Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Atr SPLL (Max) El DWG VT (l6 l16) 1300

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES

25 24 22 20 19 1. ALL DIMENSIONS ARE IN mm

REFERENCE DRAWINGS
REV. REV.
DESIGN DRAWING NO SHOP DRAWING NO
NO NO
8355 9820 7050 5575 ATR-DT3-AR-DWG- 3002 R3
CKR-2540-VT-PL-102-00 R1
ATR-DT3-AR-DWG- 3002 R3
SEC SEC
ATR-DT3-AR-DWG- 3502 R0
Y W
ATR-DT3-AR-DWG-3503 R0
ATR-DT3-AR-DWG-3503-01 R0
ATR-DT3-AR-DWG-3503-02 R0
ATR-DT3-AR-DWG-3504 R0
DETAIL -01

TOTO
CWT822J(T1)

TOTO
CWT822J

10000
TOTO
CWT822J(T1)

TOTO
CWT822J

LT240C
TOTO
LT240C
TOTO
REF

CWT822J(T1)
CWT822J
TOTO

TOTO
TOTO
CWT822J(T1)

DETAIL -02 WM

DW
WH
SEC SEC
TOTO
CWT822J

Z Z

REF
TOTO
PAY1780E

WM
LPG WH
PROJECT
E COLOMBO RESIDENTIAL TOWER

1675
COLOMBO, SRI LANKA
VOID
F CLIENT
2%

INDOCEAN DEVELOPERS (PVT) LIMITED

2600
DN

EXTRACT DUCT
ELEV B4 ELEV B5 ELEV B6 ELEV B7 DESIGN ARCHITECT
SAFDIE ARCHITECTS, LLC.
100 PROPERZIE WAY
G SOMERVILLE, MA 02143-3740 USA
T 617.629.2100 F 617.629.2406
UP
ASSOCIATE ARCHITECT

2750

31600
DESIGN TEAM 3
SINGAPORE
DN T 658.499.7168
STRUCTURAL ENGINEER
H MR. PREDRAG EROR
P.O. BOX 102803, DUBAI, UAE
ELEV B2 ELEV B3 T 9714.3629234 F 9174.3629234

13

14

15

16
12

17

18

19
20
11
DN

2900
10
MECH, ELECT, PLUMBING ENGINEER
ELEV B1
2%

CKR CONSULTING ENGINEERS PVT. LTD.


09

08

07

06

05

04

03

02

01
PO BOX 73889
DUBAI, UAE
J T +97143384277
LANDSCAPE ARCHITECT
DETAIL -02

1675
VOID P LANDSCALE CO., LTD.
59/3 SOI SUKHUMVIT 39 SUKHUMVIT ROAD, KLONGTON NUA
K WATTANA, BANGKOK 10110 T. 662.261.3700.9
LOCAL STRUCTURAL ENGINEER & SUPERVISION CONSULTANT
REF

WM DEEPAL WICKREMASINGHE ASSOCIATES


WH
NO. 377/2, Thalawathugoda Road, Hokandara South, Sri Lanka.

CWT822J(T1)
TOTO
SEC WM SEC T- +94 11 4402395
DW

WH
X X
ISSUE
W12 NO. DESCRIPTION DATE
DW

00 FOR APPROVAL 10.06.2016


01
02
03

10000
04
05
CO-0RDINATION CERTIFICATE
S. NO DISCIPLINE DATE SIGNATURE
1.
2.
3.
4.
KEY PLAN
L
DETAIL -01 H F D B

G E C A
SEC SEC
Y W ALTAIR
Indocean Developers (Pvt) Ltd Main Contractor
21
No: 121A, Sir James Peiris Mawatha
25 24 22 20 19
21 20 19 Colombo 02
Approved
Approved as Corrected
FIN.CEILING = L+2550MM
Submit Specified Item
FIN.CEILING = L+2 550
FIN.CEILING = L+2400MM
CUBICLE TOP
FIN.CEILING = L+2 400
CUBICLE TOP
FIN.CEILING = L+2 400 FIN.CEILING = L+2400MM
FIN.CEILING = L+2 400
Revise and Resubmit
Rejected Sub Contractor
MAXAIRE (PVT) LTD
110 , Isipathana Mawatha,
Colombo 05.
The review is only for general conformance T : +94 11 2501370, 2501305, 4641477
with the design concept of the project and F : +094 11 2589860
general compliance with the information given E : info@maxaire.net

in the Contract Documents. Contractor is


responsible for: Dimensions to be confirmed DISCIPLINE ELECTRICAL
and correlated at the job site; information that
SECTION- X X TYPICAL DETAIL- 01 pertains solely to the fabrication processes or
SCALE: 1:100
SCALE: 1:100 to the means, methods, techniques, DRAWING TITLE
sequences, and the procedures of VERTICAL TOWER LEVEL
19 20 22 24 25 constructions; coordination of the Work of all
trades; and for performing all work in a safe ( EVEN NUMBERS ) 6 - 16
25
and satisfactory manner. POWER CONDUIT LAYOUT
Any approval from the Engineer/Consultant of
FIN.CEILING = L+2550MM
submittals, materials and workmanship etc. Detailed Drawn Checked Approved Scale Size
shall not relieve the Contractor of his sole
responsibility and obligation to comply with 1:100
all requirements under the Contract.
Udayashantha Hirushan Fazal Premasiri A1
Consultant/Engineer
Date Date Date Date
10.06.2016 10.06.2016 10.06.2016 10.06.2016
Reviewer Drawing Number Rev.
SECTION - Z Z TYPICAL DETAIL- 02 ATR-SPLL(MAX)-EL-DWG-VT-(L6-L16)-1300
SCALE: 1:100 SCALE: 1:100 Signature Date 0
Status
SHOP DRAWING

You might also like