6-66545-06 Rev A
Scalar i40 and Scalar i80 Users Guide, 6-66545-06 Rev A, June 2011, Product of U.S.A.
Quantum Corporation provides this publication as is without warranty of any kind, either express or
implied, including but not limited to the implied warranties of merchantability or fitness for a particular
purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
Copyright 2011 by Quantum Corporation. All rights reserved.
Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior
written authorization of Quantum Corporation is prohibited by law and constitutes a punishable
violation of the law.
TRADEMARK STATEMENT
Quantum, the Quantum logo, and Scalar are registered trademarks of Quantum Corporation, registered
in the U.S.A. and other countries.
Preserving the Worlds Most Important Data. Yours., StorageCare, and Vision are trademarks of
Quantum.
LTO and Ultrium are trademarks of HP, IBM, and Quantum in the U.S.A. and other countries. All other
trademarks are the property of their respective companies.
Specifications are subject to change without notice.
Preface xxi
Worldwide End-User Product Warranty . . . . . . . . . . . . . . . xxviii
Chapter 1 Description 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Library Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Robotic System and Barcode Scanner . . . . . . . . . . . . . . . . . . . . 3
Magazines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
System Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Tape Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Control Path Modification. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Support for WORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Licensable Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Capacity on Demand (COD) . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Advanced Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Encryption Key Management . . . . . . . . . . . . . . . . . . . . . . . . . 15
Glossary 361
Index 371
Figure 44 Assembling the Left and Right Rack Mount Shelves . . . . 234
Figure 45 Rail Adapter Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Figure 46 Assembling the Left-Hand Rack Mount Shelf . . . . . . . . . 236
Figure 47 Installing the Rack Mount Shelves . . . . . . . . . . . . . . . . . 238
Figure 48 Tightening the Rack Mount Shelves . . . . . . . . . . . . . . . . 239
Figure 49 Location for Installing the Clip Nut or Cage Nut . . . . . . . 241
Figure 50 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . 242
Figure 51 Securing the Scalar i40 and Scalar i80 in the Rack . . . . . 243
Figure 52 Desktop Kit, Scalar i40 and Scalar i80. . . . . . . . . . . . . . . 245
Figure 53 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . 248
Figure 54 Location of Rubber Feet on Bottom of Library . . . . . . . . 249
Figure 55 Installing side panels . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Figure 56 Installing Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
Figure 57 Bezel Screw Locations on Bottom of Library . . . . . . . . . . 255
Figure 58 Bezel Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Figure 59 Scalar i80 Pull/Push Locations . . . . . . . . . . . . . . . . . . . . . 257
Figure 60 Components to Remove . . . . . . . . . . . . . . . . . . . . . . . . . 261
Figure 61 Removing the Y-tray Restraints. . . . . . . . . . . . . . . . . . . . 262
Figure 62 Restraining the Y-tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Figure 63 Reinstalled Components . . . . . . . . . . . . . . . . . . . . . . . . . 267
Figure 64 Filler Plates Installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Figure 65 Magazine Release Latch Access Holes . . . . . . . . . . . . . . . 273
Figure 66 Proper Orientation (Right-Side Magazine) . . . . . . . . . . . 274
Figure 67 Removing/Installing the Magazine Bezel. . . . . . . . . . . . . 275
Figure 68 Single Power Supply System . . . . . . . . . . . . . . . . . . . . . . 276
Figure 69 Redundant Power Supply System . . . . . . . . . . . . . . . . . . 277
Figure 70 Ethernet Port Locations on the SCB . . . . . . . . . . . . . . . . 281
Figure 71 Acceptable Installation Locations for Full-Height Tape Drives
289
This manual introduces the Quantum Scalar i40 and Scalar i80 and
discusses:
System operations
Configuration
Web and operator panel interface
Installation and replacement
Basic troubleshooting
Audience This manual is written for Scalar i40 and Scalar i80 operators, system
administrators, and field service engineers.
Convention Example
Right side of the system Refers to the right side as you face the
component being described.
Left side of the system Refers to the left side as you face the
component being described.
Product Safety Quantum will not be held liable for damage arising from unauthorized
Statements use of the product. The user assumes all risk in this aspect.
This unit is engineered and manufactured to meet all safety and
regulatory requirements. Be aware that improper use may result in
bodily injury, damage to the equipment, or interference with other
equipment.
The System, Safety, and Regulatory Information Guide is located on the
Scalar i40 and Scalar i80 documentation and training CD.
Related Documents The following Quantum documents are also available for Scalar i40 and
Scalar i80 systems:
Document
No. Document Title
SCSI-2 Specification
The SCSI-2 communications specification is the proposed American
National Standard for information systems, dated March 9, 1990.
Copies may be obtained from:
Global Engineering Documents
15 Inverness Way, East
Englewood, CO 80112
(800) 854-7179 or (303) 397-2740
Technical Publications
To comment on existing documentation send e-mail to:
doc-comments@quantum.com
Worldwide End-User For more information on the Quantum Worldwide End-User Standard
Product Warranty Limited Product Warranty:
http://www.quantum.com/pdf/QuantumWarranty.pdf
This chapter covers the layout and basic functionality of the library,
including:
Overview
Library Components
Standard Features
Licensable Features
Overview
The Scalar i40 and i80 tape libraries automate the retrieval, storage, and
management of tape cartridges. Tape cartridges are stored in the library
and mounted and dismounted from tape drives using firmware running
on the library or software running on the host systems.
See Appendix A, Specifications for library capacity and a list of tape
drives and media supported by the Scalar i40 and Scalar i80 libraries.
Library Components
Front Panel Figure 1 illustrates the features of the operator panel. The picture shows
the Scalar i40, but the features are the same on the Scalar i80. These
features are described in Table 1.
Navigation/selection buttons
Feature Description
Robotic System and The robotic system identifies and moves the cartridges between the
Barcode Scanner storage slots, tape drives, and the I/E station. The robotic arm (picker)
has picker fingers that enable it to grab tape cartridges and move them
into and out of slots and tape drives.
A barcode scanner is attached to the librarys robotic hand. This barcode
scanner automatically identifies the slots and cartridges in the library, if
the cartridges are fitted with acceptable barcode labels.
Each tape cartridge must contain a unique, matching-readable barcode
that the barcode scanner reads during the inventory process. During the
inventory process, the barcode scanner reads the barcode labels on the
tape cartridges and empty slots to identify the types of tape cartridges
that are installed in the library.
Right magazine
Left magazine
Bottom left
magazine
Power Supply The Scalar i40 and Scalar i80 libraries support single power
configurations consisting of a single AC line input and single DC power
supply. The Scalar i80 library supports a redundant power configuration
consisting of a dual AC line input and dual DC power supplies.
If you have a Scalar i80 and are only using one power supply, the power
supply should be installed in the upper power supply slot, and a filler
plate must cover the empty power supply slot (see Figure 5 on page 11).
If you are using redundant power, you can hot add or hot swap a power
supply (power to the library remains on while you add or exchange the
hardware).
The Scalar i40 power supply cannot be installed in a Scalar i80. However,
the Scalar i80 power supply works in either the Scalar i40 or the
Scalar i80.
Warning: The power outlet must be available near the library and
must be easily accessible.
System Control Board The system control board (SCB) contains the library firmware, all
configurable settings, license keys, and SKM TLS certificates. It manages
the entire library, including the operator panel and robot, and is
responsible for running system tests to ensure that the library is
functioning properly. The SCB has two Ethernet ports:
Left port For remote management (Web client)
Right port For service only. In rare cases, you may need to change
the IP address of the port if it conflicts with your library IP address
(see Configuring the Service Port on page 78).
See Figure 4 on page 10 and Figure 5 on page 11 for port locations.
The SCB contains one LED, in addition to two LEDs on each Ethernet
port (for a total of 5 LEDs). For more information, see System Control
Board LEDs on page 322.
For information on removing and replacing the SCB, see Removing and
Replacing the System Control Board on page 279.
Tape Drives Every library configuration must contain at least one tape drive.
See Appendix A, Specifications for a list of tape drives and media
supported by the Scalar i40 and Scalar i80 libraries.
The library supports mixing different tape drive types within the library
and within partitions. For information on how to do this, see Working
With Partitions on page 51.
Tape drives are installed into tape drive slots in the rear of the library. If a
tape drive slot is empty, a filler plate must cover the empty slot (see
Figure 5 on page 11).
SAS tape drives have one status LED. Fibre Channel tape drives contain a
status and a link LED. For more information on tape drive LEDs, see Tape
Drive/Sled LEDs on page 323.
All tape drives contain only one cable connector.
For information on removing and replacing tape drives, see Removing
and Replacing a Tape Drive on page 286.
Power supply
filler plate
Power supply
filler plate
Standard Features
This section describes several features of Scalar i40 and Scalar i80
libraries.
User Interface The operator panel is located on the front of the library and allows you
to work locally on the library via the user interface. The Web client
allows you to view and perform library functions from remote sites and
is accessible through a browser. The operator panel and Web client each
contain a different user interface and functionality.
See Chapter 3, Understanding the User Interface for more information
about the operator panel and the Web client.
Partitions Partitions are virtual sections within a library that present the
appearance of multiple, separate libraries for purposes of file
management, access by multiple users, or dedication to one or more
host applications.
Organizing the library into partitions divides the resources into virtual
sections. If one of the resources is not available due to a failure or other
cause, the other partitions and their assigned components are still
available. Partitions can also be used to control access to portions of the
library by granting permissions to user accounts to access certain
partitions (see Privilege Levels on page 81 and Creating Local User
Accounts on the Web Client on page 82).
For more information on partitions, see Working With Partitions on
page 51.
Control Path The control path tape drive is used to connect a partition to a host
Modification application. Only one tape drive can be selected as the control path at
one time. By default, the first tape drive assigned to a partition is
designated as the control path. In the event that the control path
connection to the host application fails, you can select a new control
path for the partition. See Configuring Control Paths on page 67.
Support for WORM Scalar i40 and Scalar i80 tape libraries support WORM (write once, read
many) technology. WORM allows non-rewriteable and non-erasable
data to be written and provides extra data security by prohibiting
accidental data erasure. The WORM feature is supported whenever you
use WORM cartridges.
Licensable Features
In addition to the standard features, the following additional, licensable
features are available:
Capacity on Demand (COD)
Advanced Reporting - includes custom reports and logs and Control
Path Failover functionality.
Encryption Key Management
For information on how to obtain and install a license key, see Adding or
Upgrading Licensable Features on page 69.
Capacity on Demand All Scalar i40 and Scalar i80 library configurations ship with the
(COD) purchased number of slots pre-activated. After the initial purchase of
your library, you can activate any remaining inactive slots in your library
by purchasing a COD license upgrade.
The Scalar i40 base configuration has 25 slots activated (these slots
comprise the first 5 magazine columns starting from the left front
magazine column going clockwise). You can buy a COD license to
activate the remaining 15 slots.
The Scalar i80 base configuration has 50 slots activated (these slots
comprise the first 5 magazine columns starting from the left front
magazine column going clockwise). You can buy a COD license to
activate the remaining 30 slots.
To see your librarys current configuration and slot availability, open the
Library Configuration Report (choose Reports > Library Configuration
from the Web client).
Advanced Reporting The Advanced Reporting license applies to your entire library, regardless
of library size. This means you only need to purchase the license once. If
you increase the size of your library, your existing license applies to your
new library configuration.
Advanced Reporting provides the following features and reports that
you can configure for viewing and analysis:
Control Path Failover (CPF) - Provides support for configuring the HP
LTO-5 drive for control path failover. When control path failover is used,
one drive is assigned as the primary control path and another drive as
the control path failover (secondary) drive. The control path failover
drive is used whenever the primary control path drive fails or is
inoperable
Reports - Listed below are report names. You can view, configure, send
via e-mail, and save and reuse report configurations as templates. In
addition, you can automatically e-mail any of the reports to designated
recipients at specified, scheduled times.
Drive Resource Utilization ReportProvides tape drive usage
information, showing you which tape drives are working at
optimum capacity and which are under-utilized. This can help you
allocate your tape drive resources properly.
Media Integrity Analysis ReportProvides Tape Alert count for
various combinations of tape drives, tape cartridges, and Tape Alert
flags. This can help you determine if a problem is due to a specific
tape drive or tape cartridge.
Logs - Listed below are available logs:
Media Security Log - Lists media that has been removed from the
library.
Media Usage Log - Lists information on all media that have ever been
in the library.
For information on how to use the advanced reporting features, see
Advanced Reporting on page 111.
Encryption Key The Encryption Key Management (EKM) license enables tape drive
Management transparent encryption using library-managed encryption. The EKM
license applies to the entire library, regardless of how many slots are
licensed. If you increase the number of slots in your library, your existing
license applies to your new library configuration. For more information
about EKM, see Chapter 7, Encryption Key Management.
Choose a location in which to install the library that is as free from dust
as possible. Dust can damage or degrade performance of library
components and media.
Refer to the following sections of this manual for important information
that you need when installing and setting up your library:
Environmental Specifications on page 343
Taking ESD Precautions on page 226
Figure 6 Packaging
Accessory kit
Rail kit
Kit tray
Media labels
Top foam
Bottom foam
Shipping carton
WARNING: Two people are required to safely lift the library out of
its packaging or into a rack.
Caution: Lift the library chassis at the sides. Avoid putting the
weight of the library chassis on the front bezel.
6 Remove the anti-static wrapping from the library. Keep the anti-
static wrapping intact so that you can use it later if needed.
7 Save the packing box, packaging material, and anti-static wrapping
in case you need to move or ship the library in the future.
8 Remove the Y-tray restraint. The Y-tray restraint consists of four (4)
thumbscrews, a plastic sheet, a small metal clip, and underneath
the plastic sheet, an orange restraint tablocated on the top cover
of the library. See Figure 7.
a Unscrew and remove the four thumbscrews from the top cover
(see Figure 7). Save the thumbscrews in case you need to move
or ship the library in the future.
b Remove the plastic sheet and metal clip and discard. You will
not need to use them again.
c Remove the orange shipping restraint tab and discard. You will
not need to use it again.
9 Once you remove the Y-tray restraint, you may cover the holes in the
library top cover with stickers, which are provided in the accessory
kit for this purpose. This step is optional and is intended to prevent
small objects from accidentally falling into the library through the
holes.
10 Remove the protective plastic sheet covering the front panel display.
The user interface for the Scalar i40 and Scalar i80 libraries is available in
two formats: the operator panel and the Web client. Operations on the
library can be performed locally on the operator panel or remotely on
your computer using the Web client.
Both the operator panel and the Web client are required to operate the
library. Some functionality is only available through the Web client, and
some functionality is only available through the operator panel.
However, it is recommended that you use the Web client rather than the
operator panel to perform most library operations.
This chapter covers:
Operator Panel
Web Client
Menu Trees
Operator Panel
The operator panel is located on the front panel of the physical library.
The operator panel screen contains a menu bar with operations that
correspond to the four physical buttons below it. The menu operations
and button functions change with each screen.
Operator Panel Layout You can choose your desired operator panel home screen that displays
and Functions on the local user interfacethe default home screen or the alternate
home screen that allows easy I/E unlock access. Figure 8 and Figure 9
depict these screen options; Table 2 describes the operator panel
functions.
Title bar
Active display
Menu bar
Navigation/selection
buttons
You can choose to change the view of the home screen for easy I/E
unlock access. Refer to Changing Operator Panel Home Screen View on
page 109.
Scalar i40
Number of occupied
I /E slots
Number of configured
I /E slots
Scalar i80
Number of occupied
I /E slots
Number of
configured I/E slots
Operator Panel
Element Description
Operator Panel
Element Description
Navigating and Editing You use the four navigation/selection buttons exclusively to move
on the Operator Panel through the menus and commands on the operator panel.
From the default home screen, the menu bar lists the four main menu
headings. From the alternate home screen, you can select Menu to
return to the default home screen to access the four main menu
headings.
Press the button corresponding to a menu item to bring up the list of
sub-menu items. The item you are currently on is highlighted. Press the
buttons corresponding to Up, Down, Left, or Right to navigate to a
desired menu item. As you move through the items, the highlighting
moves with you so you always know which item you are on. Press the
button corresponding to Select to select a highlighted item or action.
This in turn brings up either another sub-menu, a screen where you can
modify settings or perform operations, or a screen displaying
information.
To edit a modifiable field, such as date, time, licenses, IP address, and so
on, use the Left and Right buttons to move through the field, one
segment at a time (for license keys and passwords, you will move one
digit or letter at a time). Use the Up and Down buttons to change the
value of each segment. When you reach the value you want, press the
Right button. As you press Right, the value fills in and you go to the
next segment. To edit a previous entry, press the Left button until you
reach the entry and edit as before. For multiple fields, continue to press
Right after each entry until you reach the last entry. At this point, the
Right button designation changes to Apply. Press the Apply button.
The new information displays. Press Exit to exit. For an example, see
Figure 10 on page 28.
To scroll through a list of items, or to edit letters and numbers, you can
press the appropriate button repeatedly to scroll one item at a time, or
you can hold the button down for fast scrolling through the available
options.
To exit a screen, press the Exit button.
To cancel an operation without saving any changes, press the Cancel
button. If you are in the middle of making changes, repeatedly press the
Left button until you are back at the first field on the screen, then press
the Cancel button.
Web Client
The Web client interface is accessible from supported Web browsers (see
Supported Internet Browsers on page 347).
To access the library from a remote location, the library must be
connected to your network via an Ethernet connection. Simply enter the
librarys IP address in your Internet browser bar to access the Web client.
See Configuring Network Settings on page 40 for information on
setting the network configuration settings for remote use.
Tips Keep the following tips in mind when using the Web client:
You must disable Web browser popup blockers to use the Web
client interface and the librarys online Help. Add the Scalar i40 or
Scalar i80s Internet Protocol (IP) address to the list of trusted/
allowed sites on your Scalar i40- or Scalar i80-supported browser, so
the Web client pages will automatically refresh.
Do not use your Internet browser Back button to navigate the Web
client pages. Instead, use the buttons provided within the Web
client.
Sorting Information in You can sort information displayed in tables if the table column heading
Tables is bold. Click the column heading and the information will sort. Click
again to toggle from ascending to descending.
Web Client Layout and Figure 11 on page 30 shows the Web client interface. Table 3 on
Functions page 31 explains the Web client interface elements.
Header
Menu bar
Active
display
Web Client Home Page The home page displays status and health information in the active
display portion of the window (see Figure 11 on page 30). See System
Summary and Subsystem Status below for more information.
System Summary The system summary is available on the home page of the Web client.
Subsystem Status You can quickly gauge the health of the library by observing the color of
the three subsystem status buttons located at the bottom of the home
page. These buttons provide quick access to information about the
health of the library for faster recovery if problems occur. You can
select the buttons to view diagnostic tickets that report problems in the
subsystems.
The three subsystems are:
Library Represents connectivity, control, cooling, power, and
robotics.
Drives Represents tape drive components, such as tape drives,
tape drive firmware, and tape drive sleds.
Media Represents media components, such as cartridges and
barcode labels.
Each button has three states indicated by color. The three states are:
Green (check mark) No diagnostic tickets exist, or, if any tickets
do exist, they have all been closed.
Yellow (exclamation point) The library contains open or
unopened, low- or high-priority diagnostic tickets.
Red (X mark) The library contains open or unopened urgent
diagnostic tickets.
If the color of a subsystem button is red or yellow, you can click the
button to display the corresponding Diagnostic Tickets screen. This
screen lists library, drives, or media tickets, depending on which button
was selected. See About Diagnostic Tickets on page 312 for more
information.
Menu Trees
The following menus organize operations and commands into logical
groupings:
The Setup menu consists of commands that users with
administrator privileges can use to set up and configure various
aspects of the library, including partitions, I/E station slots, cleaning
slots, control paths, network settings, drive settings, users,
notifications, date and time, licenses, library registration, and e-
mail.
The Operations/Actions menu consists of commands that enable
users to change the librarys mode of operations, import and export
cartridges, load and unload tape drives, move media, lock or unlock
the I/E station, log out, and shut the library down. The menu is
called Actions on the operator panel and Operations on the Web
client.
The Tools menu consists of commands that you can use to maintain
your library such as viewing diagnostic tickets, generating
diagnostic logs, identifying drives, configuring the internal network,
saving and restoring the library configuration, setting system and
security settings, and updating firmware, and performing library
diagnostics.
The Reports menu provides various kinds of library information.
Administrators have access to all menu commands, but users privileges
are more limited.
Figure 12 lists the operator panel menus. Figure 13 lists the Web client
menus.
Auto DT Close
Security Services
Network IF
SSH Services
ICMP
Web client
Service User
SNMP V1/V2
SSL
Web Client
Main Menu Bar
Save/Restore
Cleaning Slots Import Network Settings
Configuration
E-mail Configuration
I/E Station Slots Export Logged In Users
Record
Drive Resource
Notification Partitions EKM Path Diagnostics
Utilization
Import Communication
Advanced Reporting Drive About
Certificates
Receiver
Addresses Load Encryption Certificate Scalar i40/i80
System Shutdown
Retrieve SKM Logs
Network
Drives
User Accounts
Robotics
Remote Authentication
Encryption
System Configuration
Partition Configuration
Register Library
Note: Power cycling (powering the library on and off) is not necessary
to configure the library.
Operator Panel
The Setup Wizard on the operator panel is covered in detail in the
Scalar i40 and Scalar i80 Quick Start Guide.
Web Client
To access the Setup Wizard, click Setup > Setup Wizard. Work through
several screens that enable you to add licenses; set date, time, and time
zone; configure cleaning slots; configure I/E station slots; and auto-
create partitions.
Default Configuration
The library comes with a default configuration, which you can modify at
any time. The default configuration is as follows:
Note: Make sure that the library is connected to the network before
modifying network settings. If the Ethernet cable is not
installed properly, you cannot configure the network settings.
Install one end of the Ethernet cable in the left-most Ethernet
port of the system control board (SCB) located on the back of
the library (see Figure 4 or Figure 5 on page 11). Make sure the
other end of the Ethernet cable is installed in the appropriate
LAN port on your LAN.
Library Host Name The host name is the network name you want to assign to the library.
The host name is limited to 12 lowercase alphanumeric characters and
dashes (-).
You can view, but not modify, the host name on the operator panel. To
modify the host name, you must use the Web client.
Web Client
1 Select Setup > Network Management > Network.
2 Type a name in the Host Name field, and click Apply.
DHCP DHCP is enabled by default. When DHCP is enabled, the library obtains
an IP address automatically. If DHCP is disabled, you must manually
enter an IP address, default gateway, and subnet mask/net prefix. You
can enable/disable DHCP from the operator panel or Web client.
Operator Panel
Select Setup > Network Configuration.
Web Client
Select Setup > Network Management > Network.
IP Addresses The library can support both IPv4 and IPv6 network settings at the same
time. For more details, see the bullets below.
Operator Panel
1 Select Setup > Network Configuration.
2 Modify the IP address using the method described in Navigating
and Editing on the Operator Panel on page 27.
Web Client
Select Setup > Network Management > Network.
Operator Panel
1 Select Setup > Network Configuration.
2 Modify the fields using the method described in Navigating and
Editing on the Operator Panel on page 27.
Web Client
Select Setup > Network Management > Network.
Registering External Administrators can register transport protocols, IP addresses, and port
Management numbers of external management applications to enable them to
Applications receive SNMP traps from the library. (By default, the library ignores all
SNMP SET operations, so external management applications cannot
register themselves to receive SNMP traps from the library.)
After registering the transport protocols, IP addresses, and
corresponding port numbers, you can perform a test to verify that the
library can send the SNMP traps to the addresses.
Web Client
1 Select Setup > Network Management > SNMP Trap
Registrations.
2 Click one of the following buttons to perform these actions:
Create Adds the IP address and port number of the external
application to the list of registered addresses that will be sent
SNMP traps.
Delete Deletes a selected IP address and port number.
Test This test simply sends the traps; it does not check to see
if they were received. You must check the external management
applications to verify that the traps were received.
Enabling SNMP The library supports SNMP v1, v2c, and v3.
Versions You can enable or disable support for SNMP v1 and v2c. They are
enabled by default. The recommended practice is to disable SNMP v1
and SNMP v2c in highly secure environments.
SNMP v3 is always enabled and cannot be disabled.
The authentication algorithm is set to MD5, and the encryption is
disabled system-wide.
Operator Panel
1 Select Setup > Security Services > SNMP V1/V2
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Press Exit.
Web Client
1 Select Setup > Network Management > SNMP.
2 Select the SNMP V1 and V2c check box (under New Settings) to
enable SNMP v1 and v2c. Clear the SNMP V1 and V2c check box to
disable SNMP v1 and v2c.
Enabling SNMP The library allows you to enable or disable SNMP authentication traps.
Authentication Traps When the library receives an SNMP message that does not contain the
correct community string or other authentication information, the
library sends an SNMP authentication trap message to the external
management application, indicating the authentication failure. SNMP
authentication traps are disabled by default.
Web Client
1 Select Setup > Network Management > SNMP.
2 Select the SNMP Authentication Traps check box (under New
Settings) to enable SNMP authentication traps. Clear the SNMP
Authentication Traps check box to disable SNMP authentication
traps.
Modifying the SNMP Administrators can modify the SNMP community string. The SNMP
Community String community string is a text string that acts as a password to authenticate
GET and GET-NEXT SNMP v1 and SNMP v2c messages exchanged
between the library and an external management application. The
SNMP community string used by the library must match the string used
by the external management application.
The default SNMP community string on the library is: publicCmtyStr.
For security purposes, this string should be modified. When modifying
the community string, adhere to the following guidelines: the
community string is case-sensitive, cannot be empty, and cannot exceed
32 characters.
You can modify the SNMP community string from the Web client only.
Web Client
1 Select Setup > Network Management > SNMP.
2 Enter a new community string in the SNMP Community text box
under New Settings.
3 Click Apply.
Downloading the SNMP The SNMP Management Information Base (MIB) is for library customers,
MIB partners, third-party management software developers, and other
parties interested in integrating the Scalar i40 and Scalar i80 with
commercial management frameworks. The Scalar i40 and Scalar i80
libraries support SNMP by publishing a MIB that can be queried to
obtain the status of the library and many of its individual components.
Administrators can download the SNMP MIB from the library. The MIB
can then be installed on an SNMP external management application.
For more information about the library MIB, see the Scalar i40 and
Scalar i80 Basic SNMP Reference Guide (6-66773-xx) or contact
Quantum Support.
For information on integrating MIBs with an SNMP management
application, contact your network management application vendor.
Web Client
1 Select Tools > Download SNMP MIB.
2 Save the file to a known location.
Setting the Date and Date and time settings are used to log the date and time events take
Time Manually place and to set the time for automatic backup and restore functions. At
a minimum, you should set the librarys date and time as part of the
initial library configuration.
The time is set to a 24 hour clock. For example, four oclock in the
afternoon is entered as 16:00.
Operator Panel
1 Select Setup > Date & Time.
2 Modify the date and time using the method described in Navigating
and Editing on the Operator Panel on page 27.
Web Client
1 Select Setup > Date & Time.
2 Refer to the library Web client online help for detailed instructions.
To view the help, click the Help icon in the upper right corner of the
screen.
Setting the Date and The library supports the Network Time Protocol (NTP). NTP allows you to
Time Using the Network synchronize the library date and time with other components in your IT
Time Protocol infrastructure. Administrators can either modify the date and time zone
settings manually or configure NTP.
If NTP is enabled, the time zone and IP addresses (or host names, if DNS
is configured) of at least one NTP server must be configured on the
library. Contact your network administrator for NTP server IP address
information.
Web Client
1 Select Setup > Date & Time.
2 Refer to the library Web client online help for detailed instructions.
To view the help, click the Help icon in the upper right corner of the
screen.
Setting the Time Zone To select your time zone from a list, disable Use Custom Time Zone
setting and select your time zone from the list.
If your time zone does not appear on the list, or if you want more
control over your time settings, enable Use Custom Time Zone and set
a Universal Coordinated Time (UTC) offset.
You can only set the time zone via the Web client.
Web Client
1 Select Setup > Date & Time.
2 Refer to the library Web client online help for detailed instructions.
To view the help, click the Help icon in the upper right corner of the
screen.
Setting Daylight Saving If you selected your time zone from the drop-down list (see Setting the
Time Time Zone on page 50), the library automatically adjusts for daylight
saving time. There is no need to manually reset the clock for time
changes.
However, if you set a custom time zone, the library will not
automatically adjust for daylight saving time. You must enable the Use
Custom Daylight Saving Time setting. Once enabled, you can set start
and stop times to an accuracy of one minute.
You can only set daylight saving time on the Web client.
Web Client
1 Select Setup > Date & Time.
2 Refer to the library Web client online help for detailed instructions.
To view the help, click the Help icon in the upper right corner of the
screen.
Operator Panel
1 Select Setup > Configure Partitions > Auto-Create Partitions.
2 Use the Up and Down buttons to select the number of partitions
you want to create. (If the Up and Down buttons are not available,
you do not have available resources. Modify or delete partitions to
create resources.)
3 Press Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Partitions.
2 Click Automatic. (If the Automatic button is not visible, you do not
have available resources. Modify or delete partitions to create
resources.)
The Automatically Create Partitions screen displays.
By default, the library applies the Scalar i40-i80 library emulation
type and Standard media barcode format to each partition. You can
change these settings by modifying the partition after it has been
created (see Modifying Partitions on page 56).
3 Using the Partitions drop-down list, select the number of partitions
to create.
4 Click Apply.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Manually Creating You can manually create partitions any time after the initial
Partitions configuration of the library. The maximum number of partitions that can
be created is equal to the number of tape drives in the library.
The library must contain at least one unallocated tape drive and one
unallocated slot to manually create a partition. If no unallocated tape
drives or slots exist, you must modify or delete partitions to free
resources. For more information, see Modifying Partitions on page 56
and Deleting Partitions on page 57.
When the library creates partitions, it assigns the first tape drive in the
partition as the control path. You can change the control paths at any
time. See Configuring Control Paths on page 67 more information.
Before creating partitions, verify that all tape drives are unloaded and
that all cartridges are in their appropriate storage slots. For information
on unloading tape drives, see Unloading Tape Drives on page 161.
You can create partitions manually only on the Web client.
Web Client
1 Select Setup > Partitions.
2 Click Manual.
3 Type a name to describe the new partition into the Enter Name text
box.
4 Select one of the following emulation types from the Emulation
Type drop-down list:
Scalar i40-i80 (default)
ADIC Scalar i500
Quantum Scalar i500
Quantum Scalar i2000
ADIC Scalar i2000
5 Select one of the following media barcode formats (for reporting to
host) from the Set Media Barcode Format drop-down list:
Standard Six Six character barcode number with or without
a one or two-character media ID; for example, XXXXXX
orXXXXXXL4. Only the six character barcode is reported to the
host.
Plus Six Six character barcode number followed by a media
ID; for example, XXXXXXL3. Six character barcode and media
ID are reported to the host.
Modifying Partitions You can modify partition settings any time after a partition is created.
For example, you can modify the name, emulation type, media barcode
format, and number of assigned tape drives and slots.
The library automatically takes the partition offline before modifying it
and places it back online after it has been modified.
The tape drive set as the control path for a particular partition cannot be
deleted from that partition. The check box associated with the control
path is grayed out. For more information on setting the control path,
see Configuring Control Paths on page 67.
Before modifying partitions, verify that all tape drives are unloaded and
that all cartridges are in their appropriate storage slot location. For
information on unloading tape drives, see Unloading Tape Drives on
page 161.
You can modify partitions only on the Web client.
Web Client
1 Select Setup > Partitions.
2 Select a partition and click Modify.
3 Modify any of the settings. For a description of what each setting
means, see Manually Creating Partitions on page 54.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Deleting Partitions A partition can be deleted when it is no longer needed. After a partition
is deleted, its resources (tape drives and slots) become unassigned and
can be used to create new partitions or added to existing partitions.
Before deleting a partition, unload cartridges from the tape drives
within the partition and then export all cartridges from the partition.
Remove the cartridges from the I/E station after exporting them. For
information on unloading tape drives, see Unloading Tape Drives on
page 161. For information on exporting cartridges, see Exporting Tape
Cartridges on page 158s. You can also remove cartridges by releasing
the magazine and removing them by hand (see Releasing Magazines on
page 148). If you do this, be sure to only remove cartridges assigned to
that partition (see Viewing the Library Configuration Report on
page 210).
After a partition is deleted, its resources (for example, tape drives and
slots) become available and can be reassigned to new or existing
partitions.
You can delete partitions on both the operator panel and the Web
client.
Operator Panel
1 Select Setup > Configure Partitions > Delete Partition.
2 If more than one partition is configured on the library, use the Up
and Down buttons to select a partition from the list.
3 Press Delete.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Partitions.
2 Select a partition and click Delete.
3 Save the library configuration (see Saving the Library Configuration
on page 107).
Viewing the Current You can view basic details about all of your partitions, including online/
Partitions offline status, control path tape drive, number of tape drives in the
partition, number of storage slots, and number of I/E station slots
available to the partition.
Operator Panel
1 Select Reports > Partitions (alternatively, select Setup >
Configure Partitions > View Current Partitions).
2 If more than one partition is configured on the library, select a
partition and press Select.
Web Client
You can view partition information in several places:
Library home page (see Web Client Home Page on page 31)
Library configuration report (see Viewing the Library Configuration
Report on page 210).
Partition modification screen (select Setup > Configure Partitions,
select a partition, and click Modify).
Changing Access to An administrator can control which partitions a specified user can
Partitions access by modifying the users account on the Web client. For more
information, see Working With Local User Accounts and Passwords on
page 79.
Web Client
Select Setup > User Management > User Accounts.
Taking a Partition There are two partition modes: online and offline.
Online or Offline Online SCSI hosts control the partition. In this mode, all host
application SCSI commands are processed.
Offline SCSI hosts cannot control the partition. In this mode,
library operations can be performed via the local or remote user
interface.
When you are changing the partition mode, be aware of the following:
When you access the Change Partition Mode screen, you will see
only partitions to which you have been given access.
When changing the partition mode from online to offline, all host
application commands in progress at the start of the mode change
are completed.
You can change partition modes from the operator panel or the Web
client.
Operator Panel
1 Select Actions > Change Partition Mode.
The partitions are displayed, along with their online/offline status.
2 If more than one partition is configured on the library, use the Up
and Down buttons to select a partition.
3 Press Modify.
4 Uses the Up and Down buttons to change the mode.
5 Press Apply.
Web Client
1 Select Operations > Partitions > Change Mode.
In the partition table under Mode, the Current column indicates
the current mode of the partition. The New column contains an
Online/Offline button. The button toggles between modes.
Note: If the library contains zero import/export (I/E) station slots, you
will not be able to import or export cleaning cartridges. See
Configuring I/E Station Slots on page 63 for more information.
Operator Panel
1 Select Setup > Dedicated Slots > Cleaning.
2 Press Modify.
3 Use the Up and Down buttons to select a value from zero to 4.
4 Press Apply.
5 Press Exit.
6 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Cleaning Slots.
2 Under the New Settings column, select the number of cleaning
slots to configure.
3 Click Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
20 Right top 20
25 Right top 20
Right bottom front 5
40 Right top 20
Right bottom 20
You can configure zero I/E station slots. However, configuring zero I/E
station slots has the following consequences:
You cannot import and export data or cleaning cartridges using I/E
stations.
You cannot manually clean tape drives with a cleaning cartridge
using the operator panel.
You will need to bulk load and bulk unload cartridges, disrupting
library operations (see Bulk Loading Tape Cartridges on page 155).
Note: Before using the I/E station to load and unload cartridges, you
need to unlock the I/E station, which allows you to slide the
magazine out just far enough to access the I/E station slots (see
Unlocking and Opening the I/E Station on page 145).
Operator Panel
1 Select Setup > Dedicated Slots > I/E.
2 Press Modify.
3 Use the Up and Down buttons to select a value.
4 Press Apply.
5 Press Exit.
6 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > I/E Station Slots.
The I/E Station Configuration screen displays. The Current
Settings column lists the number of I/E station slots that are
currently configured.
2 Under the New Settings column, select the number of I/E station
slots to configure.
3 Click Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Operator Panel
1 Select Setup > Tape Drives (FC).
2 If more than one Fibre Channel tape drive is installed, use the Up
and Down buttons to select a tape drive and press Select.
3 Use the Up and Down buttons to select the item to configure
(Speed, Topology, or Loop ID) and press Modify.
4 Use the Up and Down buttons to scroll through the list of options
until you reach the one you want, then press Apply.
5 Continue to modify as above. When finished, press Exit.
6 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Drive Settings.
2 View the SAS tape drive settings, if desired.
3 Make changes to any of the Fibre Channel tape drive settings by
using the drop-down lists to select new values.
4 Click Apply.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Only one tape drive can be selected as the control path per partition. In
the event that the tape drive control path connection to the host
application fails, you can manually select a different control path tape
drive for the partition.
You can only configure control paths via the Web client.
Web Client
1 Select Setup > Control Path.
2 If more than one partition exists, select a partition and click Next.
3 To select a new control path for the partition, select a tape drive
from the list of tape drives.
4 To delete the control path for the partition, locate the tape drive
that is currently selected as the control path and clear the selection.
5 Click Apply.
6 Save the library configuration (see Saving the Library Configuration
on page 107).
Note: You can configure a control path failover drive if you have an
Advanced Reporting license and HP LTO5 tape drives. See
Working with Control Path Failover (CPF) on page 113
If you replace the SCB: The SCB contains information about your
library configuration. If you replace your SCB, you must reinstall your
license key(s) onto the library. You may be able to reinstall them yourself
if you have saved the license keys or can retrieve them from the Web
sites listed above. In some cases, factory installed license keys will not be
listed on the Web site and you will need to contact Quantum Support
for a replacement. If you cannot retrieve your license keys or need
assistance, contact Quantum Support.
Viewing Your License To see the licenses you have purchased and obtained, go to the
Keys following Web site: http://www.quantum.com/licensekeys. The license
history for each feature is listed (feature licensed, authorization code,
and date license key was obtained).
Viewing Installed To see which licenses are installed on your library, go to the following
Licenses screens:
Operator Panel
Select either of the following
Reports > Licenses
Setup > License Installation
Web Client
Select Setup > License.
Obtaining a License Key To obtain your license key for a new feature or upgrade:
1 Contact your Quantum technical sales representative to submit your
order for the feature or upgrade.
2 Upon receipt of your order, Quantum will mail you a license key
certificate containing your authorization code.
3 On your library, locate the serial number. You will need the serial
number to retrieve your license key from the Web site. To locate the
serial number:
On the operator panel, select Reports > About Library.
On the Web client, select Reports > About > Scalar i40/i80.
4 Access the License Key Management Web site: http://
www.quantum.com/licensekeys.
5 Enter the information requested on the screen to obtain your license
key.
You are now ready to apply the license key to the library. See Applying a
License Key on page 71.
Applying a License Key Once purchased, you can apply a license key to the library.
Operator Panel
Web Client
1 From the Web client, select Setup > License.
2 Type the new license key in the Enter New License Key text box.
3 Click Apply.
4 Refresh your Internet browser. Adding a license can sometimes
affect menu display. Refreshing the browser updates all the menus.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Creating E-mail Administrators can create e-mail notifications. The library supports a
Notifications maximum of 20 e-mail notification recipients, including the default
support e-mail notification. Each e-mail notification recipient must have
a unique e-mail address.
To set e-mail notifications, you need to provide the e-mail address and
filter level setting for the recipient. For more information on filter levels,
see Working With E-mail Notifications on page 72.
Each e-mail notification includes an optional Comments text box you
can use to enter important system configuration details, such as the
network environment or third-party software applications that interface
with the library. Such information can help technical support personnel
to troubleshoot the library.
You can create e-mail notifications on the Web client only.
Web Client
1 Select Setup > Notification > Setup.
The Setup - System E-mail Notifications screen displays. The
screen lists all e-mail notifications that have been created.
2 Click Create.
The Create System E-mail Notification screen displays.
3 In the Select Filter Level drop-down list, select the filter level to
assign to the e-mail notification. For more information on filter
levels, see Working With E-mail Notifications on page 72.
4 In the Enter E-mail Address text box, type the e-mail address that
you want to receive e-mail notifications.
Note: Do not enter more than one e-mail address in the Enter
E-mail Address text box. If you need to send e-mail
notifications to multiple e-mail addresses, create an e-mail
notification for each e-mail address.
6 Click Apply.
7 Save the library configuration (see Saving the Library Configuration
on page 107).
Modifying E-mail Administrators can modify existing e-mail notification settings at any
Notifications time after the e-mail notification is created.
Web Client
1 Select Setup > Notification > Setup.
The Setup - System E-mail Notifications screen displays. The
screen lists all the e-mail notifications that have been created.
2 Select an address to modify, and click Modify.
The Modify System E-mail Notification screen displays.
3 Modify any of the following settings:
Under the New Settings column, select the Enabled check box
to enable e-mail notification. Clear the Enabled check box to
disable e-mail notification.
Under the New Settings column, select a new filter level from
the Filter Level drop-down list. For more information on filter
levels, see Working With E-mail Notifications on page 72.
In the E-mail Address text box, type a new e-mail address.
In the E-mail Comment text box, type a new comment.
4 Click Apply.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Notification > Setup.
2 Select an e-mail notification and click Delete.
A confirmation dialog box displays.
3 Click OK.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Note: You may use a host name for the SMTP server instead of an IP
address only if the library is set up to use Domain Name System
(DNS) servers. See Default Gateway, Subnet Mask, Network
Prefix, and DNS Addresses on page 43 for more information.
After configuring the e-mail account, you can send a test message to an
e-mail address to verify that the account is configured properly.
You must have administrator privileges to configure the e-mail account.
You can configure the library e-mail account from the Web client only.
Web Client
1 Select Setup > Notification > E-mail Account.
The Setup - E-mail Account screen displays.
2 In the SMTP server text box, type the IP address or host name of the
SMTP server.
3 In the Sender e-mail address text box, type an e-mail address for
the SMTP server (for example, scalar_i40@mycompany.com). The
sender address indicates the originator of the e-mail message.
4 For Send snapshot with e-mail notifications, do one of the
following:
To attach a library snapshot file to e-mail notifications, select the
check box.
To not attach a library snapshot file to e-mail notifications, clear
the check box.
Web Client
1 Select Setup > Notification > Contact Information.
2 Enter or modify any of the information in the following text boxes:
First Name
Last Name
Company Name
Phone Number
E-mail Address
System Description
3 Click Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Operator Panel
1 Select Tools > Service Network.
Under Modify Subnet the three-digit octet of the IP address is
highlighted.
2 Use the Up and Down buttons to scroll to the desired subnet, and
press Apply.
For more information on scrolling, see Navigating and Editing on
the Operator Panel on page 27).
Note:
3 Press OK.
Using the Web Client The library ships with a default administrator account for use on the
Default Administrator Web client. The default administrator account has the following
Account settings:
User name: admin
Password: password.
The first time you access the library via the Web client, when you see the
Login screen, type admin in the User name text box and type password in
the Password text box. As soon as you complete the initial library setup,
you should change the password on the default administrator account.
For information on changing passwords, see Modifying Local User
Accounts on the Web Client on page 83.
Privilege Levels Privilege levels are manually assigned to user accounts created within
the library. Controlling access to screens and operations within the
library preserves the integrity of the library and the data that is stored in
it.
Note: If passwords are not enabled on the operator panel, all users
have access to all privileges. See Enabling and Creating
Passwords on the Operator Panel on page 84.
Three types of users are defined in Scalar i40 and Scalar i80 libraries:
Administrators have access to the entire physical library and all of
its partitions. The library ships with a default administrator account.
The user name for the default administrator account is admin and
the password is password. You cannot modify or delete the user
name for the default administrator account, but you can modify the
password. If you misplace the password for the default
administrator account, contact Quantum Support.
For security purposes, an administrator can prevent a service user
from logging on to the library remotely, from either the Web client
or over the Ethernet service port. The service user will still be able to
log in to the library from the operator panel interface. For more
information, see Remote Service Login on page 105.
Creating Local User During or after the initial configuration, you can use the default
Accounts on the Web administrator account to create additional local user accounts, including
Client other accounts with administrator privileges. These administrators can
themselves create other local administrator and user accounts. Users
without administrator privileges cannot create user accounts. The library
can contain a total of eighteen user/administrator accounts, including
the default administrator account.
Web Client
1 Select Setup > User Management > User Accounts.
2 Click Create.
The Create User Account screen displays.
3 Enter User Name - Type a name for the local user account. User
names are limited to 112 lower-case letters, numbers, and
underscores (_). For example: john_usa.
4 Enter Password - Type a password for the local user account.
Passwords are limited to 616 lower-case alphanumeric characters
and can also include underscores (_), periods (.), hyphens (-),
asterisks (*), and the at symbol (@). For example: pass_19.
5 Confirm Password - Retype the password.
Modifying Local User After a local user account has been created, administrators can modify
Accounts on the Web the account settings, such as the password, privilege level, and partition
Client access. You cannot modify the user name. Instead, you will need to
delete the user account and create a new one (see Deleting Local User
Accounts on the Web Client on page 84).
Web Client
1 Select Setup > User Management > User Accounts.
The Setup - Users screen displays.
2 Select a user account and click Modify.
The Modify User Account screen displays, where User Name is the
name of the local user account.
3 Enter your Admin password to verify you have privileges to modify
the account.
4 Enter new password for selected user name: - Optionally, type a
new password. Passwords are limited to 616 lower-case
alphanumeric characters and can include also include underscores
(_), periods (.), hyphens (-), asterisks (*), and the at symbol (@).
For example: pass_19.
5 Confirm new password for selected user name:- Retype the
password.
6 Select Privilege:- Optionally, change privilege level.
7 If the user account has user privileges and you want to modify
partition access, click Next.
The Modify User Account - User Name screen displays, where User
Name is the name of the user account. This screen lists all library
partitions, with the users assigned partitions checked.
8 Modify any of the partition selections.
9 Click Apply.
10 Save the library configuration (see Saving the Library Configuration
on page 107).
Deleting Local User Administrators can delete other local administrator and user accounts
Accounts on the Web when they are no longer needed.
Client
Note: You cannot delete the default administrator account.
Web Client
1 Select Setup > User Management > User Accounts.
The Setup - Users screen displays.
2 Select a user account and click Delete.
A confirmation dialog box displays.
3 Click OK.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Enabling and Creating If you do not set passwords on the operator panel, all users will have
Passwords on the access to all functions, including administrator and service functions. If
Operator Panel you want to restrict access to some users, you must set passwords on
the operator panel.
admin Administrator
user User
Operator Panel
You start out by creating the admin account password. Once created,
you are logged out and need to log back in using the admin password.
Then you can create the user account password.
1 Select Setup > Account Settings > Password Settings.
Admin Password is highlighted.
2 Press Modify.
Disabled is now highlighted.
3 Press the Up button to change the setting to Enabled.
4 Press Apply.
5 You are prompted to create the password. The password is a 4-digit
code (no letters or other characters). The first digit of the code is
highlighted. Use the Up and Down buttons to select a number for
the first digit, then press Right to go to the second digit. As you
move off the digit you created, it displays as a # symbol so that only
the digit you are working on displays actual numbers. If you need to
view or change a digit, press the Left button.
6 When you are finished creating the admin password, press Right
until the Validate Password prompt appears. Re-enter the
password the same way you created it. When finished, press Apply.
A confirmation screen displays.
7 Press OK.
The library logs the session out and the operator panel displays the
login screen, with the User ID of admin highlighted.
8 Press Apply to go to the password line.
9 Using the directional buttons, enter the admin password you
created and press Apply.
10 Select Setup > Account Settings > Password Settings.
11 Press the Down button to highlight User Password and press
Modify.
Disabled is highlighted.
12 Press the Up button to change the setting to Enabled.
13 Press Apply.
14 Create and validate the user password the same way you created
the admin password above.
15 Save the library configuration (see Saving the Library Configuration
on page 107).
Disabling Passwords on If you no longer want to use passwords on the operator panel, you can
the Operator Panel disable them. Once you disable the admin password, the user password
is also automatically disabled. You can only do this on the operator
panel.
Operator Panel
1 Select Setup > Account Settings > Password Settings.
Admin Password is highlighted.
2 Press Modify to modify the Admin password.
Enabled is now highlighted.
3 Press the Down button to change the setting to Disabled.
4 Press Apply.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Modifying Passwords Once passwords are created, you can modify them.
on the Operator Panel
Operator Panel
1 Select Setup > Account Settings > Modify Password.
2 Use the Up and Down buttons to select admin or user.
3 Press Apply.
4 Enter the current password and press Apply.
5 Enter a new password and press Apply.
6 Re-enter the new password to validate it and press Apply.
7 Save the library configuration (see Saving the Library Configuration
on page 107).
Resetting Passwords on If you forget your operator panel passwords and cannot log in, you
the Operator Panel must reset the passwords. Resetting the passwords disables them and
deletes both the admin and user passwords. This means that no login is
required to access the operator panel. You can re-create the passwords
again as needed.
You can only reset operator panel passwords via the Web client.
Web Client
1 Select Setup > User Management > Reset Operator Panel
Passwords.
2 Click Apply.
Local Authentication vs. Local authentication control is managed on the library. An administrator
Remote Authentication sets up accounts and privileges on the library. To use local
authentication, a user must enter a local user name and password.
Remote authentication is managed by a Lightweight Directory Access
Protocol (LDAP) server. Enabling LDAP allows existing user accounts
residing on an LDAP server to be integrated into the librarys current
user account management subsystem. User account information is
centralized and shared by different applications, simplifying user
account management tasks.
To use remote authentication, you must enable LDAP on the library.
Once LDAP is enabled, users can log into the library using either LDAP or
local authentication. To use LDAP authentication, a user must enter a
directory service user name and password. The Web client Login screen
displays the Remote Authentication login option only when LDAP is
enabled. See Logging in When LDAP or Kerberos is Enabled on
page 138.
LDAP logins are only available on the library Web client.
LDAP Server Guidelines The following groups must be created on the LDAP server to enable
remote login on the library:
Library User Group Assign users to this group who need user-
privilege access to the library. Enter the name of this group in the
Library User Group field on the Setup - Remote Authentication
screen on the library Web client (see Configuring LDAP on the
Library on page 90).
Partition Groups For LDAP users with user privileges, access to
library partitions is determined by group assignment on the LDAP
server. Groups must be created on the LDAP server with names that
match the library partitions names (names must match but are not
case sensitive). Users with user privileges must be assigned to these
groups on the LDAP server to have access to the corresponding
partitions on the library.
Library Admin Group Assign users to this group who need
administrator-privilege access to the library. LDAP users with
administrator privileges have access to all partitions and
administrator functions and do not need to be assigned to
partition-related groups on the LDAP server. Enter the name of this
group in the Library Admin Group field on the Setup - Remote
Authentication screen on the library Web client (see Configuring
LDAP on the Library on page 90).
You will need to have at least one user assigned to both the Library User
Group and the Library Admin Group on the LDAP server in order to test
the LDAP settings on the library (see Testing LDAP Settings on page 94).
Since most normal users will not be members of both these groups, you
may need to create a special or temporary user specifically for this
purpose.
Configuring Secure You can configure Secure LDAP using one of two methods (do not use
LDAP on the Library both).
LDAPS Uses Secure Sockets Layer (SSL) over a specific port for
LDAP (636). You may enable LDAP over SSL (LDAPS) by entering a
URI in the form of ldaps://hostname in the Server URI field. This
will use SSL to send secure communication via port 636. If the LDAP
server does not support LDAPS or does not have LDAPS enabled,
then login operations will fail. LDAPS has been deprecated in favor
of using StartTLS (see option below). Do not use LDAPS if you are
using StartTLS. Once you apply LDAPS, StartTLS will not be available.
StartTLS Uses Transport Layer Security (TLS) over the same port as
regular LDAP (389). Select the StartTLS check box to configure
secure LDAP communication using TLS. If TLS mode is not
supported on your LDAP server, then login operations will fail. Do
not use StartTLS if you are using LDAPS.
Additionally, if you are using one of these Secure LDAP methods listed
above, you can also Install a TLS CA certificate for additional verification
that the LDAP server has not been compromised. The certificate must be
the same certificate that is installed on your LDAP server and must be in
.pem format. The library will only perform the verification if you have
configured Secure LDAP (using either LDAPS or StartTLS). Place a copy of
the certificate file in an accessible location on your computer and use
the Browse button to locate and install it.
Once a certificate is installed, you can remove it by checking the
Remove TLS CA Certificate check box. This check box only becomes
available once a certificate is installed. The presence of this check box
lets you know that a certificate is installed. Refer to Figure 14 LDAP
Setup Example on page 93.
Configuring LDAP on Administrators can enable and configure Lightweight Directory Access
the Library Protocol (LDAP). LDAP is the industry standard Internet protocol that
provides centralized user account management.
Administrators can add, delete, and modify only local user account
information. The library Web client does not allow you to create,
modify, or delete user account information on an LDAP server. This must
be done by the directory service provider. For more information on
working with local user accounts, see Working With Local User Accounts
and Passwords on page 79.
The library supports all LDAP servers. You can also use Kerberos for
added security. For specific instructions on configuring Kerberos, see
Configuring Kerberos on page 94.
Web Client
1 Select Setup > User Management > Remote Authentication.
The Setup - Remote Authentication screen displays.
2 Under Authentication Type, do one of the following:
To enable LDAP, select LDAP and continue with Step 3.
To disable LDAP, select Local Only and continue with Step 4.
To modify LDAP configuration settings, continue with Step 3.
3 Obtain the following LDAP parameters from your network
administrator and enter them in the fields provided:
Server URI The Uniform Resource Identifier (URI) of the LDAP
server where user account information is stored. The URI
includes the LDAP server host name or IP address and can
include the LDAP server network port. Port 389 is the default.
Examples:
ldap://hostname:389
ldap://10.50.91.103
ldap://mycompany.com
LDAPS - Optional. See Configuring Secure LDAP on the Library
on page 90.
StartTLS - Optional. See Configuring Secure LDAP on the Library
on page 90.
Install TLS CA Certificate Optional. See Configuring Secure
LDAP on the Library on page 90.
Principal An LDAP user login ID with permissions to search
the LDAP directory. The library logs into LDAP using this ID.
For an example, see Figure 14 on page 93.
Password The password for the principal authorization login
ID.
Testing LDAP Settings The Test Settings button tests communication between the library and
the LDAP server, and tests the currently applied LDAP settings. If there
are any problems, an error message identifies the problem area.
If you change the LDAP settings, click Apply before using this button.
Otherwise, any changes you made will be lost and will not be tested.
To test the settings, you must enter a user name and password, then
click the button. The user you use for the test must be a member of both
the Library User Group and the Library Admin Group on the LDAP server.
Since most normal users will not be members of both these groups, you
may need to create a special or temporary user specifically for this
purpose.
After configuring LDAP settings, save the library configuration.
Configuring Kerberos Use Kerberos if you want extra security with remote authentication.
You can configure the Kerberos settings any time after the initial
library configuration. Before you can configure Kerberos, you need to
generate the service keytab file on your Kerberos (AD) server. For
instructions, see Generating the Kerberos Service Keytab File on
page 96.
You must have administrator privileges to configure Kerberos.
You can only configure Kerberos on the Web client.
Web Client
1 Make sure that both the library and the Kerberos/Active Directory
server are set to the same time (within 5 minutes). Otherwise, the
authentication will fail. It is recommended that you use Network
Time Protocol (NTP) to synchronize the time between the library and
the Kerberos server. See Setting the Date and Time Using the
Network Time Protocol on page 49.
2 Select Setup > User Management > Remote Authentication.
The Setup - Remote Authentication screen displays.
Generating the These instructions are for generating the service keytab file for use with
Kerberos Service Keytab Microsoft Active Directory. If you not using Active Directory, refer to
File your Kerberos vendor for instructions on generating this file.
1 Set up an Active Directory domain on the Windows 2003 server.
2 If Active Directory is not already configured, run dcpromo.
3 Windows 2003 servers only: Install Windows Support Tools on the
Windows 2003 server as follows:
a Go to www.microsoft.com and search for windows server
2003 support tools sp2 or click on the following link:
http://www.microsoft.com/downloads/
details.aspx?FamilyID=96a35011-fd83-419d-939b-
9a772ea2df90&DisplayLang=en
b Download both support.cab and suptools.msi.
c Run suptools.msi to begin installation.
4 Create a computer account in Active Directory.
Do not select any of the check boxes during creation.
The account name will be used for <computer account> fields
shown in the following steps.
5 At the command prompt, map SPN to the computer account. Use
the following format:
setspnAlibrary/<fqdnoflibrary><computer
account>
For example:
setspnAlibrary/delos.dvt.mycompany.comkerbtest
6 At the command prompt, create the keytab file for the SPN. Use one
of the following formats:
For Windows 2003:
ktpassoutlibrary.keytabprinc
library/<fqdnoflibrary>@<realm>
+rndPassptypeKRB5_NT_SRV_HSTcryptoRC4
HMACNTmapUser<realm>/computers/<computer
account>
For example:
ktpassoutlibrary.keytabprinclibrary/
delos.dvt.mycompany.com@OURREALM.LOCAL
+rndPassptypeKRB5_NT_SRV_HSTcryptoRC4
HMACNTmapUserourrealm.local/computers/
kerbtest
For Windows 2008:
ktpassoutlibrary.keytabprinclibrary/
<fqdnoflibrary>@<realm>
+rndPassptypeKRB5_NT_SRV_HSTcryptoAES256
SHA1
mapUser<realm>/computers/<computeraccount>
For example:
ktpassoutlibrary.keytabprinclibrary/
delos.dvt.mycompany.com@OURREALM.LOCAL
+rndPassptypeKRB5_NT_SRV_HSTcryptoAES256
SHA1
mapUserourrealm.local/computers/kerbtest
Operator Panel
1 Select Setup > Account Settings > Session Timeout.
The current timeout setting is highlighted.
2 Use the Up and Down buttons to select the desired timeout.
3 Press Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Unload Assist When Unload Assist is enabled, the library will unload tape drives when
a move command from the tape drive is received. When Unload Assist is
disabled, the tape drive must be unloaded prior to a move command, or
the move command will fail. This setting is enabled by default.
Operator Panel
1 Select Setup > System Settings > Unload Assist.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
Logical Serial Number The library uses the actual tape drive serial numbers by default (logical
Addressing SN addressing is disabled). Enabling logical SN addressing enables the
library to assign logical serial numbers to all tape drives in the library.
Specifically, the library assigns a logical serial number to a tape drive in a
specific location, not the serial number of the particular tape drive. If
the tape drive is then replaced by another tape drive in the same library
location, the logical serial number remains the same. From the host
applications perspective, the replacement tape drive is the same as the
original. This setting is disabled by default.
Operator Panel
1 Select Setup > System Settings > Logical SN Addr.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Power cycle the library.
6 Save the library configuration (see Saving the Library Configuration
on page 107).
Manual Cartridge Administrators can disable or enable (default setting) manual cartridge
Assignment assignment. When manual cartridge assignment is enabled, the I/E
Assign screen automatically displays on the operator panel once
cartridges are placed into the I/E station. The I/E Assign screen prompts
you to assign the cartridges to a specific partition. The cartridges can
then be used only by the assigned partition.
When manual cartridge assignment is disabled, the I/E Assign screen
does not display on the operator panel, and the cartridges in the I/E
station are visible to all partitions, as well as the System partition, and
can be used by any partition.
The manual cartridge setting is enabled by default. You can only change
this setting on the operator panel.
Operator Panel
1 Select Setup > System Settings > Man Cart Assign.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
SNMP Enables or disables SNMP traffic to the library. This setting is enabled by
default.
Operator Panel
1 Select Setup > System Settings >SNMP.
2 Select the setting you want to modify and press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 When finished making all changes, press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
SMI-S Allows you to enable or disable SMI-S running on the library. This
setting is disabled by default.
Operator Panel
1 Select Setup > System Settings > SMI-S.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Power Save To help save power, the operator panel goes dark after a period of
inactivity on the operator panel (meaning, no buttons have been
pressed). The default period is 30 minutes. You can set this period to 15
minutes, 30 minutes, 45 minutes, 60 minutes, or never.
To immediately restore the operator panel screen once it has gone dark,
press any of the four navigation buttons on the library.
The operator panel will restore when any of the following happens:
Any navigation button is pressed.
The Assign I/E screen displays (see Manual Cartridge Assignment on
page 100).
Tape drives start to autolevel.
The library receives a signal to shut down.
Library health (diagnostic ticket) status changes.
Library ready status changes.
The operator panel will NOT go dark when:
The library is initializing.
Tape drives are autoleveling.
The Assign I/E screen is displayed (see Manual Cartridge Assignment
on page 100).
An operator panel-initiated operation is in progress (such as IVT).
The Setup Wizard is displayed.
Passwords are enabled on the operator panel and a user is logged
in.
The power save timeout value is set to NEVER.
Operator Panel
1 Select Setup > System Settings > Power Save.
2 Press Modify.
3 Use the Up and Down buttons to select the desired setting and
press Apply.
Network Interface Enables or disables all external access to the library. This setting is
enabled by default to allow external access.
Operator Panel
1 Select Setup > Security Services > Network IF.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
SSH Services Enables or disables Secure Shell (SSH) services, such as SSH, from
accessing the library. This setting is enabled by default.
Operator Panel
1 Select Setup > Security Services > SSH Services.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Internet Control Enables or disables external attempts to discover the library by pinging
Message Protocol it (by means of the ICMP Echo packets. This setting is enabled by
(ICMP) default.
You may disable this feature if you are using IPv4, but you should NOT
do so if you are using IPv6. Disabling this feature disables all IPv6
communication on the Scalar i40 and Scalar i80. There will be no error
messages, and the library will appear to be working, but it will not be
communicating.
Operator Panel
1 Select Setup > Security Services > ICMP.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Remote Access Via Web Enables or disables remote access to the library via the Web client. This
Client setting is enabled by default (meaning remote access is allowed).
Operator Panel
1 Select Setup > Security Services > Web client.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Remote Service Login Enables or disables remote service user login (from the Web client or
over the Ethernet service port). The service user will still be able to log in
to the library from the operator panel. This setting is enabled by default
(meaning remote service login is allowed).
Operator Panel
1 Select Setup > Security Services > Service User
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
SNMP V1/V2 This topic is discussed in Enabling SNMP Versions on page 46.
SSL Allows you to enable Secure Socket Layer (SSL) for secure data
transmission between the library and remote clients. This setting is
disabled by default.
Enabling SSL encrypts all Web browser connections to the Web client,
and it enables SSL-based authentication for SMI-S. SMI-S is the newest
standard of SNMP, which makes sets of data continuously available. For
more information about SMI-S on the library, see SMI-S on page 101.
Disabling SSL creates an unencrypted connection from a Web browser
to the Web client.
See the Quantum Intelligent Libraries SMI-S Reference Guide
(6-01317-xx) for further configuration and access details.
Note: Before enabling SSL, make sure you enter a name for the library
in the Host Name text box when configuring network settings
(Setup > Network Management > Network on the Web
client; see Library Host Name on page 41). After enabling SSL,
use that host name to access the library. If you do not use that
name, you will receive a security alert. In addition, make sure to
complete all the text boxes listed on the Web client Contact
Information screen (Setup > Notification > Contact
Information) before enabling SSL. This information is used to
identify company information in the SSL certificate.
Operator Panel
1 Select Setup > Security Services > SSL.
2 Press Modify.
3 Use the Up and Down buttons to select Enabled or Disabled and
press Apply.
4 Make another selection or press Exit.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Saving the Library This operation saves your current library configuration and library
Configuration firmware.
It is recommended that you save the library configuration after
modifying a configurable item and before upgrading firmware. This
allows you to restore the most current settings if necessary.
Save your library configuration when it is in a known working state. In
the event of a hardware failure, the saved configuration can be used to
restore the configuration after hardware repairs are made.
Before initiating a firmware upgrade, you should save the library
configuration. You then have the option to restore the configuration
after either a successful or an unsuccessful upgrade.
You can only save the configuration from the Web client.
Web Client
1 Select Tools > Save/Restore Configuration.
2 Select Save System Configuration.
3 Click Apply.
4 When the operation completes successfully, complete the next
screens to save the file to a known location.
Restoring the Library You can restore the librarys configurable items to a previous state using
Configuration a saved configuration file. If you updated the library firmware since last
saving the configuration, the library automatically restores the library
firmware to the version that was saved with the configuration.
You can only restore the library configuration via the Web client.
Web Client
1 Select Tools > Save/Restore Configuration.
2 Select Restore System Configuration.
3 Click Apply.
4 Use the next screens to browse to the saved configuration file and
upload it to the library.
This operation saves your current library configuration and library
firmware.
5 Verify the drive firmware level, and if necessary, manually upgrade
to the desired firmware level.
Web Client
Select Setup > Register Library.
Changing to Alternate 1 Select Setup > System Settings and press Select.
Home Screen 2 Select Alternate Home and press Modify.
3 Select Up to choose Unlock I/E, and press Apply.
4 Select Exit twice to return to the alternate home screen.
Note: From the alternate home screen, selecting Menu returns you to
the default home screen. To return to the alternate home
screen, select Actions > Alternate Home, and press Select.
Unlocking the I/E is described in Unlocking and Opening the I/E Station
on page 145.
Returning to Default 1 From the alternate home screen, select Menu to return to the
Home Screen default home screen.
The default home screen is displayed temporarily, however upon
power cycle will display the alternate home screen until reset
permanently.
2 To reset to view the default home screen permanently, select
Setup > System Settings and press Select.
3 Select Alternate Home and press Modify.
4 Select Down and press Apply.
Select Exit twice to return to the default home screen.
Note: You can work with Advanced Reporting Data using only the
Web client.
Required Firmware To use all the features of Advanced Reporting, you should install the
latest released version of library firmware on your library. For
information on installing library firmware, see Updating Library
Firmware on page 299.
Prerequisites To configure control path failover, you must have the following setup on
your library:
Advanced Reporting License. Refer to Adding or Upgrading
Licensable Features on page 69.
The control path and failover tape drives must both be HP LTO-5 FC
tape drives, and you must have a minimum of two drives in a single
partition.
The control path and failover tape drives must have their topology
configured as Point to Point. Refer to Configuring Tape Drive
Parameters on page 65.
The control path and failover tape drives must be connected to an
NPIV-enabled switch on the same fabric. They must not be
connected to an FC I/O blade.
Configuring CPF You can configure control path failover from the Web client only.
Web Client
1 Setup the drive topology.
Set the topology for the control path and control path failover tape
drives to Point to Point. For more information, refer to Configuring
Tape Drive Parameters on page 65.
a Select Setup > Drive Settings.
The Setup - Drive Settings screen displays.
Column Indicates
Column Indicates
3 Select the partition on which you want to force the failover, and
click Apply.
4 Click Apply.
The new active tape drive location displays in the Active Drive
column. The new standby tape drive location displays in the
Standby Drive column.
Note: If the new tape drive locations do not display, refresh the
browser.
Configuring the Drive This report identifies how tape drive resources are utilized in your
Resource Utilization library. You can use this report to help you determine the proper work
Report load distribution between the tape drives in your library.
The following information is collected for each tape drive installed in the
library:
Drive location (module, row)
Drive serial number
Partition
Megabytes read
Megabytes written
Time and date of mount (UTC)
Time and date of dismount (UTC)
Media motion time (in seconds)
Tape cartridge barcode
You can only access this report from the Web client.
Web Client
1 From the library menu bar, select Reports > Advanced Reporting >
Drive Resource Utilization.
3 Click Next.
The report is generated and displays on the screen.
Configuring the Media This report provides TapeAlert counts for various combinations of tape
Integrity Analysis drives, tape cartridges, and TapeAlert flags. You can use this report to
Report help determine if a problem is due to a specific tape drive or tape
cartridge.
The Media Integrity Analysis report collects the following information
for each TapeAlert:
Date/Time
Tape drive physical serial number
Cartridge barcode
TapeAlert value
TapeAlert Description
You can only access this report from the Web client.
Web Client
1 From the library menu bar, select Reports > Advanced Reporting >
Media Integrity Analysis.
Using Advanced If you want to use the same configuration repeatedly, you can save it as
Reporting Templates a template. You can save up to 20 templates for each type of advanced
report.
You can only work with templates from the Web client.
Web Client
6 Reloads the data from the library log file to the Internet browser.
7 Lists the number of records currently loaded in the Internet browser for this report.
4 Click Save.
The report appears in the drop-down list next to the Load button.
Deleting a Template
To delete a template, select the template from the drop-down list and
click Delete.
Loading and Reloading When you first open an Advanced Report configuration screen, the
Advanced Reporting system loads all the data from the library log file for that report to the
Data Internet browser in preparation for creating your reports. If there is a lot
of information in the log files, this may take several minutes.
The data that is loaded in the Internet browser remains unchanged until
you log out of your library session or reload the data. If new data is
added to the library log file during your session (for example, a
TapeAlert occurs), it will not appear in the on-screen report until you
either log out of the library and log on again, or reload the data.
To reload the data without logging out, click the Reload button on the
reports configuration page. This action reloads the entire data for that
report, which may again take several minutes.
You can see how many records were loaded from the log files for this
report by looking at the Report Data section of the Report Configuration
page. A note says XX records read, where XX is the number of records
(see Figure 20 on page 125).
Deleting Advanced In some circumstances, you may wish to delete the information
Reporting Data contained in the log files used to build the advanced reports. To do this,
click the Delete button in the Report Data section of either report
configuration pagesee Figure 20 on page 125. This action deletes the
data for both the Drive Resource Utilization report and the Media
Integrity Analysis report.
Caution: Once you delete the data in the log files, you cannot get it
back. The Reload button does NOT retrieve deleted data! It
is recommended that you save all the data for both the
Drive Resource Utilization report and the Media Integrity
Analysis report before deleting the data (see Saving and E-
mailing Advanced Reporting Data Files on page 125).
Saving and E-mailing You cannot save the report as it appears on the screen, but you can save
Advanced Reporting or e-mail the report data as a comma-separated values (.csv) file. You
Data Files can then import the .csv data into a spreadsheet program and
manipulate it to create your own reports for analysis. The .csv file
contains all of the data in the log file that falls within the date range
you specify.
You can only access this report from the Web client.
Web Client
1 Generate a report.
2 Scroll down to the bottom of the report viewing screen to a box
titled Retrieve the Report Data File. See Figure 21 on page 126.
3 To save the report data as a.csv file, click Save.
4 To e-mail the report data as a .csv file, type the name of a recipient
in the empty field next to the E-mail button, then click E-mail.
Configuring Media You can choose to collect data in a log to list the following conditions
Security that occur in your library:
Unexpected removal of media after a power-up and reboot
Unexpected removal of media during library operation
Expected removal of media from I/E Slots during library operation
Once configured, the library issues diagnostic tickets for the selected
conditions, and collects the media removal conditions in the logs. To
configure the Media Security, do the following:
You can only access this report from the Web client.
Web Client
1 Select Setup > Notifications > Advanced Reporting > Media Security.
The Setup - Advanced Reporting Media Security screen displays.
2 Click to enable any or all of the options.
Unexpected Removal Detection After Power-Up and Reboot
Only
Unexpected Removal Detection During Library Operation
Expected Removal Detection From I/E Slots During Library
Operation
3 Click Apply.
The Progress Window displays. The Progress Window contains
information on the action, elapsed time, and status of the
requested operation.
If Success appears in the Progress Window, the operation
completed successfully. Click Close to close the Progress
Window.
If Failure appears in the Progress Window, the operation did
not successfully complete.
4 To view the Media Security Log, select Reports > Log Viewer and
then select Media Security Log.
Viewing, Saving, and E- Using the Web client, you can view, save, or e-mail the Media Security
mailing Media Security Log.
Log You can only access this report from the Web client.
Web Client
1 Select Reports > Log Viewer.
2 Select Media Security Log from the list of logs and click Next.
The report displays in a new window for viewing.
3 You can save or e-mail the report following the on-screen
instructions.
Note: If you want to e-mail the log file to a recipient, type the
recipients name in the text box next to the E-mail button,
and then click the E-mail button. You must have your e-
mail notification configured in order to e-mail a log file.
See Configuring the Library E-Mail Account on page 76 for
more information.
Web Client
1 To view, save, or e-mail the report, select Reports > Log Viewer.
2 Select Media Usage Log from the list of logs and click Next.
Note: Before the library can send e-mail notifications, you must
configure the library e-mail account. For information on how to
configure the e-mail account, see Configuring the Library E-
Mail Account on page 76.
You can create up to 20 e-mail recipients. If you want to send the same
recipient a different set of reports, you can enter the same e-mail
address more than once, with different reports selected for each. Each
entry counts as a unique recipient toward the 20 total.
Note: Duplicate entries are not allowed. A duplicate entry means the
same recipient is set to receive the exact same reports in two
different entries, regardless of the day or time. If you have
duplicate recipients, make sure that the reports selected in
each entry are not an exact match.
Each e-mail notification includes an optional comment text box you can
use to enter information about the library or the reports and logs that
you want the recipient to know. This information appears in the body of
the e-mail.
You can modify the settings of an existing e-mail notification at any time
after it is created. If an e-mail notification is no longer needed, you can
delete it.
Administrators can configure the library e-mail account and e-mail
notifications. Users with user privileges can receive e-mail notifications,
but they cannot configure the library e-mail account or e-mail
notifications.
2 Click Create.
The Setup - Advanced Reporting Receiver Address Configuration
screen displays. The screen lists all Advanced Reporting e-mail
notifications that have been created, along with the day/time the e-
mail is scheduled to be sent, and which reports and logs will be
sent.
3 Under Select Reports, select the check box of the report(s) and
log(s) you want to send.
4 Under Notification Day & Time, there are two drop-down lists.
From the first drop-down list, select the day of the week you want
to send the e-mail, or select Daily to send every day. From the
second drop-down list, select the time of day to send the e-mail
(hourly, using a 24-hour clock).
5 In the E-mail Address field, enter the recipient's e-mail address.
6 In the E-mail Comment field, enter a comment that will be sent in
the body of the e-mail (optional).
7 Click Apply.
8 On the Success window, click Close.
This chapter explains how to access and operate your library. Most of
the library functions described here can be found on the Operations
menu of the Web client, or the Actions menu of the operator panel.
This chapter covers:
Logging In
Logging Out
Shutting Down, Restarting, Turning Off, and Removing Power
Emergency Power-off Procedure
Unlocking and Opening the I/E Station
Releasing Magazines
Performing Media Operations
Cleaning Tape Drives
Taking a Tape Drive Online or Offline
Logging In
All users, service users, and administrators must log in to the library to
perform library functions or view library operations. (Exception: If
passwords are not configured on the operator panel, login to the
operator panel is not required.)
Simultaneous Logins Multiple users can be logged in to the library at the same time. The
same user can be logged from multiple locations. Note that multiple
users logged in from different locations cannot make changes to
configuration settings or perform certain library functions
simultaneously. The screens are visible, but access is denied. Whichever
one is logged in first has access to the screen until they exit the screens.
Logging in for the First When you first boot up the library, the operator panel does not require
Time you to log in. (In fact, if you do not configure passwords for the
operator panel, you never need to log in to the operator panel; see
Enabling and Creating Passwords on the Operator Panel on page 84 for
more information.)
To log in to the Web client for the first time:
1 Make note of your librarys IP address. From the operator panel,
select Reports > Network Settings to display the IP address.
2 Enter the IP address in your Internet browser to bring up the Web
client login screen.
3 Enter the default user name and password:
Default user name: admin
Default password: password
4 Click OK.
After you log in for the first time, change the password for the default
admin account. See Modifying Local User Accounts on the Web Client
on page 83.
Note: If you misplace the password for the default admin account,
contact Quantum Support. For contact information, see
Getting More Information or Help on page xxvii.
Logging in Using the If passwords have not been set on the operator panel, you do not need
Operator Panel to log in, and all operations are allowed to all users. It is recommended
that you set passwords on the operator panel (see Enabling and
Creating Passwords on the Operator Panel on page 84).
If passwords have been set on the operator panel, there are three
possible user IDs: admin, user, and service. Log in as follows:
1 At the login screen, use the Up and Down buttons to select admin,
user, or service.
2 Press Apply.
3 Enter the first digit of the password using the Up and Down
buttons to scroll to the correct number, then press Right to go to
the next digit. Enter the rest of the digits in the same way.
Note: If you misplace the password for the operator panel logins, you
can clear operator panel passwords via the Web client (see
Resetting Passwords on the Operator Panel on page 88).
Logging in Via the Web 1 Establish an Internet connection to the library by typing the librarys
Client IP address into your Internet browser.
If you do not know your librarys IP address, you can find it on the
operator panel by selecting Reports > Network Settings.
2 At the login screen, enter a user name and its associated password
and click OK.
Logging in When LDAP When LDAP or Kerberos is enabled, the Web client Login screen displays
or Kerberos is Enabled a Remote Authentication check box. Log in as follows:
Select the Remote Authentication check box to log in using a
directory service user name and password.
Clear the Remote Authentication check box to log in using a local
user name and password.
For more information on LDAP, see Configuring LDAP on the Library on
page 90.
For more information on Kerberos, see Configuring Kerberos on
page 94.
Logging Out
Logging out secures the library from being accessed by unauthorized
users. Log out whenever you have finished accessing the library.
Note: You will only be able to log out of the operator panel if
passwords have been configured (see Enabling and Creating
Passwords on the Operator Panel on page 84).
Note: Clicking the close button (X) in the upper-right corner of the
Web client closes the browser window but does not log you
out.
Operator Panel
1 Select Actions > Logout.
2 Press Yes to confirm.
Web Client
1 Click the Logout button in the upper right corner of the screen,
or select Operations > Log Out.
2 Click OK to confirm.
The steps for shutting down, turning off, and completely removing
library power are:
1 Make sure the connected host applications are not sending
commands to the library and that all library operations have
stopped.
2 Shut down the library using the operator panel or Web client (see
Shutting Down the Library on page 140).
3 Turn OFF the library by pressing the power button on the front
panel (see Turning Off the Library on page 143).
Shutting Down the Shutdown shuts down the librarys operating system and firmware,
Library closes data and log files, and retracts the picker so that a tape cartridge
or the picker fingers are not stuck part way into a tape drive or
magazine slot. If the robot was in the middle of a get or put operation,
it will attempt to complete the operation before shutting down, by
either pushing the cartridge into the destination slot, or removing it
completely from the slot and stopping in a safe location from which it
can move again once power is restored.
Once the shutdown is complete, you can safely turn off the library by
pressing the power button on the front panel (see Turning Off the
Library on page 143).
Operator Panel
1 Make sure the connected host applications are not sending
commands to the library and that all library operations have
stopped.
2 Press Actions > Shutdown > Shutdown Library.
3 Press Yes to confirm.
A shutdown in progress message displays on the operator panel
(see Figure 22).
Figure 22 Shutdown in
Progress Message
5 Turn OFF the library by pressing the power button on the front
panel.
Web Client
1 Press Operations > System Shutdown.
2 Select Shutdown and click Apply.
3 Click OK to confirm.
4 Wait until the ready to power down message displays on the
operator panel (see Figure 24).
5 Turn OFF the library by pressing the power button on the front
panel.
Restarting the Library Restart shuts down and then reboots the library's operating system and
firmware. During the reboot, the library performs an inventory of the
tape drives and magazine slots. If any tape drives or partitions were
previously taken offline, restarting the library brings them back online.
The reboot takes approximately 5 minutes.
Operator Panel
1 Make sure the connected host applications are not sending
commands to the library and that all library operations have
stopped.
2 Press Actions > Shutdown > Restart Library.
3 Press Yes to confirm.
4 Several messages appear on the screen, in the order shown in
Figure 25. Do not do anything in response to these messages. The
library will restart and initialize on its own.
Web Client
1 Make sure the connected host applications are not sending
commands to the library and that all library operations have
stopped.
2 Press Operations > System Shutdown.
3 Select Restart and click Apply.
4 Press OK to confirm.
5 Several messages appear on the operator, in the order shown in
Figure 25 on page 142. Do not do anything in response to these
messages. The library will restart and initialize on its own.
Turning Off the Library Turning OFF the library means pressing the power button on the front
panel.
It is recommended that you perform a shutdown via the Web client or
operator panel before turning off the library. If you do not perform a
shutdown, the library attempts to complete all shutdown operations
before turning off the library. However, it may not have enough time to
shut down completely, and operations could be stopped mid-process.
Note: Turning off the library does not completely remove library
power (see Completely Removing Library Power on page 144).
Completely Removing Completely removing library power means disconnecting the power
Library Power cord from each power supply on the library.
Caution: You should always perform a shutdown and then turn off
library power before completely removing power.
Otherwise, the following could occur:
The library may not complete closing all data and log
files.
If you turn off power or unplug the power cord while
writing to tape, the data on the tape could become
corrupted.
The robot may become frozen in the middle of an
operation and unable to move once library power is
restored, possibly requiring a service call.
Emergency Power-off In an emergency, you may need to turn off power immediately to stop
Procedure robot motion, bypassing the normal shutdown process.
In an emergency, you can turn off power in one of two ways:
Press the power button on the front of the library to turn the library
OFF. It may take up to 4 seconds for all motion to completely stop.
Note that this does not completely remove library power (you need
to disconnect the power cords to do that).
Disconnect the power cord from each power supply on the back of
the library. It may take 1 to 2 seconds for motion to completely
stop.
Taking the Library Some maintenance activities require that the entire library be taken
Offline offline. To take the library offline, change the mode of all partitions from
online to offline. See Taking a Partition Online or Offline on page 59 for
instructions.
Note: Because the I/E station is part of the magazine, all storage slots
contained in that magazine are unavailable to applications
during the time that the I/E station is open.
Note: On the Scalar i80, if you want to open more than one I/E
station, such as when importing multiple tape cartridges,
unlock and open both I/E stations before you close either of
them. Otherwise, if you open and close one at a time, you must
wait for the robot to complete inventory on the one being
closed before it can open the other one.
For more information about the physical location and capacity of the I/E
station, see Configuring I/E Station Slots on page 63.
Operator Panel
1 If viewing from the default home screen, select Actions >
I/E > Unlock I/E Station. If viewing from the alternate home
screen, select Unlock.
2 If more than one I/E station is configured on the library, select which
I/E station to unlock, and press Unlock for the desired selection.
3 Wait until the robot unlocks the I/E station and the screen displays
the I/E Station is Unlocked message (see Figure 26).
Web Client
1 Select Operations > I/E Station Unlock.
2 Select an I/E station to unlock and click Apply.
Releasing Magazines
Magazines are locked during normal operation. Before you open or
completely remove a magazine, you must release it, either via the user
interface or manually, as described in:
Releasing Magazines via the User Interface on page 149
Releasing Magazines Manually on page 150
When you give the command to release a magazine via the operator
panel or Web client, the robot physically moves to the unlock
mechanism and unlocks it. This takes a few seconds. Once unlocked,
you have 30 seconds to open the magazine before it locks again.
Note: If you want to remove more than one magazine, such as when
bulk loading tape cartridges, release and remove all the
magazines you want to remove before you close any of them.
Otherwise, if you remove and replace them one at a time, you
must wait for the robot to complete inventory on the one
being replaced before it can release another one.
Caution: If the library is turned ON, always release the magazines via
the user interface. It is easier and will not result in a
diagnostic ticket (see About Diagnostic Tickets on
page 312). Additionally, the library makes sure nothing is
physically blocking the magazine that could cause damage
to library components before allowing you to release it.
Releasing Magazines Use this method when the library is turned ON.
via the User Interface
Operator Panel
1 Select Actions > Magazine.
2 Select a magazine and press Release.
3 Wait until the robot unlocks the magazine and the screen displays
the Magazine is now unlocked message (see Figure 28).
Web Client
1 Select Operations > Release Magazine.
2 Select a magazine and press Apply.
3 Click OK to confirm.
The Progress Window displays. The Progress Window contains
information on the action, elapsed time, and status of the
requested operation. Do one of the following:
If Success appears in the Progress Window, the magazine was
unlocked. Click Close to close the Progress Window. The
operator panel displays the status Unlocking and then Idle.
If Failure appears in the Progress Window, the magazine did
not unlock.
4 Within 30 seconds, pull outward on the magazine bezel handle to
slide the magazine out as far as you wish, or remove it completely.
Once you slide the magazine back into the slot all the way, it locks
again automatically.
If you do not open the magazine within 30 seconds, it locks.
Releasing Magazines Use this method when the library is turned OFF. If you use this method
Manually when the library is turned ON, you will receive a diagnostic ticket.
On the Scalar i40 and the bottom right magazine of the Scalar
i80, reach under the open magazine and insert the tool directly
into the access hole in the library chassis to depress the release
latch, while pulling outward on the magazine bezel handle.
On the top right magazine of the Scalar i80, reach under the
open magazine and press the release latch directly with your
finger, while pulling outward on the magazine bezel handle.
Importing Tape You can use the I/E station to import data cartridges into the library. The
Cartridges librarys scanner automatically reads the barcode on new cartridges
imported into the library.
Tape cartridges must be present in the I/E station and assigned to a
partition before you can import them. You will select a partition into
which to import the cartridges. If the selected partition is online, it will
be taken offline before the import operation is performed, and brought
back online after the operation is complete. If the library contains
multiple partitions, the import operation will not affect operations in
other partitions.
You must have access to the librarys I/E station and the operator panel
to import cartridges.
Note: All tape cartridges must have a unique, external barcode label
that is machine readable. See Supported Barcode Formats on
page 338 and Installing Barcode Labels on page 339 for more
information.
Note: If your library has zero I/E station slots, you cannot import or
export media using the I/E station. See Configuring I/E Station
Slots on page 63.
Note: You can select all cartridges by selecting the top check box.
You can use the Filter by Barcode text box to filter the
available cartridge barcodes. Click the Help button next to
the Find button for more information about filtering
barcodes. In addition, if not all cartridges appear on the
screen, use the Page 1 of x arrows to view the additional
cartridges.
6 Click Apply.
7 Click OK to confirm it is OK to take the partition offline.
The library imports the tape cartridge(s) into the first empty slot(s)
in the partition.
Bulk Loading Tape Bulk loading is another way to load media into the library. If zero I/E
Cartridges station slots are configured, you will always need to bulk load cartridges
into the library. If I/E station slots have been configured, you may want
to perform an initial bulk load when you first start using your library.
The library will perform an inventory after the bulk load is complete.
Before bulk loading, print out the Library Configuration report from the
Web client to see how the physical slots of the library are configured.
The report shows what slots are unavailable or configured as cleaning
slots or as I/E station slots. For information on accessing the report, see
Viewing the Library Configuration Report on page 210.
Place cartridges in their appropriately configured slot location; for
example, cleaning cartridges should not be placed in slots configured
for storage.
To perform an initial bulk load, remove the magazine and manually
insert tape cartridges directly into storage slots (see Releasing
Magazines on page 148). When finished loading the cartridges, reinstall
the magazine and push it in until it is completely closed.
After the initial bulk load, you can use the Import Media screen to add
cartridges without interrupting library operations, as long as I/E station
slots have been configured. For more information, see Importing Tape
Cartridges on page 152.
Moving Tape Cartridges Once a cartridge has been imported into a library and assigned to a
partition, it can be moved to a tape drive for data access, to a storage
slot for storage, or back to the I/E station for removal from the library.
Details on using the library to move media include:
If your library has zero I/E station slots, you cannot move cartridges
to and from the I/E station. See Configuring I/E Station Slots on
page 63.
You can move a cartridge from one location to another within a
partition. You can also move unassigned cartridges from the I/E
station to available locations in the library. If you move an
unassigned tape cartridge into a slot in a partition, it will become
assigned to that partition and will only be available for use by that
partition.
Web Client
1 Select Operations > Media > Move.
2 If more than one partition exists, select the partition that contains
the cartridge you want to move and click Next.
The Move Media - Partition (Mode) screen displays, where
Partition is the name of the partition and Mode is the current mode
of the partition.
3 In the Select Media section, select the source cartridge you want to
move.
Note: You can use the Filter by Barcode text box to filter the
available cartridge barcodes. Click the Help button next to
the Find button for more information about filtering
barcodes. In addition, if not all cartridges appear on the
screen, use the Page 1 of x arrows to view the additional
cartridges.
Exporting Tape The Export Media operation enables you to export data cartridges from
Cartridges storage slots to empty I/E station slots for removal from the library.
Details on exporting cartridges include:
Exporting cartridges using the library Web client may necessitate
performing an inventory on your host application. If the host
application has issued a prevent media removal command to the
library, you will not be able to use the library Web client to export
cartridges. In addition, you can export cartridges using your host
application. For more information, see your host application
documentation.
If the partition is online, it will be taken offline before the export is
performed, and brought back online after the export is complete.
You will be asked to confirm that you want to take the partition
offline.
If your library has zero I/E station slots, you cannot export
cartridges. See Configuring I/E Station Slots on page 63.
If you have AutoClean enabled, you can also export cleaning
cartridges. For information, see Exporting Cleaning Cartridges on
page 167.
You can select only the partitions to which you have been given
access.
You can only export cartridges if empty I/E station slots are available.
You must have access to the librarys I/E station and the operator
panel to export cleaning cartridges.
You can export cartridges using either the operator panel or the Web
client.
Operator Panel
1 Select Actions > I/E > Export Tape.
2 If more than one partition exists, use the Up and Down buttons
select the partition that contains the source cartridge you want to
export, then press Select.
3 A list of all the tape cartridges in storage slots in the selected
partition displays. Use the Up and Down buttons to select a tape
cartridge for export. You may also select ALL to export all cartridges;
however, the ALL option is only available if there are enough empty
slots in the I/E station to accommodate all the cartridges in the
selected partition.
4 Press Export.
5 When the screen displays confirmation that the export completed,
press OK.
6 Once the operation completes, you may open the I/E station and
remove the cartridges (see Unlocking and Opening the I/E Station
on page 145).
Web Client
1 Select Operations > Media > Export.
2 If more than one partition exists, select the partition that contains
the source cartridge you want to export.
3 Click Next.
The Export Media - Partition (Mode) screen displays, where
Partition is the name of the partition and Mode is the current mode
(online or offline) of the partition.
4 Note the number of empty I/E station slots that appear in the
Empty I/E Station Slots field. The number of cartridges you can
export is limited to the number of empty I/E station slots. You
cannot export cartridges if all I/E station slots are full.
Note: You can use the Filter by Barcode text box to filter the
available cartridge barcodes. Click the Help button next to
the Find button for more information about filtering
barcodes. In addition, if not all cartridges appear on the
screen, use the Page 1 of x arrows to view the additional
cartridges.
6 Click Apply.
7 Click OK to confirm it is OK to take the partition offline.
The robot moves the cartridge to the I/E station. A success
message displays when the export completes.
8 Once the operation completes, you may open the I/E station and
remove the cartridges (see Unlocking and Opening the I/E Station
on page 145).
Loading Tape Drives The Load Drive operation enables you to load a cartridge from a storage
slot into a tape drive. The storage slot and tape drive must be assigned
to the same partition.
This topic focuses on using the library user interface, not the host
application, to load tape drives. Using the library to load tape drives
may necessitate performing an inventory with the host application. See
your host application documentation for more information.
Details on loading tape drives include:
The storage slot and tape drive must be assigned to the same
partition.
The tape cartridge must be compatible with the tape drive.
If the partition is online, it will be taken offline before the load
operation is performed and brought back online after the operation
is complete. You will be asked to confirm that you want to take the
partition offline.
You can select only partitions to which you have been given access.
Default tape drive locations are highlighted if the barcode field is
empty or the field is cleared.
You can only load tape drives from the Web client.
Web Client
1 Select Operations > Drive > Load.
2 If more than one partition exists, select the partition that contains
the tape drive you want to unload, and click Next.
3 The Load Drive - Partition (Mode) screen displays, where Partition
is the name of the partition and Mode is the current mode of the
partition (online or offline).
4 In the Select Media section, select the cartridge you want to load
into a tape drive.
Note: You can use the Filter by Barcode text box to filter the
available cartridge barcodes. Click the Help button next to
the Find button for more information about filtering
barcodes. In addition, if not all cartridges appear on the
screen, use the Page 1 of x arrows to view the additional
cartridges.
Unloading Tape Drives The Unload Drive operation allows you to unload a cartridge from a
tape drive to a storage slot. The storage slot and tape drive must be
assigned to the same partition.
This topic focuses on using the library user interface, not the host
application, to unload tape drives. Using the library to unload tape
drives may necessitate performing an inventory with the host
application. See your host application documentation for more
information.
Details about unloading tape drives include:
The tape drive and storage slot must be assigned to the same
partition.
Only drives with media loaded appear on the screen.
You can select only partitions to which you have been given access.
If the affected partition is online, it will be taken offline before the
unload operation is performed, and brought back online after it is
complete.
You can unload media from the operator panel or the Web client.
Operator Panel
1 Select Actions > Tape Drive > Unload.
2 If more than one tape drive is installed in the library, use the Up and
Down buttons to select a tape drive to unload.
3 Press Unload.
Web Client
1 Select Operations > Drive > Unload.
2 If more than one partition exists, select the partition that contains
the tape drive you want to unload.
3 Click Next.
The Unload Drive - Partition (Mode) screen displays, where
Partition is the name of the partition and Mode is the current
mode of the partition. The screen contains a list of all tape drives in
the partition that are loaded with a cartridge.
4 Select the tape drive you want to unload.
Note: If not all drives appear on the screen, use the Page 1 of x
arrows to view the additional cartridges.
5 Click Apply.
6 Click OK to confirm it is OK to take the partition offline.
The library attempts to unload the tape cartridge and move it into
the storage slot it was in when it was originally loaded into the tape
drive. If that storage slot is full, the library will attempt to move it
into another empty slot in the partition. If no empty slots exist, the
unload operation will fail. If this happens, you can try to perform a
move operation to move the cartridge from the tape drive to an I/E
station instead (see Moving Tape Cartridges on page 156), or free
up a storage slot and try the unload operation again.
Valid Cleaning Use universal cleaning cartridges to clean tape drives. If you attempt to
Cartridges clean a tape drive using a non-cleaning cartridge, the library may show
that the operation completed, but the tape drive will not be cleaned,
and the library will issue a diagnostic ticket.
Universal cleaning cartridges are designated by labels that begin with
CLN or CLNU or end with C1, C2, C3, C4, or CU. Examples: CLN123,
CLNU123L1, CLN123C1, 123CU, 123C1.
Cleaning cartridges, like all other cartridges imported into the library,
must have a unique, external barcode label that is machine readable.
See Supported Barcode Formats on page 338 and Installing Barcode
Labels on page 339 for more information.
About AutoClean Configuring one or more dedicated cleaning slots automatically enables
AutoClean see Configuring Cleaning Slots on page 61). Cleaning
cartridges are stored in designated cleaning slots. When a tape drive
needs cleaning, it notifies the library, and the library automatically
cleans the tape drive using a cleaning cartridge loaded in a cleaning
slot. Automatic cleaning is integrated into routine library operations. For
example, if the host application requests the library to move a tape
cartridge, and the tape drive performing the operation needs cleaning,
the library will perform the move operation and then automatically
clean the tape drive with a cleaning cartridge before informing the host
application that the move operation is complete.
Enabling AutoClean To enable AutoClean, all you need to do is configure at least one
cleaning slot in the library. For information on configuring cleaning
slots, see Configuring Cleaning Slots on page 61.
Importing Cleaning When AutoClean is enabled (at least one cleaning slot has been
Cartridges configured), you can import cleaning cartridges from the I/E station to
designated cleaning slots. For information on configuring cleaning slots,
see Configuring Cleaning Slots on page 61.
When manual cartridge assignment is enabled (the default setting), you
cannot import cartridges until you have assigned them to a specific
partition or to the System partition. Cleaning cartridges should always
be assigned to the System partition. Assigning cleaning cartridges to the
System partition makes them available to all partitions in the library. For
more information about manual cartridge assignment, see Manual
Cartridge Assignment on page 100.
You must have access to the librarys I/E station and the operator panel
to import cleaning cartridges.
Note: If your library has zero I/E station slots, you cannot import or
export cleaning media. See Configuring I/E Station Slots on
page 63.
Note: Cleaning cartridges, like all other cartridges used in the library,
must have a valid, readable barcode label properly installed
(see Supported Barcode Formats on page 338 and Installing
Barcode Labels on page 339).
3 Press Import.
The library moves the cleaning cartridge to a previously configured
cleaning slot.
Note: If not all cartridges appear on the screen, use the Page 1 of
x arrows to view the additional cartridges.
Exporting Cleaning When AutoClean is enabled (at least one cleaning slot has been
Cartridges configured), you can export one or more cleaning cartridges from
dedicated cleaning slots to the I/E station for removal from the library.
You may need to export expired cleaning cartridges or free up cleaning
slots for data storage.
After exporting cleaning cartridges, you can reduce the number of
configured cleaning slots. The extra slots become available for use as
storage slots. For information on configuring cleaning slots, see
Configuring Cleaning Slots on page 61. For a description of AutoClean,
see About AutoClean on page 164.
Note: If your library has zero I/E station slots, you cannot import or
export cleaning media. See Configuring I/E Station Slots on
page 63.
Operator Panel
1 Select Actions > I/E > Export Cleaning Tape.
2 Use the Up and Down buttons to select a cleaning cartridge to
export. You may also select ALL to export all cleaning cartridges;
however, the ALL option is only available if there are enough empty
slots in the I/E station to accommodate all the cleaning cartridges.
3 Press Export.
The library moves the selected cleaning cartridge to an I/E station
slot.
Web Client
1 Select Operations > Cleaning Media > Export.
The Operations - Export Cleaning Media screen displays. This
screen contains a list of the cleaning cartridges in the library. The
media barcode, location coordinates, media type, and cleaning
status (usable/expired) are displayed for each cartridge.
2 Note the number of empty I/E station slots that appear in the
Empty I/E Station Slots field on the right side of the screen. The
number of cleaning cartridges you can export is limited to the
number of empty I/E station slots.
Note: If not all cartridges appear on the screen, use the Page 1 of
x arrows to view the additional cartridges.
4 Click Apply.
The library moves the selected cleaning cartridge to an I/E station
slot.
Manually Cleaning Tape When a tape drive needs cleaning, it notifies the library. If the librarys
Drives AutoClean feature is not enabled (meaning, no cleaning slots have been
configured), the library generates a diagnostic ticket informing you that
the tape drive needs cleaning.
Details about manually cleaning tape drives include:
Be sure to unload the tape drive before attempting to clean it. If the
tape drive is loaded with a cartridge, it will not be available for this
operation.
Be sure to use a valid cleaning cartridge. If you use a data cartridge,
for example, the operation may complete but the tape drive will not
have been cleaned, and the library will issue a diagnostic ticket. See
Valid Cleaning Cartridges on page 164.
If you have at least one cleaning slot configured (see Configuring
Cleaning Slots on page 61), the library uses a cleaning cartridge
from either the topmost I/E station slot, or a configured cleaning
slot. If the cleaning cartridge is in the top I/E station slot and manual
cartridge assignment is enabled, assign the cleaning cartridge to the
System partition.
On the Web client, you can choose to use a configured cleaning
slot or the topmost I/E station slot. If two or more cleaning slots
are configured and have cleaning cartridges in them, the library
chooses which cleaning cartridge to use.
Operator Panel
1 Select Actions > Tape Drive > Manual Cleaning.
2 If more than one tape drive is in the library, use the Up and Down
buttons to select a tape drive to clean, then press Clean.
3 When the operation completes, press OK.
Web Client
1 Select Tools > Drive Operations.
2 Select Clean a tape drive and click Next.
3 If more than one partition exists, select the partition that contains
the tape drive you want to clean, and click Next.
The Clean Drive - Partition (Mode) screen displays, where Partition
is the name of the partition and Mode is the current mode (online/
offline) of the partition. This screen contains a list of tape drives
assigned to the partition.
4 If you have no cleaning slots configured, skip this step (you will use
the top I/E station slot as the source for your cleaning cartridge). If
you have at least one cleaning slot configured, you are asked to
Select Cleaning Source. Select which location to take the cleaning
cartridge from:
Use the top I/E slot Allows you to use a cleaning cartridge
from the topmost I/E station slot. Make sure to install a cleaning
cartridge in the topmost I/E station slot. If manual cartridge
assignment is enabled, assign the cleaning cartridge to the
System partition.
Use configured cleaning tapes Allows you to use a cleaning
cartridge from a configured cleaning slot. If two or more
cleaning slots are configured and have cleaning cartridges in
them, the library chooses which cleaning cartridge to use.
5 Select one or more tape drives to clean.
Note: If not all tape drives appear on the screen, use the Page 1
of x arrows to view the additional tape drives.
6 Click Apply.
7 Click OK to confirm it is OK to take the partition offline.
The library moves the cleaning cartridge to the tape drive and cleans
it. When finished, it moves the cartridge back to the cleaning slot or
I/E station.
Note: If a cartridge is already in the tape drive when you take the
tape drive offline, then the host can still read and write
data on the tape.
Some operations require that the tape drive be offline. You can take a
tape drive offline rather than the entire library or partition so as to
minimize disruption of library operations. A drive taken offline will
remain offline until you bring it back online, or until the library is
rebooted.This topic focuses on using the library user interface, not the
host application, to change the tape drive mode. Using the library to
change tape drive mode may affect the host application. See your host
application documentation for more information.
Details on changing the tape drive mode include:
The online/offline state follows the tape drive slot, not the particular
tape drive (if the tape drive were to be moved to a different slot in
the library).
You can select only tape drives in partitions to which you have been
given access.
If you change the mode of a control path tape drive to offline, a
caution dialog displays asking you to confirm the mode change. For
information on control path tape drives, see Configuring Control
Paths on page 67.
You can change the tape drive mode from both the operator panel and
the Web client.
Operator Panel
1 Select Actions > Tape Drive > Change Mode.
2 If more than one tape drive is in the library, use the Up and Down
buttons to select a tape drive.
3 Press Modify.
4 Use the Up and Down buttons to select Online or Offline.
5 Press Apply.
The new mode is displayed.
6 Press Exit.
Web Client
1 Select Operations > Drive > Change Mode.
The Change Drive Mode screen displays. This screen lists each tape
drives partition, location, state, current mode, activity, and version.
Note: If more than four tape drives are installed in the library, use
the Page 1 of x arrows to view the additional tape drives.
2 Locate the tape drive that you want to take offline or bring online.
In the tape drive table under Mode, the Current column indicates
the current mode of the partition. The New column contains an
Online/Offline button. The button toggles between modes.
3 Toggle the Online/Offline button to the desired mode.
4 Click Apply.
Step 1: Upgrade Upgrade your library and tape drive firmware to the latest released
Firmware versions.
Step 2: Install the EKM If your EKM license key is not already installed on the library, install it
License Key on the now (see Adding or Upgrading Licensable Features on page 69).
Library
Step 3: Install SKM on a You must use two key servers with SKM. You can purchase the two
Server or Servers servers from Quantum or provide your own. Follow the instructions that
came with your SKM system for installing SKM software on the servers.
Note: Make sure ports 80, 6000, and 6001 on the SKM servers are
opened up in a bi-directional mode. If they are not, the library
will not be able to communicate with the SKM servers.
Step 4: Configure Make sure to complete the above steps before proceeding.
Encryption Settings and
Key Server Addresses Note: You cannot edit the encryption system configuration settings
when any partition is enabled for library managed encryption.
If this happens, go to Setup > Encryption > Partition
Configuration, change all EKM partition settings from Enable
Library Managed to Allow Application Managed. Then make
your changes to the system configuration settings. Finally, go
back and change all the EKM partition settings to Enable
Library Managed.
Figure 31 Configuring
Encryption Settings and Key
Server Addresses
Note: While the setting is called SSL, the library actually uses
Transport Layer Security (TLS), a more secure successor to
SSL, to communicate with the encryption servers.
5 In the Primary Key Server IP Address or Host text box, enter either:
The IP address of the primary key server (if DNS is not enabled),
or
The host name of the primary key server (if DNS is enabled).
6 Port Number: The port number is always 6000. You cannot change
SKM port numbers.
7 Enter the IP address or host name of the secondary key server into
the Secondary Key Server IP Address or Host text box.
8 Click Apply.
Step 5: Install TLS Depending on when your library was manufactured, TLS certificates may
Communication already be installed. If they are not installed, you must install them. See
Certificates on the Installing TLS Certificates on the Library on page 186 for instructions on
Library how to verify whether they are installed, and how to install them.
Step 6: Run EKM Path Run the Manual EKM Path Diagnostics to be sure the library is
Diagnostics connected properly to both SKM servers. See Running Manual EKM Path
Diagnostics on page 183 for instructions.
Step 7: Configure SKM Encryption on the library is enabled by partition only. You cannot select
Partitions and Generate individual tape drives for encryption; you must select an entire partition
Data Encryption Keys to be encrypted.
Data written to encryption-supported and encryption-capable media in
EKM-supported tape drives will be encrypted unless data was previously
written to the media in a non-encrypted format. For data to be
encrypted, the media must be blank or have been written to using
library managed encryption at the first write operation at the beginning
of tape (BOT).
Configure the partition(s) as follows:
1 From the Web client, select Setup > Encryption > Partition
Configuration.
A list of all your partitions displays, along with a drop-down list
displaying the Encryption Method for each partition (see Figure 32).
Figure 32 Configuring
Partition Encryption
4 Click Apply.
Data encryption keys are generated. When you set the Encryption
Method to Enable Library Managed on a partition for the first
time, the library automatically triggers each SKM server to generate
a set of unique data encryption keys. This may take 15 minutes to
an hour or longer, depending on network performance. The library
notifies you when the process is complete.
5 Wait for the process to complete before resuming library
operations.
Caution: You must back up both SKM servers every time you
generate new data encryption keys to protect against
catastrophic server failure.
Step 8: Save the Library See Saving the Library Configuration on page 107 for instructions.
Configuration
Failure Scenarios If any of the tests fail, try the following resolutions and run the test
again to make sure it passes:
Ping Test Failure Verify that the key server host is running and
accessible from the network to which the library is connected.
Path Test Failure Verify that the key server is actually running
and that the IP address configured on the library is correct.
Check to see if there is a network configuration issue, such as a
firewall, preventing communication with the server.
Config Test Failure A database inconsistency has been
detected. Contact Quantum Support.
Running Manual EKM 1 Access the EKM Path Diagnostics screen in one of two ways:
Path Diagnostics Select Setup > Encryption > System Configuration or Setup
> Encryption > Partition Configuration and click the link that
says Click here to run EKM Path Diagnostics.
Enter library Diagnostics (from the Web client select Tools >
Diagnostics) and then select EKM > EKM Path Diagnostics.
Note that entering Diagnostics will log off all other users of the
same or lower privileges and take your partitions offline. When
you exit Diagnostics, the partitions automatically come back
online. See Performing Library Diagnostics on page 330 for
more information.
2 Click Apply.
3 The library performs the diagnostics and displays pass/fail results on
each of the tests in the Progress Window. This may take several
minutes. If a test fails, try the solutions listed under Failure Scenarios
on page 183.
4 Do one of the following:
If Completed appears in the Progress Window, the diagnostics
were performed (this does not mean that the diagnostics
passed, just that the diagnostics were performed). Click Close
to close the Progress Window.
If Failure appears in the Progress Window, the diagnostics were
not able to be performed.
Enabling Automatic You can enable the library to automatically perform EKM Path
EKM Path Diagnostics Diagnostics at selected intervals. During each interval, the library tests
every configured key server. The default test interval is 10 minutes. The
library generates a diagnostic ticket if there are problems.
Automatic EKM Path Diagnostics is enabled by default and should
always be left enabled. You should not need to disable it unless
Quantum Support directs you to do so.
For a list of tests performed, see EKM Path Diagnostics on page 182.
To enable Automatic EKM Path Diagnostics:
1 From the Web client, select Setup > Encryption > System
Configuration (see Figure 33).
2 Select the Automatic EKM Path Diagnostics check box.
3 Select a test interval from the Interval drop-down list.
Installing TLS Transport Layer Security (TLS) certificates are unique certificates that
Certificates on the must be installed on the library in order for the library to communicate
Library with Scalar Key Manager (SKM) servers.
If TLS certificates are not installed, you must install them. You can install
either Quantum-provided TLS certificates, or your own TLS certificates.
At any time, you may install a new set of TLS certificates to overwrite the
existing set. The new TLS certificates must all be valid or the overwrite
will not occur and the existing certificates will remain in place.
Tells you
whether TLS
certificates
are currently
installed on
the library
Note: You must be running SKM 1.1 or higher on your SKM servers in
order to install your own TLS certificates.
Note: If you install your own TLS certificates on the SKM server, you
must also install your own certificates on the library. Similarly, if
you use the Quantum-provided TLS certificates on the SKM
server, you must also use the Quantum provided TLS certificates
on the library. Newer libraries come with Quantum-provided
TLS certificates pre-installed. To verify whether TLS certificates
are already installed on the library, refer to Checking Whether
TLS Certificates are Installed on Library on page 186.
The same Root certificate must be installed on the SKM servers and
the library.
All the certificates have a valid validity period, according to the
librarys date and time settings.
Generating Data Caution: Every time you generate new data encryption keys, you
Encryption Keys must back up both SKM servers before you begin using the
keys to encrypt data. Refer to the SKM Users Guide for
instructions.
Note: Each library that you connect to an SKM server requires its own
set of data encryption keys. Each library only pulls data
encryption keys from the set that belongs to it. This means
that an SKM server may contain several distinct sets of data
encryption keys. When the data encryption keys for one library
have all been used, then more keys must be generated.
Figure 36 Changing
Encryption Method to Allow
Application Managed
Data encryption keys are generated. The library triggers the SKM
server to generate a set of unique data encryption keys. This takes
15 minutes to an hour or longer, depending on network
performance. The library notifies you when the process is complete.
Figure 37 Changing
Encryption Method Back to
Enable Library Managed
Sharing Encrypted Tape If you are using SKM, you can share encrypted tapes with other
Cartridges companies and individuals who also use SKM for managing encryption
keys.
Each SKM server provides a unique encryption key for each tape
cartridge that is encrypted. To read an encrypted tape in a library that is
attached to an SKM server that is different than the server that originally
provided the encryption key, the encryption key from the originating
(i.e., source) SKM server needs to be shared with the receiving (i.e.,
destination) SKM server. The key (or list of keys, if there is more than one
tape), is exported from the source SKM server to a file, which is sent to
the destination recipient. Each key contained in the file is encrypted
using the public key of the destination SKM server. The destination SKM
server provides its public key to the source SKM server as part of an
Encryption Certificate, which the source SKM server uses to wrap
(encrypt) the encryption keys for transport. Upon arrival, the file
containing the wrapped encryption keys can only be unwrapped by the
corresponding private key, which resides on the destination SKM server
and is never shared.
The process is as follows:
1 The destination administrator exports the Encryption Certificate that
belongs to the destination SKM server. The Encryption Certificate is
saved as a file to a location specified by the administrator on a
computer (see Exporting Encryption Certificates on page 197).
2 The destination administrator e-mails the Encryption Certificate file
to the source administrator.
3 The source administrator saves the Encryption Certificate file to a
location on a computer, and then imports the Encryption Certificate
onto the source SKM server (see Importing Encryption Certificates
on page 198).
4 The source administrator exports the Encryption Keys, assigning the
same Encryption Certificate noted above to wrap (encrypt) the keys.
The file containing the wrapped encryption keys is saved to a
location on a computer specified by the source administrator. See
Exporting Data Encryption Keys on page 199.
5 The source administrator e-mails the file containing the wrapped
encryption keys to the destination administrator.
6 The destination administrator saves the file containing the wrapped
encryption keys to a location on a computer, and then imports the
keys onto the destination SKM server (see Importing Data
Encryption Keys on page 201).
7 The destination library can now read the encrypted tapes.
For more information about the key servers and library managed
encryption best practices, please refer to the Scalar Key Manager Users
Guide.
Exporting Encryption To receive encryption keys from another SKM server, you must first send
Certificates your native encryption certificate to that server. The public key
contained in the certificate will be used to wrap (encrypt) the encryption
keys to protect them during transport to you.
This function is available to administrators and only applies to SKM
servers. Both SKM servers must be connected and operational in order
to import encryption keys.
To export an encryption certificate:
1 Before starting this process, read and follow the sequence of steps
outlined in Sharing Encrypted Tape Cartridges on page 195.
2 From the Tools menu, select EKM Management > Encryption
Certificate > Export. See Figure 38.
Figure 38 Exporting
Encryption Certificates
Importing Encryption The encryption certificate contains a public key that is used to wrap
Certificates (encrypt) encryption keys prior to transporting them to another SKM
server. When sharing tape cartridges, you need to import the encryption
certificate of the destination SKM server.
Figure 39 Importing
Encryption Certificates
Exporting Data SKM servers provide a unique encryption key for each tape cartridge
Encryption Keys that is encrypted. For another (i.e., destination) SKM server to read
tapes encrypted by your SKM server (i.e., source), you need to export the
encryption keys used to encrypt those tapes and send them to the
destination server.
Figure 40 Exporting
Encryption Keys
Note: The owner of that server should have sent you the
certificate and you should have imported it (see Sharing
Encrypted Tape Cartridges on page 195 and Importing
Encryption Certificates on page 198). The drop-down list
contains all of the encryption certificates that you have
ever imported onto your SKM server (indicated by the word
imported in the list), as well as the certificate belonging
to your SKM server pair (indicated by the word native in
the list).
Importing Data SKM servers provide a unique encryption key for each tape cartridge
Encryption Keys that is encrypted. In order to read tapes encrypted by a different (i.e.,
source) SKM server, you need to import the encryption keys used to
encrypt those tapes onto your SKM server (i.e., destination).
Caution: You must back up both SKM servers every time you
import data encryption keys to protect against
catastrophic server failure.
Accessing the SKM The SKM server logs contain information about all activities performed
Server Logs by the SKM servers. You should not need to retrieve these logs unless
Quantum Support directs you to do so. You can download the logs to
your computer or e-mail them to a recipient. In order to e-mail the logs,
the library e-mail account must be configured (see Configuring the
Library E-Mail Account on page 76).
The path to open the appropriate screen is as follows:
From the Web client, select Tools > EKM Management > Retrieve
SKM Logs.
Using the SKM This log lists the tape cartridges for which encryption keys failed the
Encryption Key Import most recent encryption key import operation. If you have only partial
Warning Log success when importing a file of encryption keys (meaning, some keys
import successfully but some keys do not), the library displays an
import warning message and generates a diagnostic ticket that
directs you to view this log to see which keys did not get imported.
For each key that failed the import, the log provides a message type that
is either:
Error The key could not be imported.
Warning The key was imported, but the metadata update failed.
For each key that failed the import, the log provides one of the
following message descriptions:
CRC Data Missing Error. Metadata is missing for the key. This
means that the export file is corrupt. Suggested Solution: Export
the key(s) for the listed tape cartridge(s) again, and then perform
the import operation again.
CRC Check Failed Error. The CRC data does not match the key or
key metadata. The export file is corrupt. Suggested solution: Try to
import the same file again. If this fails, export the key(s) for the
listed tape cartridge(s) again, and then perform the import
operation again.
Import To Primary/Secondary Server Failed Error. The key
import to the stated server failed (probably due to a network or
other connection issue). If the key failed to import to the secondary
server, it may have been imported successfully to the primary server.
Suggested solution: Check network connections and perform the
import operation again.
Key Metadata Update Failed (but key data was imported
successfully) Warning. The key was imported, but the metadata
update failed. You can access the key, but you cannot export it until
it is actually used in an encryption operation on the library.
Suggested solution: Use the key to read (decrypt) a tape. This
marks the key as used and updates the metadata, which will allow
you to export the key.
This log is only available if you are running SKM and have encryption key
management licensed on the library (see Adding or Upgrading
Licensable Features on page 69).
The log file is cleared and created new for each import operation so that
it shows only the key corruptions and import failures that occurred
during the latest encryption key import attempt.
For more information about library logs, see SKM Encryption Key Import
Warning Log (with EKM License) on page 219.
The path to open the appropriate screen is as follows:
From the Web client, select Reports > Log Viewer.
There are a number of informational screens and reports you can use to
get information about the library.
This chapter covers:
Viewing Library InformationViewing System Information
Viewing the Location of the Robot
Viewing the Library Configuration Report
Saving and E-mailing the Library Configuration Record
Viewing the Network Settings Report
Viewing the Logged in Users Report
Viewing the All Slots Report
Viewing, Saving, and E-mailing Library Logs
Viewing Library Information on the Operator Panel
Using Advanced Reporting Features
Viewing the Open Source License Agreement
Viewing the Copyright Statement
Web Client
Select Reports > About > Scalar i40/i80.
Operator Panel
1 Select Reports > About Library.
2 Press Next to scroll through all the screens. Press Exit to exit at any
time.
Web Client
Select Reports > System Information.
Note: The operator panel does not update the left side graphical
display until the motion is complete (success or failed)
Note: If you are viewing the alternate home screen, select Menu to
return to default home screen.
The triangle represents the robot. If it is filled in, then the robot
contains the media, otherwise the robot is empty. The direction
the triangle points to indicates its location.
The right information section provides the following:
Describes the current or last operation performed. If the
operation performed affects a device location, the description
will be numericfor example Move Media: [1,2,5] to [1,5,1]. If
the operation affects a slot location, such as unlocking a
magazine, the description will be textual for example, Unlock:
Left Magazine.
Provides the status of the operationActive, Completed, or
Failed.
2 For additional information about the status, select Details.
Web Client
1 Select Reports > Library Configuration. The Library Configuration
Report displays in a new window.
2 Do any of the following:
In the Legend, click a partition name to view information about
the partition.
Partition information:
Library information Number of partitions, number of
cleaning slots, number of unassigned slots, number of import/
export (I/E) slots, I/E manual assignment setting
Partition details Partition name, number of slots, number of
tape drives, and number of cartridges
Saving the Administrators can use the Tools - Save Configuration Record screen on
Configuration Record the Web client to e-mail the library configuration record.
You can only save the library configuration record from the Web client.
Web Client
1 Select Tools > Save Configuration Record.
2 Save the file to a known location on your computer.
E-mailing the Administrators can use the Tools - E-mail Configuration Record screen on
Configuration Record the Web client to e-mail the library configuration record.
Note: Do not enter more than one e-mail address in the E-mail
Address text box on the Tools - E-mail Configuration Record
screen. If you need to send the configuration record to multiple
e-mail addresses, repeat the procedure for each e-mail address.
Before you can e-mail the configuration record, the library e-mail
account must be configured. For information on setting up the e-mail
account, see Configuring the Library E-Mail Account on page 76.
You can only e-mail the library configuration record from the Web
client.
Web Client
1 Select Tools > E-mail Configuration Record.
2 Type an e-mail address into the E-mail Address text box.
3 Click Apply.
Web Client
Select Reports > Network Settings.
Web Client
Select Reports > Logged in Users. The report displays in a new
window.
Web Client
Select Reports > All Slots.
Cleaning Log The Cleaning Log shows all cleanings that have been performed in the
library. When the log reaches its maximum size, the oldest information
is replaced as new information is added.
The log provides the following information: Date Time (date and time);
Barcode (barcode of the cleaning cartridge); Tape (location coordinates
of the cleaning cartridge); Drive (location coordinates of the tape drive
that was cleaned); Status (pass/fail); Return Code (service use only),
Cleaning Type (Manual, Auto, MoveMedium), Expired (Invalid if the
tape is expired or a data tape was improperly used to clean; - if not
applicable); Usage Count (N/A if the cleaning did not complete);
Reserved.
Web Client
1 Select Reports > Log Viewer.
2 Select Cleaning Log and press Next.
The report displays in a new window for viewing.
3 You can save or e-mail the report following the on-screen
instructions.
Note: If you want to e-mail the log file to a recipient, type the
recipients name in the text box next to the E-mail button,
and then click the E-mail button. You must have your e-
mail notification configured in order to e-mail a log file.
See Configuring the Library E-Mail Account on page 76 for
more information.
Diagnostic Tickets Log The Diagnostic Tickets Log records all diagnostic tickets issued by the
library.
The log provides the following information: Num (ticket number to
provide a consecutive listing of tickets in the order issued; the first ticket
issued is assigned number 1, the second ticket 2, and so on); State
(open, unopened, closed); Priority (low, high, urgent); Created (date the
ticket was first issued); Last Updated (date the ticket was last issued);
Cause Code (the number assigned to the fault and which displays in the
full ticket name; for example, DT031- I/E Unlock Warning has cause code
31); Description; and Details.
Web Client
1 Select Reports > Log Viewer.
2 Select Diagnostic Tickets Log and press Next.
The report displays in a new window for viewing.
3 You can save or e-mail the report following the on-screen
instructions.
Note: If you want to e-mail the log file to a recipient, type the
recipients name in the text box next to the E-mail button,
and then click the E-mail button. You must have your e-
-mail account configured in order to e-mail a log file. See
Configuring the Library E-Mail Account on page 76 for
more information.
Media Security Log Note: To access the Media Security log, your library must have an
(with Advanced Advanced Reporting license. To learn more about the Advanced
Reporting License) Reporting license, refer to Advanced Reporting on page 14.
Media Usage Log (with Note: To access the Media Usage log, your library must have an
Advanced Reporting Advanced Reporting license. To learn more about the Advanced
License) Reporting license, refer to Advanced Reporting on page 14.
The media usage log lists media usage information regarding capacity
and read and write errors for media ever mounted in a drive., including
media that are no longer in the library. Refer to Viewing the Media
Usage Log on page 129.
SKM Encryption Key Note: To access the SKM Encryption Key Import Warning log, your
Import Warning Log library must have an Encryption Key Management (EKM)
(with EKM License) license. To learn more about the EKM license, refer to
Encryption Key Management on page 15.
Lists keys that failed the most recent data key import operation. This log
is only available if you are running Scalar Key Manager (SKM). For
detailed information about this log, see Using the SKM Encryption Key
Import Warning Log on page 202.
Web Client
1 Select Reports > Log Viewer.
2 Select SKM Encryption Key Import Warning Log and press Next.
3 The report displays in a new window for viewing.
Note: If you want to e-mail the log file to a recipient, type the
recipients name in the text box next to the E-mail button,
and then click the E-mail button. You must have your
e-mail account configured in order to e-mail a log file. See
Configuring the Library E-Mail Account on page 76 for
more information.
Tape Drive Log The library allows you to retrieve tape drive logs using the Web client.
Tape drive log information can be used to help troubleshoot the library,
the tape drive sled, and tape drive issues.
Since the log retrieval process can take up to 30 minutes, the tape drive
and associated partition are automatically taken offline during the
operation and brought back online when the operation completes. You
will be asked to confirm that you want to take the tape drive and
partition offline.
Tape drive log files adhere to the following naming convention:
UDS_ID_SN.DMP, where ID identifies the tape drive coordinate location
within the library and SN identifies the tape drive serial number.
Web Client
1 Select Tools > Drive Operations.
2 Select Retrieve tape drive log and click Next.
3 If your library contains multiple tape drive interface types, select the
interface type of the tape drive from which you want to retrieve logs
and click Next.
4 The Retrieve Drive Log screen displays. This screen lists the available
tape drives.
5 Select a tape drive from which you want to retrieve logs and click
Next.
Note: If there is more than one page of tape drives, use the Page
1 of x arrows to view the additional tape drives.
6 Click Apply.
A dialog displays asking you to confirm you want to take the
partition offline.
7 Click OK.
The Progress Window displays, displaying information on the
action, elapsed time, and status of the operation.
8 If the Progress Window displays a completed message, you can
close the window and save the file to your computer.
9 If the screen displays a failure message, the tape drive log was not
successfully retrieved. Follow the instructions listed in the Progress
Window to resolve any issues that occurred during the operation. If
a complete tape drive log could not be retrieved, you may still be
able to access a partial log. If so, a note will appear stating, A
complete tape drive log could not be retrieved, but a partial log is
available and may be saved for further analysis once the progress
window is closed.
Viewing Partition The operator panel provides an overview of partition information. For
Information each partition, you can see the following information:
Online/offline mode
Control path tape drive location coordinates
Number of tape drives
Number of storage slots
Operator Panel
1 Select Reports > Partitions.
2 If the library contains more than one partition, use the Up and
Down buttons to select a partition and press Select.
Viewing Tape Drive The operator panel provides an overview of tape drive information. For
Information each installed tape drive, you can see the following information:
Online/offline mode
Partition to which the tape drive is assigned
Whether the tape drive is the control path for the partition
State (ready/active/mounted)
WWNN (if Fibre Channel) or SAS address (if SAS)
Operator Panel
1 Select Reports > Tape Drives.
2 If the library contains more than one tape drive, use the Up and
Down buttons to select a tape drive and press Select.
Viewing Network A short report on the operator panel displays the librarys network
Settings settings: host name, IP address, and network configuration.
Operator Panel
1 Select Reports > Network Settings.
2 If IPv6 is enabled, the IPv4 information is shown on the first screen.
Press Next to see the IPv6 address information on the next two or
more screens. Although the library can have unlimited IPv6 address,
a maximum of three are shown in this report.
Viewing the Date, Time, The operator panel displays the current date, time and time zone
and Time Zone configured on the library.
Operator Panel
Select Reports > Date/Time.
Viewing Licenses The operator panel displays a list of all the licenses currently installed on
the library: number of COD slots licensed, number of unlicensed slots,
and whether Advanced Reporting is licensed.
Operator Panel
Select Reports > Licenses.
Web Client
Select Reports > About > Open Source Licenses.
Operator Panel
Select Reports > Copyright Statement.
Web Client
Available in the Web client online help. To view the help, click the Help
icon in the upper right corner of the screen.
WARNING: Two people are required to lift and install the library.
Caution: Use care when handling the fibre optic cables. Do not
crimp or bend the cables. Do not exceed the bend
radius specified by the manufacturer.
2 Connect an Ethernet cable (not supplied with your library) into the
LEFT port on the system control board (SCB). The right SCB port is
for service use only; do not use. Connect the other end of the
Ethernet cable into a live Ethernet jack connected to your network.
3 Connect the power supply cord into the power supply connector.
Plug the other end of the cord into a grounded AC outlet.
Figure 42 Connection
Locations
Filler plate
Filler plate
The instructions for installing the rails are the same for both the Scalar
i40 and the Scalar i80.
Caution: Make sure the rack mounting rails are level, both left to
right and front to back. If the library is not level in the rack,
it will not work properly.
Supported Rack Types The Scalar i40 and Scalar i80 libraries are designed to fit in most
standard 19-inch equipment cabinets, including:
Dell, 08P157 (US-08P157910-3AU-0900),square, 2.48 - 2.72 mm
thick
SUN, 38U, NGR900R, M6
Emcor, 10 Series, round hole
IBM, Machine Type 9306, Model 900, square, 28.25-inch deep, 2.0-
2.25 mm thick
HP, 10K, PN 245169-001, Asm 10642U GR Metallic, square, 2.0-
2.2 mm thick
EMC CX500
Rittal Cable Tester Rack Frame, square
Rack depth of 34 in. (86.3 cm) minimum is recommended; however,
rack depths of 24 to 36 in. (60.9 to 91.4 cm) are supported.
Rack Mount Kit The following items are included in the rack mount kit:
Contents
2 Shelf
2 Shelf Extender
Installing the Rack Before installing the rack mount shelves, you must collect the following
Mount Shelves information:
Type of rack mount rails (square hole, through hole, or threaded
hole)
Depth of rack
1 Assemble the rack mount shelves included in the accessory kit (left
and right):
a The holes used to attach the two halves of the rack mount
shelves differ depending on the depth of the rack (see Figure 43
on page 233). It is recommended that you use the ones that are
exposed and have the widest spacing.
Rear of rack
depths of 24 in (60.9
cm) to 28 in (71.1 cm)
depths of 27 in (68.5
cm) to 36 in (91.4 cm)
Rear of rack
Figure 44 Assembling the Left The metal fold T-nuts must be oriented as
and Right Rack Mount Shelves must be toward shown to properly fit in the
the outside of shelf adjustment slot
the shelf as r
de
Back of rack
shown
ten
Ex
T-nuts
elf
t sh
un
Front of rack
k mo M5 x 10 screws
rac
ide
f t -s
Le
T-nuts must be
oriented as shown
to properly fit in
the shelf
The metal
adjustment slot
fold must
Ex be toward
te n
de the
r
Back of rack
outside of
the shelf
as shown
T-nuts
Rig
ht
M5 x 10 screws -si
d er
ac
k mo
un
ts
he
lf
c Determine the type of rail adapter required for your rack. Each
rail adapter is marked with the specific hole type supported (see
Figure 45).
d Attach the appropriate rail adapter to the front and back of the
rack mount shelves (right and left) with 2 M5 x 10 screws per
adapter (see Figure 46).
M5 x 10
elf screws
sh
ft
Le
Rail adapter M5 x 10
screws Arrow must
point up
Rail adapters
M5 x 10
screws
Rig
ht
sh
elf
M5 x 10
screws
2 Install the left and right rack mount shelves into the rack (the rack
mount shelves adjust 24 to 36 in.) and secure with the following
parts in four locations (see Figure 47 on page 238):
2 washers
2 M4 x 12 screws
Note: The rack mount shelves must be installed on the inside rack
rails.
Washers
M4 x 12
screws
Left shelf
Right shelf
3 Once the rack mount shelves are secured to the rack, tighten the
screws securing the adjustable shelves (right and left) together (see
Figure 48).
4 If the rack does not have threaded holes, install a clip nut or a cage
nut in the back side of the rail, in the first empty hole below the rail
adapter. This is what you will screw the library thumbscrews into to
secure the library in the rack. See table below for type of nut, and
Figure 49 on page 241 for installation location.
Clip nut
Rail adapter
Caution: Make sure the rack mounting rails are level, both left to
right and front to back. If the library is not level in the rack,
it will not work properly.
WARNING: At least two people are required to lift and install the
library.
1 If tape drives are installed in the library, you may wish to remove
them to reduce weight. To remove tape drives, unscrew the captive
thumbscrews securing them to the back of the library and slide
them out of the library. Set them down gently on a stable surface.
2 Lift the library, place it on the rack shelves, and slide it into the rack
as far as it will go.
3 Open one of the magazines slightly to access the captive
thumbscrew that is attached to the library chassis. You will use this
thumbscrew to secure the library to the rack. To open the magazine,
insert the magazine lock override tool into the access hole in the
bottom of the magazine bezel (see Figure 50 on page 242). Use the
tool to depress the release latch while gently pulling outward on the
magazine bezel handle.
Right-side magazines will only slide out as far as the I/E station (one
column of slots). To release the right-side magazines fully:
On the Scalar i40 and the bottom right magazine of the Scalar
i80, reach under the open magazine and insert the tool directly
into the access hole in the library chassis to depress the release
latch, while pulling out on the magazine bezel handle.
On the top right magazine of the Scalar i80, reach under the
open magazine and press the release latch directly with your
finger, while pulling out on the magazine bezel handle.
WARNING: At least two people are required to lift the library and
remove it from a rack.
1 Shut down the library by selecting Actions > Shutdown from the
operator panel.
2 Turn OFF the library by pressing the power button on the front
panel.
3 Disconnect the power supply cord, the Ethernet cable, and all tape
drive cables from the back of the library. If you have multiple tape
drives, label the cables so you can reconnect them to the correct
tape drives later.
4 Remove all the tape drives from the library (for details, see
Removing and Replacing a Tape Drive on page 286).
5 Remove all the magazines from the library (for details, see Removing
and Replacing a Magazine on page 271).
6 Unscrew the captive thumbscrews in the rack ears that secure the
library to the rack (see Figure 51 on page 243).
7 Slide the library out of the rack. Keep the library level as you slide it
out of the rack.
8 Place the library on a flat, stable surface.
Scalar i40
Scalar i80
Kit Contents
Item Quantity
Top cover 1
Rubber feet 8
Procedure WARNING: Two people are required to safely lift the library.
7 Install the side panels one at a time (in any order) as follows (see
Figure 55 on page 251):
a Orient the side panel correctly. They are all the same but can
only be installed one way. Line up the eight posts on the inside
of the side panel with the holes in the side wall of the library.
Line up the screw hole in the bottom front of the side panel
with the captive thumbscrew behind the magazine on the
library chassis.
b Press the side panel against the wall so that the posts go into
the holes.
c Slide the side panel toward the front of the library about half an
inch until it stops and the posts are engaged in the holes. The
side panel should be flush with the side of the library chassis.
d Tighten the thumbscrew at the front of the library to secure the
side panel to the library.
The procedure is similar for the Scalar i40 and the Scalar i80. Pictures
of the Scalar i40 also apply to the Scalar i80.
You may perform this procedure with library power ON. If you do, be
careful not to accidentally press the power button and turn the library
off when installing the bezel.
Read these instructions completely before beginning.
Installed in a rack high enough Unscrew all the thumbscrews that secure the library to
to access to the bottom bezel the rack (the Scalar i40 has two thumbscrews; the
screws Scalar i80 has four). See Figure 58 on page 256.
Installed in a desktop kit Release the desktop cover by removing two screws at
rear of the desktop cover, then slide the desktop cover
toward the back of the library two or three inches.
Installed very low in a rack so Remove the library from the rack (see Removing the
that you cannot access the Library From a Rack on page 243).
bottom bezel screws unless you
remove the library from the
rack
4 Slide the library one-to-two inches forward out of the rack or over
the edge of the table or desk in order to access the two bottom
bezel screws.
WARNING: Only slide the library out far enough out to access the
two screws on the bottom of the library. The library is
not secured in the rack or on the desk. Pulling it out
too far could cause the library to slide out of the rack
or off the desk.
5 Make sure all the magazines are pulled out a few inches (or
removed) to allow you to remove and install the bezel without
damaging it.
6 Remove and set aside the two screws securing the bezel to the
bottom of the chassis (see Figure 57 on page 255).
7 Remove and set aside the two screws securing the bezel to the top
of the chassis (see Figure 58 on page 256).
Bottom
bezel
screws
Thumbscrew
securing library
to rack
9 Install the new bezel straight onto the library. Do not tip or twist the
bezel. If magazines are still in the library, be careful not to scratch or
damage the bezel as you install it. Slide the top and bottom edges
of the bezel to the inside of the top and bottom layers of the chassis
sheet metal. On the Scalar i80, press in near the center on both
sides of the bezel until you hear it snap into place (see Figure 59
for locations).
Caution: Make sure the power button and all four operator
panel control buttons appear through the holes in the
bezel and are not trapped beneath the bezel.
10 Install the two top screws, then the two bottom screws.
11 Reinstall the library in the rack or desktop kit.
12 Close all the magazines.
13 If you turned the library off to perform this procedure, turn it ON
now by pressing the power button on the front panel. Wait until the
library initializes before resuming library operations.
14 If you removed the library from the rack to perform this procedure,
run the Installation and Verification Test (IVT) to ensure the Y-tray,
tape drives, and magazines are all functioning properly. From the
operator panel, select Tools > IVT and follow the instructions on
the screen. The IVT takes about 30 minutes. See Running the
Installation and Verification Test (IVT) on page 325 for more
information about the IVT.
WARNING: Two people are required to safely lift the library into and
out of its packaging, a rack, or a desktop kit.
When you replace a library chassis, you will remove all the components
from your existing library and install them in the new library.
Procedure When you replace a library chassis, you will remove all the components
from your existing library and install them in the new library.
1 Unpack the new library chassis and place it on a flat, level surface.
See the instructions in Chapter 2, Unpacking the Library for specific
unpacking instructions, particularly about removing the Y-tray
restraints.
2 Verify that the new chassis is the same type (Scalar i40 or Scalar
i80) as the unit you are replacing.
3 If you had license keys installed on your library, you will need to
install new ones on the replacement library. Contact Quantum
Support to request new license keys.
4 If the library you are replacing is still turned on and operational,
shut down the library by selecting Actions > Shutdown from the
operator panel.
5 Turn OFF the library by pressing the power button on the front
panel.
6 Disconnect the power supply cord, the Ethernet cable, and all tape
drive cables from the back of the library. If you have multiple tape
drives, label the cables so you can reconnect them to the correct
tape drives later.
7 Remove all of the following components from the library (see
Figure 60 on page 261).
Component to
Remove Instructions
Power Supplies
Caution: Make sure the power supply is unplugged and disconnected
from live power before you remove it.
1 Disconnect the power cord from the back of the power supply.
2 Unscrew the captive thumbscrews.
3 Pull outward on the power supply handle to remove it from the library.
Component to
Remove Instructions
Tape Drives 1 Label each tape drive with its location in the library slots. It is
recommended that you reinstall the tape drives in the same location in the
new chassis.
2 Unscrew the captive thumbscrews securing the tape drive sled to the back
of the library. Half-height tape drives have two thumbscrews. Full-height
tape drives have four thumbscrews.
3 Using the handle, pull the drive sled out of the library. It should slide out
smoothly and easily.
Filler Plates Remove all filler plates (tape drive and power supply).
1 Unscrew the two captive thumbscrews.
2 Pull the filler plate out.
Magazines 1 If your library is a Scalar i80, label the magazines so you can reinstall them
in the same slots.
2 Insert the magazine lock override tool into the access hole in the bottom of
the magazine bezel.
3 Use the tool to depress the release latch while gently pulling outward on
the magazine bezel handle. If the magazine is on the right side, it will only
slide out as far as the I/E station. To release the magazine fully:
On the Scalar i40 and the bottom right magazine of the Scalar i80, reach
under the open magazine and insert the tool directly into the access
hole in the library chassis to depress the release latch, while pulling out
on the magazine bezel handle.
On the top right magazine of the Scalar i80, reach under the open
magazine and press the release latch directly with your finger, while
pulling out on the magazine bezel handle.
Figure 60 Components to
Remove
To remove the library from a desktop kit, remove the two top
cover screws at the rear of the top cover. Loosen the captive
thumbscrews on the library chassis that are attached to the side
panels of the desktop kit. Slide the side panels one-half inch
toward the rear of the library to disengage the side-panel posts
from the library wall, then pull the side panels off.
c Remove the orange shipping restraint tab and discard. You will
not need to use it again.
Note: The robot may stay at the top of the library, or it may
move downward toward the floor of the library. If it
moves downward, you will hear the gears turning as it
moves. This is normal.
11 If desired, you may cover the holes in the replacement library top
cover with stickers, which are provided in the accessory kit for this
purpose. This step is optional and is intended to prevent small
objects from accidentally falling into the library through the holes.
12 Install the new chassis in a rack or desktop kit. For instructions, see
Installing the Rack Mount Kit (Rail Kit) on page 229 or Installing the
Library in a Desktop Kit on page 244.
13 Install the components you removed from the old chassis into the
new chassis.
Component to
Install Instructions
System Control Install the SCB before you install the power supply.
Board (SCB) 1 Position the SCB for installation: The board components face up. The flat
part of the board faces down. The thumbscrews are on the upper side of
the SCB back plate.
2 Install the new SCB by pushing the SCB into the slot until it stops. It should
slide smoothly and easily. When it reaches the end of its travel, press firmly
on the back panel of the SCB to snap it into place.
3 Tighten the two thumbscrews finger tight.
4 Connect the Ethernet cable to the LEFT Ethernet port (as viewed from the
back of the library; see Figure 63 on page 267).
Power Supplies If your library is a Scalar i80 and you have only one power supply, install it in
the top slot. If you have two power supplies, install them both.
Caution: Make sure the power supply is unplugged and disconnected from
live power before you install it.
1 Push the power supply straight into the slot. You may need to press firmly
on the power supply sheet metal at the very end to plug in the power
supply to the connector on the library. You will feel it snap into place.
The power supply only goes in one way, and should slide in easily. If you
cannot slide it in, you may be trying to install it upside down.
2 Tighten the two thumbscrews finger tight.
3 Connect the power cord to the power supply.
4 Plug the power cord into a grounded AC outlet.
Component to
Install Instructions
Tape Drives 1 Insert the tape drives into the same drive slots they were in the old chassis.
The shelf on the bottom of the drive sled fits into the notch in the library
chassis and slides on the plastic guide rails. The tape drive must be level to
slide in smoothly. At the very end of the slide, you will feel a slight click as
the tape drive sled connector connects into its mating connector in the
library chassis.
2 Tighten the tape drives captive thumbscrews finger tight to secure the tape
drive to the library chassis.
3 Connect all tape drive cables as they were in the old unit. Make sure they
are connected to the host or switch as they were before. For full-height
Fibre Channel tape drives, the cable must go in the LEFT connector (as
viewed from the back of the library; see Figure 63 on page 267).
Filler Plates Make sure every empty power supply slot and tape drive slot is covered with a
filler plate.
1 Slide the filler plate into the slot.
2 Tighten the thumbscrews.
Magazine Slide each magazine into its slot and push it in all the way until it stops.
Figure 63 Reinstalled
Components
Power
supply cord
Power
supply cord
Removing and The filler plate is half-height in size. If you remove a full-height tape
Installing a Tape Drive drive, you must install two filler plates to cover the opening.
Filler Plate
Removing a tape drive filler plate
1 Unscrew the two captive thumbscrews and pull the filler plate out.
2 Save the filler plate in case you need to use it again.
Removing and The power supply filler plate is used only on the Scalar i80 when only
Installing a Power one power supply is present.
Supply Filler Plate
Removing a power supply filler plate
1 Unscrew the two captive thumbscrews.
2 Pull out on the thumbscrews so the filler plate is at a slight angle
and the bottom of the filler plate is still attached in the slot.
3 Lift the filler plate up to disengage the catch at the bottom and pull
the filler plate out of the slot.
Single
power
supply
installed
in top
slot
Power
supply
filler
plate
The procedure for replacing magazines is the same on the Scalar i40
and the Scalar i80.
Creating a Backup Map When you transfer tape cartridges from the removed magazine into the
of Cartridge Locations replacement magazine, each cartridge needs to go in the same slot
position it was in previously. One way to do this is to transfer the
cartridges one by one from one magazine to the other. However, if the
cartridges get mixed up or dropped, you need a backup method to
know where to place your cartridges. The library configuration report
provides a convenient backup map.
1 On the Web client, select Reports > Library Configuration.
2 Click the Show Barcodes button.
The screen displays a map of the library showing the location of
each cartridge, by barcode.
3 Click the print icon in the upper right corner to print the report.
Alternatively, take a screen capture of the report and save or print it,
or copy the map by hand.
Removing the You can perform this procedure with library power on.
Magazine from the 1 From the operator panel, select Actions > Magazine.
Library
2 Use the Up and Down buttons to select the magazine you want to
remove and press Release.
3 Wait for the operator panel to display the message: Magazine is
now unlocked. Waiting for the magazine to be moved to the
expected position.
4 Pull out on the magazine bezel handle and remove the magazine
from the library. If you do not remove the magazine within 30
seconds, the magazine locks again.
Note: If the library is turned off, you can release the magazine
manually by inserting an opened paperclip, small screwdriver,
or other object (3.5 mm or less in diameter that will not break
off) into the access hole in the bottom of the magazine bezel
(see Figure 65). Use the tool to depress the release latch while
gently pulling outward on the magazine bezel handle.
Right-side magazines will only slide out as far as the I/E station.
To release right-side magazines fully:
On the Scalar i40 and the bottom right magazine of the
Scalar i80, reach under the open magazine and insert the tool
directly into the access hole in the library chassis to depress the
release latch, while pulling out on the magazine bezel handle.
On the top right magazine of the Scalar i80, reach under the
open magazine and press the release latch directly with your
finger, while pulling out on the magazine bezel handle.
Installing the Magazine The replacement magazine can be used on either the left or right side of
the library, depending on how it is oriented. Once it is oriented correctly,
the left or right bezel can be attached.
You can perform this procedure with the library powered on.
1 Place the removed magazine in the orientation it would be if it were
installed in the library.
2 Place the replacement magazine next to the removed magazine in
the same orientation. Make sure they look the same from all angles.
The storage slots face inward.
On the outer wall of the magazine, the silver rollers sit below
the springs (see Figure 66).
Silver rollers
Note: If you try to install the wrong bezel, it will not fit and you
will not be able to install it.
4 Push up on the top bezel tabs and fit them over the posts on the
top of the magazine. Turn the magazine over and repeat on the
bottom (see Figure 67 on page 275).
5 Install the two washers and two M3 screws securing the top of the
bezel to the magazine. Install them in the outer hole in each tab
(see Figure 67 on page 275).
6 Turn the magazine over and install the two washers and two M3
screws securing the bottom of the bezel to the magazine. Install
them in the outer hole in each tab (see Figure 67).
Figure 67 Removing/Installing
the Magazine Bezel
Bezel
Tab
The Scalar i40 contains one power supply. The Scalar i80 can have up
to two power supplies for redundancy purposes.
An unused power supply slot must be covered by a filler plate.
This document covers:
Replacing a Power Supply in a Single-Power-Supply System (Scalar
i40 and Scalar i80)
Adding or Replacing a Redundant Power Supply on the Scalar i80
Replacing a Power Note: If you have a single power supply in a Scalar i80, it is
Supply in a Single- recommended that you install it in the upper slot, to provide
Power-Supply System better temperature control (see Figure 68).
(Scalar i40 and Scalar
i80) 1 Shut down the library (from the operator panel, select Actions >
Shutdown > Shutdown Library). Wait for the screen to prompt
you to turn off library power.
2 Turn OFF library power by pressing the power button on the front
panel. Wait for the operator panel screen to turn off.
3 Disconnect the power cord from the power supply.
Caution: Make sure you disconnect live power from the power
supply before you remove or install it. Otherwise,
damage to the power supply could occur.
Adding or Replacing a You do not need to turn off library power to perform this procedure.
Redundant Power 1 If you are adding a new power supply to a Scalar i80, remove the
Supply on the filler plate and start at Step 6 below.
Scalar i80
2 If you have two power supplies, determine which one to remove.
Caution: Make sure you remove the power supply whose LED is
red or off. Do not remove the power supply whose LED
is green.
3 Disconnect the power cord from the power supply you want to
remove.
Caution: Make sure you disconnect live power from the power
supply before you remove or install it. Otherwise,
damage to the power supply could occur.
The power supply only goes in one way, and should slide in easily. If
you cannot slide it in, you may be trying to install it upside down.
7 Tighten the two thumbscrews finger tight.
8 Connect the power cord to the power supply.
9 Make sure the power cord is plugged in to a grounded, AC outlet.
The power supply LED should turn green immediately to indicate
the library is turned on.
If the power supply LED is red, the power supply is not working.
Contact Quantum Support.
Note: When you replace the SCB you will permanently lose all data
previously collected for logs and reports.
Replacing the System Caution: You must completely remove power from the library before
Control Board removing and replacing the system control board.
Thumbscrews
Thumbscrews
Ethernet port
Scalar i80
Installing Library 1 Connect the power cords to the power supplies on the back of the
Firmware library. Make sure that each power supply is plugged in to a
grounded, AC outlet.
2 Turn ON the library by pressing the power button on the front
panel.
The LED on the SCB should illuminate green.
The green power LED on the library front panel above the power
button illuminates, and the operator panel screen turns on. The
library goes through a connection and initialization sequence that
takes up to 60 seconds.
Restoring the Library Follow the instructions in this section if you have a saved library
Configuration configuration that you want to reinstall on the library.
1 On the operator panel, press Cancel to exit the Setup Wizard.
2 Take note of the librarys IP address (on the operator panel, select
Reports > Network Settings).
3 Access the Web client using the IP address and log in using the
default user name and password:
User name: admin
Password: password
Note: Once you restore the configuration, all your former user
names and passwords are restored.
d Click Apply
e Click OK.
5 Check the librarys date, time, and time zone settings and
reconfigure if necessary. From the Web client, select Setup > Date
& Time.
6 If you changed the IP address from what it was originally, update
host and other applications that access the library.
7 Save the library configuration. From the Web client, select Tools >
Save/Restore Configuration. Select Save Configuration and click
Apply. Save the configuration to a known location.
8 It is recommended that you run the Installation and Verification Test
(IVT). From the operator panel, select Tools > IVT and follow the
instructions. The IVT takes about 30 minutes. If any problems are
detected, the library issues a diagnostic ticket.
9 Package the old SCB in the packaging that shipped with the new
SCB and send the old SCB back to Quantum using the included
return shipping label.
Manually Reconfiguring Follow the instructions in this section if you do not have a saved library
the Library configuration.
1 If you had licenses installed on your library, have the license keys
handy so you can install them on the library. If you no longer have
them, you can obtain them at http://www.quantum.com/
licensekeys, or from Quantum Support.
2 When the firmware update is complete, the Setup Wizard displays
on the operator panel screen. The Setup Wizard helps you configure
the date, time, IP address, IPv6 enable/disable, licenses, partitions,
I/E slots, and cleaning slots.
Note: You cannot update the host name or time zone on the
operator panel. If the displayed host name or time zone is
incorrect, change it later using the Web client (see Step 8
on page 285).
4 Take note of the librarys IP address (on the operator panel, select
Reports > Network Settings).
5 Access the Web client using the IP address and log in using the
default user name and password.
6 Optionally, install tape drive firmware for autoleveling. The library
firmware contains baseline tape drive firmware for autoleveling.
Verify your tape drive firmware is at the level you expect. If not:
a Upload the tape drive firmware you want to use. From the Web
client, select Tools > Drive Operations > Upload/remove tape
drive firmware for autoleveling.
b Unload all tape cartridges from the tape drives on which you
want to autolevel firmware.
c Initiate autoleveling by doing one of the following:
Restart the library (from the operator panel, select Actions
> Shutdown > Restart Library.
Restart all the tape drives you want to autolevel, as follows:
From the Web client, select Tools > Diagnostics. Confirm
you want to take the partitions offline. Select Drives >
Drive Tests > Drive Reset. Select the applicable partitions
and tape drives, then click Apply, then click OK.
7 If you changed the IP address from what it was originally, update
host and other applications that access the library.
8 Update the library name, time zone, and any other configuration
settings, if required, using the Web client Setup menus.
9 If you are connecting to a Scalar Key Manager (SKM), take note that
TLS certificates will need to be loaded onto the library. See
Installing TLS Certificates on the Library on page 186 for
instructions.
10 Save the library configuration. From the Web client, select Tools >
Save/Restore Configuration. Select Save Configuration and click
Apply. Save the configuration to a known location.
11 To ensure the library is fully functional with the new SCB installation
and configuration selections, we recommend you run the
Installation and Verification Test (IVT). From the operator panel,
select Tools > IVT and follow the instructions. The IVT takes about
30 minutes. If any problems are detected, the library issues a
diagnostic ticket.
12 Package the old SCB in the packaging that shipped with the new
SCB and send the old SCB back to Quantum using the included
return shipping label.
Caution: Do not remove the tape drive from the drive sled.
Note: For multiple tape drive installs in which you are changing
control paths, install and verify the tape drives one at a time,
rather than all at once.
Preparing Partitions Depending on the types of tape drives you are removing and installing,
and Control Paths you may need to reconfigure library partitions or change the control
path before you remove and replace the tape drive. There are four
different types of installation, described in the table below. Follow the
instructions in the table before proceeding to the remove/install
procedures.
Replacing tape drive that is Install the replacement tape drive in the same slot as the removed
assigned to a partition with tape drive.
a tape drive that has the There are no special instructions unless the tape drive you are
same: replacing is the control path in a partition with multiple tape drives,
interface type (Fibre and you want the partition to remain online during the replacement
Channel or SAS), and procedure. In this case, select another tape drive as the control path.
form factor (half-height or From the Web client, use the Setup > Control Path menu path.
full-height), and
vendor
Replacing a tape drive that is If the partition contains only one tape drive, delete the partition
assigned to a partition with before removing the tape drive and then re-create the partition
a tape drive that has a once you install the replacement tape drive.
different: If the partition contains multiple tape drives and the tape drive you
interface type (Fibre want to replace is not the control path, delete the tape drive from
Channel or SAS), or the partition.
form factor (half-height or If the partition contains multiple tape drives and the tape drive you
full-height), or want to replace is the control path, select another tape drive as
vendor the control path. Then delete the tape drive you want to replace
from the partition.
To delete tape drives from partitions, select Setup > Partitions from
the Web client.
To modify the control path, select Setup > Control Path from the
Web client.
Removing a Tape Drive Caution: Do not remove a tape drive that is currently performing an
from the Library operation.
1 Make sure the tape drive you want to remove is empty of media.
From the operator panel, select Actions > Tape Drive > Unload.
2 Take the tape drive you want to remove offline. From the operator
panel, select Actions > Tape Drive > Change Mode. Select the
tape drive and press Modify. Press the Down button to select
Offline, then press Apply.
3 Disconnect the cable from the back of the tape drive.
4 Unscrew the captive thumbscrews securing the drive sled to the
back of the library. Half-height tape drives have two thumbscrews.
Full-height tape drives have four thumbscrews.
5 Using the handle, pull the drive sled out of the library. It should slide
out smoothly and easily.
6 Wait at least 10 seconds before installing a replacement tape drive
to allow the library to recognize that the tape drive has been
removed.
7 Install a replacement tape drive following the instructions below. If
any empty slots remain, install a filler plate in the empty slot.
8 If you are returning the tape drive to Quantum, wrap it in the
antistatic bag in which the replacement tape drive is wrapped, then
finish packing it in the same packaging materials from the
replacement tape drive. Ship the tape drive to Quantum using the
RMA materials included in the packaging.
Figure 71 Acceptable
Installation Locations for Full-
Height Tape Drives
Installation Procedure
1 If you need to remove one or more filler plates, unscrew the two
thumbscrews securing the filler plate to the back of the library.
Holding the thumbscrews, pull the filler plate gently out of the
library. Save the filler plate in case you need to use it in the future.
2 Insert the tape drive into the drive slot. The shelf on the bottom of
the drive sled fits into the notch in the library chassis and slides on
the plastic guide rails (see Figure 72 on page 290). The tape drive
must be level to slide in smoothly. At the very end of the slide, you
will feel a slight click as the tape drive sled connector connects
into its mating connector in the library chassis.
Notch in library
chassis
11 Run the tape drive diagnostic test on the newly installed tape drive
to be sure it is functioning correctly.
a Install a scratch tape in the top I/E station slot.
b If manual cartridge assignment is enabled, assign the scratch
tape to the System partition.
c From the operator panel, select Tools > Diagnostics.
d Continue through the next few screens to run the tape drive test
on the replaced tape drive.
If a problem is found during testing, you receive a diagnostic ticket.
See Running the IVT Diagnostic Subtests Individually Robotics,
Tape Drive, and Magazine Tests on page 327 for more information.
12 Save the library configuration (see Saving the Library Configuration
on page 107).
Creating a Backup Map You must remove all the tape cartridges before shipping the library. If
of Cartridge Locations you want to maintain the same partitions and magazine slot
assignments in your new location as you are using currently, you will
want to reinstall your tape cartridges in the same slots they are in now.
The library configuration report provides a convenient map of your
slot assignments. If you print or copy this map, you will be able to easily
install your cartridges later.
1 On the Web client, select Reports > Library Configuration.
2 Click the Show Barcodes button.
The screen displays a map of the library showing the partitions and
the location of each cartridge, by barcode.
3 Click the print icon in the upper right corner to print the report.
Alternatively, take a screen capture of the report and save or print it,
or copy the map by hand.
Caution: Do not put your hands or any other objects into the
magazine openings while library power is on.
Top foam
Library (anti-static
wrap not shown
for clarity)
Bottom foam
Shipping carton
Top foam
Library (anti-static
wrap not shown
for clarity)
Bottom foam
Shipping carton
Bottom tray
Pallet
Scalar i80 only: Place two corner boards on the long edges on top of
the shipping carton. Strap the box to the pallet, then wrap the entire
assembly in stretch-film prior to shipping.
Caution: When unpacking the library in its new location, lift it out of
the packaging and immediately place it on its side to
remove the four thumbscrews securing the Y-tray to the
floor of the library. Do not place it upright until you have
removed the four thumbscrews, or you could damage the
chassis or the Y-tray. When placing the library on its side,
do not set it on the rack ear or the magazine handle, or
you could damage them.
This chapter covers updating library and tape drive firmware, including:
Updating Library Firmware
Updating and Autoleveling Tape Drive Firmware
About Tape Drive Firmware Autoleveling
Uploading Tape Drive Firmware Used in Autoleveling
Deleting Tape Drive Firmware Used in Autoleveling
Initiating Tape Drive Firmware Autoleveling
Caution: After the update process starts, you must wait until it
completes. Do not attempt to interrupt the process in any
way, and do not power cycle the library. Loss of data or
library operability could occur.
Web Client
1 Log into your library to view the latest firmware version available.
Click Tools > Update Library Firmware.
If you are connected to the Internet, the screen displays the
firmware currently loaded on your library and the latest available
firmware.
Note: You can also view a listing of the latest version of library
firmware on the following Web site:
http://www.quantum.com/ServiceandSupport/
SoftwareandDocumentationDownloads/SI40/Index.aspx
and click the Firmware tab.
2 Unload tape cartridges from all tape drives installed in the library.
d Go to Step 6.
f Go to Step 6.
6 Click Apply.
A confirmation dialog box displays asking you to confirm that you
want to update the library firmware and reboot the library.
7 Click OK to continue with the library firmware update operation.
The Progress Window displays. The Progress Window contains
information on the action, elapsed time, and status of the
requested operation. The Progress Window closes automatically and
the library shuts down and then reboots. You will need to log back
into the library once it has finished rebooting. Wait for the library to
completely reboot before logging back in to the library. The reboot
takes several minutes.
If Failure appears in the Progress Window, the operation failed. The
library will automatically reload the previous version of library
firmware.
8 Clear the Web browser cache before logging in to the library. See
your Web browsers documentation for instructions on how to clear
the cache.
9 Log in to the library.
If you upgrade library firmware, the baseline tape drive firmware for
that version of library firmware will overwrite the existing baseline
tape drive firmware images. If you did not previously upload a
patch, all the tape drives will be autoleveled to the new baseline. If
you previously uploaded a patch, the patch remains and tape drive
firmware will remain autoleveled to the patch. You will need to
delete the patch in order to have the tape drives autoleveled to the
new baseline (see Deleting Tape Drive Firmware Used in Autoleveling
on page 308).
If you downgrade library firmware, the baseline tape drive firmware
for that version of library firmware will overwrite the existing
baseline tape drive firmware images as well as any patches you may
have uploaded prior to the downgrade, and all tape drives will be
autoleveled to the new baseline. If you want to continue to use the
patch or a different version of tape drive firmware, you will need to
upload it again. Contact Quantum Support if you need help
obtaining firmware (see Getting More Information or Help on
page xxvii).
Autoleveling will not occur if a tape drive has a cartridge loaded in
it. Make sure to unload tape cartridges from all tape drives before
loading new firmware for autoleveling, or before upgrading library
firmware.
Autoleveling occurs after the completes its initialization. This means
it is possible for a host to see the medium changer initially, but
when the autoleveling starts on the drives it is likely the medium
changer will disappear again. Wait until autoleveling completes
before starting backup applications. (The operator panel displays a
message indicating autoleveling is taking place. Wait until this
message disappears before starting backup applications.)
If you reset factory defaults, any tape drive firmware images you
manually uploaded will be deleted (see Resetting Factory Defaults
on page 333).
Uploading Tape Drive Tape drive firmware is bundled with the library firmware and is
Firmware Used in automatically installed and autoleveled on your tape drives when you
Autoleveling install library firmware.
In some cases, a tape drive firmware upgrade or patch may be available
from Quantum Support outside of the normal library firmware release
cycle. The instructions in this section explain how to install such an
upgrade or patch.
You can also use these instructions to install down-rev tape drive
firmware. If you wish to do this, contact Quantum Support for the
firmware image files.
Caution: Only install tape drive firmware image files that have been
tested and qualified by Quantum.
You can only upload tape drive firmware on the Web client.
Web Client
1 Check the Quantum Web site to see if you are running the current
level of firmware (go to http://www.quantum.com/
ServiceandSupport/SoftwareandDocumentationDownloads/SI40/
Index.aspx and click the Firmware tab).
2 If needed, obtain the firmware download file from Quantum
Support and place it in a known location on your computer.
3 Verify with the release notes or Quantum Support that you are
installing the correct version of tape drive firmware for your library.
For support contact information, see Getting More Information or
Help on page xxvii.
Deleting Tape Drive If you installed a tape drive firmware image to override the library's
Firmware Used in baseline image used for autoleveling, you can delete it. You cannot
Autoleveling delete the library's baseline tape drive firmware images. For more
information, see About Tape Drive Firmware Autoleveling on page 305.
Note: Deleting tape drive firmware for autoleveling only deletes the
firmware and makes the library's baseline tape drive firmware
available for autoleveling. It does not initiate autoleveling or
install firmware on the tape drives. To initiate autoleveling, see
Initiating Tape Drive Firmware Autoleveling on page 310.
You can only delete tape drive firmware on the Web client.
Web Client
1 Select Tools > Drive Operations.
The Tools - Drive Operations screen displays.
2 Select Upload/remove tape drive firmware for autoleveling and
click Next.
The Tape Drive Firmware Autolevel screen displays. The screen lists
the vendor, type, interface type, form factor, and firmware revision
number for all tape drives that the library supports, whether or not
they are installed in the library.
3 Select the tape drive firmware you want to delete.
4 Click Delete.
The Progress Window displays. The Progress Window contains
information on the action, elapsed time, and status of the
requested operation. Do one of the following:
If Success appears in the Progress Window, the tape drive
firmware was successfully deleted. The librarys default baseline
tape drive firmware will now be used for autoleveling.
If Failure appears in the Progress Window, the tape drive
firmware update was not successfully deleted.
5 To initiate autoleveling, see Initiating Tape Drive Firmware
Autoleveling on page 310.
Initiating Tape Drive Autoleveling occurs automatically at specific times (whenever a tape
Firmware Autoleveling drive is added, replaced, or power cycled; when the library is rebooted;
or when you update library firmware). If you upload or remove tape
drive firmware separately from library firmware (such as a Quantum-
provided upgrade or patch) and want to autolevel the tape drives
immediately, follow these steps:
1 Unload tape cartridges from all tape drives you want to autolevel.
2 Stop all host commands to the tape drives you want to autolevel.
3 Initiate autoleveling by performing one of the following actions:
Reset (power cycle) the tape drives on which you want to
install firmware. This autolevels only the tape drives you reset. If
you reset all tape drives at once, each tape drive is reset
sequentially, causing the autoleveling to occur one tape drive at
a time. If you reset each tape drive individually, you must wait
for the autolevel to occur before proceeding to the next tape
drive. It takes about 7 minutes to autolevel each tape drive. For
instructions, see Resetting a Tape Drive on page 331.
Restart the library. This verifies and autolevels all tape drives
simultaneously. This process takes about 7 minutes for the
autolevel, plus the time it normally takes the library to reboot.
From the Web client, select Operations > System Shutdown.
Select Restart and click Apply. See Restarting the Library on
page 142 for more information.
The operator panel displays a message indicating autoleveling is
taking place. If the install or autolevel fails, you receive a diagnostic
ticket.
4 Wait until autoleveling is complete before resuming host
commands. To make sure autoleveling is complete, check the system
information report to see if the tape drive firmware is installed on all
intended tape drives. From the Web client, select Reports > System
Information.
The Scalar i40 and Scalar i80 libraries include advanced system monitoring
and alerting mechanisms that inform you of library status and issues.
The library provides you with status information about various library
subsystems and components. It also notifies you of issues it detects and
guides you through diagnosing and correcting issues before problems
interfere with backups.
This chapter covers:
About Diagnostic Tickets
Capturing Snapshots of Library Information
Troubleshooting Library Not Ready Messages
Retrieving Tape Drive Logs
Interpreting LEDs
Running the Installation and Verification Test (IVT)
Running the IVT Diagnostic Subtests Individually Robotics, Tape
Drive, and Magazine Tests
Running the Random Move Test
Performing Library Diagnostics
Resetting Factory Defaults
The library has a number of visual cues to alert you that one or more
diagnostic tickets exist:
The librarys ticket indicator LED turns on to indicate that at least
one ticket exists (see Front Panel LEDs on page 321).
The operator panel displays a health status icon (see Health status
on page 26 for description).
The Web client displays a subsystem status icon (see Subsystem
Status on page 32).
You can frequently resolve a simple problem yourself, but if the problem
is complex or involves a field replaceable unit (FRU), you will be directed
to contact Quantum Support. Only qualified service technicians can
service FRUs.
Viewing, Closing, and The initial status of all diagnostic tickets is Unopened. Once you select
Resolving Diagnostic the Resolve button, the ticket status changes to Opened. When you
Tickets close the ticket, its status changes to Closed. You can view Opened and
Unopened tickets on both the operator panel and the Web client, but
you can view Closed tickets only on the Web client.
You can view and close diagnostic tickets on both the operator panel
and the Web client, but only the Web client provides a complete
description of the event and guides you through a series of steps to
resolve the issue. It is recommended that you use the Web client to view
and resolve all your diagnostic tickets.
You can close all tickets at once but this is not recommended. It is
recommended that each diagnostic ticket be viewed, analyzed, and
closed individually.
Only one person at a time can resolve a ticket. Multiple users can,
however, view ticket details simultaneously.
If your Web client session goes down while resolving a diagnostic ticket,
you must wait 3 minutes before you can continue resolving the
diagnostic ticket.
If you do not close a diagnostic ticket and the issue recurs, the only
thing that gets updated in the ticket is the date and time the issue
recurred (listed under Last Occurrence on the Web client and Updated
on the operator panel). Ticket details are not updated because the
original issue is often the root cause. If the location of the error in the
library changed since the ticket was first issued, the ticket details will
continue to reflect the original error location.
Operator Panel
1 Select Reports > Diagnostic Tickets.
2 Select Library, Tape Drives, or Media to view tickets related to the
selected subsystem. Only the subsystems that contain tickets are
listed.
3 You can also close all tickets at once by selecting Close ALL.
4 Press Select.
All of the tickets posted for the selected subsystem are displayed.
5 Scroll through the tickets and select the one you want to view. Press
View.
Basic details about the ticket are displayed, such as ticket ID
number, short description, priority, and when the ticket was created
and updated.
6 You can either press Close to close the ticket, or press Exit to exit
without closing the ticket.
Web Client
1 You can view all diagnostic tickets by selecting Tools > All
Diagnostic Tickets. Alternatively, you can view library, tape drive,
and media tickets separately via the Home Page Subsystem Status
buttons (see Subsystem Status on page 32).
Whichever method you choose, the tickets are displayed in order of
last occurrence of each event, beginning with the most recent.
Note: You can use the Go to Diagnostic Ticket text box at the
bottom of the screen to locate a specific ticket number. In
addition, if there is more than one page of tickets, use the
Page 1 of x arrows to view the additional tickets.
5 You can also close all tickets at once by clicking the Close All Tickets
button.
Note: To display all closed tickets, select the Include Closed Tickets
check box at the bottom of the screen. The Tools - All
Diagnostic Tickets screen refreshes, with the Resolve button
unavailable for all closed diagnostic tickets.
Closing Diagnostic When you reboot the library, all currently open diagnostic tickets are
Tickets Automatically closed automatically. If any errors occur during the reboot, the library
issues new tickets.
Automatic ticket closure occurs only when you intentionally initiate a
reboot, by either restarting the library, shutting down the library, or
upgrading library firmware. Automatic ticket closure will not occur if
the library shuts down unexpectedly or if the power cord is unplugged.
Web Client
1 Select Tools > Capture Snapshot.
2 Select whether to download the file or e-mail it to a recipient, and
click Apply.
Not Ready Messages If a not ready message displays on the operator panel at startup, it
on the Operator Panel means the robot cannot move. The library may display a message
stating that it did not initialize. Try the following steps to resolve the
issue:
If the not ready message occurs upon initial installation (first time
out of the box or after a chassis replacement), make sure you
removed the Y-tray restraint as described in Chapter 2, Unpacking
the Library.
Press the Tickets button on the operator panel to view any
diagnostic tickets that occurred as a result of the error.
Log in to the Web client using the IP address that is displayed on the
operator panel screen to view ticket details and resolution steps that
may help resolve the issue.
If none of the above steps works, contact Quantum Support.
Not Ready Messages The Web client includes a header that contains the company logo,
on the Web Client product name, and the three main navigation buttons (Home, Help, and
Logout). In addition, a message in the header alerts you when the
library is not ready. (No message displays in the header when the library
is in a ready state.) For more information on Web client user interface
elements, see Web Client Layout and Functions on page 29.
Library not ready messages continue to display in the header until the
issue has been resolved, and the robot has completed its calibration.
If the library displays a not ready message, you may be able to tell
from the message how to remedy the situation. If not, the library
generates a diagnostic ticket whenever the library encounters a
problem. The diagnostic ticket may provide information that can help
you troubleshoot the problem. For more information, see About
Diagnostic Tickets on page 312. The library not ready messages
include the following, with possible solutions listed:
Message Resolution
Note: You may not see the not ready message in the Web client
until the browser refreshes. Similarly, even if the problem has
been resolved, the not ready message will not disappear
from the Web client until the browser refreshes.
Web Client
1 Select Tools > Drive Operations.
2 Select Retrieve Tape Drive Log.
3 Click Apply.
4 When the Success message displays, complete the next screens to
save the log file to your computer.
Interpreting LEDs
LEDs provide a visual indication about the status of certain library
components. LEDs can sometimes communicate that a problem exists
when diagnostic tickets cannot.
The following components of the library have LEDs:
Front panel
System control board (SCB)
Tape drives
Power supplies
Front Panel LEDs There are two LEDs on the front panel, above the power button. They
function as follows:
System Control Board The SCB has one health status LED. In addition, each Ethernet port
LEDs contains two LEDs, a green activity indicator and an amber link
indicator. The Ethernet port closest to the center of the library is for
customer use. The Ethernet port farthest from the center of the library is
for service use only.
Tape Drive/Sled LEDs The library supports SAS and Fibre Channel tape drives. The drive sled
LEDs for each are described below.
SAS
SAS Tape Drive Sleds have one LED that indicates the following:
Color Indicates
Fibre Channel
Fibre Channel tape drive sleds have two LEDs on their rear panel,
indicated on the drive sled as STATUS and LINK (see Figure 79).
Half-height
FC tape
drive
Full-height
FC tape
drive
Power Supply LED Diagnostic tickets typically report all problems related to power
supplies. You can also observe the power supply LED to see if the power
supply is functioning appropriately (see Figure 80). The power supply
LED indicates the following:
Tape Drive Test For each installed tape drive, the robot moves a
scratch tape into the tape drive, inventories the scratch tape, and
moves the scratch tape out of the tape drive. The test takes 12
minutes per tape drive.
Magazine Test Moves a scratch tape through all storage slots in
the library. These tests verify the robotics can reach all the slots in
the magazine for both get and put operations. The test takes up to
5 minutes per magazine.
Details about running the IVT include:
Running the IVT takes partitions offline and logs all users off of the
Web client.
The operator panel displays progress of all three subtests. Before a
test begins, its progress is Scheduled. When a test begins, its
progress changes to Running. Once a test completes, its progress
changes to either Passed or Failed.
You can stop the IVT by pressing the Stop button. The progress of
the currently running test changes to Stopping. Once stopped,
the current test and all other scheduled tests display Stopped.
You can only perform the IVT from the operator panel.
A scratch tape must be in the top I/E station slot. The scratch tape
must be assigned to the System partition. The scratch tape must be
compatible with all unloaded tape drives installed in the library. For
a list of supported media, see Supported Media on page 347.
Operator Panel
1 Make sure the prerequisites listed in Prerequisites for Running IVT
on page 326 are met.
2 Select Tools > IVT.
A message displays, telling you that partitions will be turned offline
and all Web client users will be logged out.
3 Press Yes to set partitions offline, log users off the Web client, and
continue with the test.
The library conducts a series of prerequisite checks to be sure
everything is in order. Each prerequisite is listed as the library checks
it. If something is not set up correctly to run the IVT, the operator
panel displays a message letting you know how to fix it. Once you
fix the issue, again select Tools > IVT. If all is in order, the test
begins.
4 When the test completes, if any of the three subtests fails, check the
library diagnostic tickets to help determine and resolve the problem.
Operator Panel
1 Make sure the prerequisites listed in Prerequisites for Running
Diagnostic Subtests on page 328 are met.
2 Select Tools > Diagnostics.
3 Select Robotics Test, Tape Drive Test, or Magazine Test and press
Select.
4 For the tape drive or magazine test, select which tape drive or
magazine you want to test, or select ALL, then press Select.
5 Press Yes to set partitions offline, log users off the Web client, and
continue with the test.
The library conducts a series of prerequisite checks to be sure
everything is in order. Each prerequisite is listed as the library checks
it. If something is not set up correctly, the operator panel displays a
message letting you know how to fix it. Once you fix the issue, start
over from Step 1. If all is in order, the test begins.
6 Once complete, if the test fails, check the library diagnostic tickets
to help determine and resolve the problem.
Operator Panel
1 Install a scratch tape in the top I/E station slot.
2 Assign the scratch tape to the System partition.
3 Select Tools > Random Move Test.
4 Press Run.
5 Press Yes to set partitions offline, log users off the Web client, and
continue with the test.
Web Client
1 Select Tools > Diagnostics.
A confirmation dialog displays, alerting you that all other users will
be logged out and library partitions will be taken offline.
2 Click OK.
You are now in a page that looks much like the regular Home page,
but with different choices in the menu bars. Also, you will notice
that all your partitions are offline.
3 Select the test you want to run from the menus. Your choices
include:
Tape Drive Reset (see Resetting a Tape Drive on page 331 for
more information)
Robotics Get/Put Test (see Robotics Get/Put Test on page 332 for
more information)
4 To exit Diagnostics, select Exit.
Resetting a Tape Drive The Drive Reset operation power cycles the tape drive while the tape
drive remains in the drive sled in the library. You may want to perform a
reset if a tape drive does not come ready or it is not behaving properly
(for example, if a tape is stuck in the drive and will not unload).
The reset may take several minutes. After the reset operation completes,
the tape drive is rebooted and reconfigured. This takes about 60
seconds. Wait 60 seconds before performing further drive operations.
You may perform a tape drive reset from either the operator panel or
the Web client. If you use the Web client, you must enter Diagnostics,
which logs out all users of the same or lower privilege level (see
Performing Library Diagnostics on page 330).
Operator Panel
1 Select Actions > Tape Drive > Reset.
2 If more than one tape drive is installed in the library, select the tape
drive you want to reset and press Reset, or select ALL.
3 Once the operation completes, the operator panel displays a
message stating that the operation completed, and there will be
diagnostic tickets if it failed.
4 Press OK.
5 Check to see if the library generated diagnostic tickets.
Web Client
1 Enter Diagnostics (Tools > Diagnostics, then click OK to take
partitions offline and log out all other users of the same or lower
privileges).
2 Select Drives > Drive Tests > Drive Reset.
3 If the tape drives are assigned to more than one partition, select the
partition in which the tape drive(s) you want to reset are located.
Select Unassigned if the tape drive(s) you want to reset are not
assigned to a partition. Click Next.
4 Select the tape drive(s) you want to reset.
5 Click Apply.
6 The test runs. When complete, a success or failure message
displays.
Robotics Get/Put Test The Get/Put Test requires the robot to remove one tape cartridge from
the top I/E station slot, and then put the tape cartridge back into the
same slot. To run this test, you must insert a tape into the librarys top
(uppermost) I/E station slot.
You can only perform this test from the Web client, by entering
Diagnostics (see Performing Library Diagnostics on page 330).
Web Client
1 Install a scratch tape in the top I/E station slot.
2 If manual cartridge assignment is enabled, assign the scratch tape
to the System partition.
3 Enter Diagnostics (Tools > Diagnostics, then click OK to take
partitions offline and log out all other users of the same or lower
privileges).
4 Select Robotics > Robotics Get/Put Test.
5 Click Apply.
6 The test runs. When complete, a success or failure message
displays.
You may want to reset factory defaults if you are completely reinstalling
or reconfiguring the library.
If you downgrade your librarys firmware version to an earlier released
version, library configuration settings will be reset to the factory
defaults for the newly installed firmware.
If you upgrade firmware, your library configuration settings remain as
you have set them.
Web Client
On the Web client, this feature is only available to service users using the
service login and password.
Operator Panel
On the operator panel, if logins are disabled (default), this operation is
available to all users. If logins are enabled, this operation is only
available to service users using the service login and password.
1 Select Tools > Reset Factory Defaults.
A message displays stating that configuration data will be cleared
and library rebooted.
2 Press Yes to continue.
This chapter describes how to work with cartridges and barcodes. When
working with tape cartridges, certain considerations should be taken
into account. For example, all tape cartridges in the library must have a
barcode label. In addition, when loading your library, you should be
aware of whether or not your cartridges are write-protected.
This section discusses these types of items in general terms. See
Supported Media on page 347 for information on what type of tape
cartridges are supported for each drive type.
This chapter covers:
Handling Tape Cartridges Properly
Write-Protecting Tape Cartridges
Supported Barcode Formats
Barcode Label Requirements
Installing Barcode Labels
The cartridge cannot have any stickers or labels attached to the top or
bottom because if the labels come loose, they can get caught in the
tape drives or become unreadable by the scanner.
Physical Specifications
Width (excluding rack ears) 17.5 in. (445 mm) 17.5 (445 mm)
Depth (from library front bezel to back 31.2 in. (793 mm) 31.2 in. (793 mm)
of library; excluding drive sleds)*
Weight (one power supply, no tape 34.9 lbs. (15.8kg) 52.4 lbs. (23.8 kg)
drives, and no tape cartridges installed)
Weight (one power supply, two tape With 2 half-height SAS tape With 2 full-height SAS tape
drives, and no tape cartridges installed) drives: 44.2 lbs. (20 kg) drives: 65.7 lbs. (29.8 kg)
* Depths listed above exclude drive sleds. Drive sleds will add up to 50 mm to the overall length of the library
depending on tape drive type (half-height, full-height, Fibre Channel, SAS). Additionally, when planning space
requirements, take into account installed cables (particularly fibre-optic cable radius on Fibre Channel tape drives).
Height (with desktop 5.3 in. (135.6 mm) 10.6 in. (268.8 mm)
feet installed)
Depth (from library front 31.2 in. (793 mm) 31.2 in. (793 mm)
bezel to back of library;
excludes drive sleds)*
* Depths listed above exclude drive sleds. Drive sleds will add up to 50 mm to the overall length of
the library depending on tape drive type (half-height, full-height, Fibre Channel, SAS). Additionally,
when planning space requirements, take into account installed cables (particularly fibre-optic cable
radius on Fibre Channel tape drives).
Capacity
Form Factor 3U 6U
Environmental Specifications
The environmental specifications of the library are listed below.
Rated AC Input Current 100 Volt 2.8 Amps 100 Volt 5.0 Amps
240 Volt 1.4 Amps 240 Volt 2.5 Amps
Communication Interfaces
Media
Vendor Generation Interface Type Speed Connector
Supported Media
Microsoft Windows
Internet Explorer (IE) 6.0, 7.0, and 8.0
Mozilla Firefox 1.0.6 or later
Linux
Firefox 1.0.6 or later
Solaris
Firefox 1.0.6 or later
Tape Alert is an open industry standard that flags errors and provides
possible solutions for storage devices and their media. This section
provides information about Tape Alert flags issued by tape drives,
including the identifying number, severity, recommended message, and
probable cause. Table 9 explains the severity codes, and Table 10 lists all
the existing Tape Alert flags and their descriptions.
Support for specific Tape Alert flags may vary based on tape drive type
and firmware revision. Not all tape drives support every Tape Alert.
Consult your tape drive SCSI manual for more information.
For more information on Tape Alert, see http://www.t10.org/index.html
for INCITS SCSI Stream Commands - 3 (SSC-3).
1 Read warning W The tape drive is having problems The drive is having
reading data. No data has been lost, severe trouble
but there has been a reduction in the reading.
performance of the tape.
2 Write warning W The tape drive is having problems The drive is having
writing data. No data has been lost, but severe trouble
there has been a reduction in the writing.
capacity of the tape.
3 Hard error W The operation has stopped because an The drive had a hard
error has occurred while reading or read or write error.
writing data which the drive cannot
correct.
5 Read failure C The tape is damaged or the drive is The drive can no
faulty. Call the tape drive supplier help longer read data
line. from the tape.
6 Write failure C The tape is from a faulty batch or the The drive can no
tape drive is faulty: longer write data to
1 Use a good tape to test the drive. the tape.
2 If the problem persists, call the tape
drive supplier help line.
7 Media life W The tape cartridge has reached the end The media has
of its calculated useful life: exceeded its
1 Copy any data you need to another specified life.
tape.
2 Discard the old tape.
8 Not data grade W The tape cartridge is not data-grade. The drive has not
Any data you write to the tape is at risk. been able to read the
Replace the cartridge with a data-grade MRS* stripes.
tape.
10 Media removal I You cannot eject the cartridge because Manual or software
prevented the tape drive is in use. Wait until the unload attempted
operation is complete before ejecting when prevent media
the cartridge. removal on.
15 Memory chip in W The memory in the tape cartridge has Memory chip failed
cartridge failed, which reduces performance. Do in cartridge.
failure not use the cartridge for further write
operations.
16 Forced eject C The operation has failed because the Manual or forced
tape cartridge was manually eject while drive
demounted while the tape drive was actively writing or
actively writing or reading. reading.
18 Tape directory W The directory on the tape cartridge has Tape drive powered
corrupted on been corrupted. File search down with tape
load performance will be degraded. The tape loaded, or
directory can be rebuilt by reading all permanent error
the data on the cartridge. prevented the tape
directory being
updated.
19 Nearing media I The tape cartridge is nearing the end of Media may have
life its calculated life. It is recommended exceeded its
that you: specified number of
1 Use another tape cartridge for your passes.
next backup.
2 Store this tape cartridge in a safe
place in case you need to restore data
from it.
21 Cleaning W The tape drive is due for routine The drive is ready for
requested cleaning: a periodic cleaning.
1 Wait for the current operation to
finish.
2 Then use a cleaning cartridge.
Check the tape drive users manual for
device-specific cleaning instructions.
23 Invalid cleaning C The last cleaning cartridge used in the Invalid cleaning
tape tape drive was an invalid type: cartridge type used.
1 Do not use this cleaning cartridge in
this drive.
2 Wait for the current operation to
finish.
3 Then use a valid cleaning cartridge.
26 Cooling fan W A tape drive cooling fan has failed. Fan failure inside
failure tape drive
mechanism or tape
drive enclosure.
30 Hardware A C The tape drive has a hardware fault: The drive has a
1 Eject the tape or magazine. hardware fault that
requires reset to
2 Reset the drive.
recover.
3 Restart the operation.
31 Hardware B C The tape drive has a hardware fault: The drive has a
1 Turn the tape drive off and then on hardware fault that
again. is not read/write
related or requires a
2 Restart the operation.
power cycle to
3 If the problem persists, call the tape recover.
drive supplier help line.
32 Primary W The tape drive has a problem with the The drive has
interface host interface: identified an
1 Check the cables and cable interface fault.
connections.
2 Restart the operation.
37 Drive voltage W The voltage supply to the tape drive is Drive voltage limits
outside the specified range. exceeded.
39 Diagnostics W The tape drive may have a hardware The drive may have a
required fault. Run extended diagnostics to hardware fault that
verify and diagnose the problem. Check may be identified by
the tape drive users manual for device- extended diagnostics
specific instructions on running (i.e., SEND
extended diagnostic tests. DIAGNOSTIC
command).
40 Obsolete
46
47 Reserved
49
50 Lost statistics W Media statistics have been lost at some Drive or library
time in the past. powered down with
tape loaded.
51 Tape directory W The tape directory on the tape cartridge Error prevented the
invalid at just unloaded has been corrupted. File tape directory being
unload search performance will be degraded. updated on unload.
The tape directory can be rebuilt by
reading all the data.
52 Tape system C The tape just unloaded could not write Write errors while
area write its system area successfully: writing the system
failure 1 Copy data to another tape cartridge. area on unload.
2 Discard the old cartridge.
53 Tape system C The tape system area could not be read Read errors while
area read successfully at load time: reading the system
failure 1 Copy data to another tape cartridge. area on load.
54 No start of data C The start of data could not be found on Tape damaged, bulk
the tape: erased, or incorrect
1 Check that you are using the correct format.
format tape.
2 Discard the tape or return the tape to
your supplier.
55 Loading or C The operation has failed because the The drive is unable to
threading media cannot be loaded and threaded: load the media and
failure 1 Remove the cartridge, inspect it as thread the tape.
specified in the product manual, and
retry the operation.
2 If the problem persists, call the tape
drive supplier help line.
56 Unrecoverable C The operation has failed because the The drive is unable to
unload failure medium cannot be unloaded: unload the medium.
1 Do not attempt to extract the tape
cartridge.
2 Call the tape driver supplier help line.
57 Automation C The tape drive has a problem with the The drive has
interface failure automation interface: identified an
1 Check the power to the automation interface fault.
system.
2 Check the cables and cable
connections.
3 Call the supplier help line if problem
persists.
58 Microcode W The tape drive has reset itself due to a Microcode bug.
failure detected microcode fault. If problem
persists, call the supplier help line.
61 Reserved
64
* Media Recognition System (MRS) is a method where pre-defined stripes are placed at the beginning of the media
to identify the media. The MRS stripes are read to determine if the media is of data-grade. Data-grade media
should be used in SCSI streaming devices since it is of the required quality and consistency to be used to store data
(i.e., audio/video grade media should not be used).
Numerals 1U, 2U, 3U, etc. Racks manufactured for mounting computer
hardware often define vertical space as units. The
components that are mounted in the racks are defined by how
many units of rack space they require. For example, the height
of a unit in a rack is 1.75 inches. If a component is 5.25 inches in
thickness, the component is said to be a 3U component.
B Barcode A printed array of varied rectangular bars and spaces that can
be scanned and read for object identification.
Bus A transmission channel through which electrical signals are
carried from one device to another device.
K Kernel The heart of the UNIX operating system. The kernel is the part
of the operating system that allocates resources and controls
processes. The design strategy has been to keep the kernel as
small as possible and to put the rest of the UNIX functionality
into separately compiled and executed programs.
L L_Port Loop Port. It only has the capability to communicate over FC-AL
hubs and through FL_Ports.
LED (Light Emitting Diode) The mode of data transmission for
multimode cables with short wave optical transceivers. Single-
mode cables, by comparison, use high powered, long wave
lasers.
Library A large-scale tape device with robotics that can house multiple
tape drives and a significant amount of tape cartridges.
Library Control Module See Control module.
License key An absolute value that can only increase a licensed
feature. For example, a license key can be applied to the library
to enable unlicensed slots.
Logical library See Partition.
Loop With this Fibre Channel option, the port operates with attached
loop-capable devices. If a point-to-point device is attached, the
appliance is not able to communicate with it.
Loop ID A unique 7-bit value from 0 to 126 that represents the 127
valid AL_PAs (physical addresses) on a loop.
LTO (Linear Tape Open) A family of magnetic tape media that are
open in the sense of not being owned by a single proprietor.
LTO comes in two formats, Accelis and Ultrium. Accelis is the
fast access implementation, while Ultrium is the high capacity
implementation.
LUN (Logical Unit Number) A unique identifier used on a SCSI bus to
distinguish between devices that share the same bus. A LUN can
be an end user, a file, or an application. In storage technology, a
single large storage device might be divided into smaller pieces,
either to make the vast storage space more manageable or
because the storage space is dedicated to different servers,
drives, or applications. When the storage space is divided into
smaller parts, each part is configured with its own SCSI unique
identifier, or LUN.
T Tape drive A device that spins disks and tapes while it reads and writes
data in storage.
TCP/IP (Transmission Control Protocol/Internet Protocol) The
communications protocol used by the Internet. It runs on top of
Ethernet to provide high-level networking services to
applications.
Topology The logical and/or physical arrangement of stations on a
network.
Trap An SNMP alert that is sent when predefined conditions are met.
For example, an error trap tests for an error condition and
provides a recovery routine.
U
User ID An alphanumeric value that the password database associates
with a login name. Also, UID.
UTC (Coordinated Universal Time) The world-wide standard for time,
commonly considered to be the equivalent of Greenwich Mean
Time and Zulu time. For all of these time standards, zero (0)
hours is midnight in Greenwich England, which lies on the zero
longitudinal meridian. The sequence of the letters in the
acronym is a compromise between the English and French terms
(Temps Universel Coordonn).
installing 179
T Quantum-supplied 188
Tape Alerts 349 user-supplied 189