Precast Concrete PDF
Precast Concrete PDF
Precast Concrete PDF
DAYTONSUPERIOR.COM
HANDBOOK
11/12
Fleet-Lift System
General and
Technical
Information
Utility Anchor
Lifting System
Lifting/Handling
Inserts
and Accessories
Structural
Connectors
Miscellaneous
Connection Inserts
Sandwich Panel
Connectors
Miscellaneous
Products
General and
Technical
Information
Swift Lift System
Fleet-Lift System
Utility Anchor
Lifting System
Lifting/Handling
Inserts
and Accessories
Structural
Connectors
Miscellaneous
Sandwich Panel
Connection Inserts
Connectors
Miscellaneous Connection
Inserts..................................123
Thermoform Vacuum-Formed
Formliners..................................... 136
Rustication Strips............................. 137
Rustications, Chamfers and Coverers.... 138
Miscellaneous
Products
11/12
Safety Factors
A safety factor applied to a particular product is a variable, depending on the degree of hazard or risk involved in the application
of that product. In precast concrete construction various conditions can often increase loading, as well as the degree of risk
involved. Adhesion of the concrete element to the form, jerking of the crane during lifting, use of a crane not adequate for the
job, bouncing the precast element after it has been lifted, handling the element more than anticipated, transporting over rough
surfaces, etc., all have high risk factors. In cases such as these, the user should increase the safety factor accordingly.
Dayton Superior recommends that the following minimum safety factors be used when determining a products safe
working load and that the provisions of OSHA (Occupational Safety and Health Administration Act, Part 1910) be strictly
followed when considering safety factors:
If a different safety factor from one shown in this handbook is required for any reason, the following equation is used to
increase or reduce a safe working load:
Safety Factor
2 to 1
Brace Anchors
3 to 1
Permanent Connections
4 to 1
5 to 1
Warning: New safe working load must not exceed the products mechanical capacity divided by the new safety factor.
11/12
General and
Technical
Information
General and
Technical
Information
11/12
l
= Reduction factor for use with lightweight concrete, see "Safe Working Load Reduction Factors for Inserts Used in
Lightweight Concrete" next page;
jc,N
Surface
Area of
Theoretical
Shear Cone
Concrete
Surface
hef
35
dh
Pconcrete
Illustration A1
For inserts located near an edge
preventing development of a
full shear cone please contact
a Dayton Superior Technical
Services Department for insert
capabilities.
Surface Area
of Theoretical
Shear Cone
Concrete
Surface
hef
35
dh
Illustration A2
When the value of Pconcrete exceeds the ultimate mechanical tensile capacity of the insert, the insert will fail. It is apparent
that the shear cone becomes larger as the insert is embedded deeper in the concrete. Sufficient depth of embedment
would theoretically permit the development of the full ultimate strength of the insert.
Deep embedment is generally considered impractical for precast concrete, but some types of anchors depend upon this
principle for their effectiveness. The Dayton Superior F1 Screw Anchor and P52 Swift Lift Anchor are two examples.
All other factors being equal, depth of embedment has more effect on the strength of a concrete insert than any other
single factor. A concrete insert under tensile loading to failure will fail in one of four ways:
1. The entire insert may pull out of the concrete with little apparent damage to the concrete (see Illustration B). Such failures
are rare and, when they do occur, are the result of bond failure between the concrete and insert. These failures usually
occur in green and/or low strength concrete.
2. The entire insert may pull out of the concrete bringing with it a cone of concrete having its apex slightly above the most
deeply embedded part of the insert (see Illustration C). Such failures usually occur in relatively low strength concrete in
which the tensile strength of the shear cone surrounding the insert is not as great as the strength of the insert itself.
3. A failure may also occur through breakage of the insert. Coil type inserts will usually fail at a point just below the helically
wound wire coil. A small cone of concrete will usually be pulled out of the concrete surface (see Illustration D). This cone
will have its apex at a point just below the coil. The base diameter will be approximately twice the cone height. Swift Lift
Inserts will fail by fracturing of the shaft diameter of the insert (see Illustration E).
NOTE: The above formulas have been applied to all coil and ferrule insert charts in this handbook. All manufactured
lifting systems (Swift Lift, Fleet Lift, Utility Anchor) utilize test results.
These failures occur in high strength concrete when an insert is loaded beyond the ultimate strength of the insert. Failures
of this type are due to a definite overload being applied to the inserts. Such failures can be prevented by choosing inserts
of capacity suitable to job conditions.
11/12
General and
Technical
Information
General and
Technical
Information
4. When bolting coil type inserts, the bolt should always extend the proper amount beyond the bottom of the insert coil.
Failure to do this causes the entire bolt load to be transferred to fewer turns of the coil, causing an increased load per
weld contact point. The coil will then unwind, much like a corkscrew, resulting in a failure (see Illustration F).
P
P
P
Illustration B
Illustration C
Illustration D
Illustration E
Illustration F
Safe Working Load Reduction Factors for Inserts Used in Lightweight Concrete
Insert safe working loads, shown in this handbook, were derived from analysis and testing of Dayton Superior inserts
used in normal weight (150 pcf) concrete. The safe working load of the insert is dependent upon the compressive
strength of the concrete in which it is embedded. Therefore, when Dayton Superior inserts are used in lightweight
concrete precast elements, the safe working load of the inserts must be recalculated to compensate for the reduction
in concrete density. Multiply the published safe working loads by a reduction factor, shown in the table, to obtain the
corrected safe working load. The table displays the various reduction factors recommended by Dayton Superior for
lightweight concrete.
Concrete Type
Normal Weight
1.0
0.85
0.75
Verify by Testing
Interested readers are referred to Section 11.2 of the American Concrete Institutes Building Code Requirements for Reinforced Concrete (ACI 318) for additional information.
Location of Insert
Embedment of inserts closer to an edge than the minimum edge distances, shown in this handbook, will greatly reduce
the effective area of the resisting concrete shear cone and will reduce the inserts tension safe working load. The shaded
11/12
area of the shear cone, shown in the illustrations below, indicates the extent the shear cone area is reduced. Tension
safe working loads of inserts used in thin wall conditions or near a free edge or corner must, therefore, be reduced in
proportion to the reduction in effective shear cone area (see Illustrations G & H).
Another condition frequently encountered is that of an insert embedded near a free edge or corner and loaded in a
transverse direction to the axis of the bolt, toward the free edge of the concrete. Contact Dayton Superior Technical
Assistance for safe working loads of inserts used in this type of condition.
P
Tension
or P
Shear
P
D
de
de
Illustration G
Illustration H
Insert Placement
Inserts must be placed accurately. An inserts safe working load decreases sharply if it is not perpendicular to the bearing
surface, or if it is not in line with the applied force.
Inserts lend themselves to being located and held correctly (by bolts and brackets or by tying to the reinforcing steel)
before the casting operation begins. Failure to achieve proper insert placement is careless field installation. It is also
important to place inserts so that the depth of thread is constant for the same size insert throughout a job. This eliminates
potential bolt engagement mistakes by the erection crew. Inserts should always be kept clean of dirt, ice or other objects
that will interfere with attachment of the lifting hardware.
Note: For ferrule inserts, establish this dimension and
maintain for all similar sized inserts on a project. For coil
inserts, the coil bolt must penetrate through the insert coil
by the proper amount.
1/2"
Minimum
to Develop
Insert Safe
Working
Load
90
Wrong
(Too High)
Wrong
Wrong
(Angled)
(Too Low)
Correct
Illustration I
11/12
General and
Technical
Information
General and
Technical
Information
1e
1.5
c7
nd o nd o fc (c al)
= Cracked concrete factor: 1.0 for cracked concrete and 1.4 if uncracked.
l e
do
fc
ca1
For conditions where a corner or thickness in direction of embedment is less than 1.5 x ca1 or an adjacent insert is closer
than 3 x ca1 contact Dayton Superior Technical Services Department for insert capacities.
For cases where increased shear capacity is required, the addition of pre-formed shear bars over the top of the insert will
greatly increase the distribution of the load. Shear bars, when used, must be in solid contact with the insert to be effective.
If accurate capacities of inserts are desired, several inserts with shear bars should be tested in job size panels.
ca1
P
Point X
Point X
Shaded areas indicate probable tensile stress pattern in
concrete near edge insert subject to load P.
Illustration L
( fF ) / ( fF ) /
5
3 +
1.0
Where:
fv
Fv
ft
Ft
11/12
Torque-Tension Relationship
For some types of bolted connections, it may be desirable to have a minimum clamping force (tension load). Due to the
many variables associated with tightening bolted connections, it is possible to experience as much as a 25% variation in
the amount of clamping force applied to similar connections receiving identical torque.
The following equation is taken from Fasteners Standards Sixth Edition, published by Industrial Fasteners Institute, East
Ohio Building, 1717 East 9th Street, Suite 1105, Cleveland, Ohio 44114-2879. It is used to provide an estimate of the
torque required to apply a given preload to a bolted connection.
T = KDP
12
The torque coefficient will vary from the values, shown above, when bolts have been plated, greased or coated with other
types of lubricant.
Tension
Shear
Tension
Shear
1/4" 20
625 lbs.
350 lbs.
1,250 lbs.
725 lbs.
3/8" 16
1,500 lbs.
900 lbs.
3,100 lbs.
1,800 lbs.
1/2" 13
2,800 lbs.
1,700 lbs.
5,600 lbs.
3,400 lbs.
5/8" 11
4,500 lbs.
2,700 lbs.
9,000 lbs.
5,400 lbs.
3/4" 10
6,600 lbs.
4,000 lbs.
13,300 lbs.
8,100 lbs.
7/8" 9
9,200 lbs.
5,600 lbs.
18,400 lbs.
11,300 lbs.
1" 8
12,100 lbs.
7,400 lbs.
24,200 lbs.
14,900 lbs.
1-1/8" 7
15,200 lbs.
9,400 lbs.
26,700 lbs.
16,400 lbs.
1-1/4" 7
19,300 lbs.
12,000 lbs.
33,900 lbs.
21,000 lbs.
1-1/2" 6
28,100 lbs.
17,500 lbs.
49,100 lbs.
30,600 lbs.
Safe working loads shown provide a factor of safety of approximately 3 to 1 (ultimate to Safe Working Load). Shear
Safe Working Load assumes that the threads are included in the shear plane. 1/4"20, 3/8"16 and 1/2"13 bolts are not
recommended for use as structural fasteners. For combined shear/tension interaction, refer to page 12.
Condition of Loadings
All safe working loads shown in this handbook are for static load conditions only. If dynamic forces or impact loading
conditions are anticipated, the safe working load must be reduced accordingly.
Care must be exercised to see that all inserts and hardware units are properly aligned, all lifting plates and bolts properly
secured, all rigging is equalized, and properly sized crane cables utilized.
Warning: When in doubt about the proper use or installation of a Dayton Superior precast product, contact Dayton
Superior for clarification. Failure to do so may result in safety hazards, exposing workers in the vicinity of the precast yard
or job site to the possibility of injury or death.
11/12
General and
Technical
Information
General and
Technical
Information
Material
Approximate Thickness
Wire
.002"
Wire
.003"
Wire
.004"
Steel or Plate
.002"
Steel or Plate
.003"
Steel or Plate
.125" or thicker
.004"
Class
Approximate Thickness
Castings
.004"
B1
.004"
B2
.003"
Exposure
SC-4
Very Severe
.001"
SC-3
Severe
.0005"
SC-2
Moderate
.0003"
SC-1
Mild
.0002"
Approximate Thickness
As Plated
Colored Chromate
Colorless Chromate
Phosphate
11/12
Condition of Loading
The preceding paragraphs have been devoted to the behavior of concrete inserts under straight tensile loading. Obviously,
there are many conditions of loading other than direct tension. Most situations will require consideration of shearing
and/or bending forces applied to the insert through the anchor bolt or other connecting hardware. A common condition
occurs when a precast concrete element is lifted by means of inserts in each end without a spreader bar (see IllustrationJ).
When a load P is carried by only two inserts, the vertical reaction R that must be carried by each insert is 1/2 P. There is
also an additional vertical force V, that must be added to R, that is caused by the horizontal component H of force T.
The horizontal force H that is exerted on the insert and on the concrete surrounding it is proportional to the total load and
to the angle a included between the sling and the surface of the concrete. This force may be expressed by the equation:
H = P (cot a).
2
The magnitude of the tensile force on the sling is proportional to the total load and to the angle a. This force may be
expressed by the equation:
T= P
2 sin a .
As angle a decreases, the values of H and T increase. As angle a approaches 0, the magnitude of both H and T approaches
infinity. Conversely, as angle a increases, the values of H and T decrease, so that as angle a approaches 90, force T
approaches the value of 1/2 P and force H approaches 0.
T
See Detail A
R = 1/2 P
Illustration J
Detail A
It is readily apparent that the use of long slings will greatly reduce destructive forces on the slings, the lifting hardware and
on the precast element itself.
d
H
e
SHEAR
C
(d - x)
Illustration K
V
11/12
General and
Technical
Information
General and
Technical
Information
The only value on the right hand side of this equation that cannot be definitely determined is dimension x. This distance is
determined by the compressive stress pattern under the lifting plate.
If the pattern is triangular:
5. Cmax = ( 1 f'c) (db) and x = d.
2
3
If the pattern is rectangular
6. Cmax = (f'c) (db) and x = d.
2
More probably, the pattern is a trapezoidal compromise and:
7. Cmax = (.85 f'c) (db) and x = 5/12 d.
For any given lifting plate, the value of Cmax will be limited by f'c or by Vmax which is the pull out strength of the insert, since, by
equation (2) V = C.
Test results indicate that the assumption of a rectangular stress pattern is valid and conservative for most conditions.
2 (e) (H)
8. Equation (4) then becomes V =
.
d
Values 2e
for Dayton Superior Lifting Hardware are shown in the Table below.
d
Warning: Lifting plates or other attachment hardware must be bolted
tightly to the concrete, and bolt holes in the plate must not be excessively
larger than the anchor bolt. Disregard for these precautions can cause bolt
bending, excessive unbalanced loading on the insert and possibly a premature failure.
Applying equation (8) to a specific situation: Assume that a B18 " x 9"
Single Flared Coil Loop Insert is being used (safe working load is 4,750lbs.)
together with a T12 Swivel Lifting Plate in such a manner that the vertical
component of the load on the insert is 4,500lbs. and the horizontal
component of load on the insert is 1,000lbs.
(e) (H)
Using equation (8), V = 2
, and values of 2e
d d
from the table, V = .65 x 1000lbs. or 650lbs. of additional pull on the
insert caused by the horizontal component. Adding: 4,500lbs. +
650lbs. = 5,150lbs. This exceeds the rated load of the insert and
requires that a stronger insert be chosen.
10
Bolt Diameter
2e
d
T8
1", 1-1/4" or
1-1/2"
2.00
T12
3/4"
0.65
T12
1"
0.67
T12H
1-1/4"
0.83
T12H
1-1/2"
0.83
T26H
3/4"
1.46
T26
1"
1.00
T26H
1"
1.46
T26
1-1/2
0.71
T27
3/4" or 1"
3.00
11/12
P2
P1
Warning: Avoid the use of Fleet Angles greater than 120 as their
use can overload and damage anchors causing a premature failure
resulting in property damage, serious personal injury or death.
P
Fleet
Angle
0
Multiplication
Factor
F
1.00
16
1.01
30
1.04
45
1.08
60
1.16
75
1.26
0 = Fleet angle
90
1.41
105
1.64
120
2.00
= Multiplication factor
PxF
P1 = P2
P1 = P2
= P x F/2 anchors
P1
P2
P1 = P x b/a + b
P2 = P x a/a + b
Resultant
Load on
Anchor
Varies
Reaction of
Anchor
Right
Wrong
11/12
11
General and
Technical
Information
General and
Technical
Information
120
120
120
Illustration R1
3 anchors will carry load when used on round precast concrete elements with the anchors spaced
120 apart.
2 anchors will carry load when used on square or
rectangular precast elements.
Illustration R4
Illustration R2
4 anchors will carry load when using 4 individual slings in conjunction with
the Dayton Superior T46 Spreader Beam with Twin 7-1/2-ton Shackles.
Illustration R3
Illustration R5
The above assumes that the anchors are spaced equally about the center of gravity of the precast concrete element and
that the center of lift is directly above the center of gravity. Failure to locate the center of lift directly over the center of
gravity will cause the precast element to tilt.
12
11/12
9) Panel thickness,
10) Edge distance (thin wall, free edge or shear loading conditions).
Determining the dead load weight of a precast concrete section is straight forward, although serious errors are easy to
make, such as: 1. Miscalculations involving symmetrical panels; 2. Forgetting that a panel is normal weight concrete and
using the unit weights of lightweight concrete and 3. Neglecting adhesion to the form.
In addition, transporting the panel in the storage yard over bumpy conditions introduces dynamic loads that must also be
anticipated. Removing the precast element from the form can induce forces that, in effect, increase the dead load weight at
a critical time, when the concrete compressive strength is at its lowest value. Depending on the quality of release agent used,
the following adhesion loads should be considered when determining the additional weight of the concrete element:
Concrete Forms
up to 20 Ibs./sq. ft.
Steel Forms
up to 25 Ibs./sq. ft.
Plywood Forms
(Flat Surface)
up to 50 Ibs./sq. ft.
Plywood Forms
(Ribbed Surface)
up to 75 Ibs./sq. ft.
The type of concrete used determines the unit weight characteristics and the resultant ability of the concrete to resist the
pullout forces introduced by the insert. See page 8 for the proper load reduction factors that must be applied to insert safe
working loads when an insert is embedded in lightweight concrete.
Consideration must also be given to dynamic loads that can occur in the plant, in the storage yard, as well as during
transportation to the job site and during erection. It is suggested that a detailed study be made of the various handling,
storage, transporting and erection forces. The user is cautioned to be aware of these additional forces and to give due
consideration to their effect on the inserts safe working load.
Example One
Select the proper length and capacity of insert based on the use of a spreader
frame, as shown below, that will allow equal loading on all four inserts. Assume
normal weight concrete having a compressive strength of 2,700 psi at initial lift.
Dead Load Weight = 15' x 8' x 12.5 Ibs./sq. ft. x 6" = 9,000 Ibs.
Adhesion to Form = 15' x 8' x 75 Ibs./sq. ft. =
(Ribbed Surface)
18,000 Ibs.
= 4,500 Ibs./insert
"
18,000 Ibs.
4 inserts
'-0
90
6"
15
9,000 Ibs.
8'-0"
Illustration M
11/12
13
General and
Technical
Information
Example Two
Select the proper length and capacity of insert, based on the use of a spreader beam and slings at a 60 angle with the top
surface of the precast section. Assume normal weight concrete having a compressive strength of 4,000 psi at initial lift and
the use of 1" diameter T12 Swivel Lifting Plates.
Dead Load Weight = 20' x 7' x 12.5 Ibs./sq. ft. x 6" = 10,500 Ibs.
Adhesion to Form = 20' x 7' x 25 Ibs./sq. ft. =
3,500 Ibs.
Effective Weight of Panel =
14,000 Ibs.
Therefore, the vertical reaction that must be carried by each
14,000lbs.
insert =
= 3,500lbs.
4 inserts
= 3,500 Ibs. x cot. 60 = 3,500 Ibs. x .578 or
= 2,023 Ibs./insert
2e
=
x 2,023 Ibs. = .65 x 2,023 or
d
V
V = 1,315 Ibs./insert
Required Insert Capacity = 3,500 Ibs. + 1,315 Ibs.
= 4,815 Ibs./insert
Maximum Insert Height = 5"
Select the following insert: F56 Expanded Coil Insert,
1" diameter x 5-1/2" long,
6,250 Ibs. Safe Working Load.
Check combined tension and shear as follows:
6"
'-0
"
H
H
60
20
7'-0"
Illustration N
5/3
5/3 = .80. Since this is less than 1.0, the insert which was
( 4,815lbs.
( 2,023lbs.
4,800lbs. )
selected is suitable for use.
6,250lbs. )
+
Example Three
'-0
"
Select the proper length and capacity of an insert based on the use of a four sling lift (see warning note below) with cables
at a 60 angle to the top surface of the precast section. Assume lightweight concrete having a unit weight of 115lbs./cu.
ft., a compressive strength at initial lift of 4,000 psi and the use of 1-1/2" diameter T12 Swivel Lift Plates.
10
General and
Technical
Information
As the reduced Safe Working Load is greater than the 10,275 Ibs. Ioad required, it appears this insert is suitable for use.
However, combined shear and tension must be checked as follows:
5/3
4,009lbs. 5/3
(10,275lbs.
( 11,750lbs.
) = 1.01, which means this insert must be replaced with a stronger insert.
11,375lbs.)
+
Warning: When individual slings are used, any two inserts must be capable of lifting/handling the precast section. This is
due to unequal sling lengths and the resulting loads that are transferred to the shorter slings. In this application, only two
slings carry the total load while the other two slings are simply used to balance the load.
14
11/12
Coil Insert Safe Working Load Reduction Factors For Free Edge Conditions
Tension Loadings Only
D
P
Minimum
D + de
de
de
2"
2-1/4"
2-1/2"
2-3/4"
3"
3-1/2"
4"
4-1/2"
5"
5-1/2"
6"
7"
8"
9"
10"
11"
6"
0.63
0.64
0.65
0.67
0.69
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
1.00
1.00
B1 or B2
8"
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96
B16
12"
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96
4"
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96
1.00
1.00
1.00
1.00
1.00
1.00
6"
0.61
0.63
0.64
0.65
0.67
0.69
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
1.00
1.00
B17
12"
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96
B18
9"
0.57
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91
4-1/2"
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
1.00
1.00
1.00
1.00
F56 to F61
5-1/2" 7-1/2"
0.65
0.61
0.67
0.62
0.68
0.63
0.71
0.66
0.74
0.68
0.77
0.70
0.80
0.72
0.83
0.74
0.86
0.77
0.92
0.81
0.98
0.86
1.00
0.90
1.00
0.94
1.00
0.99
9-1/2"
0.60
0.61
0.62
0.64
0.66
0.68
0.69
0.71
0.75
0.78
0.82
0.85
0.89
2-2/8"
0.79
0.82
0.86
0.90
0.93
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
F63
3-1/2"
0.69
0.71
0.74
0.76
0.79
0.83
0.88
0.93
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
4-1/2"
0.65
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
1.00
1.00
1.00
1.00
Reduced Safe Working Load is based on 1/2" setback from face of concrete.
For Safe Working Load on other insert loading conditions, contact a Dayton Superior Technical Service Department.
Above chart modified from ACI 318 Appendix D method by using previous results from product testing.
Example:
Using a B2 Coil Tie Insert 1" x 8" long in a 2-1/2" free edge condition, multiply concrete safe working load of 9,514lbs. by a
reduction factor of 0.6 to arrive at the reduced concrete safe working load of 5,708lbs. which is less than insert mechanical
capacity of 9,000lbs. so use 5,708lbs.
11/12
15
General and
Technical
Information
General and
Technical
Information
Concrete
Face
de
T =
Wall thickness
de
B1 or B2
6"
8"
B16
B17
B18
B33
F53
F56 to F61
12"
4"
6"
12"
9"
12"
12"
3"
4"
F63
4-1/2"
5-1/2"
7-1/2"
9-1/2"
2-2/8"
3-1/2"
4-1/2"
4"
2"
0.33
0.22
0.15
0.17
0.44
0.33
0.58
0.38
0.30
4-1/2"
2-1/4"
0.25
0.19
0.19
0.38
0.25
0.17
0.19
0.50
0.38
0.33
0.65
0.43
0.33
5"
2-1/2"
0.28
0.21
0.21
0.42
0.28
0.19
0.21
0.56
0.42
0.37
0.30
0.22
0.72
0.48
0.37
5-1/2"
2-3/4"
0.31
0.23
0.23
0.46
0.31
0.20
0.23
0.61
0.46
0.41
0.33
0.24
0.19
0.79
0.52
0.41
6"
3"
0.33
0.25
0.25
0.50
0.33
0.22
0.25
0.67
0.50
0.44
0.36
0.27
0.21
0.86
0.57
0.44
7"
3-1/2"
0.39
0.29
0.29
0.58
0.39
0.26
0.29
0.78
0.58
0.52
0.42
0.31
0.25
1.00
0.67
0.52
8"
4"
0.44
0.33
0.33
0.67
0.44
0.33
0.30
0.33
0.33
0.89
0.67
0.59
0.48
0.36
0.28
1.00
0.76
0.59
9"
4-1/2"
0.50
0.38
0.38
0.75
0.50
0.38
0.33
0.38
0.38
1.00
0.75
0.67
0.55
0.40
0.32
1.00
0.86
0.67
10"
5"
0.56
0.42
0.42
0.83
0.56
0.42
0.37
0.42
0.42
1.00
0.83
0.74
0.61
0.44
0.35
1.00
0.95
0.74
11"
5-1/2"
0.61
0.46
0.46
0.92
0.61
0.46
0.41
0.46
0.46
1.00
0.92
0.81
0.67
0.49
0.39
1.00
1.00
0.81
12"
6"
0.67
0.50
0.50
1.00
0.67
0.50
0.44
0.50
0.50
1.00
1.00
0.89
0.73
0.53
0.42
1.00
1.00
0.89
14"
7"
0.78
0.58
0.58
1.00
0.78
0.58
0.52
0.58
0.58
1.00
1.00
1.00
0.85
0.62
0.49
1.00
1.00
1.00
16"
8"
0.89
0.67
0.67
1.00
0.89
0.67
0.59
0.67
0.67
1.00
1.00
1.00
0.97
0.71
0.56
1.00
1.00
1.00
18"
9"
1.00
0.75
0.75
1.00
1.00
0.75
0.67
0.75
0.75
1.00
1.00
1.00
1.00
0.80
0.63
1.00
1.00
1.00
20"
10"
1.00
0.83
0.83
1.00
1.00
0.83
0.74
0.83
0.83
1.00
1.00
1.00
1.00
0.89
0.70
1.00
1.00
1.00
22"
11"
1.00
0.92
0.92
1.00
1.00
0.92
0.81
0.92
0.92
1.00
1.00
1.00
1.00
0.98
0.77
1.00
1.00
1.00
Reduced Safe Working Load is based on 1/2" setback from face of concrete.
For Safe Working Load on other insert loading conditions, contact a Dayton Superior Technical Service Department.
When an insert is not positioned at the center line of the wall, the effective wall thickness is twice the actual edge distance. Above chart modified from ACI
318 Appendix D method by using previous results from product testing.
Example:
Using a B2 Coil Tie Insert 1" x 12" long in an 8" thin wall, multiply concrete full shear cone capacity of 17,525 by a reduction
factor of 0.33 to arrive at the reduced concrete safe working load of 5,783lbs. which is less than insert mechanical
capacity of 9,000lbs. so use 5,783lbs.
16
11/12
The Swift Lift System is a quick connect-disconnect system that allows precast concrete elements to be handled repeatedly,
with speed, safety and economy. It is a non-welded system and void of threaded connections. The quality, reusable Swift
Lift Lifting Eyes heavy duty construction will provide years of good service.
The Swift Lift System is available with safe load ratings of 1, 2, 4, 8 and 20 tons. Each component is clearly marked with its
maximum safe working load. The System is extremely versatile and can be utilized for vertical and diagonal pulls. It can be
used to lift concrete elements from a horizontal to a vertical position without the aid of a tilting table.
B
A
The Swift Lift Universal Lifting Eye (P50) consists of a flatsided, spherical lifting body and a high strength bail. The
lifting body has a T-shaped slot that permits rapid attachment
and release of the head on Swift Lift Anchors.
Bail
DSC
Load
Range
Tons
Lifting
Body
M
H
F
1.87"
2.95"
2.20"
1.26"
2.80"
7.40"
2.34"
3.58"
2.68"
1.61"
3.41"
9.06"
2.76"
4.65"
3.46"
2.22"
3.46"
11.14"
3.47"
6.30"
4.41"
2.83"
4.52"
15.79"
20
4.18"
7.09"
6.00"
4.29"
5.31"
20.00"
The rated load provides a factor of safety of approximately 5 to 1 (ultimate to rated load).
Limiting Dimensions on
P-50 Swift Lift Universal Lifting Eye
(Tons)
H
Maximum
Width
M
Minimum
Thickness
0.512"
0.217"
0.709"
0.236"
0.984"
0.315"
1.260"
0.472"
20
1.811"
0.709"
Rated
Load
At least once every three months, dimensions H and M on each unit should be checked. The upper limits are shown in
the chart. If either of these limits is exceeded, the P50 Universal Lifting Eye must be removed from service and destroyed.
The proper method for scrapping a lifting eye is to cut through the bail with a cutting torch to render the unit useless as a
lifting device.
No repairs or welding to the P50 Swift Lift Universal Lifting Eye are permitted.
11/12
17
Extended Lip
Note: Prior to lifting a precast element, apply an initial cable tension to make sure that the bail and body of the lifting eye are aligned in the direction
of the cable pull.
180 Usable
Range
Minimum
Edge
Distance
Minimum
Edge
Distance
360
Range
90 or
more
Right
Right
less than
90
Wrong
Dos and Donts of the P50 Swift Lift Universal Lifting Eye
Prior to lifting a precast element,
apply an initial cable tension to make
certain that the bail and body of the
lifting eye are aligned in the direction
of the cable pull.
Warning: The crane line and bail of the lifting hardware must be turned in the direction of the cable forces before the lifting operation begins. The crane line
must not be allowed to apply a sideward force on the bail. This condition is dangerous and could lead to premature failure of the hardware or insert.
Warning: Do not modify, weld or alter in any way the Swift Lift Universal Lifting Eye.
18
11/12
DS_P51
B
A
4
Year of
Manufacture
DSC
D
E
Bail
Load
Range
Tons
Safety Pin
C
F
(Inches)
(Inches)
(Inches)
(Inches)
(Inches)
2.64
4.52
2.36
3.74
8.43
3.00
5.06
2.83
4.96
10.35
3.54
5.98
3.70
5.60
12.87
Limiting Dimensions on
P51 Swift Lift Lifting Eye
Safe
Working
Load (tons)
(Inches)
(Inches)
0.709
0.236
0.984
0.315
1.260
0.472
Check the safety pin; missing pins must be replaced. Make sure the safety pin is in good condition and moves freely
at all times. At least once every three months, dimensions G and F on each unit should be checked. The upper
limits are shown in the chart. If either of these limits is exceeded, the Swift Lift Lifting Eye must be removed from
service and destroyed.
The proper method to use in destroying a lifting eye is to cut through the bail with a cutting torch. Other than replacing
the safety pin, no repairs to the P51 Swift Lift Lifting Eye are permitted. In particular, welding is not permitted.
11/12
19
To engage the P51 Swift Lift Lifting Eye on the head of the Swift Lift Anchor, position the P51 Swift Lift Lifting Eye so that
the front face is toward the concrete, then raise the Swift Lift Lifting Eye into the working position and engage the lifting
hook. The safety pin will drop into position to prevent accidental release of the Swift Lift Lifting Eye.
For inclined pulls, the front face of the P51 Swift Lift Lifting Eye, which indicates the rated load of the lifting eye, must
always be facing away from the concrete surface. This must be checked immediately before the lifting operation begins.
Load rating
embossed on front
face in two locations
Front
face
90 or
less
Warning: If the P51 Swift Lift Lifting Eye is used when its relative position is 90 or 180 from its correct position, the P52
Swift Lift Anchor will be overloaded and may result in a premature failure.
Load Rating
Load Rating
Correct position
(Normal position)
Right
20
Incorrect position
(90 out of position)
Incorrect position
(180 out of position)
Wrong
Wrong
Note: Do not use the lifting eye in this manner as it could bend
and/or break the safety pin, allowing the lifting eye to pull off the
Swift Lift Anchor. Never use lifting eye without a safety pin in
place.
11/12
When the P51 Swift LIft Lifting Eyes position is changed from a diagonal pull to a vertical pull relative to the anchor axis,
all movements are permissible, even with simultaneous rotation.
If the Swift Lift Anchor is positioned in a relatively thin panel, movement of the P51 Swift Lift Lifting Eye under load from
the vertical to an inclined position relative to the axis of the anchor (such as laying down a panel with edge inserts as
shown in 1 below) is NOT PERMITTED due to excessive friction. This friction causes binding of the ball end of the P51 Swift
Lift Lifting Eye, and when the friction is overcome, the resultant sudden movement causes high impact stresses on the
surrounding concrete. As an aid in reducing friction, apply a soap solution to the void formed by the recess plug.
Right
4. Maneuvering from vertical to
horizontal with face anchors
in.
90 M ax.
120 M
90
Wrong
Right
1. Maneuvering from horizontal to vertical with edge anchors
in.
90 MMax.
120
90
90
The above maneuver can be accomplished when the proper rigging is used. The fleet angle between the slings must be
between 90 and 120. In this manner, precast concrete shapes can be placed from the vertical to the horizontal.
in.
90 M x.
a
M
120
Wrong
90
Right
Wrong
2. Maneuvering from vertical to horizontal with edge anchors
Note: To reduce friction between the Swift Lift Lifting Eye and the
concrete, apply a soap solution to the cavity formed by the recess plug.
in.
90 M
.
Max
120
Right
Wrong
3. Maneuvering from horizontal to vertical with face anchors
Note: To reduce friction between the Swift Lift Lifting Eye and the
concrete, apply a soap solution to the cavity formed by the recess plug.
11/12
21
Load Rating
The P52 Swift Lift Anchor is hot forged from carbon steel. The formed
head provides spherical seating that the Lifting Eye engages, while a discshaped foot is embedded in the concrete.
4
Head
Due to its being a forged part, the Swift Lift Anchor does not depend on
welds or thread engagement to develop its safe working load. Forging
provides maximum safety with its advantageous material structure. This
allows the anchor to easily meet the OSHA requirement of a 4 to 1 factor
of safety.
In addition to the carbon steel anchors, Type 304 or 316 Stainless Steel
Swift Lift Anchors are available on special order. Use stainless steel anchors
when maximum protection against corrosion is required.
For safety, refer to the P52 Swift Lift Anchor Selection Chart to determine
the actual safe working load of an individual anchor. The MAXIMUM
safe working load is clearly visible on the head of the anchor for easy
recognition of the appropriate hardware and accessories foruse with each
Swift Lift Anchor.
Shaft
Diameter
Foot
To Order:
Specify: (1) quantity, (2) name, (3) system size,
(4) length
Example:
200, P52 Swift Lift Anchors, 4 ton, 9-1/2" long
Head
Diameter
X
Z
Y
Diameter
of Foot
Swift Lift
Anchor
Diameter of
Recess Plug
Dimension
Z
2-7/16"
1-3/16"
3-5/16"
1-7/16"
4"
1-13/16"
5"
2-5/16"
20 Tons
6-3/8"
3-1/8"
Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.
22
Swift Lift
Anchor
Dimension
X
Dimension
Y
Shaft
Diameter
Foot
Diameter
Head
Diameter
5/16"
7/8"
3/8"
1"
11/16"
7/16"
1-1/16"
9/16"
1-3/8"
1-1/32"
9/16"
1-5/16"
3/4"
1-7/8"
1-11/32"
9/16"
1-5/8"
1-3/32"
2-5/8"
1-7/8"
20 Tons
9/16"
2-5/8"
1-1/2"
3-3/4"
2-3/4"
11/12
Grasp the recess plug firmly across the top diameter of the plug. Application of pressure
by the thumb and fingers on the outer edge of the plug will cause the plug to open up
to allow insertion of the anchor.
Anchor assembly
attached to
template board
11/12
23
ge
Ed
e
m
u nc
im ta
in Dis
M
Min
imu
Distam Edge
nce
PD
PV
PT
When the P52 Swift Lift Anchor is properly embedded in normal weight
concrete, the tabulated working loads are applicable for any direction of
load. This applies even if the direction of load is parallel to the axis of the
anchor, perpendicular to it or at any other angle.
Minimum distance between anchors is twice the minimum edge distance.
It is critical to remember that in order to obtain the safe working loads
listed in the table below, the normal weight concrete must have obtained
the minimum concrete strength shown, prior to initial load application.
Swift Lift Anchor
Ton x Length
Safe Working
Load
Minimum
Concrete Strength
Minimum
Edge Distance
1 ton x 2-5/8"
1,700lbs.
3,500 psi
8"
1 ton x 3-3/8"
2,000lbs.
2,200 psi
10"
1 ton x 4-3/4"
2,000lbs.
1,600 psi
10"
1 ton x 8"
2,000lbs.
1,600 psi
10"
1 ton x 9-1/2"
2,000lbs.
1,600 psi
10"
2 ton x 2-3/4"
2,100lbs.
3,500 psi
8"
2 ton x 3-3/8"
2,900lbs.
3,500 psi
10"
2 ton x 4-3/4"
4,000lbs.
3,500 psi
7.125"
2 ton x 5-1/2"
4,000lbs.
1,600 psi
13"
2 ton x 6"
4,000lbs.
1,600 psi
13"
2 ton x 6-3/4"
4,000lbs.
1,600 psi
13"
2 ton x 11"
4,000lbs.
1,600 psi
14"
4 ton x 3-3/4"
4,000lbs.
3,500 psi
12"
4 ton x 4-1/4"
4,900lbs.
3,500 psi
13"
4 ton x 4-3/4"
5,800lbs.
3,500 psi
14"
4 ton x 5-1/2"
7,400lbs.
3,500 psi
17"
4 ton x 5-3/4"
7,900lbs.
3,500 psi
17"
4 ton x 7-1/8"
8,000lbs.
1,800 psi
20"
4 ton x 9-1/2"
8,000lbs.
1,600 psi
17"
4 ton x 14"
8,000lbs.
1,600 psi
18"
4 ton x 19"
8,000lbs.
1,600 psi
20"
8 ton x 4-3/4"
6,400lbs.
3,500 psi
7.875"
8 ton x 5-1/4"
6,850lbs.
3,500 psi
16"
8 ton x 6-3/4"
11,200lbs.
3,500 psi
21"
8 ton x 10"
16,000lbs.
3,500 psi
19"
8 ton x 13-3/8"
16,000lbs.
1,600 psi
23"
8 ton x 26-3/4"
16,000lbs.
1,600 psi
27"
20 ton x 10"
25,000lbs.
3,500 psi
24"
20 ton x 19-3/4"
40,000lbs.
3,500 psi
31"
Safe Working Loads provide a factor of safety of approximately 4 to1 in normal weight concrete. Safe Working Load is
based on anchor setback from face of concrete X dimension, as shown on page 26.
24
11/12
The P52W Swift Lift Anchors are the shortest 2-ton and 4-ton Swift Lift Anchors available and have been
specially modified. A Type W Plain Washer is placed on the anchors foot and welded in position. This
modification has been made in order to increase the Safe Working Load of these short Swift Lift Anchors in
thin precast concrete elements.
W
To Order:
Specify: (1) quantity, (2) name, (3) system size.
Example:
200, P52W Swift Lift Anchors, 2 ton.
Swift Lift Anchor
Tons x Length
Safe
Working Load
Minimum Concrete
Strength
Minimum Edge
Distance
2 tons x 2-3/4"
3,700 lbs.
4 tons x 3-3/4"
5,700 lbs.
3,500 psi
8"
2-1/2"
3,500 psi
12"
2-3/4"
Casting Surface
P59 Shear Bar
C/2
equ
m
a
corn inimumls
er d
istan
ce
The applied shear load tends to bend the anchor, allowing the lifting
eye to apply load to the thin concrete section above the recess plug. A
properly installed shear bar captures the applied load and transfers it
deeper into the concrete.
When raising precast panels from a horizontal position to a vertical position,
always check both shear and tension safe working loads. In order to develop
the anchors shear safe working load, the minimum spacing between Swift
Lift Anchors is two times the corner distance listed.
Note: Properly installed shear bars are required to develop Safe Working
Loads shown. 2 x de equals effective wall thickness for tensile loads.
dse
de
Support anchor
with bar chair
P
dse (top)
Position P59
shear bar
tight against
recess plug
de (bottom)
Casting surface
11/12
25
To Order:
Specify: (1) quantity, (2) name, (3) system size.
Example:
Overall Width
Wall
Thickness
Minimum
Corner
Distance
Safe
Working
Load
4-3/4"
5"
15"
1,750 lbs.
4-3/4"
5-1/2"
16"
2,000 lbs.
19"
4-3/4"
6"
17"
2,000 lbs.
24"
6-3/4"
5"
15"
1,750 lbs.
24"
6-3/4"
5-1/2"
16"
2,200 lbs.
24"
6-3/4"
6"
17"
2,600 lbs.
Wire
24"
6-3/4"
7"
19"
2,700 lbs.
Wire
24"
6-3/4"
8"
21"
2,800 lbs.
Wire
30"
9-1/2"
5-1/2"
16"
2,100 lbs.
Wire
30"
9-1/2"
6"
17"
2,200 lbs.
Wire
30"
9-1/2"
7"
19"
2,600 lbs.
Wire
30"
9-1/2"
8"
21"
2,800 lbs.
Rebar
34"
13-3/8"
8"
19"
5,600 lbs.
Rebar
34"
13-3/8"
9"
21"
6,700 lbs.
Shear Bar
Type
Overall
Width
Minimum
Anchor
Length
Rebar
19"
Rebar
19"
Rebar
Wire
Wire
Wire
Anchor Safe
Working Load
(tons)
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
26
11/12
The P52 Swift Lift Anchors, listed below, must be located the minimum distance away from a corner with the anchor foot
being positioned at the center line of the wall. The anchor head location may be off center, however, any eccentricity of
the foot will result in a reduction of the safe working load. When the anchor foot is not positioned at the center line of the
wall, the effective wall thickness is equal to twice the actual edge distance.
To develop the safe working load of the P52 Swift Lift Anchor, the minimum spacing between two anchors is six times the
anchor length.
P
Corner Distance
L = P52
Anchor
Length
Wall
center
line
de
Effective
Wall
Thickness
Center Line
of Anchor Foot
and Wall
de
de
Actual Wall
Thickness
Effective
Wall Thickness
1 Ton
x
4-3/4"
Long
1 Ton
x
9-1/2"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
6"
12"
18"
24"
30"
2-1/2"
1-1/4"
900 lbs.
1,100 lbs.
1,200 lbs.
1,200 lbs.
1,200 lbs.
2-3/4"
1-3/8"
1,000 lbs.
1,200 lbs.
1,300 lbs.
1,300 lbs.
1,300 lbs.
3"
1-1/2"
1,100 lbs.
1,300 lbs.
1,400 lbs.
1,400 lbs.
1,400 lbs.
3-1/2"
1-3/4"
1,200 lbs.
1,600 lbs.
1,600 lbs.
1,600 lbs.
1,600 lbs.
4"
2"
1,450 lbs.
1,800 lbs.
1,900 lbs.
1,900 lbs.
1,900 lbs.
4-1/2"
2-1/4"
1,600 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2-1/2"
1-1/4"
1,300 lbs.
1,700 lbs.
1,900 lbs.
1,900 lbs.
1,900 lbs.
2-3/4"
1-3/8"
1,400 lbs.
1,900 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
3"
1-1/2"
1,500 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
3-1/2"
1-3/4"
1,800 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
4"
2"
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
4-1/2"
2-1/4"
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
11/12
27
Swift Lift
Anchor
Tons x
Length
2 Tons
x
6-3/4"
Long
2 Tons
x
11"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
8"
12"
18"
24"
30"
3"
1-1/2"
1,500 lbs.
1,700 lbs.
2,000 lbs.
2,000 lbs.
2,000 lbs.
3-1/4"
1-5/8"
1,600 lbs.
1,900 lbs.
2,100 lbs.
2,200 lbs.
2,200 lbs.
3-1/2"
1-3/4"
1,700 lbs.
2,000 lbs.
2,300 lbs.
2,300 lbs.
2,300 lbs.
4"
2"
2,000 lbs.
2,300 lbs.
2,600 lbs.
2,700 lbs.
2,700 lbs.
5"
2-1/2"
2,500 lbs.
2,900 lbs.
3,300 lbs.
3,400 lbs.
3,400 lbs.
6"
3"
3,000 lbs.
3,500 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
3"
1-1/2"
1,900 lbs.
2,300 lbs.
2,700 lbs.
3,000 lbs.
3,200 lbs.
3-1/4"
1-5/8"
2,100 lbs.
2,500 lbs.
3,000 lbs.
3,300 lbs.
3,500 lbs.
3-1/2"
1-3/4"
2,200 lbs.
2,700 lbs.
3,200 lbs.
3,500 lbs.
3,700 lbs.
4"
2"
2,500 lbs.
3,100 lbs.
3,700 lbs.
4,000 lbs.
4,000 lbs.
5"
2-1/2"
3,200 lbs.
3,900 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
6"
3"
3,800 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
Swift Lift
Anchor
Tons x
Length
4 Tons
x
9-1/2"
Long
4 Tons
x
19"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
10"
15"
20"
24"
30"
3-3/4"
1-7/8"
2,500 lbs.
3,000 lbs.
3,300 lbs.
3,400 lbs.
3,500 lbs.
4"
2"
2,600 lbs.
3,200 lbs.
3,500 lbs.
3,700 lbs.
3,800 lbs.
5"
2-1/2"
3,300 lbs.
4,000 lbs.
4,400 lbs.
4,600 lbs.
4,700 lbs.
6"
3"
4,000 lbs.
4,800 lbs.
5,300 lbs.
5,500 lbs.
5,700 lbs.
7"
3-1/2"
4,700 lbs.
5,600 lbs.
6,200 lbs.
6,500 lbs.
6,600 lbs.
8"
4"
5,300 lbs.
6,400 lbs.
7,000 lbs.
7,400 lbs.
7,600 lbs.
3-3/4"
1-7/8"
3,500 lbs.
4,300 lbs.
4,900 lbs.
5,300 lbs.
5,800 lbs.
4"
2"
3,800 lbs.
4,600 lbs.
5,300 lbs.
5,700 lbs.
6,200 lbs.
5"
2-1/2"
4,700 lbs.
5,700 lbs.
6,600 lbs.
7,100 lbs.
7,800 lbs.
6"
3"
5,700 lbs.
6,900 lbs.
7,900 lbs.
8,000 lbs.
8,000 lbs.
7"
3-1/2"
6,600 lbs.
8,000 lbs.
8,000 lbs.
8,000 lbs.
8,000 lbs.
8"
4"
7,600 lbs.
8,000 lbs.
8,000 lbs.
8,000 lbs.
8,000 lbs.
Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
28
11/12
Swift Lift
Anchor
Tons x
Length
8 Tons
x
13-3/8"
Long
8 Tons
x
26-3/4"
Long
Effective
Wall
Thickness
2de
Actual
Edge
Distance
de
12"
18"
24"
36"
45"
4-3/4"
2-3/8"
4,000 lbs.
4,800 lbs.
5,400 lbs.
6,000 lbs.
6,100 lbs.
5"
2-1/2"
4,200 lbs.
5,100 lbs.
5,700 lbs.
6,300 lbs.
6,400 lbs.
6"
3"
5,100 lbs.
6,100 lbs.
6,800 lbs.
7,500 lbs.
7,600 lbs.
7"
3-1/2"
5,900 lbs.
7,100 lbs.
8,000 lbs.
8,800 lbs.
8,900 lbs.
8"
4"
6,800 lbs.
8,100 lbs.
9,100 lbs.
10,100 lbs.
10,200 lbs.
10"
5"
8,500 lbs.
10,200 lbs.
11,400 lbs.
12,600 lbs.
12,700 lbs.
12"
6"
10,200 lbs.
12,200 lbs.
13,700 lbs.
15,100 lbs.
15,200 lbs.
4-3/4"
2-3/8"
5,800 lbs.
7,000 lbs.
8,000 lbs.
9,600 lbs.
11,200 lbs.
5"
2-1/2"
6,100 lbs.
7,400 lbs.
8,500 lbs.
10,100 lbs.
11,800 lbs.
6"
3"
7,300 lbs.
8,900 lbs.
9,500 lbs.
12,100 lbs.
14,100 lbs.
7"
3-1/2"
8,500 lbs.
10,300 lbs.
11,800 lbs.
14,200 lbs.
16,000 lbs.
8"
4"
9,700 lbs.
11,800 lbs.
13,500 lbs.
16,000 lbs.
16,000 lbs.
10"
5"
12,100 lbs.
14,800 lbs.
16,000 lbs.
16,000 lbs.
16,000 lbs.
12"
6"
14,500 lbs.
16,000 lbs.
16,000 lbs.
16,000 lbs.
16,000 lbs.
Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
Swift Lift
Anchor
Tons x
Length
20 Tons
x
19-3/4"
Long
Effective
Wall
Thickness
2de
Actual
Edge
Distance
de
10"
16"
24"
6-1/2"
3-1/4"
6,200 lbs.
7,500 lbs.
9,400 lbs.
10,300 lbs.
11,500 lbs.
7"
3-1/2"
6,700 lbs.
8,100 lbs.
10,100 lbs.
11,100 lbs.
12,400 lbs.
8"
4"
7,600 lbs.
8,900 lbs.
11,500 lbs.
12,600 lbs.
14,200 lbs.
10"
5"
9,500 lbs.
11,600 lbs.
14,400 lbs.
15,800 lbs.
17,700 lbs.
12"
6"
11,500 lbs.
14,000 lbs.
17,300 lbs.
19,000 lbs.
22,000 lbs.
14"
7"
13,400 lbs.
16,300 lbs.
20,100 lbs.
22,100 lbs.
24,800 lbs.
42"
Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
To recalculate the safe working load when the anchor is used in a lower strength concrete, multiply the tabulated Safe
Working Load by the following reduction factors:
Concrete Strength
Reduction Factor
2,000 psi
.66
2,500 psi
.74
3,000 psi
.81
3,500 psi
.88
4,000 psi
.94
4,500 psi
1.00
11/12
29
2 Tons
x
6-3/4"
Long
2 Tons
x
11"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
18"
24"
30"
36"
48"
3"
1-1/2"
1,200 lbs.
1,500 lbs.
1,800 lbs.
1,900 lbs.
2,000 lbs.
3-1/4"
1-5/8"
1,300 lbs.
1,700 lbs.
1,900 lbs.
2,100 lbs.
2,200 lbs.
3-1/2"
1-3/4"
1,400 lbs.
1,800 lbs.
2,100 lbs.
2,300 lbs.
2,400 lbs.
4"
2"
1,600 lbs.
2,100 lbs.
2,400 lbs.
2,600 lbs.
2,700 lbs.
5"
2-1/2"
2,000 lbs.
2,600 lbs.
3,000 lbs.
3,200 lbs.
3,400 lbs.
6"
3"
2,500 lbs.
3,100 lbs.
3,600 lbs.
3,900 lbs.
4,000 lbs.
3"
1-1/2"
1,300 lbs.
1,700 lbs.
2,000 lbs.
2,300 lbs.
2,900 lbs.
3-1/4"
1-5/8"
1,400 lbs.
1,800 lbs.
2,200 lbs.
2,500 lbs.
3,100 lbs.
3-1/2"
1-3/4"
1,500 lbs.
1,900 lbs.
2,400 lbs.
2,700 lbs.
3,300 lbs.
4"
2"
1,700 lbs.
2,200 lbs.
2,700 lbs.
3,100 lbs.
3,800 lbs.
5"
2-1/2"
2,100 lbs.
2,800 lbs.
3,400 lbs.
3,900 lbs.
4,000 lbs.
6"
3"
2,600 lbs.
3,400 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
Swift Lift
Anchor
Tons x
Length
4 Tons
x
9-1/2"
Long
4 Tons
x
19"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
18"
24"
36"
48"
60"
3-3/4"
1-7/8"
1,600 lbs.
2,000 lbs.
2,800 lbs.
3,300 lbs.
3,500 lbs.
4"
2"
1,700 lbs.
2,200 lbs.
3,000 lbs.
3,600 lbs.
3,800 lbs.
5"
2-1/2"
2,100 lbs.
2,700 lbs.
3,800 lbs.
4,500 lbs.
4,700 lbs.
6"
3"
2,500 lbs.
3,300 lbs.
4,600 lbs.
5,400 lbs.
5,700 lbs.
7"
3-1/2"
3,000 lbs.
3,900 lbs.
5,300 lbs.
6,300 lbs.
6,700 lbs.
8"
4"
3,400 lbs.
4,400 lbs.
6,100 lbs.
7,200 lbs.
7,600 lbs.
3-3/4"
1-7/8"
1,600 lbs.
2,200 lbs.
3,200 lbs.
4,100 lbs.
5,000 lbs.
4"
2"
1,700 lbs.
2,300 lbs.
3,400 lbs.
4,400 lbs.
5,300 lbs.
5"
2-1/2"
2,200 lbs.
2,900 lbs.
4,300 lbs.
5,500 lbs.
6,600 lbs.
6"
3"
2,600 lbs.
3,500 lbs.
5,100 lbs.
6,600 lbs.
8,000 lbs.
7"
3-1/2"
3,100 lbs.
4,100 lbs.
6,000 lbs.
7,700 lbs.
8,000 lbs.
8"
4"
3,500 lbs.
4,500 lbs.
6,800 lbs.
8,000 lbs.
8,000 lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
30
11/12
Swift Lift
Anchor
Tons x
Length
8 Tons
x
13-3/8"
Long
8 Tons
x
26-3/4"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
18"
24"
36"
48"
60"
4-3/4"
2-3/8"
2,800 lbs.
3,600 lbs.
4,800 lbs.
5,300 lbs.
5,300 lbs.
5"
2-1/2"
2,900 lbs.
3,800 lbs.
5,000 lbs.
5,600 lbs.
5,600 lbs.
6"
3"
3,500 lbs.
4,500 lbs.
6,000 lbs.
6,700 lbs.
6,700 lbs.
7"
3-1/2"
4,100 lbs.
5,300 lbs.
7,100 lbs.
7,800 lbs.
7,800 lbs.
8"
4"
4,700 lbs.
6,000 lbs.
8,100 lbs.
8,900 lbs.
8,900 lbs.
10"
5"
5,900 lbs.
7,500 lbs.
10,100 lbs.
11,200 lbs.
11,200 lbs.
12"
5-1/2"
6,500 lbs.
8,300 lbs.
11,000 lbs.
12,300 lbs.
12,300 lbs.
4-3/4"
2-3/8"
2,900 lbs.
3,800 lbs.
5,600 lbs.
7,200 lbs.
8,500 lbs.
5"
2-1/2"
3,100 lbs.
4,000 lbs.
5,900 lbs.
7,600 lbs.
9,000 lbs.
6"
3"
3,700 lbs.
4,800 lbs.
7,100 lbs.
9,100 lbs.
10,800 lbs.
7"
3-1/2"
4,300 lbs.
5,700 lbs.
8,300 lbs.
10,600 lbs.
12,500 lbs.
8"
4"
4,900 lbs.
6,500 lbs.
9,400 lbs.
12,100 lbs.
14,300 lbs.
10"
5"
6,100 lbs.
8,100 lbs.
11,800 lbs.
15,100 lbs.
16,000 lbs.
12"
5-1/2"
6,700 lbs.
8,900 lbs.
13,000 lbs.
16,000 lbs.
16,000 lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
Swift Lift
Anchor
Tons x
Length
20 Tons
x
19-3/4"
Long
Effective
Wall
Thickness
2 de
Actual
Edge
Distance
de
20"
24"
33"
42"
60"
6-1/2"
3-1/4"
4,300 lbs.
5,200 lbs.
6,800 lbs.
8,300 lbs.
10,200 lbs.
7"
3-1/2"
4,700 lbs.
5,600 lbs.
7,400 lbs.
8,900 lbs.
11,000 lbs.
8"
4"
5,400 lbs.
6,300 lbs.
8,400 lbs.
10,200 lbs.
12,600 lbs.
10"
5"
6,700 lbs.
7,900 lbs.
10,500 lbs.
12,700 lbs.
15,700 lbs.
12"
6"
8,000 lbs.
9,500 lbs.
12,600 lbs.
15,300 lbs.
18,900 lbs.
7"
9,300 lbs.
11,100 lbs.
14,700 lbs.
17,800 lbs.
22,000 lbs.
14"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.
To recalculate the Safe Working Loads when the anchor is used in a lower strength concrete, multiply the tabulated Safe
Working Load by the following reduction factors:
Concrete Strength
Reduction Factor
2,000 psi
.66
2,500 psi
.74
3,000 psi
.81
3,500 psi
.88
4,000 psi
.94
4,500 psi
1.00
11/12
31
The Dayton Superior Swift LIft Eye Anchor (P53) is similar to the P52 anchor but has an eye at the foot to accept P60
Tension Bars. The P53 anchor is used primarily in thin sections, thin panels of lightweight concrete or shapes that must be
handled at concrete compressive strengths below 2,000 psi. P53 anchors are available in 1, 2, 4, 8 and 20-ton capacities
and each has its load rating embossed on the head.
4
To Order:
Specify: (1) quantity, (2) name, (3) system size, (4) length.
Example:
200, P53 Swift Lift Eye Anchors, 4 ton, 9-1/2" long.
i
lW
e
Pan
m
m
u
u
nim inim er
Mi
M orn ce
C tan
Dis
Center line
of wall
and P53
Swift Lift
Eye
Anchor
m
imu idth
Min n W
m
lu
Co
CL
M
Col inim
um um
nD
ept
h
CL
L
L = Anchor
Length
Anchor Length
L
Minimum
Thickness or
Depth
de
Actual Edge
Distance
de
Minimum
Corner
Distance
Minimum
Panel Width
Tensile Safe
Working Load
per Anchor*
(lbs.)
2-1/2"
3"
1-1/2"
8"
16"
2,000
3-1/2"
3"
1-1/2"
4"
8"
4,000
4-3/4"
3-3/4"
1-7/8"
5"
10"
8,000
7-1/16"
4-3/4"
2-3/8"
7"
14"
16,000
20
9-7/8"
6-3/8"
3-3/16"
8-1/2"
17"
40,000
* Safe Working Load provides a factor of safety of approximately 4 to 1 in 2,000 psi normal weight concrete. The P53 Eye Anchor must be used in conjunction
with the P60 Tension Bar in order to develop its published rated working loads.
Note: Contact Dayton Superior Technical Service Department for safe working loads when the P53 Eye Anchor is used with straight lengths of rebar.
32
11/12
The Dayton Superior Swift Lift Tension Bar (P60) is designed to be used with the P53 Eye Anchor in order for the eye anchor
to develop its published rated working loads. See P60 sizes and dimensions below.
To Order:
Specify: (1) quantity, (2) name, (3) anchor size.
Example:
200, P60 Swift Lift Tension Bar, 10-ton anchor.
Grade 60
Rebar
Size
Rebar
Overall
Length
Standard
.306" Wire
40"
14"
#3
24"
5"
#5
24"
#6
48"
20
#9
156"
(Tons)
A
Maximum
3/4"
7 -1 /2 "
1-1/8"
6 -1 /4 "
10"
1-7/8"
9 -1 /2 "
15"
2-1/4"
1 2 -1 /2 "
20"
3"
Note: Wire style is for use with 1 ton P53 Eye Anchors only.
14"
Right
11/12
Wrong
33
Example:
200, P54 Swift Lift Recess Plugs, 4-ton anchor.
Anchor Foot
Anchor
Head
Anchor
Foot
P52 Swift
Lift Anchor
34
11/12
The Dayton Superior P56 Swift Lift Narrow Recess Plug is designed for use in thin-wall conditions, such as the top edge
of highway safety barriers. The recess plug is bolted to the form using a P63 stud and P64 wing nut combination and it
correctly positions the anchor below the surface of the concrete. P56 recess plugs are fabricated from nitrile butadiene and
are ideal for conditions requiring temperature or oil resistance.
T
To Order:
Specify: (1) quantity, (2) name, (3) anchor size.
Example:
Z
Diameter
Swift Lift
Anchor
Diameter
of
Recess Plug
Dimension
Z
Dimension
T
Dimension
B
2-3/8"
1-3/16"
1-21/32"
1-11/32"
3"
1-7/16"
2-1/32"
1-23/32"
3-3/4"
1-13/16"
2-3/4"
2-9/32"
4-3/4"
2-5/16"
3-11/32"
2-15/16"
20 Tons
6-3/8"
3-1/8"
4-15/16"
4-7/16"
Note: The diameter of the narrow recess plug is the same as the diameter of
the round recess plug.
Diameter
11/12
Swift Lift
Anchor
Diameter
of
Recess Plug
Depth
"Z"
2.375
1.188
2.918
1.514
3.661
1.875
4.659
2.375
20 Tons
6.375
3.063
35
DS_P56PL
The Dayton Superior P56PL Swift Lift Plus Recess Plug is manufactured from highgrade elastomeric, thermal set urethane to provide improved tear, heat and chemical
resistance. The versatile, reusable plug utilizes a variety of accessories to provide
installation and stripping ease in many different applications. P56PL recess plugs are
available for 1, 2, 4 and 8-ton system sizes. See dimensions of P56PL Recess Plug in
P52 information.
Fixed
Nut
Free
Running
Nut
To Order:
Holding
Stud
With
Wing Nut
P63PL
Example:
200, P54PL Swift Lift Plus Recess Plugs, 4-ton anchor.
Coil Wing
Nut P64PL
Holding Plate
P68PL
Holding Plate
(Optional)
P68PL
Stud Plate
P67PL
Tapped
Plate P66PL
Recess Plug
P56PL
Recess Plug
P56PL
Recess Plug
P56PL
Swift Lift
Anchor REF
Swift Lift
Anchor REF
Swift Lift
Anchor REF
DS_P57
The Dayton Superior P57 Swift Lift Steel Recess Plug is designed for
permanent or semi-permanent attachment to repetitive-use precast
forms, such as battery molds, steel forms that have a collapsible
stripping feature, etc. The recess plug is drilled and tapped for easy
attachment to the form or may be held in place by a magnetic plate,
tack welded or glued. Available in 1, 2 and 4 ton only.
The P58 Swift Lift Rubber Ring is placed on the shaft of the anchor and
seats in the recess plug to hold the anchor firmly in the recess plug. It is
recommended that when the P57 recess plug is used, the anchor end be
supported to prevent dislodging (See sketch below).
P57 Swift
Lift Steel
Recess Plug
To Order:
Specify: (1) quantity, (2) name, (3) anchor size.
Example:
Form
Face
36
11/12
The Dayton Superior P61 Swift Lift Setting Plate and P62
Countersunk Screw combination provide an easy method of
placing a Swift Lift Anchor into the surface of a flat panel without
obstructing the screeding process. The P61 setting plate is available
in two sizes, a 4" unit for use with 4-ton anchors and a 5" unit for
use with 8-ton anchors. The P62 screw is available in two sizes to
match the setting plates. The 4-ton setup uses a 3/4" long, 5/16"
18 NC thread screw and the 8-ton setup uses a 3/4" long, 7/16" 14
NC thread screw.DS_P61_P62
Anchor
Setting
Plate With
Countersunk
Screw
Tapped
Plate
Rubber
Recess
Plug
To Order:
Specify: (1) quantity, (2) name, (3) anchor size.
Example:
P62 Swift Lift
Countersunk Screw
DS_P63_P64
The Dayton Superior P63 Swift Lift Stud and P64 Wing Nut combination is used to set P56 Narrow Recess Plugs. Available in two
sizes, 5/16" 18 NC threads for use with the 1-ton anchor and 7/16" 14 NC threads for use with 2, 4, 8 and 20-ton P56 anchors.
To Order:
Specify: (1) quantity, (2) name, (3) size.
Example:
P64 Swift Lift
Wing Nut
P63PL Swift Lift Plus Holding Stud, P64PL Swift Lift Plus Wing Nut
The Dayton Superior P63PL Swift Lift Plus Holding Stud is a 3/8" diameter, coil threaded stud with a fixed wing nut and a
free-running wing nut used with the P66PL threaded plate to quickly attach the P56PL recess plug to the formwork. The
holding stud is inserted through the form and threaded into the threaded plate. Complete the anchor installation by
screwing the free-running wing nut tightly against the form. DS_P63PL_P64PL
The P64PL Wing Nut has 3/8" diameter coil thread and is available as a replacement nut for the P63PL Holding Stud.
Fixed
Thread
Free
Reduced
Diameter
Threaded Nose
6"
Holding
Stud
To Order:
Specify: (1) quantity, (2) name.
Example:
200, P63PL Swift Lift Plus Holding Studs.
11/12
37
The Dayton Superior Swift Lift Tapped Plate (P66) is tapped for either a 5/16" or 7/16" diameter NC thread and used to install the
P56 Narrow Recess Plug. This is a replacement plate only; it can be used with the P63 Stud or with NC bolts supplied by others.
To Order:
Example:
100, P66 Swift Lift Tapped Plate, 7/16" dia. NC
thread.
To Order:
P66PL Swift Lift
Plus Threaded
Plate
Length
Example:
P68PL Swift Lift Plus
Holding Plate
To Order:
Specify: (1) quantity, (2) name, (3) system size.
NOTE: One piece recess plug with magnets
imbedded in top available, contact DSC
Customer Service.
Example:
20, P69 Swift Lift Magnetic Setting Plates, 4-ton
system.
DS_P104
The Dayton Superior P104 Magnetic OnePiece Swift Lift Recess is a urethane recess plug with magnets embedded in the
face for easy attachment to metal forms. This provides the precaster the option for a one-piece unit versus P56PL Swift Lift
Recess Plug and P69 Magnetic Setting Plate. It is available in 2, 4 and 8-ton sizes.
Diameter
To Order:
Specify: (1) quantity, (2) name, (3) system size.
Example:
Z
38
11/12
Fleet-Lift System
Fleet-Lift System Overview
Fleet-Lift System
The Dayton Superior Fleet-Lift System comprises two main parts, the Fleet-Lift Anchor and the Fleet-Lift Ring Clutch. The
design of the system allows loads to be applied from any direction.
Rigging configuration
Edge distance
Anchor spacing
Each Fleet-Lift anchor is stamped with its MAXIMUM safe working load and the letters DSC, which identifies it as a
Dayton Superior Corporation product. The hole near the top of the anchor head is designed to receive the appropriate
size ring clutch.
Both the anchor and ring clutch are rated with a safe working load. The safe working load of the anchor is based on a
factor of safety of 4 to 1 (ultimate to safe). Each ring clutch has a Load Range embossed on it, which shows the anchors it
can be used with. A factor of safety of 5 to 1 is applied to the highest load in the range for each size of ring clutch.
To use, simply push the ring clutch onto the head of the anchor that is located in a recess created by a Fleet-Lift recess plug.
Once the ring clutch is pushed onto the head of the anchor, the ring clutchs curved bolt is pushed through the hole in the
anchor. This locks the ring clutch and anchor into a single unit ready to lift the precast concrete element.
To disengage the anchor and ring clutch, simply pull the curved bolt free of the anchor this allows the ring clutch to be
easily removed form the head of the anchor.
Dayton Superior recommends a minimum 3/4" cover between the bottom of an anchor and the concrete surface. This
minimum recommended concrete cover is to prevent anchor corrosion.
11/12
39
Fleet-Lift System
P91S Fleet-Lift Ring Clutch DS_P91S
The P91S Fleet-Lift Ring Clutch consists of a clutch body, a curved bolt and a high strength bail.
Installation and release is safe and simple. After the clutch is inserted over the anchor head
and into the recess, the curved bolt is rotated into the closed position.
A
B
Rotation of the standard bail is a full 360 . Once engaged and supporting four hundred
pounds of load, the ring clutch cannot be released.
E
G
To Order:
Fleet-Lift System
Example:
9, P91S Fleet-Lift Ring Clutches, FL002S, 4/6-ton units.
P91S Fleet-Lift Ring Clutch Selection Chart
Safe Working
Load
(Tons)
Load
Range
(Tons)
Product
Code
2-3
FL001S
3-3/4"
2-3/8"
10-1/2"
3"
7"
3"
1"
4-6
FL002S
4-3/4"
2-5/8"
12-1/2"
4"
8-1/4"
3-1/2"
1-1/2"
10
8-10
FL003S
5-7/8"
3"
17-3/4"
5-7/8"
11"
4-1/2"
2-1/8"
22
12.5-22
FL004S
4-3/4"
3-5/8"
21-1/4"
8-1/4"
14-7/8"
4-3/4"
2-7/8"
40
11/12
Fleet-Lift System
P91NC Fleet-Lift Cable Bail Ring Clutch DS_P91NC
The Fleet-Lift Ring Clutch with cable bail can be the solution to many difficult lifting and rotating-tovertical situations. Cable bails can also be used to replace bent or damaged bails on standard clutches.
D
E
The engagement, use and release of the Cable Bail Ring Clutch are similar in operation to the
standard Ring Clutch with the fixed bail.
Once the load is relaxed, the ring clutch can be easily released.
P91NC Fleet-Lift Cable Bail Ring Clutch Selection Chart
Load Range
(Tons)
Product
Code
2-3
FL001NC
30"
9/16"
2-3/4"
2-3/8"
4-3/8"
4-6
FL002NC
36"
3/4"
3-11/16"
3-38"
6-5/8"
10
8-10
FL003NC
36"
1"
5-5/16"
3-3/4"
7-1/8"
Fleet-Lift System
Safe Working
Load
(Tons)
To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) system size.
Example:
P91NC Fleet-Lift
Cable Bail Ring Clutch
Load
Range
2-3
0.562"
4-6
0.781"
10
8-10
0.921"
(Tons)
(Tons)
11/12
41
Fleet-Lift System
P92 Fleet-Lift Erection Anchor DS_P92
Fleet-Lift P92 Erection Anchors are specifically designed for horizontal to vertical
edge lifts and handling of thin-walled precast concrete elements. Two steel
protrusions or ears on the head of the anchor provide protection against
concrete spalling. These protrusions restrict the ring clutch rotation during
lateral pulls. As a result, lateral forces are transmitted directly to the edge of the
anchor instead of the concrete.
E D
Fleet-Lift System
The body of the Erection Anchor is shaped to allow full reinforcement for secure
support and spall-free rotation.
P92 Erection Anchors are available plain or hot-dipped galvanized.
To Order:
Example:
200, P92 Fleet-Lift Erection Anchors, FL047, hotdipped galvanized.
H
J
Product Code
FL047
FL048
FL049*
3-3/4"
(Tons)
2-3/8"
3-3/8"
3-3/16"
4-7/16"
5-3/4"
2"
8"
3/8"
1-13/16"
2-1/2"
10-7/16"
5/8"
2-1/2"
13-1/4"
3/4"
3-1/8"
4"
5/8"
1"
1/2"
3/8"
3/4"
1-1/4"
3/4"
7/16"
1"
1-3/4"
3/4"
5/8"
Shear Reinforcement
Direction of Lift
Stress is caused during the edge lift of a panel, making supplemental reinforcement
around the anchor necessary in thin panels. Fleet-Lift P98S Shear Bars are designed
expressly for this purpose. Place the shear bar in the side notch of the anchor as
shown in the sketch at right.
Reference P98S Shear Bar section for more information.
Note: A properly installed P98S Shear Bar is required to develop the shear safe working loads
shown in the chart on the following page.
Tension Reinforcement
The P92 Dayton Superior Fleet-Lift Erection Anchor is manufactured with a steel
tension pin that resists pullout during normal erection situations. The safe working
load chart, on the following page, list two sets of tension values. If the higher safe
working load is used, the anchor must be properly reinforced using the P98T Tension
Reinforcement. The tension bar should be placed through the lower hole of the
anchor.
Reference P98T Tension Reinforcement section for more information.
Typical P92 Fleet-Lift Erection
Anchor/Tension Bar Application
42
11/12
Fleet-Lift System
P92 Fleet-Lift Erection Anchor Tension and Shear Capacities
P92 Fleet-Lift
Erection Anchor
Product
Code
Precast Concrete
Panel Thickness
FL047
4" Min.
1,650 lbs.
2,575 lbs.
4,000 lbs.
FL047
5"
1,875 lbs.
3,350 lbs.
4,000 lbs.
FL047
6"
2,125 lbs.
3,850 lbs.
4,000 lbs.
FL047
7"
2,400 lbs.
4,000 lbs.
4,000 lbs.
FL047
8"
2,700 lbs.
4,000 lbs.
4,000 lbs.
FL047
9"
2,925 lbs.
4,000 lbs.
4,000 lbs.
FL047
10"
3,275 lbs.
4,000 lbs.
4,000 lbs.
FL047
11"
3,575 lbs.
4,000 lbs.
4,000 lbs.
FL047
12"
4,000 lbs.
4,000 lbs.
4,000 lbs.
FL048
5-1/2" Min.
2,400 lbs.
4,700 lbs.
8,000 lbs.
FL048
6"
3,075 lbs.
5,050 lbs.
8,000 lbs.
FL048
7"
3,250 lbs.
5,825 lbs.
8,000 lbs.
FL048
8"
3,425 lbs.
6,600 lbs.
8,000 lbs.
FL048
9"
3,825 lbs.
7,350 lbs.
8,000 lbs.
FL048
10"
4,250 lbs.
8,000 lbs.
8,000 lbs.
FL048
11"
4,650 lbs.
8,000 lbs.
8,000 lbs.
FL048
12"
5,050 lbs.
8,000 lbs.
8,000 lbs.
FL049
7-1/2" Min.
4,000 lbs.
7,500 lbs.
16,000 lbs.
FL049
8"
4,200 lbs.
7,775 lbs.
16,000 lbs.
FL049
9"
4,550 lbs.
8,300 lbs.
16,000 lbs.
FL049
10"
4,950 lbs.
8,800 lbs.
16,000 lbs.
FL049
11"
5,050 lbs.
10,000 lbs.
16,000 lbs.
FL049
12"
5,175 lbs.
11,300 lbs.
16,000 lbs.
Fleet-Lift System
(ton x length)
Notes:
1. Safe Working Loads are based on approximately a 4 to 1 factor of safety in 3,500 psi normal weight concrete.
2. Install shear bar and tension bar, when required, per instructions on preceding page.
11/12
43
Fleet-Lift System
P92P Fleet-Lift Erection Anchor with Shear Plate
DS_P92P
The P92P Fleet-Lift Erection Anchor with Shear Plate is designed specifically for edge
tilting precast concrete elements from the horizontal to a vertical position. An integral
shear plate eliminates any possibility of forgetting to install a required shear bar.
As on other Fleet-Lift Erection Anchors, two steel protrusions or ears at the head of
the anchor provide protection against concrete spalling. These ears restrict the ring
clutch rotation during lateral pulls. As a result, lateral forces are transmitted directly to
the edge of the anchor instead of the concrete.
Fleet-Lift System
The body of the erection anchor is shaped to allow full reinforcement for secure support
and spall-free rotation.
P92P Erection Anchors are available plain or hot-dipped galvanized.
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.
Example:
200, P92P Fleet-Lift Erection Anchor with Shear
Plate, FL148, hot-dipped galvanized.
Safe Working
Load
Product Code
FL147
FL148
FL149
2-1/2"
3/4"
3"
2-1/2"
1-1/4"
3"
3"
1-5/8"
3-1/2"
(Tons)
Anchor dimensions not shown are the same as the P92 Erection Anchor of
the same load range.
Shear Reinforcement
Stress is caused during the edge lifting of a precast panel, making supplemental
reinforcement around the anchor necessary in thin panels. The Fleet-Lift P92P
Erection Anchor with integral Shear Plate is designed expressly for this purpose.
Install the anchor so that the shear plate is opposite the direction of lift.
Tension Reinforcement
The P92P with Shear Plate Fleet-Lift Erection Anchor is manufactured with a
steel tension pin that resists pullout during normal erection situations. The safe
working load chart on the following page lists two sets of tension values. If the
higher safe working load is used, the anchor must be properly reinforced using
the P60T Tension Bar. The tension bar should be placed through the lower hole.
44
Typical P92P
FleetLift
Erection
Anchor with
Shea Plate
Application
Direction of Lift
11/12
Fleet-Lift System
P92P Fleet-Lift Erection Anchor with Shear Plate Capacities
P92 Fleet-Lift
Erection Anchor
Product
Code
Precast Concrete
Panel Thickness
FL147
3-1/2" Min.
1,450 lbs.
2,575 lbs.
4,000 lbs.
FL147
4"
1,625 lbs.
2,575 lbs.
4,000 lbs.
FL147
5"
2,050 lbs.
3,350 lbs.
4,000 lbs.
FL147
6"
2,350 lbs.
3,750 lbs.
4,000 lbs.
FL147
7"
2,625 lbs.
3,850 lbs.
4,000 lbs.
FL147
8"
2,850 lbs.
4,000 lbs.
4,000 lbs.
FL147
9"
3,050 lbs.
4,000 lbs.
4,000 lbs.
FL147
10"
3,225 lbs.
4,000 lbs.
4,000 lbs.
FL147
11"
3,425 lbs.
4,000 lbs.
4,000 lbs.
FL147
12"
3,675 lbs.
4,000 lbs.
4,000 lbs.
FL148
4" Min.
2,150 lbs.
3,450 lbs.
8,000 lbs.
FL148
5"
2,625 lbs.
4,250 lbs.
8,000 lbs.
FL148
6"
3,100 lbs.
5,075 lbs.
8,000 lbs.
FL148
7"
3,525 lbs.
5,825 lbs.
8,000 lbs.
FL148
8"
3,925 lbs.
6,600 lbs.
8,000 lbs.
FL148
9"
4,275 lbs.
7,350 lbs.
8,000 lbs.
FL148
10"
4,600 lbs.
8,000 lbs.
8,000 lbs.
FL148
11"
4,900 lbs.
8,000 lbs.
8,000 lbs.
FL148
12"
5,150 lbs.
8,000 lbs.
8,000 lbs.
FL149
6" Min
4,000 lbs.
5,580 lbs.
16,000 lbs.
FL149
7"
4,250 lbs.
6,870 lbs.
16,000 lbs.
FL149
8"
4,475 lbs.
7,775 lbs.
16,000 lbs.
FL149
9"
4,725 lbs.
8,300 lbs.
16,000 lbs.
FL149
10"
4,950 lbs.
8,800 lbs.
16,000 lbs.
FL149
11"
5,200 lbs.
10,000 lbs.
16,000 lbs.
FL149
12"
5,450 lbs.
11,300 lbs.
16,000 lbs.
Fleet-Lift System
(ton x length)
Notes:
1) Safe Working Loads are based on approximately a 4 to 1 factor of safety in 3,500 psi normal weight concrete.
2) FL449 uses 8-10T P99 Recess and P91 Ring Clutch.
11/12
45
Fleet-Lift System
P92DP Fleet-Lift Erection Anchor with Shear Plate and Shear Pin DS_P92DP
The Dayton Superior P92DP Fleet-Lift Erection Anchor with a Shear Plate and
a Shear Pin is similar to the P92P anchor with the addition of a shear pin. By
welding a solid shear pin opposite the shear plate, the anchor can resist shear
loads in both directions.
Solid
Shear Pin
F
C
P92DP Erection Anchors are available either plain or hot-dipped galvanized steel.
To Order:
Shear
Plate
Example:
200, P92DP Fleet-Lift Erection Anchor with Shear Plate/
Pin, FL744, 4/6-ton system size, hot-dipped galvanized.
Load Range
Product Code
FL647
FL648
FL649
(Tons)
2-1/2"
3/4"
3"
1/4"
1/2"
2-3/4"
2-1/2"
1-1/4"
3"
3/4"
3/4"
2-7/8"
3"
1-5/8"
3-1/2"
3/4"
3/4"
2-7/8"
Anchor dimensions not shown are the same as the P92 Erection Anchor of the same load range.
Tension Reinforcement
The P92DP Fleet-Lift Erection Anchor is manufactured with a steel tension pin that resists pullout during normal erection
situations. The safe working load chart on the following page lists two sets of tension values. If the higher safe working
load is used, the anchor must be properly reinforced using the P60T Tension Bar. The tension bar should be placed through
the lower hole of the anchor.
46
11/12
Fleet-Lift System
P92 Fleet-Lift
Erection Anchor
Product
Code
Precast
Concrete Panel
Thickness
Shear Safe
Working Load for
Primary Shear
Shear Safe
Working Load for
Secondary Shear
Tension Safe
Working Load
Anchor Only
Tension Safe
Working Load
With Tension Bar
FL647
3-1/2" Min.
1,450 lbs.
1,150 lbs.
2,575 lbs.
4,000 lbs.
FL647
4"
1,625 lbs.
1,300 lbs.
2,575 lbs.
4,000 lbs.
FL647
5"
2,050 lbs.
1,650 lbs.
3,350 lbs.
4,000 lbs.
FL647
6"
2,350 lbs.
1,750 lbs.
3,750 lbs.
4,000 lbs.
FL647
7"
2,625 lbs.
1,875 lbs.
3,850 lbs.
4,000 lbs.
FL647
8"
2,850 lbs.
2,100 lbs.
4,000 lbs.
4,000 lbs.
FL647
9"
3,050 lbs.
2,275 lbs.
4,000 lbs.
4,000 lbs.
FL647
10"
3,225 lbs.
2,450 lbs.
4,000 lbs.
4,000 lbs.
FL647
4,000 lbs.
(ton x length)
11"
3,425 lbs.
2,575 lbs.
4,000 lbs.
FL647
12"
3,675 lbs.
2,950 lbs.
4,000 lbs.
4,000 lbs.
FL648
4" Min.
2,150 lbs.
1,725 lbs.
3,450 lbs.
8,000 lbs.
FL648
5"
2,625 lbs.
2,100 lbs.
4,250 lbs.
8,000 lbs.
FL648
6"
3,100 lbs.
2,475 lbs.
5,075 lbs.
8,000 lbs.
FL648
7"
3,525 lbs.
2,825 lbs.
5,825 lbs.
8,000 lbs.
FL648
8"
3,925 lbs.
3,150 lbs.
6,600 lbs.
8,000 lbs.
FL648
9"
4,275 lbs.
3,425 lbs.
7,350 lbs.
8,000 lbs.
FL648
10"
4,600 lbs.
3,675 lbs.
8,000 lbs.
8,000 lbs.
FL648
11"
4,900 lbs.
3,925 lbs.
8,000 lbs.
8,000 lbs.
FL648
12"
5,150 lbs.
4,125 lbs.
8,000 lbs.
8,000 lbs.
16,000 lbs.
FL649
6" Min.
4,000 lbs.
3,200 lbs.
5,580 lbs.
FL649
7"
4,250 lbs.
3,400 lbs.
6,870 lbs.
16,000 lbs.
FL649
8"
4,475 lbs.
3,575 lbs.
7,775 lbs.
16,000 lbs.
FL649
9"
4,725 lbs.
3,775 lbs.
8,300 lbs.
16,000 lbs.
FL649
10"
4,950 lbs.
3,975 lbs.
8,800 lbs.
16,000 lbs.
FL649
11"
5,200 lbs.
4,150 lbs.
10,000 lbs.
16,000 lbs.
FL649
12"
5,450 lbs.
4,350 lbs.
11,300 lbs.
16,000 lbs.
Fleet-Lift System
P92DP Fleet-Lift Erection Anchor with Shear Plate and Shear Pin Capacities
Notes:
1) Safe Working Load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2) Install anchors as shown on preceding page to develop safe working loads in chart.
11/12
47
Fleet-Lift System
P92FE Fleet Lift Forged Erection Anchor DS_P92FE
The Dayton Superior P92FE Forged Erection Anchor is specifically designed to provide greater lifting
capacities for horizontal to vertical edge lifts. The anchors are forged to provide 20% greater safe working
loads. The head of the anchor is designed with two protrusions or "ears" on the head of the anchor which
provide protection against concrete spalling. These protrusions restrict the ring clutch rotation during lateral
pulls. As a result, lateral forces are transmitted directly to the edge of the anchor instead of the concrete.
The P92FE Forged Erection Anchor utilizes the Fleet P91S or Fleet P91NC lifting hardware and the P99 Recess Plugs.
P92FE Forged Erection Anchors are available in plain or hot-dipped galvanized finishes.
Fleet-Lift System
P92FE Capacity
Product Code
(Plain)
Product Code
(Galvanized)
3-Ton
126748
127518
6-Ton
143420
143421
10-Ton
143422
143423
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.
Example:
200, P92FE Fleet-Lift Forged Erection Anchors,
#126748, hot-dipped galvanized.
P92FE Forged Erection Anchor
Ton x Length
3-ton x 8"
6-ton x 10-3/8"
10-ton x 12-3/4"
Slab Thickness
Insert Height
Minimum
Edge Distance
Minimum
Corner
Distance
Shear
SafeWorking
Loadwith
Shear Bar
Tension Safe
Working Load
Anchor Only
Tension Safe
Working Load
with Tension
Bar
4" Min.
8"
2"
12"
1,390lbs.
2,500lbs.
6,000lbs.
5"
8"
2-1/2"
12"
1,680lbs.
3,130lbs.
6,000lbs.
6"
8"
3"
12"
1,980lbs.
3,760lbs.
6,000lbs.
7"
8"
3-1/2"
12"
2,300lbs.
4,380lbs.
6,000lbs.
8"
8"
4"
12"
2,630lbs.
5,010lbs.
6,000lbs.
9"
8"
4-1/2"
12"
2,980lbs.
5,640lbs.
6,000lbs.
10"
8"
5"
12"
3,340lbs.
6,000lbs.
6,000lbs.
11"
8"
5-1/2"
12"
3,720lbs.
6,000lbs.
6,000lbs.
12"
8"
6"
12"
4,110lbs.
6,000lbs.
6,000lbs.
5-1/2"Min.
10-3/8"
2-3/4"
16"
2,840lbs.
4,720lbs.
12,000lbs.
6"
10-3/8"
3"
16"
3,030lbs.
5,150lbs.
12,000lbs.
7"
10-3/8"
3-1/2"
16"
3,430lbs.
6,010lbs.
12,000lbs.
8"
10-3/8"
4"
16"
3,840lbs.
6,870lbs.
12,000lbs.
9"
10-3/8"
4-1/2"
16"
4,270lbs.
7,730lbs.
12,000lbs.
10"
10-3/8"
5"
16"
4,710lbs.
8,590lbs.
12,000lbs.
11"
10-3/8"
5-1/2"
16"
5,010lbs.
9,450lbs.
12,000lbs.
12"
10-3/8"
6"
16"
5,540lbs.
10,310lbs.
12,000lbs.
7 1/2"
12-3/4"
3-3/4"
19"
4,180lbs.
7,920lbs.
20,000lbs.
8"
12-3/4"
4"
19"
4,420lbs.
8,440lbs.
20,000lbs.
9"
12-3/4"
4-1/2"
19"
4,920lbs.
9,500lbs.
20,000lbs.
10"
12-3/4"
5"
19"
5,430lbs.
10,560lbs.
20,000lbs.
11"
12-3/4"
5-1/2"
19"
5,950lbs.
11,610lbs.
20,000lbs.
12"
12-3/4"
6"
19"
6,490lbs.
12,670lbs.
20,000lbs.
Safe Working Load provides a factor of safety approximately 4 to 1 in 3,500 psi normal weight concrete.
48
11/12
Fleet-Lift System
P92FEW Fleet Lift Forged Erection Anchor with Sheer Plate DS_P92FEW
P92FEW
Capacity
Product Code
(Plain)
Product Code
(Galvanized)
3 Ton
129473
139577
6 Ton
143424
143425
10 Ton
143426
143427
Fleet-Lift System
The P92FEW Forged Erection Anchor with Shear Plate eliminates the need for a shear bar. The P92FE
and P92FEW anchors are stocked in a plain finish and can be galvanized locally.
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.
Example:
200, P92FEW Fleet-Lift Forged Erection Anchors,
#139577, hot-dipped galvanized.
3 Ton x 8"
6 Ton x 10-3/8"
10 Ton x 12-3/4"
Slab Thickness
Minimum Edge
Distance
Minimum
Corner Distance
Shear Safe
Working Load
with Shear Plate
Tension Safe
Working Load
Anchor Only
Tension Safe
Working Load
with Tension
Bar
4"
2"
12"
1,800lbs
6,000lbs
6,000lbs
5"
2-1/2"
12"
2,300lbs
6,000lbs
6,000lbs
6"
3"
12"
2,800lbs
6,000lbs
6,000lbs
7"
3-1/2"
12"
3,400lbs
6,000lbs
6,000lbs
8"
4"
12"
4,000lbs
6,000lbs
6,000lbs
9"
4-1/2"
12"
4,400lbs
6,000lbs
6,000lbs
10"
5"
12"
4,800lbs
6,000lbs
6,000lbs
11"
5-1/2"
12"
5,200lbs
6,000lbs
6,000lbs
12"
6"
12"
5,700lbs
6,000lbs
6,000lbs
5-1/2"
2-3/4"
16"
3,100lbs
10,000lbs
12,000lbs
6"
3"
16"
3,250lbs
10,500lbs
12,000lbs
7"
3-1/2"
16"
3,700lbs
11,500lbs
12,000lbs
8"
4"
16"
4,040lbs
12,000lbs
12,000lbs
9"
4-1/2"
16"
4,600lbs
12,000lbs
12,000lbs
10"
5"
16"
5,000lbs
12,000lbs
12,000lbs
11"
5-1/2"
16"
5,500lbs
12,000lbs
12,000lbs
12"
6"
16"
6,100lbs
12,000lbs
12,000lbs
7-1/2"
3-3/4"
19"
4,600lbs
17,500lbs
20,000lbs
8"
4"
19"
4,800lbs
18,000lbs
20,000lbs
9"
4-1/2"
19"
5,450lbs
19,000lbs
20,000lbs
10"
5"
19"
6,100lbs
20,000lbs
20,000lbs
11"
5-1/2"
19"
6,800lbs
20,000lbs
20,000lbs
12"
6"
19"
7,600lbs
20,000lbs
20,000lbs
Safe Working Load provides a factor of safety approximately 4 to 1 in 3,500 psi normal weight concrete.
11/12
49
Fleet-Lift System
P92FEWDP Forged Erection Anchor with Shear Plate and Secondary Shear Pin
The P92FEWDP Forged Erection Anchor with Shear Plate is specifically designed to provide greater lifting
capacities for horizontal to vertical edge lifts. By welding a solid shear pin opposite the shear plate, the
anchor can resist shear loads in both directions. The anchors are forged to provide 20% greater safe working
loads. The P92FEWDP eliminates the need for a shear bar on the primary and secondary shear loading.
Fleet-Lift System
P92FEWDP
Product Code
(Plain)
Product Code
(Galvanized)
3 Ton
142881
MTO
6 Ton
142882
MTO
10 Ton
142883
MTO
PRODUCT APPLICATION:
The P92FEWDP Forged Erection Anchor with Shear Plate and Secondary Shear Pin is designed specifically for
edge tilting precast concrete elements from the horizontal to vertical position. When the panel is placed on
an A frame or is required to be rotated 180, the addition of the shear pin works with the shear plate to
resist the shear load in the opposite direction of the shear plate. The shear pin helps to protect the concrete from spalling
when the shear loads are applied in a secondary direction.
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.
Example:
200, P92FEWDP 3-Tonx8" Fleet-Lift Forged
Erection Anchor with Shear Plate and Secondary
Shear Pin, 142881, plain finish.
INSTALLATION:
The P92FEWDP anchor is set in the form with the shear plate in the down position to resist the primary shear load.
Shear Safe
Working Load
Secondary
Shear
Tension Safe
Working Load
Anchor Only
Tension Safe
Working Load
with Tension Bar
Product Code
142881
4"
1,800 lbs
1,390 lbs
6,000 lbs
6,000 lbs
3 Ton x 8"
142881
8"
4,000 lbs
3,000 lbs
6,000 lbs
6,000 lbs
142881
12"
5,700 lbs
4,425 lbs
6,000 lbs
6,000 lbs
142882
5-1/2"
3,100 lbs
2,560 lbs
10,000 lbs
12,000 lbs
142882
8"
4,040 lbs
3,660 lbs
12,000 lbs
12,000 lbs
142882
12"
6,100 lbs
5,600 lbs
12,000 lbs
12,000 lbs
6 Ton x 10-3/8"
10 Ton x 12-3/4"
Slab Thickness
Shear Safe
Working Load
Primary Shear
Ton x Length
142883
7-1/2"
4,600 lbs
3,630 lbs
17,500 lbs
20,000 lbs
142883
10"
6,100 lbs
4,900 lbs
20,000 lbs
20,000 lbs
142883
12"
7,600 lbs
6,520 lbs
20,000 lbs
20,000 lbs
Safe working load provides a factor of safety approximately 4 to 1 in 3.500 psi normal weight concrete
50
11/12
Fleet-Lift System
P92H Fleet-Lift Two-Hole Erection Anchor DS_P92H, DS_P92HP
P92HP Fleet-Lift Two-Hole Erection Anchor with Shear Plate
Fleet-Lift Two-Hole Erection Anchors combine the strength, spall
resistance and high tension performance of the P92 Erection Anchor.
A
A
The P92H Two-Hole Erection Anchor was designed for use where the
lift direction applies a tension load ONLY to the anchor. A properly
installed P98T Tension Bar is always required when using this erection
anchor. For shear applications the P98S Shear Bar is designed to fit
over the P92H. The design of the shear bar allows it to fit over the top
edge of the anchor. It is placed in the top notch and secured so that it
bears tightly against the bottom of the notch. Accurate placement of
the shear bar provides for spall-free edge lifting.
Fleet-Lift System
B
F
To Order:
Example:
200, P92H Fleet-Lift Two-Hole Erection Anchor,
FL075, hot-dipped galvanized.
P92H
Fleet-Lift
Two-Hole Erection
Anchor
Product
Code
P92HP
Two-Hole Erection
Anchor
w/ Shear Plate
Product
Code
(ton x length)
(ton x length)
FL403
2"
4-1/4"
3/8"
FL423
2-1/2"
3"
1/4"
FL903
2"
8-1/4"
3/8"
FL403L
2-1/2"
3"
1/4"
FL075
2-1/2"
7-7/8"
5/8"
FL275
2-1/2"
3"
3/8"
FL975
2-1/2"
10-7/8"
5/8"
FL175L
2-1/2"
3"
3/8"
FL185L
3-3/4"
13-1/4"
3/4"
FL285L
3"
3-1/2"
3/8"
Anchor dimensions not shown are the same as the P92 Erection Anchor of the same load range.
Shear Reinforcement
Stress is caused during the edge lifting of a precast
concrete panel, making supplemental reinforcement
around the anchor necessary in thin panels. The FleetLift P92HP Erection Anchor with integral Shear Plate is
designed expressly for this purpose. Install the anchor
so that the shear plate is opposite the direction of lift.
Direction of Lift
Tension Reinforcement
The P92HP Fleet-Lift Erection Anchor with Shear
Plate must be properly reinforced using the P60T
Tension Bar. The tension bar should be placed
through the lower hole.
11/12
51
Fleet-Lift System
P92H Fleet-Lift Two-Hole Erection Anchor and
P92HP Fleet-Lift Two-Hole Erection Anchor with Shear Plate Capacities
P92H or P92HP
Fleet-Lift Two-Hole
Erection Anchor
Product
Code
Precast Concrete
Panel Thickness
P92HP With
Shear Plate Safe
Working Load
3-1/2" Min.
1,325 lbs.
4"
1,525 lbs.
5"
1,525 lbs.
(ton x length)
Fleet-Lift System
FL403
FL423
FL403
FL423
FL403
FL423
P92H or P92HP
Tension Safe
Working Load With
Tension Bar
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
FL403
FL423
6"
1,750 lbs.
4,000 lbs.
4,000 lbs.
FL403
FL423
7"
1,900 lbs.
4,000 lbs.
4,000 lbs.
FL403
FL423
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL975
FL175L
FL185L
FL285L
4,000 lbs.
4,000 lbs.
4,000 lbs.
4"
1,650 lbs.
4,000 lbs.
4,000 lbs.
5"
1,875 lbs.
4,000 lbs.
4,000 lbs.
6"
2,125 lbs.
4,000 lbs.
4,000 lbs.
7"
2,400 lbs.
4,000 lbs.
4,000 lbs.
8"
2,700 lbs.
4,000 lbs.
4,000 lbs.
9"
2,925 lbs.
4,000 lbs.
4,000 lbs.
10"
3,275 lbs.
4,000 lbs.
4,000 lbs.
11"
3,575 lbs.
4,000 lbs.
4,000 lbs.
12"
3,975 lbs.
4,000 lbs.
8,000 lbs.
5-1/2" Min.
2,025 lbs.
8,000 lbs.
8,000 lbs.
6"
2,250 lbs.
8,000 lbs.
8,000 lbs.
7"
2,600 lbs.
8,000 lbs.
8,000 lbs.
8"
3,000 lbs.
8,000 lbs.
8,000 lbs.
9"
3,375 lbs.
8,000 lbs.
8,000 lbs.
10"
3,750 lbs.
8,000 lbs.
Same panel thickness and SWLs as FL048
Same panel thickness and SWLs as FL148
Same panel thickness and SWLs as FL049
Same panel thickness and SWLs as FL149
8"
2,075 lbs.
Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Dayton Superior recommends the use of the P90HP Fleet-Lift Anchor when shear loads will be encountered.
52
11/12
Fleet-Lift System
P92S Fleet-Lift Sandwich Panel Erection Anchor DS_P92S, DS_P92SP
P92SP Fleet-Lift Sandwich Panel Erection Anchor with Shear Plate
The Fleet-Lift Sandwich Panel Erection Anchor is designed to erect precast,
insulated sandwich panels with a minimum loss of insulation. The anchor
uses standard Fleet-Lift recess plugs and ring clutches.
The design of the anchor allows it to distribute anchor loads evenly to both
concrete wythes. This is accomplished by the use of two specially bent rebars
per sandwich panel anchor. The sandwich panel erection anchor, with its
unique anchor head shape, in combination with the two bent rebars, transfers
both the anchors shear and tension loads evenly into each of the concrete
wythes.
Place one bent rebar through the anchors top hole and the second rebar
through the anchors bottom hole. The rebar extend from the anchor into the
top and bottom wythe of concrete. The two specially bent rebar must be used
with the sandwich panel erection anchor to achieve the safe working loads
shown.
A
F
Both the P92S and P92SP anchors are available in plain or hot-dipped
galvanized finish.
To
p
In
Bo
yt
tto
su
he
lat
Parallel to Thickness
io
yt
he
To Order:
Perpendicular to Thickness
Example:
Anchor
Tonnage
Product
Code
Shear
Plate
4-ton
4-ton
4-ton
8-ton
8-ton
10-ton
10-ton
10-ton
10-ton
FL220
FL077
FL230
FL184
FL284
128242
128243
127351
127350
Yes
No
Yes
No
Yes
No
No
Yes
Yes
4"
6"
6"
6"
6"
7"
8"
7"
8"
3-3/4"
3-3/4"
3-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"
2-3/8"
4-3/8"
4-3/8"
4-3/8"
4-3/8"
5"
6"
6"
6"
2-1/16"
1-13/16"
1-13/16"
3-3/8"
3-3/8"
3-3/8"
3-3/8"
3-3/8"
3-3/8"
5/8"
5/8"
5/8"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3"
3"
3"
8"
8"
2"
2"
3-1/2"
3"
3"
11/12
53
Fleet-Lift System
The P92S Sandwich Panel Erection Anchor is designed for use with 2", 3" and
4" thick insulated sandwich panels.
Fleet-Lift System
Anchor Product
Code
FL077
FL220
FL184
FL284
127351 127350
3"
Rebar
#4 Grade 60 x 34" overall
#5 Grade 60 x 42" overall
#5 Grade 75 x 50" overall
2"
Fleet-Lift System
3"
Min. Radius
Detail A
5/8"
Overall
Length
4"
8"
2"
30
32"
Detail A
3"
30
3"
For
Anchor
4-ton
4-ton
8-ton
8-ton
8-ton
8-ton
10-ton
10-ton
FL077
FL077
FL184
FL184
FL284
FL284
127351
127350
Concrete
Compressive
Strenth
4,500 psi
3,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi
Insulated
Panel
Thickness
2" x 2" x 4"
3" x 2" x 3"
3" x 2" x 3"
2" x 2" x 4"
4" x 2" x 2"
3" x 2" x 3"
3" x 3" x 3"
3" x 4" x 3"
Shear Parallel
to Thickness
3,300lbs
3,425lbs
3,850lbs
3,450lbs
4600lbs
4,400lbs
4,700lbs
4,400lbs
Shear
Perpendicular
to Thickness
8,000lbs
8,000lbs
9,900lbs
10,500lbs
9,870lbs
8,800lbs
10,900lbs
9,200lbs
Tension
8,000lbs
8,000lbs
16,000lbs
16,000lbs
15,400lbs
15,400lbs
20,000lbs
20,000lbs
54
11/12
Fleet-Lift System
P92AH Fleet-Lift Erection Anchor with 45 Head with Shear Plate
The Dayton Superior P92AH Fleet-Lift Erection Anchor with
45 Head and Shear Plate is designed for use when the
lifting edge is beveled at a 45 angle. The factory installed
shear plate eliminates the need for any additional shear
reinforcement.
C
45
Installation
To install the P92AH anchor, position the anchor a minimum
of 3/4" and a maximum of 1-1/2" clear of the casting
bed. This can be accomplished using any of the standard
recess members. After the anchor has been secured in
place, tension reinforcement may be added, if desired.
After the concrete has set, removal of the edge form and
recess member will expose the head of the anchor for easy
attachment of the lifting eye.
Tension Reinforcement
Due to the geometry of the anchor the loads shown in the
table should not be exceeded, even if additional tension
reinforcement is present.
P92AH Erection Anchors are available plain, or hot-dipped
galvanized.
Fleet-Lift System
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.
Example:
200, P92AH, Fleet-Lift Erection Anchor with 45
head, FL454, hot-dipped galvanized.
DS_P92AH
Chamfer
45
Shear Lift
Tension Lift
P92AH
Fleet-Lift
Erection Anchor
Product
Code
Precast
Concrete
Panel
Thickness
Shear Safe
Working
Load for
Shear
FL452
5" Min.
1,750 lbs.
2,650 lbs.
2,650 lbs.
FL452
6"
2,150 lbs.
3,850 lbs.
3,850 lbs.
FL454
6" Min.
2,400 lbs.
5,200 lbs.
5,200 lbs.
FL454
8"
3,500 lbs.
6,200 lbs.
6,200 lbs.
FL458
8" Min.
3,500 lbs.
7,500 lbs.
7,500 lbs.
(ton x length)
2"
8-1/2"
3/8"
3-1/2"
2-1/2"
11"
5/8"
4"
3/4"
5-3/8"
3-3/4" 13-3/4"
Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Safe Working Load is based on the anchor being located in the panel so that the shear plate is 3/4" minimum to 1-1/2" maximum from
casting surface.
3. Panel will not hang plumb, as the panel thickness, center of gravity and anchor location will determine the exact angle at which the panel
will hang.
4. Due to the design of this anchor, DO NOT attempt to use this anchor at loads higher than shown in this table even with a properly
installed tension bar.
5. Anchor dimensions not shown are the same as the P92P Erection Anchor with Shear Plate of the same load range.
11/12
55
Fleet-Lift System
P93 Fleet-Lift L-Anchor DS_P93
The Dayton Superior P93 Fleet-Lift L-Anchor is a very efficient anchor. This anchor is used for both stripping and erection
carrying tension and/or shear loads (except for edge shear in thin panels). The L-Anchor produces
exceptionally high pullout strength for its size, due to its foot design.
A
The L-Anchor can be placed on the face, back, or thicker panel edge allowing for back-stripping
and their rotation from horizontal to vertical.
The P93 anchor is available in plain or hot-dipped galvanized finish. This anchor requires the use
of the 2/5-ton range ring clutch and the 2/3-ton load range recess plug.
Fleet-Lift System
To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) finish.
D
Example:
FL050
5" Min.
12"
2,000 lbs.
2,000 lbs.
1-1/4"
4"
1-7/16" 3/16"
Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Anchor is not designed for use in thin edge shear conditions.
3. Anchor must use FL051 (P99) Reusable Recess Plug
P94 Fleet-Lift
L-Anchor
(ton x length)
Precast
Concrete
Product Minimun
Code
Panel
Thickness
To Order:
Specify: (1) quantity, (2) name,
(3) product code, (4) finish.
Example:
200, P94 Fleet-Lift T-Anchors,
FL850, hot-dipped galvanized.
Minimum
Edge or
Corner
Distance
Shear
Safe
Working
Load
Tension
Safe
Working
Load
FL110
4-3/4"
8"
4,000 lbs.
FL059
5-7/8"
11"
4,000 lbs.
FL848
4-5/8"
8-1/2"
FL849
5-1/8"
9-1/2"
FL850
5-5/8"
FL851
FL852
D
A
C
3/8"
1/2"
5,500 lbs.
5/8"
1/2"
7,100 lbs.
5/8"
1/2"
10-1/2"
8,000 lbs.
5/8"
1/2"
6-1/8"
11-1/2"
8,000 lbs.
5/8"
1/2"
6-5/8"
12-1/2"
8,000 lbs.
5/8"
1/2"
FL853
7-1/8"
13-1/2"
8,000 lbs.
5/8"
1/2"
FL854
7-5/8"
14-1/2"
8,000 lbs.
5/8"
1/2"
8,000 lbs.
5/8"
1/2"
5/8"
3/4"
3/4"
3/4"
3/4"
3/4"
FL855
8-1/8"
15-1/2"
FL319*
11-1/2"
23"
FL055
6-1/8"
12-1/4"
FL119
11-3/4"
23"
56
1/2"
1.
2.
3.
4.
3/8"
7,950 lbs.
4"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,500 psi normal weight concrete.
Side notches are provided on 4-ton T-Anchors only.
No side notches are provided on 2, 6 and 8-ton T-Anchors.
Use 8-10T P99 Recess and P91 Ring Clutch with FL319*.
P94 Fleet-Lift
T-Anchor 4-ton
B
D
P94 Fleet-Lift
T-Anchor
2, 6 and 8-ton
11/12
Fleet-Lift System
P94H Fleet-Lift H-Anchor 2-Ton DS_P94H
3.3"
The Dayton Superior Fleet-Lift H-Anchor (P94H) is unique in design simplicity. It offers
exceptional strength for lifting and handling precast elements, yet can be used in panels
as thin as 3". The P94H anchor can be easily preset in the form or wet set after the
concrete has been poured. The H-Anchor is the strongest and most economical precast
lifting anchor available for back-stripping. H-Anchors are available in plain and hot-dipped
galvanized finish.
Load
2.3"
FL523
FL524
Fleet-Lift System
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.
Example:
200, P94H Fleet-Lift H-Anchor, FL525,
hotdipped galvanized.
Optional Reinforcement
Tension
Shear
Shear
Product
Code
Load
Range
Tension
Load
4:1 SF
Tension with
Reinforcement**
4:1 SF
Shear
Load
4:1 SF
Minimum
Edge
Distance
Ultimate
Mechanical
Strength
FL523
2 Ton
2,205lbs.
2,900lbs.
2,205lbs.
8"
16,000lbs.
FL524
2 Ton
3,255lbs.
4,000lbs.
3,255lbs.
10"
16,000lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1. Table is based on a minimum concrete
compressive strength of 3,500 psi.
* When panel edge installation is required, use the H-Anchor or Two-Hole Anchor with a tension bar. Contact
Dayton Superior Technical Assistance for minimum tension reinforcement.
** #4 x 12" long placed directly at centerline and against bottom of hole. See sketches at left.
P94H Dimensions
Product
Code
Optional
Reinforcement
Minimum
Slab
Thickness
Weight
Each
B
1.25"
2.30"
.35"
.56"
3"
.28 lbs.
FL524
1.25"
3.30"
.38"
1.44"
4"
.36 lbs.
P94H
H-Anchors
are available
galvanized.
FL525
.38"and hot-dipped
1.25"
4.30" in plain
1.44"
5"
FL529
11/12
1.25"
9.30"
.38"
1.44"
10"
.53 lbs.
1.38 lbs.
3/8"
3/8"
57
Fleet-Lift System
P94S Fleet-Lift S-Anchor DS_P94S
1-1/2"
The Dayton Superior P94S Fleet-Lift S-Anchor is a high-strength, hot forged anchor that can be wet
set" or used with the optional T41 Plastic base in face-lift applications. When the P94S anchor is
used with the Fleet-Lift high capacity ring clutches, safe working loads up to 20,000 pounds can be
realized. See the chart below for appropriate anchor lengths and concrete compressive strengths.
P94S anchors are available in plain and hot-dipped galvanized.
Insert
Height
5/8"
To Order:
Fleet-Lift System
Example:
400, P94S Fleet-Lift S-Anchors, FL505
with hot-dipped galvanized finish.
1-7/8"
Type S
Type F
P94S Fleet-Lift
S-Anchor
Length (L)
3-1/2"
4"
5-1/2"
3-7/8"
4-1/8"
4-7/8"
5-1/8"
5-7/8"
6-1/8"
6-7/8"
7-7/8"
5-1/2"
7"
10"
Width (A)
1-5/16"
1-5/16"
1-5/16"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2-5/8"
2-5/8"
2-5/8"
Thickness (B)
3/8"
3/8"
3/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
3/4"
3/4"
3/4"
SWL Tension
3,900
4,400
4,510
5,000
5,370
6,560
6,970
8,250
8,700
10,070
12,000
8,500
12,500
20,000
Type
F/S
F/S
F
S
S
S
S
S
S
S
S
F
S
S
Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete Use FL062 Recess Member and FL002S Ring
Clutch (both 4-6T) with these anchors.
The Dayton Superior P95F Fleet-Lift Flat Foot Anchor is a versatile anchor that can be used
to back-strip and transport thin panels. This anchor may also be used to erect the panels.
The anchors safe working load may be increased by adding four 18" lengths of #4 rebar
as shown in the sketch.
To Order:
Example:
200, P94F Fleet-Lift Flat Foot Anchor, FL058.
#4 x 18" Long
Precast
Concrete
Minimum
Panel
Thickness
Minimum
Edge or
Corner
Distance
Shear
Safe
Working
Load
Tension
Safe
Working
Load
FL058
3-7/8"
5-1/2"
1,325 lbs.
1,325 lbs.
4,000 lbs.
4,000 lbs.
1-1/4" 2-3/4"
3/8"
4"
FL400
4-1/2"
6-3/4"
1,875 lbs.
1,875 lbs.
4,000 lbs.
4,000 lbs.
1-1/4" 3-3/8"
3/8"
4"
FL157
3-7/8"
7-1/2"
2,350 lbs.
2,350 lbs.
6,000 lbs.
6,000 lbs.
1-1/2" 3-3/4"
1/2"
4"
Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
58
11/12
Fleet-Lift System
P95P Fleet-Lift Plate Anchor DS_P95P
C
D
To Order:
Fleet-Lift System
The design of the anchor, with its wide base, permits four #4 rebar,
each 18" in length to be easily secured to the insert, as illustrated in
the sketch. The addition of the rebar increases the safe working load
of the anchor.
(FL043 only)
Example:
200, P95P Fleet-Lift Plate Anchor, FL847.
#4 x 18" Long
P95P Fleet-Lift
Plate Anchor
Product
Code
Precast
Concrete
Minimum
Panel
Thickness
Minimum
Edge or
Corner
Distance
FL128
3-3/8"
4-1/2"
950 lbs.
950 lbs.
4,000 lbs.
4,000 lbs.
FL846
4-1/8"
6"
3,575 lbs.
3,575 lbs.
6,000 lbs.
6,000 lbs.
FL847
4-5/8"
7"
4,700 lbs.
4,700 lbs.
7,000 lbs.
7,000 lbs.
1-1/2" 3-1/2"
5/8" 3-3/8"
FL044
5-5/8"
8"
4,725 lbs.
4,725 lbs.
8,000 lbs.
8,000 lbs.
1-1/2" 4-3/8"
5/8"
4"
FL043
8-1/4"
13-5/8"
11,750 lbs.
2-1/2" 6-7/8"
3/4"
3"
Shear
Safe
Working
Load
Tension
Safe
Working
Load
1-1/4" 2-1/4"
3/8"
4"
1-1/2"
5/8" 3-3/8"
3"
Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
A minimum 3/4" of concrete is required below bottom of insert to achieve load.
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required. See P98T
Fleet-Lift Tension Bar.
B
E
F
C
P96 Fleet-Lift
Two Hole Anchor
Example:
200, P96 Fleet-Lift Two-Hole Anchor, FL124.
P96 Fleet-Lift TwoHole Anchor
(ton x length)
Product
Code
FL190
FL122
4,000lbs
4,000lbs
1-1/4"
1-1/4"
2-3/4"
4"
3/8"
3/8"
9/16"
3/4"
15/16"
7/8"
9/16"
9/16"
FL124
8,000lbs
1-1/2"
5-1/2"
5/8"
7/8"
1"
11/16"
FL125
16,000lbs
2-1/2"
7"
3/4"
1-3/16"
1-1/2"
1"
Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
11/12
59
Fleet-Lift System
P96F Fleet-Lift Forged Two-Hole Anchor DS_P96F
Fleet-Lift System
The Dayton Superior P96F Fleet-Lift Forged Two-Hole Anchor is always used in conjunction
with the Dayton Superior P98T Tension Bar. The anchor has a bottom hole especially designed
to accept the tension bar. Place the P98T Tension Bar through the bottom hole in such a
manner that the ends of the tension bar are pointing downward. Fasten the tension bar tight
against the bottom side of the hole. The tension bar distributes the tension forces, developed
from the lifting process, deep into the precast concrete. This allows the lifting of very thin
and/or low concrete compressive strength panels. Do not use the P96F Two-Hole Anchor in
the following situations: 1) Without a correct size and located tension bar. 2) In the edge of
thin panels where shear loads will be applied to the anchor.
P96F Fleet-Lift
Forged TwoHole Anchor
To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required. See P98 Fleet-Lift Tension Bar.
Example:
200, P96F Fleet-Lift Forged Two-Hole Anchor, FL124.
Product
Code
22-ton
128946
44,000lbs
3.5"
11.25"
1.13"
2"
1.375"
1.75"
Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
To Order:
Specify: (1) quantity, (2) name, (3) Panel Thickness,
(4) bottom face exposed aggregate or form liner thickness.
T110 Superior Lift System
Example:
150, T110 Superior Lift Inserts, 9" Panel with " form liner panel.
Structural Panel
Thickness
Anchor
Length
SWl Tension
SWL Sheer
5"
5.5"
3.625"
4.125"
----126538
6,875lbs
7,683lbs
7,362lbs
7,958lbs
6"
4.625"
126539
8,490lbs
8,535lbs
6.5"
5.125"
126541
9,298lbs
9,095lbs
7"
5.625"
126542
10,106lbs
9,641lbs
7.5"
8"
9"
6.125"
6.625"
7.625"
126544
126545
126548
10,914lbs
11,960lbs
12,000lbs
10,175lbs
10,748lbs
12,000lbs
10"
7.875"
126549
12,000lbs
12,000lbs
Safe working load provides approximate factor of safety of 4 to 1 in 3,500 psi normal
weight concrete
60
11/12
Fleet-Lift System
P98S Fleet-Lift Shear Bar DS_P98S
The Dayton Superior P98S Fleet-Lift Shear Bar is designed and manufactured especially for use with Fleet-Lift Erection Anchors.
It is a simple, easy to use, yet very efficient design that transfers shear forces from the erection process deeper into the edge
of a precast concrete panel. It is stronger and less expensive than a shear bar fabricated from reinforcing steel.
The design of the shear bar allows it to fit over the top edge of an erection anchor. It is placed in the top notch and
secured so that it bears tightly against the bottom of the notch. Accurate placement of the shear bar provides for spallfree edge lifts.
Fleet-Lift System
The P98S Shear Bar is available to fit 2, 4 and 8-ton Fleet-Lift Erection Anchors. Available in plain or hot-dipped galvanized finish.
CL
Equal
Erection Anchor
Shear Bar
Top View
Section View
Dimensions
To Order:
Anchor
Tonnage
Product
Code
Shear Bar
Diameter
Minimum
Panel
Thickness
2-3 ton
FL140
1/2"
4"
2-1/2"
13-7/8"
Example:
4-6 ton
FL141
1/2"
5-1/2"
3-5/16"
13-7/8"
8-10 ton
FL142
1/2"
7-1/2"
4-15/16"
13-7/8"
DS_P98T
The Dayton Superior P98T Fleet-Lift Tension Bar is used with various Fleet-Lift Anchors to
provide a simple, inexpensive method of distributing tension forces (lifting) deep into a
precast member.
Anchor
Tonnage
Tension
Bar
(Grade 60)
3,000 psi
4,000 psi
5,000 psi
1-ton or 2-ton
#3
32"
28"
26"
3-ton or 4-ton
#4
44"
38"
34"
6-ton or 8-ton
#6
66"
56"
50"
10-ton
#8
110"
95"
85"
22-ton
#11
155"
134"
120"
L = Overall length of tension bar based on concrete compressive strength at time of lift.
11/12
Fasten
tension bar
tight against
the bottom
side of hole.
30
Correct
Installation of
Tension Bar
(Installed with
equal length legs.)
61
Fleet-Lift System
P99 Fleet-Lift Reusable Recess Plug DS_P99
The Dayton Superior P99 Fleet-Lift Reusable Recess Plug is molded from an
elastomeric thermal-set urethane for multiple reuse.
Embedded in the recess plug is a stainless steel stud that securely captures a
FleetLift Anchor, providing a positive connection to the form during the placement
of concrete. Attachment to the form is accomplished with a P100 Holding Rod and
P101 Fleet-Lift Holding Plate.
Fleet-Lift System
Stainless
Steel Stud
Section View
To Order:
Specify: (1) quantity, (2) name, (3) product code,.
Example:
200, P99 Fleet-Lift Reusable Recess Plug, FL062.
B
D
Anchor
Tonnage
Product
Code
1-ton
FL051
1-11/16"
1-3/4"
4-1/16"
3/16"
1-3/16"
3/8"
2-3 ton
FL200
1-11/16"
1-3/4"
4-1/16"
3/8"
1-3/16"
3/8"
4-6 ton
FL062
2-1/8"
2-5/16"
5-3/16"
5/8"
1-11/32"
3/8"
8-10 ton
FL121
3-1/8"
3-5/16"
7-13/16"
3/4"
1-31/32"
3/8"
Note: Recess Plug style FL051 is used with the 1-ton L-Anchor and 2-ton Ring Clutch combination ONLY.
P100 Fleet-Lift Holding Plate and P101 Fleet-Lift Holding Rod DS_P100
Fixed Wing Nut
DS_P101
P100 Fleet-Lift Holding Plate
Anchor
Tonnage
Product
Code
1-ton
FL160
5/8"
2-3/4"
10mm
2-2 ton
FL160
5/8"
2-3/4"
10mm
4-6 ton
FL144
1-1/4"
3-3/8"
10mm
8-10 ton
FL111
1-3/4"
4-7/8"
12mm
6"
Standard
B
Standard Thread
Recess
Product
Rod
Diameter
Plug
Code
Length and Type
Material
P101 Fleet-Lift
Holding Rod
To Order:
1, 2, 4, 6, 8 and 10-ton
Urethane
FL131
6"
3/8" Coil
1, 2, 4, 6, 8 and 10-ton
Steel
FL131C
6"
1/2" Coil
Example:
62
11/12
Fleet-Lift System
Installation and Removal of Anchors and Reusable Recess Plugs
Fleet-Lift System
Installing an Anchor in the Recess Plug: A) Open the slot of the recess plug by placing a holding rod or screwdriver into
an outside hole and squeeze the recess open. (B) Place the anchor over the steel stud and close the recess plug. The
assembly is ready for installation.
Attaching the Assembly to the Form: A) Place the assembly against the form and position over the predrilled hole. (B)
Insert the 3/8" holding rod through the hole and thread into the recess plug. (C) Pull the assembly tight to the form by
firmly tightening the wing nut on the holding rod.
B
C
Attachment Using a Holding Plate: A) Position and attach the holding plate to the form. B) Slide the anchor assembly
over the holding plate studs and firmly against the form. (C) Installation is complete.
Note: The holding plate can be used to hold the recess plug/insert assembly in the closed position to facilitate working
the anchor into fresh concrete (wet setting). It is recommended that the back of the recess plug be covered with tape to
protect it from being filled with concrete. Be sure to vibrate to properly consolidate the concrete around the anchor. To
strip, simply remove the tape and/or cover/patch and pry the holding plate out of the recess plug with a blade screwdriver
or similar tool.
B
C
Removing the Recess Plug from the Concrete: A) After the back of the recess plug is exposed, insert a steel rod or
screwdriver into the half of the recess plug opposite the threaded stud and rotate it to loosen that half of the recess plug.
(B) After the first half of the recess plug has been loosened, use the holding rod in the other side in a scissor motion to
free the recess plug.
B
11/12
63
Fleet-Lift System
P99C Fleet-Lift Cast Steel Recess Plug
The Dayton Superior P99C Fleet-Lift Cast Steel Recess Plug is
designed for high reuse, high curing temperatures and cold weather
applications. The recess Plug uses a Steel Wedge (P102) through
the anchor eye to securely hold the anchor in place. A Foam Strip
(P103) fits over the head of the anchor to prevent concrete from
entering the void.
To Order:
Specify: (1) quantity, (2) name, (3) product code.
Example:
200, P99C Fleet-Lift Cast Steel Recess Plug, FL100.
Fleet-Lift System
P102
Steel Wedge
Anchor
Tonnage
Product
Code
2- or 3-ton
FL078
1-7/8"
1-3/4"
4"
4- or 6-ton
FL100
2-3/8"
2-3/8"
5-3/8"
8- or 10-ton
FL015
3-3/8"
3-3/8"
7-3/8"
P102 Fleet-Lift
Steel Wedge
P102 Steel Wedge
P103
Foam
P103 Fleet-Lift
Foam
P103 Foam
Anchor
Tonnage
Product
Code
Anchor
Tonnage
Product
Code
2- or 3-ton
FL017
2- or 3-ton
FL087
4- or 6-ton
FL084
4- or 6-ton
FL069
8- or 10-ton
FL085
8- or 10-ton
FL091
Typical Fleet-Lift
Anchor
64
11/12
Fleet-Lift System
Installation and Removal of the Fleet-Lift Cast Steel Recess Plug
Fleet-Lift System
Installing the Cast Steel Recess Plug to an Anchor: A) Place the foam strip over the top of the anchor. (B) Place the
anchor and foam into the recess slot . (C) Slide the curved steel wedge into the top of the recess plug and through the
anchors eye and wedge tightly.
B
A
Complete Assembly
Attaching the Recess Plug/Anchor Assembly to the Form: A) Place the assembly over the predrilled hole. (B) Insert
a holding rod through the hole and thread it into the recess plug. Tighten the holding rod against the anchor with the
fixed wing nut. (C) Tighten the assembly against the form with the free-running wing nut.
Fixed
Nut
Free-Running
Nut
Removing the Cast Steel Recess Plug: A) Remove the holding rod from the recess plug. (B) Remove the form. (C)
Remove the steel wedge by tapping on the small end with a hammer. (D) Thread the holding rod back into the recess plug
and tighten until it pushes the recess out of the void.
11/12
65
Fleet-Lift System
P99D Fleet-Lift Disposable Recess Plug (PVC) DS_P99D
The Dayton Superior P99D Fleet-Lift Disposable Recess Plug can be used to preset Fleet-Lift face-lift or edge-lift anchors
or can be used to wet set P94 Anchors. The Cover/Patch fits tightly onto the recess plug to fully protect the unit. The
Cover/Patch is concrete gray in color and can be used as a patch over the recess opening for temporary or permanent cover.
Fleet-Lift System
Body
Cover/Patch
To Order:
Specify: (1) quantity, (2) name, (3) complete
sets or individual part, (4) product code.
Standard
Anchor Clip
Example:
200, P99D Fleet-Lift Disposable Recess Plug
Cover/Patches, FL067S.
Cover/Patch
Standard
Anchor Clip
Body
Anchor
Tonnage
1,2 and
3-ton
4 and 6-ton
8 and
10-ton
66
Product
Description
Product
Code
Body
Lid
FL066B
FL066L
2-7/16"
3/8"
4-1/4"
Set
FL066S
Body
FL067B
2-7/16"
2"
4-1/4"
5/8"
Lid
FL067L
2-7/8"
5-1/2"
Set
FL067S
2-7/8"
2-1/2"
5-1/2"
Body
FL068B
3/4"
Lid
FL068L
3-7/8"
8-5/16"
Set
FL068S
3-7/8"
3-1/2"
8-5/16"
11/12
Fleet-Lift System
Installation of P99D Disposable Recess
Plug and Erection Anchors
Remove the Clip
(A) Remove the clip from the recess plug. The clip will not be
used with the erection anchor. (B) Open the body of the recess
plug enough to allow the anchor to slide into the recess plug.
(C) Close the recess plug around the anchor. Recess plug/anchor
assembly is completed.
Clip Removed
Ready for Erection
Type Anchor
1B)
Remove stud
with drill
Double-Faced Tape
11/12
67
Fleet-Lift System
Fleet-Lift System
Installation of P99D Disposable Recess Plug
and Standard Anchors
Installing Standard Anchors in the Disposable Recess Plug:
Fleet-Lift System
Installing an Anchor
Support
Top of Concrete
Edge
Form
WetSet
Nail or
Double-face Tape
68
11/12
Fleet-Lift System
P99D Temporary Cover/Patch Installation
Support Rim:
use silicone
adhesive on
this area for
permanent or
water tight patch
Reinstalled as a temporary or
permanent patch
T-Anchor
Reusable Plastic
Recess Plug
Disposable
Cover/
Patch
11/12
69
Fleet-Lift System
The Dayton Superior P99-D Cover/Patch can be used as a temporary cover to keep
sand, rain, snow, debris, etc., out of the recess. Under normal precast plant yard
conditions, it will stay in place without adhesive.
Fleet-Lift System
P99P Fleet Patch DS_P99P
The Dayton Superior P99P Fleet Patch is a durable plastic patch designed to
quickly cover 2-ton and 4-ton Fleet-Lift setting plug recesses. The P99P patch
is fabricated from an additive stabilized polypropylene to maintain the patchs
slightly convex shape. The convex shape helps to keep a constant gripping
pressure after installation. The patch is supplied in a concrete gray color with a
matte finish that allows subsequent painting, if desired.
The P99P Fleet Patch is a high quality, one piece plastic patch that is easy
to install and maintain. It will provide a quick and economical solution to
covering Fleet-Lift anchor recesses.
P99P Fleet Patch
Fleet Patch
2) Push the patch onto the anchor and flush with the concrete.
Note: The P99P Fleet Patch will not prevent corrosion or rusting of an embedded anchor that is subject to wet conditions. Spraying the anchor with a corrosion resistant compound and applying a bead of silicone around the underside
of the patch will help prevent moisture penetration.
Sales
Category
Product
Code
Weight for
100
P99P
FL612
24 lbs.
To Order:
Specify: (1) quantity, (2) name, (3) product code.
Example:
200, P99P Fleet Patch, FL612.
70
11/12
Fleet-Lift System
P100M Fleet-Lift Magnetic Plate
Setting Stud
The Dayton Superior P100M Fleet-Lift Magnetic Plate eliminates the need for
drilling setting-bolt holes in steel forms. Installed into a rubber base is a set of
strong, reliable magnets. These magnets, along with an attachment stud and
setting screw, work together to hold a Fleet-Lift anchor tightly in position during
the placement of concrete.
DS_P100M
P100M Fleet-Lift
Magnetic Plate
P100MS Setting
Screw
11/12
71
Fleet-Lift System
The P100M Magnetic Plate is available in three sizes to fit the three P99 Fleet-Lift
Recess Plugs.
72
11/12
Utility Anchor
Utility Anchor System
The Dayton Superior Utility Anchor System is designed to economically simplify
the lifting and handling of precast concrete elements. Its economics, ease of
use and versatility will be a welcome addition to your precast operations.
Key Advantages
Added Benefit
Utility Anchor
Lifting System
Utility contractors can use the utility anchor effectively as a pulling iron. When
used as a pulling iron, the safe working loads may be increased by 33%, based
on the use of a 3 to 1 factor of safety.
The design of the Dayton Superior Utility Anchor Utility System assures the
precaster of an economical, user-friendly system for lifting and handling
precast concrete elements.
The precaster is able to do it all without the need for any special lifting equipment or hardware. Simply use a standard
hook or shackle to connect slings to the utility anchor for a safe lift.
The Utility Anchor System uses a polyurethane recess plug to create a void in the concrete. The concrete void created for
the P75H utility anchor is sufficiently large to accept the following:
1. 6-ton Grade 8 alloy hook or
2. 7-ton forged alloy shackle
For the P75S Utility Anchors:
3. 15-ton cast/alloy hook or
4. 15-ton forged alloy shackle
DO NOT use larger hooks or shackles; they will apply additional and unintended loads to the utility anchor and could cause
a premature failure of the concrete or anchor.
Anchor Placement
Placement of the Utility Anchor is dependent on the structural shape of the
precast element. Utility anchors are not designed for thin edge installation.
Always maintain minimum edge distances. For special conditions, contact the
nearest Dayton Superior Technical Service Department for assistance.
Lift
Lift
Lift
Pulling
Iron
Typical
Applications
Minimum
Edge
Distance
Used To Load/Install
11/12
73
Utility Anchor
P75 and P75H Utility Anchor DS_P75_P75H
The Dayton Superior Utility Anchors are available in three diameters and a series of lengths
for specific concrete thickness. The utility anchor can be set in either a 90 or a 45 anchor
orientation using the appropriate setting plug.
P75
P75H
Type
Product
Code No.
End
Shape
4UA444
121877
5-1/4"
3-1/8"
0.444"
Swift Lift
5UA444
123442
6"
3-3/4"
0.444"
Swift Lift
6UA444
121888
7-3/8"
4-3/4"
0.444"
Swift Lift
5UA671
123441
6-7/16"
3-3/4"
0.671"
Swift Lift
6UA671
121889
7-3/8"
4-3/4"
0.671"
Swift Lift
8UA671
121891
9-3/4"
6-3/4"
0.671"
Swift Lift
12UA875
124738
15-7/8"
11"
0.875"
Swift Lift
Utility Anchor
Lifting System
P75H
Type
Product
Code
No.
Minimum
Panel
Thickness
Safe Working
Load Tension
90
Safe
Working
Load Shear
90
Safe Working
Load Tension/
Shear 45
Minimum
Edge
Distance
4UA444
121877
4"
3,200
5,800
2,260
9"
5US444
123442
5"
3,860
7,710
2,730
10"
6UA444
121888
5-5/8"
4,460
9,460
3,150
12"
Anchor
P75
5UA671
123441
5"
4,560
8,430
3,220
10"
6UA671
121889
5-5/8"
7,320
15,780
5,170
12"
8UA671
121891
7-5/8"
10,830
18,850
7,660
16"
12UA875
124738
12"
24,000
24,000
24,000
30"
Note:
1. Compressive strength of normal weight concrete to be 4,000 psi at time of initial lift.
2. Safe working loads provide an approximate factor of safety of 4 to 1.
3. Utility anchors to be installed at 90 to surface of the concrete.
4. Shear safe working loads are based on loading in the direction of the top of the precast concrete element.
To Order:
Specify: (1) quantity, (2) name, (3)
product code.
Example:
200, P75 Utility Anchors, 5UA444.
To Order:
Specify: (1) quantity, (2) name, (3) product code
(4) anchor size, (5) wire spacing (6) wall thickness.
Example:
200, P75C, #121443, 5UA444anchor, 9" wire
spacing, 5" wall.
Product Code
Utility
Anchor
Wire Clip
Lengths
Wall
Thickness
123443
5UA444
9"
5"
74
121890
5UA671
9"
5"
121892
6UA444
9"
6"
121893
6UA671
9"
6"
127446
8UA671
9"
8"
11/12
Utility Anchor
P76 Utility Anchor Setting Plugs
DS_P76
Product
Code No.
Length
Width
Depth
Color
90P444
123175
8.00"
3.25"
3"
Blue
45P444
123176
8.00"
3.25"
3"
Blue
90P671
123177
8.00"
3.25"
3"
Orange
90P671
127786
9.00"
4.58"
3.35"
Orange
45P671
123178
8.00"
3.25"
3"
Orange
90P875
124685
15.00"
6.13"
5"
Blue
To Order:
Specify: (1) quantity, (2) name, (3) product code.
Example:
200, P76 Utility Anchor Setting Plugs, 90P444.
90
45
DS_P76D
To Order:
Specify: (1) quantity, (2) name, (3) product code.
Example:
200, P76D, #126214.
11/12
75
Utility Anchor
Lifting System
Utility Anchor
P76M Utility Anchor Magnetic Setting Plate DS_P76M
The Dayton Superior P76M Utility Anchor Magnetic Setting Plates are available
for easy setting of utility anchors in steel precast forms.
Use 3/8" P101 Holding Rod in threaded through hole to strip magnet from steel form.
To Order:
Specify: (1) quantity, (2) name.
Threaded Through-Hole used
to release magnet from form.
Example:
200, P76M Utility Anchor Magentic Setting Plates.
The Dayton Superior P100 Utility Anchor Holding Plate and P101 Holding Rod are used
in various applications to install Utility Anchors in the form. The Holding Plate can be
nailed, screwed, welded or double-face taped to the form. The setting plug/anchor
assembly is pushed onto the projecting studs of the plate and held firmly in place through
the concrete placement.
The Holding Rod is placed through a predrilled hole in the form and into the threaded insert in
the setting plug. After fully seating the holding rod in the setting plug, the setting plug can be
pulled up tightly to the form with the holding rods free-running wing nut.
6" (Typ.)
To Order:
Specify: (1) quantity, (2) name, (3) anchor diameter.
Example:
200, P100 Utility Anchor Holding Plates, 0.671
anchor diameter.
To Order:
Specify: (1) quantity, (2) name.
Example:
200, P104 One Piece Magnetic Utility Anchor Recess.
76
11/12
Utility Anchor
Anchor Placement
Placement of the Utility Anchor is dependent on the structural shape of the precast unit and/or the manufacturers
preference. The Utility Anchors are not designed for thin edge installations. Always maintain minimum edge distances and
adjust anchor capacities if concrete strengths, other than those noted in the capacity chart, are encountered. Refer to edge
distance chart on next page.
In-Form setting:
1. Assemble setting plug and anchor.
2. Affix holding plate (nail, weld, magnetic setting plate, double-face tape) to the form.
3. Push the setting plug/anchor assembly onto the holding plate and firmly against the form.
Through-Form Setting
1. Assemble setting plug and anchor.
2. Insert holding rod through form and line up setting plug.
Wet Setting
1. Assemble setting plug holding plate and anchor.
2. Use cover/patch or duct tape to seal setting plug cavities.
3. Work the assembly down into the wet concrete until the top surface of the plug is flush with the surface of the concrete.
Place
long
stud at
top
Form
Utility Anchor
Setting Plug
Utility Anchor
Setting Plug
Utility Anchor
Holding Rod
Utility
Anchor
Utility
Anchor
Utility
Anchor Holding Plate
(8-Ton Fleet-Lift Unit)
Form
In-Form Setting
Through-Form Setting
Setting Plug
Cover/Patches
are available
Cover/Patch may be
added to this installation
if future sealing of recess
is required. Drill out one
stud of Cover/Patch to pass
holding rod through.
Holding Plate
Wet Setting
11/12
77
Utility Anchor
Lifting System
3. Finger-tighten holding rod and lock assembly in place with the running wing nut.
Utility Anchor
P77 Double Tee Anchor DS_P77
The Dayton Superior P77 Double Tee Anchor is specifically designed to provide greater lifting capabilitites for Double Tees
and other concrete products. This Anchor has the capacity of 13,500 lbs. The anchors are designed to utilize the standard
field Crosby Hooks for lifting of the Precast Product, requiring no special hardware be purchased by the precaster or
erector. The head of the anchor is 1/2" below the concrete surface to prevent rusting and to eliminate any removal of steel,
a common practice when using "strand" as an anchor. The recess member (P75D) utilized to form the void is designed to
allow up to a 30% angle on the sling to prevent spalling of the concrete from the contact with the Crosby Hook. A smaller
void is also available if sling angle and hook size are reduced. See P76D Disposable Void Former.
P77 Double Tee Anchors are available in 3 common lengths of 9-1/2, 15-1/2" and
23-1/2" All are stocked in plain finish and available in Hot-dipped galvanized finish.
Product
Code
Safe Working
Load *
126728
126726
126727
9-1/2"
15-1/2"
23-1/2"
5/8"
5/8"
5/8"
3-3/4"
4"
4"
13,500 #
13,500 #
13,500 #
Utility Anchor
Lifting System
To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) finish.
Example:
200, P77 Double Tee Anchor #126728, plain.
C
Example:
P76 Utility Anchor and Double Tee Anchor Setting Plug DS_P76
The new P76 Setting Plug is a re-usable polyurethane setting plug designed to
provide a larger recess in the concrete for the 0.671 Utility Anchors and the
Double Tee Anchors. This setting plug is 9.0" in length, 4.5" in width across the
top, and 3.3" in depth. This recess member positions the anchor at a 90 degree
angle to the surface of the concrete product. The reusable setting plug sets the
anchor approximately 1/2" below the top of the concrete. The setting plug is
attached to the form with the P101 Holding Rod and/or the P100 Holding Plate.
The P76 Setting Plug is stripped from the concrete by placing two
3/8" dia. rods into the holes provided in the plug and using a 'scissor
To Order:
action' to strip the plug from the anchor.
Specify: (1) quantity, (2) name, (3)product code.
Example:
200, P76 Utility Anchor and Double Tee Anchor
Setting Plug, #127786.
78
11/12
Utility Anchor
P110 Wire Rope Lifting System DS_P110
The Wire Rope Lifting System is an economical lifting loop for utility type structures. It is used in face lift
applications and is mucked into the surface of the concrete. The galvanized wire rope is formed in a figure
8 shape, with the ends of the rope secured by a positive swaged clamp, and a steel band at approximately
the mid point to establish the proper shape. The Wire Rope Lifting System is embedded 2/3 of its length
into the concrete. The hardware must be standard hook or clevis with a diameter at least twice the rope
diameter. Each anchor has a color-coded tag which identifies the SWL in tension of the anchor.
To Order:
Specify: (1) quantity, (2) name, (3)product code.
Example:
200, P110 Wire Rope Lifting System #127327.
Part #
Description
#127326
#127327
#127328
#127329
#127330
#127331
#127332
0.8 T
1.2 T
1.6 T
2.0 T
2.5 T
3.8 T
5.0 T
Safe Working
Load
1,600#
2,400#
3,200#
4,000#
5,000#
7,600#
10,000#
8.07"
9.06"
9.84"
11.81"
12.80"
14.57"
14.96"
3.7"
3.9"
5.1"
5.3"
5.5"
6.5"
7.6"
3.3"
3.5"
4.9"
4.9"
4.9"
5.7"
5.7"
5.7
6.6
7.1
8.7
9.4
10.7
11.1
2
2.50
2.75
3.13
3.38
3.88
3.80
0.24
0.275
0.313
0.354
0.394--0.473
0.630
Tag Color: White= 0.8T, Red= 1.2T, Pink= 1.6T, Light Green= 2.0T,
Dark Gray= 2.5T, Emerald Green= 3.8T, Light Yellow= 5.0T
Wire Loop Parellel To Wall Thickness
Anchor
Tonnage
0.8 ton
1.2 ton
1.6 ton
2.0 ton
2.5 ton
3.8 ton
5.0 ton
Minimum
Wall
Thickness
4.0"
4.5"
4.75"
6"
7.0"
9.0"
12"
Overall
Length
Emdedment
Depth
8.0625"
9.375"
9.8125"
11.8125"
12.34"
14.5"
14.9375"
5.7"
6.5"
7"
8.7"
9.4"
10.7"
11.1"
Minimum
Edge
Distance
2.0"
2.25"
2.375"
3"
3.5"
4.5"
6"
Minimum
Corner
Distance
8.75"
9.75"
10.5"
13.25"
14.25"
16.25"
16.75"
3,000 psi
3,000 psi
4,000 psi
4,000 psi
3,500 psi
4,000 psi
3,500 psi
1,600lbs.
2,400lbs
3,200lbs
4,000lbs
5,000lbs
7,600lbs
10,000lbs
11/12
Minimum
Wall
Thickness
5.5"
6"
6.5"
7"
7.5"
9.0"
12"
Overall
Length
Emdedment
Depth
8.0625"
9.375"
9.8125"
11.8125"
12.34"
14.5"
14.9375"
5.7"
6.5"
7"
8.7"
9.4"
10.7"
11.1"
Minimum
Edge
Distance
2.75"
3"
3.25"
3.5"
3.75"
4.5"
6"
Minimum
Corner
Distance
8.75"
9.75"
10.5"
13.25"
14.25"
16.25"
16.75"
3,000 psi
3,000 psi
4,500 psi
4,000 psi
4,500 psi
6,000 psi
5,000 psi
1,600lbs.
2,400lbs
3,200lbs
4,000lbs
5,000lbs
7,600lbs
10,000lbs
79
80
11/12
Minimum
Corner
Distance
or Greater
The Dayton Superior B1 Two Strut Coil Tie and B2 Four Strut
Coil Tie, when used as inserts for lifting and handling thin wall
precast elements, are extremely effective.
Minimum
Corner
Distance
or Greater
Minimum Edge
Distance or Greater
Coil ties are available with an optional B3 Screw-on Coil for use
with the B30 Screw-on Plastic Cone to set the insert back from
the face of the concrete.
Minimum Edge
Distance or Greater
Shear
Direction
Bolt
Diameter
3/4"
3/4"
1"
1"
1 1/4"
1 1/4"
3/4"
3/4"
1"
1"
1"
1"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
Insert
Height
6"
6"
6"
6"
8"
8"
6"
6"
8"
8"
12"
12"
8"
8"
12"
12"
Minimum
Edge Distance
8"
14"
8"
16"
10"
16"
8"
12"
10"
16"
10"
15"
12"
15"
15"
20"
Minimum
Corner Distance
14"
21"
14"
24"
15"
24"
14"
16"
15"
24"
15"
22"
18"
22"
22"
30"
Safe Working
Load Tension
4,500lbs
4,500lbs
5,447lbs
6,120lbs
6,750lbs
6,750lbs
5,536lbs
6,220lbs
7,897lbs
9,000lbs
9,000lbs
9,000lbs
9,400lbs
9,400lbs
13,500lbs
13,500lbs
Safe Working
Load Shear
2,810lbs
4,500lbs
3,200lbs
6,120lbs
4,670lbs
6,750lbs
4,710lbs
6,220lbs
5,640lbs
9,000lbs
6,100lbs
9,000lbs
7,840lbs
9,390lbs
10,500lbs
13,500lbs
6"
6"
6"
6"
8"
8"
6"
6"
8"
8"
12"
12"
8"
8"
12"
12"
1 5/8"
1 5/8"
2 1/4"
2 1/4"
2 1/2"
2 1/2"
1 5/8"
1 5/8"
2"
2"
2"
2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"
0.375"
0.375"
0.440"
0.440"
0.440"
0.440"
0.375"
0.375"
0.375"
0.375
0.375"
0.375"
0.440"
0.440"
0.440"
0.440"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
NOTE: Contact Dayton Superior Technical Assitance for shear loads for inserts located near
an edge smaller than in the table.B1 or B2 Coil Ties
B
Insert
Type
B1
B1
B1
B2
B2
B2
B2
B2
Bolt
Diameter
3/4"
1"
1 1/4"
3/4"
1"
1"
1 1/4"
1 1/4"
Insert
Height
6"
6"
8"
6"
8"
12"
8"
12"
6"
6"
8"
6"
8"
12"
8"
12"
1 5/8"
2 1/4"
2 1/2"
1 5/8"
2"
2"
2 1/2"
2 1/2"
0.375"
0.440"
0.440"
0.375"
0.375"
0.375"
0.440"
0.440"
NOTE: * SWL Tension Concrete values are provided for use with the tables on pages 17
and 18 for tension load reduction due to edge distance conditions closer than 1.5 x the
insert length. Installed SWL is determined by the actual concrete capacity (edge conditions,
strength, etc.), but can never be greater than the mechanical rating of the anchor.
A
C
To Order:
Specify: (1) quantity, (2) product code, (3)
bolt diameter, (4) length, (5) finish.
Example:
400, B1 Coil Ties, 1-1/4" dia. x 8" long,
plain finish.
Mounting Washers
Most Dayton Superior 1/2", 3/4", 1", 1-1/4" or 1-1/2" diameter coil inserts are available with
an 11 gauge mounting washer welded to the upper ends of the strut wires. The 1/2", 3/4"
and 1" diameter coil inserts use a 2" x 2" square washer, while the 1-1/4" and 1-1/2" inserts
use a 3" x 3" square washer.
The mounting washer allows an insert to be fastened to wood forms with ease. When
inserts are ordered with mounting washers, they are supplied with Ethafoam plugs to
keep concrete out of the coil. Removal of the Ethafoam plug clears the insert, allowing for
proper engagement of the lifting bolt.
11/12
Lifting/Handling
Inserts
and Accessories
B1 or B2 Coil Ties
Insert
Type
B1
B1
B1
B1
B1
B1
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
3/16"
diameter
nail holes,
2 places
Mounting Washer
81
Bolt
Diameter
1/2"
1/2"
3/4"
3/4"
1"
1"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
Safe Working
Load
1,800lbs.
2,700lbs.
2,700lbs.
3,600lbs.
7,200lbs.
15,000lbs.
10,800lbs.
15,000lbs.
15,000lbs.
15,000lbs.
Sizes
3" x 4" x 1/4"
4" x 5" x 1/4"
4" x 5" x 3/8"
5" x 5" x 3/8"
5" x 5" 1/2"
7" x 7" x 3/4"
5" x 5" x 5/8"
7" x 7" x 3/4"
5" x 5" x 3/4"
7" x 7" x 3/4"
To Order:
Specify: (1) quantity, (2) type, (3) diameter of bolt
to be used, (4) finish.
Example:
200, B11 Heavy Flat Washers, 1" bolt dia., plain finish.
Lifting/Handling
Inserts
and Accessories
Used with B13 or B25 Coil Nuts for making special coil bolts.
B12 requires two B13 or one B25 Coil Nut to develop safe working loads.
Example:
Coil Rod
To Order:
Diameter
Tension
Shear
Tension
Shear
1/2"
3,600 lbs.
2,400 lbs.
2,700 lbs.
1,800 lbs.
3/4"
7,200 lbs.
4,800 lbs.
1"
15,000 lbs.
10,000 lbs.
1-1/4"
22,500 lbs.
15,000 lbs.
1-1/2"
27,000 lbs.
18,000 lbs.
Type
Diameter
Approx.
Height
B13
1/2"
7/16"
2,400 lbs.
3,600 lbs.
B25
1/2"
1-3/16"
3,600 lbs.
B13
3/4"
5/8"
3,600 lbs.
7,200 lbs.
B25
3/4"
1-3/16"
7,200 lbs.
B13
1"
1"
9,600 lbs.
15,000 lbs.
B25
1"
2"
15,000 lbs.
To Order:
B13
1-1/4"
1-1/4"
14,400 lbs.
22,500 lbs.
B13
1-1/2"
1-1/2"
19,000 lbs.
27,000 lbs.
Example:
82
Height
Height
B25 Heavy
Coil Nut
11/12
Insert Setback
Min. Coil
Penetration
Hardware
Height
Coil
Hex Head
Minimum Thread
Length
Bolt
Length
Insert Setback.
To Order:
Example:
200, B14 Coil Bolts, 1" dia. X 12" long, forged head.
1/2" Diameter
3/4" Diameter
1" Diameter
1-1/4" Diameter
1-1/2" Diameter
Tension
Tension
Tension
Tension
Tension
Shear
Shear
Shear
Shear
Lifting/Handling
Inserts
and Accessories
Shear
3,600 lbs. 2,400 lbs. 8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.
Minimum Coil
Penetration 2"
Minimum Coil
Penetration 2-1/4"
Minimum Coil
Penetration 2-1/2"
Minimum Coil
Penetration 2-1/2"
Minimum Coil
Penetration 3"
Bolt
Length
Minimum
Thread
Length
Bolt
Length
Minimum
Thread
Length
Bolt
Length
Minimum
Thread
Length
Bolt
Length
Minimum
Thread
Length
Bolt
Length
Minimum
Thread
Length
3"
2-1/4"
3"
2-3/4"
3"
2-3/4"
3"
2-3/4"
4"
3-1/4"
4"
3-3/4"
4"
3-3/4"
4"
3-3/4"
4"
3-3/4"
5"
4-1/4"
5"
4-3/4"
5"
4-3/4"
5"
4-3/4"
5"
4-3/4"
6"
5"
6"
5-3/4"
6"
5-3/4"
6"
5-3/4"
6"
5-3/4"
Over 6"
5"
Over 6"
5-3/4"
Over 6"
5-3/4"
Over 6"
5-3/4"
Over 6"
5-3/4"
11/12
83
Although simple in design and fabrication, the B16 Straight Coil Loop Insert is highly
efficient for lifting and handling precast concrete elements. Standard inserts are
shown in the chart. Special inserts for use with larger diameter coil bolts, or with
loops having longer lengths and of heavier wire can be furnished, if required, on
special order.
B16 Straight Coil Loop Insert Selection Chart
Insert
Bolt
Diameter Length
1/2"
3/4"
1/2"
3/4"
or 1"
3"
4"
6"
Minimum
Edge
Distance
2"
3"
5"
10"
2"
3"
5"
8"
2"
3"
5"
12"
Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
5"
810 lbs.
200 lbs.
5"
1,310 lbs.
325 lbs.
10"
1,950 lbs.
1,050 lbs.
10"
1,950 lbs.
1,350 lbs.
5"
1,190 lbs.
200 lbs.
5"
1,910 lbs.
325 lbs.
10"
1,950 lbs.
1,050 lbs.
10"
1,950 lbs.
2,250 lbs.
7"
1,420 lbs.
225 lbs.
7"
2,240 lbs.
425 lbs.
7"
3,600 lbs.
775 lbs.
12"
3,600 lbs.
3,600 lbs.
3"
0.223"
4"
0.223"
To Order:
Specify: (1) quantity, (2) name,
(3) bolt diameter, (4) length,
(5) finish.
Example:
6"
0.306"
Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Lifting/Handling
Inserts
and Accessories
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for
lifting/handling of precast panels.
B
The design of the B17 insert leaves an open space between the two loops, allowing
the B17 insert to straddle reinforcing steel or prestressing strands.
Standard sizes are shown in the chart and other sizes are
available on special order.
Minimum spacing between inserts is twice the minimum corner
distance.
The safe working load of the B17 Double Flared Coil Loop Insert is greatly increased
over that of a B18 Single Flared Coil Loop. This increase in capacity is achieved by
welding a second loop to the same coil. By adding the additional loop, it doubles
the cross-sectional area of steel embedded in the concrete and at the same time,
increases the area of the shear cone.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) length, (5) finish.
Example:
400, B17 Double Flared Coil Loop Inserts, 1-1/4"
dia. x 12-3/8" long, plain finish.
Minimum
Edge
Distance
5"
9"
12"
18"
5"
9"
12"
18"
Minimum
Corner
Distance
15"
15"
18"
27"
15"
15"
18"
27"
Safe
Working Load
Tension
4,910 lbs.
9,500 lbs.
9,500 lbs.
9,500 lbs.
4,950 lbs.
9,810 lbs.
11,150 lbs.
13,500 lbs.
Safe
C
D
A
B
Working Load
Shear
2,780 lbs.
6,720 lbs.
12-3/8" 0.375" 5-9/16" 5-9/16"
9,500 lbs.
9,500 lbs.
2,940 lbs.
7,120 lbs.
12-1/2" 0.440" 5-3/4" 5-3/4"
10,960 lbs.
13,500 lbs.
Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
84
11/12
B18 inserts are available with an optional B3 Screw-on Coil for use with the
B30 Screw-on Plastic Cone which acts to set the insert back from the face of
the concrete.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) length,
(5) finish.
Make certain
setting bolt is of
sufficient length to
form a cavity for
lifting bolt.
Example:
Minimum
Edge Distance
or Greater
200, B18 Single Flared Coil Loop Inserts, 1" dia. x 12" long,
plain finish.
Shear Direction
Bolt
Diameter
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1-1/4"
1-1/2"
Insert
Height
Minimum
Edge Distance
Minimum Corner
Distance
SafeWorking Load
Shear
4"
5"
10"
2,250lbs.
1,510lbs.
4"
8"
10"
2,250lbs.
2,250lbs.
6"
5"
10"
2,930lbs.
1,770lbs.
6"
12"
12"
3,750lbs.
3,750lbs.
9"
5"
10"
3,750lbs.
1,770lbs.
9"
12"
12"
3,750lbs.
3,750lbs.
12"
5"
10"
3,750lbs.
1,770lbs.
12"
12"
12"
3,750lbs.
3,750lbs.
9"
5"
10"
4,500lbs.
1,960lbs.
9"
15"
15"
4,500lbs.
4,500lbs.
12"
5"
10"
4,500lbs.
1,960lbs.
12"
12"
12"
4,500lbs.
4,500lbs.
6"
5"
10"
2,920lbs.
1,960lbs.
6"
12"
12"
4,500lbs.
4,500lbs.
9"
5"
10"
4,500lbs.
1,960lbs.
9"
12"
12"
4,500lbs.
4,500lbs.
12"
5"
10"
4,500lbs.
1,960lbs.
12"
12"
12"
4,500lbs.
4,500lbs.
12"
5"
12"
5,970lbs.
2, 130lbs.
12"
14"
14"
7,500lbs.
7,500lbs.
12"
7"
10"
7,500lbs.
3,530lbs.
12"
7"
14"
7,500lbs.
3,530lbs.
12"
7"
10"
7,500lbs.
3,530lbs.
12"
14"
14"
7,500lbs.
7,500lbs.
4"
1-3/16"
3"
0.223"
6"
1-5/8"
5-1/2"
0.306"
9"
1-5/8"
5-1/2"
0.306"
12"
1-5/8"
5-1/2"
0.306"
9"
1-3/4"
5-5/8"
0.375"
12"
1-3/4"
5-5/8"
0.375"
6"
1-7/8"
5-5/8"
0.375"
9"
1-7/8"
5-5/8"
0.375"
12"
1-7/8"
5-5/8"
0.375"
12"
2-1/4"
5-7/8"
0.440"
12"
2-1/2"
5-7/8"
0.440"
12"
2-3/4"
5-7/8"
0.440"
Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.
11/12
85
Lifting/Handling
Inserts
and Accessories
DS_B33
The safe working load of the B33 Double Flared Coil Loop Insert is identical to
that of the B17 Double Flared Coil Loop. However, its crisscross design will not
allow the insert to straddle reinforcing steel or prestressing strands.
D
C
Standard sizes are shown in the chart and other sizes are available on special
order. Minimum spacing between inserts is twice the minimum corner distance.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) length,
(5) finish.
Example:
400, B33 Double Flared Coil Loop Inserts, 1-1/4" dia. x 12-3/8"
long, plain finish.
B33 Double Flared Coil Loop Insert Selection Chart
Bolt
Diameter
1"
1-1/4" or
1-1/2"
Lifting/Handling
Inserts
and Accessories
1"
1-1/4" or
1-1/2"
Minimum
Edge
Distance
5"
9"
12"
18"
5"
9"
12"
22"
Minimum
Safe
Safe
A
B
C
D
Corner
Working Load Working Load
Distance
Tension
Shear
15"
4,910 lbs.
2,780 lbs.
15"
9,500 lbs.
6,720 lbs.
12-3/8" 0.375" 5-9/16" 5-9/16"
18"
9,500 lbs.
9,500 lbs.
18"
9,500 lbs.
9,500 lbs.
15"
4,870 lbs.
2,940 lbs.
15"
9,650 lbs.
7,100 lbs.
12-1/2" 0.440" 5-3/4" 5-3/4"
18"
10,960 lbs.
10,940 lbs.
22"
13,500 lbs.
13,500 lbs.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
3/4" Coil
The Dayton Superior F47 Double Flared Loop Insert has been designed for use in
3-1/4" or thicker precast concrete elements. This insert is available for use with
3/4" diameter coil bolts only.
2-3/4"
Minimum
Height
To Order:
Specify: (1) quantity, (2) name, (3) finish.
.223" Diameter
Example:
200, F47 Double Flared Loop Inserts, plain finish.
4-5/8"
3/4" x 2-3/4"
2,750 lbs.
Concrete
Strength
Minimum
Edge
Distance
2,500 psi
6"
8"
3-1/
86
11/12
DS_F48F49F49A
The Dayton Superior F48 Eye Nut is cast from ductile iron that meets ASTM Standard A-536
Grade 80-55-06. The eye nut is cast with coil threads and is intended to be used with B12 Coil
Rod that has been cut to the proper length. The eye nut eliminates the need to inventory several
different lengths of eye bolts.
To make permanent length eye bolts, it is possible to weld lengths of coil rod to the casting.
Since improper welding techniques can result in reduced safe working loads, Dayton Superior
recommends that you contact your local welding supply house for proper welding instructions
and techniques.
The F49 Eye Bolt is an F48 Eye Nut supplied with a specified length of coil rod that has been
welded in place. In order to develop the F49 eye bolts rated load, the shoulder must be
tightened securely against the face of the concrete.
The F48 Eye Nut and F49 Eye Bolt are intended for straight tensile loading only; pulling or lifting
at an angle drastically reduces the safe working load and is not recommended.
F48 Eye Nut and F-49 Eye Bolt Selection Chart
Safe Working
Load
Tension
Coil Rod
Diameter
2,700 lbs.
1/2"
3-1/4"
1"
1"
3/4"
2"
3,600 lbs.
3/4"
3-1/2"
1-1/4"
1"
3/4"
2"
7,200 lbs.
1"
5"
1-1/4"
1-3/4"
1"
3"
10,800 lbs.
1-1/4"
6-1/4"
1-1/2"
2-1/4"
1-1/4"
4"
Weld
Area
Length
Dimensions
Coil
Thread
Example:
Example:
Lifting/Handling
Inserts
and Accessories
The F49A Eye Bolt is a forged, carbon steel, one piece, shoulder pattern eye bolt. It is available with 3/4"
or 1" diameter coil threads and stocked in 3-1/2" and 6" lengths. Other lengths are available special order.
In order to develop the F49A Eye Bolts rated load, the shoulder must be tightened firmly against the
face of the concrete. The eye bolt is intended for straight tensile loading only; pulling or lifting at an
angle drastically reduces the safe working load and is not recommended. The F49A Eye Bolt meets
material requirements of ASTM Standard A-489.
Length
Tension
Safe Working
Load
3/4"
3,600 lbs.
2-7/8"
1-1/2"
3" or 6
1"
6,400 lbs.
3-1/2"
1-3/4"
3"
Length
11/12
87
DS_P21
The P21 Dayton Superior Wire Rope Loop provides a fast method for handling precast items. Designed
to work with 3/4" and 1" diameter coil inserts under straight tension loads only. Do not use under shear
loading conditions, instead, use a swivel lift plate and coil bolt. With proper care, the wire rope loop can be
reused. Visual evidence of any deterioration of the wire rope is a safety feature of this product.
A
Diameter x
Type of Thread
Safe Working
Load Tension
Loop Dimensions
A
1/2" Coil
2,000lbs.
6"
2"
1 - 1/4"
3/4" Coil
5,200lbs.
8 - 3/4"
2 - 1/2"
1 - 3/4"
1" Coil
8,000lbs.
12"
3"
2 - 1/4"
Diameter
To Order:
Specify: (1) quantity, (2) name, (3) diameter.
Example:
100, P21 Wire Rope Loop, 3/4" dia.coil.
The Dayton Superior F53 Thin Slab Coil Insert is designed for lifting thin
precast concrete panels from the casting bed and for handling the panels
until they are set into their final position. Inserts should be set back 1/2"
from the surface of the concrete, maintaining at least 3/4" of concrete
below the insert. Minimum spacing between inserts is twice the minimum
corner distance. Available in insert heights up to 4".
A
C
A
15
A
Insert
Height
Minimum
Edge
Distance
Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
3/4"
3"
8"
12"
2,340 lbs.
2,340 lbs.
3"
7-1/8"
0.306"
1"
4"
10"
15"
3,520 lbs.
3,460 lbs.
4"
9-3/8"
0.306"
1-1/4"
4"
10"
15"
3,520 lbs.
3,460 lbs.
4"
9-5/8"
0.306"
1-1/2"
4"
10"
15"
3,520 lbs.
3,460 lbs.
4"
9-7/8"
0.306"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) height, (5) finish.
Example:
200, F53 Thin Slab Coil Inserts, 1" dia. x 4" height,
plain finish.
88
11/12
Expanded Coil Inserts are fabricated in two, four or six strut versions, as required. A
standard coil is welded at one end of the strut wires and on the opposite end, an
expanded pitch coil is welded. The expanded pitch coil welded to the more deeply
embedded end of the insert, serves to distribute the applied loads over a larger
volume of concrete.
DS_F56F58F60
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) finish.
Example:
200, F60 Expanded Coil Inserts, 1-1/2" diameter,
plain finish.
Insert
Type
Bolt
Diameter
Insert
Length
F56
Coil
3/4"
4-1/2"
F56
Coil
1"
5-1/2"
F58
Coil
1-1/4"
7-1/2"
F60
Coil
1-1/2"
9-1/2"
Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
6"
1,800 lbs.
680 lbs.
8"
2,220 lbs.
1,380 lbs.
12"
4,250 lbs.
2,760 lbs.
20"
4,250 lbs.
4,250 lbs.
7"
2,000 lbs.
740 lbs.
9"
2,560 lbs.
1,500 lbs.
12"
5,300 lbs.
3,250 lbs.
24"
6,250 lbs.
6,250 lbs.
10"
2,480 lbs.
1,270 lbs.
12"
3,600 lbs.
2,730 lbs.
15"
5,700 lbs.
4,790 lbs.
26"
10,480 lbs.
10,590 lbs.
12"
2,820 lbs.
1,500 lbs.
15"
3,880 lbs.
3,230 lbs.
15"
6,680 lbs.
6,260 lbs.
30"
14,580 lbs.
16,430 lbs.
4-1/2"
0.375"
1-1/2"
5-1/2"
0.440"
2-1/2"
7-1/2"
0.440"
2-3/4"
9-1/2"
0.440"
3-5/8"
Lifting/Handling
Inserts
and Accessories
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Load is based on a 1/2" setback from face of concrete.
11/12
89
C
B
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) height, (5)
finish.
Example:
200, F63 Flared Thin Slab Coil Inserts, 1" dia. x 4-1/2" plain finish.
F63 Flared Thin Slab Coil Insert Selection Chart
Bolt
Insert
Diameter Height
Minimum
Edge
Distance
Minimum
Safe
Safe
Corner Working Load Working Load
Distance
Tension
Shear
Lifting/Handling
Inserts
and Accessories
1/2"
1-3/4"
6"
6"
1,520 lbs.
1,090 lbs.
1-3/4"
4-1/8"
0.223"
3/4"
2-5/16"
8"
8"
2,170 lbs.
1,640 lbs.
2-5/16"
4-7/8"
0.306"
3/4"
3-1/2"
9"
9"
3,570 lbs.
2,600 lbs.
3-1/2"
4-7/8"
0.306"
1"
2-5/16"
8"
8"
2,460 lbs.
1,970 lbs.
2-5/16"
5-1/4"
0.306"
1"
4-1/2"
12"
12"
5,280 lbs.
4,000 lbs.
4-1/2"
5-1/4"
0.306"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.
DS_F65
The Dayton Superior F65 Type L Coil Insert is designed for use in lifting and handling
lightweight precast concrete elements. Inserts should be set back 1/2" from the
surface of the concrete. Minimum spacing between inserts is twice the minimum
corner distance.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.
Example:
200, F65, Type L Coil Inserts, 1/2" diameter, plain finish.
A
Insert
Length
1/2"
4"
3/4"
4"
Minimum
Edge
Distance
2-1/2"
5"
8"
2-1/2"
5"
8"
Minimum
Corner
Distance
10"
10"
12"
10"
10"
12"
Safe
Working Load
Tension
1,150 lbs.
2,250 lbs.
2,250 lbs.
1,140 lbs.
2,630 lbs.
3,520 lbs.
Safe
Working Load
Shear
530 lbs.
1,230 lbs.
1,980 lbs.
600 lbs.
1,400 lbs.
2,250 lbs.
4"
2-3/8"
0.223"
4"
3-3/8"
0.306"
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.
Note: Chart based on Face Lift usage of inserts.
90
11/12
Dayton Superior T1 Single Pickup Inserts are available with plastic or stainless
steel tips and with or without T21 Insert Locator Plugs installed. T1 inserts are
designed for use with T12 or T26 Swivel Lifting Plates. Do not use T1 inserts
as an edge or end pick-up insert.
Height of insert is 3/8" less than the panels structural thickness. Standard
panel thickness is shown in the chart and other panel thickness is available on
special order.
Minimum spacing between inserts is twice the minimum corner distance.
T1 Single Pick-up Insert Selection Chart
3/4"
1"
1-1/4"
1-1/2"
4"
5"
6"
7"
8"
4"
5"
6"
7"
8"
4"
5"
6"
7"
8"
4"
5"
6"
7"
8"
Minimum
Edge
Distance
9"
11"
12"
14"
16"
10"
12"
13"
14"
16"
10"
12"
14"
15"
15"
12"
14"
14"
15"
16"
Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
9"
2,360 lbs.
2,360 lbs.
16"
3,540 lbs.
3,540 lbs.
18"
4,880 lbs.
4,880 lbs.
21"
6,350 lbs.
6,350 lbs.
24"
7,950 lbs.
7,950 lbs.
10"
2,450 lbs.
2,450 lbs.
12"
3,650 lbs.
3,650 lbs.
16"
5,000 lbs.
5,000 lbs.
21"
6,480 lbs.
6,480 lbs.
24"
8,080 lbs.
8,080 lbs.
10"
2,540 lbs.
2,540 lbs.
14"
3,750 lbs.
3,750 lbs.
15"
5,110 lbs.
5,110 lbs.
18"
6,610 lbs.
6,610 lbs.
24"
8,200 lbs.
8,200 lbs.
12"
2,640 lbs.
2,640 lbs.
14"
3,860 lbs.
3,860 lbs.
16"
5,230 lbs.
5,230 lbs.
21"
6,740 lbs.
6,740 lbs.
24"
8,200 lbs.
8,200 lbs.
To Order:
Specify: (1) quantity, (2) name, (3) diameter,
(4) panel structural thickness, (5) type of tips.
Example:
200, T1 Single Pickup Inserts, 3/4" dia., 5"
panel structural thickness, plastic tipped feet.
Lifting/Handling
Inserts
and Accessories
Panel
Bolt
Diameter Thickness
11/12
91
.375" Diameter
Loop for Tension
12"
12"
.375"
Diameter
Shear Bar
.375" Diameter
Shear Bar
5-3/4"
12"
5-1/2"
23"
11-1/2"
Lifting/Handling
Inserts
and Accessories
Insert
Type
Bolt
Diameter
Load
Condition
4"
Panel
5"
Panel
5-1/2"
Panel
6"
Panel
6-1/2"
Panel
7"
Panel
7-1/2"
Panel
8"
Panel
T3A
3/4"
Single
Tension
1,500 lbs.
Shear
1,250 lbs.
T3A
1"
Single
Tension
3,000 lbs. 3,300 lbs. 3,600 lbs. 3,900 lbs. 4,200 lbs. 4,500 lbs. 4,500 lbs.
Shear
1,350 lbs. 1,375 lbs. 1,400 lbs. 1,425 lbs. 1,450 lbs. 1,500 lbs. 1,550 lbs.
T3
3/4"
Double
Tension
2,500 lbs.
Shear
1,500 lbs.
1"
Double
Tension
4,000 lbs. 4,400 lbs. 4,800 lbs. 5,200 lbs. 5,600 lbs. 6,000 lbs. 6,000 lbs.
Shear
2,100 lbs. 2,250 lbs. 2,400 lbs. 2,550 lbs. 2,700 lbs. 2,850 lbs. 3,000 lbs.
T3
Safe working load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
To Order:
Specify: (1) quantity, (2) name, (3) diameter.
Example:
200, T3 End Pickup Inserts, 1" diameter.
92
11/12
Used with standard coil threaded inserts to provide void for B14 coil bolts.
Standard steel sizes are 1/2", 3/4", 1", 1-1/4" and 1-1/2" diameter x 4"
long. Other lengths available on request.
Length
Length
T7S
T7ST
To Order:
Specify: (1) quantity, (2) name, (3) diameter.
Example:
200, T7S Slotted Setting Studs, 1" diameter.
DS_P25
The Dayton Superior Plastic Setting Bolt is used to attach 1/2", 3/4" and 1" diameter coil inserts to wood
frames. The head of the setting bolt has nail holes allowing easy attachment of the bolt. The plastic setting
bolt positions the insert 3/4" from concrete surface.
Bolt
Diameter
Length
Thread
100210
1/2"
2"
100220
3/4"
3-1/4"
100230
1"
4-3/4"
To Order:
Specify: (1) quantity, (2) name, (3) diameter.
Lifting/Handling
Inserts
and Accessories
Product Code
Length
Thread
Example:
200, P25 Plastic Setting Bolt, 1" diameter.
May be use for face lifting inserts and edge lifting inserts when panel thickness
exceeds 6".
12"
D
T8 Lifting Angle
Bolt
Diameter
Clevis
Hole
1"
18"
12"
6"
4"
5/8"
1-3/4" dia.
1-1/4"
1-1/2"
21"
15"
6"
6"
3/4"
1-1/2" dia.
11/12
To Order:
Specify: (1) quantity, (2) name, (3) bolt
diameter.
Example:
200, T8 Lifting Angles, 1-1/4" bolt diameter.
93
0.440"
B
B
12"
12"
24"
6"
1/2"
0.440"
6"
A
1/2"
0.440"
0.440"
To Order:
Specify: (1) quantity, (2) name, (3) length, (4) struts.
Lifting/Handling
Inserts
and Accessories
Example:
200, T11 Single End Pickup Inserts, 1" dia. x 9" height, 4 struts.
Insert
Type
Bolt
Diameter
No. of
Struts
Wires
Insert
Length
Minimum
Corner Distance
Safe Working
Load Tension
Safe
Working
Load Shear
Minimum
Panel
Thickness
T10
1"
9"
11"
3,660lbs
1,300lbs
9"
9"
3-1/16"
T10
1-1/4"
10"
9"
3,870lbs
1,520lbs
10"
10"
3-5/16"
T10
1"
9"
11"
3,660lbs
1,680lbs
9"
9"
3-1/16"
T10
1"
12"
14"
5,540lbs
2,740lbs
12"
12"
3-1/16"
T10
1"
15"
18"
7890lbs
3,950lbs
15"
15"
3-1/16"
T11
1"
9"
15"
7,250lbs
2,450lbs
9"
9"
3-1/16""
T11
1-1/4"
10"
15"
6,190lbs
2,740lbs
10"
10"
3-5/16"
T11
1"
9"
15"
8,730lbs
3,180lbs
9"
9"
3-1/16"
T11
1"
12"
19"
11,640lbs
4,570lbs
12"
12"
3-1/16"
T11
1"
15"
19"
12,390lbs
6,070lbs
15"
15"
3-1/16"
Safe working load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe working load based on 0 setback from face of concrete.
94
11/12
Cut Washers or
1/2" Thick Wood Washer
P
L/2
15"
Minimum
Edge
Distance
L/2
Cen
Lin ter
Stru e of
Thic ctural
knes
s
Coil Bolt
Casting Surface
L
Note: Shear Bar must be
on top of coils for T3 or
T3A inserts.
Always check to make certain that you have the proper clearance under the coil to prevent the lifting bolt from bottoming
out against the concrete. You must be able to tighten the bolt securely to prevent the lifting hardware from slipping and
applying unexpected loads to the insert.
Minimum Coil Penetration
and Void
Minimum Coil
Penetration
Insert Setback
Insert Setback
Form Lumber
T27 Lifting
Plate
Required
Bolt Length
Void
Plate Thickness
Lifting Bolt
Setting Bolt
Note: Face insert lifting bolt lengths are calculated in Setting Bolt for Edge Inserts
a similar manner to that shown above.
Form Lumber
1-1/2"
Safety Notes
Insert Setback
11/12
Minimum Void
1/2"
2-1/2"
1/2"
5"
1"
1/2"
2-1/2"
4"
95
Lifting/Handling
Inserts
and Accessories
T12
Swivel
Lifting
Plate
5"
Safety Notes
1-3/8"
Type
T12
Bolt
Diameter
Safe Working
Load
Bearing Plate
Size
3/4"
7,200lbs.
1"
10,000lbs.
1/2 x 2-1/2"
x 5"
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
10, T12 Swivel Lifting Plates, 1" bolt diameter.
Lifting/Handling
Inserts
and Accessories
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
3/4" diameter
only
Designed for use with 1", 1-1/4" and 1-1/2" diameter coil bolts.
Round bearing plate provides maximum safety when used with any coil bolt lifting system.
Bolt
Diameter
1"
1-1/4"
1-1/2"
2-11/16"
2-3/4"
2-3/4"
5"
7"
7"
Safe Working
Load
9,000
13,500
13,500
96
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
10, T26 Double Swivel Lifting Plate, 1-1/4" bolt diameter.
11/12
1" Thick
5 1/2"
For use on panels up to 6" thick; on panels thicker than 6", use T8.
12"
18"
4"
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
10, T27 Edge Lifting Plate, 1" bolt diameter.
Prior to lifting any precast element, apply an initial cable tension making certain that the bail or clevis attachment plate
is aligned in the direction of the load at all times. Crane line loads must not be allowed to apply a sideward load to the
bail or clevis attachment plate, as this condition is dangerous and could lead to a premature failure.
Load
Clevis
Attachment
Plate
Lifting/Handling
Inserts
and Accessories
Clevis
Attachment
Plate
Right
Wrong
Load
Bail
Bail
Right
Wrong
11/12
97
98
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
The Dayton Superior F5 Threaded Inserts have National Course (NC) threads and are recommended
for use under permanent loading conditions. This insert has been approved by the Board of
Standards and Appeals for use in New York City under Calendar No. 447-60SM.
The F5 insert is cast from ductile iron that meets ASTM A-395, Grade 60-40-18.
F5
Threaded Insert
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
200, F5 Threaded Inserts, 3/4" bolt diameter.
Tension Safe
Bolt
Working Load Engagement
1/2" 13
1,500 lbs.
15/16"
1-5/8"
2-1/2"
1-5/8"
5/8" 11
2,000 lbs.
3/4"
1-5/8"
3"
1-5/8"
3/4" 10
2,500 lbs.
7/8"
1-13/16"
3"
1-7/8"
7/8" 9
3,000 lbs.
1-5/16"
2-1/2"
3-3/8"
2-5/8"
1" 8
3,000 lbs.
1-5/16"
2-1/2"
3-3/8"
2-5/8"
Safe Working Load provides a factor of safety of approximately 3 to 1 when the insert is
properly embedded in 3,000 psi normal weight concrete.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Maximum
Bolt
Engagement
1/8"
Example:
Structural
Connectors
Safe
Maximum Bolt
Working Load
Engagement
Shear
5"
650 lbs.
650 lbs.
5"
5"
2,000 lbs.
1,260 lbs.
10"
15"
2,000 lbs.
2,000 lbs.
5"
5"
2,000 lbs.
1,280 lbs.
7"
10"
2,000 lbs.
2,000 lbs.
5"
7"
2,200 lbs.
1,990 lbs.
8"
8"
2,200 lbs.
2,200 lbs.
5"
7"
2,200 lbs.
1,990 lbs.
8"
8"
2,200 lbs.
2,200 lbs.
8"
8"
5,300 lbs.
4,060 lbs.
10"
15"
5,300 lbs.
5,300 lbs.
8"
8"
5,300 lbs.
4,060 lbs.
10"
15"
5,300 lbs.
5,300 lbs.
5"
3/4"
2-3/4"
0.243"
3/4"
2-3/4"
0.243"
1"
2-3/4"
0.243"
1-1/8"
3-1/2"
0.258"
1-1/8"
3-1/2"
0.258"
1-1/8"
6"
0.375"
1-1/8"
6"
0.375"
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
11/12
99
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
Maximum
Bolt
Engagement
Stainless Steel
Identification
Knurl
Bolt Diameter
and Threads
per Inch
Maximum
Bolt
Engagement
1/4" 20 NC
3/4"
1-1/4"
9/16"
3/8" 16 NC
3/4"
1-1/4"
9/16"
1/2" 13 NC
1"
1-3/8"
11/16"
5/8" 11 NC
To Order:
1-1/8"
1-5/8"
7/8"
3/4" 10 NC
1-1/8"
1-5/8"
1"
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.
7/8" 9 NC
1-1/8"
1-5/8"
1-1/4"
All of the ferrules and ferrule inserts listed in this handbook are
tapped with National Course (NC) threads. Dayton Superior can
furnish, on special order, ferrules that are tapped with metric threads.
Note: All ferrules are made with a knock-out area in the closed
bottom. When knocked out, the hole will accept a #8-32 self
tapping screw that is used to attach ferrule inserts to the form face.
Example:
2000 pcs., F43 Plain Ferrules, 3/8" bolt diameter, type 304 SS.
1" 8 NC
1-1/8"
1-5/8"
1-3/8"
1-1/4" 7 NC
1-3/4"
2-1/2"
1-5/8"
1-1/2" 6 NC
2-1/4"
3"
1-7/8"
Note: As the Ferrule SWL's listed are based on compression loading conditions, do not attempt to use these safe working
loads with regular ferrule inserts.
Nominal Bolt
Diameter and
Threads per Inch
Minimum
Bolt
Engagement
Maximum
Safe
working Load
3/4" - 10
1/4" 7 mm
5,500lbs. 24.4 kN
3/4" - 10
3/8" 10 mm
7,200lbs. 32.0 kN
3/4" - 10
1/2" 13 mm
8,700lbs. 38.6 kN
3/4" - 10
3/4" 19 mm
10,300lbs. 45.8 kN
100
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
0.262"
4"
0.262"
Bolt Diameter
and Threads
Per Inch
Safe
Working Load
Tension
Maximum
Bolt
Engagement
1/4" 20 NC
450 lbs.
3/4"
1-1/4"
9/16"
3/8" 16 NC
450 lbs.
3/4"
1-1/4"
11/16"
1/2" 13 NC
900 lbs.
1"
1-3/8"
13/16"
5/8" 11 NC
1,000 lbs.
1-1/8"
1-5/8"
1-1/16"
3/4" 10 NC
1,600 lbs.
1-1/8"
1-5/8"
1-1/16"
7/8" 9 NC
1,600 lbs.
1-1/8"
1-5/8"
1-1/16"
1" 8 NC
1,600 lbs.
1-1/8"
1-5/8"
1-1/16"
Dimensions
A
To Order:
4"
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.
Example:
200, F44 Thin Slab Ferrule Inserts, 1/2" bolt diameter, plain finish.
Structural
Connectors
F45 Cap
Plug
To Order:
Specify: (1) quantity, (2) name, (3) size.
Example:
200, F45 Cap Plugs, 1/2" diameter.
11/12
101
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
Length
The Dayton Superior F50 Rocket Kohler Ferrule Insert is a two-strut ferrule insert with
an extended length ferrule and integral washer face. The F50 insert is available in
diameters from 1/4" through 1-1/4" and is well suited for structural connections or
supporting hung ceilings, equipment, piping, etc.
A
B
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.
Example:
200, F50 Rocket/Kohler Ferrule Insert, 1/2" bolt diameter,
plain finish.
F50 Rocket/Kohler
Ferrule Insert
F50 Rocket/Kohler Ferrule Insert Selection Chart
Bolt Diameter
Safe
Safe
Insert Minimum Minimum
and Threads
Corner Working Load Working Load
Length Edge
Per Inch
Distance Distance
Tension
Shear
Maximum
Bolt
Engagement
1/4" 20 NC
1-3/4"
4"
6"
750 lbs.
750 lbs.
1-3/4"
0.223"
1-1/4"
3/8" 16 NC
1-3/4"
4"
6"
1,050 lbs.
1,350 lbs.
1-3/4"
0.223"
1-1/4"
1/2" 13 NC
2-1/4"
6"
9"
1,575 lbs.
1,075 lbs.
2-1/4"
0.223"
1-3/4"
5/8" 11 NC
3-3/8"
6"
11"
3,000 lbs.
3,000 lbs.
3-3/8"
0.306"
2-3/4"
3/4" 10 NC
3-3/8"
6"
11"
3,000 lbs.
3,000 lbs.
3-3/8"
0.306"
2-3/4"
7/8" 9 NC
3-3/4"
7"
12"
3,800 lbs.
3,800 lbs.
3-3/4"
0.375"
3-1/8"
1" 8 NC
3-3/4"
7"
12"
3,800 lbs.
3,800 lbs.
3-3/4"
0.375"
3-1/8"
1-1/8" 7 NC
4-1/4"
8"
14"
4,350 lbs.
4,350 lbs.
4-1/4"
0.375"
3-5/8"
1-1/4" 7 NC
4-1/4"
8"
14"
4,350 lbs.
4,350 lbs.
4-1/4"
0.375"
3-5/8"
Structural
Connectors
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
1/8"
A
D
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) insert height,
(5) finish.
15
B
Example:
B
C
200, F52 Thin Slab Ferrule Insert, 1" bolt diameter, 5-1/2" height,
plain finish.
Minimum
Corner
Distance
Safe
Working
Load
Tension
Safe
Working
Load
Shear
3-1/8"
8"
12"
3,680 lbs.
3,200 lbs.
3-1/8"
4-1/8"
12"
18"
5,300 lbs.
5,300 lbs.
4-1/8"
Bolt Diameter
and Threads
per Inch
Insert
Length
3/4" 10 NC
1" 8 NC
Maximum
Bolt
Engagement
3"
7"
0.306"
1-1/8"
4"
9-3/8"
0.306"
1-1/8"
Safe Working Loads provide a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
102
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
The Dayton Superior F54 Ductile Embed Insert is a one-piece, integrally hot forged
unit fabricated out of smooth, round steel meeting ASTM A-29 Hot Rolled Grade 1045
requirements.
Insert top has a round washer face with four nail holes. The user can nail or bolt the insert
to side forms or wet set in face of panel as required. The bottom end has a forged, washerface hex foot to resist pullout from the concrete.
Use as a cast-in-place insert or in a core and grout insert application. Several inserts can be
laced and/or templated together to provide preset anchorage patterns for closely-spaced
multiple insert requirements.
Length
Shaft
Dia.
Longer insert lengths are available when required. Minimum spacing between the inserts,
shown in the chart, is twice the minimum corner distance.
Available plain, electro-galvanized, hot-dipped galvanized or epoxy coated as required.
F54 Ductile Embed Insert
Nail
Running Nut
Form
Setting Bolt
To Order:
Specify: (1) quantity, (2) name, (3) shaft diameter, (4) overall length.
Example:
Structural
Connectors
3/4"
7-1/2"
3/4" 10 NC
7/8"
9"
7/8" 9 NC
1"
10-1/2"
1" 8 NC
1-1/8"
12"
1-1/4" 7 NC
1-3/8"
15"
Safe
Working Load
Tension
Safe
Minimum Minimum Flange
Maximum Bolt
Working Load
Edge
Corner Diameter
Engagement
Shear
Distance Distance
A
6,700 lbs.
4,310 lbs.
7-1/2"
15"
9,030 lbs.
5,420 lbs.
10"
18"
8,800 lbs.
5,890 lbs.
9"
18"
13,360 lbs.
8,020 lbs.
14"
20"
11,150 lbs.
8,050 lbs.
10-1/2"
18"
18,350 lbs.
11,090 lbs.
16"
24"
13,790 lbs.
10,160 lbs.
12"
24"
22,980 lbs.
14,540 lbs.
18"
30"
19,960 lbs.
15,570 lbs.
15"
30"
33,150 lbs.
20,340 lbs.
24"
36"
2"
15/16"
2-1/4"
1-1/8"
2-3/8"
1-5/16"
2-1/2"
1-1/2"
3-1/4"
1-7/8"
Safe Working Loads provide a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from the face of concrete.
Minimum spacing between inserts is twice the corner distance.
Note: Bolt diameter is 1/8" less shaft diameter all products.
11/12
103
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
The Dayton Superior Expanded Coil Ferrule Inserts were developed as a more
effective means for increasing the inserts tensile capacity, without increasing
its depth of embedment. By increasing the width of the base, the volume of
the resisting shear cone is significantly increased. The expanded pitch coils
welded to the more deeply embedded end of the insert serve to distribute
the applied loads over a larger volume of concrete.
Bolt
Diameter
Insert
and Threads Length
per Inch
F57
3/4" 10 NC
4-5/8"
F57
1" 8 NC
5-5/8"
F59
1-1/4" 7 NC
7-5/8"
F61
1-1/2" 6 NC
9-5/8"
Minimum
Edge
Distance
Minimum
Corner
Distance
Safe
Working
Load
Tension
Safe
Working
Load
Shear
6"
9"
4,650 lbs.
2,730 lbs.
14"
20"
5,890 lbs.
5,890 lbs.
8"
12"
6,990 lbs.
4,300 lbs.
16"
24"
8,100 lbs.
8,100 lbs.
10"
15"
9,920 lbs.
7,940 lbs.
18"
26"
13,310 lbs.
13,310 lbs.
12"
18"
13,180 lbs.
12,450 lbs.
22"
30"
18,680 lbs.
18,680 lbs.
Maximum
Bolt
Engagement
4-5/8"
2-1/8"
1-1/2"
0.375"
1-1/8"
5-5/8"
2-3/4"
2-1/4"
0.440"
1-1/8"
7-5/8"
3"
2-3/4"
0.440"
1-3/4"
9-5/8"
3-3/8"
3-5/8"
0.440"
2-1/4"
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on insert 1/2" setback from the face of concrete.
Structural
Connectors
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.
Example:
200, F61 Expanded Coil Ferrule Inserts, 1-1/2" dia., plain finish.
104
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) insert height,
(5) finish.
A
Example:
1, 000 pcs., F62 Flared Thin Slab Ferrule Insert, 1" bolt x 2-7/16"
high, plain finish.
Safe
Working
Load
Tension
Safe
Working
Load
Shear
6"
9"
2,120 lbs.
7"
10"
2,900 lbs.
6"
9"
9"
14"
6"
11"
Insert
Height
(A)
Minimum
Edge
Distance
1/2" 13 NC
1-7/8"
5/8" 11 NC
2-7/16"
3/4" 10 NC
2-7/16"
3/4" 10 NC
3-5/8"
1" 8 NC
2-7/16"
1" 8 NC
4-5/8"
Bolt Diameter
and Threads
per Inch
Maximum
Bolt
Engagement
2,120 lbs.
2"
4-3/4"
0.223"
1"
2,900 lbs.
2-"
4-3/4"
0.306"
1-1/8"
2,960 lbs.
2,960 lbs.
2"
4-7/8"
0.306"
1-1/8"
4,830 lbs.
4,830 lbs.
2"
4-7/8"
0.306"
1-1/8"
9"
3,080 lbs.
0.306"
1-1/8"
16"
6,780 lbs.
0.306"
1-1/8"
11/12
Structural
Connectors
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
Minimum spacing between inserts is twice the corner spacing.
105
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
1/8"
Structural
Connectors
Bolt Diameter
and Threads per
Inch
Insert
Height (A)
1/2" 13 NC
4-1/8"
1/2" 13 NC
6-1/8"
5/8" 11 NC
4-1/8"
5/8" 11 NC
6-1/8"
3/4" 10 NC
4-1/8"
3/4" 10 NC
6-1/8"
7/8" 9 NC
6-1/8"
1" 8 NC
6-1/8"
1" 8 NC
8-1/8"
Minimum
Edge Distance
Minimum
Corner
Distance
Safe Working
Load Tension
Safe Working
Load Shear
5"
10"
3,000lbs.
1,810lbs.
9"
15"
3,000lbs.
3,000lbs.
7"
12"
5,000lbs.
3,410lbs.
9"
12"
5,000lbs.
3,410lbs.
5"
10"
3,000lbs.
1,810lbs.
9"
12"
3,000lbs.
3,000lbs.
7"
12"
5,000lbs.
3,420lbs.
11"
15"
5,000lbs.
5,000lbs.
5"
10"
3,000lbs.
1,810lbs.
9"
12"
3,000lbs.
3,000lbs.
7"
12"
5,000lbs.
3,420lbs.
11"
15"
5,000lbs.
5,000lbs.
7"
12"
5,000lbs.
3,420lbs.
11"
15"
5,000lbs.
5,000lbs.
7"
12"
5,000lbs.
3,420lbs.
11"
12"
5,000lbs.
4,650lbs.
7"
12"
5,000lbs.
3,830lbs.
11"
15"
5,000lbs.
5,000lbs.
Maximum Bolt
Engagement
0.223"
1"
0.306"
1"
0.223"
1-1/8"
0.306"
1-1/8"
0.223"
1-1/8"
0.306"
1-1/8"
0.306"
1-1/8"
0.306"
1-1/8"
0.306"
1-1/8"
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from the face of the concrete.
Minimum spacing between inserts is twice the minimum corner distance.
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) insert length, (5) finish.
Example:
200, F64 Ferrule Loop Insert, 5/8" bolt diameter,
6-1/8" insert length, plain finish.
106
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
To Order:
Specify: (1) quantity, (2) name, (3) diameter.
Example:
200, F72 Threaded Setting Plugs, 3/4" diameter.
Nail or
#8-#32
Screw
Tapped
Internally with
#8-32 Thread
Dia.
3/8" 16 NC
3/8"
3/16"
1/2" 13 NC
3/8"
1/4"
5/8" 11 NC
1/2"
5/16"
3/4" 10 NC
5/8"
3/8"
1" 8 NC
1"
9/16"
Dimensions
To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.
Example:
F74 Threaded
Plastic Plug
Structural
Connectors
11/12
107
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
The Dayton Superior P87 Star Adapter Plug is available in all Star
Insert diameters. The P87 plug is a setting plug for installing the
insert into precast forms. Its use effectively seals the insert against
concrete seepage.
To Order:
Specify: (1) quantity, (2) name,
(3) diameter.
Example:
200, Star Adapter Plugs, 3/4"
diameter.
Before each use, coat the side of the plug as well as the threaded
portion with a form release or water resistant grease. This will allow
P87 Star
Adapter Plug
the plug to be easily removed from the concrete.
The plug may be ordered with a 1/8"diameter smooth hole, for use in nailing to wood forms or a #8-32 threaded
hole for attaching to steel forms.
P87 Star Insert Adapter Plug
Insert
Designation
Size
Product
Code
P25A
3/8"
9525003
3/4"
1/4"
P35A
1/2"
9535003
1"
1/4"
P45A
5/8"
9545004
1-1/8"
3/8"
P55A
3/4"
9555003
1-1/4"
3/8"
Nail
#8-32
Wood Form
Typical Installations
Steel Form
Structural
Connectors
Bolt
Diameter
and Threads
Per Inch
Safe Working
Load Tension
1/2" 13 NC
550 lbs.
2-3/8"
1"
T
Thread
Depth
2-5/32" 1-1/8"
Closed End
Closed End
To Order:
Specify: (1) quantity, (2) name.
Example:
Wood
Form
Stronghold
Nail
Typical Installations
Insert Length A
Length B
2=3/8"
7/8"
Width C
1-1/4"
Outer Diameter D
11/16"
Thread Length T
1-1/8"
Total Depth L
2=5/32"
Torque (ft.lbs.
19
108
1/2" - 13 NC
550lbs.
11/12
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
Dayton Superior P90 Connecting Systems Threaded Inserts are mineral-filled nylon inserts designed
for attaching, suspending and fastening objects to precast concrete. They provide the precast
manufacturer with an excellent, cost effective fastening system.
Advantages:
Economical
Light weight
Typical Applications:
Secure benches, picnic tables and other landscape items to concrete bases
Suspend pipes, conduits and other utilities from concrete panels and ceilings
Steel
Form
P90
Insert
Length
(A)
Minimum
Edge
Distance
Minimum
Corner
Distance
Safe
Working
Load
Tension
Safe
Working
Load
Shear
1/4" 20 NC
1-1/2"
1"
3/4"
3"
6"
1,000 lbs.
1,000 lbs.
3/8" 16 NC
1-1/2"
1"
3/4"
3"
6"
1,075 lbs.
1,075 lbs.
1/2" 13 NC
1-5/8"
1-3/8"
3/4"
3-1/2"
7"
1,175 lbs.
1,175 lbs.
1/2" 13 NC
2-5/8"
1-3/8"
3/4"
5-1/2"
11"
2,525 lbs.
2,525 lbs.
5/8" 11 NC
3"
1-1/2"
7/8"
6"
12"
3,375 lbs.
3,375 lbs.
3/4" 10 NC
3-1/4"
1-5/8"
1"
6-1/2"
13"
3,625 lbs.
3,625 lbs.
Structural
Connectors
Bolt
Safe Working Loads provides a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.
Minimum spacing between inserts is twice the corner distance.
11/12
109
NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete
The top of the insert has a round washer face with four nail holes. Nail or bolt insert to side
forms or wet set in face of panel as required. The bottom end has a hot-forged, washer
face hex foot to resist pull-out from the concrete.
Length
Use this versatile insert as a cast-in-place insert or in a core and grout application. Lace and/
or template several inserts together to provide repeat anchorage patterns of two, three,
four or more inserts.
Longer length inserts are available as required. Minimum spacing between the inserts
shown in the chart is twice the minimum corner distance.
Available plain, electro-galvanized, hot-dipped galvanized or epoxy coated as required.
D108A Headed
Dowel Bar Insert
To Order:
Specify: (1) quantity, (2) name, (3) bar size,
(4) overall length, (5) finish.
Example:
300, D108A Headed Dowel Bar Insert,
#5 x 7-1/2" long, plain finish.
Structural
Connectors
Insert
Length
Safe
Working
Load
Tension
Safe
Working
Load
Shear
Minimum
Edge
Distance
Minimum
Corner
Distance
7-1/2"
6,000 lbs.
4,000 lbs.
8"
12"
Flange
Maximum
Diameter
Bolt
A
Engagement
5/8" 11 NC
#4
3/4" 10 NC
#5
9"
9,300 lbs.
6,200 lbs.
11"
15"
2"
1"
7/8" 9 NC
#6
10-1/2"
13,200 lbs.
8,800 lbs.
13"
20"
2-1/4"
1-1/8"
1" 8 NC
#7
12"
18,000 lbs.
12,000 lbs.
16"
24"
2-7/16"
1-1/4"
1-7/8"
7/8"
Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete concrete as calculated from
criteria in ACI 318. Specific applications are the responsibility of the Engineer of Record, not Dayton Superior.
Minimum spacing between inserts is twice the corner distance.
Insert Length to bottom of bolt head.
110
11/12
Rebar Stop An integrated post that acts as a precise stop when inserting rebar
Standard Port Sizes Ports designed to accept standard 0.75" SCH40 PVC; ports use the same size PVC
Stacking Feet Feet used to stabilize the product during shipping and on the shelf while assisting in wire-tying and
acting as a platform for a rebar chair.
E, MAX
E, MIN
F, MAX
F, MIN
#4
13MM
2.14
1.26
0.87
2.14
9.50
0.25
4.63
3.30
4.63
3.30
#5
16MM
2.14
1.26
0.87
2.14
9.50
0.25
4.63
4.13
4.63
4.13
#6
19MM
2.61
1.73
1.14
2.61
13.00
0.25
6.38
4.92
6.38
4.92
#7
22MM
2.61
1.73
1.14
2.61
13.00
0.25
6.38
5.71
6.38
5.71
#8
25MM
2.89
2.01
1.42
2.89
16.52
0.38
8.07
6.50
8.07
6.50
#9
29MM
2.89
2.01
1.42
2.89
16.52
0.38
8.07
7.40
8.07
7.40
#10
32MM
3.04
2.16
1.57
3.04
17.99
0.50
8.75
8.19
8.75
8.19
#11
36MM
3.32
2.32
1.73
3.32
19.54
0.50
9.52
8.98
9.52
8.98
#14
43MM
3.73
2.60
2.01
3.73
24.50
0.50
12.00
11.42
12.00
11.42
#18
57MM
4.77
3.27
2.68
4.77
36.00
0.50
17.75
17.00
17.75
17.00
SLEEVES
PER BAG OF
GROUT
SIZE
#4
13MM
37
#5
16MM
40
#6
19MM
16
#7
22MM
30
#8
25MM
11
#9
29MM
11
#10
32MM
#11
36MM
#14
43MM
#18
57MM
11/12
111
Structural
Connectors
SIZE
How to Specify:
Structural
Connectors
112
11/12
System Advantages
The patented Dowel Bar Splicer System has been engineered, tested and proven to meet or exceed all field standards
and design/engineering practices. The System is strong, easy to use and readily identified as rebar material. The easy
installation requires no special tools or machinery and simplifies the forming operations. There are no extras, such as
wedges, nuts, collars or couplers required and routine cutting, bending, etc., can be easily handled in the field, if required.
The Dayton Superior Dowel Bar Splicer System Advantages:
Strong
Safe
Easy to Use
No Forming Required
System Compliance
Miscellaneous
Connection Inserts
The Dowel Bar Splicer System complies with the following standards/specifications:
11/12
113
System Advantages:
System Compliance
BarLock couplers are test-certified to exceed the requirements of, are
prequalified and approved, or recognized by the following building
approval agencies:
BarLock coupler source material is fabricated under ISO9000 quality standards. BarLock couplers are tested by
independent, certified testing laboratories in four modes of testing: tension, compression, fatigue and cyclic. All tests are
done to the requirements of ICC and/or Caltrans requirements utilizing ASTM A615 grade 60 rebar material. Copies of test
reports are available on request.
Miscellaneous
Connection Inserts
Typical Specification
By specific name:
By generic description:
Mechanical butt splices utilizing lock-shear bolts and internal serrated grip rails within the coupling sleeve. They shall
exceed the specification requirements for both tension and compression specified by ACI 318 and the Uniform Building
code, and be recognized by the International Conference of Building Officials (ICC).
Note: For more information on the BarLock Coupler System, request a copy of the Dayton Superior Rebar Splicing Handbook
114
11/12
F7 Round Cut
Washer
The Dayton Superior F9 Shimming Washers are used between the Shelf Angle Insert and the clip, or
shelf angle, so solid contact can be maintained between the two. F9 shims are available with slot for the 3/4" diameter
Askew Head Bolt. DS_F7ShimmingWasher
F9 Shimming
Washer Dimensions
A
1/8"
1-7/8"
1/8"
3"
1/4"
2"
1/4"
3"
2"
To Order:
Specify: (1) quantity, (2) name, (3) finish.
Example:
13/16"
F9 Shimming Washer
F12 Hanger
Hook
To Order:
Specify: (1) quantity, (2) name, (3) hole size in F12.
Miscellaneous
Connection Inserts
Example:
200 each, F11 Hanger Inserts and F12 Hanger Hooks,
9/23" holes.
11/12
115
Miscellaneous
Connection Inserts
Fast, High Strength, Reliable Concrete Connection Inserts
The P30 Nut Type Slotted Insert uses a spring loaded, zinc-plated, heavy duty 3/4"-10 National Course (NC) threaded nut to
provide fast, efficient and reliable connections. The P31 Strap Type Slotted Insert is used with either the P32 Standard Strap
Anchor or the P33 Slotted Strap Anchor, depending upon your erection requirements. The P34 Threaded Strap Anchor is
used with the P30 Nut Type Slotted Insert.
The design of the strap anchor allows for fast installation of the anchor into the slotted insert. This speeds up the erection
process and saves valuable installation time. As part of the erection process, the strap anchor is welded to the buildings
structural frame to make a ductile connection. All COREWALL products are manufactured from a weldable grade of steel.
Dayton Superior COREWALL slotted inserts are ideal for use in precast concrete industrial wall panels, architectural panels,
structural panels or precast parking structures. The COREWALL slotted inserts are also suitable for use in seismic areas.
116
11/12
C
13/16"
P30 Corewall
Slotted Insert Nut
Type
To Order:
Specify: (1) quantity, (2) name, (3) part number, (4) finish.
For proper connection to the structural
frame of the building, use either a
3/4"-10 NC threaded bolt or rod meeting
ASTM A-325 or SAE Grade 5 Standards.
Example:
200, P30 Corewall Nut Type Slotted Inserts, #CS425, hot-dip galvanized.
Part
Tension Safe
Number Working Load
CS425
CS625
CS825
CS435
CS635
CS835
CS445
CS645
CS845
4,000 lbs.
4,000 lbs.
4,000 lbs.
5,350 lbs.
5,350 lbs.
5,350 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
Shear Safe
Working Load
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
4"
6"
8"
4"
6"
8"
4"
6"
8"
3-3/16"
2-1/2"
5-1/2"
Adjustment
E
2-1/2"
3-3/16"
2-1/2"
7-1/2"
4-1/2"
3-3/16"
2-1/2"
9-1/2"
6-1/2"
3-3/8"
3-1/2"
5-1/2"
2-1/2"
3-3/8"
3-1/2"
7-1/2"
4-1/2"
3-3/8"
3-1/2"
9-1/2"
6-1/2"
3-11/16"
4-1/2"
5-1/2"
2-1/2"
3-11/16"
4-1/2"
7-1/2"
4-1/2"
3-11/16"
4-1/2"
9-1/2"
6-1/2"
Miscellaneous
Connection Inserts
Safe Working Loads provide a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.
11/12
117
3/4"
P33
2 1/8"
4" x 13/16"
slot
L
A
1/2"
P34
1-1/4"
1-1/4"
P32
1-1/16"
P31
5
4
P32 Corewall
Strap Anchor
1.
2.
3.
4.
5.
See following page for the minimum edge distance requirements needed to develop the tension and shear safe working
loads shown in the chart below.
P31 Corewall Strap Type Slotted Insert Selection Chart
Shear Safe Working Load
Miscellaneous
Connection Inserts
Insert Style
Tension Safe
Working Load
Up to 2' Eccentricity
Up to 3' Eccentricity
SA 1425
4,000lbs.
6,650lbs.
SA 1625
4,000lbs.
SA 1825
4,000lbs.
SA 1435
4,000lbs.
4"
4-3/16"
2-1/2"
6,650lbs.
4,000lbs.
6"
4-3/16"
2-1/2"
6,650lbs.
4,000lbs.
8"
4-3/16"
2-1/2"
5,350lbs.
6,650lbs.
4,000lbs.
4"
4-3/8"
3-1/2"
SA 1635
5,350lbs.
6,650lbs.
4,000lbs.
6"
4-3/8"
3-1/2"
SA 1835
5,350lbs.
6,650lbs.
4,000lbs.
8"
4-3/8"
3-1/2"
Safe Working Load provides a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete. Eccentricity is measured from face of insert to
midpoint of the weld connecting the strap anchor to the structural frame.
P33 Slotted
Strap Anchor
P34 Threaded
Channel Strap Anchor
P34 Threaded
Plate Strap Anchor
Part Number
Length
Part Number
Length
Part Number
Length
Part Number
Length
CE 806
6"
CE 906
6"
CE 675
6"
CE 600
6"
CE 808
8"
CE 908
8"
CE 875
8"
CE 800
8"
CE 810
10"
CE 910
10"
CE 1075
10"
CE 1000
10"
CE 812
12"
CE 912
12"
CE 1275
12"
CE 1200
12"
Note: Longer lengths are available on special order. The P34 Threaded Strap Anchor is used with the P30 Nut Type Slotted Insert and P38 Slotted Insert II.
118
11/12
Product Specification:
TECHNICAL DATA:
P38 Nut Type Slotted Anchor Insert Selection Chart
Description
Tension Safe
Working Load
Shear Safe
Working Load
Length (A)
Width (B)
Depth (C)
Length (D)
Adjustment (E)
4,660lbs.
5,150lbs.
4"
5-1/2"
2-1/2"
5-1/4"
2-1/2"
5,500lbs.
6,400lbs.
6"
5-1/2"
2-1/2"
7-1/4"
4-1/2"
5,500lbs.
7,300lbs.
8"
5-1/2"
2-1/2"
9-1/4"
6-1/2"
6,300lbs.
8,600lbs.
4"
6"
3-1/2"
5-1/4"
2-1/2"
6,750lbs.
8,700lbs.
6"
6"
3-1/2"
7-1/4"
4-1/2"
7,100lbs.
8,700lbs.
8"
6"
3-1/2"
9-1/4"
6-1/2"
8,600lbs.
10,700lbs.
4"
6-1/2"
4-1/2"
5-1/4"
2-1/2"
8,800lbs.
10,950lbs.
6"
6-1/2"
4-1/2"
7-1/4"
4-1/2"
9,100lbs.
10,950lbs.
8"
6-1/2"
4-1/2"
9-1/4"
6-1/2"
Safe Working Loads provide a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.
Engineer is responsible to make sure that connecting threaded rod or bolt is strong enough to carry these loads.
Miscellaneous
Connection Inserts
To Order:
Specify: (1) quantity, (2) name, (3) part number,
(4) description, (5) finish.
11/12
119
8"
12"
8"
12"
Corner Detail
Edge Perpendicular
Detail
3/4" Min.
Cover
3"
3/4"
Minimum
Cover
1-1/4"
Slot Detail
1-1/4"
4"
or 6"
2"
2"
4" Insert
3/4" Min.
Cover
2#4
Stepped
Hairpins
3#4
Stepped
Hairpins
Plan
Plan
1-1/2"
3"
1-1/2"
6" Insert
3"
1-1/4"
C
1-1/2"
5/8"
3/4" Min.
Cover
2-1/2"
3/4" Min.
Cover
Section
Corner Detail
3/4" Min.
Cover
4" or
6"
4" or 6"
3"
3 #4
Stepped
Hairpins
Plan
Varies to
suit min.
cover
1-1/4"
#4
Rebar
1'-6"
3/4" Min.
Cover
Plan
11/16"
Stepped Hairpin
1-1/4"
3"
2#4
Stepped
Hairpins
2-1/2"
8" Insert
Section
3"
3-1/2"
Out/Out
Varies
#4
Rebar
1'-6"
Section
120
Section
1-3/4"
Out/Out
11/12
Availability
Dayton Superior Dur-O-Web is shipped in bundles containing 500 ft. (50 pcs. of 10'-0"
long units). Lengths other than 10'-0" can be supplied on special order. The standard
finish is bright basic. Galvanized wire, hot dipped galvanized and epoxy coated finishes
are also available on special order.
P12D Dur-O-Web
Shear Reinforcement
While Dur-O-Web is normally supplied with uniform spacing of vertical wires, variable spacing is available.
Benefits
Ideal shear reinforcement for use in prestressed/precast concrete double tees or other precast elements having narrow
webs or where space is limited.
Ready to use.
Reduces costs by eliminating the cutting and bending of standard rebars or mesh.
Easy to place.
The ability to vary wire diameters and spacing guarantees the most economical solution to your reinforcement requirements
Approvals
The use of Dayton Superior Dur-O-Web Shear Reinforcement to replace open and closed stirrups is allowed by American
Concrete Institute (ACI-318) Standard Building Code Requirements for Concrete Structures, and Canadian Standards
Association Standard CAN3A23.3 Design of Concrete Structures for Buildings.
11/12
Wire
Wire
Gauge Diameter
0
1
2
1/4"
3
4
5
6
7
8
9
10
0.306"
0.283"
0.263"
0.250"
0.244"
0.225"
0.207"
0.192"
0.177"
0.162"
0.148"
0.135"
Steel
Minimum
Weight
Area
Side Wire
lb. per ft.
(sq. in.)
Gauge
0.074
0.063
0.054"
0.049"
0.047"
0.040"
0.034"
0.029"
0.025"
0.021"
0.017"
0.014"
0.251
0.214
0.184
0.167
0.158
0.135
0.114
0.098
0.084
0.070
0.059
0.049
Area of Steel (sq. in.) per Lineal Foot at Indicated Main Shear Reinforcement Spacing
2"
3"
11"
12"
0.444
0.296
0.222 0.178
0.148
0.127 0.118
0.111
0.099 0.089
0.081
0.074
0.378
0.252
0.189 0.151
0.128
0.108 0.101
0.095
0.084 0.076
0.069
0.063
0.324
0.216
0.162 0.130
0.108
0.093 0.086
0.081
0.072 0.065
0.059
0.054
0.294
0.196
0.147 0.118
0.098
0.084 0.078
0.074
0.065 0.059
0.053
0.049
0.282
0.188
0.141 0.113
0.094
0.081 0.075
0.071
0.063 0.056
0.051
0.047
10
0.240
0.160
0.120 0.096
0.080
0.069 0.064
0.060
0.053 0.048
0.044
0.040
10
0.202
0.136
0.102 0.082
0.068
0.058 0.054
0.051
0.045 0.041
0.037
0.034
10
0.174
0.116
0.087 0.070
0.058
0.050 0.046
0.044
0.039 0.035
0.032
0.029
10
0.150
0.100
0.075 0.060
0.050
0.043 0.040
0.038
0.033 0.030
0.027
0.025
10
0.126
0.084
0.062 0.050
0.042
0.036 0.034
0.032
0.028 0.025
0.023
0.021
10
0.102
0.068
0.051 0.041
0.034
0.029 0.027
0.026
0.023 0.020
0.019
0.017
10
0.084
0.056
0.042 0.034
0.028
0.024 0.022
0.021
0.019 0.017
0.015
0.014
4"
5"
6"
7"
7-1/2"
8"
9"
10"
121
Miscellaneous
Connection Inserts
Example:
A-82 Standard Specification for Steel Wire, Plain, for Concrete Reinforcement
A-185 Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement
Weight Calculation
The sample calculation, below, shows how to calculate the approximate weight of steel used in different Dur-O-Web assemblies:
P12D Dur-O-Web
Vertical wires:
4 pcs. of 7 gauge
Height:
22" overall
Length"
Vertical wires = 22" 12" per ft. x 12" per ft. 6"
centers x .214 lb. per ft. x 10 ft.
3.36 lb.
11.23 lb.
10'-0"
2" Minimum
7.87 lb.
Dur-O-Web
Dur-O-Web
A H D
1" Concrete
Cover Assumed
2" Minimum
Bridge Beams
Double Tee
Dimension
"A"
P12D Dur-O-Web
Overall Height "H"
8'
2'
6'
10'
4'
8'
12'
6'
10'
14'
8'
12'
16'
10'
14'
18'
12'
16'
20'
14'
18'
22'
16'
20'
24'
18'
22'
32'
26'
30'
Miscellaneous
Connection Inserts
Depth of Concrete
Member "D"
Vertical Shear
Reinforcement
Horizontal Side
Wires
2"
Minimum
2"
Minimum
Spacing
Spacing
To Order:
Specify: (1) quantity, (2) overall height H, (3) name,
(4) gauge and spacing of vertical wires, (5) gauge of side wires,
(6) overall length (7) finish.
Example:
275, 22" high, P12D Dur-O-Web, 1 gauge verticals at 6" centers,
7 gauge side wires x 10 ft. long, bright basic finish.
122
11/12
DS_P24
The Dayton Superior P24 Delta Tie is a unique insulated precast concrete panel
connector. It allows the precaster to fabricate a highly energy-efficient, insulated
precast concrete sandwich wall panel using the insulating foam of his choice.
This versatile connector allows the foam insulation to be placed from panel edge
to panel edge, eliminating thermal bridges and costly energy loss. The foam
insulation is sandwiched between two concrete wythes, or layers, to form a longlasting, energy-efficient precast concrete sandwich wall panel. The three wythes
are tied together using P24 Delta Ties. Spacing of the Delta Ties varies, based on
the panels required composite moment capacity.
Advantages
Increased load bearing.
Design flexibility.
Sandwich Panel
Connectors
11/12
123
1/2" Typ.
The standard Delta Tie dimensions are shown in the accompanying detail.
The connector is designed so that it can be oriented in the panel either on end or side,
depending on the thickness of the panel. For example, the 5" x 7" size can be used on
its side in a six-inch panel or on end for thicker panels. The Delta Tie can be used with
any rigid insulation from 1" to 4" thick. This versatile, dual-use feature adds to the
Delta Ties effective application compatibility and, at the same time, reduces inventory
and storage requirements.
5"
3"
5"
In individual connector specimen and full size panel tests the Delta Tie has exhibited
excellent loading behavior and load capacities.
7"
Design Flexibility
Due to the composite action gained by using the Delta Tie, panels may be cast in longer lengths or with thinner concrete
wythes.
Cost Savings
The Delta Tie design provides a fast and easy installation to save labor. It produces stiffer panels to lessen handling,
storage and transportation concerns. The connectors design flexibility allows the cost saving attributes to be designed
into the panel. Delta Tie connectors are purchased as a separate item, allowing the precaster to provide the foam
insulation of his choice.
3,220lbs. in shear.
3,100lbs. in tension.
Maximum recommended spacing is 8 square feet of panel per panel connector. For spacing in excess of 8 square feet of
panel per connector, contact a Dayton Superior Technical Assistance.
NFPA 285
ASTM E-119
To Order:
Specify: (1) quantity, (2) name.
Sandwich Panel
Connectors
Example:
500, P24 Delta Ties.
124
11/12
60%
50%
40%
30%
20%
10%
0%
10
No Composite Action
14000
12000
2-2-2
10000
Sandwich Panel
Connectors
16000
3-2-3
18000
8000
6000
4000
2000
0
0%
10%
20%
30%
40%
50%
60%
70%
Percent Composite
11/12
125
Sandwich Panel
Connectors
126
11/12
Top Wire
Diagonal
Wire
Height
3.937"
Bottom Wire
3.937"
7.875"
INSTALLATION
4. Install top width mesh and tie to girder, or to prestressed cables for support and proper positioning in
center of top width. Place remaining concrete to form
top width.
Top Wire:
Height:
How to Order:
Length:
Bottom Wire:
Finish:
3'-11" to 34'-5"
Plain or mill galvanized
Diagonal Wire:
Pricing:
11/12
Manufacturing Location:
Kankakee, Illinois
Sandwich Panel
Connectors
127
12 ga.
Diameter
The Dayton Superior Connector Pin is used to tie two wythes together. The pins
work in tension and compression to resist wind pressure and suction. The pins also
prevent bowing and separation of the individual wythes of the panel. The pins
are produced from type 304 stainless steel for excellent corrosion resistance. Since
the pins are made from small diameter wire, they are flexible and do not offer any
resistance to movement from thermal stresses that build up in the panel.
Length
Length
The P15 Type M Connector Pin is available in 4-3/4", 5-1/2" and 6-1/4" lengths. The
P14 Type L Connector Pin is available in lengths of 4-3/4", 5-1/2", 6-1/4" or 7-1/2".
P14 Type L
Maximum pin spacing is 4'-0" on center, or one pin for each 5 sq. ft. of panel area.
Connector Pin
However, pins should be spaced at 24" maximum on center along the panel edges.
P15 Type M
Connector Pin
Note: Larger panel sizes may have non-load bearing wythe divided into two or more sections.
To Order:
Specify: (1) quantity, (2) name, (3) length.
Example:
200, P14 Type L Connector Pins, 5-1/2" length.
Connector Pin Selection Chart
Safe Working Load Per Pin (lbs.)
Insulation
Thickness
Tension
1"
300
1,900
1-1/2"
300
800
2"
300
450
2-1/2"
300
300
Compression
1-1/4"
1-1/2"
1-3/4"
2"
2-1/2"
5'-0"
7'-0"
8'-6"
10'-0"
12'-0"
17'-0"
Sandwich Panel
Connectors
128
11/12
DS_P9
1-1/2"
Place the connectors at the edge of the foam insulation so the body of the
tie is at the joint line between two pieces of foam. Next, the ends of the
tie are rotated 90 so they bear against the foam insulation. Spacing of
the panel connectors are per job requirements.
B
(Insulation
Thickness)
After the panel ties have been attached to the foam insulation, they are
placed on the freshly placed bottom wythe of concrete. Later, the top
wythe of concrete is placed.
The chart, below, lists the sizes of panel ties produced in the ast for
various precasters. Other sizes can be produced on special order.
P9 Precast Sandwich Panel Tie
To Order:
Specify: (1) quantity, (2) name, (3) A & B dimensions
(4) finish.
Example:
3"
4"
4"
5"
6"
7"
8"
1"
1"
2"
3"
3"
3"
3"
DS_P37
A
1/4" Diameter
Edge distance requirements are 6" minimum center line to the panel end and
4" minimum center line to the panels edge. Place connectors parallel to the
length of the panel.
1"
To Order:
4"
Example:
1200, P37 M Anchor Shear Connectors, No. CP107.
Maximum
Insulation
Thickness
CP106
2"
6"
2"
CP107
2"
7"
3"
CP206
1-1/2"
6"
2-1/2"
CP207
1-1/2"
7"
3-1/2"
11/12
Insulation
Sandwich Panel
Connectors
Style
Typical Installation
129
130
11/12
Miscellaneous
Products
Note: For more information on the complete prestressing system or individual components, request a copy of the
Prestress Strand Deflection Device Handbook
11/12
131
Precast Bracing
T14 Precast Wall Braces
DS_T14
The Dayton Superior T14 Precast Wall Braces are all steel, heavy duty wall braces designed to quickly and easily align and
brace tilt-up wall panels. Rough adjustment of the T14 braces is easily accomplished by telescoping the pipes to the nearest
incremental hole.
Final adjustment is then achieved by simply turning the brace. Dayton Superior wall braces are available in numerous sizes
to provide a continuous range of panel heights of fifty feet or more. Refer to the chart below for additional information.
Wall Plate
Wall
Plate
Ball
Bearing
Coupler
Adjusting
Screw
Example:
Telescoping Pipes
Danger! To prevent
accidental removal
of alignment pin,
insert a 10d double
headed nail through
hole in alignment
pin, bending the
protruding portion of
the nail to a 45 degree
minimum angle
To Order:
Adjusting
Screw
Foot Plate
Foot
Plate
To Order:
Specify: (1) quantity, (2) name, (3) model.
Miscellaneous
Products
Example:
40, T15 Pipe Brace Extension, 5' extension for B8 braces.
132
11/12
Precast Bracing
Brace Loading
DS_BraceLoading
Bracing recommendations are for the sole purpose of temporarily bracing fully erected concrete panels during construction
- against wind loads only. This temporary bracing design is based on The American Society of Civil Engineers (ASCE)
Minimum Design Loads for Building and other Structures, as recommended by the Tilt-up Concrete Associations Guideline
for Temporary Wind Bracing of Tilt-up Concrete Panels During Construction, TCA Guideline 1-05. The ASCE standard and
the TCA guideline allow the basic wind speed, which is based on a 50-year mean recurrence interval, to be multiplied by a
reduction factor for a 5-year mean recurrence interval which determines the construction wind speed used in the design of
bracing systems.
Brace anchors and main, knee, lateral and/or end braces are not designed or intended to sustain impact loads. Precautions
must be taken to arrange the panel erection sequence so as to avoid the potential for impacting upright panels or portions
of the bracing system. Bracing recommendations for other loads or forces that might be applied to the bracing system
are beyond the scope of Dayton Superior. For bracing recommendations other than wind loads, the user should engage a
design agency with capabilities of performing such a service.
Brace Removal
This bracing system is designed to temporarily support panels against wind loads until the building structure is complete
and self supporting. The bracing system should never be disconnected or removed until the panels are secured by the
permanent structural connections and all lateral load resisting systems are in place.
If the structural documents do not indicate when the temporary bracing system can be removed, the engineer of record
should be consulted.
Panel should be plumb with braces and knee braces installed before crane releases panel.
Lateral bracing should be installed immediately upon the crane and crew clearing the braces and before the next
panel is erected.
Lateral bracing must be continuous, connected at each brace, and tied off with end braces at the end of each line.
End braces to ground and/or cross braces must be installed every 100 ft. to prevent lateral movement of braces and
to provide total brace stability.
All members of the brace system must be in place and secured at the end of each day.
Knee brace must be firmly fixed at bottom end to prevent possible upward buckling of main brace.
Do not erect panels or continue working during excessive windy or adverse weather conditions.
All brace inserts should be a minimum of 12" from any panel edge, opening, control joint or construction joint.
Panel bracing is designed to withstand specified wind loads until panels are connected to the structural system of the
building. Do not remove any members of the bracing system until all structural connections are completed.
Use only the brace type as noted on the Panel Layout Sheet. No substitute brace hardware shall be used and all
braces must be positioned at the specified locations.
For special bracing conditions that require deviation from the bracing dimensions shown on the Panel Layout Sheet
contact Dayton Superior for recommendations.
See Panel Layout Sheet for type of brace, number of braces per panel, as well as knee and lateral bracing requirements.
Welding or bolting the tilt-up panels in place might preclude the use of braces.
After winds of 35 mph or more have been experienced at the job site, the tilt-up contractor must check the tightness
of the bolts that secure the wall and foot plates to the concrete. Re-tightening of these bolts to the proper torque
will assure that the pipe braces are secure.
The safe working load of the panels bracing system may be drastically reduced if other types of brace anchors are
used as part of this projects bracing system, other than specified brace anchors.
Warning! Failure to install knee, lateral and end braces (when required) will greatly reduce the safe working load of the
specified brace and may allow panels to fall causing severe injury or death.
11/12
133
Miscellaneous
Products
Safety Notes:
Precast Bracing
Bracing to Cylindrical Deadman
DS_CylindricalDeadman
Use the chart at the right to select the proper size deadman
if your project requires the use of a deadman for brace
attachment in lieu of an anchor cast into a floor slab.
24"
30"
36"
42"
48"
Diameter Diameter Diameter Diameter Diameter
2'-0"
.94
1.47
2.12
2.89
3.77
2'-6"
1.18
1.84
2.65
3.61
4.71
3'-0"
1.41
2.21
3.18
4.33
5.65
3'-6"
1.65
2.58
3.71
5.05
6.60
4'-0"
1.89
2.95
4.24
5.77
7.54
4'-6"
2.12
3.31
4.77
6.49
8.48
5'-0"
2.36
3.68
5.30
7.22
9.42
Example:
5'-6"
2.59
4.05
5.83
7.94
10.37
6'-0"
2.83
4.42
6.36
8.66
11.31
6'-6"
3.06
4.79
6.89
9.38
12.25
24" 7'-0"
7'-0"
3.30
5.15
7.42
10.10
13.19
30" 4'-6"
7'-6"
3.54
5.52
7.95
10.82
14.14
36" 3'-6"
8'-0"
3.77
5.89
8.48
11.54
15.08
8'-6"
4.01
6.26
9.01
12.27
16.02
9'-0"
4.24
6.63
9.54
12.99
16.96
9'-6"
4.48
6.99
10.07
13.71
17.91
10'-0"
4.71
7.36
10.60
14.43
18.85
4 #4 Vertical Bars
3 #3 Ties @ 8" o.c.
3/4" Diameter
Cast-in Floor Brace
Anchor or T13
Coil-Anchors 3/4"
Diameter x 4-1/2"
Long
42" 2'-6"
6"
Max
Brace Maintenance
During the construction process, braces may be exposed to adverse conditions that could damage or render them unusable.
Braces should be inspected for proper operation, damage and wear after each use.
This inspection is typically performed by a Dayton Superior Certified Precast Dealer when the braces are returned.
However, when braces are transferred from one job to another without being returned to Dayton Superior or its dealer for
maintenance, the user must inspect all braces prior to their being reused.
This inspection should check for missing parts, parts, wear, dings, kinks, straightness, indication of any application of heat
and/or other damage.
Any brace that shows signs of wear, has missing parts, damage, or is questionable should be set aside and not used.
Miscellaneous
Products
134
11/12
Precast Bracing
Accubrace Total Bracing System DS_Accubrace
Accubrace is a total bracing system of Braces and Helical Ground Anchors engineered for unsurpassed speed and efficiency for
tilt-up or pre-cast applications. Installed by Dayton Superior professionals, this system provides an affordable, engineered solution.
Braces
A high-capacity brace designed to allow increased brace spacing for temporary stabilization of concrete wall panels.
HGA Extension
Certain sites where the foundation soils are lower strength may require the use of an HGA
Extension. This shaft is the same section (1" square bar) but is 4' in length and has a 10" helical
plate set at 10" from the top of the extension.
Transition
Brace
Connector
Advantages:
Reduces the number of braces needed by up to 60% to provide accelerated construction
Bracing on the inside of wall without a slab avoids holes in slab and/or vapor barrier
Integrated in-line connection to the brace with the HGA and Transition Brace Connector
Recipient of the 2007 Robert Aiken Innovation Award sponsored by the TCA.
Part #
Standard
Brace
Length
Brace
Length
Min.
Brace
Length
Max
A21B
21'
21'-0"
23'-3"
23,200 lb.
15,500 lb
230 lb
A27B
26'
25'-7"
27'-3"
17,250 lb.
11,500 lb
265 lb
A32B
32'
30'-9"
33'-3"
22,500 lb.
15,000 lb
A37B
37'
35'-9"
38'-3"
18,000 lb.
12,000 lb
A42B
42'
40'-9"
43'-3"
16,500 lb.
11,000 lb
695 lb
A52B
52'
50'-9"
53'-3"
16,500 lb.
11,000 lb
1030 lb
11/12
HGA
Brace
Weight*
HGA
Extension
Description
SWl
Tension
Length
405 lb
Standard HGA
12,000 lb
7'-2"
460 lb
15,000 lb
4'-0"
135
Miscellaneous
Products
Formliners
DS_Elastotex
Elasto-Tex formliner is produced from a two-component urethane and is mold-bonded to 1/2" HDO plywood, ready for
mounting to your forms. It is the preferred formliner material when 25 or more pours, or reuses, are required. Elasto-Tex is
available in all existing formliner patterns, as well as custom textures.
Its stiffness and compressive strength hold the desired shape during concrete placement and vibration. Its flexibility
accommodates almost any desired texture or sculpture effect. The built-in resilience and toughness of Elasto-Tex result in
an exceptional capability for precise reproduction of the desired pattern or texture. Elasto-Tex improved wear resistance
provides high reuse factors that could be in excess of 100 times.
DS_Vinyltite
For sharp-edged trapezoidal textures, choose Vinyltite formliners. The use of our Vinyltite formliner eliminates the costly
labor involved in wood construction. You get continuous uniform texture reproduction pour after pour. Vinyltite is
impervious to moisture and it wont swell, bulge or distort design integrity.
Vinyltite is easy to use with superior results. Vinyltite pre-drilled nailing strip lets you attach the formliner to the concrete
slab or form without splitting or tearing. No more unsightly nail head impressions, and less sacking and patching costs.
Interlocking joints ensure proper alignment and prevent concrete leakage. Connect the pieces to form large panel sections
with no seam lines.
Wide ranges of widths and lengths. Lightweight, easy to handle and made of rigid HIPS or ABS plastic, Vinyltite comes
in Single Use, Medium Use, or Heavy Reuse materials. Profiles are available in 6 inches to 18 inches wide, extruded to
specified lengths up to 45'-0" for clean installation every time.
DS_Thermoform
Thermoform Concrete formliners are rigid plastic liners that are used to achieve detailed patterns and textured concrete
surfaces for precast architectural concrete. You may select from a variety of patterns, or custom order to fit your needs
at only a nominal additional cost. All patterns are available in three different ranges: Single Use, Medium Reuse and High
Reuse.
The Single Use, made from styrene, is ideal where the formliner will be used only once. The Medium Reuse, made from ABS
materials, can be used up to 10 times. The High Reuse can be used up to 20 times under most conditions.
The vacuum-forming technology used in this product line allows virtually unlimited texturing opportunities, offering the
most flexibility in custom designed patterns. This low cost reproduction process allows you to add exceptional economic
options to the design integrity of your precast concrete projects. Due to the stretching of the plastic sheet material that
occurs during the reshaping of the thermoforming process, some patterns with a high degree of texture or relief should not
be produced in the thinner, single-use material. Normally supplied in 4' x 10' sheets.
Miscellaneous
Products
136
11/12
Rustication
Rustication Strips
Specify Rustication Strips for concrete surfaces when distinct features or reveals are required.
Each Rustication Strip is a durable, precision molded piece which contains a metal strap core for attachment to concrete
formwork. Rustication Strips are available in a variety of standard shapes to meet almost any project requirement.
Dayton Superior Rustication Strips are manufactured in premium ElastoTex material for extensive reuse.
Advantages:
30755
3/4" x 3/4" x 1/4"
30756 1" x 3/4" x 1/2"
30757 1-1/2" x 3/4" x 1"
30758 2" x 3/4" x 1-1/2"
30759 1" x 1" x 1/2"
30760
1-1/2"
x 1" x 1"
30761 2" x 1" x 1-1/2"
30762 2-1/2" x 1"
x 1-3/4"
30763 3" x 1" x 2-1/4"
30764 4" x 1" x 3-1/4"
30765 5" x 1" x 4-1/4"
30766 6" x 1" x 5-1/4"
30767 1-1/2" x 1-1/2" x 1"
30768 2" x 1-1/2" x 1-1/2"
30769 3" x 1-1/2" x 2"
30770
2" x 2" x 1"
30771
3" x 2" x 2"
30772
4" x 2" x 3"
Slope
P/C Base Ht.
30776
3/4" x 3.4" x
1-1/16"
1" x 1" x
1-7/16"
30777
30778
1-1/2" x 1-1/2" x 2-1/16"
11/12
Miscellaneous
Products
137
Other Products
Rustications, Chamfers and Coverers
Rustications, chamfers and other products manufactured by Victory Bear provide innovative solutions to the designer and
the contractor. These products provide significant labor savings in the installation of the rustications and chamfers along
with eliminating much of the building finish problems which occur with wood products. And now these products can be
found at a Dayton Superior distribution center near you.
SLAB SAVER
VB_SlabSaver
2' PVC Edge pieces installed in the bottom of wall panels used to protect floors during
panel erection, eliminating damage to the floor slab during panel erection.
RUSTICATION
VB_Rustication
" x 45 degree PVC rustication in widths of 2.25", 2.5", 3.5", 5.5", 8.0" and 11.5". These
have the patented Flex Edge Seal, insuring a tight joint with the concrete slab and
these utilize the Victory Bear Base Clip for easy installation. 1/2" x 60 degree low profile
rustication also available.
SNAP RUSTICATION
VB_SnapRustication
" Triangular PVC rustication which opens to allow easy installation and then snaps shut
to prevent concrete seepage.
BULKHEAD
VB_Bulkhead
" PVC bulkhead chamfer providing chamfer on both sides of the bulkhead. This product
is used with both " plywood and 2x materials. It features both the patented Flex Edge
Seal and utilizes the Base Clip to secure the product to the floor slab.
BULLNOSE VB_Bullnose
PVC Single Bullnose chamfers provide the radius edges when the designer desires a
different effect from the traditional triangular building edges.
CHAMFERS
VB_Chamfers
" x 45 degree PVC chamfers in both single and double chamfer versions. This product
utilizes the patented Flex Edge Seal and is attached to the floor slab with adhesives or
traditional nails or screws.
VB_ChamfersLowProfile
1/2" x 60 degree PVC chamfers in both single and double chamfer versions. This product
utilizes the patented Flex Edge Seal and is attached to the floor slab with adhesives or
traditional nails or screws.
VB_DripEdgeChamfer
" x 45 degree PVC drip edge chamfer for use where doors, windows, dock doors and
archways require both a chamfer and drip edge. This product utilizes the patented Flex
Edge Seal and is attached to the floor slab with adhesives or traditional nails or screws.
VB_RecessedWindowSystem
A unique utilization of several of the above products with a recessed window chamfer to
add a classic detail for doors and windows in the concrete wall panels.
JOINT COVER
VB_JointCover
PVC Joint Covers provide the building owner an attractive cover for the joints inside of
the building. Joint Covers will fit into panel joints between " and 1" gaps.
VB_SawCutCover
Miscellaneous
Products
PVC Saw Cut Cover temporarily seals the floor slab joints with a unique low profile design.
138
11/12
Other Products
DS_P8A
Dayton Superior P8A Architectural Post Forms are used with precast
concrete panels in the construction of highway sound barriers. Twenty
(20) standard sizes are available. Surface textures can be applied to
the concrete posts with the use of one of the many Dayton Superior
formliner patterns.
DS_P8P
Dayton Superior standard pile forms are available for piles in single or
double configurations up to 24" square for free-standing casting.
Heavy duty construction and quality workmanship means long form life.
Miscellaneous
Products
11/12
139
Other Products
PLW EZ Lok Wheel
DS_PLW
Made from engineered composite resins, the E-Z Lok Wheel was designed for use in
situations where a lightweight wheel is not sufficient to maintain proper location of the
reinforcement. Once attached, this wheel will stay in place.
The unique symmetrical design maintains a consistent cover, regardless of the rebar size.
With a wider hub, the E-Z Lok Wheel will not rack or fall off. The E-Z Lok Wheel offers
flexibility and strength with multiple hub diameters for rebar sizes from 3/8" (No. 3) to 3/4" (No.
6) and is furnished in a variety of clearances.
To Order:
The E-Z Lok Wheel meets all requirements and qualifies as a CRSI Class 1
Bar Support. Available in the following cover heights: 1-1/2", 2-1/2" and
3". Sold in full cartons only.
Example:
The Space Wheel meets all requirements and qualifies as a CRSI Class 1 Bar Support. Available
in cover heights from 3/8" to 3". Sold in full cartons only.
Miscellaneous
Products
140
11/12
Other Products
Tower Bar Chair
DS_TowerBarChair
Tower Bar Chairs are used to support widely spaced, light steel in slab and deck construction. Each
bar chair provides two cover heights that are clearly marked for field identification. Available in 3/4"
to 2-1/2" cover heights and sold in full cartons only.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
2 cartons (900), 121288, Tower Bar Chairs, 1-3/4" to 2" cover.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
PTC Tower
High Chair
E-Z Chair
DS_EZChair
E-Z Chairs are designed for superior strength and stability. They are well suited for
tiltup, precast and poured-in-place slab applications. They are available in 3/4" to
6" cover heights for rebar sizes up to #11. E-Z Chairs are sold in full cartons only.
An Optional Sand Plate is available for use on grade or in sandwich panel
applications.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
4 cartons (700), 121271, E-Z Chairs, 4" cover.
Castle Chair
DS_CastleChair
Castle Chairs are uniquely designed with a wide base ring to provide stability on poorly compacted or
expansive soils. Each Castle Chair offers two cover heights to allow for variation in grading. They are
strong enough to carry the weight of ironworkers and concrete finishers, but will not damage moisture
protection membranes. Castle Chairs are available in 1-1/2" to 4-1/4" cover heights and are sold in full
cartons only.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
2 cartons (700), 122837, Castle Chairs, 2-1/2" to 2-3/4" cover.
11/12
141
Other Products
X-Chair
DS_XChair
X-Chairs are light weight, inexpensive chairs used for supporting rebar and wire mesh in horizontal
applications. The X-Chairs novel design produces a very strong support with minimal surface contact.
X-Chairs are available in 1/2" to 2" cover heights and are sold in full cartons only.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
PXC X-Chair
DS_EZLokSlabBolster
E-Z LOK Slab Bolster provides a strong, stable support and spacer for
rebar in slab or wall applications. The E-Z LOK Slab Bolster can be used in
individual 32" sections or the sections can be snapped together to satisfy
any job-required length. E-Z LOK Slab Bolster is available in 3/4" to 3" cover
heights and is sold in full cartons only.
To Order:
Specify: (1) quantity, (2) name, (3) cover height.
Example:
2 cartons (300), 78066, E-Z LOK Slab Bolster, 2" cover.
DS_PSBUStronbackSBU
Supports top layer in Double Mat application, rebar or wire mesh, slabs,
heavy duty on-grade, corrugated decking, side-form spacer-belowgrade applications only, precast. Cover heights from 1" to 3-1/4" (1/4"
increments)
To Order:
No overlap required
Example:
Panel Pads
DS_PanelPad
1/2" Thick
Miscellaneous
Products
Panel Pads were created especially for use in the precast industry for stacking.
When placed on top of the precast concrete elements, the Panel Pads will
support the weight of additional elements without damage to either element.
The unique bubble design allows the precast materials to cure uniformly.
Panel Pads are manufactured to snap in half.
The 2-1/2" x 5-1/2" pads are spaced around the
To Order:
precast unit.
Specify: (1) quantity, (2) name.
Example:
5-1/2"
142
11/12
Other Products
Slab Bolster
DS_SlabBolster
Rebar
Dayton Superior Slab Bolster is used to support lower slab steel from
the slab form. Legs are spaced on 5" centers. Available in 3/4" to 3"
heights in 5" lengths and in bright basic, galvanized, plastic protected
or stainless steel protected.
Slab
Bolster
Slab Bolster
Beam
Bolster
Rebar
Dayton Superior Beam Bolster is used to support lower beam steel from
the soffit form. Legs are spaced on 2-1/2" centers. Available in 1-1/2"
to 5" heights in 5" lengths. Manufactured in bright basic, galvanized,
plastic protected or stainless steel protected.
Beam Bolster
Continuous
High Chair
Rebar
Rebar
High
Chair
Rebar
Dayton Superior Bar Chair is used to support widely spaced light steel in
slab construction. Available in 3/4" to 2" heights in bright basic, plastic
Bar Chair
protected, galvanized and stainless steel protected.
Bar
Chair
Rebar
Joist Chair
Miscellaneous
Products
Joist Chair
11/12
143
Other Products
K50 Void Retention Insert DS_
K50VoidRetentionInsert
The Dayton Superior K50 Void Retention Inserts primary function is to
conveniently position and firmly hold in place void tubes used in precast slabs,
piles, box beams, etc. Use of the K50 inserts eliminates the possibility of the
voids floating to the surface when concrete is placed in the forms. The K50
insert is injection-molded from nonreactive, noncorrosive thermoplastic and is
designed to fit 10"- and 12"-diameter voids.
K50 Void
Retention Insert
3"
2"
2-3/4"
9-1/4"
To Order:
Specify: (1) quantity, (2) name.
Example:
200, K50 Void Retention Inserts.
DS_H13RoundVoidHoldDown
The Dayton Superior Round Void Hold Down is a one piece unit that completely encompasses the
round void tube and is attached to your form using a standard 3/4" coil bolt. This prevents movement
in any direction of the void tube. Maintained in stock for 10" and 12" OD Diameter Void Tubes, other
sizes available.
To Order:
Specify: (1) quantity, (2) dia of tube (4) plain or galvanized finsih.
Example:
200, H13 12" Round Hold Down, Plain.
Miscellaneous
Products
144
11/12
Other Products
P80 Shim Strips
DS_P80ShimStrips
Dayton Superior P80 Shim Strips assure accurate placing and leveling of tilt-up panels and other architectural and structural
components because they:
are made in convenient thicknesses, lengths and widths allowing precise leveling and alignment.
are less expensive and safer than steel. They have extreme stability and eliminate rust-stained concrete and spalling.
are size scored for convenience of application. Prevent waste material can be readily picked up and stored in the
open for future use.
are available from stock in thicknesses of 1/16", 1/8" and 1/4" and lengths of 3" and 4". The widths of 3" x 24" are
scored every 3" and the widths of 4" x 24" are scored every 2". This allows for easy snap off as needed. Additional sizes
available on request.
are impervious to liquids, ground chemicals, alkalis and microorganisms. The continuing performance characteristics
are stable and predictable.
will not rust, rot or leach when exposed to wet surfaces and have no odor.
eliminate the need for saws, hand tools or cutters. A definite saving in time, labor and money is realized. The strips
are easily applied and lie flat.
decrease damage potential to the adjacent concrete components. Point projection of aggregate is absorbed without
fracture or effect on the load-bearing characteristics.
Engineering Data: The pertinent physical properties of Dayton Superior plastic shims are presented as follows:
Negligible cold flow characteristics; i.e., less than 1% at 1,000 psi and
73F. for 10,000 hours.
P81 Shimpak
To Order:
Specify: (1) quantity, (2) name, (3) length.
Example:
300, P80 Shim Strips, 1/4" x 4".
DS_P81Shimpak
Precast Element
P81 Shimpaks
Popular sizes are 4" x 6" and 4" x 4" packs which are 1-1/16" thick. Shimpaks
are made up of shims in the following thickness sequence: one 1/16", three To Order:
1/4" and two 1/8". Tilt-up panels can be levelled within 1/16" by removing or Specify: (1) quantity, (2) name, (3) size.
adding one or more elements.
Shimpaks are held together with a resilient band for easy removal or
addition of elements.
11/12
Foundation or other
structural member.
Example:
Miscellaneous
Products
145
Other Products
P82 Bearing Strips
DS_P82Bearing Strips
Available in full cartons only. Each carton holds 300 2" x 48" strips.
Thicknesses of 1/8" and 1/4" in stock. Lengths of 48" in stock. Widths of 24", scored at 2" intervals for easy snap off and
flexibility in use. Alternate sizes or scorings available on request.
Width
Thickness
Length
To Order:
Slot Size
Example:
2 cartons, P82 Bearing Strips, 1/4" x 48".
P83 Horseshoe Spacer Selection Chart
Width
Length
2"
3"
Thickness
13/16" x 2-7/16"
3"
4"
13/16" x 2-15/16"
Slot Size
DS_P84KorolathCorePlugs
Plug numbers refer to the diameter of the core holes, not the thickness of the plank
Number
Diameter
Plugs/Carton
400
4"
1,000
Example:
600
6"
2,000
800
8"
1,000
To Order:
146
11/12
Other Products
F67, F68, and F69 Ceiling Hangers
F67 Ceiling Hanger
DS_F67F68F69CeilingHangers
3/8"
4"
3/8"
diameter
9"
or 13"
1"
2"
3/4"
2"
5/8"
3/8"
diameter
6"
/2"
1-1
3/8"
diameter
"
7/8
"
7/8
"
7/8
1"
1"
F68
F67
Flexicore Deck
2"
Topping
6"
or 10"
2"
Topping
F69
2"
Topping
Hollow Core
Slab
F69
F68
F67
1"
Ceiling hangers can be placed where required but are commonly spaced at 2 ft. intervals throughout the beam or slab
length to provide for future hanger requirements. All hangers are made from galvanized stock.
Gauge
Type
Type
16
F67
200 lbs.
F68, F69
400 lbs.
12
F67
400 lbs.
F68, F69
600 lbs.
Example:
Note: Hangers must have minimum of 2" topping slab in place and properly cured to adequately develop
safe working load. With properly applied topping, approximate safety factor is 3 to 1.
To Order:
DS_F75MarbleFacingAnchor
The Dayton Superior F75 Marble Facing Anchor is a special stainless steel anchor
used for anchoring marble, slate, thin limestone, etc., to precast work. The hooks
are placed into predrilled holes in the marble and poured in with the concrete. Other
sizes are available on special order.
To Order:
4"
2-1/2"
8 Gauge
Stainless Steel
Wire Type 430
or 304
Miscellaneous
Products
2-3/4"
11/12
147
Other Products
Cushion-Lock Reglet Type B4
PVC Construction
100% Leakproof
10 ft. Lengths
DS_CushionLock
The advanced design of this reglet offers a number of exclusive features, yet the
in-place cost is actually lower than that of conventional reglets. The completely
enclosed design of the B4 Reglet prevents any concrete from entering during
pouring operation. Just prior to the installation of the counter-flashing, the
integral protective strip is pulled off, exposing a clean recess ready to receive the
counterflashing and no caulking is needed as the snap-in and lock-in patented
features of this reglet provides a 100% leakproof joint, yet future removal of the
counterflashing for inspection or repair of roofing material is possible.
Recommended gauges for counterflashing are .020" to .032" maximum for aluminum or zinc; 26 to 24 gauge for steel; 16
or 20 oz. for copper. Fast and easy installation of counterflashing can be made under all weather conditions.
Each order for type B4 Reglet is supplied with sufficient connector plugs and installation instructions with a full-size
template pattern for counterflashing.
Specifications
Specify Dayton Superior Type B4 Reglets and counterflashing in sheet metal section of specs. Sample specification: Use
Cushion-Lock Type B4 Reglet of PVC (polyvinyl chloride) plastic ASTM-D1784-81, Class 14333D, as manufactured by Dayton
Superior Corporation.
Connector Plugs
DS_ConnectorPlugs
Connector Plugs, made from flexible PVC 3" long are supplied with B4 Reglet.
They serve both to connect lengths of Reglet together, with adjoining openings
perfectly aligned, as well as a plug to keep concrete from entering reglet at ends.
Plugs may be easily removed to installation of counterflashing.
Installation
Counterflashing snaps and locks in position. Fastener is concealed and protected
by counterflashing. DO NOT rivet or fasten ends of counterflashing
together.
A. Reglet is fastened to form at 12" O.C. with 6 or 8 penny doubleheaded nail.
B. Concave design provides spring-like action to hold reglet tightly
against form lumber, when nail is driven home.
C. Reglet in position, after form is stripped, but prior to removal or
integral protective strip.
D. Lip acts as waterstop to prevent any possible water seepage
behind reglet.
Miscellaneous
Products
148
11/12
Other Products
Insulation Fixings
DS_InsulationFixings
Insulation Fixings are specifically designed for attaching foam insulation plates or foam panels in insulated
wall applications. They are primarily used in marine dock construction. With its button head, wire mesh
stays firmly in place over the foam panel. Available in 1" to 4" heights, 1,250 per carton.
To Order:
Specify: (1) quantity, (2) name, (3) height.
Example:
2 cartons, insulation fixing, 4" height.
PFA Insulation
Fixings
DS_T68ACA1000
T68 ACA 1000 is a specially designed, high strength, fast-tack contact spray adhesive to bond:
Concrete
Wood
Metal
MDF
Plastic
General Purpose
Reveal/Rustication Strips
Chamfer
Blockouts
Etc.
To Order:
Specify: (1) quantity, (2) name.
Example:
Miscellaneous
Products
11/12
149
Magnets
P153 Magnetic Steel Chamfer and Reveal DS_P153
Dayton Superior offers a variety of shapes of P153 Magnetic Steel Chamfers and Reveals. All offer unlimited reuses. The
magnets are embedded in the steel and sealed with an epoxy material to insure no damage form concrete or maximum reuse.
Chamfers are typically 1/2" x 1/2", 3/4" x 3/4", and 1" x 1". Reveals can be made to fit most requirements. Many of these
products are available in rigid plastic that offers a lower expense to the precaster but a smaller reuse factor. A flexible
3/4"x3/4" rubber chamfer is available when radius precast shapes are encountered.
P154 On/Off Magnets, Cam Magnets, Button, Loaf Magnets and Accessories
DS_P154
Dayton Superior has a wide variety of magnets for use in precast forms.
ON/OFF MAGNETS
CAM MAGNETS
Magnet is always on but easy to release from steel using built in cam release arm
Magnet attraction along sides and bottom
Available in different styles: Flat, Floating, Hole-Former, Notch
Strong adhesion and shear capacity for small magnet, up to 1000# adhesion
Cam Magnet
BUTTON MAGNETS
1 Ton and 2.5 Ton Adhesion Capacities standard other sizes available
Easy push down button engages magnet & easy release from steel,
using butt and release tool
Attachment to forms brackets available
Release tool available to reduce labor
LOAF MAGNETS
Size available for flat walls for 12", 16" & 24" steps
Step pins available for all step manufacturer's products
Separate tool used to remove step pin assembly from concrete
Eliminates the need to drill holes in core for step pins
Sizes available to fit into any size block-out, hole former or mandrel
Different magnetic holding strengths available
Eliminates the need to drill opening in concrete after it has been cast
BOOT GASKETS
Loaf Magnet
Miscellaneous
Products
150
11/12
Index
7.5 T Disposable Void Former.................. 78
ACA 1000............................................ 149
Accubrace Total Bracing System.......... 135
B1............................................................. 81
B2............................................................. 81
B11........................................................... 82
B12........................................................... 82
B13........................................................... 82
B14........................................................... 83
B16........................................................... 84
B17........................................................... 84
B18........................................................... 85
B25........................................................... 82
B33........................................................... 86
Bar Chair................................................. 143
BarLock Coupler.................................... 114
Beam Bolster.......................................... 143
Bearing Strips......................................... 146
Braces..................................................... 135
Bridge Girder Forms............................... 139
Cap Plug................................................. 101
Castle Chair......................................... 141
Ceiling Hangers...................................... 147
Chamfers................................................ 138
Coil Bolt.................................................... 83
Coil Nut.................................................... 82
Coil Rod.................................................... 82
Coil Ties Used as Inserts........................... 81
Connecting Systems Nylon Threaded
Inserts................................................. 109
Connector Plugs..................................... 148
Construction Spray Adhesive................. 149
Continuous High Chair.......................... 143
Corewall Edge and Corner Details......... 120
Corewall Nut Type Slotted Insert........... 116
Corewall Nut Type Slotted Insert......... 117
Corewall Slotted Insert II...................... 119
Corewall Slotted Strap Anchor............ 118
Corewall Strap Anchor......................... 118
Corewall Strap Type Slotted Insert......... 116
Corewall Strap Type Slotted Insert...... 118
Corewall Threaded Strap Anchor........ 118
Countersunk Screw.................................. 37
Cushion-Lock Reglet............................ 148
D108A.................................................... 110
D410....................................................... 111
D487....................................................... 112
D490....................................................... 111
D491....................................................... 112
D492....................................................... 112
D493....................................................... 112
Delta Tie................................................. 123
Disposable Setting Plugs.......................... 75
Double Flared Coil Loop Insert..........84, 86
Double Flared Loop Insert....................... 86
Double Swivel Lifting Plate...................... 96
Double Tee Anchor................................... 78
Dowel Bar Splicer................................... 113
Ductile Embed Insert.............................. 103
Dur-O-Web........................................... 121
Edge Lifting Plate..................................... 97
Elastomeric............................................. 136
Elasto-Tex................................................ 136
End Pickup Inserts..............................92, 94
Expanded Coil Ferrule Inserts................. 104
11/12
Index
P37......................................................... 129
P38......................................................... 119
P49........................................................... 82
P50........................................................... 17
P51........................................................... 19
P52.....................................................22, 25
P52W........................................................ 25
P53........................................................... 32
P54........................................................... 34
P56.....................................................23, 35
P56PL..................................................23, 36
P56R......................................................... 35
P57........................................................... 36
P58........................................................... 36
P59........................................................... 26
P60........................................................... 33
P61........................................................... 37
P62........................................................... 37
P63........................................................... 37
P63PL........................................................ 37
P64........................................................... 37
P64PL........................................................ 37
P66........................................................... 38
P66PL........................................................ 38
P67PL........................................................ 38
P68PL........................................................ 38
P69........................................................... 38
P75........................................................... 74
P75C......................................................... 74
P75H......................................................... 74
P76.....................................................75, 78
P76C......................................................... 75
P76D...................................................75, 78
P76M........................................................ 76
P77........................................................... 78
P80......................................................... 145
P81......................................................... 145
P82......................................................... 146
P83......................................................... 146
P84......................................................... 146
P87......................................................... 108
P88......................................................... 108
P90......................................................... 109
P91NC...................................................... 41
P91S......................................................... 40
P92.....................................................42, 54
P92AH...................................................... 55
P92DP....................................................... 46
P92FE........................................................ 48
P92FEW.................................................... 49
P92FEWDP................................................ 50
P92H......................................................... 51
P92HP....................................................... 51
P92P......................................................... 44
P92S......................................................... 53
P92SP....................................................... 53
P93........................................................... 56
P94H......................................................... 57
P94S......................................................... 58
P95F.......................................................... 58
P95P......................................................... 59
P96........................................................... 59
P96F.......................................................... 60
P98S......................................................... 61
P98T......................................................... 61
P99........................................................... 62
P99C......................................................... 64
P99D......................................................... 66
P99P......................................................... 70
P100...................................................62, 76
P100M...................................................... 71
P100MS.................................................... 71
P101...................................................62, 76
P104...................................................38, 76
P110......................................................... 79
P153....................................................... 150
P154....................................................... 150
Panel Pads.............................................. 142
Pile Forms............................................... 139
Pipe Brace Extensions............................ 132
Plain Ferrule............................................ 100
Plastic Setting Bolt................................... 93
PLW........................................................ 140
Post Forms.............................................. 139
Precast Sandwich Panel Tie.................... 129
Precast Wall Braces................................ 132
Prestress Strand Restraining Devices..... 131
PSBU....................................................... 142
PSW........................................................ 140
Recess Plugs............................................. 23
Rocket/Kohler Ferrule Insert................. 102
Round Cut Washer for Shelf Angle
Inserts............................................. 115
Round Void Hold Down......................... 144
Rustications............................................ 138
Rustication Strips................................... 137
Safety......................................................... 1
Setting Screw........................................... 71
Shimming Washers for Shelf Angle
Inserts...............................................115
Shimpak................................................. 145
Shim Strips............................................. 145
Single Flared Coil Loop Insert.................. 85
Single Pickup Insert.................................. 91
Slab Bolster....................................142, 143
Sleeve-Lock " SCH40 PVC.................. 112
Sleeve-Lock Form Plug......................... 112
Sleeve-Lock Grout................................ 111
Sleeve-Lock Grout Sleeve..................... 111
Sleeve-Lock Port Plug........................... 112
Sleeve-Lock Seal Plug........................... 112
Space Wheel....................................... 140
Star Adapter Plug................................... 108
Star Holzin Insert.................................. 108
Straight Coil Loop Insert.......................... 84
Strongback SBU.................................. 142
Superior Lift System................................. 60
Swift Lift................................................. 17
Swift Lift Anchor..............................22, 25
Swift Lift Anchors for Edge Lifting.......... 25
Swift Lift Eye Anchor............................. 32
Swift Lift Lifting Eye............................... 19
Swift Lift Magnetic Setting Plate........... 38
Swift Lift Narrow Recess Plug................ 35
Swift Lift Plus Holding Plate................... 38
Swift Lift Plus Holding Stud................... 37
Swift Lift Plus Recess Plug...................... 36
Swift Lift Plus Stud Plate........................ 38
Swift Lift Plus Threaded Plate................ 38
Swift Lift Plus Wing Nut........................... 37
11/12
11/12
11/12
Safety Information
Dayton Superior products are intended for use by trained, qualified and experienced workers only. Misuse or lack of supervision and/or inspection
can contribute to serious accidents or deaths. Any application other than those shown in this publication should be carefully tested before use.
The user of Dayton Superior products must evaluate the product application, determine the safe working load and control all field conditions to prevent applications of loads in excess of a products safe working load. Safety factors shown in this publication are approximate
minimum values. The data used to develop safe working loads for products displayed in this publication are a combination of actual
testing and/or other industry sources. Recommended safe working loads given for the products in this publication must never be exceeded.
For safety, concrete accessories must be properly used and maintained. Concrete accessories shown in this publication may be subject
to wear, overloading, corrosion, deformation, intentional alteration and other factors that may affect the devices performance. All
reusable accessories must be inspected regularly by the user to determine if they may be used at the rated safe working load or should
be removed from service. The frequency of inspections depends upon factors such as (but not limited to) the amount of use, period of
service and environment. It is the responsibility of the user to schedule accessory hardware inspections for wear and remove the hardware from service when wear is noted.
Welding can compromise a products safe working load value and cause hazardous situations. Knowledge of materials, heat treating and welding
procedures is necessary for proper welding. Consult a local welding supply dealer for assistance in determining required welding procedures.
Since Dayton Superior cannot control workmanship or conditions in which modifications are done, Dayton Superior cannot be responsible for any
product altered in the field.
Interchangeability
Many concrete accessory products that Dayton Superior manufactures are designed as part of a system. Dayton Superior strongly discourages efforts to interchange products supplied by other manufacturers with components supplied by Dayton Superior. When used
properly, and in accordance with published instructions, Dayton Superior products have proven to be among the best designed and
safest in the industry. Used improperly or with incompatible components supplied by other manufacturers, Dayton Superior products or
systems may be rendered unsafe.
Installation
WARNING
1. Dayton Superior Corporatin products shall be installed and used only as indicated on the Dayton Superior Corporation installation
guidelines and training materials.
2. Dayton Superior Corporation products must never be used for a purpose other than the purpose for which they were designed or in a
manner that exceeds specific load ratings.
3. All instructions are to be completely followed to ensure proper and safe installation and performance
4. Any improper misuse, misapplication, installation, or other failure to follow Dayton Superior Corporations instruction may cause product malfunction, property damage, srious bodily injury and death.
THE CUSTOMER IS RESPONSIBLE FOR THE FOLLOWING:
1. Conformance to all governing codes
2. Use of appropriate industry standard hardware
3. The integrity of structures to which the products are attached, including their capability to safely accept the loads imposed, as evaluated by a qualified engineer.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment
Design Changes
Dayton Superior reserves the right to change product designs, rated loads and product dimensions at any time without prior notice.
Note: See Safety Notes and Safety Factor Information.
Construction Chemicals
Forming Products
Unitex
Symons
Max-A-Form
Steel-Ply
Sym-Ply
Chemicals
Bond Breakers
Cleaners / Strippers
Concrete Repair/Restoration
Curing Compounds / Sealers
Epoxies
Floor Levelers
Form Release Agents
Grout
Hardeners / Industrial Toppings
Liquid Densifiers
Surface Retarders
FORMLINERS
REBAR SPLICING
ABS Plastic
Polystyrene Plastic
Precision Cut Foam
Solid Urethane
Urethane-Skinned Foam
PAVING
REBAR SUPPORTS
Concrete Dobies
Continuous Plastic and Steel
Bar Supports
Individual Plastic and Steel
Bar Supports
Mesh Chairs
Paving Chairs
Side Form Spacers
PRECAST
TILT-UP
Contact Information
Corporate Headquarters
1125 Byers Road
Miamisburg, OH 45342
937-866-0711
Forming Products
With products proudly made in America and a wide breadth of recognized brands, Dayton Superior is
the most comprehensive, single-source provider for all your concrete construction needs.
DS5
12/12
$9.95
W W W . D A Y T O N S U P E R I O R . C O M
B U I L D I N G
S T R E N G T H