Read Me
Read Me
Read Me
ReadMe.rtf
Note
This Product Information contains important information about DIGSI 4.83.
It is part of the product supplied, and the information in it should be
considered more up-to-date than any other information if uncertainties arise.
2 Hardware Requirements
3 Software Requirements
4 Installation
5 Release Notes
7 Hotline
DIGSI 4 ReadMe.rtf
Edition 10/2009 3
DIGSI 4
Dear customer,
• With the SIGRA evaluation program you can visualize and exactly evaluate
fault records.
• The graphic display on the larger displays can be designed and edited with the
Display Editor as with a graphics program; templates are provided on the CD-
ROM for further processing.
• You can configure additional functions of the devices graphically with the CFC
Editor.
• You can conveniently set remote communication with DIGSI Remote. An
electronic telephone book is available, for example for communication by a
modem line.
• What is new since DIGSI 4.60 is the IEC61850 System Configurator enabling
you to configure and parameterize IEC61850 stations. This tool allows you to
manage subnets, network communicators and their IP addresses and to
connect the information items of different communicators.
To install them you must enter the serial number provided on the product card; then
you can initialize the components you ordered. Please keep the product card with
the serial number in a safe place.
As an alternative, you can enter "Trial" to use DIGSI together with all option
packages for up to 30 days for free.
Installation notes
The installation notes contain important information that you require to install DIGSI
4.83. Read these notes before installing the software.
DIGSI 4 ReadMe.rtf
Edition 10/2009 5
2 Hardware Requirements
To work with DIGSI 4.83, you require a PC or laptop with the following minimum
specifications as regards processor performance, RAM main memory and
graphics:
If you are dealing with comprehensive projects with several dozens of protection
devices, for example, you should use a PC meeting the latest standards of
performance.
Startup Environment
Operating Systems
DIGSI 4.83 is a 32-bit application whose functionality has been especially been
designed for the following operating systems:
• MS Windows XP Professional SP 3
• MS Windows Vista 32-Bit Home Premium, Business, Enterprise and Ultimate
with SP1
• MS Windows Server 2003 Standard Edition with SP2 as Workstation computer
DIGSI 4.83 has not been tested for the following operating systems; use at your
own risks:
• MS Windows XP Professional without any service pack
• MS Windows 2000
• MS Windows Server 2003, SP1, SP1 R2
• MS Windows Server 2008
DIGSI 4 ReadMe.rtf
Edition 10/2009 7
Virtual environment
DIGSI 4 now also supports the virtual environment VMWare (for more information,
see www.vmware.com).
The features of the VM comply with the following operating systems:
• MS Windows XP Professional SP 3
• MS Windows Vista 32-Bit Ultimate and Business with SP1
The performance of DIGSI 4.83 is not ensured in a virtual machine running under
other operating systems for which DIGSI 4 has been approved; use at your own
risks:
Memory Requirements
TOOLBOX II
The usage of DIGSI 4.83 and TOOLBOX II V4.10 SP1 on one system is possible.
Spectrum Power CC
The usage of DIGSI 4.83 and Spectrum Power CC IMM V4.20 on one system is
possible.
Rational ClearCase
DIGSI 4.83 projects must not be stored on ClearCase drives; that is, drives that are
linked to a ClearCase View (MVFS).
DIGSI 4 ReadMe.rtf
Edition 10/2009 9
However, device files processed with DIGSI 4.83 cannot be processed with an
older DIGSI version.
4 Installation
If you are using Windows Vista, we recommend to not install DIGSI into the root
directory of a drive.
If you are using Windows Vista and the full version of Step7 V5.4, we recommend
to install DIGSI into the directory suggested during installation.
If you are using Windows Vista with a Chinese language option, we recommend to
install DIGSI into the directory suggested during installation (if necessary on
another drive).
You cannot install DIGSI 4.83 over an existing DIGSI 4 installation. In this case, the
old DIGSI 4 version must first be deinstalled using the deinstallation program (see
below). Important: Following deinstallation, the computer must always be rebooted!
For optimum display of the information during setup, you should set the colors in
the control panel of your computer to at least 65536 colors.
Before starting the setup program, please close all applications (such as MS Word,
etc.) and the control panel window, since you have to restart your computer
following the DIGSI installation so that all the system variables can be entered
completely.
Note
If you want to use STEP7 and/or SICAM on the target computer, you have to install
these software packages before installing DIGSI.
Insert the DIGSI 4 DVD called "Program and Device Drivers" in the drive. The
DIGSI setup program will guide you through the installation. The installation
program starts automatically after inserting the DIGSI 4 DVD. If you have disabled
this function on your computer, start the setup program with the MS Windows
Explorer by double-clicking on the SETUP.EXE in the root directory.
If you want to change the default installation path of the DIGSI 4 setup, make sure
that you do not install directly to the root directory (e.g. D:) of your computer. You
should maintain at least one subdirectory such as "DIGSI4", D:\DIGSI4, for
example.
The installation of the selected components starts.
Some notes on what is required during setup:
• You can select any drive you want to install DIGSI 4 on. Sufficient hard-disk
space (see chapter memory requirements) must be available.
• Do not install DIGSI 4 in a directory whose path contains non-ASCII characters
(see chapter "Notes on the usage of foreign language character sets").
DIGSI 4 ReadMe.rtf
Edition 10/2009 11
B. Releasing DIGSI 4 exclusively for DIGSI users
3. Create a user group named "DIGSI4 Users".
4.3 De-Installation
With the Windows uninstaller you can remove DIGSI 4 with all optional
components from your PC. During the de-installation you remove all data installed
by the installation program of DIGSI 4. The user-specific data like projects remain
unaffected.
5.3 Internet
To also always be up to date in the future, please use the offer at our download
web site in the Internet at the address
http://www.siemens.de/energy/siprotec (in German),
http://www.siemens.com/energy/siprotec (in English).
DIGSI 4 ReadMe.rtf
Edition 10/2009 13
6 New features and Changes Compared to
Earlier Versions
General Information
1. The product now supports Windows XP SP 3.
DIGSI 4 ReadMe.rtf
Edition 10/2009 15
and offering it in a simply manageable file for
configuration tools of other manufacturers. An import
of ICD files is not provided by DIGSI and is not
needed.
6.2 Fault corrections
The following fault was eliminated:
ERR_36253
A parallel use of static and dynamic reports in the IEC 61850 was not possible in DIGSI 4.82
without manual corrections. A newly established parameter in the system configurator
permits the choice whether dynamic reports are also needed or whether an automatic
optimization using purely static reports can take place.
ERR_37804
At the online change of settings, DIGSI 4 has an extended mechanism. This mechanism
recognizes now also for special cases the differences to the offline data storage and offers a
synchronization.
ERR_37151
The USB/RS232 converter is recommended for the connection of the SIPROTEC 4 devices to
PCs without a serial interface. It does not work under MS Windows Vista.
ERR_36329
After upgrading the device driver of a SIPROTEC 4 device and adding an EN100
communication module later, the IED name of the device was empty and not alterable. The
IED name of the SIPROTEC 4 device remains unchanged after the upgrade now and is
furthermore alterable.
ERR_35283
An improved version of the Russian online help of the CFC blocks is available now.
ERR_37997
In some situations, the maximum number of cycle counters supported by the SIPROTEC device
could not be used. It is possible now to use all available cycle counters.
ERR_38848
Problems occurred in the interplay with USB drivers of other manufacturers. These problems
prevented a communication with the SIPROTEC devices connected over USB cables. A
stable connection is possible now, if USB drivers of other manufacturers exist.
ERR_36367
A fault prevented the correct operation of "Check switching authority at Remote commands” on
IEC 61850 systems. The execution of this function is possible now without problems.
DIGSI 4 ReadMe.rtf
Edition 10/2009 17
ERR_37259
The behavior of the system while changing the online and offline parameter set at the same
time has been improved.
ERR_36175
The compatibility during the import of ICD and SCD files of other manufacturers has been
improved.
ERR_39856
The performance during the creation of reports in the System configurator (IEC 61850) has
been improved significantly.
ERR 35264
The sporadic system failures during settings block comparison have been corrected.
ERR_35350
It is now possible to add user-defined information to newly created groups in the Excel Addln.
ERR_35608
From now on, you can also install DIGSI 4 on the operating system variants MS Windows Vista
Enterprise and Home Premium.
ERR35640
From now on, you can use the front or rear interface of the 7SS522 central unit without
restrictions to communicate between the central unit and the bay units 7SS523/7SS525
under DIGSI 4.
ERR_39448
System visualization of the 7SS522 central unit now also displays the current measured values
of the check zone.
6.3 Known Problems
1. ERR_36367: The check box “remote commands (system interface DIGSI)“ is
without function.
Situation:
Up from EN100 module firmware version V4.0 the check box “remote
commands (system interface DIGSI)“ is without function. Regardless of whether
the check box is activated or deactivated the function “remote commands” is
always active in the device.
Caution:
In DIGSI V4.83 the check box “remote commands (system interface DIGSI)“ is
disabled for the user. The check box may be activated or deactivated which
depends on its previous usage, but this has no effect on the by default activated
function of remote commands in the device (up from EN100 V4.0).
Situation:
You can change the operating language of the DIGSI 4 Manager any time.
Caution:
If the operating language is changed, the standard device texts in the edge bars
of a CFC chart remain in the language originally set. You can only obtain these
texts in the desired language when you delete and then restore every
connection to the edge bar.
Situation:
It is possible to operate a device via the front or the rear interface. Even for bus
users (PROFIBUS FMS, ETHERNET), concurrent access by several users is
possible.
Caution:
Situation:
Devices are managed in the DIGSI 4 Manager. They can be selected from the
DIGSI 4 ReadMe.rtf
Edition 10/2009 19
device catalogue and inserted in a project.
Caution:
When inserting a device with a large range of functions (e.g. 7SJ63...), the
message "Server is at full capacity" may appear. This message is meaningless:
The device will still be inserted correctly.
5. Hierarchical CFC Charts Cannot Be Used
Situation:
With the new version, the ability to save modules and their circuitry in a new
macro module (hierarchical charts) is offered in the CFC option package.
Caution:
Situation:
You have installed and started the new version, and now you want to open a
project edited previously.
Caution:
Projects which have just been created, are initially not visible.
Select "Open" and then the button "Search..." .
In the next dialogue you mark the desired projects and confirm them with "OK".
Situation:
The DIGSI 4 Manager then no longer reacts, as the modem connection is not
re-established. Close the so-called ComTask (icon in system area of the
Windows taskbar).
Situation:
DIGSI 4 ReadMe.rtf
Edition 10/2009 21
9. No PROFIBUS-FMS connections
Situation:
Situation:
Although it appears to the user that configurations are identical, differences may
be displayed when con-figuring user-defined information during the comparison.
Caution:
The reason for this is that this information has been inserted in the matrix in a
different order.
Situation:
Copy the user-defined libraries directly in the file system using the MS Explorer.
User-defined dynamic icons are located in the directory
...Digsi4\SSLib\SSData\dyndin
User-defined static icons are located in the directory
...Digsi4\SSLib\SSData\stauser.
12. Incomprehensible error messages for modem communication (No.438)
Situation:
0x80000005
The call could not be executed due to a busy line or a missing dialing tone, for
example.
0x80000048
0x8000004B
If this error occurs while initializing a modem, you have to send a reset
command (AT&F or ATZ, depending on the modem type) to the modem. This
error may also occur if the interface is busy while attempting to initialize a
modem.
0x80000022
An invalid character was entered in the phone book: For example, a letter or an
invalid country code.
13. No measured value update for PROFIBUS FMS (No.391, 10566, 10614,
13052)
Situation:
If windows for measured values are open for a longer time (1 hour) the values
may not be updated. DIGSI device editor may crash. This error applies for
PROFIBUS FMS connections only.
Caution:
If DIGSI crashes, you have to close the task in the task line.
DIGSI 4 ReadMe.rtf
Edition 10/2009 23
14. Upgrading a SIPTROTEC device to IEC61850 (No.1877)
Situation:
Situation:
Situation:
If the DIGSI Device Editor was opened at least once before archiving a DIGSI
project, you have to close and re-open DIGSI Manager in order to archive the
project.
17. After a device upgrade timer blocks in the CFC charts must be deleted and re-
inserted (No. 26598)
Situation:
After a device upgrade to a higher version (e.g. V4.50 => V4.62) and
subsequent compilation of the CFC charts, for "old" devices (<=V4.50), an error
message will be displayed saying that the timer blocks are in the wrong task
level.
Solution:
After a device upgrade, replace all timer blocks in the CFC charts with new
timer blocks from the catalog. Then update all blocks (Options => Block types)
and compile the CFC charts.
18. Unnecessary transfer of parameter set during online connection (No. 23060)
Situation:
Situation:
Situation:
When assigning switching cycle counters to commands, you may receive the
message that the limit has been reached.
Caution:
To cancel existing assignments, you should select "Others" in the "Switch type"
field for the corresponding command under the IEC61850 properties. You can
now make additional assignments.
Situation:
The data transmission stop does not work for a SIPROTEC V4 device
(IEC60870-5-103). Although the transmission stop is activated, messages and
measured values are still being transmitted.
Solution:
Open your device in DIGSI and check whether the data transmission stop
(DataStop) is routed to the sys-tem interface as the destination in the
configuration matrix..
DIGSI 4 ReadMe.rtf
Edition 10/2009 25
22. DIGSI not offered in the start menu under Vista (No. 34335)
Situation:
Under MS Vista, the entry "Siemens Energy" can not be opened directly in the
Windows start menu when using a Chinese operating system.
Solution:
Situation:
After Import of XML-file created by DIGSI for "T103 Redundant" the commands
are missing.
In this file DIGSI uses the XML Attribute "DUType", but PAS is expecting
"DUTyp" during import..
Solution:
7 Hotline
If you have problems with DIGSI, contact our Customer Support Centre.
eMail: support.energy@siemens.com
FAQ: http://www.siemens.com/energy-support