PRECAST CONCRETE

Inserts, Connectors, Anchors and Lift Systems

Dayton Superior offers one of the most


comprehensive lines of precasting products in
the concrete industry, establishing the company
as the industrys preferred single-source provider.
The companys engineered, technologically
advanced precasting product solutions can be
found in many precast plants nationwide.

DAYTONSUPERIOR.COM

HANDBOOK

11/12

Fleet Lift System..................... 39

Fleet-Lift System Overview............... 39


P91S Fleet-Lift Ring Clutch1S............. 40
Installation of P91S Ring Clutch......... 40
P91NC Fleet-Lift Cable Bail Ring
Clutch.......................................... 41
Inspection and Maintenance of Ring
Clutches.......................................... 41
Additional Inspection of Cable Bails... 41
P92 Fleet-Lift Erection Anchor................
P92 Fleet-Lift Erection Anchor Tension
and Shear Capacities....................... 43
P92P Fleet-Lift Erection Anchor with
Shear Plate...................................... 44
P92P Fleet-Lift Erection Anchor with
Shear Plate Capacities..................... 45
P92DP Fleet-Lift Erection Anchor with
Shear Plate and Shear Pin............... 46
P92DP Fleet-Lift Erection Anchor
with Shear Plate and Shear Pin
Capacities...................................47
P92FE Fleet Lift Forged Erection
Anchor........................................... .
48
P92FEW Fleet Lift Forged Erection
Anchor with Sheer Plate................. 49
P92FEWDP Forged Erection Anchor
with Shear Plate and Secondary Shear
Pin.................................................. 50

Utility Anchor Lifting System.... 73

Utility Anchor System......................... 73


Anchor Placement.............................. 73
P75 and P75H Utility Anchor............ 74
P75C Utility Anchor with Clip........... 74
P76 Utility Anchor Setting Plugs....... 75
P76D Disposable Setting Plugs........... 75
P76C Utility Anchor Cover/Patch......... 75
P76M Utility Anchor Magnetic Setting
Plate............................................... 76
P100 Utility Anchor Holding Plate.... 76

Fleet-Lift System

Swift Lift System

General and
Technical
Information
Utility Anchor
Lifting System
Lifting/Handling
Inserts
and Accessories
Structural
Connectors

Swift Lift System............................... 17


P50 Swift Lift Universal Lifting Eye... 17
P50 Inspection and Maintenance....... 17
Dos and Donts of the P50 Swift Lift
Universal Lifting Eye........................ 18
Inspection and Maintenance.............. 19
How to use the P51 Swift Lift Lifting
Eye................................................ 21
P52 Swift Lift Anchor........................ 22
P52 Swift Lift Anchor and Recess Plug
Dimensions..................................... 22
How to Install P56 and P56PL Recess
Plugs on P52 Anchors..................... 23
Wet Setting P52 Swift Lift Face Lift
Anchors.......................................... 23
Recess Plug Removal.......................... 23
Selecting the Proper Swift Lift
Anchor........................................23
P52 Swift Lift Anchor Tensile and Shear
Capacity.......................................... 24
P52W Swift Lift Anchor ................... 25
P52 Swift Lift Anchors for Edge Lifting... 25
P59 Swift Lift Shear Bar.................... 26
P59 Swift Lift Smooth Wire Shear Bar... 26
P52 Swift Lift Anchor in Thin Walls... 27
Swift Lift Anchor Effective Tensile
Capacity in Thin Walls..................... 27
Swift Lift Anchor Effective Tensile
Capacity in Thin Walls..................... 28

P92HP Fleet-Lift Two-Hole Erection


Anchor with Shear Plate................. 51
Shear Reinforcement.......................... 51
Tension Reinforcement....................... 51
P92H Fleet-Lift Two-Hole Erection
Anchor and P92HP Fleet-Lift TwoHole Erection Anchor with Shear
Plate Capacities............................... 52
P92S Fleet-Lift Sandwich Panel Erection
Anchor............................................ 53
P92SP Fleet-Lift Sandwich Panel
Erection Anchor with Shear Plate.... 53
P92 Fleet-LIft Sandwich Panel
Reinforcing Bars.............................. 54
P92AH Fleet-Lift Erection Anchor with
45 Head with Shear Plate.............. 55
P93 Fleet-Lift L-Anchor....................... 56
P94 Fleet-Lift T-Anchor....................... 56
P94H Fleet-Lift H-Anchor 2-Ton.......... 57
P94S Fleet-Lift S-Anchor 6-Ton........... 58
P95F Fleet-Lift Flat Foot Anchor.......... 58
P95P Fleet-Lift Plate Anchor............... 59
P96 Fleet-Lift TwoHole Anchor.......... 59
P96F Fleet-Lift Forged Two-Hole
Anchor.......................................... 60
T110 Superior Lift System.................. 60
P98S Fleet-Lift Shear Bar.................... 61
P98T Fleet-Lift Tension Bar.................. 61
P99 Fleet-Lift Reusable Recess Plug.... 62
P100 Fleet-Lift Holding Plate and P101
Fleet-Lift Holding Rod..................... 62
Installation and Removal of Anchors
and Reusable Recess Plugs.............. 63
P99C Fleet-Lift Cast Steel Recess Plug.64
Installation and Removal of the FleetLift Cast Steel Recess Plug............... 65
P99D Fleet-Lift Disposable Recess Plug
(PVC)............................................... 66
Installation of P99D Disposable Recess
Plug and Erection Anchors.............. 67
Installation of P99D Disposable Recess
Plug and Standard Anchors............ 68
P99D Temporary Cover/Patch
Installation...................................... 69
P99P Fleet Patch................................. 70
P100M Fleet-Lift Magnetic Plate......... 71
P100MS Setting Screw....................... 71
P100M Fleet-Lift Magnetic Plate
Installation...................................... 71
P104 Fleet Lift One Piece Magnetic
Recess............................................. 71

Miscellaneous
Connection Inserts

Swift Lift System...................... 17

Swift Lift Anchor Effective Tensile


Capacity.......................................... 30
Swift Lift Anchor Effective Tensile
Capacity.......................................... 31
P53 Swift Lift Eye Anchor................. 32
P53 Swift Lift Eye Anchor for Lifting
and Handling.................................. 32
P53 Swift Lift Eye Anchor Selection
Chart.............................................. 32
P60 Swift Lift Tension Bar................. 33
P60 Swift Lift Tension Bar
Installation.................................33
P54 Swift Lift Throw-Away Recess
Plug. ...........................................34
P56 Swift Lift Narrow Recess Plug......... 35
P56R Swift Lift Round Recess Plug.... 35
P56PL Swift Lift Plus Recess Plug...... 36
P57 Swift Lift Steel Recess Plug........ 36
P58 Swift Lift Rubber Ring................ 36
P61 Swift Lift Setting Plate, P62
Countersunk Screw......................... 37
P63 Swift Lift Stud, P64 Swift Lift
Wing Nut........................................ 37
P63PL Swift Lift Plus Holding Stud,
P64PL Swift Lift Plus Wing Nut....... 37
P66 Swift Lift Tapped Plate6............. 38
P66PL Swift Lift Plus Threaded Plate.38
P67PL Swift Lift Plus Stud Plate........ 38
P68PL Swift Lift Plus Holding Plate... 38
P69 Swift Lift Magnetic Setting
Plate...........................................38
P104 Magnetic OnePiece Swift Lift
Recess............................................. 38

Sandwich Panel
Connectors

Safety Notes and Product Application.. 1


Safety Factors....................................... 1
Factors Affecting the Load-Carrying
Capacity of an Insert......................... 2
The Mechanical Strength of the Insert. 2
The Strength of the Concrete............... 3
Safe Working Load Reduction Factors for
Inserts Used in Lightweight Concrete.... 4
Location of Insert................................. 4
Insert Placement................................... 5
Edge and Shear Loading...................... 6
Torque-Tension Relationship................. 7
NC Threaded Bolt Capacities................ 7
Condition of Loadings.......................... 7
Corrosion Protection............................ 8
ASTM Standards For Corrosion Resisting
Coatings........................................... 8
Condition of Loading........................... 9
Transverse and Shear Loading............ 10
Calculating Sling/Anchor Loads.......... 11
Rigging For Traveling Over Rough
Ground........................................... 11
Rigging............................................... 12
Selecting the Proper Insert................. 13
Coil Insert Safe Working Load Reduction
Factors For Free Edge Conditions
Tension Loadings Only...................... 15
How to Use Reduction Factors:.......... 15
Coil Insert Safe Working Load Reduction
Factors For Thin Wall Conditions
Tension Loadings Only...................... 16
How to Use Reduction Factors:.......... 16

Miscellaneous
Products

P92H Fleet-Lift Two-Hole Erection


Swift Lift Anchor Effective Tensile
General and Technical
Anchor............................................ 51
Capacity in Thin Walls..................... 29
Information.............................. 1

General and
Technical
Information
Swift Lift System

P101 Utility Anchor Holding Rod...... 76


P104 One Piece Magnetic Utility
Anchor Recess............................... 76
Anchor Placement.............................. 77
P77 Double Tee Anchor...................... 78
P76D 7.5 T Disposable Void Former.... 78
P76 Utility Anchor and Double Tee
Anchor Setting Plug........................ 78
P110 Wire Rope Lifting System........ 79

Threaded Inserts........................... 109


D108A Headed Dowel Bar Insert...... 110
D410 Sleeve-Lock Grout Sleeve....... 111
D490 Sleeve-Lock Grout................. 111
D487 Sleeve-Lock Seal Plug............ 112
D491 Sleeve-Lock Form Plug........... 112
D492 Sleeve-Lock " SCH40 PVC.... 112
D493 Sleeve-Lock Port Plug............ 112

Sleeve Lock Grout Sleeve....... 113

Lifting and Handling Inserts...... 81 Dowel Bar Splicer System................. 113

Fleet-Lift System
Utility Anchor
Lifting System
Lifting/Handling
Inserts
and Accessories
Structural
Connectors
Miscellaneous
Sandwich Panel
Connection Inserts
Connectors

B1 or B2 Coil Ties Used as Inserts....... 81


Mounting Washers............................. 81
B11 Flat Washer................................. 82
B12 and P49 Coil Rod......................... 82
B13 Coil Nut and B25 Heavy Coil Nut.82
B14 Coil Bolt...................................... 83
B16 Straight Coil Loop Insert.............. 84
B17 Double Flared Coil Loop Insert.... 84
B18 Single Flared Coil Loop Insert...... 85
B33 Double Flared Coil Loop Insert.... 86
F47 Double Flared Loop Insert............ 86
F48 Eye Nut, F49 Eye Bolt and F49A Eye
Bolt................................................. 87
P21 Wire Rope Loop........................... 88
F53 Thin Slab Coil Insert..................... 88
F56, F58 and F60 Expanded Coil Inserts...89
F63 Flared Thin Slab Coil Insert.......... 90
F65 Type L Coil Insert.......................... 90
T1 Single Pickup Insert....................... 91
T3 and T3A End Pickup Inserts........... 92
T7S and T7ST Slotted Setting Studs.... 93
P25 Plastic Setting Bolt....................... 93
T8 Lifting Angle.................................. 93
T10 and T11 End Pickup Inserts T10 or T11
End Pickup Insert Selection Chart........ 94
Proper Installation of T3 and T11 End
Pickup Inserts.................................. 95
How To Determine Bolt Length........... 95
T12 Swivel Lifting Plate...................... 96
T21 Insert Locator Plugs..................... 96
T26 Double Swivel Lifting Plate.......... 96
T27 Edge Lifting Plate........................ 97
Dos and Donts.................................. 97
Total System and Safe Working Loads.... 97

Dayton Superior BarLock Coupler


System.......................................... 114
F7 Hex Nut for Shelf Angle Inserts.... 115
F7 Round Cut Washer for Shelf Angle
Inserts........................................... 115
F9 Shimming Washers for Shelf Angle
Inserts........................................... 115
F11 Hanger Insert and F12 Hanger
Hook............................................. 115
P30 Corewall Nut Type Slotted
Insert...................................... 116
P31 Corewall Strap Type Slotted
Insert...................................... 116
P30 Corewall Nut Type Slotted
Insert...................................... 117
P31 Corewall Strap Type Slotted
Insert...................................... 118
P32 Corewall Strap Anchor............. 118
P33 Corewall Slotted Strap Anchor.118
P34 Corewall Threaded Strap
Anchor......................................118
P38 Corewall Slotted Insert II.......... 119
New Corewall Edge and Corner
Details......................................... 120
P12D Dur-O-Web Shear Reinforcement
DS_P12......................................... 121
P12D Dur-O-Web Shear
Reinforcement............................. 122

Miscellaneous Connection
Inserts..................................123

Thermoform Vacuum-Formed
Formliners..................................... 136
Rustication Strips............................. 137
Rustications, Chamfers and Coverers.... 138

Miscellaneous Products........... 139

P8A Architectural Post Forms........... 139


P8B Bridge Girder Forms.................. 139
P8M Median Barrier Forms............... 139
P8P Pile Forms.................................. 139
PLW EZ Lok Wheel...................... 140
PSW Space Wheel....................... 140
Tower Bar Chair................................ 141
Tower High Chair.............................. 141
E-Z Chair......................................... 141
Castle Chair................................... 141
X-Chair............................................. 142
E-Z LOK Slab Bolster...................... 142
PSBU Strongback SBU................... 142
Panel Pads........................................ 142
Slab Bolster...................................... 143
Beam Bolster.................................... 143
Continuous High Chair..................... 143
Individual High Chair........................ 143
Bar Chair.......................................... 143
Joist Chair........................................ 143
K50 Void Retention Insert................. 144
H13 Round Void Hold Down............ 144
P80 Shim Strips................................ 145
P81 Shimpak.................................... 145
P82 Bearing Strips Strips.................. 146
P83 Horseshoe Spacers..................... 146
P84 Korolath Core Plugs................... 146
F67, F68, and F69 Ceiling Hangers... 147
F75 Marble Facing Anchor............... 147
Cushion-Lock Reglet Type B4.......... 148
Connector Plugs............................... 148
Insulation Fixings............................. 149
T68 ACA 1000 Construction Spray
Adhesive....................................... 149
P153 Magnetic Steel Chamfer and
Reveal........................................... 150
P154 On/Off Magnets, Cam Magnets,
Button, Loaf Magnets and
Accessories................................... 150

Miscellaneous
Products

P24 Delta Tie.................................... 123


P24 Delta Tie.................................... 124
P24 Delta Tie Design Chart............... 125
P24 Delta Tie Insulated Panel
Installation Sequence.................... 126 Index........................................ 151
NC Threaded Inserts.................. 99
F5 Threaded Insert............................. 99 P12G Welded Wire Girders............... 127
F42 Loop Ferrule Insert....................... 99 P14 Type L Connector Pin................. 128
F43 Plain Ferrule............................... 100 and P15 Type M Connector Pin......... 128
Special Ferrule Application............... 100 P9 Precast Sandwich Panel Tie.......... 129
F44 Thin Slab Ferrule Insert.............. 101 P37 M Anchor Shear Connector.... 129
F45 Cap Plug.................................... 101 Sandwich Panel Connectors.... 131
F50 Rocket/Kohler Ferrule Insert..... 102 Prestress Strand Restraining Devices.131
F52 Thin Slab Ferrule Insert.............. 102 T14 Precast Wall Braces.................... 132
F54 Ductile Embed Insert................. 103 T15 Pipe Brace Extensions................ 132
F57 Expanded Coil Ferrule Insert...... 104 Brace Loading.................................. 133
F59 Expanded Coil Ferrule Insert...... 104 Bracing to Cylindrical Deadman.............
F61 Expanded Coil Ferrule Insert...... 104
DS_CylindricalDeadman................ 134
F62 Flared Thin Slab Ferrule Inser..... 105 Brace Maintenance........................... 134
F64 Ferrule Loop Insert..................... 106 Accubrace Total Bracing System..... 135
F72 Threaded Setting Plug............... 107 Elasto-Tex High Re-Use Elastomeric
F74 Threaded Plastic Plug................. 107
Formliner ..................................... 136
P87 Star Adapter Plug...................... 108 Vinyltite Trapezoidal Interlocking

P88 Star Holzin Insert..................... 108


Formliners..................................... 136
P90 Connecting Systems Nylon

11/12

Safety Notes and Product Application


In the continuous development of hardware for the precast industry, Dayton Superior places great emphasis on ensuring
that material supplied from its manufacturing plants meets or exceeds safety requirements for lifting, handling and
connecting precast concrete elements. Dayton Superior and/or independent testing laboratories have conducted tests on
products shown in this handbook. The safe working loads listed were determined from these tests and were established
with the following factors in mind:
1. All safe working loads shown are based on the item being new or in as new condition.
2. No loads greater than the products safe working load.
3. All inserts properly embedded and firmly fixed in place in sound, normal weight concrete so that the vertical axis of the
insert is perpendicular to the lifting surface.
4. All bolted hardware has full bearing on the concrete surface and all attachment bolts bear fully on the hardware. Do
not subject hardware to side loading that will cause additional and unintended loading.
5. Erection and attachment bolts are of proper length and are well tightened to prevent hardware slippage and bolt bending.
6. Coil bolts have at least the specified minimum penetration through the insert coil, but do not bear on concrete at the
bottom of the void.
7. Concrete compressive strength (fc) at time of initial use is at least the strength listed in the appropriate insert selection chart.
8. Inserts are properly located in relation to edges, corners and openings and at a proper distance to permit the
development of a full concrete shear cone. Refer to the minimum edge distances shown in the appropriate insert
selection chart.
9. Tensile load on the insert has been calculated, including the effect of both axial and transverse loads, as transmitted by
the crane lines to the hardware.
10. No impact wrenches will be used to tighten bolts used for lifting, handling, transporting, connecting or bracing.
11. All zinc plated medium-high carbon, or high carbon steel items have been properly baked to relieve embrittlement.
Not doing so may result in premature failure.
12. There has been no welding on any portion of an insert or to lifting hardware units after they have left a Dayton
Superior manufacturing plant. Welding may cause embrittlement, which can result in a premature failure. Welding
requires a good working knowledge of materials, heat treatment and welding procedures. Since Dayton Superior
cannot control field conditions or workmanship, Dayton Superior DOES NOT GUARANTEE any product altered in any
way after leaving the factory.

Safety Factors
A safety factor applied to a particular product is a variable, depending on the degree of hazard or risk involved in the application
of that product. In precast concrete construction various conditions can often increase loading, as well as the degree of risk
involved. Adhesion of the concrete element to the form, jerking of the crane during lifting, use of a crane not adequate for the
job, bouncing the precast element after it has been lifted, handling the element more than anticipated, transporting over rough
surfaces, etc., all have high risk factors. In cases such as these, the user should increase the safety factor accordingly.
Dayton Superior recommends that the following minimum safety factors be used when determining a products safe
working load and that the provisions of OSHA (Occupational Safety and Health Administration Act, Part 1910) be strictly
followed when considering safety factors:
If a different safety factor from one shown in this handbook is required for any reason, the following equation is used to
increase or reduce a safe working load:
Safety Factor
2 to 1

Brace Anchors

3 to 1

Permanent Connections

4 to 1

Inserts used for lifting and handling

5 to 1

Hardware used for lifting and handling

New Safe Working Load =

Intended Use of Product

Old Safe Working Load x Old Safety Factor


New Safety Factor

Warning: New safe working load must not exceed the products mechanical capacity divided by the new safety factor.

11/12

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


USERS OF DAYTON SUPERIOR PRODUCTS MUST EVALUATE THE PRODUCT APPLICATION,
CALCULATE INDUCED LOADS, DETERMINE NECESSARY SAFETY FACTORS, CALCULATE SAFE
WORKING LOADS AND CONTROL ALL FIELD CONDITIONS TO PREVENT APPLICATION OF LOADS
IN EXCESS OF THE SAFE WORKING LOAD.

Factors Affecting the Load-Carrying Capacity of an Insert


Attachment Bolt and Hardware Considerations:
The selection of an attachment bolt diameter will depend upon the job the bolt is required to do. If, for instance, bolts are
to be used repeatedly and are subject to tension and shear, choose a bolt at least one size larger in diameter than static
loading conditions would require. Since coil bolts are not intended for bending loads, care must be taken to be sure that
the bolts are properly tightened.
Bolt failures are generally caused by excessive thread wear, field modification, or bending and/or straightening of bolts. It
is the responsibility of the user to continually inspect bolts and working hardware for wear and discard the parts when
wear is noted. Do not straighten bent bolts, discard and replace them. Also, any bolts known to have been used at loads
of 70%, or more, of ultimate strength should be removed from service and discarded. Such bolts may have been stretched
sufficiently to become brittle-hard and could lead to premature failure of the bolts. Every user must establish a control
program to replace attachment bolts after a predetermined number of uses, regardless of their appearance.
Lifting hardware shown in this handbook is subject to wear, misuse, overloading, corrosion, deformation, intentional
alteration and other factors that could affect the hardwares safe working load. Therefore, the user must inspect the
condition of the hardware units regularly to determine if they can be used at their rated safe working load. If not, they
must be removed from service. The frequency of inspection is best determined by the user and is dependent upon factors
such as frequency of use, period of use and environmental conditions.

The Mechanical Strength of the Insert


Lifting inserts/anchors displayed in this handbook are fabricated from carbon steel that has sufficient strength to safely
carry the specified safe working loads. Many of the inserts/anchors herein can be special ordered, fabricated from stainless
steel material. When an insert is fabricated from stainless steel, it may have a lower safe working load than the safe
working load published for the corresponding carbon steel insert. Contact a Dayton Superior Technical Services Department
for safe working loads of inserts fabricated from stainless steel.

11/12

The Strength of the Concrete


When a load is applied to an insert embedded in concrete, it induces a corresponding resistive force in the concrete. Insert
failures can be predicted with a reasonable degree of accuracy by using the following equation for concrete breakout from
ACI 318 Appendix D.
f'c = Compressive strength of the concrete at time of lift
Tension Safe Working Load = jc,N x l x 24 x f'c x hef1.5

Appropriate Safety Factor

l
= Reduction factor for use with lightweight concrete, see "Safe Working Load Reduction Factors for Inserts Used in
Lightweight Concrete" next page;
jc,N

= Factor for cracked concrete: 1.0 if cracked and 1.25 if uncracked.


Pconcrete

Surface
Area of
Theoretical
Shear Cone

Concrete
Surface

hef
35

dh

Pconcrete

Illustration A1
For inserts located near an edge
preventing development of a
full shear cone please contact
a Dayton Superior Technical
Services Department for insert
capabilities.

Surface Area
of Theoretical
Shear Cone

Concrete
Surface

hef

Warning! Adding rebar to the


horizontal portion of an insert will
reduce the depth of the shear cone
(l ), resulting in a reduced insert
capacity. When rebar are added
for insert stability, they should be
placed against the vertical portion
of the insert and at least 1" away
from the horizontal portion.
e

35

dh

Illustration A2
When the value of Pconcrete exceeds the ultimate mechanical tensile capacity of the insert, the insert will fail. It is apparent
that the shear cone becomes larger as the insert is embedded deeper in the concrete. Sufficient depth of embedment
would theoretically permit the development of the full ultimate strength of the insert.
Deep embedment is generally considered impractical for precast concrete, but some types of anchors depend upon this
principle for their effectiveness. The Dayton Superior F1 Screw Anchor and P52 Swift Lift Anchor are two examples.
All other factors being equal, depth of embedment has more effect on the strength of a concrete insert than any other
single factor. A concrete insert under tensile loading to failure will fail in one of four ways:
1. The entire insert may pull out of the concrete with little apparent damage to the concrete (see Illustration B). Such failures
are rare and, when they do occur, are the result of bond failure between the concrete and insert. These failures usually
occur in green and/or low strength concrete.
2. The entire insert may pull out of the concrete bringing with it a cone of concrete having its apex slightly above the most
deeply embedded part of the insert (see Illustration C). Such failures usually occur in relatively low strength concrete in
which the tensile strength of the shear cone surrounding the insert is not as great as the strength of the insert itself.
3. A failure may also occur through breakage of the insert. Coil type inserts will usually fail at a point just below the helically
wound wire coil. A small cone of concrete will usually be pulled out of the concrete surface (see Illustration D). This cone
will have its apex at a point just below the coil. The base diameter will be approximately twice the cone height. Swift Lift
Inserts will fail by fracturing of the shaft diameter of the insert (see Illustration E).

NOTE: The above formulas have been applied to all coil and ferrule insert charts in this handbook. All manufactured
lifting systems (Swift Lift, Fleet Lift, Utility Anchor) utilize test results.
These failures occur in high strength concrete when an insert is loaded beyond the ultimate strength of the insert. Failures
of this type are due to a definite overload being applied to the inserts. Such failures can be prevented by choosing inserts
of capacity suitable to job conditions.

11/12

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information

4. When bolting coil type inserts, the bolt should always extend the proper amount beyond the bottom of the insert coil.
Failure to do this causes the entire bolt load to be transferred to fewer turns of the coil, causing an increased load per
weld contact point. The coil will then unwind, much like a corkscrew, resulting in a failure (see Illustration F).

P
P
P

Illustration B

Illustration C

Illustration D

Illustration E

Illustration F

Safe Working Load Reduction Factors for Inserts Used in Lightweight Concrete
Insert safe working loads, shown in this handbook, were derived from analysis and testing of Dayton Superior inserts
used in normal weight (150 pcf) concrete. The safe working load of the insert is dependent upon the compressive
strength of the concrete in which it is embedded. Therefore, when Dayton Superior inserts are used in lightweight
concrete precast elements, the safe working load of the inserts must be recalculated to compensate for the reduction
in concrete density. Multiply the published safe working loads by a reduction factor, shown in the table, to obtain the
corrected safe working load. The table displays the various reduction factors recommended by Dayton Superior for
lightweight concrete.
Concrete Type

Safe Working Load Reduction Factor

Normal Weight

1.0

Sand and Lightweight Aggregates

0.85

All Lightweight Materials with a Weight of 110 PCF or more

0.75

All Lightweight Materials with a Weight of 110 PCF or less

Verify by Testing

Interested readers are referred to Section 11.2 of the American Concrete Institutes Building Code Requirements for Reinforced Concrete (ACI 318) for additional information.

Location of Insert
Embedment of inserts closer to an edge than the minimum edge distances, shown in this handbook, will greatly reduce
the effective area of the resisting concrete shear cone and will reduce the inserts tension safe working load. The shaded

11/12

area of the shear cone, shown in the illustrations below, indicates the extent the shear cone area is reduced. Tension
safe working loads of inserts used in thin wall conditions or near a free edge or corner must, therefore, be reduced in
proportion to the reduction in effective shear cone area (see Illustrations G & H).
Another condition frequently encountered is that of an insert embedded near a free edge or corner and loaded in a
transverse direction to the axis of the bolt, toward the free edge of the concrete. Contact Dayton Superior Technical
Assistance for safe working loads of inserts used in this type of condition.
P
Tension
or P
Shear

P
D

de

D = Insert Minimum Edge Distance

de

Required to Develop Inserts Safe Working Load

de = Actual Edge Distance

Illustration G

Illustration H

Insert Placement
Inserts must be placed accurately. An inserts safe working load decreases sharply if it is not perpendicular to the bearing
surface, or if it is not in line with the applied force.
Inserts lend themselves to being located and held correctly (by bolts and brackets or by tying to the reinforcing steel)
before the casting operation begins. Failure to achieve proper insert placement is careless field installation. It is also
important to place inserts so that the depth of thread is constant for the same size insert throughout a job. This eliminates
potential bolt engagement mistakes by the erection crew. Inserts should always be kept clean of dirt, ice or other objects
that will interfere with attachment of the lifting hardware.
Note: For ferrule inserts, establish this dimension and
maintain for all similar sized inserts on a project. For coil
inserts, the coil bolt must penetrate through the insert coil
by the proper amount.

1/2"
Minimum
to Develop
Insert Safe
Working
Load

90

Wrong

(Too High)

Wrong

Wrong
(Angled)

(Too Low)

Correct

Illustration I

11/12

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


Edge and Shear Loading
Another condition frequently encountered is an insert embedded near a free edge or corner and loaded in a direction
transverse to the axis of the bolt, toward the free edge. Edge lift panels are examples of this condition.
Many tests have shown that edge inserts loaded transversely to destruction (see Illustration L) finally fail because of an
initial failure of the concrete over the coil. This initial failure transfers the entire load to the insert struts. If the load is large
enough, the struts will fail in bending or shear or both.
An analysis of tests indicates that the ultimate load on edge inserts loaded in the direction of the free edge is a function
of the distance from the insert to the free edge. The effect of bolt diameter and insert configuration appears to be of
secondary and negligible importance. For conditions where shear loading must be considered, it is appropriate to use the
following equation from ACI 318 Appendix D:
0.2

Shear Safe Working Load (lbs.) =

1e
1.5

c7
nd o nd o fc (c al)

Appropriate Safety Factor


With the maximum shear safe working load equal to, or less than, the inserts tension Safe Working Load.
Where:
jc

= Cracked concrete factor: 1.0 for cracked concrete and 1.4 if uncracked.

= Reduction factor for lightweight concrete, see page 6.

l e

= Minimum of embedment length or 8 x (n x do).

= Number of struts on the insert.

do

= Diameter of the insert struts.

fc

= Specified concrete compressive strength.

ca1

= Distance from centerline of the insert to the edge.

For conditions where a corner or thickness in direction of embedment is less than 1.5 x ca1 or an adjacent insert is closer
than 3 x ca1 contact Dayton Superior Technical Services Department for insert capacities.
For cases where increased shear capacity is required, the addition of pre-formed shear bars over the top of the insert will
greatly increase the distribution of the load. Shear bars, when used, must be in solid contact with the insert to be effective.
If accurate capacities of inserts are desired, several inserts with shear bars should be tested in job size panels.
ca1

P
Point X
Point X
Shaded areas indicate probable tensile stress pattern in
concrete near edge insert subject to load P.

Illustration L

Dotted line indicates line of probable concrete failure Point


X point of possible strut fracture.

Combined Shear and Tension


Inserts and bolts that are subjected to combined shear and tension loadings should satisfy the following equation:

( fF ) / ( fF ) /
5

3 +

1.0

Where:
fv

= Applied shear load;

Fv

= Shear safe working load;

ft

= Applied tension load;

Ft

= Tension safe working load.

11/12

Torque-Tension Relationship
For some types of bolted connections, it may be desirable to have a minimum clamping force (tension load). Due to the
many variables associated with tightening bolted connections, it is possible to experience as much as a 25% variation in
the amount of clamping force applied to similar connections receiving identical torque.
The following equation is taken from Fasteners Standards Sixth Edition, published by Industrial Fasteners Institute, East
Ohio Building, 1717 East 9th Street, Suite 1105, Cleveland, Ohio 44114-2879. It is used to provide an estimate of the
torque required to apply a given preload to a bolted connection.
T = KDP
12

Where: T = Torque (ft.lbs.);



K = Torque coefficient;

D = Nominal bolt diameter;

P = Tension in bolt (Ibs.)
The torque coefficient is the critical factor in the above formula. It is best to experimentally determine K for
critical applications using actual connection materials and assembly tools.
Arbitrary values for K are often assigned in non-critical applications, as follows:

K = .20 for NC threaded bolts per Fasteners Standards Sixth Edition


K = .30 for Coil threaded bolts per test results.

The torque coefficient will vary from the values, shown above, when bolts have been plated, greased or coated with other
types of lubricant.

NC Threaded Bolt Capacities


Permanent connections in precast construction are normally made with either ferrule inserts or slotted inserts using
National Course (NC) threaded bolts. NC threaded bolts are normally not supplied by Dayton Superior. However, as a
convenience to the precast designer, the following chart is listed.
NC Threaded Bolt Selection Chart
Nominal Bolt
Diameter and
Threads per Inch

ASTM A-307 Bolts

ASTM A-325 or A-449 Bolts

Tension

Shear

Tension

Shear

1/4" 20

625 lbs.

350 lbs.

1,250 lbs.

725 lbs.

3/8" 16

1,500 lbs.

900 lbs.

3,100 lbs.

1,800 lbs.

1/2" 13

2,800 lbs.

1,700 lbs.

5,600 lbs.

3,400 lbs.

5/8" 11

4,500 lbs.

2,700 lbs.

9,000 lbs.

5,400 lbs.

3/4" 10

6,600 lbs.

4,000 lbs.

13,300 lbs.

8,100 lbs.

7/8" 9

9,200 lbs.

5,600 lbs.

18,400 lbs.

11,300 lbs.

1" 8

12,100 lbs.

7,400 lbs.

24,200 lbs.

14,900 lbs.

1-1/8" 7

15,200 lbs.

9,400 lbs.

26,700 lbs.

16,400 lbs.

1-1/4" 7

19,300 lbs.

12,000 lbs.

33,900 lbs.

21,000 lbs.

1-1/2" 6

28,100 lbs.

17,500 lbs.

49,100 lbs.

30,600 lbs.

Safe working loads shown provide a factor of safety of approximately 3 to 1 (ultimate to Safe Working Load). Shear
Safe Working Load assumes that the threads are included in the shear plane. 1/4"20, 3/8"16 and 1/2"13 bolts are not
recommended for use as structural fasteners. For combined shear/tension interaction, refer to page 12.

Condition of Loadings
All safe working loads shown in this handbook are for static load conditions only. If dynamic forces or impact loading
conditions are anticipated, the safe working load must be reduced accordingly.
Care must be exercised to see that all inserts and hardware units are properly aligned, all lifting plates and bolts properly
secured, all rigging is equalized, and properly sized crane cables utilized.
Warning: When in doubt about the proper use or installation of a Dayton Superior precast product, contact Dayton
Superior for clarification. Failure to do so may result in safety hazards, exposing workers in the vicinity of the precast yard
or job site to the possibility of injury or death.

11/12

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


Corrosion Protection
The Dayton Superior precast products shown in this handbook are available in several different finishes or coatings. These
finishes vary in the degree of corrosion protection provided. Standard finish is PLAIN and will normally be furnished if no
finish is specified. Finishes available are as follows:
PLAIN or unfinished steel is sometimes referred to as BLACK or RAW. PLAIN finished material will rust when exposed to the
environment.
ELECTRO-GALVANIZED finish is a zinc plated finish that provides a varying degree of corrosion protection depending on the
thickness of the zinc plating and type of after-plating coating specified. This finish is recommended for threaded products.
DaytonSuperior electro-galvanizing conforms to ASTM Standard B-633, Service Condition 1 as plated. Other options
available underthis ASTM Standard are listed below.
HOT DIPPED GALVANIZED or HDG products are zinc coated by the hot-dipped process and will provide better corrosion
protection than electro-galvanized finished products due to the thicker HDG zinc coating. This finish is not recommended
for threaded products due to potential assembly problems. Dayton Superior hot dipped galvanizing conforms to ASTM
A-123 or A-153.
EPOXY-POLYESTER or EPOXY finish is a dielectric material that is used to provide corrosion protection for steel products
that are to be embedded in precast concrete. This material is usually applied to a coating thickness between 5 and 12
mils. Epoxy-Polyester finish is normally specified when an affordable solution to salt spray corrosion is required. Not
recommended for use where threads are to be coated. STAINLESS STEEL is recommended for its excellent corrosion
protection that will resist ordinary rusting. Type 304 Stainless Steel is recommended for use in precast products. It is the
most economical type of stainless steel available for its level of corrosion resistance. Note that Type 304 Stainless Steel will
rust when exposed to certain chemicals used to acid wash the surface of architectural precast concrete.

ASTM Standards For Corrosion Resisting Coatings


ASTM A-123 Zinc (Hot Dipped Galvanized) Coating on Iron or Steel
Product Type

Material

Approximate Thickness

Wire

.142" to .186" diameter

.002"

Wire

.187" to .249" diameter

.003"

Wire

.250" diameter or larger

.004"

Steel or Plate

.030" to .062" thick

.002"

Steel or Plate

.063" to .124" thick

.003"

Steel or Plate

.125" or thicker

.004"

ASTM A-153 Zinc Coatings (Hot Dip) on Iron or Steel Hardware


Product Type

Class

Approximate Thickness

Castings

.004"

Steel, 3/16" and thicker

B1

.004"

Steel, 3/16" and thinner

B2

.003"

ASTM B-633 Electro Deposited Coatings of Zinc on Iron and Steel


Service Condition

Exposure

SC-4

Very Severe

.001"

SC-3

Severe

.0005"

SC-2

Moderate

.0003"

SC-1

Mild

.0002"

Approximate Thickness

ASTM B-633 Continued


Type

After Plating Coating

As Plated

Colored Chromate

Colorless Chromate

Phosphate

Note: Electro-galvanized or hot dipped


galvanized items fabricated from
medium high carbon or high carbon
steel must be properly treated to minimize hydrogen embrittlement. Failure to
properly bake these items may result in
a drastic reduction in their safe working
load and premature failure resulting in
property damage, injuries or death.

11/12

Condition of Loading
The preceding paragraphs have been devoted to the behavior of concrete inserts under straight tensile loading. Obviously,
there are many conditions of loading other than direct tension. Most situations will require consideration of shearing
and/or bending forces applied to the insert through the anchor bolt or other connecting hardware. A common condition
occurs when a precast concrete element is lifted by means of inserts in each end without a spreader bar (see IllustrationJ).
When a load P is carried by only two inserts, the vertical reaction R that must be carried by each insert is 1/2 P. There is
also an additional vertical force V, that must be added to R, that is caused by the horizontal component H of force T.
The horizontal force H that is exerted on the insert and on the concrete surrounding it is proportional to the total load and
to the angle a included between the sling and the surface of the concrete. This force may be expressed by the equation:
H = P (cot a).
2
The magnitude of the tensile force on the sling is proportional to the total load and to the angle a. This force may be
expressed by the equation:
T= P
2 sin a .
As angle a decreases, the values of H and T increase. As angle a approaches 0, the magnitude of both H and T approaches
infinity. Conversely, as angle a increases, the values of H and T decrease, so that as angle a approaches 90, force T
approaches the value of 1/2 P and force H approaches 0.
T

See Detail A

R = 1/2 P

Illustration J
Detail A
It is readily apparent that the use of long slings will greatly reduce destructive forces on the slings, the lifting hardware and
on the precast element itself.
d

H
e
SHEAR
C
(d - x)

Illustration K
V

11/12

H = Horizontal component of sling load which is equal


to the induced shear load.
V = Vertical force on insert caused by force H

applied at distance e from face of concrete.
C = Resultant of compressive forces on concrete.
d = Distance from center line of anchor bolt to toe

of bearing plate.
e = Distance from face of concrete to point of

application of force H.
x = Distance from toe of bearing plate to C.
b = Width of bearing plate(not shown)
fc = Ultimate compression strength of the concrete.

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


Transverse and Shear Loading
A transverse force acting on an insert will cause a force pattern on the insert and in the surrounding concrete that is most
easily visualized through a study of Illustration K.
Force H, when first applied, tends to cause a lateral translation and bending of the bolt. If the bolt has been properly
tightened, a lateral movement will be prevented by frictional forces and, more importantly, by the couple of compressive
force C exerted by the toe of the lifting plate on the concrete and the tensile force V.
Only under very rare circumstances will force H be applied at the face of the concrete. Usually, conditions are such that
force H is applied at some distance e above the surface.
As long as the forces acting on the insert are in equilibrium, i.e., up to the point where some resisting element in the force
system fails, the following equations express mathematically the balance of forces in and around the insert.
1. (H) (e) = (C) (d-x) 3. (H) (e) = (V) (d-x)
2. V = C

4. and V = (H) (e).


(d-x)

The only value on the right hand side of this equation that cannot be definitely determined is dimension x. This distance is
determined by the compressive stress pattern under the lifting plate.
If the pattern is triangular:
5. Cmax = ( 1 f'c) (db) and x = d.
2
3
If the pattern is rectangular
6. Cmax = (f'c) (db) and x = d.
2

More probably, the pattern is a trapezoidal compromise and:
7. Cmax = (.85 f'c) (db) and x = 5/12 d.
For any given lifting plate, the value of Cmax will be limited by f'c or by Vmax which is the pull out strength of the insert, since, by
equation (2) V = C.
Test results indicate that the assumption of a rectangular stress pattern is valid and conservative for most conditions.
2 (e) (H)
8. Equation (4) then becomes V =
.
d

Values 2e
for Dayton Superior Lifting Hardware are shown in the Table below.
d
Warning: Lifting plates or other attachment hardware must be bolted
tightly to the concrete, and bolt holes in the plate must not be excessively
larger than the anchor bolt. Disregard for these precautions can cause bolt
bending, excessive unbalanced loading on the insert and possibly a premature failure.
Applying equation (8) to a specific situation: Assume that a B18 " x 9"
Single Flared Coil Loop Insert is being used (safe working load is 4,750lbs.)
together with a T12 Swivel Lifting Plate in such a manner that the vertical
component of the load on the insert is 4,500lbs. and the horizontal
component of load on the insert is 1,000lbs.
(e) (H)
Using equation (8), V = 2
, and values of 2e

d d
from the table, V = .65 x 1000lbs. or 650lbs. of additional pull on the
insert caused by the horizontal component. Adding: 4,500lbs. +
650lbs. = 5,150lbs. This exceeds the rated load of the insert and
requires that a stronger insert be chosen.

10

Lifting Hardware Values


Lifting Plate

Bolt Diameter

2e
d

T8

1", 1-1/4" or
1-1/2"

2.00

T12

3/4"

0.65

T12

1"

0.67

T12H

1-1/4"

0.83

T12H

1-1/2"

0.83

T26H

3/4"

1.46

T26

1"

1.00

T26H

1"

1.46

T26

1-1/2

0.71

T27

3/4" or 1"

3.00

11/12

Calculating Sling/Anchor Loads


Applies to Swift Lift; Fleet-Lift and Utility Anchors
The table shows multiplication factors that are used in a simplified method to determine the
increased load transferred from the sling to the anchor when using multi-leg slings. As the
fleet angle (0) increases, the sling load increases and transfers an even larger to the anchor.
P

P2

P1

Warning: Avoid the use of Fleet Angles greater than 120 as their
use can overload and damage anchors causing a premature failure
resulting in property damage, serious personal injury or death.
P

= Actual weight of precast element including adhesion

Fleet
Angle
0

Multiplication
Factor
F

1.00

16

1.01

30

1.04

45

1.08

60

1.16

75

1.26

0 = Fleet angle

90

1.41

105

1.64

120

2.00

= Multiplication factor

PxF

= Effective weight of precast element

P1 = P2

= Anchor load using 2-leg sling

P1 = P2

= P x F/2 anchors

Calculating Sling/Anchor Loads


Applies to Swift Lift; Fleet-Lift and Utility Anchors
When anchors are not located equally about the center of gravity of the precast element, calculate
the applied anchor loads statically.
The load will always balance under the crane hook. Calculate anchor loads as follows:

P1

P2

P1 = P x b/a + b
P2 = P x a/a + b

Rigging For Traveling Over Rough Ground


When a precast element is to be transported over rough ground, use a 60 V type rigging. This will help reduce
dynamic loads.
When using a forklift to transport precast elements over rough ground, Dayton Superior recommends that the user reduce
the anchor safe working load by 50%. This safe working load reduction will help offset the effects of any dynamic loads
that might occur.
90
90

Resultant
Load on
Anchor

Varies

Reaction of
Anchor

Right

Wrong

Load Diagram Compressive Force in


Concrete

11/12

11

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


Rigging
As with all lifting systems, the selection of the proper lifting anchor is based on several factors. One of the most important
is the accurate determination of the load that will be applied to each anchor. When using certain rigging arrangements it
is impossible to accurately determine the load that is applied to each anchor. This is due to the tolerances in sling lengths
and the location of the lifting anchors in the precast concrete element. In order to eliminate this problem, and make
certain that the applied loads are equalized to each of the lifting anchors, an equalizer (spreader) beam and rollers blocks
are used.
The use of equalizer beams and roller blocks permits a qualified person to determine the exact load distribution. When an
equalizer beam and roller blocks are used in the plant, they must also be used in the field. If the user is in doubt about the
field use of an equalizer beam and roller blocks, then only two anchors should be assumed to be load carrying.
Several typical rigging arrangements are shown below along with a determination as to the number of anchors that will be
load carrying.

120
120
120

Illustration R1

3 anchors will carry load when used on round precast concrete elements with the anchors spaced
120 apart.
2 anchors will carry load when used on square or
rectangular precast elements.

Illustration R4

Illustration R2

2 anchors will carry load when using 4 individual


slings. The other 2 anchors will act to balance the
precast concrete element.

4 anchors will carry load when using 4 individual slings in conjunction with
the Dayton Superior T46 Spreader Beam with Twin 7-1/2-ton Shackles.

Illustration R3

4 anchors will carry load when using 2 individual


slings running over 2 roller blocks supported by
an equalizer beam.

Illustration R5

2 anchors will carry load when using 4 individual slings attached to a 3


beam equalizer beam. This rigging arrangement should be used when
angle pulls need to be avoided.

The above assumes that the anchors are spaced equally about the center of gravity of the precast concrete element and
that the center of lift is directly above the center of gravity. Failure to locate the center of lift directly over the center of
gravity will cause the precast element to tilt.

12

11/12

Selecting the Proper Insert


The following factors should be considered when determining the load per insert:

1) Weight of the concrete shape,

2) Adhesion to the form surface,

3) Type of concrete (normal, lightweight or all lightweight materials),

4) Dynamic loads (impact due to handling, transporting or erecting conditions),

5) Concrete compressive strength at time of initial lift,

6) Number of lifting points and type of rigging to be used,

7) Direction of pull (cable or sling angle),

8) Flexural stresses of thin concrete shapes,

9) Panel thickness,

10) Edge distance (thin wall, free edge or shear loading conditions).

Determining the dead load weight of a precast concrete section is straight forward, although serious errors are easy to
make, such as: 1. Miscalculations involving symmetrical panels; 2. Forgetting that a panel is normal weight concrete and
using the unit weights of lightweight concrete and 3. Neglecting adhesion to the form.
In addition, transporting the panel in the storage yard over bumpy conditions introduces dynamic loads that must also be
anticipated. Removing the precast element from the form can induce forces that, in effect, increase the dead load weight at
a critical time, when the concrete compressive strength is at its lowest value. Depending on the quality of release agent used,
the following adhesion loads should be considered when determining the additional weight of the concrete element:
Concrete Forms

up to 20 Ibs./sq. ft.

Steel Forms

up to 25 Ibs./sq. ft.

Plywood Forms
(Flat Surface)

up to 50 Ibs./sq. ft.

Plywood Forms
(Ribbed Surface)

up to 75 Ibs./sq. ft.

The type of concrete used determines the unit weight characteristics and the resultant ability of the concrete to resist the
pullout forces introduced by the insert. See page 8 for the proper load reduction factors that must be applied to insert safe
working loads when an insert is embedded in lightweight concrete.
Consideration must also be given to dynamic loads that can occur in the plant, in the storage yard, as well as during
transportation to the job site and during erection. It is suggested that a detailed study be made of the various handling,
storage, transporting and erection forces. The user is cautioned to be aware of these additional forces and to give due
consideration to their effect on the inserts safe working load.

Example One
Select the proper length and capacity of insert based on the use of a spreader
frame, as shown below, that will allow equal loading on all four inserts. Assume
normal weight concrete having a compressive strength of 2,700 psi at initial lift.
Dead Load Weight = 15' x 8' x 12.5 Ibs./sq. ft. x 6" = 9,000 Ibs.
Adhesion to Form = 15' x 8' x 75 Ibs./sq. ft. =
(Ribbed Surface)

18,000 Ibs.
= 4,500 Ibs./insert
"

18,000 Ibs.
4 inserts

'-0

Required Insert Capacity =


Maximum Insert Height = 5-1/2"


 elect the following insert: P52 4 ton x 4" long Swift Lift Anchor in 3,000 psi
S
normal weight concrete.

90

6"

15

Effective Weight of Panel =

9,000 Ibs.

8'-0"

Illustration M

11/12

13

General and
Technical
Information

General and Technical Information

Example Two
Select the proper length and capacity of insert, based on the use of a spreader beam and slings at a 60 angle with the top
surface of the precast section. Assume normal weight concrete having a compressive strength of 4,000 psi at initial lift and
the use of 1" diameter T12 Swivel Lifting Plates.
Dead Load Weight = 20' x 7' x 12.5 Ibs./sq. ft. x 6" = 10,500 Ibs.
Adhesion to Form = 20' x 7' x 25 Ibs./sq. ft. =
3,500 Ibs.
Effective Weight of Panel =
14,000 Ibs.
Therefore, the vertical reaction that must be carried by each
14,000lbs.
insert =
= 3,500lbs.
4 inserts
= 3,500 Ibs. x cot. 60 = 3,500 Ibs. x .578 or
= 2,023 Ibs./insert
2e
=
x 2,023 Ibs. = .65 x 2,023 or
d

V

V = 1,315 Ibs./insert
Required Insert Capacity = 3,500 Ibs. + 1,315 Ibs.

= 4,815 Ibs./insert
Maximum Insert Height = 5"
Select the following insert: F56 Expanded Coil Insert,

1" diameter x 5-1/2" long,

6,250 Ibs. Safe Working Load.
Check combined tension and shear as follows:

6"

'-0
"

H
H

60

20

7'-0"

Illustration N

5/3
5/3 = .80. Since this is less than 1.0, the insert which was
( 4,815lbs.
( 2,023lbs.
4,800lbs. )
selected is suitable for use.
6,250lbs. )
+

Example Three

'-0

Dead Load Weight = 9' x 10' x 9.58 Ibs./sq. ft. x 14" =


12,071 Ibs.
9' x 10' x 20 Ibs./sq. ft. =
1,800 Ibs.
Adhesion to Form =
Effective Weight of Precast Section =
13,871 Ibs.
Therefore, the vertical reaction that must be carried by each
13,871lbs.
=
6,936lbs.
insert =

2 inserts
60
H=
6,936 Ibs. x cot. 60 = 6,936 Ibs. x .578 or
14"
H=
4,009 Ibs./insert
2e
V =
x 4,009 Ibs. = .833 x 4,009 Ibs. or

d
9'-0
"
V=
3,339 Ibs./insert
Required Insert Capacity = 6,936 Ibs. + 3,339 Ibs. = 10,275 Ibs./insert
Illustration P
Maximum Insert Height = 13-1/2"
Select the F60 Expanded Coil Insert, 1-1/2" diameter x 12" long, 16,250lbs. Safe Working Load.
Multiply Safe Working Load by reduction factor of .7 for lightweight concrete,
16,250 Ibs. x .7 = 11,375 Ibs. Safe Working Load in lightweight concrete.

"

Select the proper length and capacity of an insert based on the use of a four sling lift (see warning note below) with cables
at a 60 angle to the top surface of the precast section. Assume lightweight concrete having a unit weight of 115lbs./cu.
ft., a compressive strength at initial lift of 4,000 psi and the use of 1-1/2" diameter T12 Swivel Lift Plates.

10

General and
Technical
Information

General and Technical Information

As the reduced Safe Working Load is greater than the 10,275 Ibs. Ioad required, it appears this insert is suitable for use.
However, combined shear and tension must be checked as follows:
5/3
4,009lbs. 5/3
(10,275lbs.
( 11,750lbs.
) = 1.01, which means this insert must be replaced with a stronger insert.
11,375lbs.)
+

Warning: When individual slings are used, any two inserts must be capable of lifting/handling the precast section. This is
due to unequal sling lengths and the resulting loads that are transferred to the shorter slings. In this application, only two
slings carry the total load while the other two slings are simply used to balance the load.

14

11/12

Coil Insert Safe Working Load Reduction Factors For Free Edge Conditions
Tension Loadings Only
D
P

Minimum
D + de

de = Free edge distance


Concrete
Face

de

D = Minimum edge distance required to develop


a full shear cone is 1.5 x the insert length
2D = Minimum insert spacing when using two or
more inserts
Note: For insert capacities under shear loading
conditions, please refer to Transverse and
Shear Loading.

de
2"
2-1/4"
2-1/2"
2-3/4"
3"
3-1/2"
4"
4-1/2"
5"
5-1/2"
6"
7"
8"
9"
10"
11"

6"
0.63
0.64
0.65
0.67
0.69
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
1.00
1.00

B1 or B2
8"
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96

B16
12"
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96

4"
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96
1.00
1.00
1.00
1.00
1.00
1.00

6"
0.61
0.63
0.64
0.65
0.67
0.69
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
1.00
1.00

B17
12"
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
0.92
0.96

B18
9"
0.57
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91

Insert Type and Length


B33
F53
12"
12"
3"
4"
0.58
0.72
0.67
0.59
0.75
0.69
0.60
0.78
0.71
0.61
0.81
0.73
0.63
0.83
0.75
0.65
0.89
0.79
0.67
0.67
0.94
0.83
0.69
0.69
1.00
0.88
0.71
0.71
1.00
0.92
0.73
0.73
1.00
0.96
0.75
0.75
1.00
1.00
0.79
0.79
1.00
1.00
0.83
0.83
1.00
1.00
0.88
0.88
1.00
1.00
0.92
0.92
1.00
1.00
0.96
0.96
1.00
1.00

4-1/2"
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
1.00
1.00
1.00
1.00

F56 to F61
5-1/2" 7-1/2"
0.65
0.61
0.67
0.62
0.68
0.63
0.71
0.66
0.74
0.68
0.77
0.70
0.80
0.72
0.83
0.74
0.86
0.77
0.92
0.81
0.98
0.86
1.00
0.90
1.00
0.94
1.00
0.99

9-1/2"
0.60
0.61
0.62
0.64
0.66
0.68
0.69
0.71
0.75
0.78
0.82
0.85
0.89

2-2/8"
0.79
0.82
0.86
0.90
0.93
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

F63
3-1/2"
0.69
0.71
0.74
0.76
0.79
0.83
0.88
0.93
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00

4-1/2"
0.65
0.67
0.69
0.70
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
1.00
1.00
1.00
1.00

Reduced Safe Working Load is based on 1/2" setback from face of concrete.
For Safe Working Load on other insert loading conditions, contact a Dayton Superior Technical Service Department.
Above chart modified from ACI 318 Appendix D method by using previous results from product testing.

How to Use Reduction Factors:


To obtain an inserts reduced safe working load for free edge conditions, multiply the safe working load listed in the insert
selection chart by the appropriate reduction factor from the above chart. Do not apply these reduction factors to other
types or sizes of inserts.

Example:
Using a B2 Coil Tie Insert 1" x 8" long in a 2-1/2" free edge condition, multiply concrete safe working load of 9,514lbs. by a
reduction factor of 0.6 to arrive at the reduced concrete safe working load of 5,708lbs. which is less than insert mechanical
capacity of 9,000lbs. so use 5,708lbs.

11/12

15

General and
Technical
Information

General and Technical Information

General and
Technical
Information

General and Technical Information


Coil Insert Safe Working Load Reduction Factors For Thin Wall Conditions
Tension Loadings Only
D

Concrete
Face

de

T =

Wall thickness

de = Actual edge distance


D = Minimum edge distance required to
develop a full shear cone is 1.5 x the insert
length
2D = Minimum insert spacing when using two or
more inserts
Note: For insert capacities under shear
loading conditions, please refer to page 12.

Insert Type and Length


T

de

B1 or B2
6"

8"

B16

B17

B18

B33

F53

F56 to F61

12"

4"

6"

12"

9"

12"

12"

3"

4"

F63

4-1/2"

5-1/2"

7-1/2"

9-1/2"

2-2/8"

3-1/2"

4-1/2"

4"

2"

0.33

0.22

0.15

0.17

0.44

0.33

0.58

0.38

0.30

4-1/2"

2-1/4"

0.25

0.19

0.19

0.38

0.25

0.17

0.19

0.50

0.38

0.33

0.65

0.43

0.33

5"

2-1/2"

0.28

0.21

0.21

0.42

0.28

0.19

0.21

0.56

0.42

0.37

0.30

0.22

0.72

0.48

0.37

5-1/2"

2-3/4"

0.31

0.23

0.23

0.46

0.31

0.20

0.23

0.61

0.46

0.41

0.33

0.24

0.19

0.79

0.52

0.41

6"

3"

0.33

0.25

0.25

0.50

0.33

0.22

0.25

0.67

0.50

0.44

0.36

0.27

0.21

0.86

0.57

0.44

7"

3-1/2"

0.39

0.29

0.29

0.58

0.39

0.26

0.29

0.78

0.58

0.52

0.42

0.31

0.25

1.00

0.67

0.52

8"

4"

0.44

0.33

0.33

0.67

0.44

0.33

0.30

0.33

0.33

0.89

0.67

0.59

0.48

0.36

0.28

1.00

0.76

0.59

9"

4-1/2"

0.50

0.38

0.38

0.75

0.50

0.38

0.33

0.38

0.38

1.00

0.75

0.67

0.55

0.40

0.32

1.00

0.86

0.67

10"

5"

0.56

0.42

0.42

0.83

0.56

0.42

0.37

0.42

0.42

1.00

0.83

0.74

0.61

0.44

0.35

1.00

0.95

0.74

11"

5-1/2"

0.61

0.46

0.46

0.92

0.61

0.46

0.41

0.46

0.46

1.00

0.92

0.81

0.67

0.49

0.39

1.00

1.00

0.81

12"

6"

0.67

0.50

0.50

1.00

0.67

0.50

0.44

0.50

0.50

1.00

1.00

0.89

0.73

0.53

0.42

1.00

1.00

0.89

14"

7"

0.78

0.58

0.58

1.00

0.78

0.58

0.52

0.58

0.58

1.00

1.00

1.00

0.85

0.62

0.49

1.00

1.00

1.00

16"

8"

0.89

0.67

0.67

1.00

0.89

0.67

0.59

0.67

0.67

1.00

1.00

1.00

0.97

0.71

0.56

1.00

1.00

1.00

18"

9"

1.00

0.75

0.75

1.00

1.00

0.75

0.67

0.75

0.75

1.00

1.00

1.00

1.00

0.80

0.63

1.00

1.00

1.00

20"

10"

1.00

0.83

0.83

1.00

1.00

0.83

0.74

0.83

0.83

1.00

1.00

1.00

1.00

0.89

0.70

1.00

1.00

1.00

22"

11"

1.00

0.92

0.92

1.00

1.00

0.92

0.81

0.92

0.92

1.00

1.00

1.00

1.00

0.98

0.77

1.00

1.00

1.00

Reduced Safe Working Load is based on 1/2" setback from face of concrete.
For Safe Working Load on other insert loading conditions, contact a Dayton Superior Technical Service Department.
When an insert is not positioned at the center line of the wall, the effective wall thickness is twice the actual edge distance. Above chart modified from ACI
318 Appendix D method by using previous results from product testing.

How to Use Reduction Factors:


To obtain an inserts reduced safe working load for thin wall conditions, multiply the safe working load listed in the insert
selection chart by the appropriate reduction factor from the above chart. Do not apply these reduction factors to other
types or sizes of inserts.

Example:
Using a B2 Coil Tie Insert 1" x 12" long in an 8" thin wall, multiply concrete full shear cone capacity of 17,525 by a reduction
factor of 0.33 to arrive at the reduced concrete safe working load of 5,783lbs. which is less than insert mechanical
capacity of 9,000lbs. so use 5,783lbs.

16

11/12

Swift Lift System

The Swift Lift System is a quick connect-disconnect system that allows precast concrete elements to be handled repeatedly,
with speed, safety and economy. It is a non-welded system and void of threaded connections. The quality, reusable Swift
Lift Lifting Eyes heavy duty construction will provide years of good service.
The Swift Lift System is available with safe load ratings of 1, 2, 4, 8 and 20 tons. Each component is clearly marked with its
maximum safe working load. The System is extremely versatile and can be utilized for vertical and diagonal pulls. It can be
used to lift concrete elements from a horizontal to a vertical position without the aid of a tilting table.

P50 Swift Lift Universal Lifting Eye DS_P50

B
A

The Swift Lift Universal Lifting Eye (P50) consists of a flatsided, spherical lifting body and a high strength bail. The
lifting body has a T-shaped slot that permits rapid attachment
and release of the head on Swift Lift Anchors.
Bail

DSC

The design of the P50 Universal Lifting Eye permits the


bail to freely rotate 180, while the complete lifting eye
may rotate through a 360 arc. This design feature allows
precast concrete elements to be turned, tilted and/or rotated
under load.

Dayton Superior does not recommend the use of this lifting


eye for edge lifting of thin precast concrete panels.

Load
Range
Tons

Lifting
Body

M
H
F

P50 Swift Lift Universal Lifting Eye Dimensions


Rated Load
Tons

1.87"

2.95"

2.20"

1.26"

2.80"

7.40"

2.34"

3.58"

2.68"

1.61"

3.41"

9.06"

2.76"

4.65"

3.46"

2.22"

3.46"

11.14"

3.47"

6.30"

4.41"

2.83"

4.52"

15.79"

20

4.18"

7.09"

6.00"

4.29"

5.31"

20.00"

The rated load provides a factor of safety of approximately 5 to 1 (ultimate to rated load).

P50 Inspection and Maintenance


The P50 Universal Lifting Eye may be subjected to wear, misuse, overloading and
other factors that can affect the lifting eyes rated load. Therefore, it is imperative
that the lifting eye be user-inspected at least once a month to determine its general
condition and degree of wear.
During the users monthly inspection, the lifting eye should be checked for evidence
of heat application. If evidence of heat application is found, the unit must be
scrapped. Check for a bent or twisted bail and discard all units found to have these
flaws. Also, check to make certain that the bail rotates freely in all directions.

Limiting Dimensions on
P-50 Swift Lift Universal Lifting Eye
(Tons)

H
Maximum
Width

M
Minimum
Thickness

0.512"

0.217"

0.709"

0.236"

0.984"

0.315"

1.260"

0.472"

20

1.811"

0.709"

Rated
Load

At least once every three months, dimensions H and M on each unit should be checked. The upper limits are shown in
the chart. If either of these limits is exceeded, the P50 Universal Lifting Eye must be removed from service and destroyed.
The proper method for scrapping a lifting eye is to cut through the bail with a cutting torch to render the unit useless as a
lifting device.
No repairs or welding to the P50 Swift Lift Universal Lifting Eye are permitted.

11/12

17

Swift Lift System

Swift Lift System

Swift Lift System

How to Use the P50 Swift Lift Universal Lifting Eye


Swift Lift System

Extended Lip

1. To install the P50 lifting eye, hold


the unit upside down with the
T-shaped slot directly over the
head of the Swift Lift anchor.

2. Lower the lifting eye down


onto the anchor until the Tslot
engages the head of the anchor.

3. Rotate the lifting eye until the


extended lip of the body touches the
horizontal surface of the concrete.

Note: Prior to lifting a precast element, apply an initial cable tension to make sure that the bail and body of the lifting eye are aligned in the direction
of the cable pull.

180 Usable
Range

The bail of the P50 lifting eye can


move through a 180 usable range.

Minimum
Edge
Distance

Minimum
Edge
Distance
360
Range

The main body of the lifting eye


has a 360 rotational range.

The P50 lifting is used with the T-shaped


slot facing toward the direction of the
applied load.

To disengage the lifting eye, the crane


hook is lowered and the body removed
by rotating the extended lip upward.

90 or
more

Right

Right

less than
90

Wrong

Dos and Donts of the P50 Swift Lift Universal Lifting Eye
Prior to lifting a precast element,
apply an initial cable tension to make
certain that the bail and body of the
lifting eye are aligned in the direction
of the cable pull.

When applying the initial cable


tension on edge lift applications,
make sure that the cables are at a 90
angle (or larger) to the surface of the
precast element.

Warning: Do not allow the crane lines to form an


angle less than 90 during an edge lift application.
This condition can bend the lifting eye bail and
could lead to a premature failure.

Warning: The crane line and bail of the lifting hardware must be turned in the direction of the cable forces before the lifting operation begins. The crane line
must not be allowed to apply a sideward force on the bail. This condition is dangerous and could lead to premature failure of the hardware or insert.
Warning: Do not modify, weld or alter in any way the Swift Lift Universal Lifting Eye.

18

11/12

Swift Lift System

DS_P51
B
A

4
Year of
Manufacture

DSC

The P51 Swift Lift Lifting eye is a high quality, high


strength steel casting. Its ball-shaped lower end fits
into the void formed in the concrete and engages
the spherical head of the anchor. Attachment
to the anchor head can only be made when the
lifting eye is positioned with its front face toward
the concrete. In the working position, release is
impossible. Accidental disengagement is prevented
by a gravity-action safety pin that must be raised
before the Lifting Eye can be removed.

Swift Lift System

P51 Swift Lift Lifting Eye

D
E

The P51 Swift Lift Lifting Eye is available with


safe working loads of 2, 4 and 8 tons. It is
extremely versatile in use, being suitable for
vertical pull or diagonal pull. The Lifting Eye
rotates freely (360) about the vertical axis of
the anchor. Each unit is clearly marked with its
MAXIMUM safe working load.

Bail

Load
Range
Tons

Safety Pin

C
F

P51 Swift Lift Lifting Eye Selection Chart


Safe
Working
Load (tons)

(Inches)

(Inches)

(Inches)

(Inches)

(Inches)

2.64

4.52

2.36

3.74

8.43

3.00

5.06

2.83

4.96

10.35

3.54

5.98

3.70

5.60

12.87

Safe Working Load provides a factor of safety of approximately 5 to 1.

Inspection and Maintenance


While appreciable wear does not normally occur, the P51 Swift Lift
Lifting Eye may be subjected to wear, misuse, overloading and other
factors that may affect the lifting eyes rated load. Therefore, the
user must inspect lifting eyes at least once a month to determine
general condition, degree of wear and any evidence of heat
application.
If evidence of heat application is found, the unit must be destroyed.
In addition, check to make certain that the bail is not bent or twisted.
Destroy all units that have a bent or twisted bail.

Limiting Dimensions on
P51 Swift Lift Lifting Eye
Safe
Working
Load (tons)

(Inches)

(Inches)

0.709

0.236

0.984

0.315

1.260

0.472

Check the safety pin; missing pins must be replaced. Make sure the safety pin is in good condition and moves freely
at all times. At least once every three months, dimensions G and F on each unit should be checked. The upper
limits are shown in the chart. If either of these limits is exceeded, the Swift Lift Lifting Eye must be removed from
service and destroyed.
The proper method to use in destroying a lifting eye is to cut through the bail with a cutting torch. Other than replacing
the safety pin, no repairs to the P51 Swift Lift Lifting Eye are permitted. In particular, welding is not permitted.

11/12

19

Swift Lift System


How to Install The P51 Swift Lift Lifting Eye
Swift Lift System

To engage the P51 Swift Lift Lifting Eye on the head of the Swift Lift Anchor, position the P51 Swift Lift Lifting Eye so that
the front face is toward the concrete, then raise the Swift Lift Lifting Eye into the working position and engage the lifting
hook. The safety pin will drop into position to prevent accidental release of the Swift Lift Lifting Eye.
For inclined pulls, the front face of the P51 Swift Lift Lifting Eye, which indicates the rated load of the lifting eye, must
always be facing away from the concrete surface. This must be checked immediately before the lifting operation begins.

Load rating
embossed on front
face in two locations
Front
face

Initial positioning of the P51


Swift Lift Lifting Eye onto the
Swift Lift Anchor

90 or
less

Working position for lifting


of a precast concrete
element

Warning: If the P51 Swift Lift Lifting Eye is used when its relative position is 90 or 180 from its correct position, the P52
Swift Lift Anchor will be overloaded and may result in a premature failure.

Load Rating
Load Rating

Correct position
(Normal position)

Right

20

Incorrect position
(90 out of position)

Incorrect position
(180 out of position)

Wrong
Wrong
Note: Do not use the lifting eye in this manner as it could bend
and/or break the safety pin, allowing the lifting eye to pull off the
Swift Lift Anchor. Never use lifting eye without a safety pin in
place.

11/12

Swift Lift System

When the P51 Swift LIft Lifting Eyes position is changed from a diagonal pull to a vertical pull relative to the anchor axis,
all movements are permissible, even with simultaneous rotation.
If the Swift Lift Anchor is positioned in a relatively thin panel, movement of the P51 Swift Lift Lifting Eye under load from
the vertical to an inclined position relative to the axis of the anchor (such as laying down a panel with edge inserts as
shown in 1 below) is NOT PERMITTED due to excessive friction. This friction causes binding of the ball end of the P51 Swift
Lift Lifting Eye, and when the friction is overcome, the resultant sudden movement causes high impact stresses on the
surrounding concrete. As an aid in reducing friction, apply a soap solution to the void formed by the recess plug.

Right
4. Maneuvering from vertical to
horizontal with face anchors

in.
90 M ax.
120 M

90

Wrong
Right
1. Maneuvering from horizontal to vertical with edge anchors

in.
90 MMax.
120

90

90

The above maneuver can be accomplished when the proper rigging is used. The fleet angle between the slings must be
between 90 and 120. In this manner, precast concrete shapes can be placed from the vertical to the horizontal.

in.
90 M x.
a
M

120

Wrong

90

Right
Wrong
2. Maneuvering from vertical to horizontal with edge anchors
Note: To reduce friction between the Swift Lift Lifting Eye and the
concrete, apply a soap solution to the cavity formed by the recess plug.

in.
90 M
.
Max
120

Right
Wrong
3. Maneuvering from horizontal to vertical with face anchors
Note: To reduce friction between the Swift Lift Lifting Eye and the
concrete, apply a soap solution to the cavity formed by the recess plug.

11/12

21

Swift Lift System

How to use the P51 Swift Lift Lifting Eye

Swift Lift System


P52 Swift Lift Anchor DS_P52

Load Rating

Swift Lift System

The P52 Swift Lift Anchor is hot forged from carbon steel. The formed
head provides spherical seating that the Lifting Eye engages, while a discshaped foot is embedded in the concrete.

4
Head

Caution: The Swift Lift


Anchor is designed to be
used with Dayton Superior
components. Failure to
use this combination may
result in concrete spalling
or premature failure.

Due to its being a forged part, the Swift Lift Anchor does not depend on
welds or thread engagement to develop its safe working load. Forging
provides maximum safety with its advantageous material structure. This
allows the anchor to easily meet the OSHA requirement of a 4 to 1 factor
of safety.
In addition to the carbon steel anchors, Type 304 or 316 Stainless Steel
Swift Lift Anchors are available on special order. Use stainless steel anchors
when maximum protection against corrosion is required.
For safety, refer to the P52 Swift Lift Anchor Selection Chart to determine
the actual safe working load of an individual anchor. The MAXIMUM
safe working load is clearly visible on the head of the anchor for easy
recognition of the appropriate hardware and accessories foruse with each
Swift Lift Anchor.

Shaft
Diameter

Foot

To Order:
Specify: (1) quantity, (2) name, (3) system size,
(4) length

Example:
200, P52 Swift Lift Anchors, 4 ton, 9-1/2" long

P52 Swift Lift Anchor and Recess Plug Dimensions


Diameter

Head
Diameter
X

Z
Y

Swift Lift Round Recess Plug


Swift Lift Round Recess Plug Dimensions
Shaft
Diameter

Diameter
of Foot

Swift Lift
Anchor

Diameter of
Recess Plug

Dimension
Z

2-7/16"

1-3/16"

3-5/16"

1-7/16"

4"

1-13/16"

5"

2-5/16"

20 Tons

6-3/8"

3-1/8"

Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

P52 Swift Lift Anchor

P52 Swift Lift Anchor Dimensions

22

Swift Lift
Anchor

Dimension
X

Dimension
Y

Shaft
Diameter

Foot
Diameter

Head
Diameter

5/16"

7/8"

3/8"

1"

11/16"

7/16"

1-1/16"

9/16"

1-3/8"

1-1/32"

9/16"

1-5/16"

3/4"

1-7/8"

1-11/32"

9/16"

1-5/8"

1-3/32"

2-5/8"

1-7/8"

20 Tons

9/16"

2-5/8"

1-1/2"

3-3/4"

2-3/4"

11/12

Swift Lift System


How to Install P56 and P56PL Recess Plugs on P52 Anchors
Swift Lift System

Grasp the recess plug firmly across the top diameter of the plug. Application of pressure
by the thumb and fingers on the outer edge of the plug will cause the plug to open up
to allow insertion of the anchor.

Wet Setting P52 Swift Lift Face Lift Anchors


When a Swift Lift anchor is to be positioned in the top surface of a flat precast
section, wet setting the anchor is best done immediately after the concrete has been
placed.
The anchor/recess plug assembly is attached to a small template board and pressed
into the fresh concrete until the template board lies flush on the surface of the
concrete.
Light vibration of the fresh concrete will assure proper embedment and anchorage.

Anchor assembly
attached to
template board

Recess Plug Removal


Swift Lift recess plugs provide two holes in the top surface that are used in the removal process. Insert two
screw drivers or steel rods into the holes and simply lever the two across the plug for easy removal.

Selecting the Proper Swift Lift Anchor


Determination of the required rated load and length of a P52 Swift Lift Anchor is based on the actual maximum load that is
transferred to the anchor. In most cases, a flat slab can be handled with the anchors properly located in the face of the flat
slab. The anchors should normally be the maximum length that can be accommodated in the slabs structural thickness,
allowing at least 1/2" clearance between the anchor and the casting bed. Dimension tables and safe working load charts,
contained herein, will aid in the selection of the proper anchor. Keep in mind that the safe working load of an anchor is a
function of several factors:
1. The effective concrete thickness
2. Actual edge distance
3. Concrete compressive strength at time of lift
4. Anchor length
5. In some applications, the use of a shear bar

11/12

23

Swift Lift System


P52 Swift Lift Anchor Tensile and Shear Capacity
Swift Lift System

When anchors are used in the face of thin concrete elements


The following table lists the P52 Swift Lift Anchors that are currently
manufactured. Other sizes and lengths are available on special order.
However, the sizes and lengths of anchors shown will handle the majority
of flat precast concrete elements.

ge
Ed
e
m
u nc
im ta
in Dis
M

Min
imu
Distam Edge
nce
PD
PV

PT

When the P52 Swift Lift Anchor is properly embedded in normal weight
concrete, the tabulated working loads are applicable for any direction of
load. This applies even if the direction of load is parallel to the axis of the
anchor, perpendicular to it or at any other angle.
Minimum distance between anchors is twice the minimum edge distance.
It is critical to remember that in order to obtain the safe working loads
listed in the table below, the normal weight concrete must have obtained
the minimum concrete strength shown, prior to initial load application.
Swift Lift Anchor
Ton x Length

Safe Working
Load

Minimum
Concrete Strength

Minimum
Edge Distance

1 ton x 2-5/8"

1,700lbs.

3,500 psi

8"

1 ton x 3-3/8"

2,000lbs.

2,200 psi

10"

1 ton x 4-3/4"

2,000lbs.

1,600 psi

10"

1 ton x 8"

2,000lbs.

1,600 psi

10"

1 ton x 9-1/2"

2,000lbs.

1,600 psi

10"

2 ton x 2-3/4"

2,100lbs.

3,500 psi

8"

2 ton x 3-3/8"

2,900lbs.

3,500 psi

10"

2 ton x 4-3/4"

4,000lbs.

3,500 psi

7.125"

2 ton x 5-1/2"

4,000lbs.

1,600 psi

13"

2 ton x 6"

4,000lbs.

1,600 psi

13"

2 ton x 6-3/4"

4,000lbs.

1,600 psi

13"

2 ton x 11"

4,000lbs.

1,600 psi

14"

4 ton x 3-3/4"

4,000lbs.

3,500 psi

12"

4 ton x 4-1/4"

4,900lbs.

3,500 psi

13"

4 ton x 4-3/4"

5,800lbs.

3,500 psi

14"

4 ton x 5-1/2"

7,400lbs.

3,500 psi

17"

4 ton x 5-3/4"

7,900lbs.

3,500 psi

17"

4 ton x 7-1/8"

8,000lbs.

1,800 psi

20"

4 ton x 9-1/2"

8,000lbs.

1,600 psi

17"

4 ton x 14"

8,000lbs.

1,600 psi

18"

4 ton x 19"

8,000lbs.

1,600 psi

20"

8 ton x 4-3/4"

6,400lbs.

3,500 psi

7.875"

8 ton x 5-1/4"

6,850lbs.

3,500 psi

16"

8 ton x 6-3/4"

11,200lbs.

3,500 psi

21"

8 ton x 10"

16,000lbs.

3,500 psi

19"

8 ton x 13-3/8"

16,000lbs.

1,600 psi

23"

8 ton x 26-3/4"

16,000lbs.

1,600 psi

27"

20 ton x 10"

25,000lbs.

3,500 psi

24"

20 ton x 19-3/4"

40,000lbs.

3,500 psi

31"

Safe Working Loads provide a factor of safety of approximately 4 to1 in normal weight concrete. Safe Working Load is
based on anchor setback from face of concrete X dimension, as shown on page 26.

24

11/12

Swift Lift System


P52W Swift Lift Anchor DS_P52W

Safe Working Load provides a factor of safety of approximately 4 to 1.

Swift Lift System

The P52W Swift Lift Anchors are the shortest 2-ton and 4-ton Swift Lift Anchors available and have been
specially modified. A Type W Plain Washer is placed on the anchors foot and welded in position. This
modification has been made in order to increase the Safe Working Load of these short Swift Lift Anchors in
thin precast concrete elements.
W

To Order:
Specify: (1) quantity, (2) name, (3) system size.

Example:
200, P52W Swift Lift Anchors, 2 ton.
Swift Lift Anchor
Tons x Length

Safe
Working Load

Minimum Concrete
Strength

Minimum Edge
Distance

2 tons x 2-3/4"

3,700 lbs.

4 tons x 3-3/4"

5,700 lbs.

3,500 psi

8"

2-1/2"

3,500 psi

12"

2-3/4"

P52 Swift Lift Anchors for Edge Lifting


The P52 Swift Lift Anchors and P51 Swift Lift Lifting Eyes are useful for raising
precast concrete panels from their horizontal casting position to a vertical
position for handling and shipping. When Swift Lift Anchors are used in thin
precast panels and under shear loading conditions, a special shear bar must
be used.

Casting Surface
P59 Shear Bar

C/2
equ
m
a
corn inimumls
er d
istan
ce

The applied shear load tends to bend the anchor, allowing the lifting
eye to apply load to the thin concrete section above the recess plug. A
properly installed shear bar captures the applied load and transfers it
deeper into the concrete.
When raising precast panels from a horizontal position to a vertical position,
always check both shear and tension safe working loads. In order to develop
the anchors shear safe working load, the minimum spacing between Swift
Lift Anchors is two times the corner distance listed.
Note: Properly installed shear bars are required to develop Safe Working
Loads shown. 2 x de equals effective wall thickness for tensile loads.

dse
de
Support anchor
with bar chair

P52 Swift Lift Anchor

Note: See Shear Bar Chart on page 30.


P51 Swift Lift Lifting Eye

1/2" clear for 1- and 2-ton anchors


3/4" clear for 4- and 8-ton anchors

Lifting eye bears


against shear bar which
transfers load deeper
into the concrete

P
dse (top)

Position P59
shear bar
tight against
recess plug

P52 Swift Lift Anchor

de (bottom)
Casting surface

Section View of Swift Lift


Assembly

11/12

25

Swift Lift System

Swift Lift System

P59 Swift Lift Shear Bar DS_P59


P59 Swift Lift Smooth Wire Shear Bar
Dayton Superior Swift Lift Shear Bars (P59) are utilized when edge lifting precast
elements. The shear bar is secured tightly to the recess plug and at the time of
lift helps to transfer the shear load deeper into the concrete. The P59 Smooth
Wire Shear Bar is designed to snap into the built-in clips on the P54 recess plug.
The standard shear bar is fabricated from rebar and must be securely wired
tightly to the Swift Lift recess plugs.

P59 Swift Lift Shear Bar


1-Ton and 8-Ton
Wire Diameter

To Order:
Specify: (1) quantity, (2) name, (3) system size.

Example:

Overall Width

200, P59 Swift Lift Shear Bars, 4-Ton.

P59 Swift Lift Smooth Wire Shear Bar


2-Ton and 4-Ton

Wall
Thickness

Minimum
Corner
Distance

Safe
Working
Load

4-3/4"

5"

15"

1,750 lbs.

4-3/4"

5-1/2"

16"

2,000 lbs.

19"

4-3/4"

6"

17"

2,000 lbs.

24"

6-3/4"

5"

15"

1,750 lbs.

24"

6-3/4"

5-1/2"

16"

2,200 lbs.

24"

6-3/4"

6"

17"

2,600 lbs.

Wire

24"

6-3/4"

7"

19"

2,700 lbs.

Wire

24"

6-3/4"

8"

21"

2,800 lbs.

Wire

30"

9-1/2"

5-1/2"

16"

2,100 lbs.

Wire

30"

9-1/2"

6"

17"

2,200 lbs.

Wire

30"

9-1/2"

7"

19"

2,600 lbs.

Wire

30"

9-1/2"

8"

21"

2,800 lbs.

Rebar

34"

13-3/8"

8"

19"

5,600 lbs.

Rebar

34"

13-3/8"

9"

21"

6,700 lbs.

Shear Bar
Type

Overall
Width

Minimum
Anchor
Length

Rebar

19"

Rebar

19"

Rebar

Wire

Wire

Wire

Anchor Safe
Working Load
(tons)

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

26

11/12

Swift Lift System

The P52 Swift Lift Anchors, listed below, must be located the minimum distance away from a corner with the anchor foot
being positioned at the center line of the wall. The anchor head location may be off center, however, any eccentricity of
the foot will result in a reduction of the safe working load. When the anchor foot is not positioned at the center line of the
wall, the effective wall thickness is equal to twice the actual edge distance.
To develop the safe working load of the P52 Swift Lift Anchor, the minimum spacing between two anchors is six times the
anchor length.
P

Corner Distance
L = P52
Anchor
Length

Wall
center
line
de

Effective
Wall
Thickness

Center Line
of Anchor Foot
and Wall

de

de

Actual Wall
Thickness

Effective
Wall Thickness

de = Actual Edge Distance


Wall Thickness

Swift Lift Anchor Effective Tensile Capacity in Thin Walls


Swift Lift
Anchor
Ton x
Length

1 Ton
x
4-3/4"
Long

1 Ton
x
9-1/2"
Long

Tensile Safe Working Load Per Anchor

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

6"

12"

18"

24"

30"

2-1/2"

1-1/4"

900 lbs.

1,100 lbs.

1,200 lbs.

1,200 lbs.

1,200 lbs.

2-3/4"

1-3/8"

1,000 lbs.

1,200 lbs.

1,300 lbs.

1,300 lbs.

1,300 lbs.

3"

1-1/2"

1,100 lbs.

1,300 lbs.

1,400 lbs.

1,400 lbs.

1,400 lbs.

3-1/2"

1-3/4"

1,200 lbs.

1,600 lbs.

1,600 lbs.

1,600 lbs.

1,600 lbs.

Actual Corner Distance

4"

2"

1,450 lbs.

1,800 lbs.

1,900 lbs.

1,900 lbs.

1,900 lbs.

4-1/2"

2-1/4"

1,600 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2-1/2"

1-1/4"

1,300 lbs.

1,700 lbs.

1,900 lbs.

1,900 lbs.

1,900 lbs.

2-3/4"

1-3/8"

1,400 lbs.

1,900 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

3"

1-1/2"

1,500 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

3-1/2"

1-3/4"

1,800 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

4"

2"

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

4-1/2"

2-1/4"

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

11/12

27

Swift Lift System

P52 Swift Lift Anchor in Thin Walls

Swift Lift System


Swift Lift Anchor Effective Tensile Capacity in Thin Walls
Swift Lift System

Swift Lift
Anchor
Tons x
Length

2 Tons
x
6-3/4"
Long

2 Tons
x
11"
Long

Tensile Safe Working Load Per Anchor

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

8"

12"

18"

24"

30"

Actual Corner Distance

3"

1-1/2"

1,500 lbs.

1,700 lbs.

2,000 lbs.

2,000 lbs.

2,000 lbs.

3-1/4"

1-5/8"

1,600 lbs.

1,900 lbs.

2,100 lbs.

2,200 lbs.

2,200 lbs.

3-1/2"

1-3/4"

1,700 lbs.

2,000 lbs.

2,300 lbs.

2,300 lbs.

2,300 lbs.

4"

2"

2,000 lbs.

2,300 lbs.

2,600 lbs.

2,700 lbs.

2,700 lbs.

5"

2-1/2"

2,500 lbs.

2,900 lbs.

3,300 lbs.

3,400 lbs.

3,400 lbs.

6"

3"

3,000 lbs.

3,500 lbs.

4,000 lbs.

4,000 lbs.

4,000 lbs.

3"

1-1/2"

1,900 lbs.

2,300 lbs.

2,700 lbs.

3,000 lbs.

3,200 lbs.

3-1/4"

1-5/8"

2,100 lbs.

2,500 lbs.

3,000 lbs.

3,300 lbs.

3,500 lbs.

3-1/2"

1-3/4"

2,200 lbs.

2,700 lbs.

3,200 lbs.

3,500 lbs.

3,700 lbs.

4"

2"

2,500 lbs.

3,100 lbs.

3,700 lbs.

4,000 lbs.

4,000 lbs.

5"

2-1/2"

3,200 lbs.

3,900 lbs.

4,000 lbs.

4,000 lbs.

4,000 lbs.

6"

3"

3,800 lbs.

4,000 lbs.

4,000 lbs.

4,000 lbs.

4,000 lbs.

Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

Swift Lift
Anchor
Tons x
Length

4 Tons
x
9-1/2"
Long

4 Tons
x
19"
Long

Tensile Safe Working Load Per Anchor

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

10"

15"

20"

24"

30"

3-3/4"

1-7/8"

2,500 lbs.

3,000 lbs.

3,300 lbs.

3,400 lbs.

3,500 lbs.

4"

2"

2,600 lbs.

3,200 lbs.

3,500 lbs.

3,700 lbs.

3,800 lbs.

5"

2-1/2"

3,300 lbs.

4,000 lbs.

4,400 lbs.

4,600 lbs.

4,700 lbs.

6"

3"

4,000 lbs.

4,800 lbs.

5,300 lbs.

5,500 lbs.

5,700 lbs.

7"

3-1/2"

4,700 lbs.

5,600 lbs.

6,200 lbs.

6,500 lbs.

6,600 lbs.

8"

4"

5,300 lbs.

6,400 lbs.

7,000 lbs.

7,400 lbs.

7,600 lbs.

3-3/4"

1-7/8"

3,500 lbs.

4,300 lbs.

4,900 lbs.

5,300 lbs.

5,800 lbs.

4"

2"

3,800 lbs.

4,600 lbs.

5,300 lbs.

5,700 lbs.

6,200 lbs.

5"

2-1/2"

4,700 lbs.

5,700 lbs.

6,600 lbs.

7,100 lbs.

7,800 lbs.

6"

3"

5,700 lbs.

6,900 lbs.

7,900 lbs.

8,000 lbs.

8,000 lbs.

7"

3-1/2"

6,600 lbs.

8,000 lbs.

8,000 lbs.

8,000 lbs.

8,000 lbs.

8"

4"

7,600 lbs.

8,000 lbs.

8,000 lbs.

8,000 lbs.

8,000 lbs.

Actual Corner Distance

Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

28

11/12

Swift Lift System

Swift Lift
Anchor
Tons x
Length

8 Tons
x
13-3/8"
Long

8 Tons
x
26-3/4"
Long

Swift Lift System

Swift Lift Anchor Effective Tensile Capacity in Thin Walls


Tensile Safe Working Load Per Anchor

Effective
Wall
Thickness
2de

Actual
Edge
Distance
de

12"

18"

24"

36"

45"

4-3/4"

2-3/8"

4,000 lbs.

4,800 lbs.

5,400 lbs.

6,000 lbs.

6,100 lbs.

5"

2-1/2"

4,200 lbs.

5,100 lbs.

5,700 lbs.

6,300 lbs.

6,400 lbs.

6"

3"

5,100 lbs.

6,100 lbs.

6,800 lbs.

7,500 lbs.

7,600 lbs.

7"

3-1/2"

5,900 lbs.

7,100 lbs.

8,000 lbs.

8,800 lbs.

8,900 lbs.

Actual Corner Distance

8"

4"

6,800 lbs.

8,100 lbs.

9,100 lbs.

10,100 lbs.

10,200 lbs.

10"

5"

8,500 lbs.

10,200 lbs.

11,400 lbs.

12,600 lbs.

12,700 lbs.

12"

6"

10,200 lbs.

12,200 lbs.

13,700 lbs.

15,100 lbs.

15,200 lbs.

4-3/4"

2-3/8"

5,800 lbs.

7,000 lbs.

8,000 lbs.

9,600 lbs.

11,200 lbs.

5"

2-1/2"

6,100 lbs.

7,400 lbs.

8,500 lbs.

10,100 lbs.

11,800 lbs.

6"

3"

7,300 lbs.

8,900 lbs.

9,500 lbs.

12,100 lbs.

14,100 lbs.

7"

3-1/2"

8,500 lbs.

10,300 lbs.

11,800 lbs.

14,200 lbs.

16,000 lbs.

8"

4"

9,700 lbs.

11,800 lbs.

13,500 lbs.

16,000 lbs.

16,000 lbs.

10"

5"

12,100 lbs.

14,800 lbs.

16,000 lbs.

16,000 lbs.

16,000 lbs.

12"

6"

14,500 lbs.

16,000 lbs.

16,000 lbs.

16,000 lbs.

16,000 lbs.

Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

Swift Lift
Anchor
Tons x
Length

20 Tons
x
19-3/4"
Long

Tensile Safe Working Load Per Anchor

Effective
Wall
Thickness
2de

Actual
Edge
Distance
de

10"

16"

24"

6-1/2"

3-1/4"

6,200 lbs.

7,500 lbs.

9,400 lbs.

10,300 lbs.

11,500 lbs.

7"

3-1/2"

6,700 lbs.

8,100 lbs.

10,100 lbs.

11,100 lbs.

12,400 lbs.

8"

4"

7,600 lbs.

8,900 lbs.

11,500 lbs.

12,600 lbs.

14,200 lbs.

10"

5"

9,500 lbs.

11,600 lbs.

14,400 lbs.

15,800 lbs.

17,700 lbs.

12"

6"

11,500 lbs.

14,000 lbs.

17,300 lbs.

19,000 lbs.

22,000 lbs.

14"

7"

13,400 lbs.

16,300 lbs.

20,100 lbs.

22,100 lbs.

24,800 lbs.

Actual Corner Distance


30"

42"

Safe Working Loadprovides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

To recalculate the safe working load when the anchor is used in a lower strength concrete, multiply the tabulated Safe
Working Load by the following reduction factors:

Concrete Strength

Reduction Factor

2,000 psi

.66

2,500 psi

.74

3,000 psi

.81

3,500 psi

.88

4,000 psi

.94

4,500 psi

1.00

11/12

29

Swift Lift System


Swift Lift Anchor Effective Tensile Capacity
Swift Lift System

When anchors are used in groups and in thin walls


Swift Lift
Anchor
Tons x
Length

2 Tons
x
6-3/4"
Long

2 Tons
x
11"
Long

Tensile Safe Working Load Per Anchor In Groups

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

18"

24"

30"

36"

48"

C = Actual Spacing Between Anchors

3"

1-1/2"

1,200 lbs.

1,500 lbs.

1,800 lbs.

1,900 lbs.

2,000 lbs.

3-1/4"

1-5/8"

1,300 lbs.

1,700 lbs.

1,900 lbs.

2,100 lbs.

2,200 lbs.

3-1/2"

1-3/4"

1,400 lbs.

1,800 lbs.

2,100 lbs.

2,300 lbs.

2,400 lbs.

4"

2"

1,600 lbs.

2,100 lbs.

2,400 lbs.

2,600 lbs.

2,700 lbs.

5"

2-1/2"

2,000 lbs.

2,600 lbs.

3,000 lbs.

3,200 lbs.

3,400 lbs.

6"

3"

2,500 lbs.

3,100 lbs.

3,600 lbs.

3,900 lbs.

4,000 lbs.

3"

1-1/2"

1,300 lbs.

1,700 lbs.

2,000 lbs.

2,300 lbs.

2,900 lbs.

3-1/4"

1-5/8"

1,400 lbs.

1,800 lbs.

2,200 lbs.

2,500 lbs.

3,100 lbs.

3-1/2"

1-3/4"

1,500 lbs.

1,900 lbs.

2,400 lbs.

2,700 lbs.

3,300 lbs.

4"

2"

1,700 lbs.

2,200 lbs.

2,700 lbs.

3,100 lbs.

3,800 lbs.

5"

2-1/2"

2,100 lbs.

2,800 lbs.

3,400 lbs.

3,900 lbs.

4,000 lbs.

6"

3"

2,600 lbs.

3,400 lbs.

4,000 lbs.

4,000 lbs.

4,000 lbs.

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

Swift Lift
Anchor
Tons x
Length

4 Tons
x
9-1/2"
Long

4 Tons
x
19"
Long

Tensile Safe Working Load Per Anchor In Groups

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

18"

24"

36"

48"

60"

3-3/4"

1-7/8"

1,600 lbs.

2,000 lbs.

2,800 lbs.

3,300 lbs.

3,500 lbs.

4"

2"

1,700 lbs.

2,200 lbs.

3,000 lbs.

3,600 lbs.

3,800 lbs.

5"

2-1/2"

2,100 lbs.

2,700 lbs.

3,800 lbs.

4,500 lbs.

4,700 lbs.

6"

3"

2,500 lbs.

3,300 lbs.

4,600 lbs.

5,400 lbs.

5,700 lbs.

7"

3-1/2"

3,000 lbs.

3,900 lbs.

5,300 lbs.

6,300 lbs.

6,700 lbs.

8"

4"

3,400 lbs.

4,400 lbs.

6,100 lbs.

7,200 lbs.

7,600 lbs.

3-3/4"

1-7/8"

1,600 lbs.

2,200 lbs.

3,200 lbs.

4,100 lbs.

5,000 lbs.

4"

2"

1,700 lbs.

2,300 lbs.

3,400 lbs.

4,400 lbs.

5,300 lbs.

5"

2-1/2"

2,200 lbs.

2,900 lbs.

4,300 lbs.

5,500 lbs.

6,600 lbs.

6"

3"

2,600 lbs.

3,500 lbs.

5,100 lbs.

6,600 lbs.

8,000 lbs.

7"

3-1/2"

3,100 lbs.

4,100 lbs.

6,000 lbs.

7,700 lbs.

8,000 lbs.

8"

4"

3,500 lbs.

4,500 lbs.

6,800 lbs.

8,000 lbs.

8,000 lbs.

C = Actual Spacing Between Anchors

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

30

11/12

Swift Lift System


Swift Lift Anchor Effective Tensile Capacity

Swift Lift
Anchor
Tons x
Length

8 Tons
x
13-3/8"
Long

8 Tons
x
26-3/4"
Long

Swift Lift System

When anchors are used in groups and in thin walls


Tensile Safe Working Load Per Anchor In Groups

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

18"

24"

36"

48"

60"

4-3/4"

2-3/8"

2,800 lbs.

3,600 lbs.

4,800 lbs.

5,300 lbs.

5,300 lbs.

5"

2-1/2"

2,900 lbs.

3,800 lbs.

5,000 lbs.

5,600 lbs.

5,600 lbs.

6"

3"

3,500 lbs.

4,500 lbs.

6,000 lbs.

6,700 lbs.

6,700 lbs.

7"

3-1/2"

4,100 lbs.

5,300 lbs.

7,100 lbs.

7,800 lbs.

7,800 lbs.

8"

4"

4,700 lbs.

6,000 lbs.

8,100 lbs.

8,900 lbs.

8,900 lbs.

10"

5"

5,900 lbs.

7,500 lbs.

10,100 lbs.

11,200 lbs.

11,200 lbs.

12"

5-1/2"

6,500 lbs.

8,300 lbs.

11,000 lbs.

12,300 lbs.

12,300 lbs.

4-3/4"

2-3/8"

2,900 lbs.

3,800 lbs.

5,600 lbs.

7,200 lbs.

8,500 lbs.

5"

2-1/2"

3,100 lbs.

4,000 lbs.

5,900 lbs.

7,600 lbs.

9,000 lbs.

6"

3"

3,700 lbs.

4,800 lbs.

7,100 lbs.

9,100 lbs.

10,800 lbs.

7"

3-1/2"

4,300 lbs.

5,700 lbs.

8,300 lbs.

10,600 lbs.

12,500 lbs.

8"

4"

4,900 lbs.

6,500 lbs.

9,400 lbs.

12,100 lbs.

14,300 lbs.

10"

5"

6,100 lbs.

8,100 lbs.

11,800 lbs.

15,100 lbs.

16,000 lbs.

12"

5-1/2"

6,700 lbs.

8,900 lbs.

13,000 lbs.

16,000 lbs.

16,000 lbs.

C = Actual Spacing Between Anchors

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

Swift Lift
Anchor
Tons x
Length

20 Tons
x
19-3/4"
Long

Tensile Safe Working Load Per Anchor In Groups

Effective
Wall
Thickness
2 de

Actual
Edge
Distance
de

20"

24"

33"

42"

60"

6-1/2"

3-1/4"

4,300 lbs.

5,200 lbs.

6,800 lbs.

8,300 lbs.

10,200 lbs.

7"

3-1/2"

4,700 lbs.

5,600 lbs.

7,400 lbs.

8,900 lbs.

11,000 lbs.

C= Actual Spacing Between Anchors

8"

4"

5,400 lbs.

6,300 lbs.

8,400 lbs.

10,200 lbs.

12,600 lbs.

10"

5"

6,700 lbs.

7,900 lbs.

10,500 lbs.

12,700 lbs.

15,700 lbs.

12"

6"

8,000 lbs.

9,500 lbs.

12,600 lbs.

15,300 lbs.

18,900 lbs.

7"

9,300 lbs.

11,100 lbs.

14,700 lbs.

17,800 lbs.

22,000 lbs.

14"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 4,500 psi normal weight concrete.

To recalculate the Safe Working Loads when the anchor is used in a lower strength concrete, multiply the tabulated Safe
Working Load by the following reduction factors:

Concrete Strength

Reduction Factor

2,000 psi

.66

2,500 psi

.74

3,000 psi

.81

3,500 psi

.88

4,000 psi

.94

4,500 psi

1.00

11/12

31

Swift Lift System


P53 Swift Lift Eye Anchor DS_P53
Swift Lift System

The Dayton Superior Swift LIft Eye Anchor (P53) is similar to the P52 anchor but has an eye at the foot to accept P60
Tension Bars. The P53 anchor is used primarily in thin sections, thin panels of lightweight concrete or shapes that must be
handled at concrete compressive strengths below 2,000 psi. P53 anchors are available in 1, 2, 4, 8 and 20-ton capacities
and each has its load rating embossed on the head.
4

To Order:
Specify: (1) quantity, (2) name, (3) system size, (4) length.

Example:
200, P53 Swift Lift Eye Anchors, 4 ton, 9-1/2" long.

P53 Swift Lift


Eye Anchor

P53 Swift Lift Eye Anchor for Lifting and Handling


The P53 Swift Lift Eye Anchor is designed for use with the P60 Tension Bar placed through the eye of the anchor. This
combination of Swift Lift Eye Anchor and P60 Tension Bar allows the anchors full rated tensile load to be developed in
thin, narrow wall applications. The anchor should be located at the center line of the wall. When two or more anchors are
required, the minimum spacing between anchors must be equal to the minimum panel width.
The combination of P53 Swift Lift Eye Anchor and P60 Tension Bar is an excellent system to use for lifting, handling and
setting precast columns.
dth

i
lW

e
Pan
m
m
u
u
nim inim er
Mi
M orn ce
C tan
Dis

Center line
of wall
and P53
Swift Lift
Eye
Anchor

m
imu idth
Min n W
m
lu
Co

CL

M
Col inim
um um
nD
ept
h

CL
L

L =  Anchor

Length

de = Actual Edge Distance


Wall Thickness

P53 Swift Lift Eye Anchor Selection Chart


Anchor Rated
Load
(tons)

Anchor Length
L

Minimum
Thickness or
Depth
de

Actual Edge
Distance
de

Minimum
Corner
Distance

Minimum
Panel Width

Tensile Safe
Working Load
per Anchor*
(lbs.)

2-1/2"

3"

1-1/2"

8"

16"

2,000

3-1/2"

3"

1-1/2"

4"

8"

4,000

4-3/4"

3-3/4"

1-7/8"

5"

10"

8,000

7-1/16"

4-3/4"

2-3/8"

7"

14"

16,000

20

9-7/8"

6-3/8"

3-3/16"

8-1/2"

17"

40,000

* Safe Working Load provides a factor of safety of approximately 4 to 1 in 2,000 psi normal weight concrete. The P53 Eye Anchor must be used in conjunction
with the P60 Tension Bar in order to develop its published rated working loads.
Note: Contact Dayton Superior Technical Service Department for safe working loads when the P53 Eye Anchor is used with straight lengths of rebar.

32

11/12

Swift Lift System


DS_P60

The Dayton Superior Swift Lift Tension Bar (P60) is designed to be used with the P53 Eye Anchor in order for the eye anchor
to develop its published rated working loads. See P60 sizes and dimensions below.

To Order:
Specify: (1) quantity, (2) name, (3) anchor size.

Example:
200, P60 Swift Lift Tension Bar, 10-ton anchor.

P60 Swift Lift Tension Bar

P60 Swift Lift Tension Bar Dimensions


Anchor
Rated
Load

Grade 60
Rebar
Size

Rebar
Overall
Length

Standard

.306" Wire

40"

14"

#3

24"

5"

#5

24"

#6

48"

20

#9

156"

(Tons)

A
Maximum

3/4"

7 -1 /2 "

1-1/8"

6 -1 /4 "

10"

1-7/8"

9 -1 /2 "

15"

2-1/4"

1 2 -1 /2 "

20"

3"

Note: Wire style is for use with 1 ton P53 Eye Anchors only.

P60 Rebar Style

14"

P60 Wire Style

P60 Swift Lift Tension Bar Installation


The proper installation of a tension bar is as follows:
1. Place the tension bar through the eye of the anchor in such a manner that the tension bar contacts the bottom of
the eye.
2. Make certain the legs of the tension bar are equal on either side of the anchor.
3. Wire the tension bar into position so that the tension bar stays in contact with the bottom of the eye. (See
sketch below.)
DO NOTattempt to use field-bent bars as a replacement for the Dayton Superior P60 Tension Bar. Field bending may
result in an improperly shaped tension bar, an incorrect radius and/or a cracked bar. A problem such as this can cause
the field-bent tension bar to fail prematurely.

Right

11/12

Wrong

33

Swift Lift System

P60 Swift Lift Tension Bar

Swift Lift System


P54 Swift Lift Throw-Away Recess Plug DS_P54
Swift Lift System

3" for 9/16"


Diameter Anchors
3-3/4" for 3/4"
Diameter Anchors

The Dayton Superior P54 Recess Plug is fabricated from high-density


polyethylene plastic in two sizes (2-ton and 4-ton) to accommodate the
P52 Swift Lift Anchor. The two-piece design snaps together around the
head of the anchor to securely grasp the anchor. Tabs on the recess plug
provide a convenient method to nail the assembly to the form. Built-in
retainers allow a P59 Shear Bar to clip to the recess plug and be held in
P54 Swift Lift Recess Plug
correct position. The P54 recess plug is designed to properly position the
anchor below the surface of the concrete. This allows easy patching
To Order:
of the recess and prevents surface staining from exposed steel.
Specify: (1) quantity, (2) name, (3) anchor size.
Warning: The P54 recess plug is designed to be used with the P52
insert and P59 shear bar combination. Failure to use these components in this combination may result in concrete spalling and/or premature failure.

Example:
200, P54 Swift Lift Recess Plugs, 4-ton anchor.

Anchor Foot

Anchor
Head

Anchor
Foot

P52 Swift
Lift Anchor

1. Assemble the P54 Recess Plug by placing the head


of the P52 Swift-Lift Anchor inside two halves of the
recess plug. Then snap the two halves together. It is
very difficult to assemble the unit with the foot of the
anchor inside the P54 Recess Plug and still get the two
halves to close together correctly. If the two halves of
the P54 Recess Plug do not fit closely together, it could
be because the anchor is in upside down. In such a
case, reverse the anchor and try again.

2. A correctly assembled P54 Recess Plug and P52 Swift


Lift Anchor.

3. Attach the assembled P54 Recess Plug and anchor to the


4.
form work in its predetermined location with the recess
plug seam in the vertical position. Use common (not double
headed) nails in the upper three tabs of the recess plug. The
plug and anchor assembly can also be attached to the form
work by using a 2-ton stud and wingnut if desired. Provide
bar supports around the anchor, as shown, to prevent
displacement during the casting process.

34

Slip the preformed shear bar on the P54 Recess Plug,


as shown. The receiving tabs of the P54 Recess Plug
will correctly position the shear bar. Usually, additional
support wiring is not needed to hold the shear bar in
place. However, prudent users will provide an additional
wire tie or two, to make certain the shear bar will not
dislodge during concrete placement. Wire tie the P52
Swift-Lift Anchor to reinforcing steel, as shown.

11/12

Swift Lift System


DS_P56

The Dayton Superior P56 Swift Lift Narrow Recess Plug is designed for use in thin-wall conditions, such as the top edge
of highway safety barriers. The recess plug is bolted to the form using a P63 stud and P64 wing nut combination and it
correctly positions the anchor below the surface of the concrete. P56 recess plugs are fabricated from nitrile butadiene and
are ideal for conditions requiring temperature or oil resistance.
T

To Order:
Specify: (1) quantity, (2) name, (3) anchor size.

Example:
Z

P56 Swift Lift


Narrow Recess Plug

200, P56 Swift Lift Narrow Recess Plugs, 4-ton anchor.

P56 Swift Lift


Narrow Recess Plug

Diameter

Swift Lift Narrow Recess Plug Dimensions


Z

Swift Lift
Anchor

Diameter
of
Recess Plug

Dimension
Z

Dimension
T

Dimension
B

2-3/8"

1-3/16"

1-21/32"

1-11/32"

3"

1-7/16"

2-1/32"

1-23/32"

3-3/4"

1-13/16"

2-3/4"

2-9/32"

4-3/4"

2-5/16"

3-11/32"

2-15/16"

20 Tons

6-3/8"

3-1/8"

4-15/16"

4-7/16"

Note: The diameter of the narrow recess plug is the same as the diameter of
the round recess plug.

P56R Swift Lift Round Recess Plug


The Dayton Superior P56 Swift Lift Round Recess Plug is fabricated from nitrile butadiene and ideal for use in conditions
requiring temperature or oil resistance. The plug must use the P63R Attachment Stud and P66R Attachment Nut. This plug
can not be attached to the form with either a Holding Plate or Magnetic Setting Plate. Dimensions of the recess plug are
slightly smaller than the standard P56 PL urethane plug. This recess is available by special order.

Swift Lift Round Recess Plug Dimensions

Diameter

11/12

Swift Lift
Anchor

Diameter
of
Recess Plug

Depth
"Z"

2.375

1.188

2.918

1.514

3.661

1.875

4.659

2.375

20 Tons

6.375

3.063

35

Swift Lift System

P56 Swift Lift Narrow Recess Plug

Swift Lift System


P56PL Swift Lift Plus Recess Plug

DS_P56PL

Swift Lift System

The Dayton Superior P56PL Swift Lift Plus Recess Plug is manufactured from highgrade elastomeric, thermal set urethane to provide improved tear, heat and chemical
resistance. The versatile, reusable plug utilizes a variety of accessories to provide
installation and stripping ease in many different applications. P56PL recess plugs are
available for 1, 2, 4 and 8-ton system sizes. See dimensions of P56PL Recess Plug in
P52 information.
Fixed
Nut
Free
Running
Nut

P56PL Swift Lift Plus Recess Plug

To Order:

Holding
Stud
With
Wing Nut
P63PL

Specify: (1) quantity, (2) name, (3) anchor size.

Example:
200, P54PL Swift Lift Plus Recess Plugs, 4-ton anchor.
Coil Wing
Nut P64PL

Holding Plate
P68PL

Holding Plate
(Optional)
P68PL
Stud Plate
P67PL
Tapped
Plate P66PL

Recess Plug
P56PL

Recess Plug
P56PL

Recess Plug
P56PL
Swift Lift
Anchor REF

Swift Lift
Anchor REF

Swift Lift
Anchor REF

P56PL Swift Lift Plus Recess Plug Typical Installations

P57 Swift Lift Steel Recess Plug


P58 Swift Lift Rubber Ring DS_P58

DS_P57

The Dayton Superior P57 Swift Lift Steel Recess Plug is designed for
permanent or semi-permanent attachment to repetitive-use precast
forms, such as battery molds, steel forms that have a collapsible
stripping feature, etc. The recess plug is drilled and tapped for easy
attachment to the form or may be held in place by a magnetic plate,
tack welded or glued. Available in 1, 2 and 4 ton only.
The P58 Swift Lift Rubber Ring is placed on the shaft of the anchor and
seats in the recess plug to hold the anchor firmly in the recess plug. It is
recommended that when the P57 recess plug is used, the anchor end be
supported to prevent dislodging (See sketch below).
P57 Swift
Lift Steel
Recess Plug

P57 Swift Lift Steel Recess Plug

P58 Swift Lift Rubber Ring


for Steel Recess Plug

Tie Wire To Nearby


Reinforcing Steel

To Order:
Specify: (1) quantity, (2) name, (3) anchor size.

Example:
Form
Face

36

P58 Swift Lift


Rubber Ring

200, P57 Swift Lift Steel Recess Plugs, 4 ton


anchor and 400 P58 Swift Lift Rubber Rings for
4-ton anchors.

11/12

P61 Swift Lift Setting Plate, P62


Countersunk Screw

No Obstruction for Screeding

The Dayton Superior P61 Swift Lift Setting Plate and P62
Countersunk Screw combination provide an easy method of
placing a Swift Lift Anchor into the surface of a flat panel without
obstructing the screeding process. The P61 setting plate is available
in two sizes, a 4" unit for use with 4-ton anchors and a 5" unit for
use with 8-ton anchors. The P62 screw is available in two sizes to
match the setting plates. The 4-ton setup uses a 3/4" long, 5/16"
18 NC thread screw and the 8-ton setup uses a 3/4" long, 7/16" 14
NC thread screw.DS_P61_P62

Anchor

Setting
Plate With
Countersunk
Screw
Tapped
Plate

Rubber
Recess
Plug

To Order:
Specify: (1) quantity, (2) name, (3) anchor size.

Example:
P62 Swift Lift
Countersunk Screw

P61 Swift Lift Setting


Plate

200, P61 Swift Lift Setting Plates and 200, P62


Countersunk Screws for 4-ton anchors.

P63 Swift Lift Stud, P64 Swift Lift Wing Nut

DS_P63_P64
The Dayton Superior P63 Swift Lift Stud and P64 Wing Nut combination is used to set P56 Narrow Recess Plugs. Available in two
sizes, 5/16" 18 NC threads for use with the 1-ton anchor and 7/16" 14 NC threads for use with 2, 4, 8 and 20-ton P56 anchors.

Note: The P63 Stud


and P64 Wing Nut are
not interchangeable
with the P56PL Recess
Plug accessories.

P63 Swift Lift Stud

To Order:
Specify: (1) quantity, (2) name, (3) size.

Example:
P64 Swift Lift
Wing Nut

200, P63 Swift Lift Studs and 200 P64


Swift Lift Wing Nuts, 7/16" dia.

P63PL Swift Lift Plus Holding Stud, P64PL Swift Lift Plus Wing Nut
The Dayton Superior P63PL Swift Lift Plus Holding Stud is a 3/8" diameter, coil threaded stud with a fixed wing nut and a
free-running wing nut used with the P66PL threaded plate to quickly attach the P56PL recess plug to the formwork. The
holding stud is inserted through the form and threaded into the threaded plate. Complete the anchor installation by
screwing the free-running wing nut tightly against the form. DS_P63PL_P64PL
The P64PL Wing Nut has 3/8" diameter coil thread and is available as a replacement nut for the P63PL Holding Stud.
Fixed

Thread

Free

Reduced
Diameter
Threaded Nose

6"

Swift Lift Anchor

Holding
Stud

P64PL Swift Lift


Plus Wing Nut

P63PL Swift Lift Plus


Holding Stud

Tie Swift Lift Anchor to reinforcing


steel to ensure anchor support
during concrete placement.

To Order:
Specify: (1) quantity, (2) name.

Example:
200, P63PL Swift Lift Plus Holding Studs.

11/12

37

Swift Lift System

Swift Lift System

Swift Lift System


P66 Swift Lift Tapped Plate DS_P66
Swift Lift System

The Dayton Superior Swift Lift Tapped Plate (P66) is tapped for either a 5/16" or 7/16" diameter NC thread and used to install the
P56 Narrow Recess Plug. This is a replacement plate only; it can be used with the P63 Stud or with NC bolts supplied by others.

To Order:

5/16" or 7/16" Dia.


NCThreads

Specify: (1) quantity, (2) name, (3) thread size.

Example:
100, P66 Swift Lift Tapped Plate, 7/16" dia. NC
thread.

P66 Swift Lift


Tapped Plate

P66PL Swift Lift Plus Threaded Plate


P67PL Swift Lift Plus Stud Plate DS_P66PL_P67PL_P68PL
P68PL Swift Lift Plus Holding Plate
The Dayton Superior P66PL Swift Lift Plus Threaded Plate, P67PL Stud Plate and P68PL Holding Plate are working parts used
to install the P56PL Recess Plug in various applications. These working parts are available in 1, 2, 4 and 8-ton system sizes.

To Order:
P66PL Swift Lift
Plus Threaded
Plate

Specify: (1) quantity, (2) name, (3) system size.

Length

Example:
P68PL Swift Lift Plus
Holding Plate

100, P66PL Swift Lift Plus Threaded Plate, 4-ton


system.

P67PL Swift Lift


Plus Stud Plate

P69 Swift Lift Magnetic Setting Plate DS_P69


The Dayton Superior P69 Swift Lift Magnetic Setting Plates are available to firmly set P56PL Recess Plugs in metal, precast
concrete forms. The reusable magnetic setting plate eliminates holes drilled in the metal forms for anchor setting purposes.

To Order:
Specify: (1) quantity, (2) name, (3) system size.
NOTE: One piece recess plug with magnets
imbedded in top available, contact DSC
Customer Service.

Example:
20, P69 Swift Lift Magnetic Setting Plates, 4-ton
system.

P69 Swift Lift Magnetic Setting


Plate

P104 Magnetic OnePiece Swift Lift Recess

DS_P104

The Dayton Superior P104 Magnetic OnePiece Swift Lift Recess is a urethane recess plug with magnets embedded in the
face for easy attachment to metal forms. This provides the precaster the option for a one-piece unit versus P56PL Swift Lift
Recess Plug and P69 Magnetic Setting Plate. It is available in 2, 4 and 8-ton sizes.
Diameter

To Order:
Specify: (1) quantity, (2) name, (3) system size.

Example:
Z

38

20, P104 Magnetic OnePiece Swift Lift Magnetic


Recess, 8-ton system.

11/12

Fleet-Lift System
Fleet-Lift System Overview

Fleet-Lift System

The Dayton Superior Fleet-Lift System comprises two main parts, the Fleet-Lift Anchor and the Fleet-Lift Ring Clutch. The
design of the system allows loads to be applied from any direction.

Fleet-Lift System Components


The selection of the proper capacity Fleet-Lift System is based on several factors, such as:

Size of precast element

Rigging configuration

Compressive strength of concrete at initial lift

Embedment depth of anchor

Edge distance

Anchor spacing

Direction of applied load

Use of tension bars, shear bars or shear plates.

Each Fleet-Lift anchor is stamped with its MAXIMUM safe working load and the letters DSC, which identifies it as a
Dayton Superior Corporation product. The hole near the top of the anchor head is designed to receive the appropriate
size ring clutch.
Both the anchor and ring clutch are rated with a safe working load. The safe working load of the anchor is based on a
factor of safety of 4 to 1 (ultimate to safe). Each ring clutch has a Load Range embossed on it, which shows the anchors it
can be used with. A factor of safety of 5 to 1 is applied to the highest load in the range for each size of ring clutch.
To use, simply push the ring clutch onto the head of the anchor that is located in a recess created by a Fleet-Lift recess plug.
Once the ring clutch is pushed onto the head of the anchor, the ring clutchs curved bolt is pushed through the hole in the
anchor. This locks the ring clutch and anchor into a single unit ready to lift the precast concrete element.
To disengage the anchor and ring clutch, simply pull the curved bolt free of the anchor this allows the ring clutch to be
easily removed form the head of the anchor.
Dayton Superior recommends a minimum 3/4" cover between the bottom of an anchor and the concrete surface. This
minimum recommended concrete cover is to prevent anchor corrosion.

11/12

39

Fleet-Lift System
P91S Fleet-Lift Ring Clutch DS_P91S
The P91S Fleet-Lift Ring Clutch consists of a clutch body, a curved bolt and a high strength bail.
Installation and release is safe and simple. After the clutch is inserted over the anchor head
and into the recess, the curved bolt is rotated into the closed position.

A
B

Rotation of the standard bail is a full 360 . Once engaged and supporting four hundred
pounds of load, the ring clutch cannot be released.
E
G

To Order:
Fleet-Lift System

Specify: (1) quantity, (2) name, (3) product code,


(4) system size.

Example:
9, P91S Fleet-Lift Ring Clutches, FL002S, 4/6-ton units.
P91S Fleet-Lift Ring Clutch Selection Chart
Safe Working
Load
(Tons)

Load
Range
(Tons)

Product
Code

2-3

FL001S

3-3/4"

2-3/8"

10-1/2"

3"

7"

3"

1"

4-6

FL002S

4-3/4"

2-5/8"

12-1/2"

4"

8-1/4"

3-1/2"

1-1/2"

10

8-10

FL003S

5-7/8"

3"

17-3/4"

5-7/8"

11"

4-1/2"

2-1/8"

22

12.5-22

FL004S

4-3/4"

3-5/8"

21-1/4"

8-1/4"

14-7/8"

4-3/4"

2-7/8"

P91S Fleet-Lift Ring Clutch

Installation of P91S Ring Clutch

The P91S Ring Clutch is located directly


over the head of a Fleet-Lift Anchor.

40

The ring clutch is pushed down onto the


anchor head and the curved bolt is rotated
through the engagement hole of the anchor
and locked into position. The process of
engaging anchor and ring clutch is completed
in seconds.

11/12

Fleet-Lift System
P91NC Fleet-Lift Cable Bail Ring Clutch DS_P91NC
The Fleet-Lift Ring Clutch with cable bail can be the solution to many difficult lifting and rotating-tovertical situations. Cable bails can also be used to replace bent or damaged bails on standard clutches.

D
E

The engagement, use and release of the Cable Bail Ring Clutch are similar in operation to the
standard Ring Clutch with the fixed bail.
Once the load is relaxed, the ring clutch can be easily released.
P91NC Fleet-Lift Cable Bail Ring Clutch Selection Chart

Load Range
(Tons)

Product
Code

2-3

FL001NC

30"

9/16"

2-3/4"

2-3/8"

4-3/8"

4-6

FL002NC

36"

3/4"

3-11/16"

3-38"

6-5/8"

10

8-10

FL003NC

36"

1"

5-5/16"

3-3/4"

7-1/8"

Fleet-Lift System

Safe Working
Load
(Tons)

Safe working load provides a factor of safety of approximately 5 to 1.

To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) system size.

Example:

9, P91NC Fleet-Lift Cable Bail Ring Clutches, FL002NC, 4/6-ton units.

P91NC Fleet-Lift
Cable Bail Ring Clutch

Inspection and Maintenance of Ring Clutches


The Fleet-Lift P91S and P91NC Ring Clutches may be subject to wear, misuse, overloading and many other factors that may
affect a Ring Clutchs safe working load.
The users must establish a program for inspection of their Ring Clutches based on their frequency of use. Inspections
should consist of the following:
Safe Working
Load

Load
Range

3. If evidence of heat application is found, the clutch must be destroyed.

2-3

0.562"

4. Check for bent or twisted bails.

4-6

0.781"

5. Check for worn or bent curved bolt.

10

8-10

0.921"

1. Determine the general overall condition and wear.


2. Make certain the bail can rotate freely in all directions.

6. Check for worn or deformed main clutch body.


7. Check for enlarged engagement slot.

(Tons)

(Tons)

Note: Destroy all units if found to be worn, damaged, bent or


twisted. The proper method for use in destroying a Ring Clutch is to
cut off and remove the bail. No repair or welding on Fleet-Lift Ring
Clutches is permitted.

During inspection of the clutch body, if the engagement slot is found


to exceed dimension W, remove the ring clutch from service and destroy it.

Additional Inspection of Cable Bails


Before every use, inspect the wire cable for:
1. Damage or extreme wear
2. Bends or kinks
3. Fraying or loosening of outer strands
4. Squeezes in the free length
5. Squeezes in the support area
6. Cable swelling
7. Cable ruptures in excess of four runners in three diameters of the cable length, six runners in six diameters of the cable
length or sixteen runners in 30 diameters of cable length.
If the cable is damaged, it must be replaced. Dayton Superior can arrange for cable replacement. Contact the nearest
Dayton Superior Technical Assistance for information and cost.

11/12

41

Fleet-Lift System
P92 Fleet-Lift Erection Anchor DS_P92
Fleet-Lift P92 Erection Anchors are specifically designed for horizontal to vertical
edge lifts and handling of thin-walled precast concrete elements. Two steel
protrusions or ears on the head of the anchor provide protection against
concrete spalling. These protrusions restrict the ring clutch rotation during
lateral pulls. As a result, lateral forces are transmitted directly to the edge of the
anchor instead of the concrete.

E D

Fleet-Lift System

The body of the Erection Anchor is shaped to allow full reinforcement for secure
support and spall-free rotation.
P92 Erection Anchors are available plain or hot-dipped galvanized.

To Order:

Specify: (1) quantity, (2) name, (3) anchor style, (4)


corrosion resistance, if required.

Example:
200, P92 Fleet-Lift Erection Anchors, FL047, hotdipped galvanized.

H
J

P92 Fleet-Lift Erection Anchor


P92 Fleet-Lift Erection Anchor Dimensions
Safe Working
Load

Product Code

FL047

FL048

FL049*

3-3/4"

(Tons)

2-3/8"

3-3/8"

3-3/16"

4-7/16"
5-3/4"

2"

8"

3/8"

1-13/16"

2-1/2"

10-7/16"

5/8"

2-1/2"

13-1/4"

3/4"

3-1/8"

4"

5/8"

1"

1/2"

3/8"

3/4"

1-1/4"

3/4"

7/16"

1"

1-3/4"

3/4"

5/8"

Note: Dimension X is distance from surface of concrete to anchor.

Shear Reinforcement

Direction of Lift

Stress is caused during the edge lift of a panel, making supplemental reinforcement
around the anchor necessary in thin panels. Fleet-Lift P98S Shear Bars are designed
expressly for this purpose. Place the shear bar in the side notch of the anchor as
shown in the sketch at right.
Reference P98S Shear Bar section for more information.
Note: A properly installed P98S Shear Bar is required to develop the shear safe working loads
shown in the chart on the following page.

Typical P92 Fleet-Lift Erection


Anchor/ Shear Bar Application

Tension Reinforcement
The P92 Dayton Superior Fleet-Lift Erection Anchor is manufactured with a steel
tension pin that resists pullout during normal erection situations. The safe working
load chart, on the following page, list two sets of tension values. If the higher safe
working load is used, the anchor must be properly reinforced using the P98T Tension
Reinforcement. The tension bar should be placed through the lower hole of the
anchor.
Reference P98T Tension Reinforcement section for more information.
Typical P92 Fleet-Lift Erection
Anchor/Tension Bar Application

42

11/12

Fleet-Lift System
P92 Fleet-Lift Erection Anchor Tension and Shear Capacities
P92 Fleet-Lift
Erection Anchor

Product
Code

Precast Concrete
Panel Thickness

2-ton x 8" long

FL047

4" Min.

1,650 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL047

5"

1,875 lbs.

3,350 lbs.

4,000 lbs.

2-ton x 8" long

FL047

6"

2,125 lbs.

3,850 lbs.

4,000 lbs.

2-ton x 8" long

FL047

7"

2,400 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL047

8"

2,700 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL047

9"

2,925 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL047

10"

3,275 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL047

11"

3,575 lbs.

4,000 lbs.

4,000 lbs.

Shear Safe Working


Load with Shear Bar

Tension Safe Working Tension Safe Working


Load with Anchor Only Load With Tension Bar

2-ton x 8" long

FL047

12"

4,000 lbs.

4,000 lbs.

4,000 lbs.

4-ton x 10-7/16" long

FL048

5-1/2" Min.

2,400 lbs.

4,700 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

6"

3,075 lbs.

5,050 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

7"

3,250 lbs.

5,825 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

8"

3,425 lbs.

6,600 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

9"

3,825 lbs.

7,350 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

10"

4,250 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

11"

4,650 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL048

12"

5,050 lbs.

8,000 lbs.

8,000 lbs.

8-ton x 13-1/4" long

FL049

7-1/2" Min.

4,000 lbs.

7,500 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL049

8"

4,200 lbs.

7,775 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL049

9"

4,550 lbs.

8,300 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL049

10"

4,950 lbs.

8,800 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL049

11"

5,050 lbs.

10,000 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL049

12"

5,175 lbs.

11,300 lbs.

16,000 lbs.

Fleet-Lift System

(ton x length)

Notes:
1. Safe Working Loads are based on approximately a 4 to 1 factor of safety in 3,500 psi normal weight concrete.
2. Install shear bar and tension bar, when required, per instructions on preceding page.

11/12

43

Fleet-Lift System
P92P Fleet-Lift Erection Anchor with Shear Plate

DS_P92P

The P92P Fleet-Lift Erection Anchor with Shear Plate is designed specifically for edge
tilting precast concrete elements from the horizontal to a vertical position. An integral
shear plate eliminates any possibility of forgetting to install a required shear bar.

As on other Fleet-Lift Erection Anchors, two steel protrusions or ears at the head of
the anchor provide protection against concrete spalling. These ears restrict the ring
clutch rotation during lateral pulls. As a result, lateral forces are transmitted directly to
the edge of the anchor instead of the concrete.
Fleet-Lift System

The body of the erection anchor is shaped to allow full reinforcement for secure support
and spall-free rotation.
P92P Erection Anchors are available plain or hot-dipped galvanized.

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.

Example:
200, P92P Fleet-Lift Erection Anchor with Shear
Plate, FL148, hot-dipped galvanized.

Safe Working
Load

Product Code

FL147

FL148

FL149

2-1/2"

3/4"

3"

2-1/2"

1-1/4"

3"

3"

1-5/8"

3-1/2"

(Tons)

P92P Fleet-Lift Erection Anchor


with Shear Plate

Anchor dimensions not shown are the same as the P92 Erection Anchor of
the same load range.

Shear Reinforcement
Stress is caused during the edge lifting of a precast panel, making supplemental
reinforcement around the anchor necessary in thin panels. The Fleet-Lift P92P
Erection Anchor with integral Shear Plate is designed expressly for this purpose.
Install the anchor so that the shear plate is opposite the direction of lift.

Tension Reinforcement
The P92P with Shear Plate Fleet-Lift Erection Anchor is manufactured with a
steel tension pin that resists pullout during normal erection situations. The safe
working load chart on the following page lists two sets of tension values. If the
higher safe working load is used, the anchor must be properly reinforced using
the P60T Tension Bar. The tension bar should be placed through the lower hole.

44

Typical P92P
FleetLift
Erection
Anchor with
Shea Plate
Application

Direction of Lift

Typical P92P FleetLift


Erection Anchor Shear
Plate/Tension Bar
Application

11/12

Fleet-Lift System
P92P Fleet-Lift Erection Anchor with Shear Plate Capacities

P92 Fleet-Lift
Erection Anchor

Product
Code

Precast Concrete
Panel Thickness

2-ton x 8" long

FL147

3-1/2" Min.

1,450 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL147

4"

1,625 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL147

5"

2,050 lbs.

3,350 lbs.

4,000 lbs.

2-ton x 8" long

FL147

6"

2,350 lbs.

3,750 lbs.

4,000 lbs.

2-ton x 8" long

FL147

7"

2,625 lbs.

3,850 lbs.

4,000 lbs.

2-ton x 8" long

FL147

8"

2,850 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL147

9"

3,050 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL147

10"

3,225 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL147

11"

3,425 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL147

12"

3,675 lbs.

4,000 lbs.

4,000 lbs.

4-ton x 10-7/16" long

FL148

4" Min.

2,150 lbs.

3,450 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

5"

2,625 lbs.

4,250 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

6"

3,100 lbs.

5,075 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

7"

3,525 lbs.

5,825 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

8"

3,925 lbs.

6,600 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

9"

4,275 lbs.

7,350 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

10"

4,600 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

11"

4,900 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL148

12"

5,150 lbs.

8,000 lbs.

8,000 lbs.

8-ton x 13-1/4" long

FL149

6" Min

4,000 lbs.

5,580 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

7"

4,250 lbs.

6,870 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

8"

4,475 lbs.

7,775 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

9"

4,725 lbs.

8,300 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

10"

4,950 lbs.

8,800 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

11"

5,200 lbs.

10,000 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL149

12"

5,450 lbs.

11,300 lbs.

16,000 lbs.

Fleet-Lift System

(ton x length)

Shear Safe Working Tension Safe Working Tension Safe Working


Load with Shear Plate Load with Anchor Only Load With Tension Bar

Notes:

1) Safe Working Loads are based on approximately a 4 to 1 factor of safety in 3,500 psi normal weight concrete.
2) FL449 uses 8-10T P99 Recess and P91 Ring Clutch.

11/12

45

Fleet-Lift System
P92DP Fleet-Lift Erection Anchor with Shear Plate and Shear Pin DS_P92DP
The Dayton Superior P92DP Fleet-Lift Erection Anchor with a Shear Plate and
a Shear Pin is similar to the P92P anchor with the addition of a shear pin. By
welding a solid shear pin opposite the shear plate, the anchor can resist shear
loads in both directions.

Solid
Shear Pin

Installation and Primary Shear Loading


The P92DP anchor is set in the form with the shear plate in the down position
to resist the primary shear load.
Fleet-Lift System

Secondary Shear Loading


When the panel is placed on an A frame or is required to be rotated 180,
the addition of the shear pin works with the shear plate to resist the shear
load in the opposite direction of the shear plate. The shear pin helps to
protect the concrete from spalling when the shear loads are applied in a
secondary direction.

F
C

P92DP Erection Anchors are available either plain or hot-dipped galvanized steel.

To Order:

Specify: (1) quantity, (2) name, (3) product code, (4)


corrosion resistance, if required.

Shear
Plate

Example:
200, P92DP Fleet-Lift Erection Anchor with Shear Plate/
Pin, FL744, 4/6-ton system size, hot-dipped galvanized.

Load Range

Product Code

FL647

FL648

FL649

(Tons)

P92DP Fleet-Lift Erection Anchor with


Shear Plate/Pin

2-1/2"

3/4"

3"

1/4"

1/2"

2-3/4"

2-1/2"

1-1/4"

3"

3/4"

3/4"

2-7/8"

3"

1-5/8"

3-1/2"

3/4"

3/4"

2-7/8"

Anchor dimensions not shown are the same as the P92 Erection Anchor of the same load range.

Tension Reinforcement
The P92DP Fleet-Lift Erection Anchor is manufactured with a steel tension pin that resists pullout during normal erection
situations. The safe working load chart on the following page lists two sets of tension values. If the higher safe working
load is used, the anchor must be properly reinforced using the P60T Tension Bar. The tension bar should be placed through
the lower hole of the anchor.

Direction of Lift for


Primary Shear

46

Direction of Lift for


Secondary Shear

11/12

Fleet-Lift System

P92 Fleet-Lift
Erection Anchor

Product
Code

Precast
Concrete Panel
Thickness

Shear Safe
Working Load for
Primary Shear

Shear Safe
Working Load for
Secondary Shear

Tension Safe
Working Load
Anchor Only

Tension Safe
Working Load
With Tension Bar

2-ton x 8" long

FL647

3-1/2" Min.

1,450 lbs.

1,150 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL647

4"

1,625 lbs.

1,300 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL647

5"

2,050 lbs.

1,650 lbs.

3,350 lbs.

4,000 lbs.

2-ton x 8" long

FL647

6"

2,350 lbs.

1,750 lbs.

3,750 lbs.

4,000 lbs.

2-ton x 8" long

FL647

7"

2,625 lbs.

1,875 lbs.

3,850 lbs.

4,000 lbs.

2-ton x 8" long

FL647

8"

2,850 lbs.

2,100 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL647

9"

3,050 lbs.

2,275 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL647

10"

3,225 lbs.

2,450 lbs.

4,000 lbs.

4,000 lbs.

2-ton x 8" long

FL647

4,000 lbs.

(ton x length)

11"

3,425 lbs.

2,575 lbs.

4,000 lbs.

2-ton x 8" long

FL647

12"

3,675 lbs.

2,950 lbs.

4,000 lbs.

4,000 lbs.

4-ton x 10-7/16" long

FL648

4" Min.

2,150 lbs.

1,725 lbs.

3,450 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

5"

2,625 lbs.

2,100 lbs.

4,250 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

6"

3,100 lbs.

2,475 lbs.

5,075 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

7"

3,525 lbs.

2,825 lbs.

5,825 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

8"

3,925 lbs.

3,150 lbs.

6,600 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

9"

4,275 lbs.

3,425 lbs.

7,350 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

10"

4,600 lbs.

3,675 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

11"

4,900 lbs.

3,925 lbs.

8,000 lbs.

8,000 lbs.

4-ton x 10-7/16" long

FL648

12"

5,150 lbs.

4,125 lbs.

8,000 lbs.

8,000 lbs.
16,000 lbs.

8-ton x 13-1/4" long

FL649

6" Min.

4,000 lbs.

3,200 lbs.

5,580 lbs.

8-ton x 13-1/4" long

FL649

7"

4,250 lbs.

3,400 lbs.

6,870 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL649

8"

4,475 lbs.

3,575 lbs.

7,775 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL649

9"

4,725 lbs.

3,775 lbs.

8,300 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL649

10"

4,950 lbs.

3,975 lbs.

8,800 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL649

11"

5,200 lbs.

4,150 lbs.

10,000 lbs.

16,000 lbs.

8-ton x 13-1/4" long

FL649

12"

5,450 lbs.

4,350 lbs.

11,300 lbs.

16,000 lbs.

Fleet-Lift System

P92DP Fleet-Lift Erection Anchor with Shear Plate and Shear Pin Capacities

Notes:

1) Safe Working Load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2) Install anchors as shown on preceding page to develop safe working loads in chart.

11/12

47

Fleet-Lift System
P92FE Fleet Lift Forged Erection Anchor DS_P92FE
The Dayton Superior P92FE Forged Erection Anchor is specifically designed to provide greater lifting
capacities for horizontal to vertical edge lifts. The anchors are forged to provide 20% greater safe working
loads. The head of the anchor is designed with two protrusions or "ears" on the head of the anchor which
provide protection against concrete spalling. These protrusions restrict the ring clutch rotation during lateral
pulls. As a result, lateral forces are transmitted directly to the edge of the anchor instead of the concrete.
The P92FE Forged Erection Anchor utilizes the Fleet P91S or Fleet P91NC lifting hardware and the P99 Recess Plugs.
P92FE Forged Erection Anchors are available in plain or hot-dipped galvanized finishes.
Fleet-Lift System

P92FE Capacity

Product Code
(Plain)

Product Code
(Galvanized)

3-Ton

126748

127518

6-Ton

143420

143421

10-Ton

143422

143423

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.

Example:
200, P92FE Fleet-Lift Forged Erection Anchors,
#126748, hot-dipped galvanized.
P92FE Forged Erection Anchor
Ton x Length

3-ton x 8"

6-ton x 10-3/8"

10-ton x 12-3/4"

Slab Thickness

Insert Height

Minimum
Edge Distance

Minimum
Corner
Distance

Shear
SafeWorking
Loadwith
Shear Bar

Tension Safe
Working Load
Anchor Only

Tension Safe
Working Load
with Tension
Bar

4" Min.

8"

2"

12"

1,390lbs.

2,500lbs.

6,000lbs.

5"

8"

2-1/2"

12"

1,680lbs.

3,130lbs.

6,000lbs.

6"

8"

3"

12"

1,980lbs.

3,760lbs.

6,000lbs.

7"

8"

3-1/2"

12"

2,300lbs.

4,380lbs.

6,000lbs.

8"

8"

4"

12"

2,630lbs.

5,010lbs.

6,000lbs.

9"

8"

4-1/2"

12"

2,980lbs.

5,640lbs.

6,000lbs.

10"

8"

5"

12"

3,340lbs.

6,000lbs.

6,000lbs.

11"

8"

5-1/2"

12"

3,720lbs.

6,000lbs.

6,000lbs.

12"

8"

6"

12"

4,110lbs.

6,000lbs.

6,000lbs.

5-1/2"Min.

10-3/8"

2-3/4"

16"

2,840lbs.

4,720lbs.

12,000lbs.

6"

10-3/8"

3"

16"

3,030lbs.

5,150lbs.

12,000lbs.

7"

10-3/8"

3-1/2"

16"

3,430lbs.

6,010lbs.

12,000lbs.

8"

10-3/8"

4"

16"

3,840lbs.

6,870lbs.

12,000lbs.

9"

10-3/8"

4-1/2"

16"

4,270lbs.

7,730lbs.

12,000lbs.

10"

10-3/8"

5"

16"

4,710lbs.

8,590lbs.

12,000lbs.

11"

10-3/8"

5-1/2"

16"

5,010lbs.

9,450lbs.

12,000lbs.

12"

10-3/8"

6"

16"

5,540lbs.

10,310lbs.

12,000lbs.

7 1/2"

12-3/4"

3-3/4"

19"

4,180lbs.

7,920lbs.

20,000lbs.

8"

12-3/4"

4"

19"

4,420lbs.

8,440lbs.

20,000lbs.

9"

12-3/4"

4-1/2"

19"

4,920lbs.

9,500lbs.

20,000lbs.

10"

12-3/4"

5"

19"

5,430lbs.

10,560lbs.

20,000lbs.

11"

12-3/4"

5-1/2"

19"

5,950lbs.

11,610lbs.

20,000lbs.

12"

12-3/4"

6"

19"

6,490lbs.

12,670lbs.

20,000lbs.

Safe Working Load provides a factor of safety approximately 4 to 1 in 3,500 psi normal weight concrete.

48

11/12

Fleet-Lift System
P92FEW Fleet Lift Forged Erection Anchor with Sheer Plate DS_P92FEW
P92FEW
Capacity

Product Code
(Plain)

Product Code
(Galvanized)

3 Ton

129473

139577

6 Ton

143424

143425

10 Ton

143426

143427

Fleet-Lift System

The P92FEW Forged Erection Anchor with Shear Plate eliminates the need for a shear bar. The P92FE
and P92FEW anchors are stocked in a plain finish and can be galvanized locally.

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.

Example:
200, P92FEW Fleet-Lift Forged Erection Anchors,
#139577, hot-dipped galvanized.

P92FEW Fleet Forged Erection Anchor


Ton x Length

3 Ton x 8"

6 Ton x 10-3/8"

10 Ton x 12-3/4"

Slab Thickness

Minimum Edge
Distance

Minimum
Corner Distance

Shear Safe
Working Load
with Shear Plate

Tension Safe
Working Load
Anchor Only

Tension Safe
Working Load
with Tension
Bar

4"

2"

12"

1,800lbs

6,000lbs

6,000lbs

5"

2-1/2"

12"

2,300lbs

6,000lbs

6,000lbs

6"

3"

12"

2,800lbs

6,000lbs

6,000lbs

7"

3-1/2"

12"

3,400lbs

6,000lbs

6,000lbs

8"

4"

12"

4,000lbs

6,000lbs

6,000lbs

9"

4-1/2"

12"

4,400lbs

6,000lbs

6,000lbs

10"

5"

12"

4,800lbs

6,000lbs

6,000lbs

11"

5-1/2"

12"

5,200lbs

6,000lbs

6,000lbs

12"

6"

12"

5,700lbs

6,000lbs

6,000lbs

5-1/2"

2-3/4"

16"

3,100lbs

10,000lbs

12,000lbs

6"

3"

16"

3,250lbs

10,500lbs

12,000lbs

7"

3-1/2"

16"

3,700lbs

11,500lbs

12,000lbs

8"

4"

16"

4,040lbs

12,000lbs

12,000lbs

9"

4-1/2"

16"

4,600lbs

12,000lbs

12,000lbs

10"

5"

16"

5,000lbs

12,000lbs

12,000lbs

11"

5-1/2"

16"

5,500lbs

12,000lbs

12,000lbs

12"

6"

16"

6,100lbs

12,000lbs

12,000lbs

7-1/2"

3-3/4"

19"

4,600lbs

17,500lbs

20,000lbs

8"

4"

19"

4,800lbs

18,000lbs

20,000lbs

9"

4-1/2"

19"

5,450lbs

19,000lbs

20,000lbs

10"

5"

19"

6,100lbs

20,000lbs

20,000lbs

11"

5-1/2"

19"

6,800lbs

20,000lbs

20,000lbs

12"

6"

19"

7,600lbs

20,000lbs

20,000lbs

Safe Working Load provides a factor of safety approximately 4 to 1 in 3,500 psi normal weight concrete.

11/12

49

Fleet-Lift System
P92FEWDP Forged Erection Anchor with Shear Plate and Secondary Shear Pin
The P92FEWDP Forged Erection Anchor with Shear Plate is specifically designed to provide greater lifting
capacities for horizontal to vertical edge lifts. By welding a solid shear pin opposite the shear plate, the
anchor can resist shear loads in both directions. The anchors are forged to provide 20% greater safe working
loads. The P92FEWDP eliminates the need for a shear bar on the primary and secondary shear loading.

Fleet-Lift System

Due to the anchor being forged, it does not depend on welds


or thread engagement to develop its safe working load.
Forging provides maximum safety with its advantageous
material structure. This allows the anchor to easily meet the
OSHA requirement of 4 to 1 factor of safety.

P92FEWDP

Product Code
(Plain)

Product Code
(Galvanized)

3 Ton

142881

MTO

6 Ton

142882

MTO

10 Ton

142883

MTO

PRODUCT APPLICATION:

The P92FEWDP Forged Erection Anchor with Shear Plate and Secondary Shear Pin is designed specifically for
edge tilting precast concrete elements from the horizontal to vertical position. When the panel is placed on
an A frame or is required to be rotated 180, the addition of the shear pin works with the shear plate to
resist the shear load in the opposite direction of the shear plate. The shear pin helps to protect the concrete from spalling
when the shear loads are applied in a secondary direction.

PRODUCT FEATURES AND BENEFITS:


The P92FEWDP has two steel protrusions or ears at the head of the
anchor which provides protection against concrete spalling. These
ears restrict the ring clutch rotation during lateral pulls. As a result,
lateral forces are transmitted directly to the edge of the anchor instead
of the concrete.
The P92FEWDP Forged Erection Anchor utilizes the Fleet P91S or Fleet
P91NC lifting hardware and the P99 Recess Plugs.

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) finish.

Example:
200, P92FEWDP 3-Tonx8" Fleet-Lift Forged
Erection Anchor with Shear Plate and Secondary
Shear Pin, 142881, plain finish.

The P92FEWDP Forged erection Anchors are available in a plain finish.

INSTALLATION:
The P92FEWDP anchor is set in the form with the shear plate in the down position to resist the primary shear load.
Shear Safe
Working Load
Secondary
Shear

Tension Safe
Working Load
Anchor Only

Tension Safe
Working Load
with Tension Bar

Product Code
142881

4"

1,800 lbs

1,390 lbs

6,000 lbs

6,000 lbs

3 Ton x 8"

142881

8"

4,000 lbs

3,000 lbs

6,000 lbs

6,000 lbs

142881

12"

5,700 lbs

4,425 lbs

6,000 lbs

6,000 lbs

142882

5-1/2"

3,100 lbs

2,560 lbs

10,000 lbs

12,000 lbs

142882

8"

4,040 lbs

3,660 lbs

12,000 lbs

12,000 lbs

142882

12"

6,100 lbs

5,600 lbs

12,000 lbs

12,000 lbs

6 Ton x 10-3/8"

10 Ton x 12-3/4"

Slab Thickness

Shear Safe
Working Load
Primary Shear

Ton x Length

142883

7-1/2"

4,600 lbs

3,630 lbs

17,500 lbs

20,000 lbs

142883

10"

6,100 lbs

4,900 lbs

20,000 lbs

20,000 lbs

142883

12"

7,600 lbs

6,520 lbs

20,000 lbs

20,000 lbs

Safe working load provides a factor of safety approximately 4 to 1 in 3.500 psi normal weight concrete

50

11/12

Fleet-Lift System
P92H Fleet-Lift Two-Hole Erection Anchor DS_P92H, DS_P92HP
P92HP Fleet-Lift Two-Hole Erection Anchor with Shear Plate
Fleet-Lift Two-Hole Erection Anchors combine the strength, spall
resistance and high tension performance of the P92 Erection Anchor.

A
A

The P92H Two-Hole Erection Anchor was designed for use where the
lift direction applies a tension load ONLY to the anchor. A properly
installed P98T Tension Bar is always required when using this erection
anchor. For shear applications the P98S Shear Bar is designed to fit
over the P92H. The design of the shear bar allows it to fit over the top
edge of the anchor. It is placed in the top notch and secured so that it
bears tightly against the bottom of the notch. Accurate placement of
the shear bar provides for spall-free edge lifting.

Fleet-Lift System

B
F

The P92HP Two-Hole Erection Anchor was designed for use


where the lift direction applies both a shear and tension load to
the anchor. As with the P92H anchor, a properly installed P98T
Tension Bar is always required when using the P92HP Erection
Anchor. Shear loading for this anchor is resisted by the P92HP
anchors integral shear plate.

Both the P92H and P92HP Erection Anchors are available in 2, 4, 6 or


P92HP Fleet-Lift
P92H Fleet-Lift
8-ton capacities. In addition, they are available in either plain or hotTwo-Hole Erection Anchor Two-Hole Erection Anchor
dipped galvanized finish.
with Shear Plate
(Tension Loadings ONLY)
(Shear and Tension Loading)

To Order:

Specify: (1) quantity, (2) name, (3) product code,


(4) corrosion resistance, if required.

Example:
200, P92H Fleet-Lift Two-Hole Erection Anchor,
FL075, hot-dipped galvanized.
P92H
Fleet-Lift
Two-Hole Erection
Anchor

Product
Code

P92HP
Two-Hole Erection
Anchor
w/ Shear Plate

Product
Code

(ton x length)

(ton x length)

2-ton x 4-1/4" long

FL403

2"

4-1/4"

3/8"

2-ton x 4-1/4" long

FL423

2-1/2"

3"

1/4"

2-ton x 8-1/4" long

FL903

2"

8-1/4"

3/8"

2-ton x 8-1/4" long

FL403L

2-1/2"

3"

1/4"

4-ton x 7-7/8" long

FL075

2-1/2"

7-7/8"

5/8"

4-ton x 7-7/8" long

FL275

2-1/2"

3"

3/8"

4-ton x 10-7/8" long

FL975

2-1/2"

10-7/8"

5/8"

4-ton x 10-7/8" long

FL175L

2-1/2"

3"

3/8"

8-ton x 13-1/4" long

FL185L

3-3/4"

13-1/4"

3/4"

8-ton x 13-1/4" long

FL285L

3"

3-1/2"

3/8"

Anchor dimensions not shown are the same as the P92 Erection Anchor of the same load range.

Shear Reinforcement
Stress is caused during the edge lifting of a precast
concrete panel, making supplemental reinforcement
around the anchor necessary in thin panels. The FleetLift P92HP Erection Anchor with integral Shear Plate is
designed expressly for this purpose. Install the anchor
so that the shear plate is opposite the direction of lift.

Direction of Lift

Tension Reinforcement
The P92HP Fleet-Lift Erection Anchor with Shear
Plate must be properly reinforced using the P60T
Tension Bar. The tension bar should be placed
through the lower hole.

11/12

Typical P92HP Fleet-Lift


Two-Hole Erection Anchor with
Shear Plate Application

Typical P92HP Fleet-Lift


Two-Hole Erection Anchor
with Shear Plate/Tension Bar
Application

51

Fleet-Lift System
P92H Fleet-Lift Two-Hole Erection Anchor and
P92HP Fleet-Lift Two-Hole Erection Anchor with Shear Plate Capacities
P92H or P92HP
Fleet-Lift Two-Hole
Erection Anchor

Product
Code

Precast Concrete
Panel Thickness

P92HP With
Shear Plate Safe
Working Load

3-1/2" Min.

1,325 lbs.

4"

1,525 lbs.

5"

1,525 lbs.

(ton x length)

Fleet-Lift System

2-ton x 4-1/4" long


2-ton x 4-1/4" long
2-ton x 4-1/4" long

FL403
FL423
FL403
FL423
FL403
FL423

P92H or P92HP
Tension Safe
Working Load With
Tension Bar
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.
4,000 lbs.

2-ton x 4-1/4" long

FL403
FL423

6"

1,750 lbs.

4,000 lbs.
4,000 lbs.

2-ton x 4-1/4" long

FL403
FL423

7"

1,900 lbs.

4,000 lbs.
4,000 lbs.

2-ton x 4-1/4" long


2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
2-ton x 8-1/4" long
4-ton x 7-7/8" long
4-ton x 7-7/8" long
4-ton x 7-7/8" long
4-ton x 7-7/8" long
4-ton x 7-7/8" long
4-ton x 7-7/8" long
4-ton x 10-7/8" long
8-ton x 13-1/4" long

FL403
FL423
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL903
FL403L
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL075
FL275
FL975
FL175L
FL185L
FL285L

4,000 lbs.
4,000 lbs.
4,000 lbs.
4"
1,650 lbs.
4,000 lbs.
4,000 lbs.
5"
1,875 lbs.
4,000 lbs.
4,000 lbs.
6"
2,125 lbs.
4,000 lbs.
4,000 lbs.
7"
2,400 lbs.
4,000 lbs.
4,000 lbs.
8"
2,700 lbs.
4,000 lbs.
4,000 lbs.
9"
2,925 lbs.
4,000 lbs.
4,000 lbs.
10"
3,275 lbs.
4,000 lbs.
4,000 lbs.
11"
3,575 lbs.
4,000 lbs.
4,000 lbs.
12"
3,975 lbs.
4,000 lbs.
8,000 lbs.
5-1/2" Min.
2,025 lbs.
8,000 lbs.
8,000 lbs.
6"
2,250 lbs.
8,000 lbs.
8,000 lbs.
7"
2,600 lbs.
8,000 lbs.
8,000 lbs.
8"
3,000 lbs.
8,000 lbs.
8,000 lbs.
9"
3,375 lbs.
8,000 lbs.
8,000 lbs.
10"
3,750 lbs.
8,000 lbs.
Same panel thickness and SWLs as FL048
Same panel thickness and SWLs as FL148
Same panel thickness and SWLs as FL049
Same panel thickness and SWLs as FL149
8"

2,075 lbs.

Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Dayton Superior recommends the use of the P90HP Fleet-Lift Anchor when shear loads will be encountered.

52

11/12

Fleet-Lift System
P92S Fleet-Lift Sandwich Panel Erection Anchor DS_P92S, DS_P92SP
P92SP Fleet-Lift Sandwich Panel Erection Anchor with Shear Plate
The Fleet-Lift Sandwich Panel Erection Anchor is designed to erect precast,
insulated sandwich panels with a minimum loss of insulation. The anchor
uses standard Fleet-Lift recess plugs and ring clutches.

The design of the anchor allows it to distribute anchor loads evenly to both
concrete wythes. This is accomplished by the use of two specially bent rebars
per sandwich panel anchor. The sandwich panel erection anchor, with its
unique anchor head shape, in combination with the two bent rebars, transfers
both the anchors shear and tension loads evenly into each of the concrete
wythes.

Place one bent rebar through the anchors top hole and the second rebar
through the anchors bottom hole. The rebar extend from the anchor into the
top and bottom wythe of concrete. The two specially bent rebar must be used
with the sandwich panel erection anchor to achieve the safe working loads
shown.

P92S Fleet-Lift Sandwich Panel


Erection Anchor

The P92SP Sandwich Panel Erection Anchor is similar in design and


actioto the P92S anchor, and has a built-in shear plate. The shear plate
improves shear capacity when used in the 2", 3" and 4" thick wythes.

A
F

Both the P92S and P92SP anchors are available in plain or hot-dipped
galvanized finish.
To
p
In

Bo

yt

tto

su

he

lat

Parallel to Thickness

io

yt

he

P92SP Sandwich Panel


Erection Anchor with Shear Plate

To Order:

Perpendicular to Thickness

Specify: (1) quantity, (2) name, (3) product code,


(4) finish.

Example:

Typical Sandwich Panel


Erection Anchor Application

200, P92S Fleet-Lift Sandwich Panel Erection


Anchor, FL220, hot-dipped galvanized.

Anchor
Tonnage

Product
Code

Shear
Plate

4-ton
4-ton
4-ton
8-ton
8-ton
10-ton
10-ton
10-ton
10-ton

FL220
FL077
FL230
FL184
FL284
128242
128243
127351
127350

Yes
No
Yes
No
Yes
No
No
Yes
Yes

4"
6"
6"
6"
6"
7"
8"
7"
8"

3-3/4"
3-3/4"
3-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"
4-3/4"

2-3/8"
4-3/8"
4-3/8"
4-3/8"
4-3/8"
5"
6"
6"
6"

2-1/16"
1-13/16"
1-13/16"
3-3/8"
3-3/8"
3-3/8"
3-3/8"
3-3/8"
3-3/8"

5/8"
5/8"
5/8"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"

3"
3"
3"
8"
8"

2"
2"
3-1/2"
3"
3"

11/12

53

Fleet-Lift System

The P92S Sandwich Panel Erection Anchor is designed for use with 2", 3" and
4" thick insulated sandwich panels.

Fleet-Lift System

P92 Fleet-LIft Sandwich Panel Reinforcing Bars


Anchor
Tonnage
4-ton
8-ton
10-ton

Anchor Product
Code
FL077
FL220
FL184
FL284
127351 127350

3"

Rebar
#4 Grade 60 x 34" overall
#5 Grade 60 x 42" overall
#5 Grade 75 x 50" overall

2"

Fleet-Lift System

3"
Min. Radius
Detail A

3" x 2" x 3" Panel

5/8"
Overall
Length

4"

8"

2"

30
32"

Detail A

3"

30
3"

Rebar for 2" x 2" x 2" Panel

Rebar for 3" x 2" x 3",


2" x 2" x 4", 3" x 3" x 3" and
3" x 4" x 3" Panels
2" x 3" x 3" Panel

Fleet Lift Sandwich Panel Erection Anchor Safe Working Loads


Anchor
Tonnage

For
Anchor

4-ton
4-ton
8-ton
8-ton
8-ton
8-ton
10-ton
10-ton

FL077
FL077
FL184
FL184
FL284
FL284
127351
127350

Concrete
Compressive
Strenth
4,500 psi
3,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi
4,500 psi

Insulated
Panel
Thickness
2" x 2" x 4"
3" x 2" x 3"
3" x 2" x 3"
2" x 2" x 4"
4" x 2" x 2"
3" x 2" x 3"
3" x 3" x 3"
3" x 4" x 3"

Shear Parallel
to Thickness
3,300lbs
3,425lbs
3,850lbs
3,450lbs
4600lbs
4,400lbs
4,700lbs
4,400lbs

Shear
Perpendicular
to Thickness
8,000lbs
8,000lbs
9,900lbs
10,500lbs
9,870lbs
8,800lbs
10,900lbs
9,200lbs

Tension
8,000lbs
8,000lbs
16,000lbs
16,000lbs
15,400lbs
15,400lbs
20,000lbs
20,000lbs

Safe working loads based on 4:1 SF


Minimum edge distance is 20
Must use proper tension bar to achieve loads

54

11/12

Fleet-Lift System
P92AH Fleet-Lift Erection Anchor with 45 Head with Shear Plate
The Dayton Superior P92AH Fleet-Lift Erection Anchor with
45 Head and Shear Plate is designed for use when the
lifting edge is beveled at a 45 angle. The factory installed
shear plate eliminates the need for any additional shear
reinforcement.

C
45

Installation
To install the P92AH anchor, position the anchor a minimum
of 3/4" and a maximum of 1-1/2" clear of the casting
bed. This can be accomplished using any of the standard
recess members. After the anchor has been secured in
place, tension reinforcement may be added, if desired.
After the concrete has set, removal of the edge form and
recess member will expose the head of the anchor for easy
attachment of the lifting eye.

Tension Reinforcement
Due to the geometry of the anchor the loads shown in the
table should not be exceeded, even if additional tension
reinforcement is present.
P92AH Erection Anchors are available plain, or hot-dipped
galvanized.

Fleet-Lift System

P92AH Fleet-Lift Erection Anchor


with 45 Head with Shear Plate

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.

Example:
200, P92AH, Fleet-Lift Erection Anchor with 45
head, FL454, hot-dipped galvanized.

DS_P92AH

Chamfer
45

3/4" Min. to 1-1/2" Max.

Shear Lift

Tension Lift

P92AH
Fleet-Lift
Erection Anchor

Product
Code

Precast
Concrete
Panel
Thickness

Shear Safe
Working
Load for
Shear

2-ton x 8-1/2" long

FL452

5" Min.

1,750 lbs.

2,650 lbs.

2,650 lbs.

2-ton x 8-1/2" long

FL452

6"

2,150 lbs.

3,850 lbs.

3,850 lbs.

4-ton x 11" long

FL454

6" Min.

2,400 lbs.

5,200 lbs.

5,200 lbs.

4-ton x 11" long

FL454

8"

3,500 lbs.

6,200 lbs.

6,200 lbs.

8-ton x 13-3/4" long

FL458

8" Min.

3,500 lbs.

7,500 lbs.

7,500 lbs.

(ton x length)

Tension Safe Tension Safe


Working
Working
Load Anchor
Load with
Only
Tension Bar

2"

8-1/2"

3/8"

3-1/2"

2-1/2"

11"

5/8"

4"

3/4"

5-3/8"

3-3/4" 13-3/4"

Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Safe Working Load is based on the anchor being located in the panel so that the shear plate is 3/4" minimum to 1-1/2" maximum from
casting surface.
3. Panel will not hang plumb, as the panel thickness, center of gravity and anchor location will determine the exact angle at which the panel
will hang.
4. Due to the design of this anchor, DO NOT attempt to use this anchor at loads higher than shown in this table even with a properly
installed tension bar.
5. Anchor dimensions not shown are the same as the P92P Erection Anchor with Shear Plate of the same load range.

11/12

55

Fleet-Lift System
P93 Fleet-Lift L-Anchor DS_P93
The Dayton Superior P93 Fleet-Lift L-Anchor is a very efficient anchor. This anchor is used for both stripping and erection
carrying tension and/or shear loads (except for edge shear in thin panels). The L-Anchor produces
exceptionally high pullout strength for its size, due to its foot design.
A

The L-Anchor can be placed on the face, back, or thicker panel edge allowing for back-stripping
and their rotation from horizontal to vertical.
The P93 anchor is available in plain or hot-dipped galvanized finish. This anchor requires the use
of the 2/5-ton range ring clutch and the 2/3-ton load range recess plug.
Fleet-Lift System

To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) finish.
D

Example:

200 P93 Fleet-Lift L-Anchor, FL050, hot-dipped finish.

P93 Fleet-Lift Product Precast Concrete Minimum Edge or


L-Anchor
Code
Panel Thickness
Corner Distance
(ton x length)

1-ton x 4" long

FL050

5" Min.

P93 Fleet-Lift L-Anchor


Shear Safe
Tension Safe
Working Load Working Load

12"

2,000 lbs.

2,000 lbs.

1-1/4"

4"

1-7/16" 3/16"

Notes:
1. Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
2. Anchor is not designed for use in thin edge shear conditions.
3. Anchor must use FL051 (P99) Reusable Recess Plug

P94 Fleet-Lift T-Anchor


The P94 Fleet-Lift T-Anchor is a versatile anchor available in many
sizes and lengths. Its high pullout strength allows it to be used
for back-stripping and erection. T-Anchors can be placed on
the face, back or edge of panels allowing for back-stripping and
rotation from horizontal to vertical.
P94 anchors are available in plain or hot-dipped galvanized finish.

P94 Fleet-Lift
L-Anchor
(ton x length)

Precast
Concrete
Product Minimun
Code
Panel
Thickness

To Order:
Specify: (1) quantity, (2) name,
(3) product code, (4) finish.

Example:
200, P94 Fleet-Lift T-Anchors,
FL850, hot-dipped galvanized.

Minimum
Edge or
Corner
Distance

Shear
Safe
Working
Load

Tension
Safe
Working
Load

2-ton x 4" long

FL110

4-3/4"

8"

4,000 lbs.

4,000 lbs. 1-1/4"

2-ton x 5-1/2" long

FL059

5-7/8"

11"

4,000 lbs.

4-ton x 4-1/4" long

FL848

4-5/8"

8-1/2"

4-ton x 4-3/4" long

FL849

5-1/8"

9-1/2"

4-ton x 5-1/4" long

FL850

5-5/8"

4-ton x 5-3/4" long

FL851

4-ton x 6-1/4" long

FL852

4-ton x 6-3/4" long


4-ton x 7-1/4" long

D
A
C

4,000 lbs. 1-1/4" 5-1/2"

3/8"

1/2"

5,500 lbs.

5,500 lbs. 1-1/2" 4-1/4"

5/8"

1/2"

7,100 lbs.

7,100 lbs. 1-1/2" 4-3/4"

5/8"

1/2"

10-1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 5-1/4"

5/8"

1/2"

6-1/8"

11-1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 5-3/4"

5/8"

1/2"

6-5/8"

12-1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 6-1/4"

5/8"

1/2"

FL853

7-1/8"

13-1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 6-3/4"

5/8"

1/2"

FL854

7-5/8"

14-1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 7-1/4"

5/8"

1/2"

8,000 lbs.

8,000 lbs. 1-1/2" 7-3/4"

5/8"

1/2"

12,000 lbs. 12,000 lbs. 2-1/2" 11-1/8"

5/8"

3/4"

7,950 lbs. 2-1/2" 6-1/8"

3/4"

3/4"

16,000 lbs. 16,000 lbs. 2-1/2" 11-1/8"

3/4"

3/4"

FL855

8-1/8"

15-1/2"

FL319*

11-1/2"

23"

8-ton x 6-1/8" long

FL055

6-1/8"

12-1/4"

8-ton x 11-1/8" long

FL119

11-3/4"

23"

56

1/2"

4-ton x 7-3/4" long

1.
2.
3.
4.

3/8"

6-ton x 11-1/8" long

7,950 lbs.

4"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,500 psi normal weight concrete.
Side notches are provided on 4-ton T-Anchors only.
No side notches are provided on 2, 6 and 8-ton T-Anchors.
Use 8-10T P99 Recess and P91 Ring Clutch with FL319*.

P94 Fleet-Lift
T-Anchor 4-ton

B
D

P94 Fleet-Lift
T-Anchor
2, 6 and 8-ton

11/12

Fleet-Lift System
P94H Fleet-Lift H-Anchor 2-Ton DS_P94H

3.3"

The Dayton Superior Fleet-Lift H-Anchor (P94H) is unique in design simplicity. It offers
exceptional strength for lifting and handling precast elements, yet can be used in panels
as thin as 3". The P94H anchor can be easily preset in the form or wet set after the
concrete has been poured. The H-Anchor is the strongest and most economical precast
lifting anchor available for back-stripping. H-Anchors are available in plain and hot-dipped
galvanized finish.
Load

2.3"

FL523

FL524
Fleet-Lift System

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required.

Example:
200, P94H Fleet-Lift H-Anchor, FL525,
hotdipped galvanized.

P94H Safe Working Load

Optional Reinforcement

Tension
Shear

Shear

Product
Code

Load
Range

Tension
Load
4:1 SF

Tension with
Reinforcement**
4:1 SF

Shear
Load
4:1 SF

Minimum
Edge
Distance

Ultimate
Mechanical
Strength

FL523

2 Ton

2,205lbs.

2,900lbs.

2,205lbs.

8"

16,000lbs.

FL524

2 Ton

3,255lbs.

4,000lbs.

3,255lbs.

10"

16,000lbs.

Safe Working Load provides a factor of safety of approximately 4 to 1. Table is based on a minimum concrete
compressive strength of 3,500 psi.
* When panel edge installation is required, use the H-Anchor or Two-Hole Anchor with a tension bar. Contact
Dayton Superior Technical Assistance for minimum tension reinforcement.
** #4 x 12" long placed directly at centerline and against bottom of hole. See sketches at left.

P94H Dimensions
Product
Code
Optional

Reinforcement

Resists Tension and Shear Loads

Minimum
Slab
Thickness

Weight
Each
B

2/3 Ton Ring Clutch System (2-Ton Anchor)


FL523

1.25"

2.30"

.35"

.56"

3"

.28 lbs.

FL524

1.25"

3.30"

.38"

1.44"

4"

.36 lbs.

P94H
H-Anchors
are available
galvanized.
FL525
.38"and hot-dipped
1.25"
4.30" in plain
1.44"
5"

FL529

11/12

1.25"

9.30"

.38"

1.44"

10"

.53 lbs.
1.38 lbs.

3/8"
3/8"

57

Fleet-Lift System
P94S Fleet-Lift S-Anchor DS_P94S

1-1/2"

The Dayton Superior P94S Fleet-Lift S-Anchor is a high-strength, hot forged anchor that can be wet
set" or used with the optional T41 Plastic base in face-lift applications. When the P94S anchor is
used with the Fleet-Lift high capacity ring clutches, safe working loads up to 20,000 pounds can be
realized. See the chart below for appropriate anchor lengths and concrete compressive strengths.
P94S anchors are available in plain and hot-dipped galvanized.

Insert
Height
5/8"

To Order:
Fleet-Lift System

Specify: (1) quantity, (2) name,


(3) product code, (4) finsih.

Example:
400, P94S Fleet-Lift S-Anchors, FL505
with hot-dipped galvanized finish.

1-7/8"

Type S

Type F

P94S Fleet-Lift
S-Anchor

P94S Fleet Lift S-Anchor


Anchor Tonnage
2.5
2.5
2.5
6
6
6
6
6
6
6
6
10
10
10

Length (L)
3-1/2"
4"
5-1/2"
3-7/8"
4-1/8"
4-7/8"
5-1/8"
5-7/8"
6-1/8"
6-7/8"
7-7/8"
5-1/2"
7"
10"

Width (A)
1-5/16"
1-5/16"
1-5/16"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2-5/8"
2-5/8"
2-5/8"

Thickness (B)
3/8"
3/8"
3/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
3/4"
3/4"
3/4"

Foot Diameter (C)


1-1/2"
1-1/2"
1-1/2"
1-7/8"
1-7/8"
1-7/8"
1-7/8"
1-7/8"
1-7/8"
1-7/8"
1-7/8"
2-7/8"
2-7/8"
2-7/8"

SWL Tension
3,900
4,400
4,510
5,000
5,370
6,560
6,970
8,250
8,700
10,070
12,000
8,500
12,500
20,000

Type
F/S
F/S
F
S
S
S
S
S
S
S
S
F
S
S

Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete Use FL062 Recess Member and FL002S Ring
Clutch (both 4-6T) with these anchors.

P95F Fleet-Lift Flat Foot Anchor

The Dayton Superior P95F Fleet-Lift Flat Foot Anchor is a versatile anchor that can be used
to back-strip and transport thin panels. This anchor may also be used to erect the panels.
The anchors safe working load may be increased by adding four 18" lengths of #4 rebar
as shown in the sketch.

To Order:

Specify: (1) quantity, (2) name, (3) product code.

Example:
200, P94F Fleet-Lift Flat Foot Anchor, FL058.

P95F Fleet-Lift Flat Foot Anchor

#4 x 18" Long

P95F Fleet-Lift Product


Code
Flat Foot Anchor

Precast
Concrete
Minimum
Panel
Thickness

Minimum
Edge or
Corner
Distance

Shear
Safe
Working
Load

Tension
Safe
Working
Load

Shear Safe Tension Safe


Working
Working
Load
Load
Reinforced Reinforced

2-ton x 2-3/4" long

FL058

3-7/8"

5-1/2"

1,325 lbs.

1,325 lbs.

4,000 lbs.

4,000 lbs.

1-1/4" 2-3/4"

3/8"

4"

2-ton x 3-3/8" long

FL400

4-1/2"

6-3/4"

1,875 lbs.

1,875 lbs.

4,000 lbs.

4,000 lbs.

1-1/4" 3-3/8"

3/8"

4"

3-ton x 3-3/4" long

FL157

3-7/8"

7-1/2"

2,350 lbs.

2,350 lbs.

6,000 lbs.

6,000 lbs.

1-1/2" 3-3/4"

1/2"

4"

Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.

58

11/12

Fleet-Lift System
P95P Fleet-Lift Plate Anchor DS_P95P

The Dayton Superior P95P Fleet-Lift Plate Anchor is manufactured with


a wide base designed to increase its pull-out capacity in concrete. The
wide base allows the anchor to have an increased safe working load.

P95P anchors are available in plain or hot-dipped galvanized finish.

C
D

P95P Fleet-Lift Plate Anchor

To Order:

Fleet-Lift System

The design of the anchor, with its wide base, permits four #4 rebar,
each 18" in length to be easily secured to the insert, as illustrated in
the sketch. The addition of the rebar increases the safe working load
of the anchor.

(FL043 only)

Specify: (1) quantity, (2) name, (3) product code,


(4) corrosion resistance, if required.

Example:
200, P95P Fleet-Lift Plate Anchor, FL847.
#4 x 18" Long

P95P Fleet-Lift
Plate Anchor

Product
Code

Precast
Concrete
Minimum
Panel
Thickness

Minimum
Edge or
Corner
Distance

2-ton x 2-1/4" long

FL128

3-3/8"

4-1/2"

950 lbs.

950 lbs.

4,000 lbs.

4,000 lbs.

4-ton x 3" long

FL846

4-1/8"

6"

3,575 lbs.

3,575 lbs.

6,000 lbs.

6,000 lbs.

4-ton x 3-1/2" long

FL847

4-5/8"

7"

4,700 lbs.

4,700 lbs.

7,000 lbs.

7,000 lbs.

1-1/2" 3-1/2"

5/8" 3-3/8"

4-ton x 4-3/8" long

FL044

5-5/8"

8"

4,725 lbs.

4,725 lbs.

8,000 lbs.

8,000 lbs.

1-1/2" 4-3/8"

5/8"

4"

8-ton x 6-7/8" long

FL043

8-1/4"

13-5/8"

10,850 lbs. 10,850 lbs. 11,750 lbs.

11,750 lbs.

2-1/2" 6-7/8"

3/4"

3"

Shear
Safe
Working
Load

Tension
Safe
Working
Load

Shear Safe Tension Safe


Working
Working
Load
Load
Reinforced Reinforced

1-1/4" 2-1/4"

3/8"

4"

1-1/2"

5/8" 3-3/8"

3"

Safe Working Load provides an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.
A minimum 3/4" of concrete is required below bottom of insert to achieve load.

P96 Fleet-Lift TwoHole Anchor DS_P96


The Dayton Superior P96 Fleet-Lift TwoHole Anchor is always used in conjunction with the Dayton Superior P98T Tension Bar. The
anchor has a bottom hole especially designed to accept the tension bar. Place the P98T Tension Bar through the bottom hole in such
a manner that the ends of the tension bar are pointing downward. Fasten the tension bar tight against the bottom side of the hole.
The tension bar distributes the tension forces, developed from the lifting process, deep into the precast concrete. This allows
the lifting of very thin and/or low concrete compressive strength panels.
Do not use the P96 Two-Hole Anchor in the following situations:
1. Without a correct size and located tension bar.
2. In the edge of thin panels where shear loads will be applied to the anchor.
D

NOTE: Tension reinforcement must be used with


Two Hole Anchors.

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required. See P98T
Fleet-Lift Tension Bar.

B
E
F
C

P96 Fleet-Lift
Two Hole Anchor

Example:
200, P96 Fleet-Lift Two-Hole Anchor, FL124.
P96 Fleet-Lift TwoHole Anchor
(ton x length)

Product
Code

Tension Safe Working Load


with Tension Bar

2-ton x 2-3/4" long


2-ton x 4" long

FL190
FL122

4,000lbs
4,000lbs

1-1/4"
1-1/4"

2-3/4"
4"

3/8"
3/8"

9/16"
3/4"

15/16"
7/8"

9/16"
9/16"

4-ton x 5-1/2" long

FL124

8,000lbs

1-1/2"

5-1/2"

5/8"

7/8"

1"

11/16"

8-ton x 7" long

FL125

16,000lbs

2-1/2"

7"

3/4"

1-3/16"

1-1/2"

1"

Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.

11/12

59

Fleet-Lift System
P96F Fleet-Lift Forged Two-Hole Anchor DS_P96F

Fleet-Lift System

The Dayton Superior P96F Fleet-Lift Forged Two-Hole Anchor is always used in conjunction
with the Dayton Superior P98T Tension Bar. The anchor has a bottom hole especially designed
to accept the tension bar. Place the P98T Tension Bar through the bottom hole in such a
manner that the ends of the tension bar are pointing downward. Fasten the tension bar tight
against the bottom side of the hole. The tension bar distributes the tension forces, developed
from the lifting process, deep into the precast concrete. This allows the lifting of very thin
and/or low concrete compressive strength panels. Do not use the P96F Two-Hole Anchor in
the following situations: 1) Without a correct size and located tension bar. 2) In the edge of
thin panels where shear loads will be applied to the anchor.

P96F Fleet-Lift
Forged TwoHole Anchor

To Order:
Specify: (1) quantity, (2) name, (3) product code,
(4) corrosion resistance, if required. See P98 Fleet-Lift Tension Bar.

Example:
200, P96F Fleet-Lift Forged Two-Hole Anchor, FL124.

P96 Fleet-Lift Two-Hole Anchor


(ton x length)

Product
Code

Tension Safe Working Load


with Tension Bar

22-ton

128946

44,000lbs

3.5"

11.25"

1.13"

2"

1.375"

1.75"

Safe working load is based on an approximate factor of safety of 4 to 1 in 3,500 psi normal weight concrete.

T110 Superior Lift System DS_T110


The Dayton Superior T110 Superior Lift Insert is a face lift insert and consists of a forged foot
anchor, 4-leg wire base and plastic void former. The insert utilizes the P91 Ring Clutch 8-10 T.
The T110 Superior Lift Inserts are shipped assembled, ready to go and are sized 18" less than
the panel thickness. The T110 can also be shipped unassembled.

To Order:
Specify: (1) quantity, (2) name, (3) Panel Thickness,
(4) bottom face exposed aggregate or form liner thickness.
T110 Superior Lift System

Example:
150, T110 Superior Lift Inserts, 9" Panel with " form liner panel.

Structural Panel
Thickness

Anchor
Length

Product Code for


Anchor Only

SWl Tension

SWL Sheer

5"
5.5"

3.625"
4.125"

----126538

6,875lbs
7,683lbs

7,362lbs
7,958lbs

6"

4.625"

126539

8,490lbs

8,535lbs

6.5"

5.125"

126541

9,298lbs

9,095lbs

7"

5.625"

126542

10,106lbs

9,641lbs

7.5"
8"
9"

6.125"
6.625"
7.625"

126544
126545
126548

10,914lbs
11,960lbs
12,000lbs

10,175lbs
10,748lbs
12,000lbs

10"
7.875"
126549
12,000lbs
12,000lbs
Safe working load provides approximate factor of safety of 4 to 1 in 3,500 psi normal
weight concrete

60

11/12

Fleet-Lift System
P98S Fleet-Lift Shear Bar DS_P98S
The Dayton Superior P98S Fleet-Lift Shear Bar is designed and manufactured especially for use with Fleet-Lift Erection Anchors.
It is a simple, easy to use, yet very efficient design that transfers shear forces from the erection process deeper into the edge
of a precast concrete panel. It is stronger and less expensive than a shear bar fabricated from reinforcing steel.
The design of the shear bar allows it to fit over the top edge of an erection anchor. It is placed in the top notch and
secured so that it bears tightly against the bottom of the notch. Accurate placement of the shear bar provides for spallfree edge lifts.
Fleet-Lift System

The P98S Shear Bar is available to fit 2, 4 and 8-ton Fleet-Lift Erection Anchors. Available in plain or hot-dipped galvanized finish.

Typical Shear Bar


Application

P98S Fleet-Lift Shear Bar


Shear Bar
Equal
Erection
Anchor

CL
Equal
Erection Anchor

Shear Bar

Top View

Minimum 3/4" Concrete Cover

Section View
Dimensions

To Order:

Anchor
Tonnage

Product
Code

Shear Bar
Diameter

Minimum
Panel
Thickness

2-3 ton

FL140

1/2"

4"

2-1/2"

13-7/8"

Example:

4-6 ton

FL141

1/2"

5-1/2"

3-5/16"

13-7/8"

8-10 ton

FL142

1/2"

7-1/2"

4-15/16"

13-7/8"

200 P98S Fleet-Lift Shear Bar, FL141, hotdipped


galvanized.

P98T Fleet-Lift Tension Bar

Specify: (1) quantity, (2) name, (3) product code,


(4) corrosion resistance, if required.

DS_P98T

The Dayton Superior P98T Fleet-Lift Tension Bar is used with various Fleet-Lift Anchors to
provide a simple, inexpensive method of distributing tension forces (lifting) deep into a
precast member.
Anchor
Tonnage

Tension
Bar
(Grade 60)

3,000 psi

4,000 psi

5,000 psi

1-ton or 2-ton

#3

32"

28"

26"

3-ton or 4-ton

#4

44"

38"

34"

6-ton or 8-ton

#6

66"

56"

50"

10-ton

#8

110"

95"

85"

22-ton

#11

155"

134"

120"

L=Overall Length of P98T Tension Bar

L = Overall length of tension bar based on concrete compressive strength at time of lift.

11/12

Fasten
tension bar
tight against
the bottom
side of hole.

30

Correct
Installation of
Tension Bar
(Installed with
equal length legs.)

61

Fleet-Lift System
P99 Fleet-Lift Reusable Recess Plug DS_P99
The Dayton Superior P99 Fleet-Lift Reusable Recess Plug is molded from an
elastomeric thermal-set urethane for multiple reuse.
Embedded in the recess plug is a stainless steel stud that securely captures a
FleetLift Anchor, providing a positive connection to the form during the placement
of concrete. Attachment to the form is accomplished with a P100 Holding Rod and
P101 Fleet-Lift Holding Plate.
Fleet-Lift System

P99 Recess Plugs are resistant to heat and form release


agents encountered in a precast plant.

Stainless
Steel Stud

Section View

To Order:
Specify: (1) quantity, (2) name, (3) product code,.

Example:
200, P99 Fleet-Lift Reusable Recess Plug, FL062.
B
D

P99 Fleet-Lift Reusable Recess Plug

Typical Reusable Recess Plug Application

Anchor
Tonnage

Product
Code

1-ton

FL051

1-11/16"

1-3/4"

4-1/16"

3/16"

1-3/16"

3/8"

2-3 ton

FL200

1-11/16"

1-3/4"

4-1/16"

3/8"

1-3/16"

3/8"

4-6 ton

FL062

2-1/8"

2-5/16"

5-3/16"

5/8"

1-11/32"

3/8"

8-10 ton

FL121

3-1/8"

3-5/16"

7-13/16"

3/4"

1-31/32"

3/8"

Note: Recess Plug style FL051 is used with the 1-ton L-Anchor and 2-ton Ring Clutch combination ONLY.

P100 Fleet-Lift Holding Plate and P101 Fleet-Lift Holding Rod DS_P100
Fixed Wing Nut
DS_P101
P100 Fleet-Lift Holding Plate
Anchor
Tonnage

Product
Code

1-ton

FL160

5/8"

2-3/4"

10mm

2-2 ton

FL160

5/8"

2-3/4"

10mm

4-6 ton

FL144

1-1/4"

3-3/8"

10mm

8-10 ton

FL111

1-3/4"

4-7/8"

12mm

6"
Standard
B

P100 Fleet-Lift Holding Plate


P101 Fleet-Lift Holding Rod
Anchor
Tonnage

Standard Thread
Recess
Product
Rod
Diameter
Plug
Code
Length and Type
Material

P101 Fleet-Lift
Holding Rod

To Order:

1, 2, 4, 6, 8 and 10-ton

Urethane

FL131

6"

3/8" Coil

Specify: (1) quantity, (2) name, (3) product code.

1, 2, 4, 6, 8 and 10-ton

Steel

FL131C

6"

1/2" Coil

Example:

Note: Holding Rod may be special ordered in longer lengths.

62

200, P100 Fleet-Lift Holding Plates, FL144.

11/12

Fleet-Lift System
Installation and Removal of Anchors and Reusable Recess Plugs

Fleet-Lift System

Installing an Anchor in the Recess Plug: A) Open the slot of the recess plug by placing a holding rod or screwdriver into
an outside hole and squeeze the recess open. (B) Place the anchor over the steel stud and close the recess plug. The
assembly is ready for installation.

Attaching the Assembly to the Form: A) Place the assembly against the form and position over the predrilled hole. (B)
Insert the 3/8" holding rod through the hole and thread into the recess plug. (C) Pull the assembly tight to the form by
firmly tightening the wing nut on the holding rod.

B
C

Attachment Using a Holding Plate: A) Position and attach the holding plate to the form. B) Slide the anchor assembly
over the holding plate studs and firmly against the form. (C) Installation is complete.
Note: The holding plate can be used to hold the recess plug/insert assembly in the closed position to facilitate working
the anchor into fresh concrete (wet setting). It is recommended that the back of the recess plug be covered with tape to
protect it from being filled with concrete. Be sure to vibrate to properly consolidate the concrete around the anchor. To
strip, simply remove the tape and/or cover/patch and pry the holding plate out of the recess plug with a blade screwdriver
or similar tool.

B
C

Removing the Recess Plug from the Concrete: A) After the back of the recess plug is exposed, insert a steel rod or
screwdriver into the half of the recess plug opposite the threaded stud and rotate it to loosen that half of the recess plug.
(B) After the first half of the recess plug has been loosened, use the holding rod in the other side in a scissor motion to
free the recess plug.
B

11/12

63

Fleet-Lift System
P99C Fleet-Lift Cast Steel Recess Plug
The Dayton Superior P99C Fleet-Lift Cast Steel Recess Plug is
designed for high reuse, high curing temperatures and cold weather
applications. The recess Plug uses a Steel Wedge (P102) through
the anchor eye to securely hold the anchor in place. A Foam Strip
(P103) fits over the head of the anchor to prevent concrete from
entering the void.

To Order:
Specify: (1) quantity, (2) name, (3) product code.

Example:
200, P99C Fleet-Lift Cast Steel Recess Plug, FL100.

Fleet-Lift System

The recess plug/anchor assembly is secured to the form work with


the 1/2" diameter Holding Rod (P101) or simply nailed to the form.
Recess plug, steel wedge and foam insert are sold separately.
DS_P99C

P102
Steel Wedge

3/8" Dia. (1/2"


dia. optional)
C

P99C Cast Steel


Recess Plug

P99C Fleet-Lift Cast Steel Recess Plug


P99C Fleet-Lift Cast Steel Recess Plug
Dimensions

Anchor
Tonnage

Product
Code

2- or 3-ton

FL078

1-7/8"

1-3/4"

4"

4- or 6-ton

FL100

2-3/8"

2-3/8"

5-3/8"

8- or 10-ton

FL015

3-3/8"

3-3/8"

7-3/8"

P102 Fleet-Lift
Steel Wedge
P102 Steel Wedge

P103
Foam

P103 Fleet-Lift
Foam
P103 Foam

Anchor
Tonnage

Product
Code

Anchor
Tonnage

Product
Code

2- or 3-ton

FL017

2- or 3-ton

FL087

4- or 6-ton

FL084

4- or 6-ton

FL069

8- or 10-ton

FL085

8- or 10-ton

FL091

Typical Fleet-Lift
Anchor

P99C Fleet-Lift Cast Steel Recess


Plug Assembly Sequence

64

11/12

Fleet-Lift System
Installation and Removal of the Fleet-Lift Cast Steel Recess Plug

Fleet-Lift System

Installing the Cast Steel Recess Plug to an Anchor: A) Place the foam strip over the top of the anchor. (B) Place the
anchor and foam into the recess slot . (C) Slide the curved steel wedge into the top of the recess plug and through the
anchors eye and wedge tightly.

B
A

Complete Assembly
Attaching the Recess Plug/Anchor Assembly to the Form: A) Place the assembly over the predrilled hole. (B) Insert
a holding rod through the hole and thread it into the recess plug. Tighten the holding rod against the anchor with the
fixed wing nut. (C) Tighten the assembly against the form with the free-running wing nut.

Fixed
Nut

Free-Running
Nut

Removing the Cast Steel Recess Plug: A) Remove the holding rod from the recess plug. (B) Remove the form. (C)
Remove the steel wedge by tapping on the small end with a hammer. (D) Thread the holding rod back into the recess plug
and tighten until it pushes the recess out of the void.

11/12

65

Fleet-Lift System
P99D Fleet-Lift Disposable Recess Plug (PVC) DS_P99D
The Dayton Superior P99D Fleet-Lift Disposable Recess Plug can be used to preset Fleet-Lift face-lift or edge-lift anchors
or can be used to wet set P94 Anchors. The Cover/Patch fits tightly onto the recess plug to fully protect the unit. The
Cover/Patch is concrete gray in color and can be used as a patch over the recess opening for temporary or permanent cover.

Recess Plug Components:

Fleet-Lift System

The Disposable Recess Plug can be ordered in sets


consisting of a body with a preinstalled clip and a lid, or
as individual pieces. This gives the system the versatility
to meet your requirements without having to order parts
that are not needed.

Body

Cover/Patch

To Order:
Specify: (1) quantity, (2) name, (3) complete
sets or individual part, (4) product code.
Standard
Anchor Clip

Example:
200, P99D Fleet-Lift Disposable Recess Plug
Cover/Patches, FL067S.

Disposable Recess Set

Cover/Patch

Standard
Anchor Clip

Body

P99D Fleet-Lift Disposable Recess Plug

Anchor
Tonnage
1,2 and
3-ton

4 and 6-ton

8 and
10-ton

66

Product
Description

Product
Code

Body
Lid

FL066B

FL066L

2-7/16"

3/8"

4-1/4"

Set

FL066S

Body

FL067B

2-7/16"

2"

4-1/4"

5/8"

Lid

FL067L

2-7/8"

5-1/2"

Set

FL067S

2-7/8"

2-1/2"

5-1/2"

Body

FL068B

3/4"

Lid

FL068L

3-7/8"

8-5/16"

Set

FL068S

3-7/8"

3-1/2"

8-5/16"

11/12

Fleet-Lift System
Installation of P99D Disposable Recess
Plug and Erection Anchors
Remove the Clip

(A) Remove the clip from the recess plug. The clip will not be
used with the erection anchor. (B) Open the body of the recess
plug enough to allow the anchor to slide into the recess plug.
(C) Close the recess plug around the anchor. Recess plug/anchor
assembly is completed.

Attaching the Erection Anchor/Recess Plug to the Form:


Four methods are displayed in the sketches:
1. Edge Installation TwoStep Method (A) Nail the cover/patch to the
edge form for position. (B) Push the anchor/recess assembly onto cover/
patchs studs until fully seated and nail the recess plug to the form.

Clip Removed
Ready for Erection
Type Anchor

2. Edge Installation OneStep Method Place the anchor/recess plug


assembly (with cover/patch attached) in the desired position and nail
the assembly to the edge form.
3. Edge Installation Double-Faced Tape Place double-faced tape on
the cover/patch and press the assembly onto the edge form in the
desired position.
4. Edge Installation With Holding Rod (A) Drill out and remove one
of the studs on the cover/patch. (B) Install the cover/patch on the
recess plug body with the drilled-out hole over the threaded insert in
the recess plug body. (C) Place the recess plug/anchor assembly over a
predrilled hole in the edge form. (D) Firmly attach the assembly to the
edge form with a 3/8" holding rod.

Erection Anchor Installed


Ready for Cover/Patch

1) Edge Installation TwoStep


1A)

1B)

2) Edge Installation OneStep

3) Edge Installation Double-Faced Tape

Remove stud
with drill

Double-Faced Tape

4) Edge Installation With Holding Rod


Holding Rod

Reusable Recess Plug

11/12

67

Fleet-Lift System

Installing an Erection Anchor in a Disposable


Recess Plug:

Fleet-Lift System
Installation of P99D Disposable Recess Plug
and Standard Anchors
Installing Standard Anchors in the Disposable Recess Plug:

Fleet-Lift System

To install standard, non-erection head anchors, open the Dayton Superior


P99D Disposable Recess Plug just enough to allow the anchor to be inserted
fully into the body of the recess plug. Do not excessively open the body
to avoid damaging the recess plug. Note that the anchor clip fits snugly
against the anchor to seal out any concrete leakage. Snapping the cover/
patch onto the recess plug completes the installation.

Installing an Anchor

Setting Standard Anchors with the Disposable Recess Plug:


The recess plug/anchor assembly can be set in position in a variety of
methods: (1) by nailing it to a support beam and suspending it above
the surface of the concrete, (2) nailed or double-faced taped to the form
face or (3) wet set. Wet setting is accomplished by nailing or taping the
assembly to a small template board and then working the assembly down
into the freshly poured concrete. Light vibration is usually needed to ensure
good bond around the anchor. A properly placed anchor will have the
cover/patch slightly below the surface of the concrete. This will facilitate
screeding operations and will aid in locating the recess after curing.
Install Cover/Patch
Block

Support

Top of Concrete
Edge
Form

WetSet

Nail or
Double-face Tape

Disposable Recess Plug Removal:


(A) To remove the cover/patch Place a blade screwdriver in the center of
cover/patchs side and carefully dislodge and remove the cover/patch. (B)
S-Anchor Installed
To remove the recess plugs body Insert a screwdriver or similar tool into
each round hole in the recess plug and rotate the tool to remove the body.
Remove recess body by inserting screwdriver
The anchor clip may remain in the recess and require a separate removal.
into each round hole and rotate to release.
Remove body.
Note: Body clip may remain in recess and
require separate removal.

68

11/12

Fleet-Lift System
P99D Temporary Cover/Patch Installation

When planning to use the cover/patch as a temporary cover, be careful when


removing the cover to avoid damage. Simply replace the cover/patch into the
formed recess, flush with the surface of the concrete. A silicone adhesive may be
used on the inner rim of the recess to prevent water from entering the recess.

Support Rim:
use silicone
adhesive on
this area for
permanent or
water tight patch

Permanent Cover/Patch Installation


When used as a permanent patch, the cover/patch eliminates the need to grout
and will protect the anchor from the environment. The light gray color of the
unit will blend with most normal concrete, or it can be painted to closely match
other color applications.
When anticipating the use of the cover/patch as a permanent application, be careful
during removal to protect the integrity of the concrete around the perimeter of the
recess. An application of a silicone or other type adhesive to the inner rim of the
recess will seal out the elements or other contaminants. If the recess plug/anchor
assembly was installed flush with the concrete surface, the cover/patch will be flush
in its permanent position. Future access to the anchor is easily accomplished by
removing the cover as described earlier.
Additional cover/patches may be purchased separately, if required.

Reinstalled as a temporary or
permanent patch

Protective Cap for Reusable Recess Plugs


The cover/patch can be used as a protective cap for the reusable recess plug.
This will protect the recess plug and will eliminate the use of duct tape to
cover the back of the recess plug. After installing the anchor in the recess
plug, snap the cover/patch onto the recess plug. The cover/patch can be
ordered separately for this purpose and can be used and reused many times
in this type of installation.

T-Anchor
Reusable Plastic
Recess Plug

Disposable
Cover/
Patch

11/12

69

Fleet-Lift System

The Dayton Superior P99-D Cover/Patch can be used as a temporary cover to keep
sand, rain, snow, debris, etc., out of the recess. Under normal precast plant yard
conditions, it will stay in place without adhesive.

Fleet-Lift System
P99P Fleet Patch DS_P99P
The Dayton Superior P99P Fleet Patch is a durable plastic patch designed to
quickly cover 2-ton and 4-ton Fleet-Lift setting plug recesses. The P99P patch
is fabricated from an additive stabilized polypropylene to maintain the patchs
slightly convex shape. The convex shape helps to keep a constant gripping
pressure after installation. The patch is supplied in a concrete gray color with a
matte finish that allows subsequent painting, if desired.

Fleet Patch Advantages:


Fleet-Lift System

Special shape-holding composition.

Fast, one-piece push-on installation.

Paintable concrete gray matte finish.

Full eight (8) inch diameter.

Weather and chemical resistant.

Self adjusting grippers.

The P99P Fleet Patch is a high quality, one piece plastic patch that is easy
to install and maintain. It will provide a quick and economical solution to
covering Fleet-Lift anchor recesses.
P99P Fleet Patch

Typical P99P Fleet Patch Installation:


1) Start the patch grippers on the top edge of the anchor.

Fleet Patch

2) Push the patch onto the anchor and flush with the concrete.
Note: The P99P Fleet Patch will not prevent corrosion or rusting of an embedded anchor that is subject to wet conditions. Spraying the anchor with a corrosion resistant compound and applying a bead of silicone around the underside
of the patch will help prevent moisture penetration.

Sales
Category

Product
Code

Weight for
100

P99P

FL612

24 lbs.

To Order:
Specify: (1) quantity, (2) name, (3) product code.

Example:
200, P99P Fleet Patch, FL612.

70

11/12

Fleet-Lift System
P100M Fleet-Lift Magnetic Plate

Setting Stud

The Dayton Superior P100M Fleet-Lift Magnetic Plate eliminates the need for
drilling setting-bolt holes in steel forms. Installed into a rubber base is a set of
strong, reliable magnets. These magnets, along with an attachment stud and
setting screw, work together to hold a Fleet-Lift anchor tightly in position during
the placement of concrete.

DS_P100M

P100M Fleet-Lift
Magnetic Plate

P100MS Setting Screw DS_P100MS


Provided with 3/8" coil threads and used to attach the magnetic setting plate to the P99 Recess Plug, this
unit has either a slot or hex in the head.
Use the 1-1/2" long setting screw with the 1, 2 and 3-ton system and the 2-3/8" long setting screw with
both the 4 to 6-ton and the 8 to 10-ton systems.

P100MS Setting
Screw

P100M Fleet-Lift Magnetic Plate Installation

1. Attach Fleet-Lift Anchor to recess


plug.

2. Push recess plug onto setting stud of


the magnet using the non-threaded
middle hole.

3. Place the P110MS Setting Screw


through the hole in setting plate,
securing setting plate tightly to
recess plug.

4. Carefully set complete anchor assembly


into proper position in the form.

P104 Fleet Lift One Piece Magnetic Recess


The Dayton Superior P104 One Piece Magnetic Recess allows installation of the
Fleet anchors in a metal face form using a one piece rubber recess with magnets
imbedded in the top of the recess. Available in 2T, 4T and 8T products.
DS_P104

11/12

71

Fleet-Lift System

The P100M Magnetic Plate is available in three sizes to fit the three P99 Fleet-Lift
Recess Plugs.

Notes and Sketches

72

11/12

Utility Anchor
Utility Anchor System
The Dayton Superior Utility Anchor System is designed to economically simplify
the lifting and handling of precast concrete elements. Its economics, ease of
use and versatility will be a welcome addition to your precast operations.

Key Advantages

High strength up to 24,000lbs. SWL

No special lifting hardware required

Uses a standard hook or clevis

Easy to install and use

Utilizes reusable 90 and 45 polyurethane recess plugs

Eliminates through holes in the precast element

An economical and versatile system applicable to any precast concrete element

Added Benefit
Utility Anchor
Lifting System

Utility contractors can use the utility anchor effectively as a pulling iron. When
used as a pulling iron, the safe working loads may be increased by 33%, based
on the use of a 3 to 1 factor of safety.
The design of the Dayton Superior Utility Anchor Utility System assures the
precaster of an economical, user-friendly system for lifting and handling
precast concrete elements.

Utilize the Utility Anchor System to:


Remove precast elements from their forms

Handle in the precast yard

Load for shipment

Unload and place at the job site

The precaster is able to do it all without the need for any special lifting equipment or hardware. Simply use a standard
hook or shackle to connect slings to the utility anchor for a safe lift.
The Utility Anchor System uses a polyurethane recess plug to create a void in the concrete. The concrete void created for
the P75H utility anchor is sufficiently large to accept the following:
1. 6-ton Grade 8 alloy hook or
2. 7-ton forged alloy shackle
For the P75S Utility Anchors:
3. 15-ton cast/alloy hook or
4. 15-ton forged alloy shackle
DO NOT use larger hooks or shackles; they will apply additional and unintended loads to the utility anchor and could cause
a premature failure of the concrete or anchor.

Anchor Placement
Placement of the Utility Anchor is dependent on the structural shape of the
precast element. Utility anchors are not designed for thin edge installation.
Always maintain minimum edge distances. For special conditions, contact the
nearest Dayton Superior Technical Service Department for assistance.

Lift
Lift
Lift

Pulling
Iron

Typical
Applications
Minimum
Edge
Distance

Used To Load/Install

11/12

73

Utility Anchor
P75 and P75H Utility Anchor DS_P75_P75H
The Dayton Superior Utility Anchors are available in three diameters and a series of lengths
for specific concrete thickness. The utility anchor can be set in either a 90 or a 45 anchor
orientation using the appropriate setting plug.

P75 and P75H Utility Anchor


Anchor

P75

P75H

Type

Product
Code No.

End
Shape

4UA444

121877

5-1/4"

3-1/8"

0.444"

Swift Lift

5UA444

123442

6"

3-3/4"

0.444"

Swift Lift

6UA444

121888

7-3/8"

4-3/4"

0.444"

Swift Lift

5UA671

123441

6-7/16"

3-3/4"

0.671"

Swift Lift

6UA671

121889

7-3/8"

4-3/4"

0.671"

Swift Lift

8UA671

121891

9-3/4"

6-3/4"

0.671"

Swift Lift

12UA875

124738

15-7/8"

11"

0.875"

Swift Lift

Utility Anchor
Lifting System

P75H

Type

Product
Code
No.

Minimum
Panel
Thickness

Safe Working
Load Tension
90

Safe
Working
Load Shear
90

Safe Working
Load Tension/
Shear 45

Minimum
Edge
Distance

4UA444

121877

4"

3,200

5,800

2,260

9"

5US444

123442

5"

3,860

7,710

2,730

10"

6UA444

121888

5-5/8"

4,460

9,460

3,150

12"

Anchor

P75

P75 Utility Anchor

5UA671

123441

5"

4,560

8,430

3,220

10"

6UA671

121889

5-5/8"

7,320

15,780

5,170

12"

8UA671

121891

7-5/8"

10,830

18,850

7,660

16"

12UA875

124738

12"

24,000

24,000

24,000

30"

Note:
1. Compressive strength of normal weight concrete to be 4,000 psi at time of initial lift.
2. Safe working loads provide an approximate factor of safety of 4 to 1.
3. Utility anchors to be installed at 90 to surface of the concrete.
4. Shear safe working loads are based on loading in the direction of the top of the precast concrete element.

P75H Utility Anchor

To Order:
Specify: (1) quantity, (2) name, (3)
product code.

Example:
200, P75 Utility Anchors, 5UA444.

P75C Utility Anchor with Clip DS_P75C


The Dayton Superior Utility Anchor with Clip is designed to allow the Utility Anchor to be secured to the wire mesh cage.
This product utilizes the P75 Utility Anchors with 2 wire clips welded to opposite legs of the anchor. These wire clips are
positioned to hold the utility anchor with Void to the wire mesh in the proper position in the wall for lifting your precast
product. Both the 5UA and 6UA anchors in 0.444 and 0.671 diameters for 9" wire spacing are in stock. Other anchor and
wire spacing are readily available.

To Order:
Specify: (1) quantity, (2) name, (3) product code
(4) anchor size, (5) wire spacing (6) wall thickness.

Example:
200, P75C, #121443, 5UA444anchor, 9" wire
spacing, 5" wall.
Product Code

Utility
Anchor

Wire Clip
Lengths

Wall
Thickness

123443

5UA444

9"

5"

74

121890

5UA671

9"

5"

121892

6UA444

9"

6"

121893

6UA671

9"

6"

127446

8UA671

9"

8"

11/12

Utility Anchor
P76 Utility Anchor Setting Plugs

DS_P76

Utility Anchor Setting Plugs a polyurethane


plastic in 90 and 45 orientation.

The 90P875 Setting Plug used with the P75-H


24,000 lb. anchor requires 2 each P101 holding
rods to attach setting plug to the form. No
holding plate or magnetic plate are available
for this setting plug.

P76 Utility Anchor Setting Plug


Type

Product
Code No.

Length

Width

Depth

Color

90P444

123175

8.00"

3.25"

3"

Blue

45P444

123176

8.00"

3.25"

3"

Blue

90P671

123177

8.00"

3.25"

3"

Orange

90P671

127786

9.00"

4.58"

3.35"

Orange

45P671

123178

8.00"

3.25"

3"

Orange

90P875

124685

15.00"

6.13"

5"

Blue

To Order:
Specify: (1) quantity, (2) name, (3) product code.

Example:
200, P76 Utility Anchor Setting Plugs, 90P444.

90

45

P76 Utility Anchor Setting Plugs

P76D Disposable Setting Plugs

DS_P76D

The Disposable Setting Plug is manufactured to offer the precaster an inexpensive


alternate to urethane setting plugs. This 2 piece high density polyethylene plastic
setting plug is used with the 0.671 Dayton Superior Utility Anchors. The two piece
design snaps tightly together around the legs of the anchor eliminating concrete
entering the void. The setting plug is installed to the formwork using nail holes
on each end of the plug. This plug can also be used with the P77 Double Tee
Anchors.

To Order:
Specify: (1) quantity, (2) name, (3) product code.

Example:
200, P76D, #126214.

P76D Disposable Utility Anchor


Setting Plugs 0.671

P76C Utility Anchor Cover/Patch


The P76C Utility Anchor Cover/Patch installs over the back of the setting plug
to protect the unit without the use of duct tape. The cover/patch can be
installed on the setting plug/anchor assembly prior to setting the assembly
in the form. This protects the assembly from concrete leakage through the
concrete placement sequence. It can also be used later as a temporary or
permanent cover for the recess. The P76C cover is gray in color and will blend
with most concrete. It can be painted to match other color schemes.
DS_P76C
P76C Utility Anchor Cover/Patch

11/12

75

Utility Anchor
Lifting System

The reusable setting plug properly sets the


anchor approximately 1/2" below the surface
of the concrete and provides an adequate
recess for easy sling attachment. After final
positioning of the concrete element, the recess
formed by the recess member can be easily
grouted or conveniently covered by the Utility
Anchor Cover/Patch.

Utility Anchor
P76M Utility Anchor Magnetic Setting Plate DS_P76M
The Dayton Superior P76M Utility Anchor Magnetic Setting Plates are available
for easy setting of utility anchors in steel precast forms.
Use 3/8" P101 Holding Rod in threaded through hole to strip magnet from steel form.

To Order:
Specify: (1) quantity, (2) name.
Threaded Through-Hole used
to release magnet from form.

Example:
200, P76M Utility Anchor Magentic Setting Plates.

P76M Utility Anchor


Magnetic Setting Plate

P100 Utility Anchor Holding Plate DS_P100


P101 Utility Anchor Holding Rod DS_P101
Utility Anchor
Lifting System

The Dayton Superior P100 Utility Anchor Holding Plate and P101 Holding Rod are used
in various applications to install Utility Anchors in the form. The Holding Plate can be
nailed, screwed, welded or double-face taped to the form. The setting plug/anchor
assembly is pushed onto the projecting studs of the plate and held firmly in place through
the concrete placement.
The Holding Rod is placed through a predrilled hole in the form and into the threaded insert in
the setting plug. After fully seating the holding rod in the setting plug, the setting plug can be
pulled up tightly to the form with the holding rods free-running wing nut.

P100 Utility Anchor


Holding Plate
(FL111)

6" (Typ.)

To Order:
Specify: (1) quantity, (2) name, (3) anchor diameter.

Example:
200, P100 Utility Anchor Holding Plates, 0.671
anchor diameter.

P101 Utility Anchor Holding Rod


(3/8" Coil Thread) (FL131)

P104 One Piece Magnetic Utility Anchor Recess DS_P104


The Dayton Superior P104 One Piece Magnetic Utility Anchor Recess allows
installation of Utility Anchors in a metal face form using a one piece rubber recess
with Magnet imbedded in the top of the recess. Available for 0.444 or 0.671 Utility
Anchors.

To Order:
Specify: (1) quantity, (2) name.

Example:
200, P104 One Piece Magnetic Utility Anchor Recess.

76

11/12

Utility Anchor
Anchor Placement
Placement of the Utility Anchor is dependent on the structural shape of the precast unit and/or the manufacturers
preference. The Utility Anchors are not designed for thin edge installations. Always maintain minimum edge distances and
adjust anchor capacities if concrete strengths, other than those noted in the capacity chart, are encountered. Refer to edge
distance chart on next page.

In-Form setting:
1. Assemble setting plug and anchor.
2. Affix holding plate (nail, weld, magnetic setting plate, double-face tape) to the form.
3. Push the setting plug/anchor assembly onto the holding plate and firmly against the form.

Through-Form Setting
1. Assemble setting plug and anchor.
2. Insert holding rod through form and line up setting plug.

Wet Setting
1. Assemble setting plug holding plate and anchor.
2. Use cover/patch or duct tape to seal setting plug cavities.
3. Work the assembly down into the wet concrete until the top surface of the plug is flush with the surface of the concrete.
Place
long
stud at
top

Form

Utility Anchor
Setting Plug

Utility Anchor
Setting Plug
Utility Anchor
Holding Rod

Utility
Anchor

Utility
Anchor

Utility
Anchor Holding Plate
(8-Ton Fleet-Lift Unit)
Form

In-Form Setting

Through-Form Setting

Setting Plug
Cover/Patches
are available

Cover/Patch may be
added to this installation
if future sealing of recess
is required. Drill out one
stud of Cover/Patch to pass
holding rod through.

Holding Plate

Wet Setting

11/12

77

Utility Anchor
Lifting System

3. Finger-tighten holding rod and lock assembly in place with the running wing nut.

Utility Anchor
P77 Double Tee Anchor DS_P77
The Dayton Superior P77 Double Tee Anchor is specifically designed to provide greater lifting capabilitites for Double Tees
and other concrete products. This Anchor has the capacity of 13,500 lbs. The anchors are designed to utilize the standard
field Crosby Hooks for lifting of the Precast Product, requiring no special hardware be purchased by the precaster or
erector. The head of the anchor is 1/2" below the concrete surface to prevent rusting and to eliminate any removal of steel,
a common practice when using "strand" as an anchor. The recess member (P75D) utilized to form the void is designed to
allow up to a 30% angle on the sling to prevent spalling of the concrete from the contact with the Crosby Hook. A smaller
void is also available if sling angle and hook size are reduced. See P76D Disposable Void Former.
P77 Double Tee Anchors are available in 3 common lengths of 9-1/2, 15-1/2" and
23-1/2" All are stocked in plain finish and available in Hot-dipped galvanized finish.
Product
Code

Safe Working
Load *

126728
126726
126727

9-1/2"
15-1/2"
23-1/2"

5/8"
5/8"
5/8"

3-3/4"
4"
4"

13,500 #
13,500 #
13,500 #

* Mechanical Safe Working Load provides a factor of safety of 4:1

Utility Anchor
Lifting System

To Order:
Specify: (1) quantity, (2) name, (3) product code, (4) finish.

Example:
200, P77 Double Tee Anchor #126728, plain.
C

P76D Disposable Void Former DS_P76D


The Dayton Superior P76D Disposable Void Former was created to allow a large
enough void for the P77 Double T Anchor to utilize Crosby Hooks for lifting
of the double T and other precast products. The Disposable Void Former is a
twopiece recess plug fabricated from high density polyethylene plastic. The
two-piece design snaps together around the head of the anchor to securely grasp
the anchor. The tight fit eliminates concrete entering into the void. The design
secures the anchor in proper position and maintains 1/2" clearance
between top edge of the anchor and the top surface of the concrete. To Order:
The tabs on the ends of the void former provide a convenient method Specify: (1) quantity, (2) name, (3) product code,
to nail the assemble to a form. The Void Former is removed and
(4) finish.
discarded after usage.

Example:

200, P76D Disposable Void Forms #126608.

P76 Utility Anchor and Double Tee Anchor Setting Plug DS_P76
The new P76 Setting Plug is a re-usable polyurethane setting plug designed to
provide a larger recess in the concrete for the 0.671 Utility Anchors and the
Double Tee Anchors. This setting plug is 9.0" in length, 4.5" in width across the
top, and 3.3" in depth. This recess member positions the anchor at a 90 degree
angle to the surface of the concrete product. The reusable setting plug sets the
anchor approximately 1/2" below the top of the concrete. The setting plug is
attached to the form with the P101 Holding Rod and/or the P100 Holding Plate.
The P76 Setting Plug is stripped from the concrete by placing two
3/8" dia. rods into the holes provided in the plug and using a 'scissor
To Order:
action' to strip the plug from the anchor.
Specify: (1) quantity, (2) name, (3)product code.

Example:
200, P76 Utility Anchor and Double Tee Anchor
Setting Plug, #127786.

78

11/12

Utility Anchor
P110 Wire Rope Lifting System DS_P110
The Wire Rope Lifting System is an economical lifting loop for utility type structures. It is used in face lift
applications and is mucked into the surface of the concrete. The galvanized wire rope is formed in a figure
8 shape, with the ends of the rope secured by a positive swaged clamp, and a steel band at approximately
the mid point to establish the proper shape. The Wire Rope Lifting System is embedded 2/3 of its length
into the concrete. The hardware must be standard hook or clevis with a diameter at least twice the rope
diameter. Each anchor has a color-coded tag which identifies the SWL in tension of the anchor.

Product Features and Benefits:







7 standard sizes handles most precast applications up to 10,000 lb SWL


Mucked into surface no recess members required by the precaster
Uses standard jobsite Crosby Hooks no hardware purchases required by precaster.
Galvanized wire rope reduces rusting of the anchor
Can be cut off or left exposed reduces labor cost for precaster
Economical for the cost conscious precaster
Utility Anchor
Lifting System

To Order:
Specify: (1) quantity, (2) name, (3)product code.

Example:
200, P110 Wire Rope Lifting System #127327.
Part #

Description

#127326
#127327
#127328
#127329
#127330
#127331
#127332

0.8 T
1.2 T
1.6 T
2.0 T
2.5 T
3.8 T
5.0 T

Safe Working
Load
1,600#
2,400#
3,200#
4,000#
5,000#
7,600#
10,000#

8.07"
9.06"
9.84"
11.81"
12.80"
14.57"
14.96"

3.7"
3.9"
5.1"
5.3"
5.5"
6.5"
7.6"

3.3"
3.5"
4.9"
4.9"
4.9"
5.7"
5.7"

5.7
6.6
7.1
8.7
9.4
10.7
11.1

2
2.50
2.75
3.13
3.38
3.88
3.80

0.24
0.275
0.313
0.354
0.394--0.473
0.630

NOTE: SWL is 4:1 SF in 3000 psi concrete

Tag Color: White= 0.8T, Red= 1.2T, Pink= 1.6T, Light Green= 2.0T,
Dark Gray= 2.5T, Emerald Green= 3.8T, Light Yellow= 5.0T
Wire Loop Parellel To Wall Thickness
Anchor
Tonnage
0.8 ton
1.2 ton
1.6 ton
2.0 ton
2.5 ton
3.8 ton
5.0 ton

Minimum
Wall
Thickness
4.0"
4.5"
4.75"
6"
7.0"
9.0"
12"

Overall
Length

Emdedment
Depth

8.0625"
9.375"
9.8125"
11.8125"
12.34"
14.5"
14.9375"

5.7"
6.5"
7"
8.7"
9.4"
10.7"
11.1"

Minimum
Edge
Distance
2.0"
2.25"
2.375"
3"
3.5"
4.5"
6"

Minimum
Corner
Distance
8.75"
9.75"
10.5"
13.25"
14.25"
16.25"
16.75"

SWL @ Concrete Strength Maximum


3000 psi For maximum SWL
SWL
1,600lbs
2,400lbs
2,841lbs
3,547lbs
4,898lbs
6,796lbs
9,539lbs

3,000 psi
3,000 psi
4,000 psi
4,000 psi
3,500 psi
4,000 psi
3,500 psi

1,600lbs.
2,400lbs
3,200lbs
4,000lbs
5,000lbs
7,600lbs
10,000lbs

Wire Loop Perpendicular To Wall Thickness


Anchor
Tonnage
0.8 ton
1.2 ton
1.6 ton
2.0 ton
2.5 ton
3.8 ton
5.0 ton

11/12

Minimum
Wall
Thickness
5.5"
6"
6.5"
7"
7.5"
9.0"
12"

Overall
Length

Emdedment
Depth

8.0625"
9.375"
9.8125"
11.8125"
12.34"
14.5"
14.9375"

5.7"
6.5"
7"
8.7"
9.4"
10.7"
11.1"

Minimum
Edge
Distance
2.75"
3"
3.25"
3.5"
3.75"
4.5"
6"

Minimum
Corner
Distance
8.75"
9.75"
10.5"
13.25"
14.25"
16.25"
16.75"

SWL @ Concrete Strength Maximum


3000 psi For maximum SWL
SWL
1,600lbs
2,400lbs
2,700lbs
3,474lbs
4,251lbs
5,468lbs
7,739lbs

3,000 psi
3,000 psi
4,500 psi
4,000 psi
4,500 psi
6,000 psi
5,000 psi

1,600lbs.
2,400lbs
3,200lbs
4,000lbs
5,000lbs
7,600lbs
10,000lbs

79

Notes and Sketches

80

11/12

Lifting and Handling Inserts


B1 or B2 Coil Ties Used as Inserts DS_B1B2

Minimum
Corner
Distance
or Greater

The Dayton Superior B1 Two Strut Coil Tie and B2 Four Strut
Coil Tie, when used as inserts for lifting and handling thin wall
precast elements, are extremely effective.

Minimum
Corner
Distance
or Greater
Minimum Edge
Distance or Greater

Coil ties are available with an optional B3 Screw-on Coil for use
with the B30 Screw-on Plastic Cone to set the insert back from
the face of the concrete.

Minimum Edge
Distance or Greater

Minimum spacing between inserts is twice the corner distance.

Shear
Direction

Bolt
Diameter
3/4"
3/4"
1"
1"
1 1/4"
1 1/4"
3/4"
3/4"
1"
1"
1"
1"
1 1/4"
1 1/4"
1 1/4"
1 1/4"

Insert
Height
6"
6"
6"
6"
8"
8"
6"
6"
8"
8"
12"
12"
8"
8"
12"
12"

Minimum
Edge Distance
8"
14"
8"
16"
10"
16"
8"
12"
10"
16"
10"
15"
12"
15"
15"
20"

Minimum
Corner Distance
14"
21"
14"
24"
15"
24"
14"
16"
15"
24"
15"
22"
18"
22"
22"
30"

Safe Working
Load Tension
4,500lbs
4,500lbs
5,447lbs
6,120lbs
6,750lbs
6,750lbs
5,536lbs
6,220lbs
7,897lbs
9,000lbs
9,000lbs
9,000lbs
9,400lbs
9,400lbs
13,500lbs
13,500lbs

Safe Working
Load Shear
2,810lbs
4,500lbs
3,200lbs
6,120lbs
4,670lbs
6,750lbs
4,710lbs
6,220lbs
5,640lbs
9,000lbs
6,100lbs
9,000lbs
7,840lbs
9,390lbs
10,500lbs
13,500lbs

6"
6"
6"
6"
8"
8"
6"
6"
8"
8"
12"
12"
8"
8"
12"
12"

1 5/8"
1 5/8"
2 1/4"
2 1/4"
2 1/2"
2 1/2"
1 5/8"
1 5/8"
2"
2"
2"
2"
2 1/2"
2 1/2"
2 1/2"
2 1/2"

0.375"
0.375"
0.440"
0.440"
0.440"
0.440"
0.375"
0.375"
0.375"
0.375
0.375"
0.375"
0.440"
0.440"
0.440"
0.440"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
NOTE: Contact Dayton Superior Technical Assitance for shear loads for inserts located near
an edge smaller than in the table.B1 or B2 Coil Ties
B

Insert
Type
B1
B1
B1
B2
B2
B2
B2
B2

Bolt
Diameter
3/4"
1"
1 1/4"
3/4"
1"
1"
1 1/4"
1 1/4"

Insert
Height
6"
6"
8"
6"
8"
12"
8"
12"

Safe Working Safe Working


Load
Load Tension
Mechanical
Concrete *
4,500lbs
6,220lbs
6,750lbs
6,120lbs
6,750lbs
9,400lbs
9,000lbs
6,220lbs
9,000lbs
9,514lbs
9,000lbs
17,525lbs
13,500lbs
9,400lbs
13,500lbs
17,369lbs

6"
6"
8"
6"
8"
12"
8"
12"

1 5/8"
2 1/4"
2 1/2"
1 5/8"
2"
2"
2 1/2"
2 1/2"

0.375"
0.440"
0.440"
0.375"
0.375"
0.375"
0.440"
0.440"

NOTE: * SWL Tension Concrete values are provided for use with the tables on pages 17
and 18 for tension load reduction due to edge distance conditions closer than 1.5 x the
insert length. Installed SWL is determined by the actual concrete capacity (edge conditions,
strength, etc.), but can never be greater than the mechanical rating of the anchor.

A
C

B1 Two Strut Coil Tie


A
C
B

B2 Four Strut Coil Tie

To Order:
Specify: (1) quantity, (2) product code, (3)
bolt diameter, (4) length, (5) finish.

Example:
400, B1 Coil Ties, 1-1/4" dia. x 8" long,
plain finish.

Mounting Washers
Most Dayton Superior 1/2", 3/4", 1", 1-1/4" or 1-1/2" diameter coil inserts are available with
an 11 gauge mounting washer welded to the upper ends of the strut wires. The 1/2", 3/4"
and 1" diameter coil inserts use a 2" x 2" square washer, while the 1-1/4" and 1-1/2" inserts
use a 3" x 3" square washer.
The mounting washer allows an insert to be fastened to wood forms with ease. When
inserts are ordered with mounting washers, they are supplied with Ethafoam plugs to
keep concrete out of the coil. Removal of the Ethafoam plug clears the insert, allowing for
proper engagement of the lifting bolt.

11/12

Lifting/Handling
Inserts
and Accessories

B1 or B2 Coil Ties
Insert
Type
B1
B1
B1
B1
B1
B1
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2

3/16"
diameter
nail holes,
2 places

Mounting Washer

81

Lifting and Handling Inserts

B11 Flat Washer


Made from carbon steel.
Type
B11 Standard
B11 Heavy
B11 Standard
B11 Heavy
B11 Standard
B11 Heavy
B11 Standard
B11 Heavy
B11 Standard
B11 Heavy

Bolt
Diameter
1/2"
1/2"
3/4"
3/4"
1"
1"
1-1/4"
1-1/4"
1-1/2"
1-1/2"

Safe Working
Load
1,800lbs.
2,700lbs.
2,700lbs.
3,600lbs.
7,200lbs.
15,000lbs.
10,800lbs.
15,000lbs.
15,000lbs.
15,000lbs.

Sizes
3" x 4" x 1/4"
4" x 5" x 1/4"
4" x 5" x 3/8"
5" x 5" x 3/8"
5" x 5" 1/2"
7" x 7" x 3/4"
5" x 5" x 5/8"
7" x 7" x 3/4"
5" x 5" x 3/4"
7" x 7" x 3/4"

B11 Flat Washer

To Order:
Specify: (1) quantity, (2) type, (3) diameter of bolt
to be used, (4) finish.

Example:
200, B11 Heavy Flat Washers, 1" bolt dia., plain finish.

Safe Working Load provides a factor of safety of approximately 5 to 1.

B12 and P49 Coil Rod DS_B12P49

Lifting/Handling
Inserts
and Accessories

Available in low tensile (P49) or high tensile (B12) strengths.

May be cut with carborundum blades without damaging the threads.

Do not use cutting torch to cut coil rod to length.

Used with B13 or B25 Coil Nuts for making special coil bolts.

B12 requires two B13 or one B25 Coil Nut to develop safe working loads.

Specify: (1) quantity, (2) name, (3)


diameter, (4) length.

B12 standard length is 12'-0" and P49 standard length is 10'-0".

Example:

Available in any length up to 20'-0" on special order.

200, B12 Coil Rod, 1" dia. x 12'-0" long.

Coil Rod

To Order:

B13 Coil Nut and B25 Heavy Coil Nut


B12 Safe Working Load

Diameter

P49 Safe Working Load

Tension

Shear

Tension

Shear

1/2"

3,600 lbs.

2,400 lbs.

2,700 lbs.

1,800 lbs.

3/4"

7,200 lbs.

4,800 lbs.

1"

15,000 lbs.

10,000 lbs.

1-1/4"

22,500 lbs.

15,000 lbs.

1-1/2"

27,000 lbs.

18,000 lbs.

Safe Working Load provides a factor of safety of approximately 5 to 1.

Safe Working Load Tension

Type

Diameter

Approx.
Height

Using One B13 Nut

Using Two B13 Nuts


or One B-25 Heavy Nut

B13

1/2"

7/16"

2,400 lbs.

3,600 lbs.

B25

1/2"

1-3/16"

3,600 lbs.

B13

3/4"

5/8"

3,600 lbs.

7,200 lbs.

B25

3/4"

1-3/16"

7,200 lbs.

B13

1"

1"

9,600 lbs.

15,000 lbs.

B25

1"

2"

15,000 lbs.

To Order:

B13

1-1/4"

1-1/4"

14,400 lbs.

22,500 lbs.

Specify: (1) quantity, (2) name, (3) diameter.

B13

1-1/2"

1-1/2"

19,000 lbs.

27,000 lbs.

Example:

Safe Working Load provides a factor of safety of approximately 5 to 1.

82

Height

B13 Coil Nut

Height

B25 Heavy
Coil Nut

200, B13 Coil Nuts, 1" diameter.

11/12

Lifting and Handling Inserts


B14 Coil Bolt DS_B14
B14 coil bolts are available in 1/2", 3/4", 1", 1-1/4" and 1-1/2"
diameters with integrally formed heads.

Insert Setback
Min. Coil
Penetration

Hardware
Height
Coil

Hex Head

Coil Bolts have fast-acting and self-cleaning threads.


They can be reused, but will wear and must be regularly
inspected for wear and damage. Keep bolts clean and
lubricated at all times.

Minimum Thread
Length
Bolt
Length

When determining the overall length of a coil bolt, you


must consider:

Sufficient void beyond


coil created by setting
bolt, setting stud or
insert locator plug to
keep lifting bolt from
bottoming out.

Height of hardware and/or formwork grip.

Insert Setback.

To Order:

Minimum coil penetration

 he minimum coil penetration shown in the charts below,


T
apply to all coil products.

Specify: (1) quantity, (2) type, (3) diameter, (4) length,


(5) type.

Example:
200, B14 Coil Bolts, 1" dia. X 12" long, forged head.

1/2" Diameter

3/4" Diameter

1" Diameter

1-1/4" Diameter

1-1/2" Diameter

Forged Hex Head

Forged Hex Head

Forged Hex Head

Forged Hex Head

Forged Hex Head

Safe Working Load

Safe Working Load

Safe Working Load

Safe Working Load

Safe Working Load

Tension

Tension

Tension

Tension

Tension

Shear

Shear

Shear

Shear

Lifting/Handling
Inserts
and Accessories

B14 Coil Bolts with Integrally Formed Hex Heads


(Fabricated from Blanks Meeting ASTM A-325 Standards)

Shear

3,600 lbs. 2,400 lbs. 8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.
Minimum Coil
Penetration 2"

Minimum Coil
Penetration 2-1/4"

Minimum Coil
Penetration 2-1/2"

Minimum Coil
Penetration 2-1/2"

Minimum Coil
Penetration 3"

Bolt
Length

Minimum
Thread
Length

Bolt
Length

Minimum
Thread
Length

Bolt
Length

Minimum
Thread
Length

Bolt
Length

Minimum
Thread
Length

Bolt
Length

Minimum
Thread
Length

3"

2-1/4"

3"

2-3/4"

3"

2-3/4"

3"

2-3/4"

4"

3-1/4"

4"

3-3/4"

4"

3-3/4"

4"

3-3/4"

4"

3-3/4"

5"

4-1/4"

5"

4-3/4"

5"

4-3/4"

5"

4-3/4"

5"

4-3/4"

6"

5"

6"

5-3/4"

6"

5-3/4"

6"

5-3/4"

6"

5-3/4"

Over 6"

5"

Over 6"

5-3/4"

Over 6"

5-3/4"

Over 6"

5-3/4"

Over 6"

5-3/4"

Safe Working Load provides a factor of safety of approximately 5 to 1.

11/12

83

Lifting and Handling Inserts


B16 Straight Coil Loop Insert DS_B16

Although simple in design and fabrication, the B16 Straight Coil Loop Insert is highly
efficient for lifting and handling precast concrete elements. Standard inserts are
shown in the chart. Special inserts for use with larger diameter coil bolts, or with
loops having longer lengths and of heavier wire can be furnished, if required, on
special order.
B16 Straight Coil Loop Insert Selection Chart
Insert
Bolt
Diameter Length

1/2"

3/4"

1/2"
3/4"
or 1"

3"

4"

6"

Minimum
Edge
Distance
2"
3"
5"
10"
2"
3"
5"
8"
2"
3"
5"
12"

Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
5"
810 lbs.
200 lbs.
5"
1,310 lbs.
325 lbs.
10"
1,950 lbs.
1,050 lbs.
10"
1,950 lbs.
1,350 lbs.
5"
1,190 lbs.
200 lbs.
5"
1,910 lbs.
325 lbs.
10"
1,950 lbs.
1,050 lbs.
10"
1,950 lbs.
2,250 lbs.
7"
1,420 lbs.
225 lbs.
7"
2,240 lbs.
425 lbs.
7"
3,600 lbs.
775 lbs.
12"
3,600 lbs.
3,600 lbs.

3"

0.223"

4"

0.223"

B16 Straight Coil Loop Insert

To Order:
Specify: (1) quantity, (2) name,
(3) bolt diameter, (4) length,
(5) finish.

Example:
6"

0.306"

200, B16 Straight Coil Loop


Inserts, 1/2" dia. x 6" long,
electro-plated finish

Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.

Lifting/Handling
Inserts
and Accessories

Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for
lifting/handling of precast panels.
B

B17 Double Flared Coil Loop Insert DS_B17

The design of the B17 insert leaves an open space between the two loops, allowing
the B17 insert to straddle reinforcing steel or prestressing strands.
Standard sizes are shown in the chart and other sizes are
available on special order.
Minimum spacing between inserts is twice the minimum corner
distance.

The safe working load of the B17 Double Flared Coil Loop Insert is greatly increased
over that of a B18 Single Flared Coil Loop. This increase in capacity is achieved by
welding a second loop to the same coil. By adding the additional loop, it doubles
the cross-sectional area of steel embedded in the concrete and at the same time,
increases the area of the shear cone.

B17 Double Flared Coil Loop Insert

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) length, (5) finish.

Example:
400, B17 Double Flared Coil Loop Inserts, 1-1/4"
dia. x 12-3/8" long, plain finish.

B17 Double Flared Coil Loop Insert Selection Chart


Bolt
Diameter
1"
1-1/4" or
1-1/2"
1"
1-1/4" or
1-1/2"

Minimum
Edge
Distance
5"
9"
12"
18"
5"
9"
12"
18"

Minimum
Corner
Distance
15"
15"
18"
27"
15"
15"
18"
27"

Safe
Working Load
Tension
4,910 lbs.
9,500 lbs.
9,500 lbs.
9,500 lbs.
4,950 lbs.
9,810 lbs.
11,150 lbs.
13,500 lbs.

Safe
C
D
A
B
Working Load
Shear
2,780 lbs.
6,720 lbs.
12-3/8" 0.375" 5-9/16" 5-9/16"
9,500 lbs.
9,500 lbs.
2,940 lbs.
7,120 lbs.
12-1/2" 0.440" 5-3/4" 5-3/4"
10,960 lbs.
13,500 lbs.

Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.

84

11/12

Lifting and Handling Inserts


B18 Single Flared Coil Loop Insert DS_B18
The load carrying capacity of any cast-in-place concrete insert is largely
dependent upon the ability of the insert to draw upon the tensile strength
of the mass of concrete within which it is embedded. The B18 Single Flared
Coil Loop Insert makes effective use of this principle by increasing the depth
and width of concrete embedment.

B18 inserts are available with an optional B3 Screw-on Coil for use with the
B30 Screw-on Plastic Cone which acts to set the insert back from the face of
the concrete.

B18 Single Flared Coil Loop Insert


Minimum
Corner Distance
or Greater

Minimum spacing between inserts is twice the corner distance.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) length,
(5) finish.

Make certain
setting bolt is of
sufficient length to
form a cavity for
lifting bolt.

Example:

Minimum
Edge Distance
or Greater

200, B18 Single Flared Coil Loop Inserts, 1" dia. x 12" long,
plain finish.
Shear Direction

Bolt
Diameter
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1-1/4"
1-1/2"

Insert
Height

Minimum
Edge Distance

Minimum Corner
Distance

Safe Working Load


Tension

SafeWorking Load
Shear

4"

5"

10"

2,250lbs.

1,510lbs.

4"

8"

10"

2,250lbs.

2,250lbs.

6"

5"

10"

2,930lbs.

1,770lbs.

6"

12"

12"

3,750lbs.

3,750lbs.

9"

5"

10"

3,750lbs.

1,770lbs.

9"

12"

12"

3,750lbs.

3,750lbs.

12"

5"

10"

3,750lbs.

1,770lbs.

12"

12"

12"

3,750lbs.

3,750lbs.

9"

5"

10"

4,500lbs.

1,960lbs.

9"

15"

15"

4,500lbs.

4,500lbs.

12"

5"

10"

4,500lbs.

1,960lbs.

12"

12"

12"

4,500lbs.

4,500lbs.

6"

5"

10"

2,920lbs.

1,960lbs.

6"

12"

12"

4,500lbs.

4,500lbs.

9"

5"

10"

4,500lbs.

1,960lbs.

9"

12"

12"

4,500lbs.

4,500lbs.

12"

5"

10"

4,500lbs.

1,960lbs.

12"

12"

12"

4,500lbs.

4,500lbs.

12"

5"

12"

5,970lbs.

2, 130lbs.

12"

14"

14"

7,500lbs.

7,500lbs.

12"

7"

10"

7,500lbs.

3,530lbs.

12"

7"

14"

7,500lbs.

3,530lbs.

12"

7"

10"

7,500lbs.

3,530lbs.

12"

14"

14"

7,500lbs.

7,500lbs.

4"

1-3/16"

3"

0.223"

6"

1-5/8"

5-1/2"

0.306"

9"

1-5/8"

5-1/2"

0.306"

12"

1-5/8"

5-1/2"

0.306"

9"

1-3/4"

5-5/8"

0.375"

12"

1-3/4"

5-5/8"

0.375"

6"

1-7/8"

5-5/8"

0.375"

9"

1-7/8"

5-5/8"

0.375"

12"

1-7/8"

5-5/8"

0.375"

12"

2-1/4"

5-7/8"

0.440"

12"

2-1/2"

5-7/8"

0.440"

12"

2-3/4"

5-7/8"

0.440"

Safe Working Loads are based on 1/2" setback from face of concrete.
Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.

11/12

85

Lifting/Handling
Inserts
and Accessories

B18 Single Flared Coil Loop Insert

Lifting and Handling Inserts


B33 Double Flared Coil Loop Insert

DS_B33

The safe working load of the B33 Double Flared Coil Loop Insert is identical to
that of the B17 Double Flared Coil Loop. However, its crisscross design will not
allow the insert to straddle reinforcing steel or prestressing strands.

D
C

Standard sizes are shown in the chart and other sizes are available on special
order. Minimum spacing between inserts is twice the minimum corner distance.

B33 Double Flared Coil Loop Insert

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) length,
(5) finish.

Example:
400, B33 Double Flared Coil Loop Inserts, 1-1/4" dia. x 12-3/8"
long, plain finish.
B33 Double Flared Coil Loop Insert Selection Chart
Bolt
Diameter
1"
1-1/4" or
1-1/2"

Lifting/Handling
Inserts
and Accessories

1"
1-1/4" or
1-1/2"

Minimum
Edge
Distance
5"
9"
12"
18"
5"
9"
12"
22"

Minimum
Safe
Safe
A
B
C
D
Corner
Working Load Working Load
Distance
Tension
Shear
15"
4,910 lbs.
2,780 lbs.
15"
9,500 lbs.
6,720 lbs.
12-3/8" 0.375" 5-9/16" 5-9/16"
18"
9,500 lbs.
9,500 lbs.
18"
9,500 lbs.
9,500 lbs.
15"
4,870 lbs.
2,940 lbs.
15"
9,650 lbs.
7,100 lbs.
12-1/2" 0.440" 5-3/4" 5-3/4"
18"
10,960 lbs.
10,940 lbs.
22"
13,500 lbs.
13,500 lbs.

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.

F47 Double Flared Loop Insert DS_F47

3/4" Coil

The Dayton Superior F47 Double Flared Loop Insert has been designed for use in
3-1/4" or thicker precast concrete elements. This insert is available for use with
3/4" diameter coil bolts only.
2-3/4"
Minimum
Height

To Order:
Specify: (1) quantity, (2) name, (3) finish.

.223" Diameter

Example:
200, F47 Double Flared Loop Inserts, plain finish.
4-5/8"

Bolt Diameter Safe Working


x
Load
Insert Height
Tension

3/4" x 2-3/4"

2,750 lbs.

Concrete
Strength

Minimum
Edge
Distance

2,500 psi

6"

8"

3-1/

F47 Double Flared Loop Insert

Safe Working Load provides a factor of safety of approximately 4 to 1 in


normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of the concrete.

86

11/12

Lifting and Handling Inserts


F48 Eye Nut, F49 Eye Bolt and F49A Eye Bolt

DS_F48F49F49A
The Dayton Superior F48 Eye Nut is cast from ductile iron that meets ASTM Standard A-536
Grade 80-55-06. The eye nut is cast with coil threads and is intended to be used with B12 Coil
Rod that has been cut to the proper length. The eye nut eliminates the need to inventory several
different lengths of eye bolts.
To make permanent length eye bolts, it is possible to weld lengths of coil rod to the casting.
Since improper welding techniques can result in reduced safe working loads, Dayton Superior
recommends that you contact your local welding supply house for proper welding instructions
and techniques.

F48 Eye Nut

The F49 Eye Bolt is an F48 Eye Nut supplied with a specified length of coil rod that has been
welded in place. In order to develop the F49 eye bolts rated load, the shoulder must be
tightened securely against the face of the concrete.
The F48 Eye Nut and F49 Eye Bolt are intended for straight tensile loading only; pulling or lifting
at an angle drastically reduces the safe working load and is not recommended.
F48 Eye Nut and F-49 Eye Bolt Selection Chart
Safe Working
Load
Tension

Coil Rod
Diameter

2,700 lbs.

1/2"

3-1/4"

1"

1"

3/4"

2"

3,600 lbs.

3/4"

3-1/2"

1-1/4"

1"

3/4"

2"

7,200 lbs.

1"

5"

1-1/4"

1-3/4"

1"

3"

10,800 lbs.

1-1/4"

6-1/4"

1-1/2"

2-1/4"

1-1/4"

4"

Weld
Area

Length

Dimensions

Coil
Thread

To Order F48 Eye Nut:

To Order F49 or F49A Eye Bolts:

Specify: (1) quantity, (2) name,


(3) bolt diameter.

Specify: (1) quantity, (2) name, (3) bolt diameter,


(4) length.

Example:

Example:

200, F48 Eye Nuts, 1" dia. bolt.

200, F49 Eye Bolts, 1" dia. X 12" long.

Lifting/Handling
Inserts
and Accessories

Safe Working Load provides a factor of safety of approximately 5 to 1.


Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.

F49 Eye Bolt


A
B

The F49A Eye Bolt is a forged, carbon steel, one piece, shoulder pattern eye bolt. It is available with 3/4"
or 1" diameter coil threads and stocked in 3-1/2" and 6" lengths. Other lengths are available special order.
In order to develop the F49A Eye Bolts rated load, the shoulder must be tightened firmly against the
face of the concrete. The eye bolt is intended for straight tensile loading only; pulling or lifting at an
angle drastically reduces the safe working load and is not recommended. The F49A Eye Bolt meets
material requirements of ASTM Standard A-489.

Length

F49A Eye Bolt

F49A Eye Bolt Selection Chart


Bolt
Diameter

Tension
Safe Working
Load

3/4"

3,600 lbs.

2-7/8"

1-1/2"

3" or 6

1"

6,400 lbs.

3-1/2"

1-3/4"

3"

Length

Safe Working Load provides a factor of safety of approximately 5 to 1.

11/12

87

Lifting and Handling Inserts


P21 Wire Rope Loop

DS_P21

The P21 Dayton Superior Wire Rope Loop provides a fast method for handling precast items. Designed
to work with 3/4" and 1" diameter coil inserts under straight tension loads only. Do not use under shear
loading conditions, instead, use a swivel lift plate and coil bolt. With proper care, the wire rope loop can be
reused. Visual evidence of any deterioration of the wire rope is a safety feature of this product.
A

Diameter x
Type of Thread

Safe Working
Load Tension

Loop Dimensions
A

1/2" Coil

2,000lbs.

6"

2"

1 - 1/4"

3/4" Coil

5,200lbs.

8 - 3/4"

2 - 1/2"

1 - 3/4"

1" Coil

8,000lbs.

12"

3"

2 - 1/4"

Safe Working Load provides a factor of safety of approximately 5 to 1.

Diameter

P21 Wire Rope Loop

To Order:
Specify: (1) quantity, (2) name, (3) diameter.

Example:
100, P21 Wire Rope Loop, 3/4" dia.coil.

F53 Thin Slab Coil Insert DS_F53


Lifting/Handling
Inserts
and Accessories

The Dayton Superior F53 Thin Slab Coil Insert is designed for lifting thin
precast concrete panels from the casting bed and for handling the panels
until they are set into their final position. Inserts should be set back 1/2"
from the surface of the concrete, maintaining at least 3/4" of concrete
below the insert. Minimum spacing between inserts is twice the minimum
corner distance. Available in insert heights up to 4".

A
C
A

15
A

F53 Thin Slab Coil Insert


F53 Thin Slab Coil Insert Selection Chart
Bolt
Diameter

Insert
Height

Minimum
Edge
Distance

Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear

3/4"

3"

8"

12"

2,340 lbs.

2,340 lbs.

3"

7-1/8"

0.306"

1"

4"

10"

15"

3,520 lbs.

3,460 lbs.

4"

9-3/8"

0.306"

1-1/4"

4"

10"

15"

3,520 lbs.

3,460 lbs.

4"

9-5/8"

0.306"

1-1/2"

4"

10"

15"

3,520 lbs.

3,460 lbs.

4"

9-7/8"

0.306"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) height, (5) finish.

Example:
200, F53 Thin Slab Coil Inserts, 1" dia. x 4" height,
plain finish.

88

11/12

Lifting and Handling Inserts


F56, F58 and F60 Expanded Coil Inserts

Expanded Coil Inserts are fabricated in two, four or six strut versions, as required. A
standard coil is welded at one end of the strut wires and on the opposite end, an
expanded pitch coil is welded. The expanded pitch coil welded to the more deeply
embedded end of the insert, serves to distribute the applied loads over a larger
volume of concrete.

Ethafoam Plug installed when mounting washers are ordered.

Minimum spacing between inserts is twice the minimum corner distance.

Longer lengths available, if required.

Expanded Pitch Coil


A

F56 Expanded Coil Insert


for Coil Threaded Bolts

DS_F56F58F60

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) finish.

Example:
200, F60 Expanded Coil Inserts, 1-1/2" diameter,
plain finish.

Insert
Type

Bolt
Diameter

Insert
Length

F56
Coil

3/4"

4-1/2"

F56
Coil

1"

5-1/2"

F58
Coil

1-1/4"

7-1/2"

F60
Coil

1-1/2"

9-1/2"

Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
6"
1,800 lbs.
680 lbs.
8"
2,220 lbs.
1,380 lbs.
12"
4,250 lbs.
2,760 lbs.
20"
4,250 lbs.
4,250 lbs.
7"
2,000 lbs.
740 lbs.
9"
2,560 lbs.
1,500 lbs.
12"
5,300 lbs.
3,250 lbs.
24"
6,250 lbs.
6,250 lbs.
10"
2,480 lbs.
1,270 lbs.
12"
3,600 lbs.
2,730 lbs.
15"
5,700 lbs.
4,790 lbs.
26"
10,480 lbs.
10,590 lbs.
12"
2,820 lbs.
1,500 lbs.
15"
3,880 lbs.
3,230 lbs.
15"
6,680 lbs.
6,260 lbs.
30"
14,580 lbs.
16,430 lbs.

4-1/2"

0.375"

1-1/2"

5-1/2"

0.440"

2-1/2"

7-1/2"

0.440"

2-3/4"

9-1/2"

0.440"

3-5/8"

Lifting/Handling
Inserts
and Accessories

Expanded Coil Insert Selection Chart


Minimum
Edge
Distance
2-1/2"
4"
8"
14"
2-1/2"
4"
8"
16"
3"
5"
8"
18"
3"
5"
8"
22"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe Working Load is based on a 1/2" setback from face of concrete.

11/12

89

Lifting and Handling Inserts


F63 Flared Thin Slab Coil Insert DS_F63
The Dayton Superior F63 Flared Thin Slab Coil Insert is designed for use in very
thin slabs or other conditions where a longer insert cannot be used. Inserts
should be set back 1/2" from the surface of the concrete, maintaining at least
3/4" of concrete below the insert. Minimum spacing between inserts is twice the
minimum corner distance.

C
B

F63 Flared Thin Slab Coil Insert

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) height, (5)
finish.

Example:
200, F63 Flared Thin Slab Coil Inserts, 1" dia. x 4-1/2" plain finish.
F63 Flared Thin Slab Coil Insert Selection Chart
Bolt
Insert
Diameter Height

Minimum
Edge
Distance

Minimum
Safe
Safe
Corner Working Load Working Load
Distance
Tension
Shear

Lifting/Handling
Inserts
and Accessories

1/2"

1-3/4"

6"

6"

1,520 lbs.

1,090 lbs.

1-3/4"

4-1/8"

0.223"

3/4"

2-5/16"

8"

8"

2,170 lbs.

1,640 lbs.

2-5/16"

4-7/8"

0.306"

3/4"

3-1/2"

9"

9"

3,570 lbs.

2,600 lbs.

3-1/2"

4-7/8"

0.306"

1"

2-5/16"

8"

8"

2,460 lbs.

1,970 lbs.

2-5/16"

5-1/4"

0.306"

1"

4-1/2"

12"

12"

5,280 lbs.

4,000 lbs.

4-1/2"

5-1/4"

0.306"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.

F65 Type L Coil Insert

DS_F65

The Dayton Superior F65 Type L Coil Insert is designed for use in lifting and handling
lightweight precast concrete elements. Inserts should be set back 1/2" from the
surface of the concrete. Minimum spacing between inserts is twice the minimum
corner distance.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.

Example:
200, F65, Type L Coil Inserts, 1/2" diameter, plain finish.
A

F65 Type L Coil Insert


F65 Type L Coil Insert Selection Chart
Bolt
Diameter

Insert
Length

1/2"

4"

3/4"

4"

Minimum
Edge
Distance
2-1/2"
5"
8"
2-1/2"
5"
8"

Minimum
Corner
Distance
10"
10"
12"
10"
10"
12"

Safe
Working Load
Tension
1,150 lbs.
2,250 lbs.
2,250 lbs.
1,140 lbs.
2,630 lbs.
3,520 lbs.

Safe
Working Load
Shear
530 lbs.
1,230 lbs.
1,980 lbs.
600 lbs.
1,400 lbs.
2,250 lbs.

4"

2-3/8"

0.223"

4"

3-3/8"

0.306"

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Note: Dayton Superior does not recommend the use of 1/2" diameter bolts for lifting/handling of precast panels.
Note: Chart based on Face Lift usage of inserts.

90

11/12

Lifting and Handling Inserts


T1 Single Pickup Insert DS_T1

Dayton Superior T1 Single Pickup Inserts are available with plastic or stainless
steel tips and with or without T21 Insert Locator Plugs installed. T1 inserts are
designed for use with T12 or T26 Swivel Lifting Plates. Do not use T1 inserts
as an edge or end pick-up insert.
Height of insert is 3/8" less than the panels structural thickness. Standard
panel thickness is shown in the chart and other panel thickness is available on
special order.
Minimum spacing between inserts is twice the minimum corner distance.
T1 Single Pick-up Insert Selection Chart

3/4"

1"

1-1/4"

1-1/2"

4"
5"
6"
7"
8"
4"
5"
6"
7"
8"
4"
5"
6"
7"
8"
4"
5"
6"
7"
8"

Minimum
Edge
Distance
9"
11"
12"
14"
16"
10"
12"
13"
14"
16"
10"
12"
14"
15"
15"
12"
14"
14"
15"
16"

Minimum
Safe
Safe
Corner
Working Load Working Load
Distance
Tension
Shear
9"
2,360 lbs.
2,360 lbs.
16"
3,540 lbs.
3,540 lbs.
18"
4,880 lbs.
4,880 lbs.
21"
6,350 lbs.
6,350 lbs.
24"
7,950 lbs.
7,950 lbs.
10"
2,450 lbs.
2,450 lbs.
12"
3,650 lbs.
3,650 lbs.
16"
5,000 lbs.
5,000 lbs.
21"
6,480 lbs.
6,480 lbs.
24"
8,080 lbs.
8,080 lbs.
10"
2,540 lbs.
2,540 lbs.
14"
3,750 lbs.
3,750 lbs.
15"
5,110 lbs.
5,110 lbs.
18"
6,610 lbs.
6,610 lbs.
24"
8,200 lbs.
8,200 lbs.
12"
2,640 lbs.
2,640 lbs.
14"
3,860 lbs.
3,860 lbs.
16"
5,230 lbs.
5,230 lbs.
21"
6,740 lbs.
6,740 lbs.
24"
8,200 lbs.
8,200 lbs.

T1 Single Pickup Insert

To Order:
Specify: (1) quantity, (2) name, (3) diameter,
(4) panel structural thickness, (5) type of tips.

Example:
200, T1 Single Pickup Inserts, 3/4" dia., 5"
panel structural thickness, plastic tipped feet.

Lifting/Handling
Inserts
and Accessories

Panel
Bolt
Diameter Thickness

Safe Working Load provides a factor of safety of approximately 4 to 1 in 3,000psi normal


weight concrete.

11/12

91

Lifting and Handling Inserts


T3 and T3A End Pickup Inserts DS_T3T3A
.375" Diameter
Loop for Tension

.375" Diameter
Loop for Tension

12"

12"
.375"
Diameter
Shear Bar

.375" Diameter
Shear Bar

5-3/4"

12"
5-1/2"

23"

11-1/2"

T3 End Pickup Insert

T3A End Pickup Insert

T3 and T3A End Pickup Insert Selection Chart

Lifting/Handling
Inserts
and Accessories

Insert
Type

Bolt
Diameter

Load
Condition

4"
Panel

5"
Panel

5-1/2"
Panel

6"
Panel

6-1/2"
Panel

7"
Panel

7-1/2"
Panel

8"
Panel

T3A

3/4"
Single

Tension

1,500 lbs.

Shear

1,250 lbs.

T3A

1"
Single

Tension

3,000 lbs. 3,300 lbs. 3,600 lbs. 3,900 lbs. 4,200 lbs. 4,500 lbs. 4,500 lbs.

Shear

1,350 lbs. 1,375 lbs. 1,400 lbs. 1,425 lbs. 1,450 lbs. 1,500 lbs. 1,550 lbs.

T3

3/4"
Double

Tension

2,500 lbs.

Shear

1,500 lbs.

1"
Double

Tension

4,000 lbs. 4,400 lbs. 4,800 lbs. 5,200 lbs. 5,600 lbs. 6,000 lbs. 6,000 lbs.

Shear

2,100 lbs. 2,250 lbs. 2,400 lbs. 2,550 lbs. 2,700 lbs. 2,850 lbs. 3,000 lbs.

T3

Safe working load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.

To Order:
Specify: (1) quantity, (2) name, (3) diameter.

Example:
200, T3 End Pickup Inserts, 1" diameter.

92

11/12

Lifting and Handling Inserts


T7S and T7ST Slotted Setting Studs
The Dayton Superior T7S Slotted Setting Stud has a slot to facilitate
installation and removal. The T7ST stud has a slot and is drilled 1" deep and
tapped with 1/4"-20 threads to allow the stud to be used as an insert setting
plug.

Used with standard coil threaded inserts to provide void for B14 coil bolts.

Made from continuous threaded steel rod.

Top is cut off square so screed can pass over.

Threads and slot should be coated with non-staining lubricant to


prevent bonding.

Loosen studs within 2 to12 hours after concrete placement to ease


removal when ready to lift.

Standard steel sizes are 1/2", 3/4", 1", 1-1/4" and 1-1/2" diameter x 4"
long. Other lengths available on request.

P25 Plastic Setting Bolt

Length

Length

T7S

T7ST

To Order:
Specify: (1) quantity, (2) name, (3) diameter.

Example:
200, T7S Slotted Setting Studs, 1" diameter.

DS_P25

The Dayton Superior Plastic Setting Bolt is used to attach 1/2", 3/4" and 1" diameter coil inserts to wood
frames. The head of the setting bolt has nail holes allowing easy attachment of the bolt. The plastic setting
bolt positions the insert 3/4" from concrete surface.
Bolt
Diameter

Length
Thread

100210

1/2"

2"

100220

3/4"

3-1/4"

100230

1"

4-3/4"

To Order:
Specify: (1) quantity, (2) name, (3) diameter.

Lifting/Handling
Inserts
and Accessories

Product Code

Length
Thread

Example:
200, P25 Plastic Setting Bolt, 1" diameter.

T8 Lifting Angle DS_T8


Designed for use with T2 Double Pickup Inserts.

May be use for face lifting inserts and edge lifting inserts when panel thickness
exceeds 6".

Cut washers are required under head of all bolts.

Made from structural steel angle in the sizes shown below.

Safe Working Load is 18,000lbs.

12"
D

T8 Lifting Angle

Bolt
Diameter

Clevis
Hole

1"

18"

12"

6"

4"

5/8"

1-3/4" dia.

1-1/4"
1-1/2"

21"

15"

6"

6"

3/4"

1-1/2" dia.

11/12

To Order:
Specify: (1) quantity, (2) name, (3) bolt
diameter.

Example:
200, T8 Lifting Angles, 1-1/4" bolt diameter.

93

Lifting and Handling Inserts


T10 and T11 End Pickup Inserts DS_T10T11T10 or T11 End Pickup Insert Selection Chart
Insert Length

0.440"

B
B
12"
12"
24"

6"

1/2"

0.440"

6"

A
1/2"

0.440"

T10 Single End Pickup Insert

0.440"

T11 Double End Pickup Insert

To Order:
Specify: (1) quantity, (2) name, (3) length, (4) struts.
Lifting/Handling
Inserts
and Accessories

Example:
200, T11 Single End Pickup Inserts, 1" dia. x 9" height, 4 struts.
Insert
Type

Bolt
Diameter

No. of
Struts
Wires

Insert
Length

Minimum
Corner Distance

Safe Working
Load Tension

Safe
Working
Load Shear

Minimum
Panel
Thickness

T10

1"

9"

11"

3,660lbs

1,300lbs

9"

9"

3-1/16"

T10

1-1/4"

10"

9"

3,870lbs

1,520lbs

10"

10"

3-5/16"

T10

1"

9"

11"

3,660lbs

1,680lbs

9"

9"

3-1/16"

T10

1"

12"

14"

5,540lbs

2,740lbs

12"

12"

3-1/16"

T10

1"

15"

18"

7890lbs

3,950lbs

15"

15"

3-1/16"

T11

1"

9"

15"

7,250lbs

2,450lbs

9"

9"

3-1/16""

T11

1-1/4"

10"

15"

6,190lbs

2,740lbs

10"

10"

3-5/16"

T11

1"

9"

15"

8,730lbs

3,180lbs

9"

9"

3-1/16"

T11

1"

12"

19"

11,640lbs

4,570lbs

12"

12"

3-1/16"

T11

1"

15"

19"

12,390lbs

6,070lbs

15"

15"

3-1/16"

Safe working load provides a factor of safety of approximately 4 to 1 in 3,000 psi normal weight concrete.
Safe working load based on 0 setback from face of concrete.

94

11/12

Lifting and Handling Inserts


Proper Installation of T3 and T11 End Pickup Inserts
When using end pickup inserts, a 1/2" thick wood washer, length of plastic pipe or cut washers must be used against the
ends of the loops. This is necessary so that when the lifting plate is tightened down, it will bear against the concrete and
not against the loop ends. This procedure is necessary to develop the safe working load of the end pickup inserts. End
pickup inserts must be located in the center of the panel structural thickness to obtain their safe working load.
Form cavity for lifting
bolt with Insert Locator
Plug or setting bolt.

Cut Washers or
1/2" Thick Wood Washer

P
L/2

15"
Minimum
Edge
Distance

L/2

Cen
Lin ter
Stru e of
Thic ctural
knes
s

Coil Bolt
Casting Surface

L
Note: Shear Bar must be
on top of coils for T3 or
T3A inserts.

Note: To achieve Safe Working Load, Lifting


Plate must be centered on T3 or T11 Insert

Always check to make certain that you have the proper clearance under the coil to prevent the lifting bolt from bottoming
out against the concrete. You must be able to tighten the bolt securely to prevent the lifting hardware from slipping and
applying unexpected loads to the insert.
Minimum Coil Penetration
and Void

Minimum Coil
Penetration

Insert Setback

Insert Setback

Form Lumber
T27 Lifting
Plate

Required
Bolt Length

Void

Plate Thickness

Lifting Bolt

Setting Bolt

Note: Face insert lifting bolt lengths are calculated in Setting Bolt for Edge Inserts
a similar manner to that shown above.
Form Lumber
1-1/2"

Safety Notes

Insert Setback

Coils must be perpendicular to the slab


edge to achieve safe working loads shown.

Minimum Coil Penetration

Inserts must be set back 1/2" from the


concrete surface in order to achieve safe
working loads shown.

Total Bolt Length

Coil bolt penetration must agree with


minimums shown above.

11/12

Minimum Void

1/2"
2-1/2"
1/2"
5"

Lifting Bolt for Edge Inserts


T27 Plate Thickness
Insert Setback
Minimum Coil Penatration
Total Bolt Length

1"
1/2"
2-1/2"
4"

95

Lifting/Handling
Inserts
and Accessories

How To Determine Bolt Length

Lifting and Handling Inserts


T12 Swivel Lifting Plate DS_T12

Designed for use with single pickup inserts.

Can be used for face lifting or edge lifting.

Complete unit made of forged steel.

T12
Swivel
Lifting
Plate
5"

Safety Notes

1-3/8"

All plates must have full bearing on smooth, flat


surfaces.

Lifting plates must be used with a bolted fastener of


sufficient strength to develop the required loads.

Type

Lifting plates are to be used only with the bolt diameter


for which they were designed. F or example, use a 3/4"
bolt with a 3/4" T12 Swivel Lifting Plate, do not use a 3/4"
bolt with a 1", 1-1/4" or 1-1/2" T12 Swivel Lifting Plate.

T12

All Plates must be securely fastened to slabs.

For exposed aggregate panels, a grout pad is required to


provide bearing for the plate.

Coil bolt penetration must agree with minimums.

Bolt
Diameter

Safe Working
Load

Bearing Plate
Size

3/4"

7,200lbs.

1"

10,000lbs.

1/2 x 2-1/2"
x 5"

Safe Working Load provides a factor of safety of approximately 5 to 1.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Example:
10, T12 Swivel Lifting Plates, 1" bolt diameter.

Lifting/Handling
Inserts
and Accessories

T21 Insert Locator Plugs DS_T21


The Dayton Superior T21 Insert Locator Plug is a two piece plastic unit designed to
engage the top and bottom of 3/4", 1", 1-1/4" and 1-1/2" diameter insert coils. The
top piece has a protruding stem that marks the insert location. Plug removal is easily
accomplished with a screw driver or similar device. The bottom portion of the plug
forms a cavity for final bolt clearance. T21 plugs are available factory installed in the
inserts or loose for field installation.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Example:

3/4" diameter
only

10, T21 Insert Locator Plug, 1-1/4" bolt diameter.

1", 1-1/4", and


1-1/2" diameters

T21 Insert Locator Plugs

T26 Double Swivel Lifting Plate DS_T26


Designed for use with 1", 1-1/4" and 1-1/2" diameter coil bolts.

Rotates 360 in horizontal plane and 180 in vertical plane.

Round bearing plate provides maximum safety when used with any coil bolt lifting system.

Heavy forged bail is made of high-strength material.

Double swivel action allows bail to rotate in direction of applied load.

Safe Working Load is 9,000lbs. for 1" diameter.

Safe Working Load is 13,500lbs. for 1-1/4" and 1-1/2" diameter.


Type
T26
T26
T26

Bolt
Diameter
1"
1-1/4"
1-1/2"

2-11/16"
2-3/4"
2-3/4"

5"
7"
7"

Safe Working
Load
9,000
13,500
13,500

Safe Working Load provides a factor of safety of approximately 5 to 1.

96

T26 Double Swivel


Lifting Plate

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Example:
10, T26 Double Swivel Lifting Plate, 1-1/4" bolt diameter.

11/12

Lifting and Handling Inserts


T27 Edge Lifting Plate DS_T27

1" Thick

5 1/2"

Designed for use with T3 or T11 pickup inserts.

Made from structural steel plate 1" x 4" x 18" long.

Cut washers are required under head of all bolts.

For use with 3/4" or 1" diameter bolts.

For use on panels up to 6" thick; on panels thicker than 6", use T8.

Safe Working Load is 8,800lbs.

12"
18"

Warning: Never use T27 with face lift inserts.

4"

T27 Edge Lifting Plate

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Example:
10, T27 Edge Lifting Plate, 1" bolt diameter.

Dos and Donts


Do not modify, weld or alter, in any way, lifting hardware units.

Prior to lifting any precast element, apply an initial cable tension making certain that the bail or clevis attachment plate
is aligned in the direction of the load at all times. Crane line loads must not be allowed to apply a sideward load to the
bail or clevis attachment plate, as this condition is dangerous and could lead to a premature failure.

Load

Clevis
Attachment
Plate

Lifting/Handling
Inserts
and Accessories

T8 Lifting or T27 Edge Lifting Plate


Load

Clevis
Attachment
Plate

Right

Wrong

T12 Swivel or T26 Double Swivel Lifting Plates


Load

Load

Bail

Bail

Right

Wrong

Total System and Safe Working Loads


The user must be aware of the capacity of the total lifting system since the determination of the safe working load involves
concrete strength and safe working loads of the insert, bolt and lifting hardware. All must be evaluated with the lowest
safe load component determining the safe working load of the system. This handbook has such values listed in tabular
form for all components, including the minimum concrete compressive strengths that must exist at time of use. Therefore,
do not assume that an inserts safe working load is that of the system, since the Safe Working Loads of the bolt or lifting
hardware may be less than that of the insert. Examine the values of all components.
Danger! Crane line loads and bails of swivel and double swivel lifting plates must be turned in direction of crane forces
before lifting operations begin. Crane line loads must not be allowed to apply sideward loads to bails of Swivel Lifting
Plates or Clevis Attachment Plates of Lifting Angle or Lifting Plate; this condition is dangerous and could lead to failure of
hardware.

11/12

97

Notes and Sketches

98

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F5 Threaded Insert DS_F5

The Dayton Superior F5 Threaded Inserts have National Course (NC) threads and are recommended
for use under permanent loading conditions. This insert has been approved by the Board of
Standards and Appeals for use in New York City under Calendar No. 447-60SM.

The F5 insert is cast from ductile iron that meets ASTM A-395, Grade 60-40-18.

F5
Threaded Insert

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

F5 Threaded Insert Selection Chart


Bolt Diameter
and Threads
per Inch

Example:
200, F5 Threaded Inserts, 3/4" bolt diameter.

Tension Safe
Bolt
Working Load Engagement

1/2" 13

1,500 lbs.

15/16"

1-5/8"

2-1/2"

1-5/8"

5/8" 11

2,000 lbs.

3/4"

1-5/8"

3"

1-5/8"

3/4" 10

2,500 lbs.

7/8"

1-13/16"

3"

1-7/8"

7/8" 9

3,000 lbs.

1-5/16"

2-1/2"

3-3/8"

2-5/8"

1" 8

3,000 lbs.

1-5/16"

2-1/2"

3-3/8"

2-5/8"

Safe Working Load provides a factor of safety of approximately 3 to 1 when the insert is
properly embedded in 3,000 psi normal weight concrete.

F42 Loop Ferrule Insert DS_F42


The Dayton Superior F42 Loop Ferrule Insert is fabricated by welding a looped strut to
a closed-end ferrule. F42 insert is available in the sizes shown in the chart below and is
well suited for structural connections and the suspension of equipment, piping, etc.
Minimum spacing between inserts is twice the minimum corner distance.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Maximum
Bolt
Engagement

1/8"

Example:

Structural
Connectors

200, F42 Loop Ferrule Inserts, 3/4" bolt diameter.

F42 Loop Ferrule Insert


F42 Loop Ferrule Insert Selection Chart
Safe
Bolt Diameter Minimum Minimum
and Threads
Corner Working Load
Edge
Tension
per Inch
Distance Distance
1/4" 20 NC
3/8" 16 NC
1/2" 13 NC
5/8" 11 NC
3/4" 10 NC
7/8" 9 NC
1" 8 NC

Safe
Maximum Bolt
Working Load
Engagement
Shear

5"

650 lbs.

650 lbs.

5"

5"

2,000 lbs.

1,260 lbs.

10"

15"

2,000 lbs.

2,000 lbs.

5"

5"

2,000 lbs.

1,280 lbs.

7"

10"

2,000 lbs.

2,000 lbs.

5"

7"

2,200 lbs.

1,990 lbs.

8"

8"

2,200 lbs.

2,200 lbs.

5"

7"

2,200 lbs.

1,990 lbs.

8"

8"

2,200 lbs.

2,200 lbs.

8"

8"

5,300 lbs.

4,060 lbs.

10"

15"

5,300 lbs.

5,300 lbs.

8"

8"

5,300 lbs.

4,060 lbs.

10"

15"

5,300 lbs.

5,300 lbs.

5"

3/4"

2-3/4"

0.243"

3/4"

2-3/4"

0.243"

1"

2-3/4"

0.243"

1-1/8"

3-1/2"

0.258"

1-1/8"

3-1/2"

0.258"

1-1/8"

6"

0.375"

1-1/8"

6"

0.375"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.

11/12

99

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F43 Plain Ferrule DS_F43


The Dayton Superior F43 Plain Ferrule (without loops) can be furnished for
fabricating special inserts at the job site. Ferrules are manufactured from either
12L14 cold drawn carbon steel or Type 304 Stainless Steel. Contact your local
welding service for proper welding techniques and instructions on welding either of
these materials.
When ferrules are produced from Type 304 stainless steel, they will have a knurled rib,
as shown. Ferrules that do not have any knurling are produced from 12L1K steel.
Minimum bolt engagement for ferrule inserts shall be equal to the nominal bolt
diameter plus 1/8". The use of shorter bolt engagements will result in
a lower than expected load carrying capacity.

Maximum
Bolt
Engagement

Stainless Steel
Identification
Knurl

F43 Plain Ferrule

F43 Plain Ferrule Selection Chart

Bolt Diameter
and Threads
per Inch

Maximum
Bolt
Engagement

1/4" 20 NC

3/4"

1-1/4"

9/16"

3/8" 16 NC

3/4"

1-1/4"

9/16"

1/2" 13 NC

1"

1-3/8"

11/16"

5/8" 11 NC

To Order:

1-1/8"

1-5/8"

7/8"

3/4" 10 NC

1-1/8"

1-5/8"

1"

Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.

7/8" 9 NC

1-1/8"

1-5/8"

1-1/4"

All of the ferrules and ferrule inserts listed in this handbook are
tapped with National Course (NC) threads. Dayton Superior can
furnish, on special order, ferrules that are tapped with metric threads.
Note: All ferrules are made with a knock-out area in the closed
bottom. When knocked out, the hole will accept a #8-32 self
tapping screw that is used to attach ferrule inserts to the form face.

Example:
2000 pcs., F43 Plain Ferrules, 3/8" bolt diameter, type 304 SS.

1" 8 NC

1-1/8"

1-5/8"

1-3/8"

1-1/4" 7 NC

1-3/4"

2-1/2"

1-5/8"

1-1/2" 6 NC

2-1/4"

3"

1-7/8"

Special Ferrule Application


Many precasters have found that a 3/4"-10 NC threaded ferrule, when used as a nut in a special shop built insert, will
solve many of their connection problems. The safe working loads of the ferrule (nut) when it is subjected to various bolt
engagements are listed for your use.
Structural
Connectors

Note: As the Ferrule SWL's listed are based on compression loading conditions, do not attempt to use these safe working
loads with regular ferrule inserts.
Nominal Bolt
Diameter and
Threads per Inch

Minimum
Bolt
Engagement

Maximum
Safe
working Load

3/4" - 10

1/4" 7 mm

5,500lbs. 24.4 kN

3/4" - 10

3/8" 10 mm

7,200lbs. 32.0 kN

3/4" - 10

1/2" 13 mm

8,700lbs. 38.6 kN

3/4" - 10

3/4" 19 mm

10,300lbs. 45.8 kN

The SWL's provide approxiamately a 3 to 1 factor of safety against thread stripping.

The SWL's listed in the chart assume that the special


precaster built insert has the capacity to safely support
at least 3 times the ferrules safe working load.

100

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F44 Thin Slab Ferrule Insert DS_F44


The Dayton Superior F44 Thin Slab Ferrule Insert is a specially designed insert for use where the depth of embedment is
extremely limited and where there is a requirement for limited capacity in both tension and shear. Depending on region,
the F44 will be furnished with either two struts welded to the bottom of the ferrule or one strut looped around the ferrule
(see sketch). Minimum spacing between inserts is twice the minimum corner distance.
F44 Thin Slab Ferrule Insert Selection Chart

0.262"
4"

0.262"

Bolt Diameter
and Threads
Per Inch

Safe
Working Load
Tension

Maximum
Bolt
Engagement

1/4" 20 NC

450 lbs.

3/4"

1-1/4"

9/16"

3/8" 16 NC

450 lbs.

3/4"

1-1/4"

11/16"

1/2" 13 NC

900 lbs.

1"

1-3/8"

13/16"

5/8" 11 NC

1,000 lbs.

1-1/8"

1-5/8"

1-1/16"

3/4" 10 NC

1,600 lbs.

1-1/8"

1-5/8"

1-1/16"

7/8" 9 NC

1,600 lbs.

1-1/8"

1-5/8"

1-1/16"

1" 8 NC

1,600 lbs.

1-1/8"

1-5/8"

1-1/16"

Dimensions
A

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000


psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.

To Order:
4"

Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.

Example:
200, F44 Thin Slab Ferrule Inserts, 1/2" bolt diameter, plain finish.

Structural
Connectors

F44 Thin Slab Ferrule Inserts

F45 Cap Plug DS_F45


The Dayton Superior F45 Cap Plug is the least expensive device available for positioning NCthreaded inserts.
The Cap Plug is easily nailed to a wood form. Push an NC Threaded insert onto the plastic cap for a press fit.
If care is taken in the placement of concrete and in the use of vibrators, the F45 Plastic Plug is a
satisfactory mounting device. Available for use with 3/8", 1/2", 5/8", 3/4", 1" and 1-1/4" National Course
(NC) threaded inserts.

F45 Cap
Plug

To Order:
Specify: (1) quantity, (2) name, (3) size.

Example:
200, F45 Cap Plugs, 1/2" diameter.

11/12

101

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F50 Rocket/Kohler Ferrule Insert DS_F50

Length

The Dayton Superior F50 Rocket Kohler Ferrule Insert is a two-strut ferrule insert with
an extended length ferrule and integral washer face. The F50 insert is available in
diameters from 1/4" through 1-1/4" and is well suited for structural connections or
supporting hung ceilings, equipment, piping, etc.

A
B

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.

Example:
200, F50 Rocket/Kohler Ferrule Insert, 1/2" bolt diameter,
plain finish.
F50 Rocket/Kohler
Ferrule Insert
F50 Rocket/Kohler Ferrule Insert Selection Chart
Bolt Diameter
Safe
Safe
Insert Minimum Minimum
and Threads
Corner Working Load Working Load
Length Edge
Per Inch
Distance Distance
Tension
Shear

Maximum
Bolt
Engagement

1/4" 20 NC

1-3/4"

4"

6"

750 lbs.

750 lbs.

1-3/4"

0.223"

1-1/4"

3/8" 16 NC

1-3/4"

4"

6"

1,050 lbs.

1,350 lbs.

1-3/4"

0.223"

1-1/4"

1/2" 13 NC

2-1/4"

6"

9"

1,575 lbs.

1,075 lbs.

2-1/4"

0.223"

1-3/4"

5/8" 11 NC

3-3/8"

6"

11"

3,000 lbs.

3,000 lbs.

3-3/8"

0.306"

2-3/4"

3/4" 10 NC

3-3/8"

6"

11"

3,000 lbs.

3,000 lbs.

3-3/8"

0.306"

2-3/4"

7/8" 9 NC

3-3/4"

7"

12"

3,800 lbs.

3,800 lbs.

3-3/4"

0.375"

3-1/8"

1" 8 NC

3-3/4"

7"

12"

3,800 lbs.

3,800 lbs.

3-3/4"

0.375"

3-1/8"

1-1/8" 7 NC

4-1/4"

8"

14"

4,350 lbs.

4,350 lbs.

4-1/4"

0.375"

3-5/8"

1-1/4" 7 NC

4-1/4"

8"

14"

4,350 lbs.

4,350 lbs.

4-1/4"

0.375"

3-5/8"

Structural
Connectors

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.

F52 Thin Slab Ferrule Insert DS_F52


The Dayton Superior F52 Thin Slab Ferrule Insert is fabricated with four
L-shaped struts resistance-welded to an NC thread ferrule. The F52 insert
is available in 3/4" and 1" bolt diameters and in any height. Maximum
insert safe working load is developed at an insert height of 5-1/2"

1/8"

A
D

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) insert height,
(5) finish.

15
B

Example:

B
C

200, F52 Thin Slab Ferrule Insert, 1" bolt diameter, 5-1/2" height,
plain finish.

F52 Thin Slab Ferrule Insert

F52 Thin Slab Ferrule Insert Selection Chart


Minimum
Edge
Distance

Minimum
Corner
Distance

Safe
Working
Load
Tension

Safe
Working
Load
Shear

3-1/8"

8"

12"

3,680 lbs.

3,200 lbs.

3-1/8"

4-1/8"

12"

18"

5,300 lbs.

5,300 lbs.

4-1/8"

Bolt Diameter
and Threads
per Inch

Insert
Length

3/4" 10 NC
1" 8 NC

Maximum
Bolt
Engagement

3"

7"

0.306"

1-1/8"

4"

9-3/8"

0.306"

1-1/8"

Safe Working Loads provide a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.

102

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F54 Ductile Embed Insert DS_F54

The Dayton Superior F54 Ductile Embed Insert is a one-piece, integrally hot forged
unit fabricated out of smooth, round steel meeting ASTM A-29 Hot Rolled Grade 1045
requirements.
Insert top has a round washer face with four nail holes. The user can nail or bolt the insert
to side forms or wet set in face of panel as required. The bottom end has a forged, washerface hex foot to resist pullout from the concrete.
Use as a cast-in-place insert or in a core and grout insert application. Several inserts can be
laced and/or templated together to provide preset anchorage patterns for closely-spaced
multiple insert requirements.

Length

Shaft
Dia.

Longer insert lengths are available when required. Minimum spacing between the inserts,
shown in the chart, is twice the minimum corner distance.
Available plain, electro-galvanized, hot-dipped galvanized or epoxy coated as required.
F54 Ductile Embed Insert
Nail

Running Nut

Form

Setting Bolt

To Order:
Specify: (1) quantity, (2) name, (3) shaft diameter, (4) overall length.

Example:

Structural
Connectors

550, F54 Ductile Embed Insert, 3/4" x 9" long.


F54 Ductile Embed Insert Selection Chart
Bolt Diameter
Shaft
Insert
and Threads
Diameter Length
per Inch
5/8" 11 NC

3/4"

7-1/2"

3/4" 10 NC

7/8"

9"

7/8" 9 NC

1"

10-1/2"

1" 8 NC

1-1/8"

12"

1-1/4" 7 NC

1-3/8"

15"

Safe
Working Load
Tension

Safe
Minimum Minimum Flange
Maximum Bolt
Working Load
Edge
Corner Diameter
Engagement
Shear
Distance Distance
A

6,700 lbs.

4,310 lbs.

7-1/2"

15"

9,030 lbs.

5,420 lbs.

10"

18"

8,800 lbs.

5,890 lbs.

9"

18"

13,360 lbs.

8,020 lbs.

14"

20"

11,150 lbs.

8,050 lbs.

10-1/2"

18"

18,350 lbs.

11,090 lbs.

16"

24"

13,790 lbs.

10,160 lbs.

12"

24"

22,980 lbs.

14,540 lbs.

18"

30"

19,960 lbs.

15,570 lbs.

15"

30"

33,150 lbs.

20,340 lbs.

24"

36"

2"

15/16"

2-1/4"

1-1/8"

2-3/8"

1-5/16"

2-1/2"

1-1/2"

3-1/4"

1-7/8"

Safe Working Loads provide a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from the face of concrete.
Minimum spacing between inserts is twice the corner distance.
Note: Bolt diameter is 1/8" less shaft diameter all products.

11/12

103

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F57 Expanded Coil Ferrule Insert DS_F57


F59 Expanded Coil Ferrule Insert DS_F59
F61 Expanded Coil Ferrule Insert DS_F61

The Dayton Superior Expanded Coil Ferrule Inserts were developed as a more
effective means for increasing the inserts tensile capacity, without increasing
its depth of embedment. By increasing the width of the base, the volume of
the resisting shear cone is significantly increased. The expanded pitch coils
welded to the more deeply embedded end of the insert serve to distribute
the applied loads over a larger volume of concrete.

F57 Insert 2 Struts


F59 Insert 4 Struts
F61 Insert 6 Struts

Available in longer lengths, as required. Minimum spacing between inserts is


twice the corner spacing.

Expanded Coil Ferrule Loop Insert Selection Chart


Insert
Type

Bolt
Diameter
Insert
and Threads Length
per Inch

F57

3/4" 10 NC

4-5/8"

F57

1" 8 NC

5-5/8"

F59

1-1/4" 7 NC

7-5/8"

F61

1-1/2" 6 NC

9-5/8"

Minimum
Edge
Distance

Minimum
Corner
Distance

Safe
Working
Load
Tension

Safe
Working
Load
Shear

6"

9"

4,650 lbs.

2,730 lbs.

14"

20"

5,890 lbs.

5,890 lbs.

8"

12"

6,990 lbs.

4,300 lbs.

16"

24"

8,100 lbs.

8,100 lbs.

10"

15"

9,920 lbs.

7,940 lbs.

18"

26"

13,310 lbs.

13,310 lbs.

12"

18"

13,180 lbs.

12,450 lbs.

22"

30"

18,680 lbs.

18,680 lbs.

Maximum
Bolt
Engagement

4-5/8"

2-1/8"

1-1/2"

0.375"

1-1/8"

5-5/8"

2-3/4"

2-1/4"

0.440"

1-1/8"

7-5/8"

3"

2-3/4"

0.440"

1-3/4"

9-5/8"

3-3/8"

3-5/8"

0.440"

2-1/4"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on insert 1/2" setback from the face of concrete.

Structural
Connectors

Minimum spacing between inserts is twice the corner.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) finish.

Example:
200, F61 Expanded Coil Ferrule Inserts, 1-1/2" dia., plain finish.

104

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F62 Flared Thin Slab Ferrule Insert DS_F62


The F62 Flared Thin Slab Ferrule Insert was designed for use in thin precast concrete elements or for conditions where a
longer insert cannot be used. This insert is closed at the back end of the ferrule to keep concrete from getting into the
threads. The ferrule will accept only NC threaded bolts of appropriate diameters.
1/8"

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter, (4) insert height,
(5) finish.
A

Example:
1, 000 pcs., F62 Flared Thin Slab Ferrule Insert, 1" bolt x 2-7/16"
high, plain finish.

F62 Flared Thin Slab Ferrule Insert


F62 Flared Thin Slab Ferrule Insert Selection Chart
Minimum
Corner
Distance

Safe
Working
Load
Tension

Safe
Working
Load
Shear

6"

9"

2,120 lbs.

7"

10"

2,900 lbs.

6"

9"

9"

14"

6"
11"

Insert
Height
(A)

Minimum
Edge
Distance

1/2" 13 NC

1-7/8"

5/8" 11 NC

2-7/16"

3/4" 10 NC

2-7/16"

3/4" 10 NC

3-5/8"

1" 8 NC

2-7/16"

1" 8 NC

4-5/8"

Bolt Diameter
and Threads
per Inch

Maximum
Bolt
Engagement

2,120 lbs.

2"

4-3/4"

0.223"

1"

2,900 lbs.

2-"

4-3/4"

0.306"

1-1/8"

2,960 lbs.

2,960 lbs.

2"

4-7/8"

0.306"

1-1/8"

4,830 lbs.

4,830 lbs.

2"

4-7/8"

0.306"

1-1/8"

9"

3,080 lbs.

3,080 lbs. 2-3/16" 5-1/8"

0.306"

1-1/8"

16"

6,780 lbs.

6,780 lbs. 2-3/16" 5-1/8"

0.306"

1-1/8"

11/12

Structural
Connectors

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from face of concrete.
Minimum spacing between inserts is twice the corner spacing.

105

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F64 Ferrule Loop Insert DS_F64

1/8"

The Dayton Superior F64 Ferrule Loop Insert is manufactured by


welding a wire loop to a steel ferrule which has been machined
from bar stock. One end of the ferrule is closed, while the other
end is drilled and tapped to accept an NC threaded bolt.
Typically, this insert is used to attach a precast wall panel to a
building frame, as well as provide attachment of other structural
elements that may be required.

Mounting Washer Option for all Ferrule Type Inserts


All ferrule type inserts are available with a 16 gauge x 2" x 2"
mounting washer as an option. The mounting washer allows you
to nail a ferrule type insert to the form.
To keep concrete from entering the threaded portion of an insert
F64 Ferrule Loop
with mounting washer, cover the open face of the washer with
Insert
duct tape.
F64 Ferrule Loop Insert Selection Chart

Structural
Connectors

Bolt Diameter
and Threads per
Inch

Insert
Height (A)

1/2" 13 NC

4-1/8"

1/2" 13 NC

6-1/8"

5/8" 11 NC

4-1/8"

5/8" 11 NC

6-1/8"

3/4" 10 NC

4-1/8"

3/4" 10 NC

6-1/8"

7/8" 9 NC

6-1/8"

1" 8 NC

6-1/8"

1" 8 NC

8-1/8"

Minimum
Edge Distance

Minimum
Corner
Distance

Safe Working
Load Tension

Safe Working
Load Shear

5"

10"

3,000lbs.

1,810lbs.

9"

15"

3,000lbs.

3,000lbs.

7"

12"

5,000lbs.

3,410lbs.

9"

12"

5,000lbs.

3,410lbs.

5"

10"

3,000lbs.

1,810lbs.

9"

12"

3,000lbs.

3,000lbs.

7"

12"

5,000lbs.

3,420lbs.

11"

15"

5,000lbs.

5,000lbs.

5"

10"

3,000lbs.

1,810lbs.

9"

12"

3,000lbs.

3,000lbs.

7"

12"

5,000lbs.

3,420lbs.

11"

15"

5,000lbs.

5,000lbs.

7"

12"

5,000lbs.

3,420lbs.

11"

15"

5,000lbs.

5,000lbs.

7"

12"

5,000lbs.

3,420lbs.

11"

12"

5,000lbs.

4,650lbs.

7"

12"

5,000lbs.

3,830lbs.

11"

15"

5,000lbs.

5,000lbs.

Insert with Optional


Mounting Washer.

Maximum Bolt
Engagement

0.223"

1"

0.306"

1"

0.223"

1-1/8"

0.306"

1-1/8"

0.223"

1-1/8"

0.306"

1-1/8"

0.306"

1-1/8"

0.306"

1-1/8"

0.306"

1-1/8"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete.
Safe Working Loads are based on 1/2" setback from the face of the concrete.
Minimum spacing between inserts is twice the minimum corner distance.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter,
(4) insert length, (5) finish.

Example:
200, F64 Ferrule Loop Insert, 5/8" bolt diameter,
6-1/8" insert length, plain finish.

106

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

F72 Threaded Setting Plug DS_F72


The Dayton Superior F72 Threaded Setting Plugs eliminate the
need for putting large holes in formwork in order to secure the
inserts to the forms. Basically a socket set screw, it is drilled
through and tapped with #8-32 thread. It can be nailed to
wood forms, or bolted to steel forms using an #8-32 threaded
bolt. The reusable plugs are easily removed using a standard
hex wrench.

To Order:
Specify: (1) quantity, (2) name, (3) diameter.

Example:
200, F72 Threaded Setting Plugs, 3/4" diameter.

Nail or
#8-#32
Screw

Tapped
Internally with
#8-32 Thread

Dia.

F72 Threaded Setting Plug


F72 Selection Chart
Bolt Diameter
and Threads
per Inch

3/8" 16 NC

3/8"

3/16"

1/2" 13 NC

3/8"

1/4"

5/8" 11 NC

1/2"

5/16"

3/4" 10 NC

5/8"

3/8"

1" 8 NC

1"

9/16"

Dimensions

F74 Threaded Plastic Plug DS_F74


The Dayton Superior F74 Threaded Plastic Plug is manufactured with National Course (NC) threads to fit 3/8", 1/2", 5/8",
3/4", 7/8" and 1" NC threaded inserts. A hole is provided through the plug that may be used to attach (nail) the plug to
the form.

To Order:
Specify: (1) quantity, (2) name, (3) bolt diameter.

Example:

F74 Threaded
Plastic Plug
Structural
Connectors

200, F74 Threaded Plastic Plugs, 3/4" diameter.

11/12

107

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

P87 Star Adapter Plug DS_P87

The Dayton Superior P87 Star Adapter Plug is available in all Star
Insert diameters. The P87 plug is a setting plug for installing the
insert into precast forms. Its use effectively seals the insert against
concrete seepage.

To Order:
Specify: (1) quantity, (2) name,
(3) diameter.

Example:
200, Star Adapter Plugs, 3/4"
diameter.

Before each use, coat the side of the plug as well as the threaded
portion with a form release or water resistant grease. This will allow
P87 Star
Adapter Plug
the plug to be easily removed from the concrete.

The plug may be ordered with a 1/8"diameter smooth hole, for use in nailing to wood forms or a #8-32 threaded
hole for attaching to steel forms.
P87 Star Insert Adapter Plug
Insert
Designation

Size

Product
Code

P25A

3/8"

9525003

3/4"

1/4"

P35A

1/2"

9535003

1"

1/4"

P45A

5/8"

9545004

1-1/8"

3/8"

P55A

3/4"

9555003

1-1/4"

3/8"

Nail
#8-32
Wood Form

Typical Installations

Steel Form

P88 Star Holzin Insert DS_P88

The Dayton Superior P88 Star Holzin Insert is a 1/2" nominal


diameter, die cast zinc alloy insert for corrosion-free precast concrete
applications. Threads are set back 1" from open end of insert.

P88 Star Holzin Insert Selection Chart

Structural
Connectors

Bolt
Diameter
and Threads
Per Inch

Safe Working
Load Tension

1/2" 13 NC

550 lbs.

2-3/8"

1"

P88 Star Holzin Insert

T
Thread
Depth

2-5/32" 1-1/8"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,500


psi normal weight concrete.

Closed End

Closed End

To Order:
Specify: (1) quantity, (2) name.

Example:
Wood
Form

Stronghold
Nail

200, P88 Star Holzin Inserts.


Wood
Form

Product Code 2355003


Bolt Diameter Threads
per Inch
Bolt

Typical Installations

Insert Length A
Length B

2=3/8"
7/8"

Width C

1-1/4"

Outer Diameter D

11/16"

Thread Length T

1-1/8"

Total Depth L

2=5/32"

Torque (ft.lbs.

19

Safe Working Load in


3,500psi Concrete

108

1/2" - 13 NC

550lbs.

11/12

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

P90 Connecting Systems Nylon Threaded Inserts DS_P90

Dayton Superior P90 Connecting Systems Threaded Inserts are mineral-filled nylon inserts designed
for attaching, suspending and fastening objects to precast concrete. They provide the precast
manufacturer with an excellent, cost effective fastening system.

Advantages:

Economical

Light weight

Easy to handle and use

Available in five bolt diameters

Can be used in hundreds of applications

Typical Applications:

Lifting insert for light loads

Secure handles of burial vaults

Secure mechanical equipment to concrete pads

Secure telephone booths to concrete pads

Fasten cable holders to utility poles

Secure benches, picnic tables and other landscape items to concrete bases

Suspend pipes, conduits and other utilities from concrete panels and ceilings

Plus many, many others

Steel
Form

P90

Insert
Length
(A)

Minimum
Edge
Distance

Minimum
Corner
Distance

Safe
Working
Load
Tension

Safe
Working
Load
Shear

1/4" 20 NC

1-1/2"

1"

3/4"

3"

6"

1,000 lbs.

1,000 lbs.

3/8" 16 NC

1-1/2"

1"

3/4"

3"

6"

1,075 lbs.

1,075 lbs.

1/2" 13 NC

1-5/8"

1-3/8"

3/4"

3-1/2"

7"

1,175 lbs.

1,175 lbs.

1/2" 13 NC

2-5/8"

1-3/8"

3/4"

5-1/2"

11"

2,525 lbs.

2,525 lbs.

5/8" 11 NC

3"

1-1/2"

7/8"

6"

12"

3,375 lbs.

3,375 lbs.

3/4" 10 NC

3-1/4"

1-5/8"

1"

6-1/2"

13"

3,625 lbs.

3,625 lbs.

Structural
Connectors

Steel Installation Using Bolt

P90 Connecting Systems Threaded Insert Selection Chart


Bolt
Diameter
and Threads
per Inch

Bolt

Safe Working Loads provides a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.
Minimum spacing between inserts is twice the corner distance.

11/12

109

NC Threaded Inserts
For Suspending, Connecting and Anchoring to Concrete

D108A Headed Dowel Bar Insert DS_108


The Dayton Superior D108A Dowel Bar Insert is a one-piece unit integrally forged from
material meeting ASTM A-615 Grade 60 requirements. This insert works extremely well
in areas of heavy rebar congestion and provides excellent anchorage provisions for light
standards, signs, posts, fixtures, etc. The D108A Headed Dowel Bar Insert is approved by
the International Code Council, evaluation report ICC #4028.

The top of the insert has a round washer face with four nail holes. Nail or bolt insert to side
forms or wet set in face of panel as required. The bottom end has a hot-forged, washer
face hex foot to resist pull-out from the concrete.
Length

Use this versatile insert as a cast-in-place insert or in a core and grout application. Lace and/
or template several inserts together to provide repeat anchorage patterns of two, three,
four or more inserts.
Longer length inserts are available as required. Minimum spacing between the inserts
shown in the chart is twice the minimum corner distance.
Available plain, electro-galvanized, hot-dipped galvanized or epoxy coated as required.

D108A Headed
Dowel Bar Insert

To Order:
Specify: (1) quantity, (2) name, (3) bar size,
(4) overall length, (5) finish.

Example:
300, D108A Headed Dowel Bar Insert,
#5 x 7-1/2" long, plain finish.

Laced and Template Application

Structural
Connectors

Core and Grout Application


D108A Headed Dowel Bar Insert Selection Chart
Bolt
Shaft
Diameter
and Threads Diameter
per Inch

Insert
Length

Safe
Working
Load
Tension

Safe
Working
Load
Shear

Minimum
Edge
Distance

Minimum
Corner
Distance

7-1/2"

6,000 lbs.

4,000 lbs.

8"

12"

Flange
Maximum
Diameter
Bolt
A
Engagement

5/8" 11 NC

#4

3/4" 10 NC

#5

9"

9,300 lbs.

6,200 lbs.

11"

15"

2"

1"

7/8" 9 NC

#6

10-1/2"

13,200 lbs.

8,800 lbs.

13"

20"

2-1/4"

1-1/8"

1" 8 NC

#7

12"

18,000 lbs.

12,000 lbs.

16"

24"

2-7/16"

1-1/4"

1-7/8"

7/8"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 3,000 psi normal weight concrete concrete as calculated from
criteria in ACI 318. Specific applications are the responsibility of the Engineer of Record, not Dayton Superior.
Minimum spacing between inserts is twice the corner distance.
Insert Length to bottom of bolt head.

110

11/12

Sleeve-Lock Grout Sleeve


DS_SleeveLock
D410 Sleeve-Lock Grout Sleeve
The Dayton Superior Sleeve-Lock Grout Sleeve is a one-piece mechanical
coupler designed to butt-splice reinforcing steel in concrete structures.
The Sleeve-Lock is available in seven (7) sizes to accommodate deformed
bar sizes #4 through #18. Bars of like size or of different sizes can
be effectively spliced by the System. Typical Sleeve-Lock applications
include precast and cast-in-place concrete structures.
The Sleeve-Lock is a ductile casting with a minimum yield strength of 55,000 psi and a minimum tensile strength of 80,000
psi. It exceeds all known building codes and agency standards. The System achieves 160% fy strength criteria with the
Sleeve-Lock Grout D490 high strength, non-shrink grout.
The Sleeve has several unique features:

Rebar Stop An integrated post that acts as a precise stop when inserting rebar

Alignment Fins Positioning fins that keep inserted rebar centered

Standard Port Sizes Ports designed to accept standard 0.75" SCH40 PVC; ports use the same size PVC

Stacking Feet Feet used to stabilize the product during shipping and on the shelf while assisting in wire-tying and
acting as a platform for a rebar chair.

Made In USA The sleeve is 100% made in the USA.


SLEEVE-LOCK DIMENSIONS

REBAR EMBEDMENT LENGTH

E, MAX

E, MIN

F, MAX

F, MIN

#4

13MM

2.14

1.26

0.87

2.14

9.50

0.25

4.63

3.30

4.63

3.30

#5

16MM

2.14

1.26

0.87

2.14

9.50

0.25

4.63

4.13

4.63

4.13

#6

19MM

2.61

1.73

1.14

2.61

13.00

0.25

6.38

4.92

6.38

4.92

#7

22MM

2.61

1.73

1.14

2.61

13.00

0.25

6.38

5.71

6.38

5.71

#8

25MM

2.89

2.01

1.42

2.89

16.52

0.38

8.07

6.50

8.07

6.50

#9

29MM

2.89

2.01

1.42

2.89

16.52

0.38

8.07

7.40

8.07

7.40

#10

32MM

3.04

2.16

1.57

3.04

17.99

0.50

8.75

8.19

8.75

8.19

#11

36MM

3.32

2.32

1.73

3.32

19.54

0.50

9.52

8.98

9.52

8.98

#14

43MM

3.73

2.60

2.01

3.73

24.50

0.50

12.00

11.42

12.00

11.42

#18

57MM

4.77

3.27

2.68

4.77

36.00

0.50

17.75

17.00

17.75

17.00

All dimensions are in inches

D490 Sleeve-Lock Grout


Sleeve-Lock Grout D490 is specifically designed and manufactured by DSC for the
Sleeve-Lock System. It is a flowable grout capable of achieving 11,000ksi when
mixed following the recommended mixing instructions of DSC. Available in 50lb
bags, yield per bag, noting that grout used in PVC tubing is not accounted for, is
as shown in table:
Use only potable water for mixing. A 50 pound (22.7 kg) of grout will require
approximately 6.5 pints (3.07 liters) of water to achieve a flowable consistency.
The water amount can be adjusted +/- 0.5 pints (0.23 liters) to achieve desired
consistency. Determine correct water amount by mixing of a test batch prior to
commencing grouting operation.

SLEEVES
PER BAG OF
GROUT

SIZE
#4

13MM

37

#5

16MM

40

#6

19MM

16

#7

22MM

30

#8

25MM

11

#9

29MM

11

#10

32MM

#11

36MM

#14

43MM

#18

57MM

Amounts are approximate.

11/12

111

Structural
Connectors

SIZE

Sleeve-Lock Grout Sleeve


D487 Sleeve-Lock Seal Plug
The Sleeve-Lock Seal Plug is a rubberized plug used to seal the connection between the Sleeve-Lock
Grout Sleeve and the reinforcing bar. It is designed to keep concrete from entering the inner cavity of
the Sleeve-Lock Grout Sleeve on the Factory End and to contain the pumped in grout on the Field End.
Per size, the Sleeve-Lock Seal Plug can be used on either end meaning that only one size Sleeve-Lock
Seal Plug (QTY 2) per sleeve need be stocked.

D491 Sleeve-Lock Form Plug


The Sleeve-Lock Form Plug is a device using a rubberized grommet and a clamping device and used to attach
the Sleeve-Lock Grout Sleeve to a piece of formwork i.e. steel, lumber, composite. It is designed to fasten the
sleeve to the formwork while keeping concrete out of the sleeves inner chamber. It is to be used on the Field
End only and is not designed to be used as a structural connection.

D492 Sleeve-Lock " SCH40 PVC


The Sleeve-Lock " SCH40 PVC is standard, off the shelf, PVC, used to fill the inner chamber of the
Sleeve-Lock Grout Sleeve. Either port of the sleeve uses the same size PVC. It is available locally or
through DSC.

D493 Sleeve-Lock Port Plug


The Sleeve-Lock Port Plug is a plastic plug used during jobsite shipping to plug the ports in order to keep debris
from entering the inner chamber of the sleeve. They can also be used to plug the PVC before or after grouting.
One size will fit either end port or PVC.

How to Specify:

Structural
Connectors

Specific: Mechanical splices shall be the SleeveLock


Grout Sleeve System manufactured by Dayton Superior
Corporation.
Generic: The mechanical connection shall meet building
code requirements of developing in tension and
compression, as required, by local standards and codes.
Grouting must be performed in accordance with the
manufacturer's recommended grouting procedures.

112

11/12

Threaded Splicing Systems


Dowel Bar Splicer System* DS_DowelBarSplicer
ICC Evaluation Report No. 4028
The Dayton Superior Dowel Bar Splicer System is a
two-piece, standard mechanical splicing technique
(splicing bars of equal size) that eliminates
protruding dowels. Typical applications include
splicing reinforcement bars in precast structures,
rebar anchorages, future expansion, and dowel bar
substitution at construction joints.
The components of the system, the Splicer and
Dowel-In, are manufactured from standard grade 60
rebar material. Basic fabrication consists of forging
*U.S. Patent No. 4,619,096
and threading operations. No welding or machining
is required and the threading operation does not
reduce the nominal cross-sectional area of the bar.
The completed splice (joined Splicer and Dowel-In) obtains ultimate bar strengths and meets or exceeds all existing code
requirements including 160% fy or 95% of bar actual tensile requirements as identified by ICC acceptance criteria AC 133.

System Advantages
The patented Dowel Bar Splicer System has been engineered, tested and proven to meet or exceed all field standards
and design/engineering practices. The System is strong, easy to use and readily identified as rebar material. The easy
installation requires no special tools or machinery and simplifies the forming operations. There are no extras, such as
wedges, nuts, collars or couplers required and routine cutting, bending, etc., can be easily handled in the field, if required.
The Dayton Superior Dowel Bar Splicer System Advantages:

Strong

Safe

Easy to Use

Eliminates Protruding Dowels

Improves Forming Costs

Reduces Forming and Stripping Hassles

Saves Forms By Eliminating Drilling Holes

No Forming Required

System Compliance

International Conference of Building Officials (ICC Report #4028)

City of Los Angeles Research Report RR 24518

American Concrete Institute (ACI Standard 318)

State Departments of Transportation

Corps of Engineers (Specification CW03210)

Miscellaneous
Connection Inserts

The Dowel Bar Splicer System complies with the following standards/specifications:

Typical Splicing Specification


The Dayton Superior Dowel Bar Splicer System, consisting of the Dowel Bar Splicer and Dowel-In, shall be used in splicing
of rebar. The Dowel Bar Splicer shall be forged from ASTM A-615 grade 60 deformed rebar material, free of external
welding and machining. It shall be furnished with an integral nailing flange and threaded with UNC or UN thread to a
depth equal to the nominal thread diameter. The Dowel-In shall be fabricated from ASTM A-615 grade 60 deformed rebar
material with thread corresponding to the Splicer. The completed splice shall meet 160% fy exceeding tensile requirements
of American Concrete Institute Specification 318, Building Code Requirements for Reinforced Concrete and the Corps of
Engineers Specification CW03210, Civil Works Construction Guide Specification for Steel Bars, Welded Steel Wire Fabric and
Accessories for Concrete Reinforcement.
Note: For more information on the threaded Dowel Bar Splicer System, request a copy of the Dayton Superior Rebar
Splicing Handbook

11/12

113

Bar Lock Rebar Coupler System


Dayton Superior BarLock Coupler System* DS_BarLockCoupler
ICC Evaluation Report No. 5064
The Dayton Superior BarLock Coupler System provides a simple, quick, cost effective method for splicing rebar in tension
and/or compression applications. BarLock couplers may be used with plain or deformed bars in sizes #4 through #18.
BarLock couplers utilize lock-shear bolts and special grip rails to mechanically splice with the rebar. The serrated grip rails
cradle the rebar and are embedded in the rebar as the lock-shear bolts are tightened. The heads of the lock-shear bolts are
designed to shear off at a prescribed torque in order to accomplish proper installation.

System Advantages:

Quick and easy to install saves time and money.

Eliminates bar threading and/or special bar end treatment.

No special installation equipment required.

High strength in tension, compression and seismic applications.

Available in standard, transition and weldable versions in #4 through #18 sizes.

Ideal for new construction and rehab projects.

System Compliance
BarLock couplers are test-certified to exceed the requirements of, are
prequalified and approved, or recognized by the following building
approval agencies:

State Departments of Transportation

International Conference of Building Officials (ICC)

Building Officials and Code Administrators


(BOCA)

Southern Building Code Congress


International (SBCCI)

American Concrete Institute (ACI)

Concrete Reinforcing Steel Institute (CRSI)

City of Los Angeles Department of Building and Safety

Typical BarLock Coupler


System Splice
*U.S. Patent No. 4,666,326 and
5,046,878

BarLock coupler source material is fabricated under ISO9000 quality standards. BarLock couplers are tested by
independent, certified testing laboratories in four modes of testing: tension, compression, fatigue and cyclic. All tests are
done to the requirements of ICC and/or Caltrans requirements utilizing ASTM A615 grade 60 rebar material. Copies of test
reports are available on request.
Miscellaneous
Connection Inserts

Typical Specification
By specific name:

BarLock Mechanical Coupler System manufactured by Dayton Superior Concrete Accessories.

By generic description:

Mechanical butt splices utilizing lock-shear bolts and internal serrated grip rails within the coupling sleeve. They shall
exceed the specification requirements for both tension and compression specified by ACI 318 and the Uniform Building
code, and be recognized by the International Conference of Building Officials (ICC).

Note: For more information on the BarLock Coupler System, request a copy of the Dayton Superior Rebar Splicing Handbook

114

11/12

Other Connection Inserts


F7 Hex Nut for Shelf Angle Inserts DS_F7HexNut
The Dayton Superior F7 Hex Nuts have NC thread, made to American standard B18.2.2 and are available
for use with 3/4" Askew Head Bolts.
F7 Hex Nut

F7 Round Cut Washer for Shelf Angle Inserts


The Dayton Superior F7 Round Cut Washers are used under the F7 Hex Nuts on shelf angle inserts.
F7 washers are Type A plain, American standard B27.2. For 3/4" nominal diameter washer, the
O.D. is 2" with a thickness of 1/8". DS_F7RoundWasher

F7 Round Cut
Washer

F9 Shimming Washers for Shelf Angle Inserts

The Dayton Superior F9 Shimming Washers are used between the Shelf Angle Insert and the clip, or
shelf angle, so solid contact can be maintained between the two. F9 shims are available with slot for the 3/4" diameter
Askew Head Bolt. DS_F7ShimmingWasher
F9 Shimming
Washer Dimensions
A

1/8"

1-7/8"

1/8"

3"

1/4"

2"

1/4"

3"

2"

To Order:
Specify: (1) quantity, (2) name, (3) finish.

Example:

200, F9 Shimming Washers, hot dipped galvanized finish.

13/16"

F9 Shimming Washer

F11 Hanger Insert and F12 Hanger Hook DS_F11F12


One of the more economical and effective devices for providing points of anchorage for
suspended ceilings is the hanger insert that can be fastened to a beam soffit by nailing
or taping. The metal shell provides a cavity and the wire clip provides the anchorage for
the attachment of ceiling suspension wires. If preferred, the Hanger Hook provides a
simple method for the attachment of perforated metal hanger straps that can be used for
the support of pipe, conduit, etc. Both insert and hook are fabricated from galvanized
material. The F12 Hanger Hook is available with 9/32" or 13/32" holes.

F11 Hanger Insert

F12 Hanger
Hook

To Order:
Specify: (1) quantity, (2) name, (3) hole size in F12.
Miscellaneous
Connection Inserts

Example:
200 each, F11 Hanger Inserts and F12 Hanger Hooks,
9/23" holes.

11/12

115

Other Connection Inserts


P30 Corewall Nut Type Slotted Insert DS_P30
P31 Corewall Strap Type Slotted Insert DS_P31
COREWALL Slotted Inserts and accessories are engineered for performance and have proven to be one of the most
advanced, adjustable inserts available on the market today. The slotted inserts feature a plastic back and a removable
plastic slot cover that keeps the insert clean and saves you valuable time during the erection process.
COREWALL slotted inserts from Dayton Superior are available in two different types, the P30 Nut Type Slotted Insert and the
P31 Strap Type Slotted Insert. Both types have tabs on each end of the insert for easy attachment to your forms.

P31 Strap Type Slotted Insert

P30 Nut Type


Slotted Insert

Miscellaneous
Connection Inserts
Fast, High Strength, Reliable Concrete Connection Inserts
The P30 Nut Type Slotted Insert uses a spring loaded, zinc-plated, heavy duty 3/4"-10 National Course (NC) threaded nut to
provide fast, efficient and reliable connections. The P31 Strap Type Slotted Insert is used with either the P32 Standard Strap
Anchor or the P33 Slotted Strap Anchor, depending upon your erection requirements. The P34 Threaded Strap Anchor is
used with the P30 Nut Type Slotted Insert.
The design of the strap anchor allows for fast installation of the anchor into the slotted insert. This speeds up the erection
process and saves valuable installation time. As part of the erection process, the strap anchor is welded to the buildings
structural frame to make a ductile connection. All COREWALL products are manufactured from a weldable grade of steel.
Dayton Superior COREWALL slotted inserts are ideal for use in precast concrete industrial wall panels, architectural panels,
structural panels or precast parking structures. The COREWALL slotted inserts are also suitable for use in seismic areas.

116

11/12

Other Connection Inserts


P30 Corewall Nut Type Slotted Insert
The Dayton Superior P30 Nut Type Slotted Insert uses a spring loaded, zinc plated, heavy duty 3/4"-10 NC threaded nut
to provide fast, efficient and reliable connections. The P30 insert can be used with standard NC threaded bolts or a P34
Threaded Strap Anchor, if a welded connection is required. P30 inserts are available in 4", 6" and 8" standard lengths with
either blue epoxy-polyester or hot dipped galvanized (HDG) finish. Type 304 or 316 stainless steel is available on request.
B

C
13/16"

P30 Corewall
Slotted Insert Nut
Type

To Order:
Specify: (1) quantity, (2) name, (3) part number, (4) finish.
For proper connection to the structural
frame of the building, use either a
3/4"-10 NC threaded bolt or rod meeting
ASTM A-325 or SAE Grade 5 Standards.

Example:
200, P30 Corewall Nut Type Slotted Inserts, #CS425, hot-dip galvanized.

Part
Tension Safe
Number Working Load
CS425
CS625
CS825
CS435
CS635
CS835
CS445
CS645
CS845

4,000 lbs.
4,000 lbs.
4,000 lbs.
5,350 lbs.
5,350 lbs.
5,350 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.

Shear Safe
Working Load

6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.
6,650 lbs.

4"
6"
8"
4"
6"
8"
4"
6"
8"

3-3/16"

2-1/2"

5-1/2"

Adjustment
E
2-1/2"

3-3/16"

2-1/2"

7-1/2"

4-1/2"

3-3/16"

2-1/2"

9-1/2"

6-1/2"

3-3/8"

3-1/2"

5-1/2"

2-1/2"

3-3/8"

3-1/2"

7-1/2"

4-1/2"

3-3/8"

3-1/2"

9-1/2"

6-1/2"

3-11/16"

4-1/2"

5-1/2"

2-1/2"

3-11/16"

4-1/2"

7-1/2"

4-1/2"

3-11/16"

4-1/2"

9-1/2"

6-1/2"

Miscellaneous
Connection Inserts

P30 Corewall Nut Type Slotted Insert Selection Chart

Safe Working Loads provide a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.

11/12

117

Other Connection Inserts


P31 Corewall Strap Type Slotted Insert P33 Corewall Slotted Strap Anchor
P32 Corewall Strap Anchor
P34 Corewall Threaded Strap Anchor
The P31 Corewall Strap Type Slotted Insert and the P30 Corewall Nut Type Slotted Insert are both quick and versatile precast
concrete connection inserts. When used with the slot running in the same direction as the applied load, the inserts act as
a tension tie to the structural frame. However, when the inserts are installed so that the slot runs 90 to the applied load,
the inserts can support both shear and tension loads. DS_P31 DS_P32 DS_P33 DS_P34
1
2

Finish: Hot dipped galvanized


(HDG) or blue epoxy-polyester
(epoxy) coating.
Optional: Inserts fabricated
from Type 304 or 316 stainless
steel are available on special
order. Specify if stainless steel
nuts are required.

3/4"

P33

2 1/8"

4" x 13/16"
slot

L
A

1/2"

P34

1-1/4"

1-1/4"

P32

1-1/16"

P31

5
4

P31 Corewall Strap


Type Slotted Insert

P32 Corewall
Strap Anchor

1.
2.
3.
4.
5.

Tabs for easy attachment to forms.


Weldable grade of steel.
Notch in strap anchor assures positive connection to insert
Slot allows adjustment for erection tolerances.
Slotted holes for extra reinforcement where required.

See following page for the minimum edge distance requirements needed to develop the tension and shear safe working
loads shown in the chart below.
P31 Corewall Strap Type Slotted Insert Selection Chart
Shear Safe Working Load

Miscellaneous
Connection Inserts

Insert Style

Tension Safe
Working Load

Up to 2' Eccentricity

Up to 3' Eccentricity

SA 1425

4,000lbs.

6,650lbs.

SA 1625

4,000lbs.

SA 1825

4,000lbs.

SA 1435

4,000lbs.

4"

4-3/16"

2-1/2"

6,650lbs.

4,000lbs.

6"

4-3/16"

2-1/2"

6,650lbs.

4,000lbs.

8"

4-3/16"

2-1/2"

5,350lbs.

6,650lbs.

4,000lbs.

4"

4-3/8"

3-1/2"

SA 1635

5,350lbs.

6,650lbs.

4,000lbs.

6"

4-3/8"

3-1/2"

SA 1835

5,350lbs.

6,650lbs.

4,000lbs.

8"

4-3/8"

3-1/2"

Safe Working Load provides a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete. Eccentricity is measured from face of insert to
midpoint of the weld connecting the strap anchor to the structural frame.

Corewall Strap Anchor Selection Chart


P32 Standard
Strap Anchor

P33 Slotted
Strap Anchor

P34 Threaded
Channel Strap Anchor

P34 Threaded
Plate Strap Anchor

Part Number

Length

Part Number

Length

Part Number

Length

Part Number

Length

CE 806

6"

CE 906

6"

CE 675

6"

CE 600

6"

CE 808

8"

CE 908

8"

CE 875

8"

CE 800

8"

CE 810

10"

CE 910

10"

CE 1075

10"

CE 1000

10"

CE 812

12"

CE 912

12"

CE 1275

12"

CE 1200

12"

Note: Longer lengths are available on special order. The P34 Threaded Strap Anchor is used with the P30 Nut Type Slotted Insert and P38 Slotted Insert II.

118

11/12

Other Connection Inserts


P38 Corewall Slotted Insert II DS_P38
Product Description:
The Corewall Slotted Insert II is the next generation product in the Corewall
legacy. The design has been improved to create a higher load capacity
and greater ease to install the product. With six different product options
and two different finishes, the Corewall Slotted Insert II will meet any
application. This product is an addition to the Corewall Slotted Inserts
which have been specified and used by precasters for over 20 years. The
existing styles of Corewall Inserts remain available for use as well.

Product Specification:

7 guage one piece steel tampered body

One piece plastic void former and removable plastic cap

3/4" - 10 special nut deisgn

3 Insert heights - 2.5", 3.5", and 4.5"

3 Insert lengths - 4", 5", 6'

P34 Threaded Strap Anchor for attatchment to building frame

TECHNICAL DATA:
P38 Nut Type Slotted Anchor Insert Selection Chart
Description

Tension Safe
Working Load

Shear Safe
Working Load

Length (A)

Width (B)

Depth (C)

Length (D)

Adjustment (E)

2.5" x 4" P38

4,660lbs.

5,150lbs.

4"

5-1/2"

2-1/2"

5-1/4"

2-1/2"

2.5" x 6" P38

5,500lbs.

6,400lbs.

6"

5-1/2"

2-1/2"

7-1/4"

4-1/2"

2.5" x 8" P38

5,500lbs.

7,300lbs.

8"

5-1/2"

2-1/2"

9-1/4"

6-1/2"

3.5" x 4" P38

6,300lbs.

8,600lbs.

4"

6"

3-1/2"

5-1/4"

2-1/2"

3.5" x 6" P38

6,750lbs.

8,700lbs.

6"

6"

3-1/2"

7-1/4"

4-1/2"

3.5" x 8" P38

7,100lbs.

8,700lbs.

8"

6"

3-1/2"

9-1/4"

6-1/2"

4.5" x 4" P38

8,600lbs.

10,700lbs.

4"

6-1/2"

4-1/2"

5-1/4"

2-1/2"

4.5" x 6" P38

8,800lbs.

10,950lbs.

6"

6-1/2"

4-1/2"

7-1/4"

4-1/2"

4.5" x 8" P38

9,100lbs.

10,950lbs.

8"

6-1/2"

4-1/2"

9-1/4"

6-1/2"

Safe Working Loads provide a factor of safety of approximately 3 to 1 in 5,000 psi normal weight concrete.
Engineer is responsible to make sure that connecting threaded rod or bolt is strong enough to carry these loads.

Miscellaneous
Connection Inserts

To Order:
Specify: (1) quantity, (2) name, (3) part number,
(4) description, (5) finish.

4.5" x 6" Insert with J-Coating finish

11/12

119

Other Connection Inserts


New Corewall Edge and Corner Details
Minimum edge distance, without the use of additional reinforcing steel, is shown below. Edge distance can be reduced if
additional reinforcing steel is installed in the insert slots, as shown.

8"

12"

A variety of configurations of extra reinforcing bars can be


easily placed through the slotted holes in the legs of he
insert. This allows the insert to be used in seismic areas, as
well as close to corners or edges of a precast concrete panel.

8"

12"

Corner Detail

Edge Perpendicular
Detail

3/4" Min.
Cover

3"

3/4"
Minimum
Cover

1-1/4"

Slot Detail

1-1/4"
4"
or 6"

2"

2"

4" Insert

3/4" Min.
Cover

2#4
Stepped
Hairpins

3#4
Stepped
Hairpins

Plan

Plan

1-1/2"

3"

1-1/2"

6" Insert

3"

1-1/4"
C

1-1/2"
5/8"

3/4" Min.
Cover

2-1/2"

Edge Parallel Detail


Miscellaneous
Connection Inserts

3/4" Min.
Cover

Section
Corner Detail
3/4" Min.
Cover

4" or
6"

4" or 6"

3"

3 #4
Stepped
Hairpins

Plan

Varies to
suit min.
cover

1-1/4"

#4
Rebar
1'-6"

3/4" Min.
Cover

Plan

11/16"

Stepped Hairpin

1-1/4"

3"

2#4
Stepped
Hairpins

2-1/2"

8" Insert

3/4" Min. Cover

3/4" Min. Cover

Section

3"

3-1/2"
Out/Out

Half Stepped Hairpin

Varies

#4
Rebar
1'-6"

3/4" Minimum Cover

Section

120

3/4" Minimum Cover

Section

1-3/4"
Out/Out

11/12

Other Connection Inserts


P12D Dur-O-Web Shear Reinforcement DS_P12
The Dayton Superior P12D Dur-O-Web is a prefabricated structural web reinforcement
assembly that has been developed to replace conventional U-shaped and closed stirrups.
The vertical steel wires provide reinforcement for the applied shear stresses. The double,
horizontal side wires at the top and bottom of the assembly develop the required
anchorage for the vertical wire reinforcement. The design of Dur-O-Web allows the spacing
and size of both the vertical and horizontal wires to vary to meet your design requirements.

Availability
Dayton Superior Dur-O-Web is shipped in bundles containing 500 ft. (50 pcs. of 10'-0"
long units). Lengths other than 10'-0" can be supplied on special order. The standard
finish is bright basic. Galvanized wire, hot dipped galvanized and epoxy coated finishes
are also available on special order.

P12D Dur-O-Web
Shear Reinforcement

While Dur-O-Web is normally supplied with uniform spacing of vertical wires, variable spacing is available.

Benefits

Ideal shear reinforcement for use in prestressed/precast concrete double tees or other precast elements having narrow
webs or where space is limited.

Wide variety of wire sizes and spacings.

Ready to use.

Reduces costs by eliminating the cutting and bending of standard rebars or mesh.

Easy to place.

Available in standard 10'-0" lengths

Serves as a mesh support in double tee flanges

The ability to vary wire diameters and spacing guarantees the most economical solution to your reinforcement requirements

Approvals
The use of Dayton Superior Dur-O-Web Shear Reinforcement to replace open and closed stirrups is allowed by American
Concrete Institute (ACI-318) Standard Building Code Requirements for Concrete Structures, and Canadian Standards
Association Standard CAN3A23.3 Design of Concrete Structures for Buildings.

Using the Selection Table


The P12D Dur-O-Web selection table, shown below, shows the diameter and area of the vertical shear reinforcement wires
that are available. It also lists the minimum size horizontal anchor wire that ASTM standards require. In addition, the area
of shear reinforcement per foot is shown for the various spacing of the vertical shear reinforcement selected.
A required shear steel area of 0.100 sq. in. per foot can be provided by using 1 gauge vertical wires spaced at 7-1/2" centers
with 7 gauge longitudinal side wires. This example would provide 0.101 sq. in. of steel reinforcement per foot. Another
solution would be the use of 5 gauge vertical wires spaced at 4" centers with 10 gauge longitudinal side wires. This
combination would provide 0.102 sq. in. of reinforcement per foot.
P12D Dur-O-Web Selection Chart
Wire
Size
W-7.4
W-6.3
W-5.4
W-4.9
W-4.7
W-4.0
W-3.4
W-2.9
W-2.5
W-2.1
W-1.7
W-1.4

11/12

Wire
Wire
Gauge Diameter
0
1
2
1/4"
3
4
5
6
7
8
9
10

0.306"
0.283"
0.263"
0.250"
0.244"
0.225"
0.207"
0.192"
0.177"
0.162"
0.148"
0.135"

Steel
Minimum
Weight
Area
Side Wire
lb. per ft.
(sq. in.)
Gauge
0.074
0.063
0.054"
0.049"
0.047"
0.040"
0.034"
0.029"
0.025"
0.021"
0.017"
0.014"

0.251
0.214
0.184
0.167
0.158
0.135
0.114
0.098
0.084
0.070
0.059
0.049

Area of Steel (sq. in.) per Lineal Foot at Indicated Main Shear Reinforcement Spacing
2"

3"

11"

12"

0.444

0.296

0.222 0.178

0.148

0.127 0.118

0.111

0.099 0.089

0.081

0.074

0.378

0.252

0.189 0.151

0.128

0.108 0.101

0.095

0.084 0.076

0.069

0.063

0.324

0.216

0.162 0.130

0.108

0.093 0.086

0.081

0.072 0.065

0.059

0.054

0.294

0.196

0.147 0.118

0.098

0.084 0.078

0.074

0.065 0.059

0.053

0.049

0.282

0.188

0.141 0.113

0.094

0.081 0.075

0.071

0.063 0.056

0.051

0.047

10

0.240

0.160

0.120 0.096

0.080

0.069 0.064

0.060

0.053 0.048

0.044

0.040

10

0.202

0.136

0.102 0.082

0.068

0.058 0.054

0.051

0.045 0.041

0.037

0.034

10

0.174

0.116

0.087 0.070

0.058

0.050 0.046

0.044

0.039 0.035

0.032

0.029

10

0.150

0.100

0.075 0.060

0.050

0.043 0.040

0.038

0.033 0.030

0.027

0.025

10

0.126

0.084

0.062 0.050

0.042

0.036 0.034

0.032

0.028 0.025

0.023

0.021

10

0.102

0.068

0.051 0.041

0.034

0.029 0.027

0.026

0.023 0.020

0.019

0.017

10

0.084

0.056

0.042 0.034

0.028

0.024 0.022

0.021

0.019 0.017

0.015

0.014

4"

5"

6"

7"

7-1/2"

8"

9"

10"

121

Miscellaneous
Connection Inserts

Example:

Other Connection Inserts


P12D Dur-O-Web Shear Reinforcement
Material Specifications
Dayton Superior Dur-O-Web is manufactured with smooth, round vertical steel wires and smooth, round horizontal side
wires. All materials and products conform to the latest edition of one or more of the following ASTM specifications:

A-82 Standard Specification for Steel Wire, Plain, for Concrete Reinforcement

A-185 Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement

Weight Calculation
The sample calculation, below, shows how to calculate the approximate weight of steel used in different Dur-O-Web assemblies:

P12D Dur-O-Web
Vertical wires:

1 gauge at 6" centers

Horizontal side wires:

4 pcs. of 7 gauge

Height:

22" overall

Length"

Vertical wires = 22" 12" per ft. x 12" per ft. 6"
centers x .214 lb. per ft. x 10 ft.

Side Wires = 4 pcs. x 0.084 lb. per ft. x 10 ft.

3.36 lb.

Total weight per 10 ft. unit

11.23 lb.

10'-0"
2" Minimum

7.87 lb.

Dur-O-Web

Dur-O-Web
A H D

1" Concrete
Cover Assumed

2" Minimum

Bridge Beams

Double Tee

Dimension
"A"

P12D Dur-O-Web
Overall Height "H"

8'

2'

6'

10'

4'

8'

12'

6'

10'

14'

8'

12'

16'

10'

14'

18'

12'

16'

20'

14'

18'

22'

16'

20'

24'

18'

22'

32'

26'

30'

Miscellaneous
Connection Inserts

Depth of Concrete
Member "D"

Vertical Shear
Reinforcement

Horizontal Side
Wires

2"
Minimum

2"
Minimum
Spacing

Spacing

To Order:
Specify: (1) quantity, (2) overall height H, (3) name,
(4) gauge and spacing of vertical wires, (5) gauge of side wires,
(6) overall length (7) finish.

Example:
275, 22" high, P12D Dur-O-Web, 1 gauge verticals at 6" centers,
7 gauge side wires x 10 ft. long, bright basic finish.

122

11/12

Sandwich Panel Connectors


P24 Delta Tie

DS_P24

The Dayton Superior P24 Delta Tie is a unique insulated precast concrete panel
connector. It allows the precaster to fabricate a highly energy-efficient, insulated
precast concrete sandwich wall panel using the insulating foam of his choice.
This versatile connector allows the foam insulation to be placed from panel edge
to panel edge, eliminating thermal bridges and costly energy loss. The foam
insulation is sandwiched between two concrete wythes, or layers, to form a longlasting, energy-efficient precast concrete sandwich wall panel. The three wythes
are tied together using P24 Delta Ties. Spacing of the Delta Ties varies, based on
the panels required composite moment capacity.

P24 Delta Tie


The Delta Tie is produced using an engineered composite matrix. It consists of a
U.S. Patent #6761007
geometrically configured, two-dimensional truss manufactured from continuous
wound fiberglass embedded in an alkali resistant resin. The design of the Delta Tie produces a connector of remarkable
strength and durability.
The non-metallic, non-corrosive design of the Delta Tie eliminates any thermal transfer through the panel, increasing the
insulating efficiency of the panel.

Advantages
Increased load bearing.

Stiffer insulated panels, easier to handle.

Design flexibility.

Material, labor and transportation cost reduction.

Quick and easy installation.

Applicable to all brands of foam panel insulation.

Sandwich Panel
Connectors

11/12

123

Sandwich Panel Connectors


P24 Delta Tie

1/2" Typ.

The standard Delta Tie dimensions are shown in the accompanying detail.
The connector is designed so that it can be oriented in the panel either on end or side,
depending on the thickness of the panel. For example, the 5" x 7" size can be used on
its side in a six-inch panel or on end for thicker panels. The Delta Tie can be used with
any rigid insulation from 1" to 4" thick. This versatile, dual-use feature adds to the
Delta Ties effective application compatibility and, at the same time, reduces inventory
and storage requirements.

5"

3"

5"

In individual connector specimen and full size panel tests the Delta Tie has exhibited
excellent loading behavior and load capacities.

7"

Increased Load Bearing


Tests have verified the excellent tension and shear strength characteristics of the Delta Tie insulated panel connector.

Stiffer Insulated Concrete Panels


The inherent capabilities of the truss design greatly increase the stiffness of the panel. The added stiffness makes the panel
easier to lift, handle, store and/or transport.

Design Flexibility
Due to the composite action gained by using the Delta Tie, panels may be cast in longer lengths or with thinner concrete
wythes.

Cost Savings
The Delta Tie design provides a fast and easy installation to save labor. It produces stiffer panels to lessen handling,
storage and transportation concerns. The connectors design flexibility allows the cost saving attributes to be designed
into the panel. Delta Tie connectors are purchased as a separate item, allowing the precaster to provide the foam
insulation of his choice.

Quick and Easy Installation


The two-dimensional design of the Delta Tie lends itself to easy installation. No drilling or special tools required. Simply
use the foam as a straight-edge template to quickly place the connectors.

Applicable to All Brands of Foam Panel Insulation


The Delta Tie is not sold as part of a package. It is sold separately and can be used with any brand of foam insulation
supplied by the precaster.
The many Delta Tie advantages open up a wide area of possibilities for the precaster/designer/producer to improve
production, efficiency and costs at his precasting operation.
The P24 Delta Tie has the following ultimate capacities:

3,220lbs. in shear.

3,100lbs. in tension.

Maximum recommended spacing is 8 square feet of panel per panel connector. For spacing in excess of 8 square feet of
panel per connector, contact a Dayton Superior Technical Assistance.

NFPA 285

ASTM E-119

Five Test Approved

To Order:
Specify: (1) quantity, (2) name.

Sandwich Panel
Connectors

Example:
500, P24 Delta Ties.

124

11/12

Sandwich Panel Connectors


P24 Delta Tie Design Chart
Notes:

Percent Composite Action (k)

60%

When composite action


is not required, maximum
connector spacing for a
3"-2-3" panel is 8 sq. ft. per
connector.

Ipc = Partial Composite Moment of Inertia


k = Percentage Composite
Icomp = Composite Moment of Inertia
Inc = Non-Composite Moment of Inertia

50%

40%

Ipc = k(Icomp Inc) + Inc


100

30%

Test reports are available


on request.

20%

10%

0%

10

Square Feet Per Connector

Typical Delta Tie Placement


25% Composite Action

No Composite Action

4 sq. ft. per connector

8 sq. ft. per connector

Composite Moment Capacity


For any given sandwich panel, the shear and moment diagrams define the required panel stiffness. The panel stiffness may
be altered, as necessary, pending panel parameters, by adjusting the tie distribution as a function of the internal shear and
moment forces. The two examples, below, illustrate the required stiffness (percent composite action) necessary to develop
the shear and moment forces.
200000

1. A panel measuring 37'-0" long by 6'-0"


wide, with a 3-2-3 wythe pattern, must
have a 5% composite action to achieve
a flat lift with 4x2 rigging.

14000
12000

2-2-2

10000

Sandwich Panel
Connectors

In order to employ the least amount of


concrete to save weight, the percent of
composite action must increase. A small
upward adjustment can be realized by a
minimal addition of connectors strategically
placed at the zones of maximum shear.

Chart based on 6'-0'' Panel Width


f'c = 5,000 psi
fba = 424 psi

16000

Moment Capacity (ft-lbs)

2. A 2-2-2 panel of same size requires a


10% composite action for the same
rigging.

3-2-3

18000

8000
6000
4000
2000
0

0%

10%

20%

30%

40%

50%

60%

70%

Percent Composite

11/12

125

Sandwich Panel Connectors


P24 Delta Tie Insulated Panel Installation Sequence

Sandwich Panel
Connectors

1. Construct form, place


reinforcing mesh, lifting
inserts, etc. Place and screed
the concrete for the bottom
wythe.

2. While the bottom wythe


concrete is still pliable, lay
the first course of insulating
foam flush against the form.
Typically, the first course of
foam will be 12'' running the
length of the panel. Utilize
the edge of the foam as a
template and push each Delta
Tie down into the bottom
wythe.

3. Continue to place the


connectors in their proper
positions along the first course
of insulation.

4. Add the remaining courses of


insulation and connectors.*

5. When all of the foam sections


and connectors have been
placed, the top concrete wythe
is poured and screeded as
necessary.

6. After proper concrete set, the


panel may be removed from
the form and the process
repeated.

* Foam-backed tape is available for sealing


the insulation joints, if necessary.

126

11/12

Sandwich Panel Connectors


P12G Welded Wire Girders DS_P12G
Dimension of Diagonal Wire Over
Top/Bottom Wires

Top Wire

Diagonal
Wire

Height

3.937"

Bottom Wire

3.937"
7.875"

The growth of energy-efficient construction has guided


the precast concrete industry to design and produce costeffective and time-saving wall panel techniques.

INSTALLATION

Federal and state energy regulations have driven the


popularity of sandwich panel walls which feature a layer
of insulation sandwiched between layers of concrete.

2. Pour bottom width concrete, raise or rotate single


girder to a vertical position such that 23 of the girder is
standing out of concrete.

Dayton Superior offers the P12G Welded Wire Girder


as one method to meet the need for a unique shear
connector adequate to properly transfer or distribute loads
between panels.

3. Install insulation board in strips between the girder and


walk along the insulation board, pressing the insulation
board in and around the girder diagonal wires. If any
gaps or spaces occur, tape or caulk gaps to prevent
concrete from bridging between bottom and top
widths.

Most importantly, Welded Wire Girder not only connects the


concrete widths through the insulation material, but has
the resiliency to expand and contract with the independent
thermal-induced movements of the outer width.

4. Install top width mesh and tie to girder, or to prestressed cables for support and proper positioning in
center of top width. Place remaining concrete to form
top width.

Top Wire:

Height:

How to Order:

Minimum: 4GA 0.225" diameter

Maximum: 0GA 0.306" diameter

Length:

3" to 9" in increments of "

Bottom Wire:

Minimum: 4GA 0.225" diameter

Finish:

Maximum: 0GA 0.306" diameter

3'-11" to 34'-5"
Plain or mill galvanized

Diagonal Wire:

Pricing:

Minimum: 6GA 0.192" diameter

Maximum: 3GA 0.243" diameter

11/12

Quantity, name, height, length,


wire diameters (top/bottom/
diagonal), dimensions of diagonal
over top/bottom wire, finish (top/
bottom/diagonal).

Manufacturing Location:

Kankakee, Illinois

Sandwich Panel
Connectors

Dayton Superior girder prevents undesirable energy transfer


by eliminating solid concrete sections in the entire panel
no high stress points, no major thermal areas, no cold spots,
no wet areas and a more efficient and cost-effective
insulated wall panel.

1. Install bottom width mesh and place single girder in


form, tie to mesh or pre-stressed cables.

Contact Customer Service. All


product madetoorder.

127

Sandwich Panel Connectors


P14 Type L Connector Pin DS_P14
and P15 Type M Connector Pin DS_P15

12 ga.
Diameter

The Dayton Superior Connector Pin is used to tie two wythes together. The pins
work in tension and compression to resist wind pressure and suction. The pins also
prevent bowing and separation of the individual wythes of the panel. The pins
are produced from type 304 stainless steel for excellent corrosion resistance. Since
the pins are made from small diameter wire, they are flexible and do not offer any
resistance to movement from thermal stresses that build up in the panel.

Length
Length

The P15 Type M Connector Pin is available in 4-3/4", 5-1/2" and 6-1/4" lengths. The
P14 Type L Connector Pin is available in lengths of 4-3/4", 5-1/2", 6-1/4" or 7-1/2".
P14 Type L
Maximum pin spacing is 4'-0" on center, or one pin for each 5 sq. ft. of panel area.
Connector Pin
However, pins should be spaced at 24" maximum on center along the panel edges.

P15 Type M
Connector Pin

Note: Larger panel sizes may have non-load bearing wythe divided into two or more sections.

To Order:
Specify: (1) quantity, (2) name, (3) length.

Example:
200, P14 Type L Connector Pins, 5-1/2" length.
Connector Pin Selection Chart
Safe Working Load Per Pin (lbs.)

Insulation
Thickness

Tension

1"

300

1,900

1-1/2"

300

800

2"

300

450

2-1/2"

300

300

Compression

Safe Working Load provides a factor of safety of approximately 3 to 1.


Minimum f'c to be 3,000 psi.
Minimum embedment length of open end of pin is 2".
Note: 14 ga. pins are also available on special order.

Preferred Attachment Method


Type L Pin

Maximum Pin Distance From Anchor Center


Insulation Thickness
1"

1-1/4"

1-1/2"

1-3/4"

2"

2-1/2"

5'-0"

7'-0"

8'-6"

10'-0"

12'-0"

17'-0"

Alternate Attachment Method


Type L Pin

Sandwich Panel
Connectors
128

11/12

Sandwich Panel Connectors


P9 Precast Sandwich Panel Tie

DS_P9

The Dayton Superior P9 Precast Sandwich Panel Tie is manufactured


to specifications from 3 gauge (0.243" diameter) stainless steel or
galvanized wire.

1-1/2"

Place the connectors at the edge of the foam insulation so the body of the
tie is at the joint line between two pieces of foam. Next, the ends of the
tie are rotated 90 so they bear against the foam insulation. Spacing of
the panel connectors are per job requirements.

B
(Insulation
Thickness)

P9 Precast Sandwich Panel Tie

After the panel ties have been attached to the foam insulation, they are
placed on the freshly placed bottom wythe of concrete. Later, the top
wythe of concrete is placed.
The chart, below, lists the sizes of panel ties produced in the ast for
various precasters. Other sizes can be produced on special order.
P9 Precast Sandwich Panel Tie

To Order:
Specify: (1) quantity, (2) name, (3) A & B dimensions
(4) finish.

Example:

3"

4"

4"

5"

6"

7"

8"

1"

1"

2"

3"

3"

3"

3"

P37 M Anchor Shear Connector

200, P9 Precast Sandwich Panel Ties, A=4", B=2",


stainless steel.

DS_P37

The Dayton Superior P37 M Anchor Shear Connector is available in various


sizes. Fabricated from 1/4" diameter galvanized wire, these connectors are
designed for use as a shear connector in precast concrete sandwich panels.
For proper use, place the connectors at the following maximum spacing:

18" on center maximum across the width of the panel.

24" on center maximum along the length of the panel.

Place additional connectors around the panels lift points.

A
1/4" Diameter

Edge distance requirements are 6" minimum center line to the panel end and
4" minimum center line to the panels edge. Place connectors parallel to the
length of the panel.

1"

Minimum embedment at the open end is 2"

To Order:

4"

P37 M Anchor Shear Connector

Specify: (1) quantity, (2) name, (3) style.

Example:
1200, P37 M Anchor Shear Connectors, No. CP107.

P37 M Anchor Shear Connectors


A

Maximum
Insulation
Thickness

CP106

2"

6"

2"

CP107

2"

7"

3"

CP206

1-1/2"

6"

2-1/2"

CP207

1-1/2"

7"

3-1/2"

11/12

Insulation

Sandwich Panel
Connectors

Style

Typical Installation

129

Notes and Sketches

130

11/12

Strand Restraining Devices


Prestress Strand Restraining Devices
By deflecting some of the prestressing strands, in a precast prestressed
concrete beam, a more favorable distribution of stresses within the concrete
beam is obtained. When using deflected strands, the eccentricity of the
prestressing force is reduced in the area of decreasing dead load moment. By
reducing the tensile stresses in the concrete, the load that can be applied to the
beam can be increased by an amount equal to the weight of the beam itself.
The benefits obtainable through strand deflection are such that many precast
prestressed concrete plants are designed so that the prestress strands can
be deflected. When using depressed strands, it is necessary that strand
restraining devices be provided at the points within the concrete beam where
the strand deflections occur.
Working closely with many prestressed concrete producers, Dayton Superior
has developed a complete line of strand restraining devices. Since 1958,
Dayton Superior strand deflection devices have been recognized and accepted
as the industry standard. All units are manufactured on a production basis and
are produced with positive (no welding) mechanical connections.
These units maintain a clear distance of 1-1/2" from bottom of the strand
restraining device to beam bottom yet still hold a 2" dimension from the
centerline of the strand to the beam bottom. DS_PrestressStrand

Large variety of styles available to fit your needs

View of Strand Restraining Device


Free-turning rollers contribute
additional safety, reducing frictional
resistance.

Illustration of swivel action as


strand restraining device responds to
strand tensioning.

Miscellaneous
Products

Note: For more information on the complete prestressing system or individual components, request a copy of the
Prestress Strand Deflection Device Handbook

11/12

131

Precast Bracing
T14 Precast Wall Braces

DS_T14

The Dayton Superior T14 Precast Wall Braces are all steel, heavy duty wall braces designed to quickly and easily align and
brace tilt-up wall panels. Rough adjustment of the T14 braces is easily accomplished by telescoping the pipes to the nearest
incremental hole.
Final adjustment is then achieved by simply turning the brace. Dayton Superior wall braces are available in numerous sizes
to provide a continuous range of panel heights of fifty feet or more. Refer to the chart below for additional information.
Wall Plate
Wall
Plate
Ball
Bearing
Coupler

Adjusting
Screw

Specify: (1) quantity,


(2) name, (3) model.

Example:

Telescoping Pipes
Danger! To prevent
accidental removal
of alignment pin,
insert a 10d double
headed nail through
hole in alignment
pin, bending the
protruding portion of
the nail to a 45 degree
minimum angle

To Order:

200, T14 Precast Wall


Braces. Model B8.
Fixed
Length
Pipe

Adjusting
Screw

Foot Plate

T14 Precast Pipe Brace

Foot
Plate

T14 Precast Jumbo Brace

* Note: Field assembly is required for B14 and B15 braces.

T15 Pipe Brace Extensions


The Dayton Superior Pipe Brace Extensions are available for the B8 and B12 pipe brace models.
The T15 extension for the B12 model extends the brace ten feet. Extensions for the B8 brace
are available in five feet and ten feet lengths.
DS_T15

To Order:
Specify: (1) quantity, (2) name, (3) model.
Miscellaneous
Products

Example:
40, T15 Pipe Brace Extension, 5' extension for B8 braces.

132

11/12

Precast Bracing
Brace Loading

DS_BraceLoading

Bracing recommendations are for the sole purpose of temporarily bracing fully erected concrete panels during construction
- against wind loads only. This temporary bracing design is based on The American Society of Civil Engineers (ASCE)
Minimum Design Loads for Building and other Structures, as recommended by the Tilt-up Concrete Associations Guideline
for Temporary Wind Bracing of Tilt-up Concrete Panels During Construction, TCA Guideline 1-05. The ASCE standard and
the TCA guideline allow the basic wind speed, which is based on a 50-year mean recurrence interval, to be multiplied by a
reduction factor for a 5-year mean recurrence interval which determines the construction wind speed used in the design of
bracing systems.
Brace anchors and main, knee, lateral and/or end braces are not designed or intended to sustain impact loads. Precautions
must be taken to arrange the panel erection sequence so as to avoid the potential for impacting upright panels or portions
of the bracing system. Bracing recommendations for other loads or forces that might be applied to the bracing system
are beyond the scope of Dayton Superior. For bracing recommendations other than wind loads, the user should engage a
design agency with capabilities of performing such a service.

Brace Removal
This bracing system is designed to temporarily support panels against wind loads until the building structure is complete
and self supporting. The bracing system should never be disconnected or removed until the panels are secured by the
permanent structural connections and all lateral load resisting systems are in place.
If the structural documents do not indicate when the temporary bracing system can be removed, the engineer of record
should be consulted.

Panel should be plumb with braces and knee braces installed before crane releases panel.

Lateral bracing should be installed immediately upon the crane and crew clearing the braces and before the next
panel is erected.

Lateral bracing must be continuous, connected at each brace, and tied off with end braces at the end of each line.

Panels require a minimum of two braces per panel.

End braces to ground and/or cross braces must be installed every 100 ft. to prevent lateral movement of braces and
to provide total brace stability.

All members of the brace system must be in place and secured at the end of each day.

Knee and lateral bracing must be located at mid-length of pipe brace.

Knee brace must be firmly fixed at bottom end to prevent possible upward buckling of main brace.

Do not erect panels or continue working during excessive windy or adverse weather conditions.

All brace inserts should be a minimum of 12" from any panel edge, opening, control joint or construction joint.

Panel bracing is designed to withstand specified wind loads until panels are connected to the structural system of the
building. Do not remove any members of the bracing system until all structural connections are completed.

Use only the brace type as noted on the Panel Layout Sheet. No substitute brace hardware shall be used and all
braces must be positioned at the specified locations.

For special bracing conditions that require deviation from the bracing dimensions shown on the Panel Layout Sheet
contact Dayton Superior for recommendations.

See Panel Layout Sheet for type of brace, number of braces per panel, as well as knee and lateral bracing requirements.

Welding or bolting the tilt-up panels in place might preclude the use of braces.

After winds of 35 mph or more have been experienced at the job site, the tilt-up contractor must check the tightness
of the bolts that secure the wall and foot plates to the concrete. Re-tightening of these bolts to the proper torque
will assure that the pipe braces are secure.

The safe working load of the panels bracing system may be drastically reduced if other types of brace anchors are
used as part of this projects bracing system, other than specified brace anchors.

Warning! Failure to install knee, lateral and end braces (when required) will greatly reduce the safe working load of the
specified brace and may allow panels to fall causing severe injury or death.

11/12

133

Miscellaneous
Products

Safety Notes:

Precast Bracing
Bracing to Cylindrical Deadman

DS_CylindricalDeadman

Use the chart at the right to select the proper size deadman
if your project requires the use of a deadman for brace
attachment in lieu of an anchor cast into a floor slab.

How to select the proper size deadman:


1. Determine the maximum applied brace load for the project.
2. The proper deadman must weigh at least as much as the
maximum individual brace load.
3. Find a number on the deadman chart that is equal to or
greater than the required deadman weight. Follow the
numbers in the top column and the far left column of the
chart for the proper diameter and height of the deadman.

Weights Of Deadman (Kips)


Height

24"
30"
36"
42"
48"
Diameter Diameter Diameter Diameter Diameter

2'-0"

.94

1.47

2.12

2.89

3.77

2'-6"

1.18

1.84

2.65

3.61

4.71

3'-0"

1.41

2.21

3.18

4.33

5.65

3'-6"

1.65

2.58

3.71

5.05

6.60

4'-0"

1.89

2.95

4.24

5.77

7.54

4'-6"

2.12

3.31

4.77

6.49

8.48

5'-0"

2.36

3.68

5.30

7.22

9.42

Example:

5'-6"

2.59

4.05

5.83

7.94

10.37

Maximum Applied brace load = 3,200 lb.

6'-0"

2.83

4.42

6.36

8.66

11.31

Acceptable deadman sizes are: Diameter Height

6'-6"

3.06

4.79

6.89

9.38

12.25

24" 7'-0"

7'-0"

3.30

5.15

7.42

10.10

13.19

30" 4'-6"

7'-6"

3.54

5.52

7.95

10.82

14.14

36" 3'-6"

8'-0"

3.77

5.89

8.48

11.54

15.08

8'-6"

4.01

6.26

9.01

12.27

16.02

9'-0"

4.24

6.63

9.54

12.99

16.96

9'-6"

4.48

6.99

10.07

13.71

17.91

10'-0"

4.71

7.36

10.60

14.43

18.85

4 #4 Vertical Bars
3 #3 Ties @ 8" o.c.
3/4" Diameter
Cast-in Floor Brace
Anchor or T13
Coil-Anchors 3/4"
Diameter x 4-1/2"
Long

42" 2'-6"

Note: Always hand or auger excavate hole for deadman.


Minimum allowable soil bearing pressure is to be 1,500 psf.
Minimum concrete compressive strength fc shall be = 2,500 psi at use.
1 Kip = 1,000lbs.

6"
Max

Brace Maintenance
During the construction process, braces may be exposed to adverse conditions that could damage or render them unusable.
Braces should be inspected for proper operation, damage and wear after each use.
This inspection is typically performed by a Dayton Superior Certified Precast Dealer when the braces are returned.
However, when braces are transferred from one job to another without being returned to Dayton Superior or its dealer for
maintenance, the user must inspect all braces prior to their being reused.
This inspection should check for missing parts, parts, wear, dings, kinks, straightness, indication of any application of heat
and/or other damage.
Any brace that shows signs of wear, has missing parts, damage, or is questionable should be set aside and not used.

Miscellaneous
Products
134

11/12

Precast Bracing
Accubrace Total Bracing System DS_Accubrace

Accubrace is a total bracing system of Braces and Helical Ground Anchors engineered for unsurpassed speed and efficiency for
tilt-up or pre-cast applications. Installed by Dayton Superior professionals, this system provides an affordable, engineered solution.

Braces
A high-capacity brace designed to allow increased brace spacing for temporary stabilization of concrete wall panels.

Helical Ground Anchors


The Helical Ground Anchor (HGA) is part of a total bracing system designed for rapid installation and the ability to immediately
load the helical ground anchor for unsurpassed speed and efficiency on any tilt-up or pre-cast project.

HGA Extension
Certain sites where the foundation soils are lower strength may require the use of an HGA
Extension. This shaft is the same section (1" square bar) but is 4' in length and has a 10" helical
plate set at 10" from the top of the extension.

Transition
Brace
Connector

Transition Brace Connector


The Transition Brace Connector connects the brace to the HGA. It leads to quicker installation and
better alignment of the brace center-line to the HGA center-line.

Advantages:
Reduces the number of braces needed by up to 60% to provide accelerated construction

Engineered bracing system with documented load capacity

We offer Professional Engineer review and and stamp services

Bracing on the outside of wall avoids structural steel erection

Bracing on the inside of wall without a slab avoids holes in slab and/or vapor barrier

Integrated in-line connection to the brace with the HGA and Transition Brace Connector

Rapid, all-weather installation

Recipient of the 2007 Robert Aiken Innovation Award sponsored by the TCA.

Removable and reusable

Part #

Standard
Brace
Length

Brace
Length
Min.

Brace
Length
Max

A21B

21'

21'-0"

23'-3"

23,200 lb.

15,500 lb

230 lb

A27B

26'

25'-7"

27'-3"

17,250 lb.

11,500 lb

265 lb

A32B

32'

30'-9"

33'-3"

22,500 lb.

15,000 lb

A37B

37'

35'-9"

38'-3"

18,000 lb.

12,000 lb

A42B

42'

40'-9"

43'-3"

16,500 lb.

11,000 lb

695 lb

A52B

52'

50'-9"

53'-3"

16,500 lb.

11,000 lb

1030 lb

Ultimate Load Brace Working


(Pull)
Load (Pw)

* NOTES: Does not include weight of connectors.



Safety Factor is 1.5:1

11/12

HGA

Brace
Weight*

HGA
Extension

Description

SWl
Tension

Length

405 lb

Standard HGA

12,000 lb

7'-2"

460 lb

Standard HGA Extension*

15,000 lb

4'-0"

* NOTE: When an extension is used, the working load


of the HGA increases to 15,000 lb for the installed
torque of 2,200 ft/lb.

135

Miscellaneous
Products

Formliners

When it is time to choose concrete formliners, make your


first choice Dayton Superior. For stock or custom orders,
we have you covered.
Choose from three product lines: Elasto-Tex, Vinyltite
and Thermoform. One will answer your precast
concrete needs.
Easy to install and easy to strip, Dayton Superior
Formliners come in more than 500 contemporary designs
and are available in Single Use, Medium Reuse and High
Reuse. Repeat patterns eliminate seam lines.
Best of all, our formliners are labor saving and money
saving, and they provide esthetics to your precast project.
Note: For more information on formliners, request a copy
of the Formliner Catalog.

Elasto-Tex High Re-Use Elastomeric Formliner

DS_Elastotex

Elasto-Tex formliner is produced from a two-component urethane and is mold-bonded to 1/2" HDO plywood, ready for
mounting to your forms. It is the preferred formliner material when 25 or more pours, or reuses, are required. Elasto-Tex is
available in all existing formliner patterns, as well as custom textures.
Its stiffness and compressive strength hold the desired shape during concrete placement and vibration. Its flexibility
accommodates almost any desired texture or sculpture effect. The built-in resilience and toughness of Elasto-Tex result in
an exceptional capability for precise reproduction of the desired pattern or texture. Elasto-Tex improved wear resistance
provides high reuse factors that could be in excess of 100 times.

Vinyltite Trapezoidal Interlocking Formliners

DS_Vinyltite

For sharp-edged trapezoidal textures, choose Vinyltite formliners. The use of our Vinyltite formliner eliminates the costly
labor involved in wood construction. You get continuous uniform texture reproduction pour after pour. Vinyltite is
impervious to moisture and it wont swell, bulge or distort design integrity.
Vinyltite is easy to use with superior results. Vinyltite pre-drilled nailing strip lets you attach the formliner to the concrete
slab or form without splitting or tearing. No more unsightly nail head impressions, and less sacking and patching costs.
Interlocking joints ensure proper alignment and prevent concrete leakage. Connect the pieces to form large panel sections
with no seam lines.
Wide ranges of widths and lengths. Lightweight, easy to handle and made of rigid HIPS or ABS plastic, Vinyltite comes
in Single Use, Medium Use, or Heavy Reuse materials. Profiles are available in 6 inches to 18 inches wide, extruded to
specified lengths up to 45'-0" for clean installation every time.

Thermoform Vacuum-Formed Formliners

DS_Thermoform

Thermoform Concrete formliners are rigid plastic liners that are used to achieve detailed patterns and textured concrete
surfaces for precast architectural concrete. You may select from a variety of patterns, or custom order to fit your needs
at only a nominal additional cost. All patterns are available in three different ranges: Single Use, Medium Reuse and High
Reuse.
The Single Use, made from styrene, is ideal where the formliner will be used only once. The Medium Reuse, made from ABS
materials, can be used up to 10 times. The High Reuse can be used up to 20 times under most conditions.
The vacuum-forming technology used in this product line allows virtually unlimited texturing opportunities, offering the
most flexibility in custom designed patterns. This low cost reproduction process allows you to add exceptional economic
options to the design integrity of your precast concrete projects. Due to the stretching of the plastic sheet material that
occurs during the reshaping of the thermoforming process, some patterns with a high degree of texture or relief should not
be produced in the thinner, single-use material. Normally supplied in 4' x 10' sheets.

Miscellaneous
Products
136

11/12

Rustication
Rustication Strips
Specify Rustication Strips for concrete surfaces when distinct features or reveals are required.
Each Rustication Strip is a durable, precision molded piece which contains a metal strap core for attachment to concrete
formwork. Rustication Strips are available in a variety of standard shapes to meet almost any project requirement.
Dayton Superior Rustication Strips are manufactured in premium ElastoTex material for extensive reuse.

Advantages:

Sharp, detailed features in finished concrete surfaces.

Standard reusable shapes minimize forming costs.

Enhances the appearance of exposed concrete elements.

P/C Base Ht. Top

30755
3/4" x 3/4" x 1/4"
30756 1" x 3/4" x 1/2"
30757 1-1/2" x 3/4" x 1"
30758 2" x 3/4" x 1-1/2"
30759 1" x 1" x 1/2"
30760
1-1/2"
x 1" x 1"
30761 2" x 1" x 1-1/2"
30762 2-1/2" x 1"
x 1-3/4"
30763 3" x 1" x 2-1/4"
30764 4" x 1" x 3-1/4"
30765 5" x 1" x 4-1/4"
30766 6" x 1" x 5-1/4"
30767 1-1/2" x 1-1/2" x 1"
30768 2" x 1-1/2" x 1-1/2"
30769 3" x 1-1/2" x 2"
30770
2" x 2" x 1"
30771
3" x 2" x 2"
30772
4" x 2" x 3"

Slope
P/C Base Ht.
30776
3/4" x 3.4" x
1-1/16"
1" x 1" x
1-7/16"
30777
30778
1-1/2" x 1-1/2" x 2-1/16"

11/12

Miscellaneous
Products

P/C Base Ht.


Angle
30773
1-5/32"
x 1" x 60
30774
1-1/2"
x 1" x 53
30775
2" x 1" x 45

137

Other Products
Rustications, Chamfers and Coverers
Rustications, chamfers and other products manufactured by Victory Bear provide innovative solutions to the designer and
the contractor. These products provide significant labor savings in the installation of the rustications and chamfers along
with eliminating much of the building finish problems which occur with wood products. And now these products can be
found at a Dayton Superior distribution center near you.

SLAB SAVER

VB_SlabSaver

2' PVC Edge pieces installed in the bottom of wall panels used to protect floors during
panel erection, eliminating damage to the floor slab during panel erection.

RUSTICATION

VB_Rustication

" x 45 degree PVC rustication in widths of 2.25", 2.5", 3.5", 5.5", 8.0" and 11.5". These
have the patented Flex Edge Seal, insuring a tight joint with the concrete slab and
these utilize the Victory Bear Base Clip for easy installation. 1/2" x 60 degree low profile
rustication also available.

SNAP RUSTICATION

VB_SnapRustication

" Triangular PVC rustication which opens to allow easy installation and then snaps shut
to prevent concrete seepage.

BULKHEAD

VB_Bulkhead

" PVC bulkhead chamfer providing chamfer on both sides of the bulkhead. This product
is used with both " plywood and 2x materials. It features both the patented Flex Edge
Seal and utilizes the Base Clip to secure the product to the floor slab.

BULLNOSE VB_Bullnose
PVC Single Bullnose chamfers provide the radius edges when the designer desires a
different effect from the traditional triangular building edges.

RADIUS CORNER VB_RadiusCorner


6" PVC Radius Corner provides a distinct radius at a fraction of the cost.

CHAMFERS

VB_Chamfers

" x 45 degree PVC chamfers in both single and double chamfer versions. This product
utilizes the patented Flex Edge Seal and is attached to the floor slab with adhesives or
traditional nails or screws.

CHAMFERS LOW PROFILE

VB_ChamfersLowProfile

1/2" x 60 degree PVC chamfers in both single and double chamfer versions. This product
utilizes the patented Flex Edge Seal and is attached to the floor slab with adhesives or
traditional nails or screws.

DRIP EDGE CHAMFER

VB_DripEdgeChamfer

" x 45 degree PVC drip edge chamfer for use where doors, windows, dock doors and
archways require both a chamfer and drip edge. This product utilizes the patented Flex
Edge Seal and is attached to the floor slab with adhesives or traditional nails or screws.

RECESSED WINDOW SYSTEM

VB_RecessedWindowSystem

A unique utilization of several of the above products with a recessed window chamfer to
add a classic detail for doors and windows in the concrete wall panels.

JOINT COVER

VB_JointCover

PVC Joint Covers provide the building owner an attractive cover for the joints inside of
the building. Joint Covers will fit into panel joints between " and 1" gaps.

SAW CUT COVER

VB_SawCutCover

Miscellaneous
Products

PVC Saw Cut Cover temporarily seals the floor slab joints with a unique low profile design.

138

11/12

Other Products

P8A Architectural Post Forms

DS_P8A
Dayton Superior P8A Architectural Post Forms are used with precast
concrete panels in the construction of highway sound barriers. Twenty
(20) standard sizes are available. Surface textures can be applied to
the concrete posts with the use of one of the many Dayton Superior
formliner patterns.

P8A Architectural Post Form

P8B Bridge Girder Forms DS_P8B


Dayton Superior Bridge Girder Forms are designed in compliance
with American Association of State Highway and Transportation
Officials (AASHTO) and Precast/Prestressed Concrete Institute (PCI)
specifications to produce quality bridge girders.

Heavy duty for durability.

Free-standing or self-stressing applications.

Available in standard AASHTO, bulb tee and modified


configurations.

Furnished as a total system or for use with existing pallets or


accessories.

P8B Bridge Girder Form

P8M Median Barrier Forms DS_P8M


The creative design and quality construction of the Dayton Superior Median
Barrier Forms provides for increased production. These Median Barrier Forms can
be furnished with conventional or rollover bulkheads.

Standard design for inverted casting.

3/16" skin plate.

May be anchored to slab for conventional casting.

Available in 10'-0" and 12'-0" lengths.

Units can be bolted together for longer product length.

Specials available on request.

Rail span member included for support of customer blockout or insert.

P8P Pile Forms

P8M Median Barrier Form

DS_P8P

Dayton Superior standard pile forms are available for piles in single or
double configurations up to 24" square for free-standing casting.

Also available for self-stressing applications.

Various shapes and configurations are available to meet specific


requirements.

Heavy duty construction and quality workmanship means long form life.

Miscellaneous
Products

P8P Pile Form

11/12

139

Other Products
PLW EZ Lok Wheel

DS_PLW

Made from engineered composite resins, the E-Z Lok Wheel was designed for use in
situations where a lightweight wheel is not sufficient to maintain proper location of the
reinforcement. Once attached, this wheel will stay in place.
The unique symmetrical design maintains a consistent cover, regardless of the rebar size.
With a wider hub, the E-Z Lok Wheel will not rack or fall off. The E-Z Lok Wheel offers
flexibility and strength with multiple hub diameters for rebar sizes from 3/8" (No. 3) to 3/4" (No.
6) and is furnished in a variety of clearances.

PIW EZ Lok Wheel


It is suitable for use with larger diameters of welded wire fabric. The wheel will not change
shape and will always provide uniform concrete cover. The E-Z Lok Wheel is perfect for any vertical application
where concrete cover must be maintained and is the ultimate side form spacer when strength counts.
Note: Concrete cover is defined as the distance from where the reinforcement sits in the hub of the wheel to the outside of the wheel
(where it contacts the form).

To Order:

The E-Z Lok Wheel meets all requirements and qualifies as a CRSI Class 1
Bar Support. Available in the following cover heights: 1-1/2", 2-1/2" and
3". Sold in full cartons only.

Example:

Specify: (1) quantity, (2) name, (3) cover height.


2 cartons, E-Z Lok Wheels, 1-1/2" cover height.

PSW Space Wheel DS_PSW


The Space Wheel is excellent for use in wall, beam and column applications. It is made
from composite resins, allowing the cardboard forming to roll easily over the reinforcement
without damaging the face of the form, while still maintaining proper alignment.
Minimum form contact provides for excellent concrete finish without the rust marks or
blemishes typical to other methods of spacing reinforcement. Designed to fit on a wide
range of bar and wire mesh sizes assuring accurate placement, the Space Wheel is the perfect
light duty side-form spacer.
Note: Concrete cover is defined as the distance from where the reinforcement sits in the hub
of the wheel to the outside of the wheel (where it contacts the form).

PSW Space Wheel

The Space Wheel meets all requirements and qualifies as a CRSI Class 1 Bar Support. Available
in cover heights from 3/8" to 3". Sold in full cartons only.

Miscellaneous
Products
140

11/12

Other Products
Tower Bar Chair

DS_TowerBarChair

Tower Bar Chairs are used to support widely spaced, light steel in slab and deck construction. Each
bar chair provides two cover heights that are clearly marked for field identification. Available in 3/4"
to 2-1/2" cover heights and sold in full cartons only.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

PBC Tower Bar Chair

Example:
2 cartons (900), 121288, Tower Bar Chairs, 1-3/4" to 2" cover.

Tower High Chair DS_TowerHighChair


Tower High Chairs are strong, preassembled supports for heavy applications. The
design features staple-down feet, quick-tie hooks and two service heights. The two
service heights allow reduced inventory and save warehouse space. Tower High
Chairs are well suited for applications where multiple layers of steel are required.
Chairs are available in cover heights from 2-3/4" to 10" and sold in full cartons only.
An optional Sand Plate (sold separately) is available for use on grade.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

Example:

PTC Tower
High Chair

PTSCB Tower Chair


Sand Plate

2 cartons (300), 121295, Tower High Chairs, 6" cover.

E-Z Chair

DS_EZChair

E-Z Chairs are designed for superior strength and stability. They are well suited for
tiltup, precast and poured-in-place slab applications. They are available in 3/4" to
6" cover heights for rebar sizes up to #11. E-Z Chairs are sold in full cartons only.
An Optional Sand Plate is available for use on grade or in sandwich panel
applications.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

PEZ E-Z Chair

PSP Sand Plate

Example:
4 cartons (700), 121271, E-Z Chairs, 4" cover.

Castle Chair

DS_CastleChair

Castle Chairs are uniquely designed with a wide base ring to provide stability on poorly compacted or
expansive soils. Each Castle Chair offers two cover heights to allow for variation in grading. They are
strong enough to carry the weight of ironworkers and concrete finishers, but will not damage moisture
protection membranes. Castle Chairs are available in 1-1/2" to 4-1/4" cover heights and are sold in full
cartons only.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

PCC Castle Chair


Miscellaneous
Products

Example:
2 cartons (700), 122837, Castle Chairs, 2-1/2" to 2-3/4" cover.

11/12

141

Other Products
X-Chair

DS_XChair

X-Chairs are light weight, inexpensive chairs used for supporting rebar and wire mesh in horizontal
applications. The X-Chairs novel design produces a very strong support with minimal surface contact.
X-Chairs are available in 1/2" to 2" cover heights and are sold in full cartons only.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

Example:

PXC X-Chair

1 carton (1100), 122834, X-Chairs, 2" cover.

E-Z LOK Slab Bolster

DS_EZLokSlabBolster

E-Z LOK Slab Bolster provides a strong, stable support and spacer for
rebar in slab or wall applications. The E-Z LOK Slab Bolster can be used in
individual 32" sections or the sections can be snapped together to satisfy
any job-required length. E-Z LOK Slab Bolster is available in 3/4" to 3" cover
heights and is sold in full cartons only.

To Order:
Specify: (1) quantity, (2) name, (3) cover height.

PSB E-Z LOK Slab Bolster

Example:
2 cartons (300), 78066, E-Z LOK Slab Bolster, 2" cover.

PSBU Strongback SBU

DS_PSBUStronbackSBU

Supports top layer in Double Mat application, rebar or wire mesh, slabs,
heavy duty on-grade, corrugated decking, side-form spacer-belowgrade applications only, precast. Cover heights from 1" to 3-1/4" (1/4"
increments)

Designed for use with epoxy-coated/FRP/stainless steel/galvanized


rebar

Intended for use in corrosive environments

Spans corrugations in elevated deck applications

Suitable for use on vapor barriers or insulating foam

To Order:

No overlap required

Specify: (1) quantity, (2) name, (3) name.

Manufactured in 30" lengths in standard boxes

Example:

Special packaging available in 5' or 10' sections, bundled and palletized

20 Boxes, 2-1/2" Cover Panel Pads.

Strong as metal SBU

Panel Pads

PSBU StrongBack SBU

DS_PanelPad

1/2" Thick

Miscellaneous
Products

Panel Pads were created especially for use in the precast industry for stacking.
When placed on top of the precast concrete elements, the Panel Pads will
support the weight of additional elements without damage to either element.
The unique bubble design allows the precast materials to cure uniformly.
Panel Pads are manufactured to snap in half.
The 2-1/2" x 5-1/2" pads are spaced around the
To Order:
precast unit.
Specify: (1) quantity, (2) name.

Example:

5-1/2"

PPP - Panel Pads

200, Panel Pads.

142

11/12

Other Products
Slab Bolster

DS_SlabBolster

Rebar

Dayton Superior Slab Bolster is used to support lower slab steel from
the slab form. Legs are spaced on 5" centers. Available in 3/4" to 3"
heights in 5" lengths and in bright basic, galvanized, plastic protected
or stainless steel protected.
Slab
Bolster

Slab Bolster

Beam Bolster DS_BeamBolster

Beam
Bolster

Rebar

Dayton Superior Beam Bolster is used to support lower beam steel from
the soffit form. Legs are spaced on 2-1/2" centers. Available in 1-1/2"
to 5" heights in 5" lengths. Manufactured in bright basic, galvanized,
plastic protected or stainless steel protected.
Beam Bolster

Continuous
High Chair

Continuous High Chair


Dayton Superior Continuous High Chair provides support for upper
slab steel, eliminating the need for carrier bars. Fabricated in 2" to 15"
heights, in 5" lengths with legs spaced on 7-1/2" centers. Available
in bright basic, plastic protected, galvanized and stainless steel
protected. DS_ContinuousHighChair

Rebar

Continuous High Chair

Individual High Chair

Rebar

Dayton Superior Individual High Chair is used to support upper


steel directly or by means or a carrier bar. Available in bright
basic, plastic protected, galvanized and stainless steel protected.
DS_IndividualHighChair

High
Chair

Individual High Chairs

Bar Chair DS_BarChair

Rebar

Dayton Superior Bar Chair is used to support widely spaced light steel in
slab construction. Available in 3/4" to 2" heights in bright basic, plastic
Bar Chair
protected, galvanized and stainless steel protected.

Joist Chair DS_JoistChair


Dayton Superior Joist Chair is used to support two bottom bars in the
ribs of joist or grid type slabs. Available in 4", 5" and 6" overall widths;
1/4", 1" and 1-1/2" heights; and in bright basic, plastic protected,
galvanized and stainless steel protected.

Bar
Chair

Rebar

Joist Chair

Miscellaneous
Products

Joist Chair

11/12

143

Other Products
K50 Void Retention Insert DS_
K50VoidRetentionInsert
The Dayton Superior K50 Void Retention Inserts primary function is to
conveniently position and firmly hold in place void tubes used in precast slabs,
piles, box beams, etc. Use of the K50 inserts eliminates the possibility of the
voids floating to the surface when concrete is placed in the forms. The K50
insert is injection-molded from nonreactive, noncorrosive thermoplastic and is
designed to fit 10"- and 12"-diameter voids.

K50 Void
Retention Insert
3"

2"

2-3/4"

9-1/4"

To Order:
Specify: (1) quantity, (2) name.

Example:
200, K50 Void Retention Inserts.

H13 Round Void Hold Down

DS_H13RoundVoidHoldDown

The Dayton Superior Round Void Hold Down is a one piece unit that completely encompasses the
round void tube and is attached to your form using a standard 3/4" coil bolt. This prevents movement
in any direction of the void tube. Maintained in stock for 10" and 12" OD Diameter Void Tubes, other
sizes available.

To Order:
Specify: (1) quantity, (2) dia of tube (4) plain or galvanized finsih.

Example:
200, H13 12" Round Hold Down, Plain.

Miscellaneous
Products
144

11/12

Other Products
P80 Shim Strips

DS_P80ShimStrips

Dayton Superior P80 Shim Strips assure accurate placing and leveling of tilt-up panels and other architectural and structural
components because they:

are made in convenient thicknesses, lengths and widths allowing precise leveling and alignment.

permit field changes in load bearing requirements with stock on hand.

are less expensive and safer than steel. They have extreme stability and eliminate rust-stained concrete and spalling.

are size scored for convenience of application. Prevent waste material can be readily picked up and stored in the
open for future use.

will not fracture under load.

are available from stock in thicknesses of 1/16", 1/8" and 1/4" and lengths of 3" and 4". The widths of 3" x 24" are
scored every 3" and the widths of 4" x 24" are scored every 2". This allows for easy snap off as needed. Additional sizes
available on request.

are impervious to liquids, ground chemicals, alkalis and microorganisms. The continuing performance characteristics
are stable and predictable.

will not rust, rot or leach when exposed to wet surfaces and have no odor.

arrive at the job site in precise thicknesses and lengths.

eliminate the need for saws, hand tools or cutters. A definite saving in time, labor and money is realized. The strips
are easily applied and lie flat.

decrease damage potential to the adjacent concrete components. Point projection of aggregate is absorbed without
fracture or effect on the load-bearing characteristics.

Engineering Data: The pertinent physical properties of Dayton Superior plastic shims are presented as follows:

Compressive strength of 8,000 to 9,000 psi with no fracture, even at


26,000 psi.

Classed as slow-burning with no toxic fumes.

Negligible cold flow characteristics; i.e., less than 1% at 1,000 psi and
73F. for 10,000 hours.

Coefficient of linear expansion is 3 to 5 x 10-5 inches/inch/C

P81 Shimpak

To Order:
Specify: (1) quantity, (2) name, (3) length.

Example:
300, P80 Shim Strips, 1/4" x 4".

DS_P81Shimpak

Dayton Superior shimming material is an engineered multipolymer plastic


specifically formulated for use by the construction industry.

Precast Element

This material provides an optimum combination of physical properties for


a shim in applications where high compressive strength and load bearing
are important. It facilitates the placement of tilt-up structural, and other
architectural, members.

P81 Shimpaks

These pre-assembled packages of heavy duty shims are designed for


large precast units.

Shimpaks are very advantageous in precise placing and leveling of


large panels.

Their use eliminates time consuming correction of elastomeric drift


and makes alignment safer and easier.

Popular sizes are 4" x 6" and 4" x 4" packs which are 1-1/16" thick. Shimpaks
are made up of shims in the following thickness sequence: one 1/16", three To Order:
1/4" and two 1/8". Tilt-up panels can be levelled within 1/16" by removing or Specify: (1) quantity, (2) name, (3) size.
adding one or more elements.

Shimpaks are held together with a resilient band for easy removal or
addition of elements.

Alternate sizes available on request.

11/12

Foundation or other
structural member.

Example:

Miscellaneous
Products

200 packs, P81 Shimpaks, 4" x 6".

145

Other Products
P82 Bearing Strips

DS_P82Bearing Strips

Designed for use with prestressed concrete plank between


the plank and any surface, such as poured or precast
concrete, steel or masonry.

Absorb projecting aggregate stress preventing plank or sill


damage without effect on the load bearing characteristics.

Allow faster erection because of easier positioning.

Nonslip surface ensures positive placement.

Permit thermal motion and point rotation without an


elastomeric layer.

P82 Bearing Strips

Available in full cartons only. Each carton holds 300 2" x 48" strips.

Test data available on request.

Thicknesses of 1/8" and 1/4" in stock. Lengths of 48" in stock. Widths of 24", scored at 2" intervals for easy snap off and
flexibility in use. Alternate sizes or scorings available on request.

P83 Horseshoe Spacers


No staining, no rust, no corrosion, even with aluminum.

Less expensive than steelno plating required.

Lightweight and preciseeasy to handle and transport.

Cut to size or prescored for easy on-site snap-off.

Width

Available with holes, other slot sizes or different width, length


or thickness on special order. Minimum order 100 pcs. of each
thickness and size.

Thickness

Length

To Order:

Slot Size

Specify: (1) quantity, (2) name, (3) size.

P83 Horseshoe Spacer

Example:
2 cartons, P82 Bearing Strips, 1/4" x 48".
P83 Horseshoe Spacer Selection Chart
Width

Length

2"

3"

1/16", 1/8" or 1/4"

Thickness

13/16" x 2-7/16"

3"

4"

1/16", 1/8" or 1/4"

13/16" x 2-15/16"

P84 Korolath Core Plugs

Slot Size

DS_P84KorolathCorePlugs

Core plugs designed for manufacturers of prestressed hollow core plugs

Lightweight, easy-to-insert, block off grout flow

Exclusive wall taper design of plastic plugs assures tight fit

Plug numbers refer to the diameter of the core holes, not the thickness of the plank
Number

Diameter

Plugs/Carton

Specify: (1) quantity, (2) name, (3) size.

400

4"

1,000

Example:

600

6"

2,000

800

8"

1,000

To Order:

2 cartons, P84 Core Plugs, No. 600.


Miscellaneous
Products

P84 Korolath Plugs

146

11/12

Other Products
F67, F68, and F69 Ceiling Hangers
F67 Ceiling Hanger

DS_F67F68F69CeilingHangers

3/8"

The Dayton Superior F67 Ceiling Hanger


is designed for Flexicore deck slabs. Two
sizes of ceiling hangers accommodate
all five of the deck slabs. The 13" ceiling
hanger fits the 10" and 12" deck slabs.
The F67 hanger is placed between the
slabs before keyways are grouted and
topping placed.

4"

The Dayton Superior F69 Ceiling Hanger is


normally used between hollow core slab
members to support suspended ceilings or
utilities. Standard lengths are 6" and 10".
Other lengths are available on request.

3/8"
diameter

9"
or 13"

The Dayton Superior F68 Ceiling Hanger


is commonly used with double tees. The
hanger is placed between the tees and
used to hang ceilings, utilities, etc. The
wide T of the hanger provides a large
bearing area. 6" length is standard; other
lengths are available on request.

1"

2"

3/4"

F68 Ceiling Hanger

F69 Ceiling Hanger

2"

5/8"

3/8"
diameter

6"
/2"

1-1

3/8"
diameter
"

7/8

"

7/8

"

7/8

1"

1"

F68

F67
Flexicore Deck

2"
Topping

6"
or 10"

2"
Topping

F69

Precast Double Tees

2"
Topping

Hollow Core
Slab

F69

F68

F67

1"

Ceiling hangers can be placed where required but are commonly spaced at 2 ft. intervals throughout the beam or slab
length to provide for future hanger requirements. All hangers are made from galvanized stock.
Gauge

Type

Safe Working Load with


Keyway Grouted
and 2" Topping

Type

Safe Working Load with


2" Topping

16

F67

200 lbs.

F68, F69

400 lbs.

Specify: (1) quantity, (2) name,


(3) gauge, (4) length.

12

F67

400 lbs.

F68, F69

600 lbs.

Example:

Note: Hangers must have minimum of 2" topping slab in place and properly cured to adequately develop
safe working load. With properly applied topping, approximate safety factor is 3 to 1.

F75 Marble Facing Anchor

To Order:

1200 pcs., F68 Ceiling Hangers, 12


gauge, 6" long, P80 Shim Strips,
1/4" x 4".

DS_F75MarbleFacingAnchor

The Dayton Superior F75 Marble Facing Anchor is a special stainless steel anchor
used for anchoring marble, slate, thin limestone, etc., to precast work. The hooks
are placed into predrilled holes in the marble and poured in with the concrete. Other
sizes are available on special order.

To Order:

4"
2-1/2"

8 Gauge
Stainless Steel
Wire Type 430
or 304

Miscellaneous
Products

Specify: (1) quantity, (2) name.

2-3/4"

11/12

147

Other Products
Cushion-Lock Reglet Type B4

PVC Construction

No Reaction with Concrete

No Caulking now or ever

100% Leakproof

No Exposed Metal Nails

10 ft. Lengths

DS_CushionLock

The advanced design of this reglet offers a number of exclusive features, yet the
in-place cost is actually lower than that of conventional reglets. The completely
enclosed design of the B4 Reglet prevents any concrete from entering during
pouring operation. Just prior to the installation of the counter-flashing, the
integral protective strip is pulled off, exposing a clean recess ready to receive the
counterflashing and no caulking is needed as the snap-in and lock-in patented
features of this reglet provides a 100% leakproof joint, yet future removal of the
counterflashing for inspection or repair of roofing material is possible.

This Strip is pulled


off just prior to
installation of
counterflashing.
Easily removed.

Made of PVC (polyvinyl chloride)


Plastic /060" thick, highest quality,
ASTM-D1784-81 Class 14333D.

Recommended gauges for counterflashing are .020" to .032" maximum for aluminum or zinc; 26 to 24 gauge for steel; 16
or 20 oz. for copper. Fast and easy installation of counterflashing can be made under all weather conditions.
Each order for type B4 Reglet is supplied with sufficient connector plugs and installation instructions with a full-size
template pattern for counterflashing.

Specifications
Specify Dayton Superior Type B4 Reglets and counterflashing in sheet metal section of specs. Sample specification: Use
Cushion-Lock Type B4 Reglet of PVC (polyvinyl chloride) plastic ASTM-D1784-81, Class 14333D, as manufactured by Dayton
Superior Corporation.

Connector Plugs

DS_ConnectorPlugs

Connector Plugs, made from flexible PVC 3" long are supplied with B4 Reglet.
They serve both to connect lengths of Reglet together, with adjoining openings
perfectly aligned, as well as a plug to keep concrete from entering reglet at ends.
Plugs may be easily removed to installation of counterflashing.

Installation
Counterflashing snaps and locks in position. Fastener is concealed and protected
by counterflashing. DO NOT rivet or fasten ends of counterflashing
together.
A. Reglet is fastened to form at 12" O.C. with 6 or 8 penny doubleheaded nail.
B. Concave design provides spring-like action to hold reglet tightly
against form lumber, when nail is driven home.
C. Reglet in position, after form is stripped, but prior to removal or
integral protective strip.
D. Lip acts as waterstop to prevent any possible water seepage
behind reglet.

Miscellaneous
Products
148

11/12

Other Products
Insulation Fixings

DS_InsulationFixings

Insulation Fixings are specifically designed for attaching foam insulation plates or foam panels in insulated
wall applications. They are primarily used in marine dock construction. With its button head, wire mesh
stays firmly in place over the foam panel. Available in 1" to 4" heights, 1,250 per carton.

To Order:
Specify: (1) quantity, (2) name, (3) height.

Example:
2 cartons, insulation fixing, 4" height.
PFA Insulation
Fixings

T68 ACA 1000 Construction Spray Adhesive

DS_T68ACA1000

T68 ACA 1000 is a specially designed, high strength, fast-tack contact spray adhesive to bond:

Concrete

Wood

Metal

MDF

Plastic

High Density Foam

Precast applications include:


General Purpose

Reveal/Rustication Strips

Chamfer

Blockouts

Etc.

T68 ACA 1000


Construction Spray
Adhesive
Sold only by the case:
12 cans per case.
One case minimum order.

Shipped ground freight only no air freight


Cal Voc Complaint Product available Rialto, CA only T68ACA1000C
Coverage Rate/Can
250 275 Sq. Ft.

To Order:
Specify: (1) quantity, (2) name.

Example:

Miscellaneous
Products

3 cases, T68 ACA 1000 Construction Spray Adhesive.

11/12

149

Magnets
P153 Magnetic Steel Chamfer and Reveal DS_P153
Dayton Superior offers a variety of shapes of P153 Magnetic Steel Chamfers and Reveals. All offer unlimited reuses. The
magnets are embedded in the steel and sealed with an epoxy material to insure no damage form concrete or maximum reuse.
Chamfers are typically 1/2" x 1/2", 3/4" x 3/4", and 1" x 1". Reveals can be made to fit most requirements. Many of these
products are available in rigid plastic that offers a lower expense to the precaster but a smaller reuse factor. A flexible
3/4"x3/4" rubber chamfer is available when radius precast shapes are encountered.

P154 On/Off Magnets, Cam Magnets, Button, Loaf Magnets and Accessories

DS_P154

Dayton Superior has a wide variety of magnets for use in precast forms.

ON/OFF MAGNETS



Strong adhersion and shear capacity 650# to 2500# adhersion


Easy to turn on or off using 5/8" wretch with 90, 1/4 turn of end rotor
Magnet attraction only on bottom of magnet
Accepts standard op adapters or custom adapters provided by
Dayton Superior

Custom On/Off Magnet

CAM MAGNETS



Magnet is always on but easy to release from steel using built in cam release arm
Magnet attraction along sides and bottom
Available in different styles: Flat, Floating, Hole-Former, Notch
Strong adhesion and shear capacity for small magnet, up to 1000# adhesion

Cam Magnet

BUTTON MAGNETS



1 Ton and 2.5 Ton Adhesion Capacities standard other sizes available
Easy push down button engages magnet & easy release from steel,
using butt and release tool
Attachment to forms brackets available
Release tool available to reduce labor

Custom Setting Plug

LOAF MAGNETS



Standard sizes 3", 5", and 11" custom sizes available


Magnet is always on but can be released from steel using separate release arm
Used in many applications including inside steel rails and securing wood forms in place
Attachments to forms brackets available

MANHOLE STEP MAGNET AND RADIUS





Lift Insert Recess Member

Size available for flat walls for 12", 16" & 24" steps
Step pins available for all step manufacturer's products
Separate tool used to remove step pin assembly from concrete
Eliminates the need to drill holes in core for step pins

HOLE FORMERS AND DUCK MAGNETS




Sizes available to fit into any size block-out, hole former or mandrel
Different magnetic holding strengths available
Eliminates the need to drill opening in concrete after it has been cast

BOOT GASKETS



Loaf Magnet

Utilizes magnet with Cam Release Arm


Special fabricated attachment mechanisms available
Available for any size boot gasket
Available in hinged model for 90 degree attachment

Miscellaneous
Products

PVC PIPE ATTACHMENT MAGNET



150

Pipe Holding Magnets Light Duty Urethane


Pipe Holding Magnets Heavy Duty - Steel

11/12

Index
7.5 T Disposable Void Former.................. 78
ACA 1000............................................ 149
Accubrace Total Bracing System.......... 135
B1............................................................. 81
B2............................................................. 81
B11........................................................... 82
B12........................................................... 82
B13........................................................... 82
B14........................................................... 83
B16........................................................... 84
B17........................................................... 84
B18........................................................... 85
B25........................................................... 82
B33........................................................... 86
Bar Chair................................................. 143
BarLock Coupler.................................... 114
Beam Bolster.......................................... 143
Bearing Strips......................................... 146
Braces..................................................... 135
Bridge Girder Forms............................... 139
Cap Plug................................................. 101
Castle Chair......................................... 141
Ceiling Hangers...................................... 147
Chamfers................................................ 138
Coil Bolt.................................................... 83
Coil Nut.................................................... 82
Coil Rod.................................................... 82
Coil Ties Used as Inserts........................... 81
Connecting Systems Nylon Threaded
Inserts................................................. 109
Connector Plugs..................................... 148
Construction Spray Adhesive................. 149
Continuous High Chair.......................... 143
Corewall Edge and Corner Details......... 120
Corewall Nut Type Slotted Insert........... 116
Corewall Nut Type Slotted Insert......... 117
Corewall Slotted Insert II...................... 119
Corewall Slotted Strap Anchor............ 118
Corewall Strap Anchor......................... 118
Corewall Strap Type Slotted Insert......... 116
Corewall Strap Type Slotted Insert...... 118
Corewall Threaded Strap Anchor........ 118
Countersunk Screw.................................. 37
Cushion-Lock Reglet............................ 148
D108A.................................................... 110
D410....................................................... 111
D487....................................................... 112
D490....................................................... 111
D491....................................................... 112
D492....................................................... 112
D493....................................................... 112
Delta Tie................................................. 123
Disposable Setting Plugs.......................... 75
Double Flared Coil Loop Insert..........84, 86
Double Flared Loop Insert....................... 86
Double Swivel Lifting Plate...................... 96
Double Tee Anchor................................... 78
Dowel Bar Splicer................................... 113
Ductile Embed Insert.............................. 103
Dur-O-Web........................................... 121
Edge Lifting Plate..................................... 97
Elastomeric............................................. 136
Elasto-Tex................................................ 136
End Pickup Inserts..............................92, 94
Expanded Coil Ferrule Inserts................. 104

11/12

Expanded Coil Inserts............................... 89


Eye Bolt.................................................... 87
Eye Nut..................................................... 87
E-Z Chair............................................... 141
E-Z LOK Slab Bolster............................ 142
EZ Lok Wheel...................................... 140
F5 .............................................................. 99
F11.......................................................... 115
F12.......................................................... 115
F42............................................................ 99
F43.......................................................... 100
F44.......................................................... 101
F45.......................................................... 101
F47............................................................ 86
F48............................................................ 87
F49............................................................ 87
F49A......................................................... 87
F50.......................................................... 102
F52.......................................................... 102
F53............................................................ 88
F54.......................................................... 103
F56............................................................ 89
F57.......................................................... 104
F58............................................................ 89
F59.......................................................... 104
F60............................................................ 89
F61.......................................................... 104
F62.......................................................... 105
F63............................................................ 90
F64.......................................................... 106
F67.......................................................... 147
F68.......................................................... 147
F69.......................................................... 147
F72.......................................................... 107
F74.......................................................... 107
F75.......................................................... 147
Ferrule Loop Insert................................. 106
Flared Thin Slab Coil Insert...................... 90
Flared Thin Slab Ferrule Insert................ 105
Flat Washer.............................................. 82
Fleet-Lift Cable Bail Ring Clutch............... 41
Fleet-Lift Cast Steel Recess Plug............... 64
Fleet-Lift Disposable Recess Plug............. 66
Fleet-Lift Erection Anchor........................ 42
Fleet-Lift Erection Anchor with 45 Head
with Shear Plate................................... 55
Fleet-Lift Erection Anchor with Shear
Plate....................................................44
Fleet-Lift Erection Anchor with Shear Plate
and Shear Pin....................................... 46
Fleet-Lift Flat Foot Anchor....................... 58
Fleet Lift Forged Erection Anchor............ 48
Fleet Lift Forged Erection Anchor with
Sheer Plate............................................ 49
Fleet-Lift Forged Two-Hole Anchor.......... 60
Fleet-Lift H-Anchor 2-Ton......................... 57
Fleet-Lift Holding Plate............................. 62
Fleet-Lift Holding Rod.............................. 62
Fleet-Lift L-Anchor.................................... 56
Fleet-Lift Magnetic Plate.......................... 71
Fleet-Lift Plate Anchor.............................. 59
Fleet-Lift Reusable Recess Plug................ 62
Fleet-Lift Ring Clutch................................ 40
Fleet-Lift S-Anchor 6-Ton.......................... 58

Fleet-Lift Sandwich Panel Erection


Anchor............................................. 53
Fleet-Lift Sandwich Panel Erection Anchor
with Shear Plate................................... 53
Fleet-LIft Sandwich Panel Reinforcing
Bars.................................................. 54
Fleet-Lift Shear Bar................................... 61
Fleet-Lift T-Anchor.................................... 56
Fleet-Lift Tension Bar................................ 61
Fleet-Lift................................................ 39
Fleet-Lift TwoHole Anchor...................... 59
Fleet-Lift Two-Hole Erection Anchor........ 51
Fleet-Lift Two-Hole Erection Anchor with
Shear Plate........................................... 51
Fleet Patch................................................ 70
Forged Erection Anchor with Shear Plate
and Secondary Shear Pin..................... 50
Formliners............................................... 136
H13......................................................... 144
Hanger Hook.......................................... 115
Hanger Insert......................................... 115
Headed Dowel Bar Insert....................... 110
Heavy Coil Nut......................................... 82
Helical Ground Anchors......................... 135
Hex Nut for Shelf Angle Inserts............. 115
HGA........................................................ 135
HGA Extension....................................... 135
Horseshoe Spacers................................. 146
Individual High Chair............................. 143
Insert Locator Plugs................................. 96
Insulation Fixings................................... 149
Joist Chair............................................... 143
K50......................................................... 144
Korolath Core Plugs............................... 146
L Connector Pin...................................... 128
Lifting Angle............................................. 93
Loop Ferrule Insert................................... 99
Magnetic OnePiece Swift Lift Recess..... 38
Magnetic Steel Chamfer and Reveal..... 150
Magnets................................................. 150
M Anchor Shear Connector............... 129
Marble Facing Anchor........................... 147
M Connector Pin.................................... 128
Median Barrier Forms............................ 139
Mounting Washers.................................. 81
Nylon Threaded Inserts.......................... 109
One Piece Magnetic Utility Anchor
Recess.................................................76
P8A......................................................... 139
P8B......................................................... 139
P8M........................................................ 139
P8P......................................................... 139
P9........................................................... 129
P12D....................................................... 121
P12G....................................................... 127
P14......................................................... 128
P15......................................................... 128
P21........................................................... 88
P24......................................................... 123
P25........................................................... 93
P30.................................................116, 117
P31.................................................116, 118
P32......................................................... 118
P33......................................................... 118
P34......................................................... 118

Index
P37......................................................... 129
P38......................................................... 119
P49........................................................... 82
P50........................................................... 17
P51........................................................... 19
P52.....................................................22, 25
P52W........................................................ 25
P53........................................................... 32
P54........................................................... 34
P56.....................................................23, 35
P56PL..................................................23, 36
P56R......................................................... 35
P57........................................................... 36
P58........................................................... 36
P59........................................................... 26
P60........................................................... 33
P61........................................................... 37
P62........................................................... 37
P63........................................................... 37
P63PL........................................................ 37
P64........................................................... 37
P64PL........................................................ 37
P66........................................................... 38
P66PL........................................................ 38
P67PL........................................................ 38
P68PL........................................................ 38
P69........................................................... 38
P75........................................................... 74
P75C......................................................... 74
P75H......................................................... 74
P76.....................................................75, 78
P76C......................................................... 75
P76D...................................................75, 78
P76M........................................................ 76
P77........................................................... 78
P80......................................................... 145
P81......................................................... 145
P82......................................................... 146
P83......................................................... 146
P84......................................................... 146
P87......................................................... 108
P88......................................................... 108
P90......................................................... 109
P91NC...................................................... 41
P91S......................................................... 40
P92.....................................................42, 54
P92AH...................................................... 55
P92DP....................................................... 46
P92FE........................................................ 48
P92FEW.................................................... 49
P92FEWDP................................................ 50
P92H......................................................... 51
P92HP....................................................... 51
P92P......................................................... 44
P92S......................................................... 53
P92SP....................................................... 53
P93........................................................... 56
P94H......................................................... 57
P94S......................................................... 58
P95F.......................................................... 58
P95P......................................................... 59
P96........................................................... 59
P96F.......................................................... 60
P98S......................................................... 61
P98T......................................................... 61

P99........................................................... 62
P99C......................................................... 64
P99D......................................................... 66
P99P......................................................... 70
P100...................................................62, 76
P100M...................................................... 71
P100MS.................................................... 71
P101...................................................62, 76
P104...................................................38, 76
P110......................................................... 79
P153....................................................... 150
P154....................................................... 150
Panel Pads.............................................. 142
Pile Forms............................................... 139
Pipe Brace Extensions............................ 132
Plain Ferrule............................................ 100
Plastic Setting Bolt................................... 93
PLW........................................................ 140
Post Forms.............................................. 139
Precast Sandwich Panel Tie.................... 129
Precast Wall Braces................................ 132
Prestress Strand Restraining Devices..... 131
PSBU....................................................... 142
PSW........................................................ 140
Recess Plugs............................................. 23
Rocket/Kohler Ferrule Insert................. 102
Round Cut Washer for Shelf Angle
Inserts............................................. 115
Round Void Hold Down......................... 144
Rustications............................................ 138
Rustication Strips................................... 137
Safety......................................................... 1
Setting Screw........................................... 71
Shimming Washers for Shelf Angle
Inserts...............................................115
Shimpak................................................. 145
Shim Strips............................................. 145
Single Flared Coil Loop Insert.................. 85
Single Pickup Insert.................................. 91
Slab Bolster....................................142, 143
Sleeve-Lock " SCH40 PVC.................. 112
Sleeve-Lock Form Plug......................... 112
Sleeve-Lock Grout................................ 111
Sleeve-Lock Grout Sleeve..................... 111
Sleeve-Lock Port Plug........................... 112
Sleeve-Lock Seal Plug........................... 112
Space Wheel....................................... 140
Star Adapter Plug................................... 108
Star Holzin Insert.................................. 108
Straight Coil Loop Insert.......................... 84
Strongback SBU.................................. 142
Superior Lift System................................. 60
Swift Lift................................................. 17
Swift Lift Anchor..............................22, 25
Swift Lift Anchors for Edge Lifting.......... 25
Swift Lift Eye Anchor............................. 32
Swift Lift Lifting Eye............................... 19
Swift Lift Magnetic Setting Plate........... 38
Swift Lift Narrow Recess Plug................ 35
Swift Lift Plus Holding Plate................... 38
Swift Lift Plus Holding Stud................... 37
Swift Lift Plus Recess Plug...................... 36
Swift Lift Plus Stud Plate........................ 38
Swift Lift Plus Threaded Plate................ 38
Swift Lift Plus Wing Nut........................... 37

Swift Lift Round Recess Plug................. 35


Swift Lift Rubber Ring............................ 36
Swift Lift Setting Plate........................... 37
Swift Lift Shear Bar................................ 26
Swift Lift Smooth Wire Shear Bar.......... 26
Swift Lift Steel Recess Plug.................... 36
Swift Lift Stud........................................ 37
Swift Lift Tapped Plate........................... 38
Swift Lift Tension Bar............................. 33
Swift Lift Throw-Away Recess Plug....... 34
Swift Lift Universal Lifting Eye............... 17
Swift Lift Wing Nut.................................. 37
Swivel Lifting Plate................................... 96
T1.............................................................. 91
T3.............................................................. 92
T3A........................................................... 92
T7S............................................................ 93
T7ST.......................................................... 93
T8.............................................................. 93
T10........................................................... 94
T11........................................................... 94
T12........................................................... 96
T14......................................................... 132
T15......................................................... 132
T21........................................................... 96
T26........................................................... 96
T27........................................................... 97
T68......................................................... 149
T110......................................................... 60
Thermoform........................................ 136
Thin Slab Coil Insert................................. 88
Thin Slab Ferrule Insert..................101, 102
Threaded Insert........................................ 99
Threaded Plastic Plug............................. 107
Threaded Setting Plug........................... 107
Tower Bar Chair...................................... 141
Tower High Chair.................................... 141
Transition Brace Connector.................... 135
Utility Anchor......................................... 74
Utility Anchor and Double Tee Anchor
Setting Plug.......................................... 78
Utility Anchor Cover/Patch....................... 75
Utility Anchor Holding Plate.................. 76
Utility Anchor Holding Rod.................... 76
Utility Anchor Magnetic Setting Plate....76
Utility Anchor Setting Plugs................... 75
Utility Anchor System.............................. 73
Utility Anchor with Clip......................... 74
Vinyltite............................................... 136
Void Retention Insert............................. 144
Welded Wire Girders.............................. 127
Wire Rope Lifting System..................... 79
Wire Rope Loop....................................... 88
X-Chair.................................................... 142

11/12

Notes and Sketches

11/12

Notes and Sketches

11/12

Safety Information

Improper Use of Concrete Accessories Can Cause


Severe Injury or Death
Read, understand and follow the information and instructions in this publication before
using any of the Dayton Superior concrete accessories displayed herein. When in
doubt about the proper use or installation of any Dayton Superior concrete accessory,
immediately contact the nearest Dayton Superior Service Center or Technical Service
Department for clarification. See back cover for your nearest location.

Dayton Superior products are intended for use by trained, qualified and experienced workers only. Misuse or lack of supervision and/or inspection
can contribute to serious accidents or deaths. Any application other than those shown in this publication should be carefully tested before use.
The user of Dayton Superior products must evaluate the product application, determine the safe working load and control all field conditions to prevent applications of loads in excess of a products safe working load. Safety factors shown in this publication are approximate
minimum values. The data used to develop safe working loads for products displayed in this publication are a combination of actual
testing and/or other industry sources. Recommended safe working loads given for the products in this publication must never be exceeded.

Worn Working Parts

For safety, concrete accessories must be properly used and maintained. Concrete accessories shown in this publication may be subject
to wear, overloading, corrosion, deformation, intentional alteration and other factors that may affect the devices performance. All
reusable accessories must be inspected regularly by the user to determine if they may be used at the rated safe working load or should
be removed from service. The frequency of inspections depends upon factors such as (but not limited to) the amount of use, period of
service and environment. It is the responsibility of the user to schedule accessory hardware inspections for wear and remove the hardware from service when wear is noted.

Shop or Field Modification

Welding can compromise a products safe working load value and cause hazardous situations. Knowledge of materials, heat treating and welding
procedures is necessary for proper welding. Consult a local welding supply dealer for assistance in determining required welding procedures.
Since Dayton Superior cannot control workmanship or conditions in which modifications are done, Dayton Superior cannot be responsible for any
product altered in the field.

Interchangeability
Many concrete accessory products that Dayton Superior manufactures are designed as part of a system. Dayton Superior strongly discourages efforts to interchange products supplied by other manufacturers with components supplied by Dayton Superior. When used
properly, and in accordance with published instructions, Dayton Superior products have proven to be among the best designed and
safest in the industry. Used improperly or with incompatible components supplied by other manufacturers, Dayton Superior products or
systems may be rendered unsafe.

Installation

WARNING
1. Dayton Superior Corporatin products shall be installed and used only as indicated on the Dayton Superior Corporation installation
guidelines and training materials.
2. Dayton Superior Corporation products must never be used for a purpose other than the purpose for which they were designed or in a
manner that exceeds specific load ratings.
3. All instructions are to be completely followed to ensure proper and safe installation and performance
4. Any improper misuse, misapplication, installation, or other failure to follow Dayton Superior Corporations instruction may cause product malfunction, property damage, srious bodily injury and death.
THE CUSTOMER IS RESPONSIBLE FOR THE FOLLOWING:
1. Conformance to all governing codes
2. Use of appropriate industry standard hardware
3. The integrity of structures to which the products are attached, including their capability to safely accept the loads imposed, as evaluated by a qualified engineer.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment

Design Changes
Dayton Superior reserves the right to change product designs, rated loads and product dimensions at any time without prior notice.
Note: See Safety Notes and Safety Factor Information.

Dayton Superior Brands


Concrete Accessories
Accubrace
Aztec
Bar Lock
Corewall
Fleet-Lift
Swift Lift
Taper-Lock

Construction Chemicals

Forming Products

Unitex

Symons
Max-A-Form
Steel-Ply
Sym-Ply

Dayton Superior Products


BRIDGE DECK FORMING

Adjustable Joist Hangers


Bridge Overhang Brackets
Haunch and Fillet Forming
Pres-Steel, Coil Rod and Con-Beam
Hangers
Screed Supports

Chemicals

Bond Breakers
Cleaners / Strippers
Concrete Repair/Restoration
Curing Compounds / Sealers
Epoxies
Floor Levelers
Form Release Agents
Grout
Hardeners / Industrial Toppings
Liquid Densifiers
Surface Retarders

FORMING and SHORING


Aluminum Shoring
Ganged Formwork
Garage Beam System
Handset Formwork
Highway Forms
Jump Forms
Modular Deck Shoring
One Sided Frames
Self Spanning Forms
Steel Frame Shoring

FORMLINERS

REBAR SPLICING

ABS Plastic
Polystyrene Plastic
Precision Cut Foam
Solid Urethane
Urethane-Skinned Foam

Forged Dowel Bar Couplers


Grouted Couplers
Lockshear Bolt Couplers
Shear Resistance Products
Straight Thread Couplers
Taper Thread Couplers

PAVING

REBAR SUPPORTS

Dowel Bar Expansion Caps


Dowel Bar Retrofit System
Elastomeric and Hot Pour Joint Seal
Metal Keyway Form Systems
Tie Bar Assemblies
Transverse Bar Assemblies
Welded Dowel Assemblies
Wire Baskets without Dowels

Concrete Dobies
Continuous Plastic and Steel
Bar Supports
Individual Plastic and Steel
Bar Supports
Mesh Chairs
Paving Chairs
Side Form Spacers

PRECAST

TIES AND ACCESSORIES

Anchors and Lift Systems


Coil / Ferrule Inserts
Core Plugs
Magnets
Precast Forms
Rustications/Chamfers
Sandwich Panel Connector
Shear Connectors
Slotted Inserts

Modular Form Ties


Single Waler System
Ties and Accessories

TILT-UP

Braces and Brace Anchors


Helical Ground Anchors
Setting Plugs
Strongback System
Tilt-Up Anchors and Lifting Systems

Contact Information
Corporate Headquarters
1125 Byers Road
Miamisburg, OH 45342
937-866-0711

Accessories and Chemicals

Customer Service: 888-977-9600


Technical Assistance: 877-266-7732
info@daytonsuperior.com

Forming Products

Customer Service: 800-800-7966


Technical Assistance: 877-266-7732
info@daytonsuperior.com

With products proudly made in America and a wide breadth of recognized brands, Dayton Superior is
the most comprehensive, single-source provider for all your concrete construction needs.
DS5
12/12
$9.95

W W W . D A Y T O N S U P E R I O R . C O M

B U I L D I N G

Copyright 2012 Dayton Superior Corporation, All Rights Reserved