200watt Active Load Unit
200watt Active Load Unit
200watt Active Load Unit
Description 2
Operation 2
Specification 2
Schematic 3
Mechanical Drawings 5
BOM 9
Construction Techniques and Suggestions 9
Addendum 10
Table of Figures
1. Description
1.1. The Dummy Load Unit is an active power supply load that can be adjusted with a
multi-turn control. The DLU is a building block that can be replicated to any level as
required. Multiple units can be paralleled for larger current draws. Each unit is
electrically isolated so they can be arranged to test +- power supplies.
1.2. A chassis containing 4 individual units is a general bench device that can be used
during power supply testing and evaluation. This chassis construction as well as the
DLU is described in this engineering note.
2. Operation
2.1. The DLU is a very simple device, connect the supply to the studs on the back of the
chassis and control the current level with the pot on the front. The front panel meter
provides visual feedback of the load current.
2.2. Each load unit is capable of dissipating a minimum 200Watts of power. Each unit is
however limited to 20Amps of current. If the load is 5V then 20Amps of current can be
drawn but only 100Watts will be dissipated. If the voltage is 10V then 20Amps can be
drawn and 200Watts will be dissipated. At 15V approximately 13Amps can be handled
and so on.
2.3. Each unit is self-contained, except for the cooling fans; therefore they can be
connected as needed to provide special loading. That is they may be used on +/supplies or paralleled to provide larger current loading.
2.4. The front panel holds an Ammeter, current control knob, momentary zero button
and a 10-20 Amp full-scale range switch for each unit.
2.5. The momentary zero button is useful when testing power supplies that fold-back or
when close to the trip point. The current can be lowered slightly and the zero button
pressed to restore the supply without turning the current adjustment all the way down.
Since the load is self powered some instablities may occur if the supply folds back
during testing.
2.6. The range switch is used to set the full scale current to either 10 or 20Amps.
2.7. The chassis back panel contains stud connections for each load unit. Polarity should
be observed to ensure proper operation. If the connections are reverse the unit will not
draw any current. The positive terminal is on top.
3. Specification
3.1. Current Range: 20mA-10Amps / 20mA-20Amps set by the range switch on the
front panel and controlled with the multi-turn pot. Note that the current does not go all
the way to zero because there is a small quiescent current needed to operate the IC.
3.2. Voltage Range: ~3 to 40Volts with 500VDC common mode isolation between DLU
and chassis ground.
3.3. Power dissipation: 200W per module minimum, 800W per chassis assembly. The
DLU transistor is rated at 300W when the case is at 25C and derates linearly to 0Watts
at 200C (see figure 1). The transistor case may operate 50C above ambient at
200Watts.
4. Schematic
4.1. This design is adapted from Toffoli, Tommaso "Self-Powered Dummy load Checks
Out multiple-Output Power Supplies" ELECTRONIC DESIGN 'Ideas For Design' April
17, 2000, pg. 118.
4.2. The circuit is a simple series pass regulator using an OpAmp that contains a built-in
voltage reference. The desired portion of the reference is compared with the output
voltage across the shunt to provide the constant current load. The components
connected to the base of the power transistor add stability and thermo protection.
4.3. A small PC board mounts directly to the transistor and holds most of the
components.
5. Mechanical Drawings
5.1. For the DLU to operate in a useful manner an efficient method to eliminate the
dissipated power must be employed. A special copper heat sink spreads the heat to a
larger set of aluminum extrusions allowing heat dissipation to the air. The idea is to
keep the temperature rise on the transistor case to a minimum allowing the maximum
power dissipation.
Figure 3 Aluminum Extrusions The extrusion is drilled for mounting the copper heat
spreader, thermo-switch and chassis mounting.
Figure 4 Copper Heat Spreader The copper spreader holds the pass transistor and
connects to two aluminum extrusions. It serves as the base for the regulator assembly.
Figure 5 Regulator Assembly with Extrusions Bottom View The printed circuit board
mounts directly to the transistor and shunt.
Figure 6 Regulator Assembly Top View This view shows the thermo-switch mounting
and the pass transistor buried in the pocket of the heat sink.
6. BOM
Bill Of
September
12:00:00 8 Units
Materials 3,2002
2 Chassis
Quantity
Reference
Part
Stockroom
Unit Cost
Description Items
A1
LM10
C1,C2,C3
150uF
Electrolytic
Item
Total
Cost
Unit
Regulator
OpAmp
with voltage LM10CN $2.66 $21.28
reference
$0.50 $12.00
M1
0-25A
Q1
MJ11030
R1
R1,R2
R3
R6,R3
R4
10
R5
11
SW1
12
S1
13
TH1
14
15
16
17
18
19
Ampmeter
Power
Transistor
1Meg
5% 1/4W
Multi-Turn
10K
Pot
160
1% 1/4
wire wound
1
1/4W
1.2K
5% 1/4W
Shunt
0.01
Resistor
Momentary
Zero
push button
Range
SW SPDT_0
switch
Thermo
150F
Switch
Aluminum
special
Heatsink
Copper
special
heatsink
Model
1227
$2.03 $16.24
$2.75 $44.00
$7.00 $56.00
$5.00 $40.00
$10.00 $80.00
$0.01 $0.08
1224107500
12266-32 x 1/2" S.S. Screw
256000
Brass Hex
1/4-28
Nut
Brass Hex
6-32
Nut
6-32
$15.00 $120.00
Brass Screw
$0.01 $0.24
$0.10 $0.80
$0.10 $0.80
$0.02 $0.80
Chassis
Assembly
18
19
20
21
22
23
24
MT1,12
1/4-20 x
3/4"
Brass
hexhead
bolts
1224117000
1175051000
1175Guard
Fan Guard
055000
Fan cord & 1175Cord
plug
060000
Chassis Top 1775Top/Bottom
& Bottom 281000
Chassis
1775Side
Sides
257500
Chassis
1775Front
Front
240500
Fan
Fan
$0.11 $1.76
$9.01 $36.04
$1.16 $4.64
$1.15 $4.60
$33.68 $134.72
$31.05 $124.20
$15.60 $31.20
25
Back
26
terminal
27
terminal
28
29
30
31
32
33
16
NT1,24
34
16
NW1,24
35
F4
Chassis
Back
1/4-10Ga
Ring
Tongue
#6-10Ga
Ring
Tongue
1775244500
$11.65 $23.30
1110428000
$0.17 $1.36
1110426500
$0.13 $0.26
Belleville
Washer
Belleville
#8 washer
Washer
12268-32 x 1/2" S.S. Screw
161000
Nylon Hex 12146-32
Nut
050000
Nylon
12306-32 x 1/2"
Screw
100000
1/4-20 nut Brass nuts
Nylon Flat 12221/4" washer
Washer
026000
Plug and
1170acplug
Cord
134000
#6 washer
$0.00
$0.00
$0.01 $0.12
$0.04 $0.64
$0.08 $1.28
$0.00
$0.03 $0.96
$3.25 $6.50
$1,023.74
7.2.1. Each Dummy Load Unit is loosely mounted inside the chassis. The
units merely sit on nylon screws that hold them in place when the top
and bottom covers are installed.
7.3. Chassis Cooling
7.3.1. A cooling channel is required to keep airflow over the heatsinks.
The front half and rear half act independently. This is accomplished with
simple G10 spacers.
8. Addendum
8.1. A few 'good' modifications have been added to the circuit to improve some
areas of failure and instability.
8.2. Added a 1 Meg resistor to the wiper of the pot to keep the output from maxing
out if the wiper contact opens.
8.3. Added an isolating resistor and filter capacitor to the OpAmp supply rail pin.
8.4. Added a series power Schottky diode to the circuit to prevent current flow
when the unit is connected backwards.
8.5. The OpAmp is socketed for solder free replacement.
8.6. Complete mechanical drawings are available for all the components associated
with this design.