This page describes the local control station on a Sulzer RTA96C 12 cylinder engine as fitted to the latest generation of
container ships.
The instructions at the local control panel are reproduced below. Local Control Panel. The Governor speed setting dial is the black
knob above the telegraph.
MANOEUVRING INSTRUCTIONS
1 of 4 06-02-2017 22:42
Sulzer RTA 96C local control station http://www.marinediesels.co.uk/members/starting_&_reversing/sulzer_lo...
STARTING STARTING
STOPPING STOPPING
REDUCE LOCAL CONTROL SPEED SETTING MOVE FUEL CONTROL LEVER TO ZERO
MOVE STOP LEVER TO STOP POSITION MOVE STOP LEVER TO STOP POSITION
FOR AUXILIARY BLOWERS CUT OFF MOVE FOR AUXILIARY BLOWERS CUT OFF MOVE
THE REVERSING LEVER TO RC POSITION THE REVERSING LEVER TO RC POSITION
ADJUST THE LOCAL CONTROL SPEED QUICKLY BRING THE FUEL CONTROL LEVER
SETTING TO THE SAME LEVEL AS INTO THE SAME POSITION AS THE FUEL
INDICATED BY TACHOMETER LINKAGE AND LINK THEM TOGETHER
CHECK THE ENGINE SPEED
MOVE THE MANOEUVRING LEVER TO RUN
AHEAD OR RUN ASTERN (THE SAME
ROTATIONAL DIRECTION IN WHICH THE C) EMERGENCY CONTROL
ENGINE IS RUNNING) (RUNNING WITH FUEL CONTROL PUSH
BUTTONS)
There are three levers on the local control station; A MANOEUVRING lever which is normally in the REMOTE
CONTROL position, a RUN-STOP lever which is normally in the RUN position and a FUEL CONTROL lever which is
normally in the REMOTE CONTROL position.
The MANOEUVRING lever and the RUN-STOP lever are connected by rods which control the starting pneumatic
2 of 4 06-02-2017 22:42
Sulzer RTA 96C local control station http://www.marinediesels.co.uk/members/starting_&_reversing/sulzer_lo...
The local control can operate under two different conditions; with or without the governor. If the governor is operational
then all that needs to be done to change over whilst running is to match the speed setting control on the control panel with
the speed of the engine and then move the MANOEUVRING lever into the appropriate run position (ahead or astern).
If changing over to local control because the governor is faulty, then the FUEL CONTROL lever must be connected to the
fuel linkage.
This is achieved by moving the FUEL CONTROL lever out of its remote control position and locating the spring loaded
pin in the hole in the fuel control linkage shown on in the photo above. The fuel is controlled by winding the handwheel
on the FUEL CONTROL lever which moves the control rod to the fuel pump shaft