Structural Design Calc Slide 5
Structural Design Calc Slide 5
Structural Design Calc Slide 5
For Program element review, design calculation was provided included Veranda
beam design and Slab design. More detail design was provided in the visit Phase 2
data.
Following observations are based on phase 2 design calculation.
1. Design calculation labeled as depending on Plan shaped of drawings
2. However design contents of design calculation doesnt represents true picture
regarding Plan shape of building
3. For example generic slab design model is presented with 3 class room
Block Masonry Earthquake Resistance:
No calculation was provided which justify that (load bearing wall are sufficiently
strong to bear EQ loads), instead of only statement was provided in
"This type of structure is sufficient in providing structural stability for gravity loads
as well as safety against earthquakes of low intensities that are likely to occur in
zones 2A & 2B. Our structural design is based on Pakistan Building Code Chapter-5,
Division I-III. All structural elements such as foundations, verandah columns, slabs
and staircase are designed by manual calculations."
Column
Lap splice is provided in mid of column in seismic zone 3 for example Ziarat Talash
"Lap splice permitted only within center half of clear column height".
Beam Splice: