Production Logging Tools 2014
Production Logging Tools 2014
Production Logging Tools 2014
PLT
Tool Specifications
1-3/8 1-11/16
Diameter 1.37 (35 mm) 1.68 (43 mm)
String Length 175.22 (4451 mm) 185.1 (4693 mm)
Pressure Rating 15,000psi (103MPa)
Temperature Rating 350F(175C)
Power 170 Vdc / 174 mA
Output Signal WSTBus
Sensors
Gamma Ray NaI Crystal
CCL Dual Magnet
Pressure Quartz Pressure Sensor
Temperature PT100
NaI Crystal
Density
Am241 5.5GBq (150 mCi) or Cs137 (5 mci)
Holdup Capacitance Probe
Caged Fullbore (4.5 to 9.625)
Flow
Continuous (Jeweled or Bearing)
PRODUCTION LOGGING TOOLS
PLT
Memory System
Memory Specifications
Diameter 1.37 (35 mm) or 1.68 (43 mm)
Pressure Rating 15,000psi (103MPa)
Temperature Rating 350F(175C)
Power 13.5-20 Vdc
Stand-By Current 2mA
Read/Write Current 15-30 mA
Download Rate 4MB/min (supported by computer configurations)
Sampling Rate Sampling rate and sampling interval can be programmed Min.
sampling rate 20ms
Output Signal Max 62 tools (WSTbus)
Capacity 128Mb
Communication Rate 500kbps
Contact:
HOTWELL U.S. HOTWELL Ges.m.b.H
15905 Waverly Drive Oedenburger Strasse 6
Houston, Texas 77032 A-7013 Klingenbach
USA AUSTRIA