For Battened Columns For Strength Cal 10% Increase in The KL/R
For Battened Columns For Strength Cal 10% Increase in The KL/R
For Battened Columns For Strength Cal 10% Increase in The KL/R
300 mm
single section details
A
bf
tf
Ixx
Iyy
4564 mm2
90 mm
13.6 mm
63626000 mm4
3108000 mm4
Cyy
rxx
ryy
gross area
flange width
flange thk
23.6 mm
118.1 mm
26.1 mm
4000 mm
9128 mm2
127252000 mm4
152053691 mm4
118.07134 mm
129.065648 mm
OK
118.07134 mm
33.8778233
for battened columns for strength cal 10% increase in the kl/r
i.e for kl/r 33.8778233
section capacity
ac
1296.176 KN
142 N/mm2
BATTEN DESIGN
1
Ryy
>
Rxx
OK
SLENDERNESS RATIO
KL/R
33.87782
2
618.9478 mm
NO OF DIVISIONS REQUIRED
EXACT C/C SPACING
571.429 mm
VT
32.4044 KN
VB
33.06571 KN
M
3
SHEAR IN BATTEN
4.6292 KNm
MOMENT IN BATTEN
252.8
say
275 mm
189.6
say
200 mm
say
6 mm
THK
6 mm
4.6292 KNm
Mr
VB
VBr
6 KNm
33.0657143 KN
120 KN
WELDING
MOMENT IN BATTEN
>
OK
SHEAR IN BATTEN
>
VB
OK
6 mm thk
36.08723 mm
<
200 mm thk
HENCE
OK