950 3-3 P5ZR 30 Pag 650-100
950 3-3 P5ZR 30 Pag 650-100
950 3-3 P5ZR 30 Pag 650-100
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fans:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
16
1600
Pw (1)
12
1400
1200
1000
800
600
400
1800
200
pst (1)
0
0
10000
20000
30000
40000
50000
Air flow (Q) [m/h]
pst=Static pressure
Pw=Power consumption
2016 WingFan
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Fan: 950/3-3/P5ZR/30/PAG
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Operating point:
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
Fan
Diameter range:
Temperature range:
Tip-speed/Max.:
Max. rotation speed (50 C):
Air velocity:
Torque:
Moment of inertia:
Axial thrust:
326 - 1,066 mm
-40 - 110 C
120.4/120 m/s
2,412 min-
14 m/s
37.04 Nm
0.09349 kgm
450.7 N
Performance/blade:
4.2 hp
Weight (approx.):
2.2 kg
Hub
Bearing surface :
110 mm
Total thickness:
7 mm
Outer diameter:
191 mm
Blade
v/h:
v1/h1:
Length:
22/47 mm
-1 (0)/16 (17) mm
385 (386) mm
2016 WingFan
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
General:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Natural frequencies of the fan blades vs. Excitation frequencies of the rotation speed
180
160
140
Frequency [Hz]
120
100
80
60
40
20
0
1300
1500
1700
1900
2100
2300
2500
2700
2900
3100
3300
3500
37
00
Natural frequency 2
Excitation freq. 1x
Natural frequency 1
Natural frequency 3
Excitation freq. 2x
Excitation freq. 3x
2016 WingFan
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fan: 950/3-3/P5ZR/30/PAG
Number of fans:
Distance to sound source:
Number of reflectors:
Operating point:
1
1m
1
Air flow:
Static pressure:
Power:
tot:
stat:
63
125
250
500
1k
2k
4k
8k
Lin
93
100
96
95
93
90
87
84
103
67
84
87
92
93
91
88
83
98
85
92
88
87
85
82
79
76
95
59
76
79
84
85
83
80
75
90
Attenuation [dB]
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
2016 WingFan
The obtained sound values are to be regarded as a guideline. They are based on aerodynamic ideal conditions and free sound propagation. The
values are not transferrable to entire facilities with additional noise sources caused by drive or structure-borne noise.
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fan: 950/3-3/P5ZR/30/PAG
Number of fans:
Distance to sound source:
Number of reflectors:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Operating point:
1
1m
1
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
100
93
96
103
95
93
80
90
87
2k
4k
84
60
40
20
0
63
125
250
500
1k
8k
Lin
2016 WingFan
The obtained sound values are to be regarded as a guideline. They are based on aerodynamic ideal conditions and free sound propagation. The
values are not transferrable to entire facilities with additional noise sources caused by drive or structure-borne noise.
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fan: 950/3-3/P5ZR/30/PAG
Number of fans:
Distance to sound source:
Number of reflectors:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Operating point:
1
1m
1
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
80
60
87
92
93
98
91
88
83
67
40
20
63
125
250
500
1k
2k
4k
8k
Lin
2016 WingFan
The obtained sound values are to be regarded as a guideline. They are based on aerodynamic ideal conditions and free sound propagation. The
values are not transferrable to entire facilities with additional noise sources caused by drive or structure-borne noise.
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fan: 950/3-3/P5ZR/30/PAG
Number of fans:
Distance to sound source:
Number of reflectors:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Operating point:
1
1m
1
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
85
95
88
87
85
82
79
76
60
40
20
63
125
250
500
1k
2k
4k
8k
Lin
2016 WingFan
The obtained sound values are to be regarded as a guideline. They are based on aerodynamic ideal conditions and free sound propagation. The
values are not transferrable to entire facilities with additional noise sources caused by drive or structure-borne noise.
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com
1/17/2017
Fan description:
Diameter:
No. of blades:
Hub size:
Blade profile:
Rotation direction:
Pitch angle:
Blade material:
General:
950 mm
3
3
P5Z
R
30
PAG
Application data:
Application:
Drive type:
Fan drive:
Stationary cooler
Combustion engine
No
Simulation:
none
Installation type:
Tip clearance:
Rotation speed:
Temperature:
Altitude:
Air density:
Fan: 950/3-3/P5ZR/30/PAG
Number of fans:
Distance to sound source:
Number of reflectors:
Orifice plate
1%
2,420 min-
50 C
0m
1.09 kg/m
Operating point:
1
1m
1
Air flow:
Static pressure:
Power:
tot:
stat:
37,289 m/h
403.6 Pa
12.59 hp
57 %
45 %
80
76
60
79
84
85
90
83
80
75
59
40
20
63
125
250
500
1k
2k
4k
8k
Lin
2016 WingFan
The obtained sound values are to be regarded as a guideline. They are based on aerodynamic ideal conditions and free sound propagation. The
values are not transferrable to entire facilities with additional noise sources caused by drive or structure-borne noise.
Remarks:
Max. tip-speed exceeded!
Direct assembly on the crank shaft is not admissible. An appropriate isolation is to be provided.
info@wingfan.com
www.wingfan.com