3412C
648 ekW/ 810 kVA/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor
3412C
648 ekW/ 810 kVA
50 Hz/ 1500 rpm/ 400 V
Metric English
Package Performance
Genset Power Rating with Fan @ 0.8 Power Factor 648 ekW
Genset Power Rating 810 kVA
Aftercooler (Separate Circuit) 91.0 C 195.8 F
Fuel Consumption
100% Load with Fan 171.5 L/hr 45.3 gal/hr
75% Load with Fan 130.2 L/hr 34.4 gal/hr
50% Load with Fan 90.7 L/hr 23.9 gal/hr
25% Load with Fan 52.4 L/hr 13.8 gal/hr
Cooling System
Engine Coolant Capacity 58.6 L 15.5 gal
Inlet Air
Combustion Air Inlet Flow Rate 48.8 m/min 1721.4 cfm
Max. Allowable Combustion Air Inlet Temp... N/A N/A
Exhaust System
Exhaust Stack Gas Temperature 539.4 C 1002.9 F
Exhaust Gas Flow Rate 139.1 m/min 4913.4 cfm
Exhaust System Backpressure (Maximum Allowable) 6.7 kPa 27.0 in. water
3412C
648 ekW/ 810 kVA/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor
Heat Rejection
Heat Rejection to Jacket Water 385 kW 21921 Btu/min
Heat Rejection to Exhaust (Total) 636 kW 36184 Btu/min
Heat Rejection to Aftercooler 85 kW 4860 Btu/min
Heat Rejection to Atmosphere from Engine 108 kW 6122 Btu/min
Heat Rejection to Atmosphere from Generator 24 kW 1376 Btu/min
Alternator
Motor Starting Capability @ 30% Voltage Dip 1629 skVA
Current 1169 amps
Frame Size 598
Excitation PM
Temperature Rise 105 C
Emissions (Nominal)
NOx 2972.5 mg/Nm 6.2 g/hp-hr
CO 193.7 mg/Nm 0.4 g/hp-hr
HC 122.3 mg/Nm 0.3 g/hp-hr
PM 45.9 mg/Nm 0.1 g/hp-hr
1. For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing
restriction from factory.
2. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting
characteristics. Generator temperature rise is based on a 40 C ambient per NEMA MG1-32.
3. Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D &
E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of
77 F, 28.42 in HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data
shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based
on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle.
Note: Codes may not be available in all model configurations. Please consult your local Cat Dealer representative for
availability.
3412C
648 ekW/ 810 kVA/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor
PRIME:Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating.
Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1
hour in 12. Overload operation cannot exceed 25 hours per year.
Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions
Fuel Rates are based on fuel oil of 35 API [16 C (60 F)] gravity having an LHV of 42 780 kJ/kg (18,390 Btu/lb) when
used at 29 C (85 F) and weighing 838.9 g/liter (7.001 lbs/U.S. gal.). Additional ratings may be available for specific
customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and