Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

5070 - 1.6-1.7 AST Sample Tubes

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Sample Tubes AST

for sample probes series ASP

Application
These sample tubes are used in combination with the Ankersmid ASP probes
in order to sample the gas in the optimal section of the gas-stream. For a
typical installation of the probe-tip, a position in the middle third of the gas
stream is advised.
For dust concentrations higher than 2g/m, we advise fitting a pre-filter in
combination with an extension tube.
Description
Different solutions for different applications:

Used for dust loading


up to 2g/m3
Sampling after wet scrubber
up to 90C
Sampling gases up to max.
1400C
Different materials
Available in lengths up to
2500mm, others in request

Maximum sample tube temperature is depending on the horizontal length inside this temperature zone.
Application

Tube type

After wet scrubber


or high dew point

ADT 080
(Demistor tube)

Temp < 150C

Max. T
[C]

Material

Connection

Outer
diameter

90C

PTFE

G o

40-70

AST 411-412- 413

150C

PTFE

G o

22

Temp < 600C

AST 051- 404

600C

SS316

G o

22

Temp < 900C

AST 431-432-433-434

900C

Hastelloy C

Temp < 1400C

AST 435

HCl or high
corrosive gas

AST 421-422-423-424

G o

22

1400C

Kanthal

G o

20

450C

Titanium

G o

22

Ankersmid Products, http://www.ankersmidsampling.com, Ankersmid Sampling products manufacturing


Neerlandweg 22, 2610 Wilrijk, Belgium Tel.: +32(0)3/820.80.00 Fax: +32(0)3/230.98.58

Electrically heated sample tube


AST 05x, AST 10x, AST 15x, AST 20x

Application
The electrically heated Ankersmid sample probe tube AST 05x-10x15x-20x are used in extractive sampling systems to avoid cooling and
condensation of the sample.
Condensation, in combination with a high dust load, can result in blockage
of the probe. This is to be strictly avoided as sample gases may be
absorbed into the condensate after cooling and will be undetectable. An
extra stainless filter can be mounted on top of the tube in case of very high
dust levels (> 10 g/m).
Description

Different lengths available

This electrically heated sample tube is available in 4 standard lengths:


0.5, 1, 1.5 and 2.0 meter (other lengths on request).
As for all Ankersmid probes, the standard flange is a DN65 PN6.
Adapter flanges for most common process connections can be provided if
required.
If needed, it is possible to affix a non-heating sample probe or pre-filter to
the tip of the heated tube.
Inside the sample tube a thermocouple type J (Fe-CuNi) is integrated. As a
standard it is installed in combination with the digital controller, the user has
a freely programmable set point and alarm.

Completely heated sample


tube
Digital controller
Easy mounting
Optional: Modbus/RS485

Optional available is a 2-way Modbus/ RS485 communication that combines


signals from all installed Ankersmid controllers, so that digital communication
with the control room is possible.
Dimensions

Ankersmid Products, http://www.ankersmidsampling.com, Ankersmid Sampling products manufacturing


Neerlandweg 22, 2610 Wilrijk, Belgium Tel.: +32(0)3/820.80.00 Fax: +32(0)3/230.98.58

Technical data

Series AST Type

AST05x

AST10x

AST15x

AST20x

Temperature sensor & controller


(additional part number)
AST 001

Incorporated capillary temperature controller

AST 002

Temperature sensor thermo-couple type J (Fe-CuNi)

AST 003

Temperature sensor thermo-couple type K (NiCr-Ni)


Temperature sensor thermo-couple type J (Fe-CuNi),

AST 004

including integrated electronic controller with high/low alarm


Temperature sensor thermo-couple type K (NiCr-Ni),

AST 005

including integrated electronic controller with high/low alarm

RS 485 / Modbus interface


Probe tube length L1
Sample temperature max.
Operating temperature max.
(pre-adjusted at 180C)

Optional
500mm

1000mm

1500mm

2000mm

500C

500C

450C

400C

200C

200C

200C

200C

Pre-filter

Optional

Sample gas inlet connection

G3/4"i

Dust loading

max. 2 g/m3

Probe tube volume

200ml/m

Sample pressure max.

5 bar g

Ambient temperature

-20C to +70C

Storage temperature

-30C to +70C

Ready for operation

Approx. 0,5h

Power supply
Electrical connection
Electrical standard
Degree of protection
Mounting flange
Material of gas wetted parts

230VAC, 500W

230VAC, 800W

230VAC, 1200W

230VAC, 1500W

115VAC, 500W

115VAC, 800W

115VAC, 1200W

115VAC, 1500W

2 x 2.5mm + 2.5mm
EN 61010, EN60519-1
IP54 EN 60529
DN65 PN6
Stainless steel 316

Ankersmid Products, http://www.ankersmidsampling.com, Ankersmid Sampling products manufacturing


Neerlandweg 22, 2610 Wilrijk, Belgium Tel.: +32(0)3/820.80.00 Fax: +32(0)3/230.98.58

You might also like