GECC3000 A P P L I C A T I O N
The DC voltage power supply models GECC3000/1500
Powerful output up 3.3 KW
are designed for supplying the DC voltage and current
Lightweight: only 25 kg for the testing of:
GECC3000 GECC1500
RANGE CURRENT A
1 0...27 0...13,5
2 0...13,5 0...6,5
101
GECC3000-GECC1500
Output adjustment: by two potentiometers, one for the voltage Accessories supplied with the unit
and one for the overload current. Power supply cable.
Output power: GECC3000: 3.3 kW Output connectors.
GECC1500: 1,65 kW. Operating manuals.
Service: continuous duty.
Output ripple: less than 1% with no load, and 2.5% at full load. APPLICABLE STANDARDS
Temperature coefficient: greater than 100 ppm/C.
Load stability: better than 2% between unloaded and Electromagnetic compatibility
maximum load. Directive no. 89/336/CEE dated May 3, 1989, modified by the
Yeld, at full power: better than 80%. directive 92/31/CEE dated May 5, 1992.
Applicable Standards:
Measurement EN 50081-2; EN 50082-2; EN 55011;EN 61000-3-3;
Two large LED meters: EN 50082-2; ENV 50140; ENV 50141; ENV 50204;
. Voltage: 3 digit digital instrument, full scale 999 V; IEC 1000-4-2; IEC1000-4-4; IEC 1000-4-6; IEC 1000-4-8.
. Current: 3 digit digital instrument, full scale 99.9 A.
Accuracy: 1% of the measurement 0.1% of the selected Low voltage directive
range. Directive n. 73/23/CEE, modified by the directive 93/68/CEE.
Applicable standards, for a class I instrument, pollution degree
Connections 2, installation category II: CEI EN 61010-1.
Output connection: by connector. In particular:
Mains connection: by a two meter cable connected to the . Operating temperature: 0 - 45C; storage: -25C to 70C.
instrument via a plug. . Relative humidity: 10 - 80% without condensing.
Protections
Fuse on mains supply.
Filter on mains supply.
Soft-start electronic circuit.
Protection for start under load, with internal logic to stabilize
the sequence depending upon the capacitor charge.
Electronic protection for the output in a short circuit condition.
Protection for maximum current, adjustable by potentiometer.
Indication light in case of overload.
Thermal protection.
Indication light in case of over-temperature.