IS100 – 320H 450 5x4 83-147 2400

IS65 – 320H 200 3 x 2½ 159-290 3500 IS80 – 320H 500 4x3 155-202 2950

IS65 – 320H 200 3 x 2½ 108-201 2950 IS80 – 320H 500 4x3 136-182 2800

IS65 – 320H 200 3 x 2½ 97-181 2800 IS100 – 320H 500 5x4 122-158 2950

IS65 – 320H 200 3 x 2½ 104-158 2600 IS100 – 320H 500 5x4 110-142 2800

IS65 – 320H 200 3 x 2½ 88-133 2400 IS100 – 320H 500 5x4 97-172 2600

IS65 – 320H 250 3 x 2½ 157-290 3500 IS100 – 320H 500 5x4 82-147 2400

IS65 – 320H 250 3 x 2½ 107-201 2950 IS100 – 320H 750 5x4 119-147 2950

IS65 – 320H 250 3 x 2½ 97-181 2800 IS100 – 320H 750 5x4 104-131 2800

IS65 – 320H 250 3 x 2½ 102-155 2600 IS100 – 320H 750 5x4 89-166 2600

IS65 – 320H 250 3 x 2½ 85-131 2400 IS100 - 260 750 5x4 113-139 2950

IS65 – 320H 300 3 x 2½ 155-289 3500 IS100 - 260 1000 5x4 104-131 2950

IS65 – 320H 300 3 x 2½ 107-201 2950

5
Characteristics

Discharge Wear Ring

Lantern Ring
Wear Ring
Gland Cover
Impeller
Shaft Sleeve

Casing Shaft

Suction

Bearing (Outboard)

Bearing (Inboard)

Description
- Discharge : Vertical Discharge on the center line
- Wear Ring : Bronze - Is standard for the certified ANSI pumps Radially split casing with flanged connections
- Bearing (Ind. & Out.) : Deep Grooved Ball Bearing
- Packing Gland : Immersion Graphite Rope
- Shaft : Stainless Steel - Sleeve shaft as standard for extended seal life
- Gland Cover : Bronze - to house a gland seal
- Lantern Ring : Bronze - to keep packing lubricated
- Impeller : Bronze - Enclosed impeller design ensures maximum efficiency
- Suction : Horizontal End Suction ANSI 150# or 300# flange drilling is available based on material selection
- Casing : Ductile Iron 65-45-12 - Heavy-duty power frame

6
Dimensions

Pump - Table of Dimension in (mm)

MODEL A B C D E F Ff G H L M N P Øj K

IS32 - 200 80 360 160 183.5 70 100 50 267 49 110 140 190 240 22.225 4.7x4.7x32

IS32 - 260 100 360 180 228 95 125 65 267 49 110 140 250 320 22.225 4.7x4.7x32

IS50 - 320H 125 470 225 285.6 95 125 65 342 79.4 110 140 280 345 28.575 6.35x6.35x44.5

IS65 - 320H 125 470 225 284 120 160 80 342 79.4 110 140 315 400 28.575 6.35x6.35x44.5

IS80 - 260 125 470 200 280 120 140 80 342 79.4 110 140 315 400 28.575 6.35x6.35x44.5

IS80 - 320H 125 470 250 317 120 160 80 342 79.4 110 140 315 400 28.575 6.35x6.35x44.5

IS100 - 260 140 470 225 280 120 160 80 342 79.4 110 140 315 400 28.575 6.35x6.35x44.5

IS100 - 320H 142 470 250 316 120 160 80 342 79.4 110 140 315 400 28.575 6.35x6.35x44.5

Flange - Table of Dimension in (mm)

Suction Discharge
Model
Ø ID Ø OD Ø dp Ø ID Ø OD Ø dp

4 holes Ø19 4 holes Ø16


IS32 – 200 50.8 152 32 117
On PCD 120 On PCD 90

4 holes Ø19 4 holes Ø16


IS32 – 260 50.8 152 32 117
On PCD 120 On PCD 90

4 holes Ø19 4 holes Ø19


IS50 – 320H 63.5 178 On PCD 133 50.8 152 On PCD 120

4 holes Ø19 4 holes Ø19


IS65 – 320H 76 190 63.5 178
On PCD 152 On PCD 140

8 holes Ø19 4 holes Ø19


IS80 – 260 101.6 228.6 76.2 190.5
On PCD 190 On PCD 152

8 holes Ø19 4 holes Ø19


IS80 - 320H 101.6 228.6 76.2 190.5
On PCD 190 On PCD 152

8 holes Ø19 8 holes Ø19


IS100 – 260 127 254 On PCD 190 101.6 228.6 On PCD 190

8 holes Ø19 8 holes Ø19


IS100 – 320H 127 228.6 101.6 228.6
On PCD 216 On PCD 190

7
Fire Pumps - Horizontal Split Case
Bristol Split Case Pump is a single stage, non-self-priming, centrifugal volute pump with radial suction and
discharge port. This pump has a horizontal pump shaft with the impeller placed in the middle of the shaft
and with self contained combination bearing housing and seal chamber on both sides of the impeller.
Without disturbing the motor or pipe-work, the split case construction enables the pump casing to be dis-
mantled in the horizontal plane along the drive shaft. Removal and dismantling of the internal pump parts
e.g. bearings, wear rings, impeller and shaft seal can then take place.

8
Features
- In line Pump
- Double Suction
- Low NPSH
- Low axial load on the shaft
- Double Volute
- Improved efficiency (Overall higher efficiency)
- Low radial load on the shaft
- Low axial and radial loads extends wear ring, seal and
- bearing life, minimize vibration and provides quit operation
- Easy service bearing and packing gland can be changed
- without removing the top casing half
- UL Certificate No. EX16089

Performance Range Material Construction


Capacity : From 300 GPM up to 1500 GPM Shaft : Stainless Steel
Head : From 50 MTR up to 150 MTR Casing : Ductile Iron
Impeller : Bronze
Shaft Seal : Packing Gland D - Immersion Graphite Rope

General Information for Centrifugal Fire Pumps, Split

Model Rated Capacity Size (In) Rated Net Pressure Approx Speed (RPM)
(GPM) Range (psi)

BSP-125-270 300 5x3 117 – 159 2950


BSP-125-270 400 5x3 115 – 157 2950
BSP-125-270 450 5x3 114 - 155 2950
BSP-125-270 500 5x3 112 - 154 2950
BSP-150-310 500 6x4 129 - 222 2950
BSP-150-310 750 6x4 125 - 223 2950
BSP-150-310 1000 6x4 117 - 218 2950
BSP-200-290 1000 8x5 155 – 194 2950
BSP-200-290 1250 8x5 147 – 191 2950
BSP-200-290 1500 8x5 138 - 184 2950

9
Characteristics
Lantern Ring Upper Casing

Flushing Pipe
Shaft Sleeve

Packing Gland
Bearing Housing

Pump Coupling

Shaft
Bearing

Bearing
Casing (Lower) Water Singer
Plug

Impeller Wearing Ring

Description
Casing - (Ductile Iron) - Upper and Lower half bolted and dowelled to provide perfect alignment. Upper half casing can be removed for
inspection, without disturbing bearings or alignment.

Shaft Sleeve - (Stainless Steel) - Protect the shaft against corrosion and wear, extends through gland for maximum shaft protection.

Impeller - (Bronze) - Enclosed, double suction, Cast in one-piece and balance to minimize the thrust and to ensure longer bearing life. Locked
in position by shaft sleeve.

Stuffing Box - (Ductile Iron) - Designed to accept packing with lantern ring. Internally drilled liquid passage in upper-half casing provides
lubrication to the packing area.

Shaft - (Stainless Steel) - Large - diameter, precision-machined, high strength steel shaft for maximum strength with minimum shaft deflection.

Bearking - (SKF) - High speed capability and low friction bearing.

Wear Ring - (Bronze) - A sacrificial component installed to inhibit fluid from re-circulating back to suction from the discharge.

Lantern Ring - (Stainless Steel) - A perforated hollow ring that receives relatively cool, clean liquid. Distribute uniformly around the shaft
to provide lubrication and cooling.

Packing Gland - (Immersion Graphite) - flexibility allows the shaft to run freely as well as leak proof.

Stuffing Box (Gland) - (Bronze) - to press the packing gland into the seal area through bolts.

Plug - (Stainless Steel).

Bearing Housing - (Cast Iron).

Flushing Pipe - (Stainless Steel) - Line from discharge of the pump and recirculated through an pressure regulating valve into the gland.

Water Singer - (Oil Resistant Rubber).

Pump Coupling (ASTM No.35).

10
Dimensions

Split Case - Table of Dimension in (mm)

Model A B C Cs E F G H L M N P Øj K

BSP-125-270 300 300 315 140 270 70 140 82 410 320 336 443 35 10x10x78

BSP-150-310 330 330 355 170 345 80 200 91.5 470 320 345 345 35 10x10x85

BSP-200-290 370 370 400 200 310 80 225 110 530 390 366 517.5 45 14x14x108

Flange - Table of Dimension in (mm)

Suction Discharge
Model
Ø ID Ø OD Ø dp Ø ID Ø OD Ø dp

8 holes Ø22 8 holes Ø22


BSP-125-270 143.8 279 90.7 210
on PCD 235 on PCD 168

12 holes Ø26 8 holes Ø22


BSP-150-310 170.7 318 116.1 254
on PCD 270 on PCD 200
12 holes Ø26 8 holes Ø22
BSP-200-290 221.5 381 on PCD 330 143.8 279 on PCD 235

11
Fire Pumps - Vertical Turbine
Bristol Vertical Turbine centrifugal pump is developed and fabricated by our company, according to
NFPA20. This pump is used for any underground water source where the water level is below the pump
suction, it’s Impeller remains submerged with the water tank at all times.

12
Where the fire protection water source is located below ground or deck level, the best technical pumping solution is the vertical suspended multi
stage turbine pump. With this type of unit the impellers are fully immersed in the water maintaining prime at all times. The pumps are driven by
vertical electric motors or by diesel engines through a right angle gearbox.

Features
- Performance and hydrostatic tests

- In compliance with NFPA 20, FM approved

- Materials of construction: cast iron, bronze fitted

- Sealing arrangement: packing with flushing

- Modular construction: assures complete flexibility in selecting a pump

- Pre-engineered standard components

- Space-saver design: requires minimum floor space

- Static suction lift: permissible by NFPA 20 where water source is


- located below ground

- Open line shaft: water-lubricated bowl and line-shaft bearings

- Stuffing Box (Gland) - (Bronze) - to press the packing gland into the seal area through bolts

- Bolted bowl: bowls and suction bell are bolted together, allowing easier disassembly

- Dynamic balanced impellers: secured to the shaft with steel locking collets

- Discharge gauge connection

Performance Range
Capacity : From 500 GPM up to 5000 GPM
Head : From 50 MTR up to 200 MTR

Material Construction
Shaft : Stainless Steel
Casing : Ductile Iron
Impeller : Bronze

13
Cross Sectional

Typical Services Gear Head

- Cooling Water
- Seawater and River Water Intake
- Industrial Process Pump
- Utility Circulating Water
Discharge Head “Ductile Iron”
- Condenser Circulating Water Pumps
- Fire Service Head Shaft Coupling - Stainless Steel
- Reclaimed Water
Discharge Pipe Assembly - AISI 1020

Bearing Spider w/ Bushing - ASTM A48

Column Pipe Assembly - AISI 1020

Shaft - Stainless Steel

Line Shaft Coupling - Stainless Steel

Bearing Spider w/ Bushing - ASTM A48

Column Pipe Assembly - AISI 1020

Upper Casing w/ Bushing - ASTM A48

Bushing - Vesconite Plastic

Shaft Sleeve - Stainless Steel

Casing Bowl - Cast Iron

Wearing Ring - Stainless Steel

Impeller - Bronze

Suction Assembly - Carbon Steel

Strainer - Stainless Steel

Performance Parameters of Table

No. Type Capacity (m3 /h) Speed Pressure (Kpa (psi))


(GPM)
1 BVP 350 115 (500) 1490 310 - 1605 (45 - 233)
2 BVP 350 170 (750) 1490 285 - 1480 (41 - 215)
3 BVP 350 170 (750) 1790 450 - 1560 (65 - 226)
4 BVP 350 227 (1000) 1790 405 - 1427 (59 - 208)
5 BVP 450 285 (1250) 1490 295 - 1545 (43 - 224)
6 BVP 400 285 (1250) 1490 365 - 1510 (53 - 219)
7 BVP 450 340 (1500) 1490 285 - 1505 (41 - 215)
8 BVP 400 340 (1500) 1490 330 - 1570 (48 - 228)
9 BVP 450 340 (1500) 1790 425 - 1700 (62 - 248)
10 BVP 400 340 (1500) 1790 530 - 1590 (77 - 231)
11 BVP 450 1490 275 - 1415 (40 - 205)
454 (2000)
12 BVP 450 454 (2000) 1790 405 - 1620 (59 - 236)
13 BVP 500 568 (2500) 1490 750 - 1500 (109 - 218)
14 BVP 650 680 (3000) 1490 635 - 1270 (92 - 184)
15 BVP 650 795 (3500) 1490 605 - 1210 (88 - 176)
16 BVP 650 908 (4000) 1490 600 - 1200 (87 - 174)

17 BVP 650 1022 (4500) 1490 580 - 1740 (84 - 252)


18 BVP 650 1135 (5000) 1490 560 - 1680 (81 - 243)

14

You might also like