eSH Technical Catalog PDF
eSH Technical Catalog PDF
eSH Technical Catalog PDF
e-SH Series
CENTRIFUGAL ELECTRIC PUMPS ACCORDING TO EN 733
MADE IN AISI 316 STAINLESS STEEL AND EQUIPPED WITH IE3 MOTORS
ErP 2009/125/EC
Through the Directives 2005/32/EC, energy-using products (EuP), and 2009/125/EC, energy-related products
(ErP) a framework for ecodesign requirements was established.
The Commission Regulations (EC) No 640/2009 and (EU) No 4/2014 have implemented two directives with re-
gard to ecodesign requirements for three-phase 50 Hz electric motors placed on the market and put into
service inside EU zone as self-alone units or integrated in other products.
This regulation states that motors must have efficiency level IE3 (or IE2 + Variable Speed Drive) from
1st January 2015 for 7,5 to 375 kW rated powers and from 1st January 2017 for 0,75 to 375 kW ones.
The Commission Regulation (EU) No 547/2012 has implemented two directives with regard to ecodesign requi-
rements for some types of clean water pumps placed on the market and put into service inside EU zone as
self-alone units or integrated in other products.
This regulation states that water pumps shall have index MEI 0.4 as minimum from 1st January 2015.
That index comes from a dedicated formula which considers hydraulic efficiency values at best efficiency point
(BEP), 75 % of the flow at BEP (Part load PL) and 110 % of the flow at BEP (Over load OL).
The e-SH series, for the models in the scope of the regulations above, is ErP com-pliant,
having an index MEI equal or higher than 0,4 and IE3 motor efficiency.
HYDROVAR, Xylect are trademarks or registered trademarks of Xylem Inc. or one of its subsidiaries. All
other trademarks or registered trademarks are property of their respective owners
2
CONTENTS
5
General Introduction ........................................................................................................................
6
Applications .......................................................................................................................................
8
Identification code .............................................................................................................................
9
Rating plate .......................................................................................................................................
3
e-SH SERIES
HYDRAULIC PERFORMANCE RANGE AT 50 Hz
4
e-SH SERIES
GENERAL INTRODUCTION
The new and improved e-SH Series is a high performance stainless steel centrifugal end-suction electro-pump
with single stage, axial flanged suction port, radial flanged discharge, and horizontal shaft.
The e-SH is fully made in AISI 316 stainless steel which makes it suitable for handling water as well as non-
aggressive or moderately aggressive fluids.
The pumps are equipped with intercheangeable mechanical seals, IE3 efficiency motors, and have a back pull-out
design (impeller, bracket and motor can be extracted without disconnecting the pump body from the piping).
The e-SH series pumps are available in the following constructions:
* Fluoro-elastomer: FPM (old ISO), FKM (ASTM & new ISO). Note
Anti-clockwise rotation when facing pumps suction port.
Pump does not include counter-flanges.
5
e-SH SERIES
COMMERCIAL BUILDING SERVICES (CBS)
APPLICATIONS & BENEFITS
Applications
The e-SH Series is suitable for many different applications demanding reliable and efficient products that require
constant or variable duty points in cost saving operation.
HVAC
- Liquid transfer in heating and air-conditioning
systems.
- Liquid transfer in ventilation systems.
- Liquid transfer with mildly aggressive liquids or
environment.
Water Supply
- Pressure boosting in commercial buildings.
- Irrigation systems.
- Water transfer for green houses.
Benefits
The e-SH Series permit to achieve the following benefits.
Performances: the e-SH pumps are ErP 2015 compliant, equipped with IE3 motors and provide improved
performance vs. the current SH series of pumps. Its AISI 316 material configuration makes it ideal for pumping
mildly aggressive liquids or pumping in aggressive environment. With a standard version designed for up to PN12
pressure rating, 120 C maximum fluid temperature, and FPM elastomer, and easy maintenance, the e-SH provides
the solution to many CBS needs.
Reliability: the high quality in production, the robust construction and operation, the easily interchangeable
mechanical seals, and wear rings guarantee a continuous operation without faults and a shorter down time for
maintenance.
Total cost ownership: the best hydraulic and electric efficiency, the HYDROVAR -equipped versions, the easy
and quick maintenance, permit to reduce the operation and maintenance cost and to save energy when the pump
is working.
Pre-post sales support: we are continuously working close to our customers to help them in selecting the
right pump for the specific application. An improved user-friendly selection software improved with many selection
tools is available on the website, on DVD or on Apps for mobile phones. Experienced engineers are fully dedicated
to big projects for Municipality.
Features
6
e-SH SERIES
for INDUSTRY
APPLICATIONS & BENEFITS
Applications
The e-SH Series is suitable for many different applications demanding reliable and efficient products. The
reliability, robustness, and AISI 316 material configuration of the e-SH series makes it ideal for use in aggressive envi-
ronments or for pumping of mildly aggressive fluids. Finally
the e-SH series compactness and reliability allows for use in
diverse OEM applications.
Benefits
The e-SH Series permit to achieve the following
benefits:
Features
7
ESH SERIES
IDENTIFICATION CODE
E S H F 6 5 - 1 6 0 / 1 1 0 A / P 2 5 V S N A
60 Hz
6F = 1x220-230 V
6E = 1x200-210 V
6P = 3x220-230/380-400 V
6R = 3x255-277/440-480 V
6V = 3x440-480/- V
6U = 3x380-400/660-690 V
6N = 3x200-208/346-360 V
6T = 3x330-346/575-600 V
EXAMPLES
ESHS 80-200/300/W25VSNA
End-suction, electric pump with stub shaft coupling, DN 80 nominal discharge port, 200 mm nominal impeller diameter, 30 kW rated motor power,
WEG IE3 model, 2-pole, 50 Hz 380-415/660-690 V, fabricated stainless steel casing, cast stainless steel impeller, Ceramic/Carbon/FPM mechanical
seal.
ESHF 80-160/22A/P45RSNA
End-suction, electric pump with frame mounted coupling, DN 80 nominal discharge port, 160 mm nominal impeller diameter, 2,2 kW rated motor
power, trimmed impeller, PLM IE3 model, 4-pole, 50 Hz 220-240/380-415 V, fabricated stainless steel casing, cast stainless steel impeller, Ceramic/
Carbon/FPM mechanical seal.
ESH 50-250/D224SSA
End-suction, bare shaft pump, DN 50 nominal discharge port, 250 mm nominal impeller diameter, 224 mm actual impeller diameter, fabricated
stainless steel casing, fabricated stainless steel impeller, Ceramic/Carbon/FPM mechanical seal.
8
ESH SERIES
RATING PLATE
TYPE No/Date
PN kPa tmax C tmin C Code Kg
F mm Q m/h H m n 1/min P2 kW F MEI T p%
T mm
REGULATION (EU) No 547/2012
3 4 6 5 15 14
1 13 12 10 9 2 7 8 1 13 12 10 9 2 7 8
11 19 3 4 6 5 15 14 11 19 3 4 6 5 15 14
LEGEND
1 - Pump / Electric pump unit type 10 - Trimmed impeller diameter (only filled-in for
2 - Pump / Electric pump unit code models with trimmed impellers)
3 - Flow range 11 - Minimum operating liquid temperature
4 - Head range 12 - Maximum operating liquid temperature
5 - Nominal or maximum pump power 13 - Maximum operating pressure
6 - Speed 14 - Hydraulic efficiency in best efficiency point
7 - Serial number or order number 15 - Minimum efficiency index MEI (Regulation (EU)
8 - Order position number No 547/2012)
9 - Full impeller diameter (only filled in for trimmed 19 - Weight
impellers)
9
ESH SERIES
ESH SERIES
LIST OF
LIST OFMODELS
MODELSAT AT
50 Hz,
50 2Hz,
POLES
2 POLES
SIZE kW VERSION SIZE kW VERSION
ESH..2 ESHE..M ESHE ESHS ESHF ESHC ESH..2 ESHE..M ESHE ESHS ESHF ESHC
25-125/07 0,75 - 65-160/40 4 -
25-125/11 1,1 - 65-160/55 5,5 -
25-160/15 1,5 - 65-160/75 7,5 -
25-160/22 2,2 - 65-160/92 9,2 - - - -
25-200/30 3 - - 65-160/110A 11 - -
25-200/40 4 - - 65-160/110 11 -
25-250/55 5,5 - - 65-200/150 15 -
25-250/75 7,5 - - 65-200/185 18,5 -
25-250/110 11 - - 65-200/220 22 -
32-125/07 0,75 65-250/300 30 - -
32-125/11 1,1 65-250/370 37 - -
32-160/15 1,5 80-160/110 11 -
32-160/22 2,2 80-160/150 15 -
32-200/30 3 - 80-160/185 18,5 -
32-200/40 4 - 80-200/220 22 -
32-250/55 5,5 - 80-200/300 30 - -
32-250/75 7,5 - 80-200/370 37 - -
32-250/110 11 - 80-250/450 45 - - -
40-125/11 1,1 80-250/550 55 - - -
40-125/15 1,5 80-250/750 75 - - -
40-125/22 2,2
40-160/30 3 -
40-160/40 4 -
40-200/55 5,5 -
40-200/75 7,5 -
40-250/92 9,2 - - - -
40-250/110A 11 - -
40-250/110 11 -
40-250/150 15 -
50-125/22 2,2
50-125/30 3 -
50-125/40 4 -
50-160/55 5,5 -
50-160/75 7,5 -
50-200/92 9,2 - - - -
50-200/110A 11 - -
50-200/110 11 -
50-250/150 15 -
50-250/185 18,5 -
50-250/220 22 -
= Available ESH_models-2p50-en_a_sc
LEGEND
10
ESH SERIES
ESH SERIES
LIST OF
LIST OFMODELS
MODELSATAT
50 50
Hz, Hz,
4 POLES
4 POLES
SIZE kW VERSION SIZE kW VERSION
ESH..4 ESHE ESHS ESHF ESHC ESH..4 ESHE ESHS ESHF ESHC
25-125/02A 0,25 - - 65-200/15 1,5 -
25-125/02 0,25 - - 65-200/22 2,2 -
25-160/02A 0,25 - - 65-200/30 3 -
25-160/02 0,25 - - 65-250/40 4 -
25-200/03 0,37 - - 65-250/55 5,5 -
25-200/05 0,55 - - 80-160/15 1,5 -
25-250/07 0,75 - 80-160/22A 2,2 -
25-250/11 1,1 - 80-160/22 2,2 -
25-250/15 1,5 - 80-200/30 3 -
32-125/02A 0,25 - - 80-200/40 4 -
32-125/02 0,25 - - 80-250/55 5,5 -
32-160/02A 0,25 - - 80-250/75 7,5 -
32-160/02 0,25 - - 80-250/110 11 -
32-200/03 0,37 - -
32-200/05 0,55 - -
32-250/07 0,75 -
32-250/11 1,1 -
32-250/15 1,5 -
40-125/02A 0,25 - -
40-125/02 0,25 - -
40-160/03 0,37 - -
40-160/05 0,55 - -
40-200/07 0,75 -
40-200/11 1,1 -
40-250/11 1,1 -
40-250/15 1,5 -
40-250/22 2,2 -
50-125/02 0,25 - -
50-125/03 0,37 - -
50-125/05 0,55 - -
50-160/07 0,75 -
50-160/11 1,1 -
50-200/11 1,1 -
50-200/15 1,5 -
50-250/22A 2,2 -
50-250/22 2,2 -
50-250/30 3 -
= Available ESH_models-4p50-en_a_sc
11
DENOMINAZIONE MODELLI
ESHE SERIES SERIE SHE - SHE4 CON
ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS
STAFFA DI SOSTEGNO
(ESHE) VERSIONS
2 POLES 4 POLES
25-125/07 25-200/05
25-125/11 25-250/07
25-160/15 25-250/11
25-160/22 25-250/15
25-200/30 32-200/05
25-200/40 32-250/07
25-250/55 32-250/11
25-250/75 32-250/15
25-250/110 40-160/05
32-125/07 40-200/07
32-125/11 40-200/11
32-160/15 40-250/11
32-160/22 40-250/15
32-200/30 40-250/22
32-200/40 50-125/05
32-250/55 50-160/07
32-250/75 50-160/11
32-250/110 50-200/11
40-125/11 50-200/15
40-125/15 50-250/22A
40-125/22 50-250/22
40-160/30 50-250/30
40-160/40 65-200/15
40-200/55 65-200/22
40-200/75 65-200/30
40-250/92 65-250/40
40-250/110 65-250/55
50-125/22 80-160/15
50-125/30 80-160/22A
50-125/40 80-160/22
50-160/55 80-200/30
50-160/75 80-200/40
50-200/92 80-250/55
50-200/110 80-250/75
65-160/40
65-160/55
65-160/75
65-160/92
65-160/110
80-160/110
MATERIALI ESHE ESHE-p-en_a_mo
12
ESHE SERIES
ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS
DENOMINAZIONE MODELLI
SERIE ESHE CON PIEDE DI
SOSTEGNO SUL MOTORE
(ESHE) VERSIONS
2 POLES 4 POLES
40-250/150 80-250/110
50-250/150
50-250/185
50-250/220
65-200/150
65-200/185
65-200/220
80-160/150
80-160/185
80-200/220
ESHE-s-en_a_mo
DENOMINAZIONE MODELLI
SERIE SHE4 CON MOTORE
MEC 71 B5
(ESHE) VERSIONS
4 POLES
25-125/02A 40-125/02A
25-125/02 40-125/02
25-160/02A 40-160/03
25-160/02 50-125/02
25-200/03 50-125/03
32-125/02A
32-125/02
32-160/02A
32-160/02
32-200/03
ESHE4-p-en_a_mo
MATERIALI ESHE
13
DENOMINAZIONE MODELLI
ESHS SERIES SERIE ESHS - ESHS4 CON
ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS
STAFFA DI SOSTEGNO
(ESHS) VERSIONS
2 POLES 4 POLES
25-125/07 25-250/07
25-125/11 25-250/11
25-160/15 25-250/15
25-160/22 32-250/07
25-200/30 32-250/11
25-200/40 32-250/15
25-250/55 40-200/07
25-250/75 40-200/11
32-125/07 40-250/11
32-125/11 40-250/15
32-160/15 40-250/22
B5 32-160/22 50-160/07
32-200/30 50-160/11
32-200/40 50-200/11
32-250/55 50-200/15
32-250/75 50-250/22A
40-125/11 50-250/22
40-125/15 50-250/30
40-125/22 65-200/15
40-160/30 65-200/22
40-160/40 65-200/30
40-200/55 65-250/40
40-200/75 65-250/55
50-125/22 80-160/15
50-125/30 80-160/22A
50-125/40 80-160/22
50-160/55 80-200/30
50-160/75 80-200/40
65-160/40 80-250/55
65-160/55 80-250/75
65-160/75
14
ESHS SERIES
ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS
DENOMINAZIONE MODELLI
SERIE ESHS CON PIEDE DI
SOSTEGNO SUL MOTORE
(ESHS) VERSIONS
2 POLES 4 POLES
25-250/110 80-250/110
32-250/110
40-250/110A
40-250/110
B35 40-250/150
50-200/110A
50-200/110
50-250/150
50-250/185
50-250/220
65-160/110A
65-160/110
65-200/150
65-200/185
65-200/220
65-250/300
65-250/370
80-160/110
80-160/150
80-160/185
80-200/220
80-200/300
80-200/370
ESHS-s-en_a_mo
MATERIALI ESHS
15
ESH, ESHF, ESHC SERIES
ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS
B3 DENOMINAZIONE MODELLI
SERIE ESHF
VERSIONS
ESH, ESHF, ESHC
25-125
25-160
25-200
25-250
32-125
32-160
32-200
32-250
40-125
40-160
40-200
40-250
50-125
50-160
50-200
50-250
65-160
65-200
65-250
80-160
80-200
80-250
ESHF-p-en_a_mo
MATERIALI ESHF
16
ESH SERIES
MECHANICAL SEAL
Mechanical seal with mounting dimensions according to EN 12756 and ISO 3069.
17
ErP 2009/125/EC
ESH SERIES
MOTORS
Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament
and the Council to adopt specific measures to the purpose of reducing energy consumption and further negative
environmental impacts.
Through the Directives 2005/32/EC, energy-using products (EuP), and 2009/125/EC, energy-related products (ErP)
a framework for ecodesign requirements was established.
The Commission Regulations (EC) No 640/2009 and (EU) No 4/2014 have implemented two directives with regard
to ecodesign requirements for electric motors placed on the market and put into service inside EU zone as self-alone
units or integrated in other products.
The various types considered include three-phase 50 Hz surface motors with power outputs ranging from
0,75 to 375 kW included.
ESHE SERIES
MOTORI MONOFASE PER SERIE SHE 50 Hz, 2 poli
SINGLE-PHASE MOTORS AT 50 Hz, 2 POLES
INPUT CAPACITOR DATA FOR 230 V 50 Hz VOLTAGE
Construction
IEC SIZE*
Design
CURRENT
PN In (A) Tn
MOTOR TYPE
-1
kW 220-240 V F V min ls / ln % cos
Nm Ts/Tn Tm/Tn
0,75 SM90RB14S2/1075 90R B14 4,83-5,23 30 450 2875 5,28 71,8 0,92 2,49 0,70 2,59
1,1 SM90RB14S2/1115 90R B14 6,88-6,65 30 450 2800 3,89 74,7 0,96 3,75 0,46 1,72
1,5 SM90RB14S2/1155 90R B14 9,21-8,58 40 450 2810 4,00 76,1 0,98 5,15 0,39 1,74
2,2 PLM90B14S2/1225 90 B14 12,5-11,6 70 450 2825 4,47 82,4 0,97 7,43 0,53 1,87
* R = Reduced size of motor casing as compared to shaft extension and flange. ESHE-motm-2p50-en_a_te
18
ESHE SERIES
MOTORI TRIFASE PER SERIE ESHE 50 Hz, 2 poli
THREE-PHASE MOTORS AT 50 Hz, 2 POLES
Efficiency N
manufacture
%
Year of
220 V 230 V 240 V 380 V 400 V 415 V
PN Y 380 V Y 400 V Y 415 V Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,75 82,5 83,1 81,3 82,8 82,7 80,1 82,6 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9
1,1 84,0 84,7 83,4 84,4 84,5 82,5 84,3 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4
1,5 85,6 86,5 85,8 85,9 86,4 84,9 86,0 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0
2,2 86,5 87,4 86,8 86,4 86,9 85,7 86,6 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0
from 11/2014
3 87,2 88,5 88,3 87,5 88,2 87,5 87,5 87,8 86,4 87,2 87,8 86,4 87,2 87,8 86,4 87,2 87,8 86,4
4 89,1 90,1 89,2 89,1 90,1 89,2 89,1 90,1 89,2 89,1 90,3 90,4 89,6 90,4 89,9 89,6 90,1 89,2
5,5 89,5 89,6 88,0 89,5 89,6 88,0 89,5 89,6 88,0 89,5 90,3 89,9 89,7 90,0 89,0 89,6 89,6 88,0 3
7,5 90,6 90,5 89,0 90,6 90,5 89,0 90,6 90,5 89,0 90,6 91,0 90,2 90,8 90,8 89,6 90,7 90,5 89,0
9,2 90,8 91,0 89,7 90,8 91,0 89,7 90,8 91,0 89,7 90,8 91,4 90,8 91,1 91,3 90,3 91,1 91,0 89,7
11 91,3 92,0 91,1 91,3 92,0 91,1 91,3 92,0 91,1 91,3 92,2 92,2 91,6 92,2 91,7 91,7 92,0 91,1
15 92,5 92,4 91,2 92,5 92,4 91,2 92,5 92,4 91,2 92,7 93,3 92,9 93,1 93,3 92,7 92,5 92,4 91,2
18,5 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,2 93,0 92,9 93,3 92,8 92,9 93,1 92,4
22 93,0 92,7 91,3 93,0 92,7 91,3 93,0 92,7 91,3 93,0 93,2 92,4 93,1 93,0 91,9 93,0 92,7 91,3
Manufacturer
Construction
Design
19
ESHS SERIES
MOTORI TRIFASE PER SERIE ESHS 50 Hz, 2 poli
THREE-PHASE MOTORS AT 50 Hz, 2 POLES (up to 22 kW)
Efficiency N
manufacture
%
Year of
220 V 230 V 240 V 380 V 400 V 415 V
PN Y 380 V Y 400 V Y 415 V Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,75 82,5 83,1 81,3 82,8 82,7 80,1 82,6 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9
1,1 84,0 84,7 83,4 84,4 84,5 82,5 84,3 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4
1,5 85,6 86,5 85,8 85,9 86,4 84,9 86,0 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0
2,2 86,5 87,4 86,8 86,4 86,9 85,7 86,6 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0
from 11/2014
3 87,2 88,5 88,3 87,5 88,2 87,5 87,5 87,8 86,4 87,2 87,8 86,4 87,2 87,8 86,4 87,2 87,8 86,4
4 89,1 90,1 89,2 89,1 90,1 89,2 89,1 90,1 89,2 89,1 90,3 90,4 89,6 90,4 89,9 89,6 90,1 89,2 3
5,5 89,5 89,6 88,0 89,5 89,6 88,0 89,5 89,6 88,0 89,5 90,3 89,9 89,7 90,0 89,0 89,6 89,6 88,0
7,5 90,6 90,5 89,0 90,6 90,5 89,0 90,6 90,5 89,0 90,6 91,0 90,2 90,8 90,8 89,6 90,7 90,5 89,0
11 91,8 92,3 91,5 91,8 92,3 91,5 91,8 92,3 91,5 91,8 92,3 91,9 92,2 92,5 91,8 92,3 92,4 91,5
15 92,5 92,4 91,2 92,5 92,4 91,2 92,5 92,4 91,2 92,7 93,3 92,9 93,1 93,3 92,7 92,5 92,4 91,2
18,5 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,2 93,0 92,9 93,3 92,8 92,9 93,1 92,4
22 93,0 92,7 91,3 93,0 92,7 91,3 93,0 92,7 91,3 93,0 93,2 92,4 93,1 93,0 91,9 93,0 92,7 91,3
Manufacturer
Construction
Design
V
in force regarding sorted waste disposal.
20
ESHF, ESHC SERIES
MOTORI TRIFASE PER SERIE SHF 50 Hz, 2 poli (fino a 18,5 kW)
THREE-PHASE MOTORS AT 50 Hz, 2 POLES (up to 18,5 kW)
Efficiency N
manufacture
%
Year of
220 V 230 V 240 V 380 V 400 V 415 V
PN Y 380 V Y 400 V Y 415 V Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,75 82,5 83,1 81,3 82,8 82,7 80,1 82,6 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9
1,1 84,0 84,7 83,4 84,4 84,5 82,5 84,3 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4
1,5 84,6 85,8 85,4 85,5 86,3 85,2 85,9 86,2 84,8 84,6 85,8 84,8 84,6 85,8 84,8 84,6 85,8 84,8
2,2 86,5 87,4 86,8 86,4 86,9 85,7 86,6 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0 86,4 86,7 85,0
from 11/2014
3 88,7 89,5 89,1 89,1 89,5 88,4 89,1 89,1 87,7 88,7 89,1 87,7 88,7 89,1 87,7 88,7 89,1 87,7
4 88,6 89,0 87,6 88,6 89,0 87,6 88,6 89,0 87,6 88,7 89,6 89,1 88,6 89,2 88,3 88,9 89,0 87,6 3
5,5 90,1 89,8 88,0 90,1 89,8 88,0 90,1 89,8 88,0 90,2 90,5 89,5 90,3 90,2 88,8 90,1 89,8 88,0
7,5 90,6 90,5 89,0 90,6 90,5 89,0 90,6 90,5 89,0 90,6 91,0 90,2 90,8 90,8 89,6 90,7 90,5 89,0
11 91,8 92,3 91,5 91,8 92,3 91,5 91,8 92,3 91,5 91,8 92,3 91,9 92,2 92,5 91,8 92,3 92,4 91,5
15 92,5 92,4 91,2 92,5 92,4 91,2 92,5 92,4 91,2 92,7 93,3 92,9 93,1 93,3 92,7 92,5 92,4 91,2
18,5 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,1 92,4 92,6 93,2 93,0 92,9 93,3 92,8 92,9 93,1 92,4
Manufacturer
Construction
Design
V
Y Y Altitude T. amb ATEX
PN 220 V 230 V 240 V 380 V 400 V 415 V 380 V 400 V 415 V 660 V 690 V nN Above Sea min/max
kW IN (A) min-1 Level (m) C
0,75 2,96 2,94 2,96 1,71 1,70 1,71 1,70 1,69 1,70 0,98 0,98 2875 2895
1,1 4,19 4,14 4,16 2,42 2,39 2,40 2,41 2,38 2,38 1,39 1,37 2870 2900
1,5 5,35 5,11 5,04 3,09 2,95 2,91 3,09 2,96 2,91 1,78 1,71 2865 2890
2,2 7,97 7,90 7,98 4,60 4,56 4,61 4,57 4,54 4,57 2,64 2,62 2880 2900
3 10,2 10,0 10,1 5,91 5,79 5,82 5,94 5,83 5,87 3,43 3,37 2895 2920
4 13,3 13,1 13,1 7,69 7,56 7,55 7,70 7,56 7,57 4,45 4,36 2885 2905 1000 -15 / 40 No
5,5 18,9 18,8 18,9 10,9 10,9 10,9 10,7 10,6 10,7 6,20 6,14 2925 2940
7,5 24,8 24,4 24,3 14,3 14,4 14,0 14,4 14,1 14,2 8,32 8,16 2920 2935
11 35,0 33,9 33,0 20,2 19,6 19,1 20,4 19,6 19,2 11,8 11,3 2935 2950
15 47,6 46,1 45,2 27,5 26,6 26,1 27,5 26,6 26,1 15,9 15,3 2940 2950
18,5 58,3 56,7 55,6 33,7 32,7 32,1 34,0 33,0 32,7 19,6 19,0 2940 2950
** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual. ESHF-IE3-mott18-2p50-en_a_te
21
ESHS SERIES (B35 from 30 to 37 kW)
ESHF SERIES (B3 from 22 to 75 kW)
MOTORI TRIFASE PER SERIE SHS-SHF 50 Hz, 2 poli (da 22kW fino a75kW)
THREE-PHASE MOTORS AT 50 Hz, 2 POLES
Efficiency N
manufacture
%
Year of
380 V 400 V 415 V
PN Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
22 93,4 93,2 92,7 93,7 93,3 92,5 93,8 93,3 92,3
from 11/2014
30 94,0 94,0 93,1 94,1 94,0 92,8 94,2 93,9 92,6
37 94,4 94,0 93,5 94,6 94,0 93,3 94,7 93,9 93,1
3
45 94,8 94,9 94,6 95,1 95,1 94,6 95,3 95,2 94,5
55 95,1 95,0 94,9 95,4 95,3 94,9 95,5 95,3 94,8
75 95,4 95,2 94,6 95,6 95,3 94,5 95,7 95,3 94,4
Manufacturer
Construction
Design
Note: Observe the regulations and codes locally in force regarding sorted waste disposal.
22
ESHE SERIES
MOTORI TRIFASE PER SERIE SHE 50 Hz, 4 poli
THREE-PHASE MOTORS AT 50 Hz, 4 POLES
Efficiency N
manufacture
%
Year of
220 V 230 V 240 V 380 V 400 V 415 V
PN Y 380 V Y 400 V Y 415 V Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,25 - - - - - - - - - - - - - - - - - - -
06/2011
0,37 - - - - - - - - - - - - - - - - - - -
0,55 - - - - - - - - - - - - - - - - - - -
0,75 80,4 81,3 79,8 81,1 81,4 79,1 81,4 81,2 78,4 80,4 81,2 78,4 80,4 81,2 78,4 80,4 81,2 78,4 2
1,1 84,9 85,7 84,7 85,3 85,5 83,8 85,3 85 82,7 84,9 85 82,7 84,9 85 82,7 84,9 85 82,7
1,5 86,6 87 85,7 86,7 86,9 84,5 86,4 85,9 83,3 86,4 85,9 83,3 86,4 85,9 83,3 86,4 85,9 83,3
from 11/2014
2,2 87,6 88,6 88,3 88,2 88,8 87,9 88,5 88,7 87,4 87,6 88,6 87,4 87,6 88,6 87,4 87,6 88,6 87,4
3 88,5 89,2 88,5 88,6 88,9 87,6 88,6 88,6 86,8 88,5 88,6 86,8 88,5 88,6 86,8 88,5 88,6 86,8
3
4 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,2 88,9 88,6 89,2 88,4 88,8 89,1 87,9
5,5 90,4 90,9 89,7 90,4 90,9 89,7 90,4 90,9 89,7 90,4 91,0 90,5 90,9 91,1 90,2 90,9 90,9 89,7
7,5 90,4 91,2 90,4 90,4 91,2 90,4 90,4 91,2 90,4 90,4 91,2 91,1 90,7 91,3 90,8 90,9 91,2 90,4
11 91,5 92,2 91,4 91,5 92,2 91,4 91,5 92,2 91,4 91,5 92,4 92,4 91,9 92,5 92,0 91,9 92,2 91,4
Manufacturer
Construction
Design
V
in force regarding sorted waste disposal.
23
ESHS SERIES (B5/B35 from 0,55 to 11 kW)
ESHF SERIES (B3 from 0,25 to 11 kW)
MOTORI TRIFASE PER SERIE ESHS4-ESHF4 50 Hz, 4 poli (fino a 11 kW)
THREE-PHASE MOTORS AT 50 Hz, 4 POLES
Efficiency N
manufacture
%
Year of
220 V 230 V 240 V 380 V 400 V 415 V
PN Y 380 V Y 400 V Y 415 V Y 660 V Y 690 V IE
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,25 - - - - - - - - - - - - - - - - - - -
06/2011
0,37 - - - - - - - - - - - - - - - - - - -
0,55 - - - - - - - - - - - - - - - - - - -
0,75 80,4 81,3 79,8 81,1 81,4 79,1 81,4 81,2 78,4 80,4 81,2 78,4 80,4 81,2 78,4 80,4 81,2 78,4 2
1,1 84,9 85,7 84,7 85,3 85,5 83,8 85,3 85 82,7 84,9 85 82,7 84,9 85 82,7 84,9 85 82,7
1,5 86,6 87 85,7 86,7 86,9 84,5 86,4 85,9 83,3 86,4 85,9 83,3 86,4 85,9 83,3 86,4 85,9 83,3
from 11/2014
2,2 87,6 88,6 88,3 88,2 88,8 87,9 88,5 88,7 87,4 87,6 88,6 87,4 87,6 88,6 87,4 87,6 88,6 87,4
3 88,5 89,2 88,5 88,6 88,9 87,6 88,6 88,6 86,8 88,5 88,6 86,8 88,5 88,6 86,8 88,5 88,6 86,8
3
4 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,2 88,9 88,6 89,2 88,4 88,8 89,1 87,9
5,5 90,4 90,9 89,7 90,4 90,9 89,7 90,4 90,9 89,7 90,4 91,0 90,5 90,9 91,1 90,2 90,9 90,9 89,7
7,5 90,4 91,2 90,4 90,4 91,2 90,4 90,4 91,2 90,4 90,4 91,2 91,1 90,7 91,3 90,8 90,9 91,2 90,4
11 91,5 92,2 91,4 91,5 92,2 91,4 91,5 92,2 91,4 91,5 92,4 92,4 91,9 92,5 92,0 91,9 92,2 91,4
Manufacturer
Construction
Design
V
in force regarding sorted waste disposal.
24
MOTOR NOISE
The tables below show the mean sound pressure levels (Lp) measured at 1 meters distance in a free field according
to the A curve (ISO 1680 standard).
The noise values are measured with idling 50 Hz motor with a tolerance of 3 dB (A).
25
ErP 2009/125/EC
ESH SERIES
PUMPS
Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament and the
Council to adopt specific measures to the purpose of reducing energy consumption and further negative environmental
impacts. Through the Directives 2005/32/EC, energy-using products (EuP), and 2009/125/EC, energy-related products
(ErP) a framework for ecodesign requirements was established.
The Commission Regulation (EU) No 547/2012 has implemented two directives with regard to ecodesign
requirements for some types of clean water pumps placed on the market and put into service inside EU zone
as self-alone units or integrated in other products.
For end-suction close-coupled pumps (ESCC for the Regulation) and end-suction own-bearing pumps (ESOB for the
Regulation) the efficiency assessment refers to:
just the pump and not the pump and motor assembly (electric or combustion);
pumps with just one impeller;
pumps with a nominal pressure PN not higher than 16 bar (1600 kPa);
pumps with a minimum nominal flow not less than 6 m3/h;
pumps with a maximum nominal power at the shaft not higher than 150 kW;
pumps designed to operate at a speed of 2900 min-1 (for electric pumps this means 50 Hz 2-pole electric
motors) and with a head not greater than 140 metres;
pumps designed to operate at a speed of 1450 min-1 (for electric pumps this means 50 Hz 4-pole electric
motors) and with a head not greater than 90 metres;
use with clean water at a temperature ranging from -10C to 120C (the test is performed with cold water at a
temperature not higher than 40C).
According to the definitions established in the Regulation ESHE and ESHS versions correspond to the end-suction
close-coupled pump while ESH, ESHF and ESHC versions correspond to the end-suction own bearing pump.
This regulation states that water pumps shall have a minimum index MEI coming from a dedicated formula which
considers hydraulic efficiency values at best efficiency point (BEP), 75 % of the flow at BEP (Part load PL) and 110
% of the flow at BEP (Over load OL).
26
ESH SERIES
ESH SERIES
MINIMUM EFFICIENCY
MINIMUM INDEX
EFFICIENCY (MEI) (MEI)
INDEX
2-POLE 4-POLE
ESH, ESHE ESH, ESHE
PUMP SIZE ESHS PUMP SIZE ESHS
ESHF, ESHC ESHF
25-125/128 0,40 0,40 25-125/128 0,40 0,40
25-160/160 0,40 0,40 25-160/160 0,40 0,40
25-200/199 0,40 0,40 25-200/199 0,40 0,40
25-250/245 0,40 0,40 25-250/245 0,40 0,40
32-125/128 0,40 0,40 32-125/128 0,40 0,40
32-160/160 0,40 0,40 32-160/160 0,40 0,40
32-200/199 0,40 0,40 32-200/199 0,40 0,40
32-250/245 0,40 0,40 32-250/245 0,40 0,40
40-125/135 0,40 0,40 40-125/135 0,40 0,40
40-160/171 0,40 0,40 40-160/171 0,40 0,40
40-200/209 0,40 0,40 40-200/209 0,40 0,40
40-250/251 0,40 0,40 40-250/251 0,40 0,40
50-125/137 0,40 0,40 50-125/137 0,40 0,40
50-160/174 0,40 0,40 50-160/174 0,40 0,40
50-200/209 0,40 0,40 50-200/209 0,40 0,40
50-250/250 0,40 0,40 50-250/250 0,40 0,40
65-160/176 0,40 0,40 - - -
65-200/215 0,40 0,40 65-200/219 0,40 0,40
65-250/255 0,40 0,40 65-250/255 0,40 0,40
80-160/186 0,40 0,40 80-160/186 0,40 0,40
80-200/226 0,40 0,40 80-200/220 0,40 0,40
80-250/270 0,40 0,40 80-250/270 0,40 0,40
ESH-MEI-en_a_sc
27
ESH SERIES
HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 2 POLES
28
ESH 25, 32, 40, 50 SERIES
HYDRAULIC PERFORMANCE TABLE AT 50 Hz, 2 POLES
PUMP Q = DELIVERY
TYPE F p % T l/s 0 2,0 2,5 3,1 3,6 4,2 4,7 5,3 5,9 6,4 7,0 7,5 8,1
PN m3/h 0 7 9 11 13 15 17 19 21 23 25 27 29
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
25-125/07* 0,75 64,0 114 16,3 14,7 13,8 12,8 11,7 10,5 9,2
25-125/11* 1,1 128 66,1 20,8 19,3 18,6 17,6 16,6 15,4 14,2 12,8
25-160/15* 1,5 61,3 145 26,5 25,2 24,2 22,8 21,3 19,4 17,4 15,1 12,5
25-160/22* 2,2 160 63,2 32,8 31,6 30,7 29,5 28,1 26,4 24,6 22,5 20,2 17,7
25-200/30 3 52,5 182 43,0 39,8 38,3 36,6 34,5 32,1 29,4 26,4 23,0
25-200/40 4 199 54,2 52,2 49,0 47,6 45,9 44,0 41,7 39,3 36,5 33,4 30,1
25-250/55 5,5 47,6 208 57,7 55,9 54,8 53,3 51,5 49,6 47,4 44,7 41,2
25-250/75 7,5 49,2 228 70,5 68,4 67,5 66,2 64,6 62,7 60,6 58,4 55,8 52,7
25-250/110 11 245 50,7 82,6 80,3 79,4 78,2 76,6 74,8 72,8 70,7 68,3 65,7
32-125/07* 0,75 62,2 114 16,1 14,5 13,6 12,5 11,2 9,7 8,1 6,4
32-125/11* 1,1 128 64,4 20,6 19,2 18,4 17,3 16,1 14,8 13,3 11,7 10,0
32-160/15* 1,5 58,3 145 26,9 24,9 23,8 22,3 20,6 18,5 16,2 13,7 11,1
32-160/22* 2,2 160 60,2 33,1 31,3 30,3 29,0 27,5 25,6 23,5 21,2 18,7 16,0
32-200/30 3 50,8 182 43,4 39,2 37,6 35,6 33,3 30,6 27,7 24,4 20,9
32-200/40 4 199 52,5 52,6 48,3 46,8 44,9 42,8 40,3 37,6 34,5 31,2 27,6
32-250/55 5,5 46,1 208 57,5 55,7 55,0 53,9 52,4 50,5 48,3 45,9 43,2
32-250/75 7,5 47,7 228 70,3 67,5 66,5 65,2 63,5 61,5 59,2 56,7 54,0 50,9
32-250/110 11 245 49,2 82,3 79,2 78,3 77,0 75,4 73,6 71,4 69,1 66,5 63,7 60,6 57,2
PUMP Q = DELIVERY
TYPE F p % T l/s 0 5,0 5,8 6,7 7,5 8,3 9,2 10,0 10,8 11,7 12,5 13,3 14,2
PN m3/h 0 18 21 24 27 30 33 36 39 42 45 48 51
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
40-125/11* 1,1 66,6 111 15,7 12,8 11,8 10,7 9,5 8,3 6,9 5,5 4,0
40-125/15* 1,5 68,2 122 19,1 16,4 15,5 14,4 13,3 12,1 10,8 9,4 8,0 6,5
40-125/22* 2,2 135 70,1 23,7 21,1 20,2 19,2 18,1 17,0 15,7 14,4 13,0 11,5 10,1
40-160/30 3 67,5 159 32,1 29,4 28,3 27,0 25,6 24,1 22,5 20,7 18,9 17,0 15,1
40-160/40 4 171 69,5 37,9 35,4 34,4 33,2 31,8 30,2 28,5 26,7 24,8 22,7 20,7 18,6
40-200/55 5,5 65,0 190 49,1 46,3 45,2 43,8 42,2 40,4 38,4 36,1 33,7 31,0 28,1 25,0
40-200/75 7,5 209 66,5 58,2 55,1 53,9 52,4 50,8 49,0 47,0 44,9 42,5 40,0 37,3 34,4
40-250/92 9,2 58,0 218 64,9 62,0 60,9 59,6 58,1 56,2 54,1 51,5 48,4 44,6
40-250/110A 11,0 58,0 218 64,9 62,0 60,9 59,6 58,1 56,2 54,1 51,5 48,4 44,6
40-250/110 11 58,5 233 74,6 71,3 70,3 69,0 67,6 65,9 63,8 61,5 58,6 55,2 51,3
40-250/150 15 251 59,0 87,7 84,0 82,9 81,6 80,1 78,4 76,6 74,4 72,0 69,3 66,1 62,4 58,2
PUMP Q = DELIVERY
TYPE F p % T l/s 0 10 11 12,73 14,09 15,45 16,82 18,18 19,55 20,91 22,27 23,636 25
PN m3/h 0 36 41 46 51 56 61 65 70 75 80 85 90
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
50-125/22* 2,2 72,9 114 16,8 14,3 13,4 12,4 11,2 9,8 8,4 6,9 5,4
50-125/30 3 74,6 125 20,4 18,2 17,4 16,5 15,4 14,2 12,9 11,4 9,9 8,3
50-125/40 4 137 76,5 24,7 22,7 22,0 21,2 20,3 19,2 18,0 16,7 15,3 13,8 12,2
50-160/55 5,5 72,0 158 34,0 30,5 29,5 28,3 26,9 25,5 23,9 22,2 20,4 18,5 16,4
50-160/75 7,5 174 74,0 40,7 37,4 36,3 35,2 33,9 32,6 31,0 29,4 27,6 25,6 23,5 21,1 18,6
50-200/92 9,2 70,0 197 52,9 47,4 45,8 43,8 41,7 39,3 36,7 33,8 30,7 27,4 23,7
50-200/110A 11 70,0 197 52,9 47,4 45,8 43,8 41,7 39,3 36,7 33,8 30,7 27,4 23,7
50-250/110 11 209 72,0 38,5 54,5 37,9 37,3 36,4 35,2 33,6 31,6 29,3 26,5 23,5 27,2
50-250/150 15 69,5 224 70,2 66,6 65,4 64,0 62,4 60,4 58,1 55,3 52,0 48,1
50-250/185 18,5 68,4 237 79,9 74,9 73,6 72,1 70,4 68,4 66,2 63,6 60,7 57,3 53,4
50-250/220 22 250 67,3 88,9 84,5 83,7 82,8 81,9 80,9 79,8
Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)
(1) External diameter of full impeller (2) Hydraulic efficiency of pump (3) External diameter of trimmed impeller. ESH-25-32-40-50_2p50-en_a_th
*Available also in single-phase version.
29
ESH 65, 80 SERIES
TABELLA DI PRESTAZIONI
HYDRAULIC IDRAULICHE
PERFORMANCE SERIE AT
TABLE ESH50
65,Hz,
80 2
2 poli
POLES50 Hz
PUMP Q = DELIVERY
TYPE F p % T l/s 0 13 14,77 16,96 19,15 21,34 23,53 25,72 27,91 30,1 32,29 34,477 37
3
PN m /h 0 45 53 61 69 77 85 93 100 108 116 124 132
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
65-160/40 4 72,1 127 21,1 17,2 15,7 14,1 12,3 10,6 8,7
65-160/55 5,5 73,9 140 25,8 22,5 21,1 19,5 17,8 16,1 14,2 12,3 10,3
65-160/75 7,5 75,7 154 31,5 28,8 27,5 26,0 24,4 22,6 20,8 18,9 16,9 14,9
65-160/92 9,2 73,0 164 36,3 33,8 32,2 30,3 28,2 25,9 23,6 21,4 19,4 17,7
65-160/110A 11 73,0 164 36,3 33,8 32,2 30,3 28,2 25,9 23,6 21,4 19,4 17,7
65-160/110 11 176 74,4 42,1 40,1 38,7 37,0 35,0 32,8 30,5 28,1
65-200/150 15 71,7 192 52,4 50,3 49,2 47,9 46,2 44,3 42,1 39,6 36,8
65-200/185 18,5 72,8 203 59,3 56,4 55,2 53,7 51,9 49,9 47,6 45,0 42,2
65-200/220 22 215 74,0 31,1 30,3 28,4 25,0 20,2 56,1 53,7 51,1 48,2 45,0
65-250/300 30 74,5 240 83,7 81,5 80,2 78,6 76,7 74,4 71,9 69,0 65,8 62,3
65-250/370 37 255 73,5 96,5 94,8 93,3 91,6 89,6 87,3 84,8 82,0 79,0 75,7 72,2
PUMP Q = DELIVERY
TYPE F p % T l/s 0 20 24,24 28,48 32,73 36,97 41,21 45,45 49,7 53,94 58,18 62,424 67
PN m3/h 0 72 87 103 118 133 148 164 179 194 209 225 240
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
80-160/110 11 75,0 169 33,0 31,8 30,3 28,4 26,1 23,5 20,7 17,7 14,6 11,5
80-160/150 15 76,5 177 39,5 38,7 37,2 35,4 33,2 30,7 27,9 24,9 21,7 18,5 15,2
80-160/185 18,5 186 78,0 46,4 45,6 44,1 42,4 40,3 37,9 35,3 32,4 29,3 26,1 22,6
80-200/220 22 80,5 198 51,8 51,4 50,0 48,2 46,2 43,8 41,2 38,4 35,4 32,1 28,6
80-200/300 30 81,0 215 62,3 62,6 61,3 59,7 57,7 55,3 52,6 49,7 46,5 43,1 39,6 36,0
80-200/370 37 226 81,5 69,8 70,8 69,7 68,2 66,4 64,2 61,7 58,9 55,8 52,5 48,9 45,2 41,3
80-250/450 45 79,5 237 82,2 78,7 76,4 73,7 70,5 66,9 63,0 58,6 53,8
80-250/550 55 80,0 252 93,9 91,8 89,6 87,1 84,1 80,7 77,0 72,9 68,5
80-250/750 75 270 78,0 109,6 108,4 106,4 103,9 101,1 97,9 94,3 90,4 86,0 81,2
Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A) ESH-65-80_2p50-en_a_th
(1) External diameter of full impeller (2) Hydraulic efficiency of pump (3) External diameter of trimmed impeller
30
ESH SERIES
HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 4 POLES
31
ESH 25, 32, 40, 50 SERIES
HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 4 POLES
PUMP Q = DELIVERY
TYPE F p % T l/s 0 1,3 1,6 1,9 2,2 2,5 2,8 3,1 3,4 3,7 4,0 4,3 4,6
PN m3/h 0 5 6 7 8 9 10 11 12 13 14 15 17
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
25-125/02A 0,25 58,5 114 4,0 3,5 3,2 2,9 2,6 2,2 1,7
25-125/02 0,25 128 60,8 5,2 4,7 4,4 4,1 3,8 3,4 3,0 2,5
25-160/02A 0,25 57,4 145 6,5 6,0 5,7 5,3 4,8 4,3 3,8 3,2
25-160/02 0,25 160 59,4 8,0 7,5 7,2 6,9 6,5 6,0 5,5 4,9 4,3
25-200/03 0,37 50,4 182 10,4 9,4 8,9 8,4 7,8 7,1 6,3 5,5 4,6 3,6
25-200/05 0,55 199 52,2 12,5 11,6 11,1 10,6 10,0 9,4 8,7 7,9 7,0 6,1 5,1
25-250/07 0,75 46,8 208 14,4 13,6 13,3 12,9 12,5 11,9 11,3 10,5 9,8 8,9 8,1
25-250/11 1,1 48,4 228 17,5 16,7 16,4 16,1 15,7 15,1 14,6 13,9 13,2 12,4 11,5 10,7
25-250/15 1,5 245 49,7 20,4 19,6 19,3 19,0 18,6 18,1 17,6 17,0 16,3 15,5 14,7 13,9 13,0
32-125/02A 0,25 59,9 114 4,0 3,6 3,4 3,1 2,8 2,4 2,0 1,5
32-125/02 0,25 128 62,3 5,2 4,8 4,6 4,3 4,0 3,6 3,3 2,8 2,4 1,9
32-160/02A 0,25 58,0 145 6,6 6,0 5,7 5,3 4,8 4,2 3,6 2,9
32-160/02 0,25 160 60,0 8,1 7,5 7,2 6,9 6,4 5,9 5,4 4,7 4,0 3,3 2,5
32-200/03 0,37 49,9 182 10,5 9,4 8,9 8,4 7,7 7,0 6,2 5,3 4,3 3,2
32-200/05 0,55 199 51,6 12,7 11,6 11,2 10,6 10,0 9,3 8,5 7,7 6,8 5,8 4,7
32-250/07 0,75 44,0 208 14,2 13,5 13,2 12,8 12,3 11,7 11,0 10,2 9,3 8,3 7,1
32-250/11 1,1 45,6 228 17,4 16,6 16,3 15,9 15,5 14,9 14,3 13,6 12,8 11,9 10,9 9,8
32-250/15 1,5 245 46,9 20,3 19,5 19,2 18,9 18,4 17,9 17,3 16,7 15,9 15,1 14,2 13,2 12,2
PUMP Q = DELIVERY
TYPE F p % T l/s 0 2,5 2,9 3,4 3,8 4,2 4,6 5,1 5,5 5,9 6,4 6,8 7,2
3
PN m /h 0 9 11 12 14 15 17 18 20 21 23 24 26
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
40-125/02A 0,25 66,2 122 4,5 3,7 3,4 3,2 2,9 2,6 2,2
40-125/02 0,25 135 68,2 5,6 4,8 4,5 4,3 4,0 3,7 3,4 3,0 2,7 2,3 2,0
40-160/03 0,37 67,6 159 8,0 7,2 6,9 6,6 6,3 5,9 5,5 5,0 4,6 4,1 3,5
40-160/05 0,55 171 66,5 9,2 8,5 8,2 7,9 7,6 7,2 6,8 6,3 5,8 5,3 4,8 4,2
40-200/07 0,75 64,3 190 11,9 11,2 10,9 10,5 10,1 9,6 9,1 8,5 7,8 7,1 6,4
40-200/11 1,1 209 62,9 14,2 13,3 13,0 12,6 12,2 11,8 11,2 10,7 10,0 9,3 8,6 7,7
40-250/11 1,1 55,8 218 15,6 14,6 14,3 13,9 13,5 13,0 12,4 11,7 11,0 10,1
40-250/15 1,5 57,0 233 18,1 17,0 16,7 16,3 15,9 15,5 14,9 14,3 13,7 12,9 12,1
40-250/22 2,2 251 58,1 21,5 20,4 20,0 19,6 19,2 18,7 18,2 17,6 16,9 16,2 15,4 14,6 13,6
PUMP Q = DELIVERY
TYPE F p % T l/s 0 5 6 6,364 7,045 7,727 8,409 9,091 9,773 10,45 11,14 11,818 12,5
PN m3/h 0 18 20 23 25 28 30 33 35 38 40 43 45
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
50-125/02 0,25 71,5 114 4,1 3,4 3,1 2,9 2,6 2,3 2,0 1,7 1,3 0,9
50-125/03 0,37 73,2 125 5,0 4,3 4,1 3,9 3,6 3,3 3,0 2,7 2,3 2,0 1,6
50-125/05 0,55 137 75,1 6,0 5,4 5,2 5,0 4,8 4,5 4,2 3,9 3,6 3,2 2,9 2,5 2,1
50-160/07 0,75 71,3 158 8,2 7,3 7,1 6,8 6,5 6,2 5,8 5,5 5,1 4,6 4,2
50-160/11 1,1 174 73,0 9,8 8,8 8,6 8,3 8,0 7,7 7,4 7,0 6,7 6,3 5,8 5,3 4,8
50-200/11 1,1 69,1 197 12,8 11,2 10,7 10,2 9,7 9,1 8,5 7,8 7,1 6,3 5,5
50-200/15 1,5 209 70,1 14,7 13,0 12,6 12,1 11,5 10,9 10,3 9,6 8,9 8,1 7,3 6,4 5,5
50-250/22A 2,2 70,0 224 38,5 16,0 37,9 37,3 36,4 35,2 33,6 31,6 29,3 26,5 23,5
50/250/22 2,2 69,0 237 19,4 17,8 17,4 17,0 16,5 16,0 15,4 14,8 14,0 13,2 12,3 11,3
50-250/30 3 250 67,9 21,9 20,6 20,2 19,8 19,4 18,8 18,3 17,6 17,0 16,2 15,4 14,5 13,5
Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A) ESH-25-32-40-50_4p50-en_a_th
(1) Diametro esterno girante piena (2) Efficienza idraulica della pompa (3) Diametro esterno girante ridotta (tornita).
32
ESH 65, 80 SERIES
TABELLA DI PRESTAZIONI
HYDRAULIC IDRAULICHE
PERFORMANCE SERIE ESH
RANGE 65, 80
AT 50 Hz,44poli 50 Hz
POLES
PUMP Q = DELIVERY
TYPE F p % T l/s 0 8 8,788 10,08 11,36 12,65 13,94 15,23 16,52 17,8 19,09 20,379 22
3
PN m /h 0 27 32 36 41 46 50 55 59 64 69 73 78
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
65-200/15 1,5 68,2 176 10,7 9,8 9,3 8,7 8,1 7,3 6,3 5,3 4,0
65-200/22 2,2 70,2 199 13,8 13,1 12,7 12,2 11,6 11,0 10,2 9,3 8,4 7,3
65-200/30 3 219 72,0 16,9 16,3 15,9 15,5 15,0 14,4 13,8 13,0 12,1 11,2 10,2
65-250/40 4 71,9 240 20,4 19,3 18,8 18,3 17,6 16,9 16,1 15,2 14,2 13,0
65-250/55 5,5 255 71,0 23,7 23,1 22,6 22,0 21,4 20,7 19,9 19,1 18,1 17,1 16,0 14,7
PUMP Q = DELIVERY
TYPE F p % T l/s 0 10 12,73 15,45 18,18 20,91 23,64 26,36 29,09 31,82 34,55 37,273 40
PN m3/h 0 36 46 56 65 75 85 95 105 115 124 134 144
kW (1) (2) (3) H = TOTAL HEAD METRES COLUMN OF WATER
80-160/15 1,5 75,2 169 8,0 7,6 7,0 6,3 5,6 4,8 4,0 3,1
80-160/22A 2,2 74,2 177 9,4 9,0 8,5 7,8 7,1 6,3 5,4 4,5 3,5
80-160/22 2,2 186 73,4 10,8 10,4 9,9 9,2 8,5 7,7 6,8 5,9 4,9
80-200/30 3 80,5 198 12,3 11,9 11,2 10,4 9,5 8,5 7,5 6,4 5,3
80-200/40 4 220,0 78,3 15,4 15,3 14,7 13,9 13,0 12,1 11,1 10,1 9,0 7,9
80-250/55 5,5 77,5 237 20,3 19,5 19,2 18,9 18,5 18,1 17,6 17,2 16,6
80-250/75 7,5 76,7 252 23,1 22,2 21,9 21,6 21,3 20,9 20,5 20,1 19,7
80-250/110 11 270 74,3 26,6 26,1 25,8 25,5 25,2 24,8 24,5 24,1 23,6
Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A) ESH-65-80_4p50_a_th
(1) External diameter of full impeller (2) Hydraulic efficiency of pump (3) External diameter of trimmed impeller.
33
ESH SERIES
IDENTIFICATION OF IMPELLER TYPOLOGY
[%]
[%]
04940_B_SC
34
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
0 10 20 30 40 50 60 70 80 90 gpm]
Q [Imp
70
20 55
57
59
61
63 60
65
15 66.1 50
65
40
H [ft]
H[m]
25-125/11
128
10 64.0
30
25-125/07
114 20
5
10
0 0
2
6
NPSH [ft]
NPSH[m]
4
1
25-125/11
128 2
0 0
1.5 2
2
1.0 25-125/11
128
Pp[kW]
1
PP[HP]
25-125/07
0.5 114
1
ESH25-125_2P50_A_CH
0.0 0
0 5 10 15 20 Q25
[m3/h]
0 1 2 3 4 5 6 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
35
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
63.2
25 80
61.3
20 60.5
58 60
H [ft]
H[m]
15 25-160/22
160
40
10 25-160/15
145
20
5
0 0
4
3 10
NPSH [ft]
NPSH[m]
2
25-160/22 5
160
1
0 0
2.5
3.0
2.0
25-160/22 2.5
160
1.5 2.0
Pp[kW]
25-160/15
PP[HP]
145 1.5
1.0
1.0
0.5
0.5
ESH25-160_2P50_A_CH
0.0 0.0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
36
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
120
52.5
52
30 50 100
H [ft]
H[m]
25-200/40 80
199
20
60
25-200/30
182
40
10
20
0 0
5
15
4
NPSH [ft]
NPSH[m]
3 10
25-200/40
2 199
5
1
0 0
5
6
4
25-200/40 5
199
3 4
Pp[kW]
25-200/30
PP[HP]
182 3
2
2
1
1
ESH25-200_2P50_A_CH
0 0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
37
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
70
50.7
60 25-250/110 200
49.2
245
50 47.6
25-250/75
150
228
H [ft]
H[m]
40
25-250/55
208 100
30
20
50
10
0 0
30
8 25-250/110
245
NPSH [ft]
NPSH[m]
20
4
10
0 0
10
12
25-250/110
8 245 10
25-250/75
6 228 8
Pp[kW]
25-250/55
PP[HP]
208 6
4
4
2
2
ESH25-250_2P50_A_CH
0 0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
38
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
0 10 20 30 40 50 60 70 80 90 gpm]
Q [Imp
49
70
51.5
20 54
56.5
59
61.5
60
64.4
15 50
61.5
40
H [ft]
H[m]
59
62.2
56.5
10
30
32-125/11
128
20
5
32-125/07
114 10
0 0
2
6
NPSH [ft]
NPSH[m]
4
1 32-125/11
128
2
0 0
1.5 2.0
1.5
1.0 32-125/11
Pp[kW]
128
1.0
PP[HP]
32-125/07
0.5 114
0.5
ESH32-125_2P50_A_CH
0.0 0.0
0 5 10 15 20 Q25
[m3/h]
0 1 2 3 4 5 6 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
39
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
60.2
25 80
58.3
20 57.5
55 60
52.5
H [ft]
H[m]
15 50
47.5
40
32-160/22
10 160
32-160/15
145
20
5
0 0
4
3 10
NPSH [ft]
NPSH[m]
32-160/22
2 160
5
1
0 0
2.5
3.0
2.0
32-160/22 2.5
160
1.5 2.0
Pp[kW]
32-160/15
PP[HP]
145 1.5
1.0
1.0
0.5
0.5
ESH32-160_2P50_A_CH
0.0 0.0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
40
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
140
40 52.5
120
50.8
50
30 47.5 100
H [ft]
H[m]
45
80
32-200/40
20 199
60
32-200/30
182 40
10
20
0 0
5
15
4
NPSH [ft]
NPSH[m]
3 32-200/40 10
199
2
5
1
0 0
5
6
4
32-200/40
5
199
3 4
Pp[kW]
32-200/30
PP[HP]
182 3
2
2
1
1
ESH32-200_2P50_A_CH
0 0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
41
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
34 36.5
[%]
80 39
41.5
44 250
46.5
70
49.2
60 200
47.7
32-250/110
50 245
46.1
32-250/75 150
H [ft]
H[m]
40 228
32-250/55
208
30 100
20
50
10
0 0
12
32-250/110
245
30
8
NPSH [ft]
NPSH[m]
20
4
10
0 0
10
12
32-250/110
8 245 10
32-250/75
6 228 8
Pp[kW]
PP[HP]
32-250/55 6
4 208
4
2
2
ESH32-250_2P50_A_CH
0 0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
42
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
15 50
68.2
68 66
64
40
H [ft]
62
H[m]
60
66.6
10
30
40-125/22
135
20
40-125/15
5
122
40-125/11 10
111
0 0
3
8
2
NPSH [ft]
NPSH[m]
40-125/22 6
135
4
1
2
0 0
3 4
3
2
40-125/22
Pp[kW]
135
2
PP[HP]
40-125/15
122
1
40-125/11
1
111
ESH40-125_2P50_A_CH
0 0
0 10 20 30 40 Q50
[m3/h]
0 2 4 6 8 10 12 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
43
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
120
[%]
63
65
67
69
30 100
69.5
69
67.5
67
80
65
20 63
40-160/40
H [ft]
60
H[m]
171
40-160/30
159
40
10
20
0 0
6
15
4 40-160/40
NPSH [ft]
NPSH[m]
171
10
2
5
0 0
5
6
4 40-160/40
171 5
3 40-160/30 4
Pp[kW]
159
PP[HP]
3
2
2
1
1
ESH40-160_2P50_A_CH
0 0
0 10 20 30 40 50 Q60
[m3/h]
0 2 4 6 8 10 12 14 16 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
44
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
180
[%]
60
62
50 64
160
65.0
140
64
40 65
66
62 120
66.5
60
66
30 65 40-200/75 100
209
H [ft]
H[m]
40-200/55 80
190
20
60
40
10
20
0 0
8
40-200/75
6 209 20
NPSH [ft]
NPSH[m]
4
10
2
0 0
8
40-200/75 10
209
6 40-200/55
40-200/55 8
190
190
6
Pp[kW]
4
PP[HP]
4
2
2
ESH40-200_2P50_A_CH
0 0
0 10 20 30 40 50 Q60
[m3/h]
0 2 4 6 8 10 12 14 16 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
45
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
60
58.5
40-250/150 200
251
59.0
50 40-250/110
233 150
H [ft]
H[m]
40 40-250/**
218
30 100
20
50
10
0 0
8
40-250/**
6 218 20
40-250/150
NPSH [ft]
NPSH[m]
251
4
10
2
0 0
16
40-250/150 20
14 251
12 40-250/110
15
233
10
40-250/**
Pp[kW]
8 218
PP[HP]
10
6
4 5
ESH40-250_2P50_A_CH
2
0 0
0 10 20 30 40 50 Q60
[m3/h]
0 2 4 6 8 10 12 14 16 Q [l/s]
**= 9.2 kW (/92) ESHE, **= 11 kW (/110A) ESHS, ESHF, ESHC
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
46
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
60
75
72.5
15 74.6
50
70
67.5
72.9 65 40
H [ft]
H[m]
62.5
10
50-125/40 30
137
50-125/30 20
125
5
50-125/22
114 10
0 0
5
15
4
NPSH [ft]
NPSH[m]
3 10
50-125/40
2 137
5
1
0 0
5
6
4
50-125/40 5
137
3 4
Pp[kW]
50-125/30
PP[HP]
125 3
2
50-125/22
114 2
1
1
ESH50-125_2P50_A_CH
0 0
0 10 20 30 40 50 60 70 80 Q90
[m3/h]
0 5 10 15 20 Q [l/s]
25
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
47
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
74
30 100
72
72
70
25 80
H [ft]
68
H[m]
66
64
20
60
50-160/75
15 174
50-160/55
40
10 158
20
5
0 0
8
50-160/55
6 158 20
50-160/75
NPSH [ft]
NPSH[m]
174
4
10
2
0 0
8
10
7
50-160/75
6 174 8
5 50-160/55
6
Pp[kW]
158
4
PP[HP]
3 4
2
2
ESH50-160_2P50_A_CH
1
0 0
0 10 20 30 40 50 60 70 80 90 Q100
[m3/h]
0 5 10 15 20 25 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
48
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
60 200
62
64 66
68
70
50 72.0
150
40 70
70.0 68
H[m]
H [ft]
66
64
30 62 100
50-200/110
209
20
50-200/**
197 50
10
0 0
8
50-200/**
197 50-200/110
6 209
20
NPSH [ft]
NPSH[m]
4
10
2
0 0
12 16
50-200/110
209 14
10
50-200/** 12
8 197
10
Pp[kW]
6 8
PP[HP]
6
4
4
2
ESH50-200_2P50_A_CH
2
0 0
0 20 40 60 80 Q100
[m3/h]
0 5 10 15 20 25 Q [l/s]
**= 9.2 kW (/92) ESHE, **= 11 kW (/110A) ESHS, ESHF, ESHC
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
49
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
300
[%]
90
60
62
64
80 66
67.3
250
70
66
64
60 68.4 200
68
50-250/220
69.5 250
50
68 50-250/185
H [ft]
150
H[m]
237
40 50-250/150
224
30 100
20
50
10
0 0
6 50-250/150
224 50-250/220
250 15
4
NPSH [ft]
NPSH[m]
10
2
5
0 0
24
50-250/220 30
20 250
50-250/185
25
16 237
20
Pp[kW]
50-250/150
12
PP[HP]
224 15
8 10
4 5
ESH50-250_2P50_A_CH
0 0
0 10 20 30 40 50 60 70 80 90 Q100
[m3/h]
0 5 10 15 20 25 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
50
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
72
32 73.0
100
28 68
75.7 65-160/110
176
24 80
73.9
H [ft]
20
H[m]
64 65-160/**
72.1 164 60
16
65-160/75
12 154 40
8 65-160/55
65-160/40
140 20
4 127
0 0
8
6 20
NPSH [ft]
NPSH[m]
4
10
2
0 0
15 20
65-160/110
176
65-160/** 15
10 164
Pp[kW]
65-160/75
10
PP[HP]
154
5 65-160/55
65-160/40
140 5
127
ESH65-160_2P50_A_CH
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q150
[m3/h]
0 5 10 15 20 25 30 35 40 Q [l/s]
**= 9.2 kW (/92) ESHE **= 11 kW (/110A) ESHS, ESHF, ESHC
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
51
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
72.8 72.5
50
70
150
65-200/220
71.7 215
40
65-200/185
203
H [ft]
H[m]
65-200/150
30 192
100
20
50
10
0 0
8
65-200/220
6 215 20
NPSH [ft]
NPSH[m]
4
10
2
0 0
25
65-200/220 30
215
20
65-200/185 25
203
15 65-200/150 20
Pp[kW]
192
PP[HP]
15
10
10
5
5
ESH65-200_2P50_A_CH
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q150
[m3/h]
0 5 10 15 20 25 30 35 40 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
52
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
65-250/370
60 255 200
H [ft]
H[m]
65-250/300
240
150
40
100
20
50
0 0
10
65-250/300 30
240
8
65-250/370
NPSH [ft]
NPSH[m]
6 20
255
4
10
2
0 0
40
50
65-250/370
255
30 40
65-250/300
240
30
Pp[kW]
20
PP[HP]
20
10
10
ESH65-250_2P50_A_CH
0 0
0 20 40 60 80 100 120 140 Q [m3/h]
0 5 10 15 20 25 30 35 40 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
53
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
0 100 200 300 400 500 600 700 800 900 gpm]
Q [Imp
H [ft]
H[m]
75.0
68
20
80-160/185 60
15 186
80-160/150 40
10 177
80-160/110
169x15 20
5
0 0
8
80-160/110
6 169x15 20
80-160/185
NPSH [ft]
NPSH[m]
186
4
10
2
0 0
20
25
80-160/185
15 186 20
80-160/150
15
Pp[kW]
177
10
PP[HP]
80-160/110
169x15 10
5
5
ESH80-160_2P50_A_CH
0 0
0 50 100 150 200 250
Q [m3/h]
0 10 20 30 40 50 60 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
54
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
50 78
81.0
75 150
40 80-200/370
80.5
H [ft]
H[m]
226
80-200/300
30 100
215
80-200/220
20 198
50
10
0 0
8
80-200/220 80-200/370
6 198
20
226
NPSH [ft]
NPSH[m]
4
10
2
0 0
40
80-200/370 50
35 226
30 80-200/300 40
215
25 80-200/220
30
Pp[kW]
198
20
PP[HP]
15 20
10
10
ESH80-200_2P50_A_CH
5
0 0
0 50 100 150 200 250 Q300
[m3/h]
0 10 20 30 40 50 60 70 80 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
55
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 2 POLES
80
80-250/750 250
79.5
78 270
80-250/550
60 252 200
78
H [ft]
H[m]
80-250/450
237
150
40
100
20
50
0 0
8
80-250/750 20
6
270
NPSH [ft]
NPSH[m]
4
10
2
0 0
80
80-250/750 100
270
60 80
80-250/550
252
60
Pp[kW]
40 80-250/450
PP[HP]
237
40
20
20
ESH80-250_2P50_A_CH
0 0
0 40 80 120 160 200 240 Q280
[m3/h]
0 10 20 30 40 50 60 70 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
56
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 5 10 15 20 25 30 35 40 Q [Imp gpm]
0 10 20 30 40 Q [US gpm] 50
6
18
5 48 50
52
54 16
56
58 [%]
14
4 60.8
12
3 58.5 58 10
56
H [ft]
H[m]
54
8
25-125/02
2
128 6
4
1 25-125/02A
114
2
0 0
1.0
3
25-125/02
NPSH [ft]
NPSH[m]
128 2
0.5
1
0.0 0
0.2
0.2
25-125/02
Pp[kW]
128
0.1
PP[HP]
25-125/02A 0.1
114
ESH25-125_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 Q12
[m3/h]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
57
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 gpm]
Q [Imp
0 10 20 30 40 50 Q60
[US gpm]
10
9 30
8
53 54 [%] 25
55 56
7 57 58
6 59.4 20
5 58
57.4 57
56
H [ft]
15
H[m]
55
54
4 53
25-160/02
3 160 10
25-160/02A
2
145
5
1
0 0
1.0
3
NPSH [ft]
NPSH[m]
2
0.5
1
25-160/02
160
0.0 0
0.4
0.5
0.3 0.4
0.3
Pp[kW]
25-160/02
0.2
PP[HP]
160
25-160/02A 0.2
145
0.1
0.1
ESH25-160_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 Q14
[m3/h]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
58
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 Q [Imp gpm]
0 10 20 30 40 50 60 70 gpm]
Q [US
14
45
12 42 40
44
46 [%]
48
50 35
51
10
52.2 30
8 51
50 25
48
50.4
H [ft]
H[m]
46
6 20
44
42
25-200/05 15
4 199
10
25-200/03
2 182
5
0 0
2.0
6
1.6
NPSH [ft]
NPSH[m]
1.2 4
0.8
25-200/05 2
0.4 199
0.0 0
0.5
0.6
25-200/05
0.4 199
0.5
182
PP[HP]
0.3
0.2
0.2
0.1
0.1
ESH25-200_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 14 Q16
[m3/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
59
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 60 Q [Imp gpm]
0 10 20 30 40 50 60 70 Q [US gpm]
22
70
20 38 40
42
44
18
46
[%] 60
48.5
16 49.7
50
14 48.4
12 25-250/15
40
46.8
245
46
H [ft]
10
H[m]
25-250/11 30
8 228
25-250/07
6 208
20
4
10
2
0 0
5
15
4
NPSH [ft]
NPSH[m]
3 10
2 25-250/15
245 5
1
0 0
1.4
1.2
25-250/15 1.5
1.0 245
25-250/11
0.8
Pp[kW]
228 1.0
PP[HP]
0.6 25-250/07
208
0.4 0.5
0.2
ESH25-250_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 14 16 Q18
[m3/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
5.0
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
60
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 gpm]
Q [Imp
0 10 20 30 40 50 Q60
[US gpm]
6
18
48 50
5 52 54
56
16
59
[%]
14
4 62.3
12
3 59.9 59 10
H [ft]
56
H[m]
54
52 8
50
2 48
6
32-125/02
128 4
1
32-125/02A
114 2
0 0
1.0
3
0.8
NPSH [ft]
NPSH[m]
0.6 2
0.4
32-125/02 1
0.2 128
0.0 0
0.2
0.2
Pp[kW]
PP[HP]
32-125/02
128
0.1
32-125/02A
114
0.1
ESH32-160_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 Q14
[m3/h]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
61
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 Q [Imp gpm]
0 10 20 30 40 50 60 70 gpm]
Q [US
10
9 30
8 45 47.5
50
52.5 25
55 [%]
57.5
7
60.0
6 20
5 58.0 57.5
H [ft]
55 15
H[m]
52.5
4 50
47.5
3 45 10
2 32-160/02A
145 32-160/02 5
160
1
0 0
2
6
NPSH [ft]
NPSH[m]
4
1
32-160/02
160 2
0 0
0.4
0.5
0.3 0.4
0.3
Pp[kW]
0.2 32-160/02
PP[HP]
160
32-160/02A 0.2
145
0.1
0.1
ESH32-160_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 14 Q16
[m3/h]
0 1 1 2 2 3 3 4 4 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
62
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 Q [Imp gpm]
0 10 20 30 40 50 60 70 gpm]
Q [US
14
45
37.5
12 40 40
42.5
45 [%]
47.5
50 35
10
51.6
30
8 50
25
47.5
49.9
H [ft]
45
H[m]
6 42.5 20
40
37.5
15
4
32-200/05
199 10
32-200/03
2 182
5
0 0
2.0
6
1.6
NPSH [ft]
NPSH[m]
1.2 4
32-200/05
0.8 199
2
0.4
0.0 0
0.5
32-200/05
0.6
0.4 199
0.5
182
PP[HP]
0.3
0.2
0.2
0.1
0.1
ESH32-200_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 14 Q16
[m3/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
63
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 60 Q [Imp gpm]
0 10 20 30 40 50 60 70 Q [US gpm]
22
70
20 31.5 34
36.5 39
41.5
18 44
[%] 60
16 47.0
50
14 45.6
44
12 40
43.9
32-250/15
H [ft]
10
H[m]
245
30
8 32-250/11
228
6 20
32-250/07
208
4
10
2
0 0
5
15
4
NPSH [ft]
NPSH[m]
3 10
2 32-250/15
245 5
1
0 0
1.4
1.0
PP[HP]
32-250/07
0.6 208
0.4 0.5
0.2
ESH32-250_4P50_A_CH
0.0 0.0
0 2 4 6 8 10 12 14 16 Q18
[m3/h]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [l/s]
5.0
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
64
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
0 10 20 30 40 50 60 70 80 90 gpm]
Q [Imp
18
57
59
5 61
63 [%] 16
65
67
14
4 68.2
12
66.2
65
3 63
10
H [ft]
H[m]
61
59
8
57
2
6
40-125/02
135 4
1 40-125/02A
122
2
0 0
1.0
3
0.8
NPSH [ft]
NPSH[m]
0.6 40-125/02 2
135
0.4
1
0.2
0.0 0
0.3 0.4
0.3
0.2 40-125/02
135
Pp[kW]
0.2
PP[HP]
40-125/02A
122
0.1
0.1
ESH40-125_4P50_A_CH
0.0 0.0
0 5 10 15 20 Q25
[m3/h]
0 1 2 3 4 5 6 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
65
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
30
[%]
58
60
8 64
66
25
66.5
66
6 67.6 20
64
60
H [ft]
15
H[m]
58
40-160/05
4 171
40-160/03
40-160/03
159 10
159
2
5
0 0
3
40-160/05 8
2 171
NPSH [ft]
NPSH[m]
6
4
1
2
0 0
0.6 0.8
0.5 40-160/05
171
0.6
0.4 40-160/03
159
Pp[kW]
0.3 0.4
PP[HP]
0.2
0.2
0.1
ESH40-160_4P50_A_CH
0.0 0.0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
66
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
H [ft]
H[m]
6 40-200/07 20
190
5
15
4
3 10
2
5
1
0 0
3
40-200/11 8
2 209
NPSH [ft]
NPSH[m]
6
4
1
2
0 0
1.0
40-200/11
209 1.2
0.8
40-200/07
1.0
190
0.6 0.8
Pp[kW]
PP[HP]
0.6
0.4
0.4
0.2
0.2
ESH40-200_4P50_A_CH
0.0 0.0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
67
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
18 57 60
58.1
16
57 50
57.0
14 40-250/22
251
55.8 55
12 40-250/15
40
233
H [ft]
10
H[m]
40-250/11
218 30
8
6 20
4
10
2
0 0
8
40-250/11 40-250/22
218 251
6 20
NPSH [ft]
NPSH[m]
4
10
2
0 0
2.0
40-250/22
2.5
251
1.5 40-250/15 2.0
233
40-250/11
1.5
Pp[kW]
1.0 218
PP[HP]
1.0
0.5
0.5
ESH40-250_4P50_A_CH
0.0 0.0
0 5 10 15 20 25 Q30
[m3/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
68
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
4.0
73.2 72.5
3.5 70
71.5 67.5
10
H [ft]
3.0
H[m]
65
62.5
2.5 60
2.0 50-125/05
137
1.5 5
50-125/03
1.0 125
0.5 50-125/02
114
0.0 0
4
3 10
NPSH [ft]
NPSH[m]
2
50-125/05
137
5
1
0 0
0.6 0.8
0.5
0.6
0.4 50-125/05
137
Pp[kW]
0.3 0.4
PP[HP]
50-125/03
125
0.2 50-125/02
114 0.2
0.1
ESH50-125_4P50_A_CH
0.0 0.0
0 5 10 15 20 25 30 35 40 45 Q50
[m3/h]
0 2 4 6 8 10 12 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
69
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
30
[%]
9 65
68
69
70
71
8
73.0
25
7
71
6
71.3 70 20
69
68
5 65
H [ft]
15
H[m]
50-160/11
4
174
3 50-160/07 10
158
2
5
1
0 0
3 50-160/07
158 8
50-160/11
2 174
NPSH [ft]
NPSH[m]
6
4
1
2
0 0
1.0
1.2
0.8 50-160/11
174 1.0
158
PP[HP]
0.6
0.4
0.4
0.2
0.2
ESH50-160_4P50_A_CH
0.0 0.0
0 10 20 30 40 Q50
[m3/h]
0 2 4 6 8 10 12 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
70
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
H [ft]
H[m]
55
6 20
5 50-200/15
209 15
4
50-200/11
3 197 10
2
5
1
0 0
5
50-200/11 15
4 197
NPSH [ft]
NPSH[m]
3 50-200/15 10
209
2
5
1
0 0
1.5 2.0
50-200/15
209
1.5
1.0
50-200/11
Pp[kW]
197
1.0
PP[HP]
0.5
0.5
ESH50-200_4P50_A_CH
0.0 0.0
0 5 10 15 20 25 30 35 40 45 Q50
[m3/h]
0 2 4 6 8 10 12 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
71
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
67.9 60
15 69.0 66 50
68
70.0 50-250/30 40
H [ft]
H[m]
250
68
10 50-250/22
237 30
50-250/22A
224
20
5
10
0 0
6
50-250/22A
224
15
4
NPSH [ft]
NPSH[m]
50-250/30
250 10
2
5
0 0
3 4
50-250/30
250 3
2 50-250/22
Pp[kW]
237
2
PP[HP]
50-250/22A
224
1
1
ESH50-250_4P50_A_CH
0 0
0 10 20 30 40 Q50
[m3/h]
0 2 4 6 8 10 12 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
72
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
H [ft]
H[m]
8 219
6 65-200/22 20
199
4
65-200/15
176 10
2
0 0
7
6 20
5 65-200/30 15
NPSH [ft]
NPSH[m]
4 219
3 10
2
5
1
0 0
3.2
4
65-200/30
2.4 219
3
Pp[kW]
PP[HP]
65-200/22
1.6 199
2
65-200/15
176
0.8 1
ESH65-200_4P50_A_CH
0.0 0
0 10 20 30 40 50 60 70 Q80
[m3/h]
0 5 10 15 20 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
73
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
68
60
71.9
71 66
64
15 50
71
65-250/55
255
40
H [ft]
H[m]
65-250/40
10 240
30
20
5
10
0 0
6
65-250/40 65-250/55
240 255 15
4
NPSH [ft]
NPSH[m]
10
2
5
0 0
6 8
65-250/55
5
255
6
4 65-250/40
240
Pp[kW]
3 4
PP[HP]
2
2
1
ESH65-250_4P50_A_CH
0 0
0 10 20 30 40 50 60 70 80 Q90
[m3/h]
0 5 10 15 20 Q [l/s]
25
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
74
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
73.4 30
8 72
25
70
74.2 68
74
6 66 20
H [ft]
H[m]
75.2
74 15
4 80-160/22
186
10
80-160/22A
177
2 80-160/15
169x15 5
0 0
3
80-160/15 80-160/22
169x15 186 8
2
NPSH [ft]
NPSH[m]
6
4
1
2
0 0
2.5
3.0
80-160/22
2.0 186
2.5
80-160/22A
1.5 177 2.0
Pp[kW]
80-160/15
PP[HP]
169x15 1.5
1.0
1.0
0.5
0.5
ESH80-160_4P50_A_CH
0.0 0.0
0 20 40 60 80 100 120 Q140
[m3/h]
0 5 10 15 20 25 30 35 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
75
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
H [ft]
H[m]
8
65
6 80-200/40 20
220
4 80-200/30
198 10
2
0 0
8
6 20
80-200/30
NPSH [ft]
NPSH[m]
198
4 80-200/40
220 10
2
0 0
5
6
4 80-200/40
220 5
3 4
Pp[kW]
80-200/30
PP[HP]
198 3
2
2
1
1
ESH80-200_4P50_A_CH
0 0
0 20 40 60 80 100 120 140 Q160
[m3/h]
0 5 10 15 20 25 30 35 40 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
76
ESH SERIES
OPERATING CHARACTERISTICS AT 50 Hz, 4 POLES
73
70
20
76.7 70 60
76 67
15 77.5 64 50
H [ft]
H[m]
76
80-250/110
270 40
10 80-250/75
252 30
80-250/55
237 20
5
10
0 0
8
6 20
NPSH [ft]
NPSH[m]
80-250/110
4 270
10
2
0 0
10
12
8 80-250/110
270 10
6 80-250/75 8
Pp[kW]
252
PP[HP]
80-250/55 6
4 237
4
2
2
ESH80-250_4P50_A_CH
0 0
0 20 40 60 80 100 120 140 Q160
[m3/h]
0 5 10 15 20 25 30 35 40 Q [l/s]
The NPSH values are laboratory values; for practical use we suggest increasing these values by 0,5 m.
These performances are valid for liquids with density = 1,0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.
77
78
DIMENSIONS
AND WEIGHTS
79
ESHE SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES
80
ESHE SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHE 2 poli
WEIGHTS AT 5050 Hz
Hz, 2 POLES
PUMP TYPE DIMENSIONS (mm) WEIGHT
81
ESHE SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES
82
ESHE SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHE 4 poli
WEIGHTS AT 5050 Hz
Hz, 4 POLES
PUMP TYPE DIMENSIONS (mm) WEIGHT
83
ESHS SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES
84
ESHS SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHS 2 poli
WEIGHTS AT 50
50Hz
Hz, 2 POLES
PUMP TYPE DIMENSIONS (mm) WEIGHT
85
ESHS SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES
86
ESHS SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHS 4 poli
WEIGHTS AT 50
50Hz
Hz, 4 POLES
PUMP TYPE DIMENSIONS (mm) WEIGHT
87
ESH SERIES
DIMENSIONS AND WEIGHTS (BARE SHAFT)
88
ESH SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESH (bare(BARE
WEIGHTS shaft) SHAFT)
89
ESHF SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES
90
ESHF SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHF 2 poli
WEIGHTS AT 50
50Hz
Hz, 2 POLES
PUMP TYPE DIMENSIONS (mm) s WEIGHT COUPLING
91
ESHF SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 4 POLES
92
ESHF SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHF 4 poli
WEIGHTS AT 50
50Hz
Hz, 4 POLES
PUMP TYPE DIMENSIONS (mm) s WEIGHT COUPLING
93
ESHC SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz, 2 POLES
94
ESHC SERIES
DIMENSIONI E PESI
DIMENSIONS AND SERIE ESHC 2 poli
WEIGHTS AT 5050 Hz
Hz, 2 POLES
PUMP TYPE DIMENSIONS (mm) s WEIGHT
COUPLING
TYPE
ESHC..2 FOR
95
ESH..H
(ESH WITH HYDROVAR)
96
ESH..H SERIES
(ESH WITH HYDROVAR)
Background and context Special features / benefits
In all areas of application, such as building services, There is no need for additional pressure
industry, agriculture and air-handling, the demand for sensors: ESH..H are fitted with a pressure transmitter
intelligent pumping systems is constantly growing. or differential pressure transmitters, depending on the
There are many advantages: reduced cost for pump life application.
cycle, lower environmental impact, longer lifetime of
pipes and unions. Thats why Xylem has developed the There is no need for special pumps or
ESH..H: an intelligent pumping system which assures high motors.
level performance with energy consumption tailored to
demand. There is no need for bypass or safety
systems: with HYDROVAR the pump immediately
Benefits of NSC with HYDROVAR switches off when demand drops to zero or when it
exceeds maximum pump capacity. This makes it
Saving: ESH..H transforms ESH pumps into variable unnecessary to install additional safety devices.
speed intelligent pumping systems. Thanks to the
HYDROVAR system, the speed of each pump varies so Anti-condensation device: all units are fitted
as to maintain a constant flow or pressure or differential with anti-condensation devices which switch on when
pressure. The pump only receives the energy required, the pump is in standby in order to prevent condensation
thus allowing considerable savings, especially for those forming in the unit.
systems in which demands varies during the day.
NSC_M0004_A_ot
97
ESH..H SERIES Lowara
(ESH WITH HYDROVAR)
OPERATING PRINCIPLE
The basic function of the HYDROVAR device is to control the
pump to meet the system demands.
The basic function of the HYDROVAR device is to
control the pump to meet the system demands.
HYDROVAR performs these functions by:
1) Measuring
HYDROVAR the system pressure or flow via a
performs these functions by:
transmitter
1) Measuring the mounted
system on the pumps
pressure or flow delivery
via a side.
2)transmitter
Calculatingmounted
the motoronspeed to maintain
the pumps delivery theside.
correct
flow or pressure.
2) Calculating the motor speed to maintain the correct
3)flow
Sending out a signal to the pump to start the motor,
or pressure.
increase out
3) Sending speed, decrease
a signal to the speed
pump ortostop.
start the motor, Control for constant pressure
4)increase
In the case of multiple pump
speed, decrease speed or stop. installations,
4) In the case ofwill
HYDROVAR multiple pump installations,
automatically provide for the cyclic
HYDROVAR
changeover of willtheautomatically
pumps starting provide for the cyclic
sequence.
changeover of the pumps starting sequence
In addition to these basic functions, HYDROVAR can do
In addition
things onlytobythese
the mostbasicadvanced
functions,computerised
HYDROVAR control can do
things only by
systems, such as: the most advanced computerised control
systems,
Stop the such as:
pump(s) at zero demand.
Stop
Stop the pump(s)at
the pump(s) in zero
case demand.
of water failure on the suction
Stop the pump(s) in casedry
side (protection against running).
of water failure on the
suction
Stop the pump
side if the required
(protection againstdelivery exceeds the pumps
dry running).
Stop the pump if the required delivery exceeds by
capacity (protection against cavitation caused theexcessive Control to match a system curve
pumps capacity (protection against cavitation causedin a
demand), or automatically switch on the next pump
multiple
by series.
excessive demand), or automatically switch on the
next
Protect
pumptheinpump and motor
a multiple series.from overvoltage,
Protect the pump and motorearth
undervoltage, overload and from fault.
overvoltage,
undervoltage,
Vary the pumpoverload
speed acceleration
and earth fault. and deceleration time.
Compensate for increased flow resistance at high flow
Vary the pump speed acceleration and deceleration
rates.
time.
Conduct automatic test starts at set intervals.
Compensate
Monitor the for increased
converter andflowmotor resistance
operating at high
hours.flow
rates.
Display all functions on an LCD in different languages
Conduct automatic
(Italian, English, test starts
French, German, at set intervals.
Spanish, Portuguese,
Control for constant flow
Monitor
Dutch). the converter and motor operating hours.
Display
Send a all
signal to a remote
functions on an control system which
LCD in different is
languages
proportional
(Italian, English,to the
French,pressure
German,and Spanish,
frequency. Portuguese,
Dutch).
Communicate with another HYDROVAR or control
system via anto
Send a signal RSa485 remoteinterface.
control system which is
proportional to the pressure and frequency.
Communicate with another HYDROVAR or control
system via an RS 485 interface.
98
ACCESSORIES
99
FLEXIBLE COUPLING DIMENSIONS
100
SPACER COUPLING DIMENSIONS
101
DIMENSIONS OF ROUND THREADED
COUNTERFLANGES ACCORDING TO EN 1092-1
102
ESH SERIES
SHIM FOR MOTOR FEET
103
REPORTS AND
DECLARATIONS
104
REPORTS AND DECLARATIONS
i) Test reports
f) Declaration of product conformity with the technical requirements indicated in the order
N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number (date
+ progressive number).
105
106
TECHNICAL
APPENDIX
107
ESH SERIES
TYPICAL APPLICATIONS
Water Purification: Waste Management:
De-ionized water Waste treatment
Water Treatment Pollution control
Filtration
Commercial Pools
Graphics: Laundry:
Film washing Commercial washing
Cooling of presses
TECHNICAL APPENDIX
108
NPSH
The minimum operating values that can be reached at the The maximum possible suction head for installation
pump suction end are limited by the onset of cavitation. depends on the value of the atmospheric pressure
(i.e. the elevation above sea level at which the pump
Cavitation is the formation of vapour-filled cavities within is installed) and the temperature of the liquid.
liquids where the pressure is locally reduced to a critical value,
or where the local pressure is equal to, or just below the To help the user, with reference to water temperature
vapour pressure of the liquid. (4 C) and to the elevation above sea level, the
following tables show the drop in hydraulic pressure
The vapour-filled cavities flow with the current and head in relation to the elevation above sea level, and
when they reach a higher pressure area the vapour the suction loss in relation to temperature.
contained in the cavities condenses. The cavities collide,
generating pressure waves that are transmitted to the Water
walls. These, being subjected to stress cycles, gradually temperature (C) 20 40 60 80 90 110 120
become deformed and yield due to fatigue. This Suction
phenomenon, characterized by a metallic noise loss (m) 0,2 0,7 2,0 5,0 7,4 15,4 21,5
produced by the hammering on the pipe walls, is called
incipient cavitation.
Elevation above
sea level (m) 500 1000 1500 2000 2500 3000
The damage caused by cavitation may be magnified by
electrochemical corrosion and a local rise in Suction
temperature due to the plastic deformation of the loss (m) 0,55 1,1 1,65 2,2 2,75 3,3
walls. The materials that offer the highest resistance to
heat and corrosion are alloy steels, especially austenitic Friction loss is shown in the tables at pages 111-112 of
steel. The conditions that trigger cavitation may be this catalogue. To reduce it to a minimum, especially
assessed by calculating the total net suction head, in cases of high suction head (over 4-5 m.) or within
referred to in technical literature with the acronym the operating limits with high flow rates, we
NPSH (Net Positive Suction Head). recommend using a suction line having a larger
diameter than that of the pumps suction port.
The NPSH represents the total energy (expressed in m.) It is always a good idea to position the pump as close
of the liquid measured at suction under conditions of as possible to the liquid to be pumped.
incipient cavitation, excluding the vapour pressure
(expressed in m.) that the liquid has at the pump inlet. Make the following calculation:
To find the static height hz at which to install the Liquid: water at ~15C = 1 kg/dm3
machine under safe conditions, the following formula Flow rate required: 25 m3/h
must be verified: Head for required delivery: 70 m.
Suction lift: 3,5 m.
hp + hz (NPSHr + 0.5) + hf + hpv 1
The selection is an 33SV3G075T pump whose NPSH
required value is, at 25 m3/h, of 2 m.
where:
hp is the absolute pressure applied to the free liquid For water at 15 C
surface in the suction tank, expressed in m. of
liquid; hp is the quotient between the barometric hp = Pa / = 10,33m, hpv = Pv / = 0,174m (0,01701 bar)
pressure and the specific weight of the liquid.
hz is the suction lift between the pump axis and the The Hf flow resistance in the suction line with foot
free liquid surface in the suction tank, expressed valves is ~ 1,2 m.
in m.; hz is negative when the liquid level is By substituting the parameters in formula 1 with the
lower than the pump axis. numeric values above, we have:
hf is the flow resistance in the suction line and its
accessories, such as: fittings, foot valve, gate 10,33 + (-3,5) (2 + 0,5) + 1,2 + 0,17
valve, elbows, etc.
hpv is the vapour pressure of the liquid at the from which we have: 6,8 > 3,9
operating temperature, expressed in m. of
liquid. hpv is the quotient between the Pv vapour The relation is therefore verified.
pressure and the liquids specific weight.
0,5 is the safety factor.
TECHNICAL APPENDIX
109
TENSIONE PRESSURE
VAPOUR DI VAPORE
TABELLA TENSIONE
VAPOUR PRESSUREDI VAPORE
ps ANDps DENSITY OF
E DENSITA' DELL'ACQUA
WATER TABLE
t T ps t T ps t T ps
C K bar kg/dm3 C K bar kg/dm3 C K bar kg/dm3
0 273,15 0,00611 0,9998 55 328,15 0,15741 0,9857 120 393,15 1,9854 0,9429
1 274,15 0,00657 0,9999 56 329,15 0,16511 0,9852 122 395,15 2,1145 0,9412
2 275,15 0,00706 0,9999 57 330,15 0,17313 0,9846 124 397,15 2,2504 0,9396
3 276,15 0,00758 0,9999 58 331,15 0,18147 0,9842 126 399,15 2,3933 0,9379
4 277,15 0,00813 1,0000 59 332,15 0,19016 0,9837 128 401,15 2,5435 0,9362
5 278,15 0,00872 1,0000 60 333,15 0,1992 0,9832 130 403,15 2,7013 0,9346
6 279,15 0,00935 1,0000 61 334,15 0,2086 0,9826 132 405,15 2,867 0,9328
7 280,15 0,01001 0,9999 62 335,15 0,2184 0,9821 134 407,15 3,041 0,9311
8 281,15 0,01072 0,9999 63 336,15 0,2286 0,9816 136 409,15 3,223 0,9294
9 282,15 0,01147 0,9998 64 337,15 0,2391 0,9811 138 411,15 3,414 0,9276
10 283,15 0,01227 0,9997 65 338,15 0,2501 0,9805 140 413,15 3,614 0,9258
11 284,15 0,01312 0,9997 66 339,15 0,2615 0,9799 145 418,15 4,155 0,9214
12 285,15 0,01401 0,9996 67 340,15 0,2733 0,9793 155 428,15 5,433 0,9121
13 286,15 0,01497 0,9994 68 341,15 0,2856 0,9788 160 433,15 6,181 0,9073
14 287,15 0,01597 0,9993 69 342,15 0,2984 0,9782 165 438,15 7,008 0,9024
15 288,15 0,01704 0,9992 70 343,15 0,3116 0,9777 170 433,15 7,920 0,8973
16 289,15 0,01817 0,9990 71 344,15 0,3253 0,9770 175 448,15 8,924 0,8921
17 290,15 0,01936 0,9988 72 345,15 0,3396 0,9765 180 453,15 10,027 0,8869
18 291,15 0,02062 0,9987 73 346,15 0,3543 0,9760 185 458,15 11,233 0,8815
19 292,15 0,02196 0,9985 74 347,15 0,3696 0,9753 190 463,15 12,551 0,8760
20 293,15 0,02337 0,9983 75 348,15 0,3855 0,9748 195 468,15 13,987 0,8704
21 294,15 0,24850 0,9981 76 349,15 0,4019 0,9741 200 473,15 15,550 0,8647
22 295,15 0,02642 0,9978 77 350,15 0,4189 0,9735 205 478,15 17,243 0,8588
23 296,15 0,02808 0,9976 78 351,15 0,4365 0,9729 210 483,15 19,077 0,8528
24 297,15 0,02982 0,9974 79 352,15 0,4547 0,9723 215 488,15 21,060 0,8467
25 298,15 0,03166 0,9971 80 353,15 0,4736 0,9716 220 493,15 23,198 0,8403
26 299,15 0,03360 0,9968 81 354,15 0,4931 0,9710 225 498,15 25,501 0,8339
27 300,15 0,03564 0,9966 82 355,15 0,5133 0,9704 230 503,15 27,976 0,8273
28 301,15 0,03778 0,9963 83 356,15 0,5342 0,9697 235 508,15 30,632 0,8205
29 302,15 0,04004 0,9960 84 357,15 0,5557 0,9691 240 513,15 33,478 0,8136
30 303,15 0,04241 0,9957 85 358,15 0,5780 0,9684 245 518,15 36,523 0,8065
31 304,15 0,04491 0,9954 86 359,15 0,6011 0,9678 250 523,15 39,776 0,7992
32 305,15 0,04753 0,9951 87 360,15 0,6249 0,9671 255 528,15 43,246 0,7916
33 306,15 0,05029 0,9947 88 361,15 0,6495 0,9665 260 533,15 46,943 0,7839
34 307,15 0,05318 0,9944 89 362,15 0,6749 0,9658 265 538,15 50,877 0,7759
35 308,15 0,05622 0,9940 90 363,15 0,7011 0,9652 270 543,15 55,058 0,7678
36 309,15 0,05940 0,9937 91 364,15 0,7281 0,9644 275 548,15 59,496 0,7593
37 310,15 0,06274 0,9933 92 365,15 0,7561 0,9638 280 553,15 64,202 0,7505
38 311,15 0,06624 0,9930 93 366,15 0,7849 0,9630 285 558,15 69,186 0,7415
39 312,15 0,06991 0,9927 94 367,15 0,8146 0,9624 290 563,15 74,461 0,7321
40 313,15 0,07375 0,9923 95 368,15 0,8453 0,9616 295 568,15 80,037 0,7223
41 314,15 0,07777 0,9919 96 369,15 0,8769 0,9610 300 573,15 85,927 0,7122
42 315,15 0,08198 0,9915 97 370,15 0,9094 0,9602 305 578,15 92,144 0,7017
43 316,15 0,09639 0,9911 98 371,15 0,9430 0,9596 310 583,15 98,70 0,6906
44 317,15 0,09100 0,9907 99 372,15 0,9776 0,9586 315 588,15 105,61 0,6791
45 318,15 0,09582 0,9902 100 373,15 1,0133 0,9581 320 593,15 112,89 0,6669
46 319,15 0,10086 0,9898 102 375,15 1,0878 0,9567 325 598,15 120,56 0,6541
47 320,15 0,10612 0,9894 104 377,15 1,1668 0,9552 330 603,15 128,63 0,6404
48 321,15 0,11162 0,9889 106 379,15 1,2504 0,9537 340 613,15 146,05 0,6102
49 322,15 0,11736 0,9884 108 381,15 1,3390 0,9522 350 623,15 165,35 0,5743
50 323,15 0,12335 0,9880 110 383,15 1,4327 0,9507 360 633,15 186,75 0,5275
51 324,15 0,12961 0,9876 112 385,15 1,5316 0,9491 370 643,15 210,54 0,4518
52 325,15 0,13613 0,9871 114 387,15 1,6362 0,9476 374,15 647,30 221,20 0,3154
53 326,15 0,14293 0,9862 116 389,15 1,7465 0,9460
54 327,15 0,15002 0,9862 118 391,15 1,8628 0,9445
G-at_npsh_b_sc
TECHNICAL APPENDIX
110
TABLE OF FLOW RESISTANCE IN 100 m OF STRAIGHT
CAST
TABELLAIRON
PERDITEPIPELINE
DI CARICO PER (HAZEN-WILLIAMS FORMULA
100 m TUBAZIONE DIRITTA IN GHISA C=100) C=100)
(FORMULA HAZEN-WILLIAMS
TECHNICAL APPENDIX
111
FLOW RESISTANCE
TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND
GATES
The flow resistance is calculated using the equivalent pipeline length method according to the table below:
ACCESSORY DN
TYPE 25 32 40 50 65 80 100 125 150 200 250 300
Equivalent pipeline length (m)
45 bend 0,2 0,2 0,4 0,4 0,6 0,6 0,9 1,1 1,5 1,9 2,4 2,8
90 bend 0,4 0,6 0,9 1,1 1,3 1,5 2,1 2,6 3,0 3,9 4,7 5,8
90 smooth bend 0,4 0,4 0,4 0,6 0,9 1,1 1,3 1,7 1,9 2,8 3,4 3,9
Union tee or cross 1,1 1,3 1,7 2,1 2,6 3,2 4,3 5,3 6,4 7,5 10,7 12,8
Gate - - - 0,2 0,2 0,2 0,4 0,4 0,6 0,9 1,1 1,3
Non return valve 1,1 1,5 1,9 2,4 3,0 3,4 4,7 5,9 7,4 9,6 11,8 13,9
G-a-pcv-en_a_th
The table is valid for the Hazen Williams coefficient C=100 (cast iron pipework);
for steel pipework, multiply the values by 1,41;
for stainless steel, copper and coated cast iron pipework, multiply the values by 1,85;
When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of
flow resistance.
The values given are guideline values which are bound to vary slightly according to the model, especially for gate
valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers.
TECHNICAL APPENDIX
112
VOLUMETRIC CAPACITY
Litres Cubic metres Cubic feet Cubic feet Imperial gallon U.S. gallon
per minute per hour per hour per minute per minute per minute
l/min m3/h ft3/h ft3/min Imp. gal/min US gal/min
1,0000 0,0600 2,1189 0,0353 0,2200 0,2642
16,6667 1,0000 35,3147 0,5886 3,6662 4,4029
0,4719 0,0283 1,0000 0,0167 0,1038 0,1247
28,3168 1,6990 60,0000 1,0000 6,2288 7,4805
4,5461 0,2728 9,6326 0,1605 1,0000 1,2009
3,7854 0,2271 8,0208 0,1337 0,8327 1,0000
LENGTH
Millimetre Centimetre Metre Inch Foot Yard
mm cm m in ft yd
VOLUME
Cubic metre Litre Millilitre Imperial gallon U.S. gallon Cubic foot
TEMPERATURE
Water Kelvin Celsius Fahrenheit
K C F F = C 95 + 32
icing 273,1500 0,0000 32,0000 C = (F 32) 59
boiling 373,1500 100,0000 212,0000
G-at_pp-en_b_sc
TECHNICAL APPENDIX
113
FURTHER PRODUCT SELECTION
AND DOCUMENTATION
XylectTM
XylectTM is pump solution selection software with an extensive online database of product information across the entire
range of pumps and related products, with multiple search options and helpful project management facilities. The
system holds up-to-date product information on thousands of products and accessories.
The possibility to search by applications and the detailed information output given makes it easy to make the optimal
selection without having detailed knowledge about the products.
TECHNICAL APPENDIX
114
FURTHER PRODUCT SELECTION
AND DOCUMENTATION
XylectTM
The detailed output makes it easy to select the optimal pump from the given alternatives.
TECHNICAL APPENDIX
115
Xylem |zl m| e
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
Were approximately 12,500 people unified in a common purpose: creating innovative solutions to meet our
worlds water needs. Developing new technologies that will improve the way water is used, conserved, and re-
used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we
help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we
have strong, long-standing relationships with customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of innovation.