Install Help
Install Help
Install Help
Release 16.2
August 2015
Copyright and Trademark Information
2015 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT,
HFSS, AIM and any and all ANSYS, Inc. brand, product, service and feature names, logos and slogans
are registered trademarks or trademarks of ANSYS, Inc. or its subsidiaries in the United States or other
countries. ICEM CFD is a trademark used by ANSYS, Inc. under license. CFX is a trademark of Sony Cor-
poration in Japan. All other brand, product, service and feature names or trademarks are the property
of their respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND
ARE CONFIDENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS.
The software products and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates
under a software license agreement that contains provisions concerning non-disclosure, copying, length
and nature of use, compliance with exporting laws, warranties, disclaimers, limitations of liability, and
remedies, and other provisions. The software products and documentation may be used, disclosed,
transferred, or copied only in accordance with the terms and conditions of that software license
agreement.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement,
the use, duplication, or disclosure by the United States Government is subject to restrictions stated in
the ANSYS, Inc. software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary
software and third-party software. If you are unable to access the Legal Notice, please contact ANSYS,
Inc.
The information in this guide applies to all ANSYS, Inc. products released on or after this date, until superseded
by a newer version of this guide.
2015 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT, HFSS, AIM
and any and all ANSYS, Inc. brand, product, service and feature names, logos and slogans are registered trademarks
or trademarks of ANSYS, Inc. or its subsidiaries in the United States or other countries. ICEM CFD is a trademark
used by ANSYS, Inc. under license. CFX is a trademark of Sony Corporation in Japan. All other brand, product,
service and feature names or trademarks are the property of their respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
ANSYS, Inc. Licensing Guide
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS, Inc. Licensing Guide
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
List of Tables
1.1. FlexNet Versions ..................................................................................................................................... 2
1.2. Identifying License Files .......................................................................................................................... 7
2.1. Configuring TCP/IP ................................................................................................................................ 12
2.2. License Manager Automatic Startup Instructions ................................................................................... 21
2.3. Removing License Manager Automatic Startup Instructions ................................................................... 21
2.4.Tomcat Automatic Startup Instructions .................................................................................................. 22
2.5. Removing Tomcat Automatic Startup Instructions ................................................................................. 23
6.1. 64-bit Windows Support ....................................................................................................................... 72
6.2. 64-bit Linux Support ............................................................................................................................. 72
6.3. 64-bit Windows File Information ............................................................................................................ 72
6.4. 64-bit Linux File Information ................................................................................................................. 72
8.1. Product/Feature Names for Licensed Products ....................................................................................... 99
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. vii
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
viii of ANSYS, Inc. and its subsidiaries and affiliates.
Preface
This document contains information for running the ANSYS, Inc. License Manager with all ANSYS, Inc.
products, including ANSYS Electromagnetics (Ansoft) products. However, some information may pertain
only to specific products/licensing levels, such as Mechanical APDL (ANSYS) or ANSYS Fluent.
For specific operating system requirements, refer to the installation guide for the product and platform
you are running. See our platform support information at http://www.ansys.com/Support/Platform+Sup-
port. (This URL is case-sensitive.)
Intended Audience
The ANSYS Licensing Guide is intended for the person responsible for licensing administration of all
ANSYS, Inc. products at a site. This person is typically the system administrator. End users of the product
may also find this information useful, especially client options.
Applicability
This guide applies to all products licensed with the ANSYS License Manager. See Product Variable
Table (p. 99) for a list of products.
After installing release 16.1 or 16.2 of the ANSYS License Manager, please clear your default browser cache
before using ANSYS License Management Center for the first time to ensure that all ANSYS License
Management Center options are available to you.
As of release 16.1, the ANSYS License Management Center now includes an option to reread the license
manager settings. The Product Order file has been updated.
As of release 16.2, a new version of the FlexNet Publisher (FNP) 11.13.0.2 has been incorporated into the
ANSYS License Manager.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. ix
Preface
Lengthy user input lines that exceed the width of the page are listed in multiple lines, with the second
and subsequent lines indented:
exec_path <drive>:\Program Files\ANSYS Inc\ansys162\ac4
\bin\pro\<platform>\ac4pro162.exe
Note
Note paragraphs are introduced by the text Note. A note contains information that supple-
ments the main topic being discussed.
Caution
Paragraphs that begin with the word Caution in bold, with the rest of the text in normal
type, warn you about actions or situations that potentially may cause problems or unexpected
behavior or results in ANSYS, Inc. products.
Warning
Paragraphs that begin with the word Warning in bold warn you about actions or situations
that can shut down ANSYS, Inc. products, damage files, etc.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
x of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 1: Introduction
ANSYS, Inc. uses the FlexNet license manager for all of its licensed products. FlexNet is best known for
its ability to allow software licenses to be available (or float) anywhere on a network. Floating licensing
benefits both users and license administrators. Users can make more efficient use of fewer licenses by
sharing them on the network. License administrators can control who uses the licensed application and
the machine(s) where the licenses will be available. The format of the traffic between the ANSYS
product(s) and the license manager is machine-independent, allowing for heterogeneous networks. The
license server machine and the computer running an application can be different hardware platforms
or even different operating systems (Windows and Linux, for example).
The actual communication between the ANSYS applications and FlexNet occurs through an intermediary
process called the ANSYS Licensing Interconnect. The Licensing Interconnect is nearly transparent; you
should not see any noticeable difference in your day-to-day operation of ANSYS products.
To get the full set of files necessary to run as a server, you will need to run the license manager install-
ation. The general licensing process is explained here; for detailed installation instructions, see Installing
the ANSYS License Manager (p. 11). All files necessary to run as a client are automatically installed
during the product installation.
License administration functions are performed via the ANSYS License Management Center and the
ANSLIC_ADMIN utility (server and client). For more information on the using these tools, seeLicense
Server Administration Using ANSYS License Management Center (p. 31) and Using the ANSLIC_ADMIN
Utility (p. 57).
1. Select the license server machine(s). See Selecting License Server Machines (p. 8) for guidelines.
2. Install and configure TCP/IP. See Communications Requirements (p. 12) for information on configuring
TCP/IP.
3. Install the software. See Installing the License Manager (p. 13), or see the appropriate installation
manual for your product and platforms for detailed installation instructions.
4. After you receive your license file, add your license file using the ANSYS License Management Center.
See Adding a License with the ANSYS License Management Center (p. 32)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Introduction
The ANSYS License Manager can run on the same server as other FlexNet license managers with no
intervention or special configuration requirements. However, the ANSYS License Manager does not
support the use or combination of license files from other vendors.
Links to FlexNet
For more information on using FlexNet, visit the FlexNet web site at http://www.flexerasoftware.com/.
You can refer to the FlexNet License Administration Guide for more detailed information on all FlexNet
features. You can access this document from the ANSYS License Management Center.
License files
The ANSYS, Inc. License Manager monitors what products are being run, who is running them, and from
what computer system. It grants or denies permission to run products. When an ANSYS product begins,
it requests permission to execute from a license server. The ANSYS, Inc. License Manager checks the
pool of available licenses and grants the request only if the required licenses are available. For each
request that is granted, the licenses are removed from the pool. As each product execution ends, its
licenses are returned to the pool.
lmgrd must be running on the license server machine to run ANSYS, Inc. products.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
Explanation of Licensing Terms
Client programs, including ansysli_server, communicate with ansyslmd, usually through TCP/IP
network communications. The vendor daemon (ansyslmd) is started by lmgrd. The vendor daemon
ansyslmd must be running on the license server machine to run ANSYS, Inc. products.
With the Licensing Interconnect, your license file and license options file are still applicable and in effect.
Using an intermediary process allows us to seamlessly integrate our full range of product offerings to
continually offer you access to the latest products with minimal disruption to your licensing environment.
It also allows us a platform on which to enhance important licensing features.
The Licensing Interconnect must be running on the license server machine to run ANSYS, Inc. products.
You can modify only these data items in the license file:
Optional port numbers on the VENDOR line(s) (for firewall support only)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
Introduction
Long lines normally use the "\" line-continuation character to break up long lines. A space character
must precede the line-continuation character.
Note
Everything else is used to compute the license key and should be entered exactly as supplied.
All data in the license file is case sensitive, unless otherwise indicated.
where:
host is the license server machine host name or IP address; a string returned by the Linux hostname
or uname -n command. On Windows systems, ipconfig /all returns the host name. This can also
be an IP address (nnn.nnn.nnn.nnn format).
hostid is returned by the Get System Hostid Information option of the ANSYS License Management
Center.
1055 is the ANSYS default port number for FlexNet TCP. If port 1055 is already in use on your system,
you can change this value.
Example:
SERVER enterprise 0122345 1055
Note
If you change the FlexNet port number, then you must also change the FlexNet port number
that is specified in the ansyslmd.ini file (see Specify the License Server Machine (p. 59))
or in the ANSYSLMD_LICENSE_FILE environment variable on all client machines to match
the port number specified in the SERVER line.
where:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
Explanation of Licensing Terms
vendor_daemon_path is the path to the executable for this daemon. This path is optional. ANSYS,
Inc. does not supply this field because lmgrd will look for the vendor daemon ansyslmd executable
in the directory where lmgrd is located and all ANSYS products install both of these daemons into the
same directory.
Note
If you do supply this path and the path includes spaces, enclose the entire directory path in
double quotes, as in the following example:
VENDOR ansyslmd "C:\Program Files\ANSYS Inc\Shared Files\Licensing
\win64"
options_file_path is the full path to the end-user options file for this daemon. FlexNet does not
require an options file. The options file need not be specified on this line. As long as the options file
ansyslmd.opt is located in the same directory as the license file (the license_files directory), the
vendor daemon will automatically find and use it.
If the directory path includes spaces, enclose the entire directory path in double quotes, as in the fol-
lowing example:
VENDOR ansyslmd options="C:\Program Files\ANSYS Inc\Shared Files\
Licensing\ansyslmd.opt"
port is the vendor daemon port number. Note: This is for firewall support only and is otherwise not re-
commended. In the following example, #### would be replaced with the port number you choose:
VENDOR ansyslmd options=/ansys_inc/shared_files/licensing
/ansyslmd.opt port=####
where:
ansyslmd is the name of the ANSYS vendor daemon; also found in the VENDOR line. The specified
daemon serves this feature.
feat_version is the latest build date of this feature that is supported by this license. For paid-up
customers, this is usually set to the expiration date of the maintenance agreement. The value of 9999.9999
is used when this field is not applicable.
Additional fields may follow. See the FlexNet License Administration Guide (accessible from the ANSYS
License Management Center) for more information. Note that ANSYS, Inc. may not support all options
described in the FlexNet License Administration Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
Introduction
VENDOR_STRING Keywords ANSYS, Inc. has created the following VENDOR_STRING keywords:
customer
The customer keyword specifies the customer number. The format is customer:<cust_num>,
where cust_num is the customer's number. You must not modify this keyword.
The SIGN2 keyword specifies the Tamper Resistant License (TRL) encryption. The encryption is 60
characters (fifteen 4 character segments separated by spaces).
where:
ansys is the feature representing ANSYS Mechanical and acfd is the feature representing ANSYS CFD.
9999.9999 indicates that the maintenance agreement is not applicable. Otherwise, this the highest
supported build date for the product. For Mechanical APDL (ANSYS) only, you can view the build date
by running Mechanical APDL (ANSYS) with the -v command option.
15 and 12 are the number of tasks for ANSYS Mechanical and ANSYS CFD, respectively
8C59A481BA50 and 47A354CA1291 are encryption keys for ANSYS Mechanical and ANSYS CFD, respectively
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
Explanation of Licensing Terms
In the line beginning with the word VENDOR, the next field/item is ansyslmd.
In the line(s) beginning with the word INCREMENT, the third field/item is ansyslmd.
Through use of the FlexNet Common Vendor Daemon technology, license files using the ansoftd vendor
daemon are also supported by the ANSYS License Manager.
ANSYS, Inc. supplies some licenses for other applications that use different license managers. These license
files are not compatible with the ANSYS License Manager. The applications and how to recognize their
license files are explained below. Look for the words shown in the VENDOR, DAEMON, INCREMENT, and
FEATURE lines for each application. For these license files, you must use their respective license manager
tools.
The server machine or machines are designated by you--the end user. You have the option of designating
one server or three servers. In a one-server network, if the server machine goes down, the licenses are
no longer available for use until the server machine is back in service. In a three-server (redundant triad)
network, as long as two of the three machines are still running, the licenses are still available for use.
The master server actually controls the license administration. If a network has only one server machine,
then that server machine is automatically the master server. In a three server environment, the order
of the SERVER lines in the license file determines which server is the master. The order of the servers
must match on all machines in a three server environment. The first is the master, the second is the first
backup, etc. If the order of the SERVER lines does not match on the three servers, then the servers will
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
Introduction
attempt to determine the master server; however, this attempt may not be successful. In a three-server
network, if the master server is unavailable, then the first backup acts as the master.
You must make sure the order of the SERVER lines is consistent between redundant servers; otherwise,
reconnections may fail.
You need to select the computer systems that will act as server machines before we can supply you
with the licenses that are required to activate your licensed product(s). Information about the server
machines is used to generate the necessary license key(s).
Consider the following points when deciding which computer(s) will be used as server(s):
All files used in conjunction with the license manager software must be located on a disk that is physically
local to the server computer(s).
Computers that experience extremely high levels of network traffic or processing lags due to high CPU
and/or I/O usage are poor candidates for servers.
Do not enable sleep mode for the computer you are using as a license server. Client computers are not
able to connect with a license server that is in sleep mode.
We do not allow the use of wide area networks (WANs) for license servers (with the standard ANSYS contract).
If using a three-server network, we recommend that you choose three machines that are of the same platform
type (that is, three Linux, three Windows machines, etc.).
If using a three-server network, we highly recommend that all three server machines be on the same subnet
in the same physical location.
If these guidelines are not followed, the ability of the ANSYS License Manager to perform consistently
will be compromised.
Caution
Do not change the date on the license server machine. Doing so will prohibit the ANSYS
product from running. Restoring the system to its original state prior to the date change
may require significant effort.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
Explanation of Licensing Terms
Any number of license server machines can be running independently. The total number of licenses is
split between each license server. For example, if you are licensed for 20 tasks of a certain product, and
you have two license server machines, each license server machine will serve ten licenses. In this example,
if one of these machines fails, only ten licenses will be available.
Three different machines can be selected to work together in tandem, where two of the three must be
running at all times. These three license server machines work from a single set of licenses. This option
is not recommended.
We recommend the first option if your site requires redundancy. Be sure to review Selecting License
Server Machines (p. 8) for guidelines and special considerations when choosing license servers. Single
license server networks are usually sufficient for most sites.
Note
If you are running redundant servers, you should have the license file (as well as the entire
licensing directory) installed locally on each license server. If you do not, you lose all the
advantages of having redundant servers, since the file server holding these files becomes a
single point of failure.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 2: Installing the ANSYS License Manager
The ANSYS, Inc. License Manager installation includes both a server and a client component. You must
install the license manager software on your server machine(s) at this release in order to be able to run
ANSYS, Inc. products. The updates at this release include the ANSYS Licensing Interconnect, the latest
daemons/services, and the latest ANSYS License Management Center and ANSLIC_ADMIN updates.
If you do not install the license manager at this release, your ANSYS, Inc. products will not run. You will
find detailed instructions for installing the license manager on your server machines later in this chapter.
References in this chapter to licensing installation refer to installing all necessary licensing components
on a machine designated as a license server machine.
Once the updated License Manager is installed on your server machine(s) and you have installed the
product(s), the client component will run successfully. The client component is installed automatically
during a product installation; users running as a client will not need to perform any additional installation
steps to successfully run the product(s). Note that the client component will not be installed with
Electronics (Ansoft) products, nor is it needed.
Linux Server Installation Notes: If you are installing the License Manager on the same machine
where the product will be run, use the same top level directory path for both the product installation
and the License Manager installation. We strongly recommend that you install the licensing files relative
to the product installation directory to avoid manually editing the product run scripts.
A typical product installation on a Linux machine allows you to install the product anywhere on the
system and then creates a symbolic link from the installation directory to /ansys_inc. If you did not
set the symbolic link during the product installation, or if you installed the licensing files somewhere
other than relative to the installation directory, replace all references to /ansys_inc in this guide
with the name of the installation directory you used. Any reference throughout this manual to the li-
censing directory on Linux platforms means /ansys_inc/shared_files/licensing.
Windows License Server Installation Notes: The licensing installation on a Windows machine installs
all necessary licensing files into the \Program Files\ANSYS Inc\Shared Files directory by
default, located on the same drive as the operating system, regardless of where your product installation
resides. You must have administrative privileges on your machine to install the licensing files. The license
manager components are shared across all ANSYS, Inc. products and need to reside in the same location
for all ANSYS, Inc. products and releases.
Any reference throughout this manual to the licensing directory on Windows platforms means \Program
Files\ANSYS Inc\Shared Files\Licensing, located on the same drive as the operating system,
or the directory where you installed the licensing files. If you choose to install the ANSYS, Inc. License
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
Installing the ANSYS License Manager
Manager to a different location, you must replace any references to \Program Files\ANSYS
Inc\Shared Files\Licensing with the directory where you installed the license manager.
Windows/Linux License Client Installation Notes: The license client files are automatically installed
into the \Shared Files\Licensing (Windows) or the /shared_files/licensing (Linux)
subdirectory of the product installation at the end of the product installation. Note that the client
component will not be installed with Electronics (Ansoft) products, nor is it needed.
TCP/IP is supplied as part of the Linux operating system. Table 2.1: Configuring TCP/IP (p. 12) specifies
the system utility used to configure TCP/IP on the various hardware platforms. You should consult your
network administrator for assistance with this configuration.
Note
For Windows systems, the TCP/IP protocol is included as part of the operating system and is typically
installed by default. If you do need to install TCP/IP, remember that it must be bound to a network
adapter.
On machines that are connected to an internal network, TCP/IP must be bound to a network card such
as an Ethernet adapter. The vast majority of systems using TCP/IP will fall into this category.
On machines that connect to the Internet or corporate intranet through a modem, TCP/IP can be bound
to a dial-up connection.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing the License Manager
If TCP/IP is installed, you must determine whether it is bound to a network adapter card or a dial-up
connection. A network card or a Dial-Up Adapter will be shown under Connect Using:.
Caution
If your computer is connected to a network, it is highly recommended that you contact your
Information Technology Department before installing or modifying TCP/IP on your machine.
2.1.2. Changing the Default ANSYS Licensing Interconnect and FlexNet Port
Numbers
A port number specifies the communications channel by which two or more processes can communicate.
ANSYS uses 2325 as the default port number for the ANSYS Licensing Interconnect and 1055 as the
default port number for the FlexNet component of the license manager. ansyslmd also uses a port
designated by the operating system, unless one is manually specified in the license file on the VENDOR
line. If you encounter a conflict in port numbers, you can change the default by modifying all of the
following files:
ANSYS Licensing Interconnect Port Number The ANSYS Licensing Interconnect port number is
defined in the ansyslmd.ini file. You can change this file by selecting Specify the License Server
Machine on the ANSLIC_ADMIN utility. Enter the new port number in the ANSYS Licensing Intercon-
nect Port Number field. The Licensing Interconnect port number may also be specified via the AN-
SYSLI_SERVERS environment variable, if set.
FlexNet Port Number To change the default FlexNet port number, you need to change the following
files:
On the license server machine(s): the port number listed on the SERVER line in the license file (an-
syslmd.lic).
On the client machine(s): the port number listed in the ansyslmd.ini file. Use the Specify the License
Server Machine option of the ANSLIC_ADMIN utility to change the ansyslmd.ini file. The FlexNet port
number may also be specified via the ANSYSLMD_LICENSE_FILE environment variable, if set.
ansyslmd Port Number The ansyslmd daemon uses a port designated by the operating system,
unless one is manually specified in the license file on the VENDOR line. See VENDOR Lines (p. 4) for
information on specifying this port number on the VENDOR line. You should need to specify this port
number manually only if using a firewall.
For information on firewall settings, see Specifying Firewall Settings (p. 27).
To proceed with the installation, the current license manager must be shut down if it's running. The
installation process will shut down the license manager; however, you should verify that no users will
be affected while you run the installation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
Installing the ANSYS License Manager
When you run the license manager installation on the license servers, the licensing installation process
will install all necessary files, as well as set the ANSYSLIC_DIR environment variable in the product-run
scripts. If there is an existing license manager, the installation process will shut it down, so you should
verify that no users will be affected while you run the installation.
Note that the FLEXlm for Ansoft (ansoftd) license manager will also be shut down and uninstalled if its
running; all associated license files will be migrated over to the ANSYS License Manager. Once migrated,
you will no longer be able to run the ANSYS License Manager and the FLEXlm for Ansoft License Manager
on the same system.
To support the ANSYS License Management Center, a Tomcat web server and Java will be installed
within the license manager directory during the ANSYS License Manager installation . To view the latest
Tomcat and Java versions installed, access the View Licensing Configuration Details option described
in Accessing the Help Options (p. 40).
New licenses for existing customers may not be supplied with the ANSYS Release 16.0 package. They
will be supplied when the current licenses expire or when TECS expires.
Run the license manager installation on all machines that will act as license servers.
On Windows systems you must have administrator privileges to perform the installation.
Note
On Windows systems, you cannot perform a platform license server installation (that is,
install files for a different machine type than you are running on).
1. Right-click the setup.exe file and select Run as administrator. If you downloaded the license manager
installation package, this file will reside in the directory where you unzipped the files. If you are running
from media, this file will reside in the top level of the media.
If you downloaded only the license manager installation, run setupLM.exe by right-clicking the
file and selecting Run as administrator.
4. You will be notified that the license manager (ANSYS or FLEXlm for Ansoft (ansoftd)), if running, will be
shut down. Click OK.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing the License Manager
5. The License Agreement screen appears. Read the license agreement, and if you agree, click I Agree to
accept the terms and click Next. You must select I Agree to continue with the installation.
6. Specify the installation directory. You can accept the default or specify an alternate path and the directory
name where the license manager is to be installed. The installation directory is set to
<OS_Drive>\Program Files\ANSYS Inc by default. You must have administrative privileges for
the directory you specify. In addition, the directory:
Note
You are not permitted to change the installation directory for a computer that currently
contains an instance of the ANSYS, Inc. License Manager. To change the installation
directory location, you must first uninstall any previous versions of the product.
7. The ANSYS, Inc. License Manager is the only component available and is selected to be installed. The
amount of disk space required and the disk space available appear at the bottom of the window. If the
disk space required exceeds the disk space available, be sure that you have sufficient space before con-
tinuing. The disk space required as calculated by the installation program may be greater than the actual
amount needed. However, if you choose to continue the installation, you should carefully review any log
and error files at the end of the installation to ensure that the installation completed successfully.
8. A summary of the selected installation data appears. Information shown includes platform, installation
directory, and product. Review the information carefully, and if correct, click Next to continue the install-
ation.
9. Once the product installation has occurred, the installation program performs a silent licensing config-
uration. Click Next to continue the installation.
The Launch License Management Center upon exiting option is included on the screen. The
ANSYS License Management Center is a browser-based application that centralizes many of the
ANSYS licensing administrative functions. For more information, see License Server Administration
Using ANSYS License Management Center (p. 31).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
Installing the ANSYS License Manager
If you do not want to launch the License Management Center, uncheck the Launch License Man-
agement Center upon exiting option.
Note
If the installation did not complete or completed with errors, review the progress
log by clicking the View Detailed Progress Log button.
10. When the license manager installation is complete, click Exit. A new Start Menu item named ANSYS, Inc.
License Manager will be created automatically. It will include selections for the License Management
Center, the ANSYS, Inc. Licensing Guide, the FlexNet License Administration Guide and the ANSLIC_ADMIN
utility.
Note
Client machines will also include a Client ANSLIC_ADMIN option under the ANSYS 16.2
Start Menu folder. The client-only version of ANSLIC_ADMIN offers access to a limited
number of ANSLIC_ADMIN features, such as user configuration and status/reporting
options. Note that the client component will not be installed with Electronics (Ansoft)
products, nor is it needed.
On Windows, if you encounter a problem during the licensing installation process that results in a failure
or abort, or if you are concerned that the licensing installation did not complete correctly, we recommend
that you re-run the License Manager installation.
1. Run INSTALL.LM to launch the license manager installation. If you downloaded the license manager
installation package, this file will reside in the directory where you untarred the files. If you are running
from media, this file will reside in the top level of the media.
2. Select a language.
3. You will be notified that the license manager (ansyslmd and/or ansoftd), if running, will be shut down.
Click OK.
4. The License Agreement screen appears. Read the license agreement, and if you agree, click I Agree to
accept the terms and click Next. You must select I Agree to continue with the installation.
5. If you are installing more than one platform or if you are installing a platform other than your current
machine type, you will need to select the platform(s) on which you want to install the ANSYS, Inc. License
Manager. The platform on which you launched the installation will be selected by default and is shown
at the bottom of the window. Click Next to continue.
6. The mount directory (location where the installation is located) is specified. You should accept the default.
You can also accept the default installation directory or specify an alternate path and directory name
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing the License Manager
where the license manager is to be installed. You cannot use wide character names/paths in the installation
directory.
Note
You are not permitted to change the installation directory for a computer that currently
contains an instance of the ANSYS, Inc. License Manager. To change the installation
directory location, you must first uninstall any previous versions.
We recommend that you also set the symbolic link /ansys_inc to the directory where the ANSYS,
Inc. product is installed. The /ansys_inc symbolic link is set by default. The symbolic link option
is available only if you are installing as root. If you chose to set the symbolic link during the product
installation, you should set it here as well.
7. Select the components you want to install. You can choose to install the ANSYS, Inc. License Manager.
The amount of disk space required and the disk space available appear at the bottom of the window. If
the disk space required exceeds the disk space available, be sure that you have sufficient space before
continuing. The disk space required as calculated by the installation program may be greater than the
actual amount needed. However, if you choose to continue the installation, you should carefully review
any log and error files at the end of the installation to ensure that the installation completed successfully.
8. A summary of the selected installation data appears. Information shown includes platform, installation
directory, and product. Review the information carefully, and if correct, click Next to continue the install-
ation.
9. Once the product installation has occurred, the installation program performs a silent licensing config-
uration. Click Next to continue the installation.
The Launch License Management Center upon exiting option is included on the screen. The
ANSYS License Management Center is a browser-based application that centralizes many of the
ANSYS licensing administrative functions. For more information, see License Server Administration
Using ANSYS License Management Center (p. 31).
If you do not want to launch the License Management Center, uncheck the Launch License Man-
agement Center upon exiting option.
Note
If the installation did not complete or completed with errors, review the progress
log by clicking the View Detailed Progress Log button.
On Linux, if you encounter a problem during the licensing installation process that results in a failure
or abort, or if you are concerned that the licensing installation did not complete correctly, we recommend
that you re-run the License Manager installation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
Installing the ANSYS License Manager
To run a silent product installation, including the client licensing, see Silent Product and License Manager
Installation in the ANSYS, Inc. Installation Guide for your platform.
To silently install the ANSYS License Manager on Windows systems that will act as license servers, you
must run the setupLM.exe with the -silent option:
setupLM.exe -silent
To install the ANSYS License Manager on Linux systems that will act as license servers, you must run
the INSTALL.LM with the -silent option:
INSTALL.LM -silent -install_dir path
The silent license manager installation is valid only for the default Licensing Configuration option Run
the ANSYS Licensing Interconnect with FlexNet.
If you are installing the license manager to a non-default installation directory, you can use the silent
installation method, but only for the initial installation. To change the license manager installation dir-
ectory for future installations, you will need to either use the GUI installation or uninstall the license
manager before reinstalling to a different directory.
Note
You are unable to change the installation directory for a computer that currently contains
an instance of the ANSYS, Inc. License Manager. To change the installation directory location,
you must first uninstall any previous versions of both products.
You can use the following arguments when running a silent license manager installation:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing the License Manager
During a silent installation, any licensing configuration messages will be written to the licensing install-
ation configuration log file, install_licconfig.log, located in the installation directory.
Caution
A silent license manager installation could shut down the ANSYS, Inc. License Manager, af-
fecting other users who are using that license server machine.
If you are running a silent client installation, you can specify license server information as well.
-licserver- Specifies information to be used by the client for the license server. Valid only
info in conjunction with a silent product installation (setup.exe or INSTALL). See
the ANSYS, Inc. Installation Guide for your platform for details on running a silent
product installation, including client licensing.
Run the ANSYS Licensing Interconnect without FlexNet -- Use this option if you want to run a local
copy of the ANSYS Licensing Interconnect for better performance, such as if your server machine is in
a remote location, or to manage the server load better if your license server machine serves many users.
With this option, FlexNet licenses will be taken from another server machine. Use this option to run the
Licensing Interconnect on additional systems other than your license server; your site must still have
the Licensing Interconnect running on the license server machine.
Run the ANSYS Licensing Interconnect and FlexNet independently -- Use this option if you want
to manage your FlexNet licenses independently of the ANSYS, Inc. tools (for example, using Flexera
Software's FLEXnet Manager to manage multiple companies' FlexNet product licenses). This option
should be used only by experienced users with well-established licensing procedures.
These options are available through the Specifying the License Manager Run Mode option in the
ANSYS License Management Center after a license manager installation has been run on this machine.
For more information, see Specifying the License Manager Run Mode (p. 39)
If you have already configured your licensing and are changing to a different configuration option, you
must stop and restart the ANSYS, Inc. License Manager for these changes to take effect. Rereading the
license manager settings will not be sufficient.
Important
When using this advanced option, the license server holding the FlexNet licenses must also
have the Licensing Interconnect installed and running.
To use the ANSYS License Management Center to set up a license server that will run the Licensing
Interconnect without FlexNet, see Specifying the License Manager Run Mode (p. 39).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
Installing the ANSYS License Manager
Important
If you make changes to the license file, in addition to rereading the license file in FlexNet
(using your license management tools), you must also recache the license file in the Licensing
Interconnect by restarting the Licensing Interconnect or by using the Reread the License
Manager Settings option in the ANSYS License Management Center.
To use the ANSYS License Management Center to set up a license server that will run the Licensing
Interconnect and FlexNet independently, see Specifying the License Manager Run Mode (p. 39).
We recommend that you set your license manager to boot at system startup. Other optional post-in-
stallation tasks are included here. You will only need to configure your license server machine and
configure your client machines if those steps were not completed during the product or license server
installation processes.
Table 2.2: License Manager Automatic Startup Instructions (p. 21) details the steps that must be performed
on each license server to start the license manager automatically when the Linux system is rebooted.
Substitute your platform name (see Supported Hardware Platforms (p. ix)) wherever you see <platform>.
The instructions below include steps to remove any existing boot_ansflex; if you have already re-
moved the boot_ansflex, you can safely skip that step.
Note
The procedure described in this section starts the license manager at boot time as root. It is
not essential that the license manager be started by the root user; it may be run by a non-
privileged user, depending on your preference. If you do not want the license manager to
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Instructions
be started by root, modify LMUSER in the init_ansysli boot script to include the user
name you want to use at boot time.
Platform Instructions
Linux: Red Remove existing license manager startup information. Edit the file
Hat /etc/rc.d/rc.local and delete the ANSYS boot_ansflex lines.
Linux: SuSE Remove existing license manager startup information. Edit the file
/etc/rc.d/boot.local and delete the ANSYS boot_ansflex
lines.
Once the procedure is in place for starting the license manager automatically at boot time, reboot the
system to verify that the automatic boot procedure is working correctly.
When the system comes back up, check to see that the license manager is running by typing the appro-
priate ps command and looking for ansyslmd and ansysli_server in the resulting display under
the column labeled COMMAND. For example:
ps -ef|grep ansysli; ps -ef|grep ansyslmd
Next, check the license.log and the ansysli_server.log files in the licensing directory for
error messages. These files contains a history of ANSYS product activity across the network when this
computer is chosen as the master license server by the licensing software. They also contain start-up
messages and possibly error messages.
Platform Instructions
Linux Issue the following commands:
/etc/init.d/init_ansysli stop
chkconfig --del init_ansysli
rm /etc/init.d/init_ansysli
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
Installing the ANSYS License Manager
2.3.2. Starting the ANSYS Licensing Tomcat Server at System Boot Time
You can set Tomcat to start automatically at system boot time on Linux machines. This task is optional
but is recommended and should be done regardless of which type of license server configuration you
use. The License Management Center runs using the Tomcat web server. You can set Tomcat to start
automatically at system boot on Linux machines. This task is required to be able to run the License
Management Center.
Table 2.4: Tomcat Automatic Startup Instructions (p. 22) details the steps for each Linux hardware
platform that must be performed on each license server to start Tomcat automatically when the system
is rebooted.
Note
The procedure described in this section starts Tomcat at boot time as root. It is not essential
that Tomcat be started by the root user; it may be run by a non-privileged user, depending
on your preference. If you do not want Tomcat to be started by root, modify the LMUSER
value in the init_ansyslm_tomcat boot script to include the user login name you want
to use at boot time. This user must have read/write access to all files contained in the following
directories:
<Install Directory>/shared_files/licensing/tools/tomcat/conf
<Install Directory>/shared_files/licensing/tools/tomcat/logs
<Install Directory>/shared_files/licensing/tools/tomcat/bin
Platform Instructions
Linux: Red Issue the Tomcat startup instructions:
Hat and cp /ansys_inc/shared_files/licensing/init_ansyslm_tomcat /etc/init.d
SuSE chmod 555 /etc/init.d/init_ansyslm_tomcat
chkconfig --add init_ansyslm_tomcat
chkconfig init_ansyslm_tomcat on
Once the procedure is in place for starting Tomcat automatically at boot time, reboot the system to
verify that the automatic boot procedure is working correctly.
When the system comes back up, check to see that Tomcat is running by typing the appropriate ps
command and looking for init_ansyslm_tomcat in the resulting display under the column labeled
COMMAND. For example:
ps -ef|grep tomcat
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Instructions
Platform Instructions
Linux: Red Issue the following commands:
Hat and /etc/init.d/init_ansyslm_tomcat stop
SuSE chkconfig --del init_ansyslm_tomcat
rm /etc/init.d/init_ansyslm_tomcat
Note
The following procedure can only be used with a default Tomcat installation. This pro-
cedure cannot be used when Tomcat is installed as part of the secure connection option.
For more information, see, Enabling Secure Connections to the Web Server (Option-
al) (p. 41).
By default, the ANSYS License Manager installation sets the Tomcat port number to 1084. To manually
change this value, you must modify the server.xml file located in the following directory:
Windows:
<install_dir>\Shared Files\Licensing\tools\tomcat\conf
Linux:
/ansys_inc/shared_files/licensing/tools/tomcat/conf
4. If Tomcat is already running, the new port value will not be used until Tomcat is restarted. This can
be done in the following manner:
Windows:
Open the Windows Services applet and stop and restart the ANSYS Licensing Tomcat service
(ANSYSLicensingTomcat). The Windows Services applet can be started by issuing the command
services.msc from an administrator command prompt window.
Linux:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
Installing the ANSYS License Manager
b. Start the Tomcat server process with the new port number by executing the start_lmcenter
script.
Note
Starting the Tomcat server process will also open ANSYS License Man-
agement Center.
1. Open the ANSYS License Management Center. For Windows, click Start>All Programs>ANSYS, Inc. Li-
cense Manager>ANSYS License Management Center and for Linux run the /shared_files/licensing/start_lm-
center script.
2. Click the Get System Hostid Information option to display your system ID code(s).
3. Select the system ID you wish to use and click SAVE TO FILE.
4. Forward this text file to your ANSYS sales representative so that a license file can be created for you.
Add your license files though the ANSYS License Management Center. For these steps, see Adding
a License with the ANSYS License Management Center (p. 32).
If you are running in a three-server environment, the license file must reside on all three servers
and must match on all three servers. Therefore, install the same license file on each machine.
For a detailed description of the settings that you can change with this option, see Modify Startup
Options (p. 66).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Instructions
To specify a list of users with access to licensing administrative options, you need to create an lmadmin
group on computers from which license administration will be performed. If you create an lmadmin
group, you must include root in order for root to continue to have access to these functions. For more
details on using an lmadmin group, see the FlexNet License Administration Guide (accessible from the
ANSYS License Management Center). This option is available for Linux platforms only.
Follow the instructions below for your hardware platform to create an lmadmin group.
where nn represents any unique group number and user1, user2, user3, ..., usern represent a list
of n users in the group.
If you specify a group restriction, any users in that group who want to perform that operation must
have the specified group as their primary group. For example, adding the following restriction:
RESTRICT_SHUTDOWN=GROUP:lmadmin
restricts the ability to shut down the license manager to only members of the lmadmin group. Any user
who is a member of the lmadmin group and wants to shut down the license manager must have
lmadmin as his primary group:
machineabc{user1}: groups
other testing dev1 lmadmin
In the above example, user1 is a member of the groups other, testing, dev1, and lmadmin, where other
is the primary group and testing, dev1, and lmadmin are secondary groups.
To change a group from a secondary to a primary group, issue the newgrp (or equivalent) command:
machineabc{user1}: newgrp lmadmin
In this example, user1 now has lmadmin as his primary group and will be able to shut down the license
manager:
machineabc{user1}: groups
lmadmin other testing dev1
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
Installing the ANSYS License Manager
Allow or deny the use of features based on user, hostname, display name, group, etc.
By using the options file, you can be as secure or as open with licenses as you like.
The default location of the options file, ansyslmd.opt, is in the license_files directory. If you have a
three-server system, the options file must match exactly on all three servers.
If you are using an options file, you must specify the pathname to the file on the VENDOR line in the
license file, unless it uses the default name, ansyslmd.opt, and resides in the same directory as the
license file. On Linux systems, the VENDOR line would look like this for an options file named my.opt:
VENDOR ansyslmd options=/ansys_inc/shared_files/licensing/license_files/my.opt
On Windows systems, if the path has spaces in it, you must enclose it in quotes:
VENDOR ansyslmd options="c:\Program Files\ANSYS Inc\Shared Files\Licensing\license_files\my.opt"
The Specify the License Server Machine option of the ANSLIC_ADMIN utility creates a file named
ansyslmd.ini in the licensing directory. The ansyslmd.ini file contains your license server spe-
cification. For more information on specifying the license server, see Specify the License Server Ma-
chine (p. 59) in License Administration Using ANSLIC_ADMIN (p. 57).
On Windows server machines, use the Server ANSLIC_ADMIN utility (accessed via Start> All Programs>
ANSYS, Inc. License Manager> Server ANSLIC_ADMIN Utility) to modify the ansyslmd.ini file.
On client machines, use the Client ANSLIC_ADMIN utility (accessed via Start > All Programs > ANSYS
16.2>ANSYS Client Licensing > Client ANSLIC_ADMIN Utility 16.2). If you have both the server and
the client ANSLIC_ADMIN utilities on the same system, use the Client ANSLIC_ADMIN to specify ma-
chine-specific (local) settings.
If you want to set your license paths to have a particular license server machine for your use only (not
used by others who are running ANSYS products on this machine), you can do so by setting the AN-
SYSLI_SERVERS and/or ANSYSLMD_LICENSE_FILE environment variables. Use the ANSYSLI_SERVERS
environment variable to specify the Licensing Interconnect port number. Use the ANSYSLMD_LI-
CENSE_FILE to specify the FlexNet port number.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Instructions
are set, ANSYSLMD_LICENSE_FILE explicitly defines the FlexNet servers while ANSYSLI_SERVERS ex-
plicitly defines the Licensing Interconnect servers.
1. Install the License Manager on each of the three servers as described in Installing the License Man-
ager (p. 13). Be sure that each machine meets all of the prerequisites.
2. Start each of the license servers using the same license file on each machine. The license file for the three-
server setup will begin with three SERVER lines:
The first SERVER line is the license server you have designated as the primary server followed by
the second and third servers, which act as the backup servers.
3. Always start the primary server first. If not, the second or third server will take over as the master server.
When you start each license server, you will see a message indicating that the server is starting.
The primary server will not be fully started until you start the second or third server, creating a
quorum. Until you have a quorum of servers started, the ANSYS License Management Center
will show the Licensing Interconnect and monitor running while FlexNet will show as not running.
You could see a delay of up to five minutes in the startup of a server's FlexNet component while
the communication between all three servers is being established. If a connection cannot be estab-
lished within the five minutes, the Licensing Interconnect and Licensing Interconnect Monitor will
stop. Check the ANSYS License Management Center to verify that all components have stopped
before you attempt to restart the ANSYS, Inc. License Manager on any server.
To stop redundant servers, use the Stop the ANSYS, Inc. License Manager option of the ANSYS License
Management Center. In a redundant server configuration, the Licensing Interconnect will stop all three
servers when you choose to stop any one of the three servers. As with starting the license servers, if
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
Installing the ANSYS License Manager
one person is stopping each of the three servers, you could see a similar delay of five or more minutes
before all three are fully shut down.
Caution
If you have a three-license server network, we do not recommend that you load ANSYS,
Inc. products on a single file server; doing so eliminates the inherent safety of a redundant
setup.
The procedures described in this section assume that you have installed the ANSYS, Inc. License Manager
in the default locations. The default locations are:
Windows:
Linux:
/ansys_inc/
If you have installed the ANSYS, Inc. License Manager to a non-default location, please modify the steps
accordingly.
1. Stop the ANSYS, Inc. License Manager from the ANSYS License Management Center by following the
steps contained in Stopping the ANSYS, Inc. License Manager (p. 34).
2. Stop any ANSYS Tomcat server processes running from this installation directory by running the
stop_lmcenter script located in:
/ansys_inc/shared_files/licensing/
Note
Do not delete this directory if ANSYS products are also installed in the installation directory.
4. Remove the ANSYS, Inc. License Manager automatic startup information by issuing the commands in
Table 2.3: Removing License Manager Automatic Startup Instructions (p. 21).
5. Remove the Tomcat automatic startup information by issuing the commands in Table 2.5: Removing
Tomcat Automatic Startup Instructions (p. 23).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.
Uninstalling the License Manager
1. Stop the ANSYS, Inc. License Manager from the ANSYS License Management Center by following the
steps contained in Stopping the ANSYS, Inc. License Manager (p. 34).
2. Uninstall the ANSYS, Inc. License Manager service. You must use the following command to do so:
"C:\Program Files\ANSYS Inc\Shared Files\Licensing\winx64\ansysli_server"
-k uninstall
3. Uninstall the ANSYS Licensing Tomcat service. You must use the following commands to do so:
sc stop "ANSYSLicensingTomcat"
sc delete "ANSYSLicensingTomcat"
4. Delete the Shared Files subdirectory (C:\Program Files\ANSYS Inc\Shared Files by default).
Note
Do not delete this directory if ANSYS products are also installed in the installation dir-
ectory.
5. Remove the ANSYS, Inc. License Manager folder from the Start menu.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 29
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
30 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 3: License Server Administration Using ANSYS License
Management Center
This chapter explains how to use the ANSYS License Management Center (LM Center) to perform
many of the procedures necessary to administer ANSYS licenses. The ANSYS License Management
Center is a browser-based user interface that centralizes many of the ANSYS licensing administrative
functions. Basic license administration functionality has been incorporated into the ANSYS License
Management Center; some advanced options remain in the ANSLIC_ADMIN utility. See Using the AN-
SLIC_ADMIN Utility (p. 57) for more information on the ANSLIC_ADMIN utility.
Note
For Windows systems, ANSYS, Inc. requires that you have system administrator privileges to
start the ANSYS License Management Center. To use the ANSYS License Management
Center, you must access it from the local license server machine.
Firefox 28 or greater
Chrome 36 or greater
Note
ANSYS License Management Center uses your default browser when opening. If
you have not defined a default browser, ANSYS License Management Center attempts
to open using Windows Internet Explorer from the default installation location. If
Windows Internet Explorer is not installed in the default location, an error is reported.
Firefox 17 or greater
Windows 7:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 31
License Server Administration Using ANSYS License Management Center
Windows 8:
1. From the Start screen, click the arrow located in the lower left portion of the screen to access the Windows
Apps.
Linux
The following sections provide instructions on how to perform the licensing administration functions
available through the ANSYS License Management Center:
3.3.1. Adding a License with the ANSYS License Management Center
3.3.2. Starting the ANSYS, Inc. License Manager
3.3.3. Stopping the ANSYS, Inc. License Manager
3.3.4. Rereading the License Manager Settings
3.3.5. Displaying the License Server Machine Hostid Information
3.3.6. Viewing FlexNet Licenses
3.3.7. Viewing the Licensing Interconnect Log
3.3.8. Viewing the FlexNet Debug Log
3.3.9. Viewing the ANSYS License Management Center Log
3.3.10. Gathering Diagnostic Information
3.3.11. Specifying the License Manager Run Mode
3.3.12. Accessing the Help Options
Important
When adding a license file, the Add A License option in the ANSYS License Manage-
ment Center validates the new license file for the system, attempts to correct issues
that it recognizes, and ensures port number consistency. For this reason, you must use
the ANSYS License Management Center to add license files, rather that manually placing
them in the license_files directory.
This option validates a user-specified license file and, if the license file is found to be valid, installs it
into the license_files directory. After installing the license file, this option communicates the new license
file's information to the ANSYS, Inc. License Manager either by starting /restarting the license manager
or by rereading the license manager's settings.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
32 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSYS License Management Center
The ANSYS, Inc. License Manager supports both ANSYS and Ansoft FlexNet license files. ANSYS license
files contain the FlexNet vendor daemon ansyslmd and, after being installed, have the naming convention
ansyslmd.lic. Ansoft license files contain the FlexNet vendor daemon ansoftd and, after being installed,
have the naming convention ansoftd.lic. Both ANSYS and Ansoft license files contain the licensing in-
formation which allows you to run ANSYS, Inc. products.
If a vendor license file is already installed for the vendor contained in the license file you are installing,
the previously-installed license file will be renamed to have the form license_<vendor>_<timestamp>.lic
and moved to the backup subdirectory in the license_files directory.
1. Save the license file that you received from your ANSYS sales representative to a temporary file.
Caution
7. If the selected license file is not valid, the process ends with the Status pane displaying an error message
containing details.
8. If the license file is valid, the Add A License File dialog box is displayed:
If the ANSYS, Inc. License Manager is not running, you are informed that it will be started when
the license file is added.
If the ANSYS, Inc. License Manager is running, you are given the option of either restarting it or
rereading the license manager settings. For more information, see Rereading the License Manager
Settings (p. 35)
The Status pane displays a message informing you of the steps taken successfully along with any
errors that were encountered.
You must perform this process, using the same license file, on each license server machine.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 33
License Server Administration Using ANSYS License Management Center
To use the ANSYS License Management Center to start the license manager, ANSYS License Manage-
ment Center (including the ANSYS Licensing Tomcat Server and the license manager must be installed
on the same computer. Additionally, a valid license file must be installed prior to starting the license
manager. To facilitate the start process, verify that ANSYS License Management Center and license
manager are both installed on the same machine and that a valid license file exists in the license_files
directory.
2. Click the Start button located on the right side of the page.
The Status pane displays a message informing you whether the ANSYS, Inc. License Manager started
successfully or if any errors have been encountered. Additionally, a green check mark status icon
is displayed indicating that the license manager is running.
Note
Every seven seconds, the ANSYS License Management Center verifies that the li-
cense manager is running and updates the status icon.
The ansyslmd.lic file is provided by an ANSYS sales representative and contains licensing for all the
ANSYS, Inc. products that you are entitled to use.
The ANSYS, Inc. License Manager must be running on at least two of the three servers before an ANSYS
product can be run.
In a three-server environment, you may see a delay in starting the ANSYS, Inc. License Manager until
two of the three servers are running.
Before shutting down the ANSYS, Inc. License Manager, check that no products that use it are currently
running.
2. Click the Stop button located on the right side of the page.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
34 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSYS License Management Center
You are asked to confirm that the license manager should be shut down. Remember that the license
manager must be running in order to run products that use it for their licensing.
The Status pane displays a message informing you whether the license manager stopped successfully
or if any errors have been encountered. Additionally, a red stop sign icon is displayed indicating
that the license manager is no longer running.
Caution
(Linux systems) Do not use kill -9 to shut down the ANSYS, Inc. License Manager. Use the
ANSYS License Management Center, the anslysli_stop script or ansysli_server
-k stop [port@host] to perform the shutdown.
In a three-server environment, you may see a delay in stopping the license manager until two of the
three servers are stopped.
This option:
Rereads the ansyslmd.ini file to get any new settings, such as log file size or change of name
Be aware that if you change the Licensing Interconnect port number, you will need to restart the license
manager; a reread will not update the port number.
Note
If you chose to configure your license manager to run the Licensing Interconnect without
FlexNet or run the Licensing Interconnect and FlexNet independently, then selecting this
option will affect only the Licensing Interconnect components including recaching the license
file when running the Licensing Interconnect and FlexNet independently.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 35
License Server Administration Using ANSYS License Management Center
The Status pane displays a message informing you whether the ANSYS, Inc. License Manager's settings
were successfully reread.
If you wish to use a FLEXID9 dongle as the hostid, make sure the device is inserted and the correct
device driver is installed. For more information, see Using Dongles with the ANSYS License Man-
ager (p. 71). Dongles are only available for those sites that require the ability to run ANSYS products
on an isolated network.
The Hostid information is displayed on the right-hand side of the page. The HOSTNAME,
Hostid, IDTYPE and PLATFORM information is included. Windows systems use the physical
machine disk serial number and Linux systems use the MAC address by default.
3. To save this information out to a file, click the SAVE TO FILE button. By default, the file is named an-
sysid.machinename.txt.
A field containing the name of one of your FlexNet license files is displayed.
3. Select the FlexNet license file you want to view by clicking the arrow located on the right side of the field
and choosing the appropriate file from the drop-down menu. Note the drop-down menu is populated with
any FlexNet license files (.lic) contained in the following directory:
Windows:
\Program Files\ANSYS Inc\Shared Files\Licensing\license_files
Linux:
/ansys_inc/shared_files/licensing/license_files
4. The contents of the FlexNet license is displayed on the right side of the page.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
36 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSYS License Management Center
The Licensing Interconnect log file is displayed on the right side of the page.
3. To download a text version of the interconnect debug log file, click the SAVE TO FILE button.
4. To manually refresh the Licensing Interconnect log file, click the REFRESH button.
Note
The Licensing Interconnect log file (ansysli_server.log) can be found in the licensing directory. To
manually access this file, go to the following locations (by default):
Windows:
\Program Files\ANSYS Inc\Shared Files\Licensing\ansysli_server.log
Linux:
/ansys_inc/shared_files/licensing/ansysli_server.log
License manager error messages associated with the FlexNet component of the license manager.
The FlexNet debug log is displayed on the right side of the page.
3. To download a text version of the FlexNet debug log, click the SAVE TO FILE button.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 37
License Server Administration Using ANSYS License Management Center
4. To manually refresh the FlexNet debug log, click the REFRESH button.
Note
The FlexNet debug log (license.log) can be found within the licensing directory structure by default.
To manually access this file, go to the following location:
Windows:
\Program Files\ANSYS Inc\Shared Files\Licensing\license.log
Linux:
/ansys_inc/shared_files/licensing/license.log
The ANSYS License Management Center log is displayed on the right side of the page.
3. To download a text version of the ANSYS License Management Center log, click the SAVE TO FILE button.
4. To manually refresh the ANSYS License Management Center log, click the REFRESH button.
Note
The ANSYS License Management Center log (ansyslmcenter.log) can be found within the licensing
directory structure. To manually access this file, go to the following location:
Windows:
\Program Files\ANSYS Inc\Shared Files\Licensing\tools\lmcenter\logs\ansyslmcenter.log
Linux:
/ansys_inc/shared_files/licensing/tools/lmcenter/logs/ansyslmcenter.log
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
38 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSYS License Management Center
Note
On Windows, this process may take a few minutes when msinfo32.exe is running.
The ANSYS License Management Center begins to collect the files and information. After the col-
lection process is complete, all files that are found and included in the compressed file are listed.
4. Based upon how your default browser is configured, you will either be prompted for a location to save the
compressed file or the compressed file will be automatically saved to your pre-defined location.
Windows:
\Program Files\ANSYS Inc\Shared Files\Licensing\
Linux:
/ansys_inc/shared_files/licensing/
On Windows you must run this script from an administrator command line (do not double click the
batch file). Running this script from a command line produces a single compressed file (ansyslmd_dia-
gnositics<unique numeric identifier>). This file contains the same licensing related files, logs and inform-
ation produced by running the Gather Diagnostic Information option within the ANSYS License
Management Center.
Run the ANSYS Licensing Interconnect without FlexNet Use this option if you want to run a local
copy of the ANSYS Licensing Interconnect on another machine in addition to the Licensing Interconnect
being run on the license server machine. Your site must still have the Licensing Interconnect and FlexNet
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 39
License Server Administration Using ANSYS License Management Center
running on the license server machine. With this option, FlexNet licenses will be taken from another
server machine. Note that this is not the default way to set up an ANSYS license server machine and
should be done only if it has been determined that you need this special type of setup. Examples of
when this special type of setup might be used include increasing performance if your server machine
is in a remote location or managing the server load better if your license server machine serves many
users.
Run the ANSYS Licensing Interconnect and FlexNet independently Use this option if you want to
manage FlexNet Licensing independently of the ANSYS Licensing Interconnect. In this option, you would
continue to manage the ANSYS Licensing Interconnect via the ANSYS License Management Center and
FlexNet Licensing would be managed via another tool, such as Flexera Software's FlexNet Manager.
Note that this is not the default way to set up an ANSYS license server machine and should be done
only by experienced users with well-established licensing procedures.
These options are available for license server machines via the ANSYS License Management Centers
Specify License Manager Run Mode option only after an ANSYS, Inc. License Manager installation has
been run on this machine.
Caution
Changing the run mode will cause the ANSYS License Manager to be shut down and restarted.
The License Manager Run Mode Specification page, containing each of the run modes, is displayed.
Note
The default run mode is Run the ANSYS Licensing Interconnect with FlexNet.
Note
Clicking any option that is not relevant to your current run mode will cause ANSYS
License Management Center to display a page informing you that this option is
not supported by the current run mode.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
40 of ANSYS, Inc. and its subsidiaries and affiliates.
Enabling Secure Connections to the Web Server (Optional)
View ANSYS Licensing Guide: This option accesses the current PDF version of the product manual.
View FlexNet Licensing Guide: This option accesses the current PDF version of the FlexNet Publisher License
Administration Guide.
View Licensing Configuration Details: This option displays the version numbers and file locations for
ANSYS License Management Center related options (Java, Tomcat, FlexNet, etc.).
About License Management Center: The option includes the ANSYS License Management Center
product information (version number, copyright, etc.).
When communications between the client browser and the front-end web server need to travel over
an untrusted network such as the Internet, it is highly advisable to use secure connections between
the client browser and the front-end web server. SSL, or Secure Socket Layer, is a technology which allows
web browsers and web servers to communicate over a secured connection. Data is encrypted by each
communicator, transmitted and then decrypted by the other communicator. Additionally, the SSL protocol
authenticates credentials during your initial attempt to communicate over the secure connection.
SSL/TLS certificates are typically purchased from well-known Certificate Authorities (CA) such as VeriSign
and Thawte. Using a certificate from a well-established and widely recognized CA confers several benefits
to the web server operator. These include increased credibility and convenience because the root cer-
tificates for popular CAs are prepackaged into major browsers, eliminating the need to distribute anything
to client browsers that will connect to the web site.
If a web server is to be used solely internally within an organization, then the benefits of using a certi-
ficate from a well-recognized Certificate Authority may not be important. Any valid SSL/TLS certificate
can be used to encrypt traffic between client browser and web server as long as the client browser
accepts the certificate. For internal production use, and certainly for test use, it is often sufficient to
create and use an in-house Certificate Authority that can sign SSL/TLS certificates for these use cases.
A certificate that is signed by the same party that created it is known as a self-signed certificate. When
an internally-generated certificate is signed using an in-house Certificate Authority, then a self-signed
certificate is created. Self-signed certificates are perfectly usable for enabling HTTPS connections to a
web server. However, when a browser encounters a certificate that has been signed by an unknown
certificate authority, it will present the user with a warning, such as the following:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 41
License Server Administration Using ANSYS License Management Center
Once a user accepts the certificate, the HTTPS connection can proceed.
Using the keytool command line, create the keystore file as follow:
Go to the tools directory in your installation and execute the following platform specific commands:
Windows
Linux
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
42 of ANSYS, Inc. and its subsidiaries and affiliates.
Enabling Secure Connections to the Web Server (Optional)
cd /ansys_inc/shared_files/licensing/tools
Go to the licensing/tools/tomcat/conf directory in your installation and edit the server.xml file by adding:
<Connector protocol="org.apache.coyote.http11.Http11NioProtocol"
port="8443" maxThreads="150"
scheme="https" secure="true" SSLEnabled="true"
keystoreFile="conf/keystore"
keystorePass="changeit"
keyPass="changeit"
clientAuth="false" sslProtocol="TLS" />
where "changeit" is the password you specified when you created the keystore file above.
You can now use ANSYS License Management Center with HTTPS by restarting your ANSYS Licensing
Tomcat service and pointing to https://localhost:8443/ANSYSLMCenter.html.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 43
License Server Administration Using ANSYS License Management Center
Note
Changing the version of Java is only possible when the Java version is newer than the
version supplied as part of the ANSYS installation.
3.5.1. Changing the Java Version During a New Installation of ANSYS, Inc. Li-
cense Manager
Windows or Linux:
1. Prior to performing the ANSYS, Inc. License Manager installation, set the following environment variable
to point to the location of the Java version you want to use.
ANSYSLM_USER_JAVA_HOME
3.5.2. Changing the Java Version on an Existing Installation of ANSYS, Inc. Li-
cense Manager
Windows:
1. Set the following environment variable to point to the location of the Java version you want to use.
ANSYSLM_USER_JAVA_HOME
2. As an administrator, re-run the ANSYS, Inc. License Manager installation or run ansyslm_config.exe
-usemyjava .
Note
When running this command on Windows 8.1, the message "Qt: Untested Windows version
6.2 detected!" may be displayed. You can safely ignore this message.
Linux:
1. Set the following environment variable to point to the location of the Java version you want to use.
ANSYSLM_USER_JAVA_HOME
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
44 of ANSYS, Inc. and its subsidiaries and affiliates.
Changing the Version of Java Used by ANSYS License Management Center
3. Run the start_lmcenter script to configure Tomcat to use your version of Java and start Tomcat.
Both the start_lmcenter script and the stop_lmcenter script are located in:
/ansys_inc/shared_files/licensing/
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 45
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
46 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 4: End-User Settings
End users can set several controls for a customized licensing environment. These controls are explained
in this chapter.
ANSYSLMD_LICENSE_FILE
Can be used to identify a license server machine or license file. If set, this specification is used before
any other license path information. See License Files Settings Precedence (p. 48) for precedence in-
formation. The default port number assigned to ANSYS, Inc. is 1055. Therefore, if your server has the
hostname alpha1 and the IP address of 10.3.1.69, you can identify the server to use as 1055@alpha1
or 1055@10.3.1.69.
ANS_FLEXLM_DISABLE_DEFLICPATH
Indicates that the default license path should not be searched when determining the licensing path
in the ANSYS product. When this environment variable is set:
Settings in the ansyslmd.ini file and the license file in the licensing directory will NOT be used.
It will ignore the local server and will ignore the Specify the License Server setting.
ANSYSLI_SERVERS
Used to identify the server machine for the Licensing Interconnect. Set to port@host. The default
port is 2325. This setting takes precedence over settings specified in the ansyslmd.ini file.
ANSYSLI_TIMEOUT_CONNECT
Used to specify the amount of time that elapses before the client times out if it cannot connect to
the server. Default is 20 seconds. Minimum timeout period you can specify is 5 seconds and the
maximum is 60 seconds. If the client determines that a server is not available in less time, it will cancel
immediately.
ANSYSLI_TIMEOUT_TCP
Used to specify the amount of time that elapses before the client times out if it cannot get a response
from the server. This setting applies only when the license server is running but is responding slowly
(generally because of network issues or server load). Default is 60 seconds. Minimum timeout period
you can specify is 30 seconds and the maximum is 300 seconds.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 47
End-User Settings
3. Settings in the ansyslmd.ini file in the relative client licensing directory for ANSYSLI_SERV-
ERS=keyword
2. Settings in the ansyslmd.ini file in the relative client licensing directory for SERVER=keyword.
Note
The FlexNet environment variable LM_LICENSE_FILE is not supported with the ANSYS, Inc.
License Manager.
You can use this option to review the licenses available, prioritize the licenses, and establish which li-
censes you will use. When you select this option, a dialog box opens. All licenses available to you on
your license server machine(s) are shown under the appropriate tab:
Solver
PrepPost
Geometry
HPC
You control the order in which the system attempts to check-out a license by moving the licenses up
and down in the list using the Move Up or Move Down buttons. When you open an application, the
license manager attempts to check-out the license listed first in the list. If unable to check-out that license,
then the license manager attempts to check out the next license in the list that can be used by the
application. The license manager will continue through the list until an available license is found. If
none are found, a message displays.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
48 of ANSYS, Inc. and its subsidiaries and affiliates.
Establishing User Licensing Preferences
By default, all licenses available from your license server are shown and marked as available for use. If
you do not want a particular license to be available for your use, select the license in the list, and set
the Use/Don't Use field to 0.
If you received a new license, you may need to reset your preferences. If you had previously set your
license preferences using this option, add the new license to your list in the desired order.
If you have made changes to your license preferences, you can return the settings to the default state
by selecting the Reset to Default button.
When you have completed your changes, click OK to make the changes and close the dialog box. Click
Apply to make the changes without closing the dialog box. Selections you make here will take effect
with any new sessions/license checkouts but will not affect the current session or change the license(s)
currently in use.
If you are sending solve jobs to a remote compute cluster via Remote Solve Manager (RSM), note that
your license preferences set for your local machine (the RSM Client) may not be the same as the license
preferences set for the remote cluster machine (the Compute Server). In cases where local and remote
license preferences are different, the preferences for the local RSM Client machine will not be applied
when running on the remote Compute Server; instead, the preferences defined for the remote Compute
Server will be used. If the license preferences and/or the licensing checkout order do not make the
necessary licenses available to your remote solve, you must adjust the Compute Server preferences by
setting your license preferences on the remote machine. Remote license preferences may be defined
according to corporate IT policy, so see your license administrator about adjustments to Compute
Server preferences.
Use the Licensing Preferences dialog box (Start > All Programs > ANSYS 16.2 > ANSYS Client Licensing
> User License Preferences 16.2) to specify which method to use and which licenses to use. You must
specify the licensing method before starting an ANSYS Workbench session. If you access the Licensing
Preferences dialog box from the ANSYS Workbench Tools menu, you will not be able to choose a licensing
preference from there.
Single License Sharing ANSYS Workbench allows you to work across multiple applications and
workspaces in ANSYS Workbench while consuming only one of a single type of license per user per
session. Using shared licensing, the active application holds the license, preventing other applications
that are sharing that license from using it during that time. The application or operation requiring use
of the license is called a concurrency event. For example, meshing and solving would each be a concur-
rency event.
Single license sharing allows you to progress through your analysis, from specifying engineering data
through building or attaching a geometry, meshing, setup, solving, and finally, reviewing your results,
all under the same license. The application holding the license must close or issue a PAUSE command,
or receive an automatic release request to release the license and allow another application to use it.
Licenses cannot be released while an application is actively performing a licensed operation (for example,
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 49
End-User Settings
an application cannot release a license in the middle of a solve operation; the license cannot be released
until the solve operation is completed).
Single license sharing applies only to licenses of the same type (e.g., Mechanical). Choosing this option
does not affect your ability to use licenses of different types simultaneously (e.g., Mechanical for one
task and Fluid Dynamics for another).
Because this method is the default, you do not have to take any action to run this way.
Explanation of License Type and Examples License type is primarily by license feature. It is possible
to use both a Mechanical and an Emag license within a single ANSYS Workbench session. It is also
possible to use both a Multiphysics and a Mechanical license within a single ANSYS Workbench session.
The first license checked out within a session will be based on your preferences and what capabilities
are being requested. For all applications other than the first (subsequent) one opened (within ANSYS
Workbench), ANSYS licensing will first look at what other licenses are opened within this session. These
subsequent license requests will look at sharing first to satisfy their request: do any other licenses being
used within this session fulfill the needed capabilities? If yes, share an existing license. If not, preferences
are used and a new, different license is checked out.
Example 1: You have one license for Multiphysics and one license for Mechanical, with Multiphysics
listed first in your preferences. The first application starts and only needs capabilities in Mechanical.
Since Multiphysics contains Mechanical capabilities and is first in your preferences, Multiphysics will be
checked out. The second application starts and needs Multiphysics; since Multiphysics is already checked
out, the second application will share it with the first. Only the Multiphysics license is consumed in this
session.
Example 2: You have one license for Multiphysics and one license for Mechanical, with Mechanical listed
first in your preferences. The first application starts and only needs capabilities provided in Mechanical,
so Mechanical is checked out. The second application starts and needs capabilities provided on Mul-
tiphysics; since (the already in use) Mechanical cannot satisfy its requirements, it checks out Multiphysics.
Both a Multiphysics and a Mechanical license are consumed in this session.
Restrictions of Single License Sharing You cannot run two concurrency events simultaneously (for
example, you cannot mesh one model and solve another simultaneously) with one license.
If you are using a license for one application, other applications may still not be able to share that license
if those applications require capabilities not supported by the license. For example, you cannot share
a Mechanical license with a Fluent application.
Single License Sharing in ANSYS Workbench Applications ANSYS Workbench applications handle
single license sharing differently:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
50 of ANSYS, Inc. and its subsidiaries and affiliates.
Establishing User Licensing Preferences
only mode while Meshing uses the license, allowing you to view the data in other components but
not operate on it.
Note
Applications in read-only mode because of shared licensing do not refresh their li-
cense status automatically. Once the shared license is released by the editor that
had consumed it, you must trigger Mechanical to query the license status. The most
straightforward way to do this is click outside the Mechanical application window
and then click back in the window to cause the license availability to be rechecked.
Autodyn and Polyflow also provide a manual PAUSE feature that allows you to interrupt
Autodyn or Polyflow and release the license, temporarily, for another application to use.
Separate Licenses By using the separate-licenses method, ANSYS Workbench requires a separate
license for each application. By using this method, you can move freely between the many applications
that you might require during an analysis in ANSYS Workbench, provided that you have sufficient licenses.
You can leave each application running and easily move between them at any point during the analysis,
even if one of the applications is actively using the license (such as during a solve process). The disad-
vantage to this method is that you could potentially consume many licenses.
To activate the separate licenses method, choose Use a separate license for each application in the
Licensing Preferences dialog box (Start > All Programs > ANSYS 16.2 > ANSYS Client Licensing >
User License Preferences 16.2). You must specify the licensing method before starting an ANSYS
Workbench session.
Examples of Using Separate Licenses You have two Mechanical licenses. When you open and mesh
or solve a model in the Mechanical application, you consume one Mechanical license. If you link that
Mechanical analysis to a Mechanical APDL system, you would consume a second Mechanical license
when you launch the Mechanical APDL application, if you have not closed out of the Mechanical applic-
ation. Neither of these licenses would then be available for other users until you closed out of one or
both of the applications.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 51
End-User Settings
do not apply to ANSYS LS-DYNA; see the ANSYS LS-DYNA User's Guide for details on parallel processing
options with ANSYS LS-DYNA.
The HPC license options below cannot be combined with each other in a single solution; for example,
you cannot use both ANSYS HPC and ANSYS HPC Pack licenses in the same analysis solution.
See the applicable product documentation for instructions on configuring and running a distributed
solution.
GPU acceleration is allowed when using either ANSYS HPC Licenses or HPC Pack Licenses with the
Mechanical APDL, Mechanical, Polyflow or Fluent applications.
GPU acceleration is available on 64-bit Windows and Linux x64 systems only.
For more information on GPU acceleration, see GPU Accelerator Capability in the Mechanical APDL
Parallel Processing Guide and GPU Accelerator Capability in the Polyflow Users Guide .
ANSYS HPC
These physics-neutral licenses can be used to run multiple analysis jobs across multiple processors and
work with most ANSYS, Inc. applications. The Mechanical APDL, Mechanical and Fluent applications can
utilize any combination of CPU and GPU processors. Other applications are limited to CPU processors only.
Contact your ANSYS sales representative for a complete list of applications that can be used with ANSYS
HPC.
The Mechanical APDL application allows you to use two non-GPU processors without using any
HPC licenses; ANSYS HPC licenses add to this base functionality. For example, a Mechanical APDL
user using twelve processors (or cores) will consume only ten ANSYS HPC tasks.
ANSYS HPC licenses do work with ANSYS Workbench's Remote Solve capability; however, ANSYS
HPC licenses are not subject to single license sharing as described in ANSYS Workbench Licensing
Methods (p. 49).
You cannot combine ANSYS HPC licenses with any other type of HPC licenses, including HPC Pack
Licenses, in the same solution.
ANSYS HPC licenses are not valid with academic products; instead, use the appropriate ANSYS
Academic HPC license.
1 ANSYS HPC Pack License per simulation: Combined CPUs and GPUs not to exceed 8
2 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 32
3 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 128
4 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 512
5 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 2048
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
52 of ANSYS, Inc. and its subsidiaries and affiliates.
Establishing User Licensing Preferences
6 ANSYS HPC Pack License per simulation: Combined CPUs and GPUs not to exceed 8192
7 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 32768
8 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 131072
9 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 524288
10 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 2097152
11 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 8388608
12 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 33554432
13 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 134217728
14 ANSYS HPC Pack Licenses per simulation: Combined CPUs and GPUs not to exceed 536870912
You cannot use more than 14 HPC Pack Licenses on a single analysis. Individual HPC Pack Licenses
cannot be split between multiple users or between multiple analyses.
Mechanical APDL allows you to use two processors without using any HPC licenses; ANSYS HPC
Pack licenses function independently of this base capability. For example, a Mechanical APDL simu-
lation using a single ANSYS HPC Pack License can access up to eight processors (or cores), as noted
above, and not ten processors (or cores).
HPC Pack Licenses do work with ANSYS Workbench's Remote Solve capability; however, HPC Pack
Licenses are not subject to single license sharing as described in ANSYS Workbench Licensing
Methods (p. 49).
You cannot combine ANSYS HPC Pack Licenses with any other type of HPC licenses, including ANSYS
HPC licenses, in the same solution.
ANSYS HPC Pack Licenses are not valid with academic products.
One ANSYS HPC Pack License can be borrowed at a time. Multiple HPC Pack Licenses or other HPC
licenses cannot be borrowed.
You cannot combine physics-specific HPC licenses with any other type of HPC licenses, including
ANSYS HPC or HPC Pack Licenses, in the same solution.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 53
End-User Settings
HPC Parametric Packs enable a specific number of simultaneous design points, as follows:
You can use a maximum of five HPC Parametric Pack licenses per design study.
HPC Parametric Packs also work in conjunction with ANSYS HPC and ANSYS HPC Pack Licenses. Use the
HPC licenses to enable multiple parallel processes to be used for each design point.
For more details on working with HPC Parametric Pack licenses in ANSYS Workbench, see Using HPC
Parametric Pack Licenses in the Workbench User's Guide.
Additional Restrictions HPC Parametric Pack licenses have the following additional restrictions:
HPC Parametric Pack licenses apply to specific ANSYS, Inc. commercial licenses only; see your ANSYS, Inc.
sales representative for a complete list of applicable licenses.
HPC Parametric Pack licenses are supported only on platforms supported by ANSYS Workbench.
HPC Parametric Pack licenses are not supported for Explicit Dynamics.
HPC Parametric Pack licenses do not work with ANSYS Academic products.
HPC Parametric Pack licenses do not interact with Ansoft licenses hosted in ANSYS Workbench.
If the ANSWAIT environment variable is not set, then the ANSYS process will terminate with the following
message in the event all ANSYS licenses are checked out. This is the default condition.
Licensed number of users already reached (-4,132)
The License Queuing option may not be available on all products and may not work as expected with
job scheduling software.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
54 of ANSYS, Inc. and its subsidiaries and affiliates.
Borrowing Application Licenses on Windows
License borrowing is available only if you have borrowable licenses and only on Windows machines;
however, the license server machine that is managing the licenses can be any system that ANSYS, Inc.
supports as a license server. You cannot run both borrowed and non-borrowed licenses simultaneously.
For example, if you borrow licenses but remain connected to a network from which you can use licenses,
you will be able to use only the borrowed licenses. Likewise, if the machine on which you borrowed li-
censes is also a license server from which you could normally use licenses, you would be able to use
only the borrowed licenses. You can borrow only one task of any particular license.
2. Launch the client license borrowing utility: Start > All Programs > ANSYS 16.2 > ANSYS Client Licensing
> Client ANSLIC_ADMIN Utility 16.2. Select Run the ANSYS Borrow Utility.
3. On the Borrow tab, specify the version number and return date. The return date defaults to the third day
from the current date.
If you change any of the borrowing criteria, the product list will automatically update in five seconds.
To update the list immediately, click the Update Delay (sec) button.
4. Select the product(s) you want to borrow. The product list includes add-on features or geometry interfaces.
If you do not see a product listed that you think should be available, verify that you have selected the
correct version.
5. Click Borrow.
6. Disconnect from the network. Note that even when you've disconnected from the network, you must still
run the products from the same account you used to borrow the licenses. For example, if you use a network
account to borrow the licenses, you cannot then run from a local account.
Be sure to verify that you can run the correct product with the borrowed licenses from your machine
AFTER you've disconnected from the network. If you encounter any difficulties, reconnect to the
network, return the license, and then re-borrow the correct license.
If you keep a license for the full amount of time, there is no need to check the license back in. Your
borrowed license will simply expire at the end of the borrow period, and the license will be released
into the pool of available licenses.
1. Reconnect to the same license server from which you borrowed the license(s).
2. Launch the client license borrowing utility: Start>All Programs> ANSYS 16.2> ANSYS Client Licensing>
Client ANSLIC_ADMIN Utility 16.2. Select Run the ANSYS Borrow Utility.
3. Select the Return tab. Click Return all. If you want to keep some but not all of the licenses you borrowed,
you will need to re-borrow them.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 55
End-User Settings
The license(s) you borrowed will be returned to the pool of available licenses.
Note
You must return borrowed licenses from the same account you used to borrow the licenses
originally.
Some multi-feature products include other products and/or add-on features. The utility will automatically
check out any such included products or add-on features. If you borrow one of these multi-feature
products and then click on the Return tab, you will see the product you selected, as well as any other
products and add-ons that it includes. If you return a multi-feature product early, these products and
add-on features will also be returned.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
56 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 5: License Administration Using ANSLIC_ADMIN
For basic license administration, use the ANSYS License Management Center (LM Center). (See License
Server Administration Using ANSYS License Management Center (p. 31) for more information). Some
of the more advanced options have not yet been migrated. This chapter explains how to use the AN-
SLIC_ADMIN utility to perform many of the advanced procedures necessary to administer licenses.
On Windows license server machines, you will have access to a server (full) version of the ANSLIC_ADMIN
utility and an additional client version. The option descriptions below note which options are available
on the Client ANSLIC_ADMIN utility as well as the Server ANSLIC_ADMIN utility.
The Server ANSLIC_ADMIN utility is accessed via Start> All Programs> ANSYS, Inc. License Manager>
Server ANSLIC_ADMIN Utility and updates the ansyslmd.ini file in the global license directory
that resides at <os drive>\Program Files\ANSYS Inc\Shared Files\Licensing by
default. The Server ANSLIC_ADMIN offers access to all options and should be used to administer all li-
censes across a site that use that machine as a license server machine. Changes made using the Server
ANSLIC_ADMIN utility will affect all users who use that machine as a license server machine, where
appropriate. Note that settings such as Specifying the License Server Machine are always local settings
and do not affect other machines, even on a license server.
From a client machine, you will have access to a limited client version of the ANSLIC_ADMIN utility.
The Client ANSLIC_ADMIN utility is accessed via Start > All Programs > ANSYS 16.2 > ANSYS Client
Licensing > Client ANSLIC_ADMIN Utility 16.2 and updates the ansyslmd.ini file in the licensing
directory that resides with the product installation. The Client ANSLIC_ADMIN utility should be used
only to make changes to that local machine's configuration. Changes made using the Client ANSLIC_AD-
MIN utility will affect only this machine and will not affect other users.
On Linux machines, you can access only the full version of ANSLIC_ADMIN; no client version is available.
Some options may apply to Linux or Windows systems only and are so noted.
See Advanced Licensing Configuration Options (p. 19) for details on configuring your license server to
use LMTOOLS or FLEXNet Manager to manage FlexNet. For more information on advanced FlexNet
operations, open the ANSYS License Management Center and select View FlexNet Licensing Guide.
To change the language to a localized version of the utility, first issue the following command with the
-setliclang option. On Windows, run:
"<os drive>\Program Files\ANSYS Inc\Shared Files\Licensing\licadmin\anslic_admin.bat"
-setliclang language
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 57
License Administration Using ANSLIC_ADMIN
On Linux, run:
/ansys_inc/shared_files/licensing/lic_admin/anslic_admin -setliclang language
This command changes the language used for both the server ANSLIC_ADMIN utility and the ANSYS,
Inc. Licensing Interconnect log file. Use the language directory name in the language subdirectory of
the licensing directory (en-us, fr, de, etc.) as the language value. This option is valid only with the
server ANSLIC_ADMIN. Then launch the ANSLIC_ADMIN utility using the above methods.
Important
Changing the language will affect all users of the server ANSLIC_ADMIN utility and the ANSYS,
Inc. Licensing Interconnect. Verify with your licensing system administrator before making
this change.
To change the language setting locally for only the current session of the server or client ANSLIC_ADMIN
utility, you can launch the utility using the -lang option:
<os drive>:\Program Files\ANSYS Inc\Shared Files\Licensing\licadmin\anslic_admin
-lang language
or
/ansys_inc/shared_files/licensing/lic_admin/anslic_admin -lang language
Windows 7 Administrator Privileges On Windows 7 machines, you need to always run these AN-
SLIC_ADMIN options as an administrator, preferably with UAC turned off. If UAC is on, even as admin-
istrator, you must right-mouse click on the ANSLIC_ADMIN selection from the Start menu and choose
Run as administrator.
Windows 8.1 Administrator Privileges On Windows 8.1 machines, you need to always run these
ANSLIC_ADMIN options as an administrator. Additionally, you should right-mouse click on the AN-
SLIC_ADMIN selection from the Start menu and choose Run as administrator.
See the User Account Control (UAC) section of the ANSYS, Inc. Windows Installation Guide for more details
on working with Windows and UAC.
We do not recommend running the ANSLIC_ADMIN on Windows machines by double-clicking the ex-
ecutable directly, especially on Windows 7 or 8 systems. Doing so could launch the utility with unexpected
permission levels.
To use the utility, select an action from the list of buttons on the left.
Launch the ANSYS License Management Center (p. 59) (Server Option)
Run the ANSYS Borrow Utility (p. 63) (Windows only) (Client Option)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
58 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
View the ANSYS Licensing Interconnect Debug Log File (p. 69) (Server Option)
View the ANSYS FlexNet Debug Log File (p. 69) (Server Option)
From the Tools menu, you can select Set Language Options (server only) and then choose a different
language in which to view the server ANSLIC_ADMIN utility and the ANSYS, Inc. Licensing Interconnect
log file. You must close and reopen the ANSLIC_ADMIN utility for this setting to take effect. This option
is valid only with the server ANSLIC_ADMIN.
About ANSLIC_ADMIN
This option is available for both the server and client versions of ANSLIC_ADMIN on Windows machines.
In most situations, you should use the client version. The client version is appropriate regardless of
where you have installed the product. You should use the server version of this option only to specify
the license server machines for Release 11.0 and lower versions. You can also use the server version to
specify license server machines if you have installed the product into <os drive>\Program Files,
but we recommend using the client version anytime you are working with the current release.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 59
License Administration Using ANSLIC_ADMIN
If the product is installed in <os drive>\Program Files (by a user with administrative privileges),
you must have administrative privileges in order to add or modify your server specification. If you are
running on a Windows 7 machine, you must run as an administrator, preferably with UAC turned off.
If you are running with UAC turned on, you must launch ANSLIC_ADMIN using the Run as adminis-
trator option. If you are running on a Windows 8.1 machine, you must run as an administrator. Addi-
tionally, you must launch ANSLIC_ADMIN using the Run as administrator option. For more information,
see the User Account Control (UAC) section of the ANSYS, Inc. Windows Installation Guide for more details
on working with Windows and UAC.
To add a server:
3. Enter the ANSYS Licensing Interconnect and FlexNet port numbers (2325 and 1055 by default, respectively).
Specify the number of servers and enter the host name(s) of your license server(s). You cannot enter a
path or a filename in place of the hostname.
To specify multiple single servers, click OK on this screen after adding the first server. Then click
the Add Server Machine Specification button again and add information for the next server. Repeat
this process for each single server.
To specify redundant triad servers, click the 3-server (redundant triad) option and enter the
hostname for each of the three servers in the spaces available.
4. Click OK.
To delete a server, highlight the server in the list and click Delete Selected Server Machine.
To edit a server, click on one of the listed servers and click Edit Selected Server Machine. You can
then change the ANSYS Licensing Interconnect and the FlexNet port numbers, the number of license
servers, or the hostname(s).
The ansyslmd.ini File The Specify the License Server Machine option creates or updates the an-
syslmd.ini file that is located in the licensing directory. Entries in the ansyslmd.ini file tell ANSYS,
Inc. products which license server(s) to query to find a valid license. Using this option allows all users
at your site to use this setting without having to individually set the ANSYSLMD_LICENSE_FILE or
ANSYSLI_SERVERS environment variables to specify the license server machine(s). It also eliminates
the need to have a copy of the license file on every system at your site.
The order that the SERVER lines are listed in the ansyslmd.ini file dictates the order in which the
license request is granted. To reorder the entries in the list, highlight a server and use the Move up or
Move down buttons.
You are not limited to designating one set of license server machines for your network. You can have
multiple single-server or three-server (redundant triad) licensing systems on your network. In this situation,
you would have certain licenses connected to a set of server machines (one or three) on the network,
and other licenses connected to a different set of server machines (one or three) on the network.
The format of the ansyslmd.ini file created by ANSLIC_ADMIN follows. Each server's specification
entry in this file will typically begin with ANSYSLI_SERVERS= and SERVER= to specify the Licensing In-
terconnect and FlexNet port numbers, respectively.
On a single server:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
60 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
ANSYSLI_SERVERS=<ansysliport>@<host>
SERVER=<flexnetport>@<host>
For multiple single servers, each server should have its own ANSYSLI_SERVERS= and SERVER= lines.
Do not use commas as separators; use colons (:) on Linux machines and semicolons (;) on Windows
machines.
The ANSYS Licensing Interconnect default port number is 2325 and the ANSYS FlexNet default port
number is 1055. The host is the license server hostname. For example, if the license server name is alpha1:
ANSYSLI_SERVERS=2325@alpha1
SERVER=1055@alpha1
The order of the ANSYSLI_SERVERS and the SERVER lines in the ansyslmd.ini file specifies the order
in which the requested license will be granted.
You must use the port@host format; you cannot enter a path or a filename in place of the hostname.
Overriding the ansyslmd.ini File If you want to override the server specification settings in the an-
syslmd.ini file, you can do so by setting the ANSYSLMD_LICENSE_FILE and ANSYSLI_SERVERS
environment variables on individual machines. These environment variables are useful if you want to
temporarily point to a different license server machine without disrupting the machine's configuration.
Use the ANSYSLI_SERVERS environment variable to specify the Licensing Interconnect port number.
Use the ANSYSLMD_LICENSE_FILE to specify the FlexNet port number.
To have your license server preference known each time you log in, set the environment variables AN-
SYSLMD_LICENSE_FILE and ANSYSLI_SERVERS (both Windows and UNIX systems). On UNIX systems,
place these environment variables in your login startup file (e.g., .cshrc file).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 61
License Administration Using ANSLIC_ADMIN
of ANSYS Multiphysics with the server ENG1, and all users in the Engineering Department run on ENG1.
The ansyslmd.ini file states ANSYSLI_SERVERS=2325@DES1 and SERVER=1055@DES1 for the Design
Department, and ANSYSLI_SERVERS=2325@ENG1 and SERVER=1055@ENG1 for the Engineering Depart-
ment. These settings limit users in each department to work only on their own server. If individual users
in the Design Department need to run on the engineering server, ENG1, they could set the following
environment variable:
setenv ANSYSLMD_LICENSE_FILE 1055@ENG1
This example would automatically use 2325@ENG1 for the Licensing Interconnect license path. For this
example, you would need to set ANSYSLI_SERVERS only if you were not using the default Licensing
Interconnect port number.
Solver
PrepPost
Geometry
HPC
You control the order in which the system attempts to check-out a license by moving the licenses up
and down in the list using the Move Up or Move Down buttons. When you open an application, the
license manager attempts to check-out the license listed first in the list. If unable to check-out that license,
then the license manager attempts to check out the next license in the list that can be used by the
application. The license manager will continue through the list until an available license is found. If
none are found, a message displays.
By default, all licenses available from your license server are shown and marked as available for use. If
you do not want a particular license to be available for your use, select the license in the list, and set
the Use/Don't Use field to 0.
If you received a new license, you may need to reset your preferences. If you had previously set your
license preferences using this option, add the new license to your list in the desired order.
If you have made changes to your license preferences, you can return the settings to the default state
by selecting the Reset to Default button.
When you have completed your changes, click OK to make the changes and close the dialog box. Click
Apply to make the changes without closing the dialog box. Selections you make here will take effect
with any new sessions/license checkouts but will not affect the current session or change the license(s)
currently in use.
ANSYS Workbench users can also specify whether to use the shared or separate licensing method.
For details on setting user license preferences, including shared vs. separate licensing for ANSYS Work-
bench and specifying HPC licensing settings, see Establishing User Licensing Preferences in End-User
Settings.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
62 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
License borrowing is available only if you have borrowable licenses and only on Windows machines;
however, the license server machine that is managing the licenses can be any system that ANSYS, Inc.
supports as a license server. You cannot run both borrowed and non-borrowed licenses simultaneously.
For example, if you borrow licenses but remain connected to a network from which you can use licenses,
you will be able to use only the borrowed licenses. Likewise, if the machine on which you borrowed li-
censes is also a license server from which you could normally use licenses, you would be able to use
only the borrowed licenses.
You can use the optional FlexNet options file settings to further control borrowing at your site. To use
these settings, you must first specify which users are allowed to borrow licenses by adding an IN-
CLUDE_BORROW group to the options file. Any user not in the INCLUDE_BORROW group will not be
allowed to borrow licenses. You may also want to set up an EXCLUDE_BORROW group to prevent spe-
cific users from borrowing licenses.
You can also limit the number of licenses that can be borrowed from your total pool of borrowable li-
censes. Set the BORROW_LOWWATER option in the options file to the number of licenses that cannot
be borrowed. For example, if you have 15 licenses total and want to limit the number that can be bor-
rowed to 5, set BORROW_LOWWATER=10.
The maximum number of hours a license can be borrowed at any one time is defined by your license
file. You can set that limit lower for your users by setting the MAX_BORROW_HOURS option in the options
file. MAX_BORROW_HOURS cannot exceed the limit specified in your license file. The total maximum
number of borrowable hours is defined by your license agreement.
Compatibility between versions Flexera Software has created an incompatibility in license borrowing
between FlexNet releases. Since different versions of FlexNet are used at most releases, the borrowed
licenses are not compatible between different ANSYS releases. The ANSBORROW utility includes a selection
for the ANSYS version you are planning to run using the borrowed license. Choose your version carefully,
because you will only be able to run one of the versions at a time with borrowed licenses.
The ANSBORROW utility allows you to borrow either initial release or service pack (SP) versions. The SP
versions for a given platform use the same FlexNet version as the initial release; therefore, licenses se-
lected for an SP should work for the initial release.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 63
License Administration Using ANSLIC_ADMIN
2. Launch the client license borrowing utility: Start > All Programs > ANSYS 16.2 > ANSYS Client Licensing
> Client ANSLIC_ADMIN Utility 16.2. Select Run the ANSYS Borrow Utility.
3. On the Borrow tab, specify the version number and return date. The return date defaults to the third day
from the current date.
If you change any of the borrowing criteria, the product list will automatically update in five seconds.
To update the list immediately, click the Update Delay (sec) button.
4. Select the product(s) you want to borrow. The product list includes add-on features or geometry interfaces.
If you do not see a product listed that you think should be available, verify that you have selected the
correct version.
5. Click Borrow.
6. Disconnect from the network. Note that even when you've disconnected from the network, you must still
run the products from the same account you used to borrow the licenses. For example, if you use a network
account to borrow the licenses, you cannot then run from a local account.
Be sure to verify that you can run the correct product with the borrowed licenses from your machine
AFTER you've disconnected from the network. If you encounter any difficulties, reconnect to the
network, return the license, and then re-borrow the correct license.
If you keep a license for the full amount of time, there is no need to check the license back in. Your
borrowed license will simply expire at the end of the borrow period, and the license will be released
into the pool of available licenses.
1. Reconnect to the same license server from which you borrowed the license(s).
2. Launch the client license borrowing utility: Start > All Programs > ANSYS 16.2 > ANSYS Client Licensing
> Client ANSLIC_ADMIN Utility 16.2. Select Run the ANSYS Borrow Utility.
3. Select the Return tab. Click Return all. If you want to keep some but not all of the licenses you borrowed,
you will need to re-borrow them.
The license(s) you borrowed will be returned to the pool of available licenses.
Note
You must return borrowed licenses from the same account you used to borrow the licenses
originally.
Some multi-feature products include other products and/or add-on features. The utility will automatically
check out any such included products or add-on features. If you borrow one of these multi-feature
products and then click on the Return tab, you will see the product you selected, as well as any other
products and add-ons that it includes. If you return a multi-feature product early, these products and
add-on features will also be returned.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
64 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
Release 11.0: Selecting this option affects the product ordering for Release 11.0 for this machine (including
all users who run a Release 11.0 product on this machine or mount to this machine). If you select this option,
the product ordering you specify will NOT affect any releases after 11.0.
Release 12.0 and higher: Selecting this option affects the product ordering for Releases 12.0 or later and is
applicable ONLY if this machine is a license server machine. The product ordering you select with this option
will affect all users who use this machine as a license server machine.
After you choose a release level, click OK. You will then need to select the installation directory (Release
11.0 only), product category (Solver, PrepPost, Geometry, or HPC). To re-order the products, select a
product and click the Move up or Move down button. When you have finished reordering all products
that you want to reorder, click Save and then Close.
All products available in a given category are shown, regardless of whether you have licenses for them.
If you have made changes to your product ordering, you can return the settings to the default state by
selecting the Reset to Default button.
For Release 12.0 and higher, after making changes to the product order (including resetting to the de-
fault), you will need reread the license file or restart the license manager for the changes to take effect.
Only those logged in as root or superuser (Linux) or with administrative privileges (Windows) can use
this utility. You should set the product order before any of the users at your site run; once a user sets
his preferences, the user preferences will take precedence.
Note
After upgrading the License Manager, if you have specified a product order in a previous
release you must re-run the Specify Product Order option and re-specify your required product
order.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 65
License Administration Using ANSLIC_ADMIN
Note
Only those users who are logged in as root or superuser (Linux) or with administrative priv-
ileges (Windows) can use this utility.
Use this option to modify your license manager startup options. License manager startup options that
you can modify include:
STANDARD level logs ansysli_server STARTUP options, license cache information (such as fea-
tures/counts and FlexNet options file content), CHECKOUT, CHECKIN, RESERVE, and RETURN_RESERVE.
It also logs CLIENT_SHUTDOWN for all but ansysli_monitor.
CONNECTIONS level logs everything that STANDARD logs, and CLIENT_ACCEPT and CLIENT_SHUTDOWN
for the monitor.
VERBOSE level logs STANDARD plus CONNECTIONS, and ADD (product definitions and shared capabilities)
and REMOVE (shared capabilities).
FlexNet Options
You can specify the path to the FlexNet debug log file (license.log, by default). By default, a new li-
cense.log file is created each time you start the license manager; you can choose to have new inform-
ation appended to the existing file instead.
The -local option restricts the ability to shut down the FlexNet components of the license manager
to only an administrator running on the same machine where the FlexNet components of the license
manager was started. This option is off by default. See the FlexNet License Administration Guide for
more information on using this option.
The -local option is not recommended if you will be using license borrowing.
Miscellaneous Options
You can specify the ANSYS Licensing Interconnect port number here. The default port number is 2325.
All machines that have this server machine in their Licensing Interconnect paths must use the same
port number. If you change the Licensing Interconnect port number here, and other machines use
this machine's Licensing Interconnect, then on each of those machines, you must change the Licens-
ing Interconnect port number by one or both of the following options, as appropriate for your
configuration:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
66 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
You can also disable the ability to reserve licenses for a design point study in ANSYS Workbench
and/or the users' ability to track licenses used by ANSYS Workbench. For more information on re-
serving licenses for design point studies in ANSYS Workbench, see Reserving Licenses for Design Point
Studies in the ANSYS Workbench documentation.
On Linux machines only, you can also specify who can shut down the ANSYS, Inc. License Manager.
By default, anyone can stop the license manager. You can restrict shutdown capabilities to only the
user who started it, or to a group, such as lmadmin. If you choose group, you will need to specify
the name of the group. If you specify a group restriction, any users in that group who want to stop
the license manager must have the specified group as their primary group. Note that the user who
started the license manager will still be able to shut it down, even if he is not part of a group with
shutdown capabilities.
Warning
The license.log file and the ansysli_server.log file for each server should be
located on a local disk. Writing to an NFS-mounted disk or remote file server creates a situ-
ation where the license server(s) may fail. If the remote system containing these files crashes,
the license manager would be unable to log license transaction data. This would create a
fatal error condition.
Note
Only those users who are logged in as root or superuser (Linux) or with administrative priv-
ileges (Windows) can use this utility.
1. On the Specify License Servers to Cache dialog, click Add Server Machine Specification.
2. On the Specify License Servers to Cache - Edit Selected Server Machine dialog box, enter the Licensing
Interconnect port number. The default Licensing Interconnect port number is 2325.
4. Click OK.
5. Repeat steps 1 - 4 for any additional servers that you want to cache.
6. When you have finished specifying servers, click Close on the Specify License Servers to Cache dialog.
To delete a cached server, highlight the server in the list and click Delete Selected Server Machine.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 67
License Administration Using ANSLIC_ADMIN
To edit a cached server, click on one of the listed servers and click Edit Selected Server Machine. You
can then change the ANSYS Licensing Interconnect port number or the hostname(s).
View the ANSYS Licensing Interconnect Debug Log File (p. 69)
(Server Only)
(Server Only)
(Server Only)
When you select one of these options, the data will appear in the log area on the right side of the
utility. Display the Customer Number appends the customer number to the session log itself; the
other options create their own display in the log area. Each option is explained in the following sections.
Where the first line shows information for the requesting user, and subsequent lines under that capab-
ility show information for the users who are currently using the licenses for each of the licensed products
that satisfy the requested capability.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
68 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the ANSLIC_ADMIN Utility
An example report is shown below. Each line is numbered for reference in the discussion following the
example. Note that the actual report does not contain line numbers.
Capability Product Timestamp User Count Host PID Platform
1 ANS_SOLVER 2010/04/27 09:39:27 JQD 1 mach1.win.acme.com 1234 winx64
2 ane3fl 3
3 2010/04/27 08:01:10 JXS 1 mach2.win.acme.com 5678 winx64
4 2010/04/27 07:29:13 MQD 2 mach3.win.acme.com 8765 winx64
Line 1: User JQD is running a process, 1234, on the machine mach1.win.acme.com, which has requested
one license with the ANS_SOLVER capability.
Line 2: Based on the site/user preferences, the ane3fl product can satisfy the requested capability, and
this site/user is permitted to use up to 3 licenses of this product.
Line 3: User JXS has been using 1 of the available licenses since 8:01:10, from machine
mach2.win.acme.com, running process number 5678.
Line 4: User MQD has been using 2 of the available licenses since 7:29:13, from machine
mach3.win.acme.com, running process number 8675.
Since users JXS and MQD are already using all of the available licenses, user JQD must either wait for
one of those licenses to be freed, or contact one of those users and request that a license be freed.
Select the Auto-Refresh button to have the information automatically refresh every five (5) seconds.
You can also display the queuing report via command line, without launching the ANSLIC_ADMIN
utility. To do so, run the following command on Windows systems:
"C:\Program Files\ANSYS Inc\Shared Files\Licensing\licadmin\anslic_admin" -queueinfo
If you need to view the queuing report frequently, you may find it convenient to set a desktop shortcut
using the above command.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 69
License Administration Using ANSLIC_ADMIN
This feature is useful if you want to easily review the files from a single location, or if you need to
compress the files and send them to a technical support representative. Every time you choose to
gather these files, you are prompted to specify the path of the diagnostics directory or to accept the
default location. If you do not define the path of the diagnostics directory, the log and error files will
be copied into a new, date-stamped subdirectory in your $HOME/.ansys directory on Linux or in the
directory specified by the TEMP environment variable on Windows. Be aware when choosing this option
that some of these files can be large and could require significant disk space. You may want to delete
these directories when you are finished reviewing them because of the disk space usage.
After all relevant files are gathered (if selected), this option runs the ansys_pid utility, which queries the
system for information that may be useful for troubleshooting certain problems. This operation may
take a few minutes. You can append this information to the session log, or you can write it out directly
to a file using the buttons at the bottom of the window.
When you run this ansys_pid utility, information about your licensing information is displayed in the
ANSLIC_ADMIN log area. Information displayed may include:
firewall information
The contents of specific log and error files will not be displayed in the ANSLIC_ADMIN log area. You
will need to review these files individually for specific errors and other status/log information.
Note
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
70 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 6: Using Dongles with the ANSYS License Manager
This section explains dongle and dongle driver support and usage with ANSYS, Inc. products at Release
16.2. The information applies to the ANSYS License Manager only and does not apply to any other license
managers that you may be using. The following procedures assume that you have some familiarity with
dongles, their usage, and their advantages and disadvantages.
ANSYS, Inc. supports only FLEXID9 (Sentinel/Aladdin USB) dongles and their Flexera-provided drivers.
ANSYS does not support license borrowing for any license features tied to a dongle.
When we refer to dongles, we are specifically referring to FLEXID9 (Sentinel/Aladdin USB) dongles.
Every machine from which you are serving licenses tied to a dongle requires the following:
Dongle driver and associated FlexNet-provided FLEXID9 library are installed on the machine.
Only the dongle drivers that are included as part of our installation files are fully supported by ANSYS,
Inc. We strongly recommend that you use these drivers. If you use any other version of the driver, ANSYS,
Inc. can provide only limited support if you encounter problems. Flexera has stated that they will not
provide any support for drivers other than those that we include with our installation.
Due to requirements of non-ANSYS products that are installed on the machine or because of operating
system levels that ANSYS, Inc. supports but the drivers included in the ANSYS installation do not, you
may need to use a version of the drivers other than those that we provide. You will need to choose
which driver to use based on your individual business needs. Unfortunately, we cannot ensure that our
license manager will work with that driver.
All ANSYS paths shown in this document show the default installation directory. If your installation
directory is not the default location, replace all ANSYS paths with your installation directory. The default
installation directories are as follows:
In addition to installing the dongle driver, a Flexera-provided FLEXID9 library must also be installed
before FLEXID9 dongles will be recognized. The ANSYS License Manager installation's licensing config-
uration process handles this step for Windows machines. On Linux, copying this file to the correct loc-
ation is a manual step included in the Linux section below.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 71
Using Dongles with the ANSYS License Manager
Zip File Driver Installation File FlexNet FLEXID9 Shared FlexNet Version
Library
11.12.1.1.zip haspdinst.exe, version haspsrm_win64.dll, version 7.1 11.12.1.1
6.61
Zip File Driver Installation File FlexNet FLEXID9 Shared FlexNet Version
Library
11.12.1.2.tar aksusbd-2.4-1.i386.rpm, libhasp_linux_x86_64.so, version 11.12.1.2
version 2.4 7.1
Caution
Do not allow Windows Update to install later versions of the dongle driver as this is not
the Flexera-provided version. Automatic updates can cause unpredictable behavior with
dongles, such as:
The dongle driver cannot be removed using the methods described in this document.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
72 of ANSYS, Inc. and its subsidiaries and affiliates.
Windows Procedures
2. Confirm that the license manager is stopped by verifying that the 'ANSYS, Inc. License Manager' service is
not running.
3. Remove all FLEXID9 dongles attached to your machine. Do not attach any dongles to the system again
until told to do so in this document; if a dongle is plugged in before you have completed the driver install-
ation, the Windows operating system could automatically install a non-Flexera driver.
Caution
Removing drivers or dongles may seriously disrupt your ability to run products asso-
ciated with those dongles. Do not remove any dongles or dongle driver until you
determine that it is safe to do so. Always stop the license manager and remove the
dongle from the system before removing any existing driver.
4. Remove any existing driver on your system. See the Removing an Existing Dongle Driver on Windows (p. 74)
section below for more information.
6. Extract the contents of the 11.12.1.1.zip file into C:\Program Files\ANSYS Inc\Shared
Files\bin\winx64\drivers\flexnet. You will need to remove 11.12.1.1 from the end of the default directory
shown, if it is included.
7. Open an administrator command prompt window and perform the following steps:
haspdinst.exe -install
Note
You may not see the new driver until the dongle has been inserted into the machine.
However, do not insert the dongle until the next step.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 73
Using Dongles with the ANSYS License Manager
10. To see if the dongle is being recognized, open the ANSYS License Management Center and click the Get
System Hostid Information link. If the dongle is recognized, you will see a FLEXID9 Dongle ID (F) entry
under the IDTYPE column. (You can open the ANSYS License Management Center by clicking the ANSYS,
Inc. License Manager > ANSYS License Management Center item on the Windows Start Menu/Apps
Page.)
Caution
Removing drivers or dongles may seriously disrupt your ability to run products associated
with those dongles. Do not remove any dongles or dongle drivers until you determine
that it is safe to do so. Always stop the license manager and remove the dongle from
the system before removing any existing driver. Do not attach the dongle to the system
again until told to do so in this document.
1. Before installing the ANSYS-supplied driver, you must remove any existing driver from your system. You
will need to use the installer or removal utilities provided with that driver to remove it. See the document-
ation provided with that driver for specific commands or procedures, or if you encounter problems.
If the dongle driver has been updated by Windows Update, it must be removed using the tools
provided by SafeNet, Inc. See SafeNets documentation for details.
2. The FLEXID_Dongle_Driver_Installer.exe file was the driver installation file that ANSYS, Inc.
provided prior to Release 16.2. If you used it to install an earlier version of the ANSYS-supplied dongle
driver, run the following command while in the 11.9.1.0 subdirectory to remove it:
FLEXID_Dongle_Driver_Installer.exe /remove
If you used the FLEXIDInstaller.exe file to install an earlier version of the dongle driver, you
can use either the cleanup utility provided for use with the FLEXIDInstaller utility or use the Add
or Remove Programs option from the Windows Control Panel. To use the cleanup utility, run the
following command while in the 11.9.1.0 subdirectory:
FLEXIDCleanUtility.exe
If, for some reason, you wish to remove the dongle driver supplied at Release 16.0, run the following
command while in the 11.12.1.1 subdirectory to remove it:
haspdinst.exe -remove
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
74 of ANSYS, Inc. and its subsidiaries and affiliates.
Linux Procedures
3. Remove all FLEXID9 dongles attached to your machine. Do not attach any dongles to the system again
until told to do so in this document.
Caution
Removing drivers or dongles may seriously disrupt your ability to run products asso-
ciated with those dongles. Do not remove any dongles or dongle driver until you
determine that it is safe to do so. Always stop the license manager and remove the
dongle from the system before removing any existing driver.
4. Remove any existing driver on your system, if necessary. See the Removing an Existing Dongle Driver on
Linux (p. 76) section below to determine if you must remove an existing driver.
/ansys_inc/shared_files/bin/linx64/drivers/flexnet
7. Go to the subdirectory containing the 11.12.1.2.tar file's contents, and do the following:
Note
If this file already exists in the /usr/lib directory, rename it before copying the
file.
rpm -i ./aksusbd-2.4-1.i386.rpm
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 75
Using Dongles with the ANSYS License Manager
10. To see if the dongle is recognized, open the ANSYS License Management Center and click the Get System
Hostid Information link. If the dongle is recognized, you will see a FLEXID9 Dongle ID (F) entry under the
IDTYPE column. You can bring up the ANSYS License Management Center by running the following
script:
/ansys_inc/shared_files/licensing/start_lmcenter
Caution
Removing drivers or dongles may seriously disrupt your ability to run products associated
with those dongles. Do not remove any dongles or dongle driver until you determine
that it is safe to do so. Always stop the license manager and remove the dongle from
the system before removing any existing driver. Do not attach the dongle to the system
again until told to do so in this document.
Before installing the new driver, you must determine whether an existing driver must first be uninstalled.
If the existing driver was installed via the script method (i.e., using the dinst script provided with the driver)
rather than by using the rpm method, you may not need to remove the currently installed driver before in-
stalling the new driver. The rpm installation method that will be used to install the new driver should replace
the existing driver with the new driver. If you decide to uninstall this driver, you must use the dinst script
that you used to install it.
If the existing driver was installed via the rpm method, you must uninstall this driver before installing the
ANSYS-supplied driver.
If you have installed the new driver, rebooted the machine, and attached the dongle to the system, but the
dongle is not recognized, confirm that the following file exists in the location below:
Linux: /usr/lib/libhasp_linux_x86_64.so
If the file is missing, copy the installation's file with that name from the ANSYS FlexNet drivers directory
to the required location for your machine's platform.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
76 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 7: Troubleshooting
This chapter lists problems and error messages that you may encounter while setting up licensing. After
each situation description or error message is the user action required to correct the problem.
For more troubleshooting information, see the FlexNet License Administration Guide (accessible from the
ANSYS License Management Center).
View the licdebug file. The licdebug file is generated when you run an ANSYS, Inc. application and
resides in the .ansys subdirectory under the directory specified by the TEMP environment variable (Win-
dows) or in the $HOME directory (Linux). The licdebug filename will vary depending on the product but
will follow the format licdebug.<product>.162.out. For example:
If a licdebug file already exists and is dated today, the information is appended. If it is dated before
today, the existing file will be renamed with a .old extension and a new file will be started.
Mechanical: licdebug.MECH.162.out
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 77
Troubleshooting
Note
The license debug file names include the current release of the application. Because not
all applications are updated with each release, it is possible to have licedebug file names
that are appended with older release numbers. For example, it is possible to be running
ANSYS Release 16.1 but still have a product license debug log file name include 160 as in
licedebug.POLYFLOW.160.out.
The directory specified by the TEMP environment variable may be hidden on your system. To view
the directory and file, click on My Computer. Choose Tools from the menu, and then click on Folder
options. Click on the View tab and select Show hidden files and folders. Click OK.
If after following these suggestions, the resulting debug information does not make sense, try these
suggestions:
Confirm that the license manager was restarted or the license file was reread after any changes were
made to the license file. If you did not make any changes to the license file for the server, check the
date/time that it was last changed. Get the relevant path information from the debug output. Also,
confirm that the same path is being used.
Try restarting the license manager and then attempt to run again. See if the same situation occurs.
If you installed a new license file but is not seeing it even after restarting the license manager, confirm
that the correct license file is being used to start the license manager. In this case, neither the client
application nor the license manager is using the changed file. Also confirm that if site or user license
preferences were set, the preferences were updated with the new license information.
If the ansyslmd.lic file is at the end of the path and it is a license file that uses the license manager
daemon/service, then confirm that the license manager is started with the same path as the an-
syslmd.lic file's path. The license manager could be looking at one file in the client application but
the license manager daemon/service was started with another file.
The client-related diagnostic information can be gathered by using the Client ANSLIC_ADMIN utility.
For more information, see, Gather Client Diagnostic Information.
The server-related diagnostic information can be gathered by using ANSYS License Management
Center or by using the standalone gatherdiagnostics script. For more information, see, Gathering
Diagnostic Information.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
78 of ANSYS, Inc. and its subsidiaries and affiliates.
Problem Situations
1. Check the license.log file in the licensing directory on the license server for errors. See the re-
mainder of this chapter for a list of possible errors and their resolutions.
2. Check the ansysli_server.log file in the licensing directory on the license server for errors.
3. Verify that TCP/IP is installed and configured correctly. Verify that the IP address is static. See Commu-
nications Requirements (p. 12) for information about configuring TCP/IP.
4. Verify that the hostid has not changed. If the hostid has changed, you must obtain a new license.
Linux x64 systems running the ANSYS, Inc. License Manager require the Linux Standard Base (LSB)
package. If this package is missing, you will see one of the following errors when the license manager
attempts to run:
/lmgrd -h
./lmgrd: No such file or directory
In this case, try installing the LSB package from the Linux installation media.
Three-Server Environment
In a three-server environment, you could see the following message when you start the first server:
This message results when a quorum of servers (2 of the 3) are not yet started. Start the other
servers, or verify that they are already started. When at least two of the three servers are started,
you will see the ANSYS License Management Center of this server change to reflect that it is now
running. Do NOT attempt to stop the license manager by clicking the Stop button in the ANSYS
License Management Center.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 79
Troubleshooting
If you verify that at least two servers are started and the ANSYS License Management Center does
not update to running in a reasonable time, follow the three steps noted in License Manager Will
Not Start (p. 79).
Caution
When you see this message, do NOT click the Start button again.
1. ansysli_monitor
1. If you received a new license but your application does not recognize it, you may need to reset your pref-
erences. If you had previously set your license preferences, select Set License Preferences for User from
the ANSLIC_ADMIN utility and add the new license to your list in the desired order.
2. If you had previously defined your preferences and have since installed the license manager to a different
location, you may need to reset your preferences.
3. If you do not see the correct licenses in the Client ANSLIC_ADMIN's Set License Preferences for User
option or in the Mechanical APDL Product Launcher, and you updated your product order at a previous
release, you may need to update your product order again. Use the Specify Product Order option under
Server ANSLIC_ADMIN's Set Site Preferences.
1. Select the Reset to Default button to see the current release's default product order.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
80 of ANSYS, Inc. and its subsidiaries and affiliates.
Problem Situations
For more information , see Specify Product Order (p. 65) and Establishing User Licensing Prefer-
ences (p. 48).
1. Select the Reset to Default button to see the current release's default product order.
7.3.6. FlexNet Log File Shows Unexpected Messages When the License Manager
Is Stopped
On Windows systems, you may see unexpected error messages in the FlexNet licensing log file when
you shut down the license manager. Messages similar to the following could appear:
13:47:49 (lmgrd) Can't connect to the license server system. Shutdown ansyslmd failed.
13:47:49 ((lmgrd)) 13:47:49 Loop info:(lmgrd) Cannot read data from license server system. (-
16,10009:10054 "WinSock: Connection reset by peer")
MT:0 VD_HB:5913:47:49 (lmgrd) reset:0Can't shutdown the license server system. Shutdown an-
syslmd failed. clients:013:47:49 (lmgrd) fd's:0EXITING DUE TO SIGNAL 15
13:47:49 (lmgrd) manager (lmgrd) will attempt to re-start the vendor daemon.
These or similar messages in the FlexNet log file can be safely ignored in most cases. You can verify
that the service is shown as stopped, and that the ansysli_server, ansysli_monitor, lmgrd,
and ansyslmd processes are stopped via Task Manager.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 81
Troubleshooting
1. Review the Licensing Interconnect debug log file for more information. Use the View Licensing Interconnect
Log option of ANSYS License Management Center to view the file.
2. On the license server machine(s), review the FlexNet license.log file for error messages. Use the View
FlexNet Debug Log option of ANSYS License Management Center to view the file.
3. If neither log file exists or has a zero length, verify that you have write permissions on the files and on the
directory containing the files (the licensing directory by default).
4. If you have borrowed licenses, verify that you are not attempting to check out a non-borrowed license.
Once you have borrowed one or more licenses, you will not be able to use non-borrowed licenses until
you have returned all borrowed licenses. For more information, see Borrowing Application Licenses on
Windows (p. 55)
You could also encounter problems with obtaining a license if the Licensing Interconnect is still attempt-
ing to restart the FlexNet server. Check the FlexNet license.log file. If you see the following lines
multiple times, try rebooting your license server machine:
(lmgrd) ansyslmd exited with status 28 (Communications error)
(lmgrd) Since this is an unknown status, license server
(lmgrd) manager (lmgrd) will attempt to re-start the vendor daemon.
(lmgrd) REStarted ansyslmd (pid 103864)
7.3.9. Jobs Abort When a License Manager Goes Down in Three-Server Envir-
onment
If you are running in a three-server environment and ANSYS program jobs abort when one of the license
managers goes down, perform the tests below in the order they are listed:
Note
1. If this problem persists after you perform the steps below, you may want to consider switching
to a single-server environment.
2. When using a three-server environment, we strongly recommend that all three servers be on
the same subnet. If this is not the case, you should consider using three machines which are in
the same physical location and are on the same subnet.
1. Verify that two of the three license managers are still running. Use the ANSLIC_ADMIN utility (Display
the License Status). If the license manager is not already running on all servers, start it on all of them.
2. Check the ansyslmd.ini file in the licensing directory to make sure the server specification is correct.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
82 of ANSYS, Inc. and its subsidiaries and affiliates.
Problem Situations
4. Verify that the same license file exists on all three license servers in the licensing directory. The hostnames
of all three servers must appear in these files and in the same order. If the license files are not the same on
all three servers, make corrections as necessary and restart the license manager.
5. Verify that the date and time on all license servers are consistent and correct. Make corrections as necessary
and restart the license manager.
6. Verify that the hostid has not changed on any of the license servers. If any hostid has changed, you need
to obtain and install new licenses on all license servers.
7. Verify that the license manager and utilities are installed locally on each license server. If not, run the in-
stallation from the installation media and choose to install the license server only. See the installation
manual for your product and platform for more information.
8. Verify that the ansyslmd.opt files match exactly on all three license servers.
9. Check the FlexNet license.log and the licensing interconnect ansysli_server.log files for error
messages. See the remainder of this chapter for a list of possible errors and their resolutions.
The license manager is down. In this case, use ANSYS License Management Center to start the license
manager.
You are not licensed for the requested product. In this case, request a product for which you are licensed.
All licenses for the requested feature are reserved in the license options file. If so, have the license ad-
ministrator correct the license options file.
The user is excluded via the license options file from using the licenses for the feature(s) that are installed
on this machine.
7.3.12. The FlexNet Utility lmutil Does Not Shut Down License Manager
If you attempt to use the FlexNet utility lmutil from an earlier release (such as the FlexNet 10.8.8
version of the daemons) to shut down the ANSYS, Inc. Release 16.2 License Manager, you may see the
prompt to shut down the license manager repeatedly:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 83
Troubleshooting
lmutil - Copyright (c) 1989-2008 Acresso Software Inc. All Rights Reserved.
[Detecting lmgrd processes...]
Port@Host Vendors
1) 1055@pghxpuser7 ansyslmd
If the current version of the lmutil is not in the licensing directory, the older version of lmutil may
or may not shut down the ansyslmd daemon, but it will not shut down the lmgrd daemon.
To correct this error, use the most current version of lmutil to shut down the license manager.
1. Use the Specify the License Server Machine option of the ANSLIC_ADMIN utility to specify the missing
Licensing Interconnect or FlexNet port number. (On Windows, use the Client ANSLIC_ADMIN utility.) If
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
84 of ANSYS, Inc. and its subsidiaries and affiliates.
Problem Situations
the machine is already specified but the error message states that no FlexNet path has been specified, the
FlexNet port number may be missing from the license server specification shown in the Specify the License
Server window. Add the machine's FlexNet port number using the Specify the License Server Machine
option to add this machine to your FlexNet license path.
Note
This particular machine may have been configured to run the ANSYS Licensing Interconnect
without starting FlexNet. Verify that FlexNet is running on this machine before changing
this setting.
See Specify the License Server Machine (p. 59) for more information on specifying license server
machines.
QT_IM_MODULE
XMODIFIERS
GTK_IM_MODULE
You should reset these environment variables when you are finished running the installation or using
ANSLIC_ADMIN. Do not permanently unset these environment variables as doing so could affect other
applications.
If you want to return a license associated with a specific reserve ID, issue the following ansysli_util
command option to find the reserve ID of the reserved licenses:
ansysli_util -reserve_list
The list of reserve IDs will be displayed. For example, issuing the above command might return output
similar to the following (your output will appear on a single line):
USER LABEL/RESERVE-ID
jqd MyProject(###)(###)634710595285628367 licabc.acme.com--7782-6343374
PRODUCT TASK HOST FlexNet_SERVER
ANSYS Dynamics <dynamics> 19 jqd.win.acme.com--7782-6343374 1055@licabc
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 85
Troubleshooting
RESERVED_DATE
2012/05/01 14:51:43 ANSYS Academic Mechanical HPC 3
Using the reserve ID from the previous command output, issue the following command to remove a
specific reserve:
ansysli_util -return_reserve_by_id id
If you want to return licenses reserved by a specific user, issue the following command:
ansysli_util -return_reserve_by_user username
If you want the ability to return all reserved licenses, use one of the following Licensing Interconnect
startup options:
OR
2. Start the Licensing Interconnect, using the ansyslmd.ini keyword (RETURN_RESERVE=USER) or Licensing
Interconnect command option (-reserveuser) to specify the users who are able to return reserved licenses.
Note that you can also specify by group on Linux, using the Licensing Interconnect command option-re-
servegroup or the ansyslmd.ini keyword RETURN_RESERVE=GROUP. See keyword and command options
in the Reference Section for more information.
Once you are permitted to return reserved licenses, issue the following command to return all reserved
licenses:
ansysli_util -return_reserve_all
This command removes any free or hung licenses in the reserve; if any of the reserved licenses are still
in use, those running jobs will continue to completion. Any licenses checked out by those running jobs
will remain checked out until the jobs complete. The design point study will not start new jobs, since
the reserves have been removed.
Open a command prompt window. (If the machine has UAC enabled, right-mouse click on the Command
Prompt option from the Start menu and select Run as administrator.) Enter the following commands
in the command prompt window:
net stop "ANSYS FLEXlm license manager"
sc delete "ANSYS FLEXlm license manager"
If you see a message stating that access is denied, confirm that your account has administrator privileges
and that you have opened the command prompt window with administrator privileges. It can take
several minutes for the service to be completely removed. Therefore, after you receive the message
stating that the removal of the service was successful, allow several minutes for it to complete.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
86 of ANSYS, Inc. and its subsidiaries and affiliates.
Problem Situations
7.3.21. See a File Not Found Message When Running a Licensing Utility
Linux x64 System: Linux x64 systems running the ANSYS, Inc. License Manager require the Linux
Standard Base (LSB) package. If this package is missing, you will see a message similar to one of the
following errors when the license manager attempts to run, or when you attempt to run a licensing
utility, such as ANSLIC_ADMIN, getFLEXid, or lmutil.
/lmgrd -h
./lmgrd: No such file or directory
If you have confirmed that the file listed does exist, try installing the LSB package from the Linux install-
ation media.
C:\Windows\System32
If the FlexNet dll is not in the Windows\System32 directory, you can manually place it there by copying
it from the following ANSYS installation directory:
ANSYS License Management Center hangs up, displaying the message,Determining license manager
status...
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 87
Troubleshooting
Various Messages
If you see any licensing-related messages, the launcher has encountered an error while trying to
find or retrieve a license. Possible causes are the license manager is not running, no licenses were
found, or the existing licenses have expired. If any of these messages appear, perform the tests that
are listed below in the order presented:
1. Verify that the license manager is running on all license servers by viewing the ANSYS License
Management Center. If the license manager is not running, start it on the license server machine(s).
2. Check the license.log and ansysli_server.log file on each license server for errors.
3. Run Mechanical APDL (ANSYS) from a command prompt to check for additional error messages.
Example (Windows):
"C:\Program Files\ANSYS Inc\V162\ANSYS\bin\winx64\ansys162"
Check the Mechanical APDL (ANSYS) Output window for error messages and additional in-
formation about the failure.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
88 of ANSYS, Inc. and its subsidiaries and affiliates.
Licensing Error Messages
4. Use the ping command to test communication between the client machine and the license server.
If the ping command does not work, modify the hosts file or the DNS server to contain
the correct host names and IP addresses. Verify that the license server and the client ma-
chines have unique IP addresses.
5. Verify that the ansyslmd.ini file exists in the client licensing directory and that it contains the
correct hostname and port numbers of the license server. If this file does not exist, see Specify the
License Server Machine (p. 59) to specify the license server. If the ANSYSLMD_LICENSE_FILE
variable is used to specify the license server, verify that the hostname of the license server is correct.
6. Verify that the correct version of the license manager daemons (lmgrd and ansyslmd) is being
used. For the current version of FlexNet, see Compatibility with Other FlexNet-Licensed Soft-
ware (p. 1)
If you see this message, the simulation environment specified in the named profile was uninstalled
since the profile was created. You will need to specify a new simulation environment and re-specify
any launcher settings to continue. To avoid seeing this message in subsequent launcher sessions,
update and resave the profile, or reinstall the desired simulation environment.
You may have reached the number of ANSYS product tasks that you have licensed. Wait until a task
has been freed up and try again. If this error occurs on a regular basis, you may want to talk to your
ANSYS sales representative about obtaining additional licenses.
This error may also occur when licenses have been reserved for certain users, or when certain users
have been excluded from licenses via the license options file.
This error may occur if you have multiple INCREMENT lines for the same feature in the license file,
and there are differing fields on each INCREMENT line (such as VENDOR_STRING and the version
field), and licenses have been reserved for this feature. In this situation, the number of reserved li-
censes is reserved out of each INCREMENT, rather than the sum total of both.
or
The license manager is currently not running. Use ANSYS License Management Center to start
the license manager. Your license must exist on the license server prior to starting the license
manager.
If you install the license manager and a license file, and it appears that the server is running, but
you cannot connect to your license server, try rebooting.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 89
Troubleshooting
If you think the license manager should already be running, check the FlexNet license log file and
the ansysli_server.log file for errors.
If Windows Firewall is enabled on the license server, ansyslmd.exe, lmgrd.exe, and an-
sysli_server.exe need to be included in the exceptions.
The wrong hostname is in the license file (machine ID is correct in the file and when the license
keys were generated). The license manager could not be started.
The wrong license file is on the system (both hostname and machine ID are incorrect and the license
keys were created with the wrong ID). The license manager could not be started.
The wrong license file is on the system AND the user changed the server line to have the machine's
hostid but not the hostname. The license manager could not be started.
An incorrect port number was used on the SERVER line(s) in the ansyslmd.ini file or in the setting
of the licensing path environment variable ANSYSLMD_LICENSE_FILE
If none of the above causes are applicable, the Licensing Interconnect may not have started because
it was not able to start the FlexNet server or may have exited after failing to restart the FlexNet
server. Check the FlexNet license log file (license.log). If you see the following lines multiple
times, try rebooting your license server machine:
(lmgrd) ansyslmd exited with status 28 (Communications error)
(lmgrd) Since this is an unknown status, license server
(lmgrd) manager (lmgrd) will attempt to re-start the vendor daemon.
(lmgrd) REStarted ansyslmd (pid 103864)
There is a typographical error in the license file's SERVER line. Typically, the machine ID was mistyped
when manually entering the license file on a machine.
You tried to install another machine's license file on a machine and changed the SERVER line in the
file to have this machine's hostname but not the machine ID.
A laptop with a docking station (with an Ethernet card in it) is removed from the docking station
and the license file was made using this card's Ethernet address.
The feature was removed during lmreread but the client is reading an old copy of the license file
that still contains the removed feature.
This message will appear if the date on the client machine has changed. The date should never be
set ahead or behind the actual date.
This message can be generated if the feature has expired (on the server), or has not yet started, or
the version is greater than the highest supported version, or the license file has been edited while
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
90 of ANSYS, Inc. and its subsidiaries and affiliates.
Licensing Error Messages
the license server is running and the license file is not reread. Additional causes for this message
include:
If you are trying to install another machine's license file on a machine AND changes both the host-
name and the machine ID information on the SERVER line to be this machine's information. The
INCREMENT lines contained in the license file are still invalid for this machine.
If new information for the requested feature was added to the license file but neither an lmreread
was issued nor was the license manager restarted.
If a laptop with a docking station (with an Ethernet card in it) is removed from the docking station,
and the license was made using this card's Ethernet address, AND the user edited the SERVER line,
replacing the Ethernet address with the disk signature of the machine (in an attempt to fix the
problem). Such an attempt will not succeed because the INCREMENT lines were created using the
docking station's Ethernet address, which in this situation can no longer be seen on this machine.
If one or more INCREMENT lines that were made for machine A were installed in machine B's license
file and those features were trying to be checked out from machine B.
Your license has expired; contact your ANSYS sales representative for a renewal.
A license does not exist for the requested product. Verify that the ANSYSLMD_LICENSE_FILE environment
variable and the ansyslmd.ini file are pointing to the correct license server.
Verify that you are running the correct product. Use the Set License Preferences for User option of
the ANSLIC_ADMIN utility to specify the products and the product order you want to use.
If you are not licensed to run this product, contact your ANSYS sales representative to obtain a license.
If you are licensed to run this product, install the license from the license supplied by ANSYS, Inc. or your
ANSYS sales representative using the ANSLIC_ADMIN utility. If you have already created the license,
use the ANSYS License Management Center to reread the license file.
You could also see this message if you are trying to use a license manager daemon from a previous release.
For the current version of FlexNet, see Compatibility with Other FlexNet-Licensed Software (p. 1).
You may see this message if you specify a particular license (such as with the -p command line
option on the Mechanical APDL (ANSYS) product) and no license for that product is currently
available in the license path. Check the following:
The license is not included in your license preferences as set with the Specify License Preferences for
User in the ANSLIC_ADMIN utility.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 91
Troubleshooting
Your Technology Enhancements and Customer Support (TECS) for this version may have expired.
The build date in the program is newer than the version in the license file. You may not be authorized
to run a new release or you may not have installed your new license. If this is the case, install the
license using the ANSYS License Management Center. If you have installed the new license, use
the ANSYS License Management Center to reread the license file. To view the build date in
Mechanical APDL (ANSYS), use the -v command line option.
For the current version of FlexNet, see Compatibility with Other FlexNet-Licensed Software (p. 1).
Verify that you are not using the license manager daemons supplied with a previous release.
This error can also occur if the license key contains incorrect characters or format (sometimes caused
by transferring the file).
Invalid license file: None of the hostnames in the license file match the system hostname.
This message occurs when you install the license file if the hostname of the system you are running
on does not match any of the hostnames in your license file. Some possible reasons why this can
happen include:
You are attempting to run on a system that has not been included in your license.
The hostname of the system you are working on has been changed since it was used to generate the
license information.
A typographical error was introduced when the hostname was entered when creating the license key.
On some newer Linux machines, the system hostname is not listed consistently in the /etc/hosts
file. When you run the Get System Hostid Information option of the ANSYS License Management
Center, the utility uses the localhost information instead of the correct system hostname. An example
of the problematic /etc/hosts file might look like this:
# Do not remove the following line, or various programs
# that require network functionality will fail.
127.0.0.1 localhost.localdomain localhost abclinux5
10.99.9.99 abclinux5 abclinux5
[root@abclinux5 ~]$ hostname
abclinux5
[root@abclinux5 ~]$ hostname -s
localhost
[root@abclinux5 ~]$
In this example, the Get System Hostid Information option would incorrectly use the localhost
information.
To correct the problem, you need to edit the /etc/hosts file and change the order of the
hostname lines. The example shown above would then look like this:
# Do not remove the following line, or various programs
# that require network functionality will fail.
10.99.9.99 abclinux5 abclinux5
127.0.0.1 localhost.localdomain localhost abclinux5
[root@abclinux5 ~]$ hostname
abclinux5
[root@abclinux5 ~]$ hostname -s
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
92 of ANSYS, Inc. and its subsidiaries and affiliates.
Licensing Error Messages
abclinux5
[root@abclinux5 ~]$
In the corrected example, the Get System Hostid Information option would correctly use the
abclinux5 hostname.
View the license debug log files (FlexNet license.log and the Licensing Interconnect an-
sysli_server.log) to find the specific cause of this message.
This message will appear if one or more of the SERVER computer names do not appear in the client
computer's /etc/hosts file (Linux) or the services file (Windows).
***The ANSYS license manager server is down. Unless a connection is reestablished, ANSYS will
exit in nn minutes.
A message similar to this one occurs in a one-server license environment if your license manager
has quit running. In a three-license server environment, the ANSYS, Inc. license manager must be
running on at least two of the three license server machines at all times. If two of the license server
machines go down, or two of the machines are not running the license manager, this error message
will appear in the program output or in a message box. The program will continue to run for nn
minutes to allow the license manager to be restarted or to be started on a second machine if using
redundant servers. When this error message appears, start the license manager on the other machines
designated as license servers.
If you get this message and determine that the license manager is still running, and you are running
in a one-server environment, then the IP address of the license server machine was changed while
the ANSYS product was running (this is usually caused by connecting to or disconnecting from an
Internet Service Provider (ISP) that dynamically allocates IP addresses). To correct this situation, you
must return the IP address to the same address that the license server had when the ANSYS product
was started.
If the IP address changes after you start the ANSYS product (either because you connected to or
disconnected from your ISP), you can correct the error by restarting the ANSYS product. You should
not need to restart the license manager.
You can avoid this problem by remaining connected to or disconnected from the ISP the entire
time you are running the application.
For the current version of FlexNet, see Compatibility with Other FlexNet-Licensed Software (p. 1).
Verify that you are not using the license manager daemons supplied with a previous release.
Your version of the ANSYS license client software is out of date. Refer to Licensing Error Messages
in the Troubleshooting section of the ANSYS, Inc. Licensing Guide.
The version of the license client ansysli_client [version] must be greater or equal to the
client ANSYS application [version].
This message indicates that you are attempting to start an ANSYS, Inc. application with an out-of-
date version of the license client.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 93
Troubleshooting
If you are using different installation directories for the current and prior versions, you need to ensure
that each version is running from the appropriate installation directory.
If you are using the same installation directory for the current version as you used for the prior
version, try the following solutions:
The license client was running during the installation process and was not replaced. In this case, close
all ANSYS, Inc. applications, making sure that the license client closes, and then run the Complete Un-
finished Licensing Installation Configuration option from the Client ANSLIC_ADMINs Tools menu.
The license client was running during the installation process and was replaced, but the application is
not reading the new client. In this case, close all ANSYS, Inc. applications, making sure that the license
client closes, and restart the ANSYS, Inc. application.
Your version of the ANSYS license manager software is out of date. Download and install the
current ANSYS license manager from the ANSYS Customer Portal.
The version of the license server ansysli_server [version] must be greater or equal to the
client ANSYS application [version].
This message indicates that you are attempting to start an ANSYS, Inc. product with an out-of-date
version of the license server. You need to update to the latest version of the license manager.
The server and the client are having difficulties communicating. This error is usually caused by the
network setup or by the network data being different from the data in the license file (for example,
the server name, machine ID, port number, or vendor daemon).
Confirm that the information on the SERVER line of the license file is the correct information for the
server.
Confirm that the syntax of the SERVER and VENDOR lines of the license file is correct.
Check that the hosts file on the client machine contains the license server.
***The license server is taking too long to respond. The application has stopped waiting for a
reply. The license server may be experiencing a high demand or a temporary outage. Try again
later.
In rare occasions, your site could be submitting too many requests too quickly (simultaneously or
nearly simultaneously) to the ANSYS, Inc. License Manager. In this case, you will also see that the
license server machine in question is averaging 85% CPU usage or higher. In this scenario, we re-
commend that you either point some of the clients to a different license server or install one or
more standalone licensing interconnects for some of the clients to use. For instructions on installing
a standalone licensing interconnect, see Run the ANSYS Licensing Interconnect without
FlexNet (p. 19).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
94 of ANSYS, Inc. and its subsidiaries and affiliates.
License Manager Installation Directory Errors
If you see the above message and the server is not experiencing any demand, a virus scanner may
be blocking connections to your license server. Rebooting your license server may also resolve the
issue.
If you see the above message in your licensing log file, your operating system was not able to free
a port before the timeout period expired. This situation could happen if the port is being used by
some other application, or after you shut down a server if you did not wait long enough for the
ports to free before restarting it. This situation appears to occur more frequently on Sun systems,
because these operating systems have a default timeout period to free a port that may not be suf-
ficient.
On Sun systems, the default is 4 minutes for the CLOSE_WAIT and TIME_WAIT port states. You can
adjust the default timeout period to 30 seconds by issuing either of the following commands as
appropriate for your operating system level:
ndd /dev/tcp -set tcp_time_wait_interval 30000
ndd /dev/tcp -set tcp_close_wait_interval 30000
Consult your system administrator before making changes to your default operating system settings
or to determine which command is appropriate for your operating system level.
***Failed to retrieve license preferences. Be sure that you are able to connect to the license
server.
If you attempt to set your license preferences and the client information is at a higher release than
the server information, you may see this message. To verify, see the getuserprefs.log file (on
Linux machines, in .ansys in your home directory; on Windows, in %TEMP%\.ansys). Note the
last lines in the example below:
2012/08/24 17:18:00 INFO Not connected to a local port.
2012/08/24 17:18:00 NEW_CONNECTION
Connected to license server: 2325@linux10.ansys.com.
ANSYSLI_SERVERS: 2325@linux10.ansys.com
Servers: 1055@linux10.ansys.com
2012/08/24 17:18:01 SITE_PREFS 2012.0806
Your version of the ANSYS license manager software is out
of date. Please download and install the current ANSYS license
manager from the ANSYS Customer Portal.
The version of the license server 2325@linux10.ansys.com [1.1.2]
must be greater or equal to the client ALI_UTIL version [1.3.0].
***License File filename has changed. Please do a reread to update the server.
The license file or the FlexNet options file has been changed since the last restart of the license
manager or reread of the license file. The changes will not be available until you restart the license
manager or reread the license file. If you are running the ANSYS Licensing Interconnect and FlexNet
independently and have cached the license file, the cached license file may be out of date. Restart
FlexNet or reread the license file to update the cached license file. If you make changes to the license
file, in addition to rereading the license file in FlexNet, you must also recache the license file in the
Licensing Interconnect by restarting the Licensing Interconnect or by using the Reread License
Manager Settings option in the ANSYS License Management Center.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 95
Troubleshooting
If you see this message or one that is similar, you may need to correct the path to the license
manager. The message will display a particular error code (listed below). The -100 series numbers
indicate errors associated with the path you entered; the -200 series numbers indicate errors asso-
ciated with the path specified in the service.
-108 / -208: path is a UNC path; UNC paths are not permitted.
-109 / -209: path contains a remote (network) drive; remote drives are not permitted.
-110 / -210: path does not contain a valid drive letter from a to z.
-114 / -214: root path is invalid. (Example: The drive specified in the path doesnt exist.)
-115 / -215: paths root path isnt a local fixed-media drive path.
-116 / -216: path contains either a symbolic link or a junction, neither of which is permitted.
-117 / -217: path is a short (8.3) file name format path, which is not permitted.
If you see the above message when attempting to return a borrowed license before the expiration
date, the -2 -p license manager startup option might have been set. The -2 -p option is not
supported. If you are running an earlier release, you must manually unset the option. In this case,
you may also see the following in the log file:
You may also see the above message if the existing server specification does not contain the machine
from which the license was borrowed. To correct the problem, add the machine to the server spe-
cification. If the ANSYS Borrow Utility is open when the server specification is changed to contain
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
96 of ANSYS, Inc. and its subsidiaries and affiliates.
FlexNet License Log File Errors
this server, you must close and restart the utility after changing the license server specification and
before returning the borrowed license.
The hostname in the SERVER line of the license file does not match the hostname of the system. In
this case, change the hostname in the license file. Other possible causes include:
The license file was put on a machine other than the one for which it was created; therefore, the
hostname is not correct.
The hostname of the license server changed. Change the hostname on the SERVER line of the license
file to correct this problem. REMEMBER to send ANSYS the new hostname so that future license
files are made with the correct hostname.
The license file was put on a machine other than the one for which it was created AND the user
changed the machine's ID on the SERVER line but did not change the hostname. If the machine ID
is also wrong, you will also see a message about the wrong hostid on SERVER line after correcting
the hostname.
The wrong hostname was used to create the license file. As long as the correct machine ID was
used, you should be able to change the hostname on the SERVER line of the license file to fix this
problem. REMEMBER to send ANSYS the correct hostname so that future license files are made with
the correct hostname.
The INCREMENT lines in the license file are not valid for this system (Hostid mismatch). This error
will also occur if the license file was typed incorrectly. Additional causes for this message include:
If a license file created for machine A is being installed on machine B AND the user changed the
hostname and the machine ID to machine B's in the SERVER line.
If INCREMENT lines created for machine A are appended to an existing ansyslmd.lic file on
machine B.
If a laptop with a docking station (with an Ethernet card in it) is removed from the docking station,
and the license was made using this card's Ethernet address, AND the user edited the SERVER line,
replacing the Ethernet address with the disk signature of the machine (in an attempt to fix the
problem). Such an attempt will not succeed because the INCREMENT lines were created using the
docking station's Ethernet address, which in this situation can no longer be seen on this machine.
In a three-server license environment, if the license file was created using an incorrect hostid for
one of the license servers, this message will appear and will prohibit an ANSYS product from running
on any machine. Verify that the hostid in the license file matches the hostid on all three license
servers. If it does not, the license file must be created using the correct hostid for all license server
machines.
***Wrong Hostid on SERVER line for license file: <path to license file>
License file is not valid for this machine. Possible causes include:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 97
Troubleshooting
There is a typographical error. If the license file was entered manually, the machine ID may have
been incorrectly typed in the SERVER line.
The user installed a license file created for machine A on machine B and changed the hostname in
the SERVER line but did not change the machine ID.
The hostid changed on a machine but the hostname stayed the same.
A laptop with a docking station (with an Ethernet card in it) is removed from the docking station,
and the license file was made using this card's Ethernet address.
A license file was made using the Windows disk signature but the keyword 'DISK_SERIAL_NUM='
was not put before the ID. Ethernet address would be expected.
*** XXX : Not a valid server hostname, exiting. Valid server hosts are: YYY.
The hostname listed in the ansyslmd.lic (YYY) file does not match the hostname of the system
(XXX).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
98 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 8: Product Variable Table
The following table shows each ANSYS, Inc. product and its associated feature name as used in the IN-
CREMENT lines.
This table is provided as a reference for both current and legacy products. Not all products listed are
generally available but are included here for customers running an older release. Contact your ANSYS
sales representative or technical support representative for details regarding product availability.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 99
Product Variable Table
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
100 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Feature Names
ANSYS HPC anshpc
ANSYS HPC Pack anshpc_pack
ANSYS HPC Parametric Pack ans_dp_pack
ANSYS LS-DYNA Parallel dysmp
ANSYS Pre/Post Processing and Geometry Interface Products
ANSYS Autodyn PrepPost acdi_adprepost
ANSYS CATIA V6 Reader a_catv6_reader
ANSYS CFD-Post acfx_post
ANSYS CFD PrepPost acfd_preppost
ANSYS Composite PrepPost acpreppost
ANSYS DesignModeler agppi
ANSYS Extended Meshing amesh_extended
ANSYS Geometry Interfaces a_geometry
ANSYS ICEM CFD Hexa aimed, aihexa, aimshcrt, aibfcart, aiiges,
aiacis, aioutput, aioutcfd, aidxf, aiquad,
aimshcrt
ANSYS ICEM CFD Tetra/Prism aimed, aitetra, aiprism, aiiges, aiacis,
aioutput, aioutcfd, aidxf, aiquad
ANSYS Interface for Team Center Engineering pdmiman
ANSYS JT Reader a_jt_reader
ANSYS LS-DYNA PrepPost dynapp*
ANSYS Mechanical PrepPost preppost*
ANSYS Meshing amesh
ANSYS Mesh Morpher paramesh
ANSYS RBF Morph Module rbfmorph
ANSYS SpaceClaim CATIA V5 Interface a_spaceclaim_catv5
ANSYS SpaceClaim Direct Modeler a_spaceclaim_dirmod
GD&T Module for SpaceClaim a_spaceclaim_gdt
JT Open Reader for SpaceClaim a_spaceclaim_jt
Faceted Data Toolkit for SpaceClaim a_spaceclaim_faceteddata
3D PDF Reader for SpaceClaim a_spaceclaim_3dpdf
CADNexus/CAPRI CAE Gateway for CATIA V5 capricatv5
Geometry Interface for Autodesk piautoin
Geometry Interface for CATIA V5 picatv5
Geometry Interface for CATIA V5 Linux linux_catiav5
Geometry Interface for Creo Elements/Direct 1spacdes
Modeling
Geometry Interface for Creo Parametric piproe
Geometry Interface for NX piug
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 101
Product Variable Table
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
102 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Feature Names
ANSYS ASAS FEMGV acdi_femgv, acdi_fgv_asas
ANSYS ASAS-OFFSHORE acdi_asas, acdi_asaslink, acdi_asasnl,
acdi_asas-vis, acdi_beamst, acdi_comped,
acdi_fatjack, acdi_loco, acdi_mass,
acdi_maxmin, acdi_post, acdi_postnl,
acdi_prebeam, acdi_prenl, acdi_response,
acdi_splinter, acdi_wave, acdi_windspec,
acdi_xtract, preppost
ANSYS BEAMCHECK acdi_asas-vis, acdi_beamst
ANSYS FATJACK acdi_fatjack
ANSYS Electronic Thermal Management Products
ANSYS Iceopt aice_opt
ANSYS Icepak aice_pak, aiiges, aice_mesher, aice_solv
ANSYS Legacy Products
ANSYS ASAS acdi_asas, acdi_asaslink, acdi_asasnl,
acdi_asas-vis, acdi_beamst, acdi_comped,
acdi_loco, acdi_maxmin, acdi_post,
acdi_postnl, acdi_prebeam, acdi_prenl,
acdi_response, acdi_xtract, preppost
ANSYS Autodyn HPC acdi_adhpc
ANSYS CAE Templates caetmpl
ANSYS CFD HPC acfd_par_proc
ANSYS CFX-CAD2Mesh with DesignModeler cad2mesh, aimed, aioutput, aiprism, aitetra,
agppi, aiiges, aiacis, aipips, aidxf, acfx_pre
ANSYS CFX-Flo acfx_anymodule
ANSYS CFX Full Capability Solver acfx_pre, acfx_solver acfx_nolimit, acfx_mfr,
acfx_multiphase, acfx_combustion,
acfx_radiation, acfx_parallel,
acfx_advanced_turbulence,
acfx_turbulence_transition
ANSYS CFX-Mesh cad2mesh
ANSYS CFX Parallel Computing acfx_par_proc
ANSYS CFX PrepPost acfx_anymodule
ANSYS DesignSpace Structural dsstruct
ANSYS Emag emag*
ANSYS ICEM CFD aienv, aienvsub, aiprism, aiiges, aiacis,
aiedgeom, aioutcfd, aidxf
ANSYS ICEM CFD AddOn aiaddon
ANSYS ICEM CFD Hexa CAA V5 Based (for aihexct5, aihexct5e
CATIA V5)
ANSYS ICEM CFD Quad aimed, aiquad
ANSYS ICEM CFD Visual3 / PV3 aivis3
ANSYS Mechanical HPC mechhpc
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 103
Product Variable Table
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
104 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Feature Names
maxwlspc, schem_gui, m2dfs_th,
m2dfs_tran, m2dfs_qs_solve,
m3dfs_qs_solve
ANSYS Maxwell 3D Pre/Post Processor m2dfs_gui, m3dfs_gui, maxwell_desktop
ANSYS Maxwell 3D QS m2dfs_gui, m3dfs_gui, maxwell_desktop,
m2dfs_qs_solve, m3dfs_qs_solve
ANSYS Optimetrics (For HFSS, Q3D Extractor, optimetrics, ansoft_distrib_engine
Maxwell)
ANSYS PExprt m2dfs_gui, maxwell_desktop, maxwlspc,
pemag, pexprt, m2dfs_qs_solve
ANSYS Q3D Extractor q3d_desktop, si2d_gui, si2d_solve, si3d_gui,
si3d_solve
ANSYS Q3D Extractor 3D Solver si3d_solve
ANSYS Q3D Extractor Pre/Post Processor q3d_desktop, si2d_gui, si3d_gui
ANSYS RF Option ensemble_25_sim, symphony_dt_sim,
symphony_fd_sim, nexxim_dc, nexxim_tran,
nexxim_hb, nexxim_osc, nexxim_tvnoise,
filter_synthesis
ANSYS RMxprt maxwell_desktop, rmxprt_bcm, rmxprt_ecm,
rmxprt_gui, rmxprt_im, rmxprt_sym
ANSYS RMxprt (Node) maxwell_desktop, rmxprt_bcm, rmxprt_ecm,
rmxprt_gui, rmxprt_im, rmxprt_sym
ANSYS SI Option nexxim_dc, nexxim_eye, nexxim_tran,
nexxim_ami, hfss_transient_solve,
designer_hspice
ANSYS Simplorer simplorer_desktop, simplorer_gui,
simplorer_sim, mspc_fws, DayBasic,
DayIEEEDataInterface, SimplorerBasic,
SimplorerKernel, SimplorerSchematic,
SimplorerLibPower, SimplorerLibMechanics,
SimplorerLibAutomotive,
SimplorerLibHydraulic, SimplorerLibSensor
ANSYS Simplorer Advanced simplorer_advanced,
simplorer_CProgrInterface,
simplorer_desktop, simplorer_gui,
simplorer_sim, mspc_fws, DayBasic,
DayIEEEDataInterface, SimplorerBasic.
SimplorerCProgrInterface,
SimplorerFrequencyStepResp,
SimplorerKernel, SimplorerMaxwellTr2D,
SimplorerOptimizer, SimplorerSchematic,
SimplorerSIMULINK, SimplorerLibPower,
SimplorerLibMechanics,
SimplorerLibAutomotive,
SimplorerLibHydraulic, SimplorerLibSensor,
simplorer_vhdlams, simplorer_control
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 105
Product Variable Table
An * after a feature name indicates that an item is a product variable and can be used on a stand-alone
basis to start a product run in the Mechanical APDL (ANSYS) application.
Products listed here use the ANSYS license manager (ansyslmd vendor daemon). ANSYS, Inc. does
supply licenses for products that use other license managers, such as the Fluent product which is not
listed above; however, those products will use their respective license managers. To determine the license
manager to which the license applies, see Recognizing an ANSYS, Inc. License File (p. 7)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
106 of ANSYS, Inc. and its subsidiaries and affiliates.
Glossary
ANSLIC_ADMIN A utility that centralizes the various ANSYS product licensing administrat-
ive functions.
ANSWAIT An environment variable that will allow you to queue your ANSYS job in
the event that all ANSYS licenses are in use. Once a license becomes
available and you are next on the queue, your ANSYS job will automatic-
ally start.
ANSYS, Inc. License Man- The ANSYS, Inc. License Manager consists of three components. The first
ager two are FlexNet components; the last one is an ANSYS component. See
the definitions of each for more information.
lmgrd
ansyslmd
ansysli_server
ANSYS License Manage- The ANSYS License Management Center is a browser-based user inter-
ment Center face that centralizes many of the ANSYS licensing administrative functions.
ansysli_monitor The ansysli_monitor runs on the same machine where the an-
sysli_server is running and ensures that the Licensing Interconnect
is functioning correctly. If the Licensing Interconnect is not running,
ansysli_monitor can restart it. If the Licensing Interconnect is running
but is not responsive, ansysli_monitor can kill and restart it.
ansysli port number Communication channel by which the ANSYS, Inc. applications commu-
nicate with the Licensing Interconnect. The default ansysli port number
is 2325.
ANSYSLMD_LICENSE_FILE An environment variable that may be used to specify the license server
machine from which you want to check out a license.
ansyslmd This is one of the FlexNet components of the ANSYS, Inc. license manager
used to process ANSYS product licensing requests, including issuing and
returning licenses. ansyslmd, often referred to as the vendor daemon,
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 107
Glossary
backup server In a three-server (redundant triad) network, the two servers not chosen
to be the master are the backup servers. If the master server goes down,
the backup server listed next in the license file automatically assumes
the role of master. (A backup server is also known as a shadow server.)
borrowable license A borrowable license is a license that you can use temporarily outside
of the company facility (such as at home on a laptop). A special license
key is required before any license can be borrowed.
build date The build date is the year, month, and date the ANSYS application was
built. The version field in the license file specifies the latest build date
that can be run using that license. It may also appear as 9999.9999 if a
maintenance agreement is not applicable.
Capability ANSYS, Inc. has assigned identifiers to each of the specific areas of func-
tionality in the software. We refer to these identifiers as capabilities, which
you may see in ANSYS, Inc. licensing displays and logs. Each capability
can be satisfied by at least one license feature; often, multiple license
features can satisfy a particular capability.
client A client is a machine that requests licenses but is not a license server
machine (i.e., does not have licenses installed on it).
feature The word feature, when used in the descriptions of the licensing utilities,
refers to the ANSYS product. See Product Variable Table (p. 99) for the
list of ANSYS products and their corresponding license features.
FlexNet A component of the ANSYS, Inc. license manager used for all ANSYS
products. Also called FlexNet License Manager. The FlexNet component
authenticates and processes all license requests.
FlexNet license log file Typically referred to as the FlexNet Debug Log File, it contains information
relevant to licensing activity. This file provides a way of tracking licensing
problems that may occur. The licensing log file, license.log, is located
in the licensing directory by default.
FlexNet port number Communication channel by which the license manager communicates
with the client (Licensing Interconnect). The default FlexNet port number
is 1055.
floating license Anyone on the network can run a licensed ANSYS product, up to the
limit specified in the license file. Floating licenses require the license
manager daemon (lmgrd) and the vendor daemon (ansyslmd) to be
running to count the concurrent usage of the licenses.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
108 of ANSYS, Inc. and its subsidiaries and affiliates.
license borrowing License borrowing allows a user to take a license for use outside of the
company facility, such as for an engineer to take a license home on his
laptop.
license file A license file grants access to run specified products. Each licensed
product will have an entry in the license file, ansyslmd.lic, which
will reside in the license_files directory. Proper installation of a license
file grants access to ANSYS products. Install the license file using the
ANSYS License Management Center or during the installation process.
license.log Typically referred to as the FlexNet Debug Log File, it contains information
relevant to licensing activity. This file provides a way of tracking licensing
problems that may occur. The licensing log file is located in the licensing
directory by default.
license manager Software used for licensing ANSYS, Inc. products. The ANSYS, Inc. License
Manager is comprised of two components: the FlexNet software and the
Licensing Interconnect.
license options file A FlexNet file containing license manager-related resource information.
By default, the file is named ansyslmd.opt and resides in the li-
cense_files directory. You may specify the following information in the
options file:
license server machine A license server machine is a computer that you have designated to be
the administrator of ANSYS product licenses; the licenses are installed
on the server machine(s). One or three systems (redundant triad) can be
used to administer any particular set of ANSYS product licenses.
license task Each concurrent use of an ANSYS product is a license task. Each use of
an ANSYS product will take a number of license tasks from the total
number available.
licensing directory The default location for the licensing files. On Linux systems, the licensing
directory is /ansys_inc/shared_files/licensing. On Windows
systems, the default licensing directory is <OS_Drive>\Program
Files\ANSYS Inc\Shared Files\Licensing, located in the
same drive as the operating system.
Licensing Interconnect Communications between the ANSYS applications, lmgrd, and an-
syslmd are handled by an intermediary process called the ANSYS Licens-
ing Interconnect. The ANSYS Licensing Interconnect communicates with
the FlexNet license manager to authenticate and process all license re-
quests.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 109
Glossary
Licensing Interconnect Log Provides a chronicle of Licensing Interconnect licensing activity, including
File problems. The Licensing Interconnect log file, ansysli_server.log,
is located in the licensing directory by default.
lmadmin A group of users that you designate to have the ability to perform license
administrative tasks that are considered disruptive.
lmgrd One of the FlexNet components of the ANSYS, Inc. License Manager, used
to process ANSYS product licensing requests, including issuing and re-
turning licenses.
LMTOOLS LMTOOLS is a Windows-only utility that will perform various license ad-
ministrator functions, such as listing the users of licensed products.
LMTOOLS is no longer sufficient to manage the ANSYS, Inc. License
Manager and the Licensing Interconnect. You should use the ANSYS Li-
cense Management Center to start or stop the license manager and
use the ANSLIC_ADMIN utility to check the license status, etc. However,
if you have well-established processes to manage FlexNet, you can con-
tinue to use LMTOOLS (see Advanced Licensing Configuration Options).
master server In a three-server (redundant triad) network, one of the servers must be
the master server. The server listed first in the license file automatically
assumes the role of master. The other two license servers machines are
shadow servers (or backup servers). In a one-server network, that server
is automatically the master.
path When used in the context of a license file path, the list of places that are
searched in order to locate a valid license file. The path is built from
values in the ANSYSLMD_LICENSE_FILE environment variable, settings
in the ansyslmd.ini file, or an actual license file.
product variable Each ANSYS product has been assigned a specific product variable value.
Use this product variable value when starting a job to specify which
ANSYS product is to be run. For Mechanical APDL, the product variable
may be set by using the -p command line option, the AN-
SYS162_PRODUCT environment variable, or the Mechanical APDL
launcher. See Product Variable Table (p. 99) for a list of ANSYS products
and their associated product variables/feature names.
quorum You may designate either one or three machines to be license servers.
In a three-server (redundant triad) network, license manager daemons
must be running on the majority (2) of the server machines (a quorum)
before requests for licenses will be processed.
redundant (triad) servers Having multiple machines designated as license servers for an ANSYS
product. Redundancy can be achieved either by having three license
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
110 of ANSYS, Inc. and its subsidiaries and affiliates.
server machines working together in tandem, where two of the three
must be running at all times but serving from a single set of licenses, or
by having any number of license server machines running independently,
each serving from different license files.
Tamper Resistant License A sixty character encryption used in the licensing file.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 111
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
112 of ANSYS, Inc. and its subsidiaries and affiliates.
definition, 107
Index ansysli_monitor
definition, 107
Symbols ansysli_server, 3
definition, 107
ansysli_server log file
A definition, 107
Academic licenses, 48, 62
ANSYSLI_SERVERS, 47
Agreement number, 69
ANSYSLI_TIMEOUT_CONNECT, 47
All licenses reserved, 89
ANSYSLI_TIMEOUT_TCP, 47
ANS_FLEXLM_DISABLE_DEFLICPATH, 47
ansyslmd, 2-5
ANSLIC_ADMIN utility, 57
definition, 107
debug log, 37
ansyslmd.ini
definition, 107
definition, 108
display customer number, 69
ansyslmd.ini file, 24, 48, 59
display queued licenses, 68
ansyslmd.lic file, 2-3, 24, 32, 48
display the license status, 68
ansyslmd.opt file, 26, 61
gather diagnostic information, 39, 69
ANSYSLMD_LICENSE_FILE, 3, 47
modify startup options, 66
ANSYSLMD_LICENSE_FILE environment variable
run the ANSYS borrow utility, 63
definition, 107
set license preferences, 62
set site preferences, 65
specify product order, 65
B
specifying the license server, 59 Backup server
using its options (Linux), 57 definition, 108
view FlexNet debug log file, 69 boot_ansflex file, 20
View status/diagnostic options, 68 Borrowable license
view the ansysli debug log file, 69 definition, 108
ANSWAIT environment variable, 54 Borrowing
definition, 107 licenses, 55, 63
ANSYS Build date
licenses, 8 definition, 108
ANSYS License Management Center, 32
display license server hostid, 36 C
functionality, 32 Caching FlexNet licenses, 19, 66
install license, 32 Caching license servers, 67
License Manager run mode, 39 Capability
log, 38 definition, 108
requirements, 31, 71 Changing Java Version, 44
rereading license manager settings, 35 Client configuration, 47
shutdown the license manager, 34 Clients
start the license manager, 34 definition, 108
update license, 32 Commands (Linux)
using its options , 32 ps, 20, 22
ANSYS Licensing Guide Commercial licenses, 48, 62
viewing, 40 Communications requirements, 12
ansys_pid utility, 78 Complete unfinished client licensing installation config-
ansysli, 2 uration, 57
definition, 107 Configuring redundant (triad) servers, 27
port number, 13 Configuring TCP/IP, 12
ansysli port number Configuring the license server machine, 24
definition, 107 .cshrc file, 59
ansysli_client customer number, 69
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 113
Index
D license (ansyslmd.lic), 24
daemon license files format, 3
vendor, 4-5 license.log, 20, 22
Daemons viewing, 37-38, 69
starting at system boot time, 20, 22 sample license files, 6
starting manually, 34 Firewall settings, 27
vendor (ansyslmd), 3 FlexNet
Debugging, 77 compatibility with other software, 1
design points definition, 108
licensing, 54 license, 36
Diagnostic information port number, 13
gathering, 69 FlexNet debug log (license.log)
Diagnostic log files, 39 viewing, 37
Display customer number, 69 FlexNet debug log file (license.log)
Display license server hostid, 36 viewing, 38, 69
Display license status, 68 FlexNet icensing Guide
Display queued licenses, 68 viewing, 40
Dongles FlexNet license options file (ansyslmd.opt)
using, 71 editing, 26
FlexNet Licenses
E viewing, 36
FLEXNet Manager, 19, 57
Enabling Secure Connections, 41
FlexNet Manager, 31
Environment variables
FlexNet port number
ANS_FLEXLM_DISABLE_DEFLICPATH, 47
definition, 108
ANSWAIT, 54
floating license
ANSYSLI_SERVERS, 47
definition, 108
ANSYSLI_TIMEOUT_CONNECT, 47
Floating licenses, 1, 8
ANSYSLI_TIMEOUT_TCP, 47
Format of license files, 3
ANSYSLMD_LICENSE_FILE, 3, 47
Freeing a license, 57
Error messages, 77
Functions requiring lmadmin group privileges, 25
launcher , 88
license borrowing, 96
license log file, 97 G
licensing, 20, 89 Gather diagnostic information, 69
Establishing user licensing preferences, 48 Group
Expired license, 91 creating, 25
Group restrictions
F defining, 25
Feature
definition, 108 H
Feature names, 99 high performance computing
Files licensing, 51
ansyslmd.ini, 24, 48, 59 hostid, 4, 8
ansyslmd.lic, 32, 48 hostname, 4, 8
ansyslmd.opt, 26, 61 HPC licensing, 51
boot_ansflex HPC Parametric Pack licensing, 54
init_ansysli, 20 HTTPS
.cshrc, 59 configuring, 41
init_ansysli, 20
init_ansyslm_tomcat, 22 I
license, 2-3 INCREMENT lines, 5, 99
installing, 24 init_ansysli, 20
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
114 of ANSYS, Inc. and its subsidiaries and affiliates.
init_ansyslm_tomcat, 22 error messages, 97
Installation License log file error messages, 97
license, 32 License Management Center, 31, 59
uninstalling the license manager, 28 launching, 59
Installing license files, 24 License manager
Installing the license manager, 11 advanced configuration, 19
Linux, 16 compatibility with other software, 1
post-installation instructions, 20 Complete unfinished licensing client installation
Windows, 14 configuration, 57
installing the license manager, 13 Complete unfinished licensing installation configur-
Complete unfinished client licensing installation ation, 32
configuration, 57 components, 2
Interconnect daemon, 110
debug log , 37 defined, 1
Interconnect debug log (license.log) definition, 109
viewing, 37 installation prerequisites, 14
is down error message, 89 installing, 11, 13
installing on Linux, 16
J installing on Windows, 14
Java modifying startup command options, 24
version, 44 modifying startup options, 66
post-installation instructions, 20
L shutting down, 34
Launcher shutting down with ANSLIC_ADMIN, 34
error messages, 88 starting at system boot time, 20
License starting manually, 34
error message: has expired, 91 starting with ANSYS License Management Center,
installing, 32 34
updating, 32 uninstalling, 28
License administration, 31, 57 License Manager
creating lmadmin group, 57 rereading settings, 35
License borrowing, 55, 63 License Manager Run Mode, 39
definition, 109 License methods
running, 55 sharing vs. separate, 62
running the borrow utility, 63 License options file (ansyslmd.opt)
setup, 63 definition, 109
License borrowing error messages, 96 License preferences
License file installation, 24 academic vs. commercial, 48, 62
License files, 2-3 License queuing, 54, 57
definition, 109 License server
example, 6 error message: is down, 89
format, 3 specifying, 26
INCREMENT lines, 5 license server machines, 2
recognizing, 7 License server machines
SERVER lines, 4 definition, 7, 109
settings precedence, 48 display hostid, 36
specifying the location, 24 master, 7
VENDOR lines, 4 selecting, 8
License key three-server network, 7
definition, 109 License server manager, 2
License log file (license.log) License servers
definition, 108-109 caching, 67
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 115
Index
configuring, 24 lmreread, 25
designating for license checkout, 57, 59 LMTOOLS, 19, 57
error messages, 20 lmutil
network licensing , 2 utility definition, 110
redundancy, 9 Log file, 110
shutting down the license manager daemon, 34 (see also license log file)
specifying, 59
License status M
display, 68 Master server, 7, 20, 22
License task definition, 110
definition, 109
license.log N
viewing, 37 Network File System
license.log file, 20, 22 licensing failures on, 24
viewing, 38, 69 Network licensing
Licenses network licensing considerations, 8
customer number, 69 queuing facility, 54
floating, 8 shutting down the license manager, 34
freeing, 57 starting license manager at system boot time, 20
installing/updating, 32 starting license manager manually, 34
waiting for available, 54 No license file found for feature error message, 91
Licensing No licenses are currently available error message, 89
debugging, 77
error messages, 77 P
problem situations, 79
Path
process, 1
definition, 110
sample scenario, 61
Pool of available tasks, 8
selecting server machines, 8
Port number
separate method, 62
FlexNet, 4
sharing method, 62
Port Number
tasks, 8
changing Tomcat port number, 23
three-server license network, 7
Port numbers
Licensing Configuration Details
changing, 13
viewing, 40
FlexNet, 13
Licensing directory, 1
Licensing Interconnect, 13
Licensing environment
Preferences
setting up, 31, 57
setting, 48, 62
Licensing error messages, 89
Product list, 99
Licensing Interconnect, 2
Product order
defining group restrictions, 25
specifying , 65
port number, 13
Product variable
running independently of FlexNet, 19
definition, 110
running without FlexNet, 19
PS command, 20, 22
Licensing Interconnect (ansysli_server), 3
Licensing preferences
establishing for users, 48
Q
Queued licenses
lmadmin group, 25, 57
display, 68
lmdown, 25
Queuing, 54, 57
lmgrd, 2
Quorum
utility definition, 110
definition, 110
lmhostid, 36
lmremove, 25
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
116 of ANSYS, Inc. and its subsidiaries and affiliates.
R licensing error messages, 89
Redundant (triad) servers problem situations, 79
setting up, 27 Troubleshooting ANSYS error messages, 77
Redundant server options, 9
Redundant servers U
definition, 110 Unavailable licenses, 89
Requirements Uninstalling the license manager, 28
ANSYS License Management Center, 31, 71 Updating license, 32
Reread License Manager Settings, 35 User privileges, 57
root login, 28, 57 Using the FlexNet options file, 26
Running the Licensing Interconnect and FlexNet inde- Using Dongles, 71
pendently, 19-20
Running the Licensing Interconnect without FlexNet, V
19 Vendor daemon, 2-3, 5
vendor daemon
S definition, 111
Sample license files, 6 Vendor daemon (ansyslmd), 4
Sample licensing scenario, 61 VENDOR lines, 4
SERVER lines, 4 View status/diagnostic options, 68
Set site preferences, 65 View the ansysli debug log file, 69
Shadow server Viewing FlexNet Licenses, 36
definition, 111 Viewing the FlexNet debug log, 37
Shutting down the license manager, 34 Viewing the FlexNet debug log file, 38, 69
Site preferences Viewing the interconnect debug log, 37
setting , 65
Specify product order, 65 W
Specifying firewall settings, 27 WANs, 8
Specifying the license server, 26, 59 Wide area networks, 8
Starting the license manager, 34
Starting the license manager at system boot time, 20
Startup options for license manager
modifying, 66
Status
viewing, 68
superuser login, 28, 57
Symbolic links, 1
T
Tasks, 8
TCP/IP
dial-up connection, 12
testing whether TCP/IP is installed, 12
TCP/IP requirements, 12
Three-server network, 7
Tomcat
changing port number, 23
starting at system boot time, 22
Troubleshooting
ansys_pid utility, 78
getting additional debugging information, 77
license borrowing errors, 96
license log file errors, 97
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 117
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
118 of ANSYS, Inc. and its subsidiaries and affiliates.
Installation Guide for Linux
The information in this guide applies to all ANSYS, Inc. products released on or after this date, until superseded
by a newer version of this guide. This guide replaces individual product installation guides from previous releases.
2015 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT, HFSS, AIM
and any and all ANSYS, Inc. brand, product, service and feature names, logos and slogans are registered trademarks
or trademarks of ANSYS, Inc. or its subsidiaries in the United States or other countries. ICEM CFD is a trademark
used by ANSYS, Inc. under license. CFX is a trademark of Sony Corporation in Japan. All other brand, product,
service and feature names or trademarks are the property of their respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
Linux Installation Guide
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
List of Tables
1.1. Supported Linux Platforms ..................................................................................................................... 2
1.2. CAD Support by Platform ........................................................................................................................ 3
2.1. Compiler Requirements for All Linux Versions ........................................................................................ 11
5.1. Startup Commands ............................................................................................................................... 38
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 1: Installation Prerequisites for Linux
This document describes the steps necessary to correctly install and configure all ANSYS, Inc. products
on Linux platforms for Release 16.2. These products include:
ANSYS Mechanical Products (includes Mechanical APDL and Mechanical, where supported)
ANSYS Autodyn
ANSYS LS-DYNA
ANSYS TurboGrid
ACIS
CATIA, Version 4
CATIA, Version 5
NX
Parasolid
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Installation Prerequisites for Linux
Notes Not all products may be available on all Linux platforms. Please see the remainder of this
document for detailed information on which products are available on which platforms.
At Release 16.2, ANSYS BladeGen, Vista CCD, Vista CPD, Vista RTD, and Vista AFD are not supported on
Linux platforms.
ANSYS Workbench and ANSYS EKM Desktop are installed by default as product components to most
ANSYS, Inc. products. ANSYS Workbench is not installed as part of the products under ANSYS Additional
Tools. ANSYS Workbench includes the following applications:
DesignModeler
Design Exploration
Meshing
Fluent Meshing
FE Modeler
EKM Client
Important Notice
If you wish to run multiple releases of ANSYS, Inc. software, you MUST install them chronologically (i.e.,
Release 16.1 followed by Release 16.2). If you install an earlier release after installing Release 16.2, you
will encounter licensing issues that may prevent you from running any products/releases. If you need
to install an earlier release after you have already installed Release 16.2, you MUST uninstall Release
16.2, then re-install the releases in order.
Supported Platforms for High Performance Computing Please see the discussions on Configuring
Distributed ANSYS and Configuring ANSYS CFX Parallel later in this guide for detailed information on
supported platforms for distributed computing.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
Disk Space and Memory Requirements
A = Mechanical APDL
W = ANSYS Workbench
I = ANSYS ICEM CFD standalone (some CAD systems may require the integrated ANSYS Work-
bench Reader)
Linux x64
CATIA 4.2.4 A,I
CATIA V56R2014 W, I
GAMBIT 2.4 W, I
Parasolid 26.0 A, W, I
ACIS 25 1 A, W, I
NX 8.5 A, W, I
NX 9.0 A, W, I
NX 10.0 A, W, I
STEP AP203, AP214 W,
IGES A 2, W, I 3
GEMS I
Rhinoceros I
1. For ANSYS ICEM CFD standalone, ACIS 18.0.1 is the supported version for all platforms.
2. MAPDL supports 5.1 by default, but 5.2 is also supported if the IOPTN command is used.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
Installation Prerequisites for Linux
Memory Requirements You must have a minimum of 8 GB of memory to run product installations;
16 or 32 GB of memory is recommended.
The machine(s) being used for the simulation must contain at least one supported nVIDIA GPU card or one
Intel Xeon Phi coprocessor. The following cards are supported:
For nVIDIA GPU cards, the driver version must be 331.75 or newer.
For Intel Xeon Phi coprocessors, the driver version must be MPSS 3.4 or newer.
Note
Mechanical APDL assumes that the Intel Xeon Phi coprocessor driver is installed in /opt/in-
tel/mic/coi. If the installation is located in a different folder, set the ANS_MIC_LIB_PATH
environment variable to the path where the Xeon Phi driver is installed (for example,
/mypath/mic/coi).
8 GB of RAM
TCP/IP for the license manager (see the ANSYS, Inc. Licensing Guide for more information on TCP/IP)
Approximately twice as much swap space as memory. The amount of memory swap space on the system
may limit the size of the model that can be created and/or solved.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
Third-Party Software and Other Security Considerations
Graphics card compatible with the supported operating systems, capable of supporting 1024x768 High
Color (16-bit) and a 17-inch monitor compatible with this type of graphics card; ANSYS CFX products and
ANSYS TurboGrid require 24-bit color and that antialiasing on your graphics card be disabled. Refer to your
operating system's documentation for specific instructions.
Note
A number of cosmetic display issues have been reported when running the installation
program on Linux platforms using AMD graphics cards. These issues do not affect the
installation functionality.
Use of Ultra High Definition (4K) graphics cards cause a number of cosmetic display issues
(including enlarged or reduced text and incorrect positioning of option labels). These
issues do not affect the installation functionality.
Mesa-libGL (OpenGL) is required to run data-integrated ANSYS Workbench applications such as Mechanical.
For Fluent, CFX-Pre, and CFD-Post, a three-button mouse is required to access all available functionality.
PDF reader software is required to read the installation guides and other user documentation.
ANSYS, Inc. products may have softlinks that require 777 permissions. In addition, the following third-
party products are known to contain softlinks that require 777 permissions:
CPython
GCC
HPMPI
IMPI
INTELMPI
MainWin
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
Installation Prerequisites for Linux
Mono
MPICH
OPENMPI
PCMPI
Perl
Python
Qt
Qwt
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 2: Platform Details
Linux
For ALL 64-bit Linux platforms, OpenMotif, and Mesa libraries should be installed. These libraries are
typically installed during a normal Linux installation. You will also need the xpdf package to view the
online help.
You can find the necessary OpenMotif libraries for your platform at http://www.motifzone.net.
SUSE Linux Enterprise 11 requires SP2 or SP3. After installing the SP2/SP3 updates, you must also install
OpenMotif and the prerequisites from the SLES11 SDK DVD, as well as the OpenMotif22 packages (re-
commended packages are openmotif22-libs-2.2.4-138.18.1.x86_64.rpm and openmotif22-libs-32bit-2.2.4-
138.18.1.x86_64.rpm from SLED11 SP1 x86_64 distribution. You may need to use "rpm -iv -force" to install
these).
Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 6 base install requires patch kernel-2.6.32-
71.14.1.el6.x86_64.rpm and kernel-devel-2.6.32-71.14.1.el6.x86_64.rpm.
libXp.x86_64
xorg-x11-fonts-cyrillic.noarch
xterm.x86_64
openmotif.x86_64
compat-libstdc++-33.x86_64
libstdc++.x86_64
libstdc++.i686
gcc-c++.x86_64
compat-libstdc++-33.i686
libstdc++-devel.x86_64
libstdc++-devel.i686
compat-gcc-34.x86_64
gtk2.i686
libXxf86vm.i686
libSM.i686
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
Platform Details
libXt.i686
xorg-x11-fonts-ISO8859-1-75dpi.noarch
Red Hat no longer includes the 32-bit libraries in the base configuration so you must install those sep-
arately.
Additional requirements for Intel, AMD Opteron, and EM64T Linux systems are detailed below.
ANSYS, Inc. License Manager Linux x64 systems running the ANSYS, Inc. License Manager require
the Linux Standard Base (LSB) 3.0 package.
CATIA V4 with Mechanical APDL To run CATIA V4 with Mechanical APDL on Linux 64-bit platforms,
you must have the following Linux 32-bit i686 libraries:
glibc
libstdc++
ANSYS Workbench If you are running ANSYS Workbench using the KDE desktop environment, set
the focus stealing prevention level to "None" to prevent the project save dialog boxes from appearing
behind the application window:
4. Click Apply.
If you are running on KDE 4 or if the kcontrol command does not exist, use System Settings to set
the focus stealing prevention setting level to "None":
4. Click Apply.
Semaphore Limit On some Linux systems, ANSYS Workbench reaches a system limit on the number
of semaphores in the Linux configuration. In this case, you will see a message similar to the following:
To increase the number of semaphores, run the following command as owner or root:
% echo 256 40000 32 32000 > /proc/sys/kernel/sem
This modification takes effect immediately, but is reset at the next reboot. To avoid resetting the limit
when rebooting, add the above command to one of your systems startup scripts by copying the com-
mand into a file called mod_sem and then setting up the following links to execute the file each time
you restart your system:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
cp mod_sem /etc/init.d
ln -s /etc/init.d/mod_sem /etc/rc3.d/S61mod_sem
ln -s /etc/init.d/mod_sem /etc/rc5.d/S61mod_sem
Mechanical, Meshing, DesignModeler, and FE Modeler Applications If you are using a localized
operating system (such as French or German), you must set the mwcontrol VisualMainWin control on
any machines running these applications in order for these applications to recognize the correct numer-
ical format. ANSYS Workbench must already be installed before setting this control.
First, you need to ensure that the /v162/aisol/WBMWRegistry/ directory has write permissions.
From the /v162/aisol/ directory, issue the following command:
chmod -R 777 WBMWRegistry/
Then, use the following procedure to set mwcontrol for your locale:
1. cd to <wb_install directory>/v162/aisol
5. Change the language in the dropdown to match the language you want to use.
7. Click Apply to accept the changes, and then click OK to dismiss the Change Regional Settings notification.
Using Fluent with Infiniband On some operating systems, the default amount of physical memory
that can be pinned/locked by a user application is set to a low value and must be explicitly increased.
A value recommended by Intel is 90% of the physical memory. Therefore, the following should be added
to the /etc/security/limits.conf file:
* hard memlock unlimited
* soft memlock unlimited
The need for increasing the limits may be indicated by the following error message with Platform MPI:
fluent_mpi.16.0.0: Rank 0:1: MPI_Init: ibv_create_cq() failed
fluent_mpi.16.0.0: Rank 0:1: MPI_Init: Can't initialize RDMA device
fluent_mpi.16.0.0: Rank 0:1: MPI_Init: MPI BUG: Cannot initialize RDMA protocol
libibverbs: Warning: RLIMIT_MEMLOCK is 32768 bytes.
This will severely limit memory registrations
When Fluent is launched by a scheduler (like PBSPro, SGE, etc.), these limits may be reset by the
scheduler. You may check running the limit command within and without the scheduler to compare.
Any differences indicate the issue above.
If you use PBSPro, add ulimit -l unlimited directly in the pbs_mom startup script, and let PBS
reload the pbs_mom.
If you use SGE, you must change the startup script /etc/init.d/sgeexecd to include the ulimit
-l unlimited command as shown in the following example:
-- BEGIN --
if [ "$startup" = true ]; then
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
Platform Details
Once this modification is in place, restart SGE to set the correct memory limits on the SGE daemon and
any invoked processes.
Using Mechanical APDL with Infiniband On some operating systems, the default amount of physical
memory that can be pinned/locked by a user application is set to a low value and must be explicitly
increased. A value recommended by Intel is 90% of the physical memory. Therefore, the following
should be added to the /etc/security/limits.conf file:
* hard memlock unlimited
* soft memlock unlimited
This behavior has been observed on Intel MPI 4.1.3, but might also occur on Platform MPI 9.1.2.1.
Using the Fluent Launcher On Linux systems, you must have the following package (as appropriate
for your platform) installed in order to use the Fluent launcher:
Using ANSCUSTOM If you use ANSCUSTOM to link your own version of ANSYS Release 16.2 on a
SUSE SLES 11.x computer, you may see two unsatisfied externals that are system, not ANSYS files, due
to the linker looking for some system files in a Red Hat directory on a SUSE computer.
The revision numbers shown in the examples (2.95.3 and 3.4.6) may be different on your system. The
linker will specify where it is trying to find the crtbegin.o and crtend.o files; that location will be
the last part of the above commands. You can use the Linux locate command to find the existing
crtbegin.o and crtend.o files; that location would be the first part of the above commands.
System Libraries On 64-bit Linux linx64 systems, the ANSYS Release 16.2 executable is looking for
system libraries that do not have revision numbers appended to the end of their file names. On some
SUSE systems, the graphics libraries all have revision numbers appended to the end of the library file-
names. In these cases, ANSYS quits because the loader cannot find all of the libraries that it is looking
for. When running ANSYS Release 16.2, the loader will inform you that it is unable to locate a specific
library (for example, libXm.so). Using the Linux locate command, find the library (libXm.so in
this example) on your system and add the appropriate symbolic link as seen below.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
Compiler Requirements for Linux Systems
The revision numbers appended to the filenames on the left may be different on your system.
Intel Linux
ANSYS was built and tested on Red Hat using the compilers as noted in Table 2.1: Compiler Requirements
for All Linux Versions (p. 11). The ANSYS solver is built on Red Hat Enterprise Linux AS release 4 (Update
5).
For ANSYS Workbench and ANSYS Autodyn, you may need to increase the stack size; we recommend
setting it to 1 GB. Add the following to your configuration file:
Other shells may have different settings; please refer to your shell documentation for specific details.
If you are running on Intel's Xeon EM64T system, we recommend that you turn CPU hyperthreading
off (default is on). A system administrator needs to reboot the system and enter the BIOS to turn
the hyperthreading option off.
* Compilers are required only if you will be using User Programmable Features (UPF), User Defined
Functions (UDF), or other customization options.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
Platform Details
Installing the ANSYS Software for a Stand-alone Linux System (p. 13)
Installing the ANSYS Products and the License Server on Different Linux Machines (p. 21)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 3: Installing the ANSYS Software for a Stand-alone Linux
System
This section explains how to install ANSYS, Inc. products, including ANSYS client licensing, as well as
the ANSYS, Inc. License Manager.
The default installation expects you to be logged in as root. You can install as non-root; however, if you
are not logged in as root, you will not be able to set the /ansys_inc symbolic link and may potentially
experience permission problems. The inability to set the /ansys_inc symbolic link will in no way in-
hibit your ability to run ANSYS, Inc. products; it is provided as a convenience.
If you do not use the /ansys_inc symbolic link, you must install all releases into a common directory
to ensure license manager compatibility and availability among releases and products.
If you did not use the /ansys_inc symbolic link, you must replace all references to /ansys_inc/v162
or <install_dir> with the actual installation path you used.
An account on the ANSYS Customer Portal. If you do not have an account, you may register at https://sup-
port.ansys.com/portal/site/AnsysCustomerPortal to receive your own account.
Your license file from ANSYS, Inc., saved to a temporary directory. For more information, see Registering the
License Server (p. 20).
Open port numbers for both the FLEXlm and ANSYS Licensing Interconnect. Defaults are 1055 and 2325,
respectively. To verify that these port numbers are available, open a command line and enter the following
command:
netstat -a -t
You will see a list of active ports. If 1055 and 2325 are listed, they are already in use and cannot be
used for ANSYS, Inc. licensing. In this case, you will need to specify different port numbers where in-
dicated later in this installation.
You should also verify that you are running on a supported platform. ANSYS, Inc. products support 64-
bit Linux systems running Red Hat 6 (6.4 and 6.5) and SUSE Linux Enterprise 11 (SP2 or SP3).
Verify that you have sufficient disk space to download, uncompress, and install the products you will
be installing. Approximate disk space requirements for each product are shown in Disk Space and
Memory Requirements (p. 3).
If you have any problems with--or questions about--the installation process, log a Service Request on
the ANSYS Customer Portal to have a Systems Support Specialist assist you.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
Installing the ANSYS Software for a Stand-alone Linux System
Product Download Instructions: This set of instructions describes the download and extraction process.
Product Installation with Client Licensing: This set of instructions describes the product installation, including
the client licensing portion.
License Manager Installation: This set of instructions describes the license manager installation.
Post-Installation Procedures for All Products: This is a set of instructions that describes any configuration
steps that may be required for the various products.
Both the product and the license manager will be installed on the same machine. You must complete
both the client licensing portion and the license manager installation in order to run ANSYS, Inc. products.
Depending on the product/platform combination(s) you choose, you may need to download multiple
files.
Step 1 of the ANSYS Download Center Select Full Products page is displayed.
Primary Packages: Individual full packages for the primary ANSYS products.
7. To download Add-On Packages, Tools or Academic Packages, click the + to the right of the appropriate
product group title to display the download options and download as required.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
Mounting the DVD Instructions for DVD Installations (Linux x64 Only)
8. After all downloads have been completed, uncompress each package using standard uncompression
utilities for your specific platform. We strongly recommend that you extract the files into new, temporary
directories.
3.4. Mounting the DVD Instructions for DVD Installations (Linux x64 Only)
If you install ANSYS, Inc. products from the installation media (DVD), you will need to run the installation
procedure using either a locally- or remotely-mounted DVD, depending on your site's system.
Note
Typically, a Linux system will mount a local DVD for you under /media/ANSYS162.
If the target machine does not have a DVD reader, first follow the steps for locally-mounted DVD, and
then follow the procedure below for remotely-mounted DVDs:
1. Add the dvdrom_dir directory to the /etc/exports file on the machine with the DVD device. A
sample /etc/exports entry is:
/dvdrom_dir *(ro)
or
/dvdrom_dir (ro)
Check the manual page for 'exports' for the correct syntax, as different Linux versions can have
different syntax.
3. Log on to the machine where you wish to install ANSYS, Inc. products and issue the following commands:
mkdir dvdrom_dir2
mount -t nfs Host:cdrom_dir dvdrom_dir2
where Host is the hostname of the machine where the DVD device is located.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
Installing the ANSYS Software for a Stand-alone Linux System
From the options along the left side of the launcher you can install ANSYS products, Documentation
Only, ANSYS EKM Server, and the ANSYS License Manager. You can access the installation guide
for the ANSYS EKM Server from the Downloads page on the Customer Portal.
The ANSYS, Inc. Quick Start Installation Guide, ANSYS, Inc. Quick Start Licensing Guide, System Re-
quirements Guide and complete Installation Help Guide can be accessed through the options located
along the bottom of the launcher.
Select the language you want to use from the drop-down menu in the upper right corner. English
is the default.
4. The license agreement appears. Read the agreement, and if you agree to the terms and conditions, select
I Agree. Click Next.
5. The directory where you wish to install the ANSYS, Inc. products is shown in the Install Directory field.
You can install the products into any directory you wish, but you must have write permissions to the dir-
ectory you choose. The default is /ansys_inc. We recommend using the default directory.
The Symbolic Link option is available only if you are installing as root and is enabled (checked)
by default. If you choose to disable (uncheck) the symbolic link or are installing as a non-root user,
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Installation
substitute the directory path where you installed the product for all subsequent occurrences of
/ansys_inc in this guide.
We strongly recommend that you use the Symbolic Link option. If you do not use this option, you
must install all releases into a common directory to ensure license manager compatibility and
availability among releases and products.
If you have already installed the ANSYS Workbench Framework for Ansoft, you must install any
additional ANSYS, Inc. products into the same directory.
On Linux, you can choose Disable RSS to disable automatic internet feeds to ANSYS, Inc. products.
Click Next.
6. If this is a first time installation, you are prompted to enter your license server specification. If you already
have an existing license server specification file, you will not see this window and proceed directly to the
next step.
Enter your ANSYS Licensing Interconnect port number and your ANSYS FlexNet port number. Defaults
are provided and will work in most cases. You may need to check with your IT department to
confirm that the default port numbers are valid or to get different port numbers if necessary.
Click Next.
7. All products available in the installation package(s) you downloaded are listed.
The installation program attempts to query your license server to pre-select your installation options.
If the query is successful, the following message is displayed:
Your installation options were pre-selected based upon information from your license server.
You can select or deselect any combination of products. ANSYS Workbench is automatically installed
with most ANSYS, Inc. products; there is no individual product selection for ANSYS Workbench.
If you select NX or Catia V5, you will have additional installation steps. This installation assumes
you are not installing these CAD packages. Deselect these options before continuing.
By default, the Install Documentation option is enabled (checked). When enabled, help document-
ation is included as part of the installation process for all products selected. No help documentation
is included with the installation if this box is disabled (unchecked).
You will also see an estimate of the disk space required to install all of the selected components,
and the disk space you have available. The actual amount of disk space required may be less, but
if you choose to run the installation with insufficient disk space available, we strongly recommend
that you review the log files at the end of the installation to verify that all products were installed
correctly. Installation log files are written to the installation directory.
Note
On a first time installation, if you chose to install any ANSYS Geometry Interfaces, en-
sure that you have also selected at least one ANSYS, Inc. product as part of the in-
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
Installing the ANSYS Software for a Stand-alone Linux System
The dates on the licensing files being installed are compared to any that may already exist on your
machine. (This may take a few moments.)
8. A summary screen appears listing your installation selections. Please review this list carefully to verify that
it is correct. When you are sure all selections are correct, click Next to begin the installation.
9. The installation progress screen displays a status bar towards the bottom of the installation window. This
status bar tracks the percentage of packages that have been installed on your computer. Depending on
the number of products you have selected, the installation time required could be lengthy. You will not
be able to interrupt the installation process. Please be patient while the installation completes.
Note
Clicking the View Details Progress Log button opens a second window that displays
the name of each product package as it is uncompressed and installed.
10. The product installation window reappears with a message noting that the installation is complete. A
Launch Survey Upon Exiting option is included here. Clicking Exit while the Launch Survey Upon Ex-
iting is enabled causes your default browser to open, displaying the product survey. Disabling (un-
checking) the Launch Survey Upon Exiting option and then clicking Exit skips the survey.
The ANSYS, Inc. Installation Launcher appears. For this stand-alone installation, you must complete
the License Manager installation (next) to run ANSYS, Inc. products.
1. Navigate to the directory where you extracted the files. Run ./INSTALL.LM. If you downloaded the license
manager installation package, this file will reside in the directory where you untarred the downloaded
files. If you are running from a DVD, this file will reside in the top level of the DVD.
2. You may see a warning stating that if the license manager is currently running, it will be shut down. This
installation assumes that you have not previously installed the products or the licensing on this machine,
and you are not pointing to a network license server machine. You may safely ignore this message and
click OK.
4. The license agreement appears. Read the agreement, and if you agree to the terms and conditions, select
I Agree. Click Next.
5. The directory where you wish to install the ANSYS, Inc. License Manager is shown in the Install Directory
field. You can install the License Manager into any directory you wish, but you must have write permissions
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Installation
to the directory you choose. The default is /ansys_inc. We recommend using the default directory.
You must use the same directory where the products were installed.
Note
You are unable to change the installation directory for a computer that currently contains
an instance of the ANSYS, Inc. License Manager or ANSYS Electromagnetics License
Manager. To change the installation directory location, you must first uninstall any pre-
vious versions of both products.
6. The ANSYS, Inc. License Manager is selected as the only product available to install. As with the product
installation, the required and available disk space numbers are shown. Click Next.
7. A summary screen appears that lists the products to be installed. Because this is a license manager install-
ation, the ANSYS, Inc. License Manager is the only product listed.
The ANSYS, Inc. License Manager is now being installed and configured on your system. After the
License Manager installation has been completed, the Launch License Management Center upon
exiting option is included on the screen. The ANSYS License Management Center is a browser-
based user interface that centralizes many of the ANSYS product licensing administrative functions.
If you do not wish to launch the License Management Center, uncheck the Launch License Man-
agement Center upon exiting option.
10. Open a terminal window and navigate to your ANSYS installation. The following table lists the default
paths to start the ANSYS products you have installed.
Application Locations
Application How to Launch
ACP /ansys_inc/v162/ACP.sh
CFD Post /ansys_inc/v162/cfdpost
CFX /ansys_inc/v162/CFX/bin/<productname>
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
Installing the ANSYS Software for a Stand-alone Linux System
1. Open the ANSYS License Management Center. To run the ANSYS License Management Center on Linux
run the following script:.
/shared_files/licensing/start_lmcenter
2. Click the Get System Hostid Information option to display your system ID code(s).
3. Select the system ID you wish to use and click SAVE TO FILE.
4. Forward this text file to your ANSYS sales representative so that a license file can be created for you.
5. Add your license files though the ANSYS License Management Center. For these steps, see Adding a License
with the ANSYS License Management Center.
After completing the installation process, please refer to Post-Installation Instructions (p. 31).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 4: Installing the ANSYS Products and the License Server on
Different Linux Machines
This section explains how to install ANSYS, Inc. products, including ANSYS client licensing, as well as
the ANSYS, Inc. License Manager.
The default installation expects you to be logged in as root. You can install as non-root; however, you
will not be able to set the /ansys_inc symbolic link and may potentially experience permission
problems. The inability to set the /ansys_inc symbolic link will in no way inhibit your ability to run
ANSYS, Inc. products; it is provided as a convenience when navigating to the /ansys_inc directory.
If you do not use the /ansys_inc symbolic link, you must install all releases into a common directory
to ensure license manager compatibility and availability among releases and products.
If you did not use the /ansys_inc symbolic link, you must replace all references to /ansys_inc/v162
or <install_dir> with the actual installation path you used.
An account on the ANSYS Customer Portal. If you do not have an account, you may register at https://sup-
port.ansys.com/portal/site/AnsysCustomerPortal to receive your own account.
Your license file from ANSYS, Inc., saved to a temporary directory. For more information, see Registering the
License Server (p. 28).
Open port numbers for both the FLEXlm and ANSYS Licensing Interconnect. Defaults are 1055 and 2325,
respectively. To verify that these port numbers are available, open a command line and enter the following
command:
netstat -a -t
You will see a list of active ports. If 1055 and 2325 are listed, they are already in use and cannot be
used for ANSYS, Inc. licensing. In this case, you will need to specify different port numbers where in-
dicated later in this installation.
You should also verify that you are running on a supported platform. ANSYS, Inc. products support 64-
bit Linux systems running Red Hat 6 (6.4 and 6.5) and SUSE Linux Enterprise 11 (SP2 or SP3). For detailed
information on which products are supported on which platforms, please see the ANSYS, Inc. Linux In-
stallation Guide, which is available for download when you download ANSYS, Inc. products or as a
printed manual if you receive installation media.
Verify that you have sufficient disk space to download, uncompress, and install the products you will
be installing. Approximate disk space requirements for each product are shown in Disk Space and
Memory Requirements (p. 3).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
Installing the ANSYS Products and the License Server on Different Linux Machines
If you have any problems with--or questions about--the installation process, log a Service Request on
the ANSYS Customer Portal to have a Systems Support Specialist assist you.
Product Download Instructions: This set of instructions describes the download and extraction process.
Product Installation with Client Licensing: This set of instructions describes the product installation, including
the client licensing portion.
License Manager Installation: This set of instructions describes the license manager installation.
Post-Installation Procedures for All Products: This is a set of instructions that describes any configuration
steps that may be required for the various products.
For this procedure, the product and the license manager will be installed on separate machines. You
must complete both the client licensing portion and the license manager installation in order to run ANSYS,
Inc. products.
Depending on the product/platform combination(s) you choose, you may need to download multiple
files.
Step 1 of the ANSYS Download Center Select Full Products page is displayed.
Primary Packages: Individual full packages for the primary ANSYS products.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
Mounting the DVD Instructions for DVD Installations (Linux x64 Only)
7. To download Add-On Packages, Tools or Academic Packages, click the + to the right of the appropriate
product group title to display the download options and download as required.
8. After all downloads have been completed, uncompress each package using standard uncompression
utilities for your specific platform. We strongly recommend that you extract the files into new, temporary
directories.
4.4. Mounting the DVD Instructions for DVD Installations (Linux x64 Only)
If you install ANSYS, Inc. products from the installation media (DVD), you will need to run the installation
procedure using either a locally- or remotely-mounted DVD, depending on your site's system.
Note
Typically, a Linux system will mount a local DVD for you under /media/ANSYS162.
If the target machine does not have a DVD reader, first follow the steps for locally-mounted DVD, and
then follow the procedure below for remotely-mounted DVDs:
1. Add the dvdrom_dir directory to the /etc/exports file on the machine with the DVD device. A
sample /etc/exports entry is:
/dvdrom_dir *(ro)
or
/dvdrom_dir (ro)
Check the manual page for 'exports' for the correct syntax, as different Linux versions can have
different syntax.
3. Log on to the machine where you want to install ANSYS, Inc. products and issue the following commands:
mkdir dvdrom_dir2
mount -t nfs Host:cdrom_dir dvdrom_dir2
where Host is the hostname of the machine where the DVD device is located.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
Installing the ANSYS Products and the License Server on Different Linux Machines
From the options along the left side of the launcher you can install ANSYS products, Documentation
Only, ANSYS EKM Server, and the ANSYS License Manager. You can access the installation guide
for the ANSYS EKM Server from the Downloads page on the Customer Portal.
The ANSYS, Inc. Quick Start Installation Guide, ANSYS, Inc. Quick Start Licensing Guide, System Re-
quirements Guide and complete Installation Help Guide can be accessed through the options located
along the bottom of the launcher.
Select the language you want to use from the drop-down menu in the upper right corner. English
is the default.
4. The license agreement appears. Read the agreement, and if you agree to the terms and conditions, select
I Agree. Click Next.
When installing more than one platform or if you are installing a platform other than your current
machine type, you will need to select the platform(s) on which you want to install the ANSYS, Inc.
products. The platform on which you launched the installation will be selected by default and is
shown at the bottom of the window. You can choose as many platforms as you want; however,
you must run the platform configuration procedure (see Run the Product Configuration Utility in
Network Installation and Product Configuration (p. 28)) for each platform other than your current
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Installation
machine type. See Network Installation and Product Configuration (p. 28) for specific instructions
on how to configure a shared installation directory across multiple machines using a common
network file system.
5. The directory where you want to install the ANSYS, Inc. products is shown in the Install Directory field.
You can install the products into any directory you want, but you must have write permissions to the
directory you choose. The default is /ansys_inc. We recommend using the default directory.
The Symbolic Link option is available only if you are installing as root and is enabled (checked)
by default. If you choose to disable (uncheck) the symbolic link or are installing as a non-root user,
substitute the directory path where you installed the product for all subsequent occurrences of
/ansys_inc in this guide.
We strongly recommend that you use the Symbolic Link option. If you do not use this option, you
must install all releases into a common directory to ensure license manager compatibility and
availability among releases and products.
If you have already installed the ANSYS Workbench Framework for Ansoft, you must install any
additional ANSYS, Inc. products into the same directory.
On Linux, you can choose Disable RSS to disable automatic internet feeds to ANSYS, Inc. products.
Click Next.
6. If this is a first time installation, you are prompted to enter your license server specification. If you already
have an existing license server specification file, you will not see this window and proceed directly to the
next step.
Enter your ANSYS Licensing Interconnect port number and your ANSYS FlexNet port number. Defaults
are provided and will work in most cases. You may need to check with your IT department to
confirm that the default port numbers are valid or to get different port numbers if necessary.
Click Next.
7. All products available in the installation package(s) you downloaded are listed.
The installation program attempts to query your license server to pre-select your installation options.
If the query is successful, the following message is displayed:
Your installation options were pre-selected based upon information from your license server.
You can select or deselect any combination of products. ANSYS Workbench is automatically installed
with most ANSYS, Inc. products; there is no individual product selection for ANSYS Workbench.
If you select NX or Catia V5, you will have additional installation steps. This installation assumes
you are not installing these CAD packages. Deselect these options before continuing.
By default, the Install Documentation option is enabled (checked). When enabled, help document-
ation is included as part of the installation process for all products selected. No help documentation
is included with the installation if this box is disabled (unchecked).
You will also see an estimate of the disk space required to install all of the selected components,
and the disk space you have available. The actual amount of disk space required may be less, but
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
Installing the ANSYS Products and the License Server on Different Linux Machines
if you choose to run the installation with insufficient disk space available, we strongly recommend
that you review the log files at the end of the installation to verify that all products were installed
correctly. Installation log files are written to the installation directory.
Note
On a first time installation, if you chose to install any ANSYS Geometry Interfaces, en-
sure that you have also selected at least one ANSYS, Inc. product as part of the in-
stallation. Installing an ANSYS Geometry Interface without an underlying ANSYS,
Inc. product on a first time installation may cause installation errors.
Select the products you want to install and click Next.The dates on the licensing files being installed
are compared to any that may already exist on your machine. (This may take a few moments.)
8. A summary screen appears listing your installation selections. Please review this list carefully to verify that
it is correct. When you are sure all selections are correct, click Next to begin the installation.
9. The installation progress screen displays a status bar towards the bottom of the installation window. This
status bar tracks the percentage of packages that have been installed on your computer. Depending on
the number of products you have selected, the installation time required could be lengthy. You will not
be able to interrupt the installation process. Please be patient while the installation completes.
Note
Clicking the View Details Progress Log button opens a second window that displays
the name of each product package as it is uncompressed and installed.
10. The product installation window reappears with a message noting that the installation is complete. A
Launch Survey Upon Exiting option is included here. Clicking Exit while the Launch Survey Upon Ex-
iting is enabled causes your default browser to open, displaying the product survey. Disabling (un-
checking) the Launch Survey Upon Exiting option and then clicking Exit skips the survey.
11. If you have installed ANSYS, Inc. products on a file server, follow the instructions under Network Installation
and Product Configuration (p. 28).
1. Navigate to the directory where you extracted the files. Run ./INSTALL.LM. If you downloaded the license
manager installation package, this file will reside in the directory where you untarred the downloaded
files. If you are running from a DVD, this file will reside in the top level of the DVD.
2. You may see a warning stating that if the license manager is currently running, it will be shut down. If
you have not previously installed the products or the licensing on this machine, and you are not pointing
to a network license server machine, you may safely ignore this message and click OK.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Installation
4. The license agreement appears. Read the agreement, and if you agree to the terms and conditions, select
I Agree. Click Next.
5. The directory where you want to install the ANSYS, Inc. License Manager is shown in the Install Directory
field. You can install the License Manager into any directory you want, but you must have write permissions
to the directory you choose. The default is /ansys_inc. We recommend using the default directory.
You must use the same directory where the products were installed.
Note
You are unable to change the installation directory for a computer that currently contains
an instance of the ANSYS, Inc. License Manager or ANSYS Electromagnetics License
Manager. To change the installation directory location, you must first uninstall any pre-
vious versions of both products.
6. The ANSYS, Inc. License Manager is selected as the only product available to install. As with the product
installation, the required and available disk space numbers are shown. Click Next.
7. A summary screen appears that lists the products to be installed. Because this is a license manager install-
ation, the ANSYS, Inc. License Manager is the only product listed.
The ANSYS, Inc. License Manager is now being installed and configured on your system. After the
License Manager installation has been completed, the Launch License Management Center upon
exiting option is included on the screen. The ANSYS License Management Center is a browser-
based user interface that centralizes many of the ANSYS product licensing administrative functions.
If you do not want to launch the License Management Center, uncheck the Launch License Man-
agement Center upon exiting option.
10. Open a terminal window and navigate to your ANSYS installation. The following table lists the default
paths to start the ANSYS products you have installed.
Application Locations
Application How to Launch
ACP /ansys_inc/v162/ACP.sh
CFD Post /ansys_inc/v162/cfdpost
CFX /ansys_inc/v162/CFX/bin/<productname>
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
Installing the ANSYS Products and the License Server on Different Linux Machines
1. Open the ANSYS License Management Center. To run the ANSYS License Management Center on Linux
run the following script:.
/shared_files/licensing/start_lmcenter
2. Click the Get System Hostid Information option to display your system ID code(s).
3. Select the system ID you wish to use and click SAVE TO FILE.
4. Forward this text file to your ANSYS sales representative so that a license file can be created for you.
5. Add your license files though the ANSYS License Management Center. For these steps, see Adding a License
with the ANSYS License Management Center.
A network installation must be homogeneous, although you can install on different operating systems.
You must complete the following steps to run products across a network:
4.5.2.1. Export the /ansys_inc Directory
4.5.2.2. Run the Product Configuration Utility on All Client Machines
We strongly recommend that these steps be performed by the same non-root user. Installing and con-
figuring as different users may create permissions problems. Likewise, installing and/or configuring as
a root user may also result in permissions problems.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Installation
The instructions below assume ANSYS, Inc. products were installed in the specified directory.
1. Install the ANSYS, Inc. products. The following example uses /usr/ansys_inc.
2. Export the ansys_inc directory by adding the following line to the /etc/exports file:
/usr/ansys_inc
The default behavior on Linux provides read-only access from all clients. To enable read/write
permission from all clients, use *(rw):
/usr/ansys_inc *(rw)
3. Run
exportfs -a
If you perform a network install where you want the clients to be able to modify the licensing configur-
ation, you need to consider the NFS write options for the exported file system as shown in the above
examples. You also need local permissions to the licensing directory (/shared_files/licensing/)
if you want to be able to create the install_licconfig.log that the license configuration produces.
If you need to transfer the files from a Windows machine with a DVD drive to a Linux machine without
one, copy the DVD contents using a Samba mount or some other transfer method that is safe to use
between Windows and Linux.
If sharing the ANSYS directory between Linux machines, you must use the same mount point for both
the client and server. For example, if you installed to a file server in a directory named /apps/an-
sys_inc and you did not choose the symbolic link to /ansys_inc, then you must mount this directory
on the client machine using /apps/ansys_inc as the mount point. If you did choose the symbolic
link to /ansys_inc during installation on the file server, you must either use /ansys_inc as the
mount point on the client or you must create a symbolic link to /ansys_inc on the client machine.
(The symbolic link is created by default during installation if you installed as root).
Note
The username and user ID utilized when running the Product Configuration Utility must be
the same as the installing server user.
1. On each client machine, issue the following command to run the Product Configuration utility:
/ansys_inc/v162/ProductConfig.sh
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 29
Installing the ANSYS Products and the License Server on Different Linux Machines
Note
ANSYS Workbench is configured when Mechanical APDL, ANSYS CFX, ANSYS Fluent,
ANSYS Polyflow, or Remote Solve Manager Standalone Services is selected. CFD-Post is
configured when either ANSYS CFX, ANSYS Fluent, ANSYS Polyflow or ANSYS Icepak is
configured.
After completing the installation process, please refer to Post-Installation Instructions (p. 31).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
30 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 5: Post-Installation Instructions
The following post-installation procedures apply to all ANSYS, Inc. products. Individual products may
have additional post-installation procedures; please refer to the following sections for each product.
5.1. Post-Installation Procedures for Mechanical APDL and ANSYS Workbench Products
5.2. Product Localization
5.3. Launching ANSYS, Inc. Products
Note
If the installation program reported any errors, please review the installation error file (in-
stall.err) located in the ANSYS Inc directory. Contact your ANSYS Support representative if
you have any questions.
After the product is installed, you need to establish some system settings, including path names and
environment variables. See your shell documentation or man pages file for the shell being used for
specific instructions on setting paths and environment variables.
1. Add the following paths to all users' login startup files (i.e., .cshrc , .profile, or .login files).
2. Set the following environment variables based on the behavior you want. Set the environment variables
following the conventions of your shell. For example, to set an environment variable in the C shell, type:
setenv environment_variable value
For example, to set the DISPLAY environment variable, you type the following, where dev is the
workstation hostname or IP address on which to display graphics:
setenv DISPLAY dev:0.0
DISPLAY - set this to the IP address or hostname of the workstation to which the users will
output their analysis results. Note that the X server must have permission to connect to the
host machine.
If you will be using connection functionality, you may have additional environment variables to
set. See the section Configuring CAD Products (p. 49) later in this guide for more information.
3. Set the license manager to start automatically at boot time. For platform-specific instructions, see License
Manager Automatic Startup Instructions in the ANSYS, Inc. Licensing Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 31
Post-Installation Instructions
4. Designate server(s) for license checkout and establish necessary user privileges (recommended but not
required). For information on these tasks, see Post-Installation Instructions for the License Manager in the
ANSYS, Inc. Licensing Guide.
5. Make a backup copy of the /ansys_inc directory using a tape backup command such as tar.
6. Verify the installation by logging out as root (if you installed as root) and logging back in as a regular user
and then starting the product to verify that it starts and runs correctly.
Quality Assurance Services: If you require verification of Mechanical APDL, the Mechanical Application,
Fluent, or CFX, ANSYS, Inc. offers Quality Assurance services. If you are interested in this service, go to
http://www.ansys.com/Support/Quality+Assurance/Quality+Services or call the ANSYS, Inc. Corporate
Quality Group at (724) 746-3304.
1. Set the following environment variables based on the behavior you want. Set the environment variables
following the conventions of your shell. Not all of these are required for all integrated ANSYS Workbench
products (such as ANSYS Autodyn), but setting them correctly for ANSYS Workbench will in no way hinder
the performance of the other products.
The ANSYS162_DIR environment variable sets the location of the ANSYS directory hierarchy.
The default value is /ansys_inc/v162/ansys. You probably will not need to reset this
variable, unless you change the location of the installed files.
The ANSYSLIC_DIR environment variable sets the location of the ANSYS licensing directory
hierarchy. The default value is /ansys_inc/shared_files/licensing . You probably
will not need to reset this variable, unless you change the location of the licensing files.
ANSYS162_PRODUCT - set this to the correct product variable to run Mechanical APDL to
start with the correct product without specifying the -p command modifier each time. See the
Product Variable Table in the ANSYS, Inc. Licensing Guide for a list of valid product variables.
ANSYS_LOCK - set to ON (default) to create file locks to prevent users from opening a new
job with the same name and in the same directory as the current job.
ANSYS162_WORKING_DIRECTORY - set this variable to the directory you want designated as
your working directory. The working directory setting in the launcher will reflect this setting.
ANSYS162_MAT161 - set this environment variable to 1 to enable use of the LS-DYNA
*MAT_COMPOSITE_MSC material (requires an LS-DYNA MAT_161 license).
ANSYS162_MAT162 - set this environment variable to 1 to enable use of the LS-DYNA
*MAT_COMPOSITE_DMG_MSG material (requires an LS-DYNA MAT_162 license).
ANSBROWSER - set this environment variable to the browser on your system (specify the full
path) if the automatic browser detection fails. A browser is needed to view HTML reports and
help for the ANS_ADMIN utility and the Mechanical APDL launcher. By default, ANSBROWSER
points to one of several Linux browsers, based on the browser specified in your path (if any).
If you will be using connection functionality, you may have additional environment variables to
set. See the section Configuring CAD Products (p. 49) later in this guide for more information.
2. Create or update the at. files. The at.allow file should contain the username of all users allowed to
run batch jobs; the at.deny file should contain the username of users who are not permitted to run
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
32 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Procedures for Mechanical APDL and ANSYS Workbench Products
batch jobs. The files consist of one username per line and can be modified only by the superuser. If neither
file exists, only root will be able to run batch jobs.
The at. files are located in the /etc directory on Linux machines.
3. Run the ANS_ADMIN utility to properly configure ANSYS (depending on the products you are running)
or relink ANSYS.
4. Specify the product order as it will appear in the Mechanical APDL launcher (optional). If you want to
specify product order, use the ANSLIC_ADMIN utility. See the ANSYS, Inc. Licensing Guide for more inform-
ation.
Explicit Dynamics, Rigid Dynamics, My Computer Background, and Remote Solve Manager (RSM)
Users: If you are running ANSYS Workbench on a multi-user RSM machine, the My Computer, Back-
ground Solve Process Settings will likely not function as expected due to write permissions for RSM
working directories. In this situation, we strongly recommend that you set up RSM as a daemon.
This issue also affects Rigid Dynamics and Explicit Dynamics using both My Computer and My Computer,
Background Solve Process Settings. Please see Configuring a Multi-User RSM Machine in the RSM doc-
umentation for more information.
The Linux installation of ANSYS CFX or ANSYS TurboGrid automatically installs the Sun Java 2 Runtime
Environment in the /ansys_inc/v162/commonfiles/jre directory. Regardless of whether you
have modified your setup files, you can still run ANSYS CFX commands by specifying the full pathname
of the commands you want to run. This procedure may be useful if you have several releases of ANSYS
CFX installed and you want to run more than one release.
Unless you want to run ANSYS CFX commands by typing their full path names, for example cfx-
root/bin/cfx5 (where cfxroot is the directory in which ANSYS CFX is installed), your command
search paths must be modified to search the directory cfxroot/bin. This can be done by one of the
following methods:
Modification of individual user setup files You can select Tools> Configure User Startup Files
from the ANSYS CFX Launcher to modify your own setup files: .login for the C shell, .profile for
the Bourne and Korn shells. The utility can also be run from the command line by entering:
cfxroot/bin/cfx5setupuser
If this modification is done, the ANSYS CFX software will be available every time you log in, just by
running the ANSYS CFX commands by name. This method has the advantage that it need not be done
by the system administrator, but has the disadvantage that it must be done by each user.
If you choose to modify your setup files, you will see a message indicating that your setup files have
been changed. You will then need to log out and log in again or source your setup files before you can
use the software.
Manual execution of a setup script each time the software is used You can also use the Tools
menu of the launcher to launch an editor to create new setup scripts which need to be run each time
you want to use the ANSYS CFX software. This method has the advantage of not requiring changes to
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 33
Post-Installation Instructions
existing setup files and allows you to use different versions of ANSYS CFX software by running different
setup files. The disadvantages are that all users must create their own setup files and run them manually
in every session in which they want to run ANSYS CFX software.
Having created the setup files, users of the C shell then need to do the following to run ANSYS CFX:
source ~/cfx5.login
cfx5
Having created the setup files, users of the Bourne or Korn shell then need to do the following before
running ANSYS CFX:
.$HOME/cfx5.profile
cfx5
Modification of system setup files The system administrator modifies the setup files (normally
/etc/profile), which are run by all users during login, to include the directory cfxroot/bin in
the command search path. While this has the advantage of only one file needing to be modified in order
to allow all users to use the software, it also:
Is system dependent
Refer to your system documentation for information about which files to change for your workstations.
and these lines to the .profile file in your home directory, and also the .bash_profile if it exists:
PATH=cfxroot/bin:$PATH
export PATH
With the path altered in this way, you can start ANSYS TurboGrid in the current working directory by
typing cfxtg.
Modification of system setup files The system administrator modifies the setup files ( normally
etc/profile), which are run by all users during login, to include the directory cfxroot/bin in the
command search path. While this method has the advantage that only one file needs to be modified
to allow all users to use the software, it:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
34 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Procedures for Mechanical APDL and ANSYS Workbench Products
Is system dependent
Refer to your system documentation for information about which files to change for your workstations.
and select Tools> Configure User Startup Files. This option runs cfxroot/bin/cfx5setupuser
that modifies your setup files or writes the necessary commands to files, which you can merge manually
with your existing setup files.
If you choose to modify your setup files, you will see a message indicating that your setup files have
been changed. You will then need to log out and log in again or source your setup files before you can
use the software.
User setup can also be run from the command line by entering:
cfxroot/bin/cfx5setupuser
To keep all the files for the example together, you should first create a new directory in which to run
the example. This can be done by typing:
mkdir cfx_example
at the command line. You should then change to this directory by typing:
cd cfx_example
To complete testing, perform all the steps in Flow in a Static Mixer. This can be found in the Tutorials
& Training Materials section of the ANSYS Customer Portal.
Note
To speed up the process of testing, consider using the provided session files when
working with ANSYS CFX-Pre.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 35
Post-Installation Instructions
PATH=(/ansys_inc/v162/fluent/bin $path)
export PATH
After installing the ANSYS Fluent software, you will need to reset the default values in the ANSYS Fluent
launcher as follows:
Remove the FLUENT_INC setting from your .cshrc, .profile, or .bashrc file if you have
added it for previous versions. Verify that the environment variable is unset by typing:
printenv FLUENT_INC
4. Click Default.
5. Click Yes when asked if you want to discard the LAUNCHER history.
6. Click Cancel if you do not want to start Fluent at this time. The new defaults will have been saved.
Please refer to the ANSYS Fluent Quick Start Guide for more information.
Remove the FLUENT_INC setting from your .cshrc, .profile, or .bashrc file if you have added it
for previous versions. Verify that the environment variable is unset by typing:
printenv FLUENT_INC
1. Add the following paths to all users' login startup files (i.e., .cshrc or .login files).
/ansys_inc/v162/icemcfd/linux64_amd/bin
2. Add the following environment variable to all users' login startup files.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
36 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Localization
Add the following paths to all users' login startup files (i.e., .cshrc or .login files).
/ansys_inc/v162/autodyn/bin
3. If ANSYS BladeModeler is not the first license listed, then select it and click Move up as required to move
it to the top of the list. If ANSYS BladeModeler is not in the list, then you need to obtain an ANSYS
BladeModeler license.
4. Select ANSYS DesignModeler in the list and set its value to 0 (which means Don't Use). This step prevents
DesignModeler from using an ANSYS DesignModeler license when an ANSYS BladeModeler license is not
available.
You can inadvertently destroy your BladeEditor models by updating a project or otherwise processing
a Geometry cell, depending on your license preference settings. This problem can affect you if you have
any ANSYS DesignModeler licenses. To avoid this problem, configure the license preferences as described
above. For more details, please see Configuring the BladeModeler License in the ANSYS BladeEditor
documentation.
All products that are localized define the language via the languagesettings.txt file. In most
cases, you will not have to manually edit this file. If you do need to edit it manually, you can use one
of the following values:
ANSYS, Inc. applications will look for the languagesettings.txt file in the following locations, in
order:
1. $Home/.ansys/v162
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 37
Post-Installation Instructions
2. <install_dir>/ansys_inc/v162/commonfiles/language
ANSYS, Inc. licensing also looks for the languagesettings.txt in the licensing languages subdir-
ectories in order to display the ANSLIC_ADMIN utility and the ANSYS, Inc. Licensing Interconnect
message and log files in a different language.
Some products are not fully localized but offer only the messages in a translated version. See the fol-
lowing section for instructions on translated message file installation.
1. Create a language-named subdirectory (for example, fr for French) under the /docu directory:
mkdir /ansys_inc/v162/ansys/docu/fr
2. Copy the message files msgcat.162, msgidx.162, and msgfnm.162 into that subdirectory.
3. Access these files from the Language Selection option of the launcher or via the -l command line option:
ansys162 -l fr
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
38 of ANSYS, Inc. and its subsidiaries and affiliates.
Launching ANSYS, Inc. Products
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 39
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
40 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 6: Installing the ANSYS, Inc. Product Help Documentation
Only
Performing the ANSYS product help documentation installation places the entire help library onto your
computer.
If you downloaded the installation package, this file will reside in the directory where you untarred the
downloaded files.
If you are running from a DVD or USB, this file will reside in the top level of the DVD or USB.
2. From the options along the left side of the launcher click Install ANSYS Documentation Only.
3. Read the agreement, and if you agree to the terms and conditions, click I Agree. Click Next.
4. The directory where you want to install the ANSYS, Inc. help documentation is shown in the Install Direct-
ory field. You can install the help documentation into any directory you want, but you must have write
permissions to the directory you choose. The default is /ansys_inc. We recommend using the default dir-
ectory.
We strongly recommend that you also set the symbolic link /ansys_inc to the directory where the
ANSYS, Inc. product is installed. The symbolic link option is available only if you are installing as
root and is set by default. If you choose not to specify the symbolic link or are installing as a non-
root user, substitute the directory path where you installed the product for all subsequent occurrences
of/ansys_inc in this guide.
If you do not use the /ansys_inc symbolic link, you must install all releases into a common directory
to ensure license manager compatibility and availability among releases and products.
Click Next.
5. A summary screen appears listing your help documentation installation. You will also see an estimate of
the disk space required to install all of the selected components, and the disk space you have available.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 41
Installing the ANSYS, Inc. Product Help Documentation Only
6. When the help documentation installation has completed, click Exit. The product installation window re-
appears. You can close this window at this time.
Note
Alternatively, you can run the document installation by running the INSTALL.DOCONLY
installation file. This file is located in the linux directory on USB drives.
The ANSYS help documentation can be installed silently by running the INSTALL.DOCONLY installation
file with the silent flag. For more information, see Silent Mode Operations.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
42 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 7: Silent Mode Operations
ANSYS, Inc. supports silent mode operations, including installation, product configuration/unconfiguration,
and uninstall.
You can specify the following product flags. These flags are all valid for a silent install. However, because
of the way the products are packaged, not all of these flags may be valid for a silent configuration/un-
configuration, or uninstall.
Product Flags
Product product_flag
Mechanical APDL -mechapdl
ANSYS Customization Files -ansyscust
ANSYS Autodyn -autodyn
ANSYS LS-DYNA -lsdyna
ANSYS CFD-Post -cfdpost
ANSYS CFX -cfx
ANSYS TurboGrid -turbogrid
ANSYS Fluent -fluent
ANSYS Polyflow -polyflow
ANSYS Aqwa -aqwa
ANSYS ICEM CFD -icemcfd
Note: Installing any of the above products will install ANSYS Workbench.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 43
Silent Mode Operations
Caution
A silent license manager installation could shut down the ANSYS, Inc. License Manager, af-
fecting other users who are using that license server machine.
You can deploy an ANSYS, Inc. product installation in silent mode. The general form to run a silent
product installation, including the client licensing, is:
INSTALL -silent -install_dir path -product_flag
If no product flags from the list above are specified, all available products will be installed. To install
specific products, run the silent install with any combination of the product flags listed above (not all
products are available on all platforms). For example, to install only TurboGrid and Icepak, issue the
following command:
INSTALL -silent install_dir /ansys_inc/ -turbogrid -icepak
Additional command line arguments are available; please see the list below.
To install the ANSYS, Inc. License Manager on Linux systems that will act as license servers, you must
run the INSTALL.LM command:
INSTALL.LM -silent -install_dir path
The silent license manager installation is valid only for the default Licensing Configuration option "Run
the ANSYS Licensing Interconnect with FLEXlm." Please see the ANSYS, Inc. Licensing Guide for more in-
formation.
You can use the following arguments when running a silent installation. Note that some options are
available only for a silent license manager installation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
44 of ANSYS, Inc. and its subsidiaries and affiliates.
Silent Product and License Manager Installation
value. This flag can be used during a GUI installation as well. Valid only when
doing a license manager installation (INSTALL.LM).
-licserverinfo Specifies information to be used by the client for the license server. Valid only in
conjunction with a silent installation (INSTALL). The format is:
LI_port_number:FLEXlm_port_number:hostname
Example:
2325:1055:abc
LI_port_number:FLEXlm_port_number:hostname1,hostname2,host-
name3
Example:
2325:1055:abc,def,xyz
The default values for the Licensing Interconnect and FlexNet port numbers
(2325 and 1055, respectively) will be used if they are not specified. However,
you do need to include the colons.
Example:
::abc
or
::abc,def,xyz
Any messages will be written to the appropriate installation log files. Installation log files are located
in the installation directory: install.log contains installation messages, and install_liccon-
fig.log contains licensing installation messages. In rare circumstances with a silent licensing installation,
the licensing installation messages may not be written to the install_licconfig.log (for example,
if the silent licensing installation aborts); in these cases, you may find error messages in the .ansys_in-
stall_temp_licconfig_<user>_<index>.log file, located in $HOME/.ansys.
For more information on the silent license manager installation, see the ANSYS, Inc. Licensing Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 45
Silent Mode Operations
To run in silent mode, from each client machine, run the ProductConfig with the -silent option:
/ansys_inc/v162/ProductConfig.sh -silent
Use the -product_flag argument to specify which products should be configured. If you do not
specify one or more products, all products that have been installed will be configured. The valid
product_flags are:
Product product_flag
Mechanical APDL -mechapdl
ANSYS CFD-Post -cfdpost
ANSYS CFX -cfx
ANSYS TurboGrid -turbogrid
ANSYS Fluent -fluent
ANSYS Polyflow -polyflow
ANSYS Icepak -icepak
ANSYS ICEM CFD -icemcfd
ANSYS Remote Solve Manager Standalone Services -rsm
Copy the contents of each DVD to a folder on the machine's hard disk such that the 162-<number>.dvd
files of each DVD are located in the same directory. You can then proceed with the silent installation as de-
scribed earlier.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
46 of ANSYS, Inc. and its subsidiaries and affiliates.
Silent Media Installation
Place all of the media in separate drives (any combination of virtual ISO mounts or hardware drives) so that
they can be accessed simultaneously during the installation. Then run the silent installation as described
earlier, but include the additional -media_dir2 <path> and -media_dir3 <path> options as needed
for each drive:
INSTALL -silent -install_dir path -product_flag -media_dir2 <path -media_dir3 <path>
The installer uses the mount directory from which it was launched as the first media path; you need
to specify only the location of the subsequent DVD(s) using the -media_dir2 and -media_dir3
options shown in the example above.
The silent uninstall will automatically uninstall all products for this release and delete the v162 directory
and all subdirectories. You will not be prompted for confirmation.
To uninstall individual products, use the following product options in conjunction with the -silent
argument:
For example, to uninstall only TurboGrid and Icepak, issue the following command:
/ansys_inc/v162/ans_uninstall162 silent -turbogrid -icepak
You can also issue the -help option to see a list of valid arguments for a silent uninstall.
A record of the uninstall process will be written to ansys_inc/install.log. Any error messages
will be written to ansys_inc/install.err.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 47
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
48 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 8: Configuring CAD Products
The connection functionality of all supported CAD products is included with the ANSYS release media,
and all CAD functionality except NX is installed by default. To use the connection functionality, you
need to ensure that the product is properly licensed, and set any necessary environment variables or
other configuration as appropriate. See the manuals for the individual CAD products for information
about environment variables and other configuration requirements.
For complete information about the files you can import, see the Mechanical APDL ANSYS Connection
User's Guide.
Caution
Be sure to install Mechanical APDL and the connection functionality from the same release.
If you attempt to run the latest connection functionality on a machine that is running an
earlier release of Mechanical APDL, or vice versa, the connection may fail.
If you are running NX, some additional configuration may be required, especially if you chose to skip
configuring these products during the installation process. The following sections describe any post-
installation configuration procedures that are required and how to manually configure NX if you did
not configure NX during installation or if you are updating your CAD versions. These methods are all
described in the following sections.
CAD Selection
NX
CAD Configuration
An administrative user has the option to configure or unconfigure any selected CAD systems either for
the present user's environment or for all users, as indicated by the Configuration actions apply to
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 49
Configuring CAD Products
options. When the original installation was performed by a non-administrative user, an administrative
user will only be allowed to configure or unconfigure for all users. In this situation, NX configure and
unconfigure actions are skipped. Non-administrative users will only be allowed to configure for them-
selves. Any user-specific configuration settings take precedence over global configuration settings.
This document describes how to use the CAD Configuration Manager as a wizard on Linux systems,
beginning with the CAD Selection tab and using the Next button to progress through the configuration
process. You can also manually select each tab to progress through the configuration process; both
methods work the same. However, the applicable tabs will not be enabled until you choose the associated
product on the CAD Selection tab.
You can choose Help to view instructions on using the CAD Configuration Manager at any time. If
the help does not load into your default browser, set the BROWSER environment variable to the path
of your HTML viewer (such as Mozilla or Firefox) and restart the CAD Configuration Manager.
1. Run the following command to start the CAD Configuration Manager, substituting the full installation
path if different than /ansys_inc:
/ansys_inc/v162/commonfiles/CAD/bin/ansmono Ans.CadInt.CADConfigUtilityGUI.exe.
2. On the CAD Selection tab, choose the ANSYS products and the CAD products that you need to configure.
You must select at least one ANSYS product and at least one CAD product to enable the remaining func-
tionality.
b. The NX custom directory file is not applicable on Linux and can be ignored as it will be disabled.
c. Click Next.
b. When the configuration for all products is complete, log entries appear, listing those products that
were successfully configured and those that were not. Address any errors and reconfigure.
c. For more details, click the Display Configuration Log File button to see a detailed log file.
5. When all of your CAD products have been successfully configured, click Exit.
You can review the CAD Configuration Manager log file, CADConfigurationMgr.log, in /an-
sys_inc. If you do not have write permissions to the /ansys_inc directory, the log file will be
written to $TEMP. If you have not defined $TEMP, the log file is written to /tmp. When /tmp is not
accessible, this file will be written to the current working directory.
8.1.1. Unconfiguring
If you need to unconfigure any of your CAD products, follow the steps above, but choose Unconfigure
Selected CAD Interfaces on the CAD Configuration tab.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
50 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the CAD Configuration Manager
The command to run the CAD Configuration Manager in batch mode on Linux is:
/ansys_inc/v162/commonfiles/CAD/bin/ansmono Ans.CadInt.CADConfigurationUtility.exe
-arguments
Note
All arguments require a dash (-) before them in order to be properly recognized by the CAD
Configuration Manager. Arguments' values should not have a dash preceding them.
For example, you can configure the NX Geometry Interface to ANSYS Workbench from the command
line by using the following:
/ansys_inc/v162/commonfiles/CAD/bin/ansmono Ans.CadInt.CADConfigurationUtility.exe
-UG_CONFIG_WB -UGII_BASE_DIR "<pathtonx>"
Although the argument order does not matter, an argument value must immediately follow its argument.
8.1.3. NX Configuration
Running the CAD Configuration Manager for NX performs the following steps to activate the NX
reader:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 51
Configuring CAD Products
Registers the NX Associative Geometry Interface for ANSYS Workbench by copying the file UGNX#.Compon-
ent.XML from /ansys_inc/v162/aisol/CADIntegration/UG to either /ansys_inc/v162/com-
monfiles/registry/linx64/append when the configuration manager is in administrative mode or
to $HOME/.config/ANSYS/162/UserRegFiles_NNNN/append, when the CAD Configuration
Manager is run by a non-administrator. The CAD Configuration Manager ensures that only one version
of the file exists in the target location.
UGNX# is the NX version detected by the CAD Configuration Manager, and NNNN is a numeric
identifier appended to the UserRegFiles directory.
You must specify the environment variables UGII_BASE_DIR and UGII_ROOT_DIR. The UGII_BASE_DIR must
point to the install location supplied to the CAD Configuration Manager. The UGII_ROOT_DIR must point
to the /ugii or /bin subdirectory in the NX install location. The Workbench Associative Interface for NX
will not work without these two variables set properly, as these are required for proper startup of the CAD.
Prior to configuring a client of a network install, the client system must have its UGII_BASE_DIR point to
the same version of NX as designated on the server system. This must be done before running CAD Config-
uration Manager or the Product Configuration Tool. For more information, see Network Installation and
Product Configuration (p. 28).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
52 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 9: Uninstalling the Software
To uninstall a product, issue the following command:
/ansys_inc/v162/ans_uninstall162
Alternatively, if you are using the Mechanical APDL product, you can use the Uninstall option of the
ANS_ADMIN utility. To launch ANS_ADMIN, issue the following command:
/ansys_inc/v162/ansys/bin/ans_admin162
If you are not a superuser, you will see a warning message, and then the uninstall continues.
2. A list of products that are installed appears. Select those products you want to uninstall and click Continue.
Then click OK to confirm the list of products to be uninstalled.
In the case of a platform (file server) installation, the uninstall will remove the selected product(s) from
all of the Linux platforms.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 53
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
54 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 10: Troubleshooting
10.1. Installation Troubleshooting
This section lists problems and error messages that you may encounter while installing and/or running
ANSYS, Inc. products. After each situation description or error message is the user action required to
correct the problem.
You can also find answers to commonly-asked questions on our customer portal. After you log in to
the customer portal, select Knowledge Resources> Solutions.
For information on licensing-related errors, see the Troubleshooting section of the ANSYS, Inc. Licensing
Guide.
The client-related diagnostic information can be gathered by using the Client ANSLIC_ADMIN utility.
For more information, see, Gather Client Diagnostic Information.
The server-related diagnostic information can be gathered by using ANSYS License Management
Center or by using the standalone gatherdiagnostics script. For more information, see, Gathering
Diagnostic Information.
If the installation does not progress beyond the extraction of any single file during the file extraction phase,
you may have insufficient disk space in the temporary directory that the file extraction utility uses. Be aware
that some components require a lengthy extraction time; we recommend allowing up to 30 minutes for
these components to extract if you are running on a particularly old or slow system.
To resolve this problem, remove files from your $TEMP directory to free up disk space, or increase
the size of any disk quotas on your $TEMP directory.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 55
Troubleshooting
QT_IM_MODULE
XMODIFIERS
GTK_IM_MODULE
You should reset these environment variables when you are finished running the installation or using
ANSLIC_ADMIN. Do not permanently unset these environment variables as doing so could affect other
applications.
This message occurs if you have selected a platform for installation that does not match the files
you are trying to install (either from the installation DVD, USB or from downloaded installation files).
This error may appear during the ANSYS installation if you have entered the wrong DVD pathname.
Check Mounting the DVD Instructions for DVD Installations (Linux x64 Only) (p. 15) and enter the
correct pathname for your platform.
Licensing files currently installed for <platform> are more recent than those on the installation
media. The <platform> files will not be installed and will be deselected.
This message appears during an ANSYS, Inc. product installation if the installed license manager
files are newer than the ones being installed. You should always use the newest files. However, due
to system format changes or other unlikely scenarios, the date check could produce incorrect results.
To override the date check and force the installation to always install the files from the media, re-
gardless of the file dates, re-run the installation with the -nodatecheck option. We strongly re-
commend that you exercise caution when running the installation with the -nodatecheck option;
installing older license files can result in licensing errors and the inability to run ANSYS, Inc. products.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
56 of ANSYS, Inc. and its subsidiaries and affiliates.
Installation Troubleshooting - Mechanical APDL
Either the DISPLAY environment variable is not correct or the xhosts command was not properly
set. See the Mechanical APDL Basic Analysis Guide for specific graphics information.
***Error, ANSYS162_DIR environment variable is not set. This is a fatal error exiting.
This message indicates that the ANSYS162_DIR environment variable was not set where necessary
for licensing. This environment variable (which is set in the scripts that run ANSYS) should be set
to the release-specific installation directory.
You may encounter this or a similar message if you attempt to use ANSYS 16.2 with a different
version of MPI than is supported. See the Parallel Processing Guide for a complete list of supported
MPI versions.
10.2.1. Your batch jobs terminate when you log out of a session
On some systems, you may need to use the nohup option to allow batch jobs to continue running
after you log out of a session. If you are running via the Launcher, select Options> Use nohup To
Start Batch Runs With Output Sent to File Only. We do not recommend using this setting on systems
that automatically set nohup.
10.2.2. Mechanical APDL Documentation File for User Interface Error Messages
Missing or erroneous documentation files for user interface. Command ignored.
Verify that the documentation list file for the user interface exists in the /ansys_inc/v162/an-
sys/gui/en-us/UIDL subdirectory.
ls -l /ansys_inc/v162/ansys/gui/en-us/UIDL/menulist162.ans
Make sure that the pathnames in the menulist162.ans file are correct.
***Cannot create required <profile> file. Therefore, cannot write to profile information during
this launcher session.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 57
Troubleshooting
If you see this error, you cannot add or modify profile information during this launcher session.
Verify that you have write access to the directory and restart the launcher session. Typically, this
directory is C:\Documents and Settings\<user name>\Application Data\AN-
SYS\v162\launcher on Windows or ~/.ansys/v162/launcher on Linux.
In Procedure: fappnd
At Line: 72
Unit: 19
forrtl: severe (9): permission to access file denied, unit 19, file /build/v162/ansys/objs
Unable to open file /build/v162/ansys/objs/file.err for WRITE. Check directory and file permissions.
If you are running ANSYS Workbench on Linux and experience problems at startup or with the GUI or
graphics displaying correctly, and you are running in accelerated graphics mode, you may need to re-
launch ANSYS Workbench using the -oglmesa flag to activate software rendering:
runwb2 -oglmesa
If ANSYS Workbench detects that graphics problems are causing crashes, it will automatically switch to
software rendering. ANSYS Workbench also will use software rending mode by default when running
on a remote display, or on a local display if the hardware does not appear to be accelerated.
To revert to accelerated graphics mode, launch ANSYS Workbench using the -oglhw flag:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
58 of ANSYS, Inc. and its subsidiaries and affiliates.
Contacting Technical Support
runwb2 -oglhw
If your support is provided by ANSYS, Inc. directly, Technical Support can be accessed quickly and effi-
ciently from the ANSYS Customer Portal, which is available from the ANSYS Website (www.ansys.com)
under Support > Customer Portal. The direct URL is: support.ansys.com.
One of the many useful features of the Customer Portal is the Knowledge Resources Search, which can
be found on the Home page of the Customer Portal. To use this feature, enter relevant text (error
message, etc.) in the Knowledge Resources Search box and click the magnifying glass icon. These
Knowledge Resources provide solutions and guidance on how to resolve installation and licensing issues
quickly.
NORTH AMERICA
All ANSYS Products except Esterel, Apache and Reaction Design products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Toll-Free Telephone: 1.800.711.7199 (Please have your Customer or Contact ID ready.)
Support for University customers is provided only through the ANSYS Customer Portal.
GERMANY
ANSYS Mechanical Products
Telephone: +49 (0) 8092 7005-55 (CADFEM)
Email: support@cadfem.de
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
National Toll-Free Telephone: (Please have your Customer or Contact ID ready.)
German language: 0800 181 8499
English language: 0800 181 1565
Austria: 0800 297 835
Switzerland: 0800 546 318
International Telephone: (Please have your Customer or Contact ID ready.)
German language: +49 6151 152 9981
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 59
Troubleshooting
UNITED KINGDOM
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: Please have your Customer or Contact ID ready.
UK: 0800 048 0462
Republic of Ireland: 1800 065 6642
Outside UK: +44 1235 420130
Email: support-uk@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
JAPAN
Mechanical Products
Telephone: +81-3-5324-8333
Email:
Mechanical: japan-ansys-support@ansys.com
Fluids Products
Telephone: +81-3-5324-7305
Email:
Fluent: japan-fluent-support@ansys.com;
CFX: japan-cfx-support@ansys.com;
Polyflow: japan-polyflow-support@ansys.com;
Icepak
Telephone: +81-3-5324-7444
Email: japan-icepak-support@ansys.com
Licensing and Installation
Email: japan-license-support@ansys.com
INDIA
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +91 1 800 209 3475 (toll free) or +91 20 6654 3000 (toll) (Please have your Customer or
Contact ID ready.)
Support for University customers is provided only through the ANSYS Customer Portal.
FRANCE
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
60 of ANSYS, Inc. and its subsidiaries and affiliates.
Contacting Technical Support
Toll-Free Telephone: +33 (0) 800 919 225 Toll Number: +33 (0) 170 489 087 (Please have your Customer
or Contact ID ready.)
Email: support-france@ansys.com
BELGIUM
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +32 (0) 10 45 28 61
Email: support-belgium@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
SWEDEN
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +46 (0) 10 516 49 00
Email: support-sweden@ansys.com
ITALY
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +39 02 89013378
Email: support-italy@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 61
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
62 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 11: Applications Included with Each Product
The following table displays which ANSYS, Inc. applications are included with each of the product in-
stallation options.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 63
Applications Included with Each Product
1. Workbench includes the Workbench Framework, DesignModeler, DesignXplorer, and Remote Solve Manager.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
64 of ANSYS, Inc. and its subsidiaries and affiliates.
Installation Guide for Windows
The information in this guide applies to all ANSYS, Inc. products released on or after this date, until superseded
by a newer version of this guide. This guide replaces individual product installation guides from previous releases.
2015 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT, HFSS, AIM
and any and all ANSYS, Inc. brand, product, service and feature names, logos and slogans are registered trademarks
or trademarks of ANSYS, Inc. or its subsidiaries in the United States or other countries. ICEM CFD is a trademark
used by ANSYS, Inc. under license. CFX is a trademark of Sony Corporation in Japan. All other brand, product,
service and feature names or trademarks are the property of their respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
Windows Installation Guide
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
List of Tables
1.1. Supported Windows Platforms ................................................................................................................ 3
1.2. Supported Products by Platform ............................................................................................................. 3
1.3. CAD Support by Platform ........................................................................................................................ 4
2.1. Compiler Requirements for All Windows Versions .................................................................................. 13
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 1: Installation Prerequisites for Windows
This document describes the steps necessary to correctly install and configure all ANSYS, Inc. products
on Windows platforms for Release 16.2. These products include:
ANSYS Autodyn
ANSYS LS-DYNA
ANSYS TurboGrid
ANSYS Offshore
ANSYS Aqwa
Teamcenter
AutoCAD
ACIS
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Installation Prerequisites for Windows
CATIA, Version 4
CATIA, Version 5
CATIA, Version 6
Autodesk Inventor
JTOpen
NX
Parasolid
Creo Parametric
Solid Edge
SolidWorks
Note
ANSYS Workbench and ANSYS EKM Desktop are installed by default as product components
to most ANSYS, Inc. products. ANSYS Workbench is not installed as part of the products under
ANSYS Additional Tools, nor with the CFD-Post only option. ANSYS Workbench includes the
following applications:
DesignModeler
Design Exploration
Meshing
Fluent Meshing
FE Modeler
EKM Client
Because some of these applications can be run as standalone applications without ANSYS
Workbench, you will see some but not all of these listed separately as options when you
uninstall. In such cases, you will need to select those options in order to uninstall those
components.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
System Prerequisites
Important Notice
If you want to run multiple releases of ANSYS, Inc. software, you MUST install them chronologically (i.e.,
Release 16.1 followed by Release 16.2). If you install an earlier release after installing Release 16.2, you
will encounter licensing issues that may prevent you from running any products/releases. If you need
to install an earlier release after you have already installed Release 16.2, you MUST uninstall Release
16.2, then re-install the releases in order.
For detailed and current support information, see the Platform Support section of the ANSYS, Inc.
website (www.ansys.com).
Note
Supported Platforms for High Performance Computing Please see the discussions on Configuring
Distributed ANSYS and Configuring ANSYS CFX Parallel later in this guide for detailed information on
supported platforms for distributed computing.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
Installation Prerequisites for Windows
A = Mechanical APDL
W = ANSYS Workbench
I = ANSYS ICEM CFD standalone (some CAD systems may require the integrated ANSYS Work-
bench Reader)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
System Prerequisites
1. For ICEM CFD standalone, ACIS 18.0.1 is the supported version for all platforms.
4. MAPDL supports 5.1 by default, but 5.2 is also supported if the IOPTN command is used.
10. For ICEM CFD direct interface, Parasolid 24.0 is the supported version on all platforms.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
Installation Prerequisites for Windows
Note
View the latest supported CAD packages at ansys.com> Support> Platform Support>
Certified and Supported Computing Platforms.
Product installations also require an additional 500 MB of free disk space during an installation.
Memory Requirements You must have a minimum of 8 GB of memory to run product installations;
16 or 32 GB of memory is recommended.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
Additional Hardware and Software Requirements
.NET Framework 4.0 is native on Windows 8.1 and does not require any additional patches.
Microsoft Visual C++ 2008 Service Pack 1 Redistributable Package MFC Security Update
The machine(s) being used for the simulation must contain at least one supported nVIDIA GPU card or one
Intel Xeon Phi coprocessor. The following cards are supported:
For nVIDIA GPU cards, the driver version must be 333.11 or newer. For optimal performance on Windows,
the TCC (Tesla Compute Cluster) driver mode is recommended when using Tesla series GPU cards. Some
limitations exist when using this driver mode (e.g., no support for Windows XP). Check your GPU card doc-
umentation for more details on how to set this driver mode and the existing limitations.
For Intel Xeon Phi coprocessors, the driver version must be MPSS 3.4 or newer.
Note
On Windows, the use of Remote Desktop may disable the use of a GPU device. Launching
Mechanical APDL through the ANSYS Remote Solve Manager (RSM) when RSM is installed
as a service may also disable the use of a GPU. In these two scenarios, the GPU accelerator
capability cannot be used. Using the TCC (Tesla Compute Cluster) driver mode, if applicable,
can circumvent this restriction.
8 GB of RAM
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
Installation Prerequisites for Windows
Certified graphics card with the latest drivers, compatible with the supported operating systems, capable
of supporting 1024x768 High Color, and a 17-inch monitor compatible with this type of graphics card. We
recommend using certified graphics card from the Nvidia Quadro FX or AMD FirePro line.
Note
Use of Ultra High Definition (4K) graphics cards cause a number of cosmetic display
issues (including enlarged or reduced text and incorrect positioning of option labels).
These issues do not affect the functionality of the installation program.
ANSYS CFX products and ANSYS TurboGrid require at least 24-bit color and that antialiasing on your
graphics card be disabled. How you determine whether antialiasing is enabled and how to disable
the feature varies according to the graphics card you have. Please contact your system administrator
or refer to your system documentation for detailed instructions on changing antialiasing settings.
Note
Some combinations of graphics card type, operating system, and MPEG resolution fail to
play MPEGs properly. You may be able to get normal playback results simply by changing
the MPEG settings. Alternatively, you can upgrade your graphics card.
For laptop systems, ANSYS Workbench requires the latest graphics drivers.
Microsoft Mouse or a mouse compatible with the supported operating systems; ANSYS CFX-Pre and ANSYS
CFD-Post require a three-button mouse.
If you use a 3Dconnexion product, ensure that you have the latest version of the drivers installed.
Approximately twice as much swap space as memory. The amount of memory swap space on the system
may limit the size of the ANSYS model that can be created and/or solved.
TCP/IP for the license manager (see the ANSYS, Inc. Licensing Guide for more information on TCP/IP).
Although TCP/IP is included as part of the operating system, it may not be installed by default. When
TCP/IP is installed, it must be bound to a network adapter. On machines that are connected to an
internal network, TCP/IP must be bound to a network card such as an Ethernet adapter. The vast
majority of systems using TCP/IP will fall into this category. On machines that connect to the internet
or corporate intranet through a modem, TCP/IP can be bound to the Remote Access Service. Also,
the Autodial option of the Internet Options must be disabled so that the machine does not attempt
to connect to the Internet every time ANSYS is run. See the ANSYS, Inc. Licensing Guide for more in-
formation.
Microsoft Internet Explorer (IE) 9 or greater is recommended for proper operation of ANSYS Workbench.
Once the correct version of IE is installed, it does not have to be your default Internet browser. After install-
ation, simply run your preferred browser and reestablish it as the default.
PDF reader software is required to read the installation guides and other user documentation.
To access our help system videos, ANSYS recommends that you set Windows Media Player as your
default. Note--The default media player for Windows 8.1 is defined as Video; please change this setting
to Windows Media Player.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
Third-Party Software and other Security Considerations
To analyze larger models, use a recent NVidia Quadro or AMD FirePro card, including:
NVidia
NVidia ATI ATI Mobile
Mobile
Quadro FX Quadro FirePro FirePro
x700 x600M Vx800 Mx9xx
Quadro FX Quadro FirePro FirePro
x800 x700M Vx900 Mx000
Quadro
Quadro x000 FirePro Wx
x800M
Quadro
Quadro Kxxx FirePro Sx
x000M
Quadro
Quadro Kxxxx
kx000M
Quadro
kx100M
Note on Intel Graphics Cards: Use of integrated Intel graphics cards is not recommended. These cards
are typically found in lightweight laptops or notebooks, and are known to have OpenGL incompatibil-
ities resulting in display issues in AIM. Examples are Intel HD 3000 and 4000 series cards.
Note on Hybrid Graphics: If your graphics system supports two graphics chips, one integrated and
one dedicated (example is NVidia Optimus), please ensure that the dedicated graphics chip is used
when launching AIM. Instructions on how to do this can typically be found on graphics card vendor's
web site.
To use a 3Dconnexion product with the listed products, you must download and install the appropriate
Microsoft Windows driver for your version of Windows. Please refer to http://www.3dconnexion.com
for more information on using Space products and to download the appropriate drivers.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
Installation Prerequisites for Windows
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 2: Platform Details
2.1. User Account Control (UAC)
Windows 7 and Windows 8.1
Windows 7 and Windows 8.1 use a feature called User Account Control (UAC) to control privileges and
automatically reduce the potential of security breaches in the operation system. However, UAC limits
your accessibility to system areas and can cause unpredictable behavior in ANSYS, Inc. products.
ANSYS, Inc. requires that you have full administrative privileges when installing any software on Microsoft
Windows 7 or Windows 8.1. Non-administrative accounts do not usually have the permissions required
to access system areas that installation programs often need to modify. Full administrative privileges
means that you are running as administrator with UAC turned off, or you are running as administrator
with UAC turned on and Run as Administrator selected. Because of changes to the UAC functionality,
it is necessary that you right-click and select Run as Administrator from the context menu when in-
stalling to Windows 8.1.
UAC turned on and install with full administrative privileges (using Run as Administrator from the context
menu)
Note
If you are running with UAC on, even if you have administrative privileges, you will have
limited account control unless you specifically choose Run as Administrator.
UAC turned off and install with full administrative privileges (using Run as Administrator from the context
menu)
When installing ANSYS, Inc. products, we strongly recommend that you use the recommended options
above. If UAC is enabled, we recommend that you turn UAC off before installing ANSYS, Inc. products,
and then turn it back on when finished installing. You must be an administrative user in order to disable
UAC.
Follow the instructions for your operating system for disabling UAC.
Once you have installed your applications, you can enable UAC again.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
Platform Details
If you cannot disable UAC, you should perform the following functions:
For Windows 7:
Always run ANSLIC_ADMIN, the File Association utility, and the CAD Configuration Manager by selecting
the utility or application from the Start menu and right-mouse clicking and selecting Run as Administrator.
Set your Start menu shortcuts to always run as administrator with the following procedure (or similar):
2. From the Properties dialog box, click Advanced on the Shortcut tab.
4. Click OK.
Refer to your operating system documentation or visit www.microsoft.com for more instructions on
setting Run as Administrator at various levels within the operating system.
Always run ANSLIC_ADMIN, the File Association utility, and the CAD Configuration Manager by
selecting the utility or application from the Start menu and right-mouse clicking and selecting Run as
Administrator.
Set your Start menu shortcuts to always run as administrator with the following procedure (or similar):
1. Right-click the shortcut you wish to modify and select Open File Location from the options located
at the bottom of your screen.
2. Right-click the shortcut file that is displayed and click Properties from the menu.
3. From the Properties dialog box, click Advanced on the Shortcut tab.
5. Click OK.
You should install the ANSYS, Inc. License Manager using the same permissions as you used to install
the product.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
Compiler Requirements for Windows Systems
If you install both the product and the license manager with full administrative privileges, the product
and licensing installation and configuration will proceed as normal.
If you install as an administrative user with UAC turned on, you may encounter unpredictable behavior
with both the product and license manager installations and subsequent behavior. As an administrator,
you should choose to install and run applications with full administrative privileges to avoid any unpre-
dictable situations. We strongly recommend against running with UAC on and not selecting Run as
Administrator. These situations are described below.
1. If you have UAC turned on and you do not install (and run) with full administrative privileges, be aware
that files may be written to and read from the %localappdata%\VirtualStore\ location (in the case
of licensing, to %localappdata%\VirtualStore\Program Files\ANSYS Inc\Shared
Files\Licensing) instead of to the <os drive>.
In this situation, ANSLIC_ADMIN settings, such as Specify the License Server Machine, will indicate
that files are being written to and read from <os drive>\Program Files\ANSYS Inc\Shared
Files\Licensing. Log files may behave in the same way. However, when you view the an-
syslmd.ini file located in <os drive>\Program Files\ANSYS Inc\Shared
Files\Licensing, you will not see the ANSLIC_ADMIN settings you specified.
2. To ensure that files are correctly written to and read from <os drive>\Program Files\ANSYS
Inc\Shared Files\Licensing, you should always run with full administrative privileges by selecting
Run as Administrator.
3. If you are not running with full administrative privileges, you will not be able to use those ANSLIC_ADMIN
options that require administrative privileges, such as starting and stopping the license manager.
* Compilers are required only if you will be using User Programmable Features (UPF), User Defined
Functions (UDF), or other customization options.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
Platform Details
Installing the ANSYS Software for a Stand-alone Windows System (p. 15)
Installing the ANSYS Products and the License Manager on Different Windows Machines (p. 25)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 3: Installing the ANSYS Software for a Stand-alone Windows
System
This section includes the steps required for installing ANSYS, Inc. products and licensing configuration
on one Windows machine.
You can follow these instructions while actually installing the products and setting up the license
server. To do so, simply use the selections that are pertinent to you and insert your specific information
where noted.
An account on the ANSYS Customer Portal. If you do not have an account, you may register at https://sup-
port.ansys.com/portal/site/AnsysCustomerPortal to receive your own account.
Your license file from ANSYS, Inc., saved to a temporary directory. For more information, see Registering the
License Server (p. 23).
Open port numbers forFlexNet and ANSYS Licensing Interconnect. Defaults are 1055 and 2325, respectively.
To verify that these port numbers are available, open a command line and enter the following command:
netstat -a -p tcp
You will see a list of active ports. If 1055 and 2325 are listed, they are already in use and cannot be
used for ANSYS, Inc. licensing. In this case, you will need to specify different port numbers where in-
dicated later in this installation.
You should also verify that you are running on a supported platform. ANSYS, Inc. supports 64-bit systems
running Windows 7 and Windows 8.1.
Verify that you have sufficient disk space to download, uncompress, and install the products you will
be installing.
If you have any problems with--or questions about--the installation process, log a Service Request on
the ANSYS Customer Portal to have a Systems Support Specialist assist you.
Product Download/DVD Instructions: This set of instructions describes the download and extraction process.
Product Installation with Client Licensing: This set of instructions describes the product installation, including
the client licensing portion.
License Manager Installation: This set of instructions describes the license manager installation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
Installing the ANSYS Software for a Stand-alone Windows System
Post-Installation Procedures for All Products: This is a set of instructions that describes any configuration
steps that may be required for the various products.
For this installation, both the product and the license manager will be installed on the same machine.
You must complete both the client licensing portion and the license manager installation in order to run
ANSYS, Inc. products.
Depending on the product/platform combination(s) you choose, you may need to download multiple
files.
Step 1 of the ANSYS Download Center Select Full Products page is displayed.
Primary Packages: Individual full packages for the primary ANSYS products.
7. To download Add-On Packages, Tools or Academic Packages, click the + to the right of the appropriate
product group title to display the download options and download as required.
8. After all downloads have been completed, uncompress each package using standard uncompression
utilities for your specific platform. We strongly recommend that you extract the files into new, temporary
directories.
9. Begin the product installation as described in Installing ANSYS, Inc. Products (p. 17).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
contained on the DVD and select Run as administrator. Continue with the steps described in Installing
ANSYS, Inc. Products (p. 17).
You will be prompted to change DVDs during the installation. Please make sure you have all installation
DVDs before beginning the installation.
Note
ANSYS requires users to install all products by using the right-click option Run as ad-
ministrator.
Note
You must also install the ANSYS, Inc. License Manager on at least one server machine in order
to run ANSYS, Inc. products. See ANSYS License Manager Installation (p. 21) for license
manager installation instructions.
1. Save all data and close all Windows applications before continuing.
2. If you downloaded the installation files or if you are installing from a DVD or USB with autorun disabled,
browse to the location of the setup.exe file. Right-click the setup.exe file and select Run as admin-
istrator.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
Installing the ANSYS Software for a Stand-alone Windows System
From the options on the left side of the launcher you can install ANSYS products, ANSYS EKM
Server, MPI for ANSYS Parallel Processing, and the ANSYS License Manager. You can access the in-
stallation guide for the ANSYS EKM Server from the Downloads page on the Customer Portal. The
MPI for ANSYS Parallel Processing installation steps are displayed when you click the Install MPI
for ANSYS Parallel Processing link.
The ANSYS, Inc. Quick Start Installation Guide, ANSYS, Inc. Quick Start Licensing Guide, System Re-
quirements Guide and complete Installation Help Guide can be accessed through the options located
along the bottom of the launcher.
3. Select the language you want to use from the drop-down menu in the upper right corner. English is the
default.
5. Read the agreement, and if you agree to the terms and conditions, select I Agree. Click Next.
6. The directory where you want to install the ANSYS, Inc. products is shown in the Install Directory field.
You can install the products into any directory you want, but you must have write permissions to the
directory you choose. The default is C:\Program Files\ANSYS Inc. We recommend using the default
directory.
Note
You must install all ANSYS, Inc. products into the same location. Installing products
into different locations can cause product components to fail. If you choose an install
directory via the Browse feature, the installation will automatically append \ANSYS
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
Inc\ to the chosen directory. The installation path can have a maximum of 100
characters, except on AUTODYN, which has a maximum of 40 characters.
Leave the Associate file extensions with ANSYS products checkbox marked. This allows you to
double-click files from Windows Explorer to launch the various products.
Choose Disable ANSYS RSS Feed to disable automatic internet feeds to ANSYS, Inc. products.
Click Next.
7. If this is a first time installation, you are prompted to enter your license server specification. If you already
have an existing license server specification file, you will not see this window and proceed directly to the
next step.
Enter your ANSYS Licensing Interconnect port number and your ANSYS FlexNet port number. Defaults
are provided and will work in most cases. You may need to check with your IT department to
confirm that the default port numbers are valid or to get different port numbers if necessary.
Click Next.
8. All products available in the installation package(s) you downloaded are listed.
The installation program attempts to query your license server to pre-select your installation options.
If the query is successful, the following message is displayed:
Your installation options were pre-selected based upon information from your license server.
If the installation program was unable to query your license server, this message is not displayed
and the default installation options are selected.
You can select or deselect any combination of products. ANSYS Workbench is automatically installed
with most ANSYS, Inc. products; there is no individual product selection for ANSYS Workbench.
If you select AutoCAD, Catia V5, Inventor, NX, Creo Parametric, Solid Edge, or SolidWorks, you will
have additional installation steps. Please see Specifying CAD Configurations (p. 20).
By default, the Install Documentation option is enabled (checked). When enabled, help document-
ation is included as part of the installation process for all products selected. No help documentation
is included with the installation if this box is disabled (unchecked).
You will also see an estimate of the disk space required to install all of the selected components,
and the disk space you have available. The actual amount of disk space required may be less, but
if you choose to run the installation with insufficient disk space available, we strongly recommend
that you review the log files at the end of the installation to verify that all products were installed
correctly. Installation log files are written to the installation directory.
Note
On a first time installation, if you chose to install any ANSYS Geometry Interfaces, en-
sure that you have also selected at least one ANSYS, Inc. product as part of the in-
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
Installing the ANSYS Software for a Stand-alone Windows System
The dates on the licensing files being installed are compared to any that may already exist on your
machine. (This may take a few moments.)
9. A summary of the selected installation data appears. Review the information carefully, and if correct, click
Next to continue the installation.
10. The installation progress screen displays a status bar towards the bottom of the installation window. This
status bar tracks the percentage of packages that have been installed on your computer. Depending on
the number of products you have selected, the installation time required could be lengthy. You will not
be able to interrupt the installation process. Please be patient while the installation completes.
Note
Clicking the View Details Progress Log button opens a second window that displays
the name of each product package as it is uncompressed and installed.
The installation program will first check your system to determine if you have the necessary pre-
requisites. If the prerequisites are not already on your system, the prerequisites will be installed
automatically. You may be asked to run the necessary files (such as the .NET exe), or to reboot your
machine, depending on your existing machine configuration. If you are asked, you will need to
reboot in order to complete the prerequisite installation successfully.
11. The product installation window reappears with a message noting that the installation is complete. A
Launch Survey Upon Exiting option is included here. Clicking Exit while the Launch Survey Upon Ex-
iting is enabled causes your default browser to open, displaying the product survey. Disabling (un-
checking) the Launch Survey Upon Exiting option and then clicking Exit skips the survey.
Note
The ANSYS, Inc. Installation Launcher appears. For this stand-alone installation, you must complete
the License Manager installation (next) to run ANSYS, Inc. products.
1. If you selected Creo Parametric, you will have to choose which Creo Parametric product to configure. You
can choose the Reader (non-associative), Workbench Associative Interface (requires that the CAD product
be installed), or skip and configure later (using the CAD Configuration Manager).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
2. If you choose the Workbench Associative Interface, you may need to specify the Creo Parametric language,
the Creo Parametric command, and the full Creo Parametric installation path (C:\Program
Files\PTC\Creo 1.0\Parametric by default) for an existing Creo Parametric installation. Click
Next.
NX
1. If you selected NX, you will have to choose which NX product to configure. You can choose the Reader
(non-associative), Workbench Associative Interface (requires that the CAD product be installed), or skip
and configure later (using the CAD Configuration Manager).
2. If you choose the Workbench Associative Interface and the UGII environment variables were not set, you
may need to specify the NX installation path for an existing NX installation. If you are an administrative
user, a file required to load the NX plug-in is placed in the administrative user's Application Data folder
by default, which may not be accessible by other, non-administrative users. To allow non-administrative
users to run, you will need to define the environment variable UGII_CUSTOM_DIRECTORY_FILE prior
to installation and specify a location where other users have read access. Alternatively, you can run the
CAD Configuration Manager after the installation and provide an updated location for the NX Custom
Directory File Path under the NX tab.
3. If you selected the ANSYS ICEM CFD NX Interface product but not the NX Geometry Interface product on
the product selection screen, you may need to specify the NX installation path or choose to skip config-
uring NX and use the CAD Configuration Manager to configure later.
CATIA v5
If you selected CATIA v5 and any product that includes ANSYS Workbench, you will be required to select
the appropriate CAD reader/plugin for ANSYS Workbench. You can choose to configure the Reader,
CADNexus CAPRI CAE Gateway, or skip and configure later (using the CAD Configuration Manager).
If you selected Inventor and/or SolidWorks as one of your CAD products, you will have to choose which
Inventor and/or SolidWorks product to configure. You can choose the Reader (non-associative), Workbench
Associative Interface (requires that the CAD product be installed), or skip and configure later (using the
CAD Configuration Manager).
If you have not yet installed these programs, or do not know the requested information, you can choose
to skip these configuration steps. If you skip these steps, you will need to manually configure these
CAD interfaces using the CAD Configuration Manager before you can successfully import models into
Mechanical APDL, ANSYS Workbench, or ICEM CFD. You can access the CAD Configuration Manager
in Windows 7 (Start > All Programs > ANSYS 16.2 > Utilities > CAD Configuration Manager 16.2)
and in Windows 8.1 (Right-click the Start Screen> All apps> ANSYS 16.2 > CAD Configuration
Manager 16.2). See Configuring CAD Products (p. 53) for more information on using the CAD Config-
uration Manager.
1. If the Installation Launcher is not open, right-click the setup.exe file and select Run as administrator.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
Installing the ANSYS Software for a Stand-alone Windows System
If you downloaded only the license manager installation, right-click setupLM.exe and select Run
as administrator.
4. You will be notified that the license manager, if running, will be shut down. Click OK.
5. The License Agreement screen appears. Read the license agreement, and if you agree, click I Agree to
accept the terms and click Next. You must select I Agree to continue with the installation.
6. Specify the installation directory and click Next to continue.. You can accept the default or specify an al-
ternate path and the directory name where the license manager is to be installed. The installation directory
is set to <OS_Drive>\Program Files\ANSYS Inc by default. You must have administrative priv-
ileges for the directory you specify. In addition, the directory:
Note
You are unable to change the installation directory for a computer that currently contains
an instance of the ANSYS, Inc. License Manager or ANSYS Electromagnetics License
Manager. To change the installation directory location, you must first uninstall any pre-
vious versions of both products.
The ANSYS, Inc. License Manager is the only component available and is selected to be installed.
The amount of disk space required and the disk space available appear at the bottom of the window.
Be sure that you have sufficient space before continuing.
8. A summary of the selected installation data appears. Review the information carefully, and if correct, click
Next to continue the installation.
The ANSYS License Manager is now being installed and configured on your system. After the License
Manager installation has been completed, the Launch License Management Center upon exiting
option is included on the screen. The ANSYS License Management Center is a browser-based
user interface that centralizes many of the ANSYS product licensing administrative functions. If you
do not want to launch the License Management Center, uncheck the Launch License Management
Center upon exiting option.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
10. When the license manager installation is complete, click Exit. A new Start Menu item named ANSYS, Inc.
License Manager will be created automatically. It will include selections for the License Management
Center, the ANSYS, Inc. Licensing Guide, the FlexNet License Administration Guide and the ANSLIC_ADMIN
utility.
1. Use the Register License Server Machine Information option of the ANSLIC_ADMIN server utility to re-
gister license server information on each license server.
2. Select OK and Create File to save this information to a file named licserver.info by default.
3. Return the resulting licserver.info file to your ANSYS sales representative. ANSYS, Inc. or your sales
representative will then supply you with your license keys. This file is located in Program Files\ANSYS
Inc\Shared Files\Licensing\licserver.info by default.
4. Use the Run the License Wizard option of the ANSLIC_ADMIN server utility to install your license file and
start the license manager.
After completing the installation process, please refer to Post-Installation Instructions (p. 37)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 4: Installing the ANSYS Products and the License Manager
on Different Windows Machines
This section describes installing ANSYS, Inc. products on one Windows machine and installing the ANSYS,
Inc. License Manager on a different Windows machine that will act as a license server.
You can follow these instructions while actually installing the products and setting up the license
server. To do so, simply use the selections that are pertinent to you and insert your specific information
where noted.
An account on the ANSYS Customer Portal. If you do not have an account, you may register at https://sup-
port.ansys.com/portal/site/AnsysCustomerPortal to receive your own account.
Your license file from ANSYS, Inc., saved to a temporary directory. For more information, see Registering the
License Server (p. 35).
Open port numbers for FlexNet and ANSYS Licensing Interconnect on your license server machine. Defaults
are 1055 and 2325, respectively. To verify that these port numbers are available, open a command line on
the server machine and enter the following command:
netstat -a -p tcp
You will see a list of active ports. If 1055 and 2325 are listed, they are already in use and cannot be
used for ANSYS, Inc. licensing. In this case, you will need to specify different port numbers where in-
dicated later in this tutorial.
You should also verify that you are running on a supported platform. ANSYS, Inc. supports 64-bit systems
running Windows 7, and Windows 8.1.
Verify that you have sufficient disk space to download, uncompress, and install the products you will
be installing.
For network installations, the same UNC paths or mapped drive letters must be used on the server and
all client computers. Failure to use matching UNC paths or mapped letter drives can cause server
communication issues or loss of product functionality.
If you have any problems with--or questions about--the installation process, log a Service Request on
the ANSYS Customer Portal to have a Systems Support Specialist assist you.
Product Download/DVD Instructions: This set of instructions describes the download and extraction process.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
Installing the ANSYS Products and the License Manager on Different Windows Ma-
chines
Product Installation with Client Licensing: This set of instructions describes the product installation, including
the client licensing portion.
License Manager Installation: This set of instructions describes the license manager installation.
Post-Installation Procedures for All Products: This is a set of instructions that describes any configuration
steps that may be required for the various products.
For this procedure, the product and the license manager will be installed on separate Windows machines.
You must complete both the client licensing portion and the license manager installation in order to run
ANSYS, Inc. products.
Depending on the product/platform combination(s) you choose, you may need to download multiple
files.
Step 1 of the ANSYS Download Center Select Full Products page is displayed.
Primary Packages: Individual full packages for the primary ANSYS products.
7. To download Add-On Packages, Tools or Academic Packages, click the + to the right of the appropriate
product group title to display the download options and download as required.
8. After all downloads have been completed, uncompress each package using standard uncompression
utilities for your specific platform. We strongly recommend that you extract the files into new, temporary
directories.
9. Begin the product installation as described in Installing ANSYS, Inc. Products (p. 27)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
If you are installing from media, you will be prompted to change DVDs during the installation. Please
make sure you have all installation DVDs before beginning the installation.
Note
ANSYS requires users to install all products by using the right-click option Run as ad-
ministrator.
Note
You must also install the ANSYS, Inc. License Manager on at least one server machine in order
to run ANSYS, Inc. products. See ANSYS License Manager Installation (p. 34) for license
manager installation instructions.
1. Save all data and close all Windows applications before continuing.
2. If you downloaded the installation files or if you are installing from a DVD or USB with autorun disabled,
navigate to the location of the setup.exe file. Right-click the setup.exe file and select Run as admin-
istrator.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
Installing the ANSYS Products and the License Manager on Different Windows Ma-
chines
From the options on the left side of the launcher you can install ANSYS products, ANSYS EKM
Server, MPI for ANSYS Parallel Processing, and the ANSYS License Manager. You can access the in-
stallation guide for the ANSYS EKM Server from the Downloads page on the Customer Portal. The
MPI for ANSYS Parallel Processing installation steps are displayed when you click the Install MPI
for ANSYS Parallel Processing link.
The ANSYS, Inc. Quick Start Installation Guide, ANSYS, Inc. Quick Start Licensing Guide, System Re-
quirements Guide and complete Installation Help Guide can be accessed through the options located
along the bottom of the launcher.
3. Select the language you want to use from the drop-down menu in the upper right corner. English is the
default.
5. Read the agreement, and if you agree to the terms and conditions, click I Agree. Click Next.
6. The directory where you want to install the ANSYS, Inc. products is shown in the Install Directory field.
You can install the products into any directory you want, but you must have write permissions to the
directory you choose. The default is C:\Program Files\ANSYS Inc. We recommend using the default
directory.
Note
You must install all ANSYS, Inc. products into the same location. Installing products into
different locations can cause product components to fail. If you choose an install directory
via the Browse feature, the installation will automatically append \ANSYS Inc\ to the
chosen directory. The installation path can have a maximum of 100 characters, except
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
Leave the Associate file extensions with ANSYS products checkbox marked. This allows you to
double-click files from Windows Explorer to launch the various products.
If you specify a network location as the installation directory, you should select the Add .NET security
exceptions on the above install directory option. This option allows the .NET binaries that are located
under the \ANSYS Inc directory on the shared machine to be run from the network. To understand
the implications of this security exception for .NET, please contact your system administrator or see
Microsofts website http://msdn.microsoft.com/en-us/library/7c9c2y1w(v=vs.80).aspx.
Choose Disable ANSYS RSS Feed to disable automatic internet feeds to ANSYS, Inc. products.
Used with network installations, this option allows the .NET binaries that are located under the \ANSYS
Inc directory on the shared machine to be run from the network.
Click Next.
7. If this is a first time installation, you are prompted to enter your license server specification. If you already
have an existing license server specification file, you will not see this window and proceed directly to the
next step.
Enter your ANSYS Licensing Interconnect port number and your ANSYS FlexNet port number. Defaults
are provided and will work in most cases. You may need to check with your IT department to
confirm that the default port numbers are valid or to get different port numbers if necessary.
Click Next.
8. All products available in the installation package(s) you downloaded are listed. The installation program
attempts to query your license server to pre-select your installation options. If the query is successful, the
following message is displayed:
Your installation options were pre-selected based upon information from your license server.
If the installation program was unable to query your license server, this message is not displayed
and the default installation options are selected.
You can select or deselect any combination of products. ANSYS Workbench is automatically installed
with most ANSYS, Inc. products; there is no individual product selection for ANSYS Workbench.
If you select AutoCAD, Catia V5, Inventor, NX, Creo Parametric, Solid Edge, or SolidWorks, you will
have additional installation steps. Please see Specifying CAD Configurations (p. 33).
By default, the Install Documentation option is enabled (checked). When enabled, help document-
ation is included as part of the installation process for all products selected. No help documentation
is included with the installation if this box is disabled (unchecked).
You will also see an estimate of the disk space required to install all of the selected components,
and the disk space you have available. The actual amount of disk space required may be less, but
if you choose to run the installation with insufficient disk space available, we strongly recommend
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 29
Installing the ANSYS Products and the License Manager on Different Windows Ma-
chines
that you review the log files at the end of the installation to verify that all products were installed
correctly. Installation log files are written to the installation directory.
Note
On a first time installation, if you chose to install any ANSYS Geometry Interfaces, en-
sure that you have also selected at least one ANSYS, Inc. product as part of the in-
stallation. Installing an ANSYS Geometry Interface without an underlying ANSYS,
Inc. product on a first time installation may cause installation errors.
The dates on the licensing files being installed are compared to any that may already exist on your
machine. (This may take a few moments.)
9. A summary of the selected installation data appears. Review the information carefully, and if correct, click
Next to continue the installation.
10. The installation progress screen displays a status bar towards the bottom of the installation window. This
status bar tracks the percentage of packages that have been installed on your computer. Depending on
the number of products you have selected, the installation time required could be lengthy. You will not
be able to interrupt the installation process. Please be patient while the installation completes.
Note
Clicking the View Details Progress Log button opens a second window that displays
the name of each product package as it is uncompressed and installed.
The installation program will first check your system to determine if you have the necessary pre-
requisites. If the prerequisites are not already on your system, the prerequisites will be installed
automatically. You may be asked to run the necessary files (such as the .NET exe), or to reboot your
machine, depending on your existing machine configuration. If you are asked, you will need to
reboot in order to complete the prerequisite installation successfully.
11. The product installation window reappears with a message noting that the installation is complete. A
Launch Survey Upon Exiting option is included here. Clicking Exit while the Launch Survey Upon Ex-
iting is enabled causes your default browser to open, displaying the product survey. Disabling (un-
checking) the Launch Survey Upon Exiting option and then clicking Exit skips the survey.
Note
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
30 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
1. Install the product(s) to be shared in a location that all clients can access. Install all platforms that this
machine will host as described in Product Installation with Client Licensing (p. 27).
You must share the entire \ANSYS Inc directory, not just the \v162 directory. If mapping a
drive to the shared location, it must be mapped to the \ANSYS Inc folder.
3. A configuration status screen appears. This screen displays the required prerequisite installation process.
Once the process is complete, click Exit. The Product Configuration Manager remains open.
4. On each Windows client, update the .NET security settings. By default, the .NET 3.5 Framework prevents
applications from being run over a network. In order to install over a network, each Windows client that
accesses the shared directory requires a modification to its security settings. This modification allows the
.NET binaries that are located under the \ANSYS Inc directory on the shared machine to be run from
the network. To make this modification from the Product Configuration Manager, select Add .NET security
exception for ANSYS, Inc. products. You must have administrative privileges to modify the security
policy.
To understand the implications of this security exception for .NET, please contact your system ad-
ministrator or see Microsofts website http://msdn.microsoft.com/en-us/library/
7c9c2y1w(v=vs.80).aspx.
Alternatively, you can allow network execution manually rather than using the Add .NET security
exception for ANSYS, Inc. products option of the Product Configuration Manager. The Add .NET
security exception for ANSYS, Inc. products option runs the Caspol utility, which is located under
the .NET Framework installation, in C:\Windows\Microsoft.NET\Framework64\v2.0.50727
for a 64-bit machine. You can run this utility manually in a command prompt window to open full
trust to files on the shared drive.
where x is the mapped drive or UNC path where the product is installed, and CodeGroup is the
appropriate Caspol permissions level. We recommend a CodeGroup setting of 1.2. If that setting
does not work or is not appropriate for your environment, please see the Caspol documentation
available from Microsoft or contact your system administrator.
You must install Caspol as an administrative user. If running this from the command line in Windows
7 or Windows 8.1, you must start the command prompt as Administrator, or the command will fail.
5. If you are sharing the Mechanical APDL product, edit the tlbrlist162.ans file, located in
\v162\ansys\gui\en-us\toolbars on the Windows file server. The file should read as follows:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 31
Installing the ANSYS Products and the License Manager on Different Windows Ma-
chines
\\fileservermachine\ANSYS Inc\v162\ansys\gui\en-us\toolbars\ANSYSSTANDARD.TLB
\\fileservermachine\ANSYS Inc\v162\ansys\gui\en-us\toolbars\ANSYSABBR.TLB
\\fileservermachine\ANSYS Inc\v162\ansys\gui\en-us\toolbars\ANSYSGRAPHICAL.TLB
6. For all types of network installations, from each client Windows machine, you will need to run Product-
Config.exe. If the Product Configuration Manager has been closed, please reopen it as described above.
Note
All operations and error messages that are encountered while using the product configuration (or
unconfiguration) option are written to the productConfig.txt file in the %TEMP% directory of
the client machine. No log files are written to the machine that is hosting ProductConfig.exe.
Note
ProductConfig.exe can also be run in batch mode using the -silent' flag, which may
be useful for automating configuration for multiple systems or across a Microsoft
Windows HPC cluster. For more information see Silent Mode Operations (p. 45).
11. The CAD Configuration Manager opens. Run this utility for all of the CAD products you need to configure.
See Using the CAD Configuration Manager for detailed instructions on running this utility, or select Help
from the menu bar in the CAD Configuration Manager.
12. When the configuration is completed, you will see shortcuts to each product in Windows 7 under Start
> All Programs > ANSYS 16.2 and in Windows 8.1 under All apps> ANSYS 16.2.
Unconfigure To unconfigure products that have previously been shared, use the following procedure:
1. From each client machine, in Windows 7, select Start > All Programs > ANSYS 16.2 > Utilities> Product
Configuration 16.2 and in Windows 8.1, right-click the Start Screen> All apps> ANSYS 16.2> Product
Configuration 16.2.
3. Select the products you want to unconfigure. Click Unconfigure. When unconfiguring products, be aware
that WB/Common should be unconfigured last, after all other products are unconfigured. If you are un-
configuring some but not all products, do NOT unconfigure WB/Common, or your remaining products
will not run correctly.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
32 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
If you choose to unconfigure standalone CFD-Post without unconfiguring the other products, you will
not be able to proceed with the unconfigure. You will need to revise your selections before continuing.
If you choose to unconfigure all of the other products that include CFD-Post but you do not select CFD-
Post, then CFD-Post will not be unconfigured.
4. The user interface billboard displays the status of each product as it is unconfigured. The shortcuts to
each product are now removed.
1. If you selected Creo Parametric, you will have to choose which Creo Parametric product to configure. You
can choose the Reader (non-associative), Workbench Associative Interface (requires that the CAD product
be installed), or skip and configure later (using the CAD Configuration Manager).
2. If you choose the Workbench Associative Interface, you may need to specify the Creo Parametric language,
the Creo Parametric command, and the full Creo Parametric installation path (C:\Program
Files\PTC\Creo 1.0\Parametric by default) for an existing Creo Parametric installation. Click
Next.
NX
1. If you selected NX, you will have to choose which NX product to configure. You can choose the Reader
(non-associative), Workbench Associative Interface (requires that the CAD product be installed), or skip
and configure later (using the CAD Configuration Manager).
2. If you choose the Workbench Associative Interface and the UGII environment variables were not set, you
may need to specify the NX installation path for an existing NX installation. If you are an administrative
user, a file required to load the NX plug-in is placed in the administrative user's Application Data folder
by default, which may not be accessible by other, non-administrative users. To allow non-administrative
users to run, you will need to define the environment variable UGII_CUSTOM_DIRECTORY_FILE prior
to installation and specify a location where other users have read access. Alternatively, you can run the
CAD Configuration Manager after the installation and provide an updated location for the NX Custom
Directory File Path under the NX tab.
3. If you selected the ANSYS ICEM CFD NX Interface product but not the NX Geometry Interface product on
the product selection screen, you may need to specify the NX installation path or choose to skip config-
uring NX and use the CAD Configuration Manager to configure later.
CATIA v5
If you selected CATIA v5 and any product that includes ANSYS Workbench, you will be required to select
the appropriate CAD reader/plugin for ANSYS Workbench. You can choose to configure the Reader,
CADNexus CAPRI CAE Gateway, or skip and configure later (using the CAD Configuration Manager).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 33
Installing the ANSYS Products and the License Manager on Different Windows Ma-
chines
SolidWorks and Autodesk Inventor
If you selected Inventor and/or SolidWorks as one of your CAD products, you will have to choose which
Inventor and/or SolidWorks product to configure. You can choose the Reader (non-associative), Workbench
Associative Interface (requires that the CAD product be installed), or skip and configure later (using the
CAD Configuration Manager).
If you have not yet installed these programs, or do not know the requested information, you can choose
to skip these configuration steps. If you skip these steps, you will need to manually configure these
CAD interfaces using the CAD Configuration Manager before you can successfully import models into
Mechanical APDL, ANSYS Workbench, or ICEM CFD. You can access the CAD Configuration Manager
in Windows 7 (Start > All Programs > ANSYS 16.2 > Utilities > CAD Configuration Manager 16.2)
and in Windows 8.1 (Right-click the Start Screen> All apps> ANSYS 16.2 > CAD Configuration
Manager 16.2). See Configuring CAD Products (p. 53) for more information on using the CAD Config-
uration Manager.
1. On the server machine, navigate to the directory where the installation packages reside. Right-click the
setup.exe file and select Run as administrator. The ANSYS, Inc. Installation Launcher appears. Click
Install ANSYS License Manager.
2. You will see a warning stating that if the license manager is currently running, it will be shut down. You
may safely ignore this message and click OK.
3. The license agreement appears. Read the agreement, and if you agree to the terms and conditions, click
I Agree. Click Next.
4. The directory where the license manager will be installed is shown in the Install Directory field. Accept
the default directory and click Next.
Note
You are unable to change the installation directory for a computer that currently contains
an instance of the ANSYS, Inc. License Manager or ANSYS Electromagnetics License
Manager. To change the installation directory location, you must first uninstall any pre-
vious versions of both products.
5. The ANSYS, Inc. License Manager is selected as the only product available to install. As with the product
installation, the required and available disk space numbers are shown. Click Next.
6. A summary screen appears that lists the products to be installed. Because this is a license manager install-
ation, the ANSYS, Inc. License Manager is the only product listed.
After the License Manager installation has been completed, the Launch License Management
Center upon exiting option is included on the screen. The ANSYS License Management Center
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
34 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
is a browser-based user interface that centralizes many of the ANSYS product licensing administrative
functions. If you do not want to launch the License Management Center, uncheck the Launch Li-
cense Management Center upon exiting option.
9. From the machine on which the products were installed, choose Start> Programs> ANSYS 16.2>
<product> to launch the ANSYS, Inc. products that you have installed.
2. Click the Get System Hostid Information option to display your system ID code(s).
3. Select the system ID you wish to use and click SAVE TO FILE.
4. Forward this text file to your ANSYS sales representative so that a license file can be created for you.
5. Add your license files though the ANSYS License Management Center. For these steps, see Adding a License
with the ANSYS License Management Center.
After completing the installation process, please refer to Post-Installation Instructions (p. 37)
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 35
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
36 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 5: Post-Installation Instructions
The following post-installation procedures apply to all ANSYS, Inc. products. Individual products may
have additional post-installation procedures; please refer to the following sections for each product:
5.1. Post-Installation Procedures for Mechanical APDL and ANSYS Workbench Products
5.2. Launching ANSYS, Inc. Products
5.3. Running the ANS_ADMIN Utility for Mechanical APDL /ANSYS Workbench Products
5.4. Product Localization
Note
If the installation program reported any errors, please review the installation error file (in-
stall.err) located in the ANSYS Inc directory. Contact your ANSYS Support representative if
you have any questions.
It may also be necessary to establish some system settings, including path names and environment
variables. See your operating system documentation for specific instructions on setting paths and en-
vironment variables.
1. Set the following environment variables based on the behavior you want.
The ANSYSLIC_DIR environment variable sets the location of the ANSYS licensing directory hierarchy.
The default value is c:\Program Files\ANSYS Inc\Shared Files\Licensing. You probably
will not need to reset this variable, unless you change the location of the licensing files.
Windows 7: Right-click Computer and choose Properties. Click Advanced System Settings, and
click Environment Variables. Click New. Type the name in the Variable Name field and the desired
setting in the Variable Value field. Click OK on all dialog boxes.
Windows 8.1: From the Start Screen, right-click, select All apps and then click the File Explorer
icon. On the left side of the File Explorer, right-click Computer and choose Properties. Click Ad-
vanced System Settings, and click Environment Variables. Click New. Type the name in the
Variable Name field and the desired setting in the Variable Value field. Click OK on all dialog boxes.
If you have any command prompts or console windows open when you set or reset environment
variables, those windows need to be closed and restarted in order to pick up the new settings.
2. Set the home directory. To set a home directory in Windows, you need to set a HOMEDRIVE environment
variable to the desired drive letter (including the colon) and a HOMEPATH environment variable to the
desired path. For example:
HOMEDRIVE=C:
HOMEPATH=\Users\Mine
3. Set the license manager to start automatically at boot time. For platform-specific instructions, see License
Manager Automatic Startup Instructions in the ANSYS, Inc. Licensing Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 37
Post-Installation Instructions
4. Designate server(s) for license checkout and establish necessary user privileges (recommended but not
required). For information on these tasks, see Post-Installation Instructions for the License Manager in the
ANSYS, Inc. Licensing Guide.
6. Verify the product installation by selecting each product from the Start menu to verify that they each
start and run correctly. You must be pointing to a valid license server machine before you can verify the
installation.
7. If you chose not to set file associations during the installation, you may want to run the File Association
utility now to configure the ANSYS file types. Administrative privileges are required to run this utility
For Windows 7, select Start> All Programs> ANSYS 16.2> Utilities> File Association 16.2 and
for Windows 8.1, right-click the Start Screen> All apps> ANSYS 16.2> File Association 16.2.
For network installations, run the File Association utility on each client computer.
You can also run the File Association utility in silent mode:
<install_dir>\v162\commonfiles\tools\<platform>\fileassoc.exe -silent
You can see help on the fileassoc.exe by issuing -help. File associations are as follows:
Quality Assurance Services: If you require verification of Mechanical APDL, the Mechanical Application,
Fluent, or CFX, ANSYS, Inc. offers Quality Assurance services. If you are interested in this service, go to
http://www.ansys.com/Support/Quality+Assurance/Quality+Services or call the ANSYS, Inc. Corporate
Quality Group at (724) 746-3304.
Set the following environment variables based on the behavior you want. Set the environment variables
following the conventions of your operating system. Not all of these are required for all integrated ANSYS
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
38 of ANSYS, Inc. and its subsidiaries and affiliates.
Post-Installation Procedures for Mechanical APDL and ANSYS Workbench Products
Workbench products (such as ANSYS Autodyn), but setting them correctly for ANSYS Workbench will in
no way hinder the performance of the other products.
The ANSYS162_DIR environment variable sets the location of the ANSYS directory hierarchy. The default
value is c:\Program Files\ANSYS Inc\V162\ANSYS. You probably will not need to reset this
variable, unless you change the location of the installed files.
ANSYS162_PRODUCT - set this to the correct product variable to run Mechanical APDL to start with
the correct Mechanical APDL product without specifying the -p command modifier each time.
ANS_CONSEC - set this to YES to disable Mechanical APDL dialog boxes and allow multiple jobs to run
consecutively without waiting for user input. Settings for ANS_CONSEC are:
ANSYS_LOCK - set to ON (default) to create file locks to prevent users from opening a new job with
the same name and in the same directory as the current job.
ANSYS162_MAT161 - set this environment variable to 1 to enable use of the LS-DYNA *MAT_COMPOS-
ITE_MSC material (requires an LS-DYNA MAT_161 license).
ANSYS162_MAT162 - set this environment variable to 1 to enable use of the LS-DYNA *MAT_COMPOS-
ITE_DMG_MSG material (requires an LS-DYNA MAT_162 license).
LSTC_LICENSE - This is an LS-DYNA environment variable that controls which license manager is used
by the LS-DYNA executable. It is set to ANSYS during installation; changing this environment variable
will prevent ANSYS LS-DYNA from using your ANSYS licenses when running the executable.
1. In Windows 7, select Start> All Programs> ANSYS 16.2> Fluid Dynamics> CFX 16.2. In Windows 8.1,
right-click the Start Screen> All apps> ANSYS 16.2> CFX 16.2.
2. In the Working Directory field of the Launcher, type the path to the examples directory, which by default
is: C:\Program Files\ANSYS Inc\v162\CFX\examples
4. Select File > Load Results. The Load Results File window opens.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 39
Post-Installation Instructions
6. Select Session > Play Session. The Play Session File window opens. Select StaticMixerPost.cse and
click Open.
The mixer changes orientation, displays a plane colored by temperature, hides the plane, then
loads a vector plot of temperature located on the plane.
7. Select File > Close and close the case without saving.
If any of the installation verification steps fails, contact your ANSYS Support representative.
1. Verify that the FLUENT_INC environment variable is not set. From the Control Panel, select System and
click the Advanced tab. Click Environment Variables. Find and delete the FLUENT_INC variable.
2. In Windows 7, select Start> All Programs> ANSYS 16.2> Fluid Dynamics> Fluent 16.2. In Windows 8.1,
right-click theStart Screen> All apps> ANSYS 16.2> FLUENT 16.2.
3. Click Default.
4. Click Yes when asked if you want to discard the LAUNCHER history.
5. Click Cancel if you do not want to start Fluent at this time. The new defaults will have been saved.
Please refer to the ANSYS Fluent Quick Start Guide for more information.
From the Control Panel, select System and click the Advanced tab. Click Environment Variables. Find and
delete the FLUENT_INC variable.
BladeEditor In order to use BladeEditor, you must set the Geometry license preference to ANSYS
BladeModeler as follows:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
40 of ANSYS, Inc. and its subsidiaries and affiliates.
Product Localization
3. If ANSYS BladeModeler is not the first license listed, then select it and click Move up as required to move
it to the top of the list. If ANSYS BladeModeler is not in the list, then you need to obtain an ANSYS
BladeModeler license.
4. Select ANSYS DesignModeler in the list and set its value to 0 (which means Don't Use). This step prevents
DesignModeler from using an ANSYS DesignModeler license when an ANSYS BladeModeler license is not
available.
FEMGV For ANSYS Aqwa customers, FEMGV is also available as a separate, standalone installation,
available via media or the ANSYS Customer Download Center.
Windows 7: Start> All Programs> ANSYS 16.2> Mechanical APDL Product Launcher 16.2.
Windows 8.1: Start Screen> All apps> ANSYS 16.2> Mechanical APDL Product Launcher 16.2.
To run the ANS_ADMIN utility from Windows 7, choose Start> All Programs> ANSYS 16.2> Utilities>
ANS_ADMIN 16.2. To run the ANS_ADMIN utility from Windows 8.1, right-click the Start Screen> All
apps> ANSYS 16.2> ANS_ADMIN 16.2.
All products that are localized define the language via the languagesettings.txt file. In most
cases, you will not have to manually edit this file. If you do need to edit it manually, you can use one
of the following values:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 41
Post-Installation Instructions
ANSYS, Inc. applications will look for the languagesettings.txt file in the following locations, in
order:
1. %appdata%\ANSYS\v162
2. <install_dir>\ANSYS Inc\v162\commonfiles\Language
ANSYS, Inc. licensing also looks for the languagesettings.txt in the licensing languages subdir-
ectories in order to display the server ANSLIC_ADMIN utility and the ANSYS, Inc. Licensing Interconnect
message and log files in a different language.
Some products are not fully localized but offer only the messages in a translated version. See the fol-
lowing section for instructions on translated message file installation.
1. Create an appropriately named subdirectory to hold the message files. For example, if your local language
is French, create a directory in the following location:
<os drive>\Program Files\ANSYS Inc\V162\ANSYS\docu\fr
2. Copy the message files (msgcat.162, msgidx.162, and msgfnm.162) into the newly created subdir-
ectory.
3. Access these message files by using the -l command line option. For example:
ansys162 -l fr
Or, when you are running Mechanical APDL from the Mechanical APDL launcher, choose the Lan-
guage Selection option and then pick the desired language.
You must create a newly translated message file for each release of Mechanical APDL because error
messages may occur in a different order for each release.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
42 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 6: Installing the ANSYS, Inc. Product Help Documentation
Only
Performing the ANSYS product help documentation installation places the entire help library onto your
computer.
2. If you downloaded the installation files or if you are installing from a DVD/USB with autorun disabled,
navigate to the location of the setup.exe file. Right-click the setup.exe file and select Run as administrator.
3. From the options along the left side of the launcher click Install ANSYS Documentation Only.
4. Read the agreement, and if you agree to the terms and conditions, click I Agree. Click Next.
5. The directory where you want to install the ANSYS, Inc. help documentation is shown in the Install Direct-
ory field. You can install the products into any directory you want, but you must have write permissions
to the directory you choose. The default is C:\Program Files\ANSYS Inc. We recommend using the default
directory.
Click Next.
6. A summary screen appears listing your help documentation installation. You will also see an estimate of
the disk space required to install all of the selected components, and the disk space you have available.
7. When the help documentation installation has completed, click Exit. The product installation window re-
appears. You can close this window at this time.
Note
Alternatively, you can run the document installation by running the SetupDocOnly.exe
installation file. This file is located in the windows directory on USB drives.
The ANSYS help documentation can be installed silently by running the SetupDocOnly.exe installation
file with the silent flag. For more information, see Silent Mode Operations.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 43
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
44 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 7: Silent Mode Operations
7.1. Installing ANSYS, Inc. Products
This section explains how to install ANSYS, Inc. products.
ANSYS, Inc. requires that you have full administrative privileges when installing any software on Microsoft
Windows 7 or Windows 8.1. Non-administrative accounts do not usually have the permissions required
to access system areas that installation programs often need to modify. Full administrative privileges
means that you are running as administrator with UAC turned off, or you are running as administrator
with UAC turned on and Run as Administrator selected. Because of changes to the UAC functionality,
it is necessary that you right-click and select Run as Administrator from the context menu when in-
stalling to Windows 8.1.
Windows 7 and Windows 8.1 use a feature called User Account Control (UAC) to control privileges and
automatically reduce the potential of security breaches in the operation system. However, UAC limits
your accessibility to system areas and can cause unpredictable behavior in ANSYS, Inc. products, as
noted below.
You can specify the following product flags. These flags are all valid for a silent install. However, because
of the way the products are packaged, not all of these flags may be valid for a silent configuration/un-
configuration or uninstall. Not all products are available on all platforms.
For silent mode operations, if you do not specify any product arguments, all available products will be
installed, configured, or uninstalled.
Product Flags
Product product_flag
Mechanical APDL -mechapdl
ANSYS Customization Files -ansyscust
ANSYS Autodyn -autodyn
ANSYS LS-DYNA -lsdyna
ANSYS CFD-Post -cfdpost
ANSYS CFX -cfx
ANSYS TurboGrid -turbogrid
ANSYS Fluent -fluent
ANSYS Polyflow -polyflow
ANSYS Aqwa -aqwa
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 45
Silent Mode Operations
Product product_flag
ANSYS ICEM CFD -icemcfd
ANSYS AIM -aim
Note: Installing any of the above products will install ANSYS Workbench.
Caution
A silent license manager installation could shut down the ANSYS, Inc. License Manager, af-
fecting other users who are using that license server machine.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
46 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
You can deploy an ANSYS, Inc. product installation in silent mode. The general form to run a silent
product installation, including the client licensing, from the Start>Run menu is:
setup.exe -silent -product_flag
Note
The above form will install the products specified (see the list of product_flags above). Additional
command line arguments are available; please see the list below.
For example, to install TurboGrid and Icepak to the default installation directory, issue the following
command:
setup.exe -silent -install_dir C:\Program Files\ANSYS Inc -turbogrid -icepak
To install the ANSYS License Manager on Windows systems that will act as license servers, you must
run the setupLM.exe:
setupLM.exe -silent
The silent license manager installation is valid only for the default Licensing Configuration option "Run
the ANSYS Licensing Interconnect with FLEXlm." Please see Installing the ANSYS License Manager of
the ANSYS, Inc. Licensing Guide for more information.
If you are installing the license manager to a non-default installation directory, you can use the silent
installation method, but only for the initial installation. To change the license manager installation dir-
ectory for future installations, you will need to uninstall the license manager before reinstalling to a
different directory.
You can use the following arguments when running a silent installation:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 47
Silent Mode Operations
exception for .NET, please contact your system administrator or see Microsofts
website http://msdn.microsoft.com/en-us/library/7c9c2y1w(v=vs.80).aspx.
-help Displays a list of valid arguments for a silent installation.
-licfilepath Specifies the location of the license file to install. If the path is not specified or if
"path" the path is the same as the existing license file, the license file will not be installed.
Valid only when doing a silent license manager installation (setupLM.exe).
-setliclang Specifies a language to use for the server ANSLIC_ADMIN utility and the ANSYS,
language Inc. Licensing Interconnect log file. Use the language directory name in the
language subdirectory of the licensing directory (en-us, fr, de, etc.) as the
language value. This flag can be used during a GUI installation as well. Valid
only when doing a license manager installation (setupLM.exe).
-licserverinfo Specifies information to be used by the client for the license server. Valid only in
conjunction with a silent installation (setup.exe). The format is:
Example:
2325:1055:abc
Example:
2325:1055:abc,def,xyz
The default values for the Licensing Interconnect and FlexNet port numbers
(2325 and 1055, respectively) will be used if they are not specified. However,
you do need to include the colons. In a three-server environment, you also
need to enclose the values in quotes (Windows only).
Example:
::abc
or
::abc,def,xyz
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
48 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
The silent installation process will automatically close certain applications, possibly resulting in lost data.
You should always close all programs before starting a silent install. A silent install will first install any
necessary prerequisites that are not already on your system and then continue with the installation.
You must have administrative privileges to install prerequisites; if not, the silent install will exit and
write a message to the log file.
Installation log files are located in the installation directory: install.log contains installation messages,
and install_licconfig.log contains licensing installation messages. In rare circumstances with
a silent licensing installation, the licensing installation messages may not be written to the install_lic-
config.log (for example, if the silent licensing installation aborts); in these cases, you may find error
messages in the .ansys_install_temp_licconfig_<user>_<index>.log file, located in
%TEMP%.
For more information on the silent license manager installation, see Installing the ANSYS License Manager
of the ANSYS, Inc. Licensing Guide.
NX: Verify that your UGII environment variables are set, and the configuration will pick them up automatically.
Creo Parametric: Verify that the following environment variables are set:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 49
Silent Mode Operations
From each client machine, run the ProductConfig.exe -silent with the following options:
-config, -unconfig, -prereqs, -caspol, and -product_flag. These options are described
below.
-config/-unconfig -- Use with the -silent option to indicate that products should be configured/un-
configured.
-prereqs -- Required to install the necessary prerequisites on your system. Prerequisites must be installed
once on each machine.
-caspol -- Required to modify the necessary .NET security settings to allow the product to run across the
network. This option needs to be run once on each machine.
-product_flag -- Use to specify which products should be configured; see the above list of
product_flags. If you do not specify one or more products, all products that have been installed will be
configured.
Use the -help option for a list of commands available for use with ProductConfig.exe.
All operations and error messages that are encountered while using the silent product configuration/un-
configuration option are written to the productConfig.txt file in the %TEMP% directory of the client
machine. No log files are written to the machine that is hosting ProductConfig.exe.
Copy the contents of each DVD to a folder on the machine's hard disk such that the 162-<number>.dvd
files of each DVD are located in the same directory. You can then proceed with the silent installation as de-
scribed earlier.
Place all of the media in separate drives (any combination of virtual ISO mounts or hardware drives) so that
they can be accessed simultaneously during the installation. Then run the silent installation as described
earlier, but include the additional -media_dir2 <path> option for each drive:
setup.exe -silent -product_flag -media_dir2 <path>
The installer uses the mount directory from which it was launched as the first media path; you need
to specify only the location of the subsequent DVD(s) using the -media_dir2 option shown in the
example above.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
50 of ANSYS, Inc. and its subsidiaries and affiliates.
Installing ANSYS, Inc. Products
The silent uninstall will unconfigure and remove all products and remove the entire \v162 directory,
including any user files or subdirectories that you have added to the \v162 directory.
Because of the way ANSYS, Inc. products are packaged, not all of the product_flags shown above
are valid. To uninstall individual products, use the following product options in conjunction with the
-silent argument:
For example, to uninstall only TurboGrid and Icepak, issue the following command:
C:\> <installation path>\v162\Uninstall.exe -silent -turbogrid -icepak
You can also issue the -help option to see a list of valid arguments for a silent uninstall.
Note that CFD-Post is also installed with CFX; however, you do not need to uninstall CFX to uninstall
the standalone version of CFD-Post, and uninstalling the standalone version of CFD-Post will not remove
the CFD-Post capability from CFX.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 51
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
52 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 8: Configuring CAD Products
The connection, geometry interface, and other CAD functionality for all supported CAD products is in-
cluded with the ANSYS release media. Select the CAD systems you want to install during the installation
process. If you choose not to install CAD systems during the installation, you can install them at a later
date.
For complete information about the files you can import and the platforms supported by the connection
capability, see the ANSYS Connection User's Guide. For more information about geometry interface in-
formation in ANSYS Workbench, see the topics Attach to Active CAD Geometry and Import External
Geometry File in the ANSYS DesignModeler help.
Caution
Be sure to install Mechanical APDL and the connection functionality from the same release.
If you attempt to run the latest connection functionality on a machine that is running an
earlier release of Mechanical APDL, or vice versa, the connection may fail.
The connection for Creo Parametric requires you to run Mechanical APDL, Creo Parametric and the
connection for Creo Parametric on the same machine. The connection for NX requires you to run
Mechanical APDL, NX, and the connection for NX on the same machine. The connections for CATIA,
SAT, and Parasolid do not require any additional CAD installation.
CAD Selection
Creo Parametric
NX
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 53
Configuring CAD Products
CAD Configuration
This document describes how to use the CAD Configuration Manager as a wizard, beginning with the
CAD Selection tab and using the Next button to progress through the configuration process. You can
also manually select each tab to progress through the configuration process; both methods work the
same. However, the applicable tabs will not be enabled until you choose the associated product on the
CAD Selection tab.
1. From Windows 7, click Start > All Programs > ANSYS 16.2 > Utilities > CAD Configuration Manager
16.2. From Windows 8.1, right-click the Start Screen> All apps> ANSYS 16.2> CAD Configuration
Manager 16.2.
2. On the CAD Selection tab, choose the CAD products that you need to configure. Click Next.
3. If you did not select any CAD interfaces the necessary prerequisites will be registered, enabling Geometry
(DesignModeler). You must run the CAD Configuration Manager as an administrative user for some
CAD registrations to take place. Select the CAD Configuration tab and click Configure Selected CAD
Interfaces to register the prerequisites.
4. If you selected Creo Parametric as one of your CAD products, you will have to choose which Creo Para-
metric product to configure:
a. The Reader option specifies the non-associative source and doesn't require a Creo Parametric install-
ation. (This reader does not support CAD associativity or parameters.)
b. The Workbench Associative Plug-In option requires Creo Parametric to be installed. When you
choose this option, the Creo Parametric tab opens.
i. Enter or browse to the Creo Parametric installation location (for example, C:\Program
Files\PTC\Creo 2.0\Parametric).
ii. Enter or browse to the Creo Parametric start command (for example, C:\Program
Files\PTC\Creo 2.0\Parametric\bin\parametric.bat). Include the complete
path if entering the command manually.
Note
When ANSYS Workbench is installed by an administrative user, the Creo Parametric plug-
in will load for all users of the designated CAD install. However, when multiple Creo
Parametric installations are present on the system, the plug-in should only be configured
for a single installation of Creo Parametric; otherwise unconfiguring the plug-in will
cause load problems for all other installations of the CAD.
5. If you selected NX as one of your CAD products, you will have to choose which NX product to configure:
a. The Reader option specifies the non-associative source and doesn't require an NX installation. (This
reader does not support CAD associativity or parameters.)
b. The Workbench Associative Plug-In option requires NX to be installed. When you choose this option,
the NX tab opens.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
54 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the CAD Configuration Manager
ii. Enter or browse to the NX custom directory file path (for example, C:\Documents and
Settings\UserName\Application Data\ANSYS\v162\Unigraphics).
Note
If you are installing as an administrator, this file path will be defined in your
administrator's user space by default and non-administrative users will not be
able to run. Use this setting to specify a new location for the custom directory
file path that is accessible by all users.
6. If you selected Inventor and/or SolidWorks as one of your CAD products, you will have to choose which
Inventor and/or SolidWorks product to configure:
a. The Reader option specifies the non-associative source and doesn't require an Inventor or SolidWorks
installation. (This reader does not support CAD associativity or parameters.)
7. If SpaceClaim Engineer is installed, you will have to choose to configure the ANSYS Workbench Plug-
In for either SpaceClaim Direct Modeler or SpaceClaim Engineer. Otherwise you are limited to config-
uring the SpaceClaim Direct Modeler Plug-In.
8. If you selected Teamcenter as one of your CAD products, the Teamcenter tab opens:
c. Choose Next.
9. If you selected Catia V5 as one of your CAD products, you will have the option to choose which CATIA V5
product to configure.
a. Select the Reader option to configure the CATIA V5 standalone reader that does not require an in-
stallation of the CATIA V5 CAD program. (This reader does not support CAD associativity or parameters.)
b. Select the CADNexus/CAPRI CAE Gateway option to configure the CATIA V5 associative reader that
does require an installation of the CATIA V5 CAD program and the CADNexus/CAPRI CAE Gateway
(this geometry interface does support CAD associativity and parameter modifications).
c. Click Next.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 55
Configuring CAD Products
b. When the configuration for all products is complete, log entries appear, listing those products that
were successfully configured and those that were not. Address any errors and reconfigure.
c. For more details, click the Display Configuration Log File button to see a detailed log file.
11. When all of your CAD products have been successfully configured, click Exit.
You can review the CAD Configuration Manager log file, CADConfigurationMgr.log, in \ANSYS
Inc.
Important
If you change your source from reader to associative plug-in or vice-versa (Creo Parametric,
NX, SolidWorks, Autodesk Inventor, or Catia V5), you must first unconfigure the existing
source and then configure using the new source.
8.1.1. Unconfiguring
If you need to unconfigure any of your CAD products, follow the steps above, but choose Unconfigure
Selected CAD Interfaces on the CAD Configuration tab.
The command to run the CAD Configuration Manager in batch mode on Windows is:
"<installpath>\commonfiles\CAD\bin\winx64\Ans.CadInt.CADConfigurationUtility.exe"
-arguments
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
56 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the CAD Configuration Manager
Note
All arguments require a dash (-) before them in order to be properly recognized by the CAD
Configuration Manager. Arguments' values should not have a dash preceding them.
For example, you can configure Creo Parametric and SolidWorks Geometry Interfaces to ANSYS Workbench
from the command line by using the following:
"<installpath>\commonfiles\CAD\bin\winx64\Ans.CadInt.CADConfigurationUtility.exe"
-SW_CONFIG -PE_CONFIG_WB -PROELOADPOINT "C:\Program Files\PTC\Creo 2.0\Parametric"
-PROE_START_CMD "C:\Program Files\PTC\Creo 2.0\Parametric\bin\parametric.bat"
where installpath is the same as the value of environment variable %AWP_ROOT162%, platform
is the value of environment variable %ANSYS_SYSDIR%, and Creo Parametric is installed to C:\Program
Files\PTC\Creo 2.0\Parametric.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 57
Configuring CAD Products
Although the argument order does not matter, an argument value must immediately follow its argument.
Prior to running the CAD Configuration Manager from a network location, the product configuration
tool must be executed. This process will result in the client system being configured to match the
geometry interface selections on the server. Products requiring additional information such as interfaces
to Creo Parametric, NX and Teamcenter may fail to configure. This can be remedied either by manually
running CAD Configuration Manager following Product Configuration, or by setting appropriate envir-
onment variables prior to execution of Product Configuration such as UGII_CUSTOM_DIRECTORY_FILE,
PROE_START_CMD150 and TC_ROOT. TC_ROOT can be set to the path of your Teamcenter installation.
Further details regarding environment variables pertaining to Creo Parameteric and NX are offered in
the interface specific help sections below. For more information on using the Product Configuration
manager, please see Network Server and Product Configuration (p. 31).
For loading associative geometry interfaces into their respective CAD environments, when the Workbench
installation is referenced from a network location:
A local administrators configuration changes will set up associative CAD interfaces to load into the CAD
environment of all local users, when that scope is selected (applicable to AutoCAD, Inventor, SolidWorks,
Solid Edge, Creo Elements/Direct and NX).
The associative geometry interface for Creo Parametric will load into the CAD environment of all users when
the CAD installation is writable for that administrative user. Otherwise, it will load only into the CAD envir-
onment of the administrator who is currently logged in, and each additional user must be configured indi-
vidually.
CAD Readers for JT, Creo Parametric, Inventor, NX and Solidworks may not fully unconfigure on a client
of a network installation, even when this action is attempted by a client's administrator. An administrative
user on the server must execute an unconfigure action, using CAD Configuration Manager, in order for
these interfaces to be fully deactivated on the client.
8.1.4. Uninstalling
Warning
Do not proceed with an uninstall for CAD-specific unconfigure actions or you will leave some
ANSYS Workbench products unusable.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
58 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the CAD Configuration Manager
Sets the environment variable PROE_START_CMD162 to the file used to launch Creo Parametric (for example
C:\Program Files\PTC\Creo 2.0\Parametric\bin\parametric.bat).
For administrative installations, adds the ANSYS 16.2 entry to the config.pro file located in
<creo_path>\text. An example for Creo Parametric would be:
PROTKDAT C:\Program Files\PTC\Creo 2.0\Common Files\M100\text
Updates the WBPlugInPE.dat file referenced in the config.pro file, so that it contains information for
loading the WorkBench Plug-In and the ANSYS Connection product.
When Workbench is installed on a network location and the local administrator has write permissions to
<creo_path>\text, a version-specific WBPlugInPE162.dat file will be created and placed in that
folder. However, when <creo_path>\text is unwriteable, both the config.pro and the WBPlugIn-
PE162.dat will be placed in either %HOME% or %HOMEDRIVE%%HOMEPATH%.
If you do not have write access to your ANSYS Workbench installation, you may encounter the following
error when attempting to import Creo Parametric models without an active CAD session:
No write access, please choose another startup directory for trail file
creation.
To prevent this issue, add the following line to your config.pro file:
trail_dir $TEMP
WBPlugInPE.dat File Contents The WBPlugInPE.dat file should look like this example:
NAME WB162PluginProWF
EXEC_FILE E:\Program Files\ANSYS Inc\V162\AISOL\CADIntegration\ProE\
winx64\WBPlugInPECOM.dll
TEXT_DIR E:\Program Files\ANSYS Inc\V162\AISOL\CADIntegration\ProE\
ProEPages\Language\<locale>
STARTUP dll
delay_start FALSE
allow_stop TRUE
unicode_encoding FALSE
REVISION ProEWildfire
END
NAME ac4pro162dll
exec_path E:\Program Files\ANSYS Inc\V162\ANSYS\ac4\bin\pro\winx64\ac4pro.exe
text_path E:\Program Files\ANSYS Inc\V162\ANSYS\ac4\data\pro\text
STARTUP dll
delay_start FALSE
allow_stop TRUE
unicode_encoding FALSE
unicode_encoding FALSE
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 59
Configuring CAD Products
revision 24.0
end
Note
When configuring the plug-in to run with Wildfire 5.0, the reference to WBPlugInPECOM.dll
will instead be DSPlugInPEWF5COM.dll and ac4pro.exe should be ac4pro_wf5.exe.
<locale> should be "en-us" for English, "de" for German, "fr" for French, or "ja" for Japanese.
Do not delete any of these lines. If you modify this file, do NOT enter a carriage return after the END
line. The file may be customized with other information. If these lines are deleted, or if the WBPlugIn-
PE.dat file is not present in any of the directories in the search path, Creo Parametric will not load
ANSYS-related CAD interfaces. You should typically never have to edit these files for path information
contained within them. Paths are determined by environment variable settings, which are set automat-
ically during installation. If you encounter problems when attempting to run Creo Parametric, use the
CAD Configuration Manager to reconfigure rather than attempting to edit files directly.
Following an update of an existing Creo Parametric 2.0 or 3.0 installation to a different maintenance
release (for example upgrading from datecode F000 to M010), the ANSYS Workbench Associative Plug-
In will no longer be configured. To reactivate your plug-in, follow the steps described in Using the CAD
Configuration Manager (p. 53). This situation does not apply to Pro/ENGINEER Wildfire 5.0, or Creo
Elements/Pro 5.0.
In order for CAD Configuration Manager to successfully perform configuration of the Creo Parametric
Associative Geometry Interface it is required that the Windows Operating System's decimal separator
be the same symbol when running configuration as it was when the original Creo Parametric installation
was performed.
Note
If the ANSGeom menu in Creo Parametric does not appear correctly, copy the con-
fig.anscon.162 file into your working directory and restart Creo Parametric.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
60 of ANSYS, Inc. and its subsidiaries and affiliates.
Using the CAD Configuration Manager
The config.pro file resides in <path-to-proe>\text for any Pro/ENGINEER Wildfire release and
<path-to-creo-parametric>\..\Common Files\<Creo Ship Code>\text for Creo Parametric.
The Creo Ship Code is a three digit number preceded by a single letter. The ship code is specified in
the Creo Parametric installation log, which can be found in <path-to-creo-parametric>\unin-
stall\instlog.txt for version 1.0, or in <path-to-creo-parametric>\bin\pim\xml\creo-
base.xml for version 2.0. For version 2.0, in the cases that the crebase.xml file is missing, the ship code
can be determined by looking in the Windows Registry using regedit. That value is located in either
HKLM\Software\PTC\Creo Parametric\2.0\Shipcode or SOFTWARE\Wow6432Node\PTC\Creo Paramet-
ric\2.0\Shipcode.
The config.pro file contains a PROTKDAT line that points to the WBPlugInPE.dat file. This file is
generated either during the product install or by running the CAD Configuration Manager to configure
the Mechanical APDL /ANSYS Workbench products for Creo Parametric.
The <proe_platform> variable is the name that Creo Parametric gives to its platform directories:
WBPlugInPECOM
**These variables are not supported by Creo Parametric and are ignored by Creo Parametric.
See Setting ANSYS Configuration Parameters in the Connection User's Guide for more information about
the config.anscon.162 file.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 61
Configuring CAD Products
PROE_START_CMD162
Specifies the name of the .bat file which launches Creo Parametric on the system. The path to the execut-
able should be already set if the Creo Parametric installation path has been defined for the PATH environ-
ment setting.
8.1.6. NX Configuration
Running the CAD Configuration Manager for NX performs the following steps to activate the NX plug-
in:
If not already present, adds an entry to the custom_dirs.dat file specifying the location of the Plug-In,
e.g., C:\Program Files\ANSYS Inc\V162\AISOL\CADIntegration\UnigraphicsNX\winx64.
Registers the Plug-In file (DSPlugInUGCOM.dll). For the previous example, these files would be located
in C:\Program Files\ANSYS Inc\V162\AISOL\CADIntegration\Unigraphic-
sNX\winx64\startup.
Specific to Windows 8.1, when NX 10 is configured for the associative Workbench reader during the
end of the install, the CAD Configuration Manager incorrectly shows an error that says "Configure Failed
- Registration Error". However the configuration is still successful, and this error message can be ignored.
When multiple NX versions are installed on a system, the UGII_BASE_DIR environment variable
must be set to the install path of the NX version to be launched, prior to starting that version of
the CAD. Otherwise errors will be encountered during CAD startup and the plug-in will not load.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
62 of ANSYS, Inc. and its subsidiaries and affiliates.
Configuring CADNexus/CAPRI CAE Gateway for CATIA V5
For example, if switching from NX 8.5 to run NX 9.0, you must update UGII_BASE_DIR to the NX
9.0 path before starting NX 9.0. Similarly, the UGII_ROOT_DIR environment variable must be set to
the ugii subdirectory in the install path of the NX version to be launched.
When Teamcenter Unified is detected, the environment variable TC_ROOT is set to the Teamcenter Unified
installation path.
2. Install CATIA V5 and LUM licensing (requires a CATIAV5 license key MD2, HD2 or ME2).
3. From the ANSYS, Inc. Customer Portal, download the CADNexus/CAPRI CAE Gateway for CATIA V5 for
your platform to a temporary folder. (Do not download to a folder containing blank spaces in the folder
name, e.g., Program Files). Follow the download procedures described in Downloading the Installation
Files (p. 16).
4. Extract the contents of the zip file using your standard zip utility.
5. Install CADNexus/CAPRI CAE Gateway for CATIA V5 using the appropriate exe for your platform.
6. Follow the instructions on the CAPRI installation screens to complete the installation. When specifying
the component to install, you will need to select the desired CatiaV5 release under CAPRI CAD Applications.
When asked if CAPRI should set the environment variables, click Yes.
7. Run the CAD Configuration Manager and select the Catia V5: CADNexus/CAPRI CAE Gateway option
to complete the configuration as described in Using the CAD Configuration Manager (p. 53).
Note
Using the CAD Configuration Manager to set up the CADNexus/CAPRI CAE Gateway
does not require administrative rights, although installing that product (step 5) requires
these rights. However, if you want to reconfigure to use the ANSYS Workbench Reader
for Catia V5, administrative rights are required.
If you want to revert to the standard CATIA V5 interface, run the CAD Configuration Manager and
select the Catia V5: Standard Interface option to complete the configuration as described in Using
the CAD Configuration Manager (p. 53).
You cannot run the standard CATIA V5 interface simultaneously with the CADNexus/CAPRI CAE Gateway
for CATIA V5 interface.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 63
Configuring CAD Products
2. Copies the following folders from the Workbench installation into the bundle's AutoCAD sub-folders:
All files within <ANSYS 16.0 Install Path>\aisol\CADIntegration\DWG\winx64 are copied to %PROGRAM-
DATA%\ApplicationPlugins\AnsysWB.bundle\Contents\v162\winx64\AutoCAD\2013
All files within <ANSYS 16.0 Install Path>\aisol\CADIntegration\DWG\images are copied to %PROGRAM-
DATA%\Autodesk\ApplicationPlugins\AnsysWB.bundle\Contents\v162\winx64\AutoCAD\Resources
All folders within <ANSYS 16.0 Install Path>aisol\CADIntegration\DWG\Language are copied to %PRO-
GRAMDATA%\Autodesk\ApplicationPlugins\AnsysWB.bundle\Contents\v162\winx64\AutoCAD\Re-
sources\Language
Winx64/AutoCAD/Resources/cadAutoCAD.html" Icon="./Contents/v162/Winx64/AutoCAD/Resources/ansys70.bmp"
LoadOnRequest="True">
<Commands GroupName="ANSYS_Workbench_Geometry_Interface">
</Commands>
</ComponentEntry>
AutoCAD/Resources/Language/
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
64 of ANSYS, Inc. and its subsidiaries and affiliates.
Configuring AutoCAD
en-us/Workbench150.cuix" />
</Components>
</ApplicationPackage>
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 65
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
66 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 9: Uninstalling the Software
Use this process to uninstall any ANSYS, Inc. product that was installed using the Unified Installation
process.
Note to CFX Users The provided uninstall tool cannot uninstall MPI services. If you have CFX products
installed that you are uninstalling, you must stop the MPI services before continuing with the uninstall:
2. Search for "IBM Platform MPI Remote Launch" and if found, click Stop.
3. Search for "Intel(R) MPI Library Process Manager" and if found, click Stop.
Uninstall Procedure for All Users All users should use the following procedure to uninstall ANSYS,
Inc. products.
2. From Windows 7, select Start > All Programs > ANSYS 16.2 > Uninstall 16.2. From Windows 8.1, right-
click the Start Screen> All apps> ANSYS 16.2> Uninstall 16.2. You must uninstall with the same or
higher privileges than were used to install the product, and we strongly recommend uninstalling as the
same user who installed the product originally.
3. Select the product(s) to be uninstalled and unconfigured and click Uninstall Selected Item(s). Not all
products and product components may be listed individually.
4. You will be asked to save all data and close all Windows applications before continuing. Click OK.
5. You will be asked if you are sure you want to uninstall the selected products. Click Yes.
Note
After all the desired products are uninstalled, you are presented with a message
stating that any files or directories that were not recognized by our uninstall program
remain. These remaining files typically include such things as .udf files, user custom-
ized documentation, and various routines. If these files are no longer required,
please remove them manually.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 67
Uninstalling the Software
If you choose to uninstall standalone CFD-Post without uninstalling the other products, the uninstall program
will not uninstall CFD-Post.
If you choose to uninstall all of the other products that include standalone CFD-Post but you do not select
CFD-Post, then CFD-Post will not be removed.
Individual product directories may not be removed if they contain components that are shared with
other products that have not been uninstalled. However, the uninstalled product will no longer run.
In the case of a platform (file server) installation, the uninstall will remove the selected product(s) from
all of the Windows platforms.
This procedure removes the specified ANSYS, Inc. program from your system but will not remove the
ANSYS licensing components. Follow the steps in Uninstalling Licensing Components (p. 68) to uninstall
the licensing components.
1. Stop the ANSYS, Inc. License Manager via the ANSYS License Management Center.
2. Uninstall the ANSYS, Inc. License Manager service. You must use the following command to do so:
"C:\Program Files\ANSYS Inc\Shared Files\Licensing\<platform>\ansysli_server"
-k uninstall
4. Remove the ANSYS, Inc. License Manager folder from the Start menu.
2. Remove the ANSYS 16.2> ANSYS Client Licensing folder from the Start menu or from the Apps screen.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
68 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 10: Troubleshooting
10.1. Installation Troubleshooting
This section lists problems and error messages that you may encounter while installing and/or running
ANSYS, Inc. products. After each situation description or error message is the user action required to
correct the problem.
You can also find answers to commonly-asked questions on our customer portal. After you log in to
the customer portal, select Knowledge Resources> Solutions.
For information on licensing-related errors, see the Troubleshooting section of the ANSYS, Inc. Licensing
Guide.
The client-related diagnostic information can be gathered by using the Client ANSLIC_ADMIN utility.
For more information, see, Gather Client Diagnostic Information.
The server-related diagnostic information can be gathered by using ANSYS License Management
Center or by using the standalone gatherdiagnostics script. For more information, see, Gathering
Diagnostic Information.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 69
Troubleshooting
If this program didn't install correctly, try reinstalling using settings that are compatible with this
version of Windows.
This message is caused by the Windows Program Compatibility Assistant and can safely be ignored.
Click Cancel and continue with the uninstall.
If you are running ICEM CFD over the network and you have applied this security update, you may not
be able to access ICEM CFD Help using the Help menu. To access ICEM CFD Help, navigate to common-
files\help\en-us in the installation directory on the server machine and copy the file icem-
cfd_help.chm to your local machine. Double-click the local copy to view the help.
If DEP is set, you will need to add ANSYS to the list of exceptions. For more information on DEP and
how to change the settings, see http://support.microsoft.com/kb/875351.
10.1.6. Product Installation Does Not Create Start Menu Item for ANSYS and
CAD Plugins Do Not Work
On a Windows 7 or Windows 8.1 system, if you install ANSYS, Inc. products but do not see a Start
Menu/Apps item and your CAD plugins do not work, the TEMP environment variable may be pointing
to an inaccessible location. For example, it may point to a location such as %USERPROFILE%\Local
Settings\Temp. As a result, the product installation could end without configuring the product
correctly. You should ensure that the TEMP variable points to a valid location, such as %USERPRO-
FILE%\AppData\Local\Temp.
Alternatively, you can run the prerequisite check to verify that you have all the necessary prerequisites.
If necessary, install any prerequisites and rerun the installation:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
70 of ANSYS, Inc. and its subsidiaries and affiliates.
Installation Troubleshooting - Mechanical APDL and ANSYS Workbench Products
2. Install any missing prerequisites by running InstallPreReqs.exe from the top level directory as an
administrator.
3. When the prerequisites have finished installing, run the installation as you normally would (GUI or silently).
This message indicates that the ANSYS162_DIR environment variable was not set where necessary
for licensing. This environment variable should be set to the installation directory.
If you encounter this type of message on a server configuration, you may need to set the machine
as a trusted site. On a Windows 7 or Windows 8.1 machine, in the Control Panel, select Network
and Internet, select Internet Options, and select Security. Click on Trusted Sites and click Sites.
Add the machine as file://servername.
If you are configuring to a server with spaces in the path and get this error, then you must put
quotes around your server specification as shown in the following example:
C:\Users\>C:\Windows\Microsoft.NET\Framework\v2.0.50727\CasPol.exe -m -a
g 1.2 -url file://"\\machineabc\ANSYS Inc\*" FullTrust
Windows includes a function called Aero that may cause Mechanical APDL graphing or plotting problems
in 3-D mode on some systems. If this problem occurs, disable the Windows Aero theme in Windows 7
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 71
Troubleshooting
when running Mechanical APDL. If you are using Windows 8.1, please follow the steps below to correct
this issue.
The Make the computer easier to see window opens. Please note that you can access this window
in a number of ways.
4. Enable the Turn off all unnecessary animations (when possible) option.
5. Click Ok.
If certain options are grayed out, your account may not have the necessary system administrator
privileges necessary to run those options.
***Cannot create required <profile> file. Therefore, cannot write to profile information during
this launcher session.
If you see this error, you cannot add or modify profile information during this launcher session.
Verify that you have write access to the directory and restart the launcher session. Typically, this
directory is C:\Documents and Settings\<user name>\Application Data\AN-
SYS\v162\launcher on Windows or ~/.ansys/v162/launcher/ on UNIX.
Verify your Mechanical APDL product installation. If the desired product was not installed, install it.
Error executing Mechanical APDL. Refer to System-related Error Messages in the Mechanical APDL
online help. If this was a Distributed Mechanical APDL job, verify that your MPI software is installed
correctly, check your environment settings, or check for an invalid command line option.
You may see this error if you did not correctly run the set password bat file. Verify that you completed
this item according to the IBM Platform MPI installation readme instructions.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
72 of ANSYS, Inc. and its subsidiaries and affiliates.
Installation Troubleshooting - Mechanical APDL and ANSYS Workbench Products
You may also see this error if ANSYS Inc\v162\ansys\bin\<winx64> is not in your PATH.
SET ANS_SEE_RUN=TRUE
SET ANS_CMD_NODIAG=TRUE
Problem Situations
CAD System Plug-In Menus Do Not Appear for NX or Creo Parametric ANSYS Workbench on
Windows platforms will append its information to an existing customization file for NX and/or Creo
Parametric. If no customization file exists, ANSYS Workbench will create a file. For NX, ANSYS Workbench
looks for the custom_dirs.dat file in the directory specified via the UGII_CUSTOM_DIRECTORY_FILE
environment variable. For Creo Parametric, ANSYS Workbench looks for the config.pro file in the
%HOMEDRIVE%%HOMEPATH% directory. In addition, during setup of the Creo Parametric Geometry In-
terface, ANSYS Workbench will also append its information to the config.pro file located in the Creo
Parametric installation path, under the \text directory (e.g., Proewildfire2\text\config.pro).
If ANSYS Workbench encounters a read-only file, it will not be able to write the necessary information
to the file. In this case, you will need to revise the permissions on the file and manually add the appro-
priate ANSYS Workbench-specific information in order for the ANSYS menu to appear in NX or Creo
Parametric.
Script Errors When Running ANSYS Workbench If you encounter script errors such as "Error: Unable
to create object microsoft.XMLDOM," you may need to install the latest version of Microsoft's MSXML.
Please visit Microsoft's web site at http://www.microsoft.com/downloads/details.aspx?FamilyID=993c0bcf-
3bcf-4009-be21-27e85e1857b1&DisplayLang=en for more information on downloading and installing
MSXML.
Another application might be using the Solver Manager port (10002 by default). Try changing the
port number by editing the Ansys.SolverManager.exe.config file located in the installation
directory at \AISOL\Bin\<platform>.
If you are getting the "Unable to connect to Solver Manager" error message or are having difficulty
launching other applications/editors, it is also possible that the Windows hosts file has been corrupted.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 73
Troubleshooting
Please make sure that localhost is specified in the Windows <os drive>:\Windows\sys-
tem32\drivers\etc\hosts file.
If your support is provided by ANSYS, Inc. directly, Technical Support can be accessed quickly and effi-
ciently from the ANSYS Customer Portal, which is available from the ANSYS Website (www.ansys.com)
under Support > Customer Portal. The direct URL is: support.ansys.com.
One of the many useful features of the Customer Portal is the Knowledge Resources Search, which can
be found on the Home page of the Customer Portal. To use this feature, enter relevant text (error
message, etc.) in the Knowledge Resources Search box and click the magnifying glass icon. These
Knowledge Resources provide solutions and guidance on how to resolve installation and licensing issues
quickly.
NORTH AMERICA
All ANSYS Products except Esterel, Apache and Reaction Design products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Toll-Free Telephone: 1.800.711.7199 (Please have your Customer or Contact ID ready.)
Support for University customers is provided only through the ANSYS Customer Portal.
GERMANY
ANSYS Mechanical Products
Telephone: +49 (0) 8092 7005-55 (CADFEM)
Email: support@cadfem.de
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
National Toll-Free Telephone: (Please have your Customer or Contact ID ready.)
German language: 0800 181 8499
English language: 0800 181 1565
Austria: 0800 297 835
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
74 of ANSYS, Inc. and its subsidiaries and affiliates.
Contacting Technical Support
UNITED KINGDOM
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: Please have your Customer or Contact ID ready.
UK: 0800 048 0462
Republic of Ireland: 1800 065 6642
Outside UK: +44 1235 420130
Email: support-uk@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
JAPAN
Mechanical Products
Telephone: +81-3-5324-8333
Email:
Mechanical: japan-ansys-support@ansys.com
Fluids Products
Telephone: +81-3-5324-7305
Email:
Fluent: japan-fluent-support@ansys.com;
CFX: japan-cfx-support@ansys.com;
Polyflow: japan-polyflow-support@ansys.com;
Icepak
Telephone: +81-3-5324-7444
Email: japan-icepak-support@ansys.com
Licensing and Installation
Email: japan-license-support@ansys.com
INDIA
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +91 1 800 209 3475 (toll free) or +91 20 6654 3000 (toll) (Please have your Customer or
Contact ID ready.)
Support for University customers is provided only through the ANSYS Customer Portal.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 75
Troubleshooting
FRANCE
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Toll-Free Telephone: +33 (0) 800 919 225 Toll Number: +33 (0) 170 489 087 (Please have your Customer
or Contact ID ready.)
Email: support-france@ansys.com
BELGIUM
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +32 (0) 10 45 28 61
Email: support-belgium@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
SWEDEN
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +46 (0) 10 516 49 00
Email: support-sweden@ansys.com
ITALY
All ANSYS Products
Web: Go to the ANSYS Customer Portal (http://support.ansys.com) and select the appropriate option.
Telephone: +39 02 89013378
Email: support-italy@ansys.com
Support for University customers is provided only through the ANSYS Customer Portal.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
76 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 11: Applications Included with Each Product
The following table displays which ANSYS, Inc. applications are included with each of the product in-
stallation options.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 77
Applications Included with Each Product
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
78 of ANSYS, Inc. and its subsidiaries and affiliates.
Configuring High Performance Computing
The information in this guide applies to all ANSYS, Inc. products released on or after this date, until superceded
by a newer version of this guide. This guide replaces individual product installation guides from previous releases.
2015 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT, HFSS, AIM
and any and all ANSYS, Inc. brand, product, service and feature names, logos and slogans are registered trademarks
or trademarks of ANSYS, Inc. or its subsidiaries in the United States or other countries. ICEM CFD is a trademark
used by ANSYS, Inc. under license. CFX is a trademark of Sony Corporation in Japan. All other brand, product,
service and feature names or trademarks are the property of their respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
List of Tables
1. Products with Limited HPC Functionality ................................................................................................... 1
2. Platforms and MPI Software ....................................................................................................................... 2
3. LS-DYNA MPP MPI Support on Windows and Linux .................................................................................... 3
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
Configuring Distributed ANSYS
This section explains how to configure your network/cluster to run Distributed ANSYS. It is important
that you follow these steps in order to run successfully in a distributed environment.
You will need an ANSYS Mechanical HPC (HPC) license for each processor after the first two. For example,
if you want to run four processors, you will need two HPC licenses. Some products cannot use all HPC
functionality, as noted in the following table.
Distributed ANSYS allows you to use two cores without using any HPC licenses. Additional licenses will be
needed to run a distributed solution with more than two cores. Several HPC license options are available.
For more information, see HPC Licensing in the Parallel Processing Guide.
If you are running on a single machine, there are no additional requirements for running a distributed
solution.
If you are running across multiple machines (e.g., a cluster), your system must meet these additional
requirements to run a distributed solution.
Homogeneous network: All machines in the cluster must be the same type, OS level, chip set, and intercon-
nects.
You must be able to remotely log in to all machines, and all machines in the cluster must have identical
directory structures (including the ANSYS 16.2 installation, MPI installation, and on some systems, working
directories). Do not change or rename directories after you've launched ANSYS. For more information on
files that are written and their location, see Controlling Files that Distributed ANSYS Writes in the Parallel
Processing Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Configuring Distributed ANSYS
All machines in the cluster must have ANSYS 16.2 installed, or must have an NFS mount to the ANSYS 16.2
installation. If not installed on a shared file system, ANSYS 16.2 must be installed in the same directory path
on all systems.
All machines must have the same version of MPI software installed and running. The table below shows the
MPI software and version level supported for each platform. For Linux platforms, the MPI software is included
with the ANSYS 16.2 installation. For Windows platforms, you must install the MPI software as described
later in this document.
ANSYS LS-DYNA If you are running ANSYS LS-DYNA, you can use LS-DYNA's parallel processing (MPP
or SMP) capabilities. Use the launcher or the command line method as described in Activating Distributed
ANSYS in the Parallel Processing Guide to run LS-DYNA MPP. For Windows and Linux systems, please see
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting up Distributed ANSYS
the following table for LS-DYNA MPP MPI support. For more information on using in ANSYS LS-DYNA
general, and its parallel processing capabilities specifically, see the ANSYS LS-DYNA User's Guide.
The instructions for installing Platform MPI are also found in the installation directory in the following
README files:
or
The instructions for installing Intel MPI are also found in the installation directory in the following
README files:
or
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
Configuring Distributed ANSYS
or
Microsoft HPC Pack examples are also located in Program Files\ANSYS Inc\V162\common-
files\MPI\WindowsHPC. Jobs are submitted to the Microsoft HPC Job Manager either from the
command line or the Job Manager GUI.
To submit a job via the GUI, go to Start> All Programs> Microsoft HPC Pack> HPC Job Manager.
Then click on Create New Job from Description File.
Windows 7:
Right-click on My Computer, left-click on Properties, and select the Network Identification or
Computer Name tab. The full computer name will be listed. Note the name of each machine (not
including the domain).
Windows 8.1:
From the All apps screen, open the Control Panel. Click Systemand Security> System. The full
computer name will be listed. Note the name of each machine (not including the domain).
Linux:
Type hostname on each machine in the cluster. Note the name of each machine. You will need this
name to set up the .rhosts file, as well as for the ANS_ADMIN utility.
2. Linux only: Set up the .rhosts file on each machine. The .rhosts file lists all machines in the cluster.
The machines should be listed using their complete system name, as taken from hostname. For example,
an .rhosts file for a two-machine cluster might look like this:
golinux1.ansys.com jqd
golinux2 jqd
Verify communication between machines via rsh or ssh (e.g., rsh golinux2 ls). You should
not be prompted for a password. If you are, check the .rhosts permissions and machine names
for correctness. For more information on using remote shells, see the man pages for rsh or ssh.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting up Distributed ANSYS
3. If you want the list of machines to be populated in the Mechanical APDL Product Launcher, you need to
configure the hosts162.ans file. You can use the ANS_ADMIN utility to configure this file. You can
manually modify the file later, but we strongly recommend that you use ANS_ADMIN to create this file
initially to ensure that you establish the correct format.
Windows 7:
Start >Programs >ANSYS 16.2 >Utilities >ANS_ADMIN 16.2
Windows 8.1:
All apps >ANSYS 16.2 > ANS_ADMIN 16.2
Linux:
/ansys_inc/v162/ansys/bin/ans_admin162
Under Select file to configure, choose the hosts162.ans file to be configured and choose
Configure for Distributed ANSYS. Click OK.
Enter the system name (from Step 1) in the Machine hostname field and click Add. On the next
dialog box, enter the system type in the Machine type drop-down, and the number of cores in
the Max number of jobs/processors field. Click Add. Repeat this step for each machine in the
cluster.
When you are finished adding machines, click Close then File > Exit.
The hosts162.ans file should be located in your current working directory, your home directory,
or the apdl directory. All three locations are equally valid; the location should be chosen based
on user preference.
4. Windows only: Verify that all required environment variables are properly set. If you followed the post-
installation instructions described above for Microsoft HPC Pack (Windows HPC Server 2008 / 2012), these
variable should be set automatically.
On the head node, where ANSYS 16.2 is installed, check these variables:
where C:\Program Files\ANSYS Inc is the location of the product install and C:\Program
Files\ANSYS Inc\Shared Files\Licensing is the location of the licensing install. If your
installation locations are different than these, specify those paths instead.
On Windows systems, you must use the Universal Naming Convention (UNC) for all ANSYS, Inc.
environment variables on the compute nodes for Distributed ANSYS to work correctly.
ANSYS162_DIR=\\head_node_machine_name\ANSYS Inc\v162\ansys
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
Configuring Distributed ANSYS
On the head node and the compute nodes, set LSTC_LICENSE to ANSYS. This tells the LS-DYNA
executable to use ANSYS, Inc. licensing.
Since the LS-DYNA run will use ANSYS, Inc. licensing for LS-DYNA, you do not need to set
LSTC_LICENSE_SERVER.
5. Windows only: Share out the ANSYS Inc directory on the head node with full permissions so that the
compute nodes can access it.
On Linux systems, you can also set the following environment variables:
ANSYS_NETWORK_START - This is the time, in seconds, to wait before timing out on the start-up of
the client (default is 15 seconds).
ANSYS_NETWORK_COMM - This is the time to wait, in seconds, before timing out while communicating
with the client machine (default is 5 seconds).
ANS_SEE_RUN_COMMAND - Set this environment variable to 1 to display the actual mpirun command
issued from ANSYS.
MPI_REMSH - This is the path to the remote shell (ssh or rsh). Set this environment variable to specify
a full path to a remote shell. For example, setting MPI_REMSH = /usr/bin/ssh will use ssh instead
of the default remote shell (rsh). Note that selecting the Use Secure Shell instead of Remote Shell
option on the launcher will override MPI_REMSH, if MPI_REMSH is not set or is set to a different location.
You can also issue the -usessh command line option to use ssh instead of rsh. The command line
option will override the environment variable setting as well.
MPI_WORKDIR - Set this environment variable to specify a working directory on either the master and
all nodes, or on specific nodes individually. For more information, see Controlling Files that Distributed
ANSYS Writes.
MPI_IC_ORDER - Set this environment variable to specify the order in which the interconnects on the
system are to be used. The interconnects will be tried in the order listed from left to right. If an inter-
connect is listed in uppercase, no interconnects listed after that one will be tried. If MPI_IC_ORDER is
not set, the fastest interconnect available on the system is used. See the Platform MPI documentation
for more details.
MPI_ICLIB_<interconnect> - Set this environment variable to the interconnect location if the in-
terconnect is not installed in the default location:
setenv MPI_ICLIB_GM <path>/lib64/libgm.so
See the Platform MPI documentation for the specific interconnect names (e.g., MPI_ICLIB_GM).
MPIRUN_OPTIONS - Set this environment variable to -prot to display a grid of interconnects among
the systems being used for distributed processing.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
Setting up Distributed ANSYS
Issue the command line option -usessh to use ssh instead of rsh.
See the Intel MPI reference manual (for Linux) for further information and additional environment
variables and their settings: http://software.intel.com/en-us/articles/intel-mpi-library-documentation/.
To verify that these environment variables are set correctly on each machine, run:
rsh machine1 env
On Windows systems, you can set the following environment variables to display the actual mpirun
command issued from ANSYS:
ANS_SEE_RUN = TRUE
ANS_CMD_NODIAG = TRUE
When running the mpitest program, you must use an even number of nodes.
On Linux:
You can use any of the same command line arguments (such as -machines) with the mpitest program
as you can with Distributed ANSYS.
On Windows:
Issue the following command to run a local test on Windows using Platform MPI:
ansys162 -np 2 -mpitest
Use the following procedure to run a distributed test on Windows using Platform MPI:
1. Create a file named machines in your local/home directory. Open the machines file in an editor.
2. Add your master and slave machines in your cluster. For example, in this cluster of two machines, the
master machine is gowindows1. List the machine name separately for each core on that machine. For
example, if gowindows1 has four cores and gowindows2 has two, the machines file would look like
this:
gowindows1
gowindows1
gowindows1
gowindows1
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
Configuring Distributed ANSYS
gowindows2
gowindows2
3. From a command prompt, navigate to your working directory. Run the following:
ansys162 -mpifile machines -mpitest
Distributed ANSYS supports the following interconnects. Not all interconnects are available on all plat-
forms; see http://www.ansys.com/Support/Platform+Support for a current list of supported interconnects.
Other interconnects may work but have not been tested.
InfiniBand (recommended)
Myrinet
GigE
Interconnects plug into a PCI (Peripheral Component Interconnect), PCI-X (extended), or PCIe (PCI Express)
slot on the system. You will need a PCI-X or a PCIe slot for the faster interconnects to accommodate
the higher speeds.
Hardware for specific types of interconnects is generally incompatible with other proprietary interconnect
types (except Ethernet and GiGE).
Systems can have a network of several different types of interconnects. Each interconnect must be as-
signed a unique hostname and IP address.
On Windows x64 systems, use the Network Wizard in the Compute Cluster Administrator to configure
your interconnects. See the Compute Cluster Pack documentation for specific details on setting up the
interconnects. You may need to ensure that Windows Firewall is disabled for Distributed ANSYS to work
correctly.
For more information on using Distributed ANSYS, see the Parallel Processing Guide.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
Configuring ANSYS CFX Parallel
If you have purchased the ANSYS CFX-Solver parallel option, you will need to follow the procedures in
this chapter to ensure that users can execute ANSYS CFX jobs in parallel. Several parallel communication
methods are available that use either MPI (Message Passing Interface) or PVM (Parallel Virtual Machine).
Platform-specific versions of MPI are available in some instances.
The ANSYS CFX-Solver parallel option is supported on all platforms that support the CFX-Solver.
The ANSYS CFX-Solver must be installed on both master and slave nodes.
To run distributed parallel (where slave processes run on a different host to the master process), remote or
secure shell access must be available from the master nodes (systems on which parallel runs will be started)
to slave nodes (systems on which the ANSYS CFX-Solver will actually run). See Setting Up Remote Access
on Linux (p. 9), below.
The hostinfo.ccl file should be set up, as described in hostinfo.ccl File (p. 10).
Often, networks where ssh, rsh or rlogin are used frequently will already be configured to allow remote
access to all users. If this is the case, nothing more needs to be done.
The CFX5RSH environment variable is used to select the remote shell protocol. By default, CFX5RSH=ssh
is set. If you want to use rsh, then set CFX5RSH=rsh either in the environment or in the cfx5rc file
(see Resources Set in cfx5rc Files in the CFX Introduction).
In either case, ssh or rsh, the remote machine must not prompt for a password when you run remote
commands.
You can test remote access using rsh for a Linux slave node using the command:
rsh unixhost echo working
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
Configuring ANSYS CFX Parallel
where <master> is the hostname of the master node. See your system documentation for more in-
formation about the use of rsh and the syntax of the hosts.equiv file.
If NIS is used to control remote access, then a netgroup must be created for users of ANSYS CFX by the
root user on the NIS master server, and a line such as the one below added to /etc/hosts.equiv
on each slave node by the root user:
+@<netgroup>
where <netgroup> is the name of a netgroup to which users of ANSYS CFX belong. A detailed descrip-
tion of how to configure NIS is beyond the scope of this manual. Please see your system documentation
for more information about NIS.
where <master> is the hostname of the master and <user> is their username on the master. This
file should be made readable only by the user, for example, by running:
chmod 600 ~/.rhosts
This file is written using the CFX Command Language. It defines a set of HOST DEFINITION objects, one
for each available node. For example:
SIMULATION CONTROL:
EXECUTION CONTROL:
PARALLEL HOST LIBRARY:
HOST DEFINITION: kangaroo
Installation Root = /ansys_inc/v%v/CFX
END
HOST DEFINITION:wallaby
Installation Root = /usr/local/cfx
Host Architecture String = linux-amd64
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Linux Parallel Setup
Number of Processors = 16
Relative Speed = 1.7
END
HOST DEFINITION: mypc
Remote Host Name = my_pc
END
END
END
END
Note
If you manually create your hostinfo.ccl file, you must ensure that the SIMULATION
CONTROL...END wrapper is present.
None of the values for each host are mandatory, and the following empty host definition is perfectly
valid:
HOST DEFINITION: parakeet
END
Host names are limited to the set of valid CCL object names. In particular, they must not contain full
stops (.) or underscores (_) and must start with a letter.
If a hostinfo.ccl file does not already exist when ANSYS CFX is installed, one will be created con-
taining the installation host. You can add hosts to the hostinfo.ccl file using the cfx5parhosts
utility, or by modifying the file using a text editor. Individual users may also create their own versions
of this file in:
~/.hostinfo.ccl
For most installations, it will be necessary to supply only the Installation Root parameter, which should
point to the <CFXROOT> directory in which ANSYS CFX is installed. On mixed architectures, you may
find it useful to supply the Number of Processors and/or Relative Speed parameters. A little time may
be saved at startup by giving the Host Architecture String parameter explicitly, for example, using the
cfx5parhosts utility.
Tip
If an individual user wants to use a host that is not present in either the hostinfo.ccl
in the installation config directory or the user's own version of this file, then the user can
add this host to the list for a particular run by using the CFX-Solver Manager. However, this
would have to be done each time a run is started.
Installation Root
This is set to the <CFXROOT> installation directory on this host. If it is set to the special string none, this
indicates that there is no ANSYS CFX installation on the remote host, which can sometimes be useful if
only the solver binary is available.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
Configuring ANSYS CFX Parallel
When these short os values (for example, linux-amd64) are given in this position, the generic solver ex-
ecutable will always be used for this host. The string can also be set to the actual architecture of the remote
host (for example, intel_xeon64.sse2_linux2.3.4), which is determined by giving the command <CFX-
ROOT>/bin/cfx5info -arch. If these longer strings are used then CFX could use this information to
select between solvers optimized for specific architectures. However, since there are currently no solvers
optimized for specific architectures, this extra information is currently unused.
Number of Processors
As implied, this is the number of processors on the machine. It is used for display purposes only and can
be safely omitted.
Relative Speed
The Relative Speed is a real number that is used by the ANSYS CFX-Solver when partition sizes are calculated.
The ratio of relative speeds of each host is used to determine the size of each partition. As an example,
consider a parallel run involving two machines, one with a relative speed of 2.0 and the other with a relative
speed of 1.0. The faster machine would work on a partition size twice as large as the slower machine in
this case.
The numbers themselves are arbitrary; as a guide you may want to set 1.0 for a 1 GHz processor,
0.75 for a 750 MHz processor, and so on. If a relative speed entry is not entered, a default of 1.0 is
assumed for that host.
You can obtain relative speed values using the cfx5parhosts utility.
Solver Executable
A solver executable may be explicitly supplied, if necessary. This is usually only required when using Install-
ation Root = none, and is recommended for advanced users only. The following substitutions are made
on the string:
1.2.1. Adding Hosts for Parallel Processing with the cfx5parhosts Utility
You can add new hosts to ANSYS CFX's database for parallel runs using the cfx5parhosts utility:
CFXROOT\bin\cfx5parhosts argument list
where argument list corresponds to one or more of the arguments listed below:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Linux Parallel Setup
Argument Description
-add host[,host,...] Add information about the named hosts to the file. This assumes that
ANSYS CFX is installed in the same directory on each listed host as on the
host on which you are running.
IBM Platform MPI supports several communication modes including shared memory and networked
TCP/IP (Ethernet), luDAPL, VAPI, OpenFabrics (IB), GM-2, MX (Myrinet), Elan4 (Quadrics), QLogic InfiniPath,
and EtherFabric (Level 5 Networks).
IBM Platform MPI is automatically installed with ANSYS CFX in the <CFXROOT>/tools directory. You
do not need a license from Platform to run the ANSYS CFX-Solver using IBM Platform MPI.
IBM Platform MPI run modes are selected in the ANSYS CFX-Solver Manager or on the command line
(using the -start-method command line option) using the Platform MPI Local Parallel or Platform
MPI Distributed Parallel start method options.
For IBM Platform MPI, the cpu_bind option is used by default and binds processes to cores using a
cyclic order. This leads to better performance but, on multi-user clusters having scheduling systems
that do not enforce exclusive use of cluster nodes, may cause problems because multiple jobs may be
bound to the same CPU on the same node. In this case, the cpu_bind argument to mpirun should
be removed from the IBM Platform MPI start methods in the <CFXROOT>/etc/start_methods.ccl
file.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
Configuring ANSYS CFX Parallel
ANSYS CFX uses the environment variable CFX5_PCMPI_DIR to select which IBM Platform MPI installation
is used. The default setting points to the version that is automatically installed with ANSYS CFX in the
<CFXROOT>/../commonfiles/MPI/Platform directory. You can use cfx5info -v to find the current
settings for CFX5_PCMPI_DIR and other environment variables. If you want to use a different IBM Platform
MPI version, you can install that version in an alternative location and set CFX5_PCMPI_DIR to that
location. For distributed parallel runs, IBM Platform MPI must be present at the same location (same
absolute path) on all hosts. Typically, this is achieved by using a central ANSYS CFX installation, accessible
by all hosts. In order to run a CFX job in distributed parallel using IBM Platform MPI on hosts with dif-
ferent CFX installation locations, you must first install IBM Platform MPI under the same location (same
absolute path) on each host, then set the environment variable CFX5_PCMPI_DIR to the location under
which IBM Platform MPI was installed.
There are several environment variables that can be used to control IBM Platform MPI (documented in
the IBM Platform MPI documentation) that may provide additional flexibility not directly accessible
through the ANSYS CFX startup scripts. If these environment variables are set the startup scripts auto-
matically set them for your ANSYS CFX runs. Some useful environment variables include:
MPI_REMSH
Enables you to change which method is used by IBM Platform MPI to spawn jobs on remote machines.
The IBM Platform MPI default is ssh. However, by default the ANSYS CFX software sets this to be the same
as the setting used for CFX5RSH, and rsh if CFX5RSH is not set. This variable is applicable only to Linux and
HP-UX.
MPI_IC_ORDER
Enables you to change the default order in which IBM Platform MPI searches for interconnects.
If you want to force selection of a specific device, then you can either modify the start command in the
etc/start-methods.ccl file and add the necessary command line flags (for example: -GM to force
selection of the Myrinet interconnect) or use the appropriate IBM Platform MPI environment variables.
Some useful command line options include forcing other interconnect types (-TCP, -HMP, -ELAN, -ITAPI,
-VAPI, -UDAPL, and so on), using prun on systems with quadrics support (-prun), XC support (-srun) and
setting the subnet you want to use (-subnet, sometimes useful for selecting particular interconnects as
well if your system is configured that way).
For some Linux-based cluster environments not supported by IBM Platform MPI, it is possible that the
Myrinet, Infiniband or Quadrics hardware drivers are not located where IBM Platform MPI expects. If
IBM Platform MPI cannot detect the drivers for fast interconnects, it will generally default back to the
lowest speed connection that it can detect (usually TCP/IP socket communication).
The following table gives information on the default search path IBM Platform MPI uses to find drivers
for the various communication interfaces:
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Linux Parallel Setup
For example, IBM Platform MPI expects that GM stack shared libraries for Myrinet interconnects are
located either in the default library search path or in the /opt/gm/lib64 (64 bit x86) directories. If the
shared libraries are not in either location, IBM Platform MPI will not take advantage of the high-speed
interconnects. To fix this, you will have to copy the shared libraries into the correct location or set the
environment variable MPI_ICLIB_GM to point to the correct GM stack shared library.
DAPL-capable network fabrics, such as Infiniband, iWarp, Dolphin and XPMEM (through DAPL).
TMI-capable network fabrics including Qlogic and Myrianet (through Tag Matching Interface).
Intel MPI run modes are selected in the ANSYS CFX-Solver Manager or on the command line (using the
-start-method command line option) using the Intel MPI Local Parallel or Intel MPI Distributed Parallel
start method options.
ANSYS CFX uses the environment variable CFX5_IMPI_DIR to select which Intel MPI installation is used.
The default setting points to the version that is automatically installed by ANSYS CFX in the<CFX-
ROOT>/../commonfiles/MPI/Intel directory. You can use cfx5info -v to find the current settings
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
Configuring ANSYS CFX Parallel
for CFX5_IMPI_DIR and other environment variables. If you want to use a different Intel MPI version,
you can install that version in an alternative location and set CFX5_IMPI_DIR to that location.
There are several environment variables that can be used to control Intel MPI that may provide addi-
tional flexibility that is not directly accessible through the ANSYS CFX start-up scripts. For example,
environment variables are available for network fabric selection (discussed briefly below), process pinning
control, and collective operation control.
Any of these environment variables can be set by modifying the start command in the etc/start-
methods.ccl file and using the Intel MPI options -env and/or -genv (an example of this usage is
given in the section on network fabric selection). More detail on all options and environment variables
is available in the Intel MPI documentation.
Some useful environment variables include those described below. If these environment variables are
set the start-up scripts automatically set them for your ANSYS CFX runs.
I_MPI_MPD_REMSH
Specifies which method is used by Intel MPI to spawn jobs on remote machines. The Intel MPI default is
ssh. However, by default the ANSYS CFX software sets this to be the same as the setting used for CFX5RSH,
and rsh if CFX5RSH is not set. This variable is applicable only to Linux.
If you want to force selection of a specific network fabric, then you can either set the I_MPI_FABRICS
environment variable or modify the start command in the etc/start-methods.ccl file and add
the necessary command line flags (for example: -env IMPI_FABRICS shm:dapl to select the combination
of shared memory and DAPL fabrics) .
The following table shows how Intel MPI searches for drivers for the various network fabrics:
For example, Intel MPI expects that the DAT shared library for the DAPL network fabric is located either
in the default library search path or in a specific location if a full path is specified. If the shared library
cannot be found, Intel MPI will not take advantage of the DAPL network fabric. To fix this, you will have
to install the shared libraries into the correct location or set the environment variable I_MPI_DAT_LIBRARY
to point to the correct DAT shared library.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Windows Parallel Setup
There are other environment variables not documented here which provide further control over network
fabrics selection. These are described in the Intel MPI documentation.
Cray MPI is closely integrated with the batch queuing system and interconnects used on Cray systems.
Cray MPI is the recommended method of running on Cray systems, as opposed to using Cluster Com-
patibility Mode (CCM) with a different MPI.
When starting a solver run, the Cray MPI start method may be specified on the command line using
the option: -start-method Cray MPI Distributed Parallel, having reserved the required
processing elements via the built-in batch queuing system.
Note that numa node memory containment is enforced, using the -ss option. The default method
used by Cray MPI to allocate processes to CPU cores is appropriate when all cores are used. However,
if it is intended that each host is only partly utilized (for example, because of the memory requirements
of the run), this can result in asymmetric utilization. In such cases, the -S option can be used to limit
the number of processes per numa node. For example, -S 4 would limit the number of processes per
numa node to 4.
Local parallel runs use IBM Platform MPI (default) or Intel MPI for communication. For local parallel runs,
the MPI service must be installed and running in order to use Intel MPI, but not IBM Platform MPI.
To run distributed parallel (where slave processes run on hosts other than the host with the master
process), the desired MPI service must be installed, configured, and started on all involved hosts. In
addition, you must make host information available to the master host. These tasks are discussed in
Setting Up IBM Platform MPI for Windows (p. 21) or Setting Up Intel MPI for Windows (p. 22).
(Preferred mechanism) The hostinfo.ccl file on the master host is configured with any required inform-
ation about slave hosts.
The hostinfo.ccl file registers information such as the Installation Root and Host Ar-
chitecture String parameters for hosts used for distributed parallel runs. The hostinfo.ccl
file is created automatically when installing ANSYS CFX. By default, it contains details of the host on
which it is installed.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
Configuring ANSYS CFX Parallel
For hosts that have the same architecture as the machine that runs the master process, registration
in the hostinfo.ccl file is optional; if a particular host is not specified then all of its properties
are assumed to be the same as those of the machine that runs the master process.
For machines that have a machine architecture different from the machine that runs the master
process, the hostinfo.ccl file must include information about the properties that differ from
those of the machine that runs the master process.
If your machine previously had ANSYS CFX installed, then ensure that remote host interrogation is
disabled either by deleting the environment variable CFX_SOLVE_DISABLE_REMOTE_CHECKS or
(equivalently) by setting that environment variable to a value of 1. This environment variable can be
specified in your Windows environment or your user cfx5rc.txt file or site cfx5rc.txt file. See
Resources Set in cfx5rc Files in the CFX Introduction for details.
If ANSYS CFX is to determine the required information for itself, then remote- or secure-shell access
must be available from the master host (the system on which parallel runs will be started) to slave
hosts (systems on which the ANSYS CFX-Solver will actually run). You must be able to execute an rsh
or ssh command on the remote host without typing in your password. Unless you already have your
Windows systems set up to allow this type of access, this method of setting up distributed parallel
is not recommended.
The hostinfo.ccl file is written using the CFX Command Language. It defines a set of HOST
DEFINITION objects, one for each available host. For example:
SIMULATION CONTROL:
EXECUTION CONTROL:
PARALLEL HOST LIBRARY:
HOST DEFINITION: hostname1
Installation Root = C:\Program Files\ANSYS Inc\v%v\CFX
Host Architecture String = winnt-amd64
END # HOST DEFINITION hostname1
END # PARALLEL HOST LIBRARY
END # EXECUTION CONTROL
END # SIMULATION CONTROL
Note
If you manually create your hostinfo.ccl file, you must ensure that the SIMULATION
CONTROL...END wrapper is present.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Windows Parallel Setup
None of the values for each host are mandatory. For example, the following empty host definition is
perfectly valid:
HOST DEFINITION: hostname1
END
Host names are limited to the set of valid CCL object names. In particular, they must not contain full
stops (.) or underscores (_) and must start with a letter.
If a hostinfo.ccl file does not already exist when ANSYS CFX is installed, one will be created con-
taining the installation host. You can add hosts to the hostinfo.ccl file using the cfx5parhosts
utility, or by modifying the file using a text editor.
For most installations, it will be necessary only to supply the Installation Root parameter, which should
point to the <CFXROOT> directory in which ANSYS CFX is installed. On mixed networks, you may find
it useful to supply the Number of Processors and/or Relative Speed parameters. A little time may be
saved at startup by giving the Host Architecture String parameter explicitly, for example, using the
cfx5parhosts utility.
Installation Root
This is set to the <CFXROOT> installation directory on this host. If it is set to the special string none, this
indicates that there is no ANSYS CFX installation on the remote host, which can sometimes be useful if
only the solver binary is available.
Number of Processors
As implied, this is the number of processors on the machine. It is used for display purposes only and can
be safely omitted.
Relative Speed
The Relative Speed is a real number that is used by the ANSYS CFX-Solver when partition sizes are calculated.
The ratio of relative speeds of each host is used to determine the size of each partition. As an example,
consider a parallel run involving two machines, one with a relative speed of 2.0 and the other with a relative
speed of 1.0. The faster machine would work on a partition size twice as large as the slower machine in
this case.
The numbers themselves are arbitrary; as a guide you may want to set 1.0 for a 1 GHz processor,
0.75 for a 750 MHz processor, and so on. If a relative speed entry is not entered, a default of 1.0 is
assumed for that host.
You can obtain relative speed values using the cfx5parhosts utility.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
Configuring ANSYS CFX Parallel
Solver Executable
A solver executable may be explicitly supplied, if necessary. This is usually only required when using Install-
ation Root = none, and is recommended for advanced users only. The following substitutions are made
on the string:
2.1.1.1. Adding Hosts for Parallel Processing with the cfx5parhosts Utility
You can add new hosts to ANSYS CFX's database for parallel runs using the cfx5parhosts utility; this is
done by running:
CFXROOT\bin\cfx5parhosts argument list
where argument list corresponds to one or more of the arguments listed below.
Argument Description
-add host[,host,...] Add information about the named host(s) to the file. This assumes that
ANSYS CFX is installed in the same directory on each listed host as on the
host on which you are running.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Windows Parallel Setup
Argument Description
fill in the Host Architecture String parameter. This is the default behavior. Note
that if the Installation Root parameter is incorrect for the host, it will use the
standard system commands to guess a generic architecture string. This can
happen if you use -add to include a host with a different installation directory
than the local one.
-user Use the per-user host file.
Note
IBM Platform MPI service requires that all hosts are on the same domain and that the user has
an account for that domain.
IBM Platform MPI uses the cpu_bind option by default and binds processes to cores using a
cyclic order. This leads to better performance but, on multi-user clusters having scheduling systems
that do not enforce exclusive use of cluster nodes, this may cause problems because multiple
jobs may be bound to the same CPU on the same node. In this case, the cpu_bind argument
to mpirun should be removed from the IBM Platform MPI start methods in the start_meth-
ods.ccl file in the <CFXROOT>/etc directory.
4. On the Windows Firewall dialog box, click the Exceptions tab and then click Add Program.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
Configuring ANSYS CFX Parallel
The IBM Platform MPI service listens to port 8636 by default. This can be changed during installation
of IBM Platform MPI from the product installer or using the following command:
cfx5parallel -setportkey-pcmpi-service
After each selection, click OK to add that program to the list of programs that are permitted to
pass through the Windows firewall.
6. When you are finished, click OK to close the Windows Firewall dialog box, then close the Windows Se-
curity Center and the Control Panel.
2. Enter:
cfx5parallel -register-impi-user
A prompt will appear asking for a user name which is valid on all machines. This must include a
domain where needed. For example, DOMAIN\User.
A prompt will then appear asking for a password. This must be then entered again for confirmation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Windows Parallel Setup
4. On the Windows Firewall dialog box, click the Exceptions tab and then click Add Program.
<CFXROOT>\bin\<CFX5OS>\solver-impi.exe
<CFXROOT>\bin\<CFX5OS>\double\solver-impi.exe
<CFXROOT>\..\commonfiles\MPI\Intel\<version number>\winx64\bin\smpd.exe
<CFXROOT>\..\commonfiles\MPI\Intel\<version number>\winx64\bin\mpiexec.exe
After each selection, click OK to add that program to the list of programs that are permitted to
pass through the Windows firewall.
6. When you are finished, click OK to close the Windows Firewall dialog box, then close the Windows Se-
curity Center and the Control Panel.
2.4. Setting up and Running Microsoft Windows HPC 2008 or HPC 2012
To set up running Microsoft Windows HPC 2008 or Microsoft Windows HPC 2012, steps must be taken
so that:
The installed software is on a shared location that can be accessed by all hosts
To prepare for running ANSYS CFX with Microsoft Windows HPC 2008 or Microsoft Windows HPC 2012,
you can follow the steps below (terms in angle brackets < > should be replaced with the required entry):
1. Install ANSYS Licensing, ANSYS Workbench and ANSYS CFX on the head node.
2. Share the installation directory. For example, on a typical installation share C:\Program Files\ANSYS
Inc as \\<HeadNodeName>\ANSYS Inc where <HeadNodeName> is the name of the head node.
3. Install the ANSYS prerequisites on all of the cluster nodes. You can do this either by:
or by using the clusrun command on the headnode to execute these commands on all the nodes
(refer to your Microsoft Windows HPC documentation for details).
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
Configuring ANSYS CFX Parallel
4. Share the working directory on the head node. For example, share C:\Users\<UserName> as
\\<HeadNodeName>\<UserName> where <UserName> is the user name.
Alternatively, share the working directory of the submitting machine. For example share
C:\Users\<UserName> on the submitting machine as \\<SubmitHostName>\<UserName>
where <SubmitHostName> is the name of the submitting machine.
5. If the submitting machine is different from the server head node, it is necessary to install HPC Pack 2008
R2 Client Utilities on the submitting machine. This is available for download from Microsoft. This sets the
CCP_HOME environment variable, enabling the Submit to Windows CCS or HPC Queue start method in
the CFX-Solver Manager.
7. Set up ANSYS Workbench for a network as described in Network Installation and Product Configuration.
To submit a job:
1. Start the CFX-Solver Manager (either using CFX standalone or from ANSYS Workbench) on the submitting
machine using the software installed on the headnode.
2. Ensure that the Run Mode on the Run Definition tab of the CFX-Solver Manager is set to Submit to
Windows CCS or HPC Queue. Otherwise, set up the CFX-Solver Manager as normal.
3. Click Start Run on the CFX-Solver Manager to start the simulation. The first time a simulation is run,
supply the required credentials that are prompted (this prompt may appear behind the CFX-Solver Manager
window). You may elect to have these credentials saved to avoid repeated prompting of these credentials.
Note
1. For simulations making use of User Fortran, you must ensure that the Fortran is linked against
the solver-msmpi.lib. This is done by making the appropriate changes to cfx5mkext.ccl.
3. To use on ANSYS Workbench with Parameters and Design Points, start the CFX-Solver Manager
ensure that the Run Mode on the Run Definition tab of the CFX-Solver Manager is set to
Submit to Windows CCS or HPC Queue, set the number of processes, then click Save
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
ANSYS CFX Windows Parallel Setup
Settings. When the user clicks Update all Design Points each parameter or design point will
be solved on the cluster.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
IBM Platform MPI with High (>4096) Process Count
The Platform MPI software included with ANSYS products allows for a maximum of 4096 processes to
be included in a single parallel calculation. You will need to obtain an additional license from Interna-
tional Business Machines Corp. (IBM) for higher process counts. Alternatively, you can use the "Intel
MPI" option in the settings for your parallel calculation.
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
Release 16.2 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.