Gasolinene Generators LT2000 LT7500 20090000
Gasolinene Generators LT2000 LT7500 20090000
Gasolinene Generators LT2000 LT7500 20090000
GASOLINE GENERATOR
PART 1 INTRODUCTION
PART 2 GENERAL DESCRIPTION AND PURPOSE
PART 3 SAFETY LABELS
PART 4 SAFETY
PART 5 INSPECTION BEFORE WORK
PART 6 START
PART 7 MAINTENANCE
PART 8 TRANSPORTATION / STORAGE
PART 9 POTENTIAL PROBLEMS AND CORRECT THEM
PART 10 TECHNICAL SPECIFICATIONS
PART 11 WARRANTY
PART 1 INTRODUCTION
Thank you for choosing our Gas Generator. Our company always strives to meet the
needs of their clients and believe that you will be satisfied with our products!
For proper and safe handling of gasoline generator, as well as its maintenance and
service, please use it before you read carefully and be familiar with these instructions. If
you miss this may lead to cause injury, damage to machinery and / or environmental
contamination, in which case our company is not liable for damages incurred.
This guide introduces the information available based on current work. We reserve the
right to make changes at any time. Unable to reproduce the information without the written
permission of the company. This manual is an integral part of the cultivator. We pay special
attention to the following warnings.
Warning: Failure to comply with the instructions for operation and maintenance of
generator set in this manual may damage the generator and cause injury to people
exploiting it.
If you are experiencing difficulties please contact us, our dealers or repairers for further
clarification.
2
1. Tank 2. Muffler 3. Output Ground 4. Power input
3
2.2 Purpose: gasoline generators maintain the efficiency of electrical appliances,
equipment and machinery in places where no established grid, as in the case of
interruption or diversion of power from the standard values. Generators convert the
combustion of fuel heat into electricity. Generators of this type are characterized by low
weight and dimensions, greatly reduced noise, high efficiency, minimum fuel consumption,
durability, trouble-free operation and easy maintenance. Generators of standard frame
construction and regulation are intended for severe operating conditions.
These signs warn you of potential hazards that can lead to serious accidents.
Plates and read this guide carefully.
If you drop a plate or hard to read, contact us or our dealer for replacement.
Petrol generator is designed to ensure safety when operating and servicing if you are
working in accordance with this Instruction. Read and make sure you understand the
operating manual before operating. The generator must be used and operated by persons
over 18 years, trained to work with him and briefed in advance for safety and health at
work.
DANGER: Do not operate gasoline generators indoors. Security Ensure good ventilation
because of the danger of poisoning by exhaust gases.
6
PART 4 SAFETY
Caution: For your safety and the safety of others please pay special attention to the
precautions listed below:
Duties of operator:
Keep the generator in good condition. Dealing with the machine when it is in poor
condition can lead to serious damage and injuries;
Before use, make sure that all safety devices are well placed and will provide reliable
operation;
Make sure you are aware of the management and the most you are able to stop the
generator during an emergency;
Do not allow children or other persons who are not familiar with the operating instructions
to handle the generator;
Your clothes should be comfortable to work and prevent grip from rotating parts;
Be careful! Using the generator when you're tired, sick or after using alcohol or other
substances affecting attention and mind can lead to serious consequences;
Do not allow people or animals in the area of the generator;
To prevent short circuits or electrical shock not touch the generator if elements moistened
with wet hands. Not allow the generator to operate in areas directly exposed to rain, snow
or water jets. In use, the generator must be grounded by a cable.
7
Danger of poisoning by exhaust gases:
Exhaust gases contain carbon monoxide which is colorless and odorless and is highly
toxic. Inhalation leads to rapid loss of consciousness and death. Do not operate
generators in enclosed spaces without proper ventilation!
Make sure the oil level reaches the MAX mark on the dipstick.
If the oil level is low, add oil until the level MAX.
Place the oil dipstick, tighten it and serve the stopper of the oil filter.
Use high quality engine oils, suitable for four-stroke engines, category SG, SF, such as
Shell, Castrol and others.
Warning: The use of poor quality oils shortens engine life. Oils of Shell and Castrol is
recommended for use in any temperature.
2. Fuel level. This generator is certified to work with gasoline. Do not use unapproved
petrol do not mix gasoline with oil, do not modify to work with alternative fuels. This will
damage the components of the generator and VOID warranty. To check the fuel level:
8
Remove the filler cap. Check fuel level
1. Remove the ring and remove the air filter lid or unscrew the nuts and remove the lid.
2. Remove the nut and the clamp and release the filter element
9
PART 6 Motor Generator
1. Disconnect all loads from the generator and close the switch.
2. Turn the tap on fuel.
3. Open the choke
10
2. When working with generator:
Do not run two or more apparatus simultaneously, and one by one; If the generator will
power more than one consumer, turn them one by one, starting from the most powerful;
After starting the engine, you need to leave a minimum 3 min work excluding consumer
thereto;
Ensure that any electrical appliance is working properly before you connect it to the
generator. If the generator starts to not work in normal mode / run slowly or stop / turn right
startup key generator. Then disconnect the generator and try to understand the cause of
abnormal operation. If the circuit is overloaded and the fuse is excluded, adjusted
consumption of the circuit and wait a few minutes before you start working again. If an
indication of the voltmeter shows a larger value, stop the machine. The generator works
correctly with an indication of the voltmeter on the dashboard 230 V + / - 10% / 50 Hz /.
Do not use both devices for direct and alternating current. DC power can be used only to
charge 12 volt batteries. Do not change the places of power cables on the battery when
charging it with the generator - it can cause serious damage to the generator or battery.
When connecting the generator to an appliance in your home, consult an electrician.
Improper connection of equipment to the generator can result in damage to the generator
or appliance and / or fire.
NOTE: If the generator must be connected to the network of power supply turn off the
main electrical switch. Otherwise, the sudden release of the current network can cause
damage to the generator, electrical or cause a fire.
NOTE: If you need a sudden stop of the generator, turn the key generator!
11
SECTION 7 MAINTENANCE OF GENERATORS
The purpose of maintenance is to provide the best working condition of the generator.
Inspections and servicing at are given in the table below.
Warning: Turn off the engine before performing maintenance. If the engine has to work, it
is necessary to make sure that safe evacuation of the gases. The exhaust gases contain
poisonous gas - carbon monoxide and are dangerous to your health.
CAUTION: Use only original parts or their equivalents. Use of substandard and non parts
can cause damage to the generator.
Engine oil
level check
change
Air filter
check air filter cleaning
(1)
Court of oil - cleaning
Oil Filter - Cleaning
spark plugs
Shoe-regulation
Check valve adjustment
12
Comments:
(1) more frequent service, when used in contaminated areas;
(2) these types of services performed in authorized repairers who have specialized
equipment. See the list of representatives or the celebration of the warranty.
Engine Maintenance
Check oil level before each use or every 8 hours.
Change oil after first 5-8 hours work. Change the oil while the engine is warm. Fill
recommended oil grade.
Check spark plug yearly or every 100 hours.
Clean air filter.
Keep the engine and machine cleaner.
Check engine and machine for loose nuts and bolts and tighten them if necessary.
Oil change
Change oil when the engine is warm, to ensure rapid and complete draining of the oil:
Note: Please avoid the use of motor oil in a manner not compatible with the environment.
Collect the spent motor oil in a container and transmit your service for recycling. Do not
throw in the dirt and do not pour motor oil in the ground.
Service air filter.
Dirty air filter restricts airflow to the carburetor. To prevent the carburetor from malfunction
periodically clean the air filter. When working in a dirty environment cleaning is done more
often - 10 working hours.
13
CAUTION: Never operate the engine without air filter. The result is rapid engine wear.
Warning: Never use gasoline to wash or other flammable liquids. As a result you can get
ignition or explosion.
Service fuel filter.
Warning: Gasoline is highly flammable and explosive. Do not smoke or allow sparks and
burn in the work area.
Insert the tap off in gasoline (OFF) and unscrew the cap with the filter, remove and seal.
Wash them in solvent, dry them and place them carefully in reverse order. Put the new
rubber seal on the cap for the filter.
Measure the distance between the electrodes, which must be in the range of 0.7-0.8 mm.
If necessary, adjust;
14
Put the puck on the candle and then turn the hand to the cylinder head, and keep the
thread;
Tighten the tool with a half turn to compact the puck. If you use an old candle made from
one quarter to one-half turnovers.
Note: The candle should be well tight. Incorrect tight plug can lead to overheating, and
hence damage to the engine. Never use a candle with another day of heat indicated by the
factory.
Caution: When transporting the generator, place the fuel tap off (OFF) and keep it from
spilling fuel. Vapor or spilled fuel may cause fire.
When not using the generator for a long time, do the following:
a) Ensure that the storeroom is not too humid and dusty;
b) Drain the fuel;
Warning: Gasoline is very flammable and explosive. Do not smoke, burn and do not induce
sparks in the area of fuel storage.
When you tap the fuel in the closed position, unscrew and empty the petrol from the fuel
filter cup;
Replace the fuel tap in the open position (ON) and drain fuel from the tank into a suitable
container;
Turn the cup and place the filter for fuel;
Empty and other fuel from the carburetor through the plug.
Unscrew the cap of the oil filter and drain plug and empty the remaining oil in the engine.
Put drain plug back. Fill with oil to max level on the dipstick for oil.
Pull the lever to mechanically start until resistance was felt.
15
Part 9 potential problems and correct them
Reason Decision
16
PART 10 TECHNICAL SPECIFICATIONS
LT3000 LT5000
Model LT2500 LT3800 LT6500 LT7500
(LT3600) (LT5500)
air-cooled air-cooled air-cooled air-cooled air-cooled air-cooled
4-stroke, 4-stroke, 4-stroke, 4-stroke, 4-stroke, 4-stroke,
Engine OHV, single OHV, single OHV, single OHV, single OHV, single OHV, single
cylinder cylinder cylinder cylinder cylinder cylinder
Tank L 15 15 25 25 25 25
lubricatin
g system 0.6 0.6 1.1 1.4 1.4 1.4
,L
110, 120, 110, 120, 110, 120, 110, 120, 110, 120, 110, 120, 220,
AC out
220, 240, 220, 240, 220, 240, 220, 240, 220, 240, 240, 110/220,
voltage,
110/220, 110/220, 110/220, 110/220, 110/220, 120/240
V
120/240 120/240 120/240 120/240 120/240
AC Freq.,
50 60 50 60 50 60
Hz
Rated AC
power, 2.0 / 2.3 2.5 / 2.7 2.8 / 3.3 4.0 / 4.5 5.0 / 5.5 6.5 / 7.0
kW
Max AC
power, 2.2 / 2.5 2.8 / 3.0 3.1 / 3.8 4.5 / 5.0 5.5 / 6.5 7.0 / 7.5
kW
Dimensio 685x485x55 685x485x55 685x485x55
590x433x508 590x433x508 685x485x550
ns, mm 0 0 0
Weight
43.5 44.5 62 77.5 80 79.5
kg
17