A11v0 e
A11v0 e
97
Operating Fluid
Mineral oil (no code)
Mode of operation
Pump in open circuit O
Size
Displacement Vg max (cm3) 40 60 75 95 130 190 260
In case of controls with various additional functions take care of the sequence of the columns. For each column only 1 option is possible!
= available
= in preparation, available on enquiry = preferred program (preferred types see page 32)
= not available
A11V O / 1 12
Axial piston unit
Charge pump
Mode of operation
Size
Control device
Series
1
Index
sizes 40...130 0
sizes 190...260 1
Direction of rotation
viewed on shaft end clockwise R
anti-clockwise L
Seals
NBR (nitril-caoutchouc), shaft seal in FPM (fluor-caoutchouc) N
FPM (fluor-caoutchouc) V
Shaft end 40 60 75 95 130 190 260
Splined shaft DIN 5480 Z
Parallel with key DIN 6885 P
Splined shaft SAE standard for single pump S
standard for combination pump 1) 1) T
1) Use shaft end S for combination pump
Mounting flange
SAE 2-hole C
SAE 4-hole D
Service line connections 40 60 75 95 130 190 260
Pressure and suction port SAE on (opposite) side,
12
metric mounting threads
Through drive (assembly possibilities see page 30) 40 60 75 95 130 190 250
hub flange
N00
SAE A (N 5/8"-9T 16/32 DP) SAE A, 2-hole K01
SAE B (N 7/8"-13T 16/32 DP) SAE B, 2-hole K02
SAE B-B (N 1"-15T 16/32 DP) SAE B, 2-hole K04
SAE C (N 1 1/4"-14T 12/24 DP) SAE C, 2-hole K07
SAE C (N 1 1/4"-14T 12/24 DP) SAE D, 4-hole K86
SAE C-C (N 1 1/2"-17T 12/24 DP) SAE C, 2-hole K24
SAE D (N 1 3/4"-13T 8/16 DP) SAE D, 4-hole K17
SAE D (N 1 3/4"-13T 8/16 DP) SAE E, 4-hole K72
N 30 (DIN 5480) SAE C, 2-hole K80
N 35 (DIN 5480) SAE B, 2-hole K79
N 35 (DIN 5480) SAE C, 2-hole K61
N 40 (DIN 5480) SAE D, 4-hole K81
N 45 (DIN 5480) SAE D, 4-hole K82
N 50 (DIN 5480) SAE D, 4-hole K83
N 50 (DIN 5480) SAE E, 4-hole K84
N 60 (DIN 5480) SAE E, 4-hole K67
Technical Data
Fluid
We request that before starting a project detailed information Important: The leakage oil (case drain oil) temperature is
about the choice of pressure fluids and application conditions influenced by pressure and pump speed and is always higher
are taken from our catalogue sheets RE 90220 (mineral oil), than the tank temperature. However, at no point in the circuit
RE 90221 (environmentally acceptable hydraulic fluids) and may the temperature exceed 115C.
RE 90223 (fire resistant hydraulic fluids, HF). If it is not possible to comply with the above conditions because
When using HF- or environmentally acceptable hydraulic fluids of extreme operating parameters or high ambient temperatures
possible limitations for the technical data have to be taken into please consult us.
consideration. If necessary please consult our technical depart-
ment (please indicate type of the hydraulic fluid used for your Filtration
application on the order sheet). The operation with HFA-, HFB- and The finer the filtration the better the achieved purity grade of the
HFC- hydraulic fluids requires additional special measures. pressure fluid and the longer the life of the axial piston unit. To
ensure the functioning of the axial piston unit a minimum purity
Operating viscosity range grade of:
In order to obtain optimum efficiency and service life, we 9 to NAS 15, 38
recommend that the operating viscosity (at operating tem- 6 to SAE
perature) be selected from within the range: 18/15 to ISO/DIS 4406 is necessary.
In this case we recommend, depending on system and
opt = operating viscosity 16...36 mm2/s
application filter element 20 100 for the A11VO.
referred to tank temperature (open circuit). With the rising differential pressure at the filter element the
-value must not decrease.
Viscosity limits At very high temperatures of the hydraulic fluid (90C to max.
The limiting values for viscosity are as follows: 115C) at least cleanless class
min = 5 mm2/s, 8 to NAS 1638
short term at a max. permissible temp. of tmax = 115C 5 to SAE
17/14 to ISO/DIS 4406 is necessary.
max = 1600 mm2/s, short term on cold start (tmin = -40C)
If above mentioned grades cannot be maintained please consult
Please note that the max. fluid temperature is also not exceeded us.
in certain areas (for instance bearing area).
At temperatures of -25C up to -40C special measures may be Operating pressure range inlet
required for certain installation positions. Please contact us for Absolute pressure at port S (suction port)
further information. Design without charge pump (impeller)
pabs min _______________________________________________________________ 0,8 bar
Selection diagram pabs max _________________________________________________________________ 30 bar
2500-40 -20 0 20 40 60 80 100
1600 1600 Design with charge pump (impeller)
1000 pabs min _______________________________________________________________ 0,6 bar
600 pabs max __________________________________________________________________ 2 bar
400
V 68
VG
V 32
V 46
VG 2
200
G
G
G
10
2
60 Pressure at port A or B
40 36 Nominal pressure _________________________________________ pN = 350 bar
Peak pressure __________________________________________ pmax = 400 bar
opt.
Viskositt
20
16
Case drain pressure
viscosity
Technical Data
Table of values (theoretical values, without considering mh and v; values rounded)
Size 40 60 75 95 130 190 260
3
Displacement Vg max cm 42 58,3 74 93,8 130 192,7 260
Vg min cm3 0 0 0 0 0 0 0
1
Max. speed ) at Vg max nmax 1 rpm 3000 2700 2550 2350 2100 2100 1800
Max. perm. speed (speed limit)
with increased inlet pressure pabs at suction port S nmax perm. rpm 3500 3250 3000 2780 2500 2500 2300
or at Vg V g max (qv qv max 1) (see diagram below)
Max. flow2) at nmax 1 (Vg max) qV max 1 L/min 122 153 183 214 265 393 454
Max. power at qV max 1 (p = 350 bar) Pmax 1 kW 71 92 110 129 159 236 273
Permissible continuous duty (p = 350 bar) TN Nm 234 324 412 522 723 1073 1447
torque at Vg max max. perm. intermittant (p = 400 bar) Tmax Nm 267 370 471 597 826 1225 1654
2
Moment of inertia about drive axis J kgm 0,0048 0,0082 0,0115 0,0173 0,0318 0,0878
Weight (approx.) m kg 28 36 45 53 66 125
Table of values A11VLO with charge pump (impeller) (theoretical values, without considering mh and v; values rounded)
Size 130 200 260
Displacement Vg max cm3 130 192,7 260
Vg min cm3 0 0 0
3
Max. speed ) at Vg max nmax 1 rpm 2500 2500 2300
Max. flow 2) at nmax 1 (Vg max) qV max 1 L/min 315 467 580
Max. power at qV max 1 (p = 350 bar) Pmax 1 kW 190 281 349
Moment of inertia about drive axis J kgm2 0,0337
Weight (approx.) m kg 69 130
1
) The values shown are valid for an absolute pressure (pabs) of 1 bar at the suction inlet S and when operated on mineral oil.
2
) 3 % volumetric loss included
3
) The values shown are valid for an absolute pressure (pabs) of at least 0,8 bar and when operated on mineral oil.
1,1 2 T n Tn
Drive power P= = = in kW
60000 9549 600 t
pabs = 1 bar
1,0
Vg = geom. displacement per rev. in cm3
p = differential pressure in bar
0,9 n = speed in rpm
0,8 1,0
0,9 v = volumetric efficiency
displacement Vg/Vg max mh = mech-hyd. efficiency
Mounting position t = overall efficiency (t = v mh )
With the drive shaft to horizontal position; alternative
mounting positions are possible, please consult us.
The pump housing must be filled with fluid during
commissioning and during normal operation.
For extensive information on the installation position,
please read our data sheet RE 90270.
The constant pressure control maintains the pressure in a Variation: Load sensing control (DRS)
hydraulic system constant whithin its control range in spite of The load sensing valve is a flow control valve which operates as a
changing pump flow requirements. The variable pump supplies function of the load pressure to regulate the pump displacement in
only the volume of fluid required by the consumer. Should order to match the requirement of the consumer unit.
operating pressure exceed the set pressure, the pump is auto- The pump flow is influenced by the external orifice (control block,
matically swivelled back to a smaller angle and the deviation in throttle) fitted between pump and serviced unit, but is not affected
control corrected. by load pressure throughout the range below the set pressure.
In unoperated (zero pressure) condition, the pump is swivelled The valve compares pressure before and after the orifice and
to its starting position (Vg max) by means of a control spring. maintains the pressure drop (differential pressure p) across
the orifice and therefore the pump flow constant.
Setting range from 50 to 350 bar If differential pressure p increases, the pump is swivelled back
towards Vg min, and if p decreases the pump is swivelled out
max. 10 bar
p max towards Vg max until a balance is restored within the valve.
350
porifice = ppump pserviced unit
300
p may be set within the range 14 bar to 25 bar.
operating press. pB in bar
setting range
M A G T1 R T2
operating press. pB in bar
Vg max Vg min
flow qV in L/min
orifice
M A G X T1 R T2
S M1
Constant pressure control DR
(integral valve) fixed setting;
with charge pump (impeller)
S M1
Constant pressure control
with load sensing valve, DRS
Variation: Remote constant pressure control (DRG) Variation: Pressure control for parallel operation (DRL)
The remote control pressure control can be set by means of a The DRL pressure control is suitable for pressure control of
separately mounted pressure relief valve (1) and a lower pressure several A11VO axial piston pumps working in parallel.
command value. With an external pressure relief valve (1) the pressure command
Adjustment range from 50 to 350 bar. value for all pumps mounted onto the system can be preset.
Alternatively the system can be started at low operating pressures Adjustment range from 50 to 350 bar.
(stand-by pressure) by actuating a 2/2 control valve (2), also
Each pump can be disconnected from the system by means of
separately mounted.
a separately mounted 3/2 control valve (2).
Both functions can be carried out either singly or in combination
Provision should be made for the check valves (3) in either the
(see circuit diagram).
delivery line (port A) or the pilot line (port X).
The external valves are not included in delivery volume.
The external valves are not included in delivery volume.
For a separate pressure relief valve (1) we recommend:
For a separate pressure relief valve (1) we recommend:
DBDH 6 (manual actuation) see RE 25402
DBDH 6 (manual actuation) see RE 25402
max. 10 bar
p max
350
1
300 3
operating press. pB in bar
2
250
setting range
M A G MA2 X 3 T1 R T2
200
150 MD
100
50
0
flow qV in L/min Vg max Vg min
Ms
2 1
S M1
max. 5 m
M A G X T1 R T2
Vg max Vg min
S M1
Remote constant pressure control, DRG
The constant power control controls the output volume of the Variation: Integral pressure cut-off (LRD)
pump in relation to the operating pressure so that, at a constant The pressure cut-off is in effect a constant pressure control
drive speed, the preset drive power is not exceeded. which swivels the pump back to Vg min when the preset operating
pB = operating pressure pressure is reached.
pB Vg = constant This function overrides the constant power control, i.e. the constant
Vg = displacement
power control is effective below the preset operating pressure.
Optimum power usage is obtained by accurately following the The valve is integrated into the control housing and is set in the
power hyberbola. factory to a fixed pressure.
M A G T1 R T2
S M1 S M1
Constant power control LR Constant power control with integral
pressure cut-off (fixed setting), LRD
The output power curve is influenced by the efficiency of the pump.
When ordering, state in clear text:
input power P (kW)
input speed n (rpm)
max. output flow qV max (L/min)
After all technical details have been clarified, a power diagram
can be produced by computer.
Variation: Load sensing valve (LRS) Variation: Electrical stroke limiter (LRU1, LRU2)
The load sensing valve is a flow control valve which operates as a The electrical stroke limiter allows the displacement to be
function of the load pressure to regulate the pump displacement in infinitely varied or limited as required.
order to match the requirement of the consumer unit. The displacement is set by means of the control current gener-
The pump flow is influenced by the external orifice (control block, ated by the proportional solenoid.
throttle) fitted between pump and serviced unit, but is not affected A 12V DC (U1) or a 24V DC (U2) supply is required for the control
by load pressure throughout the range below the power curve. of the proportional solenoid.
The valve compares pressure before and after the orifice and The electrical stroke limiter is overriden by the constant power
maintains the pressure drop (differential pressure p) across control, i.e. below the power curve (power hyperbola), displacement
the orifice and therefore the pump flow constant. is adjusted in relation to the control current. If the set flow or the
If differential pressure p increases, the pump is swivelled back operating pressure is such that the power curve is exceeded, the
towards Vg min, and if p decreases the pump is swivelled out constant power control overrides the stroke limiter and reduces
towards Vg max, until a balance is restored within the valve. displacement until the power hyperbola is restored.
porifice = ppump pserviced unit LRU1, LRU2 Function: V g min to V g max (positive control)
p may be set within the range 14 bar to 25 bar. As the control current increases, the pump swivels to a larger
The standard setting is 18 bar. (Please state required setting in displacement. (Starting position at zero pressure: Vg max)
clear text). At operating pressure > 30 bar the pump swivels from Vg max to Vg min
The standby pressure for zero stroke operation (orifice closed) (pilot current < start of control).
is insignificant above the p setting. Start of control at approx.: 400 mA (U1) 200 mA (U2)
The constant power control and the pressure cut-off are super- End of control at approx.: 1200 mA (U1) 600 mA (U2)
imposed on the load sensing valve, i.e. the load sensing function
Insulation class IP 54, control from Vg min to Vg max
operates below the set power hyperbola and set pressure.
A pressure of 30 bar is needed for the control. The oil required
The orifice is not included in the standard supply. for this is taken either from the high pressure or from the external
adjustment pressure at port G ( 30 bar).
If the operating pressure is 30 bar and Vg min > 0 no external
control pressure is required and port G should be plugged before
commissioning. If port G is not to be used then the parts of the
shuttle valve are to be removed from the pump (see note on
repair instructions RDE 92500-R).
operating press. pB in bar
800
operating curve LRU2
pilot current I in mA
600
400
200
V g min displacement V g max
0 0,5 1,0 displacement
Vg min Vg V g max
Vg max
orifice M A G T 1 R T2
M A G X T1 R T2
S M1
The following are used for control of the proportional solenoid:
M1 Proportional amplifier PV _______ (see RE 95023)
S
Proportional amplifier VT 2000 ___ (see RE 29908)
Constant power control with pressure cut-off and
Chopper amplifier CV __________ (see RE 95029)
load sensing valve, LRDS
setting range
10
Start of control, (at Vg max ), settable ________ 4 10 bar 4
When ordering, please state required start of control in clear text. displacement
0 0,5 1,0
H1 pilot pressure increase (Vg max Vg min)____ p = 25 bar Vg min Vg V g max
Vg max
35
30
H6 pilot pressure increase (Vg min Vg max )____ p = 10 bar
25
20
pilot press. p St in bar
20
pilot prss. pSt in bar
15 15
setting range
setting range
10 10
4 4
displacement displacement
0 0,5 1,0 0 0,5 1,0
Vg min Vg V g max Vg min Vg V g max
Vg max Vg max
M A G T1 R T2 Y
20
15
setting range
10
4
displacement
0 0,5 1,0
Vg min Vg V g max
Vg max
Vg max Vg min
M A G T1 R T2 Y
S M1
S M1
Constant power control with pressure cut-off
and hydraulic stroke limiter, LRDH1, LRDH5
(Function: Vg max to Vg min)
pHD
M A G T1 R T2
Control of Power Setting Z
S M1
M A G T1 R T2 Z
operating pressure (A11VO)
p St
p HD Power control with
pressure cut-off
and load limiting
control, positive,
Vg max Vg min
LG2D
0 displacement V g max
S M1
HD Hydraulic Control,
Pilot Pressure Related
The pilot pressure related hydraulic control allows stepless setting Variation: Pressure cut-off (HD1D, HD2D)
of the pump displacement in relation to pilot pressure. Control is The pressure cut-off is in effect a constant pressure control
proportional to the pilot pressure applied to port Y (max. 40 bar). which swivels the pump back to Vg min when the preset operating
Control from Vg min to Vg max. pressure is reached.
In unoperated (zero pressure) condition, the pump is swivelled This function overrides the hydraulic control, i.e. the hydraulic
to its starting position (Vg max) by means of a control spring. control is effective below the preset operating pressure.
At operating pressure > 30 bar the pump swivels from Vg max The valve is integrated into the control housing and is set in the
to Vg min (pilot pressure < start of control). factory to a fixed pressure.
A pressure of 30 bar is needed for the control. The oil required
for this is taken either from the high pressure or from the external Setting range from 50 to 350 bar
adjustment pressure at port G ( 30 bar).
If the operating pressure is 30 bar and Vg min > 0 no external integral pressure cut-off
control pressure is required and port G should be plugged before setting range
commissioning. If port G is not to be used then the parts of the
shuttle valve are to be removed from the pump (see note on
repair instructions RDE 92500-R). max
350
HD1
Pilot pressure increase Vg min-Vg max _______________ p = 10 bar
Start of control, settable _____________________ 4 - 10 bar
operating press. pB in bar
15
setting range
10
4
displacement
0 0,5 1,0 50
Vg min Vg V g max min
Vg max
HD2 V g min displacement V g max
Pilot pressure increase Vg min-Vg max _______________ p = 25 bar
Start of control, settable _____________________ 4 - 10 bar
M A G Y T1 R T2
When ordering, please state required start of control in clear text.
35
30
25
pilot press. p St in bar
20
setting range
15
10
4
displacement
0 0,5 1,0
Vg min Vg V g max
Vg max
Vg max Vg min
M A G Y T1 R T2
S M1
Hydraulic control,
Vg max Vg min pilot pressure related,
with integral pressure cut-off (fixed setting),
HD1D, HD2D
S M1
Hydraulic control,
pilot pressure related, HD1, HD2
EP Electrical Control
with Proportional Solenoid
Electrical control allows stepless and programmable setting of Variation: Pressure cut-off (EP.D)
the pump displacement. Control is proportional to solenoid force The pressure cut-off is in effect a constant pressure control
(current strength). The control force at the control piston is which swivels the pump back to Vg min when the preset operating
generated by a proportional solenoid valve. pressure is reached.
A 12V DC (EP1) or a 24V DC (EP2) supply is required for the This function overrides the EP control, i.e. the EP control is
control of the proportional solenoid. effective below the preset operating pressure.
Start of control at approx.: 400 mA (EP1) 200 mA (EP2) The valve is integrated into the control housing and is set in the
End of control at approx.: 1200 mA (EP1) 600 mA (EP2) factory to a fixed pressure.
Insulation class IP 54, control from Vg min to Vg max Setting range from 50 to 350 bar
In unoperated (zero pressure) condition, the pump is swivelled
to its starting position (Vg max) by means of a control spring. integral pressure cut-off
At operating pressure > 30 bar the pump swivels from Vg max setting range
to Vg min (pilot current < start of control).
A pressure of 30 bar is needed for the control. The oil required
for this is taken either from the high pressure or from the external max
350
adjustment pressure at port G ( 30 bar).
If the operating pressure is 30 bar and Vg min > 0 no external
control pressure is required and port G should be plugged before
commissioning. If port G is not to be used then the parts of the
operating press. pB in bar
800
700
current press. I in mA
50
600 min
500
400
V g min displacement V g max
300
M A G T1 R T2
200
100
displacement
0 0,2 0,4 0,6 0,8 1,0
V g min Vg V g max
V g max
M A G T1 R T2
Vg max Vg min
Vg max Vg min S M1
Electrical control with proportional solenoid
and integral pressure cut-off (fixed setting),
EP2D
S M1
Electrical control with proportional solenoid, EP
Note:
The following are used for control of the proportional solenoid: Pumps with EP control may only be mounted within an oil tank
Proportional amplifier PV _______ (see RE 95023) when using mineral hydraulic oils and with oil temperatures in
Proportional amplifier VT 2000 ___ (see RE 29908)
the tank of max. 80 C.
Chopper amplifier CV __________ (see RE 95029)
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
View Y
anti-clockwise rotation
Vg min
M12; 20 deep
V g max
Detail W
clockwise rotation
S
DR/D M10;17 deep
LR
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885 Connections
W 35x2x30x16x9g with key AS 10x8x56 A, B Service line ports SAE 3/4" 420 bar
50 66 (6000 psi) high pressure series
S Suction port SAE 2" 210 bar
(3000 psi) standard series
80,5
29,6
80,5
M12
M12
32
25,8
80,5
20,8
7/16-14UNC-2B
3/8-16UNC-2B
22 28
30 40
38 48
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
D D
H1/5 LR H2/6 LR
Hydraulic control, pilot pressure related, Electrical control with proportional solenoid,
Pressure cut-off HD1D, HD2D pressure cut-off EP.D (in preparation)
D
HD1/2
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
View Y
anti-clockwise rotation
Vg min
M12; 20 deep
Detail W
Vg max
M10;
17 deep
clockwise rotation
S
DR/D
LR
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885 Connections
W 35x2x30x16x9g with key AS 10x8x56 A, B Service line ports SAE 3/4" 420 bar
50 66 (6000 psi) high pressure series
S Suction port SAE 2" 210 bar
(3000 psi) standard series
29,6
M12
M12
91
35
91
91
91
7/16-14UNC-2B
7/16-14UNC-2B
28 28
40 40
48 48
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
D D
H1/5 LR H2/6 LR
Hydraulic control, pilot pressure related, Electrical control with proportional solenoid,
Pressure cut-off HD1D, HD2D pressure cut-off EP.D
D
HD1/2
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
anti-clockwise rotation
Vg min
M12; 17 deep
Detail W
Vg max
M12;
17 deep clockwise rotation
S
DR/D
LR
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885 Connections
W 40x2x30x18x9g with key AS 12x8x80 A, B Service line ports SAE 1" 420 bar
55 92 (6000 psi) high pressure series
S Suction port SAE 2 1/2" 170 bar
(2500 psi) standard series
34,6
40k6
96
96
30,2
96
96
7/16-14UNC-2B
7/16-14UNC-2B
28 28
40 40
48 48
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
D D
H1/5 LR H2/6 LR
Hydraulic control, pilot pressure related, Electrical control with proportional solenoid,
pressure cut-off HD1D, HD2D pressure cut-off EP.D
D
HD1/2
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
View Y
anti-clockwise rotation
V g min
M16; 24 deep
Detail W
Vg max
M12;
clockwise rotation
17 deep
S
DR/D
LR
Shaft ends
Connections
Z P
A, B Service line ports SAE 1" 420 bar
Splined shaft, DIN 5480 Parallel shaft, DIN 6885
(6000 psi) high pressure series
W 45x2x30x21x9g with key AS 14x9x80
60 90 S Suction port SAE 3" 140 bar
(2000 psi) standard series
T1 Air bleed, tank M26x1,5; 14 deep
T2 Air bleed, tank M26x1,5; 14 deep
39,6
101
M16
M16
45
101
R 2,5
101
36
5/8-11 UNC-2B
36
55
67
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
D D
H1/5 LR H2/6 LR
Hydraulic control, pilot pressure related, Electrical control with proportional solenoid,
pressure cut-off HD1D, HD2D pressure cut-off EP.D
D
HD1/2
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
anti-clockwise rotation
V g min
M16; 24 deep
Detail W
Vg max
M12;
17 deep clockwise rotation
S
DR/D
LR
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885
W 50x2x30x24x9g with key AS 14x9x80 Connections
65 90 A, B Service line ports (without impeller) SAE 1" 420 bar
(6000 psi) high pressure series
A, B Service line ports (with impeller) SAE 1 1/4" 420 bar
(6000 psi) high pressure series
44,6
106
M16
M16
50
106
36
36
55
67
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
D D
H1/5 LR H2/6 LR
Hydraulic control, pilot pressure related, Design A11VLO (with charge pump, clockwise rotation)
pressure cut-off HD1D, HD2D connections see page 22
66,7
32
31,8
D
HD1/2
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
66
224,5
Y W
79,4
B
38
B S
165
Vg max M1 R M
15,9 R 36,5 224,5
272,5 262,5
319,3 (S)
Detail W
S
T2 X
S
120,7
116 (S)
90
DR/D S
LR
T1 M B G
381,3
395,3
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885
W 50x2x30x24x9g with key AS 16x10x100
65 113
126
44,6
M20
55m6
126
M16
36
42
44
55 105 Connections
A, B Service line ports SAE 1 1/2" 420 bar
S T (6000 psi) high pressure series
Splined shaft SAE D, 13/4" Splined shaft SAE F, 2" S Suction port SAE 3 1/2" 35 bar
pressure angle 30, 13T-8/16 pitch pressure angle 30, 15T-8/16 pitch
flat root, side fit flat root, side fit (500 psi) standard series
tolerance class 5, ANSI
4
B92.1a/1976 tolerance class 5, ANSI B92.1a/1976 T1 Air bleed, tank M33x2; 16 deep
75 88 T2 Air bleed, tank M33x2; 16 deep
M1 Gauge point positioning chamber M12x1,5; 12 deep
R4
M Gauge point for pressure port M12x1,5; 12 deep
R 2,5
X Port for p-control M14x1,5; 12 deep
42,3
126
126
36
5/8-11UNC-2B
36
R Air bleed, Oil drain M33x2; 16 deep
36
G Control pressure port M14x1,5; 12 deep
55 66 at design with stroke limiter (H.., U2), or HD, EP-control with fitting GE10 - PLM
67 80 (in other case is port "G" closed)
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
227,5
R M1
379
T2 S
Y D
H1/5 LR
T1 M B G
Hydraulic control, pilot pressure related, Design A11VO 190 (without charge pump, clockwise
pressure cut-off HD1D, HD2D rotation), electrical control EP, connections see page 24
346,8
340,8
281,3
T1 M G
R M1
T2 S
T1 M B G
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
M16; 21 deep
B S
165,1 (SAE E)
72
W
224,5
B Y
79,4
38
174
Vg max M
15,9 36,5
R M
R 224,5
307 262,5
307
S Detail W
T2
132,5
120,7
130
90
EP S
M16; 21 deep
69,9
130
372 T1 M B G
Shaft ends
Z P
Splined shaft, DIN 5480 Parallel shaft, DIN 6885
W 60x2x30x28x9g with key AS 18x11x100
66 113
54,6
M20
M20
60m6
130
130
42 42
Connections
47 105
A, B Service line ports SAE 1 1/2" 420 bar
58 (6000 psi) high pressure series
S T S Suction port (without charge pump) SAE 3 1/2" 35 bar
Splined shaft SAE D, 1 /4" 3 Splined shaft SAE 21/4" (500 psi) standard series
pressure angle 30, 13T-8/16 pitch pressure angle 30, 17T-8/16 pitch S Suction port (with charge pump) SAE 4" 35 bar
flat root, side fit flat root, side fit (500 psi) standard series
tolerance class 5, ANSI B92.1a/1976 tolerance class 5, ANSI B92.1a/1976
T1 Air bleed, tank M33x2; 16 deep
75 88 T2 Air bleed, tank M33x2; 16 deep
M1 Gauge point positioning chamber M12x1,5; 12 deep
R 2,5 R4
M Gauge point for pressure port M12x1,5; 12 deep
48,6
130
X M14x1,5; 12 deep
Y Pilot pressure port M14x1,5; 12 deep
5/8-11UNC-2B
3/4-10UNC-2B
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
Hydraulic control, pilot pressure related, Design A11VLO 260 (with charge pump, clockwise
pressure cut-off HD1D, HD2D rotation), electrical control EP, connections see page 26
T1 M G
15,9 R 304 M
414
346
T2 S
T1 M B G
428
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
82,55 (SAE A)
130 339
130*
190
190* 394
260 385
260* 427,3
*) design with charge pump (impeller)
106,4
A1
130 tobis
mounting flange
Anbauflansch
190
190* 400 400 400
260 391,5 391,5 391,5
260* 433,5 433,5 433,5
*) design with charge pump (impeller)
181
213 A1
to mounting flange
bis Anbauflansch
Variable Displacement Pump A11VO Prior to finalising your design, please obtain a certified drawing.
152,4 (SAE D)
size 75
95 317
130 340 340 340 340
130*
190
190*
260
161,6 A1 260*
200 bis Anbauflansch
to mounting flange *) design with charge pump (impeller)
224,5 A1
bismounting
to Anbauflansch
flange
Input Drive
Permissible axial and radial loading on drive shaft
Size 40 60 75 95 130 190 260
distance of Fq a mm 17,5 17,5 20 20 22,5 26 29
(from shaft collar) b mm 30 30 35 35 40 46 50
c mm 42,5 42,5 50 50 57,5 66 71
max. perm. radial load at distance a Fq max N 3600 5000 6300 8000 11 000 16 925 22 000
b Fq max N 2891 4046 4950 6334 8594 13 225 16 809
c Fq max N 2416 3398 4077 5242 7051 10 850 13 600
max. perm. axial load Fax max N 1500 2200 2750 3500 4800 6000 4150
flange
A11VO130LRDS/10R-PZD12K61
+
A11VO60LRDS/10R-PZC12N00
shaft end S TE perm. Nm 314 (SAE B-B) 602 (SAE C) 602 (SAE C) 1640 (SAE D)
SAE (ANSI B92.1a-1976) (W1"-15T 16/32DP) (W11/4"-14T 12/24DP) (W11/4"-14T 12/24DP) (W13/4"-13T 8/16DP)
shaft end T TE perm. Nm 602 (SAE C) 970 970
SAE (ANSI B92.1a-1976) (W11/4"-14T 12/24DP) (W13/8"-21T 16/32DP) (W13/8"-21T 16/32DP)
Max. perm. through drive torque 3) TD perm. Nm 314 521 660 822
Code explanations
TD perm. = max permissible through drive torque in Nm
TE perm. = max. permissible input torque at the drive shaft in Nm
1,59 V g1 p1
T1 = take off torque at the 1st pump = in Nm
100 mh
1,59 V g2 p2
T2 = take off torque at the 2nd pump = in Nm
100 mh
Vg1 = pump displacement per rev. 1st pump in cm3
Vg2 = pump displacement per rev. 2nd pump in cm3
p1 = differential pressure 1st pump in bar
p2 = differential pressure 2nd pump in bar
mh = mechanical-hydraulic efficiency
Combination pump
Single pump T1 T2
T1
TE
TE 1. Pumpe
1. Pumpe
1st pump 2nd
2. pump
Pumpe
Pumpe
TD TD
Brueninghaus Hydromatik 31/32
RE 92500/03.97
Vorzugstypen A6VM
Preferred Types, please state type and ident-no. when ordering
Type Ident-No. Type Ident-No.
A11VO95LRS/10R-NSD12N00 9609834
A11VO95LRS/10R-NPD12N00 9609835
A11VO95LRS/10R-NSD12K01 9609836
A11VO95LRS/10R-NPD12K01 9609837
A11VO95LRH2/10R-NSD12N00 9609838
A11VO95LRH2/10R-NPD12N00 9609839
A11VO95LRH2/10R-NSD12K01 9609840
A11VO95LRH2/10R-NPD12K01 9609841
A11VO95DRS/10R-NSD12N00 9609842
A11VO95DRS/10R-NPD12N00 9608484
A11VO95DRS/10R-NSD12K01 9609844
A11VO95DRS/10R-NPD12K01 9609845
A11VO130LRS/10R-NSD12N00 9609848
A11VO130LRS/10R-NPD12N00 9609646
A11VO130LRS/10R-NSD12K02 9609850
A11VO130LRS/10R-NPD12K02 9609851
A11VO130LRH2/10R-NSD12N00 9609852
A11VO130LRH2/10R-NPD12N00 9609853
A11VO130LRH2/10R-NSD12K02 9609854
A11VO130LRH2/10R-NPD12K02 9609855
A11VO130DRS/10R-NSD12N00 9601036
A11VO130DRS/10R-NPD12N00 9609857
A11VO130DRS/10R-NSD12K02 9609858
A11VO130DRS/10R-NPD12K02 9609859
Brueninghaus Hydromatik GmbH, Plant Elchingen, Glockeraustrae 2, D89275 Elchingen, Tel. (07308) 820, Telex 712538, Telefax (07308) 7274
32/32 Brueninghaus Hydromatik The specified data is for product description purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the contract. All rights reserved Subject to revision