VCB 5678 Catalogue
VCB 5678 Catalogue
VCB 5678 Catalogue
sustainable solution
L&T Electrical and Automation is a part of the multi-billion dollar technology, engineering, construc-
tion, manufacturing and services conglomerate. The Company designs, manufactures and markets a
wide range of low voltage and medium voltage electrical systems, control and automation systems,
electrical products and metering and protection systems.
Our core strength in engineering and MV product development, bolstered by strong R&D with
TAMCO, enables us to deliver the most comprehensive, best-in-class electrical solutions to our diverse
customer base.
Safety
VH - AIS
Reliability
Convenience
VH - AIS
Reliability
Convenience
IEC62271-100
High Voltage Circuit Breakers (1 kV - 52 kV)
IEC62271-200
High Voltage Metal Enclosed Switchgear (1 kV - 52 kV)
IEC62271-102
High Voltage Disconnectors & Earthing Switches
IEC62271-106
High Voltage Contactors (for Controllers & Motor Starters)
Safety
Honored protector
VH - AIS is a robust metal-clad switchgear, divided into four
distinct compartments (busbar, circuit breaker, cable and
low voltage equipment) segregated by earthed metal
panels, to assure your protection against electric shock.
Extreme independence of
environment
VH - AIS gives you protection against access to hazardous
parts and solid foreign bodies and is designed & engineered
to perform satisfactorily in harsh and corrosive environment
Ingress protection with dust and pollution.
IP4X
Touch protective
The earthed metallic, spring operated shutters ensure
protection against accidental contact even when the
breaker is isolated or withdrawn.
How?
Our type-tested VH - AIS also accomplishes the provisions of internal Arc fault
withstand stest as per IEC 62271-200 in all aspects.
Criterion VH-AIS
Earthing Switch
Safeguarding of operating personnel is achieved by
providing make-proof earthing switch for cable, as well as
busbar compartments.
Safety First
Reliability
Surface protector
The 9-tank pre-treatment paint process along with powder
coating with robotic paint applicator ensures that your
cubicle has a long lasting, high-gloss finish and is optimally
protected against corrosion and weathering.
Infinite cycles
Our Vacuum Circuit Breakers require minimal maintenance
and have a design life of 20 years or 10,000 mechanical
operations.
Dynamic driver
Our AIS systems are seismically qualified. They are enhanced
for rigidity and tested for stable operation in earthquake
prone areas up to Zone V as per latest codes & standards.
A Global validation
VH - AIS is completely type-test-verified at
reputed international third-party laboratories
to assure you best-in-class products.
CPRI ERDA KEMA CESI ASTA
Factory specialist
The performance of your assemblies is guaranteed by
carrying out the following checks as our routine factory
test plan:
Electrical tests
Visual Checks
Measurement Checks
Mechanical tests
Physical tests
Convenience
Smart addition
Panel coupling at site is made simple and safe through easily
accessible bus bar connections and links.
Stay connected
Our Vacuum Circuit Breakers and Contactor Units are truck-
mounted, the movement of which is interlocked with the
door to make it very convenient for your operators.
Ergonomic
VH-AIS comes with a single-handle for opening and closing
the breaker door, eliminating fasteners. This makes the
operation quick and easy.
Convenience
Minimum Footprint.
Optimum Utilisation.
VH - AIS can accommodate 2 VCBs / VCUs in a single vertical
section, thereby saving space.
Visual appeal
The detailed instructions about operations & interlocks
are screen printed on the VCB compartment door for
convenience.
19
D
13
A B C
9
12
1
16
2
3
4 20
5
6 17
18
7
10 15 11 14
02 - VCB door handle & padlocking 09 - Routing Interpanel wires 16 - Rear Door Interlock
Customised
05 - Viewing window for VCB ON/OFF 12 - VCB safety shutters 19 - Gas Duct
& Spring charging status indication
13 - Pressure relief flaps 20 - Voltage Detecting
06 - VCB Racking slot Insulator
14 - Power cable entry
07 - Earth switch operating slot
Construction
Typical configurations
- Busbar - Line PT
- Metering - Cable
- Bus PT
Technical Specifications
Type C
A (F, L,R), 40kA, up to 1s
IEC Standard IEC 62271-106
VCU Type Non Latched Latched
Type Designation VCU7N200 VCU7N400 VCU7L200 VCU7L400
Opening time < 35 ms
VCU Mechanical Endurance up to 3 Million up to 0.3 Million
Electrical Endurance up to 0.3 Million (AC-3)
Technical Specifications
25 / 26.3 kA
Short Time Withstand Current (3s)
Current ratings 40 / 50 kA
62.5 / 65.75 kAp
Short Circuit Making current
100 / 125 kAp
Width# 600 mm 800 mm 1000 mm
Dimension Depth # 1570 / 1970 / 2170 / 2270 mm
Height 2495 mm
Partition Class PM
Loss of Service continuity LSC-2B
Construction
Degree of protection IP4X (Higher IP on request)
Internal Arc Classification A (F, L,R), up to 40 / 50kA , up to 1s
IEC Standard IEC 62271-100
Type Designation VK series
Operating Sequence O-0.3sec-CO-3min-CO
Opening time < 35 ms
VCB Break time < 3 cycles
Mechanical Operations 10,000
Closing /Tripping Coil 24 / 48 / 110 / 220 V DC
Technical Specifications
L&T's VH - AIS offers the widest range of electrical solutions up to 36kV. Our In-house design and testing facilities
enable us to create customized solutions with type tested switchboard combining VCBs and VCUs in perfectly matched
configuration as per your requirements. We ensure that you achieve the highest level of cost & design optimisation with
our VH - AIS.
Larsen & Toubro Limited, Electrical Systems & Equipment - Head Of ce Registered Of ce:
7C, TC II, Tower B, Level 7, L&T Gate No. 5, Saki Vihar Road, Powai, Mumbai 400 072. L&T House, N. M. Marg
Tel: +91-22-6705 1748 Fax: +91-22-6705 1556 Ballard Estate
Mumbai 400 001, INDIA
Email: ese-cmt@Lntebg.com Website: www.lntebg.com
The information contained herein is correct at time of printing, but as the products and its manufacturing processes are being developed continuously,
this information is subject to change without notice and the company cannot be held liable for any alleged misinterpretation howsoever arising.