1 S1 en
1 S1 en
1 S1 en
4 (en)
VENTILATION GRILLES
OAH, OAV, OAB, OAK, OAN, OAS, OAM,OCM, PCR, ORP,
PTR, CCH, CCV, NRA,NRB, NRE,NRK
7
VENTILATION GRILLES
TABLE OF CONTENTS
Aluminium grilles..........................................................................................................................................................................3
Special grilles...............................................................................................................................................................................6
Fan coil grilles...............................................................................................................................................................................7
Steel grilles...................................................................................................................................................................................8
Linear grilles.................................................................................................................................................................................9
Dampers.........................................................................................................................................................................12
Ordering key................................................................................................................................................................................13
Installation instructions...............................................................................................................................................................14
Plenum boxes.............................................................................................................................................................................17
Effective discharge areas............................................................................................................................................................20
Selection diagrams.....................................................................................................................................................................23
Definition of symbols
V (m3/h) - Air flow
vef (m/s) - Effective air velocity
vL (m/s) - Maximum air velocity on a distance L
B x H (mm) - Standard grille dimensions
Aef (m2) - Effective discharge area
h (m) - Vertical distance from grille to ceiling
D (m) - Horizontal distance between two grilles
L (m) - Air throw
i - Air induction
tz (C) - Supply air temperature
tp (C) - Room air temperature
tL (C) - Core temperature on a distance L
tz (C) - (tz - tp )
tL (C) - (tL - tp )
b0,2 (m) - Jet width - distance between jet core and point where velocity equals 0,2 m/s
yt (m) - Air jet deflection
() - Jet dissipation angle
() - Blade angle
LWA (dB(A)) - Sound power level
p (Pa) - Pressure drop
Discharge scheme
m
2
m
=1
V 2
tL vL tz V vef
L
DISCHARGE WITH COANDA EFFECT
2
=2 D 2 L1 za
b
V 2
D 1 L1 za
tz V vef tL vL
L
FREE DISCHARGE
8
Design changes reserved
VENTILATION GRILLES
5 ALUMINIUM GRILLES
22,5 OAH 1
(H-25)/(B-25)
frame and blades made out of anodized
aluminium profiles
20
one row of horizontal individually adjustable
blades
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in wall
26
5
OAH 2
40
frame and blades made out of anodized
(H-25)/(B-25)
aluminium profiles
20
wall
22,5 OAV 1
(H-25)/(B-25)
OAV 2
40
frame and blades made out of anodized
(H-25)/(B-25)
aluminium profiles
front row of vertical individually adjustable
20
blades
back row of horizontal individually adjustable
blades
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in
wall
26
*Options pg. 13
**Installation pg. 14
***Standard dimensions pg. 6
9
Design changes reserved
VENTILATION GRILLES
(H-25)/(B-25)
frame and blades made out of anodized
aluminium profiles
12,5
one row of horizontal fixed blades
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in
wall
26 5
40
OAB 2-0
(H-25)/(B-25)
22,5
OAB 1-15
(H-25)/(B-25)
aluminium profiles
one row of horizontal fixed blades
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in wall
26
40 OAB 2-15
(H-25)/(B-25)
*Options pg. 13
**Installation pg. 14
***Standard dimensions pg. 6
10
Design changes reserved
VENTILATION GRILLES
22,5 OAK
(H-25)/(B-25)
frame made out of anodized aluminium
profiles
16,7
fixed plastic rectangular mesh
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in
wall
26
5
40
OAN
(H-25)/(B-25)
OAS
(H-25)/(B-25)
40 aluminium profiles
one row of horizontal fixed blades
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in
wall
26
35
7
OAS - R
(x)
(s) *Options pg. 13
**Installation pg. 14
***Standard dimensions pg. 6
11
Design changes reserved
VENTILATION GRILLES
SPECIAL GRILLE 5
OAM
(H-25)/(B-25)
fixing with visible screws (wall and ceiling)
fixing without visible screws (UR) only in
wall
26
5
OCM
19
(H-25)/(B-25)
51
PCR
H - 23
12
*B>H
*Options pg. 13
**Installation pg. 14
12
Design changes reserved
VENTILATION GRILLES
FAN-COIL GRILLE
ORP
Fan-coil unit
PTR grille
ORP grille
*Options pg. 13
**Installation pg. 14
13
Design changes reserved
VENTILATION GRILLES
T
STEEL GRILLES FOR ROUND DUCT
D
CCH 1
(H-10)/(B-10)
frame and blades made out of galvanized
H1/B1
steel
fixing with screws
20
installation on round duct
D
CCH 2
D
CCV 1
steel
fixing with screws
20
installation on round duct
D CCV 2
blades
H1/B1
14
Design changes reserved
VENTILATION GRILLES
LINEAR GRILLES
OAV, OAB
for width more than 1225mm
Linear grille (B > 1225mm) fixing with screws
standard sizes H: 75, 125, 225, 325
B+27 = B1+52
Options
installation subframe
flow damper
plenum box
B
installation subframe and damper made from
multiple parts
K S K
B1 = (B - 25) = 2K + n S
B + 27 = B1 + 52
H+27=H1+52
K S K
B1=B-25=2K + n S
15
Design changes reserved
VENTILATION GRILLES
FLOOR GRILLES
NRA 0
(H+27)/(B+27)
12.5 5.5
22
53
(H-25)/(B-25)
H/B
NRA 15
(H+27)/(B+27)
12.5 5.5
22
53
*B>H
16
Design changes reserved
VENTILATION GRILLES
NRB
NRB
okvir i lamele
frame od eloksiranog
aluminijski
and blades made aluminija
eloksirani
out profili
of anodized
jedan red horizontalnih
aluminium profiles nepominih lamela
uloak reetke
one row rastavljiv
of fixed od okvira
horizontal blades
ugradnja u pod detachable from the frame
blade insert
fixing in floor
22
*B>H
(H-25)/( B-25) 53
H/B
NRE
NRE
okvir framei lamele od eloksiranog
aluminijski
and blades outaluminija
madeeloksirani profili
of anodized
jedan red horizontalnih
aluminium profiles nepominih lamela
one row
uloak of fixed
reetke horizontal
rastavljiv blades
od okvira
blade insert
ugradnja u poddetachable
visine 33mm from the frame
fixing in floor (height 33mm)
*B>H
33
53
(H-25)/( B-25)
H/B
NRK
NRK
lamele
frameodand
eloksiranog aluminija
blades made out of anodized
jedan red horizontalnih
aluminium profiles rolo lamela
uloak reetke odvojiv
one row of fixed od okvirablades
horizontal
ugradnja u pod
blade insert detachable from the frame
standardne irine: 254, 344, 444 mm,
fixing in floor
ostale irine na upit 254, 344, 444mm, other
standard widths:
maksimalna
widths on duljina
specialreetke,
demand5m
maximum grille length, 5m
(H+27)/(B+27)
13 5,5
22
53
(H-25)/( B-25)
BL
17
Design changes reserved
VENTILATION GRILLES
DAMPERS
L - leptirasta
damper zaklopka
43
43
83
66
40
23
K - kanalska
damper zaklopka
350
350
390
373
40
23
VK
VK - kanalska
damper zaklopka
90
130
90
113
40
23
SS -- iber
damperzaklopka
5
5
45
40
28
23
18
Design changes reserved
VENTILATION GRILLES
ORDERING KEY
OPTIONS
GRILLE Damper
Removable filter
Installation with
Plenum box
subframe
RAL...
insert
L K VK S
OAH
OAV
OAB
OAS
OAS-R
OAK
OAN
OAM
OCM
CCH
CCV
NRA
NRB
NRE
NRK
PCR
ORP
PTR
Ordering key:
19
Design changes reserved
VENTILATION GRILLES
INSTALLATION INSTRUCTIONS
Wall installation
H+27=H1+52
H+27=H1+52
H-10
H1
H1
H
Subframe installation
HxB
Ceiling installation
20
Design changes reserved
VENTILATION GRILLES
T
Installation CCV, CCH
26
B-10
L-10 Note: make sure that the grille height H fits for
H-10 x L -10
installation on a round duct with diameter D
H1 x L1
H x L
H-10
D
20
D
B H T D B H T D B H T D
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
225 x 75 150 225 x 125 300 225 x 225 600
325 x 75 325 x 125 325 x 225
425 x 75 425 x 125 425 x 225
525 x 75 40 525 x 125 45 525 x 225 55
625 x 75 625 x 125 625 x 225
825 x 75 825 x 125 825 x 225
1125 x 75 400 1125 x 125 900 1125 x 225 2400
ORP installation
B H
A
37
ceiling and then the bracelets suspension are
fixed to the inner side of the ceiling.
B-25 26 H-25 26
5
B+27
Detail
Detalj AA
M6
21
Design changes reserved
VENTILATION GRILLES
B+32
B+32 H+32
22
22
53
H-25
53
B-21
H-21
B H
NRE installation
Ugradnja podne reetke NRE
ploe
Cut anseopening
i ree otvor dimen
in the floorije:
board with
Floor
Podnaboard
ploa dimensions:
(B+1) x (H+1)
a donjoj strani ploe, vij ima se privrste nosivi
Fix theelini
po inani L steel beam
kutni i onto
3 3a lower side
na koje se of the
polae
opening
H+100
D D
C C reetkaGrille is not for external installation
H
ijeNota intended
vanjsku ugradnju
for loads higher than one
ijepersons
namjenjena
weighta nosivosti ve e od teine
osoFore floor heights above 40mm, a compen-
a staionvisinu poda
latice4of mm
10mm dodaje se kompen a ijska
is added
letvi
a visine mm
L steel beam and compensation latice are
B
notisupplied
kutnik kompen awith grille
ijska letvi a nisu predmet
isporuke
Cross section
Presjek C C-C
-C Cross section
Presjek D - DD-D
B
30
30
40
10
LKutnik 30x30
steel beam Compensation latice
Kompenzacijska
letvica
22
Design changes reserved
VENTILATION GRILLES
60
D1
D
1
(H)*/(H-10)**
(B)*/(B-10)**
110
60
B/2
D1
D D
1 1
(B)*/(B-10)** (H)*/(H-10)**
110
PK1 / PK1-UR PK1 / PK1-UR
B H D Number of h1 B H D Number of h1
mm mm mm connections mm mm mm mm connections mm
225 125 158 1 300 425 325 158 1 300
325 125 198 1 340 525 325 198 1 340
425 125 198 1 340 625 325 198 1 340
525 125 248 1 390 825 325 248 2 390
625 125 248 1 390 1025 325 248 2 390
825 125 248 2 390 1225 325 248 2 390
1025 125 248 2 390 525 425 248 1 390
1225 125 248 2 390 625 425 248 1 390
325 225 248 1 390 825 425 248 2 390
425 225 298 1 440 1025 425 298 2 440
525 225 298 1 440 1225 425 298 2 440
625 225 313 1 455 625 525 313 1 455
825 225 298 2 440 825 525 298 2 440
1025 225 298 2 440 1025 525 298 2 440
1225 225 298 2 440 1225 525 298 2 440
Ordering key:
23
Design changes reserved
VENTILATION GRILLES
(B)*/(B-10)** (H)*/(H-10)**
D D
50
h1
(B)*/(B-10)** (H)*/(H-10)**
Ordering key:
24
Design changes reserved
VENTILATION GRILLES
h 1
(B)*/(B-10)** (H)*/(H-10)**
Ordering key:
25
Design changes reserved
VENTILATION GRILLES
OAB, NRA
HB 225 325 425 525 625 825 1025 1225
75 0,0060 0,0090 0,0110 0,0140 0,0170 0,0220 0,0280 0,0340
525 - - - - - - - -
OCM
HB 225 325 425 525 625 825 1025 1225
75
125 0,0085 0,0128 0,0170 0,0213 0,0255 0,0340 0,0425 0,0510
OAM
HB 225 325 425 525 625 825 1025 1225
75
125 0,0033 0,0050 0,0067 0,0083 0,0100 0,0133 0,0166 0,0200
PTR
HB 225 325 425 525 625 825 1025 1225
75 0,0070 0,0100 0,0140 0,0170 0,0210 0,0260 0,0340 0,0390
26
Design changes reserved
VENTILATION GRILLES
OAB, NRA
HB 225 325 425 525 625 825 1025 1225
75 0,006 0,009 0,011 0,014 0,016 0,022 0,028 0,033
OAK
HB 225 325 425 525 625 825 1025 1225
75
125 0,012 0,018 0,025 0,031 0,038 0,050 0,063 0,075
OAN
HB 225 325 425 525 625 825 1025 1225
75 - - - - - - - -
27
Design changes reserved
VENTILATION GRILLES
OCM
HB 225 325 425 525 625 825 1025 1225
75 - - - - - - - -
PCR
HB 225 325 425 525 625 825 1025 1225
75 - - - - - - - -
OAS
HB 225 325 425 525 625 825 1025 1225
75 0,0040 0,0059 0,0079 0,0099 0,0119 0,0158 0,0199 0,0239
ORP
B [mm] 500 600 700 800 900 1000 1100 1200
28
Design changes reserved
VENTILATION GRILLES
SELECTION DIAGRAMS
1.1 Selection diagrams for supply air grilles: OAH, OAV, CCH, CCV
h(m) 0
H B 0,2
525 1025 1225
125 225 325 425 525 625 825 1025 1225 0,8
0,5
0,4
10
9 0,3
8
7
/s)
100
(m
6 0
V
L
5
500
400
4
3 300 3 /h)
V(m
2 200
150
1,5
v
ef [m 1 100
/s]
L=8m vef
3
0,75
V = 1000 m3/h vef = 2,2 m/s; tL =0,68 K;
4
tZ = 4K
0,5
h = 0,9 m From 1.3 : y = k * tz = 3,4 m
0,4 Sound power level
7
10
20
30
40
0,3
Correction: 24+1 = 25 dB(A); D> 0,2 L > 1,6m
i
1.3 Air pressure drop and sound power level OAH, OAV, CCH, CCV
- with L damper
op r
- with K, VK damper
% pe
en
25 dam
150 150
L
/s]
12 [m
50
100 100 /s ] 60
10 [m
55
50 /s]
8 [m
0%
50
50
10
45 40 45
/s]
))
(A
/s]
[m
6 [m
B
WA (d
30 40 40
k
v
/s]
20 5 [m
L
p Pa]
35
20 35 4 [m
/s]
30 %
% 50% 25
p Pa]
10 3 [m
/ s] 100
30
10 6
25
4
vef (m/s)
20 2
5
1
4
1 1,5 2 3 4 5 6 7 8
vef (m/s)
29
Design changes reserved
VENTILATION GRILLES
1.4 Selection diagrams for exhaust air grilles: OAB, NRA, NRB, NRE, NRK
0
0,2
H B
0,4
425 625 825 1025 1225
325 425 525 625 825 1025 1225 0,6
225
h [m]
325 425 525 625 825 1025 1225 0,8
125 225 325 425 525 625 825 1025 1225 1,0
3 4 5 6 7 8 9 10 15 20
75 225 325 425 525 625 825 1025 1225
L[m]
40
00 10 3 4 5 6 7 8 9 10 15 20
30
00 8
20 6
00 5
15 1
00
4
10
00
9
80 00 0,75
70 0
3
60 0
50 0
0
40 0,5
0
30 2
0 0,4
9 10
1,5 0,3
7 8
1
6
80
0
50
0
40
5
0
30
/h]
4
m
0
V[
3
20
0
2
15
0
1,5
ve 10
f [m 0
/s]
1
vef
3
0,75
V = 1000 m3/h vef = 2 m/s; tL =0,68 K;
4
0,5
h = 0,9 m From 1.3 : y = k * tz = 3,4 m
0,4 Sound power level
7
10
20
30
40
1.6 Air pressure drop and sound power level OAB, NRA, NRB, NRE, NRK
- with L damper
op r
- with K, VK damper
% pe
en
25 dam
150 150
L
/s]
12 [m
50
50
50
10
45 40 45
/s]
))
(A
/s]
[m
6 [m
B
WA (d
30 40 40
k
v
]
20 5 [m/s
L
p Pa]
35
20 35 4 [m
/s]
30 %
% 50% 25
p Pa]
10 3 [m
/s] 100
30
10 6
25
4
vef (m/s)
20 2
5
1
4
1 1,5 2 3 4 5 6 7 8
vef (m/s)
30
Design changes reserved
VENTILATION GRILLES
1.7 Selection diagrams for supply air grilles: OAB, NRA, NRB, NRE, NRK
0,2
h [m]
OAB, NRA,NRK H=75 H=125 H=225 H=325 0,4
0,6
OAV, CCV,NRB H=75 H=125 H=225 H=325
0,8
1,0
3 4 5 6 7 8 9 10 15 20 25
L [m]
3 4 5 6 7 8 9 10 15 20 25
30
00
1,5
7
20
00 1,0
6
15
5 00 5
0,7
v ef [m/s]
10
00
0,5
3
80
0
/s]
[m
0,4 vL
50
0 /h] 0,3
2 m
V[
40
0
30
0
1,5
20
0
/s 150
1m
1.8 Induction diagram
Vef (m/s)
1 1,5 2 3 4 5 6 7 10
1,0
vL (m/s)
0,75
4
5
0,5
0,4
7
10
15
20
30
40
0,3
i
1.9 Air pressure drop and sound power level for linear grilles OAB, NRA, NRB, NRE, NRK
- with L damper
op r
- with K, VK damper
% pe
en
25 dam
150 150
L
/s]
12 [m
50
50
50
10
45 40 45
/s]
))
(A
/s]
[m
6 [m
B
WA (d
30 40 40
k
v
]
20 5 [m/s
L
p Pa]
35
20 35 4 [m
/s]
30 %
% 50% 25
p Pa]
10 3 [m
/s] 100
30
10 6
25
4
vef (m/s)
20 2
5
1
4
1 1,5 2 3 4 5 6 7 8
vef (m/s)
31
Design changes reserved
VENTILATION GRILLES
2.0 Selection
Izborni dijagram
diagrams
za odsisne
for exhaust
reetke:
air grilles:
OAH, OAH,
OAV, OAV,
CCH, CCH,
CCV, CCV,
OAB, OAB,
OAN, OAN,
NRA, NRA,
NRB, NRB,
NRE, NRE,
NRK NRK
0,4
1
0,35
0,3
0,2
0,1
1,5
0,05
0,04
2
)
A ef(m
0,03
2
0,02
vef (m/s)
0,01
0,007
3
0,005
4
20
8
9
10
00
50
200
00
100
0
500
0
400
0
300
3
/h) Zadano:
Given: Solution
Rjeenje
V(m
0
200
Str. 19
Pg.
100
Aef = 0,095
0,095mm22;;
Grille
Tip reetke:
type: OAB Dijagram
Diagram 2.02.0::
500
OAB 1-0/L
1-0/L vef=5,85 m/s
400
(otvoreno
(open 100%):
100%):
p =12 Pa
2.1 Dijagram pada
Air pressure tlaka
drop andi razine
soundzvune
power snage
level
-with L damper - with K, VK damper
%
10 %
0%
25
50
%
25
100 100
45
%
50
50 50
40
p Pa)
p Pa)
40 40
50
30 35 30
0%
25
C
25
WN
L
10
20 30 45 20
15
15 25 40
10
10 20 35
) )
(A
B
(d
30 5
A
W
L
5 25 4
4 1 1,5 2 3 4 5 6 7 8
1 1,5 2 3 4 5 6 7 8
vef (m/s)
vef (m/s)
32
Design changes reserved
VENTILATION GRILLES
2.2 Izborni
Selection
dijagram
diagram
zafor
PTRPTR
reetke
grille za dovod zraka
0
H B
0,2
525 1025 1225
H L
0,4
425
5 2 5
625 825 1025 1225
1 0 2 5 1 2 2 5
325
4 2 5 425 525 625 825
6 2 5 1025
8 2 51225 1 0 2 5 1 2 2 5 h 0,6
[m ]
3 2 5 4 2 5 5 2 5 6 2 5 8 2 5 1 0 2 5 1 2 2 5 0,8
225 325 425 525 625 825 1025 1225
2 2 5 3 2 5 4 2 5 5 2 5 6 2 5 8 2 5 1 0 2 5 1 2 2 5
125 225 325 425 525 625 825 1025 1225 1,0
1 2 5 2 2 5 3 2 5 4 2 5 5 2 5 6 2 5 8 2 5 1 0 2 5 1 2 2 5 3 4 5 6 7 8 9 10 15 20
75
7 5 2 2 225
5 3 325
2 5 4 425
2 5 525
5 2 5 625
6 2 5 8825
2 5 1025
1 0 2 1225
5 1 2 2 5 L [m]
40
00 10 3 4 5 6 7 8 9 10 15 20
30 9
00 8
7
20 6
00 5 1
15
00 4
10 3
00 0,75
2
0,5
1,5 0,4
10
9 0,3
1
8 15 0,25
0 0
7
0,2
10
6 0
80 900 0
70 0
5 0 0,15
60
0
50
0
4 40 450
35 0
0
3 30
25 0
0
/h]
2 20 m
0 V[
1,5 15
0
ve [
f m
/s] 1 10
0
2.3 Dijagram
Air pressure
padadrop
tlaka
and
i razine
soundzvune
power snage
level for
zaPTR
PTRgrille
reetke
withsaL-damper
L-zaklopkom
op er
% mp
en
25 L da
150
%
50
100
45
0%
50
10
50
40
40 45
p ( Pa )
30 35
40
25
Otvorenost L zaklopke
N C
30
W
20
L
35
A)
15
25
(
dB
30
A
10
L
W
20
25
20
5
4
1 1,5 2 3 4 5 6 7 8
vef ( m / s )
33
Design changes reserved
VENTILATION GRILLES
05
07
10
13
0,0 7
15
18
45
21
0,0 1
23
35
55
66
4
0,0 6
29
94
1
0,0
0,0
0,0
84 0,07
2
0,0
0,0
0,0
0,0
0,0
0,0
0,0
0,0
0,0
0,0
0,0
100
90
13
0,0
80
0, 1
02
0,1
70
60
39
27
0,1
0,1
50
59
43
40
0,1
0,1
p [Pa]
30
25
76
0,1
f =
20
Ae
15
10
9
8
7
6
2
1 000
2 000
3 000
4 000
100
700
600
800
500
900
200
300
400
V [m3/h]
34
Design changes reserved
VENTILATION GRILLES
Dijagram of
2.5 Diagram razine zvune
sound powersnage
level za
forORP
ORPreetke
grille
100
50
40
00
x3
00
00
00
00
LWA dB(A)
x4
x7
x5
30
10 0 x 0
x 1 100
x6
12 0 x 00
11 x 1 0
90 80
0
00 90
0
30
20
0
0
0 0
40
00 1
70
50
x
60
0
80
20
10
0,5
100 200 300 400 500 1000 1500 2500 5000 10 000
3
V (m/h)
LS -13 -10 -7 -3 0 3 6
LWA dB [A] - ound po er level on grille e
= 0,1)
LWA d = LWA 0,1 m2 + L
L [dB] - ound po er orre tion e
= 1 m 2)
zraun pada
Pressure tlakaorzagrilles
drop reetket koje nisu
at are notnavedene u dijagramima
mentioned in diagramsO a ove
O Oi O O and O
O O p = 1 ve 2
O p = 2 ve 2
35
Design changes reserved
VENTILATION GRILLES
2.6 Jet width diagram b0,2 (for h>0,8m) 2.6a Jet deflection because of tz
[m/s]
L
v L
heating
grijanje
y
b 02 [mm]
1,0
cooling
la enje
0,5
y = k * tz
2 4 6 8 10 12 14 16 18 20
Domet mlaza L [ m ]
2.7 Discharge with Coanda effect 2.8 Discharge without Coanda effect
0,50 15
4(
3,5 m/
0,30 s)
10 3( (m
m/ /s)
0,20 8 s)
2,5
0,15 (m
/s)
6 2( /s)
2 (m
0,10 m/
/s)
s)
3 (m
5
/s)
1,5
4 (m
/s)
5 (m
4
tz
0,06 (m
/s)
/s)
Aef (m2)
6 (m
/s)
/s)
0,04 3
7 (m
v
9 (m (m/s)
f m
ef (m
ve (
/s)
/s)
8
1(
)
m /s
0,02 2 m/
(
10
s)
0,01
1
0,005 0,01 0,02 0,05 0,10 0,20 0,50
0,005
Aef (m2)
1,00
15
0,60
(m
)
0,40
0,30
10 (m )
(m )
9 m
0,20
)
8( )
0,10
7(
m
6(
m)
0,08
5(
m)
k
L(
4(
0,06
m)
m)
3(
m)
0,04
0,03
0,02
0,01
36
Design changes reserved
VENTILATION GRILLES
NOTES:
37
Design changes reserved