Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Abt-Ccp154-Tis 2013-03

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28
At a glance
Powered by AI
The document discusses the setup required to prepare for a course on programming with Structured Text and Sequential Function Charts in Studio 5000 Logix Designer. It covers topics like software, hardware, and workstation requirements.

The document discusses general setup, ordering checklists, required setup steps, controllogix workstation layout, software workstation setup, and introduction to job aids that are used.

Software required includes Studio 5000, RSLinx Classic, RSLogix Emulate 5000, and FactoryTalk View ME Station. More details are provided in the General Setup section.

Setup Information

Studio 5000t Logix Designer


Level 4: Structured
Text/Sequential Function Chart
Programming
Table of Contents

General Setup: Structured Text/Sequential Function Chart Programming . . . . . . . . 1


Exercise Setup: Programming Assignments, Expressions and Instructions in Structured Text
within a Logix Designer Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Exercise Setup: Programming Constructs and Comments in Structured Text within a Logix
Designer Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Exercise Setup: Designing a Sequential Function Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Exercise Setup: Programming a Sequential Function Chart in a Logix Designer Project . . . . . . . . . . . 15
Exercise Setup: Testing a Sequential Function Chart in a Logix Designer Project . . . . . . . . . . . . . . . . 17
Exercise Setup: Storing and Resetting Sequential Function Chart Data in a Logix Designer Project . . . 19
Exercise Setup: Resetting and Pausing a Sequential Function Chart in a Logix Designer Project . . . . . 21
ii Table of Contents
General Setup: Structured Text/Sequential Function Chart Programming 1

General Setup: Structured


Text/Sequential Function Chart
Programming

Introduction This document contains information about the setup steps required to
prepare for course CCP154.

Several Weeks Before Use Ordering Checklist

The following equipment is required for each workstation:


If the latest versions of Studio 5000 and - A computer that meets the minimum requirements necessary
RSLinx Classic software are not on the to run all application software:
student training image, they can be
downloaded from the Rockwell Software Version
Automation Technical Support site using .Net Framework 4.0
your GoldMaster serial number.
Studio 5000 (with activation for Structured Text and
21.0
Sequential Function Charts)
Firmware files for Studio 5000 21.0
RSLinx Classic 3.51
RSLinx Enterprise 5.50 or later
RSLogix Emulate 5000 21.0
FactoryTalk View Studio for Machine Edition 6.10
FactoryTalk View Station RT 6.10
Microsoft PowerPoint or Microsoft PowerPoint
2002 or newer
Viewer

- ControlLogix workstation (Part No. ABT-TDCLX3) or


equivalent hardware (if using hardware)
- Communication cards and cables for an EtherNet/IP network
(if using hardware)

Tip " See the ControlLogix Workstation Layout section of this General
Setup document for more information and workstation configuration
details.

Tip " See the Software Workstation Setup section of this General Setup
document for more information and workstation configuration
details.

Job Aids The following job aid can be used to complete the exercises:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide
(ABT-1756-TSJ50)

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
CCP154_GeneralSetup
2 General Setup: Structured Text/Sequential Function Chart Programming

Day Before Use Required Setup

Perform the following steps for each workstation:


- Unzip the Student Exercise Files and place them on each
student PC.
- Restore Logix Designer application to its default settings by
performing the following actions:
- If it is open, close Logix Designer application.
- Press and hold the CTRL + SHIFT key combination.
- Continue holding the CTRL + SHIFT key combination and
start the software.
- Do not release the CTRL + SHIFT key combination until the
software has started.
- In Logix Designer application, set the default directory under
Tools!Options.
- In the Logix Designer default project directory, delete all old
files.
- On the desktop, make a shortcut for each software.

ControlLogix Workstation The ControlLogix workstation (or equivalent custom setup) used in
Layout the course requires the following equipment:
x 12 dual input and output pushbuttons
x 4 selector switches (on/off)
x 2 analog inputs
x 2 analog meters
x A 10-slot chassis with the modules listed in the following table:

To match the standard workstation configuration


in the exercise files, the workstations modules
must be placed in the following slots:

Slot Module Description


0 1756-OB16D Digital output module (DO0 to DO5)
1 1756-L73 (5573) ControlLogix Controller
2 1756-IB16D Digital input module (DI0 to DI15)
3 Empty slot
4 1756-OB16D Digital output module (D06 to DO11)
5 1756-CNB ControlNet bridge module
6 1756-DHRIO Data Highway/Remote I/O bridge module
7 1756-OF6VI Analog output module
8 1756-IF6I Analog input module
9 1756-ENxT EtherNet/IP bridge module

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
CCP154_GeneralSetup
General Setup: Structured Text/Sequential Function Chart Programming 3

If your workstations do not include 1756-DHRIO


modules, you should leave slot 6 empty.

The workstations modules must have firmware


compatible with Studio 5000 version 21.

Tip " Firmware files are available at:


http://support.rockwellautomation.com/ControlFlash/

The layout of the workstation is shown in the following graphic:

10-Slot ControlLogix
Chassis

12 Dual Discrete
Inputs/Outputs J5
Status

J5
Sta tus

Motion Equipment
DC Bus DC Bus

J2 J2
L1 L1

(Not Required)
100-240 100-240
L2/N VAC L2/N VAC
50/60 Hz 50/60 Hz

R R
J1 J1
S S
Motor

4 Selector
Motor
T T

Advantage Line Ad vantage Line

Switches

2 Analog Meters 2 Analog Inputs


(Potentiometers)

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
CCP154_GeneralSetup
4 General Setup: Structured Text/Sequential Function Chart Programming

The following ControlLogix workstation inputs and outputs are used


in this course:
Inputs
Outputs

DI0 DI1 DI2 DI3


Green
Pushbuttons DO0 DO3 DO6 DO9

Amber DI4 DI5 DI6


DI7
Pushbuttons DO7
DO1 DO4 DO10

DI8 DI9 DI10 DI11


Red
Pushbuttons DO2 DO5 DO8 DO11

DI12 DI13 DI14 DI15


Selector
Switches

Hardware Workstation The following workstation setup is required for all workstations:
Setup - In RSLinx Classic software, configure an EtherNet/IP driver.
- Set up an Ethernet/IP network and assign IP addresses to the
computers and EtherNet/IP modules.
- Verify the ControlLogix workstations match the standard
hardware layout found in the Workstation Layout section of
If the classroom layout does not allow this document.
easy networking through hubs and
switches, you can have students directly
connect the workstation and computer If you are using a non-standard workstation
using a crossover Ethernet cable. configuration, you will have to modify the I/O
configurations for each Student Exercise file to
match your hardware layout.

Once you have verified that communications


between the computers and ControlLogix
workstations have been established, delete all
previously created RSLinx Classic drivers.

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
CCP154_GeneralSetup
General Setup: Structured Text/Sequential Function Chart Programming 5

Software Workstation Setup and testing takes approximately 20 minutes per machine. This
Setup does not include re-imaging.
If you are familiar with ghosting, you Perform the following steps on each workstation:
may want to create a simulator image for
future classes once you have a - If any traces of SoftLogix remain on the computer, or if you are
completed and tested setup. unsure, re-image the computer. A typical uninstall will not
remove all traces of SoftLogix which will cause errors.
- Verify that you have the following software installed and
activated:
- RSLinx Classic software, version 3.51
- RSLinx Enterprise software, version 5.50 or later
- RSLogix Emulate 5000 software, version 21.0
- FactoryTalk View ME Studio software, version 6.10
- FactoryTalk View ME Station software, version 6.10
- Studio 5000 Logix Designer software, version 21 (with
activation for Structured Text and Sequential Function Charts)
- Launch RSLinx Classic software and then add a new Virtual
Backplane driver in slot 0 (default). Close the software.
- Launch RSLogix Emulate 5000 Chassis Monitor software and
create a controller in slot 3.
Tip " Do not create modules in any other slots. RSLinx will occupy slots 0
and 1 when launched.

- Open RSLinx Classic software and click RSWho to verify that


the network shows an active virtual chassis with your configured
modules.

Required Training Simulator Testing

Test the setup using the files in the Training Simulator Files folder:
- In the Logix Designer application, download the
Training _Simulator_Test_Logic_Rev_A.acd file to the
controller in the virtual chassis (slot 3).
- Change the controller to Rem Run mode.
- Double-click the CCP152_CCP154_Training_Simulator.apa
file.
- At the prompt, select Restore the FactoryTalk View Machine
Edition application: and click Next
- Keep the default name.
- You will NOT receive confirmation when it is done.
- Open FactoryTalk View Studio software and then select
CCP152_CCP154_Training_Simulator.
- In the Explorer Pane, expand RSLinx Enterprise and then
double-click Communication Setup.
- Create a short cut to the virtual controller in slot 3:
Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
CCP154_GeneralSetup
6 General Setup: Structured Text/Sequential Function Chart Programming

- Create a short cut to the virtual controller in slot 3:


- In the Device Shortcut pane, click My_Controller.
- In the Design (Local) tab, right-click 1789-A17 Backplane
and select Add Device.
- Expand 1756-Lx/Em, ControlLogix L55xx Emulator and then
select the rev 21 emulator.
- Click OK.
- Change the slot number to Slot 3.
- Click OK.
- On the Design (Local) tab, click Copy from Design to Runtime
and click Yes.
- Click OK to close the Communication setup (if you do not click
OK you will receive an error on the next step).
- From the Application menu, select Create Runtime Application.
- Keep the default name and location and click Save.
- Close FactoryTalk View ME Studio software (if you do not close
you will receive and error on the next step).
- Open FactoryTalk View ME Station software (not Studio).
- Load the CCP152_CCP154_Training_Simulator.mer runtime
file and click Yes to any prompts.
- After loading, click Run Application.
- You should see the Label Selector Screen.
- Select Default and then click Goto Simulator.
- To test the setup click various inputs; corresponding outputs will
be enabled (e.g., Input 1 will enable Output 1).

Tip " Graphics should be displayed with no wire frames or missing tags.

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
CCP154_GeneralSetup
General Setup: Structured Text/Sequential Function Chart Programming 7

During Use / Best Practices Changing Labels

Each exercise indicates which set of device labels to select:


- To change the device labels click the Goto Device Label
Selector button on the bottom of the Main Device page:
- Select your application and then click the Goto Simulator
button to return.
- A default set of labels that can be used with any exercise is
provided.

Stopping and Restarting the Simulator

Do not shut down the FactoryTalk View ME Station screen or the


RSLogix Emulate 5000 Chassis monitor between exercises:
- If you must shut down at the end of class, please do so in this
order:
- Click the Shutdown Simulator button in FactoryTalk View
ME Station.
- Go offline with the controller and then close the RSLogix
Emulate 5000 Chassis monitor.
Tip " If the RSLogix Emulate 5000 Chassis monitor gives an error
message, open the task manager ([Ctrl]+[Alt]+[Delete]) and close
the RSLogix Emulate 5000 Chassis monitor.

- To restart the software simulator, use the steps in the testing


section of this document.

Enhancing Use

The following tips may enhance your instructor setup and student
experience:
Instructor Setup:
- Consider obtaining extra thumb drives with the ghosted images to
expedite the setup

Student Experience:
- Minimize the RSLogix Emulate 5000 Chassis monitor for the
students.
- Consider one computer per person instead of sharing.
- Consider an optional second computer monitor to separate the
software simulator screen from the Logix Designer application.

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
CCP154_GeneralSetup
8 General Setup: Structured Text/Sequential Function Chart Programming

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
CCP154_GeneralSetup
Exercise Setup: Programming Assignments, Expressions and Instructions in Structured Text 9

Exercise Setup: Programming


Assignments, Expressions and
Instructions in Structured Text
within a Logix Designer Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following AIST_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix and software
workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
AISTe56r_setup
10 Exercise Setup: Programming Assignments, Expressions and Instructions in Structured Text

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
AISTe56r_setup
Exercise Setup: Programming Constructs and Comments in Structured Text 11

Exercise Setup: Programming


Constructs and Comments in
Structured Text
within a Logix Designer Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following CCST_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix and software
workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
CCSTe56r_setup
12 Exercise Setup: Programming Constructs and Comments in Structured Text

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
CCSTe56r_setup
Exercise Setup: Designing a Sequential Function Chart 13

Exercise Setup: Designing a


Sequential Function Chart

Required Hardware and N/A


Software
Exercise File N/A

Exercise Setup This is a paper-based exercise and requires no setup.

Recommended Job Aids N/A

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
DESFe56r_setup
14 Exercise Setup: Designing a Sequential Function Chart

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
DESFe56r_setup
Exercise Setup: Programming a Sequential Function Chart in a Logix Designer Project 15

Exercise Setup: Programming a


Sequential Function Chart in a
Logix Designer Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following PSFC_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix or software workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
PSFCe56r_setup
16 Exercise Setup: Programming a Sequential Function Chart in a Logix Designer Project

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
PSFCe56r_setup
Exercise Setup: Testing a Sequential Function Chart in a Logix Designer Project 17

Exercise Setup: Testing a


Sequential Function Chart in a
Logix Designer Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following TSSF_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix or software workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
TSSFe56r_setup
18 Exercise Setup: Testing a Sequential Function Chart in a Logix Designer Project

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
TSSFe56r_setup
Exercise Setup: Storing and Resetting Sequential Function Chart Data in a Logix Designer Project 19

Exercise Setup: Storing and


Resetting Sequential Function
Chart Data in a Logix Designer
Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following SRSF_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix or software workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
SRSFe56r_setup
20 Exercise Setup: Storing and Resetting Sequential Function Chart Data in a Logix Designer Project

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
SRSFe56r_setup
Exercise Setup: Resetting and Pausing a Sequential Function Chart in a Logix Designer Project 21

Exercise Setup: Resetting and


Pausing a Sequential Function
Chart in a Logix Designer Project

ControlLogix Workstation The following hardware and software is required for this exercise:
Required Hardware and x ControlLogix workstation
Software x Ethernet/IP network
x Computer with the following software installed:
- RSLinx Classic
- Studio 5000
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Software Workstation A computer with the following software installed is required for this
Required Software exercise:
x RSLinx Classic
x Studio 5000
x RSLogix Emulate 5000
x FactoryTalk View ME Station
Tip " For more detailed hardware, software, and workstation information,
see the General Setup for CCP154.

Exercise File This exercise requires the following RPSF_1756r_A1.acd project


file.

Exercise Setup A driver configured in RSLinx Classic software for communications


between the computer and the ControlLogix or software workstation.

Recommended Job Aids The following job aid is recommended for use with this exercise:
x Studio 5000 Logix Designer and Logix5000 Procedures Guide

Rev. March 2013 E 2013 Rockwell Automation, Inc. All rights reserved.
RPSFe56r_setup
22 Exercise Setup: Resetting and Pausing a Sequential Function Chart in a Logix Designer Project

E 2013 Rockwell Automation, Inc. All rights reserved. Rev. March 2013
RPSFe56r_setup
Catalog Number ABT-CCP154-TIS - March 2013 E 2013 Rockwell Automation, Inc. All rights reserved. Printed in USA
Supersedes Catalog Number ABT- CCP-154-TIS - June 2012

You might also like