Valve Sizing and Selection: FREE Resources
Valve Sizing and Selection: FREE Resources
Valve Sizing and Selection: FREE Resources
Sizing flow valves is a science with many rules of thumb that few people agree on. In this
article I'll try to define a more standard procedure for sizing a valve as well as helping to select
the appropriate type of valve. **Please note that the correlation within this article are for
turbulent flow
Ads by Goooooogle Advertise on this site
STEP #1: Define the system All About Valve Monitors
The system is pumping water from one tank Free Download - Learn To Specify The Right Monitor &
Solve Problems
to another through a piping system with a total www.MoniteurDevices.com
pressure drop of 150 psi. The fluid is water at Mass Flow & Pressure
70 0F. Design (maximum) flowrate of 150 meters and controllers for gases and liquids, accurate and
gpm, operating flowrate of 110 gpm, and a fast
www.bronkhorst.com
minimum flowrate of 25 gpm. The pipe
ball valve
diameter is 3 inches. At 70 0F, water has a Specialized in manufacturing all kinds of Stainless Steel
specific gravity of 1.0. Ball Valve
weidouli.en.alibaba.com
Key Variables: Total pressure drop, design
ABZ Butterfly Valves
flow, operating flow, minimum flow, pipe Industrial Butterfly Valves for any industry. 2"-80" size
diameter, specific gravity range
www.abzvalve.com
http://www.cheresources.com/valvezz.shtml 03/03/2007
Valve Sizing and Selection Page 2 of 6
At this point, some people would be tempted to go to the valve charts or characteristic curves and
select a valve. Don't make this mistake, instead, proceed to Step #4!
Before a valve can be selected, you have to decide what type of valve will be used (See the list
of valve types later in this article). For our case, we'll assume we're using an equal percentage,
globe valve (equal percentage will be explained later). The valve chart for this type of valve is
shown below. This is a typical chart that will be supplied by the manufacturer (as a matter of
fact, it was!)
For our case, it appears the 2 inch valve will work well for our Cv value at about 80-85% of the
stroke range. Notice that we're not trying to squeeze our Cv into the 1 1/2 valve which would
need to be at 100% stroke to handle our maximum flow. If this valve were used, two
consequences would be experienced: the pressure drop would be a little higher than 15 psi at our
design (max) flow and the valve would be difficult to control at maximum flow. Also, there
would be no room for error with this valve, but the valve we've chosen will allow for flow surges
http://www.cheresources.com/valvezz.shtml 03/03/2007
Valve Sizing and Selection Page 3 of 6
STEP #5: Check the Cv and stroke percentage at the minimum flow
If the stroke percentage falls below 10% at our minimum flow, a smaller valve may have to be
used in some cases. Judgements plays role in many cases. For example, is your system more
likely to operate closer to the maximum flowrates more often than the minimum flowrates? Or is
it more likely to operate near the minimum flowrate for extended periods of time. It's difficult to
find the perfect valve, but you should find one that operates well most of the time. Let's check
the valve we've selected for our system:
Referring back to our valve chart, we see that a Cv of 6.5 would correspond to a stroke
percentage of around 35-40% which is certainly acceptable. Notice that we used the maximum
pressure drop of 15 psi once again in our calculation. Although the pressure drop across the
valve will be lower at smaller flowrates, using the maximum value gives us a "worst case"
scenario. If our Cv at the minimum flow would have been around 1.5, there would not really be
a problem because the valve has a Cv of 1.66 at 10% stroke and since we use the maximum
pressure drop, our estimate is conservative. Essentially, at lower pressure drops, Cv would only
increase which in this case would be advantageous.
The difference between these values should be less than 50% of the higher value.
0.5 (3.3) = 1.65
and 3.3 - 2.2 = 1.10. Since 1.10 is less than 1.65, there should be no problem in controlling the
valve. Also note that the gain should never be less than 0.50. So for our case, I believe our
selected valve will do nicely!
http://www.cheresources.com/valvezz.shtml 03/03/2007
Valve Sizing and Selection Page 4 of 6
OTHER NOTES:
Another valve characteristic that can be examined is called the choked flow. The relation uses
the FL value found on the valve chart. I recommend checking the choked flow for vastly
different maximum and minimum flowrates. For example if the difference between the
maximum and minimum flows is above 90% of the maximum flow, you may want to check the
choked flow. Usually, the rule of thumb for determining the maximum pressure drop across the
valve also helps to avoid choking flow.
When speaking of valves, it's easy to get lost in the terminology. Valve types are used to
describe the mechanical characteristics and geometry (Ex/ gate, ball, globe valves). We'll use
valve control to refer to how the valve travel or stroke (openness) relates to the flow:
1. Equal Percentage: equal increments of valve travel produce an equal percentage in flow
change
2. Linear: valve travel is directly proportional to the valve stoke
3. Quick opening: large increase in flow with a small change in valve stroke
So how do you decide which valve control to use? Here are some rules of thumb for each one:
1. Equal Percentage (most commonly used valve control)
a. Used in processes where large changes in pressure drop are expected
b. Used in processes where a small percentage of the total pressure drop is permitted by the
valve
c. Used in temperature and pressure control loops
2. Linear
a. Used in liquid level or flow loops
b. Used in systems where the pressure drop across the valve is expected to remain fairly constant
(ie. steady state systems)
3. Quick Opening
a. Used for frequent on-off service
b. Used for processes where "instantly" large flow is needed (ie. safety systems or cooling water
systems)
Now that we've covered the various types of valve control, we'll take a look at the most common
valve types.
Gate Valves
Best Suited Control: Quick Opening
Recommended Uses:
1. Fully open/closed, non-throttling
2. Infrequent operation
3. Minimal fluid trapping in line
Advantages: Disadvantages:
http://www.cheresources.com/valvezz.shtml 03/03/2007
Valve Sizing and Selection Page 5 of 6
Globe Valves
Best Suited Control: Linear and Equal percentage
Recommended Uses:
1. Throttling service/flow regulation
2. Frequent operation
Advantages: Disadvantages:
1. Efficient throttling 1. High pressure drop
2. Accurate flow control 2. More expensive than other valves
3. Available in multiple ports
Ball Valves
Best Suited Control: Quick opening, linear
Recommended Uses:
1. Fully open/closed, limited-throttling
2. Higher temperature fluids
Advantages: Disadvantages:
1. Low cost 1. Poor throttling characteristics
2. High capacity 2. Prone to cavitation
3. Low leakage and maint.
4. Tight sealing with low torque
Butterfly Valves
Best Suited Control: Linear, Equal percentage
http://www.cheresources.com/valvezz.shtml 03/03/2007
Valve Sizing and Selection Page 6 of 6
Recommended Uses:
1. Fully open/closed or throttling services
2. Frequent operation
3. Minimal fluid trapping in line
Advantages: Disadvantages:
1. Low cost and maint. 1. High torque required for control
2. High capacity 2. Prone to cavitation at lower flows
3. Good flow control
4. Low pressure drop
Other Valves
Another type of valve commonly used in conjunction with other valves is called a check
valve. Check valves are designed to restrict the flow to one direction. If the flow reverses
direction, the check valve closes. Relief valves are used to regulate the operating pressure of
incompressible flow. Safety valves are used to release excess pressure in gases or compressible
fluids.
References:
Rosaler, Robert C., Standard Handbook of Plant Engineering, McGraw-Hill, New York, 1995,
pages 10-110 through 10-122
Purcell, Michael K., "Easily Select and Size Control Valves", Chemical Engineering Progress,
March 1999, pages 45-50
http://www.cheresources.com/valvezz.shtml 03/03/2007