Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PCXF14 (2014-05) Low Res

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

PCXF14

Chilled Water

PRODUCT SYSTEM
Wall Mounted
Ceiling Cassette
Ceiling Convertible
Ducted

Fan Coil Unit


Product Catalogue

Products manufactured in an ISO certied facility.


This document contains the most current product information as of this printing.
@2014-05

Wall Mounted Type

Comfortble Air Flow & Lower Sound Level

User given more choice on preferable fan speed, quiet


mode or automatic setting. With the introduction of SCR
indoor fan motor, a step-less change of fan speed results
in smooth air flow and unnoticeable sound level change
during fan speed change.

Easy Maintenance

Air intake grill is easily detachable to be cleaned with

Sleep function for Cool and Heat mode


Once activated, set temperature will be increased /
decreased gradually according to normal sleeping
temperature patterns to ensure a comfortable sleeping
environment.

FWW-L

Wireless Remote Controller


BRC52A

Wired Remote Controller


BRC51A (Option)

Ho

ur

Temperature

Sleep Set
On
0 1/2
1

-1C
at

ing

He

-2C

ng

li
Coo

Heating mode*

Stylish Flat-Panel

Ideal blend of style and function.


The front panel is designed for contemporary style
without compromising on function.
Air intake area is designed to ensure smooth air flow
profile for better sound quality and optimized volume.

Indoor Quiet Mode

More quiet room environment.


With up to five selectable fan speeds, users are given
more choices. By selecting Quiet mode, the sound
pressure level is reduced down to an unobstrusive 24
dBA.
To quickly cool down the room, Turbo model can be
selected for maximum cooling power and highest

+0.5C

+1C

+0.5C

0
Slee 1/2
p Se
t On 1
2

Cooling mode

NIM-Able
Sleep Function For Cool And Heat Mode
Auto Restart With Last-State-Memory
Valve & Valveless Control Options
Self Diagnosis Features
Compact & Easy To Use Wireless Remote Controller

Ho
ur

Comfortable Air Flow & Lower Sound Level


Stylish Flat-Panel
Indoor Quiet Mode
Turbo Mode
Uniform Air Distribution
Easy Maintenance

Temperature

-3C

Auto Restart with Last-State-Memory

In case of sudden power failure during operation, unit


restarts automatically & unit will operate based on
previous setting when power is resumed.
Power Failure
Operation

Power Returns
Stop

Restart

24dBA Is So Quiet You Can Even Hear Whispers

20
Rustling
Of Leaves

30
Pendulum Of
A Wall Clock
24dBA
for
FWWM-L

SL

Fan
Speed

E2 PROM
40
Library

50
Normal Oce

(dB)

Setting stored before power failure.

Turbo

High

Low

Turbo Mode

TURBO function is available in COOL and HEAT modes


only. Once it is activated, the air-conditioner will run into
full power with indoor fan running at MAX speed for 20
minutes. This enables the set temperature to be achieved
faster. If TURBO and SLEEP are activated at the same time,
the SLEEP mode timer will be reset, it will resume after

Compact & Easy To Use Wireless Remote


Controller
Compact and user friendly wireless remote controller
BRC52A offers:
Real Time Clock
"Glow in the dark" ON/OFF Button
Low, Medium, High fan speed options
ON Timer Setting

T room

Wireless Remote Controller


BRC52A

T set
Start

20min

30min

Uniform Air Distribution

Wired Remote Controller


BRC51A (Option)

Automated air swing ensures conditioned air distributed


evenly.

Self Diagnosis Features

This feature helps to detect any faults or malfuctioning in


the system and provide user a warning by blinking of the
LED lights.

Ceiling Cassette Compact Type (600x600)

Specication for Wall Mounted Type ~ 50HZ


MODEL
NOMINAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY

FWW02L

FWW03L

FWW04L

FWW05L

FWW06L

Btu/h

8300

9200

11300

15500

18000

2430

2700

3310

4540

5280

Btu/h

6300

6900

9000

11700

14000

1850

2020

2640

3430

4100

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50C)

Btu/h

11000

12000

15000

20500

25000

3220

3520

4400

6010

7330

NOMINAL TOTAL INPUT POWER

31

32

42

57

72

NOMINAL RUNNING CURRENT

0.20

0.20

0.21

0.30

0.34

220-240 / 1 / 50

V/Ph/Hz

POWER SOURCE
REFRIGERANT TYPE
CONTROL

N/A
AIR DISCHARGE
OPERATION

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL


CFM

HIGH
AIR FLOW

260

280

370

510

620

MEDIUM

CFM

230

250

320

450

520

LOW

CFM

200

220

260

390

460

QUIET

CFM

180

190

240

360

440

USGPM

1.85

2.03

2.51

3.43

4.01

litres/min

7.00

7.68

9.50

13.00

15.18

NOMINAL WATER FLOW RATE


HEAD LOSS (COOLING)

kPa

34.0

24.0

31.0

30.0

36.0

HEAD LOSS (HEATING) : 50C

kPa

29.0

20.0

25.0

27.0

33.0

MAX. WORKING PRESSURE

kPa
m/s

0.68

0.74

0.97

0.83

1.01

SOUND PRESSURE LEVEL (H/M/L/Q)

dBA

34 / 29 / 25 / 24

35 / 30 / 25 / 24

42 / 39 / 32 / 29

42 / 38 / 34 / 32

46 / 42 / 39 / 37

UNIT DIMENSION

HXWXD

mm

288 X 800 X 206

310 X 1065 X 224

PACKING DIMENSION

HXWXD

mm

344 x 874 x 274

386 X 1136 X 314

kg

CONDENSATE DRAIN SIZE

mm

PIPE CONNECTION

mm

INDOOR UNIT

14

DIRECT

FAN SPEED

HIGH

RPM

1030

1050

1310

1035

1250

MEDIUM

RPM

890

910

1150

920

1070

LOW

RPM

760

780

955

825

970

TYPE

SINGLE PHASE SCR

INDEX OF PROTECTION (IP)

IP20

INSULATION GRADE
RATED
INPUT POWER
FAN MOTOR
RATED
RUNNING
CURRENT

IP44
E

HIGH

31

32

42

57

72

MEDIUM

29

31

37

50

68

LOW

25

29

33

43

60

HIGH

0.20

0.20

0.21

0.30

0.34

MEDIUM

0.19

0.20

0.20

0.29

0.32

LOW

0.17

0.19

0.19

0.26

0.31

STARTING CURRENT

0.40

0.40

0.40

0.30

0.43

MOTOR OUTPUT

18

18

18

26

30

0.29

0.29

0.95

0.95

POLES

4
COPPER

MATERIAL
DIAMETER

7.00

mm

MATERIAL

ALUMINIUM

FACE AREA

0.18

0.18

ROW

FILTER

0.18
2

WATER VOLUME
AIR QUALITY

Branch Duct Connection


Sleep Function For Cool & Heat Mode
Auto Restart With Last-State-Memory
NIM-Able
Self Diagnosis Features
Choices Of Wired Or Withless Remote Controller

12.70

DRIVE

FIN

Compact Design
Fresh Air Intake
Stylish & Slim Panel
Built In High Head Drain Oump & Water Flow Switch
4 Way Air Discharge & Air Swing
Valve Or Valveless Control Options

CROSS FLOW FAN

FAN

COIL

FWF-C

19.05

TYPE

TUBE

Wired Remote Controller


BRC51A

1608

SURFACE AIR VELOCITY

UNIT WEIGHT

litre

0.52

0.58

TYPE

0.58
WASHABLE SARANET FILTER

QUANTITY

CASING

Wireless Remote Controller


BRC52A

AUTOMATIC LOUVER (UP & DOWN)

pc

COLOUR

WHITE

MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

Compact Design

Ceiling Cassette C Series body dimension is only 570 mm x


570 mm which can easily fits into a 600 mm ceiling grid.

Branch Duct Connection

Specication for Ceiling Cassette Compact Type ~ 50Hz

Improves air flow distribution when there is an


obstruction. It allows for air conditioning of two rooms
simultaneously.
Branch duct chamber

NOMINAL COOLING CAPACITY

Discharge duct

600mm

Room 1

570mm

570mm

NOMINAL SENSIBLE COOLING CAPACITY

Wall

600mm

Room 2

Sleep Function For Cool And Heat Mode


Once activated, set temperature will be increased /
decreased gradually according to normal sleeping
temperature patterns to ensure a comfortable sleeping
environment.

Ho
ur
-3C

3520

4690

5280

NOMINAL TOTAL INPUT POWER

63

64

79

NOMINAL RUNNING CURRENT

0.28

0.28

0.35

The slim panel can be blended easily into decoration and


interior design.

Built In High Head Drain Pump & Water Flow


Switch

CONTROL

The unit comes with a 700 mm built-in high head drain


pump. A safety float is incorporated int he drain pump to
monitor its water level.

Power Returns
Stop

OPERATION
CFM

380

400

440

MEDIUM

CFM

290

310

330

LOW

CFM

230

220

280

USGPM

2.03

3.43

3.57

7.68

12.98

13.51

HEAD LOSS (COOLING)

kPa

19.3

26.9

28.8

HEAD LOSS (HEATING) : 50C

kPa

16.8

23.9

26.5

MAX. WORKING PRESSURE

kPa
m/s

0.75

0.76

0.83

SOUND PRESSURE LEVEL (H/M/L)

dBA

42 / 35 / 29

45 / 38 / 30

48 / 40 / 36

UNIT DIMENSION - ( ) WITH PANEL

HXWXD

mm

PACKING DIMENSION - ( ) PANEL

HXWXD

mm

It comes with 4 way air discharge and air swing function to


ensure better air distribution and circulation in the room.

mm

PIPE CONNECTION

mm

HIGH

RPM

725

810

900

MEDIUM

RPM

565

630

700

LOW

RPM

460

480

610

INDUCTION

INDEX OF PROTECTION (IP)

IP20
B

INSULATION GRADE

FAN MOTOR
RATED
RUNNING
CURRENT

HIGH

63

64

79

MEDIUM

51

58

73

LOW

46

52

69

HIGH

0.28

0.28

0.35

MEDIUM

0.23

0.25

0.32

0.21

0.24

0.31

STARTING CURRENT

LOW

0.32

0.30

0.47

MOTOR OUTPUT

17

23

28

POLES
TUBE

6
MATERIAL

COPPER
mm

DIAMETER

7.00
ALUMINIUM

MATERIAL
FIN

FACE AREA
ROW

litre

WATER VOLUME
FILTER

0.24

0.25

0.43

0.83

0.83

0.25

WASHABLE SARANET FILTER

TYPE
QUANTITY

CASING

Wireless Remote Controller Wired Remote Controller


BRC52A
BRC51A

19.05

TYPE

COIL

17 + 3

DIRECT

FAN SPEED

Choices Of Wired Or Wireless Remote


Controller

17 + 3
19.05

DRIVE

AIR QUALITY

The design is flexible enough to allow for either valve or


valveless control installation.

316 X 630 X 630 (126 X 700 X 726)


15 + 3

TURBO FAN

FAN

Setting stored before power failure.

Valve Or Valveless Control Options

250 X 570 X 570 (295 X 640 X 640)

TYPE

RATED
INPUT POWER

Compact and user friendly wireless BRC52A and wired


BRC51A remote controller offer :
Real Time Clock
"Glow in the dark" ON/OFF Button
Low, Medium, High fan speed options
ON Timer Setting

kg

CONDENSATE DRAIN SIZE

4 Way Air Discharge & Air Swing

1608

SURFACE AIR VELOCITY

Restart

E PROM
700mm

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

HIGH

litres/min

Auto Restart With Last-State-Memory

Operation

4 WAY AUTOMATIC LOUVER (UP & DOWN)

UNIT WEIGHT (UNIT + PANEL)

This feature helps to detect any faults or malfuctioning in


the system and provide user a warning by blinking of the
LED lights.

Power Failure

N/A
AIR DISCHARGE

NOMINAL WATER FLOW RATE

In case of sudden power failure during operation, unit restarts


automatically & unit will operate based on previous setting
when power is resumed.

220-240 / 1 / 50

REFRIGERANT TYPE

INDOOR UNIT

Stylish & Slim Panel

V/Ph/Hz

POWER SOURCE

Self Diagnosis Features


Intake duct (Field supplied and installed)

11500
3370

Cooling mode

Heating mode*

10000

18000

+1C

Duct flange (With insulation material)

6500

2930

0
Slee 1/2
p Se
t On 1

-2C

4540

Btu/h

16000

urs

at

He

4100

1910

ng

-1C
ing

2490

12000

li
Coo

+0.5C

15500

W
W

AIR FLOW

+0.5C

FWF05C

14000

Btu/h

Sleep Set
On
1/2
1

FWF04C

8500

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50C)

Ho

Temperature

Knock out hole is available at the unit.


Installation & accessories need to be field supplied &
installed.
Keep the introduction of fresh air intake within 20% of
the total air flow. Also provide a chamber and use a
booster fan.

Temperature

Fresh Air Intake

FWF02C
Btu/h

MODEL

MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

pc

COLOUR

LIGHT GREY

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

Ceiling Cassette Type (900x900)

Multi Comfort - 3 Air Swing Pattern Control

To increase the comfort level of the air conditioned area of


FWK-E series, the system had been built in with three
different type of air flow pattern to suit different
requirement.
* The default setting is pattern 1. The air swing pattern can
be selected via wireless remonote control.

Optimum Air Discharge

Combining 4 ways air discharge and large discharge area


on each side, Ceiling Cassette promote even air
distribution. The additional feature of automatic air swing
helps to distribute the conditioned air more evenly to
every corner of the room.

Standard Setting

Louver is set to swing at the maximum angle for gentle drafts.

Wireless Remote Controller


BRC52A

Wired Remote Controller


BRC51A
10

10

FWK-E

65

Multi Comfort - 3 Air Swing Pattern Control


Fresh Air Intake
Optimum Air Discharge
Superior Sound Level
Branch Duct Connection
Low Height Design
Built In High Head Drain Pump & Water Flow Switch
Modern & Elegant Panel

Low water Pressure Drop


Self Diagnosis Features
NIM-Able
Valve Or Valveless Control Options
Sleep Function For Cool & Heat Mode
Auto Restart With Last-State-Memory
Choices Of Wired Or Wireless Remote Controller

Pattern 1

65

Superior Sound Level

Draft Prevention Setting

With the aid of Coanda eect, direct draft which may lead to
discomfort can be avoided.

With the adapted technology from Daikin turbo fan,


Ceiling Cassette series is able to achieve exceptional low
noise.
With up to 4 selected fan speeds, users are given more
choices. By selecting the Quiet mode, the sound
pressure level can be as low as 23dBA.

Longitudinal vortices
generated along serration
edges accelerate mixing
turbulence which reduces
vortex shedding noise.

10

10
40

Pattern 2

40

Soil Prevention Setting

Even distribution of cooling whilst ensuring ceiling to be


kept spotless.

30

Branch Duct Connection

Improves air flow distribution when there is an


obstruction. It allows for air conditioning of two rooms
simultaneously.

30

Pattern 3

Branch duct chamber


Discharge duct

65

Wall

65

Fresh Air Intake

Knock out hole is available at the unit.


Installation & accessories need to be field supplied &
installed.
Keep the introduction of fresh air intake within 20% of
the total air flow. Also provide a chamber and use a
booster fan.
Duct ange (With insulation material)

Room 1

Room 2

Low Height Design

Unit height as low as 265mm for installation convenience.

265mm 350mm

Intake duct (Field supplied and installed)

Built In High Head Drain Pump &


Water Flow Switch

The unit comes with a 700mm built-in high head drain


pump. A safety float is incorporated int he drain pump
to monitor its water level.

Sleep Function For Cool And Heat Mode


Once activated, set temperature will be increased /
decreased gradually according to normal sleeping
temperature patterns to ensure a comfortable sleeping
environment.
Sleep Set
On
1/2
1

s
ur
-1C
ing

FWK06E

FWK08E

FWK09E

FWK11E

FWK13E

Btu/h

21000

25000

30000

38000

43000

6150

7330

8790

11140

12600

Btu/h

16700

19200

22300

27400

31000

4890

5630

6540

8030

9090

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50C)

Btu/h

28000

33600

38300

45500

52000

8210

9850

11230

13340

15240

NOMINAL TOTAL INPUT POWER

95

126

167

186

227

NOMINAL RUNNING CURRENT

0.44

0.55

0.74

0.85

1.03

NOMINAL COOLING CAPACITY


NOMINAL SENSIBLE COOLING CAPACITY

CONTROL
-3C

AIR FLOW
ling

Coo

N/A
AIR DISCHARGE

4 WAY AUTOMATIC LOUVER (UP & DOWN)

OPERATION

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

HIGH

CFM

750

860

890

1000

1140

MEDIUM

CFM

620

700

720

840

1000

LOW

CFM

480

540

570

680

840

QUIET

CFM

320

380

420

540

700

USGPM

4.71

5.59

6.69

8.45

9.60

litres/min

17.83

21.17

25.29

31.94

36.29

HEAD LOSS (COOLING)

kPa

20

37

22

44

53

HEAD LOSS (HEATING) : 50C

kPa

19

33

19

38

47

MAX. WORKING PRESSURE

kPa

NOMINAL WATER FLOW RATE


+1C

+0.5C

+0.5C

Cooling mode

Ho
urs

0
Slee 1/2
p Se
t On 1

Auto Restart With Last-State-Memory

m/s

0.91

1.04

1.14

1.03

1.17

SOUND PRESSURE LEVEL (H/M/L/Q)

dBA

42/38/32/23

46/42/35/27

48/43/38/30

50/47/43/33

52/49/45/39

UNIT DIMENSION - ( ) WITH PANEL

HXWXD

mm

265 X 820 X 820 (340 X 990 X 990)

300 X 820 X 820 (375 X 990 X 990)

PACKING DIMENSION - ( ) PANEL

HXWXD

mm

341 X 916 X 916 (125 X 1020 X 1020)

376 X 916 X 916 (125 X 1020 X 1020)

Power Failure

Power Returns
Stop

Restart

kg

CONDENSATE DRAIN SIZE

mm

PIPE CONNECTION

mm

26 + 4

26 + 4

DIRECT

FAN SPEED

HIGH

RPM

530

600

660

710

800

MEDIUM

RPM

450

500

550

610

710

LOW

RPM

360

400

450

510

610

INDUCTION

TYPE

IP20

INDEX OF PROTECTION (IP)

INSULATION GRADE
HIGH

95

126

167

186

227

MEDIUM

79

103

109

151

176

LOW

67

89

86

118

144

HIGH

0.44

0.55

0.74

0.85

1.03

MEDIUM

0.40

0.45

0.49

0.71

0.82

LOW

0.36

0.39

0.39

0.57

0.69

STARTING CURRENT

0.44

0.71

0.89

1.02

1.28

MOTOR OUTPUT

30

45

65

80

110

0.46

RATED
INPUT POWER
FAN MOTOR
RATED
RUNNING
CURRENT

Setting stored before power failure.

Low Water Pressure Drop

Also commonly known as low head loss actually helps to


increase the system eciency.

Self Diagnosis Features

This feature helps to detect any faults or malfuctioning in


the system and provide user a warning by blinking of the
LED lights.

Valve Or Valveless Control Options

Choices Of Wired Or Wireless Remote


Controller

Compact and user friendly wireless BRC52A and wired


BRC51A
remote controller offer :
Real Time Clock
"Glow in the dark" ON/OFF Button
Low, Medium, High fan speed options
ON Timer Setting

The design is flexible enough to allow for either valve or


valveless control installation.

10

TUBE

8
MATERIAL

Wireless Remote Controller Wired Remote Controller


BRC52A
BRC51A

COPPER

DIAMETER

mm

FIN

ALUMINIUM
m

FACE AREA
ROW

WATER VOLUME
AIR QUALITY

7.00

MATERIAL

FILTER

litre

0.39

0.39

0.37

0.46

1.36

1.34

1.97

2.35

2.35

TYPE

WASHABLE SARANET FILTER

QUANTITY

CASING

NIM-Able

Able to communicate with the versatile NIM networking


control module and offers the oppurtunity of one
centralized control for a system of multiple indoor units in

POLES

COIL

32 + 4

19.05

DRIVE

32 + 4

TURBO FAN

FAN

E PROM

28 + 4
19.05

TYPE

INDOOR UNIT

In case of sudden power failure during operation, unit restarts


automatically & unit will operate based on previous setting
when power is resumed.

1600

SURFACE AIR VELOCITY

UNIT WEIGHT (UNIT + PANEL)

Operation

220-240 / 1 / 50

V/Ph/Hz

POWER SOURCE
REFRIGERANT TYPE

Heating mode*

Temperature

It is designed with unique "round" side contour and new


LED light location. The rotateable intake grill promotes
uniform installation as well.

MODEL

-2C

at

He

Modern & Elegant Panel

Ho

700mm

Temperature

Specication for Ceiling Cassette Type ~ 50Hz

pc

COLOUR

LIGHT GREY

MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

11

Energy Saving

Compared to the traditional AC motor, DC motor offers the


advantages of lower power input , higher efficiency and
hence more energy saving.

Wireless Remote Controller


BRC52A

Wired Remote Controller


BRC51A

Brushless DC motor has less internal resistance and


better heat dissipation in the stator coils. As a result, it
has higher operating efficiencies since heat can more
efficiently dissipate via the stationary motor housing.
With the green building and development being so
welcomed now, this Ceiling Casstte type with Brushless
DC motor gives you another excellent option to
consider.
Power Consumption Comparison Between
AC Motor & DC Motor

FWKE-E

Branch Duct Connection


Low Height Design
Built In High Head Drain Pump & Water Flow Switch
Superior Sound Level
Fresh Air Intake
Low Water Pressure Drop
Sleep Function For Cool And Heat Mode
Choices Of Wired Or Withless Remote Controller

150

50
600

Low Maintenance & No Brush Sparking

Brushless DC motor does not use carbon brushes or a


mechanical commutator, thus, it is low maintenance and
non-sparking.

4 Pipe System Available*

4 pipe system allows a distribution system that contains


both hot water supply with return lines and a chilled
water supply with return lines.

Modulating Fan Speed Control

100

Due to no brushes or a mechanical


commutator, it has less shaft friction or
inertia and hence less audible noise as
low as 16 dBA.

* FWKE-EH model

200
Power Input (W)

Comfortable
Energy Saving
Low Noise
Low Maintenance & No Brush Sparking
4 Pipe System Available*
Modulating Fan Speed Control
Optimum Air Discharge
Multi Comfort - 3 Air Swing Pattern Control

Low Noise

650

700

750

800

850

900

950

1000

1050

1100

Air Flow (CFM)


AC Motor

Fan speed modulates steplessly based on room


temperature to reduce the difference between room
temperature and set temperature and hence provides
maximum comfort and reduces energy consumption.
* Available in auto fan mode

DC Brushless Motor

Energy Saving Maximum

67%

Recommended Applications

Ceiling Cassette type fan coil with Brushless DC motor


provides a green and pleasant environment.

Room Temperature v.s. CFM

Room Temperature

Ceiling Cassette Type (900x900) With Brushless DC Motor

CFM

Oce
Home

12

Restaurant

13

Specication for Ceiling Cassette Type ~ 50HZ (4 Pipe System)

Specication for Ceiling Cassette Type ~ 50Hz (2 Pipe System)


FWKE05E

MODEL

QUIET

NOMINAL COOLING CAPACITY


NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL HEATING CAPACITY
(ENTERING WATER TEMP. = 50C)
FAN INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE

LOW

MEDIUM

FWKE08E
HIGH

QUIET

LOW

LOW

MEDIUM

HIGH

8200

11900

15900

20100

15200

19800

24700

30000

21000

26800

33100

40100

2400

3500

4650

5900

4550

5800

7250

8800

6150

7850

9700

11750

Btu/h

5800

8700

11700

15400

11000

14500

18500

21900

14600

18900

23800

28600

1710

2540

3440

4510

3220

4260

5410

6430

4270

5540

6970

8370

Btu/h

11300

15200

19800

24200

18400

23900

30400

38200

24100

31600

39100

46700

3300

4450

5800

7100

5400

7000

8900

11200

7050

9250

11450

13700

12

19

37

17

26

50

90

23

39

83

120

0.11

0.13

0.19

0.26

0.19

0.28

0.43

0.74

0.21

0.35

0.55

0.95

220-240 / 1 / 50

NOMINAL SENSIBLE COOLING CAPACITY


NOMINAL HEATING CAPACITY

CFM

220

350

470

620

420

560

890

510

680

870

1060

USGPM

1.84

2.68

3.56

4.52

3.41

4.44

5.55

6.74

4.71

6.01

7.43

9.00

Litres/min

6.96

10.15

13.48

17.10

12.90

16.81

21.02

25.51

17.83

22.76

28.12

34.06

kPa

10

15

24

14

20

15

22

30

41

HEAD LOSS (HEATING) : 50C

kPa

13

21

12

18

12

20

26

37

MAX. WORKING PRESSURE

kPa

NOMINAL WATER FLOW RATE


HEAD LOSS (COOLING)

m/s

0.27

0.42

0.60

0.64

0.43

0.55

0.68

0.81

0.45

0.57

0.71

0.83

SOUND PRESSURE LEVEL

dBA

16

23

31

37

31

37

42

47

34

41

46

51

5200

6500

7750

9000

13300

16700

20700

24500

1560

2240

2990

3850

2910

3810

4850

5750

3890

4900

6060

7170

Btu/h

12800

17200

21700

26100

21800

27300

32800

38200

31900

39100

46200

53400
15650

3750

5050

6350

7650

6400

8000

9600

11200

9350

11450

13550

12

19

37

17

26

50

90

23

39

83

120

NOMINAL RUNNING CURRENT

0.11

0.13

0.19

0.26

0.19

0.28

0.43

0.74

0.21

0.35

0.55

0.95

680

870

1060

POWER SOURCE

N/A
4 WAY AUTOMATIC LOUVER (UP & DOWN)

AIR DISCHARGE
OPERATION

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

AIR FLOW

CFM

EXTERNAL STATIC PRESSURE (H/M/L)


NOMINAL WATER FLOW RATE (COOLING)
NOMINAL WATER FLOW RATE (HEATING)

0.11

IP20

STARTING CURRENT

1.5

2.2

2.2

MOTOR OUTPUT

70

70

100

0.13

0.19

0.26

0.19

MATERIAL
DIAMETER

mm

FACE AREA

WATER VOLUME
FILTER

2.14

2.76

3.37

2.99

3.83

4.67

5.51

3.98

4.98

5.93

6.89

8.12

10.44

12.75

11.31

14.49

17.68

20.87

15.07

18.84

22.47

26.09

USGPM

1.44

1.93

2.43

2.93

2.45

3.06

3.68

4.29

3.58

4.38

5.19

5.99

Litres/min

5.44

9.20

9.20

11.09

9.28

13.91

13.91

16.23

13.55

16.60

19.64

22.68

13

18

10

15

19

12

19

24

32

10

17

22

13

18

25

32

21

30

39

52

MAX. WORKING PRESSURE

kPa

CASING

0.74

0.21

0.35

Litre

m/s

0.27

0.42

0.60

0.64

0.43

0.55

0.68

0.81

0.45

0.57

0.71

0.83

SOUND PRESSURE LEVEL

dBA

16

23

31

37

31

37

42

47

34

41

46

51

0.55

0.95

INDOOR UNIT

FAN
MOTOR

0.46

1.36

1.97

2.35

COIL

CASING

LEAVING WATER TEMPERATURE

12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

DIRECT
RPM

200

280

360

450

350

440

550

660

400

510

INSULATION GRADE
0.11

IP20

IP20

IP20

RATED RUNNING CURRENT

STARTING CURRENT

1.5

2.2

2.2

MOTOR OUTPUT

70

70

100

0.13

0.19

0.26

0.19

FILTER

750

DIAMETER
FACE AREA

0.43

0.74

0.21

0.35

0.55

0.95

7.00

mm

ALUMINUM
m
Litre

0.39

0.37

1.36

1.97

2.35

0.46

WASHABLE SARANET FILTER

TYPE
QUANTITY

0.28

COPPER

MATERIAL
MATERIAL

FIN

630

BLDC

WATER VOLUME

LIGHY GREY

7C

19.05

ROW

COLOUR

32 + 4

TURBO FAN

DRIVE

TUBE

AIR
QUALITY

ENTERING WATER TEMPERATURE

376 X 916 X 916 (125 X 1020 X 1020)

28 + 4
19.05

POLES

COOLING
27C DB / 19C WB

341 X 916 X 916 (125 X 1020 X 1020)

TYPE
FAN

pc

MODE
ENTERING AIR TEMPERATURE

300 X 820 X 820 (375 X 990 X 990)

26 + 4

kg

INDEX OF PROTECTION (IP)

0.37

NOTE:
A) BASED ON EUROVENT CONDITIONS
B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:
FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
FWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT

265 X 820 X 820 (340 X 990 X 990)

TYPE

0.39

WASHABLE SARANET FILTER

1608

SURFACE AIR VELOCITY

ALUMINUM

TYPE
QUANTITY

0.43

510

kPa

7.00

MATERIAL
FIN

0.28

890

kPa

COPPER

ROW

AIR
QUALITY

IP20

POLES

COIL

IP20

720
N/A

HEAD LOSS (HEATING) : 70C

FAN SPEED

RATED RUNNING CURRENT

TUBE

750

560

HEAD LOSS (COOLING)

BLDC

INSULATION GRADE
FAN
MOTOR

630

420

5.80

mm

510

620

1.53

PIPE CONNECTION

400

470

USGPM

19.05

660

350

Litres/min

mm

DIRECT

220

Pa

CONDENSATE DRAIN SIZE

TURBO FAN

INDEX OF PROTECTION (IP)

220-240 / 1 / 50

V/Ph/Hz

mm

TYPE

30700

7200

UNIT WEIGHT

550

26400

19600

19.05

440

22200

6100

HXWXD

350

17700

16600

PACKING DIMENSION - ( ) PANEL

450

24600

5000

32 + 4

28 + 4

360

20800

13000

mm

280

17100

3900

HXWXD

200

13300
9900

UNIT DIMENSION - ( ) WITH PANEL

RPM

15000
4400

376 X 916 X 916 (125 X 1020 X 1020)

FAN SPEED

12300

13100

341 X 916 X 916 (125 X 1020 X 1020)

DRIVE

HIGH

9600

3600

mm

FAN

MEDIUM

6800

10200

HXWXD

mm

LOW

2800

PACKING DIMENSION - ( ) PANEL

TYPE

QUIET

7600

300 X 820 X 820 (375 X 990 X 990)

PIPE CONNECTION

HIGH

2000

265 X 820 X 820 (340 X 990 X 990)

mm

MEDIUM

5300

mm

CONDENSATE DRAIN SIZE

LOW

HXWXD

26 + 4

QUIET

Btu/h

UNIT DIMENSION - ( ) WITH PANEL

kg

HIGH

1608

SURFACE AIR VELOCITY

UNIT WEIGHT

MEDIUM

N/A

Pa

LOW

(ENTERING WATER TEMP. = 70C)

CONTROL

720

FWKE11EH

FWKE08EH

QUIET

FAN INPUT POWER

LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

OPERATION

Btu/h

NOMINAL COOLING CAPACITY

4 WAY AUTOMATIC LOUVER (UP & DOWN)

AIR DISCHARGE

FWKE05EH

MODEL

REFRIGERANT TYPE

N/A

EXTERNAL STATIC PRESSURE (H/M/L)

INDOOR UNIT

QUIET

V/Ph/Hz

AIR FLOW

14

FWKE11E
HIGH

Btu/h

REFRIGERANT TYPE
CONTROL

MEDIUM

pc

COLOUR

LIGHY GREY

NOTE:
A) BASED ON EUROVENT CONDITIONS
B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:
FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
FWKE08/11EH MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

15

Ceiling Convertible Type

Compact Design

Unit height as low as 212mm for instalaltion at limited


ceiling space.
1090mm

Ceiling and Floor Installating Option

The unit is uniquely designed with possiblity to be


installed under or sitting on the floor to suit any interior
design requirements.

630mm

212mm

FWE-E

Wireless Remote Controller


BRC52A

Wired Remote Controller


BRC51A

Far Air Throw


Compact Design
Far Air Throw
Auto Air Swing
Service & Maintenance At Ease
Ceiling & Floor Installing Option
Versatile Installation
Room Temperature Sensing

Saranet Filter
Sleep Function For Cool And Heat Mode
Auto Restart With Last-State-Memory
Valve Or Valveless Control Options
Self Diagnosis Features
NIM-Able
Choices Of Wired Or Wireless Remote Controller

Maximum air throw distance up to 16.5m.

Auto Air Swing

The Motorized louver enables the air flow to be evenly


distributed.

*Wall bracket is supplied as optional item.

Versatile Installation

The unit is designed to work with high pressure head drain


pump (optional). Thus offering flexibility for installation on
condensate drain pipe. The drain pump comes with a high
head and is incorporate with the float switch as safery
protection.
* Drain pump kit supplied as optional item

700mm

Service & Maintenance at Ease

The washable fitler can be easily accessed by just pulling


down the intake grill.
During servicing or repairing, only the bottom panel
needs to be removed in order to access the parts like fan
motor, blower, wiring connection, control box, piping
connection and so on.

Room Temperature Sensing

Able to sense the room temperature in order to perform


more controls for comfort.

Saranet Air Filter


The anti fungus air filter removes air-particles from the air.

16

17

Able to communicate with the versatile NIM networking


control module and oers the oppurtunity of one
centralized control for a system of multiple indoor units in

-2C
-3C

Heating mode*
ling

Temperature

NOMINAL RUNNING CURRENT

CONTROL

Cooling mode

AIR FLOW

FWE12E

33700

40000

4540

5950

6150

7270

9880

11720

Btu/h

12700

15400

16150

3720

4510

4730

Btu/h

19500

25000

28000

34500

46300

51600

5720

7330

8210

10110

13570

15120

86

135

160

0.38

0.67

0.79

N/A
AUTOMATIC LOUVER (UP & DOWN)

OPERATION

LCD WIRELESS MICRO-COMPUTER


REMOTE CONTROL

HIGH

CFM

520

580

640

MEDIUM

CFM

460

530

560

LOW

CFM

406

490

460

USGPM

3.43

4.49

4.67

17

17.68

Litres/min

HEAD LOSS (COOLING)


HEAD LOSS (HEATING) : 50

0C

13

kPa

27

48

57

kPa

24

42

50

kPa

MAX. WORKING PRESSURE

1608

SURFACE AIR VELOCITY

m/s

0.87

1.01

1.08

SOUND PRESSURE LEVEL (H/M/L)

dBA

45 / 38 / 36

46 / 43 / 39

49 / 46 / 41

UNIT DIMENSION

HXWXD

mm

212 X 1090 X 630

PACKING DIMENSION

HXWXD

mm

297 X 1197 X 740

UNIT WEIGHT

kg

27

CONDENSATE DRAIN SIZE

mm

19.05

PIPE CONNECTION

mm

12.7

TYPE

BLOWER

DRIVE

DIRECT

FAN

In case of sudden power failure during operation, unit


restarts automatically & unit will operate based on
previous setting when power is resumed.

Power Failure

Wireless Remote Controller Wired Remote Controller


BRC52A
BRC51A62

FAN SPEED

INDOOR UNIT

Auto Restart with Last-State-Memory

Stop

1220

1300

1400

MEDIUM

RPM

990

1100

1200

LOW

RPM

890

930

1000

INDEX OF PROTECTION (IP)

IP 20

INSULATION GRADE

B
HIGH

86

135

160

MEDIUM

58

97

113

LOW

51

83

91

HIGH

0.38

0.67

0.79

MEDIUM

0.26

0.45

0.52

LOW

0.23

0.39

0.44

STARTING CURRENT

5.2

10.3

24

MOTOR OUTPUT

50

65

70

RATED INPUT POWER

Restart

RATED RUNNING CURRENT

E PROM
2

POLES
TUBE

Setting stored before power failure.

RPM

INDUCTION

FAN MOTOR

Operation

HIGH

TYPE

Power Returns

COIL

4
MATERIAL

COPPER
mm

DIAMETER
MATERIAL

FIN

7.00
ALUMINUM

FACE AREA

0.27

Litre

1.41

ROW

WATER VOLUME
AIR QUALITY

COMING SOON

220-240 / 1 / 50

AIR DISCHARGE

NOMINAL WATER FLOW RATE

Hou

FWE10E

24800

REFRIGERANT TYPE

rs

0
Sleep 1/2
Set O 1
n

FWE08E

21000

V/Ph/Hz

POWER SOURCE

Compact and user friendly wireless BRC52A and wired


BRC51A remote controller offer :
Real Time Clock
"Glow in the dark" ON/OFF Button
Low, Medium, High fan speed options
ON Timer Setting

+1C

+0.5C

0C)

NOMINAL TOTAL INPUT POWER

Choices Of Wired Or Wireless Remote


Controller

Coo

+0.5C

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50

FWE07E

20300

SO
ON

NIM-Able

NOMINAL SENSIBLE COOLING CAPACITY

FWE06E

15500

-1C
n
ati
He

Self Diagnosis Features

FWE05E
Btu/h

FILTER

IN

Sleep Set
On
1/2
1

MODEL
NOMINAL COOLING CAPACITY

This feature helps to detect any faults or malfuctioning in


the system and provide user a warning by blinking of the
LED lights.
Ho
ur
s

Temperature

The design is flexible enough to allow for either valve or


valveless control installation.

Specication for Ceiling Convertible Type ~ 50Hz

Once activated, set temperature will be increased /


decreased gradually according to normal sleeping
temperature patterns to ensure a comfortable sleeping
environment.

Valve Or Valveless Control Options

CO

Sleep Function For Cool And Heat Mode

TYPE

WASHABLE SARANET FILTER

QUANTITY

CASING
MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

pc

COLOUR

WHITE
HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

18

19

Ceiling Concealed Type

Excellent Air Distribution

The air can be distributed evenly to every corner of the


room through ducting. This not only presents a
confortable environment, it also enables the installation of
multiple area by using only one fan coil unit.

Easy To Service

Direct access to control box at side panel and filter is


accessible from side panel too.

Left / Right Piping option

For flexible installation and application at site

4 Useable Fan Speed

Each speed offers different external static pressure and air


flow which enhances flexibility.

Wired Remote Controller


BRC51A

Valve Or Valveless Control Options

FWC-C

Excellent Air Distribution


Compact Design
High Capacity Range
High External Static Pressure Range
Double Protection Drainage
East To Service
Left/Right Piping Option

The design is flexible enough to allow for either valve or


valveless control installation
4 Useable Fan Speed
Valve Or Valveless Control Options
Self Diagnosis Features
NIM-Able
Auto Restart With Last-State-Memory
Choices Of Wired Or Without Wired Controller

Self Diagnosis Features

Ability to detect and diagnose faults and display as error


code in the wired controller.

Compact Design

Unit height as low as 266mm for installation at limited


ceiling space.

702mm

NIM-Able

Able to communicate with the versatile NIM networking


control module and offers the oppurtunity of one
centralized control for a system of multiple indoor units in
a building

Auto Restart With Last-State-Memory


266mm

In case of sudden power failure during operation, unit


restarts automatically & unit will operate based on
previous setting
Power Failure

351mm

Operation

Power Returns
Stop

Restart

High Capacity Range


From 3kW to 16kW.

E PROM
2

High External Static Pressure Range

Available up to 167Pa for high static application like the


ducting application.

Double Protection Drainage System

There are primary and secondary drain pan from the


standard model, which provide extra protection against
condensed or water leaking posibilities.

Setting stored before power failure.

Choices Of With Or Without Wired Remote


Controller
Compact and user friendly wired BRC51A remote controlleroffers:
Real Time Clock
"Glow in the dark" ON/OFF Button
Low, Medium, High fan speed options
ON Timer Setting

Filter Cover

Secondary Drain Pan


With Insulation

20

Primary Drain Pan


Polysterene (PS)
With High Impact
Polystyrene (HIPS)
Cover

Wired Remote Controller


BRC51A

21

Specication for Ceiling Concealed Type ~ 50HZ

Specication for Ceiling Concealed Type ~ 50Hz


MODEL

FWC03C
Btu/h

NOMINAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY


NOMINAL HEATING CAPACITY
(ENTERING WATER TEMP. = 50C)
NOMINAL TOTAL INPUT POWER

2900

11600

18000

3400

5280

8120

12600

15750

2380

3690

4620

NOMINAL SENSIBLE COOLING CAPACITY

531

0.86

1.50

2.28

1.93

1.86

2.32

0.40

168

0.65

0.77

POWER SOURCE

220-240 / 1 / 50

300
285
260

V/Ph/Hz

510

700

490

675

400

CONTROL

640

730
AIR FLOW

660
580

Pa

49 / 44 / 36

49 / 42 / 28

49 / 45 / 41

49 / 43 / 30

USGPM

2.20

2.60

4.05

5.06

N/A
AIR DISCHARGE
OPERATION
CFM

830

1250

1240

1340

1550

MEDIUM

CFM

760

1130

1100

1220

1400

LOW

CFM

710

1040

1020

1190

1300

Pa

167 / 128 / 88

118 / 108 / 88

128 / 88 / 39

157 / 137 / 108

157 / 137 / 98

EXTERNAL STATIC PRESSURE


NOMINAL WATER FLOW RATE

19.15
32.4

HEAD LOSS (COOLING)

kPa

14.0

39.0

23.0

38.0

51.0

27.6

HEAD LOSS (HEATING) : 50C

kPa

11.0

37.0

19.0

33.0

48.0

MAX. WORKING PRESSURE

kPa

8.8

20.3

17.0
1608

1.29

1.72

1.83

1.72

SURFACE AIR VELOCITY

m/s

1.40

1.74

1.83

1.54

1.52

SOUND PRESSURE LEVEL (H/M/L)

dBA

46 / 42 / 38

51 / 48 / 45

49 / 45 / 41

52 / 50 / 47

53 / 50 / 47

36 / 35 / 33

40 / 38 / 33

42 / 41 / 40

41 / 40 / 36

mm

267 x 702 x 351

267 x 842 x 351

267 x 1002 x 351

267 x 1137 x 351

UNIT DIMENSION

HXWXD

mm

384 x 917 x 462

316 x 1225 x 559

384 x 1003 x 462

384 x 1287 x 462

384 x 1487 x 462

PACKING DIMENSION

HXWXD

mm

415 x 1126 x 631

355 x 1461 x 727

415 x 1245 x 631

415 x 1497 x 631

415 x 1701 x 631

kg

42

47

44

50

56

mm

376 x 951 x 541

376 x 1091 x 541

376 x 1251 x 541

376 x 1386 x 541

kg

18

22

24

26

UNIT WEIGHT

RPM
RPM
RPM

1282
1221
1117

1331

1279

1263

1078

1348
1270
1072

140

168

182

86

128

165

175

127

163

163

W
A

0.40

0.65

0.77

0.86

MEDIUM

0.39

0.59

0.76

0.83

0.59

0.75

0.77

0.73

1.66

1.22

1.86

MOTOR OUTPUT

38

72

80

90

0.11
0.94

FAN MOTOR
RATED
RUNNING
CURRENT

MODE
ENTERING AIR TEMPERATURE

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C
12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND WIRED/WIRELESS REMOTE CONTROL OPTION

60C (4 Pipes System)

1268

1097

1203

1215

LOW

RPM

937

1169

913

1108

1067

IP20

IP20

IP20

IP21

345

504

442

427

531

MEDIUM

304

380

384

388

466

LOW

270

338

342

373

413

HIGH

1.50

2.28

1.93

1.86

2.32

1.34

1.72

1.69

1.69

2.02

1.21

1.53

1.54

1.63

1.81

STARTING CURRENT

2.43

2.77

3.18

3.50

4.90

MOTOR OUTPUT

310

470

355

373

500

0.48

4
MATERIAL

ALUMINIUM

MATERIAL

COIL
0.20

HIGH

DIAMETER

0.18

FIN

FACE AREA

COPPER
mm

WATER VOLUME

1.63
AIR QUALITY

FILTER

9.52
ALUMINIUM

ROW
1.43

IP22

TUBE

N/A
HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)

1303

1093

9.52

COLOUR

1284

RPM

MEDIUM

COPPER

WASHABLE SARANET FILTER


pc

1260

MEDIUM

LOW

POLES

1.15

TYPE

1381

INDUCTION

RATED
INPUT POWER

3
litre

1230

TYPE

0.14

ROW

RPM

INSULATION GRADE

89

HIGH

INDEX OF PROTECTION (IP)

MATERIAL

DIRECT

FAN SPEED

mm

19.05
BLOWER

FAN

IP20

MATERIAL

mm

19.05

DRIVE
1369

1385

mm

TYPE

INDOOR UNIT

INDOOR UNIT

1608

dBA

LEAVING WATER TEMPERATURE

11.62
43.98

20.1

STARTING CURRENT

CASING

10.04
38.00

15.33

HIGH

QUANTITY

8.28
31.34

9.84

0.35

FILTER

8.59
32.51

24.0

POLES

AIR QUALITY

5.55
21.01

8.33

78

WATER VOLUME

USGPM
litres/min

10.5

INDUCTION

FACE AREA

WIRED MICRO-COMPUTER REMOTE CONTROL

HIGH

kPa

INDEX OF PROTECTION (IP)

FIN

DUCTED

litres/min

INSULATION GRADE

COIL

220-240 / 1 / 50

REFRIGERANT TYPE

DIRECT

DIAMETER

19140

NOMINAL RUNNING CURRENT

140

TYPE

TUBE

65300

182

89

BLOWER

LOW

11990

54900
427

TYPE

RATED
RUNNING
CURRENT

10290
16090

DRIVE

FAN MOTOR

8590
48000
442

PIPE CONNECTION

LOW

8730
49200

14070

19.05

MEDIUM

5770
32800

504

19.05

HIGH

14420

mm

RATED
INPUT POWER

40900

345

mm

LOW

35100

9610

PIPE CONNECTION

MEDIUM

29300

CONDENSATE DRAIN SIZE

FAN SPEED

29800

CONDENSATE DRAIN SIZE

HIGH

19700

NOMINAL TOTAL INPUT POWER

kPa

FAN

15180

Btu/h

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50C)

m/s

HXWXD

13100

8500

SURFACE AIR VELOCITY

UNIT WEIGHT

10840

29000

MAX. WORKING PRESSURE

HXWXD

11140

6740

kPa

SOUND PRESSURE LEVEL (H/M/L)

7270

23000

CFM

HEAD LOSS (HEATING) : 50C

51800

4400

CFM

HEAD LOSS (COOLING)

FWC16C

44700

15000

CFM

NOMINAL WATER FLOW RATE

FWC14C

37000

3370

DUCTED

EXTERNAL STATIC PRESSURE

FWC12C

38000

11500

WIRED MICRO-COMPUTER REMOTE CONTROL

MEDIUM

FWC11C

24800

OPERATION

PACKING DIMENSION

NOMINAL COOLING CAPACITY

FWC09C
Btu/h

Btu/h

AIR DISCHARGE

UNIT DIMENSION

MODEL

Btu/h

N/A

LOW

22

6590

2050

HIGH
AIR FLOW

22500

7000

REFRIGERANT TYPE
CONTROL

FWC07C

V/Ph/Hz

POWER SOURCE

FWC06C

Btu/h

NOMINAL RUNNING CURRENT

9900

FWC04C

litre

0.28

0.34

0.32

0.41

2.21

2.66

2.60

3.33

3.80

WASHABLE SARANET FILTER

TYPE
QUANTITY

CASING
MODE
ENTERING AIR TEMPERATURE

pc

COLOUR

N/A

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND WIRED/WIRELESS REMOTE CONTROL OPTION

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

23

Ducted Blower Type

Excellent Air Distribution

The air can be distributed evenly to every corner of the


room through ducting. This not only presents a
confortable environment, it also enables the installation
of multiple area by using only one fan coil unit.

High External Static Pressure Range

Available up to 2256Pa for high static application like the


ducting application

Cabinet Construction

It is coated with weatherproofed electro galvanized mild


steel casing, with an epoxy is coated with an epoxy
polyester powder costing for sever external conditions.
Service panel is available at the convenience side as well.

Left / Right Piping option


FUD20/25B

For flexible installation and application at site.

FUD40/50B

Fire-Resistant
Excellent Air Distribution
4 Useable Fan Speed*
Easy To Service
Fire-Resistant Polysthylene Insulation
Left/Right Piping Option

Cabinet Construction
High External Static Pressure Range
ChangeableDrive Package*
Convertible Air Throw Direction*
High CFM Range

4 Useable Fan Speed*

Each speed offers different external static pressure and air


flow which enhances flexibility
*Only available for FUD20/25B

High CFM Range

Polyrethylene (PE) insulation is used at every possible


condensate panel to prevent all forms of water or moisture
penetration. Polyethylene, which is also a type of Closed
Cell Foam (CCF) insulation has offered the following
advantages:
Durable external surface that resists tough dirt and
resilient.
Higher degree of punsture resistance when compared
to fiberglass.
Easily cleaned surface (if necessary) to further resist
microbial growth.

Changable Drive Package*

From 20kW to 40kW and 2500CFM to 4600CFM.

Convertible Air Throw Direction*

Convertible discharge air direction (vertical or horizontal


air throw) provides flexibility in installation at site
*Only available for FUD30/40B

Changeable belt driven package offers flexibility in


customizing project based according to application
*Only available for FUD30/40B

Return
Air Grille

Duct
System
FUD Unit

Concrete
Plinth

Ducted Supply

Ducted Return
FUD Unit

Air Discharge Grille

24

Easy To Service

There is a service way allocated at the bottom for servicing


available for FUD20/25B

Return Air Grille

25

Specication for Ducted Blower Type ~ 50Hz


MODEL
NOMINAL COOLING CAPACITY

FUD20B

FUD25B

FUD30B

FUD40B

Btu/h

75600

95000

125000

150000

22160

27840

36640

43960

Btu/h

53700

69400

90000

106500

15740

20340

26380

31210

NOMINAL HEATING CAPACITY


(ENTERING WATER TEMP. = 50C)

Btu/h

78000

97500

138000

170000

22860

28580

40450

49820

NOMINAL TOTAL INPUT POWER

760

1800

1620

1910

NOMINAL RUNNING CURRENT

3.49

7.84

3.33

4.03

NOMINAL SENSIBLE COOLING CAPACITY

POWER SOURCE

AIR FLOW

AIR DISCHARGE

DUCTED

OPERATION

WITHOUT CONTROLLER

HIGH

CFM

2500

3200

4200

4600

MEDIUM

CFM

2100

3000

N/A

N/A

LOW

CFM

1750

2800

N/A

N/A

Pa

100 / 72 / 50

100 / 80 / 60

230

230

EXTERNAL STATIC PRESSURE

1
2
3
4

USGPM

16.90

21.10

27.70

33.30

litres/min

64.00

80.00

105.00

126.00

HEAD LOSS (COOLING)

kPa

34.5

42.0

48.8

53.3

HEAD LOSS (HEATING) : 50C

kPa

32.9

27.4

31.5

63.2

MAX. WORKING PRESSURE

kPa

2.15

NOMINAL WATER FLOW RATE

m/s

2.19

2.80

1.96

SOUND PRESSURE LEVEL

dBA

50/46/42

54/52/50

58

UNIT DIMENSION

HXWXD

mm

PACKING DIMENSION

HXWXD

mm
kg

572 x 1402 x 605


762 x 1605 x 880

1154 x 1787 x 1188

92

102

176

mm

19.05

PIPE CONNECTION

mm

28.58

TYPE
DIRECT

INDOOR UNIT

FAN SPEED

BELT

HIGH

RPM

835

950

707

707

MEDIUM

RPM

720

885

N/A

N/A

LOW

RPM

615

805

N/A

N/A

TYPE

INDUCTION
IP22

INDEX OF PROTECTION (IP)

INSULATION GRADE
HIGH

760

1800

1620

1910

MEDIUM

611

1620

N/A

N/A

LOW

478

1320

N/A

N/A

HIGH

3.49

7.84

3.33

4.03

MEDIUM

2.86

7.06

N/A

N/A

LOW

2.32

5.82

N/A

N/A

STARTING CURRENT

5.20

10.30

24.00

29.00

MOTOR OUTPUT

375

500

1500

2200

1.01

RATED
INPUT POWER
FAN MOTOR
RATED
RUNNING
CURRENT

POLES
TUBE

DIAMETER
FACE AREA

WATER VOLUME
FILTER

m
litre

0.54

0.54

1.01

4.53

6.27

8.14

11.63

WASHABLE SARANET FILTER


pc

QUANTITY

MODE
ENTERING AIR TEMPERATURE

BRC51A61 Heatpump with auto mode


BRC51A62 Cooling only

Features:
Cool/Heat/Fan/Dry/Auto mode
Auto/High/Med/Low fan speed
Temperature operate in C and F
Turbo and Quiet Function
Sleep function
Swing function
Real time clock and day display
7-days programmable timer
Error indicator
Key lock and fan lock features
Batteries backup and retain setting during power failure
Last state memory (Memory backup setting from main board)
Delay Timer (1 or 2 hours)
Interaction with Wireless Handset (BRC52A61/BRC52A62)

ALUMINIUM

TYPE

CASING

BRC51A

9.53

mm

MATERIAL
FIN

10
11
12

Vertical Automatic Air Swing


Selectable Mode:
Auto Mode, Cooling , Heating, Dry, Fan
3. Turbo Function
4. Quiet Function
5. ON Timer Setting
6. Real Time Clock
7. Transmission Source
8. Glow in the dark ON/OFF Button
9. Fan Speed Selection: Low, Med, High, Auto
10. Temperature Setting: Up & Down
11. Sleep Mode Function
12. OFF Timer Setting

COPPER

MATERIAL

ROW

AIR QUALITY

189

BLOWER

DRIVE

COIL

58
885 x 1540 x 850

CONDENSATE DRAIN SIZE

FAN

1.
2.

1608

SURFACE AIR VELOCITY

UNIT WEIGHT

COOLING
27C DB / 19C WB

ENTERING WATER TEMPERATURE

7C

LEAVING WATER TEMPERATURE

12C

AAF R29

COLOUR

ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING.

26

BRC52A61 Heatpump with auto mode


BRC52A62 Cooling only
BRC52A63 - Heatpump

N/A

REFRIGERANT TYPE
CONTROL

BRC52A

380-415 / 3 / 50

220-240 / 1 / 50

V/Ph/Hz

Controller

3
IVORY WHITE

HEATING
20C DB
50C (2 Pipes System)
70C (4 Pipes System)
60C (4 Pipes System)

27

Intelligent Control Series


Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.
With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller
giving you benefits:

Network Control NIM


Benets

More convenience. No more individually controlling air conditioning units


Quicker and easier zone control from the master control unit
Better control of air conditioning systems operating conditions
NIM utilizes master-slave type system whereby the master node will issue
commands to each of the slave nodes.

Supported Conguration
Master

Slave

BRC51A
BRC52A

Communication Bus

Connection

A 2-way twisted pair cable is used as the


communication bus. Recommended cable for
communication bus is a pair of screened &
shielded, twisted single core wire with core
diameter of 0.5mm to 1.0mm.

First NIM to the furthest


connected NIM
NIM to Main Board

10

NIM to Wired Controller

10

The communication bus must be connected serially to the adjacent NIM. (Daisy chain connection). The
same polarity has to be connected between the NIMs (A to A, B to B).

G-Way

The master unit will be operating in conjunction with a control panel. Any settings
done via the control panel connected to the master will overwrite the settings of its
slave units.

Function

Slave unit can be operated with or without control panel. If a slave unit is operating
with a control panel, its settings can be changed without following its master.

Gateway between DX fan coil unit and basic Building


Management System (BMS).

DIP switch setting for Group & Unit address.


Master or slave system configuration.
Automatic detection of control panel existence.
Error type and unit ID indication through display control panel.

The NIM System Consists Of


Main Board controller

Display control panel

NIM

Note:

Maximum point to point communication bus up to 1000m.


A single master unit can control up to 15 slave units in each group.
Each slave unit will sense their individual local temperature.
Unit address range from 0 to 15 (0000-1111).

NIM controller

Communications bus

Remote (On/O ) control of air conditioner via BMS.


Unit error indication via BMS and BRC51A controller.
Unit operation status monitoring via BMS.
Maximum point to point communication bus between air
conditioner and BMS of up to 1000m.
DIP switch setting for control or monitoring function.

(up to total of
16 FCUs)

DSW2 Setting

Slave

Slave(s)

Slave(s)

0000

Control & Monitor (Ext. Switch Open = ON A/C)

0010

Monitoring only

0001

To Wired Control Panel

Dry Contact
Input

Dry Contact
Switch

To MainBoard

CN1

RELAY 1

NO
COM

Dry Contact
Output 1

Unit On/O
Indicator

NO
COM

Dry Contact
Output 2

Unit Error
Indicator

RELAY 2

Main Board Controllers And Display Control Panel

28

DSW2 Setting

Control & Monitor (Ext. Switch Closed = ON A/C)

CN2

NIM must be used in conjunction with:


Fan coil units
BRC51A or BRC52A

G-Way

Types of Operation

Connection

Master

1000

Connection

Every master unit will have a group address so that every slave can only response
to their respective master. Each slave unit must have a unique address so that it can
be addressed independently of other nodes.

Basic Features

Recommended Maximum Cable Length (m)

DIP Switch

Terminal
Blocks

G-Way Controller

1000 m

BMS

29

S-NIM For Timer Switchover Control

Built on the NIM configuration, S-NIM serves to enhance the


abilities and extend the operating lifetime of existing air
conditioning units in harsh and demanding environment.
S-NIM works in a master & slave system, operating at
alternate sequence of preset hours. Whenever the operating
unit is at fault, the standby unit will automatically takes over.

S-NIM
Features

Auto restart feature with last state settings.


2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12
hours).
System controlled by a single BRC51A controller.
When the operating unit is at fault, the standby unit automatically takes over.
Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)
During system OFF mode, running timer will stop. It resumes when changing to ON mode.
Preset operation hours can be set via DIP Switch.
* The air conditioning unit connected to the wired controller is always the master unit.

The S-NIM System Consists Of


Main Board controller
BRC51A

S-NIM controller
Communication Bus

Communication Bus
A 2-way twisted pair cable is used as the communication bus.
Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter
of 0.5mm to 1.0mm.

S-NIM Controller Application

Server Room
Telecommunication Tower
Livestock Breeding Farm
Warehouse

Main Board

S-NIM

Laboratory
Railway Switching Center
Room with Critical Electronics Equipments

Main Board

S-NIM

Slave Unit

Control Panel

Master Unit

Typical connection structure for S-NIM

30

You might also like