LUBRIZOL TEST PROCEDURE

TP-AATM-102B-a
Edition: October 13, 2006
Previous Edition: November 1, 1996

Specific Gravity- Pycnometer Method


DEFINITION 2. Warm to the specified temperature using the
warmth of your hand. Wipe off the overflow,
This method determines the ratio of the weight of a cap the bottle; clean, dry and weigh.
unit volume of the sample at a specified temperature
to the weight of a unit volume of water at the same 3. Calculate the specific gravity as directed
temperature. below.

SCOPE CALCULATION
Applicable to all oils and liquid fats and solvents. A. Specific gravity at specified temperature =

APPARATUS Weight of bottle and sample - weight of bottle


Weight of water at temperature
1. Specific gravity bottles with well fitting ground
glass joints, 25 ml. capacity. Calibrate these B. Specific gravity at 60/25C =
bottles as follows: Clean and dry thoroughly and
then fill with recently boiled and cooled deionized F
water at 1-3C below specified temperature. Fill W[1+(0.000025X35)]
the bottle to overflowing by holding the bottle on
its side in such a manner as to prevent the
entrapment of air bubbles. Warm to 25C using F = weight of sample at 60C.
the warmth of your hand. Wipe off the overflow; W = weight of water at 25C.
clean, dry and cap the bottle when 25C is
reached; weigh.
2. Thermometer of suitable range with 0.1 or 0.2
subdivisions. Pre-standardized by comparison
with a thermometer calibrated by the U.S. Bureau
of Standards.

PROCEDURE
1. Cool the sample to approximately 1-3C below
specified temperature and fill the bottle to
overflowing, holding the bottle on its side in such
a manner as to prevent the entrapment of air
bubbles.

Lubrizol Advanced Materials, Inc. / 9911 Brecksville Road, Cleveland, Ohio 44141-3247 / TEL: 800.379.5389 or 216.447.5000
The information contained herein is being furnished for combination with other substances or in the Users THE IMPLIED WARRANTIES OF MERCHANTABILITY
informational purposes only, upon the express condition process. Due to variations in methods, conditions and OR FITNESS FOR A PARTICULAR PURPOSE.
that the User makes its own assessment of the equipment used commercially in processing these It is the Users sole responsibility to determine if
appropriate use of such information. While the information materials, no warranties or guarantees are made as there are any issues relating to patent infringement of any
contained herein is believed to be reliable, no representations, to the suitability of the information or products for the component or combination of components relating
guarantees or warranties of any kind are made as to its applications disclosed. Lubrizol shall not be liable to the supplied information. Nothing contained herein is
accuracy, suitability for a particular application or the and the User assumes all risk and responsibility for any to be considered as permission, recommendation,
results to be obtained herefrom. Lubrizol Advanced use or handling of any material beyond Lubrizol's direct nor as an inducement to practice any patented
Materials, Inc. ("Lubrizol") cannot guarantee how any control. LUBRIZOL MAKES NO WARRANTIES, EXPRESS invention without permission of the patent owner.
products associated with this information will perform in OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
For further information, please visit: www.lubrizol.com/personalcare