Phontech Bts 4000
Phontech Bts 4000
Phontech Bts 4000
1/52
DOCUMENTATION HANDBOOK
PHONTECH
BTS 4000
BATTERYLESS TELEPHONE SYSTEM
www.jotron.com
Ver 2010.09
Doc.No.: 08400-006-DE
Contents:
1. GENERAL DESCRIPTION ............................................................................................................. 3
2. LIST OF TELEPHONE UNITS ....................................................................................................... 4
2.1. 24 LINES BATTERYLESS TELEPHONE, TYPE 4040 ......................................................... 4
2.2. 12 LINES BATTERYLESS TELEPHONE WITH INTEGRATED AMP, TYPE 4061 .......... 5
3. ADDITIONAL EQUIPMENT .......................................................................................................... 6
3.1. AMPLIFIER UNIT, TYPE 4000 ............................................................................................... 6
3.2. RELAY UNIT, TYPE 9000 ...................................................................................................... 7
3.3. PLUGBOX FOR HEADSET WITH CALL STOP, TYPE 4018 .............................................. 7
3.4. HEADSET WITH PTT SWITCH AND PLUG, TYPE 0018 ................................................... 8
3.5. HEADSET WITH PTT SWITCH, TYPE 9010 ........................................................................ 8
3.6. PLUG-IN RELAY MODULE (BRD 99400-011) .................................................................... 9
4. LIST OF FACILITIES ...................................................................................................................... 9
4.1. BATTERYLESS AMPLIFIERT UNIT, TYPE 4000 ............................................................... 9
4.2. 24 LINES BATTERYLESS TELEPHONE 4040 ................................................................... 10
4.3. SINGLE LINE BATTERYLESS TELEPHONE, TYPE 4050 ............................................... 10
4.4. SINGLE LINE BATTERYLESS TELEPHONE WITH AMPLIFIER, TYPE 4051.............. 10
4.5. 12 LINES BATTERYLESS TELEPHONE, TYPE 4060 ....................................................... 10
5. BASIC MEANS OF OPERATION ................................................................................................ 11
5.1. GENERAL ............................................................................................................................... 11
5.2. MAKE A CALL TO ANOTHER STATION .......................................................................... 11
5.3. ANSWER A CALL FROM ANOTHER STATION............................................................... 11
5.4. TERMINATE A CONVERSATION ...................................................................................... 11
5.5. HEADSET (TYPE 9010) OPERATION ................................................................................. 12
1 08.07.2010 REVISION, EM 1289 ASK ASK This document is the property of JOTRON
PHONTECH and must not be copied or shown to a
0 27.10.2008 FINAL DOCUMENTATION CD third person without our written consent. In the
REV No: ISSUE DATE REASON FOR ISSUE PREPARED CHECKED APPROVED interest of product improvement, JOTRON
PHONTECH reserves the right to alter
TITLE: BATTERYLESS TELEPHONE SYSTEM 4000 specification and design without notice.
Page 1 of 19
Doc.No.: 0400-000-DE
5.5.1. Make a call out from the telephone to another station ......................................................... 12
5.5.2. Answer a call from another station ...................................................................................... 12
6. INSTALLATION............................................................................................................................ 13
6.1. SYSTEM CONFIGURATION ................................................................................................ 13
6.2. MOUNTING............................................................................................................................ 13
6.3. COMPASS SAFE DISTANCE ............................................................................................... 13
6.4. CABLE TERMINATION ....................................................................................................... 13
6.5. CABLE REQUIREMENTS .................................................................................................... 14
6.6. GLANDING ............................................................................................................................ 14
6.7. SCREENING ........................................................................................................................... 14
6.8. MARKING .............................................................................................................................. 14
6.9. FASTENING ........................................................................................................................... 14
6.10. PRESERVATION ................................................................................................................ 14
6.11. VOLUME ADJUSTMENT ................................................................................................. 15
7. TECHNICAL DATA. TELEPHONE UNITS 4040/4050/4051/4060/4061................................... 16
8. SINGLE LINE DIAGRAM SINGLE LINE SYSTEM ............................................................... 17
9. SINGLE LINE DIAGRAM 12 LINE SYSTEM ......................................................................... 18
10. SINGLE LINE DIAGRAM 24 LINE SYSTEM ...................................................................... 19
Page 2 of 19
Doc.No.: 08400-006-DE
1. GENERAL DESCRIPTION
The batteryless telephone system is developed and manufactured Jotron Phontech as.
The different modules in the system are designed to meet the need and demand for non-
powered internal (sound powered) emergency communication on ships.
The system is basically divided into three different configurations, the single line system
(4050/4051) for point-to point communication between two stations, like the bridge and the
machinery spaces. The 12 lines system, (4060/4061) for up to 12 stations. And the 24 lines
system (4000/4040) for up to 24 stations.
The compact design provides good installation possibilities, with a minimum space
requirement.
The flush mounting units are adapted to the DIN 144x144 module standard for easy mounting
in the bridge and engine control consoles.
The modules may also be wall mounted; this requires a wall mounting back-box. (Optional)
The different units are prepared for gland mounting, i.e. holes have been fitted for a wide range
of cable glands.
Several additional types of equipment may be connected to the Batteryless Telephone System,
like headset connector boxes, extra headsets, power supplies, external signal devices relay
switch boxes, etc.
Page 3 of 19
Doc.No.: 08400-006-DE
PHONTECH 4040
Page 4 of 19
.
Doc.No.: 08400-006-DE
PHONTECH 4061
Page 5 of 19
.
Doc.No.: 08400-006-DE
3. ADDITIONAL EQUIPMENT
Type BTS 4000. Amplifier unit (separate) for a 4040 / 24 lines system
Type 9000 Relay unit (for additional signal device)
Type 4018 Plugbox for headset with Call stop.
Type 0018 Headset with PTT switch and plug. (Connects to 4018)
Type 9010 Headset with PTT switch. (Connects directly to the telephone unit)
BRD 99400-011 Plug-in relay module for external signal device.
Type 4052 Junction box type I (12 ext.)
Type 4053 Junction box type II (8 ext.)
Page 6 of 19
.
Doc.No.: 08400-006-DE
Page 7 of 19
.
Doc.No.: 08400-006-DE
9 meter CABLE
Page 8 of 19
.
Doc.No.: 08400-006-DE
A relay module for activation of external signal device can be installed in the betteryless
telephones: 4040 / 4050 / 4051 / 4060 / 4061
The relay module is to be mounted by the installer. The unit is delivered separately, and is to be
plugged into the appropriate telephone unit.
4. LIST OF FACILITIES
Page 9 of 19
.
Doc.No.: 08400-006-DE
Page 10 of 19
.
Doc.No.: 08400-006-DE
5.1. GENERAL
The batteryless telephone system is operated by means of the handset with PTT switch,
the call line selector switch, (not 4050/4051) and the call generator crank.
There is no priority between units in the system and several users can use the system
simultaneously. All users will then join the same conversation/conference call.
The units are equipped with screw terminals for connection of a headset, type 9010.
- The telephone will sound the call tone and light the call indicator led (red)
- Lift the handset (See illustration next page) and press the PTT button.
Keep the PTT button pressed at all times during conversation.
- Optional headset: Set the PTT switch to ON and answer the call.
- If external power is connected to the system, the call delay timer will keep the call
indicator led lit (green) for about 30 seconds. Press the CALL STOP button (on the
telephone or the headset plugbox, type 4018) to turn it off manually before automatic
time out.
- Additional external signal devices will be activated together with the call indicator led.
Page 11 of 19
.
Doc.No.: 08400-006-DE
Page 12 of 19
.
Doc.No.: 08400-006-DE
6. INSTALLATION
6.2. MOUNTING
The telephone units (all types) are delivered for flush mounting. Optional wall mounting boxes
are delivered upon request.
Jotron Phontech as highly recommends the use of junction boxes for the external cable
distribution.
Prepared junction boxes, type 4052 and 4053 are available.
The sub-units (4000/4018/9000) are delivered with wall mounting box as standard.
All terminations must be done according to the External Cabling diagrams (example). Ref
chapter 6.1 above.
Page 13 of 19
.
Doc.No.: 08400-006-DE
All cables used with the Batteryless Telephone System to be of approved ship cable type.
ESPECIALLY IMPORTANT:
6.6. GLANDING
The cables enter the units by means of cable glands. Where cable glands are not supplied from
the factory, the installer must adapt the glands to the actual cable outer diameter. This is to
obtain the specified ingress protection and cable relief.
6.7. SCREENING
The cable screen must be terminated to the ships GND in the main unit (4051/4061). The
cable screen must be connected through the junction box(s) and terminated in terminal 21
(terminal 35 in 4040) or earth stud in all telephones. Ref chapter 6.1 above.
6.8. MARKING
6.9. FASTENING
Where applicable, the cables and the conductors shall be strapped to the structure.
6.10. PRESERVATION
Prior to, during, and after completion of the installation the equipment surfaces to be protected
against acid holding fluids, pollution, moist, impacts etc.
Page 14 of 19
.
Doc.No.: 08400-006-DE
This in order to avoid damaged equipment for which Jotron Phontech will void warranty
claims.
Please note that volume adjustment is preset to a normal environment. It is not possible to make
individual volume adjustments on the telephones, but there is a common volume adjustment for
the whole system.
This is located in the system amplifier either as trimming potentiometer R12 in the 4000 unit or
RV1 in the 4051/4061 units.
Page 15 of 19
.
Doc.No.: 08400-006-DE
Technical data for substations etc. see data sheets for each unit.
Page 16 of 19
.
Doc.No.: 08400-006-DE
Page 17 of 19
.
Doc.No.: 08400-006-DE
4018
H EADSET CALL
STOP
Page 18 of 19
.
Doc.No.: 08400-006-DE
4018
H EA D SET CALL
STOP
Page 19 of 19
.
Doc.No.: 99400-011-CA
The Batteryless Telephone Board 99400-001 is designed and produced by Jotron Phontech AS.
The board is a plug-in module supporting switching facility for external signal device in the batteryless
telephone system.
The Relay board is compatible with BTS telephone types 4040 (Ver 05827), 4050, 4051, 4060 and
4061.
Switching capacity:
24 VDC: 150 VA
115 VAC: 700 VA
220 VAC: 1500 VA
Operation voltage:
Page 1 of 1
www.jotron.com