Venue SC48
Venue SC48
Venue SC48
003, 96 I/O, 96i I/O, 192 Digital I/O, 192 I/O, 888|24 I/O, 882|20 I/O,
1622 I/O, 24-Bit ADAT Bridge I/O, AudioSuite, Avid, Avid DNA, Avid Mojo,
Avid Unity, Avid Unity ISIS, Avid Xpress, AVoption, Axiom, Beat Detective,
Bomb Factory, Bruno, C|24, Command|8, Control|24, D-Command, D-Control,
D-Fi, D-fx, D-Show, D-Verb, DAE, Digi 002, DigiBase, DigiDelivery, Digidesign,
Digidesign Audio Engine, Digidesign Intelligent Noise Reduction, Digidesign
TDM Bus, DigiDrive, DigiRack, DigiTest, DigiTranslator, DINR, D-Show,
DV Toolkit, EditPack, Eleven, HD Core, HD Process, Hybrid, Impact, Interplay,
LoFi, M-Audio, MachineControl, Maxim, Mbox, MediaComposer, MIDI I/O, MIX,
MultiShell, Nitris, OMF, OMF Interchange, PRE, ProControl, Pro Tools M-Powered,
Pro Tools, Pro Tools|HD, Pro Tools LE, QuickPunch, Recti-Fi, Reel Tape, Reso,
Reverb One, ReVibe, RTAS, Sibelius, Smack!, SoundReplacer, Sound
Designer II, Strike, Structure, SYNC HD, SYNC I/O, Synchronic, TL Aggro,
TL AutoPan, TL Drum Rehab, TL Everyphase, TL Fauxlder, TL In Tune,
TL MasterMeter, TL Metro, TL Space, TL Utilities, Transfuser, Trillium Lane Labs,
Vari-Fi Velvet, X-Form, and XMON are trademarks or registered trademarks of Avid
Technology, Inc. Xpand! is Registered in the U.S. Patent and Trademark Office.
All other trademarks are the property of their respective owners.
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
FOH Rack Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Included Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Expansion Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operational Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FOH Rack Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FOH Rack Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FOH Link Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Contents iii
iv FOH Rack
Chapter 1: Introduction
The VENUE FOH Rack is an expandable rack component that CPU, DSP, and System Drives
provides, in conjunction with a Stage Rack for remote stage
connections, local I/O, computer, and DSP processing for The FOH Rack houses the CPU, DSP, hard drive and CD-ROM
VENUE D-Show systems and VENUE Profile systems. drive that run the VENUE software on your VENUE system.
VENUE software is installed at the factory. The CD-ROM drive
lets you update or restore your VENUE system software, and
install compatible plug-ins from their installer discs.
FOH Rack Features
A standard FOH Rack includes three Mix Engine cards, which
Audio I/O provide DSP for plug-ins and mixing. You can add two op-
tional Mix Engine cards, up to a maximum of five.
8 pairs of analog I/O for hardware inserts, or for input
and output of line-level program material from the FOH
Redundant Power Supply Units (PSUs)
position.
Analog and Digital (AES or S/PDIF) 2-Track inputs and Each FOH Rack comes with dual redundant, field replaceable
outputs. (100V to 240V nominal, 5060 Hz) PSUs with auto redundant
Com mic input, with gain control and phantom power. failover and LED status indication.
Monitor outputs to connect to near field monitor speak-
ers at the mix position.
Included Components
Synchronization and Control I/O
The following components are included in a standard
MIDI In and Out ports, providing 16 channels of MIDI FOH Rack configuration:
input and 16 channels of MIDI output.
1 FOH Rack unit
Word clock I/O for digital clock synchronization.
1 FOH Link cable (for connection to a VENUE D-Show
USB 2.0 ports for USB disks, iLoks, and other USB devices.
Main/Sidecar or a VENUE Profile console)
100 BaseT Ethernet (ECx) port for Ethernet-based remote
control. 2 IEC power cables
Chapter 1: Introduction 1
Expansion Options Operational Requirements
2 FOH Rack
FOH Rack Front Panel
USB port
FOH Link
connector
Power Reset
switch buttons
Reset Buttons
CD-ROM Drive
Pressing both Reset buttons simultaneously instigates a full
system restart. The built-in CD-ROM drive is for installing software updates,
plug-ins, and other data. The CD-ROM drive is read-only. No
Use the Reset buttons only in the event of an emergency. data can be written to blank discs placed in the drive.
Chapter 1: Introduction 3
FOH Rack Back Panel
IO section
ECx port
Snake
Expansion input and
section output section
Hard
drive
bay
AC power
connectors
USB port and power
supplies
ECX Port Active LED Green LED lights to indicate that connection to
FOH Rack is active for the corresponding Snake. Only one
Use the ECx port to connect a laptop, tablet, or a wireless Snake can be active at a time.
router to the FOH Rack to control your VENUE system re-
motely, enabled by ECx Ethernet Control host and client soft- Sig LED Green LED lights to indicate that signal is present on
ware. (This port does not support networking or any commu- the corresponding Snake.
nication other than ECx.)
All Snake LEDs flash when no Snake signal is present.
To use ECx, you must first install the host and client software
applications. See the VENUE D-Show Guide or the VENUE
Power Supply
Profile Guide for more information on installing and using
ECx. The FOH Rack contains two power supplies. The redundant
power supply automatically takes over in the event of a loss of
Snake Input and Output Section power to, or failure of, the primary power supply.
4 FOH Rack
I/O Section
Chapter 1: Introduction 5
FOH Link Cable
TB Bundle HP Bundle
+ Foil Shield + Foil Shield
Rack Bundle
Overall Shield + Foil Shield
+Foil/Braid Shield
USB Bundle
+Foil Shield VGA Bundle
+ Foil Shield
CAN Bundle
+ Foil Shield Drain Wire
Cable Specifications
VGA Bundle:
3 x 75 Ohm Coax, 2 x 24 awg Pair, 3 x 28awg
+ Foil and Braid shield
USB Bundle:
1 x 28 awg Pair, 4 x 24awg + Drain
+ Foil and Braid shield
Rack Bundle:
5 x 28 awg, Foil shield
6 FOH Rack
Connector Pinouts FOH Link cable CAN BUNDLE pinouts
P1 CAN BUNDLE P2
FOH Link cable VGA BUNDLE pinouts
V ID V a CAN 3 H a
W GND W D CAN CS D
p HSYNC p K USB 5+ K
d USB D d
FOH Link cable RACK BUNDLE pinouts
G USB SHIELD G
P1 RACK BUNDLE P2
f USB +5 f
HH RACK PSU HH
c USB GND c
BB RACK GND BB
DD SPR 1 DD
GG SPR 2 GG
R TB P R
j TB N j
y TB GND y
P TB SHEILD P
P1 HP BUNDLE P2
N HP L N
i HP R i
h HP GND h
M HP SHEILD M
Chapter 1: Introduction 7
8 FOH Rack
Chapter 2: Connecting the FOH Rack
Figure 5. FOH Link connection between Profile (left) and FOH Rack (right)
the FOH Link cable to the FOH Link port on the front panel of the FOH Rack. On each end, be sure to align the notch in the con-
nector housing with the slot in the plug, and to rotate the collar until the connector is fully latched.
Figure 6. FOH Link connection between D-Show Main unit (left) and FOH Rack (right)
2 Connect the return snake to the Stage 1 Out Port of the FOH Rack to the Stage 1 In port on the Stage Rack.
The connectors on Avids Digital Snake cable are color coded, so that the white connector connects to the white-outlined ports on
the Stage Rack and the FOH Rack.
3 If you are using a second redundant snake, connect it to the Snake 2 ports on each unit in the same manner.
If you are using a second redundant snake, the primary and the redundant snake must be the same length.
When the FOH Rack and the Stage Rack are powered up, the primary snake connection is indicated by the solid Active LED
(marked Active). If the Snake Signal LEDs flash, a Snake connection has not been established.
If there are problems with the Digital Snake connection, double check that all the BNC connectors are fully secured. If the
problem persists, try reversing the connectors connected to the In and Out ports on one end.
Redundant Snake
connects here
Redundant Snake
connects here
Figure 7. Detail of Digital Snake cable connection between Stage Rack (left) and FOH Rack (right)
If a second Stage Rack is used, an additional Snake Card must be installed in the FOH Rack. See the Snake Card Guide
for more information.
10 FOH Rack
Ancillary Connections Powering the System Up and Down
(AC Power, Synchronization and Optional Connections) Powering Up
AC Power Connectors Faders move when power is turned on. Before powering up the
system, make sure all fader paths are clear of obstructions.
The AC Power connectors accept standard AC power cable, for
powering each of the two redundant power supply units. FOH Power up the system in the following sequence:
Rack power supplies are auto-power selecting (100V to 240V, 1 VENUE console
5060Hz) and automatically work with a standard modular
power cord when connected to an AC receptacle in any coun- 2 FOH Rack
try.
Each unit has a separate power switch.
The power supplies in FOH Rack have their own power
3 Stage Rack
switches. These must be in the On position in order to power
up the FOH Rack via the front panel power switch. 4 Any connected computers for recording/playback options
See the VENUE D-Show Guide or the VENUE Profile Guide 1 Audio monitoring system
for more information on ECx. 2 Any connected computers for recording/playback options
3 FOH Rack
USB Ports
4 Stage Rack
The USB ports on the front and back panel of the FOH Rack let
you connect iLoks, USB key disks and other USB devices. (An 5 VENUE console
additional, secure USB port is located inside the FOH Rack
chassis as well; use this internal port to connect and secure a
pre-loaded iLok to always be available to that FOH Rack sys-
tem.)
Restarting the System
If at any time during setup or performance it becomes neces-
sary to restart the system, you can restart the entire system or
Word Clock I/O
reset individual hardware devices.
The Word Clock In Out ports transmit and receive word clock
signals, letting you integrate external digital devices with For more information on restarting your VENUE system
FOH Rack. The ports are also used to integrate a second Snake and resetting system hardware, see the Troubleshooting
card into your system. chapter of the guide that came with your console (VENUE
Profile Guide, or VENUE D-Show Guide).
For more information on using FOH Rack word clock I/O,
see the guide that came with your console. See the Snake
Card guide for more information on setting up a second How to Proceed
Stage Rack.
To learn how to operate your VENUE system, see the
VENUE Profile Guide or VENUE D-Show Guide that came with
your console.
Rack Spaces 10 U
Environmental
Audio, general
Processing Delay Less than 2.8 max ms 48 channels, stage input through LR bus to
(latency) stage output
Dynamic Range 108 min dB Analog stage input to analog stage output,
re +24 dBu, A-weighted, 20 Hz 20 kHz BW
All measurements at Fs=48 kHz with 150 Ohm source impedance and 600 Ohm load impedance, unless otherwise specified.
0 dBU = 0.775Vrms.
Type XLR3-F
Format AES/EBU
Termination 75 Ohm
16 FOH Rack
Com Input (XLR/TRS)
FOH Outputs
Type XLR3-M
Format AES/EBU
Dithering None
Dithering No
Headphone Output
18 FOH Rack
Appendix A: Compliance Information
10) Protect power cords from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the equipment.
Avid is authorized to apply the CE (Conformit Europnne) mark on this compliant
equipment thereby declaring conformity to EMC Directive 2004/108/EC and Low 11) Only use attachments/accessories specified by the manufacturer.
Voltage Directive 2006/95/EC.
20 FOH Rack
Avid Technical Support (USA) Product Information
2001 Junipero Serra Boulevard Visit the Online Support Center at For company and product information,
Daly City, CA 94014-3886 USA www.avid.com/support visit us on the web at www.avid.com