1SBL161001R8010 A12 30 10 220 230v 50hz 230 240v 60hz Contactor
1SBL161001R8010 A12 30 10 220 230v 50hz 230 240v 60hz Contactor
1SBL161001R8010 A12 30 10 220 230v 50hz 230 240v 60hz Contactor
60Hz
Products Low Voltage Products and Systems Control Products Contactors Block Contactors
General Information
Extended Product Type: A12-30-10 220-230V 50Hz / 230-240V 60Hz
Product ID: 1SBL161001R8010
EAN: 3471522042804
Catalog Description: A12-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
Long Description: A12 contactors are mainly used for controlling 3-phase motors and generally for controlling
power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many oth
er applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pol
e contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main
poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks -
Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of ac
cessories is available.
Additional Information
ABB Industrial IT Suite: Control IT
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C
Close to Contactor for Storage -60 ... +80 C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C
BV Certificate: BV_2634H07559D0
Block Contactor Type: 3-Pole Contactor
CB Certificate: CB_FR_602227A
CCC Certificate: CCC_2013010304615753
CCC_2004010309130463
CSA Certificate: CSA_1041746
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Coil Consumption: Average Holding Value 50 / 60 Hz 8 VA
Average Holding Value 50 / 60 Hz 2 W
Average Pull-in Value 50 Hz 74 VA
Average Pull-in Value 60 Hz 70 VA
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
Coil Voltage Code: 80
Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm
Rigid Cable 1 ... 4 mm
Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm
Rigid Cable 1 ... 4 mm
Connecting terminals (delivered in open M 3.5 (+,-) pozidriv 2 screws with cable clamp
position) Built-in auxiliary terminals:
Connecting terminals (delivered in open M 3.5 (+,-) pozidriv 2 screws with cable clamp
position) Coils terminals:
Connecting terminals (delivered in open M 3.5 (+,-) pozidriv 2 screws with cable clamp
position) Main poles:
Conventional Free-air Thermal Current acc. to IEC 60947-4-1, Open Contactors q = 40 C 28 A
(Ith): acc. to IEC 60947-5-1, q = 40 C 16 A
Country of Origin: France (FR)
Customs Tariff Number: 85364900
Data Sheet, Technical Information: 1SBC100122C0202_Ch02
Declaration of Conformity - CE: 1SBD250801U1000
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Drop-out Voltage in %of Uc: Approximate 40 65 %
Drop-out Voltage in %of Uc: Approximate 40 65 %
E-nummer: 3227704
EAC Certificate: EAC_RU C-FR ME77 B01010
EAN: 3471522042804
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
Environmental Information: 1SBD250002E1004
GOST Certificate: GOST_POCCFRME77B07175
IIT Publishing Status: Level 0 - Information enabled
Industrial IT Certification Level: 0
Instructions and Manuals: FPTC407721P0001
Invoice Description: A12-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
LOVAG Certificate: LOVAG_FR97038
LR Certificate: LRS_9830011E4
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour
Maximum Mechanical Switching 3600 cycles per hour
Frequency:
Maximum Operating Altitude Permissible: 3000 m
Mechanical Durability: 10 million
Minimum Order Quantity: 1 piece
Minimum Switching Capacity: 17 / 5 volt per milliamp
Mounted Auxiliary Contacts 1st Stack: 1 NO, 0 NC
Mounted Auxiliary Contacts 2nd Stack: 0 NO, 0 NC
Mounting Position: Position 1 to 5 -Ambient temperature =<55C and control voltage 0.85 - 1.1 Uc, Ambient temp
erature 55 - 70C and control voltage equal to Uc, Position 6 - Ambient temperature =<55C
and control voltage 0.95 - 1.1 Uc, Ambient temperature >55C unauthorised
Number of Auxiliary Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Main Contacts NC: 0
Number of Main Contacts NO: 3
Object Classification Code: Q
Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Order Multiple: 1 piece
Package Level 1 EAN: 3471522042804
Package Level 1 Gross Weight: 0.34 kg
Package Level 1 Height: 47 mm
Package Level 1 Length: 76 mm
Package Level 1 Units: 1 piece
Package Level 1 Width: 78 mm
Package Level 2 Units: 63 piece
Package Level 3 Units: 1220 piece
Power Loss: at Rated Operating Conditions per Pole 0.1 W
at Rated Operating Conditions per Pole 1 W
at Rated Operating Conditions per Pole 0.2 W
Product Main Type: A12
Product Name: Block Contactor
Product Name: Block Contactor
Product Net Depth: 74 mm
Product Net Height: 74 mm
Product Net Weight: 0.340 kg
Product Net Width: 44 mm
RINA Certificate: RINA_ELE128713XG001
RMRS Certificate: RMRS_0507015250
Rated Breaking Capacity AC-3 acc. to IEC 8 x Ie AC-3
60947-4-1:
Rated Breaking Capacity acc. to IEC 10 x Ie AC-15
60947-5-1:
Rated Control Circuit Voltage (Uc): 50 Hz 220 230 V
60 Hz 230 240 V
Rated Frequency (f): Supply Circuit 50 Hz
Supply Circuit 60 Hz
Rated Frequency Limits: 25 400 Hz
Rated Impulse Withstand Voltage (Uimp): 8 kV
Rated Insulation Voltage (U):
i acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Making Capacity AC-3 acc. to IEC 10 x Ie AC-3
60947-4-1:
Rated Making Capacity acc. to IEC 60947- 10 x Ie AC-15
5-1:
Rated Operational Current AC-1 (Ie): (690 V) 40 C 27 A
(690 V) 55 C 25 A
(690 V) 70 C 20 A
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(380 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 C 12 A
(380 / 400 V) 55 C 12 A
(415 V) 55 C 12 A
(440 V) 55 C 12 A
(500 V) 55 C 12 A
(690 V) 55 C 9 A
Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A
(24 V) 6 / 144 A
(250 V) 0.55 / 138 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 3 kW
(380 / 400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Rated Operational Power AC-6b (Pe): (690 V) 70 C, 50 / 60 Hz 16.5 kvar
(690 V) 55 C, 50 / 60 Hz 19 kvar
(690 V) 40 C, 50 / 60 Hz 19 kvar
(500 / 550 V) 70 C, 50 / 60 Hz 12 kvar
(500 / 550 V) 55 C, 50 / 60 Hz 14 kvar
(500 / 550 V), 40 C, 50 / 60 Hz 14 kvar
(440 V) 70 C, 50 / 60 Hz 10.5 kvar
(440 V) 55 C, 50 / 60 Hz 12 kvar
(440 V) 40 C, 50 / 60 Hz 12 kvar
(400 / 415 V) 70 C, 50 / 60 Hz 9.5 kvar
(400 / 415 V) 55 C, 50 / 60 Hz 11 kvar
(400 / 415 V) 55 C, 50 / 60 Hz 11 kvar
(400 / 415 V) 40 C, 50 / 60 Hz 11 kvar
(230 / 240 V) 70 C, 50 / 60 Hz 6 kvar
(230 / 240 V) 55 C, 50 / 60 Hz 7 kvar
(230 / 240 V) 40 C, 50 / 60 Hz 7 kvar
Rated Operational Voltage: Main Circuit 690 V
Rated Short-time Withstand Current (Icw): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 28 A
at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
for 0.1 s 140 A
for 1 s 100 A
Resistance to Shock acc. to IEC 60068-2- Shock Direction: A 20 g
27: Closed, Shock Direction: B1 10 g
Open, Shock Direction: B1 5 g
Shock Direction: B2 15 g
Shock Direction: C1 20 g
Shock Direction: C2 20 g
RoHS Date: 20060401
RoHS Information: 1SBD350050R1000
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
Selling Unit of Measure: piece
Short Description: A12-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 32 A
Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standard
s EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to I
EC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Terminal Type: Screw Terminals
UL Certificate: UL_20160205-E312527-10-2
UL Listing Card: UL_E312527
UNSPSC: 39121529
DNV GL Certificate: DNV-GL_TAE00000TX